1 Discharge coefficients to be used in inlet hydraulics Manuel Gómez1, 1 Research Group FLUMEN, Department of Civil and Environmental Engineering (DECA), Technical University of Catalonia, UPC – BarcelonaTech., Barcelona, 08034, Spain Jackson Tellez-Alvarez1, 2,*, 1 Research Group FLUMEN, Department of Civil and Environmental Engineering (DECA), Technical University of Catalonia, UPC – BarcelonaTech., Barcelona, 08034, Spain 2 Consorci Besòs Tordera—CCB Serveis Mediambientals, SAU; 08403 Granollers, Spain Beniamino Russo3, 1 Research Group FLUMEN, Department of Civil and Environmental Engineering (DECA), Technical University of Catalonia, UPC – BarcelonaTech., Barcelona, 08034, Spain *Correspondence to: Jackson Tellez-Alvarez (
[email protected];
[email protected]) Abstract Urban pluvial floods can be produced or exacerbated by insufficient inlets density or by their poor hydraulic efficiency. A proper regard on inlet hydraulic performance is essential to guarantee the correct functioning of urban drainage systems during heavy storm events. The recent advances in computation analysis in the field of hydrodynamics modelling allow to use the well-known concept of dual drainage for design and planning purposes simulating flow transfers between surface layer (street) and underground layer (sewer) through a proper hydraulic characterization of inlet efficiency. Currently, powerful commercial software packages allow the simulation of flow transferring including different approaches and formulas. Many of these approaches include the possibility to treat sewer inlets as an orifice. In this context, this paper presents a methodology to obtain orifice discharge coefficients for three inlets previously tested at the Hydraulic Laboratory of the Technical University of Catalonia. Obtained results show discharge coefficient values between 0,18 and 0,58 with a Froude number between 1.12 and 4.4, quite far from usual recommended values. The procedure can be applied even to non-tested grates. Keyword chosen form ICE Publishing list Drainage & irrigation, Hydraulic & hydrodynamics, Hydrology & water resources. List of notations Qi is the flow intercepted by the inlet (m3/s) Aholes is the area of holes of the grate (m2) Auto-generated PDF by ReView Water Management (Proceedings of the ICE) GomezTellezRussoICEFVWIT HOUTCHANGES.docxMainDocumentRVT Review Copy Only 3
2 H is the specific energy of the flow immediately upstream the inlet (m) including water depth and velocity head, g is the gravity acceleration (m/s2). Cd is the discharge coefficient of the inlet (dimensionless). Q is the flow intercepted by the inlet (m3/s) E is the hydraulic efficiency of the grate inlet y the water depth of this flow in m. A, B are two parameters specific of each inlet, depending on inlet dimensions, area of holes, shape of the bars, etc. Ag is the area of the smallest rectangle having sides parallel/orthogonal to the kerb and containing all the voids of the grate (including bars area) (m2). p is the ratio between the area of holes (Aholes) and Ag (in %). nt is the number of transversal bars. nl is the number of longitudinal bars. nd is the number of diagonal bars. L is the length of the inlet (cm). W is the width of the inlet (cm). Fr is the Froude number of the approaching flow. V is the cross-section velocity (m/s) S is the cross-section area associated to the flow (m2) W is the top width of the approaching flow (m) g is the gravity acceleration (9.81 m/s2) Auto-generated PDF by ReView Water Management (Proceedings of the ICE) GomezTellezRussoICEFVWIT HOUTCHANGES.docxMainDocumentRVT Review Copy Only 4
3 1 Introduction Pluvial urban flooding in urban and peri-urban catchments is one of the main concerns for local authorities. Many times, these problems can be produced or exacerbated by insufficient inlets density or by their poor hydraulic efficiency (Russo et al., 2021; Ortiz et al., 2021). In this context, the old vision that drainage systems are composed exclusively by the sewer network of the underground conduits is now updated, including, in the drainage concept, the consideration of the overland flow going along the street network, and keeping in mind the interest of a good performance of the surface drainage systems composed by a set of inlets ensuring water levels and velocities that do not put in hazard conditions pedestrians and vehicles (Russo et al, 2013; Martínez-Gomariz et al, 2016, 2017, 2018; Hamid Hussein Al-Qadami et al. 2021; Gissing et al., 2019). In this framework, grate inlets play a key role in the performance of the drainage systems for their basic function of intercept stormwater runoff and quickly introduce it into underground conduits avoiding unwanted hazard conditions and ensuring the normal development of urban activities (Russo et al. 2013, 2015, 2020; Cea and Costabile, 2022). An equilibrium between surface and underground flow must be achieved in such a way conduit work close to their maximum capacity because the surface flow was intercepted and introduced into the sewer networks at the right places. It means that the number of inlets is enough and that hydraulics of these elements is correct. Due to the geometrical complexity of the linking structures, inlets are usually represented by weir or orifice equations within most urban flood coupled 1D/2D models (Djordjevic et al., 2005; Leandro et al., 2009; Martins et al., 2017, Gómez et al. 2016). However, a robust calibration and validation of the coefficients involved in the hydraulic description of those equations is not found elsewhere, even not provided by the manufacturers. Moreover, in the user’s manual of most of commercial software there is no indication on which values should be used. In this dual drainage approach, the link between upper and lower drainage layers are the inlets placed in the surface of the city. So, in any numerical analysis it is extremely relevant to use a proper approach to calculate the inflow from the surface to the sewer (Russo et al., 2015). This gives a dual result, the correct amount of water not intercepted by the inlets and that could produce a risk for surface activities, and the real amount of water intercepted and introduced to the sewer network. A proper quantification of these two flows is the key point to perform a good Auto-generated PDF by ReView Water Management (Proceedings of the ICE) GomezTellezRussoICEFVWIT HOUTCHANGES.docxMainDocumentRVT Review Copy Only 5
4 dual drainage analysis. With this aim, a proper assessment of the flow transfers is extremely relevant. The hydraulics of a single inlet must be characterized with real experimental values and not considering parameters extracted from other hydraulic examples. Recently, Rubinato et al. (2017) experimentally validated the behavior of weir/orifice equations to describe the flow exchange through a scaled open manhole with circular shape. This study does not consider traditional inlets, whose shape is generally rectangular and with smaller dimensions than manholes. Discharge coefficients were calibrated from a dataset found in a lab installation at the University of Sheffield. Previous studies of hydraulic characterization of inlets include the activities by Argue (1986), Spaliviero and May, (1998) and Gómez and Russo (2011). But unfortunately, those datasets have been used few times in further studies, mainly due to difficulties to adapt the procedures to estimate inlet efficiency to the numerical codes generally used by practitioners and technicians working in this field that consider the concept of discharge coefficients for the hydraulic characterization of these elements. Commercial and public domain software generally includes orifice type equations to characterize the inlet hydraulics, but it is not easy to find the real discharge coefficients because the suppliers and manufacturers of inlets do not provide this information. Moreover, some of the procedures proposed like the UPC method can be modified in such a way to provide discharge coefficients to the users, for tested or non-tested grates. In order to facilitate the use of this approach and cover this gap, this paper aims to propose a methodology to achieve the correct discharge coefficients depending on flow and street geometric conditions and the type of grate inlets. Recently, Cosco et al. (2020) Xia et. al. (2022) and Cardenas et al., (2023) proposed some methods to estimate discharge coefficients (considering orifice and weir approaches) of grate inlets through experimental test. In both cases, approximations are based on approaching velocity and Froude number. In this context this work provides a general methodology to achieve discharge coefficients for any type of inlets (including non-tested grates) for the characterization of their hydraulic efficiency. This result could help technicians and researchers to achieve a scientific-based link between 2D surface and 1D sewer models achieving a proper inlet hydraulics characterization. Auto-generated PDF by ReView Water Management (Proceedings of the ICE) GomezTellezRussoICEFVWIT HOUTCHANGES.docxMainDocumentRVT Review Copy Only 6
5 2 Theoretical background of inlet hydraulics 2.1 Inlet hydraulics review Inlet hydraulic efficiency can be expressed as the ratio between intercepted (Qi) and approaching flow (Q): 𝐸=𝑄𝑖 𝑄 (1) One of the options included in most commercial codes, public domain or licensed, to characterize inlet hydraulic efficiency, is the orifice or weir methodology to approach the intercepted flow by one single inlet. These are well established procedures in hydraulics, and in case of orifice, the following equation is by many computer codes: 𝑄𝑖=𝐶𝑑𝐴ℎ𝑜𝑙𝑒𝑠√2𝑔𝐻 (2) Where Cd is the orifice discharge coefficient, Aholes is the void area of the grate, g is the gravity acceleration and H is the specific energy flow. Based on the results obtained by Cosco et al. (2020) and Gomez and Russo (2011), the purpose of this paper is to propose discharge coefficients to be used in this type of orifice equation normally adopted by commercial hydrodynamics code to estimate inlet hydraulic efficiency satisfactorily. Among the different parameters to be considered, the area of holes is easily found in case of fully submerged inlets (normal situation in case of heavy rainfall events and significant gutter flow) and coincide to those provided by the manufacturers through their commercial catalogues. Specific energy upstream of the grate E depends of the approaching flow. It is an energy head relative to the channel bottom and include the water depth and the velocity head (Cosco et al., 2020), while Cd represents the characteristics and the goodness of the hydraulic design of the inlet in terms of the better or worse design of the inlet geometry to intercept more water from the streets. But one of the problems is that manufacturers do not provide this value and the users must “estimate” the discharge coefficients. Few studies on inlets or bottom racks can be found in the literature although some references are well known (Ranga Raju, 1993; Mostkow, 1957; Noseda, 1956; Subramanya & Sengupta, 1981). In the cited work, Rubinato et al. (2018) showed that discharge coefficients varied from 0.115 to 0.372 for the weir equation, and from 0.349 to 2.038 for the orifice approach. Auto-generated PDF by ReView Water Management (Proceedings of the ICE) GomezTellezRussoICEFVWIT HOUTCHANGES.docxMainDocumentRVT Review Copy Only 7
6 So, practitioners need to provide discharge coefficients to be used by the computer code and, due to the lack of specific references, in many cases they apply a value of Cd=0,6, value usually found in technical manuals (Neenah Foundry Company (NFCO), 2021) or for orifice discharges from a tank in case of orifices located on vertical walls. Notwithstanding the type of flow associated to the intercepted discharge by an inlet is quite different and maybe the “traditional” value Cd=0,6 commonly used and suggested could not describe properly this flow conditions. It can be argued that when flow is intercepted in the surface level immediately turns 90º and drops through the inlet, something far from the condition of the outlet in a tank. In this context, it would be good to check if the real Cd values are close to 0,6 or not. Moreover, it could be interesting for practitioners to express the flow intercepted in an orifice equation and provide the discharge coefficients to be applied for different flow conditions. That makes easy for instance to use some commercial software including the orifice formulation, just using the right discharge coefficients. 2.2 UPC method The UPC method was presented by Gómez and Russo (2011) with a proposal of a potential law relating the dimensionless value of inlet efficiency (E), to flow parameters (approaching flow Q and upstream water depth y) and two grate geometric coefficients (A and B) as follow: 𝐸=𝐴(𝑄 𝑦)−𝐵 (3) These two parameters (A and B) can be better estimated through hydraulic tests as shown by the authors using a physical model representing a road lane at the UPC laboratory where it was possible to test inlets in real scale with flows up to 200 l/s. In the case of not having the possibility to perform laboratory tests, A and B could be properly estimated by some geometric characteristics too. In fact, experimental results linked inlet efficiency to some geometric parameters of the grate (such as area of holes, number and type of the bars, etc.) through the two parameters A and B: 𝐴= 1.988 𝐴𝑔 0.403 𝑝0.190(𝑛𝑡+1)0.088(𝑛𝑙+1)0.012(𝑛𝑑+1)0.082 (4) Auto-generated PDF by ReView Water Management (Proceedings of the ICE) GomezTellezRussoICEFVWIT HOUTCHANGES.docxMainDocumentRVT Review Copy Only 8
7 𝐵=1.346 𝐿0.179 𝑊0.394 (5) where Ag is the area of the smallest rectangle having sides parallel to the curb containing all the void of the grate (including bars area) (in m2), p is the ratio between the void area (AH) and (Ag) (in %), nt, nl and nd are, respectively, the number of transversal, diagonal and longitudinal bars, L is the length of the inlet (cm) and W is its width. Intercepted flows values can be achieved by a table relating these values to different approaching flows, calculated with Eq. 3. This is for instance the way HEC-HMS (Hydrologic Engineering Center, 2021) uses to assess the flow intercepted by a single inlet with the element DIVERSION. In this case this table must be defined by the user. In a similar way, new version SWMM 5 (United States Environmental Protection Agency, 2022) suggest to use an inflow/diversion table as in HMS. Nothwithstanding the previous examples, a large set of commercial softwares include by default other procedures to calculate flow diversions, and the orifice option is one of the most used, included in SWMM 5 (United States Environmental Protection Agency, 2012) and, InfoWorks ICM (Innovyze Company (2021). Computer code calculates specific energy, and inlet area of holes is generally provided by the user. The other value that needs to be given by the user is the discharge coefficient. In this framework, is it possible to provide this value instead to give just the A and B parameters? This is the purpose of this paper and the proposed procedure is outlined below. 3. Methodology 3.1 Experimental set-up This section presents the experimental set-up used for the test protocol. The tests were developed in the hydraulic laboratory of the Technical University of Catalonia in Barcelona, Spain (Figure 1). The experimental campaign studied the hydraulics efficiency of grate inlets. The platform for grate inlet tests is a model of real-scale that represents an urban street lane with 3 meters width and 5.5 meters long. The maximum approaching flow on the platform is 250 l/s. The hydraulic scheme in the lab for the approaching flow includes a pump, systems of water distribution in the lab and a large water reservoir underground with 1000 m3 total volume. The Auto-generated PDF by ReView Water Management (Proceedings of the ICE) GomezTellezRussoICEFVWIT HOUTCHANGES.docxMainDocumentRVT Review Copy Only 9
8 platform slope can be changed in longitudinal direction from 0 to 10% with an electric engine, and in transversal direction from 0 to 4% by hand. In addition, upstream the platform was located a reservoir to dissipate the velocity head of the incoming flow and distribute the flow in the wide of the platform according to the geometry of the street. Test protocols and facilities were the same used in previous experiences. More details are presented in Gómez and Russo (2011) and Tellez- Alvarez et al. (2020). Figure 1: Experimental facility. 3.2 Tested grates Laboratory test developed from 2010 to 2020 (Gomez & Russo, 2011; Russo, et. al, 2013, Tellez- Alvarez, et. al. 2020a; Tellez-Alvarez et. al, 2020b, Tellez-Alvarez et. al, 2020c, Tellez-Alvarez et. al, 2021, Russo, et. al, 2022), include three different types of grate inlets, among the most used in the city of Barcelona. Typical values for inlet dimensions are around 70 to 80 cm long, and 30 cm width (Figure 2). The models are called Barcelona1, E-25 and Meridiana. Figure 2: Grate Inlets considered in the analysis: Barcelona1, E25 and Meridiana. Dimensions of the inlets considered are indicated in the Table 1 with the corresponding values of length, width and φ, the ratio between void area and total area of the inlet. Table 1 Data of the grate inlets studied. For the experimental campaign 6 different geometric configurations of the platform were considered (longitudinal slope of 1, 2, 4, 6, 8, 10% with a fixed transversal slope of 2%) while the range of flow was between 25 and 200 l/s. Maximum tested flow was 200 l/s. 3.3 Proposed procedure The idea to obtain the discharge coefficient by experimental tests on grate inlets is quite simple. For different approaching flows along the platform, the intercepted flow was measured by a vnotch weir, while the hydraulic parameters of the circulating flow were measured water depth and calculates (mean flow velocity upstream the inlet). Knowing inlet geometry (and in particular its Auto-generated PDF by ReView Water Management (Proceedings of the ICE) GomezTellezRussoICEFVWIT HOUTCHANGES.docxMainDocumentRVT Review Copy Only 10
9 void area Aholes), the expression of orifice discharge described in the Eq. 2 can be used to obtain the discharge coefficient value for every flow, every geometry tested and each grate. It should be stated that although not always the inlet is fully covered by water, the whole area of holes was considered in Eq. 2, so always the same values were considered during the tests for each grate. Specially for high flows, the grates are fully covered by water, and only for low flows part of the inlet cannot be completely covered by water. It is clear that, from the flood management point of view, the last conditions are less interesting and less frequent in case of heavy storm events. The process was repeated for different slopes of the street too, producing different depths and velocities, and associated Froude numbers. In this analysis a fixed transverse slope equal to 2% was considered. Furthermore, the analysis was performed for a maximum water level up to 0.15 m (typical curb height in Barcelona) considering a triangular cross-section (uniform triangular gutter), and longitudinal slopes of 1%, 2%, 4%, 6%, 8% and 10%. In all the cases, 1D approach was assumed for the estimation of the flow and the discharge coefficient, although the reality of the phenomena can be described more in detail by a 3D process (Cosco et al., 2020). Relations between discharge coefficients versus Froude number are proposed for the three types of grates inlets studied as Barcelona1, E-25 and Meridiana. The Froude number was estimated according the equation (6): 𝐹𝑟=𝑉 √𝑔𝑆 𝑊 (6) Table 2 Geometric data of the grate inlets studied. On the other hand, the parameters consider in this procedure were the area of holes (Aholes) and the A and B coefficients specific for each grate (Table 2). A and B parameters were estimated according the UPC Method developed in the mentioned in 2.1 (Gómez and Russo, 2011). 4. Results Auto-generated PDF by ReView Water Management (Proceedings of the ICE) GomezTellezRussoICEFVWIT HOUTCHANGES.docxMainDocumentRVT Review Copy Only 11
16 Kemper, S.; Schlenkhoff, A. Experimental study on the hydraulic capacity of grate inlets with supercritical surface flow conditions.Water Sci. Technol. 2019, 79, 1717–1726. Kitsikoudis, V., Erpicum, S., Rubinato, M, Shucksmith, J. D., Archambeau, P., Pirotton, M., Dewals, B. (2021). Exchange between drainage systems and surface flows during urban flooding: Quasi-steady and dynamic modelling in unsteady flow conditions, Journal of hydrology, 602, 126628. Doi: 10.1016/j.jhydrol.2021.126628 Hydrologic Engineering Center (2021). Hydrologic Modeling Systems (HEC-HMS). HECHMS User’s Manual, version 4.9. Leandro, J.; Chen, A.; Djordjević, S. and Savić, D (2009). Comparison of 1D/1D and 1D/2D coupled (sewer/surface) hydraulic models for urban flood simulation. J. Hydraul. Eng., 135, pp. 495-504, 10.1061/(ASCE)HY.1943-7900.0000037. Martins, R.; Leandro, J.; Chen, A.; Djordjević, S. (2017). A comparison of three dual drainage models: shallow water vs local inertial vs diffusive wave. Journal of Hydroinformatics, 19(3), 331-348. Doi: 10.2166/hydro.2017.075. Mostkow, MA. (1957) A theoretical study of bottom type water intakes. La Houille Blanche 12(4): 570–580. Noseda, G. Correnti permanenti con portata progressivamente decrescente, defluenti su griglie di fondo. L’Energia Elettrica 1956, 565–581. Neenah Foundry Company (NFCO). Inlet Spacing Calculators, Website Applications; Neenah Foundry Company (NFCO): Neenah, WI, USA, 2021. Ranga Raju, K.G. (1993) Flow through open-channels. Tata McGraw-Hill. New Delhi. Rubinato, M, Martins, R., Kesserwani, G., Leandro, J., Djordjevic, Schucksmith, J. (2017). Experimental calibration and validation of sewer/surface flow exchange equations in steady and unsteady flow conditions. Journal of Hydrology, 552, 421-432. Doi: 10.1016/j.jhydrol.2017.06.024. Russo, B.; Valentín, M.G.; Tellez-Alvarez, J. (2021). The Relevance of Grated Inlets within Surface Drainage Systems in the Field of Urban Flood Resilience. A Review of Several Experimental and Numerical Simulation Approaches. Sustainability, 13, 7189. Doi: 10.3390/su13137189. Auto-generated PDF by ReView Water Management (Proceedings of the ICE) GomezTellezRussoICEFVWIT HOUTCHANGES.docxMainDocumentRVT Review Copy Only 18
17 Russo, B.; Velasco, M.; Locatelli, L.; Sunyer, D.; Yubero, D.; Monjo, R.; Martínez- Gomariz, E.; Forero-Ortiz, E.; Sánchez-Muñoz, D.; Evans, B.; Gómez, A.G. (2020) Assessment of Urban Flood Resilience in Barcelona for Current and Future Scenarios. The RESCCUE Project. Sustainability, 12, 5638. Doi: 10.3390/su12145638. Russo, B., Gómez, M. & Macchione, F. Pedestrian hazard criteria for flooded urban areas. Nat Hazards 69, 251–265 (2013). Doi: 10.1007/s11069-013-0702-2. Russo, B., Gómez, M, Tellez, J. (2013). Methodology to Estimate the Hydraulic Efficiency of Nontested Continuous Transverse Grates. Journal of Irrigation and Drainage Engineering (ASCE), 864-871, 139(10). Doi: 10.1061/(ASCE)IR.1943-4774.0000625. Russo, B., Sunyer, D., Velasco, M., Djordjević, S (2015). Analysis of extreme flooding events through a calibrated 1D/2D coupled model: the case of Barcelona (Spain). Journal of Hydroinformatics, 17 (3): 473–491. Doi: 10.2166/hydro.2014.063. Sanz-Ramos, M., Tellez Alvarez, J.D., Bladé, E., Gómez-Valentín, M. (2020). Simulating the Hydrodynamics of Sewer-Inlets Using a 2D-SWE Based Model. In: Gourbesville, P., Caignaert, G. (eds) Advances in Hydroinformatics. Springer Water. Springer, Singapore. Doi: /10.1007/978-981-15-5436-0_64. Spaliviero, F. and May, RWP. (1998) Spacing of Road Gullies. Hydraulic Performance of BS EN 124 Gully Gratings. HR Wallingford, UK, internal report. Subramanya, K. and Sengupta, D. (1981) Flow through bottom racks. Indian Journal of Technology. 19(2). 64–67. Tellez-Alvarez, J.; Gómez, M.; Russo, B.; Amezaga-Kutija, M. (2021). Numerical and Experimental Approaches to Estimate Discharge Coefficients and Energy Loss Coefficients in Pressurized Grated Inlets. Hydrology 2021, 8, 162. Doi: 10.3390/hydrology8040162. Tellez-Alvarez, J.; Gómez, M.; Russo, B. (2020a). Quantification of Energy Loss in Two Grated Inlets under Pressure. Water, 12, 1601. Doi: /10.3390/w12061601. Tellez Alvarez, J.D., Gómez, M., Russo, B. (2020b). Modelling of Surcharge Flow Through Grated Inlet. In: Gourbesville, P., Caignaert, G. (eds) Advances in Hydroinformatics. Springer Water. Springer, Singapore. Auto-generated PDF by ReView Water Management (Proceedings of the ICE) GomezTellezRussoICEFVWIT HOUTCHANGES.docxMainDocumentRVT Review Copy Only 19
18 Doi: /10.1007/978-981-15-5436-0_65. Tellez-Alvarez, J., Gómez, M., Russo, B. and Redondo, J.M. (2020c). Using surface flow image velocimetry to analyse flow approaching grated inlets, Proceedings of the Institution of Civil Engineers - Water Management 2020 173:3, 152-162. Doi: 10.1680/jwama.18.00103. US Department of Transportation (1996) Urban Drainage Design Manual. US Department of Transportation, Washington DC, USA, Hydraulic Engineering Circular No. 22. United States Environmental Protection Agency (2022). Storm Water management Model (SWMM) version 5.1 User’s Manual. Xia, J., Dong, B., Zhou, M., Ahmadian, R., Falconer. R. A., Li, Q., Zhang, X. (2022). A Unified formula for discharge capacity of street inlets for urban flood management, Journal of Hydrology, 609, 127667. Doi: 10.1016/j.jhydrol.2022.127667. Zhang, H., Wu, W., Hu, C., Hu, C., Li, M., Hao, X., Liu, S. (2021). A distributed hydrodynamic model for urban storm flood risk assessment, Journal of Hydrology, 600, 126513. Doi: 10.1016/j.jhydrol.2021.126513. Auto-generated PDF by ReView Water Management (Proceedings of the ICE) GomezTellezRussoICEFVWIT HOUTCHANGES.docxMainDocumentRVT Review Copy Only 20
Figure1. Experimental facility. Approaching flow Carryover flow Inlet position during the test Auto-generated PDF by ReView Water Management (Proceedings of the ICE) Figure 1.docx F igure RVT Review Copy Only 21
FULL PAPER TEMPLATE - 2020 Figure 2. Grate Inlets considered in the analysis: Barcelona1, E25 and Meridiana. Barcelona1 E-25 Meridiana Auto-generated PDF by ReView Water Management (Proceedings of the ICE) Figure 2.docx F igure RVT Review Copy Only 22
FULL PAPER TEMPLATE - 2020 Figure 3. Discharge coefficient for grate Barcelona1 vs. Approaching flow. 0,00 0,10 0,20 0,30 0,40 0,50 0,60 0,70 0,00 0,20 0,40 0,60 0,80 1,00 Cd Approaching flow (m3/s) Barcelona1 Longitudinal slope 1% Longitudinal slope 2% Longitudinal slope 4% Longitudinal slope 6% Longitudinal slope 8% Longitudinal slope 10% Auto-generated PDF by ReView Water Management (Proceedings of the ICE) Figure 3.docx F igure RVT Review Copy Only 23
Figure 4. Discharge coefficient for grate E-25 vs. Approaching flow. 0,00 0,10 0,20 0,30 0,40 0,50 0,60 0,70 0,00 0,20 0,40 0,60 0,80 1,00 Cd Approaching flow (m3/s) E-25 Longitudinal slope 1% Longitudinal slope 2% Longitudinal slope 4% Longitudinal slope 6% Longitudinal slope 8% Longitudinal slope 10% Auto-generated PDF by ReView Water Management (Proceedings of the ICE) Figure 4.docx F igure RVT Review Copy Only 24
Figure 5. Discharge coefficient for grate Meridiana vs. Approaching flow. 0,00 0,10 0,20 0,30 0,40 0,50 0,60 0,70 0,00 0,20 0,40 0,60 0,80 1,00 Cd Approaching flow (m3/s) Meridiana Longitudinal slope 1% Longitudinal slope 2% Longitudinal slope 4% Longitudinal slope 6% Longitudinal slope 8% Longitudinal slope 10% Auto-generated PDF by ReView Water Management (Proceedings of the ICE) Figure 5.docx F igure RVT Review Copy Only 25
FULL PAPER TEMPLATE - 2020 Figure 6. Discharge coefficient for grate Barcelona1 vs. Froude number. 0,00 0,10 0,20 0,30 0,40 0,50 0,60 0,70 0,00 0,50 1,00 1,50 2,00 2,50 3,00 3,50 4,00 4,50 5,00 Cd Fr Barcelona1 Approaching flow 10 l/s Approaching flow = 25 l/s Approaching flow = 50 l/s Approaching flow = 75 l/s Approaching flow = 100 l/s Approaching flow = 125 l/s Approaching flow = 150 l/s Approaching flow = 200 l/s Approaching flow = 250 l/s Approaching flow = 300 l/s Approaching flow = 400 l/s Approaching flow = 500 l/s Approaching flow = 750 l/s Approaching flow = 1000 l/s Auto-generated PDF by ReView Water Management (Proceedings of the ICE) Figure 6.docx F igure RVT Review Copy Only 26
Figure 7. Discharge coefficient for grate E-25 vs. Froude number. 0,00 0,10 0,20 0,30 0,40 0,50 0,60 0,70 0,00 0,50 1,00 1,50 2,00 2,50 3,00 3,50 4,00 4,50 5,00 Cd Fr E-25 Approaching flow 10 l/s Approaching flow 25 l/s Approaching flow 50 l/s Approaching flow 75 l/s Approaching flow 100 l/s Approaching flow 125 l/s Approaching flow 150 l/s Approaching flow 200 l/s Approaching flow 250 l/s Approaching flow 300 l/s Approaching flow 400 l/s Approaching flow 500 l/s Approaching flow 750 l/s Approaching flow 1000 l/s Auto-generated PDF by ReView Water Management (Proceedings of the ICE) Figure 7.docx F igure RVT Review Copy Only 27