Development of a generic OTS of an FCC unit and fractionator column

Venegas Montañez, Rodrigo Mariano

Abstract

Aquest treball de fi de màster es centra en el desenvolupament d'un simulador d'entrenament d'operadors (“Operator Training Simulator”, OTS) genèric per a una unitat de craqueig catalític fluïditzat (“Fluid Catalytic Cracking”, FCC) i una columna fraccionadora. El seu objectiu és proporcionar un entorn segur i controlat perquè els operadors puguin comprendre el funcionament de la unitat i el comportament en diversos escenaris operatius o malfuncions d'equips. L'OTS es va construir a partir d'una simulació dinàmica existent en Aspen HYSYS, a la qual se li van fer diverses modificacions incloent la sintonització dels llaços de control i el modelatge d'unitats auxiliars com a límits del sistema. Addicionalment, es va implementar un sistema instrumentat de seguretat (SIS) capaç de respondre automàticament en cas de condicions extremes o anormals garantint la seguretat dels operadors i equips. L'estabilitat i fidelitat del model van ser provades sota escenaris operatius comuns com ara variacions en el flux i residu de carboni Conradson (CCR) a l'alimentació. De la mateixa manera, es va avaluar la resposta del SIS davant de dues malfuncions: una sortida bloquejada a la part superior de la columna fraccionadora i la falla del transmissor del controlador de temperatura del reactor. El model va demostrar ser capaç de reproduir amb precisió la dinàmica del sistema i portar la planta a un estat segur quan fos necessari. El producte final és un OTS genèric capaç de reproduir el comportament d'una planta FCC sota condicions diferents, el qual és una eina valuosa per a la formació d'operadors, l'optimització del rendiment de la unitat i el diagnòstic de problemes operatius en un entorn controlat.

Full text

FINAL MASTER THESIS Master’s Degree in Chemical Engineering DEVELOPMENT OF A GENERIC OTS OF AN FCC UNIT AND FRACTIONATOR COLUMN Report and Annex Author: Rodrigo Venegas Supervisor: Antonio Espuña Department EEBE Company tutor: Miquel Àngel Alos Call: 2023, June Development of a Generic OTS of an FCC Unit and Fractionator Column 1 Abstract This master’s thesis focuses on the development of a generic Operator Training Simulator (OTS) for a Fluid Catalytic Cracking (FCC) unit and fractionator column. It aims to provide a safe and controlled environment for operators to gain an understanding of the unit and its behavior under various operating scenarios and equipment malfunctions. The OTS was built from an existing dynamic simulation in Aspen HYSYS, to which several modifications were made including the tuning of control loops and the modeling of auxiliary units as process boundaries. Additionally, a safety instrumented system (SIS) was implemented to respond automatically in the case of extreme or abnormal conditions to guarantee the safety of the operators and equipment. The stability and fidelity of the model were assessed under common operating scenarios such as variations in the feed rate and Conradson Carbon Residue (CCR). Similarly, the response of the SIS was evaluated under two process malfunctions: a blocked outlet in the fractionator top and a transmitter failure in the reactor riser temperature controller. The model proved to be able to accurately reproduce the dynamics of the system and bring the plant to a safe state when necessary. The final product is a comprehensive generic OTS capable of reproducing the behavior of an FCC plant under different conditions, which serves as a valuable tool for operator training, optimizing unit performance, and diagnosing operational issues in a controlled environment. Key words: Operator Training Simulator (OTS), Fluid Catalytic Cracking (FCC), Dynamic simulation, Operating scenarios, Process malfunctions, Safety instrumented system Memory 2 Resum Aquest treball de fi de màster es centra en el desenvolupament d'un simulador d'entrenament d'operadors (“Operator Training Simulator”, OTS) genèric per a una unitat de craqueig catalític fluïditzat (“Fluid Catalytic Cracking”, FCC) i una columna fraccionadora. El seu objectiu és proporcionar un entorn segur i controlat perquè els operadors puguin comprendre el funcionament de la unitat i el comportament en diversos escenaris operatius o malfuncions d'equips. L'OTS es va construir a partir d'una simulació dinàmica existent en Aspen HYSYS, a la qual se li van fer diverses modificacions incloent la sintonització dels llaços de control i el modelatge d'unitats auxiliars com a límits del sistema. Addicionalment, es va implementar un sistema instrumentat de seguretat (SIS) capaç de respondre automàticament en cas de condicions extremes o anormals garantint la seguretat dels operadors i equips. L'estabilitat i fidelitat del model van ser provades sota escenaris operatius comuns com ara variacions en el flux i residu de carboni Conradson (CCR) a l'alimentació. De la mateixa manera, es va avaluar la resposta del SIS davant de dues malfuncions: una sortida bloquejada a la part superior de la columna fraccionadora i la falla del transmissor del controlador de temperatura del reactor. El model va demostrar ser capaç de reproduir amb precisió la dinàmica del sistema i portar la planta a un estat segur quan fos necessari. El producte final és un OTS genèric capaç de reproduir el comportament d'una planta FCC sota condicions diferents, el qual és una eina valuosa per a la formació d'operadors, l'optimització del rendiment de la unitat i el diagnòstic de problemes operatius en un entorn controlat. Paraules clau: Simulador d'entrenament d'operadors (OTS), Craqueig catalític fluïditzat (FCC), Simulació dinàmica, Escenaris operatius, Malfuncions, Sistema instrumentat de seguretat Development of a Generic OTS of an FCC Unit and Fractionator Column 3 Resumen Este trabajo de fin de máster se centra en el desarrollo de un simulador de entrenamiento de operadores (“Operator Training Simulator”, OTS) genérico para una unidad de craqueo catalítico fluidizado (“Fluid Catalytic Cracking”, FCC) y una columna fraccionadora. Su objetivo es proporcionar un entorno seguro y controlado para que los operadores puedan comprender el funcionamiento de la unidad y su comportamiento en diversos escenarios operativos o malfunciones de equipos. El OTS se construyó a partir de una simulación dinámica existente en Aspen HYSYS, a la cual se le hicieron varias modificaciones incluyendo la sintonización de los lazos de control y el modelado de unidades auxiliares como límites del sistema. Adicionalmente, se implementó un sistema instrumentado de seguridad (SIS) capaz de responder automáticamente en caso de condiciones extremas o anormales garantizando la seguridad de los operadores y equipos. La estabilidad y fidelidad del modelo fueron probadas bajo escenarios operativos comunes tales como variaciones en el flujo y residuo de carbono Conradson (CCR) en la alimentación. De igual manera, se evaluó la respuesta del SIS frente a dos malfunciones: una salida bloqueada en la parte superior de la columna fraccionadora y la falla del transmisor del controlador de temperatura del reactor. El modelo demostró ser capaz de reproducir con precisión la dinámica del sistema y llevar la planta a un estado seguro cuando fuera necesario. El producto final es un OTS genérico capaz de reproducir el comportamiento de una planta FCC bajo distintas condiciones, el cual es una herramienta valiosa para la formación de operadores, la optimización del rendimiento de la unidad y el diagnóstico de problemas operativos en un entorno controlado. Palabras clave: Simulador de entrenamiento de operadores (OTS), Craqueo catalítico fluidizado (FCC), Simulación dinámica, Escenarios operativos, Malfunciones, Sistema instrumentado de seguridad Memory 4 Appreciations I would like to express my gratitude to my family for their unconditional support throughout my journey towards the completion of my master’s thesis. Thank you for your sacrifices and for making this possible. Development of a Generic OTS of an FCC Unit and Fractionator Column 5 Glossary ADU: Atmospheric Distillation Unit ESD: Emergency Shutdown FCC: Fluid Catalytic Cracking HAZOP: Hazard and Operability HCO: Heavy cycle oil HDS: Hydrodesulfurization HMI: Human-Machine Interface HP: High Pressure LCO: Light cycle oil MP: Middle Pressure OTS: Operator Training Simulator PFD: Process Flow Diagram PV: Process variable SIS: Safety Instrumented System SP: Setpoint OP: Output VDU: Vacuum Distillation Unit VGO: Vacuum Gasoil YSR: Yield Shift Reactor Memory 6 Development of a Generic OTS of an FCC Unit and Fractionator Column 13 The feed to the FCC unit can come from different units of a refinery, it being residuum from the atmospheric distillation unit (ADU), residuum from the vacuum distillation unit (VDU), or vacuum gas oil (VGO). The latter is the most widely used feed for this unit, as it is commonly located after the VDU as shown in Figure 2.2. The FCC products are blended with products from other units to produce gasoline, gasoil, diesel, and heavy fuel oil (2). Figure 2.2. A typical refinery scheme with an FCC unit (2) Figure 2.3 shows a simplified scheme of the reactor-regenerator-fractionator column system. In the FCC reactor, the catalyst is fed as a fine powder at a high temperature (>650ºC) coming from the regenerator, in such a way that when it comes into contact with the liquid VGO feed, the feed is vaporized, and the catalyst is able to move as a fluid through the reactor. The gas products that result from the cracking reactions are sent to the main fractionator to be separated as different hydrocarbon cuts (naphtha, LCO, HCO, slurry/decant oil), while the spent catalyst is sent to the regenerator. In the regenerator, the coke deposits in the catalyst are burned off by combustion with air and the regenerated catalyst is sent back to the reactor. Memory 14 Figure 2.3. Simplified scheme of an FCC unit showing the reactor, regenerator, and fractionator column (5) 2.1. Reactions and Catalysts The feed to the FCC reactor is a mixture of hydrocarbons of varying length, molecular weight, and molecular structure. Therefore, there is a large variety of reactions that occur during catalytic cracking of VGO, which can be grouped as follows: ● Paraffins: Carbon-carbon bond scission into a lighter paraffin and an olefin; they tend to break towards the center of the chain forming C3 and C4 products ● Olefins: The most reactive; they rapidly undergo isomerization, hydrogen transfer, polymerization, and aromatics; they are considered to be the precursors of coke formation ● Cycloparaffins or naphthenes: Undergo ring and chain rupture to yield olefins and paraffins; they produce aromatic hydrocarbons after cracking ● Aromatics: Most are inert or crack slowly, however when reacting they produce coke This variety of simultaneous reactions yields a product that is also a mixture of many different hydrocarbons, which then are separated into different cuts in the fractionator to obtain naphtha, LCO, HCO, and decant oil (3). Coke formation and deposition over the catalyst during catalytic cracking leads to the reduction of the catalyst activity and thus a lower product yield, which is why the FCC reactor is always coupled with a regenerator to burn the coke off the catalyst by mixing it with air. The Conradson Carbon Development of a Generic OTS of an FCC Unit and Fractionator Column 15 Residue (CCR) is a measurement of the coke yield of a hydrocarbon mixture when completely distilled and is commonly used as an indicator of the coke yield in an FCC unit (6). The mechanism of coke formation is not completely known; however, a general reaction sequence can be established as follows (7): Olefins → Oligomers → Naphthenes → Aromatics → Coke The most common catalysts used in FCC units are zeolites, as these reactions are acid catalyzed. In particular, the modified zeolite Y or faujasite is used due to its higher silica-alumina ratio, which confers a high thermal stability. This variety of zeolite increases the yield of naphtha, which is generally the most valuable FCC product (8). Additionally, it is important that the catalyst has a high resistance to thermal shocks and to impact, as the transport at high temperatures between the reactor and the regenerator as well as the movement of the particles inside the cyclones can cause catalyst attrition and therefore the loss of activity (9). 2.2. Reactor and regenerator internals The internal design of the reactor and the regenerator in an FCC unit is crucial to the performance of the unit. A simplified scheme of the equipment internals is shown in Figure 2.4. The reactor contains a long standpipe at the base, known as the riser. The reactor feed and hot regenerated catalyst enter the reactor riser, where steam is added to atomize the feed for a better contact. All the cracking reactions take place in the riser, and then the products and catalyst enter the top of the reactor which is known as the stripping and disengaging section. In this section, more steam is added to remove the reaction products from the catalyst. Then, the gas-solid mixture enters the reactor cyclones and the catalyst deposits at the bottom of the reactor while the gas products exit at the top and are sent to the fractionator. The flow of spent catalyst to the regenerator is controlled by a slide valve, which can also function as a level control valve. In the regenerator, hot air is introduced through air spargers or distributors to allow for better contact with the solid particles in the bottom of the vessel. Combustion reactions take place in the regenerator as the coke is burned off from the solid catalyst particles, and the gas-solid mixture enters a series of cyclones for its separation. The flue gases are sent to gas treatment units, while the regenerated catalyst deposits at the bottom forming the dense phase of the regenerator, from which it is transported to the bottom of the reactor riser to meet the feed and repeat the cycle. The flow of hot regenerated catalyst to the reactor is controlled by a slide valve, which acts as the riser temperature control valve (2). Memory 16 Figure 2.4. Reactor-regenerator system (10) The design of the internals of the reactor and regenerator, namely the feed nozzles, riser, and cyclones, has a significant impact on the reaction yield and catalyst separation efficiency. The feed nozzles must be designed in such a way that they are able to atomize the feed to provide an optimal contact between the reactor and the catalyst, and the design of the riser must also ensure that this contact is maintained throughout the riser to achieve the desired yield. The reactor and regenerator cyclones play a key role in the separation of the catalyst from the gas products and flue gases respectively, and their design must assure a high-efficiency separation to avoid the loss of catalyst through gas streams. Finally, it is important that the circulation of the catalyst between both vessels is maintained at all times as this controls the reaction temperature and the pressure build-up in the system, therefore the design of the equipment must provide a good transport of the catalyst (11). 2.3. Control Parameters There are several control parameters that must be considered when operating an FCC unit. These are generally related to pressure, temperature, level, and flow control loops, and are located in different areas of the unit. Therefore, it is important to highlight the most important process parameters in this unit and how these are controlled. 2.3.1. Reactor riser temperature The temperature in the reactor riser is a key process parameter in an FCC unit, since it dictates the conversion of the feed into naphtha, LCO, HCO, decant oil, and coke. The reactions usually take place in the riser at temperatures between 520-550ºC. At lower temperatures, the cracking reactions do not Development of a Generic OTS of an FCC Unit and Fractionator Column 17 occur at the desired rate or at all, and at higher temperatures the coke formation is increased, while that of naphtha is decreased. Therefore, the riser temperature must be controlled at all times during operation. This is achieved by the action of a slide valve that can be either the one transporting catalyst to or from the regenerator. The riser temperature depends on the circulation rate of the hot catalyst between the reactor and regenerator, and it is controlled by opening or closing the slide valve to increase or decrease it as required (12). 2.3.2. Reactor-Regenerator pressure differential Another key control parameter in an FCC unit is the pressure differential between the reactor and the regenerator, the latter being usually at a higher pressure. This parameter is the driving force for the circulation of the catalyst between both vessels, and as such must be maintained for the process to run smoothly (12). The pressure differential setpoint is usually around –0.15 to 0.15 bar, and it is controlled by a pressure control valve at the flue gas outlet of the regenerator or by the flue gas compressors. It is of great importance that this parameter is controlled during the operation of the unit because not only does it guarantee the circulation of the catalyst for the reactions to occur, but it also helps to avoid the formation of hotspots inside the vessels as well as possible damage to equipment due to a high pressure difference (13). 2.3.3. Fractionator temperature and pressure profiles Finally, in the fractionator section of the FCC unit it is important to constantly monitor both the temperature and pressure profiles along the column, as these parameters determine the equilibrium in each stage and therefore the composition of the different cuts obtained. As this fractionator usually does not contain a reboiler, the temperature at the bottom is controlled by the reflux of the bottoms hydrocarbons to the sump of the column, while the temperature at the top is controlled by acting on the reflux rate from the top condenser. Additionally, the temperature at intermediate stages can be adjusted by manipulating the several pumparounds in the column. On the other hand, the pressure at the top of the column is governed by the pressure in the reflux drum, which in turn is controlled by a pressure valve at the gas outlet or by the wet gas compressors (14). 2.4. HAZOP Analysis A hazard and operability (HAZOP) analysis of the FCC unit was performed to define the operating scenarios and malfunctions that the OTS must be capable of handling and what the response of the SIS should be to mitigate the effects of these process upsets. This HAZOP analysis is shown in Table 2.1. The main process upsets considered were variations in the flow, temperature, and pressure of the unit, as well as a change in the feed composition. Memory 18 Table 2.1. HAZOP analysis of the FCC unit In most cases listed above, the deviations result in a pressure or temperature build-up inside the reactor-regenerator and column system that represent a critical scenario for the equipment and for the operator. Therefore, the main objective of the safeguards is to relief the pressure in the system by opening pressure safety valves or blowdown valves, as well as cutting the hot catalyst flow in the reactor-regenerator. Deviation Causes Consequences Safeguards Less Flow Upset in upstream processes Riser temperature increases, feed to fractionator decreases Spent catalyst slide valve opens fully, the system is isolated at high riser temperature alarm More Flow Upset in upstream processes Riser temperature decreases, feed to fractionator increases Spent catalyst slide valve closes fully, the system is isolated at low riser temperature alarm, column pressure safety valve opens at high pressure alarm No Flow Upset in upstream processes. feed pump failure High reactor riser temperature, feed to the fractionator is cut Reactor/regenerator system is isolated, catalyst flow to reactor is stopped More Pressure Blocked outlet in fractionator, compressor trip Pressure differential control valve closes, top fractionator pressure control valve opens Column pressure safety valve opens, fractionator system trips at high pressure alarm, reactor blowdown valve opens at high pressure alarm Less Pressure Less VGO feed, low riser temperature Pressure differential control valve opens Fractionator system trips at low pressure alarm Less Temperature No catalyst circulation, VGO flow is too high, air flow to regenerator stops, temperature transmitter misreading closes the regenerated catalyst slide valve Regenerated catalyst slide valve opens, cracking reactions decrease Spent catalyst slide valve closes fully, the system is isolated at low riser temperature alarm More Temperature Low VGO flow to reactor, coke accumulation in regenerator, temperature transmitter misreading opens the regenerated catalyst slide valve Regenerated catalyst slide valve closes Spent catalyst slide valve opens fully, the system is isolated at high riser temperature alarm More pressure differential Low pressure in reactor, high pressure in regenerator, less flow to reactor Pressure differential control valve opens, spent catalyst flow decreases The system is isolated and regenerated catalyst slide valve closes fully Less pressure differential High pressure in reactor, low pressure in regenerator, fractionator system trip Pressure differential control valve closes, regenerated catalyst flow decreases Reactor pressure safety valve opens, blowdown valve opens at high reactor pressure alarm More CCR Change in feed quality Higher temperature in reactor and regenerator, regenerated catalyst slide valve closes, incomplete combustion in regenerator Spent catalyst slide valve opens fully, the system is isolated at high riser temperature alarm Development of a Generic OTS of an FCC Unit and Fractionator Column 19 3. Model Description 3.1. Feed separation and preheating The VGO feed to the FCC reactor must be preheated to around 380ºC to achieve optimal conditions in the riser, therefore a fired heater is required. Figure 3.1 shows the process flow diagram (PFD) for this area of the process. VGO from the VDU is fed to separator 24-V-001 to remove any water from the line. The liquid hydrocarbons are sent to separator 24-V-002, where VGO from coking units is fed. This vessel directs any excess gases to the flare system, and the hydrocarbon liquids enter the shell of the heat exchanger 24-E-001. The feed is heated up to 280ºC by the hot bottoms from the fractionator and then enters the fired heater 24-F-001. The flow controllers 24-FIC-012/013 ensure a constant feed to the system, which is set at 150 m3/h. The fired heater 24-F-001 contains a combustion chamber that receives air and fuel gas at a ratio of 2.2:1 and where combustion reaction takes place. Then, the combustion products enter the radiation and convection zones to heat up the feed and exit through the flue gas stack. The temperature of the VGO that exits 24-F-001 and enters the reactor is controlled by 24-TIC-012, which regulates the flow of fuel gas required. Figure 3.1. PFD for the Feed separation and preheating area 3.2. Reactor and Regenerator The PFD for the Reactor and Regenerator area of the FCC unit is shown in Figure 3.2. Memory 20 3.2.1. Reactor Due to the complexity of the reactions involved during catalytic cracking, the FCC reactor was modelled as a yield shift reactor (YSR). This type of reactor is appropriate for complex reactions with various products and helps to improve the performance of the dynamic model by reducing the computational demand of this operation. The YSR receives as input a matrix of the expected products yields under various conditions such as temperature, pressure, catalyst activity, etc., from which it is able to calculate the yield as these conditions change during operation (15). The key process parameters sent to the YSR were feed temperature, reaction temperature, catalyst activity, and stripping steam feed rate. The data matrix that was introduced in the YSR block was obtained from real data from an operating FCC plant, indicating the composition of the reaction products stream under various operating conditions. As detailed in section 2.1, the cracking reactions that occur in an FCC unit are overly complex and generate a variety of products. In order to facilitate the reaction calculations, these were simplified as: 𝑉𝐺𝑂 → 𝑁𝑎𝑝ℎ𝑡ℎ𝑎 + 𝐿𝐶𝑂 +𝐻𝐶𝑂 + 𝐷𝑒𝑐𝑎𝑛𝑡 𝑂𝑖𝑙 + 𝐶𝑜𝑘𝑒 + 𝐿𝑖𝑔ℎ𝑡 𝐸𝑛𝑑𝑠 (Eq. 1.1) This way, all the possible reaction products are lumped into six groups: naphtha, LCO, HCO, decant oil, coke, and light ends. The feed to the reactor riser 24-R-001 is made up of preheated VGO, hot catalyst from the regenerator 24-R-002, and atomizer steam from the steam generation unit. When the liquid feed comes into contact with the hot regenerated catalyst, it is instantly evaporated. The temperature in the riser is one of the most important parameters in the reactor system as it has a direct influence on the reaction products and yields. This temperature is set at 535ºC and controlled by 24-TIC-031, which regulates the hot catalyst flow from the regenerator to the reactor to meet the desired setpoint. It is at this point where the cracking reactions take place, converting the VGO into light hydrocarbons, naphtha, LCO, HCO, decant oil, and coke. After the riser section, stripping steam is added to the system to remove any unreacted hydrocarbons from the catalyst. Additionally, naphtha can be recycled from the fractionator to the reactor as required to improve the yield of high-octane hydrocarbons and reduce the formation of coke, while helping to control the temperature and avoid the formation of hot spots in the reactor (16). The catalyst level inside the reactor is controlled by acting on 24-LCV-005. The reaction products exit at the top of the reactor and are sent to the fractionator 24-C-001 to be separated into different cuts, while the spent catalyst is sent to the regenerator 24-R-002. Development of a Generic OTS of an FCC Unit and Fractionator Column 21 3.2.2. Regenerator The regenerator 24-R-002 is fed with spent catalyst and hot combustion air. In this vessel, the combustion of coke into CO, CO2, H2S and SO2 takes place, and the catalyst is regenerated. The flue gases are directed to the steam generation unit, while the regenerated catalyst is sent back to the riser in 24-R-001. As mentioned before, the catalyst flow from the regenerator to the reactor is controlled by 24-TIC-031 to achieve the desired temperature setpoint in the reactor riser. As detailed in section 2.1.2, another key control parameter in this unit is the pressure difference between 24-R-001 and 24-R-002, which is controlled by 24-PDIC-002 acting on 24-PDCV-002. This control valve is usually located at the outlet of the steam generation unit, however, as this auxiliary unit is outside of the scope of this work this control valve is placed at the outlet of the regenerator for simulation purposes. Figure 3.2. PFD for the Reactor and Regenerator area 3.3. Fractionator The fractionator 24-C-001 is a distillation column with 39 stages, numbered from bottom to top. The feed is made up of the reaction products from 24-R-001 and stripping steam to the column sump. Additionally, there are recycle lines at various stages to optimize the recovery and achieve the desired properties in each cut by adjusting of the temperature profile in the column, as well as to ensure an efficient energy utilization. These recycle lines include the top reflux system for the distilled vapors, an LCO reflux to stage 25, HCO reflux to stage 14, and a bottoms reflux to the column sump. In order to optimize the recovery of LCO, an LCO stream is extracted from stage 21 and sent to a six-stage side Memory 22 stripper (24-C-002). The bottoms liquids of 24-C-002 enter a reboiler, then the vapors flow through the column and are fed back to 24-C-001 at stage 22. The PFD for the fractionator is shown in Figure 3.3. Figure 3.3. PFD for the Fractionator 3.3.1. Reflux System The vapors from 24-C-001 are cooled and condensed by the air cooler 24-AC-002 and the heat exchanger 24-E-002 before entering the reflux drum 24-V-003. The pressure in this vessel is controlled at 0.6 barg by 24-PIC-019 transferring the hydrocarbon vapors to the gas compression unit, while any water appearing in the separator’s boot is sent to the water treatment plant. The hydrocarbon reflux to 24-C-001 controls the top temperature of the column at 135ºC by the action of 24-TIC-039. The remaining liquid naphtha can be sent either to storage or to the reactor if reprocessing is required. 3.3.2. LCO Cycle LCO is extracted from stage 21 of 24-C-001 and enters 24-C-002, a side stripper with six stages whose purpose is to maximize the recovery of liquid hydrocarbons and remove any impurities from the Development of a Generic OTS of an FCC Unit and Fractionator Column 29 Figure 4.7. Fractionator Bottoms Cycle screen Figure 4.8. Scenarios & Malfunctions screen Additionally, all the controllers contain a faceplate like the one shown in Figure 4.9, which pops up when clicking over them. This custom faceplate contains all the key information of the controllers such as the value of the process variable (PV), setpoint (SP), and output (OP), the control mode (manual, automatic, or cascade), and the status of the alarms. The operator is able to manipulate the control Memory 30 parameters (Kp, Ti, Td) of the controller through this faceplate, which allows them to evaluate the behavior of the control loops under different control parameters. Figure 4.9. Faceplate for controller 24-FIC-019 Finally, the OTS contains six screens dedicated to the alarms of the SIS, shown in Figures 4.10-4.15, which were based on the HAZOP analysis previously shown in Table 2.1 of Section 2.4. The process upsets mentioned in the “Causes” column of Table 2.1 were included in the dynamic model as flow, pressure, and temperature alarms and added to the “Cause” column of the SIS screens. On the other hand, the consequences of each deviation listed in Table 2.1 were added to the “Effect” column of these screens. In addition to the causes and effects listed in Table 2.1, safeguards for the operation of the pumps were included in the SIS, particularly that if the level in the upstream vessel is too low, the pumps trip and the inlet valves close to prevent damage to the equipment due to insufficient or reverse flow. Figure 4.10. Screen SIS-01 Development of a Generic OTS of an FCC Unit and Fractionator Column 31 Figure 4.11. Screen SIS-02 Figure 4.12. Screen SIS-03 Memory 32 Figure 4.13. Screen SIS-04 Figure 4.14. Screen SIS-05 Development of a Generic OTS of an FCC Unit and Fractionator Column 33 Figure 4.15. Screen SIS-06 4.2. Scenarios and Malfunctions The generic OTSs provided by Inprocess Technology and Consulting Group contain two preconfigured scenarios and malfunctions, which are activated from the corresponding screen shown in Figure 4.8. For this OTS, based on the HAZOP analysis performed in section 2.4, the two operating scenarios chosen were a ramp-down and ramp-up of the VGO feed and an increase in the feed CCR, while the two malfunctions selected were a blocked outlet at the fractionator top and the failure of the temperature transmitter of 24-TIC-031, which controls the reactor riser temperature. The response of the system to these operating scenarios and process malfunctions are described below. 4.2.1. Scenario 1: Feed Ramp-down and Ramp-up For this scenario, the feed to the reactor was decreased from 150 m3/h to 130 m3/h by reducing the setpoint of the flow controllers 24-FIC-012 and 24-FIC-013 entering the fired heater. Once the main controllers stabilized, the feed was increased to 150 m3/h. The objective of this is to evaluate the stability of the system upon changes in the VGO feed rate, which in a refinery would be expected to experience some fluctuations due to the operation of upstream units. Figure 4.16 shows the evolution of the main control variables in the unit during the ramp-down and ramp-up. The system proved to be stable upon feed rate changes and the control loops showed a fast and adequate response. Memory 34 Figure 4.16. Evolution of the main control parameters during ramp-down and ramp-up It is worth mentioning that the behavior of the system shown in Figure 4.16 corresponds to its automatic response governed by the controllers, without any operator interference. In reality, when the feed to the reactor and therefore the feed to the fractionator decreases significantly, the operator must act and manipulate some parameters such as the pumparound feed rate to maintain the desired temperature profile and ensure an efficient separation in the column. 4.2.2. Scenario 2: CCR increase in feed In this scenario, the CCR of the VGO feed to the reactor was increased from 3 to 4%. As the CCR of the feed increases, more coke is generated in the reactor and deposited over the catalyst. Then, coke starts building up inside the regenerator, causing the combustion reactions to increase and producing more heat which leads to elevated regenerator temperatures that can be observed in 24-TI-025. As hotter regenerated catalyst is sent to the reactor, it produces an increase in the riser temperature which is then controlled by 24-TIC-031 by reducing the regenerated catalyst flow. Although the riser temperature is controlled automatically, the increased CCR of the feed will inevitably lead to a coke build-up over the catalyst due to incomplete combustion if the operator does not take any action. The efficiency of the coke combustion is monitored by the analyzers 24-AI-001 and 24-AI- 002, which measure the CO and O2 content in the flue gases of the regenerator, respectively. For CO, this value should be kept under 50 ppm and close to 40 ppm to control the emissions of the process, while for O2 it must be around 3 to 5% to ensure an efficient and complete combustion of coke (17). As more coke deposits over the catalyst, its incomplete combustion produces more CO and there is fewer excess O2 in the flue gases. The operator must be able to identify these variations in the flue gas composition and recognize the need to increase the air feed to the regenerator by opening 24-FCV- Development of a Generic OTS of an FCC Unit and Fractionator Column 35 025 until the analyzers show the desired CO and O2 content. It is important that this operation is performed gradually as increasing the air feed rate to promote the complete combustion of coke will also increase the catalyst temperature and therefore that of the riser. Figure 4.17 shows the evolution of 24-TI-025, 24-AI-001, 24-AI-002, and 24-FIC-025 when this operating scenario is activated. This plot shows the behavior described before: at first the CO content and the riser temperature increase, while excess oxygen decreases. As the air flow control valve is opened the CO content decreases and excess oxygen increases, while causing temperature peaks in the riser that are quickly controlled by 24-TIC-031. Finally, the CO and O2 content in the flue gases are brought back to the desired thresholds and the reactor system is able to operate under normal conditions avoiding the coke build-up in the regenerator. Annex A2 demonstrates the activation and mitigation of this scenario in the OTS. Figure 4.17. Evolution of the riser temperature (red), flue gas CO (black) and O2 (gray) content, and air feed to regenerator (purple) during the feed CCR increase 4.2.3. Malfunction 1: Blocked Outlet The objective of this malfunction is to simulate the response of the system when the vapor outlet of the fractionator system through 24-PCV-019A becomes blocked and the pressure builds up in the system. In a refinery setting, this may be due to a physical blockage of the valve or piping system or a failure in the downstream wet gas compressor. To mitigate this problem, the operator can reduce the hydrocarbon vapor generation by reducing the VGO feed to the reactor and/or reducing the riser temperature until the pressure ceases to increase or reduce the top column temperature by decreasing the SP of 24-TIC-039 and turning on all the fans Memory 36 in 24-AC-002. When the problem at the outlet is fixed, the operator must gradually close 24-PCV- 019A/B as the feed to the gas compressors is resumed until the pressure is stable. When 24-PIC-019 starts controlling the top pressure, the operator may gradually increase the reactor feed, riser temperature, and column temperature as required. Figure 4.18 shows the behavior of the system when this malfunction is activated and when the operator’s actions are able to mitigate its effect and bring the system back to normal operation after the malfunction is resolved. Annex A3 demonstrates the sequence of actions described. Figure 4.18. Evolution of the riser temperature (red), fractionator top pressure (purple), and vapor feed to fractionator (brown) during the blocked outlet malfunction when corrective measures are taken In case the operator is unable to recognize and mitigate the rapid pressure increase, the automatic ESD (emergency shutdown) response of the SIS will activate to protect the equipment and the operators from extreme conditions. The sequence of events that take place when the ESD is triggered is the following: 1. When the pressure reaches 1.8 barg, the high pressure alarm 24-PAHH-019 will activate the ESD and cut the feed from the reactor to the fractionator. Valve 24-PCV-019A will close and valve 24-PCV-019B will open fully to relieve the pressure in the system by sending the gases to flare. If the pressure goes over 2.0 barg, the pressure safety valve 24-PSV-002 will open. The top reflux to the column and all pumparounds are stopped, and hydrocarbon export is cut. The activation of these alarms and the response of the SIS is shown in Figures 4.19-4.21. Development of a Generic OTS of an FCC Unit and Fractionator Column 37 Figure 4.19. Activation of the high pressure alarm in the top of the fractionator Figure 4.20. Activation of the fractionator ESD signal Memory 38 Figure 4.21. Activation of the fractionator ESD signal 2. As the pressure in 24-R-001 increases due to the closed gas outlet, the reactor pressure will surpass that of the regenerator and prevent the flow of regenerated catalyst to the reactor, activating the low differential pressure alarm. This alarm trips open the blowdown valve 24- BDV-001 and closes the VGO and naphtha feeds to the reactor from 24-F-001 and 24-V-003 respectively, while opening the bypass valve 24-SDV-008 to send the VGO back to storage. When the feed is cut, the high riser temperature alarm closes the regenerated catalyst valve. These alarms and actions be seen in figure 4.22. Figure 4.22. Reactor-regenerator system ESD response 3. As the catalyst flow to the reactor is cut, the level control valve 24-LCV-005 will close and stop the circulation of the catalyst. The steam flow through the reactor is continued to purge any residual hydrocarbons out of the system. 4. The trips in the reactor area will stop the fuel gas feed to 24-F-001 and stop the combustion as shown in Figure 4.23. Development of a Generic OTS of an FCC Unit and Fractionator Column 45 Conclusions This thesis has successfully developed a generic OTS for an FCC unit and its associated fractionator column. The dynamic model was adapted from an existing one, and a SIS was implemented by evaluating the possible upsets that can happen in this unit and the necessary automatic actions that must take place to prevent severe damage to the operators and to the equipment. The OTS was tested under various process upsets and malfunctions: feed rate ramp-down and ramp-up, CCR increase in feed, a blocked outlet in the fractionator top, and a failure in the transmitter of the riser temperature controller. In all cases, the model was able to reproduce the dynamics of the system and control the desired parameters when possible. When the conditions inside the equipment became too extreme or represented a risk to the operators and equipment, the SIS activated and led the plant to a safe state by isolating the different areas to prevent severe damage during operation, thereby demonstrating that it was correctly implemented. Even though this OTS contains only two scenarios and two malfunctions setup by default, the dynamic model and the SIS are capable of reproducing and controlling the behavior of the plant under any other conditions that can take place during operation or that the instructor wishes to emulate. This generic OTS is a very valuable product for refineries, as its use can improve their safety, reliability, and profitability by training the operators to be prepared for any operating scenario. Most importantly, it is a safe and controlled environment in which the operator can achieve a comprehensive understanding of the process through the manipulation of variables and parameters without ever risking the production of the plant, which makes it an invaluable asset for any refinery. Memory 46 Economic evaluation In this section, the economic evaluation of the development of the OTS is performed considering the engineering cost of the software used, the person-hours dedicated to creating this OTS, and an approximate selling price of a generic OTS. Engineering cost From the point of view of the company developing the OTS, this project does not involve an additional cost regarding new software or licenses. The proprietary software used for creating the OTS was already developed, and no new Aspen HYSYS licenses were purchased for this project. These can be considered as fixed costs for the company and are as such not considered for the economic evaluation of this project. Labor cost This OTS was developed by a chemical engineer over the span of 20 weeks, dedicating about 20 hours per week to this project. Considering a salary of around 30,000 € per year for a 40-hour work week, this gives a labor cost of approximately 5,800 €. Accounting for the need for supervision and advisory during the development of the OTS, this required an average of 4 hours per week for 20 weeks. Considering an approximate salary of 60,000 € per year for a senior chemical engineer, this results in a labor cost of approximately 2,300 € for the duration of this project. In total, this results in a labor cost of 8,100 € for an OTS developed in 20 weeks. Selling price To put a selling price on this product, it is necessary to consider that it being a generic OTS its price is lower than that of a dedicated OTS that exactly replicates the customer’s plant. According to information provided by Inprocess Technology and Consulting group, a generic OTS with the same characteristics as the one developed in this project (with two scenarios and two malfunctions) may be sold for about 80,000 to 100,000 € plus an additional 20% per year for maintenance. Moreover, this generic OTS can potentially be sold to more than a single customer, increasing the expected income from the product The high selling price of an OTS with respect to the engineering and labor costs that it requires is justified by to several reasons: Development of a Generic OTS of an FCC Unit and Fractionator Column 47 ● High-technology software: The development of an OTS requires the use of high-technology software for the process modeling as well as for the connectivity and displays. This is not easily accessible for any company, and therefore this increases the value of the product to be sold. ● Knowledge: A product such as this one must be developed by a well-prepared engineer with simulation experience for the model to represent the dynamics of the system accordingly and to provide a good control over the process. The knowledge and experience that goes into this product must be considered when setting its price. ● Value for the customer: An OTS is designed to provide a highly accurate and reliable response of the system under various process upsets, which can significantly improve the safety, reliability, and profitability of a refinery by training the operators to be prepared for any operating scenario. It can be difficult to quantify the immediate economic benefits for a refinery, however if we assume that a 50,000 barrels/day refinery makes 10 € per barrel, preventing a day of downtime by having the operators appropriately trained can save the company up to 500,000 € (18). Even when the specific costs and selling price are approximate, a large favorable margin can be observed when developing and selling an OTS of this kind. The highest costs for the company developing the OTS go towards the software and licenses, which are not specifically dedicated to this project but common to many other ones and therefore are fixed costs. The high-technology software used as well as the required knowledge and experience of the development engineer give enough value to this product to justify the relatively high selling price. Nevertheless, refineries are willing to acquire this product because of the invaluable savings that it provides by having the operators prepared for any emergency scenario. Annexes 48 References 1. State-of-the-Art Review of Fluid Catalytic Cracking (FCC). Oloruntoba, Adefarati, Zhang, Yongmin and Hsu, Chang. 15, 2022, Energies. 2. Speight, James G. The Refinery of the Future. OXford : Elsevier, 2011. 3. Gary, James H. and Handwerk, Glenn E. Petroleum Refining: Technology, Economics, and Markets. 6th ed. Boca Raton : CRC Press, 2019. 4. U.S. Chemical Safety and Hazard Investigation Board. FCC Unit Explosion and Asphalt Fire at Husky Superior Refinery. 2022. 5. The Petro Solutions. Fluid Catalytic Cracking Process in Oil Refinery. [Online] 2021. [Cited: May 3, 2023.] https://thepetrosolutions.com/fluid-catalytic-cracking-process-in-oil-refinery/. 6. Energy Insights. Carbon residue. [Online] [Cited: May 18, 2023.] https://www.mckinseyenergyinsights.com/resources/refinery-reference-desk/carbon-residue/. 7. Speight, James. Handbook of Industrial Hydrocarbon Processes. Oxford : Elsevier, 2010. 8. Drobek, Martin and Julbe, Anne. Zeolite Y Type. [book auth.] Enrico Drioli and Lidietta giorno. Encyclopedia of Membranes. Berlin : Springer, 2016. 9. FCC Catalyst Attrition Behavior at High Temperatures. Ghazvini, Saba, Ebrahimi, Ali and Jafarnia, Seyed. 2019, Journal of Particle Science and Technology, Vol. 5. 10. Dynamic modeling and simulation of a Fuidized catalytic cracking process. Part I: Process Modeling. Han, In-Su and Chung, Chang-Bock. 56, 2001, Chemical Engineering Science, pp. 1951-1971. 11. Shell Global. FCC Unit Internals. [Online] 2023. [Cited: May 3, 2023.] https://www.shell.com/business-customers/catalysts-technologies/refinery-equipment/fcc-unit- internals.html. 12. Sadeghbeigi, Reza. Fluid Catalytic Cracking Handbook. s.l. : Butterworth-Heinemann, 2020. 13. Understanding unit pressure balance key to cost-effective FCC revamps. Dean, Christopher F., Golden, Scott W. and Hanson, Daryl W. s.l. : PennWell Corporation, 2004, Oil & Gas Journal. Development of a Generic OTS of an FCC Unit and Fractionator Column 49 14. Lieberman, Norman and Lieberman, Elizabeth. Working Guide to Process Equipment. s.l. : McGraw Hill Professional, 2008. 15. Aspentech. HYSYS Operations Guide. [Online] [Cited: February 10, 2023.] https://sites.ualberta.ca/CMENG/che312/F06ChE416/HysysDocs/AspenHYSYSOperationsGuide.pdf. 16. Taking advantage of the excess of thermal naphthas to enhance the quality of FCC unit products. Palos, Roberto, et al. s.l. : Elsevier, 2020, Journal of Analytical and Applied Pyrolysis. 17. Pragmatic Approach toward Catalytic CO Emission Mitigation in Fluid Catalytic Cracking (FCC) Units. Vjunov, Aleksei, et al. 11, 2021, Catalysts. 18. Iversen, Wes. Automation world. Operator Training Simulators to the Rescue. [Online] 2009. [Cited: May 11, 2023.] https://www.automationworld.com/products/control/article/13299078/operatortraining-simulators-to-the-rescue. Annexes 50 Annex A Annex A contains six videos that demonstrate the functionality of the OTS and the activation of the operating scenarios and malfunctions described throughout this thesis. A1. Overview of the OTS A1_Overview.mp4 A2. Scenario 2: CCR Increase A2_CCRIncrease.mp4 A3. Malfunction 1: Blocked Outlet A3_BlockedOutlet.mp4 A4. Malfunction 1: Blocked Outlet ESD A4_BlockedOutletESD.mp4 A5. Malfunction 2: Transmitter Failure A5_TransmitterFailure.mp4 A6. Malfunction 2: Transmitter Failure ESD A6_TransmitterFailureESD.mp4