scieee AI-readable full text Open interactive document viewer

Life cycle assessment of a modular LED luminaire and quantified environmental benefits of replaceable components

Ferreira, Victor J.,Knoche, Sebastian,Corchero García, Cristina,Verma, Jai

Abstract

The lighting industry is facing a big challenge regarding the design of more sustainable lighting products. Although the development of LED technology has contributed enormously to their energy efficiency, more efforts are needed in reducing not only the energy consumption but also the use of key materials present in electronic components for a sustainable design. This can be achieved through new modular and configurable designs that can replace the generic LED luminaires that are disposable with a customized, sustainable product with high functional value, which should be supported by an assessment along its entire lifecycle to know the environmental performance to support the designs. This study conducts life cycle assessment models to quantitatively assist sustainable design decision-making of a novel LED modular luminaire's architecture. Firstly, a comparative LCA between a new luminaire and an existing product was performed to be used in an industrial environment. The results from this study showed a reduction of around 30% in the environmental impact categories that are more influenced by the energy consumption in the use stage (such as climate change and primary energy demand), whereas the resource depletion impact category associated with the elements was reduced by around 50%. The latter is mainly attributed to the reduction in the total circuit board area for the LED modules and the use of LEDs with less environmental burden made possible by eliminating the major contribution from the gold bond wire. Secondly, several scenarios are proposed based on modularity and replacement to change the LED luminaire life cycle towards more sustainability in the energy and material impact context. A scenario dedicated to analysing the optimal LED luminaire usage times in terms of energy and material efficiency is included. Two further scenario calculations treat the topic of replaceable components. One scenario investigates if exchanging the LED module regularly brings benefits by decreasing the primary energy demand category. The last scenario investigates the case of an LED module replacement because of a failure. The findings from the LCA models conducted serve as a guide to suggest eco-design strategies for the environmental sustainability of the new LED modular luminaire listed as several recommendations and reflections along its life cycle.

Full text

14,480 words Life Cycle Assessment of a modular LED luminaire and quantified environmental benefits of replaceable components Victor J. Ferreira1*, Sebastian Knoche2, Jai Verma1, Cristina Corchero1 1Catalonia Institute for Energy Research (IREC) Jardins de les Dones de Negre, 1, 2a pl., Sant Adrià de Besòs 08930 Barcelona, Spain 2TRILUX GmbH & Co. KG, Heidestraße 4, 59759 Arnsberg, Germany *Corresponding author: Dr. Victor J. Ferreira, Tel.: + 34 933 562 615; fax: + 34 933 563 802 vjferrei[email protected] Abstract The lighting industry is facing a big challenge regarding the design of more sustainable lighting products. Although the development of LED technology has contributed enormously to their energy efficiency, more efforts are needed in reducing not only the energy consumption but also the use of key materials present in electronic components for a sustainable design. This can be achieved through new modular and configurable designs that can replace the generic LED luminaires that are disposable with a customized, sustainable product with high functional value, which should be supported by an assessment along its entire lifecycle to know the environmental performance to support the designs. This study conducts life cycle assessment models to quantitatively assist sustainable design decision-making of a novel LED modular luminaire’s architecture. Firstly, a comparative LCA between a new luminaire and an existing product was performed to be used in an industrial environment. The results from this study showed a reduction of around 30% in the environmental impact categories that are more influenced by the energy consumption in the use stage (such as climate change and primary energy demand), whereas the resource depletion impact category associated with the elements was reduced by around 50%. The latter is mainly attributed to the reduction in the total circuit board area for the LED modules and the use of LEDs with less environmental burden made possible by eliminating the major contribution from the gold bond wire. Secondly, several scenarios are proposed based on modularity and replacement to change the LED luminaire life cycle towards more sustainability in the energy and material impact context. A scenario dedicated to analysing the optimal LED luminaire usage times in terms of energy and material efficiency is included. Two further scenario calculations treat the topic of replaceable components. One scenario investigates if exchanging the LED module regularly brings benefits by decreasing the primary energy demand category. The last scenario investigates the case of an LED module replacement because of a failure. The findings from the LCA models conducted serve as a guide to suggest eco-design strategies for the environmental sustainability of the new LED modular luminaire listed as several recommendations and reflections along its life cycle. Keywords: Life Cycle Assessment (LCA), Environmental Impact, Light Emitting Diode (LED), Modular LED Luminaire, Exchangeable LED Module, Eco-design 1. Introduction Energy efficiency has been one of the main concerns of the lighting industry to help reduce electric bills, which has led to the recent development of LED technology. For this reason, when thinking of the advantages of LED lighting, the first thing that comes to mind is energy efficiency. LEDs have contributed to savings of around 480 TWh of electricity and 200 million tons of CO2 emissions per year for European consumers in the last decade (LigthingEurope, 2015). However, the quantification of the environmental impact using the carbon footprint, or another metric is not only related to the energy consumption during the use, since it also has to take into account the energy and material recourses to produce the LED lightings. In other words, the overall sustainability of the LED lighting system should involve the efficient use of all resources, including energy and materials along the whole life cycle of the product. The shift from incandescent lamps to new LED lighting systems has brought energy efficiency. LEDs even outperform discharge lamps in most lighting applications by now. However, LED lighting products may require more energy in their manufacturing and challenges have increased in the recycling of the materials, which constitute the complex structure of electronic components in the LED systems. The environmental implications of electrical and electronic equipment are globally legislated. There exist several directives and regulations in the European Union (EU) now, such as WEEE (European Commission, 2009), RoHS (Directive 2011/65/EU, 2011) and Eco-design Directives (Directive 2009/125/EC, 2009), which are based on the life cycle approach. Just over 10 years ago, there was a change in the EU lighting sector as a result of the Ecodesign directive and the implementing measures. The regulation (Commission Regulation (EC) No 244/2009, 2009) on eco-design requirements was focused on non-directional household lamps, establishing requirements on energy efficiency as well as for functionality. Since then, the LED lamps were encouraged to replace incandescent lamps since they fulfill the energy efficiency requirements. Currently, the EU lighting sector is facing another change regarding the new regulation for Eco-design requirements of light sources, which can be considered as the main tool to deliver the EU’s circular economy strategy. Circular economy requirements are included in the ecodesign rules for a complementary sustainability strategy. The rules introduce performance requirements and mandatory removability of light sources and control gears contained in products in case a documented technical justification stating appropriateness in doing otherwise is not provided, which would bring major changes for producers and end-users of lighting products. On the other hand, fundamental changes have also been made on the energy efficiency requirements related to the banning of the T8 linear fluorescent lamps and Compact Fluorescent Lamps (CFL) with integrated control gear in the next years (Official Journal of the European Union, 2019). Most of the currently remaining halogen lamps continue to be allowed on the EU market. The circular economy approach has the potential to lead to benefits for the environment in the lighting industry, as well as for the consumer and the economy. Improving the material efficiency and serviceability for the lighting products is believed to lead to greater energy savings, waste reduction, recycling targets met, longer lifetimes, improved luminaire performance due to upgrades, and the creation of jobs and business models. All of these aspects of the circular economy have the potential to be achieved according to the guidelines established by LightingEurope (LightingEurope, 2017), which has worked closely with regulators. Life Cycle Assessment (LCA) is a tool underlined to be used in circular product development (Szita, 2017) as well as in the design of new products considering the environmental perspective. Eco-design is characterized by the life cycle thinking and it is encouraged to the designers and engineers to perform the LCA as it is one of the most suitable and factual ways to analyse the entire life cycle of the product based on a multi-criterion calculation (Rio et al., 2010). Centred around the energy-savings background, a number of LCA studies on lighting products have been performed, such as the estimation of benefits due to energy efficiency improvements in street lighting systems in Indonesia (Irsyad and Nepal, 2016) and the potential of LEDs to reduce lighting energy use and CO2 emissions in Finnish households (Tetri et al., 2014). On the other hand, comparative LCA studies of different lighting solutions have been carried out, such as those of incandescent, CFL and LED (Clarke-Sather et al., 2016; Elijošiutė et al., 2012; Shahzad et al., 2016), various lighting technologies for greenhouse crop production (Zhang et al., 2017), lighting for offices (Principi and Fioretti, 2014) and other lighting technologies (Tähkämö and Dillon, 2017). Tähkamö et al (Tähkämö et al., 2012) compared different LED lighting sources to highlight the importance of the study of their life cycle as a whole where the major environmental hot spots are identified. Few of the above-mentioned studies do present an updated comprehensive comparative LCA to guide eco-designers, which is useful to assess and compare the environmental impacts of two or more LED lighting product designs. In one comparative LCA study (Casamayor et al., 2017) regarding design perspectives for LED lighting, the environmental impacts of a newly designed eco-LED product and a commercialised LED-based product were assessed and compared. The newly designed product was found to have a 60% lower environmental impact than the existing lighting product in all scenarios, and recommendations for the eco-design of LED lighting products were proposed. In most of the studies, usage is the most impactful stage from an environmental viewpoint, however, it is important to note that the useful life of the LED products is heavily influenced by manufacturing faults, operating conditions, and lighting product’s design (US DOE. US Department of Energy., 2009). Continuing along the same lines, another study (Casamayor and Su, 2020), stressed on prioritising the application of ecodesign strategies towards the manufacturing stage. The study concluded that the eco-design strategies such as reducing the amount of virgin materials used, especially critical materials, or use recycled materials as much as possible, in the manufacturing stage should be done, along with reducing the number of manufacturing processes which lead to a high environmental impact. For this study, the sustainability of a new LED Luminaire design is evaluated from the environmental point of view compared to an existing product. The new luminaire is based on a modular architecture, is dimmable and customizable, that considers the aspects under the new eco-design regulations within the context of circular economy. In both cases, the term LED luminaire refers to a lighting product that includes the LED light source and necessary electronic control gear; not only the housing. The evaluation follows the LCA methodology based on the recognised standards of ISO 14040 (ISO-14040, 2006) and 14044 (ISO-14044, 2006). The system boundaries defined to conduct the LCA study, include the raw material extraction, luminaire production, installation and use, transportation, and end of life (EoL) stages. Three EoL scenarios following the cut-off EoL approach from the worst case to a best practice are studied considering the possibility of the materials either being disposed-off at landfills or getting sent to incineration plants or the third scenario of getting recycled. Studies focused on the waste management of lighting are limited. The environmental impacts at EoL stage are often neglected due to the dominance of the use phase impacts, as well as the lack of economic and technical information on recycling processes (Mizanur Rahman et al., 2017). Nevertheless, some studies consider this stage, including recycling aspects of different lamp designs. For example, (Apisitpuvakul et al., 2008) examined the life cycle impacts of increasing the recycling rate of spent fluorescent tubes in Thailand. There, fluorescent tubes are either recycled for glass cullet or disposed of after mercury treatment. Their study found that recycling could reduce environmental impacts across all indicators by 85%, which is directly proportional to the reduced usage of sodium sulphide and cement in mercury treatment. (Thavornvong W, 2016) compared the environmental1impacts of different waste management scenarios for a T8 linear fixture fitted with either fluorescent lamps or LED lamps in Thailand. Similarly, (Dzombak, 2017) evaluated the environmental impacts of different EOL pathways for an LED street light, using a bill of materials created based on product teardowns. However, it has been established that the end-of-life performance does substantially get affected by the implementation of more circular guidelines on the process level, such as product level recovery, component level recovery, and material level recovery (Rahman et al., 2019). The study aims to provide insights in the field of comparative LCA of LED luminaires to guide the design decision-making of sustainable modular LED luminaires. The LCA results are used to analyse the optimal LED usage times in terms of energy and material efficiency considering the LED flux degradation that leads to limited luminous energy. For the calculation of the efficiencies, material and energy resources consumed are measured through the environmental metrics as the depletion of non-renewable mineral reserves (quantified under the reference unit kg Sb eq) and consumption of both renewable and non-renewable primary energy sources in MJ. On the other hand, the LED module of the new luminaire designed for exchangeability is analysed to inquire if this characteristic leads to more sustainability from a life cycle perspective. 2. Methodology The environmental performance of the linear LED luminaires under-study is conducted following the LCA methodology from a cradle-to-grave approach. This approach starts with the gathering of raw materials coming from the earth for the product manufacturing or production phase, includes the transportation and the usage, and then concludes with the EoL stage. Therefore, the LCA evaluates all stages of the product life considering the operation of each stage leads to the next. The accumulative impacts from all stages allow providing the estimation of the LCA in the environmental product life cycle. On the other hand, when the environmental impacts associated with each stage or phase are known separately, it allows detecting hotspots that should be addressed to minimize the impacts. This provides useful information to make improvements from an eco-design viewpoint (Navajas et al., 2017) and support the circular economy for more sustainability (Haupt and Zschokke, 2017). The different phases are as follows: Raw Material extraction: This first stage considers the emissions and resource usage associated with several raw materials going into the final product and transportation. It is possible to adjust the impacts associated with the production, considering if a component is made from recycled materials or is replaced by other ones with less impact. Production phase: This phase can take into account the raw materials defined above and can consider the energy and emissions associated with manufacturing the final product. The relevance of these parameters in the environmental impacts allows also for taking measurements or strategies to achieve environmental improvements. Transport: The transport is mainly related to the distribution of the materials and product alongside the production phase up to the installation point, the use, and EoL phases. If the transport is thought to be dominant, then detailed transportation modelling should be carried out to know its impact on the life cycle of the product. For many products, for instance, lighting products, the transport impacts have a small contribution in their life cycle (Lozano-Miralles et al., 2020), but that doesn't mean it is futile to include the transportation phase in the study to quantify the total impact of the product. The use phase: This phase is associated with the consumption of electricity to produce the light in the luminary systems. The adjustment of the impact can be achieved in this phase through the means of technologies offering increased energy efficiency and renewable energy sources. Moreover, a consistent model describing the energy consumption should be developed to compare different products. EoL: This phase reflects what happens to the product when its functionality is over in its life cycle. It is not very easy to define what is within and outside the system boundaries at the EoL, since the real disposal of products might be difficult to know. However, some scenarios (landfill, incineration, recycling, etc.) and existing approaches can be considered to define where this phase is cut, also considering the available data to calculate the most reliable impacts. The LCA analysis can show the best practice at the EoL from an environmental perspective to give design suggestions at the beginning of the life cycle stage (production). For instance, easy dismantling of product components to avoid landfill/incineration and end up getting recycled or even a possible second life or reuse. The LCA analysis through the above life cycle stages can help in decision-making to compare two or more products, processes, or services. On the other hand, the environmental improvements associated with the design of the product can be determined by comparing its life cycle with the conventional one. However, the LCA studies should be conducted using the same criteria, system boundaries, and recognised methods for comparison purposes. The cradle-to-grave LCAs of the studied luminaires comply with the International Organization for Standardization’s guidelines for LCA as documented in ISO 14044 (ISO-14040, 2006) and ISO 14044 (ISO-14044, 2006). The methodology consists of four phases: 1) Goal and scope definition: The product, process, or activity are described and defined in this phase where the functional unit, system boundaries, and methodological considerations should be also set up. 2) Life Cycle Inventory (LCI): This is the data collection phase characterized by the modeling of flows in terms of materials and energy for the product under the study. The collected data in this phase involve all the environmental and technical quantities for all relevant unit processes within the system boundaries. 3) Life Cycle Impact Assessment (LCIA): It quantifies the overall impact for each impact category assessed. This phase calculates the potential for specific environmental burdens. Several impact categories can be assessed, as well as multiple characterization factor models to quantify the categories. 4) Interpretation: The previous three phases are linked with each other and also in this last phase named interpretation. This is to ensure that the goal and scope of the study have been met. The results of the inventory analysis are evaluated along with the impact assessment to show the environmental-behavior related results of the preferred product, process, or service. Assumptions in the analysis are also considered in the interpretation phase. Firstly, a study is carried out to compare two luminaires in an industrial setting from an environmental point of view following the LCA methodology described above, Benchmark linear LED Luminaire and New linear LED Luminaire hereinafter referred to as BL and NL, respectively. The BL is an existing product for industrial lighting, and the NL is an improved design for the same application, that can replace the BL one by one. The essential differences to the BL is a material optimized design, the usage of LEDs on the latest state of technology (with flip-chip technology instead of gold bond-wire technology), and the option to make exchangeable the LED module, hereinafter referred to as LEDM, by use of a simple connector. This comparative study is presented in section 3 and considers the use of the luminaires over their complete nominal lifetime. A second study, following the same LCA perspective, is developed in section 4 to show several scenarios to change the luminaire life cycle towards more sustainability. The first scenario ignores the nominal lifetime of the luminaires to determine the optimal usage times in order to obtain the maximum energy efficiency or the maximum material efficiency. Although it is a rather theoretical calculation, it shows that energy efficiency a material efficiency cannot be optimized simultaneously, and also shows that the optimal usage times differ from the nominal product lifetimes. Then, the effects of regular LEDM replacements were investigated in the second scenario, which are intended to enhance the energy efficiency but lead to lower material efficiency. A final scenario calculation compares different strategies to handle cases where a luminaire fails: Replacing the complete luminaire or introducing LEDMs with connectors that allow replacing the LEDMs only. This scenario is based on estimates of the failure rates and shows that replacing complete luminaires is not always the worst option. In particular, the last two scenario calculations address the question if luminaires should be modular, allowing separate replacements of the LEDMs and control gears. To quantify the effects, the additional material used in a modular design (e.g. for connectors) must be balanced with the expected material savings. The latter mentioned material savings depend on the scenario, which is expected for replacements of luminaires. The reasons for replacements could be maintenance (a scheduled replacement to restore the luminaires’ energy efficiency) as considered in the third scenario, or repair (to fix an unexpected failure). Based on the above studies, eco-design strategies considered along with those life cycle stages of the LED modular luminaire are provided finally in section 5 as recommendations for a more sustainable modular LED luminaire. 3. LCA of linear LED luminaires 3.1 Goal and scope definition The goal of the study is to calculate the life cycle environmental impact of a NL with modular characteristics to be compared with a BL, as shown in Figure 1. Figure 1 Characteristics of the BL Both luminaires are modelled in an industrial setting. The research is focused on the identification of environmental aspects between the two luminaires pertaining to savings in the material use, type of material, energy consumption, and waste production, which can be reduced to lower the environmental impact of the NL. The overall goal helps investigate scenarios to steer the luminaire’s life cycle design towards more sustainability considering the energy efficiency and material efficiency of both lighting systems from an environmental perspective as well as from the serviceability aspect of the luminaire. To support this aim, the LCI results will be used in section 4 for scenario calculations that address optimal usage times (for energy efficiency and material efficiency), regular replacements of LEDMs in order to increase the energy efficiency, and comparing a repairable luminaire to a non-repairable luminaire that has to be replaced as a whole in case of an LED failure. The functional unit for the LCA studies is an illuminance of 300lux in a lighting system for an industrial hall (120m x 60m) constituted by 369 luminaires. The defined lifetime for the luminaires is 70,000 hours. This lifetime was chosen considering the L80 specification for the luminaires, indicating the lifetime at which the LED light output reaches 80% of its initial output. All the information about inputs and outputs is associated with the functional unit if not stated otherwise. The cradle-to-grave system boundaries are shown in Figure 2 including the energy inputs and emissions and waste outputs for all stages in the life cycle, including raw material extraction, production of each component of the LED luminaire, assembly of the luminaire, spare parts, installation, the use of the luminaires in a lighting system and disposal scenario. The NL has an exchangeable LEDM with plugs fixed to be easily connected/disconnected by customers. With this new characteristic, this luminaire presents two components that can be repaired, the LEDM and the LED control (LEDC), which avoids replacing fully a luminaire when these components fail. On the other hand, the LEDC can only be repaired in the BL. Therefore, the stage intended to produce the spare parts (Figure 2) is to indicate the production of LEDC spare and the replaceable luminaire for the benchmark lighting system; or the LEDC and LEDM spares for the lighting system made up by NLs. Besides that, the plugs, to give the exchangeability functionality to the LEDMs, are also included in the model. The transportation is only included for transport to the installation site and transport to the final disposal. The distance to installation is assumed in 30 km by lorry as a study carried out by Tähkämö et al. (Tähkämö et al., 2013). Whereas, the transport distances for final disposal were estimated considering a collection and sorting management of lighting products by the Ambilamp association located in Spain (Ambilamp, 2020). In this sense, it was estimated at 60 km to the waste sorting facility and 80 km from the sorting facility to the treatment facility. The packaging of both luminaires has not been considered and is assumed to be the same for both luminaires. The production of industrial machinery and equipment is also not included in the system boundary, nor is the transportation within the manufacturing plant. Figure 2 System boundaries for the LCA studies 3.2 Life Cycle Inventory analysis The life cycle stages are considered for the inventory including the bill of materials for the luminaires, the data for the electricity consumption in the use phase, and the EoL stage. Since a luminaire is constituted by different components, they were categorized as depicted in Table 1, where their main materials are also shown. Bill of material: Table 1 shows the difference in the material bill for the BL and the NL as a result of applying the design strategies. Raw material extraction Luminaire production Spare part production Assembly Installation Use in the industrial setting EoL Cradle Gate Grave LandfillIncineration Recycling Energy inputs Emissions and waste outputs System boundaries Table 1 Categorization of components and material bill per one luminaire Category Component Material NL (g) BL (g) Wiring Wires Copper 42.80 42.80 LEDC Circuit Board (CB) 30.60 30.60 Capacitors, Conductors, Varistor Cooper, gold, lead, silver, etc. 112.50 112.50 Plastic housing for Electronic Control Gear (ECG) PET 4.35 4.35 Metal housing for ECG Steel 93.80 93.80 Mechanics Metal parts Steel 164.00 103.40 Plastic parts ABS 27.07 91.90 Screws Stainless steel --- 19.10 Gear tray Steel 758.00 1044.30 Trunking Steel 1648.00 1648.00 LEDM CB Copper, gold, lead, silver, etc. 74.00 251.40 LED SMD 3.45 6.6 Plugs Copper, Silver, Tin 4.50 --- Optics Optical element PMMA 344.00 531.30 End piece to optical element PP --- 2.94 Total 3307.0 3976.4 The changes carried out in the NL are part of eco-design characteristics as recommended in section 5. The LCA studies for the BL as well as literature show that the production and use are the stages with higher impact. Therefore, materials savings and energy efficiency improvements were the main changes established by the designers to be applied to the new LED modular luminaire. Under this premise, the main modifications were in the mechanic parts, LEDM, and optics, resulting in material savings. The LEDC and wiring are the same as in the BL, because the amount of wires is mainly determined by the luminaire length, and the LEDCs are market standard components. The material reduction in the mechanics is mostly attributed to the gear tray in the NL to meet the same functionality as in the BL. Plastics in optics were also reduced by about 35%, being the PMMA, the amount of plastic got notably reduced. Figure 3 and Table 2 show the LEDM of the BL and the NL in comparison. Besides the different use of LEDs, the CB width has been decreased in the NL. This is not a consequence of the modularity in design, but it was enabled by the use of more efficient LEDs that require less cooling and heat spread by the copper layers of the CB. For the LEDM of the NL, there exists a further variant with a connector, enabling LEDM exchange, which almost has the same CB area. Figure 3 Comparison of the LEDMs of the BL (left) and NL (right) The changes in the LEDM in the new LED luminaire allowed to reduce the total area of CB since the width was reduced (Figure 3), contributing to saving materials by around 70%. The Table 6 Electricity grid mix used in the LCA (EU-28 mix). Source: GaBi Professional Database(Thinkstep, 2015) Energy source Shares (%) Nuclear 27.0 Natural Gas 16.0 Hard Coal 14.0 Hydro 12.0 Lignite 10.0 Wind 9.0 Photovoltaic 3.2 Biomass 2.8 Biogas 2.1 Heavy fuel oil 1.9 Waste 1.4 Coal Gases 1.0 In order to improve the results, further work should focus on improving the data quality regarding the electronic components and evaluating the potential for precious materials’ recovery from the CB and LED SMD. Precious metals can be extracted selectively from CB through hydrothermal methods, as used for Cu and Au recovery (Birloaga et al., 2013; Liang et al., 2013). A study has shown that recovery is possible for fairly good yields of Cu under the conditions of a fixed-bed reactor and vacuum pyrolysis of CB (Long et al., 2010). The results showed 99.5% Cu extraction with a recovery quality of 99.86 percent of the total weight of the CB. However, these are not yet common practices as recovery of precious metals from luminaires also needs to be economically feasible. 3.4 LCA results The environmental impacts of the production, use and disposal of the NL and BL in the industrial lighting systems were quantified for each impact category assessed. The results are shown as percentage contribution normalised to the BL in Figure 5 and as absolute environmental impacts in Table 7. It can be observed that the impact of the use phase in both lighting systems ranges from 98% to 99% for all impact categories, except for ADPe. The use phase is dominant due to the electricity consumption. In contrast, the contributions of the production stage range from 0.5 and 1%, except for ADP. The high environmental impact dominated by the use phase has been also observed in other type of lighting products such as incandescent lamps, where the usage is the phase responsible for the greenhouse-gas emissions (kg CO2 eq), with over 99% coming from the generation of the electricity while less than 1% attributable to the production phase (Elijošiutė et al., 2012). Leena Tähkämö et at.(Tähkämö et al., 2014) also reported high environmental impacts in the use phase of the fluorescent lamps used in industry, between 95 to 99% for the GWP, EP and AP categories. For lighting products based on LED, Hao et al. (Zhang et al., 2017) reported that the use phase of a 650-W LED lighting system used for a greenhouse crop production, dominates all environmental impact categories due to the electricity consumption. The results of the EoL scenarios are shown (Figure 6) in terms of percentage normalised to the worst case (100%), which had a higher impact in all categories, except the GWP. In this impact category the best practice scenario resulted in having a higher impact (around 227%) followed by the mixed scenario (188%) with respect to the worst case. This fact is attributed to the impact for incineration of PMMA and ABS because of the CO2 emissions generated during this treatment process. Electricity production from the material incineration process as an LCA credit is not considered in the system studied. This is in order to be consistent with the cut-off approach used in this study, which follows the philosophy that a producer is fully responsible for the disposal of its wastes, and that any credit for the provision of any recyclable materials is not received. Moreover, it can be seen that the best practice scenario exhibits lower impact in ADP elements, PE, ADP Fossil, AP and EP as compared to the worst and mixed case scenarios. This could be achieved by ensuring that the collection and sorting of lighting products is done separately from the general waste collection, which is mandatory for all member states in Europe. In this sense, the lighting industry should follow a target of 85% for the collection of luminaires for recycling (Eurostat, 2019). Figure 5 Comparative percent contribution of production, use and EoL to each impact category for the lighting system NL and BL 0 20 40 60 80 100 BL NL BL NL BL NL BL NL BL NL BL NL ADPe ADPf AP EP GWP PE (%) Luminaire production Spare part production Use EoL Table 7 LCA environmental impact comparison of the luminaire systems studied Luminaire production Spare part production Installation Use EoL Total ADPe BL 5.06E-01 1.89E-03 2.36E-07 1.55E-01 2.80E-05 6.62E-01 NL 1.96E-01 7.22E-04 2.36E-07 1.14E-01 1.12E-05 3.11E-01 ADPf BL 1.02E+05 3.47E+02 8.39E+01 5.22E+06 1.04E+03 5.32E+06 NL 4.24E+04 1.10E+02 8.39E+01 3.83E+06 5.83E+02 3.88E+06 AP BL 3.18E+01 1.09E-01 1.84E-03 1.38E+03 3.16E-01 1.41E+03 NL 1.08E+00 4.11E-02 2.59E-02 1.01E+03 1.54E-01 1.01E+03 EP BL 2.59E-03 7.01E-03 6.03E-03 1.29E+02 6.53E-02 1.29E+02 NL 8.18E-01 2.59E-03 6.03E-03 9.48E+01 2.62E-02 9.57E+01 GWP BL 8.66E+03 2.92E+01 6.00E+00 4.88E+05 9.24E-02 4.96E+05 NL 3.41E+03 9.53E+00 6.00E+00 3.58E+05 6.57E-02 3.62E+05 PE BL 1.22E+05 4.18E+02 8.47E+01 1.23E+07 1.46E+03 1.24E+07 NL 5.15E+04 1.37E+02 8.47E+01 9.05E+06 8.84E+02 9.10E+06 New strategies and designs of luminaires would help the consumer to dispose the product correctly, which would position the best practice scenario as the most likely case. In order to improve this further, investigation into the recovery of precious metals from the electronic components is required. Figure 6 Results of EoL scenarios for lighting system In the overall environmental performance of the luminaires, it was observed that the EoL stage contributes less than 1% in all impact categories as seen in Figure 5. The results associated with the three EoL scenarios studied do not change the significance the EoL in the entire luminaire life cycle. The EoL average of environmental impacts continues to be under 1%, regardless of the EoL scenario. When comparing the luminaires, it is noted that the overall environmental performance of the NL is better than the BL (see Figure 5), since energy savings in the use phase are achieved because of the efficacy and the daylight control implemented, which makes a reduction of around 27% for the ADPf, AP, EP, GWP and PE impact categories. On the other hand, the materials and energy savings make its total ADPe (3.11E-01 kg Sb) lower than BL (6.62E-01 kg Sb), achieving savings of 53%. The most contribution to decreasing the ADPe category comes from material savings attributed to the strategy of the new configurable design in the NL. The reduction of materials, mainly Gold in the LEDM of the NL, influences directly and to a greater extent, this indicator, since the depletion of non-renewable mineral reserves is avoided. On the other hand, the saving of energy in the use phase allows also for reduced material resources in upstream processes to produce such energy. The result shows that the use phase in the ADPe category of the BL contributes 0.155 kg Sb eq while the NL 0.114 kg Sb eq, which leads to a reduction of 26% (see Table 7). With the implementation of a light management system, or further improvements in the energy efficiency of LED luminaires, and the integration of more renewables on the grid, the materials may become even more significant in their contribution to the overall environmental impact. Figure 7 ADP element distribution by components. Because of this, the production phase was further investigated to know the distribution by components in the ADPe category, as shown in Figure 7 for both luminaires. It can be seen that LEDM and LEDC are the components with the main contribution in both luminaires for the ADPe category, being the contribution of LEDM by 75% in the BL and 37% in the NL. The LEDM is made up by LEDs and CB according to the categorization defined in this study. Both of them have a similar environmental contribution in the LEDM of the BL (LED SMD is 1.2 times of the CB). Under this context, the use of LEDs with less gold in the NL reduces considerably its impact, making now the CB as the highest impact contributor. The use of less LEDMs reduces the total area of CBs in the NL also contributing to decrease the overall ADPe in the production stage by 60% with respect to the Bench, which has resulted in savings for the consumption of non-renewable natural resources. When analysing in detail the material impact per each component (LEDs and CB) in the ADPe category of both luminaires, it is observed that Cooper is the metal with the highest impact contribution (56%) per 1 sqm of CB, followed by gold (25%), silver (12%), lead (6%) and other elements (1%). On the other hand, gold being present in LED SMD of BL (based on Au bondwire) is the dominant metal in this indicator, since its impact is 99% of the total impact around 2.43E-06 kg Sb eq per LED SMD piece. In contrast, the picture changes dramatically 0.00 0.10 0.20 0.30 0.40 0.50 BL NL kg Sb eq LEDC Mechanics Optics Wiring LEDM for the LED SMD Flip Chip that has an impact of 1.96E-09 kg Sb eq per LED SMD piece. This is three magnitude orders less than the LED SMD of the BL, due to the lower amount of Gold only contributing 14% of the total ADPe impact. It is worth noting that REE are not addressed in the ADPe characterization model CML 2001- Jan. 2016 (Guinée et al., 2002), i.e., characterization factors (CFs) for REE are not included, thereby flows are not characterized in the impact assessment. The CFs were excluded during the revision of ADP in 2002 (Van Oers et al., 2002) due to assumptions that resulted be imprecise for the REE’s CFs. Materials in mechanics and optics have low contribution with optics being practically negligible since they consist of PMMA plastic. The material savings in mechanics only contribute to reducing the ADPe by around 2%, precisely because of the low impact contribution of mechanics (5-10%). As mentioned before, the LEDC and Wiring are the same for both luminaires. These are the next ones having an important contribution in terms of impacts from components. The LEDC is constituted by electronics (capacitors, conductors, varistors, etc.), which contribute mostly to the impact of the LEDC (around 78%), whereas the CB contributes only 22%. Metals as copper, gold, lead and silver are the main contributors to the ADPe impact associated with the electronics. This may be critical since the environmental burden to produce these metals from virgin sources is high (Fashola et al., 2016). Thereby the recovery of those materials with the required quality to be used in the electric products would bring environmental benefits and boost the shift to a circular economy for the luminaires. Sensitivity and uncertainty analysis The LCA results showed that the luminaire production is the stage that contributes significantly to the environmental profile in the ADPe category. Therefore, it has been considered interesting to perform a sensitivity analysis to verify which components have the greatest influence on these results, as they could provide information to focus attention on the points where efforts should be made to reduce their relevance on the environmental performance of the luminaire. On the other hand, several uncertainty sources, mainly linked to methodological choices, initial assumptions, such as allocation rules, system boundaries and impact assessment methods, as well as quality of the available data may affect the results of an LCA study (Cellura et al., 2011). Experience also shows that uncertainty related to the inventory can be significant for LCA studies (Baker and Lepech, 2009).Thereby, an uncertainty assessment associated with the inventory is considered in this study for testing the robustness of results, especially when two products are compared, such as recommended by the standard ISO14040. In this light, a conventional sensitivity analysis was conducted to find out how sensitive the model was to changes in all the input parameters. To do this, a random variation of the inventory values relative to the luminaire production stage in the range ± 50% was performed, and the influence on the results was studied. Those parameters that caused a variation of at least 0.15% were selected for a Monte Carlo analysis to show a range of uncertainty with 95% confidence in the results. Both the sensitivity and Monte Carlo analyses were performed using the Analyst Tool of GaBi ts. The contribution to the uncertainty of the selected parameters was assessed by means of 1000 runs of the Monte Carlo simulation for the ADPe category. Random values from the probability distribution of each parameter were selected in each run and a forecast normal distribution for each parameter was obtained between the 10th and 90th percentiles. Figure 8 shows the results of this sensitivity analysis for ADPe for both luminaires considering the contribution of several parameters to the overall results of this indicator. Figure 8 Sensitivity results of the parameters for ADPe impact category: BL (left) and NL (Right) The results show that three parameters, namely, the CB area, number of LEDs and trunking weight are the main contributors in the BL, whereas, CB area, capacitors and wire are the main contributors in the case of the NL, therefore, a variation of their values can influence the results. The range of uncertainty for the ADPe, calculated using the Monte Carlo analysis is shown in Figure 9. The uncertainty analysis was performed with a 95% confidence interval. The distribution of values for the ADPe has been performed varying the parameters identified in the sensitivity analysis. This variation can be considered as a possible natural variation of the parameters considering that the luminaire keeps its performance. Figure 9 ADPe for both luminaires (mean values along with standard deviation in the form of 95% confidence interval) As shown in Figure 11, the values for the ADPe category can be placed, with 95% confidence, in a range between ±10% and ±9% for the BL and NL, respectively. For the BL, Coefficient of Variation (CV) is 10%. This percentage or the CV, which is the relative ratio of the standard deviation to the mean, is higher when compared with that of the NL which is 9% of the its mean value of 0.309kg Sb eq. The higher CV’s are normally a result of a combination of two -15.00% -10.00% -5.00% 0.00% 5.00% 10.00% 15.00% factors: the high incidence of the selected risk parameters in these impact categories and the mean value of the impact, which is very close to zero (Escobar et al., 2014). As can be seen from Figure 9, the uncertainty is in any way relevant in the comparative assessment of the two luminaires, because even with the high CV’s, the variation around the mean is not substantial. These uncertainty ranges are not as wide-ranging, and hence the Monte Carlo simulation showed that a ±10% change in parameters could not reverse the comparative results obtained for the two luminaires. Electricity mix scenarios sensitivity study The results have shown that the use is the stage having a significant environmental burden in the life cycle of the LED luminaire, which is associated with the resources used to produce the energy (electricity consumption). This means that the electricity mix of the country where the LED luminaire is implemented plays an important role in its environmental performance. Therefore, the influence of the energy source on the impact categories for a lighting system constituted by NL is studied in this section. To do this, differentiated electricity mix grids of 4 countries (Sweden, France, Spain and Italy) were chosen. All of them were taken from GaBi dataset which documentation states an electricity mix dated in 2015, which are used to discuss the environmental behaviour of the luminaire in the use phase when varying the type of energy source. Overall environmental results in terms of percentage to compare the different electricity mix scenarios are shown in Figure 10. The E28 electricity mix grid scenario is used as a reference to 100%. Figure 10 Percentage contribution of the overall environmental performance for the NL comparing different electricity generation sources It can be seen that the results depend of the impact categories analysed. The Sweden and France scenarios show lower impact in all categories respect to the E28 scenario used in the study, being the Sweden scenario with the lowest impact in ADPf, AP, EP and GWP ranging from 6 to 23%. This is attributed mainly to the characteristics of the Sweden electricity mix with low fossil fuel source. The ADP element of the Sweden is also lower than E28 scenario, but still with a high impact of 80% respect to the rest scenarios, that is attributed to the use of higher non-renewable elements, such as antimony, chromium, copper and gold used in the upstream process. France scenario also exhibit 84% in the ADP element because the use of uranium characterized as a non-renewable energy resource and because of the non-renewable elements as the ones mentioned in the Sweden scenario. In addition, both Sweden and France scenarios 0 20 40 60 80 100 120 ADPe ADPf AP EP GWP PE (%) Sweden France Spain Italy E28 have considerable impact in the PE category due to the use of Uranium (non-renewable energy resource) and hydropower, solar and wind power categorized as renewable energy resources. In contrast, Italy and Spain scenarios are similar to the E28 electricity mix grid scenario in the AP, GWP, EP and PE categories. Italy scenario is higher in ADP element and ADP fossil (around 124%) because the use of non-renewable element resources (antimony, chromium, copper, etc.) and natural gas as a non-renewable energy resource, which also makes the GWP and PE slightly higher (105 and 103%, respectively) due to the natural gas and hard coal. In conclusion, the source of energy influences in the environmental performance of the luminaire. The use of an electricity mix similar to the Sweden with higher contribution of renewable energy source bring an important impact reduction in the categories ADPf, AP, EP and GWP of the Luminaire. However, this electricity mix is not free of other type of nonrenewable energy source, such as the nuclear energy (Uranium) besides the use of nonrenewable elements, which contribute directly on the ADPe and PE categories. 4 Scenarios to change the LED modular luminaire life cycle towards more sustainability As mentioned above, the LEDM is considered as a potential component for modularity. This could cogitate allowance for replacement of the parts as opposed to disposal of the entire luminaire, leading to reductions in waste generation as well as material use by keeping parts of the luminaire in use for longer. However, this should be investigated using scenarios for exchangeable LEDM in order to know if this characteristic brings more sustainability to the luminaires. In addition, other scenarios taking into account the optimal material efficiency and optimal energy efficiency as a function of time should be also studied to know if the replacement of the entire luminaire brings environmental benefits considering both efficiencies. These scenarios are developed in the next sections. 4.1 Optimal LED Luminaire usage times in terms of energy and material efficiency The lifetime of an LED based luminaire is not unambiguous to define, since the LEDs do not fail abruptly (like fluorescent or incandescent lamps in earlier times), but gradually. The luminous flux of an LED decreases over time, a phenomenon called degradation. This degradation is typically modelled by an exponential law as described in Eq((3). 𝜙(𝑡)=𝜙0⋅𝑒−𝛼 𝑡 (3) where 𝜙0 is the initial luminous flux at time 𝑡=0 and 𝛼 is the degradation rate. The degradation rate is highly temperature-dependent according to the Arrhenius law. In this study, it is assumed that the operating temperature of the LED is constant, thereby that temperature dependence is not taken into account. Typically, the end of the useful lifetime of an LED product is defined as the time at which the luminous flux has dropped to 80% of the initial value and denoted as 𝐿80 lifetime (in hours)(ANSI/IES TM-21-19, 2019; LightingEurope, 2018). More generally, the lifetime 𝐿𝑥 is defined as the time at which the luminous flux has dropped to 𝑥% of the initial value, which results in the Eq((4). 𝐿𝑥=−ln(𝑥 100) 𝛼 (4) It is important to note that the value 𝑥 to determine the lifetime 𝐿𝑥 is a choice and not given by LED nature (LightingEurope, 2018). The BL is specified with a lifetime of 𝐿80 =70,000 h, corresponding to a degradation rate of 𝛼=3.19⋅10−6 h−1. The lifetime definitions 𝐿70 = 112,000 h or 𝐿90 =33,000 h are both completely equivalent to the original lifetime specification 𝐿80 =70,000 h, provided that the other components of the luminaire also have long enough lifetime. Thus, there is a certain degree of freedom to decide how long a luminaire shall be used. If used for short times (like 33,000 h), it will have a small degradation; when used longer (like 112,000 h), the degradation will increase. We did not consider the influence that luminaires may be switched on and off more often in some applications than in others. For LED based technology, the switching is not as problematic as it was for conventional lighting. For our model calculations, this means that it is irrelevant if the operating times are reached in a continuous operation, or if they are switched off in between. In order to determine the optimal lifetime (or rather usage time), a simple model for the overall energy efficiency and material efficiency of a luminaire is developed and optimised with respect to the usage time. In general, the efficiency of a system is defined as the useful output divided by the necessary input. For a luminaire, it could be assumed that the useful output is the light being generated, or more precisely the luminous energy 𝑄(𝑡) that has been produced up to time 𝑡. It is obtained by integrating the luminous flux over time as shown in Eq((5). 𝑄(𝑡)=∫ 𝜙(𝑡′) d𝑡′ 𝑡 0=𝜙0 𝛼⋅(1−𝑒−𝛼 𝑡). (5) From this, it can be concluded that the maximum luminous energy extracted from an LED is finite as indicated in Eq((6). 𝑄∞= lim 𝑡→∞𝑄(𝑡)=𝜙0 𝛼 (6) From the above equations, it is apparent that after the lifetime 𝐿80, when the luminous flux has dropped to 80% of the initial value, only 20% of the total extractable luminous energy has been extracted from the LED. In other words, today, LEDs are usually thrown away when they are “used up” to 20%. Therefore, in order to achieve a minimal usage of raw materials, it would thus be adequate to search for possibilities to extract as much luminous energy as possible from the LEDs. In this study, the inputs to the efficiency calculation are assumed to be the consumed resources, measured by the ADPe metric for the “material efficiency” and measured by the PE metric for the “energy efficiency”. Note that these definitions of material and energy efficiency cannot be strictly separated: The ADPe metric also contains contributions from the use phase (ADPe needed to generate the electricity that is consumed by the luminaire). On the other hand, the PED metric also contains contributions from the material mining and processing. Despite these observations, we still consider it useful to use the names of material and energy efficiency in the discussions. Both consumptions can be modelled with a linear function in time, reflecting contributions of the production (𝐴𝐷𝑃0, 𝑃𝐸𝐷0) and use phase, as shown in Eq((7) and Eq((8). 𝐴𝐷𝑃(𝑡)=𝐴𝐷𝑃0+𝑚𝐴𝐷𝑃 ⋅𝑃𝐵⋅𝑡; with 𝑚𝐴𝐷𝑃 =1.327⋅10−7 kg Sb-eq/kWh (7) 𝑃𝐸𝐷(𝑡)=𝑃𝐸𝐷0+𝑚𝑃𝐸𝐷 ⋅𝑃𝐵⋅𝑡; with 𝑚𝐴𝐷𝑃 =10.552 MJ/kWh (8) where 𝑃𝐵 is the electrical power of the luminaire, and 𝑚𝐴𝐷𝑃 and 𝑚𝑃𝐸𝐷 are two factors quantifying how much of ADP elements and how much of PE is needed for the generation of 1 kWh of electricity in the current EU-28 grid mix (Table 6). This leads to a material efficiency and energy efficiency defined as Eq(9) and Eq(10), respectively. (9) (10) Both efficiencies have a maximum, but at different points in time. Figure 11 shows a plot of both functions of Eq(9) and Eq(10), scaled to a maximum value of 1, and the parameters have been set to the LCA results of the BL with lifetime 𝐿80 =70.000 h. At time 𝑡=0, both efficiencies start at 𝜂𝑃𝐸𝐷 =𝜂𝐴𝐷𝑃 =0, i.e., no light has been generated so far, thereby the useful output is zero. However, there are initial environmental burdens for the production of the luminaire. The optimum in energy efficiency is reached at 𝑡=18,000 h of operating time. From then on, the energy efficiency slowly decreases, while the material efficiency still increases. The maximum in material efficiency is reached at 𝑡=295,000 h. All points in between are called Pareto-optimal (one characteristic cannot be improved without making the other one worse). Figure 11 Time evolution of the total energy efficiency (blue) and material efficiency (orange) according to equation (6) for the BL. The reason why the maximum energy efficiency is reached quite early, after only 18,000 hours of use, is because the contribution of the luminaire production to the PE is very low as shown in Figure 5. In this scenario of optimal energy efficiency, the complete luminaire should be 0 0.2 0.4 0.6 0.8 1 0 100 000 200 000 300 000 400 000 scaled efficiency operating time, h hPED hADP 𝜂𝑃𝐸𝐷 𝜂𝐴𝐷𝑃 𝜂𝐴𝐷𝑃(𝑡)=𝑄∞⋅ 1−exp(−𝛼 𝑡) 𝐴𝐷𝑃0+𝑚𝐴𝐷𝑃 ⋅𝑃𝐵⋅𝑡 𝜂𝑃𝐸𝐷(𝑡)=𝑄∞⋅ 1−exp(−𝛼 𝑡) 𝑃𝐸𝐷0+𝑚𝑃𝐸𝐷 ⋅𝑃𝐵⋅𝑡 stage as a result of reducing the printed CB area and its quantity in the LEDM, besides avoiding precious metals as gold in the LEDs. The sensitivity study for the electricity mix scenarios showed that the source of energy substantially influences the environmental performance of the luminaires. Therefore, it must be noted that if renewable energy is used, the production stage will have probably higher relevance instead of the use phase which is the most dominant one presently. Hence, making the efforts to improve the sustainability should be focused on this stage as well. Scenarios for a more sustainable LED modular luminaire life cycle Due to the significant environmental contribution in the depletion of non-renewable mineral reserves, the replacement of the LEDM as a component is usually expected to be favourable as opposed to disposal of the entire luminaire. Thereby the environmental impact of the NL considering the LEDM serviceable characteristic was analysed. In contrast to the expectations, different scenarios for the exchangeability of this component revealed that environmental benefit is not always achieved and that it depends on the category of impact that is considered to be of greatest importance. The main remarks of these scenarios are set out as follows: (i) Exchangeable LEDMs for maintenance scenario, which considers to restore the energy efficiency, shows that for one exchange of LEDM the environmental burdens in ADPe category associated with the exchangeable parts are almost doubled for one exchange. This behaviour continues for two and three exchanges of LEDM increasing even more the production related environmental burden due to the additional manufacturing of LEDMs needed for replacement. Meanwhile, the environmental burdens associated with the energy (PE) are decreased in the use phase (around 10%). Therefore, this scenario leads to a drawback by generating more LEDM waste than necessary, affecting the ADPe category, which makes offsetting in the PE category via energy savings less appealing. An alternative approach is the use of CLO technology as potential recommended eco-design strategy, which would avoid additional material for LEDM replacements and resolve the maintenance factor and over illumination issues. (ii) The exchangeable LEDMs scenario for repair purposes, shows that the option with exchangeable LEDM causes an additional impact on the total ADPe, around 0.15%, which is attributed to the production of connectors for exchangeable LEDMs for the 369 luminaires in the industrial setting. Nevertheless, a benefit of -31% is observed for the spare part stage since only LEDM would be needed to be replaced instead of one entire luminaire. However, the stage of spare parts has a very low impact in the overall life cycle of the luminaire, providing very trivial benefits. It can be said that rather a negative effect is observed in this scenario. In addition to the above scenarios, exchangeable components for repair and for maintenance, further research is needed on the actual reasons a luminaire (or components) are required to be replaced in various applications. Comparing the luminaire lifetime to the typical refurbishment cycles (LightingEurope, 2018) shows that the technical lifetime of the product is not always the limiting factor for the actual usage time. Only when it is known why the LED luminaires will be disposed-off (in 10 to 25 years from now on), design improvements, delivering true benefits for the sustainability of lighting systems can be developed. (iii) Regarding the scenario intended for the possibility to exchange the entire luminaire gear tray (with integrated LEDM, LEDC and optics) according to its optimal use, from the material and energy efficiency viewpoint, reveals two optimal usage times. Neither of them is preferred since material and energy are two different fundamental resources. As today’s LED luminaires for industry applications typically have lifetimes between 50,000 hours and 100,000 hours, those lifetimes are in between the points of maximum energy efficiency and maximum material efficiency. This design choice can be labelled as a boon or bane for the environment depending on how the energy is valued in contrast to the material. However, there is a future scenario where only one relevant efficiency remains, rendering the unique optimal usage time. This is when the electricity is completely generated from renewable sources, so the consumption of materials that are limited on earth remains the only focal point of concern. It is thus urgently required that the lighting industry broadens its sustainability scope from a pure energy-efficiency argumentation, that is dominant in the market today, towards a scope considering material and energy usage in parallel. Nomenclature Acknowledgments This work was supported by the research and innovation programme Horizon 2020 of the European Union under the Grant Agreement ID 768780 (Repro-light). References Ambilamp, 2020. Recylcamos la luz [WWW Document]. URL https://www.ambilamp.es/en/corporate-information ANSI/IES TM-21-19, 2019. Technical Memorandum: Projecting Long Term Lumen, Photon, and Radiant Flux Maintenance of LED Light Sources. Illuminating Engineering Society. Apisitpuvakul, W., Piumsomboon, P., Watts, D.J., Koetsinchai, W., 2008. LCA of spent fluorescent lamps in Thailand at various rates of recycling. J. Clean. Prod. 16, 1046– 1061. https://doi.org/https://doi.org/10.1016/j.jclepro.2007.06.015 Baker, J.W., Lepech, M., 2009. Treatment of uncertainties in life cycle assessment, in: 10th International Conference on Structural Safety and Reliability ICOSS. Osaka, Japan. Bare, J.C., Hofstetter, P., Pennington, D.W., de Haes, H.A.U., 2000. Midpoints versus endpoints: The sacrifices and benefits. Int. J. Life Cycle Assess. 5, 319. https://doi.org/10.1007/BF02978665 Birloaga, I., De Michelis, I., Ferella, F., Buzatu, M., Vegliò, F., 2013. Study on the influence of various factors in the hydrometallurgical processing of waste printed circuit boards ABS Acrylonitrile butadiene styrene ADPe Abiotic Depletion Potential elements ADPf Abiotic Depletion Potential fossil AP Acidification Potential CB Circuit Board CFL Compact Fluorescent Lamps CLO Constant Light Output ECG Electronic Control Gear EoL End of Life EP Eutrophication Potential EU European Union GWP Global Warming Potential LCA Life cycle Assessment LCI Life Cycle Inventory LCIA Life Cycle Impact Assessment LED Light-Emitting Diode LEDC Light-Emitting Diode Control LEDM Light-Emitting Diode Module PE Primary Energy Demand PET Polyethylene Terephthalate PMMA Polymethyl Methacrylate PP Polypropylene REE Rare Earth Elements RoHS Restriction of Hazardous Substances SMD Surface Mounted Device WEEE Waste Electrical and Electronic Equipment for copper and gold recovery. Waste Manag. 33, 935–941. https://doi.org/https://doi.org/10.1016/j.wasman.2013.01.003 Casamayor, J.L., Su, D., 2020. Assessment of the Environmental Impact of Lighting Product BT - Sustainable Product Development: Tools, Methods and Examples, in: Su, D. (Ed.), . Springer International Publishing, Cham, pp. 271–291. https://doi.org/10.1007/978-3- 030-39149-2_13 Casamayor, J.L., Su, D., Ren, Z., 2017. Comparative life cycle assessment of LED lighting products. Light. Res. Technol. 50, 801–826. https://doi.org/10.1177/1477153517708597 Cellura, M., Longo, S., Mistretta, M., 2011. Sensitivity analysis to quantify uncertainty in Life Cycle Assessment: The case study of an Italian tile. Renew. Sustain. Energy Rev. 15, 4697–4705. https://doi.org/https://doi.org/10.1016/j.rser.2011.07.082 Clarke-Sather, A., Li, Y., Qu, J., 2016. Lighting energy use in Anding District, Gansu Province, China. Energy Sustain. Dev. 32, 40–49. https://doi.org/https://doi.org/10.1016/j.esd.2016.02.012 Commission Regulation (EC) No 244/2009, 2009. implementating Directive 2005/32/EC with regard to ecodesing requiremens for non-directional house-hold lamps. Ofcial J. o EU L76, 2–16. DIALux, 2020. Ligthing design Software [WWW Document]. URL https://www.dialux.com/en-GB/dialux Directive 2009/125/EC, 2009. of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energyrelated products. Off. J. Eur. Union L285, 10–35. Directive 2011/65/EU, 2011. of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. Off. J. Eur. Union L174, 88–110. Dzombak, R.., 2017. Harmonizing Technological Innovation and End-of-Life Strategy in the Lighting Industry. University of California. Elijošiutė, E., Balciukevičiūtė, J., Denafas, G., 2012. Life Cycle Assessment of Compact Fluorescent and Incandescent Lamps: Comparative Analysis. Environ. Res. Eng. Manag. 61. https://doi.org/10.5755/j01.erem.61.3.2425 Escobar, N., Ribal, J., Clemente, G., Sanjuán, N., 2014. Consequential LCA of two alternative systems for biodiesel consumption in Spain, considering uncertainty. J. Clean. Prod. 79, 61–73. https://doi.org/https://doi.org/10.1016/j.jclepro.2014.05.065 European Commission, 2018. Directive 2012/19/EU of the European Parlamanet and of the Council of 4 July 2012 on waste electrical and electronic equipment (WEEE). Off. J. Eur. Union L 150, 93. European Commission, 2009. Directive 2009/125/EC of the European Parliament and of the Council. Off. J. Eur. Union L 285, 10–35. Eurostat, 2019. Summary document of the Waste electrical and electronic equipment rates and targets. Fashola, M.O., Ngole-Jeme, V.M., Babalola, O.O., 2016. Heavy Metal Pollution from Gold Mines: Environmental Effects and Bacterial Strategies for Resistance. Int. J. Environ. Res. Public Health 13. https://doi.org/10.3390/ijerph13111047 Ferreira, V., Wolff, D., Corchero, C., 2019. On Life Assessment to quantify the Environmental Impact of Lighting Products. LED Prof. Rev. Geert Bergsma, M.S., 2013. End-of-life best approach for allocating recycling benefits in LCAs of metal packaging. Guinée, J.B., – M.G., Heijungs, R., Huppes, G., Kleijn, R., de Koning, A., van Oers, L., Sleeswijk, A.W., Suh, S., de Haes, H.A.U., 2002. Handbook on Life Cycle Assessment, 1st ed. Springer Netherlands. https://doi.org/10.1007/0-306-48055-7 Haupt, M., Zschokke, M., 2017. How can LCA support the circular economy?—63rd discussion forum on life cycle assessment, Zurich, Switzerland, November 30, 2016. Int. J. Life Cycle Assess. 22, 832–837. https://doi.org/10.1007/s11367-017-1267-1 Industrial Safety & Higiene News SHV, 2016. Lumen Recommendations for Common and Industrial Work Spaces. Irsyad, M.I. al, Nepal, R., 2016. A survey based approach to estimating the benefits of energy efficiency improvements in street lighting systems in Indonesia. Renew. Sustain. Energy Rev. 58, 1569–1577. https://doi.org/https://doi.org/10.1016/j.rser.2015.12.294 ISO-14040, 2006. Environmental management - Life cycle assessment - Principles and framework. ISO-14044, 2006. Environmental management - Life cycle assessment - Requirements and guidelines. Knoche, S., 2019. Data analytics in connected lighting systems – a case study. LpS 2019. Kupfer, T., Baitz, M., Colodel, C.M., Kokborg, M., Schöll, S., Rudolf, M., Bos, U., Bosch, F., Gonzalez, M., Schuller, O., Hengstler, J., Stoffregen, A., Thylmann, D., 2020. GaBi Databases & Modeling Principles 2020. Liang, G., Tang, J., Liu, W., Zhou, Q., 2013. Optimizing mixed culture of two acidophiles to improve copper recovery from printed circuit boards (PCBs). J. Hazard. Mater. 250– 251, 238–245. https://doi.org/https://doi.org/10.1016/j.jhazmat.2013.01.077 LightingEurope, 2018. Evaluating performance of LED based luminaire. LightingEurope, 2017. ‘White Paper - Serviceable Luminaires in a Circular Economy’’.’ LigthingEurope, 2015. Voice of the Lighting Industry in Europe. Liu, L., Keoleian, G.A., 2020. LCA of rare earth and critical metal recovery and replacement decisions for commercial lighting waste management. Resour. Conserv. Recycl. 159, 104846. https://doi.org/https://doi.org/10.1016/j.resconrec.2020.104846 Long, L., Sun, S., Zhong, S., Dai, W., Liu, J., Song, W., 2010. Using vacuum pyrolysis and mechanical processing for recycling waste printed circuit boards. J. Hazard. Mater. 177, 626–632. https://doi.org/https://doi.org/10.1016/j.jhazmat.2009.12.078 Lozano-Miralles, J.A., Hermoso-Orzáez, M.J., Gago-Calderón, A., Brito, P., 2020. LCA Case Study to LED Outdoor Luminaries as a Circular Economy Solution to Local Scale. Sustain. 2020 12, 190. Mizanur Rahman, S.M., Kim, J., Lerondel, G., Bouzidi, Y., Nomenyo, K., Clerget, L., 2017. Missing research focus in end-of-life management of light-emitting diode (LED) lamps. Resour. Conserv. Recycl. 127, 256–258. https://doi.org/https://doi.org/10.1016/j.resconrec.2017.04.013 Morgan Pattison, P., Hansen, M., Tsao, J.Y., 2018. LED lighting efficacy: Status and directions. Comptes Rendus Phys. 19, 134–145. https://doi.org/https://doi.org/10.1016/j.crhy.2017.10.013 Navajas, A., Uriarte, L., Gandía, L.M., 2017. Application of Eco-Design and Life Cycle Assessment Standards for Environmental Impact Reduction of an Industrial Product. Sustainability 9, 1724. Next Generation Lighting Industry Alliance, Consortium, L.S.R., 2014. LED LUMINAIRE LIFETIME: RECOMMENDATIONS FOR TESTING AND REPORTING. Official Journal of the European Union, 2019. COMMISSION REGULATION (EU) 2019/2020 of 1 October 2019 laying down ecodesign requirements for light sources and separate control gears pursuant to Directive 2009/125/EC of the European Parliament and of the Council and repealing Commission Regulations (EC L315, 209–240. Principi, P., Fioretti, R., 2014. A comparative life cycle assessment of luminaires for general lighting for the office – compact fluorescent (CFL) vs Light Emitting Diode (LED) – a case study. J. Clean. Prod. 83, 96–107. https://doi.org/https://doi.org/10.1016/j.jclepro.2014.07.031 Priya, A., Hait, S., 2017. Comparative assessment of metallurgical recovery of metals from electronic waste with special emphasis on bioleaching. Environ. Sci. Pollut. Res. 24, 6989–7008. https://doi.org/10.1007/s11356-016-8313-6 Rahman, S.M.M., Kim, J., Lerondel, G., Bouzidi, Y., Clerget, L., 2019. Value Retention Options in Circular Economy: Issues and Challenges of LED Lamp Preprocessing. Sustain. . https://doi.org/10.3390/su11174723 Rio, M., Reyes, T., Lionel, R., 2010. A framework for eco-design: An interface between LCA and design process. Int. J. Eng. 9. Shahzad, K., Čuček, L., Sagir, M., Nizami, D.A.-S., Iqbal, T., Almeelbi, T., I.M.I., I., 2016. A Case Study for Developing Eco-efficient Street Lighting System in Saudi Arabia. Chem. Eng. Trans. 52, 1141–1146. https://doi.org/10.3303/CET1652191 Sphera-GaBi solutions, 2020. Description of the CML 2001 Method [WWW Document]. Sphera, Solutions, G., 2020. GaBi ts 9.2.1. Stocker, T.F., D. Qin, G.-K.P., M. Tignor, S.K.A., Boschung, J., Nauels, A., Xia, Y., Bex, V., Midgley, P.M., 2013. IPCC, 2013: Climate Change 2013: The Physical Science Basis. Cambridge University Press, Cambridge, United Kingdom and New York, NY, USA,. Szita, K., 2017. THE APPLICATION OF LIFE CYCLE ASSESSMENT IN CIRCULAR ECONOMY. Hungarian Agric. Eng. 5–9. https://doi.org/10.17676/HAE.2017.31.5 Tähkämö, L., Bazzana, M., Ravel, P., Grannec, F., Martinsons, C., Zissis, G., 2013. Life cycle assessment of light-emitting diode downlight luminaire---a case study. Int. J. Life Cycle Assess. 18, 1009–1018. https://doi.org/10.1007/s11367-012-0542-4 Tähkämö, L., Bazzana, M., Zissis, G., Puolakka, M., Halonen, L., 2014. Life cycle assessment of a fluorescent lamp luminaire used in industry – a case study. Light. Res. Technol. 46, 453–464. Tähkämö, L., Dillon, H., 2017. Life Cycle Assessment of Lighting Technologies, in: Karlicek, R., Sun, C.-C., Zissis, G., Ma, R. (Eds.), Handbook of Advanced Lighting Technology. Springer International Publishing, Cham, pp. 935–956. https://doi.org/10.1007/978-3-319-00176-0_41 Tähkämö, L., Puolakka, M., Halonen, L., Zissis, G., 2012. Comparison of Life Cycle Assessments of LED Light Sources. J. Light Vis. Environ. 36, 44–54. https://doi.org/10.2150/jlve.36.44 Tetri, E., Sarvaranta, A., Syri, S., 2014. Potential of new lighting technologies in reducing household lighting energy use and CO2 emissions in Finland. Energy Effic. 7, 559–570. https://doi.org/10.1007/s12053-013-9240-8 Thavornvong W, 2016. Life Cycle Assessment of Lighting Equipment: A Comparison of Fluorescent Lamp and Light Emitting Diode Lamp in Thailand. Chulalongkorn University. Thinkstep, 2015. GaBi Databases. US DOE. US Department of Energy., 2009. LED Measurement Series: LED Luminaire Reliability [WWW Document]. URL https://cool.culturalheritage.org/byorg/usdoe/luminaire_reliability.pdf Van Oers, L., Koning A, D., Guinée, J., Huppes, G., 2002. Abiotic resource depletion in LCA. Worldsteel Association, 2017. LIFE CYCLE INVENTORY METHODOLOGY REPORT. Zhang, H., Burr, J., Zhao, F., 2017. A comparative life cycle assessment (LCA) of lighting technologies for greenhouse crop production. J. Clean. Prod. 140, 705–713. https://doi.org/https://doi.org/10.1016/j.jclepro.2016.01.014