scieee AI-readable full text Open interactive document viewer

Promoting laccase sensing activity for catechol detection using LBL assemblies of chitosan/ionic liquid/phthalocyanine as immobilization surfaces

Salvo Comino, Coral,García Hernández, Celia,García Cabezón, Ana Cristina,Rodríguez Méndez, María Luz

Abstract

Producción Científica

Full text

1 PROMOTING LACCASE SENSING ACTIVITY FOR CATECHOL DETECTION USING LBL ASSEMBLIES OF CHITOSAN/IONIC LIQUID/ PHTHALOCYANINE AS IMMOBILIZATION SURFACES C. Salvo-Cominoa,c, C. Garcia-Hernandeza,c, C. Garcia-Cabezonb,c, M.L. Rodriguez- Mendeza,c,* aGroup UVASens. Engineers School, Universidad de Valladolid, 47011 Valladolid (Spain). bGroup UVASens. Materials Science Department, Universidad de Valladolid, 47011 Valladolid (Spain). cBioecoUVA Research Institute, Engineers School, Universidad de Valladolid, 47011 Valladolid (Spain). E-mails: [email protected], [email protected], [email protected], [email protected] *Corresponding Author: Prof. María Luz Rodríguez-Méndez, Group UVASens, Escuela de Ingenierías Industriales, Paseo del Cauce, 59, 47011 Valladolid. Spain. Phone: +34 983 423540; FAX: +34 983 423310; e-mail: [email protected] 'Declarations of interest: none'. © 2020 Elsevier. This manuscript version is made available under the CC-BY-NC-ND 4.0 https://doi.org/10.1016/j.bioelechem.2019.107407 2 ABSTRACT The performance of electrochemical laccase-based biosensors can be improved by immobilizing the enzyme on composite Layer-by-Layer (LbL) supports in which materials with complementary functions are combined. LbL films are formed by layers combining an electrocatalytic material which favors electron transfer (sulfonated copper phthalocyanine, CuPcS(-)), an ionic liquid which enhances the electrical conductivity of the layers (1-butyl-3-methylimidazolium tetrafluoroborate, IL(+)) and a material able to promote enzyme immobilization (chitosan, CHI(+)). Composite films with different structures have been demonstrated to be efficient electrocatalysts, producing an increase in the magnitude of the responses towards catechol. The most intense and reproducible electrocatalytic effect was observed when a layer of the CuPcS(-) was placed on top of a layer formed by a mixture of CHI(+)+IL(+) to obtain [CHI(+)+IL(+)|CuPcS(-)]2 films. Biosensors with laccase immobilized on the surface of the LbL layers [CHI(+)+IL(+)|CuPcS(-)]2|Lac showed mediated electron transfer between the redox enzyme and the film and a reproducibility of device-to-device performance of 4.1%. The amperometric biosensor showed a sensitivity of 0.237 A·M−1 and a linear detection range from 2.4 μM to 26 μM for catechol. The excellent Limit of detection (LOD) of 8.96·10-10 M (3·σ /m) is one order of magnitude lower than that obtained in similar studies. A Michaelis-Menten constant of 3.16 μM confirms excellent enzyme-substrate affinity. Keywords: Layer-by-Layer; Laccase; biosensor; catechol; phthalocyanine 3 1. INTRODUCTION Catechol is a widely studied phenol that occurs naturally in foods and vegetables and is also a common industrial byproduct [1]. A wide range of electrochemical sensors and biosensors dedicated to the detection of phenols have been developed [2,3]. This assortment is due to the number of immobilization procedures aimed at improving enzyme functionality. These include: entrapment in sol–gel or hydrogel matrices; incorporation into polymer films; covalent linking to the electrode surface; or immobilization on self-assembled monolayers, Langmuir- Blodgett films or the surface of carbon nanotubes; among many others [4–6]. In addition, different electron mediators have been used to facilitate electron transfer between the enzyme and the electrode. These include Prussian blue [7], conducting polymers [4,8,9], nanoparticles [10] or graphene [11,12], among others. The Layer by layer (LbL) technique is an interesting approach for the preparation of enzymatic biosensors, as it provides structures which can be a suitable support for enzyme immobilization [13–15]. In previous studies, LbL films combining polyethyleneimine (PEI) [13,16], polyallylamine hydrochlorate (PAH) [14,17], or chitosan (CHI) -as positively charged specieswith poly(styrene sulfonate) (PSS) or polyvinyl sulfonate (PVS) -as polyanionshave been used as substrates for biosensors [18,19]. The objective of the present study was to explore a new strategy to improve the performance of biosensors using LbL assemblies with a dual functionality. In this approach, LbL films act simultaneously as suitable supports for enzyme immobilization and as efficient electron mediator layers. An enzymatic electrochemical biosensor for catechol detection was developed for this purpose, in which a phenol oxidase (laccase) was immobilized on LbL films prepared with materials selected to preserve and promote enzyme activity and to facilitate electron transfer. The materials chosen included CHI(+), a natural cationic polyaminosaccharide, which was selected as a cationic polymer since it is a standard support for enzyme immobilization [20–25]. The selection of CuPcS(-) was due to its electrocatalytic and film forming properties [4,14,26,27]. A variety of metallophthalocyanines have been used as redox mediators for enzyme based sensor phthalocyanines [28–31]. However, phthalocyanines have the inconvenience of their low conductivity [32]. To improve the conductivity of the sensing layer, an IL(+) was included in the LbL assembly, owing to its high ionic conductivity and electrochemical stability [33–36]. In short, in this work, LbL films combining positively charged molecules including CHI(+) and IL(+) and a polyanion, CuPcS(-) were designed. The benefits obtained by the immobilization properties provided by CHI(+), the electrocatalytic activity of CuPcS(-), the high ionic conductivity of the IL(+) and the occurrence of synergetic effects due to interaction between the components were explored. The influence of the architecture of the LbL films in the immobilization of Laccase and on the electron transfer from the enzyme to the electrode were analyzed. Performance of the biosensor was investigated in terms of sensitivity, linearity range, limits of detection and reproducibility. 2. MATERIALS AND METHODS 2.1. Materials and Instruments Chitosan (CHI(+)) (medium molecular weight, 75-85% deacetylated chitin) (CAS Number: 9012-76-4), copper (II) phthalocyanine-3,4´,4´´,4´´´-tetrasulfonic acid tetrasodium salt (CuPcS(-)), and 1-butyl-3-methyliimidazolium tetrafluoroborate (IL(+)) were purchased from Sigma-Aldrich (St. Louis, MO, USA). Laccase enzyme (Lac, from Trametes versicolor, activity of 10 U mg-1, CAS 80498-15-3) and catechol were also 4 5 purchased from Sigma-Aldrich. Glutaraldehyde (50% aqueous solution) was purchased from Alfa Aesar (Haverhill, MA, USA). Deionized water from MilliQ (resistivity 18.2 MΩ·cm) was used in all solutions and experiments. Layer by layer films were prepared using a rotary dip-coater device ND-R from Nadetech (Spain). LbL films were deposited onto different substrates including glass, ZnS, quartz, mica and ITO glass. ITO glass slides were purchased from SIGMA (surface resistivity 15-25 Ω/sq). Mica slides were muscovite Mica V2 quality (Electron Microscopy Science. USA.Cat . 71857-01-10). UV-Vis characterization was performed using films deposited on quartz substrates in a Shimadzu UV-2600. Fourier Transform Infrared (FTIR) spectra of films deposited on ZnS were obtained using a FTIR 6600 Jasco spectrophotometer from 700 to 2000 cm−1, at a resolution of 4 cm-1 and 1000 scans. Atomic force microscope (AFM) images were recorded in films deposited on mica at room temperature in a NanoScope IIIa operated in tapping mode. Electrochemical measurements were carried out using a potentiostat/galvanostat PGSTAT128 (Autolab Metrohm, Utrecht, Netherlands). 2.2. Sensor preparation Substrates were modified with LbL films containing CHI(+),CuPcS(-)and IL(+). Films with two different preparation sequences were developed. The first sequence was denoted as [CHI(+)|CuPcS(-)|IL(+)|CuPcS(-)]n, where n means the number of repetitions. These films were prepared by incubating an ITO substrate in different solutions (at 21ºC and 30% relative humidity) using the following sequence: 1) Immersion in a CHI(+) solution (10-3 M, prepared in acetic acid 0.3% v/v) for 5 min. 2) Washing step by immersion in deionized water for 5 s. 3) Immersion in an aqueous solution of CuPcS(-) (5·10-5 M) for 5 min. 4) Washing step in deionized water for 5 s. 5) Immersion in a 10-3 M solution of IL(+) during 5 min. 6) Washing in deionized water for 6 5 s. 7) Immersion in an aqueous solution of CuPcS(-) (5·10-5 M) for 5 min. 8) Washing in deionized water for 5 s. This procedure was repeated to increase the thickness of the structures. The second architecture was obtained by alternating immersions in a solution containing a mixture of positively charged materials (CHI(+)+IL(+)) (1:1 v/v) and a solution of the negative CuPcS(-) to form [CHI(+)+IL(+)|CuPcS(-)]n . The procedure was as follows: 1) Immersion in a mixture (CHI(+)+IL(+)) (1:1 v/v) for 5 min. 2) Washing with deionized water for 5 s. 3) Immersion in CuPcS(-) (5·10-5 M) for 5 min. 4) Washing with deionized water for 5 s. Biosensors were prepared by depositing the enzyme laccase (Lac) on the surface of the LbL films using the following method. After washing the LbL films in 0.01 M phosphate buffer (pH 7.00) for 2 min and subsequent drying, 50 µL of a solution containing 5 mg·mL-1 of the enzyme (in a 0.01 M phosphate buffer; pH 7.00) were deposited onto the surface. Once dried at room temperature, the enzyme was cross-linked by introducing the device into a desiccator (20 cm diameter) containing 20 ml of a 2.5% (v/v) glutaraldehyde solution prepared in 0.01 M phosphate buffer during 20 min at room temperature. Sensors were washed in order to remove any unbound enzyme from the electrode surface. 2.3. Electrochemical measurements Electrochemical experiments were carried out in a three-electrode electrochemical cell (50 mL) using the LbL films deposited on ITO glass as the working electrode. Ag| AgCl (3M)/KCl (0.1M) was used as the reference electrode and a platinum sheet (2 cm2) as the counter electrode. Cycles were carried out from -800 to 1200 mV at a scan rate of 100 mV·s-1 in 10-4M catechol in 0.01 M phosphate buffer (pH 7.00). Experiments 7 focused on studying of the effect of the scan rate were carried out from 10 to 1000 mV·s-1. Chronoamperometry was carried out at a fixed potential of -200 mV. 3. RESULTS AND DISCUSSION 3.1. Preparation and structural characterization of LbL films Films formed by the combination of CHI(+), IL(+) and CuPcS(-) were deposited using the LbL technique. These films were used as substrates for enzyme immobilization and to promote electron transfer. Two types of structures were prepared: LbL films where cationic species were deposited in successive steps [CHI(+)|CuPcS(-)|IL(+)| CuPcS(-)]n and films where cations were mixed and deposited in a single step [CHI(+) +IL(+)|CuPcS(-)]n. The deposition of the layers was monitored by UV-vis spectroscopy (Figure 1.a). Spectra registered on quartz substrates were similar for all the films obtained, independently of their architecture. They showed the classical strong Q band at 680 nm, originated by a ∗π−π transition at the phthalocyanine ring. The Q band showed a shoulder at 617 nm associated to the presence of H-aggregates due to the formation of dimeric species [37,38]. Spectra also showed a band at ~335 nm produced by a ∗π−π transition named the Soret band [39]. As observed in Figure 1.b, absorbance values measured at 680 nm increased linearly with the number of layers (correlation coefficient higher than 0.9906 in all structures tested), confirming the formation of the layers on the surface of the substrate. Once LbL films had been obtained, Laccase was immobilized on the surface. UV-vis spectra of the [CHI(+)|CuPcS(-)|IL(+)|CuPcS(-)]2 substrate and the [CHI(+)|CuPcS(-)|IL(+)|CuPcS(-)]2|Lac biosensor are shown in Figure 1.c. The spectrum of the biosensor showed the characteristic bands of the LbL films and the typical band at 280 nm produced by the presence of the enzyme. Spectral data of [CHI(+)+IL(+)| CuPcS(-)|2 and [CHI(+)+IL(+)|CuPcS(-)|2|Lac are shown in Figure S.1, confirming the formation of the films on the surface of the substrate, independently of the sensor architecture. 8 “Here Figure 1” FTIR spectra of the LbL films, deposited on a zinc sulfide (ZnS) substrate, showed the characteristics bands of all three compounds forming the layers (Figure 2.a)[22,40– 42]. In addition, FTIR spectra were identical, regardless of the structure of the LbL films as can be seen in Figure S.2. The peaks of the [CHI(+)+IL(+)|CuPcS(-)]n sensor and casted films of the individual components are collected in Table 1. The characteristic peaks of CHI (+) appeared at 3424 cm -1, corresponding to the OH stretching vibrations; at 1657 cm-1, related to the C-O stretching; and at 1419 cm −1 and 1395 cm −1, due to the C-H-OH bending and CH 2OH stretching, respectively. Peaks produced by the IL(+) appeared at 1647 cm-1, corresponding to the C=C and C=N bonds [22,43,44]. Peaks characteristic of the CuPc S(-) appeared at 1456 cm-1 (asymmetric bending isoindole), 1338 cm -1 (pyrrole stretching of the –C=C–N– bonds) [45–47], 1093 cm-1 produced by the in-plane C-H bending, 1027 cm -1 related to the isoindole deformation and aza stretching [46], and 742 cm-1 due to C-H bending [46,48]. Transmittance increased linearly with the number of layers, with regression coefficients close to 1 (for instance, the R2 of the peak at 1027cm-1 was 0.9627). Similar coefficients were obtained for films with different architectures. The FTIR spectra of the biosensors were also registered. As expected, these spectra showed the typical amide bands of the polyphenol oxidase, which appeared at 1625 cm-1 and 1567 cm-1 (Figure 2.b). The band assignment confirmed the correct adsorption of the enzyme onto the surface of the LbL films [49]. “Here Figure 2” “Here Table 1” AFM images of the surface of films with different architectures and increasing number of layers were registered and compared (Figure 3). In all cases, the images showed smooth surfaces that increased their roughness when the number of layers were increased. The RMS of [CHI(+)+IL(+)|CuPcS(-)]2 (where both cationic species were mixed and deposited in the same step) was 0.39 nm and increased to 7.71 nm in thicker films formed by 12 bilayers [CHI(+)+IL(+)|CuPcS(-)]12. In LbL films where each cation was deposited in a different step, the RMS increased from 0.46 nm in [CHI(+)|CuPcS(-)|IL(+)|CuPcS(-)]2 to 14.07 in [CHI(+)|CuPcS(-)|IL(+)|CuPcS(-)]12. The increase in the RMS points to the presence of aggregation and indicates that the molecular ordering of the LbL films decreased with the number of layers. It is also important to point out that the different components added in sequential steps probably interpenetrate. Figure 3.e shows the AFM image of the [CHI(+)+IL(+)|CuPcS(-)]2|Lac sensor. In the presence of the enzyme, globular structures were observed (138 nm height) on top of smooth surface (3 nm in height). These structures, with similar sizes, have been already observed in previously published results [8]. However, the presence of globules can be caused by the reorganization of the layer when laccase is deposited on top of the LbL film [50,51]. “Here Figure 3”3.2. Sensing properties of LbL films and biosensors based on LbL films The sensing properties for catechol of [CHI(+)+IL(+)|CuPcS(-)]n and [CHI(+)| CuPcS(-)|IL(+)|CuPcS(-)]n films were analyzed by cyclic voltammetry. Then, laccase was deposited on top of LbL films and the performance of the biosensors was analyzed. A bare ITO, immersed in catechol 10-4 M, showed one anodic wave at ~900 mV and one cathodic wave at ~-100 mV, corresponding to the oxidation and reduction of catechol, respectively. When the ITO was modified with the LbL films, the intensity of 9 16 6. REFERENCES [1] J.H. Tyman, Synthetic and Natural Phenols, First, Elsevier Science, 1996. [2] F. Karim A. N. M. Fakhruddin, Recent advances in the development of biosensor for phenol: a review, Rev Environ Sci Biotechnol 11 (2012) 261-274. doi: 10.1007/s11157-012-9268-9 [3] W. Jina, G. Maduraiveeran, Electrochemical detection of chemical pollutants based on gold nanomaterials, Trends Environ. Anal. 14 (2017) 28–36. doi: 10.1016/j.teac.2017.05.001 [4] P. Alessio, F.J. Pavinatto, O.N. Oliveira Jr, J.A. De Saja Saez, C.J.L. Constantino, M.L. Rodríguez-Méndez, Detection of catechol using mixed Langmuir–Blodgett films of a phospholipid and phthalocyanines as voltammetric sensors, Analyst. 135 (2010) 2591. doi:10.1039/c0an00159g. [5] F. Dridi, M. Marrakchi, M. Gargouri, J. Saulnier, N. Jaffrezic-Renault, F. Lagarde, Nanomaterial-based electrochemical biosensors for food safety and quality assessment. Nanobiosensors, pp.167-204. Elsevier: The Netherlands, 2017. doi:10.1016/B978-0-12-804301-1.00005-9. [6] W. Putzbach, N.J. Ronkainen, Immobilization techniques in the fabrication of nanomaterial-based electrochemical biosensors: A review, Sensors (Switzerland). 13 (2013) 4811–4840. doi:10.3390/s130404811. [7] T.M.B.F. Oliveira, M. Fátima Barroso, S. Morais, M. Araújo, C. Freire, P. de Lima-Neto, A.N. Correia, M.B.P.P. Oliveira, C. Delerue-Matos, Laccase- Prussian blue film-graphene doped carbon paste modified electrode for carbamate pesticides quantification, Biosens. Bioelectron. 47 (2013) 292–299. 17 doi:10.1016/j.bios.2013.03.026. [8] M. Nazari, S. Kashanian, R. Rafipour, Laccase immobilization on the electrode surface to design a biosensor for the detection of phenolic compound such as catechol, Spectrochim. Acta - Part A Mol. Biomol. Spectrosc. 145 (2015) 130– 138. doi:10.1016/j.saa.2015.01.126. [9] C. Apetrei, M.L. Rodríguez-Méndez, J.A. De Saja, Amperometric tyrosinase based biosensor using an electropolymerized phosphate-doped polypyrrole film as an immobilization support. Application for detection of phenolic compounds, Electrochim. Acta. 56 (2011) 8919–8925. doi:10.1016/j.electacta.2011.07.127. [10] Y. Zheng, D. Wang, Z. Li, X. Sun, T. Gao, G. Zhou, Laccase biosensor fabricated on flower–shaped yolk–shell SiO2nanospheres for catechol detection, Colloids Surfaces A Physicochem. Eng. Asp. 538 (2018) 202–209. doi:10.1016/j.colsurfa.2017.10.086. [11] Y.Q. Zhang, Y.J. Fan, L. Cheng, L.L. Fan, Z.Y. Wang, J.P. Zhong, L.N. Wu, X.C. Shen, Z.J. Shi, A novel glucose biosensor based on the immobilization of glucose oxidase on layer-by-layer assembly film of copper phthalocyanine functionalized graphene, Electrochim. Acta. 104 (2013) 178–184. doi:10.1016/j.electacta.2013.04.099. [12] M. Zhang, A. Halder, C. Hou, J. Ulstrup, Q. Chi, Free-standing and flexible graphene papers as disposable non-enzymatic electrochemical sensors, Bioelectrochemistry. 109 (2016) 87–94. doi:10.1016/j.bioelechem.2016.02.002. [13] R.A. de Sousa Luza, M.V.A. Martinsa, J.L. Magalhãesa, J.R. Siqueira Jr., V. Zucolottoc, O.N. Oliveira Jr., F.N. Crespilho, W.C da Silva. Supramolecular architectures in layer-by-layer films of single-walled carbon nanotubes, chitosan 18 and cobalt (II) phthalocyanine. Mat. Chem 130 (2011) 1072-1077. doi: 10.1016/j.matchemphys.2011.08.038 [14] P. Alessio, C.S. Martin, J.A. De Saja, M.L. Rodriguez-Mendez, Mimetic biosensors composed by layer-by-layer films of phospholipid, phthalocyanine and silver nanoparticles to polyphenol detection, Sensors Actuators, B Chem. 233 (2016) 654–666. doi:10.1016/j.snb.2016.04.139. [15] J.R. Siqueira, Jr., L.H.S. Gasparotto, F.N. Crespilho, A.J.F. Carvalho,V. Zucolotto, O.N. Oliveira, Jr. Physicochemical Properties and Sensing Ability of Metallophthalocyanines/Chitosan Nanocomposites. J. Phys. Chem. B 110 (2006) 22690-22694. doi: 10.1021/jp0649089. [16] J.S. Graça, R.F. de Oliveira, M.L. de Moraes, M. Ferreira, Amperometric glucose biosensor based on layer-by-layer films of microperoxidase-11 and liposomeencapsulated glucose oxidase, Bioelectrochemistry. 96 (2014) 37–42. doi:10.1016/j.bioelechem.2014.01.001. [17] E.G.R. Fernandes, L.C. Brazaca, M.L. Rodríguez-Mendez, J.A. de Saja, V. Zucolotto, Immobilization of lutetium bisphthalocyanine in nanostructured biomimetic sensors using the LbL technique for phenol detection, Biosens. Bioelectron. 26 (2011) 4715–4719. doi:10.1016/j.bios.2011.05.032. [18] F.N. Crespilho, M.E. Ghica, V. Zucolotto, F.C. Nart, O.N. Oliveira, C.M.A. Brett, Electroactive nanostructured membranes (ENM): Synthesis and electrochemical properties of redox mediator-modified gold nanoparticles using a dendrimer layer-by-layer approach, Electroanalysis. 19 (2007) 805–812. doi:10.1002/elan.200603775. [19] E. Aynaci, A. Yaşar, F. Arslan, An amperometric biosensor for acetylcholine 19 determination prepared from acetylcholinesterase-choline oxidase immobilized in polypyrrolepolyvinylsulpfonate film, Sensors Actuators, B Chem. 202 (2014) 1028–1036. doi:10.1016/j.snb.2014.06.049. [20] Y. Tan, W. Deng, C. Chen, Q. Xie, L. Lei, Y. Li, Z. Fang, M. Ma, J. Chen, S. Yao, Immobilization of enzymes at high load/activity by aqueous electrodeposition of enzyme-tethered chitosan for highly sensitive amperometric biosensing, Biosens. Bioelectron. 25 (2010) 2644–2650. doi:10.1016/j.bios.2010.04.040. [21] X. Lu, J. Hu, X. Yao, Z. Wang, J. Li, Composite system based on chitosan and room-temperature ionic liquid: Direct electrochemistry and electrocatalysis of hemoglobin, Biomacromolecules. 7 (2006) 975–980. doi:10.1021/bm050933t. [22] S. Yasmeen, M. Kabiraz, B. Saha, M. Qadir, M. Gafur, S. Masum, Chromium (VI) Ions Removal from Tannery Effluent using Chitosan-Microcrystalline Cellulose Composite as Adsorbent, Int. Res. J. Pure Appl. Chem. 10 (2016) 1–14. doi:10.9734/IRJPAC/2016/23315. [23] R.D. Koyani, R. Vazquez-Duhalt, Laccase encapsulation in chitosan nanoparticles enhances the protein stability against microbial degradation, Environ. Sci. Pollut. Res. 23 (2016) 18850–18857. doi:10.1007/s11356-016- 7072-8. [24] H. Cabana, A. Ahamed, R. Leduc, Conjugation of Laccase from the white rot fungus Trametes versicolor to chitosan and its utilization for the elimination of triclosan, Bioresour. Technol. 102 (2011) 1656–1662. doi:10.1016/j.biortech.2010.09.080. [25] L. Yang, H. Xiong, X. Zhang, S. Wang, A novel tyrosinase biosensor based on 20 chitosan-carbon-coated nickel nanocomposite film, Bioelectrochemistry. 84 (2012) 44–48. doi:10.1016/j.bioelechem.2011.11.001. [26] S. Chaiyo, E. Mehmeti, W. Siangproh, T.L. Hoang, H.P. Nguyen, O. Chailapakul, K. Kalcher, Non-enzymatic electrochemical detection of glucose with a disposable paper-based sensor using a cobalt phthalocyanine–ionic liquid– graphene composite, Biosens. Bioelectron. 102 (2018) 113–120. doi:10.1016/j.bios.2017.11.015. [27] I. Zahou, R. Mlika, H. BenOuada, R. BenChaabane, N. Jaffrezic-Renault, Studies on the electrochemical properties of nickel phtalocyanine for impedimetric detection of environment pollutants: hydroquinone and bisphenol A, IET Sci. Meas. Technol. 9 (2015) 315–321. doi:10.1049/iet-smt.2014.0027. [28] R. Gonzalez-Anton, M.M. Osipova, C. Garcia-Hernandez, T. V. Dubinina, L.G. Tomilova, C. Garcia-Cabezon, M.L. Rodriguez-Mendez, Subphthalocyanines as electron mediators in biosensors based on phenol oxidases: Application to the analysis of red wines, Electrochim. Acta. 255 (2017) 239–247. doi:10.1016/j.electacta.2017.09.168. [29] R. Devasenathipathy, C. Karuppiah, S.-M. Chen, S. Palanisamy, B.-S. Lou, M.A. Ali, F.M.A. Al-Hemaid, A sensitive and selective enzyme-free amperometric glucose biosensor using a composite from multi-walled carbon nanotubes and cobalt phthalocyanine, RSC Adv. 5 (2015) 26762–26768. doi:10.1039/C4RA17161F. [30] C. Medina-Plaza, G. Revilla, R. Muñoz, J.A. Fernández-Escudero, E. Barajas, G. Medrano, J.A. de Saja, M.L. Rodriguez-Mendez, Electronic tongue formed by sensors and biosensors containing phthalocyanines as electron mediators: 21 Application to the analysis of red grapes, J. Porphyr. Phthalocyanines. 18 (2014) 76–86. doi:10.1142/S1088424613501137. [31] C. Garcia-Hernandez, C. Salvo Comino, F. Martín-Pedrosa, M.L. Rodriguez- Mendez, C. Garcia-Cabezon, Impedimetric electronic tongue based on nanocomposites for the analysis of red wines. Improving the variable selection method, Sensors Actuators, B Chem. 277 (2018) 365–372. doi:10.1016/j.snb.2018.09.023. [32] L. Cui, T. Pu, Y. Liu, X. He, Layer-by-layer construction of graphene/cobalt phthalocyanine composite film on activated GCE for application as a nitrite sensor, Electrochim. Acta. 88 (2013) 559–564. doi:10.1016/j.electacta.2012.10.127. [33] V. V. Singh, A.K. Nigam, A. Batra, M. Boopathi, B. Singh, R. Vijayaraghavan, Applications of Ionic Liquids in Electrochemical Sensors and Biosensors, Int. J. Electrochem. 2012 (2012) 1–19. doi:10.1155/2012/165683. [34] S. Liu, Hao; Wu, Xing; Sun, Jianliang; Chen, Stimulation of Laccase Biocatalysis in Ionic Liquids: A Review on Recent Progress, Curr. Protein Pept. Sci. 19 (2018) 100–111. [35] J. Hong, Y.X. Zhao, B.L. Xiao, A.A. Moosavi-Movahedi, H. Ghourchian, N. Sheibani, Direct electrochemistry of hemoglobin immobilized on a functionalized multi-walled carbon nanotubes and gold nanoparticles nanocomplex-modified glassy carbon electrode, Sensors (Switzerland). 13 (2013) 8595–8611. doi:10.3390/s130708595. [36] J.Y. Sun, K.J. Huang, S.F. Zhao, Y. Fan, Z.W. Wu, Direct electrochemistry and electrocatalysis of hemoglobin on chitosan-room temperature ionic liquid-TiO2- 22 graphene nanocomposite film modified electrode, Bioelectrochemistry. 82 (2011) 125–130. doi:10.1016/j.bioelechem.2011.06.007. [37] J.Q. Zeng, S.N. Sun, J.P. Zhong, X.F. Li, R.X. Wang, L.N. Wu, L. Wang, Y.J. Fan, Pd nanoparticles supported on copper phthalocyanine functionalized carbon nanotubes for enhanced formic acid electrooxidation, Int. J. Hydrogen Energy. 39 (2014) 15928–15936. doi:10.1016/j.ijhydene.2014.04.048. [38] R.A. Hatton, N.P. Blanchard, V. Stolojan, A.J. Miller, S.R.P. Silva, Nanostructured copper phthalocyanine-sensitized multiwall carbon nanotube films, Langmuir. 23 (2007) 6424–6430. doi:10.1021/la070156d. [39] Y. Wang, H.Z. Chen, H.Y. Li, M. Wang, Fabrication of carbon nanotubes/copper phthalocyanine composites with improved compatibility, Mater. Sci. Eng. B Solid-State Mater. Adv. Technol. 117 (2005) 296–301. doi:10.1016/j.mseb.2004.12.007. [40] R. Seoudi, G.S. El-Bahy, Z.A. El Sayed, FTIR, TGA and DC electrical conductivity studies of phthalocyanine and its complexes, J. Mol. Struct. 753 (2005) 119–126. doi:10.1016/j.molstruc.2005.06.003. [41] Y. Jeon, J. Sung, D. Kim, C. Seo, H. Cheong, Y. Ouchi, R. Ozawa, H.O. Hamaguchi, Structural change of 1-butyl-3-methylimidazolium tetrafluoroborate + water mixtures studied by infrared vibrational spectroscopy, J. Phys. Chem. B. 112 (2008) 923–928. doi:10.1021/jp0746650. [42] J. Souto, Y. Gorbunova, M.L. Rodriguez-Méndez, S. Kudrevich, J.E. Van Lier, J.A. De Saja, Langmuir-Blodgett film formation and spectroscopic characterization of sulphonated derivatives of zinc phthalocyanine, J. Raman Spectrosc. 27 (1996) 649–655. doi:10.1002/(SICI)1097- 23 4555(199609)27:9<649::AID-JRS9>3.0.CO;2-B. [43] S.A. Dharaskar, K.L. Wasewar, M.N. Varma, D.Z. Shende, C.K. Yoo, Synthesis, characterization and application of 1-butyl-3-methylimidazolium tetrafluoroborate for extractive desulfurization of liquid fuel, Arab. J. Chem. 9 (2016) 578–587. doi:10.1016/j.arabjc.2013.09.034. [44] V. Srinivasa Rao, T. Vijaya Krishna, T. Madhu Mohan, P. Madhusudana Rao, Thermodynamic and volumetric behavior of green solvent 1-butyl-3- methylimidazolium tetrafluoroborate with aniline from T = (293.15 to 323.15) K at atmospheric pressure, J. Chem. Thermodyn. 100 (2016) 165–176. doi:10.1016/j.jct.2016.04.024. [45] M. Norman, J. Zdarta, P. Bartczak, A. Piasecki, I. Petrenko, H. Ehrlich, T. Jesionowski, Marine sponge skeleton photosensitized by copper phthalocyanine: A catalyst for Rhodamine B degradation, Open Chem. 14 (2016) 243–254. doi:10.1515/chem-2016-0025. [46] F. Lu, M. Bao, C. Ma, X. Zhang, D.P. Arnold, J. Jiang, Infrared spectra of phthalocyanine and naphthalocyanine in sandwich-type (na)phthalocyaninato and porphyrinato rare earth complexes. Part 3. The effects of substituents and molecular symmetry on the infrared characteristics of phthalocyanine in bis(phthal, Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 59 (2003) 3273– 3286. doi:10.1016/S1386-1425(03)00158-6. [47] L.S. Koodlur, Layer-by-layer self assembly of a water-soluble phthalocyanine on gold. Application to the electrochemical determination of hydrogen peroxide, Bioelectrochemistry. 91 (2013) 21–27. doi:10.1016/j.bioelechem.2012.12.001. [48] L. Gaffo, C.J.L. Constantino, W.C. Moreira, R.F. Aroca, O.N. Oliveira, 24 Vibrational spectra and surface-enhanced resonance Raman scattering of palladium phthalocyanine evaporated films, J. Raman Spectrosc. 33 (2002) 833– 837. doi:10.1002/jrs.924. [49] M. Romero-arcos, M.G. Garnica-romo, H.E. Martínez-flores, Electrochemical Study and Characterization of an Amperometric Biosensor Based on the Immobilization of Laccase in a Nanostructure of TiO 2 Synthesized by the Sol- Gel Method, (2016) 8–13. doi:10.3390/ma9070543. [50] P.J. Yoo, K.T. Enam, J.F. Qi, S.K. Lee, J. Park , A.M. Belcher, P.T. Hammond, Spontaneous assembly of viruses on multilayered polymer surfaces, Nature Materials 5(2006) 234–240. doi: 10.1038/nmat1596. [51] A.V. Straeten, A. Bratek-Skicki, A. M. Jonas, C.A. Fustin, C. Dupont- Gillain, Integrating Proteins in Layer-by-Layer Assemblies Independently of their Electrical Charge. ACS Nano 12 (2018) 8372-838. doi: 10.1021/acsnano.8b03710. [52] C. García-Hernández, C. García-Cabezón, F. Martín-Pedrosa, J.A. De Saja, M.L. Rodríguez-Méndez, Layered composites of PEDOT/PSS/nanoparticles and PEDOT/PSS/phthalocyanines as electron mediators for sensors and biosensors, Beilstein J. Nanotechnol. 7 (2016) 1948–1959. doi:10.3762/bjnano.7.186. [53] J. Zhang, J. Xu, Y. Wen, Z. Wang, H. Zhang, W. Ding, Voltammetric determination of phytoinhibitor maleic hydrazide using PEDOT:PSS composite electrode, J. Electroanal. Chem. 751 (2015) 65–74. doi:10.1016/j.jelechem.2015.05.032. [54] C. Apetrei, J. Saja, J. Zurro, M. Rodríguez-Méndez, Advantages of the Biomimetic Nanostructured Films as an Immobilization Method vs. the Carbon 25 Paste Classical Method, Catalysts. 2 (2012) 517–531. doi:10.3390/catal2040517. [55] M.M. Rodríguez-Delgado, G.S. Alemán-Nava, J.M. Rodríguez-Delgado, G. Dieck-Assad, S.O. Martínez-Chapa, D. Barceló, R. Parra, Laccase-based biosensors for detection of phenolic compounds, Trends Anal. Chem. 74 (2015) 21–45. doi:10.1016/j.trac.2015.05.008. [56] S. Sadeghi, E. Fooladi, A New Amperometric Biosensor Based on Fe 3 O 4 / Polyaniline / Laccase / Chitosan Biocomposite-Modified Carbon Paste Electrode for Determination of Catechol in Tea Leaves, (2015) 1603–1616. doi:10.1007/s12010-014-1380-6. [57] X. Zhou, L. Liu, X. Bai, H. Shi, A reduced graphene oxide based biosensor for high-sensitive detection of phenols in water samples, Sensors Actuators B. Chem. 181 (2013) 661–667. doi:10.1016/j.snb.2013.02.021. [58] Y. Li, L. Zhang, M. Li, Z. Pan, D. Li, A disposable biosensor based on immobilization of Laccase with silica spheres on the MWCNTsdoped screenprinted electrode, Chem. Cent. J. (2012) 2–9. 10.1186/1752-153X-6-103. [59] R.S. Freire, N. Dura, L.T. Kubota, Effects of fungal Laccase immobilization procedures for the development of a biosensor for phenol compounds, 54 (2001) 681–686. [60] M.L. Antonelli, C. Tortolini, F. Mazzei, S. Cannistraro, C. Lanzellotto, G. Favero, E. Coppari, Nanostructured enzymatic biosensor based on fullerene and gold nanoparticles: Preparation, characterization and analytical applications, Biosens. Bioelectron. 55 (2013) 430–437. doi:10.1016/j.bios.2013.12.028. [61] C. Medina-Plaza, J.A. de Saja, M.L. Rodriguez-Mendez, Bioelectronic tongue 32 Figure 5. CV registered at increasing scan rates from 10 to 1000 mV/s immersed in 10-4 M catechol in 0.01 M phosphate buffer (pH 7.00) for: a) the [CHI(+)+IL(+)|CuPcS(-)]2 sensor; and b) the [CHI(+)+IL(+)|CuPcS(-)]2|Lac biosensor. The insets show the linear relationship between Ipc and the square root of the scan rate. 33 Figure 6. Relationship of the amperometric responses to catechol addition with the working electrode potential fixed at −200 mV immersed in 0.01 M phosphate buffer (pH 7.00) for the [CHI(+)+IL(+)| CuPcS(-)]2 sensor (upper) and the [CHI(+)+IL(+)|CuPcS(-)]2|Lac biosensor (lower). Error bars correspond to the errors registered in three replicate experiments. 34 Table 1. FTIR bands of the [CHI(+)+IL(+)|CuPcS(-)]2 sensor and of the individual components Wavelength (cm-1) IL(+) (cm-1) CHI(+) (cm-1) CuPcs(-) (cm-1) Assignment 3424 3478s OH stretching vibrations, Intermolecular H Bonds 2926 2973 2924 2923 (C-H) asymmetric stretching vibration in alkyl 2845 2888 2856 2854 (C-H) asymmetric stretching vibration in alkyl 1657 1656 C=O stretching in amide group 1647 1652 the C=C and C=N stretching 1610 1612 (C-C) stretching vibration in pyrrole 1546 1572 C-C stretching of the imidazole ring 1546 1571 N-H bending 1510 1542 (C-H) bending vibration 1461 1463s CH3 and CH2 asymmetric bending of alkyl substituent in imidazolium ionic liquids 1456 1469 1468sh Isoindole stretching 1456 1458sh 1450 (C-H) in plane bending 1419 1422 (CH-OH) bending 1395 1378 (CH2OH) 1338 1330vs (C-C) in isoindole 1216 1410 S=O Symmetric stretching vibration 1169s 1167 C-N stretching 1150 1145 S=O Symmetric stretching vibration 1093 1114vs β(C-H) bending in plane 1072 1069 C-H deformation in plane 1051 1048 S-O stretching 1027vs 1060 ν(C-N) stretching in pyrrole vibration 832 847 C-H bending 742 744 C-H plane bending 720 723vs γ(C-H) out of plane deformation vs: very strong, s: strong, sh: shoulder, w:weak 35 Table 2. Comparison of analytical parameters of different biosensors dedicated to the detection of catechol. Biosensor description Potential (V) R2 𝑲 𝒂𝒑𝒑 𝑴 (µM) Sensitivity (A M−1) LOD (M) [Catechol] (µM) Ref. [CHI(+)+IL(+)|CuPcS(-)]2|Lac -0.2 0.981 3.16 0.23 9.98·10-9 2.4-14.9 This work Lac/PANI/GCE --- 0.989 --- 0.706 2.07·10-6 3.2-19.6 [8] Fe3O4-PANI/Lac/CHI/CPE -1.5 0.995 1.09 126.00 4.0·10-7 0.5-80 [56] Lac/AP-rGOs/GCE 0.37 0.998 3000 15.79 7.0·10-6 15-700 [57] Lac/Si/MWCNTs/SPEs -0.12 0.991 3.78 2780.00 4.2·10-7 1.3-85.5 [58] Carbon-fiber/Lac -0.1 0.999 610 0.33 --- 1-10 [59] Au-SAM/AuNPs- Linker/Fullerenols/Lac -0.1 0.999 0.66 --- 6.0·10-6 30-300 [60] Lac/AA/LuPc2 0.06 0.992 --- 0.360 5.18·10-7 4-150 [61] TiO2/NAF/Lac --- 0.996 --- 2.94 1.25·10-6 0.75-150 [62] MMCNTs/Lac/CHI -0.05 0.999 --- 0.279 3.34·10-8 0.1-165 [63] 36 Table 3. Comparison of the results obtained with the sensor and the corresponding biosensor Sensor description Intensity Current (µA) R2 𝑲 𝒂𝒑𝒑 𝑴 (µM) Sensitivity (A M−1) LOD ·108 (M) [CHI(+)+IL(+)|CuPcS(-)]2 -12 0.993 --- 0.070±0.001 2.17±0.17 [CHI(+)+IL(+)|CuPcS(-)]2|Lac -33 0.997 3.16 0.237±0.001 0.08±0.001 3 Figure S.2. FTIR spectra of LbL [CHI(+)|CuPcS(-)|IL(+)|CuPcS(-)]n films with increasing number of layers (n = 4,8,12,16,20,24,28,32). The inset shows the correlation between the transmittance measured at 1027 cm-1 and the number of layers. 4 Figure S.3. Cyclic voltammograms of a [CHI(+)+IL(+)|CuPcS(-)]n with increasing number of layers (n = 0,24,8,12,16,20) immersed in 10-4 M catechol in 0.01 M phosphate buffer (pH 7.00). Scan rate 100 mV.s-1. The inset shows the correlation between the intensity current at -100mV and the number of layers. 5 Figure S4. Cyclic voltammograms of a bare ITO and ITO|Lac immersed in 10-4 M catechol in 0.01 M phosphate buffer (pH 7.00). Scan rate 100 mV.s-1. 6 Figure S.5. Cyclic voltammograms of a) [CHI(+)+IL(+)|CuPcS(-)]2, b) [CHI(+)|CuPcS(-)|IL(+)|CuPcS(-)]2 and c) [CHI(+)+IL(+)|CuPcS(-)]2|Lac immersed in 10-4 M catechol in 0.01 M phosphate buffer (pH 7.00). Scan rate 100 mV.s-1. Cycles 1,3,5,7 and 10 are shown. 7 Figure S.6. Cyclic voltammograms of 3 different sensors prepared under the same condition of a) [CHI(+)+IL(+)|CuPcS(-)]2, and b) [CHI(+)+IL(+)|CuPcS(-)]2|Lac immersed in 10-4 M catechol in 0.01 M phosphate buffer (pH 7.00). Scan rate 100 mV.s-1. 8 Figure S.7. Linear relationship between Epc vs. log V shown by the a) [CHI(+)+IL(+)|CuPcS(-)]2 sensor and b) [CHI(+)+IL(+)|CuPcS(-)]2 |Lac biosensor immersed in 10-4 M catechol in 0.01 M phosphate buffer (pH 7.00). 9 Figure S.8. Linear relationship between log Ipc vs.  shown by the a) [CHI(+)+IL(+)|CuPcS(-)]2 sensor and b) [CHI(+)+IL(+)|CuPcS(-)]2 |Lac biosensor immersed in 10-4 M catechol in 0.01 M phosphate buffer (pH 7.00).