scieee AI-readable full text Open interactive document viewer

Voltammetric study of triazole antifungal agent terconazole on sp3 and sp2 carbon-based electrode materials

Fischer, Jan,González Martín, Javier,Lochyński, Paweł,Dejmková, Hana,Schwarzová Pecková, Karolina,Vega, Marisol

Abstract

Producción Científica

Full text

Journal Pre-proof Voltammetric study of triazole antifungal agent terconazole on sp3 and sp2 carbon-based electrode materials Jan Fischer, Javier González-Martín, Pawel Lochyński, Hana Dejmková, Karolina Schwarzová-Pecková, Marisol Vega PII: S1572-6657(20)30237-X DOI: https://doi.org/10.1016/j.jelechem.2020.114054 Reference: JEAC 114054 To appear in: Journal of Electroanalytical Chemistry Received date: 9 December 2019 Revised date: 7 March 2020 Accepted date: 9 March 2020 Please cite this article as: J. Fischer, J. González-Martín, P. Lochyński, et al., Voltammetric study of triazole antifungal agent terconazole on sp3 and sp2 carbon-based electrode materials, Journal of Electroanalytical Chemistry(2020), https://doi.org/10.1016/ j.jelechem.2020.114054 This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain. © 2020 Published by Elsevier. Journal Pre-proof 1 Voltammetric study of triazole antifungal agent terconazole on sp3 and sp2 carbon-based electrode materials Jan Fischer a, Javier González-Martín a,b, Pawel Lochyński c, Hana Dejmková a, Karolina Schwarzová-Pecková a, Marisol Vega b,d* a Charles University, Faculty of Science, Department of Analytical Chemistry, UNESCO Laboratory of Environmental Electrochemistry, Albertov 6, CZ-12843, Prague 2, Czech Republic b University of Valladolid, Institute of Sustainable Processes, Dr. Mergelina s/n, 47011 Valladolid, Spain c Wroclaw University of Environmental and Life Sciences, Institute of Environmental Engineering, Norwida 25, PL-50375 Wroclaw, Poland d University of Valladolid, Department of Analytical Chemistry, Faculty of Science, Campus Miguel Delibes, Paseo de Belén 7, 47011 Valladolid, Spain, [email protected] Abstract Terconazole belongs to synthetic triazole antifungal agents, inhibiting biosynthesis of ergosterol or other sterols and thus disrupting cell wall synthesis in fungi. In this study, electrochemical behaviour of terconazole was studied for the first time using cyclic voltammetry and differential pulse voltammetry on boron doped diamond electrode (BDD) with different surface treatments leading to O-terminated, H-terminated and polished surfaces, as well as on glassy carbon (GCE) and basal-plane pyrolytic graphite electrodes (PGE). Terconazole is not reducible within the potential window on these electrode materials. It is oxidizable in aqueous solutions in pH range from 2.0 to 12.0 in two steps due to the presence of piperazine ring in its molecule, possessing two redox centres at the tertiary nitrogen atoms, by an ECE mechanism. Optimal conditions were found for determination of terconazole in 0.1 mol L–1 phosphate buffer pH 7.2. Using differential pulse voltammetry, the lowest detection limit of 0.40 mol L−1 and excellent repeatability (RSD 1.1 %) were achieved on O- terminated BDD when in-situ anodic activation was used prior to each scan. This is beneficial in comparison with GCE and PGE; their necessity of ex-situ polishing worsens the signal repeatability (RSD ~ 4%) and detection limits reaching 0.50 mol L−1 and 1.23 mol L−1, respectively. Journal Pre-proof Journal Pre-proof 2 Keywords Boron doped diamond electrode; Glassy carbon electrode; Pyrolytic graphite electrode; Surface termination; Terconazole; Voltammetry. 1. Introduction Azoles are a group of chemicals used as pesticides or pharmaceuticals, acting as antifungal agents. The diazole (imidazole) or triazole rings are key building blocks of these compounds, modulating their biological activity, possibly together with other moieties included in their molecules such as piperazine heterocycle [1]. Azoles show selective inhibition of cytochrome P450 enzymes leading to disruption of the pathways of synthesis of ergosterol, an essential fungal sterol present in cell membranes [2]. Terconazole ((+-)-1-{4-[cis-2-(2,4- Dichlorophenyl)-2-(1H-1,2,4-triazol-1-ylmethyl)-1,3-dioxolan-4-ylmethoxy]phenyl}-4- isopropylpiperazine), possessing triazole and piperazine rings in its structure (Scheme 1), is used as antimycotic agent. It inhibits the activity of the cytochrome P450 14-alpha- demethylase in Candida species [3], which leads to the accumulation of lanosterol and other methylated sterols and the decrease in ergosterol concentration. Thus, it is used in suppositories and creams to treat vulvovaginal candidiasis. Both administration forms have demonstrated high levels of safety, efficacy, and tolerability in clinical trials [4]. It is a chiral drug, in praxis used as a racemic mixture. Nevertheless, pharmacological activity of individual enantiomers can be different, which leads to efforts on differentiation between them (only two enantiomers of terconazole exist because of the cis configuration of the 2,4- dichlorophenyl group and hydrogen at the two chiral centers) [5]. Several reports exist on determination of terconazole alone or in combination with other drugs and preservatives used in pharmaceutical preparations. A spectrophotometric method has been developed for determination of terconazole in dosage forms [6]. Simultaneous determination with the preservative benzoic acid was achieved using derivative spectrophotometry and high performance liquid chromatography with UV detection [7]. The latter methods and micellar liquid chromatography were used for determination of terconazole in dosage forms and human plasma [8]. Electrokinetic chromatography enables separation of the two enantiomers of terconazole [5]. Stability testing of terconazole, identification of impurities and characterization of products raised by forced degradation have been performed based on ultra-performance liquid chromatography coupled to time of flight tandem mass spectrometry (UPLC-Q-TOF/MS/MS) and NMR [9]. Journal Pre-proof Journal Pre-proof 3 Concerning the electrochemistry of triazole and imidazole agents, literature data are rather scarce. Since the triazole moiety is not electrochemically active, a universal approach could be the utilization of complexation reactions with metal ions [10], i.e., enhancement of voltammetric signals assigned to oxidation of a metallic electrode in the presence of the triazolic compound due to its complexation reaction [11, 12]. The direct redox activity of triazoles relies on other moieties, e.g., electrochemical oxidation of the amino group in amitrole [13, 14] or reduction of azomethine moiety (e.g., in propiconazole). The oxidizable piperazine moiety [15] enables voltammetric determination of azolic pharmaceuticals (e.g., ketoconazole, posaconazole, itraconazole) [16-22]. It follows from Table 1, which summarizes the characteristics and limits of detection of the voltammetric methods that their oxidation occurs at potentials ranging from ca +0.5 V to +0.75 V on carbon-based electrodes, including boron doped diamond (BDD). This material offers advantageous properties for electroanalysis of organic compounds, including mechanical stability, low background current, wide potential window especially in the region of positive potentials and usually low adsorbability of reaction by-products and products resulting in fouling resistivity [23-25]. Its electrochemical properties are influenced by the surface pretreatment. While in-situ anodic electrochemical activation in the region of positive potentials leads to water oxidation and generation of HO• radicals, and consequently to oxygen termination of the BDD surface (O- BDD) characterized by the presence of hydroxyl, carbonyl, ether, and carboxyl groups [26, 27], application of negative potential in the region of hydrogen evolution leads to hydrogen termination (H-BDD) [28]. The other activation approach is polishing of BDD surface by alumina (p-BDD), leading to loss of oxygen-containing groups, especially those bonded to sp2 hybridized carbons at the surface [26]. Besides the triazole pharmaceuticals ketoconazole [22], BDD succeeded in oxidation of other compounds possessing piperazine moiety, e.g., the anticancer drug imatinib [29] and fluoroquinolone antibiotic pefloxacin [30]. In this contribution, the electrochemical behaviour of terconazole has been investigated for the first time. A representative variety of sp3 and sp2 carbon-based electrodes was used for that purpose. Besides O-BDD, H-BDD, and p-BDD electrodes, glassy carbon electrode (GCE) and pyrolytic graphite electrode (PGE) were used to represent widely used sp2 carbon electrode materials. Pyrolytic graphite is a heterogenous three-dimensional graphite material, composed of parallelly stacked sheets of graphene comprising flat basal planes and edge plane perpendicular to them. It has relatively wide potential window, surprisingly also in the region of negative potentials [31]. Glassy carbon comprises of randomly intertwined ribbons of graphitic planes, thus it is disordered, with higher interplanar Journal Pre-proof Journal Pre-proof 4 spacing in comparison to pyrolytic graphite [32]. Comparison of performance of these materials in electrooxidation of terconazole was made and its mechanism proposed. A differential pulse voltammetric (DPV) quantitation method based on oxidation signal of terconazole was optimized. Journal Pre-proof Journal Pre-proof 5 Table 1. Characteristics of polarographic and voltammetric methods for detection of azolic pharmaceuticals possessing piperazine moiety. Compound Ep [V] Working electrode Reference electrode Technique Supporting electrolyte LOD [mol L-1] Ref. Itraconazole −1.48 DME Ag/AgCl DPP BRB, pH 7 0.1 [33] Ketoconazole −1.56 DME Ag/AgCl DPP BRB, pH 7 0.50 [33] Ketoconazole −1.46 p-AgSAE Ag/AgCl SWV BRB, pH 12 0.12 [34] Ketoconazole +0.54 GCE Ag/AgCl CV, AdS-DPV NH3-NH4Cl, pH 9 0.00004 [18] Ketoconazole ≈ +0.5 GCE Pd CV PB, pH 3, 5, 7 -- [16] Itraconazole ≈ +0.5 GCE Pd CV PB, pH 3, 5, 7 -- [16] Posaconazole ≈ +0.5 GCE Pd CV PB, pH 3, 5, 7 -- [16] Ketoconazole ≈ +0.6 GCE SCE CV, SWV NH3-NH4Cl, pH 9 0.075 [19] Ketoconazole ≈ +0.6 MWCNTs-GCE SCE CV, LSV, DPV PB, pH 7 0.44 [20] Ketoconazole ≈ +0.55 CPE Ag/AgCl AdS-DPV PB, pH 12 0.024 [17] Itraconazole +0.66 CPE Ag/AgCl CV, AdS-DPV, AdS-SWV BRB, pH 2 0.012 [21] Itraconazole +0.75 UTGE Ag/AgCl CV, AdS-DPV, AdS-SWV BRB, pH 2 0.015 [21] Itraconazole +0.63 PCE Ag/AgCl CV, AdS-DPV, AdS-SWV BRB, pH 2 0.013 [21] Ketoconazole +0.59 BDDE SCE SWV NH3-NH4Cl, pH 9 0.083 [22] Terconazole ≈ +0.50 O-BDDE; GCE, PGE Ag/AgCl CV, DPV PB, pH 7.2 0.4; 0.5; 1.24 This study CPE – carbon paste electrode; MWCNTs – multi-walled carbon nanotubes; PCE – pencil graphite electrode; p-AgSAE – polished silver solid amalgam electrode; UTGE – ultra-trace graphite electrode AdS – adsorptive anodic stripping; DPV – differential pulse voltammetry; SWV – square wave voltammetry; BRB – Britton ‒ Robinson buffer; PB – phosphate buffer Journal Pre-proof Journal Pre-proof 6 2. Experimental 2.1. Reagents and Solutions Terconazole was purchased from Sigma-Aldrich (VETRANAL ™, analytical standard). The standard solution (c = 1·10–3 mol L–1) was prepared in deionized water. It was stored at room temperature in the dark. Piperazine (Sigma-Aldrich, analytical standard) stock solution (c = 1·10–3 mol L–1) was prepared in deionized water. Other chemicals utilized throughout the experiments were from Czech local producers and of analytical grade (if not specified otherwise). Britton ‒ Robinson buffer was prepared by mixing 0.04 mol L–1 H3PO4, H3BO3 and CH3COOH solution with an adequate amount of 0.2 mol L–1 NaOH, to reach the required pH in the range from 2.0 to 12.0. 0.1 mol L–1 phosphate buffer pH 2.3 was prepared by mixing H3PO4 and NaH2PO4·2H2O solutions. 0.1 mol L–1 phosphate buffer pH 7.2 was prepared mixing NaH2PO4·2H2O and Na2HPO4·12H2O solutions. Borate buffer at pH 9.2 was prepared by precise addition of 0.2 mol L–1 NaOH to 0.1 mol L–1 H3BO3 solution. Deionized water was obtained from a Millipore Q-plus System (Millipore, USA). 2.2. Instrumentation Computer-controlled Eco-Tribo Polarograph system with PolarPro version 5.1 software (EcoTrend Plus, Prague, Czech Republic) was used for voltammetric measurements. All measurements were performed in the three-electrode setup with Ag|AgCl (3 mol L–1 KCl) as a reference electrode and platinum wire as an auxiliary electrode (both from Elektrochemické detektory, Turnov, Czech Republic). The working electrodes were: BDD electrode (A = 12.6 mm2, B/C= 10000 ppm when not specified otherwise, film thickness 3 µm; NeoCoat, Switzerland); basal oriented homemade PGE with square face surface area of A = 9 mm2; glassy carbon disk electrode (A = 3.1 mm2; Metrohm, Switzerland). The pH measurements were carried out by digital pH Meter 3510 (Jenway, UK) with combined glass electrode. 2.3. Procedures The measured volume of supporting electrolyte and sample was 10 mL, unless otherwise specified. The surfaces of the electrodes were pretreated and activated between individual scans as follows: p-BDD – pretreated by polishing using Al2O3 (0.5 m) suspension (Elektrochemické detektory, Turnov, Czech Republic) in deionized water for 5 min, followed by sonication in methanol and deionized water to remove the alumina residues. Activation prior each scan was performed by polishing using Al2O3 suspension for 30 s; O-BDD – a Journal Pre-proof Journal Pre-proof 7 pretreatment potential of +2.4 V was applied for 20 min in stirred 0.5 mol L–1 H2SO4 solution and 5 minutes in supporting electrolyte before each series of measurements. Anodic activation at +2.4 V for 5 s directly in measured solution was also applied between individual scans in optimized DPV procedure and in measurement of the scan rate dependence by cyclic voltammetry; H-BDD – a pretreatment potential of −2.4 V was applied for one hour in stirred 0.5 mol L–1 H2SO4 solution before all measurements, and 5 min before each series of measurement. Measurement in positive potential region was carefully performed within the potential window of H-BDD to prevent surface oxygenation and conversion to O-BDD. GCE was polished using Al2O3 suspension in deionized water for 30 s followed by rinsing with deionized water prior to each scan. The surface of PGE was dried after each scan and renewed using adhesive tape. Unless otherwise stated, a scan rate of 20 mV s–1, pulses with a duration of 80 ms and modulation amplitude ±50 mV were used in DPV. For CV, scan rate of 100 mV s–1 was set. Peak-current values (Ip) were evaluated from the line connecting current minima at both sides of the voltammetric peak. All the solutions were degassed by 5 min passing nitrogen, before measurements were performed. The concentration dependences were constructed from the average of four replicate measurements for each concentration of terconazole and were evaluated by the least squares linear regression method. For differential pulse voltammetry, the limits of detection (LD) were calculated as a threefold of the standard deviation s of the peak currents (ten runs) of the lowest measurable concentration, divided by the slope of corresponding calibration curve. 3. Results and discussion 3.1. Voltammetric studies of terconazole and characterization of its redox reactions Firstly, cyclic voltammetry of 1 mmol L–1 [Fe(CN)6]3−/4− redox couple recorded in 1 mol L–1 KCl at the scan rate of 0.1 mV s–1 was used for characterization of tested electrode surfaces. The peak potential difference Ep between anodic and cathodic peaks of [Fe(CN)6]3−/4− recorded on different BDD surfaces (O-BDD, H-BDD, and p-BDD), and further on PGE and GCE, were 410 ± 20 mV, 85 ± 10 mV, 90 ± 5 mV, 550 ± 25 mV, and 65 ± 4 mV, respectively. These values clearly indicate differences in chemical composition of moieties terminating tested surfaces, as it is known that oxygen containing groups with - electrons inhibit electron transfer of this redox marker [32]. Journal Pre-proof Journal Pre-proof 8 Then, cyclic voltammetry was used as the first-choice technique to characterize the electrochemical behavior of terconazole on different BDD surfaces (O-BDD, H-BDD, and p- BDD), PGE and GCE in acidic (phosphate buffer pH 2.3), neutral (phosphate buffer pH 7.2), and alkaline (borate buffer pH 9.3) media. CVs recorded in anodic direction are depicted in Fig. 1. The main oxidation signal at potentials ranging from ca +0.55 V to +0.90 V (depending on the electrode material) is observable on all electrodes and in all electrolytes tested and it shifts slightly to less positive values with increasing pH. This indicates that the redox-active group is in acid-base equilibrium and the proton transfer precedes the electron transfer rate-determining step. This oxidation step is irreversible in all instances with the exception of acidic media on PGE and H-BDD, where a quasireversible process was observed with Ep of 0.1 V and 0.09 V, respectively. Such behavior was previously observed also for ketoconazole [22]. It can be ascribed to the electron uptake from piperazine moiety leading to the formation of radical cation at the proximal nitrogen (aminium radical cation), and fast reverse cathodic reaction. For both ketoconazole and terconazole, this quasireversible behavior was observed only in acidic media and on relatively hydrophobic surfaces (for details see further Scheme 1 and attached description of oxidation mechanism of terconazole). When comparing peak potentials Ep for the mentioned electrode materials, no substantial differences can be traced, confirming similar interaction of terconazole and its oxidation byproducts with the mentioned surfaces and similar kinetics of electron transfer. It is important in the view of other studies, where substantial differences in positioning of anodic/cathodic signals were reported when comparing BDD with other carbon-based electrodes [23, 35, 36] or when comparing O-, H- and polished BDD surfaces, with the O- terminated one, observed to inhibit electron transfer and thus shifting anodic/cathodic signals to more positive/negative potentials [37]. The second peak appearing at more positive potentials at ca +1.0 V – + 1.25 V is well observable on O-BDD and p-BDD in all media and on H-BDD in acidic media. On the other hand, it is absent on CVs recorded on the sp2 carbon electrode materials due to its low intensity or narrower potential windows of the latter electrodes. Nevertheless, it can be visualized on all electrode materials using differential pulse voltammetry. DP voltammograms of 1·10–4 mol L–1 terconazole on O-BDD, GCE and PGE at different pH values are presented in Fig. 2 and the corresponding peak potential Ep vs. pH dependences are depicted in Fig. 3. For the first anodic signal, the linearity of these dependences is described by the following equations (1-3) for O-BDD, GCE, and PGE, respectively, in pH range 4.0 –12.0: Ep,O-BDD (mV) = −25.1 pH + 776 (R2 = 0.991) (1) Journal Pre-proof Journal Pre-proof 15 Further, cyclic voltammograms are characterized by the presence of reduction signals in the reverse cathodic scan at the potential of ca 0 V to −0.6 V. Fig. 4 shows that these cathodic processes are associated with preceding oxidation processes, as the respective signal appears at the CVs only when the positive vertex potential is set just after the first oxidation peak (Fig. 4, curve B) and remains rather unchanged when the scan is reversed after the second oxidation peak. Thus, the cathodic process is presumably associated with reduction of compound 5. The mechanism is questionable, nevertheless one-electron reductive cleavage of the bond between the proximal nitrogen and the benzene ring leading to piperazine and benzyl radical-type triazole derivative is probable, similarly as described for sodium 4-(3- methoxyphenyl)piperazine-1-carbodithioate (SMPC) containing structurally related moiety [42]. Terconazole itself is not reducible within the potential window of the studied carbonbased electrodes, as presented in 0.1 mol L–1 phosphate buffer pH 7.2 for O-BDD: no cathodic peak appears unless terconazole is oxidized first (Figure 4, curve C). This confirms different electrochemical behavior of the piperazine moiety, conjugated or standing alone, as the latter form is reducible at −0.67 V as presented in Fig. S1, while the former is inactive in a variety of compounds including azole agents summarized in Table 1. For some of them, appearance of cathodic signals was reported, but different moieties were supposed to be reduced, e.g. the carbonyl group of triazolone moiety in itraconazole [52] or carbonyl group of the terminal acid amide group of ketoconazole [33, 34]. Journal Pre-proof Journal Pre-proof 16 O O N N N ON N CH3 CH3Cl Cl O O N N N ON+N CH3 CH3Cl Cl O O N N N ON N+ CH3 CH3Cl Cl -e- distal proximal -H+ -e- O O N N N ON+N CH3 CH3Cl Cl H O O N N N ONH2+NCl Cl CH3 CH3 O +H2O + -H+ pKa 8.8 O O N N N OCNH2+N+Cl Cl -e- +e- 1 2 3 5 4 6 Journal Pre-proof Journal Pre-proof 17 Scheme 1 Proposed mechanism of electrochemical oxidation of terconazole on carbon electrodes. Journal Pre-proof Journal Pre-proof 18 -1 0 1 5 A m-2 C SE A i E, V B Fig. 4 Cyclic voltammograms of 1·10–4 mol L–1 terconazole on O-BDDE in 0.1 mol L–1 phosphate buffer pH 7.2. Measured in potential range: (A) −1.50 V to +1.80 V (dotted line represents supporting electrolyte) (B) from −1.50 V to +0.95 V, (C) and from +0.45 V to −1.50 V. Scan rate 100 mV s–1. 3.2. Optimization of voltammetric techniques and concentration dependences Differential pulse voltammetry was used for quantitation of terconazole on O-BDD, PGE and GCE, using optimized electrode conditioning protocols, in 0.1 mol L–1 phosphate buffer pH 7.2. While renewal of GCE and PGE surface must be performed ex-situ using polishing by alumina and surface renewal using adhesion tape, respectively, O-BDD has the advantage of in-situ activation directly in the analyzed solution. Remarkable fouling of O-BDD surface characterized by peak height decrease by about 70 % was observed during five consecutive scans with the highest drop between the first and second scan (57 %), when no activation procedure was applied prior each scan. The successful strategy of surface conditioning entails the application of +2.4 V for 5 seconds while stirring, followed by 5 s of stabilization of the solution prior to scan. Absence of stabilization break leads to decreased repeatability of peak heights. Relative standard deviation (RSD) of peak heights (c = 1·10–4 mol L–1) calculated for repeated DP voltammograms using this procedure is 1.1 %. The same protocol omitting the insertion of the positive potential resulted in RSD of 1.8 %. Nevertheless, the first recorded Journal Pre-proof Journal Pre-proof 19 curve was higher in comparison with the others, which would lead to complications when evaluating the analytical performance of the O-BDD electrode. This low RSD values widely outperform values obtained at GCE (4.6 %) and PGE (4.0 %); nevertheless, even these are acceptable if accepting the necessity of ex-situ regeneration of the surface of these electrodes. Concentration dependences were measured using optimized protocols in 0.1 mol L–1 phosphate buffer pH 7.2. While for O-BDD they were evaluated for both anodic peaks, for GCE and PGE only the first one was taken into consideration as the second signal on these electrodes was rather indistinctive. Parameters of obtained calibration dependences are summarized in Table 2. On O-BDD, two linear ranges were obtained for both peaks, one for concentration range from 0.2 to 4 mol L–1, and the other for higher concentrations, from 4 to 100 mol L–1. The corresponding voltammograms and concentration dependences depicted in Fig. 5 clearly demonstrate the possibility of detection of terconazole in submicromolar range on O-BDD with detection limit of 0.40 mol L−1. The other tested electrode materials exhibited comparable (GCE, 0.50 mol L−1) or higher (PGE, 1.23 mol L−1) detection limits. Both sp2 carbon electrodes required ex-situ polishing of the surface. An advantage of GCE was linearity of concentration dependence within the whole range from 1 to 100 mol L–1. The mentioned LD values cannot be directly compared with other electroanalytical techniques, as no other reports were found in the literature. Voltammetric methods for structurally related piperazine-based azolic agents, summarized in Table 1, exhibit comparable or higher LD values for approaches based on reduction on mercury-based electrodes [33,34]. Methods based on the oxidation process usually resulted in lower LDs in 10‒8 mol L−1 concentration range; nevertheless, it should be mentioned that they take advantage from the very strong adsorption of the azolic agents on the sp2 carbon electrode surfaces, which is not the case of terconazole with redox process controlled by diffusion instead. BDD electrode (presumably in O-terminated mode according to given data) was used only for determination of ketoconazole with diffusion-controlled redox reaction and experimental detection limit of 0.30 mol L−1 [22] was reached. Thus, similar analytical performance was found in our study for terconazole, holding the advantage of in-situ activation procedure. Comparison of the presented electroanalytical with other analytical techniques favors the former approach. UV detection coupled to HPLC [7] or micellar liquid chromatography [8] resulted in LDs in 10‒6 mol L−1 concentration range, similarly as first order derivative Journal Pre-proof Journal Pre-proof 20 spectrophotometry [7]. Comparable LD in 10‒7 mol L−1 concentration range was obtained for UHPLC with photodiode array detector [9]. Journal Pre-proof Journal Pre-proof 21 Table 2 Parameters of concentration dependences and limits of detection, LD, of terconazole obtained by DP voltammetry in 0.1 mol L–1 phosphate buffer pH 7.2 on O-BDDE, GCE and PGE. 0.0 0.5 1.0 0.1 0.2 (A) SE 0.2 I, µA E, V 1.0 µmol L-1 0.0 0.5 1.0 0.0 0.5 1.0 (B) SE I, µA E, V 10 µmol L-1 1 050 100 0 2 4 6(C) Ip, µA c, µmol L-1 Fig. 5 DP voltammograms for (A) the lowest measurable concentration range 0.2, 0.4, 0.6, 0.8, and 1 mol L–1 and (B) 1, 2, 4, 6, 8, and 10 mol L–1; (C) corresponding calibration dependences for terconazole in 0.1 mol L–1 phosphate buffer pH 7.2 measured on O-BDDE using in-situ activation at +2.4 V for 5 s prior each scan (○ ‒ 1st anodic peak; □ ‒ 2nd anodic peak). Error bars represent the 95 % confidence interval of the mean peak current (n=4), SE – supporting electrolyte. Conclusion In this study, the electrochemical behavior of terconazole was studied for the first time, using cyclic voltammetry and differential pulse voltammetry, on a variety of sp2 and sp3 carbon electrode materials including boron doped diamond electrode (BDD) with different surface treatment leading to O-terminated, H-terminated and polished surface, and on glassy carbon Electrode Linear dynamic range [mol L−1] Slope [nA L mol−1] Intercept [nA] R2 LD [mol L−1] O-BDDE 0.2 ‒ 4 144 ± 16.0 32 ± 19 0.988 0.40 (1st peak) 4 ‒ 100 51.9 ± 0.9 436 ± 23 0.999 ‒ O-BDDE 1 ‒ 4 36.7 ± 2.7 3.9 ± 4.6 0.995 0.87 (2nd peak) 4 ‒ 100 17.2 ± 0.3 100 ± 4 0.999 ‒ GCE 1 ‒ 100 23.8 ± 0.4 66 ± 4 0.999 0.50 PGE 1 ‒ 10 73.4 ± 5.0 406 ± 30 0.991 1.23 10 ‒ 100 36.3 ± 3.2 1109 ± 227 0.989 ‒ Journal Pre-proof Journal Pre-proof 22 and pyrolytic graphite electrodes. Measurements with all electrodes indicated similar behavior of terconazole, taking into consideration presence and potential positioning of voltammetric signals. The experiments confirmed similar interaction of terconazole and reaction intermediates with all tested surfaces, similar electron transfer kinetics and mechanism of the redox reactions. Terconazole is not directly reducible within the potential window on these electrode materials, thus our attention was paid to its oxidation in aqueous solutions in pH range from 2.0 to 12.0. Oxidation of terconazole proceeds in two steps leading to development of two anodic signals, the first one being well developed at potentials ranging from ca +0.55 V to +0.9 V, depending on the electrode used. An ECE mechanism was proposed for this signal, relying on oxidation of piperazine ring in the molecule, possessing two redox centers at the tertiary nitrogens. Different reaction pathways have been proposed for other azole agents possessing the piperazine moiety and other piperazine-based compounds. Nevertheless, the mechanisms are driven by the moieties bonded to the tertiary amines of piperazines as these influence their pKa values, as well as stability of the reaction intermediates. More extended mechanistic studies including mass-spectrometric and NMR detection of products of electrochemical oxidation are needed to confirm the suggested mechanisms and to fully understand the effects of the structural motifs surrounding the piperazine ring. The first anodic peak was used to optimize a DP voltammetric method for detection of terconazole in 0.1 mol L–1 phosphate buffer pH 7.2. The lowest detection limit of 0.40 mol L−1 was achieved on O-terminated BDD, when in-situ anodic activation was used prior to each scan assuring repeatable peak heights (RSD 1.1 %). This is beneficial in comparison with GCE and PGE with the necessity of ex-situ polishing which worsens the signal repeatability (RSD ~ 4%) of the responses and detection limits. This first study on electrochemical behaviour of terconazole clearly demonstrates the applicability of voltammetric methods or other electroanalytical approaches to its detection in various matrices of interest (e.g., pharmaceutical preparations, biological fluids) and demonstrates possibilities of carbon-based electrode materials which can be used for that purpose. The studies on the mechanism of redox reactions should be performed in a systematic way also for other piperazine-based biologically active agents to confirm structure of reaction (by)products, to evaluate the effect of the piperazine substituents, as well as to correlate the electrochemical reaction pathways with their biological activity. Acknowledgements Journal Pre-proof Journal Pre-proof 23 The project was supported by the Czech Science Foundation (project 18-01710S) and carried out within the framework of Specific University Research (SVV 260440). Authors also thank the Regional Goverment of Castilla y León, Spain, and the EU-FEDER (CLU 2017-09). References [1] K. Walayat, N.A. Mohsin, S. Aslam, M. Ahmad, An insight into the therapeutic potential of piperazine-based anticancer agents. Turk. J. Chem., 43 (2019) 1-23. https://doi.org/10.3906/kim-1806-7. [2] M. Locatelli, A. Kabir, D. Innosa, T. Lopatriello, K.G. Furton, A fabric phase sorptive extraction-High performance liquid chromatography-Photo diode array detection method for the determination of twelve azole antimicrobial drug residues in human plasma and urine, J. Chrom. B-Analyt. Technol. Biomed. Life Sci., 1040 (2017) 192-198. https://doi.org/10.1016/j.jchromb.2016.10.045. [3] M.A. Pfaller, J. Riley, T. Koerner, Effect of terconazole and other azole antifungal agents on the sterol and carbohydrate-composition of Candida albicans, Diagn. Microbiol. Infect. Dis., 13 (1990) 31-35. https://doi.org/10.1016/0732-8893(90)90050-6. [4] J.L. Thomason, Clinical evaluation of terconazole. United states experience, J. Reprod. Med., 34 (1989) 597-601. [5] M. Castro-Puyana, A.L. Crego, M.L. Marina, Enantiomeric separation of ketoconazole and terconazole antifungals by electrokinetic chromatography: Rapid quantitative analysis of ketoconazole in pharmaceutical formulations, Electrophoresis, 26 (2005) 3960-3968. https://doi.org/10.1002/elps.200500100. [6] M. Srilakshmi, S. A. Rahaman, K. Shanthakumari, Development And Validation Of UV- Spectrophotometric Method For The Estimation Of Terconazole In Bulk And Pharmaceutical Dosage Form, Indo Am. J. Pharm. Res., 3 (2013) 3057-3046. https://doi.org/10.1044/1980- iajpr.05180. [7] R.I. Elbagary, E.F. Elkady, M.H. Tammam, A.A. Elmaaty, Simultaneous Estimation of Terconazole and Benzoic Acid in Bulk and Creams Using RP-HPLC, Derivative Spectrophotometry and Chemometric Techniques, J. Chem. Pharm. Res. 9 (2017) 280-291. [8] M. Rizk, S.S. Toubar, M.M.A. El-Alamin, M.M.M. Azab, Micellar liquid chromatographic determination of sertaconazole and terconazole in bulk, pharmaceutical dosage forms and spiked human plasma, Bull. Fac. Pharm. Cairo University, 52 (2014) 155- 164. https://doi.org/10.1016/j.bfopcu.2014.03.002. [9] B.B. Chavan, G.L. Prasanna, P. Radhakrishnanand, E.R. Kosuri, P.D. Kalariya, M. Talluri, Development of a stability-indicating UPLC method for terconazole and characterization of the acidic and oxidative degradation products by UPLC-Q-TOF/MS/MS and NMR, New J. Chem., 42 (2018) 10761-10773. https://doi.org/10.1039/C8NJ00509E. [10] R. Norkova, J. Jaklova Dytrtova, M. Jakl, D. Schroder, Formation of Tebuconazole Complexes with Cadmium(II) Investigated by Electrospray Ionization Mass Spectrometry, Water Air Soil Poll., 223 (2012) 2633-2640. https://doi.org/10.1007/s11270-011-1055-7. [11] K. Novakova, T. Navratil, J. Jaklova Dytrtova, J. Chylkova, Application of Copper Solid Amalgam Electrode for Determination of Fungicide Tebuconazole, Int. J.. Electrochem. Sci., 8 (2013) 1-16. [12] J.D. Lovic, D.Z. Mijin, M.B. Jovanovic, O.S. Glavaski, T.M. Zeremski, S.D. Petrovic, M.L.A. Ivic, An investigation of tebuconazole degradation using a gold electrode, C. R. Chim., 19 (2016) 639-645. https://doi.org/10.1016/j.crci.2016.01.014. Journal Pre-proof Journal Pre-proof 24 [13] J. Fischer, H. Dejmkova, J. Barek, Electrochemistry of Pesticides and its Analytical Applications, Curr. Org. Chem., 15 (2011) 2923-2935. https://doi.org/10.2174/138527211798357146. [14] M. Moreno, E. Bermejo, A. Sanchez, M. Chicharro, A. Zapardiel, Application of matrix solid-phase dispersion to the determination of amitrole and urazole residues in apples by capillary electrophoresis with electrochemical detection, Anal. Bioanal. Chem., 391 (2008) 867-872. https://doi.org/10.1007/s00216-008-2058-0. [15] A. Shah, A.H. Shah, N. Parveen, Z.U. Rehman, S.Z. Khan, U.A. Rana, S.U.D. Khan, J. Nisar, A. Lashin, R. Qureshi, Synthesis and electrochemical investigations of piperazines, Electrochim. Acta, 220 (2016) 705-711. https://doi.org/10.1016/j.electacta.2016.10.165. [16] H. Knoth, G.K.E. Scriba, B. Buettner, Electrochemical behavior of the antifungal agents itraconazole, posaconazole and ketoconazole at a glassy carbon electrode, Pharmazie, 70 (2015) 374-378. https://doi.org/10.1691/ph.2015.4174. [17] M. Shamsipur, K. Farhadi, Adsorptive stripping voltammetric determination of ketoconazole in pharmaceutical preparations and urine using carbon paste electrodes, Analyst, 125 (2000) 1639-1643. https://doi.org/10.1039/B001452O. [18] T.Z. Peng, Q. Cheng, C.F. Yang, Adsorptive behavior and electrochemical determination of the anti-fungal agent ketoconazole, Fresenius J. Anal. Chem., 370 (2001) 1082-1086. https://doi.org/10.1007/s002160100773. [19] K. Mielech-Lukasiewicz, H. Puzanowska-Tarasiewicz, A. Niedzielko, Electrooxidation of Some Antifungal Agents and Their Square-Wave Voltammetric Determination in Cosmetics and Pharmaceutics, Anal. Lett., 44 (2011) 955-967. https://doi.org/10.1080/00032719.2010.506934. [20] J. Borowiec, L.L. Wei, L.H. Zhu, J.D. Zhang, Multi-walled carbon nanotubes modified glassy carbon electrode for sensitive determination of ketoconazole, Anal. Methods, 4 (2012) 444-448. https://doi.org/10.1039/C2AY05615A. [21] A. Shalaby, W.S. Hassan, H.A.M. Hendawy, A.M. Ibrahim, Electrochemical oxidation behavior of itraconazole at different electrodes and its anodic stripping determination in pharmaceuticals and biological fluids, J. Electroanal. Chem., 763 (2016) 51-62. https://doi.org/10.1016/j.jelechem.2015.12.047. [22] K. Mielech-Lukasiewicz, K. Roginska, Voltammetric determination of antifungal agents in pharmaceuticals and cosmetics using boron-doped diamond electrodes, Anal. Methods., 6 (2014) 7912-7922. https://doi.org/10.1039/C4AY01421A. [23] S. Baluchová, A. Taylor, V. Mortet, S. Sedlaková, L. Klimša, J. Kopeček, O. Hák, K. Schwarzová-Pecková, Porous boron doped diamond films for dopamine sensing: Effect of boron doping level on morphology and electrochemical performance, Electrochim. Acta, 327 (2019) 135025. https://doi.org/10.1016/j.electacta.2019.135025. [24] N.J. Yang, S.Y. Yu, J.V. Macpherson, Y. Einaga, H.Y. Zhao, G.H. Zhao, G.M. Swain, X. Jiang, Conductive diamond: synthesis, properties, and electrochemical applications, Chem. Soc. Rev., 48 (2019) 157-204. https://doi.org/10.1039/C7CS00757D. [25] H. Glorian, V. Schmalz, P. Lochyński, P. Fremdling, H. Börnick, E.Worch, T. Dittmar, Portable analyzer for on-site determination of dissolved organic carbon. Development and field testing, Int. J. Environ. Res. Public Health, 15 (2018) 2335. https://doi.org/10.3390/ijerph15112335 [26] L.A. Hutton, J.G. Iacobini, E. Bitziou, R.B. Channon, M.E. Newton, J.V. Macpherson, Examination of the Factors Affecting the Electrochemical Performance of Oxygen- Terminated Polycrystalline Boron-Doped Diamond Electrodes, Anal. Chem., 85 (2013) 7230- 7240. https://doi.org/10.1021/ac401042t. [27] K. Schwarzova-Peckova, J. Vosahlova, J. Barek, I. Sloufova, E. Pavlova, V. Petrak, J. Zavazalova, Influence of boron content on the morphological, spectral, and electroanalytical Journal Pre-proof