scieee AI-readable full text Open interactive document viewer

Meteorological aspects of self-initiated upward lightning at the Säntis Tower (Switzerland)

Pineda, Nicolau,Figueras i Ventura, Jordi,Romero Durán, David,Mostajabi, A.,Azadifar, M.,Sunjerga, A.,Rachidi-Haeri, Farhad,Rubinstein, M.,Montañá Puig, Juan,Van der Velde, Oscar Arnoud,Altube Vázquez, Patricia,Besic, Nikola,Grazioli, Jacopo,Germann, Urs

Abstract

Interest in exploring the meteorological conditions favoring upward lightning from tall man-made structures has grown in recent years, largely due to the worldwide expansion of wind energy. To this end, instrumented towers existing around the world are the most suitable places to study upward lightning. In this context, an LMA network was deployed around the Säntis Mountain (northeast Switzerland) during the summer of 2017, in order to complement the long-term measurements currently held at the Säntis telecommunications tower, a lightning hot spot in central Europe. This campaign allowed, for the first time, to gather a comprehensive set of observations of self-initiated upward lightning emerging from the Tower. With the help of C-band dual-polarimetric radar data, the present work focuses on the meteorological conditions conductive to self-initiated upward lightning from the Säntis. The analysis revealed that the upward propagating positively charged leaders spread mostly horizontal above the melting level, after an initial short vertical path from the tower tip. After this initial stage, the majority of upward leaders were followed by a sequence of negative return strokes. The inception upward lightning under a stratiform cloud shield would be favored by the low height of the charge structure. From the obtained results, it turns out that a key feature favoring self-initiated upward lightning would be the proximity of the tower tip to the melting level.

Full text

1 Confidential manuscript to be submitted to the Journal of Geophysical Research – Atmospheres 1 Last update 20190402 2 METEOROLOGICAL ASPECTS OF SELF-INITIATED UPWARD LIGHTNING AT THE SÄNTIS TOWER 3 (SWITZERLAND) 4 Nicolau Pineda1,2, Jordi Figueras i Ventura3, David Romero2, Amirhossein Mostajabi4, 5 Mohammad Azadifar5, Antonio Sunjerga4, Farhad Rachidi4, Marcos Rubinstein5, Joan 6 Montanyà2, Oscar van der Velde2, Patricia Altube1, Nikola Besic36, Jacopo Grazioli3, Urs Germann3, 7 Earle R. Williams7 8 1. Remote Sensing Unit, Meteorological Service of Catalonia, Barcelona, Spain 9 2. Lightning Research Group, Technical University of Catalonia, Terrassa 08222, Spain 10 3. Radar, Satellite and Nowcasting Division, MeteoSwiss, Locarno-Monti, Switzerland 11 4. Electromagnetic Compatibility Laboratory, Swiss Federal Institute of Technology, Lausanne, Switzerland 12 5 Institute for Information and Communication Technologies, University of Applied Sciences of Western Switzerland, 13 Yverdon-les-Bains, Switzerland 14 6 Environmental Remote Sensing Laboratory, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland 15 7 Massachusetts Institute of Technology, Cambridge, Massachusetts, 02139 USA 16 17 ABSTRACT 18 Interest in exploring the meteorological conditions favoring upward lightning from tall man-made 19 structures has grown in recent years, largely due to the worldwide expansion of wind energy. To this 20 end, instrumented towers existing around the world are the most suitable places to study upward 21 lightning. In this context, an LMA network was deployed around the Säntis Mountain (northeast 22 Switzerland) during the summer of 2017, in order to complement the long-term measurements 23 currently held at the Säntis telecommunications tower, a lightning hotspot in Central Europe. This 24 campaign allowed, for the first time, to gather a comprehensive set of observations of self-initiated 25 upward lightning emerging from the Tower. With the help of C-band dual-polarimetric radar data, the 26 present work focuses on the meteorological conditions conductive to self-initiated upward lightning 27 from the Säntis. The analysis revealed that the upward-propagating positively-charged leaders spread 28 mostly horizontal above the melting level, after an initial short vertical path from the tower tip. After 29 this initial stage, upward leaders were followed by a sequence of negative return strokes. The inception 30 of those upward lightning, under a stratiform cloud shield, would be favored by a low height charge 31 structure, the main negative layer close to the tower tip. The overall electrical structure would consist of 32 a positive charge in the isothermal layer near the 0ºC, a main negative charge (~4km / -5°C) and a low- 33 density positive above (between -10ºC and -20ºC). 34 KEY WORDS 35 Self-initiated upward lightning, Upward-propagating Positively-charged Leaders Lightning Mapping 36 Array, Polarimetric radar, Hydrometeor Classification Product 37 2 38 1. Introduction 39 Understanding the mechanisms of upward lightning (UL) is an important topic in lightning research. 40 The interest in lightning emerging from tall structures has grown in recent years, in particular due to 41 the rapid expansion of wind energy globally [e.g. Rachidi et al., 2008; Foley et al., 2012]. Recent studies 42 have dealt with this topic, relying on comprehensive observations from high-speed video [e.g. Flache et 43 al., 2008; Qie et al., 2011; Miki et al., 2012; Warner, 2012; Montanyà et al., 2012; Saraiva et al., 2014; Lu 44 et al., 2012; Jiang et al., 2014] to current measurements on instrumented towers [e.g. Diendorfer et al., 45 2009; Romero et al., 2012, 2013; Montanyà et al., 2014]. These studies have revealed that human-built 46 structures above a certain height are prone to initiate UL, as the tops of these tall towers emerge above 47 the ground corona layer and are exposed to high ambient E-fields [Mazur, 2016]. 48 However, an appreciable number of such UL may go unnoticed by conventional Lightning Location 49 Systems (LLS), as they may contain only an initial continuous current (ICC), with neither 50 superimposed pulses nor return strokes [Berger, 1967; Diendorfer et al., 2009; Smorgonskiy et al., 2013; 51 Azadifar et al. 2016a]. In this regard, 3D mapping systems like the Lightning Mapping Array (LMA) 52 offer a unique opportunity to investigate upward leaders emerging from tower tips. Contrary to high- 53 speed video, which may suffer from cloud screening effects, the LMA depicts lightning channels within 54 the cloud with sufficient time resolution and spatial precision to locate their origin and propagation 55 path. Relying on LMA data, Edens et al. [2012] and Hill et al. [2013], have analyzed upward-propagating 56 leaders (UPL) on rocket-and-wire triggered lightning; Wang et al., [2018] and Schultz et al. [2018] have 57 examined winter UL in Japan and the U.S., respectively; and Montanyà et al. [2014] and Pineda et al. 58 [2018] have studied ULs emerging from wind turbines. These works have revealed that UL are linked 59 to particular meteorological regimes. 60 However, limited studies exist on the meteorological aspects favoring the inception of UL. Some focus 61 on the windy conditions that may assist the initiation of upward leaders; since winds above a certain 62 speed would reduce the amount of space charge accumulated in the vicinity of the tip of an object 63 [Wang and Takagi, 2012; Becerra, 2014; Wu et al., 2017]. Zhou et al. [2014] pointed out that lower 64 ambient temperature may also have an effect on the initiation of upward leaders: keeping in mind the 65 dependence of the electrification processes on temperature [e.g. Takahashi, 1978; Saunders et al., 2006], 66 cloud charges are at lower altitudes in winter, favoring interaction with ground structures such as 67 towers and wind turbines, as reported in the literature [Wang and Takagi, 2012; Schultz et al., 2018; 68 Pineda et al., 2018]. Lately, studies such as Warner et al. [2014], Jiang et al. [2014], Wang et al. [2017], 69 Pineda et al. [2018] have incorporated weather radar data into the analysis, providing a comprehensive 70 survey on the thunderstorm characteristics related to UL. 71 To shed new light on the meteorological aspects favoring the inception of upward lightning, an LMA 72 measurement campaign was carried out during the summer of 2017 in the surroundings of the Säntis 73 Mountain (2,505 m ASL, Switzerland), aiming to measure lightning activity at the Säntis tower (Fig.1). 74 The campaign was a joint venture between the Electromagnetic Compatibility Laboratory (EMC-Lab) of 75 the Swiss Federal Institute of Technology (EPFL), the University of Applied Sciences of Western 76 Switzerland (HEIG-VD), and the Lightning Research Group (LRG) of the Technical University of 77 Catalonia (UPC). The LMA was deployed at the end of June and was operative since mid-August. During 78 that period, direct strikes to the Tower were registered on ten days by in-situ by EMC-Lab sensors. For 79 3 the present analysis we have focused on three of them (June 29, July 10 and 14), days in which all six 80 LMA stations were fully operative and processed data depicted upward leaders emerging from the 81 Tower. 82 83 In particular, the present study is concerned with the cloud microphysics, electrification and charge 84 structure favoring the inception of self-initiated upward lightning (SIUL) from the Säntis Tower. In this 85 regard, the incorporation of high-resolution MeteoSwiss polarimetric radar data in the analysis 86 provided a wealth of information concerning the thundercloud microphysical properties. 87 88 89 Figure 1. Säntis Tower [47°14′57′′N and 9°20′32′′E) at the Säntis Mountain (2,505 m ASL), Northeastern Switzerland. 90 Source: Federal Office of Topography (Swisstopo) and picture by maxpixel.net 91 92 2. Data and Methodology 93 During the summer of 2017, a Lightning Mapping Array system (LMA) was deployed around the Säntis 94 Mountain aiming to measure lightning activity at the Säntis Tower (124-m tall, 47°14′57′′N, 95 9°20′32′′E), see Fig.1. The primary goal for data collection was to capture UL emerging from the Säntis 96 Tower to complement the channel-base current waveforms that are currently measured at the Tower. 97 98 2.1. Lightning Data 99 2.1.1. Lightning current measurements at Säntis 100 The Säntis Tower has been instrumented by the EPFL and HEIG-VD teams to measure lightning current 101 and its time derivative waveforms [Romero et al., 2012, 2013; Azadifar et al., 2014]. Indeed, Säntis is a 102 lightning “hotspot” in the eastern Swiss Alps, it has the highest lightning flash density in Switzerland, 103 with about 100 flashes per year; and a relatively high value of flash multiplicity [Manoochehrnia et al., 104 4 2008]. According to Azadifar et al. [2016a] lightning at the Säntis Tower is essentially of the upward 105 type. 106 2.1.2. Lightning Mapping Array 107 The LMA system locates radio emissions in the very high frequency range (VHF, 60–66 MHz) in three 108 dimensions by a time-of-arrival analysis of pulses using at least five stations. Each station samples the 109 maximum signal amplitude and its GPS-derived precise time over 80 μs intervals. Typically, 2000 to 110 3000 sources per second are located during lightning flashes. The background noise level at the sites 111 varies usually between -80 dBm and -60 dBm. Power in dBW is available for every located source (see 112 Rison et al. [1999], Thomas et al. [2001] and Thomas et al. [2004] for more details on LMA systems). 113 The deployment of an LMA in the Säntis mountainous area was challenging, since the VHF detectors 114 require a line of sight to the Tower. The site selection was made taking into consideration practical 115 installation aspects such as accessibility and reliable access to AC power and communication; 116 constraints that greatly limited the number of desirable sites. Moreover, to accurately locate the three- 117 dimensional position of a lightning source, the LMA stations must be sufficiently separated from each 118 other so that the signal from a source arrives at each station at significantly different times [Thomas et 119 al., 2004]. Finally, the sensors were located in relative quiet radio frequency (RF) Swisscom and 120 Swisscom Broadcast stations around the Säntis. The sensor baseline ranged from 2 to 11 km. Due to 121 the roughness of the terrain, the coverage of the LMA was uneven. Data processing has shown that 122 roughly an area of 45 by 60 km was reliably covered by the network, even though the usual range of 123 the LMA detection system is between 100-200 km [Koshak et al., 2004; Fuchs et al., 2016]. A minimum 124 of five LMA stations were required to process the VHF sources, and a maximum chi-square threshold of 125 1.0 was set to validate source locations Afterwards, VHF source points were grouped into flashes using 126 the space and time criteria of Thomas et al. [2004]. 127 2.1.3. EUCLID lightning data 128 During the campaign, the European Cooperation for Lightning Detection Network (EUCLID) provided 129 complementary lightning data in the vicinity of the Säntis Tower. EUCLID is a consortium of 19 130 European national lightning detection networks with the aim of identifying and detecting lightning all 131 over the European area (http://www.euclid.org). Details on the EUCLID system can be found in Schulz 132 et al. [2016] and Poelman et al. [2016]. EUCLID works in a frequency range different from that of the 133 LMA and does not observe the same processes of a lightning flash. While LMA depicts the channeling 134 process inside the cloud, EUCLID mainly provides the location of cloud-to-ground (CG) return strokes. 135 2.2. Leader Speed and Charge Structure Determination 136 The LMA system mainly locates sources from negative leaders propagating through positively charged 137 regions [e.g., van der Velde and Montanyà, 2013]. Weaker sources from recoil leaders [e.g., Mazur, 2002; 138 Williams and Heckman, 2012] are detected as well, allowing the mapping of positive leaders [Shao et al., 139 1999; Edens et al., 2012]. Interestingly, negative and positive leaders propagate at characteristic 140 horizontal speeds (105 and 2 104ms-1 respectively); The propagation speed of the positive channels 141 being almost an order of magnitude lower [e.g. Mazur et al., 1998; Shao and Krehbiel, 1996]. Taking 142 advantage of those characteristic speeds, van der Velde and Montanyà [2013] developed a method that 143 allows to determine the leader speed and, therefore, to infer the leader polarity. The time-distance- 144 altitude projection displays LMA sources by horizontal distance relative to a fixed reference point of 145 5 choice, usually the flash initiation. This way, by simplifying x-y into one horizontal dimension, a time 146 axis allows a qualitative analysis of leader speed and their continuity in time and space. Reference lines 147 (2× 104, 1×105, and 1×106ms-1) for slopes of LMA sources offer guidance for the leader speed 148 determination. Besides, horizontal leader propagation heights derived from the LMA can help to infer 149 the sign of the charge region in which the leader is propagating, assuming that a lightning leader moves 150 through charge of opposite polarity, thereby serving to neutralize space charge [Coleman et al., 2003; 151 Rust et al., 2005; Wiens et al., 2005, Williams and Heckman, 2012; Montanyà et al., 2014]. 152 2.3. Weather Radar Imagery 153 Polarimetric weather radar data were available from the MeteoSwiss C-band radar network [Germann et 154 al., 2015]. In particular, we made use of the Albis radar (928 m ASL, 47.285°N 8.513°E), located near the 155 city of Zurich, 60 km East from the Säntis area. The radar imagery has been used for storm morphology 156 analysis and to estimate the horizontal dimensions of the storm system, by using the classifications by 157 Parker and Johnson [2000] and Duda and Gallus [2010]. Besides, the hydrometeor classification product 158 generated by MeteoSwiss [Besic et al., 2016] has been analyzed for the SIUL events. The hydrometeor 159 product can help diagnose hail cores, snow-to-rain transitions, and regions of graupel and ice particles 160 [e.g. Dolan and Rutledge, 2009]. Indeed, one of the important uses of the polarimetric weather radar data 161 is the detection of the melting layer in stratiform precipitation, based on the conventional “bright band” 162 signature [Kumjian, 2013]. The bright band (BB) is a thin, rather horizontal layer of enhanced radar 163 reflectivity resulting primarily from the fast increase in the dielectric constant of particles during the 164 melting process [e.g. Austin and Bemis, 1950; White et al., 2002]. The layer over which the 165 transformation from ice to water occurs defines the melting layer. The top of the melting layer is the 166 melting level, also commonly accepted as the altitude of the 0ºC constant-temperature surface. 167 168 2.4. Ancillary data 169 Vertical temperature profiles for the Säntis area were obtained by means of model-output soundings 170 from MeteoSwiss. Key environmental temperatures (0°C, -10°, -20°C and -40°C) related to the 171 convective microphysical and electrification processes [e.g. Krehbiel, 1986; Brook et al., 1982; 172 MacGorman and Rust, 1998] were selected from these profiles. 173 Besides, visible and infrared imagery from the Meteosat satellite were used to monitor cloud systems 174 that affected the area of study. Cloud top temperatures from the infrared channel were used for cloud 175 system characterization [Maddox, 1980; Maddox et al., 1983]. The morphological scheme proposed by 176 Jirak et al. [2003] was used to characterize Mesoscale Convective Systems (MCS). 177 178 Finally, wind direction and speed data, measured by a Meteoswiss weather station, was gathered for 179 the analyzed episodes. The Säntis meteorological station is located on top of the Säntis Mountain near 180 the instrumented tower. 181 182 2.5. Self-initiated vs. lightning triggered upward lightning 183 ULs can be classified into two basic types [e.g. Wang and Takagi, 2012], either self-initiated (SIUL) due 184 to locally strong electric fields; or lightning-triggered (LTUL) when induced by prior lightning discharges 185 in the vicinity, which provide the necessary electric fields for the inception and stable propagation of an 186 upward leader. The proportion of SIUL and LTUL reported in the literature shows substantial 187 differences from tower to tower [see Smorgonskiy et al., 2015 and references therein]. Smorgonskiy et 188 6 al. [2015] pointed out that the underlying causes of such differences are diverse whether physical 189 (tower effective height, topographical conditions, other tall structures in the vicinity) or methodological 190 (e.g. time window and distance to the tower to determine prior CG lightning in the vicinity). In this 191 regard, intra-cloud channels propagating overhead may also induce LTUL, and its consideration (or not) 192 in the method to report prior lightning activity in the vicinity of the tower may have a great influence 193 on the SIUL/LTUL proportion obtained. In the present study, UL from the Säntis were classified as LTUL 194 or SIUL depending on whether or not lightning activity (either from LMA or EUCLID) had been 195 reported within a distance of 30 km around the tower and within a 5-s time window before the start of 196 the flash. 197 198 3. Results 199 3.1. Self-initiated upward lightning from Säntis 200 A clear depiction of SIUL at the Säntis Tower was obtained through the combination of LMA, current 201 waveforms measured at the Tower and lightning detections by EUCLID. Figure 2 shows an example. 202 The initial continuous current (ICC) measured at the Tower, associated with the upward-propagating 203 positively-charged leader (+UPL) phase, lasted for about 400 ms and effectively transported negative 204 charge to ground. The UPL, together with the ICC, comprise the initial stage (IS) of the UL. After the IS, 205 a sequence of twelve dart-leader-return-stroke sequences carried additional negative charge to ground 206 (Figure 2a), similar to those in downward negative lightning discharges [Rakov and Uman, 2003]. Eight 207 of these strokes at the Tower were detected by EUCLID. Focusing on the ICC phase, Figure 2b shows the 208 LMA VHF sources associated with the development of the +UPL, some of them concurrent with the 209 impulsive current pulses occurring in this stage of discharge. 210 Nineteen self-initiated upward leaders emerging from the Säntis Tower, like the one presented in 211 Figure 2, were recorded on tree different days during the campaign. A summary is given on Table 1. The 212 majority of these UPL were mapped by the LMA with sufficient resolution of leader channels to clearly 213 identify characteristics such as the channel origin, maximum altitude and polarity. Detailed analysis of 214 the current measurements at the Tower related to these events will be the subject of a future paper. 215 216 Multiple current pulses and corresponding EUCLID-detected strokes (either IC or CG) were measured 217 in sixteen of the nineteen events. As many as 51 pulses and 47 strokes were associated with a single 218 LMA flash (event #8). Statistical distributions from Romero et al. [2013] show that the flash multiplicity 219 at Säntis has a lognormal distribution with a median of 8 pulses per flash, with a maximum of 69. The 220 UL analyzed in the present study had a larger mean multiplicity, with 19. Schultz et al. (2018] also 221 reported multiple CG flashes associated with LMA observations of UL during electrified snowfall events 222 (data from the U.S. National Detection Lightning Network, NDLN). 223 224 Almost all EUCLID strokes at Säntis associated with SIUL were of negative polarity, only event #18 225 presented a 4.5 kA positive stroke after the first negative (bipolar flash). The largest magnitude negative 226 CG stroke showed a peak current of -55.6 kA (event #15), and the population's average and median 227 peak currents were -16.7 kA and -15.8 kA, respectively (for those classified as CG by EUCLID). Romero 228 et al [2013] reported a peak current average of -6.4 kA. 229 230 7 a) b) Figure 2. Waveform associated with a self-initiated upward lightning (positive leader) occurred on June 29 at 14:06:12 UT . 231 (a) Original current waveform. Concurrent EUCLID strokes are presented in this same plot with crosses. Time is 232 relative to the beginning of the measurement of the ICC at the Tower. (b) Expanded view of the initial continuous 233 current associated with the upward positive leader phase, together with the LMA VHF sources (power in dBW) 234 235 At this point, it may be noticed that EUCLID data are being presented as is, keeping in mind that some 236 events can be misclassified. Thus, ICs may be CGs, and vice versa [Cummins and Murphy, 2009]. In fact, 237 Warner et al. [2014] noticed that NLDN detections (same detection technology as EUCLID) following the 238 development of UPL from towers had a higher rate of misidentification. According to Azadifar et al. 239 [2016b], who also reported a higher rate of misidentification of EUCLID data for the Säntis, this can be 240 explained by the fact that ICC pulses with short current rise times are associated with leader/return 241 stroke mode discharges to an existing channel branch at some height above the tower tip. Another 242 reason for misclassification is related to the electric fields radiated from return strokes on tall towers, 243 which might have a shorter peak-to-zero time [Pichler et al., 2010]. 244 245 The time interval between the initiation of UL (first detected LMA source) and the first strokes at the 246 Säntis tower (first CG stroke according to EUCLID) was between 122 and 853 ms, with an average of 247 318 ms. Similarly, Schultz et al. [2018] reported a time span of about 200 ms (up to 600 ms) between 248 the upward progression of the first VHF source points from the LMA and the first NLDN detection at 249 the tower location. 250 8 Table 1. Characteristics of nineteen self-initiated upward lightning detected in three different dates. LMA columns depict time, number of sources, time of the first detected source and 251 duration of the event, area covered in km2 and upward-propagating leader polarity. Event numbers used through the text are shown in the far-left column. In some cases (*) an 252 insufficient number of VHF sources were recorded to estimate leader speed (and polarity). EUCLID columns display the number of strokes per event, the flash duration, the IC/CG 253 classification, the time of the first stroke and its estimated peak current, and the maximum peak current (and the corresponding stroke) Event 18 was a bipolar flash. The “delay” 254 column reports the time difference (ms), between the first LMA detection and the first Euclid stroke. The next three columns correspond to Tower measurements, showing the 255 number of current pulses (above 2 kA) and the maximum and the average peak current per event. Last columns correspond to wind speed and wind gusts measured at the Säntis 256 weather station. All times are in Coordinated Universal Time (UT ), and are given in the format HH:MM:SS. Local time calculation requires the addition of 2 hours. 257 258 Delay (ms) Date num. UPL num. IC/CG max. peak curr 1st LMA to puls.num. ave. sourc. polarity strokes classif. second kA (and stroke order) 1st Euclid (>2 kA) (N>2kA) (s) (ms) km2 (ms) (s) kA kA (ms) kA kA kA hh:mm (m/s) (m/s) 129-jun. 14:02:00 116 0.45 486 27.90 positive -- -- -- -- -- -- -- -- -- -- 14:00 5.8 11.6 214:06:12 51 12.86 136 6.90 positive 8249 1 / 7 13.27 -31.9 -42.2 [3] 414 12 16.2 7.4 14:10 6.6 13.8 314:08:39 25 39.51 182 10.69 positive 18 287 11 / 7 39.71 -10.9 -25.1 [4] 201 18 17.0 5.6 14:10 6.6 13.8 414:11:09 85 9.33 600 49.67 positive 30 856 18 / 12 9.51 -10.7 -36.1 [10] 177 30 16.1 6.6 14:10 6.6 13.8 515:05:42 18 42.63 134 4.78 unknown* 22 600 14 / 8 42.85 -18.9 -27.3 [5] 217 20 12.2 5.3 15:00 -- -- 615:10:52 10 52.41 522 3.45 unknown* 4 79 4 / 0 -- -- -- -- 3 5.5 4.3 15:10 -- -- 715:36:49 67 49.81 573 78.79 positive 39 241 10 / 29 50.56 -7.5 -31.4 [15] 746 42 10.6 5.2 15:40 -- -- 815:39:46 188 46.24 594 63.14 positive 47 577 31 / 16 46.41 -7.6 -17.9 [15] 170 51 7.2 4.3 15:40 -- -- 915:45:52 188 52.20 886 115.45 positive 30 681 16 /14 52.56 -7.5 -43.52 [11] 365 20 17.7 5.5 15:50 -- -- 10 15:47:31 66 31.37 268 21.12 positive 9148 5 / 4 31.49 -8.0 -25.5 [4] 122 11 15.5 5.2 15:50 -- -- 11 15:50:02 240 2.06 553 84.06 positive -- -- -- -- -- -- -- -- -- -- 15:50 -- -- 12 15:54:54 148 54.37 787 86.74 positive 18 481 8 / 10 55.22 -21.9 -42.9 [9] 853 20 14.9 5.9 15:50 -- -- 13 16:00:13 92 13.49 555 54.36 positive 15 329 11 / 4 13.64 -6.2 -26.56 [3] 148 17 11.2 5.8 16:00 -- -- 14 16:05:36 17 36.71 197 4.57 unknown* 7 105 7 / 0 -- -- -- -- 7 5.9 4.6 16:00 -- -- 15 10-jul. 20:48:57 6 57.73 12 0.05 unknown* 13 1543 7 / 6 57.93 -21.5 -55.6 [4] 196 14 23.1 8.1 20:50 10.6 19.8 16 20:51:45 17 45.07 145 4.95 positive 10 777 7 / 3 45.46 -27.4 -27.37 [1] 384 10 14.8 8.1 20:50 10.6 19.8 17 21:19:36 109 36.99 164 8.77 positive 596 5 / 0 -- -- -- -- 5 8.7 5.2 21:20 -- -- 18 14-jul. 13:25:39 20 39.63 188 9.29 unknown* 6 172 2 / 4 39.77 -7.69 -20.1 [2]* 140 4 9.0 7.6 13:30 13.0 19.3 19 14:00:12 84 12.14 148 14.89 positive -- -- -- -- -- -- -- -- -- -- 14:00 10.7 16.9 first duration area duration max curr w.gust wind speed LMA EUCLID first CG stroke Tower Met.Station hh:mm:ss 259 260 9 3.2. Leader speed and polarity 261 The leader polarity of the UL from Säntis has been inferred by using the time-distance graph [van der 262 Velde and Montanyà, 2013], which allows to separate simultaneous positive and negative leaders by 263 altitude and apparent speed of propagation. As an example, Figure 3a shows the upward leader of event 264 #9 in a time-distance representation, with the leader origin (first detection) as t=0. Dashed lines provide 265 a reference for slopes of leader traces corresponding to different 2-D radial speeds relative to the origin. 266 The leader is progressively moving away from the origin, at a rather constant height (source color) 267 yielding a slope corresponding to an average radial speed around the 2·104 ms-1 reference line, typical 268 of positive leaders. Figure 3b shows another example, this time event #11. The first upward leader 269 follows the slope corresponding to a positive leader. Interestingly, this event presented, 300 ms after the 270 +UPL inception, another leader that moved upwards to spread horizontally at about ∼6 km, this time 271 with an average speed close to the negative reference (105 ms-1). Columns 4 and 8 on Table 1 show the 272 number of sources per UL and the leader polarity according to the leader speed determined with this 273 method. In cases with few LMA sources, where the leader speed cannot be properly assessed, leader 274 polarity has been labeled as “unknown”. 275 3.3. Case study overview 276 June 29th 277 On this day, the sequence of Meteosat imagery showed convective cells developing in central and 278 southern Switzerland around 12:00 UT, which moved northeastward across the Säntis region during 279 the afternoon. With time, the group of cells ended organized as an MCS [Jirak et al., 2003]. Corrected 280 reflectivity from the Albis radar showed a nonlinear convective system [Duda and Gallus, 2010] 281 approaching from the SW and crossing the Säntis region from SW to NE. From 13:20 to 13:50 UT, the 282 convective cores of the MCS crossed the Säntis tower. Lightning flash rates (hereafter LFR) derived 283 from LMA and EUCLID showed maximum values of 29 IC flash min-1 (14:00-14:10 UT) and 4-5 strokes 284 min-1 (14:00-14:10 UT) respectively. 285 286 According to the LMA measurements, up to fourteen UPL were triggered by the Tower during this 287 episode, those having enough sources were all classified as +UPL. For eleven of them, the current 288 waveforms were measured at the Tower and the strokes detected by EUCLID (either IC or CG). The first 289 upward leader emerging from the Säntis tower tip mapped by the LMA was at 14:02:00 UT (event #1 290 in Table 1). It appears to have been an aborted leader since no discharges were reported by EUCLID. 291 Contrarily, the two following +UPL occurring minutes after (events #2 at 14:06:12 UT and #3 at 292 14:08:39 UT), ended in a sequence of return strokes recorded at the Tower and reported by EUCLID. 293 Figure 4 displays a basemap of corrected reflectivity (4 km height ASL) at 14:06 TU. The overlayed LMA 294 VHF sources show to clusters of activity. The first one corresponding to a convective core embedded in 295 the rainfall system, 25 km away from the Tower; the second group of VHF sources are UPL spreading 296 away from the Tower (events #2 and #3). 297 298 16 402 403 All in all, fourteen SIUL from the Säntis Tower were recorded during this episode over a time span of 404 two hours. All of them started with a UPL, spreading horizontal between 4 and 5 km (temperatures 405 between -5ºC and -10ºC). Events from 15:36 UT to 15:54 UT (#7 to #12) showed longer channels, 406 spreading and branching out toward the west, in opposite direction to the cloud system motion. 407 EUCLID detected a total of 248 strokes associated with these 14 SIUL, the number of detections per UL 408 ranging from 1 to 47, with an average of 19 strokes per flash. The 47 strokes maximum (31 IC and 16 409 CG) was detected by EUCLID for event #8. 410 411 July 10th 412 On this day, the sequence of Meteosat imagery showed convective cells developing in central France 413 around 12 UT. Like the June 29 episode, the multicellular system grew to become a MCS before 414 reaching the Säntis region around 18:30 UT. The most active core of the system crossed Switzerland to 415 enter south Germany by 20:30 UT, to the north of the Säntis region. By 20:15 UT, the MCS had reached 416 its maximum extension, with an area of more than 90,000 km2 (cloud shield with continuously cloud 417 tops below -52ºC, Jirak et al. [2003]). 418 With a higher spatial resolution, the radar observations showed the first convective cores appearing 419 west of the tower, in the area of the LMA, around 18:00 UT. The radar reflectivity imagery displayed 420 small convective cores crossing the Säntis region from SW to NE, embedded into a stratiform rain field. 421 Those small cores were irregularly distributed; appearing here and there and showing a short life-cycle 422 sequence of developing-maturity-decaying (30-45 min) all passing to the north of the tower. According 423 to the Duda and Gallus [2010] scheme, the system can be defined as a nonlinear convective system. 424 Around 19:45 UT, a more organized multi-cell system appeared west of the tower, in the area of the 425 LMA, and traversed above the tower west to east. At 20:30 UT, an active cell passed above the tower. 426 LMA and EUCLID reported the maximum lightning activity between 20:10 UT and 20:30 UT, with a 427 maximum LFR of 50 IC flash min-1 and 5 strokes min-1 respectively. Over time, the system progressively 428 organized and, around 21:00 UT, a line of convection was finally apparent in the radar base map to the 429 East of the tower. Then, during approximately an hour, the tower remained under the stratiform cloud 430 system that followed. 431 Three UL events were recorded during this episode (events #15, #16 and #17 in Table 1). They all 432 occurred in a period of 30 min approx., between 20:48 UT and 21:19 UT. The decreasing LFR indicates 433 that at that time convection was decaying in the LMA area of coverage, with the lightning activity 434 mostly limited to the Tower. Only a few IC were detected by the LMA, but far from the Tower, 435 apparently having no triggering effects on the three ULs. Event #15 (20:48:57) was poorly mapped by 436 the LMA and only a few sources were detected above the tower tip. However, 196 ms. after the first 437 LMA source, EUCLID reported 13 strokes related to the Tower (7 IC / 6 CG), all with negative peak 438 current with a maximum value of -55 kA. Event #16 was better mapped by the LMA and the time- 439 distance graph indicated a +UPL (not shown). EUCLID detected 10 negative strokes related to this 440 event. The best LMA-resolved +UPL emerging from the Säntis during this episode was event #17 441 (21:19:37 UT). In this case, the five IC strokes detected by EUCLID at the Tower were delayed by 353 442 ms. 443 444 17 a) b) Figure 8 a) As to Figure 6b but for July 10, 2017 at 21:19:37 UT b) As Figure 7 but for July 10, 2017 at 21:19:37 UT. 445 Similar to the June 29 episode, the basemap of corrected reflectivity at the time of the ULs showed an 446 extensive field of moderate reflectivity (25-35 dBZ), corresponding to the trailing stratiform part of an 447 MCS. The REF-XSEC related to event #17, displayed in Figure 8(a), along with the vertical temperature 448 profile, showed the bright band around 3 km height, 500 m above the Säntis tower tip. Reflectivity 449 values decreased with height, with the lowest values reaching 6-7 km ASL, indicative of a moderate 450 cloud vertical development. The overlay of the +UPL corresponding to event #17 shows how the 451 18 horizontal path of the channel was just above the melting level, a pattern observed in other UL studies 452 [e.g. Hill et al., 2013; MacGorman et al., 2014]. 453 The BB can also be inferred from the horizontal layer of WS in the HCP-XSEC (Figure 8b). In contrast to 454 the June 29 case, the vertical stratification on July 10 was less clear (and the bright band is not so clear 455 cut). Below the melting level, there was a mixture of rain (RN) and light rain (LR). Above, HCP showed 456 AG with some patches of RP. The patchy pattern may be a consequence of previous turbulences. 457 Finally, at higher levels, above the -20°C isotherm, the product identified traces of CR and VI. 458 459 July 14th 460 461 On this day, convective cores crossed the Säntis area from NW to SE. The convective system that 462 induced ULs from the Tower can be characterized as a cluster of cells [Duda and Gallus, 2010]. The two 463 ULs recorded at the Tower were isolated events, separated by more than half an hour. LFR over the 464 region of LMA coverage was lower than in the preceding events, with two periods of moderate activity, 465 showing maxima around 13:10 UT and 15:20 UT with a LFR of 5 IC min-1 and 1 stroke min-1, according 466 to LMA and EUCLID respectively. While other IC occurred in convective cores in the vicinity of the 467 Tower, the two ULs at the Tower (events #18 and #19), were isolated SIUL. 468 469 Event #18 was not very well resolved by the LMA; the 20 VHF sources show a quasi-vertical leader 470 reaching 5 km height. After a short delay (26 ms) EUCLID started to detect strokes at the Tower, four of 471 them classified as CG, all negative. Contrarily, event #19 was very well resolved by LMA, although there 472 were no current measurements at the Tower, nor EUCLID detections. In spite of what looks like a 473 branched UPL, in this case the lack of current measurements at the tower cannot confirm it has 474 emerged from the Tower. The basemap of corrected (Figure 9a) shows a leader heading west of the 475 Tower, branching once before the end. Besides, there were two other small branches at the beginning, 476 that could have also been leaders starting at the Tower. 477 478 In contrast with the June 29 and July 10 events, the SIUL took place under small cloud structures with a 479 cloud shield around 500 km2. Besides, although SIUL occurred with moderate reflectivity, this time 480 convective cores were present shortly after or nearby the Tower (Figure 9a). The XSEC-REF related to 481 events #18 and #19 showed moderate vertical development (6-7 km ASL). Vertical temperature profiles 482 situate the 0°C isotherm at 2700 m ASL, whereas the XSEC-HCP allows to estimate the melting level, at 483 around 3 km ASL (wet snow layer in Figure 9b). The overlay of event #19 shows the positive leader 484 developing horizontally just above the melting level. Above, there was mostly AG at the time of the 485 upward leader’s inception. Unlike previous episodes, RP were residual, and VI was found at lower levels, 486 even below the -10°C level. 487 488 19 a) b) 489 Figure 9 a) As to Figure 4 but for June 14, 2017 at 14:01 UT (event #19). b) As to Figure 7 but for June 14, 2017 490 at 14:01 UT 491 492 493 494 20 4.Discussion 495 4.1. Upward positive leaders 496 Studies on towers around the globe have reported a majority of ULs initiated by +UPL [e.g. Wang et al., 497 2008; Zhou et al., 2012; Yuan et al., 2017]. As an example, only 4% of the flashes at the Gaisberg tower 498 in Austria are initiated from the tower by a negative leader [Zhou et al., 2012]. This proportion is 499 around 12% at Säntis [Azadifar et al., 2016a]. In the present study, observations provide strong 500 evidence on the positive polarity of all reported upward leaders initiating UL from the Säntis. The 501 positive speed determined by the van der Velde and Montanyà [2013] method on the majority of UL 502 showed speeds around the 2·104 ms-1 reference, typical of positive leaders [e.g. Proctor et al., 1988; 503 Mazur et al., 1998; Shao and Krehbiel, 1996]. Moreover, the positive polarity is also supported by the 504 measurements of negative currents associated to these events at the Tower (example in Fig.2), along 505 with the negative polarity of the lightning pulses detected by EUCLID (Table 1). 506 An important question is whether positive breakdown itself produces locatable VHF emissions in +UPL, 507 or if the VHF sources associated with positive leaders actually originate from retrograde negative 508 breakdown (recoil leaders), which may occur close to the tips of positive leaders and be short in extent 509 [Mazur, 2002; Williams and Heckman, 2012]. Eventually, the relatively weak positive VHF sources can 510 be recorded when average current is higher than 3 kA and has significant pulse activity [Yoshida et al., 511 2010]. Besides, Edens et al. [2012] suggested that positive breakdown does produce low power VHF 512 emissions, but are only detectable with TOA techniques when no concurrent negative breakdown 513 occurs that produces strong VHF emissions, which is the case for isolated +UPL. Observations of +UPL 514 have been achieved by a small-baseline LMA configurations, like in Hill et al. [2012], Edens et al. [2012] 515 or MacGorman et al [2014]. Similarly, the LMA deployed around the Säntis nicely depicted UPL 516 emerging from the Säntis Tower. 517 Positive UPL are known to be highly branched [e.g. Mazur and Ruhnke, 2011]. In the present study, 518 branching was observed in 16 of the 19 events recorded. For the other three (events #6, #14, #15), the 519 paucity of sources did not allow to assess any branching. Although the recorded VHF sources were not 520 sufficient to reconstruct the branching on each UPL into detail, they were good enough to estimate the 521 height at which the first branching occurred. As Hill et al. [2012] pointed out, as branching generates 522 more channels, many of which are propagating simultaneously, its mapping losses accuracy due to the 523 time resolution of the LMA (80 ms per source location). Over time, the UPL typically appear as broad 524 regions of more diffuse source locations. Nonetheless, the first branching was located around 4 km in 525 all Säntis events, once the initial vertically-propagating continuous channels turned abruptly horizontal. 526 Positive leader modeling by Lalande and Mazur [2012] suggested that branching occurs as the potential 527 difference between leader tip and its environment exceeds a certain threshold. 528 4.2 Inferred cloud charge structure 529 In the absence of balloon-borne electric field measurements, the analysis on the cloud microphysical 530 and charge structure relied on the UPL propagation paths mapped by the LMA, the polarimetric 531 weather radar cross sections and the vertical temperature profiles. The display of a preferred path for 532 propagation by the UPL, and ultimately branching, is indicative of either high-electric fields [e.g., 533 Coleman et al., 2003, 2008], concentrated charge [Williams et al., 1985; Mansell et al., 2002], the 534 presence of characteristic hydrometeors in that range [Hill et al., 2013; Pikley et al., 2013] or even a 535 combination of the last two. Balloon-borne electric measurements carried on stratiform regions 536 21 [Stolzenburg and Marshall, 2008 and references therein] typically found a sharpest charge transition 537 associate to the largest charge density magnitudes just above the 0°C isotherm. Indeed, the largest 538 contribution to the BB is the change in dielectric constant enacted when ice phase hydrometeors melt 539 to become raindrops [e.g. Marshall and Rust, 1993; Shepherd et al., 1996]. Based on the positive polarity 540 of the UL triggered by the Säntis Tower, we assume that those channels propagated through a negative 541 charge layer, just above the melting level. Hence, in this case the underlying melting layer would be 542 positive. Moreover, one of the last UL observed on June 29 (event #11) presented, after the initial +UPL, 543 a negative leader (Figure 3b) that reached the -20°C level, where XSEC-HCP showed a transition from 544 AG to a mixture of VI and CR (Figure 7b). The recording of this upper negative leader by the LMA 545 revealed the existence of a positive charge layer above the main negative. All in all, HCP cross sections 546 show a general correspondence between the electrical structure drawn by the UL channels and the 547 stratified HCP categories. This overall microphysical structure is in agreement with the conceptual 548 model presented by Schuur and Marshal [2000A], where charge transitions coincide with peak 549 aggregation layers: particle separation due to fallspeed differences cause the charge transitions 550 immediately above the melting level (~1°C), and also near the -12°C isotherm. In our case, these key 551 temperatures are related to the transitions between WS and RP and RP and AG respectively. 552 Regarding the electrical structure, the radar cross section of Figure 7b provides the starting point for 553 synthesizing the charge structure. The layered nature of the HCP categories, continuous across the 554 stratiform region, along with the horizontal paths of the UPL suggests that the charge structure is 555 similarly layered. The overall electrical structure would consist of a positive charge in the isothermal 556 layer near the 0ºC (related to the melting layer), a main negative charge (~4km / -5°C) and a low- 557 density positive above (between -10ºC and -20ºC). This resulting structure fits well with the conceptual 558 model proposed by Stolenzburg et al. [1994] for the trailing stratiform regions of MCSs. 559 On the other hand, this charge structure would also match with the one presented in Marshall et al. 560 [2009] corresponding to the dissipation stage of the storms and linked to the end-of-storm oscillation 561 (EOSO) pattern. The EOSO consists of several polarity changes over a period of 30–75 min in the 562 electric field at the ground beneath decaying thunderstorms [e.g., Moore and Vonnegut, 1977; Marshall 563 and Lin, 1992; Williams et al., 1994; Pawar and Kamra, 2007]. The conceptual scenario for the EOSO by 564 Marshall et al. [2009] shows a progressive descent of the charge regions, which bring them closer 565 together. In turn, this would cause an approximation of the main negative charge layer to the surface, 566 favoring the +UPL inception. Unfortunately, in the present study there were no measurements on the 567 electric field at the ground allowing to observe the EOSO pattern. 568 Shindo et al. [2015] pointed out that upward lightning tended to occur when the altitude of -10°C is 569 below the 6 km height, condition that is fulfilled in our case studies. Yuan et al. [2017] added up the 570 relatively steady electric field distribution and a low charge height, as favorable conditions for the 571 initiation of upward leaders from tall man-made structures. From the current analysis, it follows that a 572 key feature for the +UPL inception is the proximity of a negative charge layer to the tower tip. Indeed, 573 the +UPL mapped by the LMA presented a short vertical path before turning horizontal, showing 574 evidence on the proximity of the negative charge region to the tower tip. If the opposite is the case, 575 where the tower would have been exposed to a main positive charge layer instead, the upward leaders 576 emerging from the tower should have been of negative polarity. However, the inception of negative UL 577 is more difficult, as they require electric fields more intense than positive streamers, by a factor of about 578 two about factor of two [Bazelyan and Raizer, 2000]. This could be the main reason why studies on 579 towers around the globe have reported a majority of ULs initiated by positive UPL. 580 22 4.3. The role of wind in SIUL triggering 581 At last but not least, the wind may play a role in the SIUL inception. A strong wind, not uncommon at the 582 top of very tall structures, can remove the corona shield, thus clearing the way for initiation of an 583 upward leader. According to Mazur [2016] this is the most probable explanation for the upward leader 584 inception in the absence of preceding nearby lightning flashes. For example, Wang and Takagi [2012] 585 noted that self-initiation occurred with higher observed wind speeds (or a rotating windmill) 586 compared with LTUL. Warner et al. [2014] suggested, during blizzard conditions in the US, that notable 587 winds may have played a key role in SIUL, by “stripping” away much of the corona discharge shielding 588 grounded tall structures. 589 Mostajabi et al. [2018] have analyzed, on a longer dataset of UL at Säntis, the influence of the wind 590 speed on the initiation of SIUL and LTUL. Results showed an increasing percentage of SIUL as a function 591 of the wind speed. For wind speeds of 12 ms-1 and higher, 30 of the upward flashes were SIUL, out of a 592 total of 31. Moreover, beyond 17 ms-1 only SIUL flashes were observed. Regarding the SIUL in the 593 present study, wind measurements from the MeteoSwiss weather station at Säntis, were available 594 (Table 1). Even though wind data did not cover all events, measurements at the beginning of each of the 595 three sequences of SIUL were available. Conditions were similar to those reported by Mostajabi et al. 596 [2018], suggesting that wind speed has a bearing on SIUL inception. 597 598 5. Concluding remarks 599 In this paper we have presented an analysis of comprehensive observations of self-initiated upward 600 lightning emerging from the Säntis tower, a lightning hotspot in Central Europe. Data from an LMA 601 network, deployed around the Säntis Mountain during the summer of 2017, along with polarimetric 602 weather measurements, allowed to infer the charge structure conductive to the self-inception of UL 603 from the tower. Common features on the observed SIUL are summarized on the following: 604 605  Upward-propagating positively-charged leaders (+UPL) mapped by LMA showed a short 606 vertical path, changing to mostly horizontal around 4 km height ASL. Branching was observed 607 in most of the +UPL, after they turned abruptly horizontal. The time span between the UPL 608 initiation and the first EUCLID detection located at Säntis ranged from 122 to 853 ms, with an 609 average of 318 ms. Almost all EUCLID strokes associated with SIUL were of negative polarity, 610 only one SIUL event was a bipolar flash. CG strokes average and median peak currents were - 611 16.7 kA and -15.8 kA, with a maximum peak current of -55.6 kA 612  Polarimetric radar measurements on the cloud shield showed a layered structure, continuous 613 across the stratiform region (at least in the vicinity of the tower). The “bright band” signature 614 allowed to clearly locate the melting layer (3-4 km height ASL) 615  Collocated LMA and radar cross sections showed a preferred path for the UPL horizontal 616 propagation, just above the melting level. 617 The layered nature of the radar-derived hydrometeor categories, along with the horizontal paths of the 618 UPL mapped by the LMA, suggests that the charge structure is similarly layered. The overall electrical 619 structure would consist of a positive charge in the isothermal layer near the 0ºC (related to the melting 620 layer), a main negative charge (~4km / -5°C) and a low-density positive above (between -10ºC and - 621 20ºC). 622 23 From the current analysis, it follows that a key feature for the +UPL inception would be a low charge 623 height structure, the main negative charge layer close to the tower tip. 624 625 Acknowledgements 626 The Säntis LMA campaign was a joint venture between the Electromagnetic Compatibility Laboratory 627 (EMC Lab) of the Swiss Federal Institute of Technology (EPFL), based in Lausanne (Switzerland), the 628 University of Applied Sciences of Western Switzerland (HEIG-VD), based in Yverdon, Switzerland, and 629 the Lightning Research Group (LRG) of the Technical University of Catalonia, based in Terrassa, 630 Barcelona (Spain). The Nowcasting Division of the Federal Office of Meteorology and Climatology of 631 MeteoSwiss provided data from the MeteoSwiss C-band radar network 632 This work was supported in part by the Swiss National Science Foundation (Project No. 633 200020_175594), the European Union's Horizon 2020 research and innovation program under grant 634 agreement No 737033-LLR, and the Spanish Ministry of Economy and the European Regional 635 Development Fund (FEDER) ESP2015-69909-C5-5-R and ESP2017-86263-C4-2-R 636 637 References 638 Austin, P. M., and A. C. Bemis (1950), A quantitative study of the ‘‘bright band’’ in radar precipitation echoes, J. Meteor., 7, 639 145– 151. 640 641 Azadifar, M., M. Paolone, D. Pavanello, F. Rachidi, C. Romero, and M. Rubinstein (2014), An update on the instrumentation of 642 the Säntis Tower in Switzerland for lightning current measurements and obtained results, in CIGRE International 643 Colloquium on Lightning and Power Systems, Lyon, France. 644 645 Azadifar, M., F. Rachidi, M. Rubinstein, V. A. Rakov, M. Paolone, D. Pavanello, & S. Metz (2016a), Fast initial continuous current 646 pulses versus return stroke pulses in tower-initiated lightning, J. Geophys. Res. Atmos., 121, 6425–6434, 647 doi:10.1002/2016JD024900. 648 649 Azadifar, M., F. Rachidi, M. Rubinstein, M. Paolone, G. Diendorfer, H. Pichler, W. Schulz, D. Pavanello, and C. Romero (2016b), 650 Evaluation of the performance characteristics of the European Lightning Detection Network EUCLID in the Alps 651 region for upward negative flashes using direct measurements at the instrumented Säntis Tower, J. Geophys. Res. 652 Atmos., 121, 595–606, doi:10.1002/2015JD024259. 653 654 Bazelyan, E.M. and Y.P. Raizer, (2000), Lightning Physics and Lightning Protection, Bristol IOP Publishing, 655 656 Becerra, M. (2014). Corona discharges and their effect on lightning attachment revisited: Upward leader initiation and 657 downward leader interception, Atmos. Res. 149 (2014) 316–323 658 659 Berger, K., (1967), Novel observations on lightning discharges: Results of research on Mount San Salvatore, J. Franklin Inst., 660 283, 478–525, doi:10.1016/0016-0032(67)90598-4. 661 662 Besic, N., Figueras i Ventura, J., Grazioli, J., Gabella, M., Germann, U, and A. Berne, (2016), Hydrometeor classification through 663 statistical clustering of polarimetric radar measurements: a semi-supervised approach, Atmos. Meas. Tech., 9, 4425– 664 4445, 2016 doi:10.5194/amt-9-4425-2016 665 666 Biggerstaff, M.I. and S.A. Listemaa, (2000), An Improved Scheme for Convective/Stratiform Echo Classification Using Radar 667 Reflectivity, J. Appl. Meteor., 39, 2129–2150 668 669 24 Brook, M., Nakano, M., Krehbiel, P. and Takeuti, T, 1982. The electrical structure of the Hokuriku winter thunderstorms, 670 J.Geophys. Res. 87, 1207-1215. 671 672 Coleman, L. M., T. C. Marshall, M. Stolzenburg, T. Hamlin, P. R. Krehbiel, W. Rison, and R. J. Thomas, (2003), Effects of charge 673 and electrostatic potential on lightning propagation, J. Geophys. Res., 108(D9), 4298, doi:10.1029/2002JD002718 674 675 Coleman, L. M., M. Stolzenburg, T. C. Marshall, and M. Stanley (2008), Horizontal lightning propagation, preliminary 676 breakdown, and electric potential in New Mexico thunderstorms, J. Geophys. Res., 113, D09208, 677 doi:10.1029/2007JD009459 678 679 Cummins, K. L. and M. J. Murphy (2009), An overview of lightning location systems: History, techniques, and data uses with 680 an in-depth look at the U.S. NLDN, IEEE, Trans. Electromagn. Compat., 51, 499-518 681 682 Diendorfer, G., H. Pichler, and M. Mair (2009), Some parameters of negative upward initiated lightning to the Gaisberg Tower 683 (2000–2007), IEEE Trans. Electromagn. Compat., 51, 443–452. 684 685 Dolan, B. and S.A. Rutledge, (2009), A Theory-Based Hydrometeor Identification Algorithm for X-Band Polarimetric Radars. J. 686 Atmos. Oceanic Technol., 26, 2071–2088, https://doi.org/10.1175/2009JTECHA1208.1 687 688 Duda, J. D. and W. A. Gallus (2010), Spring and Summer Midwestern Severe Weather Reports in Supercells Compared to 689 Other Morphologies, Wea. Forecasting, 25, 190–206. doi: http://dx.doi.org/10.1175/2009WAF2222338.1 690 691 Edens, H. E., et al. (2012), VHF lightning mapping observations of a triggered lightning flash, Geophys. Res. Lett., 39, L19807, 692 https://doi.org/10.1029/2012GL053666 693 694 Field, P. R., 1999: Aircraft observations of ice crystal evolution in an altostratus cloud. J. Atmos. Sci., 56, 1925–1941. 695 696 Flache, D., Rakov, V. A., Heidler, F., Zischank, W., & Thottappillil, R. (2008). Initial-stage pulses in upward lightning: 697 Leader/return stroke versus M-component mode of charge transfer to ground. Geophys. Res. Lett., 35, L13812. 698 https://doi.org/10.1029/2008GL034148 699 Foley, A.M., Leahy, P.G., Marvuglia, A., McKeogh, E.J., (2012), Current Methods and Advances in Forecasting of Wind Power 700 Generation. Renewable Energy, 37, 1-8. 701 Fuchs, B. R., E. C. Bruning, S. A. Rutledge,L. D. Carey, P. R. Krehbiel, and W. Rison (2016), Climatological analyses of LMA data 702 with an open-source lightning flash-clustering algorithm, J. Geophys. Res. Atmos., 121, 8625–8648, 703 https://doi.org/10.1002/2015JD024663 704 Germann, U., Boscacci, M., Gabella, M., & Sartori, M. (2015). Peak performance: Radar design for prediction in the Swiss Alps, 705 Meteorological Technology International, 42–45. 706 Grazioli, J., Tuia, D., and Berne, A.: Hydrometeor classification from polarimetric radar measurements: a clustering approach, 707 Atmos. Meas. Tech., 8, 149–170, doi:10.5194/amt-8-149-2015, 2015. 708 Helmus, J J and S. M. Collis (2016), The Python ARM Radar Toolkit (Py-ART), a Library for Working with Weather Radar Data 709 in the Python Programming Language. Journal of Open Research Software, 4: e25, DOI: 710 http://dx.doi.org/10.5334/jors.119 711 Hill, J. D., J. Pilkey, M. A. Uman, D. M. Jordan, W. Rison, and P. R. Krehbiel (2012), Geometrical and electrical characteristics of 712 the initial stage in Florida triggered lightning, Geophys. Res. Lett., 39, L09807, doi:10.1029/2012GL051932. 713 Hill, J. D., J. Pilkey, M. A. Uman, D. M. Jordan, W. Rison, P. R. Krebhiel, M. I Biggerstaff, P. Hyland, and R. Blakeslee (2013), 714 Correlated lightning mapping array and radar observations of the initial stages of three sequentially triggered Florida 715 lightning discharges, J. Geophys. Res. Atmos., 118, 8460–8481, https://doi.org/10.1002/jgrd.50660 716 717 25 Hobbs, P. V., S. Chang, and J. D. Locatelli, (1974), The dimensions and aggregation of ice crystals in natural clouds. J. Geophys. 718 Res., 79, 2199–2206 719 Jiang, R., Qie, X., Wu, Z., Wang, D., Liu, M., Lu, G., & Liu, D. (2014). Characteristics of upward lightning from a 325-m-tall 720 meteorology tower. Atmos. Res., 149, 111–119. https://doi.org/10.1016/j.atmosres.2014.06.007 721 722 Jirak, I.L., W.R. Cotton, and R.L. McAnelly, (2003), Satellite and Radar Survey of Mesoscale Convective System Development. 723 Mon. Wea. Rev., 131, 2428–2449, https://doi.org/10.1175/1520-0493(2003)131<2428:SARSOM>2.0.CO;2 724 725 Koshak, W. J., and Coauthors, (2004), North Alabama Lightning Mapping Array (LMA): VHF source retrieval algorithm and 726 error analysis, J. Atmos. Ocean. Tech., 21, 543-558. 727 728 Krehbiel, P. R., (1976), The electrical structure of thunderstorms, in The Earth's Electrical Environment, edited by E. P. Krider 729 and R. G. Robie, pp. 90- 113, Natl. Acad. Press, Washington, D.C., 1986. 730 731 Kumjian, M. R., (2013), Principles and applications of dual-polarization weather radar. Part II: Warm and cold season 732 applications. J. Oper. Meteor., 1, 243–264, doi:10.15191/nwajom.2013.0120. 733 734 Lalande, P. and V. Mazur (2012), A physical model of branching in upward leaders, J. Aerospace Lab, (5), 1–7. 735 Locatelli, J. D., and P. V. Hobbs, (1974), Fall speeds and masses of solid precipitation particles. J. Geophys. Res., 79, 2185–2197 736 737 Lu, W., L. Chen, Y. Zhang, Y. Ma, Y. Gao, Q. Yin, S. Chen, Z. Huang, and Y. Zhang (2012), Characteristics of unconnected upward 738 leaders initiated from tall structures observed in Guangzhou, J. Geophys. Res., 117, D19211, 739 doi:10.1029/2012JD018035 740 741 MacGorman, D.R., Rust, W.D.,1998. The Electrical Nature of Storms, 422 pp., Oxford Univ. Press, Oxford. 742 743 MacGorman D., S. Waugh, M. Biggerstaff, J. Pilkey, M. Uman, T. Ngin, W. Gamerota, D. Jordan, (2014), Coordinated LMA, 744 Balloon-borne Electric Field, and Polarimetric Radar Observations of a Triggered Lightning Flash at Camp Blanding, FL. 745 23rd International Lightning Detection Conference, Tucson, Arizona, USA 746 747 Maddox, R. A., (1980), Mesoscale convective complexes. Bull. Amer. Meteor. Soc., 61, 1374–1387. 748 749 Maddox, R. A., (1983), Large-scale meteorological conditions associated with midlatitude, mesoscale convective complexes. 750 Mon. Wea. Rev., 111, 126–140. 751 752 Manoochehrnia P. Schulz W. Rachidi F. Rubinstein M., (2008), Lightning statistics in the regions of Saentis and St.chrischona 753 towers in Switzerland. 29th International Conference on Lightning Protection, Uppsala, Sweden 754 755 Mansell, E. R., D. R. MacGorman, C. L. Ziegler, and J. M. Straka (2002), Simulated three dimensional branched lightning in a 756 numerical thunderstorm model, J. Geophys Res., 107, 4075, doi:10.1029/2000JD000244. 757 758 Marshall, T. C., M. Stolzenburg, P. R. Krehbiel, N. R. Lund, and C. R. Maggio (2009), Electrical evolution during the decay stage 759 of New Mexico thunderstorms, J. Geophys. Res., 114, D02209, doi:10.1029/2008JD010637. 760 761 Marshall, T. C., and B. Lin (1992), Electricity in dying thunderstorms, J. Geophys. Res., 97, 9913. 762 763 Marshall, T.C. and W.D. Rust (1993), Two Types of Vertical Electrical Structures in Stratiform Precipitation Regions of 764 Mesoscale Convective Systems, Bull. Amer. Meteor. Soc., 74, 2159–2170, https://doi.org/10.1175/1520- 765 0477(1993)074<2159:TTOVES>2.0.CO;2 766 767 Mazur, V., X. Shao, and P. R. Krehbiel (1998), “Spider” lightning in intracloud and positive cloud-to-ground flashes, J. Geophys. 768 Res., 103, 19,811–19,822, doi:10.1029/98JD02003 769 770