scieee AI-readable full text Open interactive document viewer

A state–of–the-art review on indoor air pollution and strategies for indoor air pollution control

González Martín, Javier,Kraakman, Norbertus Joannes Richardus,Pérez, Cristina,Lebrero Fernández, Raquel,Muñoz Torre, Raúl

Abstract

Producción Científica

Full text

1 A STATE-OF-THE-ART REVIEW ON INDOOR AIR POLLUTION AND THE 1 POTENTIAL OF BIOTECHNOLOGIES FOR INDOOR AIR PURIFICATION 2 Javier González-Martína,b, Norbertus Kraakmanb,c, Cristina Pérezb, Raquel Lebreroa,b, Raúl 3 Muñoza,b*. 4 a Department of Chemical Engineering and Environmental Technology, University of 5 Valladolid, Dr. Mergelina s/n., Valladolid 47011, Spain 6 b Institute of Sustainable Processes, University of Valladolid, Dr. Mergelina s/n., Valladolid 7 47011, Spain 8 c Jacobs Engineering, Bristol, United Kingdom 9 *-Author for correspondence. E-mail address: [email protected]. Full postal address: 10 Department of Chemical Engineering and Environmental Technology, University of 11 Valladolid, Dr. Mergelina s/n., Valladolid 47011, Spain. Phone number: +34 983186424 12 Author’s email addresses: [email protected]; [email protected]; 13 [email protected]; [email protected]; [email protected]. 14 15 Abstract 16 Indoor air pollution has traditionally received less attention than outdoors pollution despite 17 indoors pollutant levels are typically twice higher, and people spend 80-90 % of their life in 18 increasing air-tight buildings. More than 5 million people die every year prematurely from 19 illnesses attributable to poor indoor air quality, which also causes multi-millionaire losses due 20 to reduced employee’s productivity, material damages and increased health system expenses. 21 Indoor air pollutants include particulate matter, biological pollutants and over 400 different 22 chemical organic and inorganic compounds, whose concentrations are governed by several 23 outdoor and indoor factors. Prevention of pollutant is not always technically feasible, so the 24 implementation of cost-effective active abatement units is required. Up to date no single 25 physical-chemical technology is capable of coping with all indoor air pollutants in a cost-26 © 2021 Elsevier. This manuscript version is made available under the CC-BY-NC-ND 4.0 2 effective manner. This problem requires the use of sequential technology configurations at the 27 expenses of superior capital and operating costs. In addition, the performance of conventional 28 physical-chemical technologies is still limited by the low concentrations, the diversity and the 29 variability of pollutants in indoor environments. In this context, biotechnologies have emerged 30 as a cost-effective and sustainable platform capable of coping with these limitations based on 31 the biocatalytic action of plants, bacteria, fungi and microalgae. Indeed, biological-based 32 purification systems can improve the energy efficiency of buildings, while providing additional 33 aesthetic and psychological benefits. This review critically assessed the state-of-the-art of the 34 indoor air pollution problem and prevention strategies, along with the recent advances in 35 physical-chemical and biological technologies for indoor pollutants abatement. 36 37 Keywords: air pollutant; biotechnology; indoor air quality; prevention strategy; physical-38 chemical technology; volatile organic compound. 39 40 Highlights: 41 • A state-of-the-art review on the global problem of poor indoor air quality 42 • Typology, sources and health risks of the most common indoor pollutants are revised 43 • Measures for prevention and abatement of indoor pollutants are carefully examined 44 • Evaluation of the performance of traditional physical-chemical methods 45 • Assessment of innovative and sustainable systems based on biotechnologies 46 3 Abbreviation list 47 AC – Activated carbon 48 BF – Biofilter 49 BTF – Biotrickling filter 50 BTEX – Benzene, toluene, ethylbenzene and xylene 51 CADR - Clean Air Delivery Rate 52 DMS – Dimethyl sulfide 53 EBRT – Empty bed residence time 54 EPA – Environmental Protection Agency 55 ETS – Environmental tobacco smoke 56 HCHO – Formaldehyde 57 HVAC – Heating, Ventilation and Air Conditioning 58 IAQ – Indoor air quality 59 IEQ - Indoor Environmental Quality 60 LCM – Carbon microspheres 61 LCNT – Carbon nanotubes 62 MERV – Minimum efficiency reporting value 63 MOF – Metal oxide framework 64 NTP – Non-thermal plasma 65 PAN – Polyacrylonitrile 66 PBTF – Plant-based biotrickling filter 67 PBDEs – Polybrominated diphenyl ethers 68 PCO – Photocatalytic oxidation 69 PDMS – Polydimethylsiloxane 70 PE – Polyethylene 71 PAHs – Polycyclic aromatic hydrocarbons 72 4 PM – Particulate matter 73 PP - Polypropylene 74 Ppmv – Volumetric parts-per-million 75 PU - Polyurethane 76 PVC – Polyvinylchloride 77 REACH – Registration, Evaluation and Authorization of Chemicals system 78 RH – Relative humidity 79 rGO – Reduced graphene oxide 80 TPPB – Two-liquid phase partitioning bioreactor 81 TVOC – Total volatile organic compounds 82 UV – Ultraviolet radiation 83 VICs – Volatile inorganic compounds 84 Vis – Visible radiation 85 VOCs – Volatile organic compounds 86 WHO – World Health Organization 87 ZIF – Zeolitic imidazole framework 88 5 1. The indoor air quality problem 89 Air pollution and human exposure to low-quality air is nowadays the most critical 90 environmental threat to public health worldwide according to the World Health Organization 91 (WHO) (World Health Organization, 2016). Recent reports have indicated that, at a global 92 scale, 1 out of 10 deaths are attributable to air pollution. Indeed, air pollution alone caused 93 approximately 5.5 million deaths in 2013 in the world (World Bank and Institute for Health 94 Metrics and Evaluation, 2016). At a European level, recently updated data have ascribed more 95 than 500,000 premature deaths in 2016 to long-term exposure to polluted air, from which 96 412,000 corresponded to particulate matter (PM), 71,000 to NO2, and 15,000 to O3 (European 97 Environmental Agency, 2019). These effects will be even more critical due to the continuous 98 growth of major cities. Indeed, about 90% of the population worldwide lives in urban areas 99 exposed to air quality levels that exceed the WHO guidelines (World Health Organization, 100 2016), which are typically based on PM pollution. 101 The latest studies on human exposure to indoor pollution revealed that indoor environments 102 could be at least twice as polluted as outdoor environments (European Comission, 2003). 103 Indeed, the air in an urban street with average traffic might actually be cleaner than the air in a 104 living room. Traditionally, indoor air pollution has received significantly less attention than 105 outdoor air pollution, especially in highly industrialized or dense traffic areas. However, the 106 threats posed by a long-term exposure to indoor air pollution have become more apparent in 107 recent years (European Environment Agency, 2013) as buildings are progressively sealed 108 against the outside environment to obtain heating and cooling energy cost savings. Many 109 buildings rely entirely on mechanical ventilation to recirculate indoor air with a greatly reduced 110 outdoor air dilution level, leading to the accumulation of indoor pollutants. A recent 111 commission report estimated that nearly 3 billion people worldwide are daily exposed to poor 112 indoor air quality (IAQ) caused by the use of solid fuels for cooking, heating and lighting. This 113 report concluded that household air pollution is a major contributor to global figures for 114 6 morbidity and mortality, with major effects on respiratory and cardiovascular systems (Royal 115 College of Physicians, 2016). Additionally, the report highlighted the significant contribution 116 of poor IAQ to the total number of premature deaths. At a global level, the WHO estimated that 117 each year 4.3 million people die prematurely from illnesses attributable to indoor air pollution 118 (World Health Organization, 2014), almost all in low and middle income countries, with 119 pollutants produced by indoor combustion processes, such as cooking or heating, as the main 120 cause of deficient IAQ. Moreover, the prevalence of health problems related with IAQ such as 121 sick building syndrome, building related illness or multiple chemical sensitivity has been 122 extensively reported (Burge, 2004). Although the levels of indoor air pollutants and their 123 associated symptoms may decrease in new or recently renovated buildings during the first half 124 year, poor IAQ and its associated symptoms have been reported over years (INSHT, 2015). 125 In this context, human exposure to indoor air (houses, workplaces, public buildings or means 126 of transport) exceeds 80 % in developed countries and 85-90 % in Europe (European 127 Comission, 2003) (Figure 1). Likewise, the National Human Activity Pattern Survey in the US 128 revealed that an adult spends 86% of his time indoors, to which a further 6% must be added as 129 time spent inside vehicles or public transport (Marć et al., 2018). There has been a significant 130 global shift in the economy from the manufacturing sector towards the service and knowledge-131 based sectors, which operate in indoor office environments (Al Horr et al., 2016). Poor IAQ has 132 been classified as a priority problem affecting children’s health, while it is considered as one of 133 the largest national environmental threats by the US-EPA (Guieysse et al., 2008). 134 Besides being responsible for many respiratory illnesses, allergies and even cancerous diseases, 135 poor IAQ has also a noteworthy economic impact since it damages valuable objects from 136 libraries, archives or museums, and may reduce employee’s productivity in working places by 137 10-15 % (Cincinelli et al., 2016) (Figure 1). The costs associated to air pollution in the WHO 138 European Region, including exposure to both outdoor and indoor air, amounted to 1.431$ 139 trillions in 2010, from which 42.9$ billion corresponded to Spain (WHO Regional Office for 140 7 Europe, 2015). If only IAQ is considered (in terms of mortality, loss of productivity, and 141 illnesses and sick leaves), recent studies have calculated annual expenses of up to 20,000 142 million € in France (ANSES et al., 2014). 143 144 145 Figure 1. Key data of the indoor air quality problem. 146 147 8 In 2010, the WHO published the first specific IAQ guidelines (World Health Organization and 148 WHO Regional Office for Europe, 2010), which have been since adopted by other organizations 149 in several countries. Whereas these guidelines represented the first attempt to establish a general 150 IAQ standard, only a few priority indoor air pollutants with known adverse health effects were 151 included. Indeed, an exhaustive quantitative regulation comprising all physical, chemical, 152 biological and particulate exposures is rather challenging due to the inherent complexity of 153 indoor air pollution and the lack of information concerning the long-term health effects of each 154 pollutant. In this context, indoor air pollutants include particulate matter, biological pollutants 155 (allergens, bacteria, mold, fungi, spores, etc.), physical agents (temperature, electromagnetic 156 fields) and over 400 different chemical compounds, mainly volatile organic and inorganic 157 compounds (VOCs and VICs, respectively). More recently, organic emerging compounds 158 emitted from plastics, pharmaceuticals or personal care products have been detected in indoor 159 environments. In addition to the wide spectrum of indoor pollutants, their occurrence and 160 concentration depend on many factors such as outdoors air quality, the socio-economic 161 development of the country, type of activities, occupancy, ambient conditions, season of the 162 year, etc. Moreover, pollutant sources and emission rates rapidly change over time (Luengas et 163 al. 2015): endogenous sources include permanent (building materials, adhesives, paints, 164 varnishes, etc.) and occasional sources (furniture, cleaning and disinfection products, cooking, 165 personal care products, human metabolism, etc.), while outdoor pollutants intrusion clearly 166 depends on human activities (road traffic, industry, etc.). Additionally, secondary pollutants 167 might be produced by indoor gas-phase reactions from other compounds present in indoor air 168 (Hubbard et al., 2005; SCHER, 2007). 169 Unfortunately, there is limited information over IAQ due to the great number of pollutants and 170 sources and their variability. Significant efforts must be undertaken in order to better understand 171 the effects of indoor air pollutants on human health and to design ad-hoc regulations to protect 172 human health (Royal College of Physicians, 2016). A better understanding of the type and 173 9 concentration of indoor air pollutants will facilitate the design of effective control strategies 174 both in terms of prevention and active abatement. Since prevention must be considered as the 175 first step for improving IAQ, actions have been recently implemented to reduce or eliminate 176 certain pollutant sources. For instance, smoking in workplaces and most public places is 177 prohibited in Europe and many countries in the world, and the use of harmful construction 178 materials such as asbestos or products containing hazardous components like halogenated 179 pesticides is widely restricted (EU Council, 2008). However, pollution control at source is only 180 possible when sources are known, while new substances are constantly detected and classified 181 as hazardous. Therefore, prevention or minimization of indoor pollutant emissions is commonly 182 insufficient, technically non-viable, or economically unfeasible (Guieysse et al. 2008, Luengas 183 et al. 2015). Moreover, according to the Directive 2010/31/EU (European Parliament, 2010), 184 EU Member States have committed to build nearly zero energy buildings by the end of 2020, 185 while enhancing energy performance during major renovations of existing buildings or 186 retrofitting of building elements. New designs devoted to effective energy savings involve 187 airtight, well-insulated and sealed constructions, which substantially reduces natural 188 ventilation. This increase in building air tightness will cause a severe impact on the levels of 189 gas and particulate indoor air pollutants, increasing their concentration as a result of the reduced 190 ventilation rates (Broderick et al. 2017). In this context of potential conflict between energy 191 efficiency measures and enforcement of IAQ standards, the development and optimization of 192 versatile technologies for in-situ indoor air purification is increasingly needed. 193 194 2. Main pollutants and sources 195 The most important indoor air pollutants investigated include particulate matter, volatile 196 inorganic compounds and volatile organic compounds. Particulate matter is typically classified 197 as a function of its size, but the most reported value corresponds to the concentration of particles 198 with a mean diameter lower than 2.5 micrometers (PM2.5). Carbon dioxide (CO2), carbon 199 16 Leung, 2015; World Health Organization and WHO Regional Office for Europe, 2010). No 307 safe level of exposure is recommended. The highest level of benzene has been recorded in 308 shopping areas (2.5-48 μg/m3) followed by offices (1.4-5.5 μg/m3), homes (0.7-4.4 μg/m3) and 309 schools (0.5-3 μg/m3) (Broderick et al., 2017; Dodson et al., 2008; Du et al., 2015; Edwards et 310 al., 2001; Geiss et al., 2011; Kotzias et al., 2009; Langer et al., 2015; Rösch et al., 2014; Singh 311 et al., 2016; Xu et al., 2016; Zielinska et al., 2012). 312 Toluene is also an aromatic compound used in several industrial processes and emitted also by 313 power generation industries and traffic (Campagnolo et al., 2017; Jantunen et al., 1998; Kotzias 314 et al., 2005; Leung, 2015; Royal College of Physicians, 2016). Toluene, present in gasoline, 315 paints, resins, adhesives, cosmetics and coatings, is one of the most common indoor air 316 pollutants and the most abundant among BTEX (benzene, toluene, ethylbenzene and xylene). 317 Indoor sources are infiltration from outdoor air, tobacco smoke, combustion devices and a 318 variety of household products (Carazo Fernández et al., 2013; Jantunen et al., 1998; Kotzias et 319 al., 2005; Royal College of Physicians, 2016; SCHER, 2007; Singh et al., 2016). Toluene is not 320 a confirmed carcinogenic substance, and therefore no long-term health effects have been 321 studied yet. Exposure to toluene increases risks of developing asthma and other respiratory 322 conditions, while short and long-term exposure can affect central nervous system (Kotzias et 323 al., 2005). Shopping complexes present the highest toluene concentrations (15-164 μg/m3), 324 followed by offices (6-32 μg/m3) and homes (3-20 μg/m3). The presence of toluene in schools 325 is marginal (1.8 μg/m3). Concentrations are typically higher in new or recently renovated 326 buildings as a result of the new installed materials (Broderick et al., 2017; Dodson et al., 2008; 327 Du et al., 2015; Edwards et al., 2001; Geiss et al., 2011; Langer et al., 2015; Mandin et al., 328 2017; Rösch et al., 2014; Singh et al., 2016; Xu et al., 2016; Zhong et al., 2017; Zielinska et al., 329 2012). 330 Ethylbenzene is a colorless liquid compound at ambient temperature, with a strong gasoline-331 like scent. Sources of pollution include plastics, paints, adhesives and other products where 332 17 ethylbenzene is used as a solvent during manufacturing. Ethylbenzene is also emitted during 333 combustion processes such as traffic (ethylbenzene is included in gasolines), heating devices 334 and cooking (Campagnolo et al., 2017; Jantunen et al., 1998; Leung, 2015; Singh et al., 2016). 335 Acute effects at relatively high concentrations include eye and throat irritation and dizziness. 336 No long-term effects have been described yet in humans. Ethylbenzene has been classified as a 337 potential human carcinogen by the International Agency for Cancer Research (ATSDR, 2007). 338 Concentrations of ethylbenzene up to 16 μg/m3 have been detected in offices and shopping 339 complexes. On the other hand, homes and schools exhibit maximum concentrations of 8 and 340 0.2 μg/m3, respectively (Broderick et al. 2017; Dodson et al. 2008; Edwards et al. 2001; Rösch 341 et al. 2014; Singh et al. 2016; Xu et al. 2016; Zhong et al. 2017; Zielinska et al. 2012). 342 Xylene is a colorless liquid at room temperature with an aromatic odor present as three isomers: 343 ortho, meta and para (o-, m- and p-, respectively). Xylene is used as a solvent in industry and 344 as an additive in gasoline. Indoor sources of xylenes include paints, adhesives, dyes, polymers, 345 cleaning products and pharmaceuticals. Outdoor air is also a source of indoor pollution if dense 346 traffic or industrial facilities using xylene are nearby (Campagnolo et al., 2017; Jantunen et al., 347 1998; Kotzias et al., 2005; Leung, 2015; SCHER, 2007; Singh et al., 2016). An acute exposure 348 to xylene can cause eye and throat irritation, headache and nausea. Long-term exposure is 349 associated with problems in the respiratory, gastrointestinal and central nervous systems, lungs, 350 kidney, heart and reproductive system. Xylene is a suspected carcinogenic chemical, associated 351 with an increased risk of leukemia, non-Hodgkin’s lymphoma and colon/rectum cancer 352 (Kotzias et al., 2005). Shopping areas, with levels ranging from 1.3 to 74 μg/m3, and offices, 353 with levels of 2.2 to 16 μg/m3, rank among the most polluted sites. Maximum xylene 354 concentrations of 3.1 and 0.3 μg/m3 have been measured at homes and schools (Broderick et al. 355 2017; Dodson et al. 2008; Edwards et al. 2001; Geiss et al. 2011; Langer et al. 2015; Mandin 356 et al. 2017; Singh et al. 2016; Vasile et al. 2016; Xu et al. 2016; Zhong et al. 2017; Zielinska et 357 al. 2012). 358 18 Naphthalene is a white crystalline solid at ambient temperature, with a characteristic aromatic 359 odor (mothballs), widely used as a raw material in the chemical industry. The main emission 360 source is traffic as a result of the inherent presence of naphthalene in gasoline and diesel. Indoor 361 sources include tobacco smoke, defective combustion devices, herbicides, rubber materials and 362 insect repellents (usually contaminating clothes) (Kotzias et al., 2005; Royal College of 363 Physicians, 2016; World Health Organization and WHO Regional Office for Europe, 2010). 364 Outdoor air is a mayor source in high-traffic and industrial areas. Inhalation is the principal 365 naphthalene intake mechanism in humans, although accidental ingestions of mothballs have 366 been reported. Acute naphthalene intoxication can induce hemolytic anemia and cataracts. No 367 long-term adverse health effects or evidence of human carcinogenicity or genotoxicity have 368 been reported (Kotzias et al., 2005; World Health Organization and WHO Regional Office for 369 Europe, 2010). Naphthalene concentrations ranging from 3 to 26 μg/m3 have been recorded at 370 homes (Du et al. 2015; Xu et al. 2016; Zhong et al. 2017). 371 Formaldehyde (HCHO) is a colorless, odorous, highly reactive gas emitted during incomplete 372 reaction of hydrocarbons in industries, traffic and other processes. Formaldehyde is also 373 produced by oxidation of other VOCs with ozone or radiation (Campagnolo et al., 2017; Kotzias 374 et al., 2005; US Environmental Protection Agency, 1995; World Health Organization and WHO 375 Regional Office for Europe, 2010). This chemical is widely used in resins, glues, paints, paper 376 products, cosmetics, electronic equipment, cleaning agents or fabrics. Formaldehyde is present 377 in construction materials such as insulation foams of wooden-based materials employed in 378 floorings or furniture. However, emissions from these materials (e.g. plywood, particleboard or 379 fiberboard) usually decay within several weeks (Carazo Fernández et al., 2013; Jantunen et al., 380 1998; Kotzias et al., 2005; Royal College of Physicians, 2016; World Health Organization and 381 WHO Regional Office for Europe, 2010). Formaldehyde is rapidly absorbed by the respiratory 382 or gastrointestinal system. Acute exposure effects include odor, irritation, headache and 383 eczema. Formaldehyde is a known carcinogenic and genotoxic chemical, whose long-term 384 19 exposure can originate nasopharyngeal cancer and myeloid leukemia (Kotzias et al., 2005; US 385 Environmental Protection Agency, 1995; World Health Organization and WHO Regional 386 Office for Europe, 2010). The level of exposure in homes, offices and schools is comparable 387 (7.7-30, 8-17, 9-17 μg/m3) (Broderick et al., 2017; Canha et al., 2017; Dodson et al., 2008; 388 Geiss et al., 2011; Kotzias et al., 2009; Langer et al., 2015; Mandin et al., 2017; Prasauskas et 389 al., 2016; Zhong et al., 2017; Zielinska et al., 2012). 390 Trichloroethylene (TCE) is a volatile chemical with sweet chloroform odor, widely produced 391 by the industry, and used as solvent and cleaning agent (vapor degreasing of metals). TCE can 392 be present in contaminated waters and soils, which could indirectly contribute to indoor levels. 393 Indoor sources include products where TCE is used as solvents such as lubricants, varnishes, 394 paint removers, adhesives and typewriter correction fluids. TCE can be also present in some 395 bleach household products and other cleaning agents (Jantunen et al., 1998; Singh et al., 2016; 396 World Health Organization and WHO Regional Office for Europe, 2010). Human exposure to 397 this VOC occurs by dermal absorption, ingestion and inhalation. Exposure to TCE is often 398 intermittent, as the products that contain this pollutant are not constantly used. Acute exposure 399 to TCE affects the central nervous system at concentrations of ~270 mg/m3, causing a reduced 400 sensorial capacity. TCE is a carcinogenic chemical under long-term exposure, and a chronic 401 exposure may cause liver, kidney and bile duct cancer and non-Hodgkin’s lymphoma. 402 Therefore, no safe threshold is recommended due to its carcinogenicity (World Health 403 Organization and WHO Regional Office for Europe, 2010). TCE concentrations ranging from 404 0.3 to 0.6 μg/m3 are typically recorded at homes, and from 0.6 to 4.7 μg/m3 in shopping 405 complexes (Dodson et al., 2008; Edwards et al., 2001; Mandin et al., 2017; Singh et al., 2016; 406 Xu et al., 2016). 407 Alpha-pinene is a colorless liquid with a strong pine scent. This terpene is naturally present in 408 plants and a common constituent of essential oils. Pinene is used as a solvent in some paints 409 and waterproof substances, and can be found in perfumery products, deodorizers and cleaning 410 20 products. Pinene emissions can also originate from wooden materials like furniture or flooring, 411 particularly those made from pine wood (Campagnolo et al., 2017; Kotzias et al., 2005; Luengas 412 et al., 2015; Royal College of Physicians, 2016). No significant pinene concentrations are found 413 outdoors, except in forest areas. On the other hand, limited data of pinene health risks is 414 available. While acute exposure to high concentration can produce irritation and inflammation, 415 no chronic exposure risks have been reported yet. Health risks might be expected when ozone 416 or other reactive radicals are present, due to their high reactivity with pinene and other 417 unsaturated molecules (Hubbard et al., 2005; Kotzias et al., 2005; Leung, 2015; SCHER, 2007). 418 These reaction by-products would produce eye and upper airways irritation in a more extended 419 way than pinene itself. The largest pinene concentrations are found at homes (11-32 μg/m3) and 420 libraries (10-30 μg/m3), while offices and schools exhibit concentrations up to 6.3 and 1.5 421 μg/m3, respectively (Dodson et al. 2008; Edwards et al. 2001; Geiss et al. 2011; Langer et al. 422 2015; Mandin et al. 2017; Rösch et al. 2014; Xu et al. 2016; Zhong et al. 2017). 423 Limonene is a natural terpene present as two isomers (d- and l-), which have citric and pine 424 scent, respectively. Limonene is used in a wide variety of household products like cleaning 425 agents, resins, air fresheners, deodorants, fragrances and shampoos (Campagnolo et al., 2017; 426 Kotzias et al., 2005; Luengas et al., 2015; Royal College of Physicians, 2016). This terpene is 427 also found in food as an additive due to its citric odor and flavor. Limonene intake occurs by 428 inhalation or ingestion. This pollutant has low acute toxicity, no symptoms further than eye or 429 skin irritation have been described. Chronic health effects for limonene have not been studied, 430 and there is no evidence of carcinogenicity or genotoxicity. Heath risks are associated to 431 ambient reaction with ozone or reactive radicals, which form byproducts such as aldehydes, 432 carboxylic acids and peroxides, responsible of irritation and odor annoyance at low 433 concentrations (Hubbard et al., 2005; Kotzias et al., 2005; Leung, 2015; SCHER, 2007). 434 Maximum concentrations of 32, 19 and 11 μg/m3 have been recorded at homes, offices and 435 schools, respectively (Dodson et al., 2008; Du et al., 2015; Edwards et al., 2001; Geiss et al., 436 21 2011; Langer et al., 2015; Mandin et al., 2017; Rösch et al., 2014; Xu et al., 2016; Zhong et al., 437 2017). 438 439 3. Prevention of indoor air pollutant emission 440 Among the different approaches to control indoor air quality, prevention of pollutant formation 441 and emission rank first in terms of cost-effectiveness. Several strategies to prevent the emission 442 and to decrease the concentration of gas pollutants in indoor environments have been proposed. 443 Overall, ventilation is the easiest measure to prevent the accumulation of indoor pollutants. 444 Indoor pollutant concentrations typically decrease when increasing outdoor air exchange rate 445 unless outdoor pollutant concentrations are high (such as in areas with intense traffic or 446 industrial activities). Mechanical ventilation systems introduce outdoor fresh air into the 447 building, which dilutes the concentration of indoor air pollutants. Some sources can be sealed 448 or removed by professionals, like asbestos and other insulation fibers (Chenari et al. 2016; 449 Kotzias et al. 2005; Leung 2015; Luengas et al. 2015). Smoking bans are also a very effective 450 measure since tobacco smoke is a source of multiple harmful chemicals in elevated 451 concentrations. The suppression of tobacco smoke in indoor places has resulted in consistent 452 IAQ improvements (Kotzias et al., 2005; US Environmental Protection Agency, 1995). Finally, 453 an adequate control of the relative humidity and temperature is crucial to control the emissions 454 of organic pollutants from indoor materials. In this context, air conditioning systems can control 455 the temperature and relative humidity, potentially using smart systems to automatize 456 ventilation or heating depending on the indoor atmosphere (high CO2 levels, low temperatures) 457 or occupants’ activities (Chenari et al. 2016; Luengas et al. 2015; Zhou et al. 2017). 458 Many indoor air pollutants, including PM, BTEX, NOx or CO, are emitted during combustion 459 processes at homes, such as cooking or heating. Increased ventilation rates and the reduction of 460 these combustion gases from cooking stoves, boilers or fireplaces prevent indoor pollutant 461 accumulation. Combustion devices in buildings must be regularly checked and maintained to 462 22 prevent malfunctioning and emissions of harmful pollutants to the indoor atmosphere (Carazo 463 Fernández et al., 2013; Leung, 2015; SCHER, 2007; US Environmental Protection Agency, 464 1995). Highly polluting fuels like biomass or kerosene need to be replaced by more efficient 465 fuels such as natural gas or electricity at homes, although there is an increasing popularization 466 of biomass in developed countries due to its higher sustainability. This effect was demonstrated 467 in rural kitchens in Nepal, where emissions of PM2.5 from different fuels were investigated. A 468 remarkable improvement in IAQ when using electricity and liquified petroleum gas (PM2.5 469 levels of 80 and 101 μg/m3, respectively) compared to wood and rice husk (PM2.5 levels of 630 470 and 656 μg/m3, respectively) (Pokhrel et al., 2015). In addition, improved cooking stoves have 471 been proved to reduce emissions of PM and CO (Armendáriz-Arnez et al., 2010; Sidhu et al., 472 2017; Yip et al., 2017). Other combustion sources, such as candles or scented incense, may also 473 contribute to a reduced IAQ (Kotzias et al., 2005). 474 Some VOCs are emitted from common construction materials. The manufacture of some 475 wooden-based materials, like plywood or fiberboard, often implies the utilization of resins and 476 varnishes that contain formaldehyde and other VOCs. Paints, glues, plastics and other 477 construction materials include VOCs (usually BTEX) as solvents or additives. Some of these 478 emissions can be prevented by using low-emitting materials like improved plastics and paints 479 (phenol resins instead of urea resins, polyurethane coatings, etc.) and solid wood or old furniture 480 (Carazo Fernández et al. 2013; Environmental Protection Agency 1995; Kotzias et al. 2005; 481 Wei et al. 2015). 482 Occupancy of buildings should be avoided during several weeks after construction or 483 renovation, as pollutant emissions from these sources typically decrease in time until reaching 484 low emission steady state levels. Indeed, pollutant concentrations were found higher even four 485 months after renovation (Broderick et al., 2017). Similarly, emissions of VOCs from paints, 486 adhesives, cleaning products and fuels can be partially mitigated by properly sealing and storing 487 23 these liquid materials and minimizing storage periods to prevent leakages and emissions (US 488 Environmental Protection Agency, 1995). 489 A wide variety of indoor pollutants originate from household and personal care products. Some 490 compounds like pinene and limonene are used as scents in cleaning products, deodorants, 491 cosmetics and even in food (Carazo Fernández et al., 2013; Kotzias et al., 2005; SCHER, 2007). 492 Pollutant emissions can be partially avoided by using household products according to 493 manufacturer instructions (good ventilation, no mixing, being aware of warnings). In addition, 494 unused or nearly empty containers should not be stored for long periods and must be disposed 495 safely (Environmental Protection Agency 1995; Wei et al. 2015). 496 497 4. Physical-chemical technologies for indoor air treatment 498 The intrusion or generation of indoor air pollutants cannot always be reduced or suppressed in 499 a cost-effective or technically feasible manner. In these scenarios, active abatement units can 500 be installed in order to lower or eliminate the levels of indoor air contaminants. Traditionally, 501 these devices consisted of physical-chemical technologies such as filters or ozonisers installed 502 as part of a central heating and ventilation system or operated as portable units (Luengas et al., 503 2015). Real-time sensing has been applied to these devices to optimize their performance. These 504 sensors on-line monitor ambient conditions (temperature, humidity, concentrations of key 505 pollutants) and activate the abatement units based on the need of the occupants and their 506 activities, with the subsequent energy savings (Guyot et al., 2018; Kumar et al., 2016; Tran et 507 al., 2017; Yang et al., 2019). Today, the market of physical/chemical technologies for indoor 508 air treatment is dominated by mechanical and electronic filtration, adsorption and ozonation 509 (Tables 2 and 3).510 24 Design parameters Air flow (m 3 /h) Single pass efficiency (%) Reference Mechanical filtration Multilayer (glass + synthetic fibers) non-woven filter (≈ MERV 16 filter) filter installed in HVAC system 5.08cm depth 2.5 m/s Black Carbon: 88% / Ultrafine PM: 86% PM(0.3-2.5 μm): 91% / PM(>2.5 μm): 88% (Polidori et al., 2013) MERV16 filter + 12 gas-phase filters + particle postfilter Dimensions: 0.41m 2 ×1.95m (portable) 1362 Black Carbon: 90% / Ultrafine PM: 94% PM(0.3-2.5 μm): 92% / PM(>2.5μm): 75% (Polidori et al., 2013) PVC/PU fibers (8 w/w%) on filter paper support Membrane: 100 cm2, 20.72 g/m2 1.91 / 5.01 PM (0.3-0.5 μm): >99.5% (Wang et al., 2013) Polyester filter with sericin coating 145 PM(2.5,10 μm): ≈56% (Verma et al., 2019) ZIF8-SiO2 nanofiber composite membrane (2h growing time) Dimensions: Ø30mm disc (7.07cm 2 ) 0.05 Soft smoke PM: > 99.95% (Zhu et al., 2019) Double layer nonwoven filter: PP-g-DMAEMA (Dimethylaminoethylmethacrylate)-rGO (reduced graphene oxide) (6.3%) + PP-g-DMAEMA sheet Filter: 25g/m 2 19.2 65% (PP-DMAEMA-rGO) 76.4% (PP-DMAEMA) 72.2% (Double Layer) (Tang et al., 2020) Electronic filtration Ion-spray with carbon fiber electrodes (charger and plates) Charger outside-mounted (emit ions to ambient air) Dimensions: 120×185×85mm 3 120 PM (0.3μm; laboratory): 47.8% PM (0.3μm; real chamber): 39.8% (Sung et al., 2019) Electrostatic precipitator based on corona discharge and parallel plates 120 PM (0.3/0.5/1/3): 67.7/67.7/40.6/14.5% (Zeng et al., 2020) 511 Table 2. Performance of physical-chemical technologies for the removal of particulate matter. 512 513 25 Design parameters Air flow (m 3 /h) Pollutant Removal Capacity Single Pass Efficiency (%) Reference Adsorption Indoor passive panels (gypsum based; different treatments) Dimensions: 0.089 m2 0.2 HCHO: 40-140 μg/m2·h Toluene: 30-210 μg/m2·h - (Zuraimi et al., 2018) Granular activated carbon Ø46mm, 150mm tube ; 7.0 g of adsorbent Thermal desorption (300ºC) 0.06 - Benzene: 81.5-91.6 Toluene: 86.6-100 Ethylbenzene: 91.6-99.2 Xylene: 89.9-100 (Jo and Yang, 2009) Porous ferrihydrite/SiO2 composite (different aging times) ; 0.27g of adsorbent in Ø140mm petri - HCHO: 6.30-8.11 mg/g 6mg/g after 7 cycles (Xu et al., 2013) Polyester filter with sericin coating 145 - Benz: 2.96 ; Tol: 2.96 Et-Benz: 3.71 ; Xyl: 4.18 (Verma et al., 2019) Carbon nanotubes (LNCT) and carbon microspheres (LCM) Dimensions: Ø16mm, 90mm ; Adsorbent: 3g 0.001 Tol / Et-Benz / o -xyl LCNT: 52.2, 78.0, 102 mg/g LCM: 47.1, 64.0, 62.7 mg/g Tol / Et-Benz / o -xyl LCNT: 57.8, 47.5, 61.8 LCM: 51.7, 53.5, 52.6 (Srivastava et al., 2019) Alkaline-treated carbon nanotubes (LNCT) and carbon microspheres (LCM) Dimensions: Ø16mm, 90mm ; Adsorbent: 2g 0.001 Tol / Et-Benz / o -xyl LCNT: 1821, 964, 1076 mg/g LCM: 1093, 895, 996 mg/g Tol / Et-Benz / o -xyl LCNT: 84.0, 83.3, 82.6 LCM: 82.5, 83.4, 74.8 (Srivastava et al., 2019) High-grade activated carbon filter (portable) 510 HCHO: 0.6 ; Toluene: 32.0 n-decane: 40.0 Tetrachloroethylene: 31.3 (Chen et al., 2005) Activated carbon prefilter (portable) 569 HCHO: 0.2 ; Toluene: 7.8 n-decane: 12.5 Tetrachloroethylene: 6.0 (Chen et al., 2005) 32 for human health and only some air pollutants are effectively destroyed. The high cost of lamp 568 acquisition and intensive energy consumption rank among the main disadvantages of this 569 technology. In addition, undesired compounds such as ozone or secondary organic pollutants 570 might be released to indoor air as a result of the unspecific action of UV radiation (Chen et al., 571 2005; Guieysse et al., 2008; Luengas et al., 2015). The performance of stand-alone photolysis 572 units was not herein evaluated since this technology is commonly implemented as 573 photocatalytic oxidation. 574 Photocatalytic oxidation (PCO) utilizes catalytic semiconductors to create reactive radicals 575 from ambient O2 and radiation (generally UV), which further react with indoor air pollutants. 576 TiO2 is the most popular catalyst due to its low cost, non-toxicity, biocompatibility and 577 effectiveness. Other metallic oxides and sulfides (SnO2, ZnO, CdS) are also used as catalysts 578 (Chen et al., 2005; Mo et al., 2009). This technology can cope with a larger spectrum of 579 pollutants than photolysis (Guieysse et al., 2008). The generation of harmful radicals and 580 secondary organic aerosols, along with the high costs of catalyst media replacement, limit the 581 widespread use of this technology (Chen et al., 2005; Luengas et al., 2015). Single pass 582 efficiencies in photocatalytic devices are pollutant and catalyst specific. For instance, Feng et 583 al. (2017) reported a removal efficiency of 60% for formaldehyde (Feng et al., 2017), while 584 Zeng et al. (2020) reported a 75% removal of TVOC (Zeng et al., 2020). The areal elimination 585 capacity is an important design parameter in PCO, with values as high at 3414 mg/m2·h reported 586 for acetaldehyde (Roso et al., 2019) (Table 3). 587 Plasma consists of a cloud of highly ionized gas containing electrons, positive ions, oxidants 588 and free radicals able to degrade organic pollutants, precipitate particulate matter and kill 589 pathogens (Luengas et al., 2015). Non-thermal plasma (NTP) is generated at ambient 590 temperature by high voltage discharges (usually corona discharge) at the expenses of a high 591 energy consumption. Similarly to UV or photocatalytic oxidation, plasma mediates the 592 generation of O3 and other by-products or oxidation intermediates that may be as dangerous for 593 33 human health as the parent pollutants (Chen et al., 2005; Luengas et al., 2015). NTP can achieve 594 removal efficiencies of up to 90% for VOCs (Van Durme et al., 2009) and microorganisms 595 (Liang et al., 2012), although operation under real conditions (i.e. high humidity and low 596 pollutant concentrations) could reduce its abatement performance (Table 3). 597 Membrane separation is based on the transfer of indoor air pollutants to another fluid through 598 a semipermeable membrane. This technology has been consistently proven at high pollutant 599 concentrations, but its efficiency at the low levels of pollutants found in indoor air is not 600 guaranteed (Guieysse et al., 2008). Mechanical resistance and pressure drop, and therefore 601 operational costs, are higher compared to other technologies. In addition, VOCs captured on 602 the other side of the membrane must be appropriately managed or destroyed in a separate unit 603 (Guieysse et al., 2008; Luengas et al., 2015). Membrane separation is still a developing 604 technology in indoor air treatment. 605 Overall, there is no single physical-chemical technology capable of coping with all indoor air 606 pollutants in a cost-effective manner, which requires the use of sequential technology 607 configurations at the expenses of superior capital and maintenance costs. Mechanical filtration 608 is typically installed to eliminate particulate matter prior to other abatement technology 609 (Luengas et al., 2015). The broad nature of VOCs and VICs requires tandems of gas pollutant 610 abatement technologies. For instance, Jo and Yang (2009) reported removal efficiencies of 611 BTEX of ~100% using a granular activated carbon adsorbent coupled with a PCO-TiO2 unit 612 (Jo and Yang, 2009). Likewise, Zhu et al. (2019) (Zhu et al., 2019)(Zhu et al., 2019)achieved 613 a removal efficiency of 80% for formaldehyde, with an adsorption capacity of 48.9 mg/g (gram 614 of adsorbent) (Zhu et al., 2019). Zhang et al. (2020) recorded capacities of up to 164.4 mg/g for 615 toluene and 275.3 mg/g for acetaldehyde (Zhang et al., 2020), while a capacity of 39.1 mg/g 616 has been reported by Tang et al. (2020) for benzene, toluene and xylene (Tang et al., 2020) 617 (Table 3). 618 619 34 5. Biological Based Purification Methods 620 The performance of conventional physical-chemical methods for indoor air purification is 621 hampered by the low concentrations, the diversity and the variability of VOCs in indoor 622 environments. However, these limitations represent an opportunity for biological based 623 purification systems. Biotechnologies are based on the action of microorganisms or plants, 624 which are able to eliminate or transform the gas pollutants by utilizing them as energy and/or 625 carbon source for either cell maintenance or replication (Guieysse et al., 2008). Overall, indoor 626 air pollutant biodegradation relies on the action of oxidative enzymes, which function at 627 ambient pressure and temperature without the need of additional chemicals. In botanical 628 technologies, both plant and soil microenvironment are responsible of pollutant degradation. 629 On the other hand, gas-water contactors are based on the biocatalytic action of suspended or 630 immobilized microorganisms, which bio-convert air pollutants into CO2, H2O and new 631 microorganisms. These microorganisms need to be integrated by diverse, versatile and adaptive 632 microbial communities of bacteria, fungi, microalgae or yeasts able to remove simultaneously 633 a wide spectrum of pollutants at variable concentrations without generating undesirable by-634 products (Soreanu, 2016). Microorganisms are typically present as biofilms, which consist of a 635 moist layer of cells adhered to the surface of a support material. Biofilms provide a protected 636 environment to microorganisms and support a direct contact between the gas pollutants and 637 cells, which enhances pollutant mass-transfer, a commonly limiting parameter in gas-phase 638 bioreactors (Guieysse et al., 2008; Soreanu, 2016; Soreanu and Dumont, 2020). 639 Biotechnologies have been successfully developed for industrial applications, where varying 640 concentrations of multiple gas pollutants from different sources are cost-effectively treated 641 (Estrada et al., 2011; Kennes and Veiga, 2013; Soreanu and Dumont, 2020; Van Groenestijn 642 and Kraakman, 2005). However, the potential of biotechnologies for indoor air purification 643 remains unexplored due to the particular and challenging conditions of indoor environments 644 (Pacheco-Torgal et al., 2015). Mass-transfer limitations and the rapidly changing 645 35 concentrations of a large spectrum of gas pollutants are the main drawbacks associated with 646 indoor air treatment. Additionally, a cost-competitive CO2 removal and the control of biological 647 hazards need to be addressed prior in-house implementation of biotechnologies. Biological-648 based purification systems for indoor air would improve the energy efficiency of buildings, 649 while providing additional benefits in indoor environmental quality such as aesthetic and 650 psychological improvements (Guieysse et al., 2008; Moya et al., 2019). As indoor environments 651 are often condensed spaces, biotechnologies need to be compact and aesthetically integrated 652 units with high effectiveness treating large air flowrates. In this context, new configurations of 653 bioreactors such as membrane, capillary or two-phase reactors have been successfully tested to 654 maximize the mass-transfer of gas pollutants (Kraakman et al., 2011; Muñoz et al., 2012; 655 Soreanu, 2016). Alternatively, botanical biofiltration could have additional economic, 656 environmental and social benefits, including remarkable psychological impacts of ‘greening’ 657 the indoor space with plants. In addition, plants are able to effectively decrease CO2 658 concentration, which has been proved to impact on human decision-making performance 659 (Satish et al., 2012). 660 The most common technologies for indoor air treatment are discussed below. Furthermore, 661 some examples of these purification methods and their principal operational characteristics are 662 shown in Table 4 and in Figure 3. 663 36 664 Figure 3. Schematic operational configurations of different air purification biotechnologies.665 37 Description of the Technology Air flow (m3/h) EBRT (min) Removal Efficiency (%) Elimination capacity (mg/m 3 ∙h) Inlet concentration Inlet load Reference Botanical technologies Active potted plant: Epipremnum aureum (2) Filter bed: 0.35×0.2×0.15 m3, granular activated carbon + shale pebbles (1:1 mixture; Ø5 mm) 5.1 m 3 chamber 50 m3/h HCHO: 19.9-32.7% at RH55-90% HCHO: 824±15 μg/m3 (Wang et al., 2014) Biowall: Philodendron scandens (18) + Philodendron scandens 'Brazil' (13) + Asplenium antiquum (19) + Syngonium podophillum (13) 1.5 m2 module; 30 m3 chamber Support: inorganic media + activated carbon 50 m3/h Butanone: 55.1-58.5% Butanone: 39.4-44.8 μg/m3 (Torpy et al., 2018) Biofilters Compost/perlite (75:25) as packing (8.5L) 120 cm, Ø10 cm PVC reactor Activated sludge as inoculum 1.57-0.53 min H 2 S: >99% Toluene: >99.9% Butanone: >98.9% H 2 S: 23.6-43.3 mg/m3 Toluene: 0.40-0.60 mg/m3 Butanone: 4.3-6.3 mg/m 3 (Lebrero et al., 2011) Compost as packing 2L PVC column (53 cm, Ø8.3 cm) Irrigation flow rates: 30/120 mL/day Activated sludge as inoculum 0.72/0.30 min MeSH: >98%; ≈1.2 g/m3∙h Toluene: >98%;≈0.22 g/m3∙h α-pinene: >98%;≈0.25 g/m3∙h n-hexane: 96-98%; ≈0.20 g/m 3 ∙h MeSH: 410-980 mg/m3∙h Toluene: 69-164 mg/m3∙h α-pinene: 76-182 mg/m3∙h n-hexane: 63-150 mg/m 3 ∙h (Lebrero et al., 2014) Compost/pozzolan (80:20) as packing (3.8L) 0.25 m, Ø0.1 m reactor Activated sludge as inoculum 0.38 min Toluene: ≈100%; ≈23.9 mg/m3∙h p-xylene: ≈65-100%; ≈14 mg/m 3 ∙h Toluene: 0-25 mg/m3∙h p-xylene: 0-22.5 mg/m3∙h (Luengas et al., 2017) Biotrickling filters Pseudomonas putida embedded in calcium alginate gel (granules); 30 cm, Ø6 cm column (4 beds); Liquid flow: 1.23 L/day 0.09 m3/h HCHO: 68.6-93.5%; 25-158.4 mg/m3∙h ≈0.2-1.34 mg/m3 (Lu et al., 2012) 38 PU foam as packing (2L, 1cm3 cubes); PVC column (53 cm,Ø8.3 cm); Liquid flow: 1.5 m/h Activated sludge as inoculum 0.07-0.72 min MeSH: >97%; ≈1.2 g/m3∙h Toluene: >97%; ≈0.22 g/m3∙h α-pinene: >97%; ≈0.25 g/m3∙h n-hexane: 88-95%; ≈0.20 g/m 3 ∙h MeSH: 410-980 mg/m3∙h Toluene: 69-164 mg/m3∙h α-pinene: 76-182 mg/m3∙h n-hexane: 63-150 mg/m 3 ∙h (Lebrero et al., 2014) PU foam as packing (48 cubes; 4×4×4 cm3) Acrylic 8×8×76 cm3 reactor Liquid flow: 0.3/0.5 L/min Activated sludge as inoculum 0.12/0.30 m3/h 1.53/0.61 min VOCs (normalized carbon content) 78-87%; 1.2-9.3 mgcarbon/m3∙h 1.5-10.7 mgcarbon/m3∙h (Saucedo- Lucero and Revah, 2018) PE Ralu-rings (1.5×1.5 cm2) as packing (60 cm high); 100 cm, 48L reactor; Liquid flow: 1.2 m3/h Enriched culture inoculum 3.0-9.0 m3/h 0.96-0.32 min Ethanol: 100%; 5-22 g/m3∙h DMS:10-100%; 0.65-6.6 g/m3∙h Optimal 95% (low gas flux) Ethanol: 5-22 g/m3∙h DMS: 2.8-8.5 g/m3∙h (Bak et al., 2017) Membrane biotechnologies Porous acrylonitrile support (50μm) + PDMS layer (0.3μm); 40 cm2 membrane in 200×5×2 mm3 (8mL) compartments; Liquid flow: 0.03 L/min Activated sludge + hydrophobic bacteria as inoculum (+ silicon oil); 1.0-0.12 min Acetone: 95-100% Toluene: 93-100% n-hexane: 7-28% Limonene: 88-100% Acetone: 0.1-10.2 mg/m3∙h Toluene: 0.2-13.4 mg/m3∙h n-hexane: 0.1-5.6 mg/m3∙h Limonene: 0.1-9.6 mg/m3∙h (Lebrero et al., 2013) Commercial hollow-fiber membrane reactor (10600 PDMS fibers, Ø190 μm; V: 300 mL; A: 8300 cm2); Liquid flow: 0.2 L/min; Activated sludge as inoculum 1.4-0.27 min MeSH: 8.5-98%; ≈0.58 g/m3∙h Toluene: 67-99%; ≈0.11 g/m3∙h α-pinene: 70-99%; ≈0.12 g/m3∙h n-hexane: 38-58%; ≈0.09 g/m 3 ∙h MeSH: 210-1103 mg/m3∙h Toluene: 35-185 mg/m3∙h α-pinene: 39-205 mg/m3∙h n-hexane: 32-169 mg/m 3 ∙h (Lebrero et al., 2014) Hybrid technologies Biofilter + Adsorption system Pyrex column (23 cm, Ø10 cm) packed with compost + Activated carbon adsorption column (2.9 cm, Ø2.5 cm column) 0.5 m3/h 0.22 min (BF) 0.002 min (AC) Toluene: 88.2-98.2% (BF) Toluene: 84.9-99.9% (BF+AC) Toluene: 17-52 μg/m3 (4.2-14 mg/m3∙h) Peaks of 733±55 μg/m3 (200±20 mg/m 3 ∙h) (Hort et al., 2014) 39 Biofilter + Adsorption system 25 cm, Ø10 cm reactor; Compost/pozzolan (80:20) packing (1.26L) + Activated carbon (1.26L) column Activated sludge as inoculum 0.13-0.04 min Toluene: ≈100% (at 45 mg/m3∙h), up to 80 mg/m3∙h (BF); ≈100%, up to 187 mg/m3∙h (AC) p-xylene: ≈100% (at 32 mg/m3∙h) up to 32 mg/m3∙h ((BF); ≈100%, up to 63 mg/m 3 ∙h (AC) Toluene: 0-235 mg/m3∙h p-xylene: 0-63 mg/m3∙h (Luengas et al., 2017) Biofilter + Adsorption system 25 cm, Ø10 cm reactor; Compost/pozzolan (80:20) packing (1.26L) + Activated carbon (1.26L) column Activated sludge as inoculum 0.13-0.04 min Toluene: 100% at 45 mg/m3∙h (BF); 100% at 187 mg/m3∙h (AC) p-xylene: 100% at 32 mg/m3∙h (BF); 100% at 63 mg/m3∙h (AC) Toluene: 0-235 mg/m3∙h p-xylene: 0-63 mg/m3∙h (Luengas et al., 2017) Bag filter + Photocatalytic reactor + BTF Bag filter: 90 cm, Ø60 cm reactor PC: 45×45×100 cm3; 10 UV lamps; 20 Ni foam plates (21.5×25.0 cm2) coated with TiO2 BTF: 220 cm, Ø40 cm reactor; ceramic beads/ Raschig rings (50:50) packing; 6×12cm bed layers 200 m3/h TVOC: 84% (4+65+15%) PHAs: 87% (18+63+6%) PBDEs: 94% (80+11+3%) % for Bag filter, BTF and PC, respectively TVOC: 48-920 μg/m3 PHAs: 0.94-1.2 μg/m3 PBDEs: 0.85-4.8 μg/m3 (Chen et al., 2016) 666 Table 4. Performance of biological technologies for the removal of VOCs. 667 40 Phytoremediation is an established method for the treatment of polluted soils and waters. The 668 application of botanical systems to indoor environments has been shown effective for removing 669 VOCs and PM (Liu et al., 2007; Pacheco-Torgal et al., 2015; Torpy et al., 2014; Wood et al., 670 2006; Yang et al., 2009). Botanical technologies can be divided into passive (e.g. potted plants) 671 or active (plant-based biotrickling filters, PBTFs) systems. Passive systems rely on the diffusion 672 of gas pollutants, which is a slow process at the low concentrations typically present in indoor 673 environments. Active systems incorporate mechanical ventilation devices to increase the 674 availability of the gas pollutants. In PBTFs, the polluted air is forced to flow though the aerial 675 parts and roots of hydroponic plants to maximize the removal of pollutants. Additional benefits 676 of these active systems such as decreasing indoor temperature, increasing relative humidity or 677 acting as passive acoustic insulation have been identified (Moya et al., 2019). While CO2, SOx, 678 NOx and O3 appear to be taken up directly through the stomates of plants during daylight, VOCs 679 are mostly degraded by microorganisms present in the rhizosphere. A symbiotic relationship 680 between plants and microorganisms may be achieved (Moya et al., 2019; Oh et al., 2011; 681 Pacheco-Torgal et al., 2015; Torpy et al., 2014; Yang et al., 2009). The performance of 682 botanical technologies is still lower than that of other conventional technologies (Table 4). 683 Alike phytoremediation, biofiltration is a well-known and proven method for the removal of 684 gas pollutants, which can be engineered in multiple configurations (Figure 3). In biofilters 685 (BFs), microorganisms are immobilized in a packing media, traditionally an organic material 686 like compost, irrigation is intermittent, and moisture and nutrients are retained by the biofilm 687 and the packing media. BFs are the preferred option for the treatment of hydrophobic pollutants 688 based on the occurrence of a direct contact between the biofilm and the air emission. 689 Bioscrubbers consist of two separate units, where pollutants are initially transferred in a packed-690 bed or mist absorption unit from the gas phase to an aqueous phase, which is recirculated to a 691 second unit where microorganisms growing in suspension biodegrade the dissolved pollutants. 692 This configuration provides high abatement efficiencies for hydrophilic pollutants. Biotrickling 693 41 filters (BTFs) are stand-alone units with packing media, typically inorganic materials with large 694 surface area supporting biofilm growth, with a solution of nutrients continuously trickling down 695 over the packing. BTFs are effective for the treatment of hydrophilic pollutants and typically 696 operate at lower gas residence time than BF or bioscrubbers (Soreanu, 2016; Soreanu and 697 Dumont, 2020). These systems are well-established technologies for air pollution control in 698 many industrial applications, providing an effective abatement performance, reliability and low 699 operating costs (Estrada et al., 2011; Kennes and Veiga, 2013; Soreanu and Dumont, 2020; Van 700 Groenestijn and Kraakman, 2005). Table 4 highlights the performance of BFs and BTFs 701 operating at the concentration range commonly found in indoor air. Removal efficiencies higher 702 than 95 % at gas residence times lower than 95 s have been reported in BFs and BTFs for a 703 wide range of pollutants. 704 Membrane bioreactors are based on the separation of gas and liquid phase by a membrane. A 705 nutrient solution, containing the pollutant degrading microorganisms, is continuously 706 recirculated at one side of the membrane, while the contaminated air flows (usually counter-707 currently) on the other side. An attached biofilm might be formed on the aqueous side of the 708 membrane. The pollutants diffuse from the gas side through the membrane and are biodegraded 709 by the microorganisms in the biofilm or in the bulk cultivation medium (Soreanu and Dumont, 710 2020). Despite exhibiting high investment costs, membrane bioreactors bring some innovations 711 in the field of indoor air purification. First, the air stream and microorganisms in liquid phase 712 are physically separated, which allows a better control of operational conditions, including 713 biofilm thickness and nutrient supply, and prevents the drying of the biofilm. Secondly, the risk 714 of an undesired stripping of microorganisms is avoided and the excess of humidity in the 715 purified air is limited. Finally, the mass-transfer of gas pollutants is improved due to the affinity 716 and permeability of the membrane, especially in the case of hydrophobic pollutants (Kumar et 717 al., 2008; Studer and von Rohr, 2008). Membrane bioreactors have been tested for the treatment 718 of high VOC concentration, and their performance in indoor air applications remains 719 48 Du, L., Batterman, S., Godwin, C., Rowe, Z., Chin, J.Y., Godwin, C., Rowe, Z., Chin, J.Y., 856 2015. Air exchange rates and migration of VOCs in basements and residences. Indoor Air 857 25, 598–609. https://doi.org/10.1111/ina.12178 858 Edwards, R.D., Jurvelin, J., Saarela, K., Jantunen, M.J., 2001. VOC concentrations measured 859 in personal samples and residential indoor, outdoor and workplace microenvironments in 860 EXPOLIS-Helsinki, Finland. Atmos. Environ. 35, 4531–4543. 861 https://doi.org/10.1016/S1352-2310(01)00230-8 862 Estrada, J.M., Kraakman, N.J.R.B., Muñoz, R., Lebrero, R., 2011. A comparative analysis of 863 odour treatment technologies in wastewater treatment plants. Environ. Sci. Technol. 45, 864 1100–1106. https://doi.org/10.1021/es103478j 865 EU Council, 2008. COUNCIL DIRECTIVE 1976L0769. 866 European Comission, 2003. Indoor air pollution: new EU research reveals higher risks than 867 previously thought, European Comission. 868 European Environment Agency, 2017. Air quality in Europe — 2017 report. 869 https://doi.org/10.2800/850018 870 European Environment Agency, 2013. Air quality in Europe—2013 Report: EEA report no 871 9/2013, European Union. https://doi.org/10.2800/92843 872 European Environmental Agency, 2019. Air quality in Europe — 2019 report. 873 https://doi.org/10.2800/822355 874 European Parliament, 2010. DIRECTIVE 2010/31/EU, Official Journal of the European Union. 875 Feng, S., Li, D., Low, Z., Liu, Z., Zhong, Z., Hu, Y., Wang, Y., Xing, W., 2017. ALD-seeded 876 hydrothermally-grown Ag/ZnO nanorod PTFE membrane as efficient indoor air filter. J. 877 Memb. Sci. 531, 86–93. https://doi.org/10.1016/j.memsci.2017.02.042 878 Gall, E.T., Corsi, R.L., Siegel, J.A., 2011. Barriers and opportunities for passive removal of 879 indoor ozone. Atmos. Environ. 45, 3338–3341. 880 https://doi.org/10.1016/j.atmosenv.2011.03.032 881 49 Geiss, O., Giannopoulos, G., Tirendi, S., Barrero-Moreno, J., Larsen, B.R., Kotzias, D., 2011. 882 The AIRMEX study - VOC measurements in public buildings and schools/kindergartens 883 in eleven European cities: Statistical analysis of the data. Atmos. Environ. 45, 3676–3684. 884 https://doi.org/10.1016/j.atmosenv.2011.04.037 885 Guieysse, B., Hort, C., Platel, V., Munoz, R., Ondarts, M., Revah, S., 2008. Biological 886 treatment of indoor air for VOC removal: Potential and challenges. Biotechnol. Adv. 26, 887 398–410. https://doi.org/10.1016/j.biotechadv.2008.03.005 888 Guyot, G., Sherman, M.H., Walker, I.S., 2018. Smart ventilation energy and indoor air quality 889 performance in residential buildings: A review. Energy Build. 165, 416–430. 890 https://doi.org/10.1016/j.enbuild.2017.12.051 891 Harriman, L., Stephens, B., Brennan, T., 2019. New guidance for residential air cleaners. 892 ASHRAE J. 61, 14–23. 893 Héquet, V., Raillard, C., Debono, O., Thévenet, F., Locoge, N., Le Coq, L., 2018. 894 Photocatalytic oxidation of VOCs at ppb level using a closed-loop reactor: The mixture 895 effect. Appl. Catal. B Environ. 226, 473–486. 896 https://doi.org/10.1016/j.apcatb.2017.12.041 897 Hort, C., Platel, V., Sochard, S., Luengas Munoz, A.T., Ondarts, M., Reguer, A., Barona, A., 898 Elias, A., 2014. A hybrid biological process of indoor air treatment for toluene removal. J. 899 Air Waste Manag. Assoc. 64, 1403–1409. https://doi.org/10.1080/10962247.2014.958622 900 Hubbard, H.F., Coleman, B.K., Sarwar, G., Corsi, R.L., 2005. Effects of an ozone-generating 901 air purifier on indoor secondary particles in three residential dwellings. Indoor Air 15, 902 432–444. https://doi.org/10.1111/j.1600-0668.2005.00388.x 903 INSHT, 2015. Guía técnica para la evaluación y prevención de los riesgos relativos a la 904 utilización de los lugares de tra? bajo, Boletín Oficial del Estado. 905 Jantunen, M., Oliveira, E.F., Carrer, P., Kephalopoulos, S., 2011. Promoting actions for healthy 906 indoor air (IAIAQ), European Commission Directorate General for Health and 907 50 Consumers. Luxembourg. https://doi.org/10.2772/61352 908 Jantunen, M.J., Katsouyanni, K., Knöppel, H., Kuenzli, N., Lebret, E., Maroni, M., Saarela, K., 909 Srám, R., Zmirou, D., 1998. Air pollution exposure in European cities: The “EXPOLIS” 910 study. 911 Jo, W.K., Yang, C.H., 2009. Granular-activated carbon adsorption followed by annular-type 912 photocatalytic system for control of indoor aromatic compounds. Sep. Purif. Technol. 66, 913 438–442. https://doi.org/10.1016/j.seppur.2009.02.014 914 Kadribegovic, R., Ekberg, L., Gilligan, A., Shi, B., 2011. Air cleaning by photo catalytic 915 oxidation: An experimental performance test. ASHRAE Trans. 117, 426–433. 916 Kennes, C., Veiga, M.C., 2013. Air Pollution Prevention and Control Air Pollution Prevention 917 and Control Bioreactors and Bioenergy. https://doi.org/10.1002/9781118523360 918 Kim, K.J., Ahn, H.G., 2012. The effect of pore structure of zeolite on the adsorption of VOCs 919 and their desorption properties by microwave heating. Microporous Mesoporous Mater. 920 152, 78–83. https://doi.org/10.1016/j.micromeso.2011.11.051 921 Kotzias, D., Geiss, O., Tirendi, S., Josefa, B.M., Reina, V., Gotti, A., Cimino-Reale, G., Casati, 922 B., Marafante, E., Sarigiannis, D., 2009. Exposure to multiple air contaminants in public 923 buildings, schools and kindergartens-the European indoor air monitoring and exposure 924 assessment (AIRMEX) study. Fresenius Environ. Bull. 18, 670–681. 925 Kotzias, D., Koistinen, K., Kephalopoulos, S., Schlitt, C., Carrer, P., Maroni, M., Jantunen, 926 M.J., Cochet, C., Kirchner, S., Lindvall, T., Mclaughlin, J., Mølhave, L., de Oliveira 927 Fernandes, E., Seifert, B., 2005. The INDEX project. Critical Appraisal of the Setting and 928 Implementation of Indoor Exposure Limits in the EU. Ispra (Italy). 929 Kraakman, N.J.R., Rocha-Rios, J., Van Loosdrecht, M.C.M., 2011. Review of mass transfer 930 aspects for biological gas treatment. Appl. Microbiol. Biotechnol. 91, 873–886. 931 https://doi.org/10.1007/s00253-011-3365-5 932 Kreutzer, M.T., Kapteijn, F., Moulijn, J.A., Ebrahimi, S., Kleerebezem, R., Van Loosdrecht, 933 51 M.C.M., 2005a. Monoliths as biocatalytic reactors: Smart gas-liquid contacting for process 934 intensification. Ind. Eng. Chem. Res. 44, 9646–9652. https://doi.org/10.1021/ie050286m 935 Kreutzer, M.T., Kapteijn, F., Moulijn, J.A., Heiszwolf, J.J., 2005b. Multiphase monolith 936 reactors: Chemical reaction engineering of segmented flow in microchannels. Chem. Eng. 937 Sci. 60, 5895–5916. https://doi.org/10.1016/j.ces.2005.03.022 938 Kumar, A., Dewulf, J., Van Langenhove, H., 2008. Membrane-based biological waste gas 939 treatment. Chem. Eng. J. 136, 82–91. https://doi.org/10.1016/j.cej.2007.06.006 940 Kumar, P., Martani, C., Morawska, L., Norford, L., Choudhary, R., Bell, M., Leach, M., 2016. 941 Indoor air quality and energy management through real-time sensing in commercial 942 buildings. Energy Build. 111, 145–153. https://doi.org/10.1016/j.enbuild.2015.11.037 943 Langer, S., Bekö, G., Bloom, E., Widheden, A., Ekberg, L., 2015. Indoor air quality in passive 944 and conventional new houses in Sweden. Build. Environ. 93, 92–100. 945 https://doi.org/10.1016/j.buildenv.2015.02.004 946 Lebrero, R., Gondim, A.C., Pérez, R., García-Encina, P.A., Muñoz, R., 2014. Comparative 947 assessment of a biofilter, a biotrickling filter and a hollow fiber membrane bioreactor for 948 odor treatment in wastewater treatment plants. Water Res. 49, 339–350. 949 https://doi.org/10.1016/j.watres.2013.09.055 950 Lebrero, R., Rodríguez, E., García-Encina, P.A., Muñoz, R., 2011. A comparative assessment 951 of biofiltration and activated sludge diffusion for odour abatement. J. Hazard. Mater. 190, 952 622–630. https://doi.org/10.1016/j.jhazmat.2011.03.090 953 Lebrero, R., Volckaert, D., Pérez, R., Muñoz, R., Van Langenhove, H., 2013. A membrane 954 bioreactor for the simultaneous treatment of acetone, toluene, limonene and hexane at trace 955 level concentrations. Water Res. 47, 2199–2212. 956 https://doi.org/10.1016/j.watres.2013.01.041 957 Leung, D.Y.C., 2015. Outdoor-indoor air pollution in urban environment: Challenges and 958 opportunity. Front. Environ. Sci. 2, 1–7. https://doi.org/10.3389/fenvs.2014.00069 959 52 Liang, Y., Wu, Y., Sun, K., Chen, Q., Shen, F., Zhang, J., Yao, M., Zhu, T., Fang, J., 2012. 960 Rapid inactivation of biological species in the air using atmospheric pressure nonthermal 961 plasma. Environ. Sci. Technol. 46, 3360–3368. https://doi.org/10.1021/es203770q 962 Liu, Y.J., Mu, Y.J., Zhu, Y.G., Ding, H., Crystal Arens, N., 2007. Which ornamental plant 963 species effectively remove benzene from indoor air? Atmos. Environ. 41, 650–654. 964 https://doi.org/10.1016/j.atmosenv.2006.08.001 965 López De León, L.R., Deaton, K.E., Deshusses, M.A., 2019. Miniaturized Biotrickling Filters 966 and Capillary Microbioreactors for Process Intensification of VOC Treatment with 967 Intended Application to Indoor Air. Environ. Sci. Technol. 53, 1518–1526. 968 https://doi.org/10.1021/acs.est.8b05209 969 Lu, N., Pei, J., Zhao, Y., Qi, R., Liu, J., 2012. Performance of a biological degradation method 970 for indoor formaldehyde removal. Build. Environ. 57, 253–258. 971 https://doi.org/10.1016/j.buildenv.2012.05.007 972 Luengas, A., Barona, A., Hort, C., Gallastegui, G., Platel, V., Elias, A., 2015. A review of 973 indoor air treatment technologies. Rev. Environ. Sci. Biotechnol. 14, 499–522. 974 https://doi.org/10.1007/s11157-015-9363-9 975 Luengas, A.T., Hort, C., Platel, V., Elias, A., Barona, A., Moynault, L., 2017. Removal of traces 976 of toluene and p-xylene in indoor air using biofiltration and a hybrid system (biofiltration 977 + adsorption). Environ. Sci. Pollut. Res. 24, 10674–10684. 978 https://doi.org/10.1007/s11356-017-8689-y 979 Mandin, C., Trantallidi, M., Cattaneo, A., Canha, N., Mihucz, V.G., Szigeti, T., Mabilia, R., 980 Perreca, E., Spinazzè, A., Fossati, S., De Kluizenaar, Y., Cornelissen, E., Sakellaris, I., 981 Saraga, D., Hänninen, O., De Oliveira Fernandes, E., Ventura, G., Wolkoff, P., Carrer, P., 982 Bartzis, J., 2017. Assessment of indoor air quality in office buildings across Europe – The 983 OFFICAIR study. Sci. Total Environ. 579, 169–178. 984 https://doi.org/10.1016/j.scitotenv.2016.10.238 985 53 Marć, M., Śmiełowska, M., Namieśnik, J., Zabiegała, B., 2018. Indoor air quality of everyday 986 use spaces dedicated to specific purposes—a review. Environ. Sci. Pollut. Res. 25, 2065–987 2082. https://doi.org/10.1007/s11356-017-0839-8 988 Mendoza, J.L., Granados, M.R., de Godos, I., Acién, F.G., Molina, E., Heaven, S., Banks, C.J., 989 2013. Oxygen transfer and evolution in microalgal culture in open raceways. Bioresour. 990 Technol. 137, 188–195. https://doi.org/10.1016/j.biortech.2013.03.127 991 Mo, J., Zhang, Y., Xu, Q., Lamson, J.J., Zhao, R., 2009. Photocatalytic purification of volatile 992 organic compounds in indoor air: A literature review. Atmos. Environ. 43, 2229–2246. 993 https://doi.org/10.1016/j.atmosenv.2009.01.034 994 Moya, T.A., van den Dobbelsteen, A., Ottelé, M., Bluyssen, P.M., 2019. A review of green 995 systems within the indoor environment. Indoor Built Environ. 28, 298–309. 996 https://doi.org/10.1177/1420326X18783042 997 Muñoz, R., Daugulis, A.J., Hernández, M., Quijano, G., 2012. Recent advances in two-phase 998 partitioning bioreactors for the treatment of volatile organic compounds. Biotechnol. Adv. 999 30, 1707–1720. https://doi.org/10.1016/j.biotechadv.2012.08.009 1000 Niederwieser, T., 2015. Evaluation of a flow-through test bed for algal atmosphere 1001 revitalization in spaceflight applications. Aerosp. Eng. Sci. Grad. Theses Diss. 139. 1002 Oh, G.S., Jung, G.J., Seo, M.H., Im, Y. Bin, 2011. Experimental study on variations of CO2 1003 concentration in the presence of indoor plants and respiration of experimental animals. 1004 Hortic. Environ. Biotechnol. 52, 321–329. https://doi.org/10.1007/s13580-011-0169-6 1005 Pacheco-Torgal, F., Labrincha, J.A., Diamanti, M. V., Yu, C.P., Lee, H.K., 2015. 1006 Biotechnologies and biomimetics for civil engineering, Biotechnologies and Biomimetics 1007 for Civil Engineering. https://doi.org/10.1007/978-3-319-09287-4 1008 Pokhrel, A.K., Bates, M.N., Acharya, J., Valentiner-branth, P., Chandyo, R.K., Shrestha, P.S., 1009 Raut, A.K., Smith, K.R., 2015. PM 2.5 in household kitchens of Bhaktapur, Nepal, using 1010 four different cooking fuels. Atmos. Environ. 113, 159–168. 1011 54 https://doi.org/10.1016/j.atmosenv.2015.04.060 1012 Polidori, A., Fine, P.M., White, V., Kwon, P.S., 2013. Pilot study of high-performance air 1013 filtration for classroom applications. Indoor Air 23, 185–195. 1014 https://doi.org/10.1111/ina.12013 1015 Prasauskas, T., Martuzevicius, D., Kalamees, T., Kuusk, K., Leivo, V., Haverinen-1016 Shaughnessy, U., 2016. Effects of Energy Retrofits on Indoor Air Quality in Three 1017 Northern European Countries. Energy Procedia 96, 253–259. 1018 https://doi.org/10.1016/j.egypro.2016.09.134 1019 Rocha-Rios, J., Kraakman, N.J.R., Kleerebezem, R., Revah, S., Kreutzer, M.T., van 1020 Loosdrecht, M.C.M., 2013. A capillary bioreactor to increase methane transfer and 1021 oxidation through Taylor flow formation and transfer vector addition. Chem. Eng. J. 217, 1022 91–98. https://doi.org/10.1016/j.cej.2012.11.065 1023 Rösch, C., Kohajda, T., Röder, S., von Bergen, M., Schlink, U., 2014. Relationship between 1024 sources and patterns of VOCs in indoor air. Atmos. Pollut. Res. 5, 129–137. 1025 https://doi.org/10.5094/APR.2014.016 1026 Roso, M., Falcomer, D., Azzano, A., Boaretti, C., Donadini, R., Lorenzetti, A., Modesti, M., 1027 2019. Design and development of nanostructured filter media for VOCs abatement in 1028 closed environments. J. Environ. Chem. Eng. 7, 103045. 1029 https://doi.org/10.1016/j.jece.2019.103045 1030 Royal College of Physicians, 2016. Every breath we take: the lifelong impact of air pollution. 1031 Report of a working party. London. 1032 Satish, U., Mendell, M.J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., Fisk, W.J., 2012. 1033 Concentrations on Human Decision-Making Performance. Environ. Health Perspect. 120, 1034 1671–1678. https://doi.org/10.1289/ehp.1104789 1035 Saucedo-Lucero, J.O., Revah, S., 2018. Monitoring key organic indoor pollutants and their 1036 elimination in a biotrickling biofilter. Environ. Sci. Pollut. Res. 25, 9806–9816. 1037 55 https://doi.org/10.1007/s11356-018-1274-1 1038 SCHER, 2007. Opinion on risk assessment on indoor air quality. 1039 Sidhu, M.K., Ravindra, K., Mor, S., John, S., 2017. Household air pollution from various types 1040 of rural kitchens and its exposure assessment. Sci. Total Environ. 586, 419–429. 1041 https://doi.org/10.1016/j.scitotenv.2017.01.051 1042 Singh, D., Kumar, A., Kumar, K., Singh, B., Mina, U., Singh, B.B., Jain, V.K., 2016. Statistical 1043 modeling of O3, NOx, CO, PM2.5, VOCs and noise levels in commercial complex and 1044 associated health risk assessment in an academic institution. Sci. Total Environ. 572, 586–1045 594. https://doi.org/10.1016/j.scitotenv.2016.08.086 1046 Soreanu, G., 2016. Biotechnologies for improving indoor air quality, in: Start-Up Creation: The 1047 Smart Eco-Efficient Built Environment. Elsevier Ltd, pp. 301–328. 1048 https://doi.org/10.1016/B978-0-08-100546-0.00012-1 1049 Soreanu, G., Dumont, É., 2020. From Biofiltration to Promising Options in Gaseous Fluxes 1050 Biotreatment. Recent Developments, New Trends, Advances, and Opportunities. 1051 https://doi.org/10.1016/c2018-0-03712-3 1052 Srivastava, I., Singh, P.K., Gupta, T., Sankararamakrishnan, N., 2019. Preparation of 1053 mesoporous carbon composites and its highly enhanced removal capacity of toxic 1054 pollutants from air. J. Environ. Chem. Eng. 7, 103271. 1055 https://doi.org/10.1016/j.jece.2019.103271 1056 Studer, M., von Rohr, R., 2008. Novel Membrane Bioreactor: Able to Cope With Fluctuating 1057 Loads, Poorly Water Soluble VOCs, and Biomass Accumulation. Biotechnol. Bioeng. 99, 1058 38–48. https://doi.org/10.1002/bit.21532 1059 Sung, J.H., Kim, M., Kim, Y.J., Han, B., Hong, K.J., Kim, H.J., 2019. Ultrafine particle 1060 cleaning performance of an ion spray electrostatic air cleaner emitting zero ozone with 1061 diffusion charging by carbon fiber. Build. Environ. 166, 106422. 1062 https://doi.org/10.1016/j.buildenv.2019.106422 1063 56 Tang, X., Wei, J., Kong, Z., Zhang, H., Tian, J., 2020. Introduction of amino and rGO into PP 1064 nonwoven surface for removal of gaseous aromatic pollutants and particulate matter from 1065 air. Appl. Surf. Sci. 511, 145631. https://doi.org/10.1016/j.apsusc.2020.145631 1066 Torpy, F., Clements, N., Pollinger, M., Dengel, A., Mulvihill, I., He, C., Irga, P., 2018. Testing 1067 the single-pass VOC removal efficiency of an active green wall using methyl ethyl ketone 1068 (MEK). Air Qual. Atmos. Heal. 11, 163–170. https://doi.org/10.1007/s11869-017-0518-4 1069 Torpy, F.R., Irga, P.J., Burchett, M.D., 2014. Profiling indoor plants for the amelioration of 1070 high CO2 concentrations. Urban For. Urban Green. 13, 227–233. 1071 https://doi.org/10.1016/j.ufug.2013.12.004 1072 Tran, T.V., Dang, N.T., Chung, W.Y., 2017. Battery-free smart-sensor system for real-time 1073 indoor air quality monitoring. Sensors Actuators, B Chem. 248, 930–939. 1074 https://doi.org/10.1016/j.snb.2017.01.198 1075 US Environmental Protection Agency, 1995. The Inside Story : A Guide to Indoor Air Quality. 1076 EPA Doc. # 402-K-93-007. 1077 Van Durme, J., Dewulf, J., Demeestere, K., Leys, C., Van Langenhove, H., 2009. Post-plasma 1078 catalytic technology for the removal of toluene from indoor air: Effect of humidity. Appl. 1079 Catal. B Environ. 87, 78–83. https://doi.org/10.1016/j.apcatb.2008.08.015 1080 Van Groenestijn, J.W., Kraakman, N.J.R., 2005. Recent developments in biological waste gas 1081 purification in Europe. Chem. Eng. J. 113, 85–91. 1082 https://doi.org/10.1016/j.cej.2005.03.007 1083 Vasile, V., Petran, H., Dima, A., Petcu, C., 2016. Indoor Air Quality - A Key Element of the 1084 Energy Performance of the Buildings. Energy Procedia 96, 277–284. 1085 https://doi.org/10.1016/j.egypro.2016.09.150 1086 Verma, V.K., Subbiah, S., Kota, S.H., 2019. Sericin-coated polyester based air-filter for 1087 removal of particulate matter and volatile organic compounds (BTEX) from indoor air. 1088 Chemosphere 237, 124462. https://doi.org/10.1016/j.chemosphere.2019.124462 1089 57 Wang, N., Raza, A., Si, Y., Yu, J., Sun, G., Ding, B., 2013. Tortuously structured polyvinyl 1090 chloride/polyurethane fibrous membranes for high-efficiency fine particulate filtration. J. 1091 Colloid Interface Sci. 398, 240–246. https://doi.org/10.1016/j.jcis.2013.02.019 1092 Wang, Z., Pei, J., Zhang, J.S., 2014. Experimental investigation of the formaldehyde removal 1093 mechanisms in a dynamic botanical filtration system for indoor air purification. J. Hazard. 1094 Mater. 280, 235–243. https://doi.org/10.1016/j.jhazmat.2014.07.059 1095 Wei, W., Ramalho, O., Mandin, C., 2015. Indoor air quality requirements in green building 1096 certifications. Build. Environ. 92, 10–19. https://doi.org/10.1016/j.buildenv.2015.03.035 1097 WHO Regional Office for Europe, 2015. Economic cost of the health impact of air pollution in 1098 Europe: Clean air, health and wealth. 1099 Wilkinson, S., Stoller, P., Ralph, P., Hamdorf, B., Catana, L.N., Kuzava, G.S., 2017. Exploring 1100 the Feasibility of Algae Building Technology in NSW. Procedia Eng. 180, 1121–1130. 1101 https://doi.org/10.1016/j.proeng.2017.04.272 1102 Wood, R.A., Burchett, M.D., Alquezar, R., Orwell, R.L., Tarran, J., Torpy, F., 2006. The 1103 potted-plant microcosm substantially reduces indoor air VOC pollution: I. Office field-1104 study. Water. Air. Soil Pollut. 175, 163–180. https://doi.org/10.1007/s11270-006-9124-z 1105 World Bank, Institute for Health Metrics and Evaluation, 2016. The Cost of Air Pollution: 1106 Strengthening the Economic Case for Action. Washington, DC. 1107 World Health Organization, 2016. Ambient Air Pollution: A global assessment of exposure and 1108 burden of disease. 1109 World Health Organization, 2014. Burden of disease from Household Air Pollution for 2012. 1110 World Health Organization, WHO Regional Office for Europe, 2010. WHO guidelines for 1111 indoor air quality: selected pollutants. 1112 Xu, J., Szyszkowicz, M., Jovic, B., Cakmak, S., Austin, C.C., Zhu, J., 2016. Estimation of 1113 indoor and outdoor ratios of selected volatile organic compounds in Canada. Atmos. 1114 Environ. 141, 523–531. https://doi.org/10.1016/j.atmosenv.2016.07.031 1115