scieee AI-readable full text Open interactive document viewer

Review of multiport power converters for distribution network applications

Harrison, Sam,Soltoswski, Bartosz,Pepiciello, Antonio,Henao Muñoz, Andrés Camilo,Y. Farag, Ahmed,Beza, Mebtu,Xu, Lie,Egea Àlvarez, Agustí,Cheah Mañé, Marc,Gomis Bellmunt, Oriol

Abstract

Multiport power converters integrate three or more energy devices into a single (potentially highly controllable and efficient) hub. These characteristics suggest that multiport power converters may be valuable for the decarbonisation of distribution networks, where the increase of converter-interfaced devices has degraded system reliability and efficiency. This review analyses the suitability of a wide range of multiport power converter solutions for four example distribution network applications (where previous studies have focussed on a limited range of topologies or applications) and the research areas that can progress their maturity. A review of grid codes and standards overviews the base capability that multiport power converters are likely to require, some of which are carried forward as requirements for a novel comparison tool. The comparison tool is developed to qualify and score reviewed topologies in terms of a range of features that are weighted for the applications. Isolated and partially-isolated topologies perform well due to their flexibility to be configured for the specifications and their operational capabilities (including modularity and voltage decoupling). Further research should focus on the complex control interactions between ports and scaling of these topologies for medium voltages. In contrast, many direct current non-isolated topologies do not qualify due to their low flexibility to be configured for the applications. This suggests that future research could focus on the development of a more flexible non-isolated multiport power converter configuration to take advantage of the high efficiency and low footprint that these topologies might otherwise offer for low voltage applications.

Full text

Renewable and Sustainable Energy Reviews 203 (2024) 114742 Available online 13 July 2024 1364-0321/© 2024 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). Review of multiport power converters for distribution network applications Sam Harrison a , * , Bartosz Soltoswski a , Antonio Pepiciello b , Andres Camilo Henao b , Ahmed Y. Farag c , Mebtu Beza d , Lie Xu a , Agustí Egea-` Alvarez a , Marc Cheah-Ma˜ n´ e e , Oriol Gomis-Bellmunt e a Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow, UK b Catalonia Institute for Energy Research (IREC), Jardins de les Dones de Negre 1, Sant Adria de Besos, 08930, Barcelona, Spain c Department of Management and Engineering (DTG), University of Padova, 36100, Vicenza, Italy d Department of Electrical Engineering, Division of Electric Power Engineering, Chalmers University of Technology, Gothenburg, Sweden e Centre d’Innovaci´ o Tecnol` ogica en Convertidors Est` atics i Accionamients (CITCEA-UPC), Department d’Enginyeria El` ectrica, Universitat Polit` ecnica de Catalunya, UPC. Av. Diagonal 647, Pl. 2, 08028, Barcelona, Spain ARTICLE INFO Keywords: Multiport power converter Distribution network Low-carbon building Microgrid Renewable energy source Energy storage system Electric vehicle ABSTRACT Multiport power converters integrate three or more energy devices into a single (potentially highly controllable and efficient) hub. These characteristics suggest that multiport power converters may be valuable for the decarbonisation of distribution networks, where the increase of converter-interfaced devices has degraded system reliability and efficiency. This review analyses the suitability of a wide range of multiport power converter solutions for four example distribution network applications (where previous studies have focussed on a limited range of topologies or applications) and the research areas that can progress their maturity. A review of grid codes and standards overviews the base capability that multiport power converters are likely to require, some of which are carried forward as requirements for a novel comparison tool. The comparison tool is developed to qualify and score reviewed topologies in terms of a range of features that are weighted for the applications. Isolated and partially-isolated topologies perform well due to their flexibility to be configured for the specifications and their operational capabilities (including modularity and voltage decoupling). Further research should focus on the complex control interactions between ports and scaling of these topologies for medium voltages. In contrast, many direct current non-isolated topologies do not qualify due to their low flexibility to be configured for the applications. This suggests that future research could focus on the development of a more flexible nonisolated multiport power converter configuration to take advantage of the high efficiency and low footprint that these topologies might otherwise offer for low voltage applications. Abbreviations AC Alternating current MVG Maximum voltage gain BD Bidirectional N Number of ports C Class PFC Power-factor correction CLL/LLC Capacitor-inductor-inductor/Inductor-inductor-capacitor PSFB Phase shifted full-bridge PV Photovoltaic D/M/MM/TAB Dual/Multi/Modular multi-/Triple active bridge PWM Pulse-width-modulation RES Renewable energy source D/MT Dual/Multi-transformer RESO Resonance DC Direct current SCAL Scalability DN Distribution network TC Transformer cores (E)SOP (Enhanced) Soft-open point TM Technology maturity (continued on next page) * Corresponding author. E-mail address: [email protected] (S. Harrison). Contents lists available at ScienceDirect Renewable and Sustainable Energy Reviews journal homepage: www.elsevier.com/locate/rser https://doi.org/10.1016/j.rser.2024.114742 Received 12 January 2024; Received in revised form 22 May 2024; Accepted 8 July 2024 Renewable and Sustainable Energy Reviews 203 (2024) 114742 2 1. Introduction The ongoing climate emergency and required decarbonisation is driving an increase in the penetration of power converter-interfaced devices on electric power systems [1]. This increase in power converters is subjecting low voltage (LV) and medium voltage (MV) distribution networks to several issues, as well as some new opportunities. There is a large increase of renewable energy sources (RESs) on distribution networks (DNs) [2]. The low carbon generators are not being utilised optimally due to their low correlation (and uncontrollability) with respect to demand profiles, particularly on radial feeders that can experience significant voltage variations during generation-demand imbalance [3,4]. Enhanced soft-open-points (ESOPs) have been discussed to mitigate this issue and increase low carbon utilisation by interconnecting neighbouring radial feeders, along with any collocated RESs or energy storage systems (ESSs), to enable peak shaving and other grid support functionality [5]. In parallel with the increase of RESs there is an increase of Direct Current (DC) devices such as ESSs and electric vehicle chargers, all of which require conversion stages [6]. These conversion stages affect system costs, space-requirements, and efficiencies. However, the high number of energy sources and sinks also offer the potential for energy aggregation. Residential and facility buildings are examples of these high converter density scenarios that could benefit from the more efficient integration of energy devices with optimised energy utilisation. While there are several issues relating to converter integration to established power systems, a large portion of the developing world remains without access to electricity [7], which can be linked to their constraint in terms of key social-development indices [8]. Some of these communities have the potential to be electrified by RES-based microgrids [9,10]. Technical features that impact the success of remote microgrids include: the reliability of components and the ability of the system to adapt as the community’s needs vary [11]. Multiport power converters (MPCs) offer a solution to integrate multiple energy ports into a single aggregated hub [12]. An illustrative example of a MPC that interfaces six ports (three DC and three Alternating Current (AC)) is pictured in Fig. 1. MPCs are highly controllable, which offers effective energy management across all of their ports while maintaining local requirements such as power quality and grid stability [13,14]. These characteristics suggest that MPCs may offer valuable solutions to the DN issues with a reduced number of conversion stages compared to conventional AC and DC multi-terminal converter solutions, which may translate to a higher cost-efficiency and power density [15–17]. MPCs have been studied to improve the cost-efficiency of LV applications such as the integration of converter interfaced devices in residential buildings [15,18]. However, more advanced topologies with greater functionality and the ability to integrate a wider range of voltages are also being explored [19]. Several reviews of MPCs for these different applications exist but they often focus on individual applications (e.g. Refs. [20–23]) or individual topology families (e.g. Refs. [13, 24,25,26]). Furthermore, most reviews fail to make a quantitative comparison. This study aims to offer a fundamental overview of the characteristics that MPCs will be required to possess and the features that make different topologies suitable for low and medium voltage applications. The wide comparison is implemented to identify research paths for the advancement of MPC maturity. A quantitative comparison tool is developed to enable meaningful comparison of the widely different topologies for four specific applications. Such an approach has not previously been achieved, as shown by Table 1, which overviews the existing works and their relation to the different contributions of this review. The main contributions of this review are: •An outline of the fundamental technical and safety requirements that MPCs are expected to be subject to and hence the baseline capability they will need to possess for DN applications. o Suggestions are also made for the potential configuration of MPC standards considering their significantly different operating principles compared to conventional converter devices. •A review of the features of a wide range of MPC topologies including considerations for MV applications. •The development of a high-level Pugh Matrix comparison tool to identify the suitability of the reviewed MPC topology characteristics for a set of DN applications. •The identification of future research pathways to develop the maturity of MPCs for these DN applications. 2. Grid codes and requirements for multiport power converters An overview of grid codes, technical, and safety standards relevant to the design and operation of LV and MV MPCs is presented here to identify the baseline capability that they will be expected to possess. The requirements for the converter-interfaced devices that will be integrated by MPCs are discussed as there are no existing MPC standards. The key requirements identified in this Section will be carried forward for the assessment of suitable MPC topologies. 2.1. Review of grid codes and standards Safety standards for a range of LV and MV converters and electrical equipment [27–32] define the range of hazards and the conditions of Fig. 1. Illustrative example of a multiport power converter (MPC) solution for an example six port application. (continued) ESS Energy storage system UPFC Unified Power Flow Controller ISO Isolated UPQC Unified Power Quality Conditioner L/M/ULV Low/Medium/Ultra-low voltage MF Medium frequency UPS Uninterruptible power supply MOD Modularity VD Voltage decoupling MPC Multiport power converter VSC Voltage source converter S. Harrison et al. Renewable and Sustainable Energy Reviews 203 (2024) 114742 3 operation that the hazards must be avoided in. Particularly relevant to MPCs is the information relating to equipment with multiple sources of supply [27–29]. These devices are required to ensure that neither the incorrect plugging of supplies nor the operation during normal or single faulted conditions result in hazards due to the multiple sources. Some design considerations are also introduced, including: the prevention of voltage back-feed (which can be achieved using isolation), protection against unintentional islanding, potentially high touch current levels due to the passing of energy between sources, and damage to wiring. For the connection to AC DNs, grid codes historically required the provision of basic functionality to maintain the grid’s satisfactory operation, such as power factor control [33,34], power quality requirements [34,35], and grounding requirements [36,37]. However, DN requirements increasingly include advanced functionality, such as reactive current support [38,39], active power injections for frequency support [34,40], and the definition of islanded capabilities [37,41]. MPCs will likely need to possess all of this functionality due to their key role for grid support and as an integration hub for multiple energy sources and sinks. AC grid connection requirements are framed in terms of the minimum capability of the given energy source, which enables the system operator to have some confidence that the device will maintain acceptable operation throughout its lifetime. Most prosumer devices (such as ESSs [34], interconnectors [42,43], and bi-directional EVs [44]) are also treated in this way, which is thought to fail to effectively describe their time-varying power flows [45]. Consideration will need to be made for the configuration of requirements for MPCs, which will interface multiple energy sources to potentially multiple networks, and whose minimum capability will be difficult to define. As well as meeting AC DN requirements, MPCs will need to simultaneously maintain the operation of its other ports, similar to a DC collection pool or microgrid [42,45]. These DC network requirements are less widely defined, although an overview is provided in Ref. [45]. The review describes functional requirements including: sufficient DC capacitance, electromagnetic compatibility [46,47], voltage ripple [48], and hold-up time (the period that a DC network should maintain supply to local loads) [49] following a disturbance. The review [45] also highlights the safety standard for LV DC distribution systems [32], which requires galvanic isolation of the high overcurrent and voltage AC DN side from lower current and voltage DC ports. Although other examples of an explicit requirement for converters to achieve galvanic isolation were rare (only the Ecuadorian grid code for solar PV less than 100 kW [50]), a similar need to isolate high overcurrent ports may be necessary in MPCs. 2.2. Considerations for MPCs Some suggestions are made here for the configuration of grid code and safety standards for MPCs considering the review in Section 2.1. Each port will need to meet the standard safety specifications corresponding to its given energy source or sink, as well as making additional efforts to ensure that new hazards are not introduced due to the operation of the other ports. Specific protective procedures will need to be taken between ports with different voltage and current properties, which may resemble the protection zones for DC distribution networks detailed in Ref. [32]. Assuming that the MPC is designed to meet these safety requirements, operational capabilities will need to ensure: 1) the effective operation of the MPC to maintain controllable energy flow and 2) the meeting of grid connection agreements to ensure the MPC does not degrade the stability and power quality of any of the electrical power systems it is connected to. The former capabilities may be related to the DC collection pool requirements detailed in Ref. [45] while the latter will resemble conventional AC DN requirements. Although it will be difficult to define a minimum specification for the MPC at the AC DN connection point, it may be possible to define a minimum capability according to the aggregated energy capacity and characteristics of the Table 1 Overview of MPC research with respect to the objectives of this review. Ref Application(s) Topologies Review of standards Topology assessment framework [20] Integration of LV loads, generation, and storage Hybrid (derived) converters No Compare efficiencies and voltage gain for single application [21] Integration of solar PV and ESS to LV AC DN Non-isolated MPCs No Compare leakage ground current and DC ripple for single case [22] Integration of solar PV and ESS to LV AC DN DC MPCs No Describe necessary power flows and general features of topologies for single application [23] Integration of LV loads, generation, and storage Hybrid (derived) converters No N/a [13] Multi-DC to AC applications at different voltage levels Single-stage multi-DC to AC MPCs No Detailed qualitative discussion of MPC characteristics for several applications [14] Integration of multiple energy sources MPCs No Discussion of key features but no analysis of suitability [24] Integration of RESs Non-isolated DC MPCs No Discussion of required power flows and comparison in terms of component count, complexity, and efficiency [25] RES-based microgrids Partially-isolated DC MPCs Briefly Comparison in terms of component count, functional capability, power and voltage levels, and efficiency This review Converter integration on LV and MV DNs All MPCs Yes High level Pugh Matrix comparison of key features for four specific applications Fig. 2. Potential structure of grid code and safety standard requirements for MPCs with reference to the protection zones defined in Ref. [32]. S. Harrison et al. Renewable and Sustainable Energy Reviews 203 (2024) 114742 4 remaining ports (while also considering any other AC DN connected ports). Fig. 2 depicts the potential MPC grid code and safety standard configuration for an example Facility Building Scenario (S3), which is described in detail in Section 4.1. The protection zones are derived from the standard NPR 9090 [32], which classified combined AC and DC installations (not exceeding 1500 V (DC)) according to their voltage, current, and power levels. The figure highlights the key point between Zones 0 and 1, across which ports must be galvanically isolated. The figure also indicates the definition of the AC DN port’s minimum operational capability according to the aggregation of the remaining ports. Zones 2 to 4 are grouped in Fig. 2 due to their lower voltage and current properties that do not characterise any of the example ports. The protection zones and conditional isolation requirement will be carried forward for the qualification of topologies in the comparison methodology later in this review. 3. Multiport power converter topologies This Section provides an overview of a wide range of existing MPCs that are relevant to DN applications. The literature review is organised according to a classification structure (pictured in Fig. 3) based on the topology of the MPC. Some of the reviews detailed in Table 1 utilise similar classification structures to ease the overviewing and comparison of topology features, however, an exclusive structure (so that all branches are distinct from one another) that encompasses such a wide range of topologies has not been proposed. The classification structure used here separates MPCs initially according to their galvanic isolation, either: non-isolated, where there is no isolation between any ports; isolated, where all ports are isolated from one another; or partiallyisolated, where there is at least one isolated and one non-isolated conversion stage. An additional level of subclasses (C1 to C6) is introduced to further describe topologies and their general features, which are introduced and discussed throughout Sections 3.1 to 3.3. Additional considerations and examples of MPCs for medium and high voltage applications are discussed in Section 3.4. Selected topologies are pictured for each subclass, without specifying the source, load, or prosumer device that may be interfaced at each port (depending on the capability of the given conversion stage). 3.1. Non-isolated multiport power converters The defining feature of non-isolated topologies is the complete lack of an isolating transformer. The configurations can often be simple compared to isolated topologies. Therefore, they can achieve high efficiencies and power densities for the applications they are designed for [22]. However, some of the simple configurations can lack bidirectional flexibility, constraining them to a low number of power flow modes [51], and can be difficult to adapt beyond the number and type of ports they are designed for. The configurations may also lack sufficient capabilities to safely integrate significantly different voltage levels due to the lack of galvanic isolation. Alternatively, multiport configurations of conventional independent converter solutions can be included in the non-isolated class, which offer high technological maturity, operational flexibility, and scalability for higher voltage levels but at the cost of lower power density and efficiency compared to integrated non-isolated solutions. Non-isolated MPCs can be further classified according to their ability to interface either only DC ports or both AC and DC ports without the use of additional conversion stages. 3.1.1. DC capable DC capable non-isolated MPCs are incapable of interfacing AC ports, however, are suggested to be adapted to do so using a cascaded inverter [22]. They are generally built from the interleaving of either simple (e.g. buck or boost) or more complex (e.g. half or full-bridge) fundamental converter cells. These topologies generally use the fewest number of active and passive devices to interface three DC ports and therefore achieve very high efficiencies for these applications. Combined input/output DC converters mesh conventional converter cells, often with the objective of interfacing RESs and ESSs. An example is the combination of a unidirectional boost (to interface a PV port) with a bidirectional buck (to interface an ESS port) to a DC load (as pictured in Fig. 4) [52]. Magnetically or capacitively coupled converters adapt these cell combinations to achieve enhanced voltage boost. For example, two cascaded boost converters are linked using a coupling inductor in Ref. [53]. Resonance can be introduced to this topology by adding an active clamp, which enables soft-switching and the reduction of switching losses. Examples of ultra-low voltage (ULV) three port converters are available on the market for integrated circuit telecoms applications [54, 55] and some LV residential or industrial instrumentation applications [56], however, these examples generally exhibit low bidirectional flexibility. Following the first generations, research has focussed on improving the number of components, efficiency, and operational flexibility of DC capable non-isolated topologies for three port applications [57–59]. 3.1.2. DC and AC capable DC and AC capable non-isolated topologies offer potential improvements in power density for applications that include AC ports, such as the interfacing of DC sources with DC and AC loads. Some configurations offer improved bidirectional flexibility compared to DC only non-isolated topologies, but this can come at the cost of more complex operation. Derived converters, which hybridise conventional cells, were specifically developed to improve the efficiency of applications that serve DC and AC loads compared to multi-stage back-to-back converter configurations. An example, the Boost Derived Hybrid Converter [60], replaces the switch of a boost converter with a full-bridge cell. The configurations offer simple control, compact design, and reduced cost for their designed applications. Although derived converters have been proposed to be interlaced to achieve three phase output [61], or to use additional active and passive devices to increase the voltage gain [62], they do not appear to possess the flexibility to interface significantly different port numbers or types without additional conversion stages. Reconfigurable-port topologies use relays and other slow switching Fig. 3. Proposed MPC classification structure. Fig. 4. Cascaded buck and bidirectional-boost converter [52]. S. Harrison et al. Renewable and Sustainable Energy Reviews 203 (2024) 114742 5 devices to change the connection of standard converter cells and their ports. The simple construction leads to a low number of devices, which enables high efficiencies and power density. However, the slow switching devices can constrain the operational flexibility to transition between power flow modes. An example is the single-stage three-phase reconfigurable converter, which transitions from interfacing either a DC solar PV or ESS to the AC grid, or to each other [63]. An additional example of a DC and AC capable non-isolated MPC is the adapted Unified Power Quality Conditioner (UPQC) that integrates storage or distributed generation on the DC link of a conventional back- to-back voltage source converter (VSC) configuration (as pictured in Fig. 5) [64]. The multiport UPQC is developed from two-port UPQC topologies (otherwise known as the Unified Power Flow Controller (UPFC) [65,66] or Smart Power Bridge [67]) that interface the output of one VSC to the AC network via a series transformer and the other using a conventional parallel connection. UPQC-type converters are studied for distribution [64,65] and transmission network applications [65–68]. Although the configuration can include the use of transformers, it is classified as non-isolated as the transformers are not integrated within the converter topology. Topologies derived from conventional independent converters like the UPQC can benefit from the technological maturity, high controllability, and modularity of the independent converter solutions [69]. UPQC-type topologies were developed so that the series ports could control the AC line voltage and active power flow using a partially rated converter, while the parallel port could compensate the reactive power flow and regulate the bus voltages. Alternative configurations for single- [72,73] and three-phase applications [74] have been proposed, as well as configurations that replace the series connected transformer (which needs to withstand the AC line’s short circuit current and possess a core with sufficient over-excitation tolerance) with three single-phase converters [67,75] or a single modular multilevel converter [64]. The UPQC MPCtopology is particularly interesting as it introduces the additional consideration of the series connection of the output port to the ACnetwork to achieve voltage control, which is different from the series-connection of submodules in multilevel topologies that makes them suitable to support high voltages (discussed in Section 4.2.6). 3.2. Isolated multiport power converters Isolated MPCs use transformers to galvanically isolate every port from one another. As a result of this global isolation, isolated MPCs offer high fault tolerance and voltage gain [76]. Depending on the exact configuration they can offer: modularity, resonance, and simultaneous power transfer between different ports. However, they are non-linear multi-input multi-output systems that have a high degree of coupling between states, which can result in complex modelling, analysis, and control [77]. Compared to non-isolated topologies, isolated MPCs may be able to support an increased number of power flow modes and be more flexible to move between them, particularly when using bidirectional modules [19], but at the cost of lower efficiency, lower power density, and increased complexity. Isolated MPCs are further classified according to the number of windings and transformers that they utilise. 3.2.1. Multi-winding single transformer Multi-winding single transformer isolated MPCs use a separate winding to interface each energy port through a single transformer core. Each winding possesses a DC-AC conversion module, which can result in a high number of active devices (increasing the number of potential points of failure). In general, multi-winding single transformer MPCs are further distinguished according to the resonant ability of their DC-AC conversion modules or based on the symmetry of the port bridge connections on either side of the transformer. Asymmetric configurations (with different bridge coupling on the primary versus secondary sides) offer the ability to reduce the number of switching devices (to reduce the cost and losses) but may only be suitable for specific applications [19]. Non-resonant topologies generally consist of dual active bridge (DAB) conversion modules, which offer effective control of the output voltage and power flow between multiple ports [78] due to their high degree of freedom compared to resonant modules. However, their switching frequency can be constrained by the inversely proportional relationship between the DAB’s power transfer and inductance [79]. Resonant topologies are generally built from series resonant converter components (as pictured in Fig. 6), and can therefore support higher switching frequencies [79]. These topologies are described as being suited for applications where the load is highly variable and therefore requires output voltage regulation [19]. Multi-winding MPCs exhibit mid-level market maturity compared to other configurations, as some MW solutions are available on the market for ULV applications [80], while similar topologies are also beginning to be subject to more advanced testing in industrially relevant power and voltage conditions e.g. Ref. [81]. 3.2.2. Multi-transformer Single winding multi-transformer isolated MPCs continue to interface each energy port with its own winding, however, each input-output winding pair are connected through an independent transformer core. The multiple transformers increase the core material, volume, number of switches, and losses and reduce the fault tolerance (due to the inability to isolate and disconnect the faulty port winding) with respect to multiwinding configurations. Dual-transformer triple active bridge (DT TAB) converters are a Fig. 5. Single- or multi-level multiport UPQC, derived from the MPC configuration in Ref. [70] and the multi-level configuration in Ref. [71]. The triple-dots indicate the potential scaling to multi-level. S. Harrison et al. Renewable and Sustainable Energy Reviews 203 (2024) 114742 6 multi-transformer version of a TAB [82]. Proponents of the DT TAB suggest that it offers: reduced circulating current between ports, reduced transformer inrush current, improved lifetime, and reduced losses [83]. Modular multi-active bridge (MMAB) converters are a multitransformer variant of the MAB, which can offer improved modularity due to their ability to interconnect standard modules. An example is pictured in Fig. 7. They can also offer improved scalability by varying the connection approach of each module [84]. MMABs have been shown to be at risk of high frequency oscillations, although hardware and control solutions have also been proposed to mitigate these issues [85]. Capacitor-inductor-inductor (CLL) resonant configurations are composed of two independent half-bridge CLL resonant converters, each interconnected to a single-phase bridge rectifier via their own independent transformer cores [87]. The dual-transformer CLL resonant converter offers soft switching and therefore a higher switching frequency, a wide range of input and output voltages, and a simple filter structure. The multiport CLL resonant converter is also shown to be capable of managing the power flows through a central controller without the need for communication devices between ports [87]. 3.3. Partially-isolated multiport power converters Partially isolated MPCs integrate three or more energy ports using at least two conversion stages. Typically, this involves incorporating one isolated and one non-isolated stage, but can include multiples of each. As a result, partially isolated MPCs can offer some of the benefits of both isolated and non-isolated MPCs. Partially isolated MPCs can offer high operational flexibility with highly controllable ports and can interface different voltage levels across the isolated stage. They can also use simple additive configurations to interface additional ports without significantly increasing the number of active or passive devices, which may offer more cost-effective solutions compared to fully-isolated topologies. Partially isolated MPCs are further classified according to the realisation of the isolation stage. Fig. 6. Series resonant multi-active bridge (MAB) [79]. Fig. 7. Modular multi-transformer (MT) multi-active bridge (MAB) [86]. S. Harrison et al. Renewable and Sustainable Energy Reviews 203 (2024) 114742 7 3.3.1. Non-integrated Non-integrated partially isolated MPCs are formed by a cascaded connection of isolated and non-isolated topologies. This combination of established converters means that the configuration and control should not be significantly more complex than that of the independent conversion stages. Non-integrated solutions also offer good modularity, decoupled port voltages (with the use of shunt devices on non-isolated ports), and fault isolation across the transformer. However, the efficiency of these solutions can be reduced due to the cascaded conversion stages. Non-integrated partially isolated MPCs can also require a high DC link capacitance to minimise the interactions between the ports [88, 89] and will be subject to the impedance interaction between the cascaded converters. The non-integrated partially isolated MPCs generally include a conventional two- or three-level VSC that interfaces an AC port with a DC port before achieving isolation and integrating additional ports using a DC-DC converter [90]. combines an isolated DAB DC-DC converter with a rectifier to interface two DC sources to the AC grid [91]. cascades a three-phase six-switch power factor correction (PFC) as the AC-DC stage with a phase shifted full-bridge (PSFB) as the DC-DC stage (as shown in Fig. 8). The interconnection of a three-phase three-level T-type PFC with a single winding multi-transformer type DC-DC converter that includes a full-bridge on the primary side and a buck on the secondary is proposed in Ref. [92] for battery charging applications. Additionally, a three-port converter solution that achieves galvanic isolation of the AC grid port from its two DC ports (PV and battery ESS) [93] appears to be one of the only MPC solutions available on the market that is explicitly designed for a DN application. 3.3.2. Integrated Integrated partially isolated MPCs merge the isolation stage within the main topology, eliminating the need for cascaded converters. This approach enables integrated solutions to operate with a lower number of active devices and a reduced DC link capacitance compared to nonintegrated solutions. However, the integration can result in complex configurations and controls that can be challenging to adapt modularly. In the case of interfacing only DC ports [94], proposes a MPC by integrating a bidirectional PWM converter and a series resonant converter. This integration reduces the number of semiconductors and enables the integration of magnetic components into a single magnetic element. Furthermore [95], presents a partially isolated MPC for EV batteries with automatic current balancing, interleaved PWM control, and enhanced transformer utilisation. In the case of interfacing AC and DC ports [96], considers a dual three-phase active bridge as a MPC by simultaneously accounting for the AC and DC ports on the primary side separately from the isolated AC and DC ports on the secondary side (pictured in Fig. 9) [97]. develops a three-phase single-stage isolated converter, which combines a three-phase PFC discontinuous-current-mode boost rectifier with an inductor-inductor-capacitor (LLC) resonant half-bridge converter and two additional switches. The usefulness of this MPC lies in its ability to achieve a tightly regulated isolated output voltage while enabling zero-voltage switching on the additional switches throughout the entire input and load range. There is one example of an integrated partially isolated MPC solution available on the market [98], however, its ULV configuration suggests it is not particularly relevant for DN applications. 3.4. Examples of multiport power converters for higher voltage applications A MV application that may benefit from the use of MPCs is the enhanced SOP, which is described for this study in Section 4.1 as interfacing two MV AC ports (representing DN lines) to a LV DC port (for the integration of a RES or ESS). This application is suited to MPCsolutions that provide high voltage gain and isolation (to support the interfacing of different voltage levels) as well as being scalable (to support the large voltages of the MV ports). [99] proposes a MPC for MV applications that connects two AC ports using a back-to-back multilevel converter composed of series connected Fig. 8. Cascaded two-stage PFC and PSFB [91]. Fig. 9. Dual three-phase active bridge [96]. S. Harrison et al. Renewable and Sustainable Energy Reviews 203 (2024) 114742 8 half-bridge cells (pictured in Fig. 10). The converter becomes a MPC when the common DC link that decouples the AC ports integrates an additional energy port. The series connection of the submodule cells allows the generation of any AC voltage level. This half-bridge configuration would require an additional converter stage to interface a DC ESS or distributed generator and would therefore resemble a conventional multi-stage converter, however, a full-bridge configuration could control the DC voltage and therefore interface a DC port without additional stages. [100] proposes an AC-AC-DC converter for MV applications that utilises a multi-winding medium frequency transformer (pictured in Fig. 11). The AC ports are interfaced to their windings across cascaded full-bridge cells and the DC port is interfaced using a single-phase AC-DC conversion stage. Additional resonant circuits and/or transformer solutions can be used to reduce the overload requirement of the transformer core. The AC circuit configuration is repeated for each phase. [101] proposes a multilevel modular smart transformer that also integrates two MV AC ports with a DC port. The configuration uses a series connected cascaded half-bridge configuration that allows the interconnection of the AC ports to either side of a multilevel multi-winding multi-transformer-type DC-DC converter. One winding from the secondary side of each transformer core connects in parallel to contribute to the DC port. The DC-DC converter unit can take different forms, such as those described in Section 3.2), the choice of which is likely to be informed by the individual unit’s characteristics. A three-port UPFC is developed for high voltage transmission network applications in Ref. [102], which uses a modular multilevel shunt converter and two series connected converters to interface to the ultra-high voltage grid (the multilevel configuration pictured in Fig. 5). Two-port multilevel UPQCs for DN applications are also developed, which include: diode clamped [103], neutral-point clamped [104], and flying capacitor [105] converter approaches. Other studies are shown to implement either two-level [67,75] or modular multilevel converters [64] on the series side to remove the need for the series transformer in two-port applications. 4. Method for MPC topology comparison An adapted Pugh Matrix method [106–108] is developed to compare the MPC topologies using the information collected throughout the literature review in Section 3. The comparison accounts for the variable importance of desirable features for different application scenarios. The scenarios represent specific configurations of the applications that MPCs are expected to support the electrical power system’s decarbonisation. The method consists of four stages. Firstly, each scenario is defined in terms of the critical qualifying features that are required to achieve the given function. These qualifying features are: the number of ports, the number of bidirectional ports, the number of AC, and the number of DC ports. Additionally, scenarios require the galvanic isolation of ports in Protection Zone 0 from any ports in Protection Zones 1–4, as defined for DC distribution networks in Refs. [32,45]. Protection Zones are determined according to the voltage and current characteristics of each port. Section 4.1 and Table 2 describe the four scenarios and their critical features that will be used to qualify Fig. 10. Modular half-bridge-based converter [99]. The triple-dots indicate the potential scaling to multi-level. S. Harrison et al. Renewable and Sustainable Energy Reviews 203 (2024) 114742 9 topologies. The topologies’ critical features are compared with the requirements in Table 2 to identify if they qualify for the given scenario. An additional feedback loop is included in this qualification procedure to allow topologies with an insufficient number of AC ports to use additional inverters or those that require isolation of Protection Zone 0 ports to use additional transformers to meet the requirements. This use of an inverter is stated as a common solution for DC-DC MPCs [22], as is the interfacing of a converter to the AC network via a transformer, and allows the assessment of the suitability of the full range of MPC topologies. The number of switches and passive devices recorded for each topology are increased by 12 and 3 per additional inverter, while a single transformer with 6 windings (passive components) are added for those that require isolation to meet the scenario specifications. The weighting stage then defines the importance of the non-critical but desirable MPC features for the given application. A weight from 0 to 3 is applied to each feature, where a weight of 0 signifies that the feature has no importance and a weight of 3 signifies that the feature is Fig. 11. Modular medium-frequency transformer-based converter [100]. The triple-dots indicate the potential scaling to multi-level. Table 2 Application scenario specifications, including the qualifying port features. Scenario Application Qualifying (port) features Total ports Bi-directional ports AC ports DC ports Isolated (Zone 0) ports 1 Enhanced SOP 2 ×20 kV 400 kVA DN feeders, 1 ×400 V 100 kW solar PV 3 2 2 1 0 a 2 Residential Building 1 ×400 V 30 kVA DN feeder, 1 ×120 V 3.5 kW solar PV, 1 ×50 V 17.5 kW ESS, 1 ×250 V 7.4 kW EV charger 4 2* 1 3 0 3 Facility Building 1x 600 kVA AC DN, 1 ×400 kW UPS, 1 ×85 kW solar PV, AC and DC critical loads (~500 kW), 1x Diesel generator (600 kVA); all at ~400 V 6 2 3 3 3 4 Remote Community 1 ×240 V 20 kVA DN, 1 ×120 V 12 kW solar PV, 1 ×50 V 8 kW ESS +1 ×20 kV 50 kVA future DN feeder 3 +1 2 +1 1 +1 2 0 +1 a indicates that no ports need to be isolated (according to the isolation requirement defined by Ref. [32]) as the MPC only interfaces ports in Protection Zone 0. * indicates the assumption that the EV port only charges and does not provide vehicle to grid services. +indicates a projected future port. S. Harrison et al. Renewable and Sustainable Energy Reviews 203 (2024) 114742 16 [55] muRata. MYMGC3R32EFPF2RV | datasheet | DC-DC converter [Online]. Available: https://www.murata.com/products/productdata/8807035142174/ MYMGC3R32EFPF2RV.pdf?1583754814000. [Accessed 15 December 2023]. [56] Mornsun. AC/DC converter universal type (multiple outputs) (30-150W) [Online]. Available: https://www.mornsun-power.com/html/products/2197/un iversal-type–multiple-outputs–30-150w.html. [Accessed 15 December 2023]. [57] Mohapatra S, Mohapatro S. Non-isolated bidirectional multiport converter for LVDC microgrid. In: 2021 national power electronics conference (NPEC); Dec. 2021. p. 1–6. https://doi.org/10.1109/NPEC52100.2021.9672466. [58] Kumood, Kumar K, Dalal J, Kumar M. Solar PV fed non-isolated DC-DC multiport converter. In: 2023 international conference on power, instrumentation, control and computing (PICC); Apr. 2023. p. 1–6. https://doi.org/10.1109/ PICC57976.2023.10142411. [59] Bhattacharyya P, Ghorai S, Sen S, Giri SK. A flexible non-isolated multiport converter to integrate battery and ultracapacitor for electric vehicle applications. IEEE Trans. Circuits Syst. II Express Briefs Mar. 2023;70(3):1044–8. https://doi. org/10.1109/TCSII.2022.3217844. [60] Singh PP, Chandra S, Tiwari A. Study and implementation of boost-derived hybrid converter with simultaneous DC and AC outputs. In: 2017 recent developments in control, automation & power engineering (RDCAPE); Oct. 2017. p. 388–93. https://doi.org/10.1109/RDCAPE.2017.8358302. [61] Jeyasudha S, Geethalakshmi B. Modeling and analysis of a novel boost derived multilevel hybrid converter. Energy Proc Jun. 2017;117:19–26. https://doi.org/ 10.1016/j.egypro.2017.05.102. [62] Ahmad A, Bussa VK, Singh RK, Mahanty R. Quadratic boost derived hybrid multioutput converter. IET Power Electron 2017;10(15):2042–54. https://doi.org/ 10.1049/iet-pel.2017.0171. [63] Kim H, Parkhideh B, Bongers TD, Gao H. Reconfigurable solar converter: a singlestage power conversion PV-battery system. IEEE Trans Power Electron Aug. 2013; 28(8):3788–97. https://doi.org/10.1109/TPEL.2012.2229393. [64] Khadkikar V. Enhancing electric power quality using UPQC: a comprehensive overview. IEEE Trans Power Electron May 2012;27(5):2284–97. https://doi.org/ 10.1109/TPEL.2011.2172001. [65] Georgilakis PS, Hatziargyriou ND. Unified power flow controllers in smart power systems: models, methods, and future research. IET Smart Grid 2019;2(1):2–10. https://doi.org/10.1049/iet-stg.2018.0065. [66] Padiyar KR. FACTS controllers in power transmission & distribution. Illustrated edition. Anshan Ltd; 2009. [67] Bottrell N, Terry S, Ash N, Grella L. Active response to distribution network constraints. AIM; 2019. https://doi.org/10.34890/945. [68] Lee K, Koizumi H, Kurokawa K. Voltage control of D-UPFC between a clustered PV system and distribution system. In: 2006 37th IEEE power electronics specialists conference; Jun. 2006. p. 1–5. https://doi.org/10.1109/ pesc.2006.1711964. [69] Awal MA, Bipu MRH, Chen S, Khan M, Yu W, Husain I. A grid-forming multi-port converter using unified virtual oscillator control. In: 2020 IEEE energy conversion congress and exposition (ECCE); Oct. 2020. p. 4300–7. https://doi.org/10.1109/ ECCE44975.2020.9236087. [70] Han B, Bae B, Kim H, Baek S. Combined operation of unified power-quality conditioner with distributed generation. IEEE Trans Power Deliv Jan. 2006;21(1): 330–8. https://doi.org/10.1109/TPWRD.2005.852843. [71] Han B, Bae B, Baek S, Jang G. New configuration of UPQC for medium-voltage application. IEEE Trans Power Deliv Jul. 2006;21(3):1438–44. https://doi.org/ 10.1109/TPWRD.2005.860235. [72] Rong Y, Li C, Tang H, Zheng X. Output feedback control of single-phase UPQC based on a novel model. IEEE Trans Power Deliv Jul. 2009;24(3):1586–97. https://doi.org/10.1109/TPWRD.2009.2016802. [73] Kwan KH, Chu YC, So PL. Model-based \hboxH_ınfty control of a unified power quality conditioner. IEEE Trans Ind Electron Jul. 2009;56(7):2493–504. https:// doi.org/10.1109/TIE.2009.2020705. [74] Khadkikar V, Chandra A. UPQC-S: a novel concept of simultaneous voltage sag/ swell and load reactive power compensations utilizing series inverter of UPQC. IEEE Trans Power Electron Sep. 2011;26(9):2414–25. https://doi.org/10.1109/ TPEL.2011.2106222. [75] Abdelrahman MA, Yang P, Ming W, Wu J, Jenkins N. Modified unified power flow controller for medium voltage distribution networks. IET Gener Transm Distrib 2022;16(19):3849–59. https://doi.org/10.1049/gtd2.12567. [76] Duarte JL, Hendrix M, Simoes MG. Three-port bidirectional converter for hybrid fuel cell systems. IEEE Trans Power Electron Mar. 2007;22(2):480–7. https://doi. org/10.1109/TPEL.2006.889928. [77] Biswas I, Kastha D, Bajpai P. Small signal modeling and decoupled controller design for a triple active bridge multiport DC–DC converter. IEEE Trans Power Electron Feb. 2021;36(2):1856–69. https://doi.org/10.1109/ TPEL.2020.3006782. [78] Hu Y, Xiao W, Cao W, Ji B, Morrow DJ. Three-port DC–DC converter for standalone photovoltaic systems. IEEE Trans Power Electron Jun. 2015;30(6):3068–76. https://doi.org/10.1109/TPEL.2014.2331343. [79] Krishnaswami H, Mohan N. Three-port series-resonant DC–DC converter to interface renewable energy sources with bidirectional load and energy storage ports. IEEE Trans Power Electron Oct. 2009;24(10):2289–97. https://doi.org/ 10.1109/TPEL.2009.2022756. [80] Micross. Hybrid DC-DC converters [Online]. Available: https://www.micross.com /products-and-services/hi-rel-power-solutions/hybrid-dc-dc-converters. [Accessed 15 December 2023]. [81] Heo K-W, Yun C-W, Jung G-G, Lee J-S, Kim H-S, Jung J-H. Enhanced four-port dual-active-bridge converter employing power decoupling capability for DC microgrid islanding mode operation. J. Power Electron. Dec. 2023. https://doi. org/10.1007/s43236-023-00712-1. [82] Oluwasogo ES, Cha H. Self-current sharing in dual-transformer-based triple-port active bridge DC–DC converter with reduced device count. IEEE Trans Power Electron May 2021;36(5):5290–301. https://doi.org/10.1109/ TPEL.2020.3029829. [83] Jakka VNSR, Shukla A, Demetriades GD. Dual-transformer-based asymmetrical triple-port active bridge (DT-ATAB) isolated DC–DC converter. IEEE Trans Ind Electron Jun. 2017;64(6):4549–60. https://doi.org/10.1109/TIE.2017.2674586. [84] Ortega L, Zumel P, Fern´ andez C, L´ opez-L´ opez J, L´ azaro A, Barrado A. Power distribution algorithm and steady-state operation analysis of a modular multiactive bridge converter. IEEE Trans. Transp. Electrification Sep. 2020;6(3): 1035–50. https://doi.org/10.1109/TTE.2020.3010003. [85] Wei S, Zhao Z, Yuan L, Wen W, Chen K. Voltage oscillation suppression for the high-frequency bus in modular-multiactive-bridge converter. IEEE Trans Power Electron Sep. 2021;36(9):9737–42. https://doi.org/10.1109/ TPEL.2021.3063500. [86] Zumel P, Fernandez C, Lazaro A, Sanz M, Barrado A. Overall analysis of a modular multi active bridge converter. In: 2014 IEEE 15th workshop on control and modeling for power electronics (COMPEL); Jun. 2014. p. 1–9. https://doi.org/ 10.1109/COMPEL.2014.6877198. [87] Asa E, Colak K, Bojarski M, Czarkowski D. Asymmetrical duty-cycle and phaseshift control of a novel multiport CLL resonant converter. IEEE J. Emerg. Sel. Top. Power Electron. Dec. 2015;3(4):1122–31. https://doi.org/10.1109/ JESTPE.2015.2408565. [88] Zhang D, Wang F, Burgos R, Lai R, Boroyevich D. DC-link ripple current reduction for paralleled three-phase voltage-source converters with interleaving. IEEE Trans Power Electron Jun. 2011;26(6):1741–53. https://doi.org/10.1109/ TPEL.2010.2082002. [89] Lamar DG, Sebastian J, Arias M, Fernandez A. On the limit of the output capacitor reduction in power-factor correctors by distorting the line input current. IEEE Trans Power Electron Mar. 2012;27(3):1168–76. https://doi.org/10.1109/ TPEL.2010.2075943. [90] Feng F, Wu F, Gooi HB. Impedance shaping of isolated two-stage AC-DC-DC converter for stability improvement. IEEE Access 2019;7:18601–10. https://doi. org/10.1109/ACCESS.2019.2892080. [91] Mallik A, Khaligh A. Intermediate DC-link capacitor reduction in a two-stage cascaded AC/DC converter for more electric aircrafts. IEEE Trans Veh Technol Feb. 2018;67(2):935–47. https://doi.org/10.1109/TVT.2017.2748582. [92] Yamada R, Nemoto Y, Fujita S, Wang Q. A battery charger with 3-phase 3-level T- type PFC. In: 2015 IEEE international telecommunications energy conference (IN℡EC); Oct. 2015. p. 1–5. https://doi.org/10.1109/INTLEC.2015.7572419. [93] CET America, “CET-Datasheet-Stabiliti-30C3-EN-v1.vol. 1.”Accessed: December. 15, 2023. [Online]. Available: https://cdn.cet-power.com/uploads/2019/11/C ET-Datasheet-Stabiliti-30C3-EN-v1.1.pdf. [94] Uno M, Oyama R, Sugiyama K. Partially isolated single-magnetic multiport converter based on integration of series-resonant converter and bidirectional PWM converter. IEEE Trans Power Electron Nov. 2018;33(11):9575–87. https:// doi.org/10.1109/TPEL.2018.2794332. [95] Uno M, Sato M, Tada Y, Iyasu S, Kobayashi N, Hayashi Y. Partially isolated multiport converter with automatic current balancing interleaved PWM converter and improved transformer utilization for EV batteries. IEEE Trans. Transp. Electrification Mar. 2023;9(1):1273–88. https://doi.org/10.1109/ TTE.2022.3175032. [96] Heller MJ, Krismer F, Kolar JW. Quad-port AC–DC–DC–AC operation of isolated dual three-phase active bridge converter. In: 2021 IEEE applied power electronics conference and exposition (APEC); Jun. 2021. p. 1643–50. https://doi.org/ 10.1109/APEC42165.2021.9487240. [97] Jang Y, Jovanovi´ c MM, Kumar M, Chang Y, Lin Y-W, Liu C-L. A two-switch, isolated, three-phase AC–DC converter. IEEE Trans Power Electron Nov. 2019;34 (11):10874–86. https://doi.org/10.1109/TPEL.2019.2898120. [98] Power Integrations. DI-69 - 15 W multi-output DC-DC converter [Online]. Available: https://www.powerint.cn/design-support/design-examples/di-69-15- w-multi-output-dc-dc-converter?language=en. [Accessed 15 December 2023]. [99] Pereda J, Green TC. Direct modular multilevel converter with six branches for flexible distribution networks. IEEE Trans Power Deliv Aug. 2016;31(4):1728–37. https://doi.org/10.1109/TPWRD.2016.2521262. [100] Ma D, Chen W, Shu L, Hou K, Liu R, Zhang C. Multiport AC-AC-DC converter for SNOP with one medium-frequency transformer. CPSS Trans. Power Electron. Appl. Dec. 2022;7(4):374–85. https://doi.org/10.24295/CPSSTPEA.2022.00034. [101] Costa LF, Hoffmann F, Buticchi G, Liserre M. Comparative analysis of multiple active bridge converters configurations in modular smart transformer. IEEE Trans Ind Electron Jan. 2019;66(1):191–202. https://doi.org/10.1109/ TIE.2018.2818658. [102] Li P, Wang Y, Feng C, Lin J. Application of MMC-UPFC in the 500 kV power grid of Suzhou. J Eng 2017;2017(13):2514–8. https://doi.org/10.1049/ joe.2017.0780. [103] Chen Y, Mwinyiwiwa B, Wolanski Z, Ooi B-T. Unified power flow controller (UPFC) based on chopper stabilized diode-clamped multilevel converters. IEEE Trans Power Electron Mar. 2000;15(2):258–67. https://doi.org/10.1109/ 63.838098. [104] Soto-Sanchez DE, Green TC. Voltage balance and control in a multi-level unified power flow controller. IEEE Trans Power Deliv Oct. 2001;16(4):732–8. https:// doi.org/10.1109/61.956763. S. Harrison et al. Renewable and Sustainable Energy Reviews 203 (2024) 114742 17 [105] Xu L, Agelidis VG. Flying capacitor multilevel PWM converter based UPFC. IEE Proc. - Electr. Power Appl. Jul. 2002;149(4):304–10. https://doi.org/10.1049/ipepa:20020374. [106] Pugh S. Total design: integrated methods for successful product engineering. Addison-Wesley Publishing Company; 1991. [107] Cervone HF. Applied digital library project management: using Pugh matrix analysis in complex decision-making situations. OCLC Syst. Serv. Int. Digit. Libr. Perspect. Jan. 2009;25(4):228–32. https://doi.org/10.1108/ 10650750911001815. [108] Dincan C, Kjaer P, Chen Y, Nielsen S-M, Bak CL. Selection of DC/DC converter for offshore wind farms with MVDC power collection. In: 2017 19th European conference on power electronics and applications. EPE’17 ECCE Europe); Sep. 2017. P.1–10. https://doi.org/10.23919/EPE17ECCEEurope.2017.8099408. [109] Home Battery. Puredrive Energy 2023;1:1–-4 [Online]. Available: https://www. puredrive-energy.co.uk/home-battery. Accessed: October. 10. [110] EV Charger. Puredrive Energy 2023;1:1–3 [Online]. Available: https://www. puredrive-energy.co.uk/ev-charger/. Accessed: October. 1. [111] Ease – energy access & social enterprise [Online]. Available: https://ease.eee.stra th.ac.uk/. [Accessed 30 June 2023]. [112] De Breucker S, Engelen K, D’hulst R, Driesen J. Impact of current ripple on Li-ion battery ageing. World Electr. Veh. J. Sep. 2013;6(3). https://doi.org/10.3390/ wevj6030532. 3. [113] Manias SN. 7 - DC–DC converters. In: Manias SN, editor. Power electronics and motor drive systems. Academic Press; 2017. p. 501–611. https://doi.org/ 10.1016/B978-0-12-811798-9.00007-X. [114] Milovanovic S, Dujic D. On power scalability of modular multilevel converters: increasing current ratings through branch paralleling. IEEE Power Electron. Mag. Jun. 2020;7(2):53–63. https://doi.org/10.1109/MPEL.2020.2984350. [115] R. Marshall, J. Wu, and C. Plet, “D12.a meshed HVDC transmission network technology readiness level review. [116] Tarzamni H, Gohari HS, Sabahi M, Kyyr¨ a J. Nonisolated high step-up DC–DC converters: comparative review and metrics applicability. IEEE Trans Power Electron Jan. 2024;39(1):582–625. https://doi.org/10.1109/ TPEL.2023.3264172. [117] Jiang X, Zhou Y, Ming W, Yang P, Wu J. An overview of soft open points in electricity distribution networks. IEEE Trans Smart Grid May 2022;13(3): 1899–910. https://doi.org/10.1109/TSG.2022.3148599. [118] Electricity NIC submission: UK power networks– active response to distribution network constraints,” Ofgem. Accessed: January. 5, 2024. [Online]. Available: https://www.ofgem.gov.uk/publications/electricity-nic-submission-uk-power- networks-active-response-distribution-network-constraints. S. Harrison et al.