scieee AI-readable full text Open interactive document viewer

Photodegradation and sorption govern tetracycline removal during wastewater treatment in algal ponds

Norvilla, Zane N.,Toledo Cervantes, Alma,Blanco, Saúl,Shilton, Andy,Guieysse, Benoit,Muñoz Torre, Raúl

Abstract

Producción Científica

Full text

Photodegradation and sorption govern tetracycline removal during wastewater treatment in 1 algal ponds 2 Norvill, Zane N.a, b; Toledo-Cervantes, Almaa; Blanco, Saulc; Shilton, Andyb; Guieysse, 3 Benoitb; Muñoz, Raula* 4 a Department of Chemical Engineering and Environmental Technology, University of 5 Valladolid, Dr. Mergelina s/n, Valladolid 47011, Spain 6 b School of Engineering and Advanced Technology, Massey University, Private Bag 11 7 222, Palmerston North 4442, New Zealand 8 c The Institute of the Environment, La Serna, 58, 24007 Leon, Spain 9 *Corresponding author: [email protected]10 1 Abstract 11 The degradation of the antibiotic tetracycline, supplied at 100 µg L-1 in domestic 12 wastewater, was studied in an outdoor, pilot scale, high rate algal pond (HRAP). Effective 13 operation was demonstrated with the biomass concentration and the chemical oxygen 14 demand removal efficiency averaging 1.2 ± 0.1 gTSS L-1 and 80 ± 4%, respectively, across 15 all operational periods. Tetracycline removal exceeded 93% and 99% when the HRAP was 16 operated at hydraulic retention times of 4 and 7 days, respectively. Batch tests and pulse 17 testing during HRAP operation repeatedly evidenced the significance of photodegradation 18 as a removal mechanism. Sorption dominated tetracycline removal during the night, but 19 accounted for less than 6% of the total pollutant removal based on sorbed tetracycline 20 extracted from biomass. Overall, these results provide the first demonstration of efficient 21 antibiotic removal, occurring mainly via indirect photodegradation, during relevant HRAP 22 operation (low pollutant concentration, domestic wastewater and natural sunlight). 23 24 Keywords: Emerging pollutant; microalgae; raceway; photolysis; wastewater 25 2 1. Introduction 26 Antibiotics are emerging pollutants of particular concern due to their widespread use in 27 human and animal medicine (González-Zorn and Escudero, 2012; Lupo et al., 2012). Total 28 global antibiotic use in 2010 exceeded 70 billion standard units (i.e. tablets) for human 29 consumption (Gelband et al., 2015), and over 63,000 tonnes were used for livestock 30 production (Van Boeckel et al., 2015). Since 60-90% of the administered antibiotic dose is 31 commonly excreted in urine/faeces, antibiotics are therefore ubiquitous in wastewater 32 (Hirsch et al., 1999; Sarmah et al., 2006). Conventional biological wastewater treatment 33 (WWT) technologies (e.g. activated sludge, nitrification/denitrification systems) are not 34 designed to target antibiotic removal specifically, often leading to the release of antibiotics 35 to the environment, depending on the specific antibiotic and WWT system (Leung et al., 36 2012; Michael et al., 2013; Zhang and Li, 2011; Norvill et al. 2016). This release is 37 suspected to be contributing to the increase of antibiotic resistance, which is a major human 38 health risk (Aminov, 2009; Daghrir and Drogui, 2013; Gullberg et al., 2011). There are also 39 environmental risks associated with the uncontrolled discharge of antibiotics, as the 40 presence of antibiotics can alter microbial ecology and their ecological functions (Aminov, 41 2009; Daghrir and Drogui, 2013; Ding and He, 2010). 42 43 Algal based WWT by high rate algal ponds (HRAPs) is an emerging technology receiving 44 increasing interest due to its energy efficient operation and resource recovery potential via 45 carbon and nutrient assimilation into biomass production. In HRAPs, the removal of 46 macropollutants (C, N, P) and the biomass production potential are now relatively well-47 3 characterized (Park et al., 2013, 2011; Posadas et al., 2015a; Sutherland et al., 2014), but 48 for HRAP, and indeed all algal WWT, there is scarce research on the fate of emerging 49 pollutants, especially antibiotics (de Godos et al., 2012; Hijosa-Valsero et al., 2010; 50 Matamoros et al., 2015). As with activated sludge, algal WWT systems are not designed 51 specifically for emerging pollutant removal, but these systems present a number of unique 52 characteristics compared to conventional municipal WWT systems (e.g. activated sludge), 53 which may enhance antibiotic removal (Norvill et al., 2016). In particular, HRAPs are i) 54 operated at long hydraulic residence times (HRT; several days rather than hours) allowing 55 time for antibiotic removal by mechanisms with slow kinetics; ii) designed with high 56 surface-area-to-volume ratios leading to high sunlight exposure and potential antibiotic 57 removal by photodegradation; while also enabling iii) the co-existence of phototrophic, 58 chemoorganotrophic and chemolithotrophic metabolisms supporting a broader catabolic 59 potential for antibiotic biodegradation; iv) the co-existence of autotrophic and heterotrophic 60 microorganisms enhancing biomass productivity and thus a potentially high antibiotic 61 removal capacity by sorption; and v) daily variations in dissolved oxygen concentration and 62 pH levels as a result of photosythetic activity, which may affect antibiotic removal 63 mechanisms by changing the redox conditions or antibiotic structure. Specific research is 64 therefore required given the complexity and specificity of the removal mechanisms and 65 parameters potentially involved. 66 67 TET, of which tens of thousands of tonnes are produced worldwide annually, was selected 68 as the target antibiotic (Daghrir and Drogui, 2013). Recent research by de Godos et al. 69 (2012) investigated the removal of tetracycline (TET) in lab-scale HRAPs and concluded 70 4 that photodegradation and sorption were the main TET removal mechanisms, with 71 insignificant biodegradation observed. However, the relevance of this work was limited, as 72 synthetic wastewater, artificial light and a mono-algal culture of Chlorella vulgaris was 73 used in their experimental design. On the other hand, TET may be biodegraded by bacteria 74 under nitrifying conditions (Song et al., 2015), and Dzomba et al. (2015) reported that TET 75 was biodegraded by four axenic algae cultures of Pseudokirchnerilla subcapitata, 76 Selenastrum capricornutum, Haematoloccus pluvialis and Chlorella sp.. Since mixed algal-77 bacterial cultures (typically encountered in outdoors HRAPs) can behave very differently to 78 bacterial nitrifying sludge or mono-cultured algae (Subashchandrabose et al., 2013), 79 specific research is therefore required to investigate TET removal in HRAPs. 80 81 In this context, the aim of this paper was to investigate the fate of tetracycline (TET) during 82 outdoor continuous operation of a pilot HRAP treating real domestic wastewater. The 83 influence of the presence of TET on the WWT performance of the HRAP was also 84 investigated. Additionally, batch experiments and pulse TET tests in the pilot HRAP were 85 carried out in order to identify the relative contribution of potential removal mechanisms 86 (photodegradation, biodegradation, sorption, and hydrolysis). 87 88 2. Materials and Methods 89 2.1 Chemicals 90 Analytical grade TET (>98%) was purchased from Sigma Aldrich (Spain). HPLC-grade 91 acetonitrile (ACN), formic acid (85%) and the rests of the chemicals (reagent grade) were 92 purchased from PANREAC (Barcelona, Spain). 93 5 94 2.2 Batch experiments 95 TET removal was studied in 2.5 L ‘batch reactors’ (open-top plastic tanks magnetically 96 stirred at 250 rpm, 185 mm surface diameter and 145 mm liquid depth) supplied with algal-97 bacterial biomass sourced from the pilot HRAP described in Section 2.3. The biomass was 98 sourced from the HRAP during stable operation with TET-spiked influent. Therefore, the 99 biomass was acclimatized to the presence of TET. TET was added to the cultivation broth 100 from a 100 mg L-1 aqueous stock solution and the broth was vigorously mixed for 30 101 seconds before sampling. TET concentration, pH, photosynthetic active radiation (PAR), 102 dissolved oxygen (DO) concentration and temperature were recorded at each sampling 103 time. The total suspended solids (TSS) concentration was measured for each batch reactor 104 at the end of the experiment. These batch experiments were conducted with initial TET 105 concentrations of 2 mg L-1 for ease of analysis, with the lower-concentration tests in the 106 pilot HRAP performed using the more time-consuming and expensive SPE analysis. Three 107 separate experiments were conducted to elucidate the mechanisms underlying TET removal 108 in algal-bacterial systems, as detailed below: 109 110 2.2.1 TET removal during full-day outdoor test 111 To elucidate the relative contribution of photodegradation, biodegradation, sorption and 112 hydrolysis on TET removal in the presence of algal-bacterial biomass, TET removal was 113 investigated in the presence of either active biomass or dead biomass (autoclaved at 121°C 114 for 20 min) during full-day outdoor tests (diurnal light exposure). An additional batch 115 reactor with TET in ultrapure (MQ) water was used as a control. The batch reactors were 116 6 positioned beside the pilot HRAP and therefore subjected to the same climatic conditions. 117 Following TET addition (2 mg L-1 initial concentration), the batch reactors were monitored 118 for 22 hours: twice in the first evening, twice the next morning before direct sunlight and 119 every two hours throughout the day. 120 121 2.2.2 TET sorption to biomass at different TET concentrations 122 To investigate TET sorption under dark conditions, the batch reactors were filled with 2.25 123 L of active algal-bacterial biomass, a variable volume of TET stock solution required to set 124 the different initial concentrations of TET (0.2, 0.5, 1, 2, 5, and 10 mg L-1), and MQ to 125 reach a final total volume of 2.5 L. The batch reactors were incubated at 20 ± 3 °C and TET 126 concentration was monitored over 14 hours (0, 0.5, 1, 4, and 14 h). Biomass samples (40 127 mL) were taken after 4 hours and 14 h of incubation and subsequently extracted (see 128 Section 2.4) to quantify the amount of TET sorbed onto biomass. 129 130 2.2.3 Influence of pH on TET removal 131 The effect of pH on TET removal was investigated in the presence of active algal-bacterial 132 biomass under dark conditions at 20 ± 3°C. Three batch reactors were adjusted to pH 6, 8.5 133 and 10.5 before sampling, using 0.1 M HCl or 0.1 M NaOH solution. These pH values were 134 chosen according to the pKa values of TET (the two upper pKa values are 7.8 and 9.6; 135 Qiang and Adams, 2004). Although our pilot HRAP did not reach as high as pH 10.5 (see 136 Section 3.2.1), the pH in other HRAPs can typically attain values of 11 during peak solar 137 hours (Norvill et al., 2016). Two batch reactors, one with the same biomass but without pH 138 7 adjustment (pH 6.5-6.8) and the other filled with MQ water, served as controls. The batch 139 reactors were monitored over 4 hours (0, 1, 2, and 4 h). 140 141 2.3 Continuous wastewater treatment in HRAP 142 The 180 L oval pilot HRAP was constructed in PVC (L×W×D = 1.7 m × 0.82 m × 0.25), 143 with a central wall and mid-channel baffles at each end (Figure S1, Supporting 144 Information). A paddle wheel (6 blades, 10.5 rpm) supported a mid-channel velocity of the 145 cultivation broth of 0.2 m s-1 according to Park et al. (2011). The HRAP was located 146 outdoors at the Department of Chemical Engineering and Environmental Technology of the 147 University of Valladolid (Spain, Mediterranean climate). The HRAP was inoculated with 148 1.5 L of 23 gTSS L-1 settled biomass taken from an indoor HRAP of similar design (Posadas 149 et al., 2015b). 150 151 2.3.1 Continuous HRAP operation 152 Fresh domestic wastewater was collected every 1-2 days from a pilot-scale pre-treatment 153 plant (1 mm rotary sieve followed by primary sedimentation) sourced from a municipal 154 sewer located nearby the Department of Chemical Engineering and Environmental 155 Technology at University of Valladolid, Spain. The pre-treated wastewater was stored at 4-156 6°C, mixed with a submergible pump and fed continuously into the HRAP using a 157 peristaltic pump. The HRAP effluent overflowed to an 8 L clarifier, where settled biomass 158 was removed twice weekly. Pond performance was monitored twice a week by measuring 159 the concentration of TSS and VSS (volatile suspended solids) in the HRAP, and the 160 influent and effluent concentrations of COD (chemical oxygen demand), TOC (total 161 8 organic carbon), TN (total nitrogen), dissolved nutrients (NO3-, NO2-, PO43-), TSS and VSS. 162 Daily influent and effluent flow rates were measured, and the daily net evaporation rates 163 determined. pH, DO concentration and temperature in the cultivation broth were recorded 164 online. The average sunlight irradiation during each operational stage is shown in Table 1. 165 166 The HRAP was operated at 7 d HRT for 52 days (Stage I) to establish a baseline HRAP 167 performance. TET was then supplied at 100 µg TET L-1 in the influent wastewater for 35 168 days at 7 d HRT (Stage II). The influent wastewater flow rate was increased in Stage III to 169 operate the HRAP at 4 d HRT under the same TET influent concentration for 17 days. The 170 4 d HRT was maintained during Stage IV for another 27 days in order to perform TET 171 pulse tests as described in Section 2.3.2. The 100 µg TET L-1 supplied in the influent 172 wastewater is a concentration typically found in wastewater from hospitals (Pena et al., 173 2010). During the pseudo-steady states of HRAP operation in Stages II and III (Table 1), 174 the aqueous TET concentration was monitored both in the mornings and evenings at least 175 twice weekly. Samples of algal-bacterial biomass (40 mL) were taken for analysis of sorbed 176 TET concentrations twice during each pseudo-steady state. 177 178 2.3.2 TET pulse tests during continuous HRAP operation 179 Several TET ‘pulse tests’ – adding 180 mL of 100 mg TET L-1 to the pilot HRAP – were 180 conducted during Stage IV in order to confirm the findings from the batch experiments 181 (Section 2.2) using lower initial TET concentrations. Each TET addition therefore 182 increased the TET concentration in the cultivation broth by 100 µg L-1. No TET was added 183 15 Supplementary Information Section S2.2 (Limousin et al., 2007). A preliminary sorption 321 test with autoclaved biomass compared to non-autoclaved biomass was also conducted 322 (data not shown). This preliminary test determined that the autoclaved biomass removed 323 less TET than the non-autoclaved biomass, but this difference was due to the lower sorption 324 capacity induced by autoclaving – the original TET was fully recovered by sorption 325 extraction analysis in both tests (Norvill, 2016). 326 327 3.1.3 Influence of pH on TET removal 328 A batch experiment was conducted to evaluate the effect of pH on TET removal in the 329 presence of active biomass under darkness. While TET removal was similar (Figure 2) in 330 experiments conducted at pH 6 and unadjusted-pH (pH ∼6.5-6.8), TET concentration 331 immediately decreased at pH of 8.5 and 10.5. This rapid TET removal occurred within 30 s 332 and was possibly due to hydrolysis, epimerization (other than 4epiTET) or sorption related 333 mechanisms. As this rapid drop brought TET concentrations near the quantification limit, 334 no subsequent observations could be made. A pH-mediated hydrolysis was hypothesized as 335 the main mechanism responsible for TET fate at high pH values. However, further 336 investigation is required to confirm the mechanisms affected by pH, which could be 337 especially important for HRAPs that reach pH up to 11 during the day (Norvill et al. 2016). 338 The average DO concentration and temperature recorded in the batch reactors with biomass 339 were 0.9 ± 0.1 mg L-1 and 19.4 ± 1.0 °C (n = 16), respectively. 340 341 16 3.2 Continuous wastewater treatment in HRAP 342 3.2.1 HRAP performance 343 COD and TOC removals ranging from 75 to 84% and 75 to 88%, respectively, were 344 recorded during all stages of operation (Table 2) while the removal of TN, PO43- and TSS 345 ranged from 40 to 66%, 31 to 59%, and 63 to 89%, respectively (Table 2). This data 346 showed that HRAP operation was efficient to its primary WWT purpose, with a similar 347 performance to other HRAPs operated with domestic wastewater (Park et al., 2013; 348 Posadas et al., 2015a). High HRAP concentrations of NO3- and NO2- were associated with 349 low TN removals (Table 2), either due to increased nitrification competitively limiting NH3 350 volatilization, or decreased denitrification allowing NO3- and NO2- accumulation (de Godos 351 et al., 2009; Ferrero et al., 2012; Sutherland et al., 2014). The removal of COD, TOC, and 352 inorganic carbon (IC) improved between Stage I and Stage II (Table 2), and these changes 353 were likely due to the stabilization of the algal and bacterial populations. 354 355 The decrease in HRT from 7 to 4 days (Stage II to Stage III) was associated with an 356 increase in biomass productivity from 4.5 ± 2.0 gTSS m-2 d-1 to 15.0 ± 1.7 gTSS m-2 d-1. The 357 lower productivity observed at 7 d HRT was likely due to IC limitation (algae consume 358 carbonates for growth) and higher biomass decay due to the increased cell residence time, 359 as the biomass concentration in the HRAP was similar at 7 and 4 d HRTs (Table 1). The 360 removals of COD, NH4+, TOC and TSS also decreased slightly from Stage II to Stage III as 361 HRT was decreased (Table 2). The decrease in TSS removal was attributed to the reduced 362 HRT in the clarifier and changes in biomass flocculation characteristics due to variations in 363 microalgae population structure. Changes in TET supply did not appear to cause 364 17 deterioration in HRAP performance, as most removal efficiencies increased or remained 365 similar between Stages I and II and between Stages III and IV. However, a decrease in 366 biomass settleability was recorded after the TET pulse tests were conducted (Section 3.2.3) 367 and TSS concentration in the clarifier thus decreased from ~15 g L-1 to ~ 5 g L-1 during 368 Stage IV, although the effluent TSS concentrations remain stable during Stages III and IV 369 (Table 2). de Godos et al. (2012) also reported biomass de-flocculation following TET 370 addition to a lab-scale HRAP, and this could impair biomass harvesting during full-scale 371 operation. Further analysis and data on HRAP performance, algal identification and 372 biomass composition are available in Section S3, Supporting Information, along with local 373 meteorological data. 374 375 3.2.2 Tetracycline removal during continuous operation 376 The experimentally measured TET influent concentration averaged 36 ± 2 µg L-1 (n = 8) 377 due to TET sorption to the suspended and colloidal solids present in wastewater. Since no 378 TET was detected in fresh wastewater samples, the TET removal efficiencies were 379 calculated based on theoretical influent concentration (aqueous + sorbed) of 100 µg TET L- 380 1. TET was removed below the 2 µg L-1 quantification limit (>99%, Figure 3) during 381 process operation at 7 d HRT (Stage II). The average effluent TET concentrations increased 382 up to 3.4 ± 0.2 µg L-1 (95% CI) when the HRT was decreased to 4 d, which corresponded to 383 97 ± 1 % removal. In comparison, the overall TET removal typically observed in activated 384 sludge WWT varies broadly (e.g. 32-85% (Batt et al., 2007); 10-85% (Plosz et al., 2010); 385 24-100% (Michael et al., 2013)). Based on dominant photodegradation observed during the 386 18 batch test results (Section 3.1.1), TET concentrations in the HRAP were expected to 387 decrease during daylight. Indeed, there was a statistically significant (p<0.01) difference 388 between TET concentrations in the morning (4.2 ± 0.5 µg L-1) and evening (2.5 ± 0.2 µg L- 389 1) when operated at 4 d HRT (Figure 3). 390 391 From the sorption extraction analysis the TET concentrations sorbed on the algal-bacterial 392 biomass were estimated to 4.0 µgTET gTSS-1 at 7 d HRT and 12.5 µgTET gTSS-1 at 4 d HRT.. 393 Using the average biomass productivities recorded during Stages II and III (Table 1), TET 394 removal by sorption was calculated at 0.9% and 5.3% of the overall TET removal recorded 395 at 7 d HRT and 4 d HRT operation, respectively. This HRAP was operated with HRT equal 396 to SRT (sludge retention time). However, SRT can be increased via biomass recycling 397 (Park et al. 2013), which may have indirect effect on TET sorption, by altering the 398 productivity or the structure of the algal-bacterial population, the latter impacting the 399 biomass sorption properties. 400 401 A linear partition coefficient approximation (Kd = [sorbed]/ [aqueous TET]) is often used to 402 describe the sorption isotherm at equilibrium at low TET concentrations (Limousin et al., 403 2007). Since aqueous TET concentrations were below the quantification limit during 7 d 404 HRT operation, a partition coefficient was only calculated during 4 d HRT operation. Kd 405 values in the range of 2.8-4.5 L g-1 were thus recorded during Stage III: these values were 406 higher than those achieved in the sorption batch tests performed during Stage IV (Kd = 0.5 - 407 2.2 L g-1, Table S2, Supplementary Information), but comparable to previously reported 408 results in lab-scale HRAPs (Kd = 4.2 ± 0.2 L g-1; de Godos et al., 2012). In comparison, Kd 409 19 values reported for TET sorption on activated sludge range from 0.47 to 8.4 L g-1 (Kim et 410 al., 2005; Plósz et al., 2010; Prado et al., 2009). In view of the variabilities reported, the 411 sorption characteristics of algal-bacterial biomass can be considered as similar to the 412 sorption characteristics on the biomass generated during conventional biological treatment 413 (e.g. activated sludge processes). No adverse effects on the algae activity (observed by 414 daily pH and DO fluctuations) or the HRAP performance were noticed during continuous 415 HRAP operation with TET added to the influent wastewater. 416 417 As WWT in HRAPs generates considerably more biomass than conventional biological 418 WWT, HRAP WWT should also provide a larger sorption capacity for removing 419 hydrophobic pollutants (Norvill et al., 2016). A high sorption capacity may enable the 420 attenuation of night shock loadings and the removal of hydrophobic pollutants recalcitrant 421 to photodegradation (experimental demonstration is required). However, where efficient 422 pollutant photodegradation is taking place, the results suggest that overall sorption will be 423 minimal (thus also minimizing sludge management hazards, as antibiotics can desorb from 424 the sludge) (Kim et al., 2005; Norvill et al., 2016). 425 426 3.2.3 Tetracycline pulses in the pilot HRAP 427 The pulses of TET concentration were rapidly mitigated, showing that pilot HRAP 428 operation was robust to fluctuations in TET influent load (Figure 4). TET was rapidly 429 removed during sunlight exposure after the first TET pulse and TET removal slowed after 430 5:00 pm when the HRAP was no longer exposed to direct sunlight. The second TET pulse 431 induced under dark conditions was also followed by a rapid disappearance of the aqueous 432 20 TET, but then TET concentrations stabilized around 30 µg L-1 overnight. TET removal 433 subsequently accelerated when the HRAP was exposed to direct sunlight the second day 434 (Figure 4). Based on the batch test results discussed in Section 3.1, the removal after the 435 first TET pulse was due to a combination of sorption and photodegradation but after the 436 second TET pulse sorption was the only applicable mechanism overnight, with TET 437 photodegradation beginning again the second day. 438 439 Based on the assumption that the HRAP was a well-mixed system, TET removal under 440 sunlight was best described by pseudo-first order kinetics (Table 3), measuring kinetic rates 441 between 11 am – 3 pm when the sunlight intensity was most consistent. Since sorption of 442 TET on the HRAP biomass had already approached equilibrium during the night, the rates 443 of TET removal recorded under sunlight during the second day were consistently lower 444 than the rates of TET removal recorded during the first day, when rapid TET removal by 445 both sorption and photodegradation occurred (Table 3). As photodegradation decreased 446 aqueous TET concentrations during sunlight exposure, desorption of TET from the biomass 447 likely occurred. Therefore, TET desorption likely explains the difference in the daytime 448 TET removal rates recorded during the first and second days of each pulse test. 449 450 A mathematical model developed to predict TET removal based on sorption and 451 photodegradation also demonstrated that photodegradation was directly proportional to the 452 recorded PAR (i.e. the pseudo-first order rates reported here were dependent on sunlight 453 intensity) (Norvill, 2016). The mathematical model was not included in this article due to 454 space limitations. 455 21 456 The comparison of TET removal rates against environmental variables (light, pH, DO, 457 temperature) revealed that the highest TET removal rates were associated with high DO 458 concentrations (>6.9 mg-O2 L-1), high pH (>7.1) and high PAR (>1343 µmol m-2 s-1) 459 (Figure S5, Supporting Information). While these 3 parameters are interdependent (high 460 light irradiance generally causes both pH and DO to increase due to photosynthesis), a 461 possible causality between DO concentrations and TET removal may be related to the 462 generation of reactive oxygen species in indirect photodegradation mechanisms (Sandvik et 463 al., 2000; Vaughan and Blough, 1998). Alternatively, a high pH may enhance TET removal 464 via change in the ionic state of TET (which has a pKa ~7.8; Qiang and Adams, 2004). 465 Direct photodegradation of TET has indeed been reported to increase at high pH, although 466 no research was found that investigated whether indirect TET photodegradation rates also 467 increase at high pH (Chen et al., 2008; López-Peñalver et al., 2010; Niu et al., 2013; 468 Wammer et al., 2011). The decreased biomass settleability after the initial pulse tests 469 (Section 3.2.1) may also have affected TET removal in the last three pulse experiments 470 (Table 3), via differences in light attenuation (algal floc disruption) and/or sorption 471 characteristics. The effect of pH and DO concentration upon the mechanisms of TET 472 removal in HRAP therefore requires further study. 473 474 4. Conclusions 475 Overall, TET was effectively removed during pilot HRAP operation at 7 d and 4 d HRT 476 under summer conditions, although the reliance on photodegradation may result in reduced 477 22 removal efficiencies during winter. These results provide the first demonstration in the 478 literature of efficient tetracycline removal during relevant HRAP operation outdoors (low 479 pollutant concentration and real wastewater) and indicate that algal based WWT provides 480 higher removal capacity (via indirect photodegradation and sorption) than conventional 481 biological WWT, although the removal of other antibiotics and emerging pollutants in 482 HRAPs must be assessed in further research. 483 484 5. Description of Supporting Information 485 The supporting information includes an image and schematic of the pilot HRAP operation, 486 the environmental conditions for the batch tests, mass balance calculations for the sorption 487 test, a comparison of sorption isotherm models used to describe the sorption near 488 equilibrium, tables of the monitored HRAP variables and the comparison of TET removal 489 rates with monitored environmental variables during the TET pulse tests. 490 491 6. Acknowledgements 492 This research was supported by MINECO (CTM2015-70442-R and Red Novedar), the 493 Regional Government of Castilla y León (Project VA024U14 and UIC 71) and INIA 494 (RTA2013-00056-C03-02). Zane Norvill was supported by a Massey University Doctoral 495 Scholarship. CONACyT-México is also gratefully acknowledged for the Postdoctoral grant 496 of Alma Toledo (No. Reg: 237873). 497 498 23 7. References 499 1. Aminov, R.I., 2009. The role of antibiotics and antibiotic resistance in nature. 500 Environ. Microbiol. 11, 2970–2988. doi:10.1111/j.1462-2920.2009.01972.x 501 2. Anderson, C.R., Rupp, H.S., Wu, W.H., 2005. Complexities in tetracycline analysis 502 - Chemistry, matrix extraction, cleanup, and liquid chromatography. J. Chromatogr. A 503 1075, 23–32. doi:10.1016/j.chroma.2005.04.013 504 3. Batt, A.L., Kim, S., Aga, D.S., 2007. Comparison of the occurrence of antibiotics in 505 four full-scale wastewater treatment plants with varying designs and operations. 506 Chemosphere 68, 428–435. doi:10.1016/j.chemosphere.2007.01.008 507 4. Beliakova, M.M., Bessonov, S.I., Sergeyev, B.M., Smirnova, I.G., Dobrov, E.N., 508 Kopylov, A.M., 2003. Rate of tetracycline photolysis during irradiation at 365 nm. 509 Biochem. 68, 182–187. doi:10.1023/A:1022697312042 510 5. Challis, J.K., Hanson, M.L., Friesen, K.J., Wong, C.S., 2014. A critical assessment 511 of the photodegradation of pharmaceuticals in aquatic environments: defining our current 512 understanding and identifying knowledge gaps. Environ. Sci. Process. Impacts 16, 672–96. 513 doi:10.1039/c3em00615h 514 6. Chen, Y., Hu, C., Qu, J., Yang, M., 2008. Photodegradation of tetracycline and 515 formation of reactive oxygen species in aqueous tetracycline solution under simulated 516 sunlight irradiation. J. Photochem. Photobiol. A Chem. 197, 81–87. 517 doi:10.1016/j.jphotochem.2007.12.007 518 7. Clesceri, L.S., Eaton, A.D., Greenberg, A.E., American Public Health Association, 519 American Water Works Association, Water Environment Federation, 1998. Standard 520 24 methods for the examination of water and wastewater. American Public Health 521 Association, Washington D.C. 522 8. Daghrir, R., Drogui, P., 2013. Tetracycline antibiotics in the environment: A 523 review. Environ. Chem. Lett. 11, 209–227. doi:10.1007/s10311-013-0404-8 524 9. de Godos, I., Blanco, S., García-Encina, P.A., Becares, E., Muñoz, R., 2009. Long-525 term operation of high rate algal ponds for the bioremediation of piggery wastewaters at 526 high loading rates. Bioresour. Technol. 100, 4332–4339. 527 doi:10.1016/j.biortech.2009.04.016 528 10. de Godos, I., Muñoz, R., Guieysse, B., 2012. Tetracycline removal during 529 wastewater treatment in high-rate algal ponds. J. Hazard. Mater. 229–230, 446–449. 530 doi:10.1016/j.jhazmat.2012.05.106 531 11. Ding, C., He, J., 2010. Effect of antibiotics in the environment on microbial 532 populations. Appl. Microbiol. Biotechnol. 87, 925–941. doi:10.1007/s00253-010-2649-5 533 12. Dzomba, P., Kugara, J., Mukunyaidze, V. V., Zaranyika, M.F., 2015. 534 Biodegradation of tetracycline antibacterial using green algal species collected from 535 municipal and hospital effluents. Der Chem. Sin. 6, 27–33. 536 13. Ferrero, E.M., de Godos, I., Rodríguez, E.M., García-Encina, P., Muñoz, R., 537 Bécares, E., 2012. Molecular characterization of bacterial communities in algal-bacterial 538 photobioreactors treating piggery wastewaters. Ecol. Eng. 40, 121–130. 539 doi:10.1016/j.ecoleng.2011.10.001 540 14. Gelband, H., Miller-Petrie, M., Pant, S., Gandra, S., Levinson, J., Barter, D., White, 541 A., Laximinarayan, R., 2015. The state of the world’s antibiotics. Washington D.C. 542 15. González-Zorn, B., Escudero, J.A., 2012. Ecology of antimicrobial resistance: 543 31 666 Figure 1. Tetracycline concentration and PAR in outdoor batch experiments conducted 667 with biomass sourced from the pilot HRAP during 4 d HRT operation: MQ water control ( 668 Δ ), dead biomass ( × ), active biomass ( □ ). The dotted horizontal line shows the 669 theoretical initial TET concentration. Surface solar irradiance measured during the 670 experiment is shown on the secondary axis (continuous grey line). 671 672 32 Table 1 673 Environmental parameters and productivity recorded during HRAP operation.a 674 Units Stage I Stage II Stage III Stage IV HRAP conditions Start-up (no TET) Continuous TET Continuous TET Continuous or Pulsed TET Pseudo-steady- states b 26th May - 16th June (21 days) 17th June - 21st July (34 days) 29th July - 6th Aug (8 days) 7th Aug - 3rd Sep (27 days) HRT days 7 7 4 4 Average Evaporation L m-2 d-1 2.9 ± 4.6 (21) 7.7 ± 2.2 (32) 10.4 ± 7.8 (10) 6.7 ± 2.3 (27) Average clearsky GHI c W h m-2 8469 8583 8160 7236 Lowd Temperature °C 15.0 ± 2.2 (17) 16.5 ± 0.7 (33) 15.6 ± 1.2 (8) 15.3 ± 0.7 (28) Highd Temperature °C 25.9 ± 3.3 (17) 32.8 ± 1.0 (33) 32.4 ± 1.1 (8) 29.8 ± 1.6 (28) TSS g L-1 1.1 ± 0.3 (6) 1.1 ± 0.1 (10) 1.3 ± 0.6 (3) 1.2 ± 0.1 (8) Lowd pH [ ] 5.5 ± 0.3 (17) 5.6 ± 0.1 (32) 5.9 ± 0.3 (8) 6.2 ± 0.1 (25) Highd pH [ ] 6.5 ± 0.2 (17) 6.9 ± 0.2 (32) 7.5 ± 0.5 (8) 7.3 ± 0.2 (25) Lowd O 2 mg L-1 2.2 ± 1.5 (14) 0.6 ± 0.1 (33) 0.3 ± 0.1 (8) 0.2 ± 0.1 (28) Highd O 2 mg L-1 12.6 ± 0.8 (14) 9.8 ± 0.9 (33) 10.0 ± 2.8 (8) 8.0 ± 0.8 (28) Productivity g m-2 d-1 7.4 ± 5.3 (6) 4.5 ± 2.0 (10) 15.0 ± 1.7 (3) 15.9 ± 4.6 (8) a Data is shown as the mean value ± 95% CI (n). b The days listed in brackets show the 675 duration of the pseudo-steady-state period only – the total time under each set of operating 676 conditions is listed in Section 2.3.1. c Global solar irradiance to a horizontal plane, CAMS 677 radiation service www.soda-pro.com; accessed May 2016. d ‘Low’ and ‘High’ parameters 678 refer to the 5th and 95th percentiles of 24-hour datalogged values. Temperatures given are 679 from the data-logged water temperatures in the HRAP. These percentiles are reported rather 680 than max/min in order to remove potential outliers. 681 33 682 Figure 2. Time course of tetracycline concentrations during the incubation of algal-683 bacterial biomass under darkness and under controlled pH conditions at pH 6 ( ● ), pH 8.5 684 ( ○ ) and pH 10.5 ( × ) or under uncontrolled pH (pH 6.5-6.8) ( □ ) and in MQ water ( Δ ). 685 The horizontal dotted line shows the theoretical initial TET concentration. 686 687 34 Table 2 688 HRAP performance during pseudo-steady state conditions in each operational stage. Data is shown as the mean value ± 95% CI 689 (n). 690 Stage I II III IV Characteristic Influent [mg L -1 ] Effluent [mg L -1 ] RE (%) Influent [mg L -1 ] Effluent [mg L -1 ] RE (%) Influent [mg L -1 ] Effluent [mg L -1 ] RE (%) Influent [mg L -1 ] Effluent [mg L -1 ] RE (%) COD 787 ± 392 (6) 160 ± 26 (6) 75 ± 26 (5) 621 ± 63 (8) 183 ± 18 (9) 84 ± 2 (9) 669 ± 258 (3) 479 ± 241 (3) 78 ± 10 (3) 690 ± 104 (8) 407 ± 31 (8) 79 ± 5 (8) N-NH 4 + 56 ± 16 (6) 5 ± 2 (6) 95 ± 2 (5) 66 ± 13 (10) 14 ± 4.2 (10) 89 ± 2 (10) 72 ± 1 (3) 14 ± 5 (3) 85 ± 4 (3) 59 ± 15 (8) 12 ± 3 (8) 84 ± 3 (8) N-NO 2 - not detected 42 ± 7 (6) n.a. not detected 39 ± 12 (10) n.a. not detected 24 ± 10 (3) n.a. not detected 6 ± 6 (7) n.a. N-NO 3 - not detected 3 ± 4 (6) n.a. not detected 30 ± 18 (10) n.a. not detected 16 ± 4 (3) n.a. not detected 34 ± 14 (8) n.a. P-PO 4 -3 10 ± 10 (6) 7.5 ± 9 (5) 51 ± 8 (4) 10 ± 7 (10) 8.9 ± 8 (7) 49 ± 6 (7) 10 ± 25 (3) 6 ± 53 (2) 59 ± 7 (2) 8 ± 8 (7) 7 ± 7 (7) 31 ± 11 (7) TN 117 ± 10 (5) 58 ± 6 (6) 68 ± 3 (5) 102 ± 9 (9) 91 ± 16 (9) 47 ± 15 (9) 70 ± 20 (3) 54 ± 16 (3) 39 ± 24 (3) 93 ± 11 (8) 59 ± 11 (8) 46 ± 20 (8) TOC 176 ± 44 (6) 32 ± 3 (6) 81 ± 19 (6) 165 ± 11 (9) 42 ± 5 (9) 88 ± 4 (9) 147 ± 113 (3) 44 ± 5 (3) 75 ± 20 (3) 171 ± 19 (8) 46 ± 11 (8) 77 ± 5 (8) IC 87 ± 19 (6) 12 ± 7 (6) 90 ± 5 (6) 87 ± 17 (9) 6 ± 1 (9) 95 ± 1 (9) 82 ± 7 (3) 17 ± 8 (3) 84 ± 8 (3) 88 ± 9 (8) 21 ± 8 (8) 81 ± 7 (8) TSSa 119 ± 27 (6) 16 ± 4 (6) 89 ± 5 (6) 130 ± 16 (10) 22 ± 6 (10) 90 ± 3 (10) 113 ± 47 (3) 51 ± 22 (3) 63 ± 33 (3) 122 ± 42 (8) 57 ± 16 (8) 64 ± 16 (7) a Removal efficiency for TSS was calculated based on influent and clarified effluent concentrations and their respective flow-691 rates to account for evaporation. It thus includes but is not limited to the settling efficiency of the clarifier. 692 35 693 Figure 3. Time course of tetracycline concentrations in the 180L HRAP in the morning 694 (▲) and evening ( Δ ) during continuous supplementation of tetracycline to the wastewater 695 influent at 100 µg TET L-1. The quantification limit is represented by a dotted line. 696 697 36 698 Figure 4. Time course of the PAR (continuous line, half-hour averages) and TET 699 concentration (Δ) during two consecutive TET pulses supplied to the HRAP (27th Aug 700 2015). Vertical arrows represent TET supplementation to the HRAP cultivation broth. 701 702 37 Table 3 703 Summary of pseudo-first order TET kinetic constants (k1) describing TET removal under 704 solar irradiation (10 am - 4 pm) during the pulse tests 705 Day 1 Day 2 Day 1 Day 2 k 1 ± st.error [d-1] (R2, n) k 1 ± st.error [d-1] (R2, n) Average PAR (peak PAR) [µmol m -2 s -1 ] Average PAR (peak PAR) [µmol m -2 s -1 ] 7-Aug 5.6 ± 1.9 (0.70, 6) 1.8 ± 0.3 (0.93, 3) 1329 (1839) 1114 (1851) 13-Aug 9.9 ± 1.8 (0.82, 9) 6.2 ± 0.2 (0.99, 3) 946 (2508) 754 (1931) 18-Aug 7.4 ± 1.8 (0.72, 8) no evening pulse 1285 (1655) n.a. 20-Aug 3.2 ± 0.4 (0.90, 9) 1.4 ± 0.3 (0.79, 4) 1330 1614) 1229 (1786) 27-Aug 2.4 ± 0.4 (0.83, 8) 0.9 ± 0.4 (0.56, 5) 1288 (1766) 1184 (1593) 31-Aug no morning pulse 0.3 ± 0.1 (0.78, 6) n.a. 1026 (1745) 706