Defining parameters of ventilated façades and their influence on the energy performance of the system
Full text
Autor: Oriol Roig Mayoral Directora: Dra. Cristina Pardal March Codirectors: Dr. Antonio Isalgue Buxeda Dr. Ignacio Paricio Ansuategui Amb el suport de la Secretaria d’Universitats i Recerca de la Generalitat de Catalunya i del Fons Social Europeu Figure 4. Inuence of the channel dimensions on two different cases: Omega UPC 21/06/2019 (left), Química UAB 10/07/2022 (right). Figure 3. Example of the validation graphs for one of the cases; inner temperature of the cladding, Omega UPC 21/06/2019. Figure 2. Measured and calculated temperatures in one of the studied cases: Omega UPC, 21/06/2019. Figure 1. Energy and material ows in the ventilated façade. In the current climate emergency, any strategy or system that can reduce environmental impacts must be assessed. Improving the thermal performance of the envelope can signicantly reduce the energy demand of buildings. Ventilated façades can make progress in this direction by avoiding the overheating of sunny enclosures, thereby reducing the cooling demand. 1. Objective Architects lack the tools to know how design decisions (cavity width, joint height, outer sheet material, etc.) inuence the energy performance of ventilated façades. These characteristics are not considered in the usual calculation systems and can be relevant to the energy performance of the envelope. The aim of this work is to develop a method for estimating that inuence. 2. Methodology An algorithm considering the dening parameters is developed and validated with data taken from real buildings. Once validated and applied, it can provide design guidelines for ventilated façades. 3. Energy performance TThere are four energy ows involved in energy performance: shortwave solar radiation, longwave infrared radiation, conduction, and convection. Additionally, material ow must be considered: air entering through the joints and moving along the cavity under the inuence of the stack effect and wind pressure. Any parameter affecting any of these ows will affect the overall performance (Figure 1). 4. Algorithm development The transient algorithm calculates the ows and the evolution of temperature on each surface; it also calculates the air circulation through the cavity and the openings. Once the whole daily cycle is complete, the algorithm displays the desired data, which can be used to draw conclusions. 5. Data measurement and algorithm validation The study of the air movement in the cavity is not for the movement itself, but rather its energy effect. To validate the algorithm, we need data over several days, from different points of the façade. Temperatures are measured with NTC 100K 3950 sensors, without signicantly affecting the performance of the measured facade (Figure 2). TThe calculation system can be validated by comparing measured and calculated temperatures. For the ve measured façades, most days have R² values higher than 0.9 for surface temperatures (Figure 3). 6. Application of the algorithm on the parameter inuence OnOnce validated, the system can be applied to analyse the inuence of different parameters of the façade. To do so, the energy performance of the façade is calculated with different values within the dened limits of the studied parameter. TThe attached graphs present the inuence of the variation of the dimensions of the ventilation channel for two of the measured buildings. As can be seen, the change in these parameters can imply an important variation in the daily average energy ow through the façade (Figure 4). 7. Conclusions TThe results obtained show that the proposed algorithm, once validated, can provide guidelines for the energetic design of the ventilated facade. With this, architects would be able to adapt the ventilated façade to each situation, to improve its energy performance, and thus reduce the energy demand of the building. DEFINING PARAMETERS OF VENTILATED FAÇADES AND THEIR INFLUENCE ON THE ENERGY PERFORMANCE OF THE SYSTEM