scieee AI-readable full text Open interactive document viewer

Efficient removal of siloxanes and volatile organic compounds from sewage biogas by an anoxic biotrickling filter supplemented with activated carbon

Santos Clotas, Eric,Cabrera Codony, Alba,Boada, Ellana,Gich, Frederic,Muñoz Torre, Raúl,Martín, Maria J.

Abstract

Producción Científica

Full text

1 Efficient removal of siloxanes and VOCs from sewage biogas by an anoxic biotrickling filter supplemented with activated carbon Eric Santos-Clotasa, Alba Cabrera-Codonya, Ellana Boadab, Frederic Gichb, Raúl Muñozc, Maria J. Martína* a LEQUIA, Institute of the Environment. University of Girona, Campus Montilivi, Girona 17003, Catalonia, Spain b Molecular Microbial Ecology Group (gEMM-IEA), Institute of Aquatic Ecology, University of Girona, Facultat de Ciències, Campus Montilivi, Girona 17003, Spain c Institute of Sustainable Processes, University of Valladolid, Dr. Mergelina s/n., Valladolid 47011, Spain *Corresponding author e-mail: [email protected] ABSTRACT The removal of siloxanes (D4 and D5) and volatile organic contaminants (hexane, toluene and limonene) typically found in sewage biogas was investigated in a lab-scale biotrickling filter (BTF) packed with lava rock under anoxic conditions. Complete removal efficiencies for toluene and limonene were recorded at all empty bed residence time (EBRT) tested. The influence of EBRT was remarkable on the abatement of D5, whose removal decreased from 37% at 14.5 min to 16% at 4 min, while the removal of D4 and hexane remained below 16%. The packing material was supplemented with 20% of activated carbon aiming at increasing the mass transfer of the most hydrophobic pollutants. This strategy supported high removal efficiencies of 43 and 45% for hexane and D5 at the lowest EBRT. CO2 and silica were identified as mineralization products © 2019 Elsevier. This manuscript version is made available under the CC-BY-NC-ND 4.0 2 along with the presence of metabolites in the trickling solution such as dimethylsilanediol, 2-carene and α-terpinene. KEYWORDS Activated carbon; Biogas upgrading; Biotrickling filter; Siloxanes; 1. INTRODUCTION Global warming and climate change concerns have led the EU to set the Renewable Energy Directive (2009/28/EC) aiming to reduce greenhouse gas (GHG) emissions by incentivizing renewable energies over fossil fuels. As an alternative renewable energy, biogas is a promising and versatile source of energy that originates from the anaerobic digestion of a wide spectrum of organic wastes (Alvarez-Gaitan et al., 2016; Yu and Schanbacher, 2010). In this context, the production and exploitation of this methanerich gas has increased in landfills and wastewater treatment plants (WWTP) as a result of its potential for electricity and heat production, injection into natural gas grids or use as vehicle fuel (Bachmann, 2015; Herbes et al., 2018). This renewable gas is typically composed of CH4 (35-70%), CO2 (15-50%) and low concentrations (<2%) of other biogas pollutants that influence the final use of biogas. Apart from volatile organic compounds (VOCs), siloxanes are getting an increasing attention as priority biogas pollutants. Siloxanes are a group of polymeric compounds of silicon and oxygen bonds with organic chains attached to the silicon atoms. The combustion reactions during the valorization of biogas in energy conversion systems (ERS) typically results in the transformation of volatile siloxanes into SiO2 and microcrystalline quartz. The deposition of such compounds over different engine parts mediates abrasion and a 3 deterioration in heat conduction or lubrication (de Arespacochaga et al., 2014; Soreanu et al., 2011). Adsorption technologies are the only commercially available platform for siloxanes removal, providing high removal efficiencies (Arespacochaga Santiago, 2015). Adsorption onto activated carbon (AC) or silica gel are the most widely used technology to abate siloxanes and VOCs from biogas. However, the replacement of the saturated adsorbent material entails high operational costs and environmental impacts (Cabrera-Codony et al., 2015). Emerging technologies such as biotrickling filtration (BTF) and membrane separation processes are currently under investigation to reduce the operating cost and environmental impact of conventional biogas upgrading technologies (Santos-Clotas et al., 2019a; Vergara-Fernández et al., 2018). In this sense, biotrickling filtration is based on biogas polishing using biofilms attached to inert packing materials (e.g. pall rings, lava rock) provided with nutrients and water by a trickling solution (either in co-current or counter-current mode to the biogas stream). BTF offers many advantages such as low pressure drops, simplicity in the operation and low operational costs, which make it more attractive and eco-friendlier than its physicalchemical counterparts and even than other biotechnologies (i.e. biofilters) (Malhautier et al., 2014). Despite the advantages of BTFs, the number of publications investigating siloxane removal in BTFs is scarce and limited to a reduced number of siloxanes. The few studies reported in the literature demonstrated the biodegradability (Soreanu, 2016) of these compounds under aerobic conditions. Thus, Popat and Deshusses (2008) achieved a removal efficiency (RE) of D4 of 43% at 19.5 min of EBRT and REs of 50-60% at 30-40 min with O2 as electron acceptor [7]. The same authors also investigated the 4 anaerobic removal of D4 in a BTF operated at 4 min of EBRT, obtaining a maximum RE of 15%. Likewise, Accettola et al. (2008) (Accettola et al., 2008) reported the aerobic degradation of hexamethylcyclotrisiloxane (D3) with a limited RE of 10-20% at 2-4 min of EBRT. More recently, Li et al., (2014) reported a 74% RE for D4 in an aerobic BTF operating at 13.2 min EBRT, identifying the benefits of rhamnolipids in the liquid phase produced by Pseudomonas aeruginosa. However, the low concentrations of O2 in biogas (if any at all), together with its associated explosion risk, have limited the use of aerobic biotechnologies in biogas upgrading applications. In addition, there is consistent evidence in literature demonstrating the capability of BTFs to treat VOC-laden emissions from the petrochemical industry using nitrate as an alternative electron acceptor (Akmirza et al., 2017; Almenglo et al., 2016; Muñoz et al., 2013). In this context, the co-treatment of siloxanes and VOCs in bioreactors under anoxic conditions represents an unexplored technological platform to carry out the final polishing of biogas in a cost-effective and environmental-friendly way. The low mas transfer of hydrophobic gas pollutants constitutes one of the major drawbacks challenging the bioavailability of substrates to the microorganisms and their subsequent biodegradation in biological processes (Cheng et al., 2016). In order to improve the biodegradation performance of BTFs for low water-soluble VOCs, several methods have been investigated including surfactant addition (Qian et al., 2018; Song et al., 2012; Tu et al., 2015), application of fungal biocatalysts (Zehraoui et al., 2013) and the use of hydrophilic compounds (Zehraoui et al., 2012). On the other hand, adsorption onto activated carbon is one of the most popular technologies to capture VOCs and several studies have reported on their high capacity to adsorb siloxanes. 5 The aim of the present work was to investigate the anoxic biodegradation of siloxanes (D4 and D5) in a lab-scale biotrickling filter in the presence of other biogas impurities, i.e. volatile organic compounds such as hexane, toluene and limonene. The influence of the EBRT on siloxane and VOC removal performance, along with the beneficial role of activated carbon (AC) supplementation in the BTF as a support (in order to enhance the mass transfer of biogas pollutants to the microbial community), were also investigated. 2. MATERIALS AND METHODS 2.1 BTF Inoculum Anaerobic sludge from the mixed sludge anaerobic digester of the urban wastewater treatment plant of Rubí (Barcelona, Spain) was used as precursor inoculum in the biotrickling filter. The anaerobic sludge was centrifuged at 6000 rpm for 10 min and resuspended in fresh synthetic mineral medium. This procedure was repeated several times in order to clean the sludge from dissolved organic matter. The BTF was first inoculated with 320 mL of anaerobic sludge and left recirculating for three days to promote biomass attachment to the lava rock. At day 43, the BTF was re-inoculated using a Pseudomonas aeruginosa strain isolated from anaerobic sludge samples by selective growth using the picking up method. The culture was incubated in liquid mineral salts medium containing D4 as a carbon source at 30 ºC and 125 rpm in an orbital shaker. After 72 hours, the inoculum was centrifuged and washed four times in mineral media without D4. The P. aeruginosa culture was finally re-suspended in 250 mL of synthetic mineral solution without residual organic compounds. The initial population density of P. aeruginosa culture was 4.06 × 106 cell mL-1. 6 2.2 Experimental setup A schematic of the lab-scale biotrickling filter setup designed and constructed for this study is shown in Fig. 1. The reactor consisted of a cylindrical glass column with an inner diameter of 6 cm and a total height of 46 cm. The packing material consisted of inert lava rock of 8-12 mm particle size. Different empty bed residence times of 4.0, 7.3, 10.1 and 14.5 min were evaluated. The reactor was operated in a counter-current flow configuration. A trickling solution of synthetic mineral salt medium was continuously recirculated by a peristaltic pump (Watson Marlow) from an external reservoir (250 cm3) and sprayed through the top of the bed column at a rate of 47 cm h-1. The total volume taking into account the piping as well as the reservoir accounted for roughly 400 cm3. The trickling solution in the reservoir was renewed every 72h, which represented a dilution rate of 0.3 days-1). The synthetic mineral medium used in this study was composed of: 1 g L-1 NaCl; 0.2 g L-1 MgSO4·7H2O; 0.02 g L-1 CaCl2·2H2O; 0.04 g L-1 NH4Cl; 1.16 g L-1 KH2PO4·H20; 4.76 g L-1 of HEPES buffering agent. The pH was adjusted to 6.9 using NaOH 1 M. All chemicals were obtained from PANREAC AppliChem with purities higher than 99%. Anoxic conditions were provided during the whole operation of the BTF by supplementing the mineral medium with 2 g L-1 NaNO3 (NO3- acting as the final electron acceptor). The feed gas flow was accurately regulated by a mass flow controller (Alicat Scientific) and mixed in four static mixers followed by a 1-L mixing chamber. Then, the stream was divided for the reactor inlet and a purge for analysis matters. The synthetic gas was generated by infusing the target compounds using a syringe pump (11 Elite, Harvard Apparatus) to a N2 stream previously humidified in a water column. The mixture was 7 composed of octamethylcyclotetrasiloxane (D4, 98%), decamethylcyclopentasiloxane (D5, 97%), toluene (99.8%), D-limonene (97%) and n-hexane (99%) (Sigma Aldrich). The physicochemical properties of the target pollutants and their concentration in the multicomponent gas emission are detailed in Table 1. The composition of the inlet and outlet gas emission of the BTF was analyzed via a flow-through gas sampling valve in a gas chromatograph equipped with a flame ionization detector (GC-FID, 7890B Agilent Technologies) and a HP-5ms Ultra Inert capillary column (Agilent Technologies). The oven temperature ramped from 60 ºC (1 min) to 120 ºC at 30 ºC min-1, then to 150 ºC at 10 ºC min-1, and finally to 300 ºC at 50 ºC min-1 and held for 3 min. The injector temperature was set at 240 ºC with helium (99.99% Abelló Linde, Spain) at a split ratio 1:6. Calibration was carried out using external standards prepared in the above described continuous set-up. Routine analysis of the inlet and outlet gas streams was performed in triplicate (coefficient of variation < 6%). 2.3 Operating conditions The operation of the BTF was divided into four stages related to the carbon source provided in the gas stream and the type of packing material used in the BTF. Stage I (days 0-42) operated with a N2 stream containing D4 at 62 ± 2 mg m-3 supplied at an EBRT of 14.5 min. In stage II (days 43-152), the target pollutant was switched to a multicomponent mixture of siloxanes (D4 and D5) and VOCs (hexane, toluene and limonene) in the concentrations described in Table 1. These biogas pollutants were selected based on an exhaustive database set up by Papadias et al., (2011) of published data on impurities found in the biogas produced by anaerobic digestion of sewage 8 sludge. Nearly 300 biogas contaminants were included and classified in different categories, with special attention into their concentration range. The most representative compounds among the most important biogas pollutant categories were selected: hexane from the class of alkanes, limonene from the class of cyclic hydrocarbons, toluene from the class of aromatic hydrocarbons, and D4 and D5 from the class of siloxanes. During stage II, the influence of the EBRT (14.5, 10.1, 7.3 and 4 min) on the removal efficiency and elimination capacity of the target biogas contaminants was tested. The EBRT were selected according to literature (Popat and Deshusses, 2008) aiming at minimizing the reactor size required for siloxane biodegradation. In stage III (days 153- 186), 35 g of a wood-based chemically activated carbon in pellet size (2-3 mm particle size) were added at the top of the packed bed, which accounted for a layer of approximately 5 cm of packing bed. The AC used in the present study was selected due to its high siloxane adsorption capacity as well as its capacity to transform siloxanes into α-ω-silanediols in the presence of moisture (Cabrera-Codony et al., 2018; Santos- Clotas et al., 2019b) Finally, the packing lava rock was removed from the column, and the biofiltration process was performed with the 5 cm layer of AC (introduced during Stage III) as the only packing bed (Stage IV, days 187-207). During stage II-4 and stage IV, the influence of the trickling solution dispersion on the performance of the BTF was evaluated by stopping (5 h) and re-starting the recirculation of the trickling solution. During these events, the outlet gas stream of the BTF was continuously monitored by GC-FID. An abiotic test was initially carried out to evaluate the physicochemical removal of siloxane D4 in the experimental set-up. Additional abiotic tests using the multicomponent gas mixture were performed in parallel lab-scale BTF. 9 2.4 Metabolites analysis and identification 2.4.1 Outlet emission The BTF outlet gas was analyzed by GC-MS (7890B GC-5977B MS, Agilent Technologies) in order to identify CO2 and volatile biodegradation products. CO2 was determined by monitoring the ion with m/z 44 and calibration standards were prepared by diluting CO2 (99.99%, Abelló Linde, Spain) to N2. Limonene metabolites were identified by GC-MS analysis by comparing the m/z of the metabolites with those in the NIST library, and by injecting pure reagents (if commercially available) for further confirmation. 2.4.2 Trickling solution Identification of the biodegradation metabolites in the trickling solution was carried out by GC-MS (7890B GC-5977B MS, Agilent Technologies). Silanediols determination procedure is reported elsewhere (Cabrera-Codony et al., 2017). Silicic acid was measured by means of a colorimetric test in which dissolved silicic acid reacted with ammonium molybdate under acid conditions producing the yellow complex molybdosilicate acid. Oxalic acid was added to avoid the formation of molybdophosphate acid and therefore the interference of phosphates. The absorbance of the resulting samples was measured at 410 nm in a spectrophotometer (3100PC, VWR, USA). Total silicon concentration was analyzed by means of inductively coupled plasma-optical emission spectroscopy (ICP-OES, Agilent 5100). 2.4.3 Packing media Samples of the lava rock and activated carbon were taken at different times for Scanning Electron Microscope (SEM) analysis in order to observe the biomass grown in 16 EBRT decreased to 2 min (Stage IV). In this context, while toluene removal was complete, limonene RE decreased to 78% at the beginning of stage IV. This initial decrease in the RE of this monoterpene was likely mediated by the absence in the AC of a microbial community capable of degrading limonene, which was completely degraded throughout the lava rock layer during Stage II, and therefore prevented the exposure of the top AC-layer to limonene in Stage III. Thus, the microbial community already acclimated to limonene was also cleared from the BTF when removing the lava rock. However, the RE of limonene reached 100 % within the next 3 days from re-packing of the BTF, which highlighted the high robustness of the system and the rapid acclimation of the microbial community to VOCs. The lava rock evacuation and its associated decrease in the EBRT to 2 min resulted in a sharp decrease in D5 removal efficiency from 43% at the beginning of stage IV to steady stated values of 22. D5 abatement in the BTF during steady state was likely due to a combination of microbial degradation boosted by an enhanced siloxane adsorption and hydrolysis mediated by the activated carbon. Overall, the BTF packed with a thin layer of activated carbon (corresponding to an EBRT of 2 min) achieved comparable removal efficiencies to those recorded in the BTF packed with a 6 times larger of lava rock bed (Fig. 3, EBRT 14.5 min). The AC was an effective packing material for cell attachment as well as an efficient packing material for the final polishing of biogas. This study also confirmed that a short bed of AC (i.e. low EBRT) would entail smaller bioreactor volume than the lava rock, which will significantly decrease the capital and operating cost of biogas. The results herein obtained also suggest that a supplementary adsorption treatment would be required for complete siloxanes removal. The complete removal achieved for the target VOCs in the lava rock bed is particularly relevant since toluene and limonene are major competitors 17 for adsorptive sites in current biogas adsorption technologies (Cabrera-Codony et al., 2018). A complete VOC removal in an anoxic BTF prior a final adsorption polishing step, together with the partial siloxane biodegradation, might extend the lifetime of adsorption filters, which would ultimately decrease the operational costs of biogas upgrading. 3.5 Processes governing siloxane removal In stages II and III the GC-MS analysis of the outlet gas did not detect significant amount of volatile metabolites. In this context, the trickling solution was analyzed to determine the presence of soluble transformation products during the operation with lava rock (Stage II-4) and lava rock and AC (Stage III). Acid silicic concentrations of 7.3 and 10.6 mg Si L-1 were recorded during stage II-4 and III, respectively. Moreover, GC-MS qualitative analysis revealed the presence of dimethylsilanediol (DMSD), tetramethyl-1,3-disiloxanediol and hexamethyl-1,5-trisiloxanediol (Table 2) in the trickling liquid of stage III. Only the first two silanediols compounds were identified at lower concentrations in the trickling solution during stage II-4. These results agree with the higher removal efficiency of D5 achieved under BTF operation with an activated carbon packed bed. This siloxane transformation products are formed by both i) bond cleavage of D4 and D5 through hydrolysis reactions promoted by AC’s functional groups, and ii) biodegradation of larger α-ω-silanediols, D4 and D5. Thus, the higher concentration found was the consequence of both the AC catalytic activity and biodegradation, which would eventually support the hypothesis of the ability of ACs to catalyze the ring-opening of cyclic siloxanes and thus boost siloxane degradation (Cabrera-Codony et al., 2014). Since silanediols could not be quantified due to lack of 18 commercial reagents, total Si analysis were performed by ICP-OES aiming at closing the Si mass balance. Si contents of 13.2 and 21.8 mg L-1 were obtained in the trickling solution of Stages II-4 and III, respectively. For the mass balance, it was taken into account that the liquid samples were collected after 3 days (when the recirculation media was replaced) and a total liquid volume of roughly 400 cm3. The Si analyses accounted for a 22 and 36% of the total Si that entered the reactor and was found dissolved in the recirculation liquid of Stages II-4 and III, respectively. Moreover, according to the average REs obtained for both D4 and D5 in the different stages, a 74 and 65% of Si was found in the outlet emissions in Stage II-4 and III, respectively, which mostly completed the Si mass balance. The remaining percentage of Si to reach 100 was below 4% in both stages, which could be attributed to the inlet concentration stability as well as the accurate liquid volume in the system. In this context, siloxane removal was likely due to mainly biodegradation in stage II-4. In stage III biodegradation would still be the major process involved, though boosted by transformation reactions due to the AC surface, as observed with the higher presence of Silicon soluble species. On the other hand, in stage IV the use of activated carbon as biomass support drastically increased the elimination capacity of siloxanes (Fig. 2). Thus, the removal efficiency of the system remained stable despite the reduction of the EBRT from 14.5 min (Stage I) to 2 min. In order to get a further insight on the mechanisms governing siloxane removal, activated carbon samples were collected at the end of Stage IV to analyze the compounds adsorbed or retained in the biofilm. THF extraction was performed following the experimental procedure previously described (Cabrera-Codony et al., 2018). The results showed that the siloxane retained in the solid phase was in a 19 concentration below the quantification limit (<0.5 mg m-3). Considering the total volume of the packing material and the amount of siloxane circulated during the whole stage, both physicochemical adsoption and biosorption of siloxane removal could be ruled out. While no volatile silicon byproducts were detected in the gas outlet, the CO2 production during Stage IV was monitored. An average concentration of CO2 up to 405 ppmv was detected, which corresponded to 21 g h-1 mreactor-3. This CO2 production corresponded to an average pollutant mineralization of 80% considering both the siloxanes and VOCs removed. Such incomplete mineralization determined by the CO2 analysis could be linked to the accumulation of methyl-siloxane by-products in the liquid phase as well as the growth of new biomass. Therefore, these results supported the hypothesis that biodegradation was the predominant process involved in the removal of VOCs and siloxanes. 3.6 Robustness of AC as BTF support In order to assess the impact of the trickling solution dispersion on the performance of the BTF, the recirculation of the trickling solution was paused during periods of ca. 5 hours and re-started. While toluene and limonene were completely removed during the trickling dispersion period, both biogas pollutants were detected in the exhaust gas in the absence of mineral medium dispersion likely due to the limitation in nitrate availability, which was the only final electron acceptor in the biodegradation process. Moreover, biodegradation metabolites from the incomplete mineralization of limonene were detected in the outlet emission. Fig. 5A depicts the outlet/inlet areas ratios (C/C0) 20 for toluene, limonene and metabolites during the stop and resumption of the trickling solution. After 5 h of trickling solution shutdown, the C/Co ratios for toluene and limonene reached 0.7 and 0.46, while a complete removal of both pollutants and metabolites was recorded after the resumption of liquid distribution. GC-MS analysis of the outlet gas in the absence of trickling medium dispersion identified 2-carene and αterpinene (Table 2) as the main metabolites released during the incomplete oxidation of limonene in the absence of NO3-. Moreover, a qualitative analysis by GC-MS of the trickling solution revealed traces of p-cymene, which could have also originated from the partial oxidation of limonene. On the other hand, Fig. 5B shows the performance of the BTF packed with activated carbon (stage IV) during an event of trickling dispersion stoppage. During the 5-hour trickling solution shutdown, the removal efficiency of both toluene and limonene remained at 100 % and no metabolite was detected in the outlet gas emission. It needs to be highlighted that, as visually noticed, the carbon layer remained highly humidified during the period without mineral medium distribution, which was not observed during the same experiment with lava rock. This finding suggested that the porous AC was capable of retaining sufficient amount of trickling solution to provide the biofilm with the necessary compounds to maintain microbial activity during periods without trickling solution distribution. Using AC as packing material in anoxic BTF may guarantee a sustained electron acceptor availability to the biofilm compared to conventional packing media, which are dependent on stable dispersion conditions. 4. CONCLUSIONS This study confirmed the potential of biotrickling filtration to remove siloxanes and VOC under anoxic conditions. Toluene and limonene were effectively degraded at all 21 the EBRT tested. The use of activated carbon as packing material to overcome mass transfer limitation encountered for hexane, D4 and D5 supported an effective biomass growth, while promoting hydrolysis reactions leading to soluble silanediols. Furthermore, AC supplementation enabled the BTF operation at reduced EBRTs, which would ultimately decrease the operating and investment cost of biogas purification. This study also demonstrated a high robustness towards variations in the EBRT and interruptions in the trickling solution distribution. E-supplementary data for this work can be found in e-version of this paper online Funding: This work was funded by the Spanish Ministry of Science, Innovation and Universities (CTQ2014-53718-R) co-funded by FEDER and University of Girona. Eric Santos-Clotas thanks Universitat de Girona for his predoctoral grant (IFUdG-2015/51). Ellana Amparito Boada Cahueñas thanks SENESCYT – Ecuador for her predoctoral grant. Alba Cabrera-Codony acknowledges support from the European Union’s Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement Nº 712949 (TECNIOspring PLUS) and from the Agency for Business Competitiveness of the Government of Catalonia (TECSPR16-1-0045). LEQUIA and IEA have been recognized as consolidated research groups by the Catalan Government (2017-SGR-1552 and 2017SGR-548, respectively). Acknowledgements: We thank STR-UdG for their support with SEM examinations and ICP-OES analysis. Declaration of interests: The authors declare no conflict of interests. 22 5. REFERENCES 1. Accettola, F., Guebitz, G.M., Schoeftner, R., 2008. Siloxane removal from biogas by biofiltration: Biodegradation studies. Clean Technol. Environ. Policy 10, 211–218. https://doi.org/10.1007/s10098-007-0141-4 Akmirza, I., Pascual, C., Carvajal, A., Pérez, R., Muñoz, R., Lebrero, R., 2017. Anoxic biodegradation of BTEX in a biotrickling filter. Sci. Total Environ. 587–588, 457– 465. https://doi.org/10.1016/j.scitotenv.2017.02.130 Almenglo, F., Ramírez, M., Gómez, J.M., Cantero, D., 2016. Operational conditions for start-up and nitrate-feeding in an anoxic biotrickling filtration process at pilot scale. Chem. Eng. J. 285, 83–91. https://doi.org/10.1016/j.cej.2015.09.094 Alvarez-Gaitan, J.P., Short, M.D., Lundie, S., Stuetz, R., 2016. Towards a comprehensive greenhouse gas emissions inventory for biosolids. Water Res. 96, 299–307. https://doi.org/10.1016/j.watres.2016.03.059 Arespacochaga Santiago, N. de, 2015. Sewage biogas energy valorization via solid oxide fuel cells. TDX (Tesis Dr. en Xarxa). Bachmann, N., 2015. Sustainable biogas production in municipal wastewater treatment plants. IEA Bioenergy 20. Boada, E., Santos-Clotas, E., Cabrera-Codony, A., Martin, M.J., Bañeras, L., Gich, F., 2018. Isolation of bacterial species with potential capacity siloxane removal in biogas upgrading, in: 2nd International Conference on Bioresource Technology for Bioenergy, Bioproducts & Environmental Sustainability (BIORESTEC2018). Sitges, Spain. Cabrera-Codony, A., Georgi, A., Gonzalez-Olmos, R., Valdés, H., Martín, M.J., 2017. Zeolites as recyclable adsorbents/catalysts for biogas upgrading: Removal of octamethylcyclotetrasiloxane. Chem. Eng. J. 307. https://doi.org/10.1016/j.cej.2016.09.017 Cabrera-Codony, A., Gonzalez-Olmos, R., Martín, M.J., 2015. Regeneration of siloxane-exhausted activated carbon by advanced oxidation processes. J. Hazard. Mater. https://doi.org/10.1016/j.jhazmat.2014.11.053 Cabrera-Codony, A., Montes-Morán, M.A., Sánchez-Polo, M., Martín, M.J., Gonzalez- Olmos, R., 2014. Biogas upgrading: Optimal activated carbon properties for siloxane removal. Environ. Sci. Technol. 48. https://doi.org/10.1021/es501274a Cabrera-Codony, A., Santos-Clotas, E., Ania, C.O., Martín, M.J., 2018. Competitive siloxane adsorption in multicomponent gas streams for biogas upgrading. Chem. Eng. J. 344. https://doi.org/10.1016/j.cej.2018.03.131 Cheng, Y., He, H., Yang, C., Zeng, G., Li, X., Chen, H., Yu, G., 2016. Challenges and solutions for biofiltration of hydrophobic volatile organic compounds. Biotechnol. Adv. 34, 1091–1102. https://doi.org/10.1016/j.biotechadv.2016.06.007 de Arespacochaga, N., Valderrama, C., Mesa, C., Bouchy, L., Cortina, J.L., 2014. Biogas deep clean-up based on adsorption technologies for Solid Oxide Fuel Cell applications. Chem. Eng. J. 255, 593–603. https://doi.org/10.1016/j.cej.2014.06.072 23 Herbes, C., Halbherr, V., Braun, L., 2018. Factors influencing prices for heat from biogas plants. Appl. Energy 221, 308–318. https://doi.org/10.1016/j.apenergy.2018.03.188 Kalkan, Ç., Yapsakli, K., Mertoglu, B., Tufan, D., Saatci, A., 2011. Evaluation of Biological Activated Carbon ( BAC ) process in wastewater treatment secondary ef fl uent for reclamation purposes. DES 265, 266–273. https://doi.org/10.1016/j.desal.2010.07.060 Li, Y., Zhang, W., Xu, J., 2014. Siloxanes removal from biogas by a lab-scale biotrickling filter inoculated with Pseudomonas aeruginosa S240. J. Hazard. Mater. 275, 175–184. https://doi.org/10.1016/j.jhazmat.2014.05.008 Malhautier, L., Quijano, G., Avezac, M., Rocher, J., Fanlo, J.L., 2014. Kinetic characterization of toluene biodegradation by Rhodococcus erythropolis: Towards a rationale for microflora enhancement in bioreactors devoted to air treatment. Chem. Eng. J. 247, 199–204. https://doi.org/10.1016/j.cej.2014.02.099 Muñoz, R., Arriaga, S., Hernández, S., Guieysse, B., Revah, S., 2006. Enhanced hexane biodegradation in a two phase partitioning bioreactor: Overcoming pollutant transport limitations. Process Biochem. 41, 1614–1619. https://doi.org/10.1016/j.procbio.2006.03.007 Muñoz, R., Souza, T.S.O., Glittmann, L., Pérez, R., Quijano, G., 2013. Biological anoxic treatment of O2-free VOC emissions from the petrochemical industry: A proof of concept study. J. Hazard. Mater. 260, 442–450. https://doi.org/10.1016/j.jhazmat.2013.05.051 Papadias, D., Ahmed, S., Kumar, R., 2011. Fuel Quality Issues in Stationary Fuel Cell Systems. Popat, S.C., Deshusses, M. a., 2008. Biological removal of siloxanes from landfill and digester gases: Opportunities and challenges. Environ. Sci. Technol. 42, 8510– 8515. https://doi.org/10.1021/es801320w Qian, H., Cheng, Y., Yang, C., Wu, S., Zeng, G., Xi, J., 2018. Performance and biofilm characteristics of biotrickling filters for ethylbenzene removal in the presence of saponins. Environ. Sci. Pollut. Res. 25, 30021–30030. https://doi.org/10.1007/s11356-017-0776-6 Rahman, K.S.M., Rahman, T.J., McClean, S., Marchant, R., Banat, I.M., 2002. Rhamnolipid biosurfactant production by strains of Pseudomonas aeruginosa using low-cost raw materials. Biotechnol. Prog. 18, 1277–1281. https://doi.org/10.1021/bp020071x Rościszewski, P., Łukasiak, J., Dorosz, A., Galiński, J., Szponar, M., 1998. Biodegradation of polyorganosiloxanes. Macromol. Symp. 130, 337–346. https://doi.org/10.1002/masy.19981300129 Santos-Clotas, E., Cabrera-Codony, A., Castillo, A., Martín, M.J., Poch, M., Monclús, H., 2019a. Environmental Decision Support System for Biogas Upgrading to Feasible Fuel. Energies 12, 1546. https://doi.org/10.3390/en12081546 Santos-Clotas, E., Cabrera-Codony, A., Ruiz, B., Fuente, E., Martín, M.J., 2019b. Sewage biogas efficient purification by means of lignocellulosic waste-based 24 activated carbons. Bioresour. Technol. 275, 207–215. https://doi.org/10.1016/j.biortech.2018.12.060 Song, T., Yang, C., Zeng, G., Yu, G., Xu, C., 2012. Effect of surfactant on styrene removal from waste gas streams in biotrickling filters. J. Chem. Technol. Biotechnol. 87, 785–790. https://doi.org/10.1002/jctb.3717 Soreanu, G., 2016. Insights into siloxane removal from biogas in biotrickling filters via process mapping-based analysis. Chemosphere 146, 539–546. https://doi.org/10.1016/j.chemosphere.2015.11.121 Soreanu, G., Béland, M., Falletta, P., Edmonson, K., Svoboda, L., Al-Jamal, M., Seto, P., 2011. Approaches concerning siloxane removal from biogas - A review. Can. Biosyst. Eng. / Le Genie des Biosyst. au Canada 53. Tu, Y., Yang, C., Cheng, Y., Zeng, G., Lu, L., Wang, L., 2015. Effect of saponins on nhexane removal in biotrickling filters. Bioresour. Technol. 175, 231–238. https://doi.org/10.1016/j.biortech.2014.10.039 Vergara-Fernández, A., Yánez, D., Morales, P., Scott, F., Aroca, G., Diaz-Robles, L., Moreno-Casas, P., 2018. Biofiltration of benzo[Α]pyrene, toluene and formaldehyde in air by a consortium of Rhodococcus erythropolis and Fusarium solani: Effect of inlet loads, gas flow and temperature. Chem. Eng. J. 332, 702– 710. https://doi.org/10.1016/j.cej.2017.09.095 Xu, L., Shi, Y., Cai, Y., 2013. Occurrence and fate of volatile siloxanes in a municipal Wastewater Treatment Plant of Beijing, China. Water Res. 47, 715–724. https://doi.org/10.1016/j.watres.2012.10.046 Yu, Z., Schanbacher, F.L., 2010. Production of Methane Biogas as Fuel Through Anaerobic Digestion, in: Singh, O. V, Harvey, S.P. (Eds.), Sustainable Biotechnology: Sources of Renewable Energy. Springer Netherlands, Dordrecht, pp. 105–127. https://doi.org/10.1007/978-90-481-3295-9_6 Zehraoui, A., Hassan, A.A., Sorial, G.A., 2013. Biological treatment of n-hexane and methanol in trickle bed air biofilters under acidic conditions. Biochem. Eng. J. 77, 129–135. https://doi.org/10.1016/j.bej.2013.06.001 Zehraoui, A., Hassan, A.A., Sorial, G.A., 2012. Effect of methanol on the biofiltration of n-hexane. J. Hazard. Mater. 219–220, 176–182. https://doi.org/10.1016/j.jhazmat.2012.03.075 25 Figure captions: Fig. 1. Biotrickling filter setup (1 Syringe pump; 2 and 3 Mass flow controllers; 4 Water column; 5 Static mixers; 6 Mixing chamber; 7 Biotrickling filter; 8 Mineral media tank; 9 Peristaltic pump; 10 and 11 Sampling points). Fig. 2. Time course of removal efficiency (RE, ●) and elimination capacity (EC, □) of hexane (A), toluene (B), limonene (C), D4 (D), and D5 (E) in the biotrickling filter. Vertical dashed lines represent changes in the operational conditions: empty bed residence times (EBRT) from 14.5>10.1>7.3>4 min, activated carbon addition (AC) and lava rock (LR) withdrawal. Fig. 3. Effect of the empty bed residence time on the removal efficiency (A) and elimination capacity (B) of D4 (●), D5 (○), toluene (▲), limonene (□) and hexane (×). Fig. 4. (A) Effect of the addition of activated carbon at day 153 in Stage III (represented by the dashed line) on the outlet stream concentrations of hexane (○), D4 (●) and D5 (□). Fig. 5 Time-course of toluene (▲) and limonene (□) and the Gas Chromatograph response in area units of the metabolites (●) in the outlet gas, vertical dashed lines indicate the stoppage of the trickling recirculation, and vertical solid lines display the restart of the recirculation. Data corresponding to stage II-1 with lava rock as packing material (A) and stage IV with AC (B).