Full text
i Ph.D. Program in Civil, Chemical and Environmental Engineering Department of Civil, Chemical and Environmental Engineering Polytechnic School, University of Genoa Ph.D. Program in Construction Engineering Department of Civil and Environmental Engineering Technical University of Catalonia Structural Behaviour of Masonry Arches on Moving Supports: from On-site Observation to Experimental and Numerical Analysis Chiara Ferrero
ii
iii S TRUCTURAL B EHAVIOUR OF M ASONRY A RCHES ON M OVING S UPPORTS : FROM O N - SITE O BSERVATION TO E XPERIMENTAL AND N UMERICAL A NALYSIS B Y C HIARA F ERRERO Dissertation discussed in partial fulfilment of the requirements for the Degree of DOCTOR OF PHILOSOPHY Civil, Chemical and Environmental Engineering University of Genoa, Genoa, Italy Construction Engineering Technical University of Catalonia, Barcelona, Spain June, 2021
iv Thesis Supervisors Prof. Chiara Calderini – University of Genoa, Italy Prof. Pere Roca – Technical University of Catalonia, Spain External Reviewers: Prof. Vasilis Sarhosis – University of Leeds, United Kingdom Prof. Els Verstrynge – KU Leuven, Belgium Examination Committee: Prof. Katalin Bagi – Budapest University of Technology and Economics, Hungary Prof. Katrin Beyer – École Polytechnique Fédérale de Lausanne, Switzerland Prof. Matthew J. DeJong – University of California, Berkeley, USA Cotutelle agreement: University of Genoa Ph.D. program in Civil, Chemical and Environmental Engineering (Doctor Europaeus Mention) Structural and Geotechnical Engineering, Mechanics and Materials Cycle XXXIII Technical University of Catalonia Ph.D. program in Construction Engineering (International Ph.D. Mention)
v ACKNOWLEDGMENTS First of all, I want to thank my supervisors for guiding my research. I would like to express my gratitude to Prof. Chiara Calderini for involving me in such an interesting research and trusting me since the first moment. I am indebted to Prof. Roca for welcoming me in his research group in Barcelona and for sharing with me his knowledge on masonry structures. Furthermore, I want to thank him for his encouragement and valuable meetings not only during the last three and a half years, but especially during last months. Without his support, I would not have completed my thesis on time. I would like to acknowledge the Italian Ministry of Education, University and Research (MIUR) for financing the Ph.D. grant at the University of Genoa. This work has also benefited from additional financial support from the Italian Ministry of Education, University and Research (MIUR) through the PRIN 2015 Program “Protecting the Cultural Heritage from water-soil interaction related threats” (Prot. No. 2015EAM9S5). I gratefully acknowledge Prof. Francesco Portioli (University of Naples Federico II) for giving me the opportunity to use the results from his numerical model for enriching my thesis and for the fruitful discussions about numerical modelling. I want to thank Giuseppe Tarantino, Davide Burlando and the personnel of Structural Engineering Laboratory of the University of Genoa for all the help that they have given me with the preparation of the experimental campaign. Prof. Luigi Carassale and Prof. Enrico Lertora are also gratefully acknowledged for their help with the data acquisition and preparation of the physical model, respectively. I am grateful to all my friends and colleagues in Genova and Barcelona for their interest in my work and the nice time we had together. A special thanks goes to Ludovica for her support and all the laughs we shared, Antonetta for always being available and happy to help, and Larisa and Nirvan for their encouragement during the last weeks of work. I also want to thank my Canadians friends, Kristen and Krista, for their help with the English writing. I want to express my deepest gratitude to Jorge for being my reference point in Barcelona, for his friendship, valuable advice, and continuous support from the very beginning to the end of this adventure. Thank you for all the time you devoted to helping me in the post-processing of the experimental data, to revising many times the same sentences and to listening to all my complaints. I owe my deepest gratitude to my family. I am grateful for their unconditional love, patience and for supporting every choice I made in my life, even if it took me away from home. Finally, a special thanks goes to Edoardo. I am indebted to him for his support and love, for driving me to Genova during the weekends to finish the experimental tests in the middle of a pandemic, for helping me in preparing the annexes, for reading my work, for accepting to be so many months apart. Without you, this thesis would have never been completed. Grazie.
vi This page is intentionally left blank.
vii ABSTRACT Since ancient times, master builders have used arches to cover large spans in masonry structures. As a consequence, nowadays the safety assessment of these structural elements plays a fundamental role in the conservation of built cultural heritage. Due to their frequent occurrence, support displacements are one of the primary sources of damage for masonry arches. Among the potential causes of support displacements, slow-moving landslides have received very little attention from the scientific community. The present thesis is motivated by the observation of extensive and severe damage in the arches of historic masonry churches exposed to slowmoving landslides. These phenomena produce a combination of vertical and horizontal supports displacements, whose effect on the arch structural behaviour has never been thoroughly investigated in the literature, especially in the framework of large displacements. In view of the above, this thesis aims at providing a full understanding of the mechanics of masonry arches subjected to large support displacements, with special attention to inclined displacements. The methodology used to accomplish this goal included both experimental tests and numerical analyses on a segmental scaled dry-joint masonry arch subjected to different combinations of horizontal and vertical displacements at one support. The numerical simulations were carried out in the framework of large displacements using two different numerical approaches based on finite element (FE) and rigid block (RB) modelling. A micro-modelling strategy was adopted, where the arch was modelled as an assemblage of voussoirs, very stiff and infinitely resistant in compression in the FE model and rigid in the RB model, interacting at no-tension friction interfaces. Preliminary numerical simulations, aimed at designing the experimental set-up and gaining a first insight in the arch response, were carried out considering the arch as a rigid-no tension structure. To this aim, a very large value of interface normal stiffness was adopted in the FE model. A large experimental campaign was performed on a 1:10 small-scale model built as a dry-joint assemblage of voussoirs made of a bicomponent composite material. The results of the tests allowed, for the first time in the literature, to accurately assess the effect of the direction of the imposed support displacements on the arch response in the framework of large displacements. The comparison between numerical and experimental results showed that the numerical models were not able to accurately predict the experimental response, especially in terms of ultimate displacement capacity. To investigate this discrepancy, a sensitivity analysis on the effect of the interface normal stiffness on the FE predictions was performed. The results demonstrated that the difference between numerical and experimental results could be attributed due to the imperfections, and resulting deformability, of the joints of the physical model. A strategy to include imperfections in the numerical modelling, consisting in calibrating the interface normal stiffness based on the experimental results, was thus proposed and validated by performing further FE simulations, whose results were in very good agreement with the experimental evidence. Finally, to investigate the effect of geometrical imperfections on the arch response, a further experimental test was performed on a physical model made of bicomponent composite voussoirs exhibiting more imperfections. The test was simulated using a FE calibrated model to further validate the strategy proposed
viii ABSTRACT viii to model imperfections. The comparison between the experimental results for the two tested physical models showed that imperfections play a fundamental role in the response of small-scale arches to large support displacements. Furthermore, reducing the interface normal stiffness with respect to the large value adopted to model rigid interfaces proved to be an effective strategy to simulate the amount of imperfections of the experimental models. Keywords: dry-joint masonry arches; inclined support displacements; finite element modelling; rigid block modelling; experimental testing; geometrical imperfections.
ix SOMMARIO Fin dall’antichità, i maestri costruttori hanno utilizzato gli archi per coprire grandi luci nelle strutture in muratura. Di conseguenza, ad oggi la valutazione della sicurezza di questi elementi strutturali gioca un ruolo fondamentale nella conservazione del patrimonio architettonico. A causa del loro frequente verificarsi, gli spostamenti degli appoggi sono una delle principali fonti di danno per gli archi in muratura. Tra le potenziali cause di questi spostamenti, le frane a cinematica lenta hanno ricevuto pochissima attenzione da parte della comunità scientifica. La presente tesi è motivata dall'osservazione di danni ingenti negli archi di chiese storiche in muratura interessate da frane a cinematica lenta. Questi fenomeni producono una combinazione di spostamenti verticali e orizzontali agli appoggi, il cui effetto sul comportamento strutturale dell'arco non è mai stato studiato a fondo in letteratura, soprattutto nell’ambito di grandi spostamenti. Alla luce di queste osservazioni, questa tesi si propone di fornire una piena comprensione della meccanica degli archi in muratura soggetti a grandi spostamenti degli appoggi, con particolare attenzione agli spostamenti inclinati. La metodologia utilizzata per raggiungere questo obiettivo ha incluso sia prove sperimentali che analisi numeriche su un arco ribassato in muratura di giunti a secco in piccola scala, in cui sono state applicate diverse combinazioni di spostamenti orizzontali e verticali in corrispondenza di un appoggio. Le simulazioni numeriche sono state eseguite nell’ambito dei gradi spostamenti utilizzando due diversi approcci numerici basati su una modellazione ad elementi finiti (FE) ed una modellazione a blocchi rigidi (RB). È stata adottata una strategia di micro-modellazione, in cui l'arco è stato modellato come un assemblaggio di blocchi, molto rigidi e infinitamente resistenti a compressione nel modello FE e infinitamente rigidi nel modello RB. In entrambi i modelli i blocchi erano collegati da interfacce senza resistenza a trazione. Simulazioni numeriche preliminari, finalizzate a progettare il set-up sperimentale e ad acquisire una prima conoscenza della risposta dell'arco, sono state eseguite considerando l'arco come una struttura rigida non resistente a trazione. A tal fine, nel modello FE è stato adottato un valore molto elevato di rigidezza normale delle interfacce. Un’ampia campagna sperimentale è stata eseguita su un modello in scala 1:10 costruito come un assemblaggio a secco di blocchi realizzati con un materiale composito bicomponente. I risultati delle prove sperimentali hanno permesso, per la prima volta in letteratura, di valutare con precisione l'effetto della direzione degli spostamenti imposti sulla risposta dell'arco nell’ambito dei grandi spostamenti. Il confronto tra i risultati numerici e sperimentali ha mostrato che i modelli numerici non erano in grado di cogliere in maniera accurata la risposta sperimentale, specialmente in termini di spostamento ultimo al collasso. Al fine di indagare le ragioni di questa discrepanza, è stata quindi eseguita un'analisi di sensitività relativa all’effetto della rigidezza normale delle interfacce sulle previsioni del modello FE. I risultati hanno dimostrato che la differenza tra risultati numerici e sperimentali poteva essere attribuita alle imperfezioni, e conseguente deformabilità, delle interfacce del modello fisico. Una strategia per includere le imperfezioni nella modellazione numerica, consistente nel calibrare la rigidezza normale delle interfacce sulla base dei
This page is intentionally left blank.
xvii LIST OF FIGURES Figure 2-1 - Identification of churches located on active landslides: the case of Sant’Olcese church in Sant’Olcese (CH_13) (Regione Liguria 2017). .......................................................................................13 Figure 2-2 Location of the churches analysed in the Ligurian territory. .....................................................15 Figure 2-3 Position of the additional churches on landslide maps: a) Nostra Signora della Bastia Sanctuary in Bastia (CH_29), located close to active landslides (Autorità di bacino distrettuale del fiume Po 2017), b) San Martino church in Cembrano (CH_32), located close to a Pg3 area (Regione Liguria 2017). ....15 Figure 2-4 Superimposition between the maps of the Atlante dei Centri Abitati Instabili della Liguria (Federici and Chelli 2007) and the Carte della Suscettività al Dissesto (Regione Liguria 2017) for San Pietro in Vincoli church in Ville San Pietro (CH_4). ..............................................................................17 Figure 2-5 Evidence of ground movements in the surroundings of the churches inspected: a) cracks in neighbouring buildings, b) cracks in the retaining wall of the embankment on which the church parvis is resting, c) cracks in road surfaces, d) inclined trees. ...............................................................................18 Figure 2-6 Morphology of the Ligurian territory: a) hilly and scarcely urbanized areas, b) sections of the slopes where the churches under consideration are located (where Δh = h – hmin, being hmin the minimum height above sea level in the length (l) of the slope section considered for each church). .....................20 Figure 2-7 Damage of floors: a) cracks on step treads and balustrades bases (CH_17), b) parallel gaps among tiles (CH_29), c) cracks propagating from floor to wall (CH_28), d) sinking of floors (CH_15). .................................................................................................................................................................21 Figure 2-8 Damage of walls: a) cracks in the façade wall next to openings (CH_3), b) diagonal cracks in longitudinal walls propagating from the level of the ground (CH_9), c) vertical cracks increasing in width with height at the middle span of the wall (CH_32), d) vertical cracks in lateral walls extending from the level of the ground and continuing up into vaults, e) rigid rotation producing out-of-plumbness of longitudinal walls and loss of horizontality of metallic tie-rods (CH_8). ...............................................22 Figure 2-9 Damage in arches and vaults: a) widespread cracking (CH_32), b) large deformations (CH_13). .................................................................................................................................................................23 Figure 2-10 Damage patterns congruent with the estimated landslide direction: a) CH_29, b) CH_25. ....24 Figure 2-11 Recurrent types of damage classified by damage level. ..........................................................25 Figure 2-12 Global damage mechanism: a) Hogging, b) Shear deformation, c) Global rigid rotation, d) Extension. ................................................................................................................................................26 Figure 2-13 Cracks patterns observed in the arches (deterioration of the plaster indicated with a dotted line): a-b-c) diagonal cracks (CH_13, CH_22, CH_4), d) symmetrical crack pattern (CH_32), e-f-g-h) asymmetrical crack patterns (CH_4, CH_32, CH_29, CH_13). .............................................................27 Figure 2-14 In-plane deformations in the arches: a) arches of the lateral chapels, b-c-d) arches separating the different bays of the church. ..............................................................................................................28 Figure 2-15 Crack pattern and deformations in Nostra Signora della Bastia Sanctuary (CH_29): a) large deformation and cracks in the transverse arches and barrel vaults of the central nave, b) deformed profile
xviii LIST OF FIGURES xviii (section AA) obtained from the laser scanner survey (Mamone 2017), c) damage pattern of walls, arches and vaults (estimated landslide direction indicated with an arrow). ...................................................... 30 Figure 2-16 Crack patterns and deformations observed in the transverse arches 1 (left) and 2 (right) (located in the plan of the building in Figure 2-17) of San Carlo church in Cassingheno (CH_28): a) large deformations, b) crack close to mid-span, c) arch profile as obtained from the laser scanner survey (Cabella and Sacco 2021). ...................................................................................................................... 31 Figure 2-17 Damage survey of San Carlo church in Cassingheno (CH_28) (estimated landslide direction indicated with an arrow). ........................................................................................................................ 32 Figure 2-18 Crack patterns of masonry vaults: a) longitudinal cracks (CH_28), b) transverse cracks (CH_17), c) diagonal cracks (CH_4), d) cracks continuous between vault and supporting wall (CH_22), e) cracks at the intersection between arches and vaults (CH_32), f) cracks at the connection between vault and supporting wall (CH_2). ......................................................................................................... 33 Figure 2-19 Typical cracks observed in cross vaults: a) crack along one of the diagonals (CH_22), b) parallel diagonal cracks (CH_22), c) diagonal cracks not passing through the keystone, d) longitudinal cracks. ................................................................................................................................................................ 34 Figure 2-20 Typical cracks observed in barrel vaults: a) longitudinal cracks, b) diagonal cracks. ............ 34 Figure 2-21 Large deformations observed in cross vaults (a) and barrel vaults (b). .................................. 35 Figure 2-22 Recurrent damage pattern observed in the vaults. Multiple diagonal cracks widespread throughout the building, all oriented in the same direction and parallel to the gaps of the floor: a) CH_ 22, b) CH_13. (Estimated landslide direction indicated with an arrow.) ............................................... 35 Figure 2-23 Recurrent damage patterns of masonry vaults. Crack repeated with the same pattern in each bay (CH_32): a-b) cracks propagating from the walls and continuing up into arches and vaults, b) damage survey of the entire church (estimated landslide direction indicated with an arrow). ............................ 36 Figure 3-1 Experimental test on full-scale models of arches and vaults on moving supports: a) segmental brick arch subjected to vertical (top) and inclined (bottom) support displacements (Zampieri et al. 2018a), b) timbrel brick cross vault subjected to vertical cyclic displacements of one support (Torres et al. 2019b). ................................................................................................................................................................ 44 Figure 3-2 Experimental tests on small-scale models of arches and vaults on moving supports: a) segmental dry-joint arch made of cast concrete voussoirs (Ochsendorf 2006), b) segmental arch made of brick voussoirs bonded by mortar (Masciotta 2020), c) 3D-printed cross vault (Rossi et al. 2016), d) 3D-printed pavilion vault (Rossi et al. 2017). ........................................................................................................... 45 Figure 3-3 Position of the three initial hinges in arches on horizontal spreading supports: a) symmetrical hinge configuration for arches without keystone (Galassi et al. 2018), b-c-d) asymmetrical hinge configuration for arches with keystone (Galassi et al. 2018, 2020). ...................................................... 47 Figure 3-4 Position of the three initial hinges in arches on horizontal closing supports: a) extrados hinges opening at the haunches, b) extrados hinges opening at the springings (Romano 2005). ...................... 47 Figure 3-5 Position of the three initial hinges in arches subjected to the vertical downward displacement of one support (Galassi et al. 2018). ........................................................................................................... 48
LISTE OF FIGURES xix Figure 3-6 Evolution of the damage configuration up to collapse (the hinge movement is clearly visible in b-c-d) (Romano 2005). ............................................................................................................................48 Figure 3-7 Collapse mechanism of arches on horizontal spreading supports: four-hinge mechanism in segmental (a, Alforno et al. 2020) and pointed (b, Galassi et al. 2020) arches, c) five-hinge mechanism (Romano 2005), d) snap-through failure (Romano 2005). ......................................................................49 Figure 3-8 Collapse mechanism for a segmental arch subjected to an inclined (45° with respect to the horizontal) displacement of one support (Zampieri et al. 2018b). ..........................................................50 Figure 3-9 Stability domain of a circular arch subjected to large support displacements (Smars 2010). ...51 Figure 3-10 – Thrust line analysis-based iterative procedure to study the collapse state of rigid-block circular arches on horizontal spreading supports (Ochsendorf 2002, 2006). ..........................................52 Figure 3-11 Application of the kinematic approach to study the stability of elliptical arches on horizontal spreading supports (Di Carlo and Coccia 2020). ....................................................................................54 Figure 3-12 Comparison between DEM and 2D thrust line analysis to investigate the stability of groin vaults and arches with varying geometries under horizontal and vertical support displacements (McInerney and DeJong 2015). ...............................................................................................................56 Figure 3-13 Comparison of collapse mechanisms obtained from experimental tests (left) and DEM (right) for a masonry cross vault subjected to the diagonal (a) and transverse (b) displacement of one support (Van Mele et al. 2012) . ...........................................................................................................................57 Figure 3-14 FE micro-modelling of a dry-joint masonry cross vault subjected to an increasing horizontal support displacement ux: evolution of the damage configuration (Alforno et al. 2020). ........................59 Figure 3-15 Application of a 3D non-standard contact-based distinct blocks model to study the response of a pointed barrel vault to vertical displacements along one edge (D’Altri et al. 2020). ...........................60 Figure 3-16 Damage mechanism for pointed arches on horizontal spreading supports: a) numerical prediction, b) experimental evidence (Galassi et al. 2020). ....................................................................61 Figure 3-17 Effect of the presence of the keystone on the collapse mechanism of circular arches subjected to horizontal support displacements: a) four-hinge asymmetrical mechanism for arches with keystone, b) five-hinge symmetrical mechanism for arches without keystone (Galassi et al. 2020). .........................61 Figure 4-1 Micro-modelling strategy and application of support displacements. .......................................70 Figure 4-2 FE micro-modelling. ..................................................................................................................70 Figure 4-3 Coulomb friction criterion adopted in the FE model (DIANA FEA BV 2017). .......................71 Figure 4-4 a) Rigid block model of a circular arch subjected to support displacements; b) Rigid block i, surface j and contact point k. ...................................................................................................................72 Figure 4-5 a) Dead loads and contact forces at block i and b) kinematic variables and normal gap g0k at block centroid i and contact point k. .......................................................................................................73 Figure 4-6 – Comparison between the experimental results by Ochsendorf (2002, 2006) and the numerical results obtained from FE analyses (presented in terms of span increase at collapse x,u/L vs. interface normal stiffness kn) and RB analyses: a) circular arch, b) segmental arch. .............................................75
xx LIST OF FIGURES xx Figure 4-7 - Hinge opening in the FE model for: a) kn = 0.1 N/mm3 and b) kn = 48 N/mm3 (results shown in terms of compressive stresses in the interfaces). .................................................................................... 75 Figure 4-8 – Collapse mechanisms for Ochsendorf’s circular arch: a) FE model ( x,u/L = 16.6 %) and b) RB model ( x,u/L = 16.6 %) (initial and final hinge locations of hinges A, B and C are indicated as A0, B0, C0 and Au, Bu, Cu, respectively). .................................................................................................................. 76 Figure 4-9 – Evolution of the hinge configuration for Ochsendorf’s segmental arch. RB model: a) initial hinge configuration, b) hinge configuration before the intrados hinge movement ( x/L = 7.0%), c) hinge configuration after the intrados hinge movement ( x/L = 7.4%), d) collapse ( x,u/L = 7.4%). FE model: e) initial hinge configuration, bf) last convergent configuration ( x/L = 7.4 %). ....................................... 77 Figure 4-10 – Curves horizontal reaction Rx vs. span increase x/L obtained from the FE and RB analyses for a) the circular arch and b) the segmental arch. ................................................................................. 78 Figure 4-11 – Geometry of the considered segmental arch (dimensions in mm). ...................................... 79 Figure 4-12 – FE model: deflection ratio z,u/L at collapse vs. interface normal stiffness kn. .................... 80 Figure 4-13 – Initial hinge configuration obtained from the FE model (left, results presented in terms of compressive stresses in the interfaces) and RB model (right): a) sequence I-E-E ( = 0°) , b) sequence I- E-I ( = 90°). .......................................................................................................................................... 81 Figure 4-14 - Collapse mechanisms obtained from the FE model (left, results presented in terms of compressive stresses in the interfaces) and RB model (right): a) = 0°, b) = 15°, c) = 20°, d) = 30°, e) = 45°, f) = 90°. ..................................................................................................................... 82 Figure 4-15 - Hinge position vs. displacement applied (expressed in terms of deflection ratio z/L and span increase x/L) for values of the angle between 0° and 90° as obtained from FE and RB analyses: a) = 0°, b) = 5°, c) = 10°, d) = 15°, e) = 20°, f) = 25°, g) = 30°, h) = 35°, i) = 40°, l) = 45°, m) = 90°. ...................................................................................................................................... 84 Figure 4-16 - Support reaction-displacement curves obtained from FE and RB analyses for a) = 0° and b) = 90°: curves vertical reaction Rz vs. deflection ratio z/L, and curves horizontal reaction Rx vs. span increase x/L. .......................................................................................................................................... 85 Figure 4-17 – Support reaction-displacement curves for between 0° and 45°, and equal to 90°: curves vertical reaction Rz vs. deflection ratio z/L obtained from FE analyses (a) and RB analyses (c); curves horizontal reaction Rx vs. span increase x/L obtained from FE analyses (b) and RB analyses (d). Comparison with the minimum thrust calculated by graphic statics Rx,min is provided in b) and d). ...... 86 Figure 4-18 – Results obtained at collapse from the FE and RB analyses when varying the angle between 0° and 90° (modes I, II and III are also indicated): a) deflection ratio at collapse z,u/L, b) span increase at collapse x,u/L, c) vertical support reaction at collapse Rz,u and d) horizontal support reaction at collapse Rx,u. ......................................................................................................................................................... 88 Figure 4-19 – Limit displacement domain for the segmental arch under consideration (modes I, II and III are also indicated). .................................................................................................................................. 89 Figure 4-20 - Deflection ratio at collapse z,u/L vs. number of voussoirs for = 0°. ................................. 90
LISTE OF FIGURES xxi Figure 4-21 - Radial position of hinge A at collapse, , vs. number of voussoirs for = 0°. ....................90 Figure 4-22 – Radial position at collapse of hinge A, , and deflection ratio at collapse, z,u/L, for arches with a) 5, b) 8, c) 11, d) 12, e) 19 and f) 20 voussoirs ( t indicates the radial position of hinge A in the theoretical continuous arch). ...................................................................................................................91 Figure 4-23 - Span increase at collapse x,u/L vs. number of voussoirs for = 90°. ..................................92 Figure 4-24 – Limit displacement domains for arches with 28, 35, 55 and 500 (theoretical continuous arch) voussoirs. .................................................................................................................................................93 Figure 5-1 Geometry of the arch mockup (in mm). ....................................................................................98 Figure 5-2 Bicomponent composite prisms tested under uniaxial compression. ........................................99 Figure 5-3 Preparation of the silicon moulds: a) aluminium matrices placed in the wooden formwork; b) pouring of the silicone. ............................................................................................................................99 Figure 5-4 Manufacturing process of the arch voussoirs: a) mixing of the two components, b) application of a small amount of material on the internal surface of the mould, c) pouring of the mixture into the mould, d) mechanical vibration of the mould e) hardening of the mixture, f) voussoirs ready to be used. ...............................................................................................................................................................100 Figure 5-5 Production of the blocks of the piers: a) aluminium matrix; b) silicone mould; block before (c) and after (d) hardening. .........................................................................................................................101 Figure 5-6 Construction of the physical model of the arch: a) positioning of the blocks of the piers, b) positioning of the centering, c-d) arch construction by placing the voussoirs at the extrados of the centering, e-f-g) centering removal, g) physical model after the removal of the centering. .................103 Figure 5-7 Detail views of the scaled arch: a) intrados, b) extrados. ........................................................104 Figure 5-8 Testing machine: a) 3D CAD model, b) front view, c) lateral view. .......................................105 Figure 5-9 System of guides and stepping motors to impose vertical (a) and horizontal (b) support displacements. .......................................................................................................................................106 Figure 5-10 System of load cells to measure the support reactions: a) 3D view, b) 2D view of the lower plate where the load cells are mounted, 3) detail view of one load cell used to measure the vertical reaction, 4) detail view of the solution adopted to measure the horizontal reaction. ............................107 Figure 5-11 Infrared system to track the displacements of the blocks: a) reflective markers, b) targeted points. ....................................................................................................................................................108 Figure 5-12 Reference scheme for the hinge position at collapse for = 0° (a) and = 90° (b). ............109 Figure 5-13 Damage evolution for = 0°: a) z/L = 1.9%, b) z/L = 6.6%, c) z/L = 12.2%, d) z/L = 13.1%, e) collapse for z/L = 16.5%, f) unstable configuration corresponding to z/L = 16.5%. ......................111 Figure 5-14 Damage evolution for = 5°: a) z/L = 3.8%, b) z/L = 6.6%, c) z/L = 7.5%, d) z/L = 10.3%, e) collapse for z/L = 13.8%, f) unstable configuration corresponding to z/L = 13.8%. ......................112 Figure 5-15 Damage evolution for = 10°: a) z/L = 3.8%, b) z/L = 5.6%, c) z/L = 7.5%, d) z/L = 9.4%, e) collapse for z/L = 11.9%, f) unstable configuration corresponding to z/L = 11.9%. ......................113
xxii LIST OF FIGURES xxii Figure 5-16 Damage evolution for = 15°: a) z/L = 3.0%, b) z/L = 4.7%, c) z/L = 6.6 %, d) z/L = 9.1%, e) collapse for z/L = 9.1%, f) unstable configuration corresponding to z/L = 9.1%. ......................... 114 Figure 5-17 Damage evolution for = 25°: a) z/L = 2.8%, b) z/L = 3.8%, c) z/L = 4.7%, d) z/L = 5.6%, e) collapse for z/L = 7.6%, f) unstable configuration corresponding to z/L = 7.6%. ......................... 115 Figure 5-18 Damage evolution for = 35°: a) z/L = 1.9%, b) z/L = 3.2%, c) z/L = 4.7%, d) hinge movement for z/L = 5.5%, e) collapse for z/L = 5.5%, f) unstable configuration corresponding to z/L = 5.5%. ................................................................................................................................................. 116 Figure 5-19 Damage evolution for = 75°: a) z/L = 0.6%, b) z/L = 0.8%, c-d) hinge movement for z/L = 1.0%, e) collapse for z/L = 1.0%, f) unstable configuration corresponding to z/L = 1.0%. ............... 117 Figure 5-20 Damage evolution for = 90°: a) x/L = 2.8%, b) x/L = 3.2%, c) x/L = 3.4%, d) hinge movement for x/L = 3.7%, e) collapse for x/L = 3.7%, f) unstable configuration corresponding to x/L = 3.7%. ................................................................................................................................................. 118 Figure 5-21 Thrust line obtained by graphic statics: a) = 0°, b) = 15°, c) = 20°, d) = 25°, e) = 30°, f) = 35°. ..................................................................................................................................... 120 Figure 5-22 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs ( z,v) and the change in the distance between adjacent voussoirs ( dv) with respect to the initial distance dv,0. ................................................................................................................................ 121 Figure 5-23 Vertical displacement z,v of the voussoirs between hinge B and the right support (identified in Figure 5-22), net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) = 0°, b) = 5°, c) = 10°, d) = 15°, e) = 20°, f) = 25°, g) = 30°, h) = 35°, i) = 40°, l) = 45°, m) = 60°, n) = 75°. .................................................... 125 Figure 5-24 Change in the distance between markers of adjacent voussoirs, dv, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 0°: a) markers 1e-14e, b) markers 25i- 33i and c) markers 55i-RS (right support), to detect the opening of hinges A, B and C, respectively. 128 Figure 5-25 Change in the distance between markers of adjacent voussoirs, dv, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 10° : a) markers 1e-14e, b) markers 25i- 33i and c) markers 55i-RS (right support), to detect the opening of hinges A, B and C, respectively. 129 Figure 5-26 Change in the distance between markers of adjacent voussoirs, dv, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 20°: a) markers 1e-14e, b) markers 25i- 33i and c) markers 37e-51e, to detect the opening of hinges A, B and C, respectively. ........................ 130 Figure 5-27 Change in the distance between markers of adjacent voussoirs, dv, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 30°: a) markers 1e-14e, b) markers 25i- 33i and c) markers 37e-51e, to detect the opening of hinges A, B and C, respectively. ........................ 131 Figure 5-28 Change in the distance between markers of adjacent voussoirs, dv, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 75°: a) markers 1e-14e, b) markers 25i- 33i and c) markers 37e-51e, to detect the opening of hinges A, B and C, respectively. ........................ 132
LISTE OF FIGURES xxiii Figure 5-29 Support reaction-displacement curves at the right and left supports for = 0°: a) curves horizontal reaction Rx/W vs. deflection ratio z/L, b) curves vertical reaction Rz/W vs. deflection ratio z/L. .......................................................................................................................................................134 Figure 5-30 Support reaction-displacement curves at the right and left supports for = 30°: a) curves horizontal reaction Rx/W vs. deflection ratio z/L, b) curves vertical reaction Rz/W vs. deflection ratio z/L. .......................................................................................................................................................135 Figure 5-31 Support reaction-displacement curves at the right and left supports for = 45°: a) curves horizontal reaction Rx/W vs. deflection ratio z/L, b) curves vertical reaction Rz/W vs. deflection ratio z/L. .......................................................................................................................................................135 Figure 5-32 Support reaction-displacement curves at the right and left supports for = 90°: a) curves horizontal reaction Rx/W vs. span increase x/L, b) curves vertical reaction Rz/W vs. span increase x/L. ...............................................................................................................................................................135 Figure 5-33 Support reaction-displacement curves at the right support when varying : a) curves horizontal reaction Rx/W vs. span increase x/L, b) curves vertical reaction Rz/W vs. span increase x/L, c) curves horizontal reaction Rx/W vs. deflection ratio z/L, b) curves vertical reaction Rz/W vs. deflection ratio z/L. .......................................................................................................................................................136 Figure 5-34 Results obtained at collapse when varying the angle between 0° and 90°: a) deflection ratio at collapse z,u/L, b) span increase at collapse x,u/L, c) vertical support reactions at collapse Rz,u, d) horizontal support reactions at collapse Rx,u. .......................................................................................137 Figure 5-35 Limit displacement domain for the tested arch. .....................................................................138 Figure 6-1 Collapse mechanisms from FE analyses (left) and experimental tests (right): a) = 0°, b) = 20°, c) = 90°. (Minor distributed openings are indicated with a dotted circle). .................................144 Figure 6-2 Change in the distance between markers of adjacent voussoirs, dv, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 0° as obtained from FE analysis (left) and experimental tests (right): a) markers 1e-14e, b) markers 25i-33i and c) markers 55l-RS (right support), to detect the opening of hinges A, B and C, respectively. ....................................................................145 Figure 6-3 Comparison between numerical (FEM and RBM) and experimental results when varying between 0° and 90°: a) deflection ratio at collapse z,u/L, b) span increase at collapse x,u/L. ..............146 Figure 6-4 Comparison between numerical (FEM and RBM) and experimental results in terms of limit displacements domain. ..........................................................................................................................147 Figure 6-5 Comparison between FE and experimental results for = 0°: a) curves horizontal reaction at the right support Rx/W vs. deflection ratio z/L, b) curves vertical reaction at the right support Rz/W vs. deflection ratio z/L. ..............................................................................................................................148 Figure 6-6 Comparison between FE and experimental results for = 20°: a) curves horizontal reaction at the right support Rx/W vs. deflection ratio z/L, b) curves vertical reaction at the right support Rz/W vs. deflection ratio z/L. ..............................................................................................................................148
xxiv LIST OF FIGURES xxiv Figure 6-7 Comparison between FE and experimental results for = 90°: a) curves horizontal reaction at the right support Rx/W vs. span increase x/L, b) curves vertical reaction at the right support Rz/W vs. span increase x/L. ........................................................................................................................................ 148 Figure 6-8 Comparison between numerical (FEM and RBM) and experimental results when varying between 0° and 90°: a) vertical reaction Rv,u/W at the right support at collapse, b) horizontal reaction Rx,u/W at the right support at collapse. .................................................................................................. 149 Figure 6-9: Deflection ratio at collapse u/L vs. interface normal stiffness kn. ......................................... 149 Figure 6-10: Collapse mechanisms for different values of the interface normal stiffness kn: a) 0.1 N/mm3 ( z,u/L = 3.8%), b) 1 N/mm3 ( z,u/L = 12.1%), c) 10 N/mm3 ( z,u/L = 20.4%), d) 100 N/mm3 ( z,u/L = 21.2%). (Results presented in terms of compressive stresses in the interfaces.) .................................. 150 Figure 6-11: Hinge position at collapse vs. interface normal stiffness kn. ................................................ 151 Figure 6-12 Collapse mechanism obtained from the RB model for an arch of reduced thickness. .......... 152 Figure 6-13 Collapse mechanism obtained for = 20°: a) kn = 2 N/mm3 ( z,u/L = 8.1%), b) kn = 3 N/mm3 ( z,u/L = 9.6%). ..................................................................................................................................... 153 Figure 6-14 Support reaction-displacement curves for E = 590 MPa and E = 941 MPa: a) curve horizontal reaction Rx/W vs. deflection ratio z/L for = 0°, b) curves horizontal reaction Rx/W vs. span increase x/L for = 10°, = 20° and = 90°. ................................................................................................. 154 Figure 6-15 Comparison between experimental results and numerical predictions (RBM and FEM for kn = 3 N/mm3 and kn = 48 N/mm3) when varying between 0° and 90°: a) deflection ratio at collapse z,u/L, b) span increase at collapse x,u/L. ........................................................................................................ 155 Figure 6-16 Comparison between experimental results and numerical predictions (RBM and FEM for kn = 3 N/mm3 and kn = 48 N/mm3) in terms of limit displacement domain. ................................................ 156 Figure 6-17 Collapse mechanisms from FE analyses (kn = 3 N/mm3, left) and experimental tests (right) : a) = 0°, b) = 5°, c) = 10°, d) = 15°, e) = 20°, f) = 25°, g) = 30°, h) = 35°, i) = 40°, l) = 45°, m) = 60°, n) = 75°, o) = 90°. (Minor and distributed opening are indicated with a dotted circle.) ................................................................................................................................................... 159 Figure 6-18 Distribution of compressive stresses in the interfaces of the FE model: a) = 20°, a) = 30°, a) = 40°, a) = 60°. .......................................................................................................................... 160 Figure 6-19 Damage evolution for = 0°. Numerical model (kn = 3 N/mm3, left) vs. experimental model (right): a) z/L = 6.6%, b) z/L = 9.4%, c) z/L = 12.2%, d) collapse for z,u/L = 16.5% in the numerical model and z,u/L = 16.5% in the experimental model. .......................................................................... 162 Figure 6-20 Damage evolution for = 20°. Numerical model (kn = 3 N/mm3, left) vs. experimental model (right): a) z/L = 0.6%, b) z/L = 2.8%, c) z/L = 5.6%, d) collapse for z,u/L = 9.6% in the numerical model and z,u/L = 9.1% in the experimental model. (Minor and distributed opening are indicated with a dotted circle.) ........................................................................................................................................ 164
LISTE OF FIGURES xxv Figure 6-21 Damage evolution for = 45°. Numerical model (kn = 3 N/mm3, left) vs. experimental model (right): a) z/L = 2.4%, b) z/L = 3.5%, c) collapse for z,u/L = 3.8% in the numerical model and z,u/L = 3.7% in the experimental model, d) unstable configuration corresponding to z/L = 4.0% in the numerical model and z/L = 3.7% in the experimental model. ..............................................................................166 Figure 6-22 Vertical displacement z,v of the voussoirs between hinge B and the right support (identified in Figure 5-22), net of the imposed vertical displacement z, vs. imposed displacement (expressed in terms of deflection ratio z/L for between 0° and 75° and span increase x/L for equal to 90°) from FE analyses (kn = 3 N/mm3, left) and experimental tests (right): a) = 0°, b) = 5°, c) = 10°, d) = 15°, e) = 20°, f) = 25°, g) = 30°, h) = 35°, i) = 40°, l) = 45°, m) = 60°, n) = 75°, o) = 90°. ...............................................................................................................................................................171 Figure 6-23 Comparison between numerical (left) and experimental (right) results for = 0°. Change in the distance between markers of adjacent voussoirs, dv, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 55l-RS (right support), to detect the opening of hinges A, B and C, respectively. .....................................................173 Figure 6-24 Comparison between numerical (left) and experimental (right) results for = 5°. Change in the distance between markers of adjacent voussoirs, dv, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 55l-RS (right support), to detect the opening of hinges A, B and C, respectively. .....................................................174 Figure 6-25 Comparison between numerical (left) and experimental (right) results for = 20°. Change in the distance between markers of adjacent voussoirs, dv, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 37e-51e, to detect the opening of hinges A, B and C, respectively. ...................................................................................175 Figure 6-26 Comparison between numerical (left) and experimental (right) results for = 30°. Change in the distance between markers of adjacent voussoirs, dv, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 37e-51e, to detect the opening of hinges A, B and C, respectively. .........................................................................................176 Figure 6-27 Comparison between experimental results and numerical predictions (RBM and FEM for kn = 3 N/mm3 and kn = 48 N/mm3) when varying between 0° and 90°: a) vertical reaction at the right support at collapse Rv,u/W, b) horizontal reaction at the right support at collapse Rx,u/W. ..................................178 Figure 6-28 Comparison between experimental results and FE predictions (for kn = 3 N/mm3 and kn = 48 N/mm3) for = 0°: a) curves horizontal reaction at the right support Rx/W vs. deflection ratio z/L, b) curves vertical reaction at the right support Rz/W vs. deflection ratio z/L. ..........................................179 Figure 6-29 Comparison between experimental results and FE predictions (for kn = 3 N/mm3 and kn = 48 N/mm3) for = 20°: a) curves horizontal reaction at the right support Rx/W vs. deflection ratio z/L, b) curves vertical reaction at the right support Rz/W vs. deflection ratio z/L. ..........................................179
2 CHAPTER 1 2 on the structural response of this type of buildings have never been systematically investigated. It is worth noting that this applies not only to landslides, but also, more generally, to all the phenomena involving soil movements. Subsidence and foundation settlements have been addressed only through the analysis of case studies (e.g., Ayensa et al. 2015; Calabresi 2013; Drougkas et al. 2020; Lancellotta 2013; Saloustros et al. 2015; Sánchez et al. 2016; Taliercio and Binda 2007) or single structural elements such as arches and vaults (e.g. D’Altri et al. 2020; Galassi et al. 2018; McInerney and DeJong 2015; Torres et al. 2019a, 2019b; Van Mele et al. 2012). The literature related to churches located in landslide-affected areas has mainly focused on the geotechnical and geological analysis of the slope movement (Cigna et al. 2013; Margottini et al. 2013; Soccodato et al. 2013; Spizzichino et al. 2012) rather than on soil-structure interaction. Among the region in which Italy is divided, Liguria is one of the most affected by landslide phenomena. Liguria is a hilly region of Northern Italy confined within a narrow strip of land bounded to the North by the Alps and Apennines, and to the South by the Ligurian sea. Due to the geographical location, orography as well as morphological and geological setting of the Ligurian territory, landslides frequently occur. As reported in Guzzetti et al. (2004), 1806 landslide events damaged 1233 localities between 1800 and 2001. Furthermore, in 2017, an area of 751.9 km2, equal to 13.9% of the regional territory, was classified as a high or very high landslide hazard zone (Trigila et al. 2018). Within the framework of the National Research Program PRIN 2015 “PERICLES- Protecting the Cultural Heritage from water-soil interaction related threats” (grant n. 2015EAM9S5 from Ministry of Education, University and Research), on-site inspections and damage surveys were performed on a large sample of historic masonry churches located in Liguria in areas affected by slow-moving landslides. This activity was carried out by the thesis author in collaboration with the former Ph.D candidate Ludovica Cambiaggi, Prof. Rita Vecchiattini and Prof. Chiara Calderini from the Department of Civil, Chemical and Environmental Engineering and the Architecture and Design Department of the University of Genoa (Liguria). The main aims of this activity were to describe the damage suffered by historic masonry churches in terms of crack patterns and deformation as well as to identify the damage mechanisms produced by slowmoving landslides. Attention was paid only to the landslides that can be classified as very slow or extremely slow according to the classification provided by Cruden and Varnes (1996). These types of phenomena produce soil displacements that are small in their instantaneous values, as their velocity does not exceed 1.6 m/year and 16 mm/year in the case of very slow and extremely slow landslides, respectively. Notwithstanding the very low speed, slow-moving landslides were found to cause severe damage to masonry structures over time (Antronico 2015; Nicodemo 2017). Extensive and severe damage, congruent with the landslide direction, was detected in several churches of the sample, suggesting the need for further investigation on the effects of slow-moving landslides. In particular, widespread cracks and very large deformations were observed in the arches of the large majority of the churches inspected. Arches have a primary structural role in the skeleton of a masonry church, as they transfer the vertical loads and thrusts transmitted by vaults and roof to pillars and foundations. A full understanding of their structural behaviour is thus essential for the damage and vulnerability assessment of historic masonry churches exposed to slow-moving landslides.
INTRODUCTION 3 Since landslides involve both downward and lateral ground movements (Cooper 2008), they are expected to produce a combination of vertical and horizontal displacements at the arch supports. The assessment of the damage induced by slow-moving landslides to masonry arches thus requires to evaluate their structural performance under inclined support displacements. However, this is a new field of research. Although a large body of recent literature was devoted to investigating purely vertical and horizontal supports displacements, there is still a lack of studies dealing with their combination. It is the motivation of this work to address this gap and provide a full understanding of the mechanics of masonry arches subjected to inclined support displacements. The identification of the damage and collapse mechanisms of these structural elements will help in the interpretation of the crack patterns produced by slow-moving landslides in historic masonry churches. Nevertheless, it is worth noting that the conclusions drawn from this study are not applicable only to the case of slow-moving landslides. Support displacements can be produced by a range of different causes, including foundation settlements, subsidence, leaning of supporting piers and buttresses, and many others. Similarly to slow-moving landslides, these phenomena evolve slowly over time, but they can affect a church over its entire life, causing support displacements to substantially increase and thus producing damage and deformations. If foundations settlements and subsidence result in vertical support displacements, the leaning of piers and buttresses, generally produced by the horizontal thrusts of arches and vaults, causes horizontal support displacements. Since these phenomena often occur simultaneously in historic masonry churches, it is unlikely that the displacements at the arch supports are purely vertical or horizontal. In view of these considerations, this work does not deal with a specific source of support displacements, but it seeks to investigate any type of support displacements that evolve slowly over time. 1.2. OBJECTIVES AND METHODOLOGY The main aim of this thesis is to provide a full understanding of the static behaviour of masonry arches subjected to large support displacements increasing slowly over time. To accomplish this goal, a set of specific objectives was defined as follows: To identify the recurrent crack patterns and deformations caused by slow-moving landslides in arches of historic masonry churches. To gather information on the existing knowledge about the structural behaviour of masonry arches on moving supports. To study the response of masonry arches to inclined support displacements by means of experimental tests and numerical simulations. To assess the effect of the displacement direction on collapse mechanism, hinge position, support reaction-displacement curves, ultimate displacement capacity and support reactions at collapse.
4 CHAPTER 1 4 To evaluate the ability of numerical models to predict the experimental response of masonry arches on moving supports. To propose a strategy to calibrate the numerical models so as to accurately capture the structural behaviour observed in the experimental tests. The methodology followed to accomplish these objectives is presented below. On-site inspections and damage surveys were first carried out on 33 historic masonry churches located in the Liguria region (Italy) in areas affected by slow-moving landslides. The crack patterns and deformations exhibited by arches and vaults were described and critically analysed in an attempt to identify the recurrent damage mechanisms. The existing literature on masonry arches subjected to support displacements was then comprehensively reviewed with the aim to: (i) provide insights in the arch mechanics thanks to the analysis of the results of the experimental investigations, and (ii) present all the computational methods used so far to address this topic. The literature review was also extended to the research works dealing with masonry vaults on moving supports. To evaluate the effect of inclined support displacements on the response of masonry arches, experimental tests and numerical analyses were performed on a segmental scaled dry-joint arch subjected to different combinations of vertical and horizontal support displacements. The experimental tests were performed on a 1:10 small-scale model built as a dry-joint assembly of voussoirs made of a bicomponent composite material. A new testing machine was designed ad hoc to impose vertical, horizontal and inclined displacements at one support of the arch. The numerical simulations were carried out in the framework of large displacements using two different numerical approaches, namely finite element (FE) modelling and rigid block (RB) modelling. With the aim of accurately simulating the experimental tests on a dry-joint voussoir arch, a micro-modelling strategy was adopted. The arch was thus modelled as an assembly of voussoirs, very stiff and infinitely resistant in compression in the FE model and rigid in the RB model, interacting at no-tension friction interfaces. The ability of the two models to simulate the response of masonry arches to large support displacements was evaluated through comparison with experimental results from the literature. Prior to performing the experimental tests, preliminary numerical simulations were carried out to gain a first insight in the response of the arch to different combinations of vertical and horizontal support displacements. A specific aim was to determine the maximum allowable displacement at collapse, which was needed for the design of the experimental set-up. In these preliminary numerical simulations, the arch was analysed as a rigid-no tension structure. To this aim, a very large value of interface normal stiffness, determined based on a sensitivity analysis, was adopted in the FE model. To assess the ability of the numerical models to accurately simulate the experimental response, the numerical predictions were compared to the experimental results. Since some discrepancies were observed, a strategy to calibrate the numerical models was sought. For this purpose, a sensitivity analysis on the effect of the interface normal stiffness adopted in the FE model was performed. The results suggested that this
INTRODUCTION 5 parameter could be used as the variable to tune to obtain a better matching between experimental and numerical results. The interface normal stiffness was thus calibrated according to the experimental evidence, and further FE simulations were carried out to verify the effectiveness of the strategy proposed. Finally, a further experimental test was performed on a small-scale arch made of bicomponent composite voussoirs exhibiting more imperfections. A calibrated FE model was used to simulate the experimental test. The effect of geometrical imperfections on the arch response was evaluated by comparing the experimental and numerical results obtained for the two small-scale models built. 1.3. THESIS OUTLINE This thesis consists of seven chapters. Chapter 1 presents the motivation and background that inspired this research work and states the main aim and specific objectives. Chapter 2 describes the on-site inspections and the damage surveys performed on a sample of historic masonry churches exposed to slow-moving landslide threats. The criteria adopted for the selection of the case studies as well the methodology used to perform on-site inspections and gather data are presented. A brief description of the sample of case studies is also provided. After describing the recurrent crack patterns and deformations observed, the main conclusions obtained from the critical assessment of the surveyed damage are presented. Lastly, the crack patterns and deformations observed in masonry arches and vaults are described and critically analysed. Chapter 3 proposes a comprehensive review of the existing literature for masonry arches and vaults on moving supports. The first part of the chapter reviews in detail the experimental investigations. For masonry arches, the experimental results are analysed to provide a detailed description of the damage and collapse mechanisms experienced. The second and third parts of the chapter describe the computational methods used in the literature to investigate the stability of masonry arches and vaults when subjected to support displacements. A distinction is provided between the analytical and computational methods based on Limit Analysis and modern methods based on finite element, discrete element and rigid block modelling. The ability of the computational methods to predict the experimental results is also discussed. Chapter 4 presents the preliminary numerical analyses carried out on the segmental scaled dry-joint arch chosen as case study in this thesis. The static behaviour of the arch, which is modelled as a rigid-no tension structure, is investigated under different combinations of vertical and horizontal support displacements using FE and RB models. First, both models are validated against experimental results from the literature. A discussion on the value of interface normal stiffness to adopt in the FE model is also presented. Second, the results obtained from FE and RB simulations for the scaled dry-joint arch under study are compared and discussed in detail. Lastly, the sensitivity of the results to the number of voussoirs is investigated. Chapter 5 presents the design, execution and results of the experimental campaign performed on a 1:10 small-scale model of the segmental dry-joint arch under investigation. The arch is subjected to different combinations of vertical and horizontal displacements at one support. Results are obtained in terms of damage evolution, ultimate displacement capacity, displacements of the voussoirs and support reactions.
6 CHAPTER 1 6 Chapter 6 provides a critical interpretation of the experimental tests. The experimental results are first compared to the numerical predictions for the rigid-no tension arch. A strategy to calibrate the numerical models on the basis of the experimental is then proposed, and further numerical analyses are performed using a calibrated FE model. Lastly, the effects of geometrical imperfections on the experimental response of the small-scale arch are evaluated by performing a further experimental test as well as numerical simulations on a FE calibrated model. Chapter 7 summarizes the results and provides suggestions for future works. 1.4. RESEARCH DISSEMINATION The work presented in this thesis has resulted in the following scientific publications: Papers in peer-reviewed international journals Ferrero, C., Calderini, C., Portioli, F., and Roca P. (2021) Large displacement analysis of dry-joint masonry arches subject to inclined support movements. Engineering Structures, 238, 112244. https://doi.org/10.1016/j.engstruct.2021.112244. Ferrero, C., Rossi, M., Roca, P. and Calderini, C. (2021) Experimental and numerical analysis of a scaled dry-joint arch on moving supports. International Journal of Masonry Research and Innovation, 6(4) (Special issue on Simple Mechanical Models for Unreinforced Historic Masonry Constructions, in press). https://doi.org/10.1504/IJMRI.2021.10035577. Ferrero, C., Cambiaggi, L., Vecchiattini, R. and Calderini, C. (2021) Damage assessment of historic masonry churches exposed to slow-moving landslides. International Journal of Architectural Heritage (In press). https://doi.org/10.1080/15583058.2020.1799259. Peer-reviewed conference papers Ferrero, C., Cambiaggi, L., Fenialdi, A., Roca, P., Vecchiattini, R. and Calderini, C. Slow-moving landslide damage assessment of historic masonry churches: some case-studies in Italy. 12th International Conference on Structural Analysis of Historical Constructions - SAHC2021 (Accepted; oral presentation at the forthcoming conference). Cambiaggi, L., Ferrero, C., Berardi, R., Calderini, C. and Vecchiattini, R. Effect of slow-moving landslides on churches in the Liguria region: a geotechnical approach. 12th International Conference on Structural Analysis of Historical Constructions - SAHC2021 (Accepted). Ferrero C., Rossi, M., Roca P. and Calderini, C. Effect of geometrical imperfections on the response of dry-joint masonry arches to support settlements. 12th International Conference on Structural Analysis of Historical Constructions - SAHC2021 (Accepted; oral presentation at the forthcoming conference).
INTRODUCTION 7 Presentations at international conferences Ferrero, C., Calderini, C., Portioli, F., and Roca P. (2021). Collapse mechanisms of masonry arches on moving supports. 14th WCCM & ECCOMAS Congress 2020, Virtual Congress 11-15 January 2021.
8 CHAPTER 1 8 REFERENCES Antronico, L., L. Borrelli, R. Coscarelli, and G. Gullà. 2015. Time evolution of landslide damages to buildings: the case study of Lungro (Calabria, southern Italy). Bulletin of Engineering Geology and the Environment 74: 47-59. Ayensa, A., B. Beltran, E. Ibarz, and L. Gracia. 2015. Application of a new methodology based on Eurocodes and finite element simulation to the assessment of a romanesque church. Construction and Building Materials 101(1): 287-297. Calabresi G. 2013. The role of geotechnical engineers in saving monuments and historic sites. Kerisel Lecture. In: Proceedings of the 18th International Conference on Soil Mechanics and Geotechnical Engineering, ed. P. Delage, J. Desrues, R Frank, A. Puech, and F. Schlosser, 71–83, Paris, France: Presses des Ponts. Calderini, C., and G. De Matteis. 2020. Report. Task 4.8_Modelli e curve di fragilità delle chiese. WP4_MAppe di Rischio e Scenari di danno sismico (MARS). Progetto ReLUIS-DPC 2019-2021. Canuti, C., S. Carbonari, A. Dall’Asta, L. Dezi, F. Gara, G. Leoni, M. Morici, E. Petrucci, A. Prota, and A. Zona. 2019. Post-Earthquake Damage and Vulnerability Assessment of Churches in the Marche Region Struck by the 2016 Central Italy Seismic Sequence. International Journal of Architectural Heritage. Cigna, F., V. Liguori, C. Del Ventisette, and N. Casagli. 2013. Landslide impacts on Agrigento’s Cathedral imaged with radar interferometry. In: Landslide Science and Practice, ed. C. Margottini, P. Canuti and K. Sassa, 475-481. Springer Berlin Heidelberg. Cooper, A. H. 2008. The classification, recording, databasing and use of information about building damage caused by subsidence and landslides. Quarterly Journal of Engineering Geology & Hydrogeology 41: 409-424. Cruden, D.M. and D.J. Varnes. 1996. Landslide types and processes. In: Landslides: investigation and mitigation, Transportation Research Board, Special Report 247, 36-75. Washington, D.C.: National Academy of Sciences. D’Altri, A.M., S. De Miranda, G. Castellazzi, V. Sarhosis, J. Hudson, and D. Theodossopoulos. 2020. Historic barrel vaults undergoing differential settlements. International Journal of Architectural Heritage 14(8): 1196-1209. https://doi.org/10.1080/15583058.2019.1596332. da Porto, F., B. Silva, C. Costa, and C. Modena. 2012. Macro-scale analysis of damage to churches after earthquake in Abruzzo (Italy) on April 6, 2009. Journal of Earthquake Engineering 16(6): 739–758. De Matteis, G., E. Criber, and G. Brando. 2016. Damage probability matrices for three-nave masonry churches in Abruzzi after the 2009 L’Aquila earthquake. International Journal of Architectural Heritage 10(2–3): 120–145. Doglioni, F., A. Moretti, and V. Petrini. 1994. Le chiese e il terremoto. National Research Council, Trieste, IT: Lint Press (in Italian).
INTRODUCTION 9 Drougkas, A., E. Verstrynge, P. Szekér, G. Heirman, L.E. Bejarano-Urrego, G. Giardina, and K. Van Balen. 2020. Numerical Modeling of a Church Nave Wall Subjected to Differential Settlements: Soil-Structure Interaction, Time-Dependence and Sensitivity Analysis. International Journal of Architectural Heritage 14(8): 1221-38. https://doi.org/10.1080/15583058.2019.1602682 Galassi, S., G. Misseri, L. Rovero, and G. Tempesta. 2018. Failure modes prediction of masonry voussoir arches on moving supports. Engineering Structures 173: 706–17. https://doi:10.1016/j.engstruct.2018.07.015. Guerreiro, L., J. Azevedo, J. Proenca, R. Bento, and M. Lopes. 2000. Damage in ancient churches during the 9th of July 1998 Azores earthquake. Proceedings of the 12th World Conference on Earthquake Engineering, Auckland, New Zealand, paper no. 780. Guzzetti, F., M. Cardinali, P. Reichenbach, F. Cipolla, C. Sebastiani, M. Galli, and P. Salvati. 2004. Landslides triggered by the 23 November 2000 rainfall event in the Imperia Province, Western Liguria, Italy. Engineering Geology 73(2): 229–245. ICOMOS 1994. Nara document on authenticity. In: Conference on Authenticity in Relation to the World Heritage Convention. Nara, Japan. Lagomarsino, S. 2012. Damage assessment of churches after L’Aquila earthquake (2009). Bulletin of Earthquake Engineering 10(1): 73–92. Lagomarsino, S. and S. Podestà. 2004a. Seismic vulnerability of ancient churches. Part 1: damage assessment and emergency planning. Earthquake Spectra 20(2): 377–394. Lagomarsino, S. and S. Podestà. 2004b. Seismic vulnerability of ancient churches. Part 2: statistical analysis of surveyed data and methods for risk analysis. Earthquake Spectra 20(2): 395–412. Lagomarsino, S. and S. Podestà. 2004c. Damage and vulnerability assessment of churches after the 2002 Molise, Italy, earthquake. Earthquake Spectra 20(S1): S271–S283. Lancellotta, R. 2013. La torre Ghirlandina: Una storia di interazione struttura-terreno. In: XI Croce Lecture. Rivista Italiana di Geotecnica 47(2): 7–37 (in Italian). Margottini, C., D. Spizzichino, and A. Sonnessa. 2013. Landslide risk and monitoring system for conservation of Vardzia monastery, Georgia. In: Geotechnical Engineering for the Preservation of Monuments and Historic Sites, ed. E. Bilotta, A. Flora, S. Lirer, and C. Viggiani, 549-558. London, UK: CRC Press (Taylor & Francis Group). McInerney, J., and M. J. DeJong. 2015. Discrete element modeling of groin vault displacement capacity. International Journal of Architectural Heritage 9(8): 1037-49. http://dx.doi.org/10.1080/15583058.2014.923953 Nicodemo, G. 2017. Vulnerability analysis of buildings in areas affected by slow-moving landslides and subsidence phenomena. PhD diss., University of Salerno.
10 CHAPTER 1 10 Penna, A., C. Calderini, L. Sorrentino, C. F. Carocci, E. Cescatti, R. Sisti, A. Borri, C. Modena, and A. Prota. 2019. Damage to churches in the 2016 central Italy earthquakes. Bulletin of Earthquake Engineering 17(10): 5763-5790. Podestà, S, A. Brignola, E. Curti, S. Parodi, and A. Lemme. 2010. Damage assessment and seismic vulnerability of churches: the Abruzzo earthquake. Ingegneria Sismica 2(1): 21–35 (in Italian). Romão, X., A.A. Costa, E. Paupério, H. Rodrigues, R. Vicente, H. Varum, and A. Costa. 2013. Field observations and interpretation of the structural performance of constructions after the 11 May 2011 Lorca earthquake. Engineering Failure Analysis 34: 670–692. Saloustros S., L. Pelà, P. Roca, and J. Portal. 2015. Numerical analysis of structural damage in the church of the Poblet Monastery, Engineering Failure Analysis 48: 41–61. Sánchez A. R., R. Meli, and M. M. Chávez. 2016. Structural monitoring of the Mexico City cathedral (1990-2014), International Journal of Architectural Heritage 10(2-3): 254-68. Soccodato, F.M, E. Martini, L. Tortoioli and A.M. Mazzi. 2013. The preservation of historical, archaeological and artistic heritage of Orvieto: an interdisciplinary project. In: Geotechnical Engineering for the Preservation of Monuments and Historic Sites, ed. E. Bilotta, A. Flora, S. Lirer, and C. Viggiani, 683-96. London, UK: CRC Press (Taylor & Francis Group). Spizzichino, D., C. Margottini and L.M. Puzzilli. 2012. Landslide risk assessment and management in the archaeological site of Machu Picchu (Peru). In: Geotechnical Engineering for the Preservation of Monuments and Historic Sites, ed. E. Bilotta, A. Flora, S. Lirer, and C. Viggiani, 697-707. London, UK: CRC Press (Taylor & Francis Group). Taliercio, A. and L. Binda. 2007. The Basilica of San Vitale in Ravenna: Investigation on the current structural faults and their mid-term evolution. Journal of Cultural Heritage 8: 99–118. Torres, B., E. Bertolesi, P. A. Calderón, J. J. Moragues, and J. M. Adam. 2019. Experimental investigation of a full-scale timbrel masonry cross vault subjected to vertical settlement. Construction and Building Materials 221: 421–32. https://doi.org/10.1016/j.conbuildmat.2019.06.015. Torres, B., E. Bertolesi, P. A. Calderón, J. J. Moragues, and J. M. Adam. 2019. A full-scale timbrel cross vault subjected to vertical cyclical displacements in one of its supports. Engineering Structures 183: 791-804. https://doi.org/10.1016/j.engstruct.2019.01.054. Trigila, A., C. Iadanza, M. Bussettini, and B. Lastoria. 2018. Dissesto idrogeologico in Italia: pericolosità e indicatori di rischio. Rapporti 287/2018. Istituto Superiore per la Protezione e la Ricerca Ambientale – ISPRA (in Italian). Van Mele, T., J. McInerney, M. J. DeJong, and P. Block. 2012. Physical and computational discrete modelling of masonry vault collapse. In SAHC2012: Proceedings of 8th International Conference on Structural Analysis of Historical Constructions, ed. J. Jasienko, 2552–2560. Dolnośląskie Wydawnictwo Edukacyjne.
11 CHAPTER 2 2. DAMAGE SURVEY OF HISTORIC MASONRY CHURCHES EXPOSED TO SLOW-MOVING LANDSLIDES 2.1. INTRODUCTION This chapter presents the results of the damage survey performed on 33 historic masonry churches located in the Liguria region (Italy) in areas affected by slow-moving landslides. The criteria adopted to select the sample of case studies are described in Section 2.2. The methodology followed to perform on-site inspections and gather data about both churches and landslide movements is presented in Section 2.3. To better characterize the assets investigated, a brief description of the sample, providing information about construction date, layout, dimensions, and past interventions for each church, is also included. Section 2.4 describes the damage observed in the churches and presents the results of a critical damage assessment. The main conclusions regarding the structural response of historic masonry churches to slow-moving landslides are reported in terms of recurrent types of damage, damage levels and overall damage mechanisms. After dealing with the church in its entirety, attention is paid to arches and vaults. Although this thesis is focused on masonry arches only, the structural behaviour of masonry vaults is also analysed, since there is structural continuity between the two structural elements. Furthermore, slow-moving landslides produce the same displacements at the abutments of arches and vaults. In Section 2.5, the cracks patterns and deformations observed in arches and vaults are described in detail and critically analysed in an attempt to identify recurrent damage mechanism. It should be noted that the damage assessment performed in this thesis was mainly based on visual inspections and was aimed to provide the first conclusions about the response of historic masonry churches as well as arches and vaults to slow-moving landslides. Nevertheless, a more accurate interpretation of the damage would require a deep knowledge of history, past alterations, materials, construction details and morphology (i.e. internal composition of structural members and connections) for each building investigated. 2.2. IDENTIFICATION OF THE SAMPLE OF CHURCHES 2.2.1. Churches located on active landslides To select the sample of assets to be investigated, the landslide classification of the Liguria region and the list of heritage buildings protected by the Ministry of Cultural Heritage and Activities were taken into account.
18 CHAPTER 2 18 elevations were traced on site using laser distance meters and measuring tapes. Cracks affecting walls and pillars were marked on the building plan by means of symbols identifying their orientations (vertical, horizontal and diagonal). A classification of the cracks surveyed was also taken into consideration. Cracks were classified according to three levels of width: (i) thin for a width up to 1 mm (the latter included), (ii) medium for a width between 1 mm and 5 mm, and (iii) large for a width equal or larger than 5 mm. Crack width was accurately measured by means of crack scales and callipers (accuracy 0.05 mm) for cracks that were easily accessible, while it was only estimated for cracks located at a significant height from the ground level. When cracks were repointed and did not re-open, crack width was not reported. It is to note that construction joints were identified and distinguished from other damage signs since they are related with the construction process of the building. In addition to the crack pattern, out-of-plumbness of walls and pillars as well as sinking of floors were surveyed and, when possible, measured by means of electric bubble levels or out-of-plumb wires. Lastly, as shown in Figure 2-5, for each church an inspection of the surroundings was performed in order to detect any potential evidence of ground movements: (i) cracks and distortions in neighbouring buildings (Figure 2-5a), (ii) cracks in the retaining wall of the embankment on which the church parvis is resting (Figure 2-5b), (iii) cracks in road surfaces (Figure 2-5c), (iv) inclined street lights or trees (Figure 2-5d). Figure 2-5 Evidence of ground movements in the surroundings of the churches inspected: a) cracks in neighbouring buildings, b) cracks in the retaining wall of the embankment on which the church parvis is resting, c) cracks in road surfaces, d) inclined trees.
DAMAGE SURVEY OF HISTORIC MASONRY CHURCHES EXPOSED TO SLOW-MOVING LANDSLIDES 19 2.3.3. Church sample description The selected sample of assets includes 24 churches, 3 sanctuaries, 3 oratories and 3 chapels (all generically named churches). For each building, Table 3 reports construction date, layout, dimensions, and past interventions. Regarding the construction date, 19 out of the 33 selected buildings date back from the 16th to the beginning of the 19th century, whereas 7 of them were built between the 11th and 15th century. For 7 out of the 33 buildings inspected, the exact construction date is unknown. Table 3 Features of the considered sample of churches. Id Construction date Layout Dimensions in plana Structural interventions Architectural restorations Floor refurbishment CH_1 17th single nave 27 x 11 x x x CH_2 17th single nave 28 x 10 CH_3 16th-17th single nave 26 x 13 x x CH_4 18th central plan 27 x 17 x x CH_5 17th single nave 28 x 8 x x CH_6 13th 3 naves 21 x 13 x CH_7 18th single nave 22 x 9 x x CH_8 17th single nave 16 x 10 CH_9 19th central plan 19 x 15 x CH_10 18th single nave 28 x 14 x CH_11 single nave 17 x 9 x CH_12 16th 3 naves 26 x 13 x x CH_13 17th 3 naves 31 x 18 x CH_14 single nave 29 x 7 x CH_15 17th single nave 24 x 13 x CH_16 single nave 14 x 10 x x CH_17 17th single nave 28 x 18 x CH_18 14th single nave 39 x 13 x x x CH_19 12th 3 naves 19 x 13 x CH_20 single nave 9 x 6 x CH_21 single nave 11 x 6 CH_22 15th 3 naves 31 x 17 x CH_23 18th central plan 29 x 22 CH_24 18th single nave 5 x 9 x CH_25 single nave 17 x 8 CH_26 18th single nave 23 x 12 x CH_27 single nave 6 x 2 CH_28 16th single nave 21 x 8 CH_29 17th-18th 3 naves 22 x 13 CH_30 14th-15th single nave 34 x 10 x x CH_31 17th single nave 25 x 9 x x x CH_32 13th 3 naves 24 x 14 x CH_33 11th single nave 19 x 10 x x a Length (including presbytery and apse) and width in meters
20 CHAPTER 2 20 The large majority of the assets have a longitudinal plan with a single nave (23 assets) or three naves (7 assets), whereas only 3 buildings have a central plan. Churches and sanctuaries have areas ranging from approximately 50 m2 to 560 m2, whereas oratories, which are all characterized by a single nave, have areas ranging approximately from 150 m2 to 210 m2. All the chapels have a single nave and are small in size, with areas ranging approximately from 10 m2 to 70 m2. Table 3 also reports the interventions that, to the author’s knowledge, were performed in each church in the last 50 years. Reference is made to structural interventions (strengthening and/or geotechnical interventions), architectural restorations and floor refurbishment. It is interesting to observe that structural interventions and/or architectural restorations were performed in about half of the churches. Furthermore, floors were refurbished in 6 out of the 33 buildings inspected. The 33 churches under consideration are located in hilly and scarcely urbanized areas (Figure 2-6a). For each church, Figure 2-6b reports the slope section in the direction of the maximum gradient as obtained from DTM (Digital Terrain Model) data (Geoportale Regione Liguria 2020). For an easier comparison among the different slope sections, a zero-reference height equal to the minimum height above sea level in the considered section was assumed for each slope. It is observed that most of the churches are situated on slowly to moderately inclined slopes (average slope gradients smaller than 30°), whereas only three churches are located on steep slopes (average slope gradients equal or larger than 30°). From Figure 2-6b, it is also observed that one church is located at the top of a hill, whereas one is situated in a valley. Figure 2-6 Morphology of the Ligurian territory: a) hilly and scarcely urbanized areas, b) sections of the slopes where the churches under consideration are located (where Δh = h – hmin, being hmin the minimum height above sea level in the length (l) of the slope section considered for each church). 2.4. DAMAGE OF CHURCHES In this section, the damage observed in the 33 churches inspected is presented and critically analysed. As described by Ferrero et al. (2020), the additional churches experienced the same types of damage as the churches located on active landslides. For this reason, no distinction between them will be considered in the following paragraphs.
DAMAGE SURVEY OF HISTORIC MASONRY CHURCHES EXPOSED TO SLOW-MOVING LANDSLIDES 21 2.4.1. Damage survey The damage surveyed in the sample of churches is described below for the different structural elements composing the church: floors, walls and pillars, and arches and vaults. Damage in the floor appears in the form of cracking of tiles, gaps among tiles or sinking (Figure 2-7). Cracks are usually localized in few tiles and are especially observed on step treads and balustrades bases (Figure 2-7a). Conversely, gaps, which are separations that develop at the joints among tiles, are usually widespread in the floor (Figure 2-7b). In particular, several churches present a series of parallel gaps crossing the entire floor from one side to the other (Figure 2-7b). As shown in Figure 2-7c, in some cases cracks and gaps originate from the floor and propagate upwards into the walls. In addition to cracks and gaps, several churches exhibit sinking of floor, which is often accompanied by gaps among tiles or lifting of some of them, as shown in Figure 2-7d. Figure 2-7 Damage of floors: a) cracks on step treads and balustrades bases (CH_17), b) parallel gaps among tiles (CH_29), c) cracks propagating from floor to wall (CH_28), d) sinking of floors (CH_15). The majority of the churches present cracks in load-bearing masonry walls (Figure 2-8). Cracks are observed in the façade and apse walls as well as in lateral longitudinal and transverse walls. The cracks detected in the façade walls are mainly located next to openings and inside alcoves (Figure 2-8a). Lateral longitudinal walls usually exhibit cracks extending upwards from the base of the structure. Cracks are generally vertical and propagate along the entire height of the structure, in some cases continuing up into the vaults (Figure 2-8d). Significant diagonal cracks extending from the ground level are less frequently
22 CHAPTER 2 22 observed (Figure 2-8b). Some churches also exhibit vertical cracks that do not propagate from the floor. These cracks, which are generally repeated in each bay, progress over the entire height of the wall, increasing in width with height (Figure 2-8c), and continue up into arches and vaults, cutting them transversally. Finally, some churches present significant out-of-plumbness in lateral walls and pillars. In some cases, the entire building exhibits a rigid rotation, with both longitudinal walls leaning in the same direction (Figure 2-8e). Loss of horizontality of the metallic tie-rods is often observed in the case of rigid rotations (Figure 2-8e). Figure 2-8 Damage of walls: a) cracks in the façade wall next to openings (CH_3), b) diagonal cracks in longitudinal walls propagating from the level of the ground (CH_9), c) vertical cracks increasing in width with height at the middle span of the wall (CH_32), d) vertical cracks in lateral walls extending from the level of the ground and continuing up into vaults, e) rigid rotation producing out-of-plumbness of longitudinal walls and loss of horizontality of metallic tierods (CH_8). In most of the churches of the sample, widespread cracking and large deformations were surveyed in arches and vaults (Figure 2-9). A detailed description of this damage is provided in Section 2.5. As discussed
DAMAGE SURVEY OF HISTORIC MASONRY CHURCHES EXPOSED TO SLOW-MOVING LANDSLIDES 23 in further detail in Sections 2.4.2 and 2.5.2, it is interesting to observe that the vaults of several churches exhibit multiple parallel diagonal cracks, which are oriented in the same direction as the gaps of the floors. Figure 2-9 Damage in arches and vaults: a) widespread cracking (CH_32), b) large deformations (CH_13). 2.4.2. Critical damage assessment A critical damage assessment was performed based on the systematic observation of the damage experienced by the 33 churches under consideration. The main conclusions are reported below. For a full description of the results of the critical damage assessment, the reader is referred to Ferrero et al. (2020). The damage level was found to vary significantly across the 33 churches of the sample. In order to quantify its distribution, the churches were classified by the following five levels of increasing damage, which were defined using as a reference the European Macroseismic scale (EMS-98) for masonry buildings subjected to seismic actions (Grünthal 1998): (i) negligible to slight damage (grade 1), (ii) moderate damage (grade 2), (iii) substantial to heavy damage (grade 3), (iv) very heavy damage (grade 4), and (v) destruction (grade 5). The large majority of the churches (72.8% of the total) presented either slight or moderate damage, while 27.3% of the total suffered substantial to very heavy damage. Among these latter buildings, some were closed to public by order of local authorities due to safety reasons. It is important to note that the damage levels were assigned according to the damage surveyed during on-site inspections. Therefore, they might not reflect the damage experienced by the churches throughout their entire history. As reported in Section 2.3.3 and Table 3, interventions were performed in at least half of the buildings of the sample, with the result that part of the past damage could have been repaired or simply hidden. The large majority of the churches presented damage patterns congruent with the landslide direction, indicating that slow-moving landslides may induce significant damage to historic masonry churches. The congruence between damage and estimated landslide direction was evaluated by comparing the latter with an approximate damage direction, defined based on engineering judgment considering the crack pattern in plan as well as global rigid rotations (for an example see Figure 2-10). The damage was considered congruent with the landslide direction if the
24 CHAPTER 2 24 approximate damage direction was within the range between -45° and 45° compared to the landslide direction. Figure 2-10 shows two representative examples of crack patterns congruent with the landslide direction. It can be easily observed that the cracks affecting floors and vaults are characterized by a consistent orientation throughout the building. Furthermore, the cracks of the walls occur in planes oriented parallel to the direction of the cracks observed in floors and vaults. This allowed to identify a clear damage direction, which was found to be inclined by not more than ±45° with respect to the landslide direction. Congruence between damage pattern and landslide direction was also observed in the churches exhibiting a global rigid rotation. In these cases, the longitudinal walls, which were oriented almost perpendicular to the landslide, leaned in the direction of the landside, as expected. Figure 2-10 Damage patterns congruent with the estimated landslide direction: a) CH_29, b) CH_25. Four recurrent types of damage were identified in the churches inspected: (i) damage of floors, (ii) damage of walls, (iii) damage of arches and vaults, and (iv) rigid rotation. Figure 2-11 shows the occurrence of these types of damage, classified by damage grade, in the selected sample of churches. Note that the damage was classified according to the 5-level damage scale already adopted to estimate the global damage level. Damage of walls as well as damage of arches and vaults proved to be the most frequent types of damage. Damage of walls occurred in almost all the churches inspected (94% of the sample). Approximately 73% of the churches exhibited slight or moderate damage (grade 1 and 2), while 21.2% of them also presented heavy or very heavy damage (grade 3 and 4). Damage of arches and vaults was observed in the large majority of the churches (81.8% of the total). Damage of grade 1 or 2 occurred in 63.6% of the buildings, while damage of grade 3 or 4 was found in 18.2% of the sample. Damage of floors was also present in about half of the 33 churches inspected, whereas rigid rotations were observed only in few cases of single-nave churches of small size.
DAMAGE SURVEY OF HISTORIC MASONRY CHURCHES EXPOSED TO SLOW-MOVING LANDSLIDES 25 Figure 2-11 Recurrent types of damage classified by damage level. The damage induced to historic masonry churches by slow-moving landslides proved to be easily recognizable. Besides the identification of four recurrent types of damage, damage was not localized but widespread in the church. Cracks generally exhibited a consistent orientation throughout the building. The cracks patterns in the floors reflected the ones in the vaults. Furthermore, the cracks affecting the walls occurred in planes parallel to the orientation of the cracks observed in the floors and vaults. Churches were found to respond to slow-moving landslides with a global behaviour where the different structural components (i.e. walls, arches, vaults, etc.) contribute jointly to accommodate soil displacements. This behaviour is significantly different from the response by independent macroelements exhibited by churches under seismic actions. The following four global damage mechanism were identified: (i) hogging, (ii) shear deformation, (iii) global rigid rotation, and (iv) extension. As shown in Figure 2-12, each mechanism was associated to a specific soil displacement pattern produced by slow-moving landslides. The hogging, shear deformation, and global rigid rotation mechanisms were attributed to an incremental vertical ground movement, while the extension mechanism was associated to a horizontal ground movement. It is important to highlight that, since no quantitative information about the magnitude of the horizontal and vertical components of the landslide movements was generally available, the correlation between damage and soil displacements patterns was found through a critical interpretation of the surveyed crack patterns and deformation, which were used as indicators of ground movements (for further details, see Ferrero et al. 2021a). This allowed to determine if the dominant component of the landslide movements was vertical or horizontal. However, it should be recalled that landslides always involve a combination of downward and lateral ground movements (Cooper 2008); therefore, different mechanisms can occur together. Furthermore, the occurrence of a certain damage mechanism compared to the others may depend not only on the prevalent component of ground movement, but also on the direction of the landslide movement with respect to the church axes as well as on the church geometry and structural configuration.
26 CHAPTER 2 26 Figure 2-12 Global damage mechanism: a) Hogging, b) Shear deformation, c) Global rigid rotation, d) Extension. 2.5. DAMAGE OF ARCHES AND VAULTS As observed in the previous section, damage in arches and vaults was observed in most of the churches of the sample. In almost one fifth of the buildings, damage was classified as heavy or very heavy, indicating that these structural elements are sensitive to slow-moving landslides. 2.5.1. Cracks and deformations of masonry arches Damage in the arches appears in the form of cracks and deformations. Looking at Figure 2-13, which presents some examples of crack patterns, it is observed that some cracks are orthogonal to the arch external profile (Figure 2-13d-e-f-g-h), while others cut the arch diagonally and are often in continuity with the diagonal cracks observed in the vaults (Figure 2-13a-b-c). In the first case, the arch exhibits a bidimensional behaviour, while the second case points to the occurrence of transverse support movements. When cracks are orthogonal to the arch profile, the crack pattern can be either symmetrical or asymmetrical. In the case of symmetrical patterns, a crack occurs near the crown at the intrados (Figure 2-13d). When the crack configuration is asymmetrical, a recurrent crack pattern is more difficult to identify, as cracks appear at different locations along the arch profile in the different churches of the sample. Some examples of asymmetrical crack patterns are reported in Figure 2-13e-f-g-h. In Figure 2-13e, one cracks appears at the upper part of the arch, while some deterioration of the plaster is observed at the haunches, suggesting high levels of compressive stresses produced by the opening of two further cracks at the extrados. In Figure 2-13f, two cracks, very close one to each other, are detected at mid-span, while deterioration of the plaster is observed at one haunch only. In Figure 2-13g, two cracks appear, one located at mid-span and the other at one haunch, and deterioration of the plaster is observed in between them. In Figure 2-13h, only one crack, located at the left haunch, can be detected. Looking at Figure 2-13, it can also be observed that cracks are often continuous between arches and vaults, indicating an adequate connection between contiguous structural elements.
DAMAGE SURVEY OF HISTORIC MASONRY CHURCHES EXPOSED TO SLOW-MOVING LANDSLIDES 27 Figure 2-13 Cracks patterns observed in the arches (deterioration of the plaster indicated with a dotted line): a-b-c) diagonal cracks (CH_13, CH_22, CH_4), d) symmetrical crack pattern (CH_32), e-f-g-h) asymmetrical crack patterns (CH_4, CH_32, CH_29, CH_13).
34 CHAPTER 2 34 some cases, one single crack located close to mid-span is observed, while in other cases series of parallel cracks are detected. Diagonal cracks also frequently occur (Figure 2-20b). Figure 2-19 Typical cracks observed in cross vaults: a) crack along one of the diagonals (CH_22), b) parallel diagonal cracks (CH_22), c) diagonal cracks not passing through the keystone, d) longitudinal cracks. Figure 2-20 Typical cracks observed in barrel vaults: a) longitudinal cracks, b) diagonal cracks. As already described in Section 2.5.1, beside widespread cracking, vaults also exhibit large deformations. Representative examples for both cross and barrel vaults are presented in Figure 2-21.
DAMAGE SURVEY OF HISTORIC MASONRY CHURCHES EXPOSED TO SLOW-MOVING LANDSLIDES 35 Figure 2-21 Large deformations observed in cross vaults (a) and barrel vaults (b). Some recurrent damage patterns were identified by analysing the crack distribution across all the vaults of each church investigated. Several churches present diagonal cracks that are widespread throughout the building, all oriented in the same direction and parallel to the gaps observed in the floor. In several cases, these cracks originate from the level of the ground, cut the walls for their entire height, and continue up in arches and vaults. Some representative examples are reported in Figure 2-22. Ferrero et al. (2020) associated this crack pattern to the extension mechanism, which is produced by the horizontal component of the landslide movement. As shown in Figure 2-22, the cracks in the vaults as well as the gaps in the floor are oriented almost perpendicular to the direction of the slope movement. Furthermore, the cracks in the walls occur in planes perpendicular to the landslide direction. This indicates that the church experienced an extension in the landslide direction, suggesting that the damage observed in the vaults is mainly due to horizontal support displacements. Figure 2-22 Recurrent damage pattern observed in the vaults. Multiple diagonal cracks widespread throughout the building, all oriented in the same direction and parallel to the gaps of the floor: a) CH_ 22, b) CH_13. (Estimated landslide direction indicated with an arrow.)
36 CHAPTER 2 36 In some churches, the cracks of the vaults are repeated with the same pattern in almost all bays. A representative example is San Martino church in Cembrano (CH_32, Figure 2-23), where the vaults of the lateral naves are each affected by cracks that cut them transversally at the keystone (in the damage survey reported in Figure 2-23c see the cracks coloured in red). These cracks propagate from the walls and also affect the transverse arches separating the lateral and central naves (Figure 2-23a-b). Transverse cracks are also present in some vaults of the central nave. Since the cracks in the walls increase in width with height and do not propagate in the floor, this cracking pattern can be associated to a concave-upward bending (hogging) of the church produced by an incremental vertical ground movement in the direction of the longitudinal axis of the building (see Figure 2-12a). This indicates that arches and vaults were subjected to vertical support displacements. However, looking at the schematic representation of the hogging mechanism reported in Figure 2-12a, it is likely that the horizontal support displacements also occurred. Figure 2-23 Recurrent damage patterns of masonry vaults. Crack repeated with the same pattern in each bay (CH_32): a-b) cracks propagating from the walls and continuing up into arches and vaults, b) damage survey of the entire church (estimated landslide direction indicated with an arrow). The case of San Martino church in Cembrano is of particular interest because the church is located in an area affected by two slow-moving landslides acting in two different directions (see the arrows indicated in Figure 2-23), which produced a combination of two different global damage mechanisms. The landslide indicated as LD1 in Figure 2-23 was considered responsible of the hogging mechanism and corresponding
DAMAGE SURVEY OF HISTORIC MASONRY CHURCHES EXPOSED TO SLOW-MOVING LANDSLIDES 37 crack pattern described above (coloured in red in Figure 2-23). Conversely, the landslide named LD2 was found to produce an extension mechanism, which resulted in diagonal cracks in the vaults as well as parallel gaps in the floor, all oriented in the same direction (see the crack pattern coloured in blue in Figure 2-23). The occurrence of two different mechanisms, resulting from different soil displacements patterns, suggests that both vertical and horizontal displacements occurred at the supports of arches and vaults. Consequently, even if two different crack patterns were distinctly identified, it is not possible to exclude that the location at which cracks appeared was influenced by the combination of horizontal and vertical support displacements. 2.6. SUMMARY This chapter presented the results of the systematic damage survey performed on 33 historic masonry churches exposed to slow-moving landslides. Extensive and severe damage, congruent with the landslide direction, was observed in several churches of the sample. Since some buildings were even close to public due to safety reasons, it can be concluded that that slow-moving landslides pose a threat for the conservation of historic masonry churches. Due to the lack of detailed information about landslides movements, the damage assessment was performed through a critical interpretation of the surveyed crack patterns and deformation. This allowed to identify four global damage mechanisms associated to specific soil displacements patterns. After providing insights on the structural behaviour of the church in its entirety, attention was paid to arches and vaults. In several churches of the sample, widespread cracking and large deformations were observed, confirming that these structural elements are sensitive to slow-moving landslides. As expected, these phenomena were found to produce combinations of vertical and horizontal displacements at the abutments. However, in absence of information about the magnitude of support displacements, the damage assessment of arches and vaults was very challenging. If in the case of vaults some recurrent damage patterns were recognised, in the case of arches cracks appeared at different locations along the arch profile in the different churches of the sample. The damage interpretation was also further complicated by the impossibility of verifying the presence of cracks at the extrados, which was suggested by some deterioration of the plaster observed at the intrados. The critical analysis of the damaged surveyed demonstrated that, even in the cases where the predominant component of support displacements could be determined, the possibility that both vertical and horizontal displacements occurred prevented from identifying univocally the damage mechanism. In this respect, the observation of various different crack patterns in the arches suggests that the location at which cracks appear is strictly dependant on the way in which vertical and horizontal support displacements are combined. This clearly indicates the need for further investigation into the effects of combined vertical and horizontal support displacements on the response of masonry arches.
38 CHAPTER 2 38 REFERENCES ARPA Piemonte (Agenzia Regionale per la Protezione Ambientale). 2008. Linee guida all’interpretazione dei dati satellitari PSInsarTM in Piemonte. Cabella C. and G. L. Sacco. 2021. Studio degli effetti di una frana attiva su un edificio voltato: la chiesa di San Carlo Borromeo in Cassingheno (Genova). Master thesis, University of Genoa (in Italian). Cambiaggi L. 2020. Damage assessment of churches exposed to slope displacements in sliding areas. PhD diss., University of Genoa. Cascini L., Fornaro G. and D. Peduto. 2009. Analysis at medium scale of low-resolution DInSAR data in slow-moving landslide-affected areas. ISPRS Journal of Photogrammetry and Remote Sensing 64: 598- 611 Federici, P.R., F. Baldacci, A. Petresi, and A. Serani. 2001. Atlante dei Centri Abitati Instabili della Liguria. I. Provincia della Spezia (Atlas of the Unstable Inhabited Centres of Liguria. I. La Spezia province). Regione Liguria. Federici, P.R., M. Capitani, A. Chelli, N. Del Seppia, and A. Serani. 2004. Atlante dei Centri Abitati Instabili della Liguria. II. Provincia di Genova (Atlas of the Unstable Inhabited Centres of Liguria. II. Genova province). Regione Liguria. Federici, P.R., M. Capitani, A. Serani, and S. Stano. 2006. Atlante dei Centri Abitati Instabili della Liguria. III. Provincia di Savona (Atlas of the Unstable Inhabited Centres of Liguria. III. Savona province). Regione Liguria. Federici, P.R. and A. Chelli. 2007. Atlante dei Centri Abitati Instabili della Liguria. IV. Provincia di Imperia (Atlas of the Unstable Inhabited Centres of Liguria. IV. Imperia province). Regione Liguria. Ferrero C., L. Cambiaggi, R. Vecchiattini, and C. Calderini. 2020. Damage assessment of historic masonry churches exposed to slow-moving. International Journal of Architectural Heritage. Ferrero C., L. Cambiaggi, A. Fenialdi, P. Roca, R. Vecchiattini, and C. Calderini. 2021. Slow-moving landslide damage assessment of historic masonry churches: some case-studies in Italy. In SAHC 2021: 12th International Conference on Structural Analysis of Historical Constructions. Barcelona, Spain, September 2021 (Accepted). Geoportale Regione Liguria. Visualizzatore Cartografico. Accessed January 20, 2020. https://geoportal.regione.liguria.it Grünthal, G. 1998. European Macroseismic Scale 1998 (EMS-98), Cahiers du Centre Europèen de Gèodynamique et de Seismologie 15. Centre Europèen de Gèodynamique et de Seismologie, Luxembourg. G.U. no. 120, 25/05/1989 (suppl. ord. no. 38). Law no. 183 of 18/05/1989, Norme per il riassetto organizzativo e funzionale della difesa del suolo.
DAMAGE SURVEY OF HISTORIC MASONRY CHURCHES EXPOSED TO SLOW-MOVING LANDSLIDES 39 G.U. no. 45, 24/02/2004 (suppl. ord. no. 28). Legislative Decree no. 42 of 22/01/2004, Codice dei beni culturali e del paesaggio, ai sensi dell'articolo 10 della legge 6 luglio 2002, n. 137. Mamone A. 2017. Rilievo analisi e diagnosi del santuario di N.S. della Bastia in Busalla. Master thesis, University of Genoa (in Italian). Piano di Bacino Stralcio per l’Assetto Idrogeologico, Regione Liguria, 2017. Carte della Suscettività al Dissesto (Landslide Susceptibility Maps). Accessed October 25, 2018. http://www.pianidibacino.ambienteinliguria.it/. Piano Stralcio per l’Assetto Idrogeologico, Autorità di bacino distrettuale del fiume Po, 2017. Atlante dei Rischi Idraulici e Idrogeologici (Atlas of Hydraulic and Hydrogeological Risks). Accessed October 25, 2018. http://www.pai.adbpo.it/. QGIS 2017. Open Source Geographic Information System. Accessed May 3, 2018. https://qgis.org/en/site/. Regione Liguria e Segretariato Regionale del MiBACT per la Liguria. 2017. Vincoli architettonici, archeologici, paesaggistici. Accessed May 3, 2018. http://www.liguriavincoli.it/. Varnes, D. J. 1978. Slope movements and types of processes. In Landslides: Analysis and control, ed. R. L. Schuster and R. J. Krizek, Transportation Research Board, Special Report 176, 11-13. Washington, DC: National Academy of Sciences.
This page is intentionally left blank.
41 CHAPTER 3 3. LITERATURE REVIEW 3.1. INTRODUCTION This chapter presents the state-of-the-art of the research dealing with masonry arches and vaults on moving supports. The interest in the topic is rather recent, since the first systematic studies date back to the 2000s. As well described by DeJong (2016), the study of the response of masonry structures undergoing given settlements and, more in general, support displacements can be addressed from two different perspectives. On the one hand, it is needed to assess the stability under large displacements and deformations. On the other hand, it is necessary to predict minor damage and cracking which could affect the serviceability requirements of the structure. Nevertheless, in the case of arches and vaults, the large majority of the studies available in the literature were devoted to investigating the collapse of masonry arches and vaults due to different configurations of support displacements. On the contrary, much less attention was paid to predict cracking and define damage levels associated to a given value of support displacements. Regarding this second aspect, to the author’s knowledge, only Acikgoz et al. (2017) developed damage prediction maps, produced by using Limit Analysis (Heyman 1966), to correlate the damage states of a vaulted masonry structure to different scenarios of support displacements. In Section 3.2, the experimental investigations hitherto carried out to investigate the response of masonry arches and vaults on moving supports are presented. These studies were essential to gain an understanding of the mechanics of masonry arches and vaults undergoing large support displacements. For masonry arches, which are the main subject of this work, a detailed description of the damage and collapse mechanisms observed is provided. In the case of the vaults, whose structural behaviour is not investigated in this thesis, reference is only made to the existing literature. Sections 3.3.1 and 3.3.2 deal with the methods of structural analysis. Within the past two decades and especially in the last few years, a growing number of analytical and numerical procedures have been developed to investigate the stability of arches and vaults under support displacements. The large majority of these methods adopt the well-known assumptions on the behaviour of the masonry material that were firstly introduced by Heyman (1966, 1995) and provide the theoretical basis for the Limit Analysis theory. According to Heyman, the response of a masonry structure can be analysed considering that masonry has (i) infinite compressive strength, (ii) no tensile strength, and (iii) does not experience sliding failure. Under these hypotheses, masonry structures can be studied as assemblages of rigid blocks connected by no-tension interfaces. Since sliding cannot occur, the only way to deform is to open some cracks, which can be idealized as hinges. Stability thus becomes a matter of geometry rather than material strength (Heyman 1995).
42 CHAPTER 3 42 Starting from Heyman’s assumptions, some authors proposed analytical and computational methods based on a standard application of the Limit Analysis theorems (Sections 3.3.1), while others adopted modern and more complicated approaches such as finite element and discrete element modelling, among the others (Section 3.3.2). Many of these procedures were validated by comparison with the results of experimental tests performed on full-scale or small-scale models. In Sections 3.3.1 and 3.3.2, the capability of the different computational methods to predict the experimental response is evaluated. 3.2. EXPERIMENTAL INVESTIGATIONS Experimental tests have been widely used to investigate the stability of masonry arches and vaults under large support displacements. Table 4 and Table 5 collect all the experimental studies carried out so far on masonry arches and vaults, respectively. For each test, information is provided in terms of scale, dimension and material of the mockup, geometry of the structure investigated as well as type of support displacements imposed. In all the tests, support displacements were applied at low velocities in a static or quasi-static way. Table 4 Experimental investigations on masonry arches subjected to support displacements. Reference Scale Geometry Span length [cm] Voussoir material Joints Type of support displacements (Ochsendorf 2002, 2006) Small-scale Circular 39.0 Cast concrete Dry joints Outward horizontal Segmental 70.9 (Romano 2005; Romano and Ochsendorf 2010) Small-scale Circular 100.0 Cast concrete Dry joints Outward horizontal/ inward horizontal/ vertical Pointed (Smars 2000, 2010) Small-scale Circular 30.0 Stainless steel Dry joints Vertical/horizontal (Verstrynge et al. 2007) Small-scale Pointed 140 Brick Mortar joints Outward horizontal Parabolic (Zampieri et al. 2018a, 2018b, 2018c) 1:1 Segmental 228.1 Brick Mortar joints (with a plexiglass plate in the middle) Vertical/ inclined (45°) (Galassi et al. 2018) Small-scale Segmental 42.4/42.4/ 53.5 PVC Dry joints Outward horizontal/ vertical (Galassi et al. 2020) Small-scale Pointed 30.0/32.0/ 32.0/33.6/ 34.0/35.2 Autoclaved aerated concrete Dry joints Outward horizontal (Alforno et al. 2020) 1:6 Segmental 62.0 Wood Mortar joints Outward horizontal (Masciotta et al. 2020) Small-scale Segmental 190.0 Brick Mortar joints Outward horizontal
LITERATURE REVIEW 43 Table 5 Experimental investigations on masonry vaults subjected to support displacements. Reference Scale Geometry Span len g th [m] Block material Joints Type of support displacements (Ceradini 1996) 1:1 Cross vault 736.0 Brick Mortar joints Outward horizontal Sail vault 600.0 Tuff (Theodossopoulos 2001; Theodossopoulos et al. 2002) 1:4 Cross vault 127.5 (x 94.5) Wood Mortar joints Outward horizontal (Quinonez et al. 2010; Zessin et al. 2010) Small-scale Domes 32.9/29.5 3D printed Dry joints Outward horizontal (Shapiro 2012) Small-scale Barrel vaults 30.8/27.8 3D printed Dry joints Outward horizontal Cross vault 27.8 (Van Mele et al. 2012) Small-scale Cross vault 30.0 3D printed Dry joints Horizontal (outward transverse and diagonal) /vertical (Rossi et al. 2016, Milani et al. 2016) 1:5 Cross vault 62.0 3D printed Dry joints Horizontal (outward transverse and diagonal) /vertical (Rossi et al. 2017) 1:10 Pavilion vault 34.3 3D printed Dry joints Outward horizontal (Calvo Barentin et al. 2017) Small-scale Cross vault 30.0 3D p rinte d Dry joints Horizontal/vertical (Foti et al. 2018) Small-scale Cross vault 100.0 3D printed Dry joints Horizontal (outward transverse and diagonal) /vertical (D’Altri et. 2020) 1/12 Pointed barrel vault 50.8 Wood Mortar joints Linear vertical along one edge (Torres et al. 2019a) 1:1 Timbrel cross vault 360 Brick Mortar joints Vertical (Torres et al. 2019b) 1:1 Timbrel cross vault 360 Brick Mortar joints Up-and-down cyclical Looking at Table 4 and Table 5, it is observed that the large majority of the experimental tests were performed on small-scale models, while only a small number of works proposed full-scale models. This is not surprising, since full-scale model testing requires significant building skills and, furthermore, it is associated with high costs and long times for fabricating the mockup. Among all the tests performed on arches, only Zampieri et al. (2018a, 2018b, 2018c) analysed a full-scale arch, which was tested to collapse due to vertical and inclined support displacements (Figure 3-1a). Full-scale vaults were built only by Ceradini (1996) and Torres et al. (2019a, 2019b). In Ceradini (1996), the response of two masonry vaults (sail and cross vaults) to horizontal support displacements was investigated, whereas in Torres et al. (2019a, 2019b) a full-scale timbrel vault was tested under vertical and up-and-down cyclic displacements of one support (Figure 3-1b). On the contrary, small-scale testing is less expensive, allows to repeat several trials for the same test and can be easily used to investigate structures with different geometries. A representative
50 CHAPTER 3 50 In the case of inclined support displacements, the only experimental test performed in the literature (Zampieri et al. 2018b, 2018c) showed a collapse mechanism due to the alignment of the three initial hinges (Figure 3-8). Figure 3-8 Collapse mechanism for a segmental arch subjected to an inclined (45° with respect to the horizontal) displacement of one support (Zampieri et al. 2018b). 3.3. COMPUTATIONAL METHODS 3.3.1. Analytical and computational methods based on Limit Analysis Analytical and computational methods based on the Limit Analysis theory have been used to predict collapse due to support displacements mainly for masonry arches and bi-dimensional structures (e.g. buttressed arches), since their application to three-dimensional structures (e.g. pavilion or cross vaults) is hardly feasible. Some approaches based on Limit Analysis have been developed in the last decades to assess the stability of three-dimensional structures under gravitational or point loading, such as the funicular analysis of masonry vaults by O’Dwyer (1999) or the Thrust Network Analysis by Block (2009) and Block and Ochsendorf (2007, 2009), among others. However, these methods analyse the structure in its undeformed configuration and do not accommodate large support displacements, which, on the contrary, involve significant geometrical deformations. It is well-known that, under the simplified assumptions on the behaviour of the masonry material introduced by Heyman, the limit theorems of plasticity can be applied to masonry structures (Heyman 1966; Roca 2010). The lower-bound and upper-bound theorems provide the basis for the so-called static and kinematic approaches, respectively (Roca 2010). According to the lower-bound (safe) theorem, a structure is safe if at least one thrust line which is in equilibrium with the external loads and falls with the boundaries of the structure can be found. The dual approach of the safe theorem is the upper-bound theorem, which states that collapse occurs if a kinetically admissible mechanism for which the work done by the external forces is positive or zero can be found. In addition to the above-mentioned theorems, the uniqueness theorem is also applicable: a limit condition (i.e. the structure is on the point to collapse) is reached if a both statically and kinematically admissible collapsing mechanism can be found. This is tantamount to state that collapse occurs when the thrust line touches the arch boundary in as many points (corresponding to hinges) as needed to activate a mechanism. Under these conditions, the mechanism is the true ultimate mechanism, and the thrust line is unique (Heyman 1966, Roca 2010).
LITERATURE REVIEW 51 Several studies adopted the static or kinematic approach of Limit Analysis to identify the position of the three hinges that open as soon as supports move as well as to predict the ultimate displacement capacity and collapse mechanisms for rigid no-tension arches with different geometries. As stated by Ochsendorf 2006, an initial equilibrium configuration, identified by the opening of three hinges, must be necessarily known to determine the collapse state. The first problem can be addressed by studying the arch in its undeformed configuration under the assumption of small (infinitesimal) displacements usually adopted in Limit Analysis. On the contrary, as observed in the experimental tests, the second problem involves progressive changes in the geometry and must be analysed in the framework of large displacements using iterative procedures able to follow the evolution of the arch deformed configuration with the increase of support displacements. Within the framework of small displacements, reference should be made to the theory of the incipient settled states developed by Como (1996, 1998, 2016). In the undeformed configuration, the position of the three initial hinges that open when an infinitesimal movement of the abutments occurs can be found using the static and kinematic theorems of the minimum thrust. According to these theorems, the thrust (i.e. the horizontal reaction of the moving support) is the lowest of all the statically admissible thrusts and the highest of the kinematically admissible ones. A trust is statically admissible when the thrust line lies within the profile of the arch, while it is kinematically admissible if the internal work done for a kinematically admissible virtual mechanism is equal to zero (Coccia et al. 2015). According to the uniqueness theorem, the actual thrust is unique and is the only one being both statically and kinematically admissible. The first examples of application of the Limit Analysis theory to rigid-block arches on moving supports in the framework of large displacements can be found in Smars (2000, 2010) and Ochsendorf (2002, 2006). Smars (2000, 2010) identified the domain of statically and kinematically admissible movements for a chosen mechanism in a circular voussoir arch. Since the arch is stable only if the thrust line is fully inside the arch boundaries, the statically admissible domain of a mechanism was defined as the subset of the kinematic domain for which this condition can be accomplished. Smars (2000, 2010) also highlighted that a transition between different mechanisms can occur as the arch deforms, since hinges can close and open at another position along the arch profile. Figure 3-9 Stability domain of a circular arch subjected to large support displacements (Smars 2010).
52 CHAPTER 3 52 Ochsendorf (2002, 2006) developed an iterative procedure, based on the thrust line analysis, to compute the collapse displacement and corresponding horizontal thrust for circular rigid-block arches on horizontal spreading supports. The possibility that hinges move with the increase of support displacements was also considered. The algorithm proposed by Ochsendorf, which was implemented in a MATLAB code, is presented in Figure 3-10. First, the location of the three hinges opening for a small outward movement of the abutments and the corresponding minimum thrust are determined considering the arch undeformed geometry. Once an initial equilibrium configuration is known, support displacements are gradually increased, and the equilibrium state of the structure as it deforms until collapse is followed. At each displacement increment, the geometry of the arch is updated, a new thrust line computed, and a check on possible changes in the hinge location performed. Figure 3-10 – Thrust line analysis-based iterative procedure to study the collapse state of rigid-block circular arches on horizontal spreading supports (Ochsendorf 2002, 2006).
LITERATURE REVIEW 53 The analytical predictions were compared to the experimental results from small-scale models testing (see Section 3.2). Although the theoretical procedure slightly overestimated the experimental displacement capacity, a good agreement was obtained in terms of both collapse mechanism and hinge position. As expected, differently from the experimental tests, where collapse involved the opening of only four hinges due to the slight asymmetry of the physical models, the predicted failure mode was a symmetrical fivehinge mechanism with hinges occurring at both supports. The difference between predicted and experimental displacement capacity was attributed to the imperfections of the experimental models. The studies by Ochsendorf provided indications of the values of the horizontal thrust and span increase at collapse for arches with different geometries and numbers of voussoirs. Ochsendorf also demonstrated that the horizontal thrust transmitted by the arch substantially increases with the increase of support displacements due to the changes in the arch geometry as well as hinge movement. Romano (2005) and Romano and Ochsendorf (2010) adopted the same procedure proposed in Ochsendorf (2002, 2006) to investigate the collapse of circular and pointed arches with varying geometries on horizontal spreading supports. Graphical analyses were also performed to extend the study to different configurations of support displacements, such as closing supports and vertical displacement of one support. The numerical and graphical predictions well compared with the results from small-scale model testing (see Section 3.2) in terms of collapse mechanism and hinge location. However, as already observed by Ochsendorf (2002, 2006), they generally overestimated the displacement capacity. An important result obtained from these studies is that pointed arches exhibit a significantly larger displacement capacity with respect to circular arches with the same inner span. A further application of the thrust line analysis to study masonry arches on moving supports can be found in McInerney and DeJong (2015), where a two-dimensional analytical model based on thrust line analysis was developed to predict the ultimate displacement capacity of circular and pointed arches subjected to vertical and horizontal support displacements. After assuming an initial location of the three hinges occurring when one support moves, support displacements were gradually increased up to failure. Due to the need to consider continuous changes in the geometry, the maximum displacement prior to collapse was determined by iteratively solving the equilibrium equations in MATLAB. The analytical predictions were compared to numerical results from DE modelling (see Section 3.3.2). An interesting analytical tool combining the use of kinematic and static analyses was proposed by Block et al. (2006) to evaluate the effect of large support displacements on the stability of vaulted masonry buildings. Several possible collapse mechanisms can be investigated in real-time thanks to the use of interactive graphic analysis, geometrically controlled loads, and animated kinematics. Different configurations of support displacements, including combinations of vertical and horizontal displacements, can also be simulated. However, an important limitation is that the possibility that hinges change location as support displacements increase is not automatically implemented. Furthermore, although conservative solutions can be provided for three-dimensional problems by using the slicing technique, the tool is mainly addressed to bi-dimensional structures. More recently, Coccia et al. (2015) investigated the collapse of circular arches on horizontal spreading supports by using the kinematic approach of Limit Analysis. An iterative tool, similar to that proposed by Ochsendorf (2002, 2006), was developed to compute the ultimate displacement and corresponding
54 CHAPTER 3 54 horizontal thrust. Simplified analytical formulations calibrated on the basis of the proposed model were also suggested. The kinematic approach was applied first in the arch undeformed configuration, calculating the position of the three initial hinges through the kinematic theorem of the minimum thrust proposed by Como (1996, 1998, 2016), and then in the deformed configuration increasing support displacements up to collapse. The possibility that hinges move as support displacements increase was also considered. The procedure proposed by Coccia et al. (2015) was validated through comparison with the results of the experimental tests performed by Ochsendorf (2002, 2006). Di Carlo and Coccia (2020) adopted the procedure illustrated in Coccia et al. (2015) to analyse the stability of elliptical rigid-block arches on horizontal spreading supports. An innovative aspect of this work lies in the introduction of a safety check on the possible activation of sliding phenomena between blocks. For this purpose, at each displacement increment, the shear force at the joints was compared to the shear strength calculated according to a Mohr-Coulomb law with zero or finite cohesion. An interesting outcome is that neglecting sliding phenomena in elliptical arches may not lead to conservative results. Indeed, the values of displacement obtained considering the attainment of the shear strength with finite cohesion were always lower than the collapse displacements evaluated by using the kinematic approach only. Figure 3-11 Application of the kinematic approach to study the stability of elliptical arches on horizontal spreading supports (Di Carlo and Coccia 2020). Di Carlo et al. (2018) extended the procedure proposed in Coccia et al. (2015) to evaluate the collapse load of a circular arch undergoing a finite horizontal displacement of the springings. The approach is innovative, since the effect of large support displacements on the capacity of masonry arches to sustain point loads is still rather unexplored. An incremental vertical point load was applied at the crown of the arch as support displacements increased. The collapse load was calculated in the arch deformed configuration using the kinematic approach. The possibility of hinge movement was also taken into account. Very recently, Zampieri et al. (2018a) developed an analytical procedure to identify the position of the three initial hinges that occur in circular continuous arches subjected to vertical, horizontal and inclined displacements of one support. To univocally determine hinge location, both the static and kinematic theorems of Limit Analysis were applied in the arch undeformed configuration. A key finding is that the initial hinge configuration varies according to the direction of the imposed support displacements. The analytical predictions were compared to the results from experimental tests and FE micro-modelling for the
LITERATURE REVIEW 55 case of a segmental arch subjected to vertical and inclined (45° with respect to the horizontal) displacements of one support. The proposed analytical approach was found capable to simulate the experimental response, though some differences in terms of hinge location were obtained. The same procedure proposed in Zampieri et al. (2018a) was adopted in Zampieri et al. (2019) to analyse an arch-pillar system. In Zampieri et al. (2018b), the methodology was extended in the framework of large displacements to investigate the collapse state of masonry arches subjected to inclined support displacements. The Principle of Virtual Work, in combination with thrust line analysis, was iteratively applied to the arch deformed configuration until reaching collapse. The proposed procedure was used to simulate the experimental test carried out on a full-scale segmental arch subjected to an inclined (45° with respect to the horizontal) displacement of one support. Despite some discrepancies in terms of hinge location, the numerical procedure well captured the experimental evidence in terms of collapse mechanism. However, this procedure had an important limitation, as it assumed that collapse could occur only by the alignment of the three initial hinges. In Zampieri et al. (2018c), an incremental procedure using both the Principle of Virtual Work and the limit equilibrium approach was proposed to investigate different configurations of support displacements in circular and segmental arches in the large displacement regime. A probabilistic approach was also introduced to consider the effects of geometrical uncertainties on the arch response. The developed methodology was applied to simulate two experimental tests on masonry arches on moving supports. The results demonstrated that including geometrical uncertainties provides a better estimate of the experimental displacement capacity, which, on the contrary, is generally overestimated when using the nominal geometry. 3.3.2. Modern computational methods The two last decades have witnessed a continuous development of numerical methods and computational tools that assess the stability of masonry arches and vaults on moving supports going beyond the standard application of the theorems of Limit Analysis. Nevertheless, the large majority of these methods have still adopted Heyman’s assumptions on the behaviour of masonry material, with the results that arches and vaults have been generally modelled as assemblages of (rigid) blocks interacting at no-tension joints. Discrete element (DE) and finite element (FE) methods have been widely used in the framework of large displacements. Differently from the methods based on Limit Analysis, they are not limited to the study of arches and bi-dimensional structures and can also be applied to three-dimensional structures. The DE method was first developed for rock mechanics (Cundall 1971) and subsequently applied to masonry structures (e.g., Lemos 1997, 2007). In DEM, masonry is modelled as a discontinuous material where blocks are treated as separate bodies (usually rigid or quasi-rigid) interacting by contact interfaces. Differently from FEM, DEM offers the possibility of simulating large relative movements and even full separation between the units (Lemos 2007; McInerney and DeJong 2015). For this reason, it is considered particularly suitable to investigate failure modes due to loss of stability and progressive changes in the geometry, like the ones observed in arches and vaults. DE models can also be easily used to analyse a wide variety of geometries. An interesting example can be found in McInerney and DeJong (2015), where the response of masonry cross vaults and arches with
56 CHAPTER 3 56 several different geometries was investigated under horizontal and vertical support displacements. Masonry units were assumed as rigid, while a Mohr Coulomb model was adopted for the joint contacts. In order to simulate the slow development of settlement phenomena, support displacements were applied in a quasistatic way thanks to the use of adaptive global damping. One of the main findings of the work was that both groin vaults and arches exhibited a significantly larger capacity to sustain vertical support displacements compared to horizontal displacements. Furthermore, for several of the geometries investigated, the displacement capacity of the groin vaults could be roughly estimated from the capacity of arches with similar geometries. The numerical results in terms of collapse displacement were also found to be in good agreement with the analytical predictions from a bi-dimensional model based on thrust line analysis (see Section 3.3.1). Despite these achievements, the adopted modelling approach presented some limitations: localized crushing of material at the joints was not considered and, furthermore, results were not fully repeatable when sliding between blocks was significant. Figure 3-12 Comparison between DEM and 2D thrust line analysis to investigate the stability of groin vaults and arches with varying geometries under horizontal and vertical support displacements (McInerney and DeJong 2015). In Lengyel (2017) and Lengyel and Bagi (2016), the response of pointed vaults was analysed using DEM. Lengyel (2017) investigated the structural behaviour of pointed barrel and cross vaults subjected to selfweight and finite horizontal support displacements. The main aim of the work was to evaluate if the pointed shape improved the performance of the vaults with respect to a circular centreline. The numerical models were created using the three-dimensional DEM software 3DEC, which is based on the compliant contact formulation of Cundall and Strack (1979). The elastic deformability of the block was also taken into consideration in the DE modelling. Lengyel and Bagi (2016) evaluated the magnitude of the horizontal thrust transmitted by pointed barrel vaults subjected to increasing outward support displacements. Further applications of DEM to study the collapse of masonry cross vaults under large support displacements can be found in Foti et al. (2018) and Van Mele et al. (2012). In both studies, the cross vaults
LITERATURE REVIEW 57 were modelled as assemblages of rigid blocks using 3DEC. Horizontal (transverse and diagonal) and vertical displacements were applied at one support of the vault in a quasi-static way to simulate the evolution of the settlement process as well as to enable the structure to recover the static equilibrium after each displacement increment. In Foti et al. (2018), the effect of different block arrangements on the vault performance was also evaluated, demonstrating that the masonry pattern can affect both collapse mechanism and ultimate displacement capacity. In both the above-mentioned studies, the numerical predictions were compared to the results from experimental tests on 3D-printed small-scale models. This comparison showed that the imperfections of the physical models could significantly affect the response in term of displacement capacity and collapse mechanism. Although for some directions of imposed displacements the DE models were able to well capture the experimental failure mode (Figure 3-13a), in other cases the predicted mechanism was different from the one observed in the physical model (Figure 3-13b). Furthermore, the numerical simulations generally significantly overpredicted the displacements capacities obtained in the experimental tests. a) b) Figure 3-13 Comparison of collapse mechanisms obtained from experimental tests (left) and DEM (right) for a masonry cross vault subjected to the diagonal (a) and transverse (b) displacement of one support (Van Mele et al. 2012) .
58 CHAPTER 3 58 Very recently, Dell’Endice et al. (2021) proposed a new method to simulate imperfections within the DEM framework. In particular, the effect of the mechanical and geometrical imperfections on the structural behaviour of a pavilion vault on horizontal spreading supports was investigated. The results from DE analyses, performed first considering a perfect digital model geometry and then including imperfections, were compared to the results from small-scale model testing. Material and geometric imperfections were found to affect both the load path within the vault and the displacement capacity. A parametric analysis demonstrated that the collapse mechanism did not change for a small amount of imperfections, even though the internal flow path was significantly different. On the contrary, for increasing amount of imperfections, the maximum allowable displacement and the collapse mechanism could drastically change, leading to a different structural behaviour of the masonry vault. The simulation of mechanical imperfections allowed to better capture the crack pattern observed in the experimental tests. FE methods can also be used to investigate the stability of masonry arches and vaults on moving supports. Nevertheless, geometrical nonlinearities must be properly modelled to consider the significant changes in the geometry. Furthermore, FE models have the drawback of becoming computationally demanding and very time consuming, especially when including interface or contact elements and dealing with large complicated structures. For these reasons, the use of FEM to study the collapse of masonry arches and vaults on moving supports is still very limited. Most of the applications of FEM to masonry arches are based on a micro-modelling approach. Ayensa et al. (2015) proposed a discontinuous FE model to evaluate the effect of soil settlement on the stability of a portal frame (i.e. an arch supported on two piers) of an historic Romanesque church. Zampieri et al. (2018a) studied the response of a segmental arch to vertical and inclined support displacements by using a FE micro-model, in which the arch was built as a set of linear elastic blocks connected by non-linear 1D point-contact elements. The results were compared with experimental and analytical predictions, showing good agreement. Very recently, Alforno et al. (2020) proposed a simplified FE micro-modelling approach, implemented in the commercial FEM software Abaqus, to study the static behaviour of masonry arches and vaults subjected to external forces and large support displacements. The numerical models were built as assemblages of linear elastic voussoirs interacting at nonlinear interfaces with zero tensile strength. The interfaces were assumed to be almost rigid in compression, with the result that all the elastic deformability of the assemblage was concentrated in the blocks. For this reason, the Young’s modulus adopted for the voussoirs was not taken equal to the Young’s modulus of the blocks, but it was defined considering the contribution of both blocks and interfaces. The proposed approach can be used for structures with both dry joints and mortar joints with low cohesion. In this latter case, the geometry of the voussoirs is enlarged by the half of the thickness of the mortar joint, and the deformability of the mortar is taken into account through the Young’s modulus of the expanded block. The numerical modelling strategy was validated through comparison with experimental tests on small-scale models of a circular arch, made of wooden voussoirs bonded by mortar, on spreading supports and a 3D-printed dry-joint cross vault subjected to different configurations of horizontal support displacements.
LITERATURE REVIEW 59 u x = 17.2 m m u x = 35.0 m m u x = 36.3 m m Figure 3-14 FE micro-modelling of a dry-joint masonry cross vault subjected to an increasing horizontal support displacement ux: evolution of the damage configuration (Alforno et al. 2020). Differently from the micro-modelling approaches described above, Masciotta et al. (2020) investigated the dynamic behaviour of a segmental masonry arch subjected to increasing horizontal support displacements using a non-commercial FE code which modelled masonry as a nonlinear elastic isotropic material with zero or weak tensile strength and infinite or bounded compressive strength. Few examples of application of FE methods to masonry vaults subjected to large support displacements can be found in the literature. Theodossopoulos (2001) and Theodossopoulos et al. (2002) used FE macro- and micro-models (created in Abaqus) to better understand the results of the experimental tests carried out on a small-scale cross vault subjected to horizontal support displacements. Both material and geometrical nonlinearities were considered in the FE simulations. In Torres et al. (2019a, 2019b), 3D elastic finite element models, created in the commercial software Abaqus and Lusas, were used for the preliminary assessment of a timbrel cross vault subjected to vertical support displacements. The results of the FE simulations helped in properly designing the experimental tests on the full-scale masonry vault. D’Altri et al. (2020) developed a 3D non-standard contact-based distinct blocks model, implemented in Abaqus, to simulate the experimental tests carried out on a small-scale pointed barrel vault subjected to a non-uniform vertical displacement along one edge. The presence of mortar joints in the small-scale model was taken into consideration in the numerical model by means of expanded blocks, which were assembled by zerothickness contact-based interfaces. The comparison between numerical and experimental results showed a good agreement in terms of crack pattern and deformation profiles. The numerical model was then used to simulate different configurations of uniform and non-uniform support displacements.
66 CHAPTER 3 66 Lemos, J. V. 1997. Discrete element modelling of the seismic behavior of stone masonry arches. In: Proceedings of the 4th International Symposium Computer Methods in Structural Masonry, ed. J. Middleton and G. Pande. Swansea, UK: Books & Journals International. Lemos, J. V. 2007. Discrete element modeling of masonry structures. International Journal of Architectural Heritage 1(2): 190-213. Lengyel, G. 2017. Discrete element analysis of gothic masonry vaults for self-weight and horizontal support displacement. Engineering Structures 148:195–209. http://dx.doi.org/10.1016/j.engstruct.2017.06.014. Lengyel, G. and K. Bagi. 2016. Horizontal reaction components of pointed vaults. International Journal of Masonry Research and Innovation 1(4): 398–420. Masciotta, M. G., D. Pellegrini, M. Girardi, C, Padovani, A. Barontini, P.B. Lourenço, D. Brigante, and G. Fabbrocino. 2020. Dynamic characterization of progressively damaged segmental masonry arches with one settled support: experimental and numerical analyses. Frattura ed Integrità Strutturale 51: 423-41. McInerney, J., and M. J. DeJong. 2015. Discrete element modeling of groin vault displacement capacity. International Journal of Architectural Heritage 9(8): 1037-49. http://dx.doi.org/10.1080/15583058.2014.923953 Milani, G., M. Rossi, C. Calderini, and S. Lagomarsino. 2016. Tilting plane tests on a small-scale masonry cross vault: experimental results and numerical simulations through a heterogeneous approach. Engineering Structures 123: 300-312. http://dx.doi.org/10.1016/j.engstruct.2016.05.017. Misseri, G., M. J. DeJong, and L. Rovero. 2018. Experimental and numerical investigation of the collapse of pointed masonry arches under quasi-static horizontal loading. Engineering Structures 173: 180-90. https://doi.org/10.1016/j.engstruct.2018.06.009. O’Dwyer, D. 1999. Funicular analysis of masonry vaults. Computers and Structures 73: 187–97. Ochsendorf, J. A. 2002. Collapse of masonry structures. PhD diss., University of Cambridge. Ochsendorf, J. A. 2006. The masonry arch on spreading supports. Structural Engineer 84(2): 29–35. Pippard A.J.S. and R. Ashby. 1939. An experimental study of the voussoir arch. Journal of the Institution of Civil Engineers 10(3): 383-404. Portioli, F., and L. Cascini. 2017. Large displacement analysis of dry-jointed masonry structures subjected to settlements using rigid block modelling. Engineering Structures 148: 485–96. Quinonez, A., J. Zessin, A. Nutzel, and J. A. Ochsendorf. 2010. Small-scale models for testing masonry structures. Advanced Materials Research 133-134: 497–502. Roca, P., M. Cervera, G. Gariup, and L. Pelà. 2010. Structural analysis of masonry historical constructions. classical and advanced approaches. Archives of Computational Methods in Engineering 17(3): 299– 325. Romano, A. 2005. Modelling, analysis and testing of masonry structures. PhD diss., University of Naples Federico II.
LITERATURE REVIEW 67 Romano, A., and J. A.Ochsendorf. 2010. The mechanics of gothic masonry arches. International Journal of Architectural Heritage 4(1): 59–82. http://dx.doi.org/10.1080/15583050902914660 Rossi, M., C. Calderini, and S. Lagomarsino. 2016. Experimental testing of the seismic in-plane displacement capacity of masonry cross vaults through a scale model. Bulletin of Earthquake Engineering 14(1): 261–81. Rossi, M., C. Calvo Barentin, T. Van Mele, and P. Block. 2017. Experimental study on the behaviour of masonry pavilion vaults on spreading supports. Structures 11: 110-20. http://dx.doi.org/10.1016/j.istruc.2017.04.008. Shapiro, E.E. 2012. Collapse mechanisms of small-scale unreinforced masonry vaults. Master thesis, Massachusetts Institute of Technology. Smars, P. 2000. Sur La Stabilité Des arcs et voutes. PhD diss., Catholic University of Leuven. Smars, P. 2010. Kinematic stability of masonry arches. Advanced Materials Research 133–134: 429-34. Theodossopoulos D. 2001. Structural behaviour of historic masonry cross vaults. PhD diss., University of Edinburgh. Theodossopoulos, D., B. P. Sinha, A. S. Usmani, and A. J. Macdonald. 2002. Assessment of the structural response of masonry cross vaults. Strain 38(3): 119–27. Torres, B., E. Bertolesi, P. A. Calderón, J. J. Moragues, and J. M. Adam. 2019a. Experimental investigation of a full-scale timbrel masonry cross vault subjected to vertical settlement. Construction and Building Materials 221: 421–32. https://doi.org/10.1016/j.conbuildmat.2019.06.015. Torres, B., E. Bertolesi, P. A. Calderón, J. J. Moragues, and J. M. Adam. 2019b. A full-scale timbrel cross vault subjected to vertical cyclical displacements in one of its supports. Engineering Structures 183: 791-804. https://doi.org/10.1016/j.engstruct.2019.01.054. Tralli, A., A. Chiozzi, N. Grillanda, and G. Milani. 2020. Masonry structures in the presence of foundation settlements and unilateral contact problems. International Journal of Solids and Structures 191-192: 187–201. Van Mele, T., J. McInerney, M. J. DeJong, and P. Block. 2012. Physical and computational discrete modelling of masonry vault collapse. In SAHC2012: Proceedings of 8th International Conference on Structural Analysis of Historical Constructions, ed. J. Jasienko, 2552–2560. Dolnośląskie Wydawnictwo Edukacyjne. Verstrynge, E, L. Schueremans, P. Smars, and D. Van Gemert. 2007. Design and testing of masonry arches: a project of bachelor students in civil engineering. In ARCH’07: Proceedings of the International Conference on Arch Bridges 351-358, ed. P. B. Lourenço, D. V. Oliveira and A. Portela. Guimarães: University of Minho, Department of Civil Engineering. Zampieri, P., F. Faleschini, M. A. Zanini, and N. Simoncello. 2018a. Collapse mechanisms of masonry arches with settled springing. Engineering Structures 156: 363–74. doi:10.1016/j. engstruct.2017.11.048.
68 CHAPTER 3 68 Zampieri, P., M. Amoroso, and C. Pellegrino. 2019. The masonry buttressed arch on spreading support. Structures 20: 226–36. https://doi.org/10.1016/j.istruc.2019.03.008. Zampieri, P., N. Cavalagli, V. Gusella, and C. Pellegrino. 2018c. Collapse displacements of masonry arch with geometrical uncertainties on spreading supports. Computers and Structures 208: 118–29. https://doi.org/10.1016/j.compstruc.2018.07.001. Zampieri, P., N. Simoncello, and C. Pellegrino. 2018b. Structural behaviour of masonry arch with nohorizontal springing settlement. Frattura ed Integrità Strutturale 12(43): 182–90. Zessin, J., W. Lau, and J. A. Ochsendorf. 2010. Equilibrium of Cracked Masonry Domes. Proceedings of the Institution of Civil Engineers: Engineering and Computational Mechanics 163(EM3): 135–45.
69 CHAPTER 4 4. NUMERICAL PREDICTIONS FOR A RIGID-NO TENSION ARCH 1 4.1. INTRODUCTION As explained in Chapter 1, the methodology proposed in the research to investigate the response of masonry arches to inclined support displacements included both experimental and numerical analyses on a segmental small-scale dry-joint masonry arch. Prior to performing the experimental tests, some numerical simulations were carried out for the preliminary assessment of the arch behaviour when subjected to different combinations of horizontal and vertical support displacements. Since the response of masonry arches to inclined support displacements has never been systematically investigated in the literature (see Chapter 3), these analyses were aimed at identifying the expected collapse mechanisms and determining the corresponding ultimate displacement capacity. These information were essential for the design of the experimental set-up. The arch behaviour was analysed in the framework of large displacements using, to improve the robustness of the results, two different numerical approaches, namely finite element (FE) modelling and rigid block (RB) modelling (Section 4.2). Both approaches were based on a micro-modelling strategy, in which the arch was discretized as an assemblage of voussoirs, very stiff and infinitely resistant in compression in the FEM and rigid in the RBM, interacting at no-tension friction interfaces. The choice to adopt this modelling strategy was based on two main reasons: on one hand, it complied with Heymans’ assumptions on the behaviour of the masonry material, and on other hand it was particular suitable to simulate the response of the small-scale arch tested in the experiments. Indeed, each block of the numerical models represented a voussoir of the mock-up, and the no-tension friction interfaces simulated the dryjoints. The adopted numerical approaches were first validated against experimental results from literature (Section 4.3) and were then used to investigate the response of the segmental arch under study to different configurations of support displacements (Section 4.4). The effect of the displacement direction on the arch performance was evaluated in terms of initial hinge position, collapse mechanism, support reactiondisplacements curves as well as ultimate displacement capacity and support reactions at collapse. The sensitivity of the results to the number of voussoirs was also investigated (Section 4.5). 1 This chapter is based on Ferrero et al. (2021b)
70 CHAPTER 4 70 4.2. NUMERICAL MODELLING This section presents the two numerical approaches, based on a micro-modelling strategy (Figure 4-1), used in this thesis to investigate the response of dry-joint masonry arches to large support movements. FE and RB models were prepared for the small-scale arches tested in the literature and used for validation (Section 4.3) as well as for the segmental arch investigated in this research (Section 4.4). In all the arches analysed, one support was fixed, while the other was subjected to an imposed displacement , whose direction was identified with the angle measured from the vertical (Figure 4-1). The horizontal and vertical components of the imposed displacement , indicated respectively as x and z (Figure 4-1), were expressed in a dimensionless form as span increase x/L and deflection ratio z/L, where L is the span length of the arch (Figure 4-1). Figure 4-1 Micro-modelling strategy and application of support displacements. 4.2.1. Finite element modelling FE analyses were performed using the commercial FEM software DIANA (DIANA FEA BV 2017). Twodimensional FE models of the arches to be investigated were created through Midas FX+ Version 3.3.0 Customized Pre/Post-processor for DIANA software (Midas IT 2013). According to the micro-modelling approach adopted in this work, arches were discretized as assemblies of very stiff voussoirs connected by no-tension friction interfaces (Figure 4-2). Further interface elements were placed at the springing to allow for hinge opening at the supports. The outer edges of these interface elements were pinned to provide boundary conditions (Figure 4-2). Figure 4-2 FE micro-modelling.
NUMERICAL PREDICTIONS FOR A RIGID-NO TENSION ARCH 71 The voussoirs were modelled as linear elastic elements with infinite compressive strength, whereas all the nonlinearity was concentrated in the interfaces. A Coulomb friction model (Figure 4-3) with cohesion and dilatancy angle equal to zero was adopted for interface elements, even if no sliding between blocks was expected. With the aim of simulating the opening of hinges occurring in masonry arches, the friction criterion was extended with a gap criterion with zero tensile strength so that a gap opened as tensile stresses arose. For further details about the Coulomb friction model, the reader is referred to DIANA FEA BV (2017). Figure 4-3 Coulomb friction criterion adopted in the FE model (DIANA FEA BV 2017). The values of Young’s modulus, Poisson’s ratio and unit weight adopted for the voussoirs as well as the friction angle assumed for the interfaces were derived from literature or measured experimentally (further details are provided in Sections 4.3 and 4.4.1). The interface stiffness was determined by means of a sensitivity analysis aimed at evaluating its effect on the predicted arch response. As indeed described in Lourenço et al. (2010) and Gaetani et al. (2017), this parameter can significantly affect the results of numerical simulations when dealing with masonry arches. For the purposes of this work, it was essential to guarantee that, for the adopted values of interface stiffness, arches behaved as assemblies of rigid blocks deforming only by opening hinges. The mesh of the FE models was generated adopting four-node quadrilateral isoparametric plane stress elements (Q8MEM, DIANA FEA BV 2017) for the voussoirs and 2D four-node line interface elements (L8IF, DIANA FEA BV 2017) for the interfaces. The response of the arches to large support displacements was assessed by means of nonlinear static analyses. Self-weight was firstly applied, then support displacements were increased monotonically up to collapse. A regular Newton-Raphson iteration method in combination with a line search algorithm was adopted. In order to check convergence, an energy-based convergence criterion with a tolerance value of 0.001 was assumed. Since large displacements were involved, numerical analyses were performed considering geometric nonlinearities. To this end, the Total Lagrange formulation available in DIANA software (DIANA FEA BV 2017) was adopted.
72 CHAPTER 4 72 4.2.2. Rigid block modelling The adopted rigid block modelling approach relies on a formulation based on mathematical programming which was implemented in an in-house MATLAB code (Portioli and Cascini 2017). The developed model is herein extended to include the effects of inclined support movements. The model is used for the analysis of the limit equilibrium conditions which are associated to an imposed support movement and to different geometric configurations of the structural system when large displacements are considered. With this regard, it is worth noting that the implemented modelling approach is based on a pure static formulation, i.e. the equilibrium conditions are expressed in terms of static forces, with no need to introduce inertia effects for the analysis of the failure mechanisms, as it is for most of discrete element models. The arches are modelled as assemblages of rigid blocks i interacting at no-tension, frictional contact interfaces j (Figure 4-4). The block i is subjected to vertical dead loads 𝑓 𝜌𝑉 , where 𝜌 is the unit weight and 𝑉 the volume of the block. The blocks interact at contact points k which are located at the vertices of each contact surface j with shear and normal force components 𝑡 and 𝑛 (Figure 4-5a). The positions and displacements at block centroid are collected in the vectors 𝒙𝒊𝑥𝑧𝜔 and 𝚫𝒙𝒊 Δ𝑥Δ𝑧Δ𝜔 , respectively. The displacement rates at contact points are collected in vectors 𝚫𝒖𝒌∆𝑢 ∆𝑢 (Figure 4-5b). Figure 4-4 a) Rigid block model of a circular arch subjected to support displacements; b) Rigid block i, surface j and contact point k. A movable block s is also used to model the moving support, with a single dof associated to the direction of the imposed displacement (e.g. the inclined direction with angle α in Figure 4-4a). Following classic formulations of limit equilibrium analysis, the inclined load 𝑓 applied at this block - which is work conjugated to the imposed displacement - is expressed as the sum of the constant dead load 𝑓 and the live load 𝜆𝑓 𝜆𝑓 , where 𝜆 is the unknown collapse load multiplier. As such, the inclined load at the support block can be expressed as follows: 𝑓 1𝜆 𝑓 .
NUMERICAL PREDICTIONS FOR A RIGID-NO TENSION ARCH 73 Figure 4-5 a) Dead loads and contact forces at block i and b) kinematic variables and normal gap g0k at block centroid i and contact point k. The arch response to support movements is analysed in the large displacement regime by using an incremental solution procedure that is divided into displacement increments. At each displacement increment, a force-based optimization problem and its dual displacement-based problem are solved, which are analogous to the classic lower and upper bound problems of limit analysis (Ferris and Tin-Loi 2001; Portioli and Cascini 2017). The force-based optimization problem is expressed as follows: max 𝜆𝒈 𝟎𝐓𝒄 s. t. 𝑨𝟎𝒄𝒇 𝑫𝜆𝒇 𝑳 𝒀𝐓𝒄𝟎 (1) where: 𝒄 is the (2c 1) vector of the unknown internal forces at interfaces, being c the number of contact points, which collects subvectors 𝒄𝒌𝑡𝑛; 𝒈𝟎 is the (2c 1) vector collecting the gaps between contact point k and related surfaces in subvectors 0𝑔; 𝒇𝑫 is the (3b+1 1) vector of dead loads applied at the centroid of the blocks, being b the number of the blocks of the arch. 𝒇𝑫 collects the subvectors 𝒇𝑫𝒊 0𝑓 0 and the dead load component at the support block, 𝑓 ; 𝒇𝑳 is the vector of live loads, which also contains the live load component at the support block, 𝑓 ; 𝑨𝟎 is the (3b+1 2c) equilibrium matrix, with coefficients determined by the position of contact points and geometry of rigid blocks; 𝒀𝐓 is the (3c 2c) matrix of failure conditions corresponding to sliding and opening failure at contact points. In Eq. (1) the first and second constraints represent the equilibrium and failure conditions governing the force-based problem, respectively.
74 CHAPTER 4 74 The solution procedure is organized as follows. For a given configuration 𝒙𝟎, with initial gaps 𝒈𝟎, the force-based optimization problem defined in (1) is solved to obtain the contact forces 𝒄 and the collapse load multiplier 𝜆. The kinematic variables 𝚫𝒙 and 𝚫𝒖 are obtained from the solution of the dual displacement-based problem, which is directly derived from Lagrange multipliers associated to the solution of the force-based problem. A new optimization problem is then formulated and solved on the basis of new block positions 𝒙𝒙 𝟎𝚫𝒙 and contact gaps 𝒈. 4.3. VALIDATION AGAINST EXPERIMENTAL TESTS The two modelling approaches adopted in this work were validated against the experimental tests on smallscale models performed by Ochsendorf (2002, 2006). In Ochsendorf (2002, 2006), the stability of two dryjoint masonry arches (circular and segmental) on horizontal spreading supports was investigated. Both arches were made of 16 voussoirs cast as concrete blocks and measured 50 mm in radial thickness. The circular arch had a mean radius of 220 mm and a span length of 390 mm, whereas the segmental arch had a mean radius of 385 mm and a span length of 709 mm. FE and RB models were prepared for both arches. In the FE models, a mesh with 12 elements along the radial thickness was adopted. Spreading supports were simulated by imposing an increasing outward purely horizontal displacement x at the right abutment. The unit weight of the voussoirs (25.0 kN/m3) as well as the friction coefficient of the interfaces (0.7) were taken from Ochsendorf (2002, 2006). Since the voussoirs of the experimental tests were made of concrete, the Young’s modulus and Poisson’s ratio of the blocks of the FE models were set equal to 30 GPa and 0.2, respectively. The normal stiffness kn of the interface elements used in the FE models was determined by means of a sensitivity analysis, where kn was varied between 0.1 and 100 N/mm3 according to the values proposed in Gaetani et al. (2017). The interface tangential stiffness ks was set equal to 0.5kn for any considered value of kn. This choice was made only to optimize numerical convergence, as the ratio between the two stiffnesses did not affect the structural response of the considered arches. The effect of kn on the arch response was evaluated in terms of ultimate displacement capacity, expressed as span increase at collapse x,u/L, and collapse mechanism. Figure 4-6 shows the variation in the span increase at collapse x,u/L with the interface normal stiffness kn for the circular and segmental arches. The results obtained from Ochsendorf’s experimental tests and RB models are also reported.
NUMERICAL PREDICTIONS FOR A RIGID-NO TENSION ARCH 75 Figure 4-6 – Comparison between the experimental results by Ochsendorf (2002, 2006) and the numerical results obtained from FE analyses (presented in terms of span increase at collapse x,u/L vs. interface normal stiffness kn) and RB analyses: a) circular arch, b) segmental arch. For both arches, the span increase at collapse x,u/L increases with interface stiffness kn until converging to a maximum constant value that is not affected by any further stiffness increase. This behaviour can be explained considering that small values of kn result in large interpenetration between the voussoirs, as shown by compressive stresses being distributed over several FEs (Figure 4-7a). Under these conditions, as already described by Gaetani et al. (2017), hinges do not appear at the intrados or extrados of the arch but move inward, with the result that the effective thickness of the arch is reduced, and the displacement capacity is smaller. Conversely, large values of kn significantly reduce the voussoir interpenetration and lead hinges to occur at the edge line of the arch, as shown by compressive stresses acting in only one out of the twelve FEs composing the interface (Figure 4-7b). This behaviour better simulates the response of rigid-no tension structures, as also demonstrated by the almost perfect agreement obtained between FE and RB results for large values of kn (Figure 4-6). For these reasons, a reference value of 48 N/mm3, falling approximately at the middle of the plateau region of the curve of the span increase at collapse x,u/L versus interface normal stiffness kn, was adopted for kn in the FE simulations. The interface tangential stiffness ks was set equal to 24 N/mm3. Figure 4-7 - Hinge opening in the FE model for: a) kn = 0.1 N/mm3 and b) kn = 48 N/mm3 (results shown in terms of compressive stresses in the interfaces).
82 CHAPTER 4 82 Figure 4-14 - Collapse mechanisms obtained from the FE model (left, results presented in terms of compressive stresses in the interfaces) and RB model (right): a) = 0°, b) = 15°, c) = 20°, d) = 30°, e) = 45°, f) = 90°.
NUMERICAL PREDICTIONS FOR A RIGID-NO TENSION ARCH 83 As shown in Figure 4-14, hinges A, B and C may move before the final collapse state is reached, with the results that their final position at collapse may be different from the initial one. Three different modes of evolution of the hinge configuration from the opening of the three initial hinges to collapse (hereafter named modes I, II and III) can be identified when varying the angle . For between 0° and 15° (mode I), in both the FE and RB models, hinges A, B and C remain fixed in their initial position (sequence I-E-E) and do not move as the support displacements increase. The only exception is hinge B moving by one voussoir at the very beginning of RB analyses for equal to 0° (Figure 4-14b on the right). The final hinge configuration at collapse follows the sequence E-I-E-E (Figure 4-14a- b). For equal to 20° and 25° (mode II), both FE and RB analyses predict hinge C to close at the extrados (right support) and then open at the intrados (haunches) before reaching the final collapse state (Figure 4-14c). As a result, the position of hinges A, B and C changes from the initial sequence I-E-E to the final sequence I-E-I. In the case of the FE model, hinge C does not move further once it has moved from the extrados to the intrados. Conversely, in the RB model, it moves towards the crown by some voussoirs before collapse is reached. In both models, the collapse configuration is characterized by hinges located alternately between the extrados and the intrados (sequence E-I-E-I) (Figure 4-14c). For between 30° and 90° (mode III), in both models, hinges A, B and C are located alternately between the intrados and extrados (sequence I-E-I) in both the initial and final configurations (Figure 4-14d-e-f). However, as shown in Figure 4-14d-e-f, the intrados hinges A and C move towards the crown from their initial position as the support displacements increase. For values of up to 45°, the collapse mechanism is the same as the one obtained for equal to 20° and 25°, and the final hinge location follows the sequence E-I-E-I (Figure 4-14d-e). For equal to 90°, the sequence obtained is E-I-E-I-E, as the arch fails by a fivehinge mechanism (Figure 4-14f). In view of these results, the response of the arch to inclined displacements proved to be strictly related to the predominant component of the support displacements. For between 5° and 15°, the evolution of the hinge configuration is governed by the vertical component z, since the arch exhibits the same behaviour obtained for purely vertical displacements. For between 30° and 45°, the arch response from the opening of the three initial hinges to collapse is driven by the horizontal component x. For equal to 20° and 25°, the initial and final hinge configurations are governed by z and x, respectively. It is interesting to note that, as increases, the final hinge configuration at collapse (Figure 4-14) becomes more symmetrical, changing gradually from that obtained for purely vertical displacements to that obtained for purely horizontal ones. For both FE and RB models, Figure 4-15 shows the variation in the location of hinges A, B and C as a function of the displacement applied at the right support, the latter expressed in a dimensionless way in terms of deflection ratio z/L and span increase x/L. The location where hinges D and E occur at collapse is also reported in Figure 4-15. The interfaces where hinges appear are numbered from left to right, being interface no. 1 the interface at the left support.
84 CHAPTER 4 84 Figure 4-15 - Hinge position vs. displacement applied (expressed in terms of deflection ratio z/L and span increase x/L) for values of the angle between 0° and 90° as obtained from FE and RB analyses: a) = 0°, b) = 5°, c) = 10°, d) = 15°, e) = 20°, f) = 25°, g) = 30°, h) = 35°, i) = 40°, l) = 45°, m) = 90°. Figure 4-15 confirms the results described above in terms of different evolution of the hinge configuration when varying (modes I, II and III). For between 0° and 15° (mode I), hinges A, B and C do not move as the support displacements increase (Figure 4-15a-b-c-d). For equal to 20° and 25° (mode II), hinge C closes at the right support (interface n. 56) and then opens at the haunches (Figure 4-15e-f). For between 30° and 90° (mode III), the intrados hinges A and C move gradually towards the crown (Figure 4-15g-h-i-l-m). It is worth noting that hinges change location for similar values of deflection ratio
NUMERICAL PREDICTIONS FOR A RIGID-NO TENSION ARCH 85 and span increase in the FE and RB models. Conversely, the initial jumps in the location of hinge C obtained from RB analyses for equal to 20° and 25° (Figure 4-15e-f) are only due to numerical instability. For between 25° and 45° (Figure 4-15f-g-h-i-l), the intrados hinge C seems to appear for significantly larger values of support displacement in the FE models compared to the RB models. This can be explained considering that for these values of , in the FE models, hinge C is initially distributed among consecutive interfaces. Since the authors considered a hinge to open when compressive stresses were concentrated in a single FE of an interface only, the support displacement for which hinge A appeared was overestimated. Support reaction-displacement curves This section presents the results obtained from FE and RB analyses in terms of support reactiondisplacement curves as well as ultimate displacement and corresponding support reactions at collapse. For equal to 0° and 90°, Figure 4-16 shows the support reaction-displacement curves obtained from both the FE and RB models by plotting the vertical and horizontal reactions Rz and Rx at the right (moving) support versus the deflection ratio z/L and span increase x/L, respectively. For both the considered values of , the curves from the two models are almost overlapped, except for the initial decrease in the support reactions observed in the FE model (see Section 3 for further explanations). For equal to 0° (Figure 4-16a), as the right support settles, the vertical support reaction Rz increases almost linearly, whereas the horizontal support reaction Rx has a nonlinear increase. For equal to 90° (Figure 4-16b), the vertical support reaction Rz remains constant, whereas the horizontal support reaction Rx increases nonlinearly with the span increase x/L. It is worth noting that the discontinuities in the horizontal support reaction-span increase curve of the FE model (Figure 4-16b) are caused by the movement of the intrados hinges from one voussoir to the next. Figure 4-16 - Support reaction-displacement curves obtained from FE and RB analyses for a) = 0° and b) = 90°: curves vertical reaction Rz vs. deflection ratio z/L, and curves horizontal reaction Rx vs. span increase x/L. The support reaction-displacement curves obtained from FE and RB analyses for between 0° and 45° and equal to 90° are presented in Figure 4-17. The value of the horizontal support reaction Rx,min calculated by graphic statics (Heyman 1982; Huerta 2011) when the arch is in the state of minimum thrust due to a small outward movement of the supports is also provided for comparison. Note that, in the minimum thrust
86 CHAPTER 4 86 state, hinge B opens at the extrados at mid-span, while hinges A and C are located at the intrados between 5th and 6th voussoirs. FE and RB analyses predict the same results in terms of support reaction-displacement curves. In both models, all the curves obtained for between 5° and 45° are included between those derived for equal to 0° and 90°, suggesting that a similar response could be obtained for any between 45° and 90°. Three different groups of curves, corresponding to the modes I, II and III described in Section 4.2.1, are obtained for = 0°÷15°, =20°÷25°, and =30°÷90°. As increases from 0° to 15°, the rate of increase decreases for the horizontal support reaction, while it increases for the vertical one. For between 30° and 90°, the curves of the vertical reaction Rz versus deflection ratio z/L as well as the curves of the horizontal reaction Rx versus the span increase x/L are almost overlapped for every value of . The curves obtained for equal to 20° and 25° follow those derived for between 0° and 15° until a net discontinuity in the values of the horizontal and vertical support reactions is produced by hinge C closing at the extrados and subsequently opening at the intrados (see Section 4.2.1). Then, the same trend of the curves obtained for between 30° and 90° is followed. The initial fluctuations of the support reactions predicted by the FE and RB models for equal to 20° and 25° are due to numerical instability. Figure 4-17 – Support reaction-displacement curves for between 0° and 45°, and equal to 90°: curves vertical reaction Rz vs. deflection ratio z/L obtained from FE analyses (a) and RB analyses (c); curves horizontal reaction Rx vs. span increase x/L obtained from FE analyses (b) and RB analyses (d). Comparison with the minimum thrust calculated by graphic statics Rx,min is provided in b) and d).
NUMERICAL PREDICTIONS FOR A RIGID-NO TENSION ARCH 87 It is worth noting that for between 30° and 90° the initial value of the horizontal support reaction Rx predicted by the RB analyses (equal to 9.4 N) is almost identical to the minimum thrust obtained from graphics statics (Rx,min = 9.5 N) (Figure 4-17d). Also in FE analyses, the minimum value reached by Rx after its initial decrease (ranging between 9.5 N and 9.7 N depending on ) is very similar to the minimum thrust Rx,min (Figure 4-17c). This result could be expected since the initial location of hinges A, B and C predicted by the FE and RB analyses (see Figure 4-13b) is the same as obtained in the condition of the minimum thrust. Conversely, for values of between 0° and 15°, for which hinges A, B and C appear in the sequence I-E-E, the minimum value of the horizontal support reaction Rx is larger than Rx,min , being equal to about 10.6 N in both the FE and RB models. Figure 4-18 reports the results obtained from FE and RB analyses in terms of support reactions, deflection ratio and span increase at collapse when varying between 0° and 90°. The two modelling approaches predict very similar values of deflection ratio and span increase at collapse, with differences lower than 4% for every value of considered. As the angle increases, the deflection ratio at collapse z,u/L decreases, dropping from about 21.2% for equal to 0° to about 0.5% for equal to 85° (Figure 4-18a). The rate of decrease is different in the three ranges of corresponding to modes I, II and III. It is worth noting that, although the horizontal component of support displacements is smaller in the case of mode I, the deflection ratio at collapse z,u/L decreases faster for ranging between 0° and 15°. In both models, the span increase at collapse x,u/L increases significantly up to an angle of 25° (modes I and II) (Figure 4-18b), while it remains almost constant for between 30° and 90° (mode III). In this latter range, the values of span increase at collapse predicted by the FE and RB models are equal to about 5.7% and 5.5%, respectively. Comparing the deflection ratio and span increase at collapse obtained for equal to 0° and 90°, respectively, the arch is found to exhibit a significantly larger capacity to withstand vertical support displacements compared to horizontal support displacements. The results obtained from the FE and RB analyses are in very good agreement also in terms of support reactions at collapse, with differences lower than 3% and 1% for the horizontal and vertical reactions, respectively (Figure 4-18c-d). In both models, the vertical support reaction at collapse Rz,u decreases with increasing up to 15° (mode I), increases abruptly between 15° and 20° due to the transition from mode I to mode II, and then decreases at a lower rate up to 90° (mode III) (Figure 4-18c). The horizontal support reaction at collapse Rx,u increases with increasing except for equal to 20°, for which it sharply drops due to the transition from mode I to mode II (Figure 4-18d). It is worth noting that the rate of increase is significantly smaller for between 30° and 90° than for between 0° and 15°. As it can be observed from Figure 4-18, the results obtained from the RB analyses for angles between 50° and 85° follow the same trend observed for ranging between 30° and 45°. Consequently, the considerations regarding initial hinge configuration, hinge movement and collapse mechanism made so far for between 30° and 45° can be extended to any angle between 50° and 85°.
88 CHAPTER 4 88 Figure 4-18 – Results obtained at collapse from the FE and RB analyses when varying the angle between 0° and 90° (modes I, II and III are also indicated): a) deflection ratio at collapse z,u/L, b) span increase at collapse x,u/L, c) vertical support reaction at collapse Rz,u and d) horizontal support reaction at collapse Rx,u. Limit displacement domain The RB model was used to determine the limit displacement domain of the analysed arch as a function of the angle (Figure 4-19). The boundary of the domain consists of the pairs of deflection ratio-span increase values obtained at collapse for ranging between 0° and 90°. The points below the boundary represent all the combinations of vertical and horizontal support displacements that the arch can sustain safely. Conversely, the pairs of deflection ratio-span increase values falling above the boundary are collapse states. The x-axis and the y-axis represent purely horizontal ( = 90°) and purely vertical ( = 0°) support displacements, respectively. The limit displacement domain of the analysed arch exhibits three different trends, corresponding to modes I, II and III, when varying (Figure 4-19). For between 0° and 15° (mode I) and equal to 20° and 25° (mode II), the deflection ratio at collapse z,u/L decreases linearly with increasing span increase at collapse x,u/L. However, a larger rate of decrease is obtained for mode I with respect to mode II. For values of between 30° and 90° (mode III), the deflection ratio at collapse z,u/L gradually decreases with increasing , while the span increase at collapse x,u/L remains almost constant. It is worth noting that, although the final hinge location at collapse follows the sequence E-I-E-I for both modes II and III, the different evolution of the hinge configuration from the opening of the three initial hinges to collapse results
NUMERICAL PREDICTIONS FOR A RIGID-NO TENSION ARCH 89 in significantly different values of deflection ratio and span increase at collapse for equal to 20° and 25° and between 30° and 90°. Figure 4-19 – Limit displacement domain for the segmental arch under consideration (modes I, II and III are also indicated). 4.5. SENSITIVITY ANALYSIS TO THE NUMBER OF VOUSSOIRS A sensitivity analysis to the number of voussoirs was performed for the considered segmental arch using the RB model. Results from literature for arches on spreading supports (Coccia et al. 2015; Galassi et al. 2018; Ochsendorf 2002, 2006) have demonstrated that the number of voussoirs affects the arch response in terms of both hinge position and collapse displacement. In view of this, in the present work, the effect of the number of voussoirs on the deflection ratio and span increase at collapse for equal to 0° and 90°, respectively, was investigated. Furthermore, in order to assess the sensitivity of the results to the voussoir discretization when varying the direction of the support displacements, the effect of the number of voussoirs on the limit displacement domain of the arch was evaluated. Figure 4-20 shows the variation in the deflection ratio at collapse z,u/L with the number of voussoirs for equal to 0°. The value obtained for an arch made of 500 voussoirs, which is representative of a theoretical continuous arch, is also reported. It is interesting to note that the deflection ratio at collapse z,u/L oscillates around the value obtained for the theoretical continuous arch (equal to 21.5%) with abrupt decreases for arches with very similar numbers of voussoirs. When arches are made of few blocks, large variations (up to about 16%) in the deflection ratio at collapse z,u/L are obtained. In contrast, as the number of voussoirs increases, the arch response becomes less sensitive to the voussoir discretization, and the deflection ratio at collapse z,u/L converges to a stable value of about 21.5%. δz,u /L [%]
90 CHAPTER 4 90 Figure 4-20 - Deflection ratio at collapse z,u/L vs. number of voussoirs for = 0°. An asymmetrical four-hinge collapse mechanism with hinges located in the sequence E-I-E-E (mode I) is obtained for any number of voussoirs considered. Hinges C and D always occurs at the right and left support, respectively, whereas hinges A and B change location with the number of voussoirs. For the sake of brevity, the results obtained for hinge B are not reported, as they affect the arch response only marginally. As shown in Figure 4-21, the radial position of hinge A at collapse, corresponding to the angle shown in Figure 4-22, oscillates around the radial position obtained in the theoretical continuous arch (indicated as t and equal to 15.8°). Note that hinge A does not move with the increase of support displacements; thus, its final position at collapse is the same as the initial one. As the radial position of hinge A gradually decreases, the deflection ratio at collapse z,u/L gradually increases (see the results obtained for arches with 5, 8 and 11 voussoirs, indicated with grey circles in Figure 4-20 and Figure 4-21). Furthermore, any sudden increase in the radial position of hinge A corresponds to an abrupt decrease in the deflection ratio at collapse z,u/L (see the results obtained for 11 and 12 voussoirs in Figure 4-20 and Figure 4-21). This clearly indicates that the changes in the deflection ratio at collapse z,u/L with the number of voussoirs are caused by the variations in the radial position of hinge A. Figure 4-21 - Radial position of hinge A at collapse, , vs. number of voussoirs for = 0°. Figure 4-22 shows the collapse configuration as well as the radial position of hinge A, , for arches made of 5, 8, 11, 12, 19 and 20 voussoirs. The radial position of hinge A for the theoretical continuous arch, t, is provided for comparison. 0 20 40 60 80 100 120 140 160 180 200 220 Number of voussoirs 10 15 20 25 30 Theoretical continuous arch 12 28 35 55 20 19 11 5 8 0 20 40 60 80 100 120 140 160 180 200 220 Number of voussoirs 10 15 20 25 30 Theoretical continuous arch 12 19 20 5 8 11 28 35 55
NUMERICAL PREDICTIONS FOR A RIGID-NO TENSION ARCH 91 Figure 4-22 – Radial position at collapse of hinge A, , and deflection ratio at collapse, z,u/L, for arches with a) 5, b) 8, c) 11, d) 12, e) 19 and f) 20 voussoirs ( t indicates the radial position of hinge A in the theoretical continuous arch). Looking at Figure 4-22, it is interesting to observe that hinge A always opens at the interface located closest to the radial position t, regardless of the number of voussoirs. For an arch made of 5 voussoirs, hinge A occurs between the 1st and 2nd voussoir at a radial position equal to 25.1°. As the number of voussoirs increases from 5 to 11, the radial position decreases, as expected since hinge A is always located between the 1st and 2nd voussoir. However, for an arch made of 12 voussoirs, hinge A opens between the 2nd and 3rd voussoir (Figure 4-22d), producing the abrupt increase in the radial position described above. It is worth noting that every time hinge A moves by one voussoirs towards the crown (see Figure 4-22e-f as an example), the radial position increases sharply and then decreases gradually until a further increase is obtained (Figure 4-21). As a result, large variations in the deflection ratio at collapse z,u/L can be obtained for arches with a similar number of voussoirs, especially when few voussoirs are considered. From the results obtained for arches made of 5, 8 and 11 voussoirs (Figure 4-22a-b-c), it is easy to observe that the more hinge A appears close to the left support, the larger is the deflection ratio at collapse
98 CHAPTER 5 98 on their long narrow side with the short end exposed, as typically observed in Italian two-course brick barrel vaults (see Figure 5-1). This choice was based on practical reasons, since reproducing exactly the real brick pattern would have required the production and assembly of very small voussoirs, making the construction of the physical model unduly complicated. The depth of the voussoirs (120 mm) was chosen sufficiently large to avoid compromising the model stability under accidental actions. In this respect, it is worth noting that the model depth does not influence the experimental results since the arch is characterised by a bidimensional behaviour. Figure 5-1 Geometry of the arch mockup (in mm). All the blocks (voussoirs and piers) are made of a bicomponent composite material (Plastoform PL, Prochima 2019), which was poured, let it harden and then removed from special silicone moulds. The use of this manufacturing technique to create blocks is an innovation in the framework of small-scale model testing, which often employs 3D printed plastic blocks (e.g. Calvo Barentin et al. 2017; Foti et al. 2018; Rossi et al. 2016; Rossi et al. 2017; Quinonez et al. 2010; Van Mele et al. 2012; Zessin et al. 2010). Compared to the 3D printing technology, this technique allows a significant reduction of the cost of production of the scale models, as no special equipment or machinery is required, and, in addition, it enables to easily re-create new blocks as soon as they are needed in any laboratory. Furthermore, this material offers several advantages over other grouts traditionally used for small-scale dry-joint models, such as cast concrete (e.g. Ochsendorf 2002, 2006; Romano 2005; Romano and Ochsendorf 2010). The main benefits are the following: It allows producing very small blocks with good dimensional accuracy. It is easy to mix, even manually, without requiring any special tool. It can be poured in silicone moulds appropriately designed. It hardens fast and can be demoulded approximately 90 minutes after the pouring. It does not experience any appreciable shrinkage. However, as a drawback, the bicomponent composite blocks are characterized by a low hardness, with the results that they may get damaged when crashing into each other at collapse and thus they need to be
EXPERIMENTAL TESTS 99 replaced. A further disadvantage is that the bicomponent composite material is very sensitive to the environmental conditions. In particular, when the two components are mixed in a hot and moist environment, the mixture becomes highly viscous, making the pouring very difficult. As a consequence, the material and mechanical properties may be slightly different depending on the season of the year in which the blocks are produced. In any case, this technique enables the production of blocks with high compressive strength and stiffness (they can be considered almost rigid) and friction (sliding between blocks is inhibited), which is in accordance with Heyman’s hypotheses about masonry mechanical behaviour. A Young’s modulus E ranging between 590 MPa and 941 MPa was measured by testing 6+6 bicomponent composite prisms (dimensions of about 40x40x80 mm3) under uniaxial compression (Figure 5-2). A friction angle Φ = 41.2° was determined by testing 10 couples of arch voussoirs on an inclined plane. The mass density of the bicomponent composite material was about 1.57-1.64 g/cm3. Figure 5-2 Bicomponent composite prisms tested under uniaxial compression. To produce the blocks of piers and voussoirs, special silicone moulds were created by pouring the silicone into wooden formworks containing aluminium matrices having the same shape as the blocks (Figure 5-3). The aluminium matrices were manufactured using a manual milling machine in the case of the blocks of the piers, whereas a CNC machine (precision 0.05mm) was used for the arch voussoirs. a) b ) Figure 5-3 Preparation of the silicon moulds: a) aluminium matrices placed in the wooden formwork; b) pouring of the silicone. Figure 5-4 illustrates the manufacturing process of the blocks in the case of the arch voussoirs.
100 CHAPTER 5 100 a) b) c) d) e) f) Figure 5-4 Manufacturing process of the arch voussoirs: a) mixing of the two components, b) application of a small amount of material on the internal surface of the mould, c) pouring of the mixture into the mould, d) mechanical vibration of the mould e) hardening of the mixture, f) voussoirs ready to be used. The mineral powder and the acrylic polymer in aqueous solution composing the bicomponent composite material, combined in a powder-to-liquid weight ratio of 100/40, were mixed until a homogenous fluid mixture was obtained (Figure 5-4a). A small amount of material was applied on the internal surface of the mould to prevent the formation of air bubbles (Figure 5-4b). The remaining mixture was then poured into the mould and let it harden (Figure 5-4c-e). Before the material set, the mould was vibrated mechanically in order to eliminate the air bubbles from the freshly poured mixture (Figure 5-4d). About 90 minutes after
EXPERIMENTAL TESTS 101 the pouring, the blocks could be extracted from the mould and used to build the physical model (Figure 5-4f). Note that in the case of arch voussoirs the mixture was fluidified by adding a plasticizer (1% of the total weight) to facilitate the pouring into the mould. The aluminium matrix and silicone mould used to create the blocks of the piers are shown in Figure 5-5a and Figure 5-5b, respectively. In Figure 5-5c and Figure 5-5d, one of the piers is depicted before and after hardening. As can be observed from Figure 5-5, the blocks of the piers are designed as a sort of Lego system, allowing to add parallelepiped blocks above and below. This solution will enable to test more complex arch-pillar systems in future experimental campaigns. a) b) c) d) Figure 5-5 Production of the blocks of the piers: a) aluminium matrix; b) silicone mould; block before (c) and after (d) hardening. Figure 5-6 displays a sequence of images describing the construction of the arch model. In order to build the arch, a temporary supporting structure (centering) made of plywood was constructed (Figure 5-6b). It is directly supported on the blocks of the piers, which were specially shaped so that no further support was required. The centering is provided with three regulation screws that enable to adjust it to the required height and remove it from underneath when the arch is completely assembled (Figure 5-6e-f-g). It is important to highlight that the system of regulation screws is designed such that the centering can be lowered uniformly along the entire profile of the arch (Figure 5-6e-f), preventing as much as possible the
102 CHAPTER 5 102 occurrence of asymmetric deformations during the centering removal. Figure 5-6g shows a view of the physical model after the removal of the supporting structure. Detail views of the scaled arch are presented in Figure 5-7. a) b) c) d)
EXPERIMENTAL TESTS 103 e) f) g) h) Figure 5-6 Construction of the physical model of the arch: a) positioning of the blocks of the piers, b) positioning of the centering, c-d) arch construction by placing the voussoirs at the extrados of the centering, e-f-g) centering removal, g) physical model after the removal of the centering.
104 CHAPTER 5 104 a) b ) Figure 5-7 Detail views of the scaled arch: a) intrados, b) extrados. 5.3. EXPERIMENTAL SET-UP 5.3.1. Application of support displacements The arch was tested to collapse by applying increasing displacements at one support. A special testing device was designed ad hoc to perform the experimental tests (Figure 5-8). It consists of a frame made of welded steel tubular profiles supporting two aluminium squared plates where the two piers of the arch can be placed. The left support is fixed, whereas the right support can be moved in different directions thanks to a system of guides and three stepping motors (SANYO DENKI 2020) controlled via software (Figure 5-8 and Figure 5-9). As shown in Figure 5-9, the stepping motors SM1 and SM2 assign vertical ( z) and horizontal ( x) displacements, respectively, and they can be activated separately or simultaneously to produce inclined displacements. The stepping motor SM3 (Figure 5-9b) allows the right supporting plate to rotate with respect to the horizontal. Although this possibility was not considered in this research, the same displacement value needs to be assigned by motors SM1 and SM3 to move vertically the right supporting plate without any rotation. A particularly interesting potential of this testing device is that it can be used not only for the arch under consideration, but also for different specimens with a two-dimensional behaviour, such as arch-pillar systems or wall panels, provided that their geometry fits the size of the supporting plates. For the purpose of this research, downward vertical, outward horizontal and outward inclined displacements were imposed. The angle , which is measured with respect to the vertical and represents the direction of the imposed displacements (see Figure 4-1), was varied between 0° and 90°, considering increasing steps of 5° between 0° and 45°, and steps of 15° between 45° and 90°. Displacements were applied at very low speeds to avoid dynamic effects that would not have been compatible with the slow development of phenomena like slow-moving landslides and foundation settlements. In the case of purely vertical and horizontal displacements, a speed of 0.04 mm/s was adopted. In the case of inclined displacements, the velocity of the predominant component of the displacement, either
EXPERIMENTAL TESTS 105 vertical or horizontal, was set equal to 0.04 mm/s and the speed of the other component was reduced so as to obtain to required value of . a) b) c) Figure 5-8 Testing machine: a) 3D CAD model, b) front view, c) lateral view.
106 CHAPTER 5 106 a) b) Figure 5-9 System of guides and stepping motors to impose vertical (a) and horizontal (b) support displacements. 5.3.2. Measuring systems Two measuring systems were implemented to: (i) monitor the reactions at the base of the arch, and (ii) track the displacements of all the individual voussoirs. The reactions at the supports of the mock-up were measured through a system of load cells (Figure 5-10). The sampling frequency was set to about 1600 Hz. At each support, three load cells monitored the vertical component of the reaction, whereas one was used for the horizontal component. All the load cells were positioned between two squared aluminium plates supported on the testing device so that the entire measuring system could be easily removed when it was not needed (Figure 5-10a). As shown in Figure 5-10b, the load cells measuring the vertical reaction were mounted along the edges of the lower plate (400 x 400 x 15 mm3), two (indicated as V1 and V3 in Figure 5-10b) at the vertices of the external side and one (indicated as V2 in Figure 5-10b) at the middle of the internal side. The load cell monitoring the horizontal reaction (indicated as H1 in Figure 5-10b) was located at the middle of the external side. The upper plates (440 x 440 x 15 mm3) provided a bearing plane for the piers of the arch and were supported each on the
EXPERIMENTAL TESTS 107 three cells V1, V2 and V3 through aluminium rollers (Figure 5-10c). The rollers were essential for ensuring a correct measurement of the horizontal reaction, as they did not produce additional constraints and enabled the upper plates to move horizontally. Figure 5-10d shows the solution adopted to measure the horizontal reaction. An aluminium plate (40 x 82 x 20 mm3) was screwed underneath the upper supporting plate. This plate was connected to the load cell H1 though a steel bar having at the extremities two rod ends. The rod ends allowed the steel bar to move vertically when the weight of the physical model was transmitted to the vertical plate. This prevented that part of this vertical load was transferred to the load cell H1, altering the correct reading of the vertical reaction by the load cells V1, V2 and V3. As a result, the measurement of the horizontal reaction was uncoupled from the measurement of the vertical one. a) b) c) d) Figure 5-10 System of load cells to measure the support reactions: a) 3D view, b) 2D view of the lower plate where the load cells are mounted, 3) detail view of one load cell used to measure the vertical reaction, 4) detail view of the solution adopted to measure the horizontal reaction. The displacements of all the blocks of the arch were tracked using a high definition, high-rate digital camera (Dalsa Falcon2 FA-80-4M180-01-R-4 Megapixels), equipped with an infrared lamp and an infrared filter. Reflective markers were placed on the mockup, two per voussoir and five on the piers, for a total of 115 targeted points (Figure 5-11). A sequence of images was acquired by the camera during the tests and the position of the markers was estimated by means of a software running on one computer (see Lunghi et al. 2012 for further details on the acquisition system). This enabled to follow the evolution of the
114 CHAPTER 5 114 by performing graphic statics and analysing the evolution of the displacements of the voussoirs recorded by the infrared camera (see results further below in this section). As shown in Figure 5-16b and Figure 5-17a, hinge A opens between 8th and 9th voussoirs, at the same location observed for between 0° and 15°. For = 15° only, hinge A moves by one voussoir towards the crown just before collapse (compare hinge position in Figure 5-16d-e). Hinge B appears in a slightly different position according to the value of considered, opening closer to the keystone as increases. For = 15° (Figure 5-16), it appears between 30th and 31st voussoirs, whereas for = 20° it is located between 29th and 30th voussoirs. For = 25°, it appears between 31st and 32nd voussoirs, and then it moves towards the crown by four voussoirs (Figure 5-17b-c), opening at the left side of the keystone (i.e. between 27th and 28th voussoirs). For = 30° (and for every larger value of ), hinge B opens between 27th and 28th voussoirs and does not change position as the right support moves. a) b) c) d) e) f) Figure 5-16 Damage evolution for = 15°: a) z/L = 3.0%, b) z/L = 4.7%, c) z/L = 6.6 %, d) z/L = 9.1%, e) collapse for z/L = 9.1%, f) unstable configuration corresponding to z/L = 9.1%.
EXPERIMENTAL TESTS 115 a) b) c) d) e) f) Figure 5-17 Damage evolution for = 25°: a) z/L = 2.8%, b) z/L = 3.8%, c) z/L = 4.7%, d) z/L = 5.6%, e) collapse for z/L = 7.6%, f) unstable configuration corresponding to z/L = 7.6%. For between 35° and 75° (see Figure 5-18 and Figure 5-19 and for = 35° and = 75°, respectively), three hinges can again be detected before collapse occurs. However, differently from what observed for ranging between 0 and 10°, they alternate between the intrados and extrados (sequence I-E-I, Figure 5-18e and Figure 5-19e). The two hinges A and B open at the early stages of the tests (see Figure 5-18a-b-c and Figure 5-19a), whereas hinge C appears for larger imposed displacements and is generally slightly distributed over consecutive interfaces (see Figure 5-18d-e and Figure 5-19b-c-d). For every value of between 35° and 75°, hinge A initially appears between 8th and 9th voussoirs, and then it moves towards the crown as support displacements increase. As increases, hinge A moves up by a larger number of voussoirs. For equal to 35° and 40°, it moves up by one voussoir only (see Figure 5-18d for = 35°), whereas for between 45° and 75° it moves further up the arch by two voussoirs (see Figure 5-19b-c for = 75°). The change in the position of hinge A generally produces a sudden change in the arch geometry,
116 CHAPTER 5 116 triggering in some cases the activation of the collapse mechanism. For equal to 35°, 45° and 60°, collapse occurs immediately after hinge A has suddenly moved up (see Figure 5-18d-e for = 35°). Hinge C also moves towards the crown as the right support moves (compare the hinge position in Figure 5-19c-d for = 75°). However, since it is slightly distributed over consecutive interfaces, this movement is more gradual and not always easy to detect. Hinge C initially appears between 10th and 13th voussoirs (numbered from the right support). At collapse, it is located either between 11th and 12th voussoirs or between 12th and 13th voussoirs, depending on the value of under consideration. Differently, hinge B always opens between 27th and 28th voussoirs and does not change position as the right support moves. a) b) c) d) e) f) Figure 5-18 Damage evolution for = 35°: a) z/L = 1.9%, b) z/L = 3.2%, c) z/L = 4.7%, d) hinge movement for z/L = 5.5%, e) collapse for z/L = 5.5%, f) unstable configuration corresponding to z/L = 5.5%. As shown in Figure 5-18e and Figure 5-19e, the arch starts to collapse when a fourth hinge, D, opens at the left support at the extrados. The location of hinge C may vary once the arch has reached its unstable configuration and the collapse mechanism progresses up to the total failure (Figure 5-18f andFigure 5-19f).
EXPERIMENTAL TESTS 117 However, it is assumed that the final hinge configuration is the one obtained at the instant of activation of the mechanism (Figure 5-18e and Figure 5-19e). a) b) c) d) e) f) Figure 5-19 Damage evolution for = 75°: a) z/L = 0.6%, b) z/L = 0.8%, c-d) hinge movement for z/L = 1.0%, e) collapse for z/L = 1.0%, f) unstable configuration corresponding to z/L = 1.0%. For = 90° (Figure 5-20), the three initial hinges A, B and C alternate between the intrados and extrados, as observed for ranging between 35° and 75°. Looking at Figure 5-20a-b-c, it is observed that hinge B is distinctly located at the left side of the keystone (between 27th and 28th voussoirs), whereas hinges A and C are initially distributed over consecutive interfaces, and they tend to concentrate each in a single one only as the right support moves. Hinge B does not move during the test, whereas both hinges A and C move gradually towards the crown as support displacements increase. For a horizontal displacement of about 18 mm (Figure 5-20c), corresponding to a span increase x/L of about 3.4%, hinge A is located between 10th and 11th voussoirs (from the left), while hinge C is placed between 11th and 12th voussoirs (from the right). Just before collapse, hinge A moves up by a further voussoir (Figure 5-20d).
118 CHAPTER 5 118 Collapse is triggered when two further hinges, D and E, appear at the extrados at the supports (Figure 5-20e). As shown in Figure 5-20f, the opening of hinges D and E causes the parts of the arch between the supports and the intrados hinges (i.e. block LS-A and blocks C-RS) to rotate upwards, and the crown to descend. The collapse mechanism is almost symmetrical, since hinges appear at both supports and, furthermore, both the intrados hinges A and C are located in correspondence to the 12th interface from the springings, in a symmetrical position with respect to the vertical axis of symmetry of the arch. The slight asymmetry is only due the presence of the keystone, which prevents the occurrence of a hinge exactly at mid-span. This result proves that the physical model was built with a good accuracy. Indeed, although perfectly symmetric arches collapse by a five-hinge mechanism, past experimental tests on arches on horizontal spreading supports (e.g. Ochsendorf 2002, 2006) demonstrated that the imperfections of the physical models may result in a four-hinge mechanism. a) b) c) d) e) f) Figure 5-20 Damage evolution for = 90°: a) x/L = 2.8%, b) x/L = 3.2%, c) x/L = 3.4%, d) hinge movement for x/L = 3.7%, e) collapse for x/L = 3.7%, f) unstable configuration corresponding to x/L = 3.7%.
EXPERIMENTAL TESTS 119 Based on the above considerations, it is observed that the final hinge configuration at collapse becomes more symmetrical as increases, approaching the one obtained for purely horizontal displacement ( = 90°). First, as already mentioned in the previous paragraphs, hinge B appears closer to mid-span with increasing . For between 5° and 20° it is located either between 29th and 30th voussoirs or between 30th and 31st voussoirs, whereas for any equal or larger than 25° it opens at the left side of the keystone, at the same position in which it appears for = 90°. Furthermore, as increases, the final location of the intrados hinges A and C becomes more symmetrical with respect to the vertical axis of the arch. This explain why hinge A, which initially opens at the 9th interface from the left support, moves up by a larger number of voussoirs as increases. Indeed, it has to approach the final position of hinge C, which, at collapse, is located at the 12th or 13th interface from the right support. In an attempt to better understand the collapse mechanisms obtained for between 15° and 30° and detect the opening of further hinges, the arch deformed configuration at collapse (i.e. as soon as hinge D has started to open) was verified by means of graphics statics (Heyman 1982; Huerta 2011) (Figure 5-21). It is well known that the thrust line at collapse is unique and causes as many plastic hinges as needed to develop a mechanism (Heyman 1966; Roca 2010). Four hinges are required in the case of asymmetry in geometry and/or loading, while five hinges generally occur in the case of symmetry in both geometry and loading. In Figure 5-21, the results from graphics statics are also provided for equal to 0° and 35°, for which four hinges were clearly visible. In these cases (Figure 5-21a-f), as expected, the thrust line touches the arch boundary in four points, which correspond to the four hinges producing the collapse mechanism. For between 15° and 30°, Figure 5-21b-c-d-e shows the thrust line at collapse, which was drawn considering the position of the hinges D, A and B. For = 15° (Figure 5-21b), the thrust line touches the external boundary of the arch at the extrados at the right support, indicating that a fourth hinge occurs there. This proves that the collapse mechanism obtained for = 15° is very similar to that identified for between 0° (Figure 5-21a) and 10°. Conversely, for between 20° and 30°, a fourth hinge cannot be identified, as the thrust line does not become tangent to the boundary of the arch in a further section. However, it can be observed that it is close to touch the intrados at the right haunch, being almost parallel to the internal boundary for some consecutive voussoirs. Interestingly, the thrust line moves closer to the intrados as increases.
120 CHAPTER 5 120 Figure 5-21 Thrust line obtained by graphic statics: a) = 0°, b) = 15°, c) = 20°, d) = 25°, e) = 30°, f) = 35°. Further insight on the hinge opening as well as on the development of the arch deformed configuration with increasing support displacements can be gained by analysing the evolution of the displacements of the voussoirs as tracked by the infrared camera during the tests. Figure 5-22 shows the position of the markers taken into consideration for this purpose.
EXPERIMENTAL TESTS 121 Figure 5-22 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs ( z,v) and the change in the distance between adjacent voussoirs ( dv) with respect to the initial distance dv,0. For the voussoirs between hinge B and the right support (markers coloured in red in Figure 5-22), the evolution of the measured vertical displacement z,v, net of the imposed vertical displacement, was investigated. This can provide an estimate of the movements experienced by the right part of the arch, allowing to detect the opening of hinges that are not distinctly visible. Figure 5-23 plots z,v as a function of the imposed vertical displacement z, expressed in terms of deflection ratio z/L, for every value of under study. Note that positive and negative values of z,v indicate that the vertical displacements of the voussoirs are larger or smaller than the imposed displacement, respectively. The vertical displacement of the right pier (indicates as RS in Figure 5-23) is also reported for reference. Different responses are obtained when varying . For between 0° and 15° (Figure 5-23a-b-c-d), z,v increases in absolute value with increasing support displacements. At each displacement increment, the vertical displacements of the voussoirs are smaller than the imposed displacement and are proportional to the distance of each marker from the right support. This clearly indicates that the right part of the arch between hinge B and the right support (block B-RS) rotates upwards. This result provides further confirmation of the opening of a hinge at the right springing at the extrados for = 15°. As increases, the upward rotation decreases, in agreement with the smaller opening of hinge C observed for equal to 5° and 10° (Figure 5-14 and Figure 5-15). It is also interesting to note that the increase in z,v becomes less linear with increasing , in particular in the case of the markers closer to hinge B. Since a perfectly linear increase would indicate a rigid rotation around a well-defined hinge, it is likely that block B-RS does not behave exactly like a rigid body, but minor and distributed openings also occur. This behaviour is more evident in the case of =15°, for which a slight decrease in z,v, indicating a slight rotation downwards, is also observed for markers 31i-37i. For = 20° (Figure 5-23e), a clear change in the trend is observed as support displacements increase. Up to a vertical displacement of about 22 mm ( z/L = 4.1 %), block B-RS experiences a slight rotation upwards, then it starts rotating downwards. Once the arch has recovered its initial rotation ( z,v is almost zero for all the markers), for a vertical displacement of about 42 mm ( z/L = 7.9 %) the upper part of block B-RS (markers 30i-44i) slightly rotates downwards. Since it was demonstrated that the thrust line obtained at collapse for = 20° does not touch the arch boundary in any further point between hinges B and C, it is
122 CHAPTER 5 122 likely that this part of the arch experiences a sort of deformation due to the occurrence of minor and distributed openings at the intrados, rather than a rigid rotation around a well-defined hinge. Further evidence is provided by the non-linear increase in z,v. For = 25° (Figure 5-23f), starting from to a vertical displacement of about 20 mm ( z/L = 3.8 %), the part of the arch between markers 28i and 45i rotates downwards. Similarly to what is observed for = 20°, the non-linear increase of the vertical displacements suggests the occurrence of distributed openings at the intrados between hinge B and the right support. The different trend in the increase of z,v observed for markers 28i-31i is simply due to the change in the position of hinge B occurring with the increase of support displacements. For any between 30° and 75° (Figure 5-23g-h-i-l-m-n), the part of the arch between approximately markers 28i and 45i experiences a downward rotation, increasing with increasing , from the very beginning of the experimental test. As increases, the increase of z,v becomes more linear, indicating that the upper voussoirs tend to rotate as a rigid body around a well-defined hinge. This was expected, as a hinge was clearly visible at the intrados at the right haunch for any between 35° and 75°. Furthermore, for equal to 35°, it was demonstrated that the thrust line at collapse touches the internal boundary of the arch at the right haunch. The abrupt changes in z,v observed for between 40° and 75° indicate that the intrados hinges move towards the crown as support displacements increase. In view of the above-mentioned results, some remarks about the structural behaviour of the arch when varying can be put forward. First, in the cases in which, at collapse, only three hinges are detected and the thrust line touches the arch external boundary only in three points (i.e. for between 20° and 30°), the mobility needed to develop the collapse mechanism is provided by the occurrence of very minor and distributed openings at a further section of the arch (right haunch at the intrados). These distributed openings, whose presence is confirmed from the analysis of the distance between adjacent voussoirs (see results further below in this section), allow the downward rotation of block B-C and, thus, have the same effect as a hinge in the activation of the collapse mechanism. Second, the occurrence of minor distributed openings rather than a fully developed one at the intrados at the right haunch can be related to the geometry of the arch deformed configuration, which is different for each value of since it results from the combination of the vertical and horizontal components of the displacement applied. For between 20° and 30°, the downward rotation of block B-C is very small (Figure 5-22e-f-g). Consequently, minor and distributed openings are sufficient to provide the arch with the mobility needed to activate collapse. In contrast, when increases, the rotation becomes larger, and a fully developed hinge is required at the intrados. This explains why the thrust line moves closer to the intrados as increases between 20° and 30° (see Figure 5-21) and also justifies why these distributed openings can be considered equivalent to a hinge. Third, combining the results obtained in terms of evolution of voussoirs’ displacements with the failure modes observed in the tests, three different modes of evolution of the hinge configuration can be identified when varying :
EXPERIMENTAL TESTS 123 For between 0° and 15°, the three initial hinges follow the sequences I-E-E (from the fixed support) for every value of imposed displacements and do not generally move as support displacements increase. Collapse occurs by an asymmetrical four-hinge mechanism when a further hinge opens at the left support at the extrados (sequence E-I-E-E). For equal to 20°, the three initial hinges A, B and C are initially located according to the sequence I-E-E. As support displacements increase, hinge C closes at the extrados (right support) and opens (in the form of minor and distributed openings) at the intrados (right haunch). As a result, failure is governed by an asymmetrical four-hinge collapse mechanism with hinges located in the sequence E-I-E-I. For between 25° and 90°, hinges A, B and C alternate between the intrados and the extrados for every value of imposed displacements. According to the value of considered, either minor and distributed openings or fully developed hinges occur at the right haunch at the intrados. The intrados hinges A and C move upwards towards the crown as the right support moves. For values of up to 75°, collapse is governed by an asymmetrical four-hinge mechanisms with hinge located according to the sequence E-I-E-I. For equal to 90°, the arch collapses by an almost symmetrical five-hinge mechanism (sequence E-I-E-I-E), since two hinges occur at the arch springings. It is interesting to observe that for up to 15° the arch response is governed by the vertical component of the imposed displacement, as the hinge configuration is the same as the one obtained for purely vertical displacements ( = 0°). For equal or larger than 25°, the hinge configuration is driven by the horizonal component, since hinges alternate between intrados and extrados, like in case of purely horizontal displacements ( = 90°). For equal to 20°, a transition between the two previous hinge configurations occurs.
226 APPENDIX B Analysis of the displacements of the voussoirs Figure 17 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 18 Vertical displacement z,v of the voussoirs, net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 15°.
APPENDIX B 227 a) b ) c) Figure 19 Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 15°: a) markers 1e-14e, b) markers 25i-33i and c) markers 55i-RS (right support), to detect the opening of hinges A, B and C, respectively. dv [mm] dv [mm] dv [mm]
228 APPENDIX B Support reaction – displacement curves a) b) Figure 20 Support reaction-displacement curves at the right and left supports for = 15°: a) curves horizontal reaction Rx/W vs. deflection ratio z/L, b) curves vertical reaction Rz/W vs. deflection ratio z/L. 012345678910 z /L [%] 32 34 36 38 40 42 Rx/W [%] Right support Left support 012345678910 z /L [%] 40 44 48 52 56 60 Rz/W [%] Right support Left support
APPENDIX B 229 TEST PERFORMED FOR = 20° Evolution of the damage configuration a) b ) c) d) e) f) Figure 21 Damage evolution for = 20°: a) z/L = 1.9%, b) z/L = 3.8%, c) z/L = 5.6%, d) z/L = 8.4%, e) collapse for z/L = 9.1%, f) unstable configuration corresponding to z/L = 9.1%.
230 APPENDIX B Analysis of the displacements of the voussoirs Figure 22 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 23 Vertical displacement z,v of the voussoirs, net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 20°. 012345678910 z /L [%] -3 -2 -1 0 1 2 3 4
APPENDIX B 231 a) b) c) Figure 24 Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 20°: a) markers 1e-14e, b) markers 25i-33i and c) markers 37e-51e, to detect the opening of hinges A, B and C, respectively.
232 APPENDIX B Support reaction – displacement curves a) b) Figure 25 Support reaction-displacement curves at the right and left supports for = 20°: a) curves horizontal reaction Rx/W vs. deflection ratio z/L, b) curves vertical reaction Rz/W vs. deflection ratio z/L. 012345678910 z /L [%] 32 34 36 38 40 42 44 Rx/W [%] Right support Left support 012345678910 z /L [%] 38 42 46 50 54 58 62 Rz/W [%] Right support Left support
APPENDIX B 233 TEST PERFORMED FOR = 25° Evolution of the damage configuration a) b ) c) d) e) f) Figure 26 Damage evolution for = 25°: a) z/L = 2.8%, b) z/L = 3.8%, c) z/L = 4.7%, d) z/L = 5.6%, e) collapse for z/L = 7.6%, f) unstable configuration corresponding to z/L = 7.6%.
234 APPENDIX B Analysis of the displacements of the voussoirs Figure 27 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 28 Vertical displacement z,v of the voussoirs, net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 25°. 012345678910 z /L [%] -2 -1 0 1 2 3 4 5 6
APPENDIX B 235 a) b ) c) Figure 29 Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 25°: a) markers 1e-14e, b) markers 25i-33i and c) markers 37e-51e, to detect the opening of hinges A, B and C, respectively.
242 APPENDIX B Analysis of the displacements of the voussoirs Figure 37 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 38 Vertical displacement z,v of the voussoirs, net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 35°. 0123456 z /L [%] -2 0 2 4 6 8 10 12
APPENDIX B 243 a) b ) c) Figure 39 Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 35°: a) markers 1e-14e, b) markers 25i-33i and c) markers 37e-51e, to detect the opening of hinges A, B and C, respectively.
244 APPENDIX B Support reaction – displacement curves a) b) Figure 40 Support reaction-displacement curves at the right and left supports for = 35°: a) curves horizontal reaction Rx/W vs. deflection ratio z/L, b) curves vertical reaction Rz/W vs. deflection ratio z/L. 0123456 z /L [%] 30 32 34 36 38 40 42 44 46 Rx/W [%] Right support Left support 0123456 z /L [%] 34 38 42 46 50 54 58 62 66 Rz/W [%] Right support Left support
APPENDIX B 245 TEST PERFORMED FOR = 40° Evolution of the damage configuration a) b ) c) d) e) f) Figure 41 Damage evolution for = 40°: a) z/L = 0.9%, b) z/L = 1.9%, c) hinge movement for z/L = 3.5%, e) collapse for z/L = 4.4%, f) unstable configuration corresponding to z/L = 4.4%.
246 APPENDIX B Analysis of the displacements of the voussoirs Figure 42 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 43 Vertical displacement z,v of the voussoirs, net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 40°. 012345 z /L [%] -2 0 2 4 6 8 10 12 14
APPENDIX B 247 a) b ) c) Figure 44 Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 40°: a) markers 1e-14e, b) markers 25i-33i and c) markers 37e-51e, to detect the opening of hinges A, B and C, respectively.
248 APPENDIX B Support reaction – displacement curves a) b) Figure 45 Support reaction-displacement curves at the right and left supports for = 40°: a) curves horizontal reaction Rx/W vs. deflection ratio z/L, b) curves vertical reaction Rz/W vs. deflection ratio z/L. 012345 z /L [%] 32 34 36 38 40 42 44 Rx/W [%] Right support Left support 012345 z /L [%] 38 42 46 50 54 58 62 Rz/W [%] Right support Left support
APPENDIX B 249 TEST PERFORMED FOR = 45° Evolution of the damage configuration a) b ) c) d) e) f) Figure 46 Damage evolution for = 45°: a) z/L = 1.9%, b) hinge movement for z/L = 2.9%, c) z/L = 3.2%, d) hinge movement (just before collapse) for z/L = 3.7%, e) collapse for z/L = 3.7%, f) unstable configuration corresponding to z/L = 3.7%.
250 APPENDIX B Analysis of the displacements of the voussoirs Figure 47 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 48 Vertical displacement z,v of the voussoirs, net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 45°. 012345 z /L [%] -2 0 2 4 6 8 10 12 14 16
APPENDIX B 251 a) b ) c) Figure 49 Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 45°: a) markers 1e-14e, b) markers 25i-33i and c) markers 37e-51e, to detect the opening of hinges A, B and C, respectively.
258 APPENDIX B Analysis of the displacements of the voussoirs Figure 57 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 58 Vertical displacement z,v of the voussoirs, net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 75°. 0 0.2 0.4 0.6 0.8 1 1.2 z /L [%] -4 0 4 8 12 16 20 24
APPENDIX B 259 a) b) c) Figure 59 Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L) for = 75°: a) markers 1e-14e, b) markers 25i-33i and c) markers 37e-51e, to detect the opening of hinges A, B and C, respectively.
260 APPENDIX B Support reaction – displacement curves a) b) Figure 60 Support reaction-displacement curves at the right and left supports for = 75°: a) curves horizontal reaction Rx/W vs. deflection ratio z/L, b) curves vertical reaction Rz/W vs. deflection ratio z/L. 0 0.2 0.4 0.6 0.8 1 1.2 z /L [%] 32 34 36 38 40 42 44 46 48 Rx/W [%] Right support Left support 0 0.2 0.4 0.6 0.8 1 1.2 z /L [%] 42 44 46 48 50 52 54 56 58 Rz/W [%] Right support Left support
APPENDIX B 261 TEST PERFORMED FOR = 90° Evolution of the damage configuration a) b ) c) d) e) f) Figure 61 Damage evolution for = 90°: a) x/L = 2.8%, b) x/L = 3.2%, c) x/L = 3.4%, d) hinge movement for x/L = 3.7%, e) collapse for x/L = 3.7%, f) unstable configuration corresponding to x/L = 3.7%.
262 APPENDIX B Support reaction – displacement curves a) b) Figure 62 Support reaction-displacement curves at the right and left supports for = 90°: a) curves horizontal reaction at the right support Rx/W vs. span increase x/L, b) curves vertical reaction at the right support Rz/W vs. span increase x/L.
263 APPENDIX C EXPERIMENTAL VS. NUMERICAL RESULTS
264 APPENDIX C TEST PERFORMED FOR = 0° Evolution of the damage configuration a) b) c) d) Figure 63 Damage evolution for = 0°. Numerical model (kn = 3 N/mm3, left) vs. experimental model (right): a) z/L = 6.6%, b) z/L = 9.4%, c) z/L = 12.2%, d) collapse for z,u/L = 16.5% in the numerical model and z,u/L = 16.5% in the experimental model.
APPENDIX C 265 Analysis of the displacements of the voussoirs Figure 64 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 65 Comparison between numerical results (kn = 3 N/mm3, left) and experimental results (right) for = 0°. Vertical displacement z,v of the voussoirs, net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L). 0 2 4 6 8 10 12 14 16 18 z /L [%] -35 -30 -25 -20 -15 -10 -5 0 5
266 APPENDIX C a) b ) c) Figure 66 Comparison between numerical (left) and experimental (right) results for = 0°. Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 55l-RS (right support), to detect the opening of hinges A, B and C, respectively. dv [mm]dv [mm]dv [mm]
APPENDIX C 267 Support reaction – displacement curves a) b) Figure 67 Comparison between FE predictions (for kn = 3 N/mm3 and kn = 48 N/mm3) and experimental results for = 0°: a) curves horizontal reaction at the right support Rx/W vs. deflection ratio z/L, b) curves vertical reaction at the right support Rz/W vs. deflection ratio z/L.
274 APPENDIX C a) b ) c) Figure 76 Comparison between numerical (left) and experimental (right) results for = 10°. Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 55l-RS (right support), to detect the opening of hinges A, B and C, respectively. dv [mm]dv [mm]dv [mm]
APPENDIX C 275 Support reaction – displacement curves a) b) Figure 77 Comparison between FE predictions (for kn = 3 N/mm3 and kn = 48 N/mm3) and experimental results for = 10°: a) curves horizontal reaction at the right support Rx/W vs. deflection ratio z/L, b) curves vertical reaction at the right support Rz/W vs. deflection ratio z/L.
276 APPENDIX C TEST PERFORMED FOR = 15° Evolution of the damage configuration a) b) c) d) Figure 78 Damage evolution for = 15°. Numerical model (kn = 3 N/mm3, left) vs. experimental model (right): a) z/L = 2.8%, b) z/L = 4.7%, c) z/L = 6.6%, d) collapse for z,u/L = 8.7% in the numerical model and z,u/L = 9.1% in the experimental model.
APPENDIX C 277 Analysis of the displacements of the voussoirs Figure 79 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 80 Comparison between numerical results (kn = 3 N/mm3, left) and experimental results (right) for = 15°. Vertical displacement z,v of the voussoirs, net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L). z,v [mm]
278 APPENDIX C a) b ) c) Figure 81 Comparison between numerical (left) and experimental (right) results for = 15°. Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 55l-RS (right support), to detect the opening of hinges A, B and C, respectively. dv [mm] dv [mm] dv [mm] dv [mm] dv [mm] dv [mm]
APPENDIX C 279 Support reaction – displacement curves a) b) Figure 82 Comparison between FE predictions (for kn = 3 N/mm3 and kn = 48 N/mm3) and experimental results for = 15°: a) curves horizontal reaction at the right support Rx/W vs. deflection ratio z/L, b) curves vertical reaction at the right support Rz/W vs. deflection ratio z/L. 0 2 4 6 8 10 12 14 16 z /L [%] 32 34 36 38 40 42 44 46 Rx/W [%] FEM_kn= 48 FEM_kn= 3 Exp 0 2 4 6 8 10121416 z /L [%] 45 47 49 51 53 55 57 59 Rz/W [%] FEM_kn= 48 FEM_kn= 3 Exp
280 APPENDIX C TEST PERFORMED FOR = 20° Evolution of the damage configuration a) b) c) d) Figure 83 Damage evolution for = 20°. Numerical model (kn = 3 N/mm3, left) vs. experimental model (right): a) z/L = 0.6%, b) z/L = 2.3%, c) z/L = 5.6%, d) collapse for z,u/L = 9.6% in the numerical model and z,u/L = 9.1% in the experimental model.
APPENDIX C 281 Analysis of the displacements of the voussoirs Figure 84 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 85 Comparison between numerical results (kn = 3 N/mm3, left) and experimental results (right) for = 20°. Vertical displacement z,v of the voussoirs, net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L). 012345678910 z /L [%] -3 -2 -1 0 1 2 3 4 012345678910 z /L [%] -3 -2 -1 0 1 2 3 4
282 APPENDIX C a) b ) c) Figure 86 Comparison between numerical (left) and experimental r(right) results for = 20°. Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 37e-51e, to detect the opening of hinges A, B and C, respectively. dv [mm]dv [mm] dv [mm]
APPENDIX C 283 Support reaction – displacement curves a) b) Figure 87 Comparison between FE predictions (for kn = 3 N/mm3 and kn = 48 N/mm3) and experimental results for = 20°: a) curves horizontal reaction at the right support Rx/W vs. deflection ratio z/L, b) curves vertical reaction at the right support Rz/W vs. deflection ratio z/L. 0 2 4 6 8 10 12 14 16 z /L [%] 32 34 36 38 40 42 44 46 Rx/W [%] FEM_kn= 48 FEM_kn= 3 Exp 0 2 4 6 8 10121416 z /L [%] 45 47 49 51 53 55 57 59 Rz/W [%] FEM_kn= 48 FEM_kn= 3 Exp
290 APPENDIX C a) b ) c) Figure 96 Comparison between numerical (left) and experimental (right) results for = 30°. Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 37e-51e, to detect the opening of hinges A, B and C, respectively. dv [mm]dv [mm] dv [mm]
APPENDIX C 291 Support reaction – displacement curves a) b) Figure 97 Comparison between FE predictions (for kn = 3 N/mm3 and kn = 48 N/mm3) and experimental results for = 30°: a) curves horizontal reaction at the right support Rx/W vs. deflection ratio z/L, b) curves vertical reaction at the right support Rz/W vs. deflection ratio z/L.
292 APPENDIX C TEST PERFORMED FOR = 35° Evolution of the damage configuration a) b) c) d) Figure 98 Damage evolution for = 35°. Numerical model (kn = 3 N/mm3, left) vs. experimental model (right): a) z/L = 1.3%, b) z/L = 3.4%, c) z/L = 3.6%, d) collapse for z,u/L = 5.6% in the numerical model and z,u/L = 5.5% in the experimental model.
APPENDIX C 293 Analysis of the displacements of the voussoirs Figure 99 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 100 Comparison between numerical results (kn = 3 N/mm3, left) and experimental results (right) for = 35°. Vertical displacement z,v of the voussoirs, net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L). 0123456 z /L [%] -2 0 2 4 6 8 10 12
294 APPENDIX C a) b ) c) Figure 101 Comparison between numerical (left) and experimental (right) results for = 35°. Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 55l-RS (right support), to detect the opening of hinges A, B and C, respectively. dv [mm]dv [mm] dv [mm]
APPENDIX C 295 Support reaction – displacement curves a) b) Figure 102 Comparison between FE predictions (for kn = 3 N/mm3 and kn = 48 N/mm3) and experimental results for = 35°: a) curves horizontal reaction at the right support Rx/W vs. deflection ratio z/L, b) curves vertical reaction at the right support Rz/W vs. deflection ratio z/L. 0246810 z /L [%] 30 32 34 36 38 40 42 44 46 48 50 Rx/W [%] FEM_kn= 48 FEM_kn= 3 Exp 0246810 z /L [%] 42 44 46 48 50 52 54 56 58 60 62 Rz/W [%] FEM_kn= 48 FEM_kn= 3 Exp
296 APPENDIX C TEST PERFORMED FOR = 40° Evolution of the damage configuration a) b) c) d) Figure 103 Damage evolution for = 40°. Numerical model (kn = 3 N/mm3, left) vs. experimental model (right): a) z/L = 1.7%, b) z/L = 2.6%, c) z/L = 3.4%, d) collapse for z,u/L = 4.5% in the numerical model and z,u/L = 4.4% in the experimental model.
APPENDIX C 297 Analysis of the displacements of the voussoirs Figure 104 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 105 Comparison between numerical results (kn = 3 N/mm3, left) and experimental results (right) for = 40°. Vertical displacement z,v of the voussoirs, net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L). 012345 z /L [%] -2 0 2 4 6 8 10 12 14
298 APPENDIX C a) b ) c) Figure 106 Comparison between numerical (left) and experimental (right) results for = 40°. Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 55l-RS (right support), to detect the opening of hinges A, B and C, respectively. dv [mm]dv [mm] dv [mm]
APPENDIX C 299 Support reaction – displacement curves a) b) Figure 107 Comparison between FE predictions (for kn = 3 N/mm3 and kn = 48 N/mm3) and experimental results for = 40°: a) curves horizontal reaction at the right support Rx/W vs. deflection ratio z/L, b) curves vertical reaction at the right support Rz/W vs. deflection ratio z/L. 02468 z /L [%] 30 32 34 36 38 40 42 44 46 48 50 Rx/W [%] FEM_kn= 48 FEM_kn= 3 Exp 02468 z /L [%] 42 44 46 48 50 52 54 56 58 60 62 Rz/W [%] FEM_kn= 48 FEM_kn= 3 Exp
306 APPENDIX C a) b ) c) Figure 116 Comparison between numerical (left) and experimental (right) results for = 60°. Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 55l-RS (right support), to detect the opening of hinges A, B and C, respectively. dv [mm]dv [mm] dv [mm]
APPENDIX C 307 Support reaction – displacement curves a) b) Figure 117 Comparison between FE predictions (for kn = 3 N/mm3) and experimental results for = 60°: a) curves horizontal reaction at the right support Rx/W vs. deflection ratio z/L, b) curves vertical reaction at the right support Rz/W vs. deflection ratio z/L. 0 0.5 1 1.5 2 2.5 3 z /L [%] 32 34 36 38 40 42 44 46 Rx/W [%] FEM_kn= 3 Exp 0 0.5 1 1.5 2 2.5 3 z /L [%] 42 44 46 48 50 52 54 56 Rz/W [%] FEM_kn= 3 Exp
308 APPENDIX C TEST PERFORMED FOR = 75° Evolution of the damage configuration a) b) c) d) Figure 118 Damage evolution for = 75°. Numerical model (kn = 3 N/mm3, left) vs. experimental model (right): a) z/L = 0.4%, b) z/L = 0.7%, c) z/L = 0.8%, d) collapse for z,u/L = 1.0% in the numerical model and z,u/L = 1.0% in the experimental model.
APPENDIX C 309 Analysis of the displacements of the voussoirs Figure 119 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 120 Comparison between numerical results (kn = 3 N/mm3, left) and experimental results (right) for = 75°. Vertical displacement z,v of the voussoirs, net of the imposed vertical displacement z, vs. imposed vertical displacement (expressed in terms of deflection ratio z/L). 0 0.2 0.4 0.6 0.8 1 1.2 z /L [%] -4 0 4 8 12 16 20 24
310 APPENDIX C a) b ) c) Figure 121 Comparison between numerical (left) and experimental (right) results for = 75°. Change in the distance between markers of adjacent voussoirs, dv , vs. imposed vertical displacement (expressed in terms of deflection ratio z/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 55l-RS (right support), to detect the opening of hinges A, B and C, respectively. dv [mm]dv [mm] dv [mm]
APPENDIX C 311 Support reaction – displacement curves a) b) Figure 122 Comparison between FE predictions (for kn = 3 N/mm3) and experimental results for = 75°: a) curves horizontal reaction at the right support Rx/W vs. deflection ratio z/L, b) curves vertical reaction at the right support Rz/W vs. deflection ratio z/L. 0 0.2 0.4 0.6 0.8 1 1.2 z /L [%] 32 34 36 38 40 42 44 46 48 Rx/W [%] FEM_kn= 3 Exp 0 0.2 0.4 0.6 0.8 1 1.2 z /L [%] 42 44 46 48 50 52 54 56 58 Rz/W [%] FEM_kn= 3 Exp
312 APPENDIX C TEST PERFORMED FOR = 90° Evolution of the damage configuration a) b) c) d) Figure 123 Damage evolution for = 90°. Numerical model (kn = 3 N/mm3, left) vs. experimental model (right): a) x/L = 1.9%, b) x/L = 2.6%, c) x/L = 3.4%, d) collapse for x,u/L = 4.0% in the numerical model and x,u/L = 3.7% in the experimental model.
APPENDIX C 313 Analysis of the displacements of the voussoirs Figure 124 Identification of the markers considered to analyse the evolution of the vertical displacements of the voussoirs (Δz,v) and the change in the distance between adjacent voussoirs (Δdv) with respect to the initial distance dv,0. Figure 125 Numerical results (kn = 3 N/mm3) for = 90°. Vertical displacement z,v of the voussoirs vs. imposed horizontal displacement (expressed in terms of span increase x/L).
314 APPENDIX C a) b ) c) Figure 126 Numerical results for = 90°. Change in the distance between markers of adjacent voussoirs, dv , vs. imposed horizontal displacement (expressed in terms of span increase x/L): a) markers 1e-14e, b) markers 25i-33i and c) markers 55l-RS (right support), to detect the opening of hinges A, B and C, respectively. dv [mm]dv [mm] dv [mm]
APPENDIX C 315 Support reaction – displacement curves a) b) Figure 127 Comparison between FE predictions (for kn = 3 N/mm3 and kn = 48 N/mm3) and experimental results for = 90°: a) curves horizontal reaction at the right support Rx/W vs. span increase x/L, b) curves vertical reaction at the right support Rz/W vs. span increase x/L. 0123456 x/L [%] 25 30 35 40 45 50 55 FEM_kn= 48 FEM_kn= 3 Exp