Renewable and Sustainable Energy Reviews Volume 91, August 2018, Pages 741–753 *Corresponding author. Tel.: +34 935099250 Email address:
[email protected] Decision-making tool for the optimal selection of a domestic water-heating system considering economic, environmental and social criteria: application to Barcelona (Spain) Maria del Mar Casanovas-Rubioa,*, Jaume Armengoua a Universitat Internacional de Catalunya, 22 Immaculada, 08017 Barcelona, Spain Abstract The research presented in this paper has two main objectives. First, it aims to generate an assessment tool for ranking and selecting the most sustainable domestic waterheating system (WHS) (with the lowest economic, environmental and social impact) that could be applied in any location and with any demand. Second, it aims to ascertain which WHS is the most sustainable in places with a climate and solar radiation like that of Barcelona, Spain, where a minimum solar contribution to domestic water heating is compulsory for new buildings and significant renovations. Multi-criteria decision analysis was employed to create the optimised flexible assessment tool. The Delphi method was followed to perform the surveys, and to provide the objectivity required in the identification of impacts, the definition of indicators and the assignment of weights. The most relevant criteria were determined: annual cost, material consumption, energy consumption, GHG emissions, space requirement, visual impact and occupational risks. The resulting tool was tested by analysing twelve domestic WHS, including two conventional systems, and ten combinations of five solar thermal technologies with two conventional systems as backup for a changing room in a sport centre located in Barcelona. The two conventional WHS studied were a natural gas-fired condensing boiler and an electric water heater. The five solar thermal technologies were: a flat plate with a harp design, a flat plate with a serpentine design, a heat-pipe evacuated tube, a direct-flow evacuated tube, and a direct-flow evacuated tube with CPC. The dynamic thermal simulation programme T*SOL was used to dimension the solar thermal systems. Two sensitivity analyses were carried out: one on weights and one on references. The tool proved very useful in the assessment of these systems, and could also help in decision-making processes to select the most sustainable WHS for other locations and domestic hot water demands. Keywords: sustainability, domestic water-heating systems, solar collectors, multicriteria decision analysis, indicators, environmental impact.
2 Contents 1. Introduction...……………………………………………………………………………......2 2. Literature review......................................................................................................... 4 3. Methods...………………………………………………………………………………........6 3.1. Identification of impacts……………………….......................................................8 3.2. Definition of indicators……………………….........................................................8 3.3. Weight assignment………………………............................................................10 3.4. Definition of the Impact Index………………………............................................14 4. Case study………………………………………………………………………...............15 4.1. Introduction……………………………………………….......................................15 4.2. Results………………………………………………..............................................19 4.3. Sensitivity analyses………………………………………………...........................23 4.3.1. Sensitivity analysis of the weights...................................................….....23 4.3.2. Sensitivity analysis of the reference.........................................................26 5. Conclusions………………………………………………..............................................28 Acknowledgements………………………………………………......................................30 References………………………………………………...................................................30 1. Introduction The final energy consumption of the residential sector in the European Union (EU) accounted for 26.8% of the total energy consumption in 2013. This was the highest percentage of all sectors; even slightly above that of road transport or industry [1]. Water heating was responsible for about a quarter of this energy consumption [2]. Furthermore, households accounted for 19% of greenhouse gas (GHG) emissions in the EU in 2012 [1]. Residential energy consumption in Spain accounted for 18.5% of the total energy consumption in the same country, and 5.4% of the total residential energy consumption in the EU (28 countries) in 2015 [3]. Household GHG emissions in Spain accounted for 20.4% of the total GHG emissions in the same country, and 7.5% of the total household GHG emissions in the EU in 2014 [4]. Thus, the appropriate choice of a domestic waterheating system (WHS) can largely reduce energy consumption and operational costs, and protect the environment [5]. Domestic solar water heating is a well-developed technology that is used to reduce energy consumption for domestic hot water (DHW) supply [2]. Its potential for significantly reducing domestic energy consumption is recognised [2]. Legislation on
3 buildings is progressively introducing domestic solar WHS. Consequently, the total installed capacity is increasing every year, and reached 33.3 GWth in operation in 2015 in the EU 28 and Switzerland, which generated an estimated 23.5 TWhth of solar thermal energy while contributing to a saving of 6.3 MtCO2 [6]. In the case of Spain, the total installed capacity in operation in 2015 was 2296 MWth [6]. All three pillars of sustainability, economic, social and environmental factors, must be considered in decisions on the most appropriate WHS for a given location and demand, to obtain a comprehensive view of the system. In fact, sustainability consists of finding a balance between these three dimensions, and is therefore an interdisciplinary problem. If an analysis is limited to one or two dimensions, the view of the problem will only be partial. However, in the literature review presented in the next section, few studies were found that compare types of solar collector systems including flat plates, evacuated tubes and conventional systems for producing DHW from a complete, sustainable, multicriteria perspective that includes social, economic and environmental aspects. Further comparative studies of solar and conventional commercial WHS are needed to help policy makers, installers and users to make decisions on the most sustainable WHS [7]. The research presented in this paper has two main objectives: (1) to develop a multicriteria decision-making tool applicable to any location and demand that enables prioritisation and selection of the best WHS, including solar and conventional systems and considering the three dimensions of sustainability, and (2) to illustrate the use of the tool with a case study and determine the best WHS to be used in a sport centre located in Barcelona, Spain. This research extends knowledge by providing a multi-criteria tool for sustainable decision making on WHS. It is innovative as it applies multi-attribute utility theory (MAUT) to a new area: selection of the best domestic WHS. It explores the interdisciplinary connection between fields of knowledge in solar and conventional WHS. It connects engineering with economy, environment and society, in other words, it looks at engineering from the perspective of sustainability; and sustainability is fundamental for present and future generations. According to the present study and under the studied climatic and hot water demand conditions, policies that encourage the installation of flat plate solar WHS are justified, particularly in a society that increasingly recognises the value of the environment and calls for a reduction in GHG emissions and conventional energy consumption.
4 The rest of the paper is organised as follows. The second section presents a literature review of research on technical, economic and environmental aspects of solar WHS and multi-criteria decision analysis (MCDA) applied to the energy sector, particularly to renewable energies and domestic solar WHS. The third section develops a decisionmaking tool for selecting optimal domestic WHS based on MAUT and the Delphi method. In the fourth section, a case study on determining the optimal WHS out of twelve alternatives is solved by using the proposed tool and simulations with T*SOL software. The fifth and last section of the paper presents the conclusions of the study. 2. Literature review The definition of energy policies and the selection of the best WHS should be based on evaluating the sustainability of existing technologies, considering all three pillars of sustainability, economic, environmental and social factors, in an integrated way. However, much of the current literature on solar WHS has focused on technical, economic or environmental aspects separately. Some previous studies on solar WHS have focused on technical and economic aspects. For example, Tian and Zhao [8] and Jamar et al. [9] reviewed solar collectors for low- and high-temperature applications in terms of optical optimisation, heat loss reduction, heat recuperation enhancement and sun-tracking mechanisms. Allouhi et al. [10] studied the technical performance of flat plate and evacuated tube collectors in several locations in Morocco. Buker and Riffat [11] reviewed the current status of building-integrated solar thermal collectors. Wang et al. [12] reviewed solar WHS in terms of technical background, market potential and research questions. Gautam et al. [13] reported studies on technical advancements, economic feasibility and the overall scenario of solar WHS. Islam et al. [14] and Shukla et al. [15] discussed the design features, energy efficiency and cost effectiveness of solar WHS. Al-Badi and Albadi [16] and Benli [17] evaluated technical and economic aspects of solar WHS in Oman and Turkey, respectively. Vieira et al. [18] concluded that split systems performed better than thermosiphon in Brisbane, Australia, in terms of energy efficiency and level of service, and hence should be prioritised in energy efficiency policies. Additionally, several recent studies have reported on environmental and economic aspects of solar WHS. For example, Ibrahim et al. [5] qualitatively reviewed the operational costs, environmental effects and performance of existing WHS. Lamnatou et al. [19] critically reviewed the existing life-cycle analyses on building-integrated solar
5 thermal systems. Greening and Azapagic [20] quantified the environmental impact of solar WHS in regions with low solar radiation, such as the UK, while Koroneos and Nanaki [21] quantified the environmental impact and economic performance in Thessaloniki, Greece. Shaddel and Shokouhian [22] studied the payback period and the annual reduction in natural gas consumption and CO2 emissions due to the installation of solar thermal collectors in a multiple-dwelling complex in Mashhad, Iran. Bessa and Prado [23] assessed the reduction of CO2 emissions with the use of solar WHS in comparison with electric showers in social housing in several Brazilian climatic zones. Cassard et al. [24] and Friedrich Ferrer [25] analysed economic aspects of solar WHS, the former in the US and the latter in South Africa (SA). Their conclusions were similar: solar WHS are only economically attractive in a few regions. The high initial cost is a primary driver of the low penetration of residential solar WHS in the US: “the life-cycle benefits often do not greatly exceed the capital cost of the system” [24]. However, solar WHS provide other “benefits such as reduced reliance on fossil fuels and reduced carbon dioxide emissions” but these are somehow “external to the consumer and difficult to quantify” [24]. In fact, the search for a logical, optimal solution to the sustainability of energy systems is a complex process that requires robust quantitative methods [26]. In this regard, MCDA could become a powerful tool for decision making on sustainable energy systems [26, 27]. There are several studies on renewable energies and domestic solar WHS based on MCDA. Troldborg et al. [28] assessed the sustainability of eleven renewable energy technologies considering three environmental, three technical, and three socioeconomic criteria using the PROMETHEE method. They considered uncertainty in the input information using a Monte Carlo simulation. As the assessment was performed at national level and hence was not specific, the uncertainty associated with the criteria and the ranking was high. They stated that the degree of uncertainty for actual site-specific projects would probably be lower. Stein [29] developed a model to rank nine renewable and non-renewable electricity production technologies considering financial, technical, environmental and socio-economic-political criteria using the analytic hierarchy process (AHP). A sensitivity analysis of the weights was performed considering four scenarios. It was concluded that solar, wind, hydropower and geothermal provide the most overall benefits and, therefore, policies to encourage the use of these type of energies should be expanded. Cavallaro [30] used the multi-criteria PROMETHEE method to rank twelve solar thermal technologies according to seven economic and technical criteria, and determined the weight stability intervals within which the weight of each criterion can be modified without changing the ranking. Nixon et al. [31] designed a new solar thermal
6 collector using an MCDA including quality function development, the AHP and the Pugh selection matrix and sixteen technical, financial and environmental criteria. Notwithstanding the increasing use of solar WHS, the improved technology, and the recognised environmental advantages in terms of energy consumption and GHG emissions, the overall sustainability (that covers all three pillars) of these methods in comparison with each other and in relation to conventional systems is not yet clear. Neither is it clear which is the best system from the perspective of sustainability for use in a specific location with specific demands. Comparative studies of all the main commercially available solar WHS configurations and types of solar collectors are needed [7]. In this area, Hang et al. [7] carried out a relevant study in which six types of domestic WHS including two types of solar collectors (flat plate and evacuated tube) in combination with two types of auxiliary systems (natural gas and electricity) and two conventional systems (natural gas and electricity) were evaluated from energy, economic and environmental perspectives. 3. Methods MCDA can help to select the best of several alternatives taking into account possible conflicts between criteria, considering that the best alternative according to one criterion is not necessarily the best according to another criterion. Therefore, the best alternative overall cannot be determined directly. In this sense, the MCDA is an integrated approach that enables overall assessment, comparison, and ranking of alternatives, considering all the criteria in an integrated manner. While it is necessary to be aware of uncertainties and analyse how they may affect the result [28, 31], MCDA can be a useful technicalscientific tool for decision-making support [30, 31]. As described in Martin-Gamboa et al. [26], an increasing number of studies on energy policy and management use MCDA for energy planning and to evaluate aspects of renewable energies [29,32]. Within MCDA, the multi-attribute utility theory (MAUT) [33] is the most commonly used for assessing the sustainability of energy systems, according to Martin-Gamboa et al. [26]. MAUT was chosen for the study presented in this paper as it helps to solve discrete problems, it can be understood intuitively, and it is based on a solid foundation [34]. To improve and verify the quality and robustness of the tool generated using MAUT, several strategies and methods were followed: the Delphi method, controls in the surveys to minimise and avoid bias, and two sensitivity analyses in the case study to check the
7 robustness of the results. These strategies are explained in the present section and in Section 4.3. Sensitivity analyses. Fig. 1 shows the steps taken to develop an Impact Index for evaluating domestic WHS, according to MAUT in combination with the Delphi method, and the application of the Impact Index to a case study. Fig. 1. The main steps used to develop the decision-making tool based on MAUT for the optimal selection of domestic WHS, and a practical application. The Delphi method for construction and engineering management is a structured research method that can be used to obtain highly reliable data from certified experts by means of strategically designed surveys [35]. This method was used to select the experts, administer rounds of surveys, and define consensus to obtain the data required to apply the MAUT, including the identification of impacts, the definition of indicators and the weight assignment. Sixteen panellists were initially contacted to complete the surveys, following the Delphi method [35]. Thirteen responded and participated, which is more than the minimum number (8-12) recommended by Hallowell and Gambatese [35]. All the panellists met the expertise requirements of the Delphi method [35], either those of the rigorous or the flexible implementation of the method, since academic experience was not particularly relevant to the study. This results in the incorporation of highly qualified and well-rounded panellists. They were representative of stakeholders related to solar thermal systems for DHW: design, project, and management engineers and architects, including some academics. 3.1. Identification of impacts Impacts were identified based on previous and preliminary research [26, 28-30, 34, 36, 37] and adapted to the research goal according to the experts’ comments in the surveys. 1. Identification of impacts 2. Definition of indicators 3. Weight assignment 4. Definition of the Impact Index Delphi method Controls 5. Case study Sensitivity analyses
8 The study evaluated the impacts presented in Fig. 2 classified into three criteria (economic impact, environmental impact and social impact) and seven subcriteria (annual cost, material consumption, energy consumption, GHG emissions, space requirement, visual impact, and occupational risks). 3.2. Definition of indicators According to the experts’ comments, a quantitative indicator was defined for each subcriterion as presented in Fig. 2. Indicators 𝐼𝐼1 and 𝐼𝐼2 include the possibility of integrated solar collectors instead of some construction material. The space requirement (𝐼𝐼5) includes common and private space occupied by the WHS. In the case of solar collectors installed on sloping roofs or facades, there is the risks of falls to lower levels when working at heights during installation and maintenance (𝐼𝐼7).
9 1In case of integrated collectors that replace construction materials Fig. 2. Impacts of domestic WHS and their indicators. Definition of indicators Units Indicator number Subcriteria Criteria € 𝑦𝑦𝑦𝑦𝑦𝑦𝑦𝑦 Annual installation, use and maintenance cost minus cost savings due to material savings 1 Annual cost I1 Economic impact 𝑘𝑘𝑘𝑘 Mass of the materials required for the installation minus material savings 1 Material consumption I2 Energy consumption Annual water-heating energy consumption 𝑘𝑘𝑘𝑘ℎ 𝑦𝑦𝑦𝑦𝑦𝑦𝑦𝑦 Environmental impact I3 GLOBAL IMPACT 𝑘𝑘𝑘𝑘𝑘𝑘𝑘𝑘2𝑦𝑦 𝑦𝑦𝑦𝑦𝑦𝑦𝑦𝑦 Annual mass of CO 2 e emissions due to water heating GHG emissions I4 𝑚𝑚2 Floor surface that cannot be used for other purposes because it is occupied by the water-heating installation Space requirement I5 𝑚𝑚2 I6 Visual impact Social impact Occupational risks Surface of non-integrated solar collectors that can be seen from the street ℎ 𝑦𝑦𝑦𝑦𝑦𝑦𝑦𝑦 Time of work at heights on facades or sloping roofs I7
16 Table 6. DHW demand at a reference temperature of 60º and annual minimum solar contribution for a changing room designed for 100 people in climatic zone III according to the three applicable legislative acts. Legislation DHW demand at a reference temperature of 60º Annual minimum solar contribution (l/day·person) (l/day) (%) (l/day) Spanish 21 2100 40 840 Catalan 20 2000 50 1000 Local from Barcelona 15 1500 60 900 The use of the Joule effect (electric water heater) as a support system for the solar thermal domestic WHS system is penalised in the regional and local legislation by demanding a higher annual minimum solar contribution (70% and 63% respectively). However, alternatives must be similar if they are to be compared. Therefore, for this study, all the alternatives with a solar thermal contribution were calculated with a solar contribution of 50% (1000 l/day), whether supported by natural gas or the Joule effect. The domestic solar WHS studied were: two types of flat plate and three types of evacuated tube in combination with two types of conventional energy as a backup system, plus two types of conventional energy alone. Hence, there were a total of twelve alternatives, as presented in Fig. 3. Current legislation does not allow conventional energy alone for domestic water heating in new buildings, but such systems are still widely used in old buildings and including them in the comparison is interesting. Fig. 4 and 5 present the configuration of the domestic solar WHS with a natural gas-fired condensing boiler and an electric water heater respectively as the backup system considered in this study.
17 Fig. 3. Solar thermal collectors in combination with conventional energy as a backup and conventional energy alone for domestic water heating, as analysed in this study. Fig. 4. Schematic diagram of the solar WHS with a natural-gas condensing boiler as a backup considered in this study. Solar radiation Solar collector Solar heat exchanger Solar storage tank Conventional storage tank Condensing boiler Hot water supply Cold water supply Heat exchanger SOLAR ENERGY CONVENTIONAL ENERGY Flat plate – harp design Flat plate – serpentine design Evacuated tube – heat pipe Evacuated tube – direct flow Evacuated tube – direct flow with CPC Natural gas-fired condensing boiler Electric water heater - Solar thermal collectors Conventional energy
18 Fig. 5. Schematic diagram of the solar WHS with an electric water heater as a backup considered in this study. The backup system must be dimensioned to cover the peak demand of DHW even if there is a solar thermal system. Therefore, the power of the natural gas-fired condensing boiler should be the same whether it works alone or as the backup for the solar thermal system. The same applies to the electric water heater. T*SOL (www.valentin-software.com), a dynamic thermal simulation programme, was used to dimension the five solar thermal systems in Fig. 3, considering the annual cycle of solar radiation and the hourly DHW demand of the changing room. The input data for the programme of the five solar thermal systems was obtained from current commercial systems. The most relevant of these data are presented in Table 7. The solar hot water storage tank was designed with a capacity of 2000 litres, and the DHW storage tank, 1000 litres. The power needed for the condensing boiler or electric water heater is 35 kW. Table 7. Data on the solar collectors used as input for the T*SOL simulation programme. Input data Flat plate Evacuated tube Harp Serpentine Heat pipe Direct flow Direct flow with CPC Tilt angle 1 45º 45º 25º 25º 25º Gross area (m2) 2.51 2.51 4.62 4.15 2.9 Aperture area (m 2 ) 2.4 2.37 3.19 3.22 2.57 Optical efficiency (%) 76.5 81.2 76.1 76.8 64.4 Solar radiation Solar collector Solar heat exchanger Solar storage tank Electric heater Hot water supply Cold water supply SOLAR ENERGY CONVENTIONAL ENERGY
19 Thermal loss correction value k1 (W/m 2 ·K) 3.653 3.478 1.047 1.36 0.749 Thermal loss correction value k2 (W/m 2 ·K 2 ) 0.012 0.018 0.007 0.0053 0.005 Dimensions (mm) 2187x1147x87 2187x1147x87 2241x2061x150 2125x1954x134 2057x1390x101 Price (€) 657 727 2919 2627 1625 1The tilt angles of the evacuated tubes are the closest to Barcelona latitude that can be achieved with the internal tilt angle of the tube. 4.2. Results The main results of the simulation with T*SOL are presented in Table 8. As can be seen, the systems have a similar solar contribution, as this was a requirement of the legislation, but they have different surface occupation and cost. The total energy consumption including solar and conventional energy amounts to 41267 kWh/year. Table 8. Output data of the T*SOL simulation programme. Output data Flat plate Evacuated tube Harp Serpentine Heat pipe Direct flow Direct flow with CPC Nº of collectors needed 11 10 7 7 9 Total aperture area (m2) 26.4 23.7 22.3 22.5 23.1 Floor surface occupied by the solar collectors (m 2 ) 20 (in a row) 17 (in a row) 50 45 40 Solar contribution (%) 51.51 50.61 52.52 52.22 52.93 System efficiency (%) 47.4 51.6 56.1 55.4 47.1 Consumption of conventional energy (kWh) 20027 20397 19565 19741 19401 Cost of the solar collectors (€) 7227 7270 20433 18389 14625 Table 9 presents data used to calculate the indicator of annual cost (I1). The installation cost includes the solar collectors and the rest of the elements of the solar WHS in addition to the conventional system. All the installation and maintenance costs were either obtained from current catalogues of real products or reported by professionals from the sector. To calculate the annual cost, a lifetime of 20 years was considered for the solar collectors, and 10 years for the rest of the elements. The use costs for the natural gas systems were calculated with the following gas tariff obtained from a gas company operating in Spain in 2016: a fixed part of the price of 54.22 €/month, and a part of the price depending on the gas consumption of 0.037731 €/kWh plus a special tax on
20 hydrocarbons of 0.00234 €/kWh. The use costs for electricity consumption were calculated according to the time-of-use tariffs obtained from an electricity company operating in Spain for a contracted power of more than 15 kW as indicated in Table 10, plus a special tax on electricity of 0.051127 €/€ of the contracted power and energy consumption costs. As more precise data for calculating the electricity costs were lacking, the electricity consumption profile was assumed to be the same as the demand profile for a changing room used in the T*SOL simulation programme. VAT was not included in any of the costs in Tables 9 and 10. Table 9. Installation, use, maintenance and total costs for the domestic WHS. Cost Conventional only Solar + natural gas-fired condensing boiler Solar + electric water heater Natural gasfired condensing boiler Electric water heater Flat plate Evacuated tube Flat plate Evacuated tube Harp Serpentine Heat pipe Direct flow Direct flow with CPC Harp Serpentine Heat pipe Direct flow Direct flow with CPC Installation (€) 15078 13569 26625 26668 39831 37787 34023 25116 25159 38322 36278 32514 Annual installation (€/year) 1507.80 1356.90 2301.15 2303.3 2961.45 2859.25 2671.05 2150.25 2152.4 2810.55 2708.35 2520.15 Annual use (€/year) 2304.24 7611.16 1453.16 1467.96 1434.64 1441.68 1428.06 4075.65 4116.28 4022.99 4042.34 4004.97 Annual maintenance (€/year) 60 10 1302.45 1189.5 1515.3 1367.25 1234.5 1252.45 1139.5 1465.3 1317.25 1184.5 Total annual (€/year) 3872.04 8978.06 5056.76 4960.76 5911.39 5668.18 5333.61 7478.35 7408.18 8298.84 8067.94 7709.62 Table 10. Time-of-use periods and tariffs for electricity considered in the case study. Tariff periods and tariff concepts Period Peak Mid peak Off peak Summer 11-15 h 8-11 h and 15-24 h 0-8 h Winter 18-22 h 8-18 h and 22-24 h 0-8 h Contracted power (€/kW/month) 3.394071 2.036455 1.357616 Energy consumption (€/kWh) 0.125362 0.106022 0.08082 As can be seen from Table 9, the installation costs are much higher for the solar WHS than for the conventional systems. This is because solar WHS require the same investment as conventional systems, plus the investment in the solar part of the system. The annual use costs, i.e. costs due to conventional energy consumption, are much lower for the solar WHS, due to the savings on conventional energy consumption. The annual maintenance is much higher for solar WHS than for conventional systems, due to the maintenance costs of solar WHS (considered to be 45 €/m2/year). Regarding the total annual costs, the natural gas WHS is the most economical, followed by the solar WHS with natural gas as the backup system, then the solar WHS with an electric heater as the backup. Finally, the electric heater is the most expensive due to the high electricity
21 costs. Therefore, using a natural gas-fired backup system is more economical than using an electric heater. This result is in agreement with Zainine et al. [43] in Tunisia. Even with reduced use costs due to energy savings, the solar WHS have higher total annual costs than the natural gas WHS, due to the higher initial investment in installation and maintenance costs. Within the solar WHS, flat-plate collectors have lower installation costs than evacuatedtube collectors. Regarding the annual use cost, all solar WHS with natural gas as a backup are very similar, because they have a very similar solar contribution (Table 8). The same applies to the various solar collectors with an electric heater as a backup. Regarding the total annual costs of the solar collectors with natural gas as a backup, the serpentine flat plate system is the most economical, closely followed by the harp flat plate, then the direct flow with CPC, direct flow and, finally, the heat pipe. As expected, the same ranking applies to the total annual costs of the various solar WHS with an electric heater. Table 11 presents the results of the indicators of Fig. 2 for the twelve WHS studied resulting from the combinations shown in Fig. 3. The annual cost (I1) includes the installation, use and maintenance costs. The material consumption indicator (I2) includes the materials from which the WHS is made. The annual energy (I3) and CO2 emissions (I4) include the use stage. The CO2 emissions have been calculated using the following factors: 0.357 and 0.252 kgCO2 per kWh of final energy for electricity and natural gas respectively, according to the Spanish Government [44]. The floor space used (I5) includes the space occupied by the WHS including the backup system, if any. None of the WHS can be seen from the street, resulting in no visual impact. Likewise, none of the studied alternatives are located on facades or sloping roofs. Therefore, none of them present risk of falls to lower levels during installation and maintenance operations. Therefore, the visual impact (I6) and occupational risks (I7) are not included in the subsequent stages of the analysis. The global weights of these subcriteria have been redistributed among the rest of the subcriteria (the subcriteria that are relevant to the comparison), so that the sum of their global weights is 100. They are presented in Table 12. Table 12 also presents the relative impacts and the Impact Index using Equation (2), which takes as a reference the worst result of the twelve alternatives for each indicator.
22 Table 11. Indicators of the impact caused by the twelve domestic WHS analysed in this study. Subcriteria Conventional Solar + natural gas-fired condensing boiler Solar + electric water heater Natural gas Electric water heater Flat plate Evacuated tube Flat plate Evacuated tube Indicator Harp Serpentine Heat pipe Direct flow Direct flow with CPC Harp Serpentine Heat pipe Direct flow Direct flow with CPC Annual cost (€/year) I1 3872.04 8978.06 5056.76 4960.76 5911.39 5668.18 5333.61 7478.35 7408.18 8298.84 8067.94 7709.62 Material consumption (kg) I 2 268 230 1249 1235 1318 1318 1161 1211 1197 1280 1280 1123 Energy consumption (kWh/year) I3 41267 41267 20027 20397 19565 19741 19401 20027 20397 19565 19741 19401 CO 2 emissions (kgCO2e/year) I 4 10399 14732 5047 5140 4930 4975 4889 7150 7282 6985 7048 6926 Floor space used (m 2 ) I 5 1.04 0.90 22.94 19.94 52.94 47.94 42.94 22.80 19.80 52.80 47.80 42.80 Visual impact (m 2 ) I 6 0 0 0 0 0 0 0 0 0 0 0 0 Occupational risks (h/year) I7 0 0 0 0 0 0 0 0 0 0 0 0 Table 12. Relative impacts and Impact Indexes for the twelve alternatives calculated using Equation (2), and their ranking. Subcriteria Global weights (%) Conventional Solar + natural gas-fired condensing boiler Solar + electric water heater Natural gas Electric water heater Flat plate Evacuated tube Flat plate Evacuated tube Harp Serpentine Heat pipe Direct flow Direct flow with CPC Harp Serpentine Heat pipe Direct flow Direct flow with CPC Annual cost 51.2 0.431 1.000 0.563 0.553 0.658 0.631 0.594 0.833 0.825 0.924 0.899 0.859 Material consumption 10.7 0.203 0.175 0.948 0.937 1.000 1.000 0.881 0.919 0.908 0.971 0.971 0.852 Energy consumption 16.7 1.000 1.000 0.485 0.494 0.474 0.478 0.470 0.485 0.494 0.474 0.478 0.470 CO 2 emissions 11.9 0.706 1.000 0.343 0.349 0.335 0.338 0.332 0.485 0.494 0.474 0.478 0.470 Floor space used 9.5 0.020 0.017 0.433 0.377 1.000 0.906 0.811 0.431 0.374 0.997 0.903 0.808 Impact Index - 0.495 0.818 0.553 0.543 0.658 0.636 0.593 0.704 0.697 0.808 0.787 0.742 Ranking - 1 12 3 2 6 5 4 8 7 11 10 9 According to Tables 11 and 12, conventional WHS consume the least material. Within the solar WHS, the direct flow with the CPC system consumes the least material, followed by the serpentine flat plate and harp flat plate and, finally, the direct flow and heat pipe for both the solar WHS with a natural gas-fired condensing boiler as a backup and the solar WHS with an electric water heater as a backup. Regarding energy
23 consumption, all solar WHS consume less than a half of the energy consumed by conventional WHS, as that is a requirement of the legislation. Regarding CO2 emissions, the solar WHS with natural gas as a backup produce less than half the emissions of the natural gas WHS, and the same applies to the solar WHS with electric water heater in comparison with the electric WHS. Within solar WHS with natural gas as a backup and solar WHS with an electric water heater as a backup, the emissions are very similar due to the initial requirement of a minimum of 50% solar contribution. Conventional WHS require much less floor space than solar ones. Considering all the impacts and their assigned relative importance, the best alternative is the natural gas WHS with an impact of 0.495. It is closely followed by the flat plate with serpentine design WHS and natural gas as a backup, with an impact of 0.543 (4.8% higher than the best system). Following this are the flat plate with harp design, the directflow evacuated tube with CPC, the direct-flow evacuated tube and the heat-pipe evacuated tube, all of them with natural gas as a backup. The previous ranking is repeated within the solar WHS with an electric water heater as a backup. The electric WHS has the highest global impact. The best choices for a solar WHS are serpentine and harp flat plates, which agrees with the results of Hang et al. [7]. 4.3. Sensitivity analyses 4.3.1. Sensitivity analysis of the weights The proximity in the ranking between the two best alternatives suggests that a variation in the weights could produce a variation in the ranking. A sensitivity analysis was carried out to determine the stability of the results when the weights were changed. As the solar WHS are environmentally better in terms of energy consumption and CO2 emissions, the analysis tried to answer the following question: How much importance should society assign to the environmental factors so that the solar WHS are better overall, despite being more expensive, using more space and materials? To answer this question, the structured analysis presented in Table 13 was performed. The sensitivity analysis (1) corresponds to a reduction of 10% in the weight of the annual cost and the redistribution of this 10% between the rest of the subcriteria, keeping the previous proportionality between them. This corresponds to set weight (1a). If, with set weight (1a), there is no change in the ranking between conventional WHS and solar WHS, as is the case, the analysis continues with set weight (1b) with an additional reduction of 10% in the weight of the annual cost. The sensitivity analysis (1') is the same as in (1), except for the weight
24 redistribution, which is only between the two subcriteria that are favourable to solar systems: energy consumption and CO2 emissions. Analogue explanations apply to the rest of the sensitivity analyses (2)-(7) and (2')-(6'). The sensitivity analysis (8) corresponds to an increment in the weights of energy consumption and CO2 emissions, and this increment is redistributed between the rest of the subcriteria. Table 14 presents the resulting weights of the sensitivity analysis for which there is a change in priorities, i.e. at least one solar WHS appears to be as good as or better than the conventional WHS. The exception is the sensitivity analysis (2b), in which the weight of the subcriterion space requirement is null and the impact of natural gas WHS is 0.015 lower than serpentine WHS with natural gas. When the difference between impacts is lower than 0.010 impact units, both impacts are considered to be equal. Tables 15 and 16 present, respectively, the Impact Index and the rank obtained for the twelve alternatives for the different weight sets. Table 13. Sensitivity analysis name (number between parentheses) according to the subcriteria with intentionally modified weights and their incremental modification (percentage between parentheses) and to the weight redistribution. Weight redistribution Subcriteria whose weights were intentionally modified in the sensitivity analysis and their incremental modification Annual cost (-10%) Floor space used (-5%) Material consumption (-5%) Annual cost (- 10%) and floor space used (-5%) Annual cost (- 10%) and material consumption (-5%) Floor space used (-5%) and material consumption (-5%) Annual cost (- 10%), floor space used (- 5%) and material consumption (-5%) Energy consumption (+5%) and CO2 emissions (+5%) between the rest of the subcriteria (1) (2) (3) (4) (5) (6) (7) (8) between the subcriteria favourable to solar systems (energy consumption and CO2 emissions) (1') (2') (3') (4') (5') (6') - Table 14. Weight sets which lead to a priority change (except for weight set (2b)). Subcriteria Weight sets for the sensitivity analysis (%) original (1c) (1'a) (2b) (2'a) (3a) (3'a) (4a) (4'a) (5a) (5'a) (6a) (6'a) (7a) (8a) Annual cost 51.2 21.2 41.2 56.6 51.2 54.1 51.2 41.2 41.2 41.2 41.2 57.6 51.2 41.2 44 Material consumption 10.7 17.3 10.7 11.8 10.7 5.7 5.7 14.8 10.7 5.7 5.7 5.7 5.7 5.7 9.2 Energy consumption 16.7 27.0 22.5 18.5 19.6 17.6 19.6 23.1 25.5 23.3 25.5 18.8 22.5 28.4 21.7 CO2 emissions 11.9 19.2 16.1 13.1 14.0 12.6 14.0 16.4 18.1 16.6 18.1 13.4 16.1 20.2 16.9 Floor space used 9.5 15.3 9.5 0.0 4.5 10.0 9.5 4.5 4.5 13.2 9.5 4.5 4.5 4.5 8.2
25 Table 15. Impact Index of the twelve alternatives obtained for the different weight sets. Domestic WHS Weight sets for the sensitivity analysis original (1c) (1'a) (2b) (2'a) (3a) (3'a) (4a) (4'a) (5a) (5'a) (6a) (6'a) (7a) (8a) Convent. Natural gas 0.495 0.535 0.540 0.546 0.538 0.512 0.529 0.555 0.583 0.542 0.574 0.543 0.572 0.617 0.546 Electric water heater 0.818 0.707 0.818 0.903 0.867 0.855 0.860 0.834 0.867 0.823 0.860 0.909 0.909 0.909 0.843 Solar + natural gas-fired condensing boiler Flat plate Harp 0.553 0.546 0.539 0.565 0.552 0.531 0.527 0.560 0.539 0.513 0.513 0.535 0.526 0.513 0.534 Serpentine 0.543 0.537 0.531 0.560 0.546 0.521 0.518 0.555 0.534 0.504 0.506 0.528 0.521 0.509 0.526 Evacuated tube Heat pipe 0.658 0.658 0.634 0.622 0.629 0.639 0.629 0.629 0.605 0.626 0.605 0.615 0.600 0.576 0.623 Direct flow 0.636 0.639 0.615 0.608 0.612 0.616 0.607 0.615 0.591 0.604 0.586 0.597 0.583 0.562 0.605 Direct flow with CPC 0.593 0.593 0.575 0.571 0.574 0.577 0.570 0.575 0.555 0.567 0.552 0.562 0.550 0.532 0.567 Solar + electric water heater Flat plate Harp 0.704 0.626 0.670 0.733 0.707 0.693 0.683 0.690 0.672 0.646 0.648 0.708 0.686 0.651 0.674 Serpentine 0.697 0.618 0.663 0.730 0.703 0.685 0.676 0.686 0.669 0.638 0.643 0.703 0.682 0.649 0.668 Evacuated tube Heat pipe 0.808 0.736 0.763 0.788 0.781 0.798 0.783 0.757 0.736 0.757 0.738 0.785 0.757 0.711 0.761 Direct flow 0.787 0.718 0.745 0.774 0.765 0.776 0.762 0.744 0.723 0.736 0.720 0.768 0.741 0.699 0.743 Direct flow with CPC 0.742 0.670 0.703 0.735 0.725 0.736 0.723 0.702 0.686 0.697 0.684 0.731 0.706 0.667 0.704 Table 16. Ranking of the twelve alternatives according to the Impact Index obtained for the different weight sets. Domestic WHS Weight sets for the sensitivity analysis original (1c) (1'a) (2b) (2'a) (3a) (3'a) (4a) (4'a) (5a) (5'a) (6a) (6'a) (7a) (8a) Convent. Natural gas 1 1* 3* 1 1* 1* 3* 2* 4 3 4 3* 4 6 3 Electric water heater 12 10 12 12 12 12 12 12 12 12 12 12 12 12 12 Solar + natural gas-fired condensing boiler Flat plate Harp 3* 3* 2* 3* 3* 3* 2* 3* 2* 2* 2* 2* 2* 2* 2* Serpentine 2* 2* 1* 2* 2* 2* 1* 1* 1* 1* 1* 1* 1* 1* 1* Evacuated tube Heat pipe 6 8 6 6 6 6 6 6 6 6 6 6 6 5 6 Direct flow 5 7 5 5 5 5 5 5 5 5 5 5 5 4 5 Direct flow with CPC 4 4 4 4 4 4 4 4 3 4 3 4 3 3 4 Solar + electric water heater Flat plate Harp 8 6 8 8 8 8 8 8 8 8 8 8 8 8 8 Serpentine 7 5 7 7 7 7 7 7 7 7 7 7 7 7 7 Evacuated tube Heat pipe 11 12 11 11 11 11 11 11 11 11 11 11 11 11 11 Direct flow 10 11 10 10 10 10 10 10 10 10 10 10 10 10 10 Direct flow with CPC 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 * When the difference between the first and second position and second and third position is less than 0.01 impact units. As can be deduced from the tables, with slight changes in the importance of the criteria (weights assigned), solar WHS appear to be overall as good as or better than conventional WHS in 13 out of 14 cases due to their reduced energy consumption and GHG emissions, despite being more expensive, occupying more space and using more materials. This result was achieved with the weight sets presented in Table 14, with the exception of weight set (2b). For example, by reducing the importance assigned to the annual cost by 10%, or to the floor space used by 5%, or to the material consumption by
32 [22] Shaddel M, Shokouhian M. Feasibility of solar thermal collectors usage in dwelling apartments in Mashhad, the second megacity of Iran. Renew Sustain Energy Rev 2014;39:1200–7. [23] Bessa VMT, Prado RTA. Reduction of carbon dioxide emissions by solar water heating systems and passive technologies in social housing. Energy Policy 2015;83:138–50. [24] Cassard H, Denholm P, Ong S. Technical and economic performance of residential solar water heating in the United States. Renew Sustain Energy Rev 2011;15:3789- 3800. [25] Friedrich Ferrer PA. Average economic performance of solar water heaters for low density dwellings across South Africa. Renew Sustain Energy Rev 2017;76:507–15. [26] Martín-Gamboa M, Iribarren D, García-Gusano D, Dufour J. A review of life-cycle approaches coupled with data envelopment analysis within multi-criteria decision analysis for sustainability assessment of energy systems. J Clean Prod 2017;150:164- 74. [27] Wang J-J, Jing Y-Y, Zhang C-F, Zhao J-H. Review on multi-criteria decision analysis aid in sustainable energy decision-making. Renew Sustain Energy Rev 2009;13:2263– 78. [28] Troldborg M, Heslop S, Hough RL. Assessing the sustainability of renewable energy technologies using multi-criteria analysis: Suitability of approach for national-scale assessments and associated uncertainties. Renew Sustain Energy Rev 2014;39:1173- 84. [29] Stein EW. A comprehensive multi-criteria model to rank electric energy production technologies. Renew Sustain Energy Rev 2013;22:640-54. [30] Cavallaro F. Multi-criteria decision aid to assess concentrated solar thermal technologies. Renew Energy 2009;34:1678-85. [31] Nixon JD, Dey PK, Davies PA. Design of a novel solar thermal collector using a multi-criteria decision-making methodology. J Clean Prod 2013;59:150-9. [32] de la Fuente A, Armengou J, Pons O, Aguado A. Multi-criteria decision-making model for assessing the sustainability index of wind-turbine support systems: application to a new precast concrete alternative. J Civ Eng Manag ‘in press’;1-10.
33 [33] Keeney RL, Raiffa H. Decisions with multiple objectives: Preferences and value tradeoffs. New York: Wiley; 1976. [34] Casanovas-Rubio M, 2014. Metodología para la evaluación y seguimiento de procedimientos constructivos de forma sostenible e integrada. Doctoral Thesis Supervised by Gonzalo Ramos. Universitat Politècnica de Catalunya, Barcelona. [35] Hallowell MR, Gambatese JA. Qualitative Research: Application of the Delphi Method to CEM research. J Constr Eng Manag 2010;136(1):99-107. [36] Abd-ur-Rehman HM, Al-Sulaiman FA. Optimum selection of solar water heating (SWH) systems based on their comparative techno-economic feasibility study for the domestic sector of Saudi Arabia. Renew Sustain Energy Rev 2016;62:336-49. [37] Roviras J, Sarrablo V, Casanovas M, Armengou J. Architectural integration of energy solar colectors made with ceramic materials and suitable for the Mediterranean climate. Informes de la Construcción 2016;68(544):43-55. [38] Pablo-Romero MP, Sánchez-Braza A, Pérez M. Incentives to promote solar thermal energy in Spain. Renew Sustain Energy Rev 2013;22:198–208. [39] Spain. Orden FOM/1635/2013, de 10 de septiembre, por la que se actualiza el Documento Básico DB-HE "Ahorro de Energía", del Código Técnico de la Edificación, aprobado por Real Decreto 314/2006, de 17 de marzo. Boletín Oficial del Estado 2013;219:67137-209. [40] Generalitat de Catalunya. DECRET 21/2006, de 14 de febrer, pel qual es regula l’adopció de criteris ambientals i d’ecoeficiència en els edificis. Diari Oficial de la Generalitat de Catalunya 2006;4574:7567-70. [41] Ajuntament de Barcelona. Modificació integral de l’annex sobre captació solar tèrmica de l’Ordenança general de medi ambient urbà i dels títols VI i IX. Butlletí Oficial de la Província de Barcelona 2006;62:16-22. [42] Sancho JM, Riesco J, Jiménez C, Sánchez de Cos MC, Montero J, López M. Atlas de Radiación Solar en España utilizando datos del SAF de Clima de EUMETSAT. Gobierno de España; 2012. Retrieved from: http://www.aemet.es/documentos/es/serviciosclimaticos/datosclimatologicos/atlas_radi acion_solar/atlas_de_radiacion_24042012.pdf [accessed 31.01.17]
34 [43] Zainine MA, Mezni T, Dakhlaoui MA, Guizani A. Energetic performance and economic analysis of a solar water heating system for different flow rates values: A case study. Sol Energy 2017;147:164–80. [44] Gobierno de España. Factores de emisión de CO2 y coeficientes de paso a energía primaria de diferentes fuentes de energía final consumidas en el sector de edificios en España. Madrid: Gobierno de España; 2014. Retrieved from: http://www.minetad.gob.es/energia/desarrollo/EficienciaEnergetica/RITE/Reconocidos/ Reconocidos/Otros%20documentos/Factores_emision_CO2.pdf [accessed 31.01.17]