scieee AI-readable full text Open interactive document viewer

Ground-level ozone concentration over Spain: an application of Kalman Filter post-processing to reduce model uncertainties

Sicardi, Valentina,Ortiz, Joana,Rincón, Ángel,Jorba Casellas, Oriol,Pay Pérez, M. Teresa,Gassó Domingo, Santiago,Baldasano Recio, José María

Abstract

The CALIOPE air quality modelling system, namely WRF-ARW/HERMESEMEP/ CMAQ/BSC-DREAM8b, has been used to perform the simulation of ground level O3 concentration for the year 2004, over the Iberian Peninsula. We use this system to study 5 the daily ground-level O3 maximum. We investigate the use of a post-processing such as the Kalman Filter bias-adjustment technique to improve the simulated O3 maximum. The Kalman Filter bias-adjustment technique is a recursive algorithm to optimally estimate bias-adjustment terms from previous measurements and model results. The bias-adjustment technique is found to improve the simulated O3 maximum for the en10 tire year and the whole domain. The corrected simulation presents improvements in statistical indicators such as correlation, root mean square error, mean bias, standard deviation, and gross error. After the post-processing the exceedances of O3 concentration limits, as established by the European Directive 2008/50/CE, are better reproduced and the uncertainty of the modelling system is reduced from 20% to 7.5%. Such un15 certainty in the model results is under the established EU limit of the 50%. Significant improvements in the O3 average daily cycle and in its amplitude are also observed after the post-processing. The systematic improvements in the O3 maximum simulations suggest that the Kalman Filter post-processing method is a suitable technique to reproduce accurate estimate of ground-level O3 concentration.

Full text

GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Geosci. Model Dev. Discuss., 4, 343–384, 2011 www.geosci-model-dev-discuss.net/4/343/2011/ doi:10.5194/gmdd-4-343-2011 © Author(s) 2011. CC Attribution 3.0 License. Geoscientific Model Development Discussions This discussion paper is/has been under review for the journal Geoscientific Model Development (GMD). Please refer to the corresponding final paper in GMD if available. Ground-level ozone concentration over Spain: an application of Kalman Filter post-processing to reduce model uncertainties V. Sicardi1, J. Ortiz1, A. Rinc ´ on1, O. Jorba1, M. T. Pay1, S. Gass´ o1,2, and J. M. Baldasano1,2 1Barcelona Supercomputing Center – Centro Nacional de Supercomputaci´ on, Spain 2Laboratory of Environmental Modeling, Universitat Polit` ecnica de Catalunya (LMA-UPC), Spain Received: 1 February 2011 – Accepted: 4 February 2011 – Published: 15 February 2011 Correspondence to: V. Sicardi ([email protected]) Published by Copernicus Publications on behalf of the European Geosciences Union. 343 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Abstract The CALIOPE air quality modelling system, namely WRF-ARW/HERMESEMEP/CMAQ/BSC-DREAM8b, has been used to perform the simulation of ground level O3concentration for the year 2004, over the Iberian Peninsula. We use this system to study the daily ground-level O3maximum. We investigate the use of a post-processing5 such as the Kalman Filter bias-adjustment technique to improve the simulated O3maxi- mum. The Kalman Filter bias-adjustment technique is a recursive algorithm to optimally estimate bias-adjustment terms from previous measurements and model results. The bias-adjustment technique is found to improve the simulated O3maximum for the entire year and the whole domain. The corrected simulation presents improvements in10 statistical indicators such as correlation, root mean square error, mean bias, standard deviation, and gross error. After the post-processing the exceedances of O3concentra- tion limits, as established by the European Directive 2008/50/CE, are better reproduced and the uncertainty of the modelling system is reduced from 20% to 7.5%. Such uncertainty in the model results is under the established EU limit of the 50%. Significant15 improvements in the O3average daily cycle and in its amplitude are also observed after the post-processing. The systematic improvements in the O3maximum simulations suggest that the Kalman Filter post-processing method is a suitable technique to reproduce accurate estimate of ground-level O3concentration. 1 Introduction20 Ozone pollution is one of the main concerns in Europe and in particular in the Mediterranean area (Baldasano et al., 1994, 2003; Mill´ an et al., 1997; Gangoiti et al., 2001; Gerasopoulos et al., 2005; Jim´ enez et al., 2005a, 2006; Cristofanelli and Bonasoni, 2009). Meteorological factors affect the O3concentrations and in Spain, due to the prevailing meteorological stable conditions, the emissions patterns, and the topogra-25 phy, the O3pollution is a crucial, but already addressed problem (Mill´ an et al., 2002; 344 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Jim´ enez and Baldasano, 2004; Jim´ enez et al., 2005b, 2008). Elevated concentrations of tropospheric O3may lead to adverse effects on human health, agricultural crops, forests and materials (Brauer et al., 1997; West et al., 2007; WHO, 2008; Finlayson- Pitts, 2010). The European air quality Directive 2008/50/EC defines target values and long-term5 objectives for the protection of human health and vegetation. The objective target value for human health protection is 120 µg m−3(calculated as daily maximum averaged over 8 h running mean) and is not to be exceeded on more than 25 days per year averaged over 3 yr. The information threshold must be given to the population when hourly means exceed 180 µg m−3, and the alert threshold should be issued if hourly means exceed10 240 µg m−3. Modelling techniques are valid and recognized means to monitor and predict the air quality and the reliability of such models is essential. The air quality CALIOPE system, namely WRF-ARW/HERMES-EMEP/CMAQ/BSCDREAM8b, operatively applied under the Spanish government founded project CALIOPE (Baldasano et al., 2008a) has been used to perform hindcasts of tropo-15 spheric O3over Spain for the year 2004. The CALIOPE modelling system has been used in previous studies to assess the air quality over Europe and Spain (Pay et al., 2010; Baldasano et al., 2010). Comparisons of O3model results with observations have revealed that even though the temporal variability in O3is well simulated, further improvement in the O3simulations are still needed.20 In order to produce more accurate simulations, we post-process the model results with a bias-adjustment technique (Kang et al., 2008). We carry out the simulation of ground level O3concentration over Spain, for the year 2004, and analyze the results produced by the modelling system (hereafter model results) and after the application of Kalman Filter bias-adjustment technique (hereafter KF-output). The Kalman Filter25 (Kalman, 1960), already applied in previous studies of atmospheric pollution modelling, reduces the error in the model results by the application of recent bias of the forecast and observations to produce an adjusted forecast (Delle Monache et al., 2006; Kang et al., 2008, 2010). The Kalman Filter is a versatile and rapid bias-adjustment 345 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | technique that is applied to point stations and when observations are available. Both the model results and KF-output are tested over a set of stations located throughout the domain. Models always have uncertainties due to the data limitations and incomplete representation of the physical/chemical mechanisms; this introduces errors in the model results (Borrego, 2003; Chang and Hanna, 2004; Flemming and Stern, 2007).5 The uncertainty of the model results is calculated and checked against the European Directive 2008/50/CE; hence, the improvement achieved by the post-process is verified. An analysis of the main statistical parameters is also carried out together with an analysis of the daily cycle and their improvement achieved by the application of the post-processing.10 In this work we investigate the reliability of the CALIOPE air quality system in reproducing O3daily maximum, the improvements in the O3simulation and the reduction of the model uncertainties after the post-processing. This paper is organized as follow: Sect. 2 contains a model overview and a description of the air quality observation network; in Sect. 3 is introduced the Kalman Filter and the uncertainty calculation. In15 Sect. 4 are presented the results and in Sect. 5 the conclusions. 2 Methods 2.1 Modelling system The CALIOPE air quality modelling system is a state-of-the-art modelling framework (www.bsc.es/caliope). It is a complex system that integrates the meteorological model:20 WRF-ARW; the emission model: HERMES; the chemical transport model: CMAQ; and the mineral dust atmospheric model: BSC-DREAM8b offline coupled in an air quality forecasting system (Baldasano et al., 2008a). The Advanced Research Weather Research and Forecasting (WRF-ARW) model v3.0.1.1 (Michalakes et al., 2004; Skamarock et al., 2005; Skamarock and Klemp,25 2008) provides the meteorology conditions. For the Iberian Peninsula (IP) domain 346 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | WRF-ARW is configured with a grid of 397×397 points corresponding to a 4 km×4 km horizontal resolution and 38σvertical levels with 11 characterizing the planetary boundary layer (PBL). The model top is defined at 50 hPa to resolve the tropospherestratosphere exchanges. The Models-3 Community Multiscale Air Quality Modelling System (Models-3/CMAQ,5 Byun and Ching, 1999; Binkowski, 1999; Byun and Schere, 2006), v4.5 is used to study the behavior of air pollutants from regional to local scales. It includes gas, aerosol and heterogeneous chemistry. According to Jim´ enez et al. (2003) the gas-phase chemistry mechanism used is the Carbon Bond IV (CBM-IV, Gery et al., 1989). The version of CBM-IV mechanism is that presented in CMAQv4.5 original code (Appel et al., 2007)10 which introduces some changes and updates in the original CBM-IV mechanism such as an updating isoprene chemistry to Carter’s one product form (Carter, 2000) and an inclusion of gaseous species that are necessary to link gas-phase chemistry to aerosol formation. The aerosols are modeled using the AERO4 module (Binkowski and Roselle, 2003). Secondary inorganic aerosols (SIA) are generated by nucleation15 processes from their precursors to form nitrate ammonium and sulfate aerosols. The thermodynamic equilibrium between gas and inorganic fine aerosols is determined by the ISORROPIA model (Nenes et al., 1998). The CMAQ horizontal grid resolution corresponds to that of WRF. Its vertical structure was obtained by a collapse from the 38 WRF layers to a total of 15 layers steadily20 increasing from the surface up to 50 hPa with a stronger density within the PBL. In order to provide adequate boundary and initial conditions to the IP domain the CALIOPE modelling system was initially run on a regional scale (12 km×12 km in space and 1 h in time) to model the European domain (mother domain). Chemical boundary conditions for this domain were provided by the global climate chemistry model LMDz-25 INCA2 (Hauglustaine et al., 2004; Folberth et al., 2006). A one-way nesting was then performed to retrieve the meteorological and chemical conditions for the IP domain (Fig. 1). 347 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | The HERMES model (Baldasano et al., 2008b) uses information and state-of-the- art methodologies for emission estimations. It calculates emissions by sector-specific sources or by individual installations and stacks. Emissions used for Spain are derived from the aggregation in space from 1 km×1 km dataset to 4 km×4 km. Raw emission data are processed by HERMES in order to provide a comprehensive description of5 the emissions to the air quality model. In this study the emissions are expressed in CBM-IV speciation. Regarding to biogenic emissions, HERMES calculates the biogenic volatile organic compounds (bVOC) from vegetation. Three categories of bVOC are estimated according to their reactivity: isoprene, monoterpenes and other volatile organic compounds (OVOC). The model considers the influence of temperature and10 photosynthetically active radiation (PAR) by Guenther et al. (1995) algorithms, according to Parra et al. (2004, 2006). Emission factors for each individual vegetal species are associated with emitter land-use categories. The land-use categories for each grid cell are obtained from CORINE Land Cover 2000 map starting with a resolution of 100 m, and adapting to 22 the land-use categories according to Ar´ evalo et al. (2004).15 In the updated version of HERMES model used in the present work, the influence of seasonality in the emission of bVOC is introduced through an environmental correction factor following Staudt et al. (2000) and Steinbrecher et al. (2009). The Dust REgional Atmospheric Model (BSC-DREAM8b) was designed to simulate and predict the atmospheric cycle of mineral dust (Nickovic et al., 2001; P´ erez et al.,20 2006a, b). The domain considered in this study comprises northern Africa, the Mediterranean basin and Europe. BSC-DREAM8b is fully embedded within the NCEP/Eta meteorological driver (Janjic, 1994). It simulates the long-range transport of mineral dust at a 0.3◦×0.3◦resolution using 24 vertical layers extending up to 15 km in altitude on an hourly basis. The aerosol description contains 8 bins to allow a fine description of25 dust aerosols. Dust-radiation interactions are calculated online. An offline coupling is applied to the calculated concentrations of particulate matter from CMAQ (Jim´ enez et al., 2008). 348 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | This modelling system has been evaluated in depth; a detailed evaluation of the European domain is presented in Pay et al. (2010), and for the IP domain in Baldasano et al. (2010). For a detailed description of the evaluation of this system we refer to these studies. The simulation has been carried out for the full year 2004 and for the same period has been done the statistical analysis of the model skills. For the daily5 cycle analysis, only the data from the ozone campaign (April to September) have been analyzed. The ground level O3concentration has been taken into account as representative of the surface concentration and compared with observations. 2.2 Observations The model simulations are tested against the hourly observations from a network of 8210 stations (hereafter referred as RedESP) covering the entire Spanish territory (Fig. 1). The hourly measurements provided by “Centro de Estudios Ambientales del Mediterraneo (CEAM)”, were subjected by a preliminary quality control. Monitoring data were available for the full year 2004, but only stations with temporal coverage of 85% were taken into account and compared with the model results. The temporal minimum data15 coverage of 90% as recommended in the Directive 2008/50/EC, refers to the data without calibration and maintenance, thus it reduces to minimum data coverage of 85% after the quality control (Garber et al., 2002). The air quality monitoring stations are classified as urban, suburban and rural according to their locations (Garber et al., 2002; Annex III of the Directive 2008/50/EC).20 To extract the model results corresponding to the stations considered we apply two procedures: for the urban and suburban station the mean value of the corresponding 4×4 km grid cell has been taken. For the rural stations it has been done a bilinear interpolation with the closest cells. All the statistics are calculated for all the stations and no weight has been given to the different stations type. We compute the daily maximum25 of the hourly data (max. 1-h) and the daily maximum of the 8 h running average (max. 8-h) for each station over the full year and compare them with the observations. When computing the daily maximum, for both hourly and 8-h averaged data, only the days 349 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | with a minimum of 75% of hourly data have been taken into account (according to the Spanish project to national law for air quality, 2010). Following this criterion 24 days of the entire year have been eliminated in the case of the max. 1-h calculation and 27 days in the case of max. 8-h calculation. 3 Post – processing and uncertainty5 3.1 The Kalman Filter The model results have been post-processed by the application of the Kalman Filter Predictor. The Kalman Filter Predictor is a post-processing method that uses recent estimates and measurements to revise and improve the current estimate (Kalman, 1960) and it has been applied in previous O3studies (Delle Monache et al., 2006, 2008; Kang10 et al., 2008). In Kang et al. (2008) a thorough discussion about the error ratio is presented and it is demonstrated that even though the optimal error ratios vary in space, the impact of using different optimal values over the model domain on the resultant bias-adjusted forecast was insignificant when compared to a representative fixed value for all locations. To test whether the same conclusion is valid for our O3simulation,15 error ratios ranging from 0.01 to 2 have been selected for all the stations considered over the entire year 2004. Root mean square error and correlation coefficient values have been calculated to gauge the impact of spatially different error ratio values on the performance (Fig. 2). Based on this approach we finally use an optimal value varying seasonally for all the stations (Table 1).20 When using seasonally varying values, the O3simulation is found to improve. Nevertheless, it is assessed that O3simulation over different areas (e.g. rural versus urban), or for different model results may have different optimal ratio values (Delle Monache et al., 2006; Kang et al., 2010). It is also worth noting that the Kalman Filter is applied only to discrete points (mon-25 itoring stations) and then an average is taken to have a representation of the whole 350 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | domain. The complexity of the domain and the difference in emissions sources over the domain suggest that, further research is needed to extend the correction to the whole domain (Kang et al., 2010). 3.2 Uncertainty and statistics The model uncertainties can be associated with model formulation regarding misrep-5 resentation of atmospheric dynamics and chemistry, numerical solutions, choice of modelling domain and grid structure; with the model input regarding emissions, meteorological data; or with the stochastic processes that are not known (Borrego et al., 2008; Chang and Hanna, 2004). Reducing the uncertainties is fundamental in order to obtain high quality model re-10 sults. In the European Directive 2008/59/CE, “the uncertainty for modelling is defined as the maximum deviation of the measured and calculated concentration levels for 90% of individual monitoring points, over the period considered, by the limit value (or target value in the case of ozone) without taking into account the timing of the events. The uncertainty for modelling shall be interpreted as being applicable in the region of the15 appropriate limit value (or target value in the case of ozone). The fixed measurements that have to be selected for comparison with modelling results shall be representative of the scale covered by the model”. The “without timing” in the above definition, implies that the time factor is not taken into consideration, nor the sequences of the events (e.g. when an exceedance of concentration limit occurs), which is fundamental in the20 case of air quality forecast systems. The Guidance on the use of models for the European air quality directive proposes the statistic calculations needed to validate the air quality models and their related uncertainties (Denby et al., 2010). The uncertainty calculated for a single station is defined mathematically as the “Relative Directive Error” (RDE) (Eq. 1):25 RDE =OLV −MLV LV (1) 351 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | of false alarm, improves after post-processing the data. In this way the false alerts for the population would be reduced. Finally the Critical Success Index (CSI) indicates how well both the observed exceedances and the false exceedances are projected, the ideal value would be 1. For both the max. 1-h and the max. 8-h the application of the post-processing improves this value. Unlike the POD and the FAR, the CSI takes5 into account both false alarms and missed events, and it is therefore a more balanced score. 4.3 Daily cycle To detect common periodicities, a standard method of time-series analysis has been used: computing the Fourier transform and plotting the power density spectrum over10 the frequency. We compute the spectral analysis of the hourly data in order to catch the signal of characteristic periods as done in previous studies (Hies et al., 2000; Sebald et al., 2000; Marr et al., 2002). We use the periodogram method as estimate of the spectral density calculated in its simplest form: the squared amplitude in function of frequency (Alter, 1937). The time series is decomposed into spectral bands repre-15 senting the different time scales: intra-day, diurnal, synoptic, seasonal and long term fluctuations. The highest amplitudes of a spectrum indicate the main periodicities of the underlying processes (Fig. 8). The periodogram in Fig. 8 reveals the ability of the modelling system to capture the variability associated with synoptic to long-term scales. The annual cycle in the O3time series is not visible in this periodogram because of20 the limited data range, since the length of the record should be 10 times as long as the longest significant period (Hies et al., 2000). The results show poor model ability in representing the observed daily and intra-day variability. The modelling system shows a tendency to underestimate the high frequency variability (intra-day and hour-to-hour variability), a feature which is corrected by the post-processing. Such behaviour is25 further investigated by the temporal analysis of the daily cycle. We compute the average daily cycle of observed and simulated hourly ozone concentrations for both the model results and the KF-output (Fig. 9). The box plot helps to 358 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | visualize the distribution, its central value, and spread of the represented values. In the figure are depicted the lower and upper quartiles, and the median. The mean is overplotted for completeness. The overall daily cycle is reproduced by the model results: maximum O3values during day time and minimum during night. However, the model results show poor performance when representing the daily cycle amplitude and the5 extreme values. In the model results the amplitude of the daily cycle is underestimated (dimension of the boxes in Fig. 9), both the night minimum and the daytime maximum are underestimated while the overall mean value (overlaying line on the boxes) is overestimated. The simulation improves after applying the Kalman Filter: the amplitude of the cycle becomes well represented and the extreme values are better estimated10 (Fig. 9). A known problem of the air quality models is to reproduce the night minimum. The possible explications of such behaviour are examined by several previous studies. It is probable that the model chemistry does not represent properly ozone nighttime’s titration, therefore the model simulates a no production of O3, but omits the mechanism15 of O3consumption. Possible causes of the observed mismatch are the bad representation of the nocturnal boundary layer or the emissions injection profile (Appel et al., 2007; van Loon et al., 2007; Vautard et al., 2007; Chemel et al., 2010). 4.4 Model uncertainty The European Directive 2008/50/CE establishes that numerical models have to meet20 certain model quality, namely have a certain modelling uncertainty, to be considered suited for air quality assessment. The level of uncertainty associated with the air quality modelling is a crucial issue to take into account when evaluating an air quality performance. We compute the model uncertainty, expressed as MRDE, before and after the25 Kalman Filter post-processing to verify any improvements (Table 4). In both cases the computed uncertainty is well within the limit established by the European Directive 2008/50/CE that is 50%. The uncertainty of the model is 20% and 22% for the max. 359 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | 1-h and max. 8-h respectively, well under the uncertainty limit. This finding gives us confidence in the ability of CALIOPE system to represent the O3concentrations, even before the post-processing. Nevertheless the improvement of the uncertainty in case of post-processed KF-output is considerably: the uncertainty is reduced from 19% to 7.5% for the max. 1-h and max. 8-h respectively.5 The uncertainty, calculated in this way, indicates only whether the model is reliable or not. This definition of uncertainty must not be considered in terms of forecast interval, since it does not take into account the temporal information related to the formation/destruction of ozone. Furthermore, using this way of computing the uncertainty, the number of the exceedances is independent of the sequence of the events. This ap-10 proach is in contrast to a time-related process, in which the temporal correspondence is an important evaluation parameter, as it is in air quality studies. 5 Conclusions We use the CALIOPE air quality modelling system to reproduce the daily maximum of O3ground level concentration over Spain for the full year 2004. We calculate the15 O3daily maximum concentration at ground level over hourly data (max. 1-h) and over 8 h running average (max. 8-h). We use several statistical parameters in order to perform the model evaluation and check whether the modelling system meets the air quality EU Directive 2008/50/CE. We analyze the abilities of a post-processing technique, namely the Kalman Filter, to improve the O3simulation.20 The results indicate on one hand, that the model results represent the O3concen- tration with significant authenticity, but on the other hand, that the KF post-processing helps to achieve a more accurate match with the observations. By the analysis of the Correlation, Root Mean Square Error, Mean Bias, Standard Deviation of the Error, Mean Normalized Bias Error, and Mean Normalized Gross Error we observe a25 general improvement after the application of the Kalman Filter. Even the metrics associated with the categorical analysis display improvement after the KF post-process. 360 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | However, caution is needed when looking with those parameters at the categorical metrics. Accuracy, Bias and False Alarm are influenced by the number of exceedances and no-exceedances and, if analyzed alone, they are weak parameters for evaluating the model performance. Even though by the application of the Kalman Filter both the simulated exceedances (hits) and no-exceedances (false alarm) are better simulated,5 the value of False Alarm Ratio (FAR) is still quite high (KF: 0.512 and 0.41 for max. 1-h and max. 8-h respectively, ideal is 0). For the max. 1-h on a total of 127 exceedances observed, only 1 is simulated by the model and the 21 after the post-process, which means that only the 16% of the exceedances are well captured by the model. For the max. 8-h the percentage of hits increases to the 32%. This finding, if on one hand indi-10 cates that KF post-processing leads to improvements in the O3simulation, on the other hand, highlights that the number of the exceedances still remains underestimated. The Critical Success Index (CSI) and the Probability of Detection (POD) are more suitable to measure the model performance, since they take into account the misses of the model. Categorical statistics improve after the application of the Kalman Filter.15 The model results fall short in the prediction of the diurnal cycle, which is underestimated. Likely there are some crucial processes related to the resolution of the boundary layer, the emissions or the chemistry of NO-O3, missing in the modelling system. The O3daily cycle presents higher agreement with observations when KF post-processing is applied, for both daily amplitude and extreme values.20 The uncertainty calculated for the model results is within the limit proposed by the European Directive 2008/50/CE, which is 50%: the uncertainties are of 22% and 20% for max. 1-h and max. 8-h respectively. Notwithstanding for the KF-output the uncertainty is significantly reduced: 19% and 7.5% for max. 1-h and max. 8-h respectively. In this study the Kalman Filter is applied only to discrete points (82 measurements25 stations), hence, further investigation is needed in order to extend the bias correction to the full domain and produce bias corrected spatial maps. 361 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Acknowledgements. The authors wish to thank Luca Delle Monache and Ronald B. Stull for providing the Kalman Filter algorithm used in this study. All the computation has been done at the MareNostrum supercomputer hosted by the Barcelona Supercomputing Center-Centro Nacional de Supercomputaci´ on (BSC-CNS). This work is funded by the CALIOPE project of the Spanish Ministry of the Environment (441/2006/3-12.1, A357/2007/2-12.1, 157/PC08/3-12.0).5 References Alter, D.: A simple form of periodogram, Ann. Mat. Stat., 8, 2, 121–126, 1937. Appel, K. W., Bhave, P. V., Gilliland, A. B., Sarwar, G., and Roselle, S. J.: Evaluation of the community multiscale air quality (CMAQ) model version 4.5: Sensitivities impacting model performance; Part II-particulate matter, Atmos. Environ., 42, 6057–6066,10 doi:10.1016/j.atmosenv.2008.03.036, 2008. Ar´ evalo, G., Salvador, R., Gass´ o, S., Mill´ an, M., and Baldasano, J. M.: Application of a highresolution emission model in Valencia Community (Spain), Air Pollution 2004, WIT Press, Rhodes, Greece, 31–40, 2004 Baldasano, J. M., Valera, E., and Jim´ enez, P.: Air Quality Data from Large Cities, Sci. Total15 Environ., 307, 1–3, 141–165, 2003. Baldasano, J. M., Cremades, L., and Soriano, C.: Circulation of air pollutants over the Barcelona Geographical Area in summer, in: Proceedings of the Sixth European Symposium on Physico-Chemical Behaviour of Atmospheric Pollutants, Varese, Italy, 18–22 October 1993, Report EUR 15609/1, 474–479, 2004.20 Baldasano, J. M., Jim´ enez-Guerrero, P., Jorba, O., P´ erez, C., L´ opez, E., ¨ Uereca, P., Mart´ ın, F., Vivanco, M. G., Palomino, I., Querol, X., Pandolfi, M., and M. J., and Di´ eguez, J. J.: Caliope: an operational air quality forecasting system for the Iberian Peninsula, Balearic Islands and Canary Islands – first annual evaluation and ongoing developments, Adv. Sci. Res., 2, 89–98, 2008a.25 Baldasano, J. M., G¨ uereca, L. P., Lopez, E., Gass´ o, S., and Jim´ enez-Guerrero, P.: Development of a high-resolution (1 km×1 km, 1h) emission model for Spain: The High-Elective Resolution Modeling Emission System (HERMES), Atmos. Environ., 42(31), 7215–7233, 2008b. Baldasano, J. M., Pay, M. T., Jorba, O., Piot, M., and Jim´ enez, P.: An annual assessment of air quality with the CALIOPE modeling system over Spain, Sci. Total Environ., accepted, 2010.30 362 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Binkowski, F. S.: Aerosols in models-3 CMAQ, in: Science Algorithms of the EPA Models- 3 Community Multiscale Air Quality (CMAQ), edited by: Byun, D. W. and Ching, J. K. S., Modeling System, EPA, 10–23, 1999. Binkowski, F. S. and Roselle, S. J.: Models-3 Community Multiscale Air Quality (CMAQ) model aerosol component 1. Model description, J. Geophys. Res., 108(D6) 4183,5 doi:10.1029/2001JD001409, 2003. Borrego, C., Tchepel, O., Costa, A. M., Amorim, J. H., and Miranda, A. I.: Emission and dispersion modeling of Lisbon air quality at local scale, Atmos. Environ., 37, 5197–5205, doi:10.1016/j.atmosenv.2003.09.004, 2003. Borrego, C., Monteiro, A., Ferreira J., Miranda, A. I., Costa, A. M., Carvalho, A. C., and Lopes,10 M.: Procedures for estimation of modeling uncertainty in air quality assessment, Environ. Int., 34(5), 613–20, doi:10.1016/j.envint.2007.12.005, 2008. Brauer M. and Brook, J. R.: Ozone personal exposures and health effects for selected groups residing in the Freser Valley, Atmos. Environ., 31(14), 2113–2121, 1997. Byun, D. W. and Ching, J. K. S.: Science Algorithms of the EPA Models-3 Community Multi-15 scale Air Quality (CMAQ) Modeling System. EPA/600/R-99/030, US EPA, National Exposure Research Laboratory, Research Triangle Park, NC, 1999. Byun, D. W. and Schere, K. L.: Review of the governing equations, computational algorithms, and other components of the Models-3 Community Multiscale Air Quality (CMAQ) modeling system, Appl. Mech. Rev., 59, 51–77, 2006.20 Carter, W. P. L.: Implementation of the SAPRC-99 Chemical Mechanism into the Models-3 Framework, Report to the United States Environmental Protection Agency, 29 January, available at: http://www.cert.ucr.edu/∼carter/absts.htm#s99mod3, 2000. Chang, J. C. and Hanna, S. R.: Air quality model performance evaluation, Meteorol. Atmos. Phys., 87, 167–196, doi:10.1007/s00703-003-0070-7, 2004.25 Chemel, C., Sokhi, R., Yu, Y., Hayman, G., Vincent, K., Dore, A. J., Tang, Y., Prain, H., and Fisher, B.: Evaluation of a CMAQ simulation at high resolution over the UK for the calendar year 2003, Atmos. Environ., 44, 24, 2927–2939, doi:10.1016/j.atmosenv.2010.03.029, 2010. Cristofanelli, P. and Bonasoni, P.: Background Ozone in the southern Europe and Mediterranean area: Influence of the transport processes, Environ. Pollut., 157, 5, 1399–1406,30 doi:10.1016/j.envpol.2008.09.017, 2009. Delle Monache, L., Nipen, T., Deng, X., Zhou, Y., and Stull, R.: Ozone ensemble forecasts: 2. A Kalman filter predictor bias correction, J. Geophys. Res., 111, D05308, 363 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | doi:10.1029/2005JD006311, 2006. Delle Monache, L., Wilczak, J., Mckeen, S., Grell, G., Pagowski, M., Peckham, S., Stull, R., McHenry, J., and McQueen, J.: A Kalman-filter bias correction method applied to deterministic, ensemble averaged, and probabilistic forecasts of surface ozone, Tellus Ser. B, 60, 238–249, doi:10.1111/j.1600-0889.2007.00332.x, 2008.5 Denby, B., Georgieva, E., Larssen, S., Guerreiro, C., Li, L., Douros, J., Moussiopoulos, N., Fragkou, L., Gauss, M., Olesen, H., Miranda, A. I., Dilara, P., Thunis, P., Sari, L., Rouil, L., L¨ ukewille, A., Querol, X., Martin, F., Schaap, M., Van den Hout, D., Kobe, A., Silibello, C., Vincent, K., Stedman, J., Gonc¸alves, M., Pirovano, G., Volta, L., Van Pul, A., Gonz´ alez Ortiz, A., Roberts P., and Oettl, D.: Guidance on the use of models for the European Air Quality10 Directive. A working document of the Forum for Air Quality Modeling in Europe FAIRMODE, Technical Report Version 6.1, edited by: B. Denby, 1–99, 2010. Dennis, R., Fox, T., Fuentes, M., Gilliland, A., Hanna, S., Hogrefe, C., Irwin, J., Rao, S. T., Scheffe, R., Schere, K., Steyn, D., and Venkatram, D.: A framework for evaluating regional-scale numerical photochemical modeling systems, Environ. Fluid Mech.,15 doi:10.1007/s10652-009-9163-2, 2010. Eder, B., Kang, D., Mathur, R., Yu, S., and Schere, K.: An operational evaluation of the Eta-CMAQ air quality forecast model, Atmos. Environ., 40, 4894–4905, doi:10.1016/j.atmosenv.2005.12.062, 2006. European Commission: Directive 2008/50/EC of the European Parliament and of the Council of20 21 May 2008 on ambient air quality and cleaner air for Europe, Technical Report 2008/50/EC, L152, Off. J. Eur. Comm, 2008. Finlayson-Pitts, B. J.: Atmospheric Chemistry, PNAS, 107(15), 6566–6567, 2010. Flemming, J. and Stern, R.: Testing model accuracy measures according to the EU directivesexamples using the chemical transport model REM-CALGRID, Atmos. Environ., 41, 9206–25 9216, doi:10.1016/j.atmosenv.2007.07.050, 2007. Folberth, G. A., Hauglustaine, D. A., Lathi` ere, J., and Brocheton, F.: Interactive chemistry in the Laboratoire de M´ et´ eorologie Dynamique general circulation model: model description and impact analysis of biogenic hydrocarbons on tropospheric chemistry, Atmos. Chem. Phys., 6, 2273–2319, doi:10.5194/acp-6-2273-2006, 2006.30 Gangoiti, G., Mill´ an, M. M., Salvador, R., and Mantilla, E.: Long-range transport and recirculation of pollutants in the western Mediterranean during the project Regional Cycles of Air Pollution in the West-Central Mediterranean Area, Atmos. Environ., 35, 6267–6276, 364 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | 2001. Garber, W., Colosio, J., Grittner, S., Larssen, S., Rasse, D., Schneider, J., and Housiau, M.: Guidance on the Annexes to Decision 97/101/EC on Exchange of Information as revised by Decision 2001/752/EC, Technical Report, European Commission, DG Environment 1–71, 2002.5 Gerasopoulos, E., Kouvarakis, G., Vrekoussis, M., Kanakidou, M., and Mihalopoulos, N.: Ozone variability in the marine boundary layer of the eastern Mediterranean based on 7- year observations, J. Geophys. Res., 110, D15309, doi:10.1029/2005JD005991, 2005. Gery, M., Whitten, G., Killus, J., and Dodge, M.: A Photochemical Kinetics Mechanism for Urban and Regional Scale Computer Modeling, J. Geophys. Res., 94(D10), 12925–12956,10 1989. Gonc¸alves, M., Jim´ enez-Guerrero, P., and Baldasano, J. M.: Contribution of atmospheric processes affecting the dynamics of air pollution in South-Western Europe during a typical summertime photochemical episode, Atmos. Chem. Phys., 9, 849–864, doi:10.5194/acp-9-849- 2009, 2009.15 Guenther, A. B., Hewitt, C. N., Erickson, D., Fall, R., Geron, C., Graedel, T., Harley, P., Klinger, L., Lerdau, M., McKay, W. A., Pierce, T., Scholes, B., Steinbrecher, R., Tallamraju, R., Taylor, J., and Zimmerman, P.: A global model of natural volatile organic compound emissions, J. Geophys. Res., 100, 8873–8892, 1995. Hauglustaine, D. A, Hourdin, F., Jourdain, L., Filiberti, M. A., Walters, S., Lamarque, J. F.,20 and Holland, E. A.: Interactive chemistry in the Laboratoire de Meteorologie Dynamique general circulation model: Description and background tropospheric chemistry evaluation, J. Geophys. Res., 109, 1–44, 2004. Hies, T., Treffeisen, R., Sebald, L., and Reimer, E.: Spectral analysis of air pollutants. Part 1: elemental carbon time series, Atmos. Environ., 34, 21, 3495–3502, 2000.25 Janjic, Z. I.: The step-mountain ETA coordinate model: Further developments of the convection, viscous sublayer and turbulence closure schemes, Mon. Weather Rev., 122, 927–945, 1994. Jim´ enez, P. and Baldasano, J. M.: Ozone response to precursor controls in very complex terrains: Use of photochemical indicators to assess O3-NOx-VOC sensitivity in the northeastern Iberian Peninsula, J. Geophys. Res., 109, D20309, doi:10.1029/2004JD004985, 2004.30 Jim´ enez, P., Parra, R., Gass´ o, S., and Baldasano, J. M.: Modeling the ozone weekend effect in very complex terrains: a case study in the northeastern Iberian Peninsula, Atmos. Environ., 39, 429–444, 2005a. 365 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Jim´ enez, P., Jorba, O., Parra, R., and Baldasano, J. M.: Influence of high-model grid resolution on photochemical modeling in very complex terrains, Int. J. Environ. Pollut., 24, 180–200, 2005b. Jim´ enez, P., Lelieveld, J., and Baldasano, J. M.: Multi-scale modeling of air pollutants Dynamics in the North-Western Mediterranean Basin during a typical summertime episode, J.5 Geophys. Res., 111, D18306, doi:10.1029/2005JD006516, 2006. Jim´ enez, P., Jorba, O., Baldasano, J. M., and Gass´ o, S.: The Use of a Modeling System as a Tool for Air Quality Management: Annual High-Resolution Simulations and Evaluation, Sci. Tot. Env., 390, 323–340. doi:10.1016/j.scitotenv.2007.10.025, 2008. Kalman, R. E.: A new approach to linear filtering and prediction problems, J. Basic Eng., 82,10 35–45, 1960. Kang, D., Eder, B. K., Stein, A. F., Grell, G. A., Peckham, S. E., and McHenry, J.: The New England air quality forecasting pilot program: Development of an evaluation protocol and performance benchmark, J. Air Waste Manage. Assoc., 55, 1782–1796, 2005 Kang, D., Mathur, R., Rao, S. T., and Yu, S.: Bias adjustment techniques for improving ozone15 air quality forecasts, J. Geophys. Res., 113, D23308, doi:10.1029/2008JD010151, 2008. Kang, D., Mathur, R., and Trivikrama Rao, S.: Assessment of bias-adjusted PM2.5 air quality forecasts over the continental United States during 2007, Geosci. Model Dev., 3, 309–320, doi:10.5194/gmd-3-309-2010, 2010. Lam, Y. F. and Fu, J. S.: A novel downscaling technique for the linkage of global and regional air20 quality modeling, Atmos. Chem. Phys., 9, 9169–9185, doi:10.5194/acp-9-9169-2009, 2009. Marr, L. C. and Harley, R. A.: Spectral analysis of weekday–weekend differences in ambient ozone, nitrogen oxide, and non-methane hydrocarbon time series in California, Atmos. Environ., 36, 14, 2327–2335, doi:10.1016/S1352-2310(02)00188-7, 2002. Michalakes, J., Dudhia, J., Gill, D., Henderson, T., Klemp, J., Skamarock, W., and Wang, W.:25 The weather research and forecast model, in: Software architecture and performance, edited by: Mozdzynski, E. G., Proceeding of the Eleventh ECMWF Workshop on the Use of High Performance Computing in Meteorology, 2529, Reading, UK, 117–124, 2004. Mill´ an, M., Salvador, R., and Mantilla, E.: Photooxidant dynamics in the Mediterranean basin in summer: Results from European research projects, J. Geophys. Res., 102(D7), 8811–8823,30 1997. Mill´ an, M., Sanz, M. J., Salvador, R., and Mantilla, E.: Atmospheric dynamics and ozone cycles related to nitrogen deposition in the western Mediterranean, Environ. Pollut., 118(2), 167–86, 366 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | 2002. Nenes, A., Pandis, S. N., and Pilinis, C.: SORROPIA: A New Thermodynamic Equilibrium Model for Multiphase Multicomponent Inorganic Aerosols, Aquat. Geochem., 4, 123–152, 1998. Nickovic, S., Kallos, G., Papadopoulos, A., and Kakaliagou, O.: model for prediction5 of desert dust cycle in the atmosphere, J Geophys. Res., 106(D16), 18113–18129, doi:10.1029/2000JD900794, 2001. Parra, R., Gass´ o, S., and Baldasano, J. M.: Estimating the biogenic emissions of non-methane volatile organic compounds from the North Western Mediterranean vegetation of Catalonia, Spain, Sci. Tot.Env., 29, 241–259, 2004.10 Parra, R., Jim´ enez, P., and Baldasano, J. M.: Development of the high spatial resolution EMICAT2000 emission model for air pollutants from the north–eastern Iberian Peninsula (Catalonia, Spain), Environ. Pollut, 140, 200–219, 2006. Pay, M. T., Piot, M., Jorba, O., Gass´ o, S., Gonc¸alves, M., Basart, S., Dabdub, D., Jim´ enez, P., and Baldasano, J. M.: A full year evaluation of the CALIOPE-EU air quality modeling system15 over Europe for 2004, Atmos. Environ., 44, 3322–3342 doi:10.1016/j.atmosenv.2010.05.040, 2010. P´ erez, C., Nickovic, S., Baldasano, J. M., Sicard, M., Rocadenbosch, F., and Cachorro, V. E.: A long Saharan dust event over the western Mediterranean: Lidar, sun photometer observations, and regional dust modeling, J. Geophys. Res., 111, D15214,20 doi:10.1029/2005JD006579, 2006a. P´ erez, C., Nickovic, S., Pejanovic, G., Baldasano, J. M., and Ozsoy, E.: Interactive dustradiation modeling: A step to improve weather forecasts, J. Geophys. Res., 111, D16206, doi:10.1029/2005JD006717, 2006b. Proyecto De Real Decreto Relativo A La Mejora De La Calidad Del Aire Ministerio De Medio25 Ambiente: ´ Area de Calidad del Aire Subdirecci´ on General de Calidad del Aire y Medio Ambiente Industrial Ministerio de Medio Ambiente y Medio Rural y Marino, 2010. Sebald, L., Treffeisen, R., Reimer, E., and Hies, T.: Spectral analysis of air pollutants. Part 2: ozone time series, Atmos. Environ., 34, 21, 3503–3509, 2000. Skamarock, W. C., Klemp, J. B., Dudhia, J., Gill, D. O., Barker, D. M., Wang, W., and Powers, J.30 G.,: A Description of the Advanced Research WRF Version 2 NCAR Tech Notes-468, 2005. Skamarock, W. C. and Klemp, J. B.: A time-split nonhydrostatic atmospheric model for weather research and forecasting applications, J. Comput. Phys., 227(7), 3465–3485, 367 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Fig. 1. RedESP stations network measuring ozone concentration in Spain. Different types of stations (U: Urban; S: Suburban; R: Rural; B: Background; I: Industrial; and T: Traffic) are represented by symbols and color codes. 374 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Fig. 2. Seasonal ratio sensitivity for the hourly O3concentrations over the 82 RedESP stations. Left Panel: Root Mean Square Error and Right Panel: Correlation. Values are computed with the ratio raging from 0.01 to 2, plotted on logarithmic scale. Perfect RMSE would be 0, and perfect correlation coefficient 1. On the plots are reported RMSE and COR before the application of the Kalman Filter. 375 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Fig. 3. Time series of the max. 1-h ((left panel) and max. 8-h (right panel) ground level O3concentration (µg m−3), averaged for all RedESP stations for the model results and the KF-output, for the year 2004. The plot of the biases (µg m−3) is also included. 376 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Fig. 4. Spatial distribution of correlation (COR, ideal value would be 1), Mean Bias (MB, µg m−3), Root Mean Square Error (RMSE, µg m−3) and Standard Deviation of the error (SDer) for the max. 1-h, for all the RedESP stations, averaged over the year 2004. The air quality monitoring stations are represented according to their type: urban (dots), suburban (triangle), and rural (square). 377 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Fig. 4. Continued. 378 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Fig. 5. Spatial distribution of Correlation (COR, ideal value would be 1), Mean Bias (MB, µg m−3), Root Mean Square Error (RMSE, µg m−3) and Standard Deviation of the error (SDer) for the max. 8-h, for all the RedESP stations, averaged over the year 2004. The air quality monitoring stations are represented according to their type: urban (dot), suburban (triangle), and rural (square). 379 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Fig. 5. Continued. 380 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Fig. 6. Taylor Diagrams for the max. 1-h and max. 8-h. All the considered stations are plotted. The different symbols represent the types of stations. On the plots are depicted the Standard Deviation (µg m−3) of the simulated maximum O3concentration (radius) and the Correlations (cosine of the angle to the horizontal axis). On the horizontal axis is located the standard deviation of the observed values, the closest are the points to this value, the better are simulated the values. The statistics are calculated over the year 2004. 381 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Fig. 7. Predicted versus Observed max. 1-h and max. 8-h O3for the year 2004 for all the stations considered. The plotted values are on hourly bases. On the plots are depicted the threshold limit 120 µg m−3and 180 µg m−3as established by the EU for the max. 1-h and max. 8-h respectively. The letters a,b,c,drepresent the exceedances that did occur (hits), the exceedances that did not occur (false alarms), the exceedances that were not predicted but observed (misses), and the exceedances that did not occur and were not predicted respectively (correct negatives), see Sect. 4.2. 382 GMDD 4, 343–384, 2011 Ground-level ozone concentration over Spain V. Sicardi et al. Title Page Abstract Introduction Conclusions References Tables Figures J I J I Back Close Full Screen / Esc Printer-friendly Version Interactive Discussion Discussion Paper | Discussion Paper | Discussion Paper | Discussion Paper | Fig. 8. Spectral analysis of daily O3concentrations averaged for the whole year averaged over all the stations. The spectral power of the observations (red), model results (blue) and KF-output (bright blue) are compared. The axes are on logarithmic scale. 383