Full text
Bending behaviour of sandwich panels of vegetal fabric reinforced cementitious 1 matrix: experimental test and numerical simulation 2 Luis Mercedes (1), Ernest Bernat-Maso (1)(3), Borja Martínez (1) 3 (1) Department of Strength of Materials, Polytechnic University of Catalonia, Terrassa, Spain 4 (2) LITEM Laboratory for Technological Innovation of Structures and Materials, Spain 5 (3) Serra Húnter Fellow 6 Abstract 7 Sandwich panels represent a lightweight solution with additional properties as insulation 8 compared to traditional solutions used for building enclosures. In this study, a technology 9 based on vegetal FRCM (fabric reinforced cementitious matrix) provides an economical, 10 sustainable and competitive solution. The research introduces a composite design made 11 of different vegetal fabrics (hemp and sisal) and mortar as skins of the sandwich and a 12 core of extruded polystyrene. Both composite skins were connected with different types 13 of connectors including vegetal designs. An experimental campaign of sandwich panels 14 included four-point bending tests and a later development of numerical models capable 15 of reproducing the experimental results. The results obtained show that the use of vegetal 16 fabrics and connectors were as competitive for the development of effective composite 17 action as synthetic fabrics (glass fiber). 18 19 Keywords: Sandwich panels, FRCM, Cementitious matrix, Vegetal fibres, Bending test, 20 Numerical model 21 1 Introduction 22 Sandwich panels consist of cores of an insulating material commonly covered by layers 23 of concrete. These types of panels can be structural and non-structural. In structural 24 panels, the concrete layers are commonly reinforced with steel bars that allow better 25 efficiency against tensile and shear stresses, in the case of panels without structural 26 function, a steel mesh reinforcement is also necessary to withstand the stresses caused by 27 temperature-induced contraction. Also shear connectors are introduce to improve the 28 composite action and structurally bond concrete skins. 29 Sandwich panels are used as exterior and interior walls on building structures. The 30 insulation is used to reduce the heating and cooling costs for the structure. These were 31 typically used in low-rise industrial buildings, but are increasingly being used in medium 32 and high-rise residential and commercial buildings [1][2]. The application of these for 33 facades of factory and industrial buildings has gained importance in the last years mainly 34 due to prefabrication (Precast Concrete Sandwich Panel: PCSP) [3]. The PCSP system 35 provides a thermally efficient cladding solution [4] and the panels are commonly 36 prefabricated at the factory and therefore should achieve the advantages of higher quality 37 control and lower risk of poor detail, and thus also assume significant savings in the 38 execution of the work. 39 However, traditional PCSPs are heavy and are often preferred for low-rise buildings. To 40 broaden its applicability to a wider range of buildings, it has been necessary to reduce the 41 weight and thickness of the panels, therefore, a series of studies [5][1] have focused on 42 the design of thinner sections. But the reduction in size and weight should not compromise 43 the thermal and structural requirements. 44 In recent years sandwich panels have experienced significant advancements, through the 45 use of new and advanced concretes and insulators, as well as the new technologies used 46 to improve composite action (shear connectors), have led to new lighter and thinner 47 designs. Due to this interest in reducing the total thickness of the sandwich panels, two 48 of the most promising options have been the use of high-performance insulation [6], and 49 the use of FRCM [5][7]. 50
FRCM is a composite material that consists of cementitious matrix (commonly mortar) 51 and fabric reinforcements, which are mainly fabricated synthetic fibres in order to design 52 lightweight structures. 53 In the 7th Framework Programme for Research and Technological Development, the 54 European Commission financed the project EASEE (2012–2016) [8], proposed FRCM 55 sandwich panels to façade solutions for the energy retrofitting of multi-storey multi- 56 owners. The high aesthetic potential, low impact on occupant life during installation, high 57 durability and increase in impact resistance made this solution competitive with the 58 finishing system and exterior insulation. 59 The structural behavior of a sandwich panel depends on their composite action, strength 60 and stiffness that is better developed by the inclusion of shear connectors. In the study 61 presented in [9] it was developed a an insulation layer made of mineral hydrated foamed 62 material (MHFM) and lightweight foamed concrete (LFC), where the results show that 63 the strength of the sandwich panels are enhanced with an increase in the number of shear 64 connectors, and at least 10 shear connectors per 1.8 m2 are required for full-composite 65 action. 66 Other study [10] was conducted to evaluate the strength and response of commercial 67 connectors. Fourteen different shear connectors were tested. The results shown that shear 68 connectors used in sandwich panels construction have significative variation in stiffness, 69 strength and deformability. The connectors exhibited elastic-plastic, plastic-hardening 70 and elastic-brittle responses. 71 However, a study presented by [5] found that the connectors used were causing the initial 72 failure mechanism in the form of localized pull-out within an element. 73 Focusing on the numerical models for sandwich panels, the study presented by [11] 74 develop a numerical model to reproduce the mechanical behavior of sandwich panels. 75 Two types of sandwich panels were developed: a fabric reinforced concrete panel with 76 cellular lightweight concrete insulation and an ultra-high performances concrete panel 77 with aerated autoclaved concrete insulation. The results shown the composite action in a 78 full sandwich panel. Also, the modelling approach was used for the optimization of the 79 panels in terms of identifying the number and location of connectors, minimizing the 80 thickness and evaluating varying anchorage systems. 81 Other simulation study [12] presented a quasi-static finite element analysis conducted on 82 precast lightweight foamed concrete sandwich panel (PLFP). The PLFP subjected to axial 83 load was simulated. The analysis determined vertical and horizontal displacement, 84 ultimate load carrying capacity and damage criteria where the model used for PLFP 85 simulation with imperfection and perfect condition could reproduce their structural 86 behavior accurately. 87 In order to propose sustainable solutions, [13] develop an innovative sandwich panels 88 based on the use of thin layers of Sisal Fibre-Cement Composites. In this were studied 89 long unidirectional aligned sisal fibres (700 mm) and short sisal fibres (50 mm) randomly 90 distributed in the matrix. The panels were subjected to a four-point bending test. The 91 results determined that the long sisal fibres were more effective to provide to the 92 sandwich panel higher flexural capacity than when using short sisal fibres, also, long 93 fibres ensured the development of a deflection hardening behavior followed by the 94 formation of multiple cracks, while short sisal fibres presented a softening response after 95 cracking. 96 Vegetal fibres are characterized by different properties due to nonuniformity of its 97 structure [14], their mechanical, physical and geometric properties are influenced by 98 some factors like: hydrophilic nature, moisture content, defects, structure, cell 99
dimensions, and morphology of the plant. For composites applications, the vegetal fibres 100 mostly analyzed and studied are the bast fibres (jute, flax and hemp) and leaf fibers (sisal). 101 The organic origin of vegetal fibres favours their degradation in the environment of 102 cementitious matrix composites [15] owing to high alkalinity and wet-dry cycles[16]. 103 Some authors have studied the feasibility of coating of fibres with a resin [17] to avoid 104 the degradation of the fibres. The coating on commercial meshes to use in FRCM 105 composites is a widely used technique. In some cases, this avoids the fibre degradation 106 within the cementitious matrix [18], and in other cases, it improves the mechanical 107 properties and the bond of the meshes with the matrix [19][20]. Due to climate change 108 and needs for energy efficient technologies, the challenge of incorporating more 109 sustainable solutions in construction is a must. Several solutions of FRCM have been 110 previously attempted by other researcher using synthetic fabrics. Nevertheless, this study 111 moves in the direction of incorporating novel solutions of vegetal fabrics and connectors 112 to the FRCM composites as skins of sandwich panels. The design and manufacturing of 113 vegetal fabrics coating with epoxy resin included the comparison of hemp and sisal 114 performance and the contrast with a glass fabric solution. Also, connectors compared two 115 vegetal designs with traditional steel bolts. Finally, a numerical model reproduces the 116 experimental observations. 117 118 2 Materials and specimens 119 In order to face the experimental campaign some samples of sandwich panels were 120 produced according next conditions. 121 122 2.1 Mortar 123 For manufacturing the FRCM wythes of the sandwich panels, the commercial mortar 124 (type R3 according with UNE-EN 1504-3 standard [21]) used in other study [22][23] with 125 vegetal fibre was include. This mortar was selected because of the effectiveness 126 interaction with the vegetal fabric (there was not slipping failure) shows in [22]. Table 1 127 present its 28th days mechanical properties. 128 129 Table 1. Mortar properties [17] 130 Chemical composition (1) Prepared cement mortar, improved with synthetic resins and silica fume, and reinforced with polyamide fibres Density of fresh Mortar (1): 2.1 kg/l (a + 20ºC). Granulometry (1): 0–2 mm Compressive Strength (2): 39.25 MPa Flexural Strength (2): 6.56 MPa Tensile Strength (2): 2.9 MPa (1) Supplied by manufacturer; (2) results of test (EN 1015-11: 2000) 131 2.2 Fabrics 132 Two type of vegetal fabrics and another one of synthetic fibres were used to manufacture 133 the FRCM wythes: Hemp, sisal and glass. Glass fibre was chosen as contrast material 134 because its mechanical properties are or similar to hemp fibres. 135 Vegetal fabrics were manufactured with sisal and hemp yarns (both with diameter of 2.5 136 mm). 137
This fibres were selected because hemp and sisal FRCM specimens achieved high tensile 138 strength in a previous study [22]. In such study the fabrics and yarns were coated with 139 epoxy resin to avoid the degradation of the fibres by the aggressive environment of ce- 140 mentitious matrix composites [15] (high alkalinity and humidity cycles). The epoxy resin 141 used to coat the yarns was a low-viscosity and high-adhesion resin. This resin was se- 142 lected based on its good interactions with FRCMs, which were observed in [22]. 143 The geometry of vegetal fabrics was designed by using the commercial glass fibre meshes 144 as a reference (see Figure 1). In the case of vegetal fabrics manufacturing meshes with 145 greater thickness was necessary to reach the load capacities of glass fabrics. It was used 146 two yarns for each tuft. 147 Weft yarns of hemp and sisal fabric were made with other hemp yarns of 0.5 mm, this to 148 reduce the thickness of the weft and wrap crossing point. 149 150 Figure 1. Design of reinforcing Fabrics 151 A rectangular wooden mould was fabricated taking as a reference the mold used as a loom for the 152 manufacturing of the vegetal fabrics in [22]. The mould is 30 cm ×100 cm and has nails at its 153 external boundaries (Figure 2). The nails are arranged at 3 cm increments in the warp direction, 154 and 3 cm increments in the weft direction (see Figure 1). 155 After the fabrics were woven, they were coated with epoxy resin. After one day of curing, the 156 fabrics were cut with dimensions of 25 cm × 95 cm. 157
158 Figure 2. Vegetal fabrics: (a) Hemp and (b) sisal 159 The mechanical properties of fibres and the tuft (two yarns in the vegetal fabrics case) are listed 160 in Table 2 and Table 3. The coated tuft data were obtained experimentally in this study using the 161 tensile test procedure presented in [22]. Also, the properties and manufacturing parameters of 162 fabrics are listed in Table 4. 163 Table 2. Fibres properties [24][25][26] 164 Properties Glass Hemp Sisal Density (g/cm3) 2.55 1.48 1.45 Tensile strength (MPa) 2400 550-900 511-635 Young modulus (GPa) 73 70 9.4-22.0 Strain (%) 3 1.6 2.0-2.5 Humidity (%) - 8 11 165 Table 3. tuft properties 166 Fibres Number of test Af (mm2) Ffu (N) σfu (MPa) Ef (GPa) εfpick (%) Hemp 5 9.81 1701.00 173.35 (3%) 8.59 (11%) 1.45 (16%) Sisal 5 9.81 1467.00 137.25 (16%) 4.87 (36%) 2.31 (14%) Glass 5 1.05 708.00 668.50 (8%) 61.25 (2%) 1.32 (6%) (%) = Coefficient of Variation, Ffu= Maximum load mean, σfu= Tensile Strength mean, Ef= Young’s Modulus mean, εfpick= deformation peak mean 167 Comparing the mechanical properties of the fibres (according to [24][25][26]) with the experi- 168 mental results of the tuft, a significant reduction in tensile strength and modulus of elasticity can 169 be observed. This due to the nonuniformity in the yarn’s structures. 170 171
Table 4. Fabrics properties 172 Mesh Hemp Sisal Glass Tuft direction Warp Weft Warp Weft Warp Weft Equivalent thickness (mm) 0.327 0.013 0.327 0.013 0.04 0.04 Yarns/tuft (-) 2 2 - Tensile strength of tuft (MPa) 173.35 520.76 137.25 520.76 668.50 668.50 Tensile strength of mesh (KN/m) 40.88 6.81 48.9 6.81 23.40 23.40 Strain (%) 1.45 1.30 2.31 1.30 1.32 Weight/area (g/m2) 682 609 225 173 2.3 Connectors 174 In order to evaluate the influence of the use of connectors on the bending mechanical 175 behavior of sandwich panels, connectors of different types of materials were used. The 176 connectors were of hemp, sisal, steel and mortar (only mortar in the hole of the polyure- 177 thane). Hemp and sisal were chosen for being the vegetal fibres used in this study for the 178 manufacture of vegetal fabrics, and steel was chosen for being the most commercial ma- 179 terial used as a connector in these types of panels. 180 In the case of the vegetal fibres connectors, hook-shaped connectors impregnated by 181 epoxy resin were created, with an equivalent area of 29.43 mm2 (6 yarns), and for the 182 steel connectors, a pin or bolt with a cross-sectional area of 0.79 mm2, and a nut one at 183 the end to improve the anchoring with the mortar (see Figure 3). 184 185 Figure 3. Connectors: (a) hemp, (b) sisal, (c) steel 186 2.3 Extruded polystyrene 187 188 Rigid Extruded Polystyrene foam boards with a thickness of 40 mm were used as the 189 insulating core of the vegetal-FRCM sandwich panels. 190 2.4 Specimens 191 The experimental campaign included 39 samples of sandwich panels. The dimensions of 192 the specimens were of 300×1000 mm and a thickness of 80 mm that is enough to create 193 a relevant flexural deformation (see Figure 5). These 39 samples included 4 different 194
connectors (steel, hemp, sisal and only mortar), 2 different distances between connectors, 195 and 3 different reinforcement fabrics (hemp, sisal and glass). 196 The mold to manufacture the sandwich panel specimens were prepared with a grid of 197 wooden strips defining 300 mm x 1000 mm gaps (see Figure 4). These strips had a height 198 of 90 mm. The manufacturing procedure was as follows: 199 Preparing the mold with demolding agent. 200 Placing first layer of mortar until more or less 15 mm 201 Placing the fabric so it slightly penetrated this first layer of mortar, 202 Cover the fabric with the second layer of mortar to reach the thickness of 20 mm 203 of the bottom FRCM wythes. 204 Placing the extruded polystyrene boards. In the case of Panels with connectors 205 this had hole in the defined positions for connectors. 206 Placing third layer of mortar to reach the thickness of 15 mm 207 Placing the second fabric so it slightly penetrated this first layer of mortar 208 In the case of panels with connectors, placing the connectors so that the top is 209 above the fabric. 210 Cover the second fabric (and connectors) with the fourth layer of mortar to reach 211 the thickness of 20 mm of the top FRCM wythes. 212 Demould and leave samples to cure in laboratory conditions for 28 days. 213 214 215 Figure 4. Manufacturing of sandwich panels: (a) without connectors, (b) with connectors 216
217 Figure 5. Sandwich panels 218 All specimens were measured to check the dimensions. It was found some small 219 deviations at a certain point, less than 2 mm, and it was assumed acceptable. The 220 nomenclature used for naming the panels is show in Table 5. 221 222 Table 5. Nomenclature of sandwich panels 223 Fibres Number of Connectors Connectors Numbers of Panels SH-0N Hemp 0 Without 3 SH-3H Hemp 3 Hemp 3 SH-5H Hemp 5 Hemp 3 SH-3S Hemp 3 Sisal 3 SH-5S Hemp 5 Sisal 3 SH-3St Hemp 3 Steel 3 SH-5St Hemp 5 Steel 3 SH-3M Hemp 3 Mortar 3 SH-5M Hemp 5 Mortar 3 SS-3S Sisal 3 Sisal 3 SS-5S Sisal 5 Sisal 3 SG-3St Glass 3 Steel 3 SG-5St Glass 5 Steel 3 224 3 Experimental campaigns 225 3.1 Test setup and instrumentation 226 The specimens were tested under a four-point bending test with a free span between 227 supports of 900 mm in length (see Figure 6). The supports were steel bar (free rotation). 228 The load was applied using a hydraulic actuator of 50 kN, and transferred to the tested 229 specimens through a steel distribution pate with two application edges (steel bar of 18 230 mm of diameter) separated 100 mm. The deflections were obtained using two 231 potentiometers placed under the panel in the position of the line load. All data were 232 continuously recorded at a frequency of 50 Hz using a data acquisition system. Also was 233 used a load cell of 10 kN placed in between the actuator and the steel distribution pate. 234 The test rate was 5 mm/min. 235
236 Figure 6. Test set up 237 3.2 Experimental results 238 3.2.1 Crack patterns 239 Figure 7 shows the crack patterns at failure. The specimens presented a classical flexural 240 failure. First appeared flexural cracks that spread through the tensile side of the speci- 241 mens, and finally the final failure occurs, which could be due to breakage of the fabric or 242 core of extruded polystyrene. 243 244 245 Figure 7. Type of failures 246 The sandwich panels presented two types of failures: 247 Cracks distribution and shear failures: this occurred in hemp-FRCM, where the 248 fabrics not reach its tensile strength, and the panels failed because de polystyrene 249 presented shear failures (see Figure 7a). Also, this presented better cracks 250 distribution than the other type of failures. 251
case of cracking displacement where is reach variation between 10 and 41%, this 401 can be for the great variation in this stage in the experimental results (11-34%). 402 b) Panels with sisal and glass fabric: the moments displacement and bending stiff- 403 ness, sufficiently close to the experimental results, with differences ranging from 404 1 to 14%. 405 Results presented in Table 7 are better appreciated in Figure 14. This presents the compar- 406 ison of the moment-displacement diagrams obtained from the numerical models and those 407 experimentally obtained for each type of panels. This shows how the results obtained 408 from the numerical simulation properly fit with the experimental results, where it shows 409 two types of curves, one where the moment reduces slowly when the curve reaches the 410 maximum moment (panels with hemp fabric), because the fabric had not reached the ten- 411 sile strength, but the polypropylene failed, and another where the curve drops suddenly 412 (panels with sisal and glass fabric), because the fabrics have reached the tensile strength. 413 414 415 Figure 14. Moment-displacement diagrams: (a) Hemp-FRCM, (b) Sisal-FRCM, (c) Glass-FRCM 416 5 Conclusions 417 In this work, an experimental and numerical research was conducted to investigate the 418 flexural performance of sandwich panels with composite vegetal-FRCM skins and 419 polystyrene core. According the achieved results: 420 ● The sandwich panel with hemp-FRCM presented more flexural strength, without 421 reaching the fabric ruptures (cracks distribution and shear failures), however in 422 panels with sisal and glass FRCM the fabrics reach the rupture. 423 ● From panels with 3 connectors, the connectors that provide greater stiffness were 424 the steel, followed by those of hemp, and sisal respectively. However, the initial 425 stiffness of panels with 5 hemp connectors presented similar stiffness than the 426 steel ones. 427 ● The number of connectors does not significantly influence the maximum moment 428 and the deflection of the panels with sisal and glass FRCM, because the premature 429 rupture of the fabrics. 430 ● The experimental results presented less dispersion in the first section of the 431 moment-displacement curve for panels with 5 connectors than with 3 connectors, 432
which means that it is improve the composite action between the materials when 433 5 connectors are placed. 434 ● Experimental results showed a promising substitution of synthetic fabrics by 435 means of more sustainable solutions made of vegetal FRCM 436 ● The numerical simulation was useful to reproduce the experimental behavior of 437 the specimen with 5 connectors, this because the composite action in this 438 specimen was more complete than the specimen with 3 connectors, and the 439 numerical models consider a tie contact between materials (polyurethane and 440 mortar).The numerical simulation was useful to determine the maximum and 441 cracking moment and maximum bending stiffness with differences ranging 442 between 2 and 8 % for panels with hemp-FRCM, but the cracking displacement 443 was variation between 10 and 41%. However, in the panels with sisal and glass 444 fabric: the moments, displacement and bending stiffness, were sufficiently close 445 to the experimental results, with differences ranging from 1 to 14%. 446 447 Acknowledgements 448 This study has been partially carried out within the project ‘‘Desarrollo de paneles 449 industriales prefabricados tipo sándwich con materiales compuestos de matriz cementicia 450 (FRCM) y con digitalización BIM incorporada. PANELPLUS’’, funded by the Spanish 451 Ministry of Science, Innovation and University through the Torres Quevedo program. 452 The materials support of Sika AG and Mapei Spain S.A. is acknowledged. 453 Authors want to thanks the research project SEVERUS (RTI2018-099589-B-I00) of the 454 Spanish Research Agency. The contribution of PhD. Lluis Gil is also acknowledged. 455 Second author is a Serra Húnter Fellow. 456 457 References 458 [1] H. a. Gleich, New Carbon Fiber Reinforcement Advances Sandwich Wall Panels, 459 Prod. Watch. (2007) 61–63. 460 [2] E.D. Losch, P.W. Hynes, R. Andrews, R. Browning, P. Cardone, R. Devalapura, 461 R. Donahey, S. Freedman, H.A. Gleich, G. Goettsche, P. Kourajian, J. Krohn, C. 462 Leaton, Z. Li, R. Long, D. Meinheit, M. Milkovitz, B. Miller, F. Nadeau, B. 463 Nesset, S. Pessiki, D.N. Peterson, S.H. Peterson, R. Quiroga, S. Reay, W. 464 Richardson, K. Seeber, V. Seshappa, D. Smith, B. Trimbath, K. Truderung, M. 465 Wagner, C. Wynings, L. Yan, State of the art of precast/prestressed concrete 466 sandwich wall panels, PCI J. 56 (2011) 131–176. 467 [3] R. O’Hegarty, O. Kinnane, Review of precast concrete sandwich panels and their 468 innovations, Constr. Build. Mater. 233 (2020) 117145. 469 https://doi.org/10.1016/j.conbuildmat.2019.117145. 470 [4] Y.J. Kim, A. Allard, Thermal response of precast concrete sandwich walls with 471 various steel connectors for architectural buildings in cold regions, Energy Build. 472 80 (2014) 137–148. https://doi.org/10.1016/j.enbuild.2014.05.022. 473 [5] N. Williams Portal, M. Flansbjer, K. Zandi, L. Wlasak, K. Malaga, Bending 474 behaviour of novel Textile Reinforced Concrete-foamed concrete (TRC-FC) 475 sandwich elements, Compos. Struct. 177 (2017) 104–118. 476 https://doi.org/10.1016/j.compstruct.2017.06.051. 477 [6] T. Voellinger, A. Bassi, M. Heitel, Facilitating the incorporation of VIP into 478 precast concrete sandwich panels, Energy Build. 85 (2014) 666–671. 479 https://doi.org/10.1016/j.enbuild.2014.05.038. 480
[7] A. Shams, M. Horstmann, J. Hegger, Experimental investigations on textile- 481 reinforced concrete (TRC) sandwich sections, Compos. Struct. 118 (2014) 643– 482 653. https://doi.org/10.1016/j.compstruct.2014.07.056. 483 [8] I.G. Colombo, M. Colombo, M. di Prisco, Precast TRC sandwich panels for 484 energy retrofitting of existing residential buildings: full-scale testing and 485 modelling, Mater. Struct. Constr. 52 (2019) 1–16. 486 https://doi.org/10.1617/s11527-019-1406-1. 487 [9] D.H. Shin, H.J. Kim, Composite effects of shear connectors used for lightweight- 488 foamed-concrete sandwich wall panels, J. Build. Eng. 29 (2020) 101108. 489 https://doi.org/10.1016/j.jobe.2019.101108. 490 [10] C. Naito, J. Hoemann, M. Beacraft, B. Bewick, Performance and 491 Characterization of Shear Ties for Use in Insulated Precast Concrete Sandwich 492 Wall Panels, J. Struct. Eng. 138 (2012) 52–61. 493 https://doi.org/10.1061/(asce)st.1943-541x.0000430. 494 [11] L. Miccoli, P. Fontana, G. Johansson, K. Zandi, N.W. Portal, U. Müller, 495 Numerical modelling of UHPC and TRC sandwich elements for building 496 envelopes, IABSE Conf. Geneva 2015 Struct. Eng. Provid. Solut. to Glob. 497 Challenges - Rep. (2015) 195–203. 498 https://doi.org/10.2749/222137815818357089. 499 [12] W. I. Goh, N. Mohamad, R. Abdullah, A.A. A. Samad, Finite Element Analysis 500 of Precast Lightweight Foamed Concrete Sandwich Panel Subjected to Axial 501 Compression, J. Comput. Sci. Comput. Math. (2016) 1–9. 502 https://doi.org/10.20967/jcscm.2016.01.001. 503 [13] C. Frazão, J. Barros, R. Toledo Filho, S. Ferreira, D. Gonçalves, Development of 504 sandwich panels combining Sisal Fiber-Cement Composites and Fiber- 505 Reinforced Lightweight Concrete, Cem. Concr. Compos. 86 (2018) 206–223. 506 https://doi.org/10.1016/j.cemconcomp.2017.11.008. 507 [14] R. Codispoti, D. V. Oliveira, R.S. Olivito, P.B. Lourenco, R. Fangueiro, 508 Mechanical performance of natural fiber-reinforced composites for the 509 strengthening of masonry, Compos. Part B Eng. 77 (2015) 74–83. 510 https://doi.org/10.1016/j.compositesb.2015.03.021. 511 [15] M. Ardanuy, J. Claramunt, R.D. Toledo Filho, Cellulosic fiber reinforced 512 cement-based composites: A review of recent research, Constr. Build. Mater. 79 513 (2015) 115–128. https://doi.org/10.1016/j.conbuildmat.2015.01.035. 514 [16] M. De Munck, T. Tysmans, M. El Kadi, J. Wastiels, J. Vervloet, P. Kapsalis, O. 515 Remy, Durability of sandwich beams with textile reinforced cementitious 516 composite faces, Constr. Build. Mater. 229 (2019) 116832. 517 https://doi.org/10.1016/j.conbuildmat.2019.116832. 518 [17] H. Ahmad, M. Fan, Interfacial properties and structural performance of resin- 519 coated natural fibre rebars within cementitious matrices, Cem. Concr. Compos. 520 87 (2018) 44–52. https://doi.org/10.1016/j.cemconcomp.2017.12.002. 521 [18] F. Micelli, M.A. Aiello, Residual tensile strength of dry and impregnated 522 reinforcement fibres after exposure to alkaline environments, Compos. Part B 523 Eng. (2016). https://doi.org/10.1016/j.compositesb.2017.03.005. 524 [19] J. Donnini, V. Corinaldesi, Mechanical characterization of different FRCM 525 systems for structural reinforcement, Constr. Build. Mater. 145 (2017) 565–575. 526 https://doi.org/10.1016/j.conbuildmat.2017.04.051. 527 [20] T. D’Antino, C. Papanicolaou, Mechanical characterization of textile reinforced 528 inorganic-matrix composites, Compos. Part B Eng. 127 (2017) 78–91. 529 https://doi.org/10.1016/j.compositesb.2017.02.034. 530
[21] EN 1504-3, EN 1504-3 Products and systems for the protection and repair of 531 concrete structures - Definitions, requirements, quality control and evaluation of 532 conformity - Part 3: Structural and non-structural repair, Http://Www.Aenor.Es/. 533 (2005). 534 http://www.aenor.es/aenor/normas/normas/fichanorma.asp?tipo=N&codigo=N00 535 37931#.WgV3CmjWzcs (accessed November 10, 2017). 536 [22] L. Mercedes, L. Gil, E. Bernat-maso, Mechanical performance of vegetal fabric 537 reinforced cementitious matrix ( FRCM ) composites, Constr. Build. Mater. 175 538 (2018) 161–173. https://doi.org/10.1016/j.conbuildmat.2018.04.171. 539 [23] L. Mercedes, E. Bernat-Maso, L. Gil, In-plane cyclic loading of masonry walls 540 strengthened by vegetal-fabric-reinforced cementitious matrix (FRCM) 541 composites, Eng. Struct. 221 (2020) 111097. 542 https://doi.org/10.1016/j.engstruct.2020.111097. 543 [24] P. Wambua, J. Ivens, I. Verpoest, Natural fibres: Can they replace glass in fibre 544 reinforced plastics?, Compos. Sci. Technol. 63 (2003) 1259–1264. 545 https://doi.org/10.1016/S0266-3538(03)00096-4. 546 [25] R.S. Olivito, O.A. Cevallos, A. Carrozzini, Development of durable cementitious 547 composites using sisal and flax fabrics for reinforcement of masonry structures, 548 Mater. Des. 57 (2014) 258–268. https://doi.org/10.1016/j.matdes.2013.11.023. 549 [26] C. Rosamaria, Mechanical Performance of Natural Fiber-Reinforced Composites 550 for the Strengthening of Ancient Masonry, University of Calabria, 2013. 551 [27] Simulia, Abaqus 6.14. User´s Manual, (2011). 552 [28] L. Mercedes, E. Bernat-Maso, L. Gil, Numerical simulation of masonry walls 553 strengthened with vegetal fabric reinforced cementitious matrix (FRCM) 554 composites and subjected to cyclic loads, Structures. (2021) 1–11. 555 https://doi.org/10.1016/j.istruc.2021.09.010. 556 [29] L. Mercedes, E. Bernat-maso, L. Gil, Flexural failure of fabric reinforced 557 cementitious mortar ( FRCM ) plates under punctual loads : Experimental test , 558 analytical approach and numerical simulation, Constr. Build. Mater. 272 (2021) 559 121651. https://doi.org/10.1016/j.conbuildmat.2020.121651. 560 [30] L. Mercedes, C. Escrig, E. Bernat-Masó, L. Gil, Analytical approach and 561 numerical simulation of reinforced concrete beams strengthened with different 562 frcm systems, Materials (Basel). 14 (2021). https://doi.org/10.3390/ma14081857. 563 [31] B. Alfarah, F. López-Almansa, S. Oller, New methodology for calculating 564 damage variables evolution in Plastic Damage Model for RC structures, Eng. 565 Struct. 132 (2017) 70–86. https://doi.org/10.1016/j.engstruct.2016.11.022. 566 [32] E. Bertolesi, F.G. Carozzi, G. Milani, C. Poggi, Numerical modeling of Fabric 567 Reinforce Cementitious Matrix composites (FRCM) in tension, Constr. Build. 568 Mater. 70 (2014) 531–548. https://doi.org/10.1016/j.conbuildmat.2014.08.006. 569 [33] L. Mercedes, E. Bernat-maso, L. Gil, Flexural failure of fabric reinforced 570 cementitious mortar ( FRCM ) plates under punctual loads : Experimental test , 571 analytical approach and numerical simulation, Constr. Build. Mater. (2020) 572 121651. https://doi.org/10.1016/j.conbuildmat.2020.121651. 573 [34] Ministerio de Fomento. Comisión Permanente del Hormigón., EHE-08 Intrucción 574 de Hormigon Estructural, 2011. 575 https://doi.org/10.1017/CBO9781107415324.004. 576 [35] E. Bertolesi, G. Milani, C. Poggi, Simple holonomic homogenization model for 577 the non-linear static analysis of in-plane loaded masonry walls strengthened with 578 FRCM composites, Compos. Struct. 158 (2016) 291–307. 579 https://doi.org/10.1016/j.compstruct.2016.09.027. 580
[36] J. Vervloet, T. Tysmans, M. El Kadi, M. De Munck, P. Kapsalis, P. Van 581 Itterbeeck, J. Wastiels, D. Van Hemelrijck, Experimental and numerical 582 evaluation of textile reinforced cement (TRC) sandwich walls in compression: A 583 geometrical study, Constr. Build. Mater. 240 (2020) 117904. 584 https://doi.org/10.1016/j.conbuildmat.2019.117904. 585 586 587