1 From the point cloud to knowledge. Geometry, metrics 1 and construction of the cloister of the Cathedral of 2 Tarragona 3 4 Josep M. Puche (*), M. Amparo Núñez-Andrés (**), Agustí Costa-Jover (***), Josep M. Macias 5 (****), Felipe Buill Pozuelo(*****), David Moreno-García (******) 6 7 (*) Catalan Institute of Classical Archaeology Tarragona (Spain) 8 (**) Department of Civil and Environmental Engineering, Polytechnic University of Catalonia, 9 Barcelona (Spain) 10 (***) Department of Architecture, Rovira i Virgili University, Reus (Spain) 11 (****) Catalan Institute of Classical Archaeology Tarragona (Spain) 12 (*****) Department of Civil and Environmental Engineering. Polytechnic University of Catalonia, 13 Barcelona (Spain) 14 (******) Department of Architecture, Rovira i Virgili University, Reus (Spain) 15 16 Corresponding author: Dr. Josep M. Puche (
[email protected]) 17 18 ORCID: http://orcid.org/0000-0002-8674-2966 (Josep M. Puche); http://orcid.org/0000-0003-2745- 19 7759 (M Amparo Núñez-Andrés); http://orcid.org/0000-0002-6194-3243 (Agustí Costa-Jover); 20 http://orcid.org/0000-0002-1146-7015 (Josep M. Macias); http://orcid.org/0000-0002-9222-0072 21 (Felipe Buill Pozuelo); http://orcid.org/0000-0002-5322-8143 (David Moreno-García) 22 23 24 25 ABSTRACT 26 27 The availability of dense point clouds for the assessment of ancient buildings has become reality in 28 recent decades. This continuous and detailed information facilitates an analysis of cultural heritage 29 as it had not been possible to carry out previously. Thus, it is possible to study their shape and metrics, 30 giving a new interpretative analysis and set, for example, new hypothesis of their constructive 31 evolution. In this sense, the research aims to apply formal analysis methods based on point clouds in 32 the case of the cloister of the Cathedral of Tarragona, due to its unique characteristics and the 33 existing documentary void on its construction history. It is a monumental enclosure characterised by 34 an irregular plan and various apparent constructive inconsistencies that are due to different phases 35 of execution. From its metric and formal analysis, various hypotheses of its constructive evolution 36 are raised. 37 38 39 Keywords: point clouds; metric analysis; building analysis; Tarragona cathedral. 40 41 42 1. OBJECTIVE AND CONTEXT OF THE RESEARCH 43 44 The cloister of the Cathedral of Tarragona stands out for the notable formal anomalies of its 45 construction elements. Its design and location are based on the reuse of a pre-existing Roman wall in 46 the north corner, but this fact alone does not explain the anomalies detected. Metric and formal 47 analysis using a terrestrial laser scanner survey has provided new hypotheses about its construction 48 process. It is a complex Romanesque-Gothic cathedral due to its size and execution time, which 49 required different phases and modifications during its implementation. A metric and modular 50
2 structuring of its galleries and adjacent rooms has been proposed as an interpretative basis for the 51 specific peculiarities of an enclosure. It was materialised under the overall Cathedral construction 52 process and adapted to two different realities. On the one hand, the urban pre-existence of the Roman 53 period and, on the other, the functional and architectural connection with the monastic community 54 that managed the episcopal see during the building process. 55 We start from a broader multidisciplinary research on the Cathedral that has already advanced results 56 (Buill et al., 2020), while complementing the archaeological research and architectural and liturgical 57 approaches (Macias et al., 2007; Macias Solé et al., 2012). The extensive bibliography available 58 shows the interest generated by the construction of the mediaeval Seo. It was not only a building 59 process of adaptation and superimposition on the monumental remains of the Imperial Worship 60 Temple. In this case, it was in the capital of the largest province of the Roman Empire (Gerardo Boto, 61 2016; Serrano, 2018). The architectural design and the elevation process of the Romanesque cloister 62 was also a consequence of the intrinsic urban evolution of the Cathedral complex and its 63 representative and symbolic function in its historical context. 64 65 Figure 1. Cathedral of Tarragona ground floor plan, showing the location of the Temple of 66 Augustus and the Roman temenos. 67 The sacred pagan precinct and the Christian temple reflect, each in its own time, the desire to crown 68 and preside over the hill of Tarragona. They were the ultimate expression of the pseudo-theocratic 69 power of the Roman emperor during the 1st century AD, and later of the all-powerful metropolitan 70 archbishop and feudal lord of the city during its Christian repopulation. With the new cathedral, the 71 emerging Catalan counties consecrated their independence from the metropolitan Seo of Narbonne 72 and "restored the established order" interrupted for centuries by the domination of the Šarq Al- 73 Andalus. 74
3 The new Romanesque cathedral represents the iron will of continuity of religious power in the urban 75 scenography. It was the proof of the historical legitimisation of a primate Ecclesia Tarraconensis that 76 had already occupied this site in the Visigothic period. This cathedral was built on the same axis of 77 symmetry as the temple of Augustus and was projected over the mediaeval city that occupied the 78 lower urban terrace (Figure 1). For a better view, the cathedral façade was moved forward in relation 79 to the temple of Augustus. The width of the church led to an atypical position of the cloister, which 80 was pushed back to the north of the eastern arm of the transept. At this point, the architectural reuse 81 of the closing wall of the roman temenos is well known. The cloister was cornered in the north-eastern 82 corner of the ancient roman square with a surface area of 2 hectares. This was not only an urbanistic 83 solution, but also a functional one, because the large Roman corridor excavated in the rock, outside 84 the sacred square, determined the location of the perimeter rooms of the Cloister (Macias et al., 2007). 85 In this sense, we cannot dissociate the architectural design of the cloister from the functional needs 86 of the Augustinian canonry. This was responsible for the functioning and worship of the cathedral 87 from 1154 onwards. The refectory, the chapterhouse, the bedroom and other rooms were 88 contemplated in the cloister plain and their urban and ceremonial fit with the Cathedral was 89 obligatory. 90 Summarising, the aim of this research is to base on the laser scan survey to study the metrics and 91 dimensions of the cloister linking with the historical knowledge of the construction. 92 93 2. THE CLOISTER OF THE CATHEDRAL OF TARRAGONA 94 95 2.1. Periodization, urban planning and context of the research 96 97 Historiography and architectural analysis have allowed us to periodise the construction process of the 98 Cloister (Gerardo Boto, 2016), whose N and W limits were adapted to the corner of the Roman 99 temenos. Its peribolos was an opus quadratum wall about 85 cm thick, which was then about 8 metres 100 high. The southern edge of this praecint was defined by the construction of the monastic refectory, 101 which was 39 m long (according to the original eastern enclosure) and 15.49 m wide. Thus, the N 102 outer wall of the refectory was the S boundary of the cloister, located parallel to 46.40 m of the N 103 wall of the Roman temenos (Figure 2). 104
4 105 Figure 2. Cloister of Tarragona Cathedral ground floor plan, and numbering of the bays for the 106 study. 107 Thus, with two Roman and one mediaeval wall, the interior area of the cloister was delimited, while 108 its monastic rooms were distributed around it. The North and West rooms were adapted to the Roman 109 cut-outs in the mountain and the refectory was built with a thick nave with a barrel vault. At the same 110 time, the construction of the adjoining cathedral nave began in the mid-12th century, during the 111 bishopric of Hug de Cervelló (1163-1171). 112 Its axis of symmetry coincided with that of the great Roman square and its design provided, from 113 different spaces, the eastern edge of the cloister. This took place around 1184 when the construction 114 of the Cathedral's chevet was completed. The chevet consisted of five apses and, next to the cloister, 115 the chapterhouse and sacristy were added. In this way, a quadrangular enclosure measuring 47.50 m 116 by 46.50 m was designed, but with problems of urban connection between the transept of the 117 Cathedral and the SE corner of the cloister (Gerardo Boto, 2016). Consequently, the westernmost 118 apse was never completed as it intersected with the refectory and the adjoining cloister corner. 119
5 120 121 Figure 3. South gallery and connecting doorway to the cathedral. Corresponds to bays 1 to 4. 122 123 The cloister galleries construction began during the Bernat Tort’s archbishopric, between 1146 and 124 1163, and were completed at the beginning of the 13th century, when Ramon de Rocabertí was 125 archbishop. The cloister occupied a practically square space, with a surface area of about 2.2m2. It 126 was bounded by the refectory, the North-West corner of the ancient Roman temenos, and the limit of 127 cathedral chevet and the chapterhouse. It was organised into 28 bays (8 per arm), covered with a 128 ribbed vault with an approximate width of 5.60 m. To facilitate the understanding of the narrative 129 discourse, these bays have been numbered in a clockwise direction, starting from bay S-E, which is 130 where the portal leading to the cathedral is located (Figure 3). 131 The bays are separated by pointed arches, and the gallery opens to the inner courtyard with another 132 pointed arch, partially enclosed by three rounded arches supporting a wall with two rounded openings. 133 134 The external perimeter of the galleries varies according to the previous constructions that delimit it. 135 Thus, in the S arm, the bays rest directly on the refectory wall, embedding the arches' corbels inside 136 it. Instead, in the W and N arms, a new wall was built to cover the roman peribolos. Finally, the E 137 arm rests directly on a wall that connects the chapter house with the cathedral's entrance door. 138 Thus, despite being developed within a perfectly rectangular space, its eastern arm shows an 139 inclination of approximately 2º 20', breaking the orthogonality that prevails both in the rest of the 140 cloister and in the cathedral itself. There is also an alignment deviation of the eastern end of the 141 southern gallery, made, with complete security, to be able to fit this corridor with the connection door 142 with the cathedral, which is wider. 143 From a planimetric point of view, this cloister is characterised by the numerous irregularities detected 144 in it. Thus, despite being developed within a perfectly rectangular space, its eastern arm presents an 145 inclination of approximately 2º 20 ', breaking with the orthogonality that prevails both in the rest of 146 the cloister and in the cathedral itself. There is also a widening at the east end of the south gallery, 147 which was probably made to fit this corridor with the wider entrance that connects to the cathedral. 148 Despite the bays are quite homogeneous in width, vary in length, ranging from 5.06 m to 6.47 m. Five 149 of them (bays 1, 2, 22, 23 and 28) are clearly trapezoidal. The other bays show a slightly orthogonal 150 plan. 151 152
6 3. METHODOLOGY 153 154 Previous studies have already demonstrated the importance of metric analysis as a tool for the study 155 and understanding of historical architecture. Thus, for example, the problem about the historical 156 authenticity of the alleged Romanesque cloister of Mas dels Vents in Palamos (Gerona, Spain) was 157 solved, not from the stylistic analysis but thanks to the metric, as it was established that contemporary 158 and not mediaeval patterns were established (Carbonell 2014, 22-93). Aware of the importance of the 159 metrics, we have sought a documentation methodology that guarantees good quality and reliability 160 of the data obtained. Our own experience, and other similar works, among others (Jiménez 2015, 161 Giannetti 2013), determined that the best way was to use the so-called Massive Data Capture Systems. 162 By the other hand, the Siena-Florence school of mediaeval architectural studies has already 163 established the methodological bases for the study of metric and modulation of historic buildings 164 (Mannoni and Milanese 1988) and the need to contextualise metrics at the historical level (Bartoli 165 2009). Recent studies have demonstrated the validity and usefulness of applying this methodology, 166 obtaining innovative and interesting results (Roldan et al. 2020; Moyano et al. 2017; Espejo 2021). 167 To achieve the proposed objective, it was necessary to obtain metric information, both in planimetry 168 and altimetry, of all the cloister's bays. This information could be gathered using discrete methods, 169 i.e., by measuring the relevant points with a total station, or through mass data capture methods, such 170 as terrestrial laser scanning (TLS) or digital photogrammetry. 171 In the first case, we have the advantage of being able to precisely identify the exact point where the 172 measurement is taken, with high absolute and relative accuracy. However, when working with ancient 173 heritage structures, especially those exposed to the elements, this can be challenging due to rounded 174 edges and vertices. Additionally, if further measurements are required to complete the study, a new 175 survey campaign would be necessary. 176 This drawback does not exist if a complete 3D model is available, obtained from a close-range 177 photogrammetric survey or high-resolution TLS. In this case, it is more difficult to identify the same 178 point in each bay, but it can be done with sufficient accuracy for our objective. When using TLS, a 179 balance must be struck between the resolution necessary to achieve the required level of element 180 identification in the study and the amount of measured points that allows for proper point cloud 181 management from a computational perspective. The level of detail obtained will be sufficient and 182 comparable to that of photogrammetry, which is why a laser scanning survey has been chosen. 183 We have used a mid-range terrestrial laser scanner, model Leica RTC360. A total of 55 positions was 184 carried out, from which the visible details were captured obtaining 3D point clouds. All of them were 185 registered in the same coordinate system using the Cyclone 360 program, obtaining a set of 1670 186 million points. The registration error was 0.002 m, according to the device specifications, and a 187 density of 1 point every 0.75 mm was achieved. This point model allows analysing the anomalies of 188 the elements that make up the structure in great detail. We work directly from the point cloud, tracing 189 sections which are then used in a CAD program to take measurements of the various elements of the 190 cloister. In this way, the study of the section has been carried out from the exhaustive sectioning of 191 the transverse arches and the arches that open the gallery towards the interior of the cloister, located 192 just above the double circular opening and the twin columns. It has been possible to identify the 193 differences in height between arches, and also to analyse the plotting system, from the two- 194 dimensional sections. The development in height of the vaults of the cloister reveals the difference in 195 height between the different sections that make up the cloister. 196 These measurement points have been identified because they are unambiguous and allow us to 197 accurately characterise the magnitude in both height and planimetry for each bay, in order to analyse 198 its variability relative to the entire structure. 199
7 Nomenclature is also set to differentiate between the four galleries that make up the cloister, and the 200 28 bays that they are divided. 201 As previously indicated, the cloister presents various formal anomalies. Thus, in the first instance, its 202 different measures are recorded, with the aim of parameterizing the formal and dimensional 203 alterations, while studying the basic measure that could be used from a statistical treatment. 204 Measurements are taken both in plan and in section. 205 The data obtained are put in relation to historical and archaeological data, and the current layout of 206 the cloister and can make a hypothesis about the basic units used, the theoretical measurements and 207 proportions and eventually the zones where the dimensions had to be changed to fit them to the 208 previous construction and elements. 209 210 4. CLOISTER ANALYSIS 211 212 4.1. Statistical and metric analysis 213 214 A first hypothesis of the units used must be made to carry out the metric analysis and to obtain the 215 geometric relationship. At the time the construction was carried out, both canas/pams Destre and 216 canas/pams Barcelona could have been used. The metric value equivalent to the SI of the cana 217 Barcelona (cB) is well known. It is a unit, subdivided into 8 pams, which would measure 1.555 m, 218 between 1.55 m and 1.56 m according to various authors (Teixido, 2009). On the contrary, there is a 219 great divergence between the various authors on the value assigned to the cana Destre (cD), ranging 220 from 2.79 m (Alsina & Feliu, 1990) to 2.88 m (Riu, 1990). This last author proposed an average value 221 of 2.82 m which according to him minimises the possible error that this uncertainty generates (Riu, 222 1993). The cana Destre is subdivided into 12 pams. 223 Therefore, if we have considered the value of 1 cana Destre as 2.796 m, and that of 1 cana Barcelona 224 as 1.560 m, and 1 pam Destre (pD) is 1/12 of 1 Destre cana it would be 0.233 m and 1 pam Barcelona 225 (pB) is 0.195 m since it is 1/8 of 1 cana Barcelona. 226 The outer perimeter of the cloister gallery is 186.72 m, divided into 28 bays (32 spaces). If they were 227 homogeneous they would have a length (understood as the measure of the bay in the ground plan, 228 parallel to the gallery) of 5.84 m, which is approximately 25 pams Destre or 30 pams Barcelona. A 229 visual analysis shows clearly that this relationship is not fulfilled in all cases, requiring a more detailed 230 analysis. 231 In the dimensional study of the bays, we have registered the main dimensions in ground plan, length 232 (measure parallel to the gallery) and width (measure perpendicular to the gallery) (Table 1). Since it 233 is difficult to know what was the origin of the measure in its construction phase, measurements have 234 been made both from outside and inside of the wall of the cloister gallery. The thickness of this wall 235 is regular in all the galleries with values in a range between 73 and 76 cm, therefore we neglect its 236 influence in the statistical analysis, however we consider it in the analysis of the construction base 237 modulus. Therefore, in order to simplify the data in the tables we only show the outside 238 measurements. Together with the values in the ground plan, we have studied the dimensions in height 239 of each bay through the different measures of arches and ribs. 240 Visually, the lack of homogeneity in the measures of the vaults can be appreciated on the ground 241 plan, especially in those located in the corners, The results are shown both for each of the galleries 242 and for all the bays considered together. 243 Taking into account the large number of measurements obtained, the results of the analysis are 244 summarised from two parameters, the arithmetic mean and the standard deviation. Both were 245 calculated analysing the existence of outliers regarding a normal distribution. We fixed a reliability 246 of 95%, therefore the measurements that exceed the threshold of 2σ, either in length or width, were 247
8 discarded. Once the values have been discarded, the average and the standard deviation have been 248 recalculated in an iterative process, until all the residuals have a value below the established threshold. 249 In this way, the length measurements corresponding to bays 1, 2, 8, 15, 21, 22, 23, 24 and 28 (Figure 250 2) have been considered outliers. 251 Table 1 shows the result of the arithmetic mean and the standard deviation for each of the calculations 252 for the length and width of each of the bays, As expected, the width remains with discrepancies in the 253 centimetre range while the length, conditioned by the pre-existing construction, presents decametric 254 variations, with a maximum of approximately 30 cm between the bays on the east and north sides, 255 both highly conditioned by the previous construction. 256 The mean length corresponds to 5.96 ± 0.14 m, the interior width 4.97 m ± 0.03 m and finally the 257 exterior width has an average magnitude of 5.71 m with the same deviation as the previous case. 258 Considering the units mentioned above, the conversion has been made to canas Destre (cD) and canas 259 Barcelona (cB). Obtaining that the length would be equivalent to 2.13 canas Destre (2 cD and 1.6 260 pD) with a deviation of 0.05 cD and the width of 2.04 cD (2 cD and 0.5 pD) with a deviation of ±0.01 261 cD. Which would be equivalent to a dimension of 25.6 x 24.5 pD. Considering canas Barcelona, the 262 dimensions would be 3 cB and 6.6 pB x 3 cB and 5.3 pB, with a deviation of ±0.09 and ±0.02 cB 263 respectively, which would correspond to 30.6 x 29.3 pB. 264 265 Table 1. Statistics for bay dimensions regarding the galleries. χ average, σ standard deviation, Units 266 in meters (m), canas Destre (cD), pam Destre (pD), canas Barcelona (cB) and pam Barcelona (pB). 267 268 Since the ratio between the cana Destre and the Barcelona one is approximately 9/5 and 6/5 between 269 pams, and the number of bays is the same in each gallery, the builders are forced to lengthen the bays 270 1-2 pams to fit to the full length of each gallery. 271 272
9 273 Figure 4. Heights assessment. Arches and ribs sections and nomenclature. 274 An equivalent process has been performed for the assessment of measures in height. It is established 275 as a common reference plane, since de cloister ground floor is not flat to allow water evacuation, so 276 the use of a relative measure has been considered more optimal. Thus, working from cross sections, 277 for each arch and rib it is measured the height of the imposts (a, a’), and the rise of inner and outer 278 arches (ab, a’b, aa’b) and ribs (ac, a’c, aa’c) ' (Figure 4). In this way, the height of the arches of each 279 structure is obtained without the alteration produced by the variation of the ground level. 280 The mean value of the height of the arches intersection from the supports is of 3.31 m and a standard 281 deviation of 0.16 m, which is equivalent to 1.18 ± 0.06 canas Destre. All the values for this magnitude 282 and the height of ribs/keystones intersection from the spring are listed in tables 2, 3 and 4. 283 284 Table 2. Summary of results for Inner Arches, χ average, σ standard deviation, Units in metres (m), 285 canas Destre (cD), pam Destre (pD), canas Barcelona (cB) and pam Barcelona (pB). 286 287 288 289 290
16 In an undetermined moment near the turn of the century between twelfth and thirteenth centuries, the 417 project was changed with the construction of the communication door between the Cathedral and the 418 cloister, and the use of a new measuring unit, the cana Destre cD. 419 From the statistical analysis it can be established that there is a higher probability of using the cD, 420 instead of the cB, to constructively define the monumentalization of the cloister. This can be seen, 421 above all, in the width of the gallery, where the bays keep a constant and coherent dimension (about 422 2 cD). On the other hand, its length is slightly longer and more variable. This, surely, is due to the 423 need to readjust the lengths when trying to keep the same number of bays originally intended in a 424 space defined with another metric unit. 425 It is difficult to understand why a new metric unit was introduced during the construction process, 426 and it would be necessary to analyse whether this phenomenon is exclusive to the cloister or whether 427 it also happens in the rest of the Cathedral. The fact that the cana Destre is a specialised unit for 428 measuring buildings and land could be indicative of the presence of professional master builders 429 (Alsina & Feliu, 1990; Riu, 1996). 430 Otherwise, the door is considered to be an element designed for another space that, when it was 431 installed in its current place, distorts the original geometry, since it is located 1.5 m beyond the outer 432 limit of the chevet. This obliges, to avoid breaks in the wall, the construction of a closing wall between 433 this door and the Chapter house, which breaks the axiality of the eastern gallery (Figure 7-D). 434 The flaring of bays 1 and 2, which widen the eastern end of the south gallery, would indicate that this 435 door would have been installed in the middle of the cloister's construction process when, at least, the 436 construction of the south-western corner would have already been completed and, therefore, the 437 western bays of the southern arm would have already been built. 438 Although there are two constructive moments or phases, we are in front of the same urban and 439 propaganda project, which perpetuated the design of the old imperial cult raised during the Flavian 440 dynasty of the s. I AD. The same urban scenery for the justification of the recovery of the political- 441 religious power of the episcopal see. 442 443 ACKNOWLEDGEMENTS 444 This work has been done within the framework of the research project Excavacions en el Conjunt 445 Monumental de la Catedral de Tarragona, III Fase (CLT_2022_EXP_ARQ001SOLC_00000160). 446 447 REFERENCES 448 Alsina, C., & Feliu, G., 1990. Pesos, mides i mesures dels Països Catalans. Curial. 449 Bartoli M. T., 2009. Santa Maria Novella a Firenze, Algoritmi della scolastica per l’architettura, 450 Edifir, Firenze. 451 Boto, G., 2016. Inter primas Hispaniarum urbes, Tarraconensis sedis insignissima: Morphogenesis 452 and Spatial Organization of Tarragona Cathedral (1150-1225), in: G. Boto & J. E. A. Kroesen 453 (Eds.), Romanesque Cathedrals in Mediterranean Europe: Architecture, Ritual and Urban 454 Context, (pp. 85–105). https://doi.org/10.1484/m.ama-eb.5.109567. 455 Buill, F., Núñez-Andrés, M.A., Costa-Jover, A., Moreno, D., Puche, J. M., & Macias, J. M., 2020. 456 Terrestrial laser scanner for the formal assessment of a roman-medieval structure—the cloister 457 of the cathedral of Tarragona (Spain). Geosciences (Switzerland), 10 (11), 1–16. 458 https://doi.org/10.3390/geosciences10110427. 459 Carbonell, E., 2014. Dictamen sobre el claustre de Mas del Vent, Palamós. Generalitat de Catalunya. 460
17 Departament de Cultura. 461 Espejo, P.E.C., 2021. Patrón de medida y proporción como herramientas de análisis histórico y 462 constructivo del patrimonio arquitectónico. Aplicación a varias techumbres de madera del siglo 463 XVI en la Región de Murcia, in: XXVII Jornadas de Patrimonio Cultural Región de Murcia: 5, 464 19, 26 de octubre y 2 de noviembre de 2021 (pp. 213-220). Instituto de Patrimonio Histórico. 465 Figuerola, J., Gavaldà, J. C., Macias, J. M., Menchon, J., Muñoz, A., & Teixell, I., 2007. In Sede, 10 466 anys del Pla Director de Restauració, Tarragona. Arola Editors. Arquebisbat de Tarragona. 467 Giannetti, S., 2013. Analisi sistèmica di un processo creativo medievale. Il duomo di Sansapulcro e 468 San Francesco ad Arezzo. Tesis Doctoral. Università degli Studi di Firenze- Dipartimento di 469 Architettura: Disegno, Storio, Progetto. Florencia. 470 Güell, M., & Grau, J., 2001. La crònica negra de la destrucció d’arxius a la demarcació de Tarragona, 471 Lligall. Revista Catalana d’Arxivística, 31, 65–120. 472 Jiménez, A., 2015. La metrologia històrica como herramienta para la Arqueología de la Arquitectura. 473 La experiència en los Reales Alcázares de Sevilla. Arqueología de la Arquitectura 11. 474 http://dx.doi.org/10.3989/arq.arqt.2015.001. 475 .Macias, J. M., Menchon, J., Muñoz, A., & Teixell, I. (2007). De seu del Concili Provincial a Seu 476 Metropolitana. Treballs arqueològics a la Catedral de Tarragona (2000-2003). Arqueologia 477 Medieval: Revista Catalana d’arqueologia Medieval, 03, 8–29. 478 Macias, J. M., Muñoz, A., Peña, A., Ramon, M., & Teixell, I. (2012). Praesidvum, Templvm et 479 Ecclesia. Les intervencions arqueològiques a la Catedral de Tarragona (2010-2011). Memòria 480 d’una exposició temporal. 481 Mannoni, T. y Milanese, M., 1988. Mensiocronologia, in: R. Francovich y R. Parenti Archeologia E 482 Restauro Dei Monumenti. I Ciclo Di Lezioni Sulla Ricerca Applicata in Archeologia (Certosa 483 Di Pontignano 1987), pp. 383–402. Firenze: All’Insegna del Giglio. 484 Moyano, J. J., Barrera, J. A., Nieto, J. E., Marín, D., & Antón, D., 2017. A geometrical similarity 485 pattern as an experimental model for shapes in architectural heritage: A case study of the base 486 of the pillars in the Cathedral of Seville and the church of Santiago in Jerez, Spain. The 487 International Archives of the Photogrammetry, Remote Sensing and Spatial Information 488 Sciences, 42, 511-517. 489 Riu, M., 1990. Reflexions sobre el destre, la cana de destre i l’agrimensor Jaume de Sanctacília. 490 Medievalia, 9, 191–202. 491 Riu, M., 1996. Pesos, mides i mesures a la Catalunya del segle XIII. Aportació al seu estudi. Anuario 492 de Estudios Medievales, 26 (2), 825–838. 493 Riu, M., 1993. Problemas de metrología aplicados a la estructuración del suelo. Medidas lineales y 494 de superficie. IV Congreso de Arqueología Medieval Española. Sociedades En Transición 495 (Alacant), Vol. 2, 289–294. 496 Roldán, F. J. Reinoso, J. F. Gomez-Blanco, A. J., 2020. Recording and anthropometric 497 parameterization of the architectural heritage: Corral de Carbon, Granada. Informes de la 498 construcción 72 (558). 499 Serrano, M., 2018. Tarragona y la romanidad de su comunidad catedralicia en la Edad Media, in: L. 500 Arcieniega & A. Serra (Eds.), Recepción, imagen y memoria del arte del pasado. (Quaderns A, 501
18 Vol. 7, pp. 71–100). 502 Teixidó, F., 2009. Pesos, mides i mesures al principat de Catalunya i comtats de Rosselló i Cerdanya 503 a finals del segle XVI (1587-1594). Estudis, 49. Fundació Noguera. 504 Willis, R., 1842. On the construction of the vaults of the middle ages (Longman (ed.); Royal Inst). 505 506 507