scieee AI-readable full text Open interactive document viewer

Alkali-atom absorption spectroscopy and magnetometry using functionalized MEMs vapor cells

Rae, Rachel

Abstract

Optically pumped magnetometers (OPMs) have gained attention in recent years for their medical application in magnetoencephalography(MEG), a neuro-imaging technique that maps brain activity by measuring the magnetic fields produced by the brain's electrical currents. Addressing the current challenges of OPMs, including their size and cost, is imperative to making them a scalable solution for MEG. The focus of this project lies in enhancing the micro-fabricated micro-electromechanical systems (MEMs) vapor cells integral to OPMs by the incorporation of thin-film platinum resistive heaters. The functionality of these integrated heaters was qualified through spectroscopy and zero field resonance measurements. The calibration process yielded successful results that were compared against values given by the vapor's absorption spectrum. Additionally, effective packaging for magnetometry was achieved, evident in the zero field resonance spectrum, where compensation fields were identified and visualized through a heat map.

Full text

MSc in Photonics PHOTONICSBCN Universitat Politècnica de Catalunya (UPC) Universitat Autònoma de Barcelona (UAB) Universitat de Barcelona (UB) Institut de Ciències Fotòniques (ICFO) http://www.photonicsbcn.eu Master in Photonics MASTER THESIS WORK Alkali-atom absorption spectroscopy and magnetometry using functionalized MEMs vapor cells Rachel Rae Supervised by Dr./Prof. Morgan Mitchell, (ICFO) Co-supervised by Dr. Michael Tayler and Dr. Kostas Mouloudakis, (ICFO) Presented on 8th September 2023 Registered at Alkali-atom absorption spectroscopy and magnetometry using functionalized MEMs vapor cells Rachel Rae Atomic Quantum Optics Group, Institute of Photonic Sciences, 08860 Castelldefels (Barcelona), Spain Abstract. Optically pumped magnetometers (OPMs) have gained attention in recent years for their medical application in magnetoencephalography(MEG), a neuro-imaging technique that maps brain activity by measuring the magnetic fields p roduced by t he b rain’s e lectrical c urrents. A ddressing t he c urrent challenges of OPMs, including their size and cost, is imperative to making them a scalable solution for MEG. The focus of this project lies in enhancing the micro-fabricated micro-electromechanical systems (MEMs) vapor cells integral to OPMs by the incorporation of thin-film p latinum r esistive h eaters. T he f unctionality o f these integrated heaters was qualified through spectroscopy and zero field resonance me asurements. The calibration process yielded successful results that were compared against values given by the vapor’s absorption spectrum. Additionally, effective packaging for magnetometry was achieved, evident in the zero field resonance spectrum, where compensation fields were identified and visualized through a heat map. Keywords: Optically pumped magnetometry, Absorption spectroscopy, Sensors, Atomic physics, Zero-field resonance, MEMs 1. Introduction There is currently incentive from a range of fields to develop chip scale atomic sensing technologies from known wafer-level fabrication techniques that enable low cost mass production of the resulting devices.1,2The first micro-fabricated alkali vapor cells were demonstrated in 2003 and now lie at the heart of many such technologies, including atomic clocks, magnetometers, and gyroscopes.3The applications of these cells also extend to a variety of photonic devices, from magnetic field imaging in un-shielded environments to tunable wavelength references in cold atom sensors.4,5 The use of microfabricated vapor cells as optically pumped magnetometers (OPMs) specifically will be the focus of this thesis due to their relevant medical application in magnetoencephalography(MEG).6 Conventional MEG uses superconducting quantum interference devices (SQUIDs) which are based on superconducting Josephson junctions and can reach magnetic sensitivities of 10 aT/√Hz at low frequencies. However, SQUIDs operate at cryogenic temperatures which require large insulation from the source and a bulky set up, which limit the signal to noise ratio and spatial resolution of the measurements. OPMs by contrast, do not share these requirements and can be placed in closer proximity to the biomagnetic source. They may be integrated in arrays, typically of 50-100 sensors,7on wearable devices which allow for the subject to move and perform tasks while their brain activity is being recorded. Without the need for cryogenics, OPM MEG helmets can be made to fit any size of head, which has particular applications in the neuro-imaging of infants and children. However, going forward, improvements to OPM sensors are still required to increase their signal to noise ratio and in minimizing the cross talk between individual sensors in an array.8 The miniaturization and qualification of OPM devices for reliable and inexpensive mass production is therefore of great interest.9This requires that all Alkali-atom absorption spectroscopy and magnetometry using functionalized MEMs vapor cells 2 the components of the sensor can be scaled reliably to allow for wafer-level assembly of the structures. For example, the laser light required for optically pumping the atomic states of the magnetometer will be delivered by micro-fabricated vertical cavity surface emitting lasers (VCSELs). These VCSELs are grown epitaxially via a known process, allowing for custom design specifications and a wafer-level production scale. These lasers are stable and produce approximately 1 mW of optical power which is sufficiently high to operate a zero-field-resonance OPM.10,11 A further example would be biplanar coils that can be used to cancel out ambient magnetic fields and allow for zero field operation. These were designed so that they may be fabricated using standard printed circuit board(PCB) techniques.12 In addition to these secondary components of the OPM device, the micro fabrication of the alkali vapor cell in which magnetometry takes place, is a complex matter. Since the 1950s, evacuated glass cells containing alkali atoms have been fabricated for use in a variety of studies as they produce large spectroscopic signals and provide simple, well-defined quantum systems for study. This is because the atomic structure of atoms in the vapor phase is minimally affected by inter-atom interactions and wall collisions, providing a structure that is largely unperturbed especially in contrast to the frequency bands of solids.13 Already, there exist established alkali vapor cell fabrication techniques for optically pumped rubidium frequency references (i.e. atomic clocks), as they have applications in navigation systems, digital communications, and the synchronization of networks, with several thousand cells being manufactured each year to meet these demands.14 However, there are many requirements of an OPM vapor cell that are unique from those of an atomic clock vapor cell. For instance, an OPM vapor cell must be designed to be heated, as this produces a high vapor density and increases the sensitivity of the device to magnetic fields. Simultaneously, efforts must be made to maintain overall low thermal noise so as to avoid producing stray magnetic fields. A high pressure buffer gas inside the cell will also be important as it is used to decrease the collisions of the alkali atoms with the cell walls, which depolarizes the atoms.15,16 Previous work by the group has developed a dualcavity vapor cell through Si MEMs technology.12 The objective of the present work is to enhance this vapor cell by integrating heaters and thermocouples for added functionality. These allow for more efficient and controlled heating of the vapor. Integrated heaters are also much simpler to thermally insulate than external heaters. In this paper we discuss the qualification of these integrated heaters through tests of the cell’s absorption spectrum and its zero field resonance. 2. Theory 2.1. Alkali Atom Energy Level Structure Alkali-metal atoms are chosen because they have a single unpaired electron in their outermost shell, allowing the atomic energy to be sufficiently approximated by considering only the valence electron and nucleus. The electron’s intrinsic angular momentum, or spin (S), has values 1/2 and -1/2. The energy states an electron may occupy are characterized by orbital shells with their own angular momentum L, where the ground state has L=0, the first excited state has L=1, etc. Each state’s total angular momentum is J=L+S, leading to the splitting of the first excited state into J=1/2 and J=3/2 levels. The ground state meanwhile does not split. This results in two transitions from the ground state to the excited states J=1/2 and J=3/2 known as the D1 and D2 transitions. This splitting of energy states is known as the fine atomic structure. Considering electron-nucleus spin interactions introduces the total atomic spin F=I+J where I is the intrinsic angular momentum of the nucleus. From this, the energy states are split further into the hyperfine structure, depicted in Figure 1a. When the atoms are placed in a magnetic field, the hyperfine levels split even further, into Zeeman sublevels. These sublevels are simply a projection of the total atomic spin along a quantization axis mF=−F, −F+ 1,...F −1, F, with mFbeing a dimensionless quantum number whose allowed values are integer steps between -F and F. For a 87Rb alkali atom with a nuclear spin of I=3/2, the ground state Zeeman sublevels are depicted in Figure 1b. In the presence of a magnetic field, the angular momentum of the atom precesses between these sublevels, a process known as the Larmor precession, with a frequency of ωL= ∆EL/ℏproportional to the strength of the magnetic field.17 2.2. Absorption Spectrum The D1 atomic transition line (see Figure 1a) of rubidium 87 is known to be 377.107 463 5(4) THz (approx 795 nm18). Absorption occurs when an electron transitions from ground state to excited state through the absorption of a photon with an energy that matches the energy difference between the states. In other words the frequency of the photon must match the frequency of the energy transition based on Planks equation E=hν where his Plank’s constant and ν is the frequency. Alkali-atom absorption spectroscopy and magnetometry using functionalized MEMs vapor cells 3 (a) (b) Figure 1: (a) Energy levels considering the intrinsic spins and orbital angular momentum of an alkali atom; (b) Ground state Zeeman splitting for the case I=3/2. Taken from:.17 An absorption spectrum may be obtained by measuring the intensity of light in a range of frequencies after it has passed through an atomic sample. The absorbed frequencies will be less present in the transmitted light in a pattern characteristic to the elements in the sample. The intensity of absorption will depend on the amount of absorbing atoms in the sample. An analysis of the absorption spectrum may therefore be used to determine the number density of atoms in a sample, a relationship19 described by: I(ν) = I0exp −nrecfosclΓ (ν−ν0)2+ Γ2(1) where Iis the intensity of light at the output of the cell, ν0is the resonant frequency of the D1 line, Γ is the linewidth (HWHM) of the absorption, re≈2.8×10−15 m is the classical electron radius, c≈3.0×108m/s is the speed of light in a vacuum, fosc = 0.332 is the oscillator strength of the D1 line, nis the alkali number density, l= 1.5 mm is the path length of light through the cell, and I0is the intensity of light incident on the cell. Here we note that this relationship is only true for linearly polarized light. The linewidth of the absorption spectrum is influenced by a few different factors. To begin, there is a natural linewidth due the uncertainty principle limiting how precisely it is possible to define the energy of a state; ∆E∆t≥ℏand consequently ∆ν= 1/2π∆t. For the D1 transition line of alkali atoms this is about 4-6 MHz. In addition, buffer gas collisions which perturb the atoms will shift and broaden the spectral linewidth typically on the order of 1-100 GHz. This process is known as pressure broadening and is proportional to the number density of N2buffer gas. To recall, buffer gas is necessarily included inside of the cell to suppress wall collision relaxation. Finally, Doppler broadening occurs whenever the velocity of the atoms have some component νzalong the same axis as the propagation of light though the cell, causing the atoms to experience photon frequencies that are shifted according to the Doppler effect. This results in some amount of atoms absorbing off-resonant light and broadening the absorption spectrum on the scale of approximately 550-650 MHz for 87Rb at 100- 200°C.17 It is therefore apparent that the dominant broadening factor of the absorption spectrum is the pressure broadening. Figure 2: Absorption spectrum of ramping a 795 nm laser around the D1 transition line of 87Rb through a reference cell of 72%85Rb and 28%87Rb in order to calibrate the frequency axis of the oscilloscope data A typical absorption spectrum may be seen in Figure 2. This is a sample spectrum taken in our lab using polarized laser light, generated by a DBR source, attenuated to the scale of 10µW, and scanned through a range of wavelengths centered on 795nm through a reference cell of 72% 85Rb and 28 %87Rb. Notably, the absorption lines are in pairs which clearly shows the hyperfine splitting of the energy states. The inner two absorption lines are that of 85Rb because the distance between the lines corresponds to the characteristic ground hyperfine splitting of Alkali-atom absorption spectroscopy and magnetometry using functionalized MEMs vapor cells 4 ≈3GHz of 85Rb and because the absorption of 85Rb is higher, given its natural abundance and the similar absorption cross-section of the two species. For 87Rb, the outer lines, the 52S1/2ground state is split into F=1 and F=2 states, with a difference of 6.9GHz between them. The excited state, 52P1/2, experiences hyperfine splitting as well, however it is on the order of MHz, which means it is not visible on the scale of this graph, and is also smaller than the overall absorption linewidth due to the broadening effects previously mentioned. 2.3. Magnetometry Zero-field-resonance magnetometry is based on the fact that the measurement of the spin dynamics of atoms is sensitive to external magnetic perturbations. There are three competing physical mechanisms that are involved. These are a combination of electron excitation by light, collisional mixing and relaxation of electronic angular momentum, and electron spin precession. Optical excitation works by exposing the alkali vapor to a pump beam with a frequency that is resonant to the D1 transition and is circularly polarized. Being circularly polarized means that all of the beam’s photons have the same spin projection: along the direction of its propagation. When an atom absorbs a photon’s energy, the photon’s angular momentum must be considered, as the transition must satisfy the law of conservation of angular momentum. In this way, an atom will be both excited to the 52P1/2 state as well as to another Zeeman sublevel, either by +mFor −mF, depending on the handedness of the polarization of the photon. As the pump beam photons are uniformly polarized, the atoms will be excited in a uniform direction along the quantization axis. The excited states may decay randomly in any of the +mF,0,−mFdirections, however because of the highly directional absorption process, all the atoms will ultimately settle in the furthest Zeeman sub level within the ground state, making the vapor highly polarized and essentially transparent to any further photon absorption. The state of the vapor’s polarization may be better described as the magnetization Mof the vapor. Mis thus directly proportional to the transmission signal S of the pump beam through the vapor. One very important phenomenon is that any external magnetic field in the transverse direction to the optical pump beam will produce a torque on the net Mof the vapor, resulting in what’s known as Larmor precession around the magnetic field axis with a frequency proportional to the strength of the magnetic field.20 This Larmor precession is described in the final term of Equation 2 where the atomic gyromagnetic ratio is γwith a value of 7Hz/nT,21 and where H is the transverse magnetic field. This precession mechanism periodically realigns the angular momentum of the vapor to a state that may absorb more of the resonant light’s photons, which makes the vapor highly sensitive to the magnitude of an ambient magnetic field as it is responsible for the frequency of this precession. This will be the basis for sensing the magnetic fields. Larmor precession falls out of phase due to interatom collisions which scramble the orientation of the atomic spins and weaken the overall M. One way around this is to operate in the spin-exchange- relaxation-free SERF regime where the atoms exchange spin so quickly compared to the precession frequency that the average spin is what interacts with the field, and is not destroyed by decoherence. To maximize this effect, heating the vapor to increase the alkali atom number density is recommended. Another way to maximize this effect is to operate in a very low transverse ambient magnetic field in order to reduce the precession frequency. The balance of relaxation, decoherence, and optical excitation results in a ”steady state solution” and operating in the SERF regime allows for a steady state with a strong Mto be maintained. The steady state solution can be found by setting dM/dt equal to zero in Equation 2, which describes the evolution of the Mof the vapor. The first term describes the optical pumping of the vapor where M0 is the maximum achievable magnetization given that there is only optical pumping in the system, and Tpis the pumping time required to reach said maximum. The second term describes the relaxation rate of all processes, where T2is known as the transverse spin relaxation time. As previously mentioned, the final term describes the effect of a transverse magnetic field Hon the system.22 d dtM=1 Tp (M0−M)−1 T2 M+γM×H(2) Any transverse ambient field will be represented by ω0=γH0and can be solved for by modulating the field with a second magnetic field H1cos ωt along the same transverse axis. Here it is important to apply a modulation with ω≪1 Tp+1 T2so that the oscillations of the applied field are faster than the relaxation time and the Mof vapor cannot follow the modulating field. Using ω0+ω1cos ωt and 1/τ1= 1/Tp+ 1/T2to solve Equation 2, the following solutions are found:23 M(s) x=M′ 0J0(γH1 ω)Jp(γH1 ω)ω0τ1 1+(ω0τ1)2sin pωt (3) M(s) x=M′ 0J0(γH1 ω)Jp(γH1 ω)1 1+(ω0τ1)2cos pωt (4) Alkali-atom absorption spectroscopy and magnetometry using functionalized MEMs vapor cells 5 The solutions here are represented by Bessel functions Jnand Jpon parametric resonance (n=0). Equation 3 shows the out of phase components (p=even) resulting in a dispersion shape and Equation 4 shows the in phase components (p=odd) resulting in an absorption shape. Both periodic solutions are centered on the value of ω0allowing for a very sensitive determination of ω0. These results have been achieved mathematically, but also represent the physical results of demodulating the resulting periodic signal S through the vapor cell by use of a lock-in amplifier. Figure 3: Exploded view of the vapor cell holder showing the placement of the solder pads in the corners where the three layers will be soldered together in a sandwich configuration 3. Results 3.1. Design The atomic vapor cells are based on a design described previously by the group.12 The etched high-Z silicon body comprises two chambers connected by microchannels, and is sandwiched in between two glass windows as indicated in Figure 3. The internal dimensions of each chamber are 4 mm wide, 4 mm long, and 1.5 mm high. One of the chambers is designated as the ‘reservoir’, where before sealing shut it is loaded with 87Rb azide; the azide subsequently decomposes into Rb metal and N2buffer gas after sealing and activation.24 The other chamber is the ‘sensing’ chamber, into which vapor-phase atoms diffuse when the cell is heated. In the current project, a platinum coating layer is applied to each of the glass windows. The pattern of this layer is made up of traces that will be used as ohmic heaters or temperature sensors. Traces are laid out with outward and return current paths close to one another so that stray magnetic fields are minimized, and in such a way as not to block the laser light used to probe the sensing chamber. The traces terminate with a set of breakout pads at the edge of the cell window, on the side furthest away from the sensing chamber, which will be wirebonded to external circuitry. A 3-layer PCB sandwich holder was engineered to hold the cell firmly and connect it to the rest of the electronics, as illustrated in Figure 3. The PCB boards are made out of standard FR4 fiberglass substrate, which has a low thermal conductivity. Even so, the design was made to keep the area of contact with the cell as low as possible to avoid conductive losses. The thickness of the top and bottom PCB boards were designed to be higher than the maximum wirebond loop height in order to protect the wirebonds from being compressed, and the tight fit to the cell ensured minimal relative movement between the contacts on the cell and the PCB holder. Protecting these bonds from movement is an important design feature, as the modules should be capable of withstanding normal handling without causing the electrical connections to lose integrtiy. This sandwich holder was then wrapped with a layer of 1-mm-thick, flexible aerogel material for further insulation (Airloy®HT flexible sheet). 3.2. Packaging To mount the vapor cell in the PCB structure, cells were first checked under a microscope for scratches that would indicate broken traces, and residues such as grease, to ensure clear transmission into the cell. Tweezers were used to place the chosen cell into the central PCB, and the top and bottom PCBs were then soldered together at the contacts shown in Figure 3, securing the cell tightly. The solder joint placement was intentionally distant from the cell to mitigate the influence of magnetic impurities from the solder material on the atomic dynamics. Next, the contacts on the middle PCB (standard 1µm-thick electroless nickel-immersion gold- (ENIG) plated copper) and the platinum breakout pads on the cell were connected by means of room temperature aluminum wedge-wedge wire bonding. The wirebonder used was the West-Bond model 7476e-79. The first bond was made onto the PCB contact with 0.4 W ultrasonic power, 40 ms bond time, and 21 g of force. The second bond was then made to the platinum pad contact with 0.4 W ultrasonic power, 40ms bonding time, and 25 g of force. Finally Aerogel insulation was placed around the PCB holder, with holes cut exactly at the sensing chamber windows to allow optical access. Alkali-atom absorption spectroscopy and magnetometry using functionalized MEMs vapor cells 6 3.3. Calibrations A calibration of the resistance-temperature relationship of the platinum traces was conducted to ensure accurate and self-reliant temperature determination within this cell batch and to account for potential variations in platinum coating between fabrication runs. Figure 5: Raw data from the calibration of the thin film platinum traces temperature coefficient through the use of a mineral oil bath slowly heated. The thermistor data from both the sensing and reservoir chambers is included. The design of the traces on both the top and bottom glass is as follows: each have a coiled thermistor trace over the reservoir chamber, a coiled thermistor trace over the sensing chamber, and two coiled heaters over the sensing chamber. The thermistor traces provide resistance values that may be used to calculate the temperature on the window of each chamber, which closely approximates the temperature inside each chamber. The heating traces will have a voltage potential applied across their lengths to create a current and as a consequence Ohmic heating. The following experiment used the thermistor traces to qualify the resistive properties of all the traces. There exists a simple linear relationship between the resistance of the platinum traces and their temperature: R(T) = ρ t L W(1 + α∆T) (5) where ρP t is the resistivity of thin film platinum which is known to be 2 ×10−7Ωm, tis the thickness of the trace which is typically 100-500 nm, L is the length of the trace which is on a scale of 1-5cm, W is the width of the trace which is about 20 µm, and αP t is the temperature coefficient of thin film platinum which in theory is 2000 ppm/K. The experimental value of αP t was measured by a immersing the cell- PCB structure in a mineral oil bath of known temperature and connecting the thermistor traces each to a digital multimeter. The bath was heated and a submerged thermocouple was used to record the temperature while the multimeters tracked the change in resistance, the results of which have been plotted in Figure 5. The data of each thermistor was then plotted separately and a linear fit was made for each. Their average was taken, and the experimental value of the temperature coefficient of thin film platinum was determined to be: 2720 ±30 ppm/K. This value was used to determine the temperature of the chambers for the rest of this project. An initial test of the cell heaters was then performed by running the heater traces at approximately 200°C for twelve hours. During the first three hours, the rubidium droplets on the sensing chamber window fully evaporated. Despite diffusion through microchannels ensuring uniform number density between reservoir and sensing chambers, the reservoir chamber remained comparatively cooler due to its distance from the heaters and the subsequent heater shutdown induced differential condensation due to rapid cooling. This optimized the rubidium vapor density in the sensing chamber, facilitating the experiment’s objec- Figure 4: A series of time-lapse photos showing the state of the 87Rb droplets on the window of the sensing chamber of the vapor cell, recorded in lengths of time after the on-cell heaters were turned on to 200°C Alkali-atom absorption spectroscopy and magnetometry using functionalized MEMs vapor cells 7 tives without obstructing light transmission. A timelapse view of this experiment can be seen in Figure 4. 3.4. Experimental setup 3.4.1. Absorption measurements: The functionality of the integrated heaters was qualified in this section through an analysis of the absorption spectrum of 87Rb vapor inside the MEMs vapor cell. Notably, the relationship between the temperature Tof the vapor and its number density nwas determined experimentally and compared to the theoretical values. Figure 6: Experimental set up for 87Rb absorption spectroscopy of the MEMs vapor cell. Input light arrives from the fiber in the bottom left corner of the image and travels towards the beam splitter cube, splitting the light towards the two photo detectors, the signals of which were connected to the oscilloscope seen in the background. This figure does not include the reference cell used for calibration. The absorption spectrum was determined using a set up involving collimated laser light, generated by a DBR source and scanned through a range of frequencies, passed through a polarising beam splitter (PBS) and then coupled into a polarization maintaining FC/APC fiber. The output light from the fiber was then passed through a polarizer on a rotation mount so that polarisation fluctuations produced by the fiber would not be propagated as intensity fluctuations. This is according to Malus’ law I=I0cos2θ(t) where θ(t) describes the polarisation of light as a function of time. The polarisation of light was then rotated to 45°by use of a half wave plate and passed through a polarising beam splitter (PBS) cube, separating the beam into its horizontal and vertical components, propagating at 90°from each other, towards separate photo detectors. One beam was passed through a reference cell, while the other was passed through the MEMs vapor cell. Both beams were attenuated according to absorption signal saturation within the cells. This set up may be seen in Figure 6. The reference cell was used to calibrate the frequency axis of the oscilloscope data by centering the laser frequency ramp around the D1 transition. The absorption spectrum in this range can be seen expanded in Figure 2. A known distance of 6.9 GHz between the F=1 and F=2 states of 87Rb vapor was used to convert the arbitrary time units given by the oscilloscope into GHz. In addition, the central point of resonance, which represents a transition from the ground state without hyperfine splitting, was assigned as the zero detunning point of this scale, as it has a known distance of 2.6 GHz from the F=2 line and 4.3GHz from F=1 line. After this, the reference cell was removed so that the light incident on the vapor cell could be compared against its absorption signal. This allowed for any intensity fluctuations still present in the laser to be accounted for. Figure 7a) presents the absorption spectrum obtained from the MEMs vapor cell across different temperatures, achieved by supplying the heaters with different voltages, and recorded following temperature stabilization indicated by the thermistors. Iterative measurements were conducted from 20 to 30V by increments of 2V, the spectrums of 20, 22, 24, 26V are presented here. The corresponding vapor temperatures, derived from thermistor data, were calculated using the values from the previous calibration of the platinum traces. The oscilloscope data was subsequently downloaded and analyzed using Wolfram Mathmatica 13.2. The shape of the spectrum deviates from that seen in Figure 2 because in order to have a visible signal from the MEMs vapor cell, the temperature must be increased such that there is significant broadening and shifting due to the increased buffer gas pressure. A non linear fit was made to these spectrums using Equation 1 and from this, the number density n was determined. There is a known exponential relationship between the number density and the temperature for 87Rb: n(T) = 1 T10exp[21.866 + 4.312 −4040/T].17 The theoretical number densities were thus calculated for each temperature and compared against the number densities calculated from the non linear fit. The discrepancy between the two values was roughly calculated to be 0.17 ×1014 cm−3and is represented by the error bars seen in Figure 7b). Alkali-atom absorption spectroscopy and magnetometry using functionalized MEMs vapor cells 8 Figure 7: a) The absorption spectrums for four temperatures of increasing magnitude, normalized against the maximum intensity transmitted b) The relationship of number density to temperature follows an exponential function 3.4.2. Magnetometry: Switching from absorption to magnetometry measurements required further packaging of the MEMs vapor cells. The packaging process was repeated with new cells, and the PCB structure was fit into a 3D printed prototype module. This module is designed to eventually house all the components required for MEG OPMs. The trajectory of the laser light through the module was as follows: light incident into the module encountered a polarising mirror at an angle of 45°and was deflected downwards through a small (5 mm × 5 mm ×0.25 mm) quarter wave plate into the vapor cell. Underneath the cell was another mirror at 45° deflecting the light back outside of the module along its original path, as seen in Figure 8a. The quarter wave plate was a true zero order wave plate sourced from Precision Micro-Optics Inc. The handedness of the circularly polarized light produced by the quarter wave plate was tested by a polarimeter before it was integrated into the module. To measure very small ambient magnetic fields it is necessary to conduct the experiment inside a heavily shielded environment. The magnetic shield used in this experiment was made up of three outer layers of mu metal and one inner layer of ferrite. Precautions were taken to avoid magnetizing the shield, including the use of non-magnetic tools. The shield was designed to reduce external magnetic noise to 1 fT/√Hz. It is interesting to note here that human brain signals are on the scale of pT. Integrated inside the shield was a three axis magnetic field coil. Ultimately any stray magnetic fields that could be produced inside the shield will be compensated for by this coil. Even so, magnetic fields produced by the module should be avoided as much as possible. For this reason, connections to the heating/sensing elements were soldered to long cables that could be properly connected to the necessary voltage source and ohm meters outside of the shield. It was convenient to use an Ethernet cable to solder and combine all of the connections, and thread it through a hole at the top of the shield. Additionally, the alignment of the module inside the shield was tested at this point to attain optimal light transmission efficiency through the cell. This was done by comparing the intensity of the incident to output light from the module, with an achieved efficiency of roughly 60%. A measurement of the zero field resonance in this set up will reveal magnetic field values necessary to compensate for non zero magnetic fields around the vapor cell. Voltage was applied to the cell heaters to reach a temperature of approximately 180 °C to ensure ample number density to produce absorption effects. A magnetic field transverse to the light propagation was then ramped with a function generator while the magnetic fields on the other two axes were iterated in magnitude. The sharpness of the transmission signal was recorded for each iteration, where sharpness is a function of the intensity to linewidth ratio. A program was written in Matlab to automate this process, the results of which can be seen in Figure 8b. The highest transmission will occur at the zero field resonance because this is where the vapor exists in its most strongly polarized form (M0). Any transverse magnetic field would allow for spin precession and depolarization of the atoms, resulting in increased absorption and thus decreased transmission as compared to the maximum. The behaviour of the