scieee AI-readable full text Open interactive document viewer

Transversally and longitudinally stiffened steel plate girders subjected to patch loading

Chacón Flores, Rolando Antonio,Mirambell Arrizabalaga, Enrique,Real Saladrigas, Esther

Abstract

This article presents some observations related to the phenomenon that occurs when transversally and longitudinally stiffened steel plate girders are subjected to patch loading. The failure mechanism differs considerably for the particular structural case of girders with largely spaced transverse stiffeners, which have been studied thoroughly in last decades. Steel plate girders with closely spaced stiffeners are occasionally found in bridge design and for such cases, the current EN1993-1-5 rules underestimate the strength of the webs to transverse forces. Research work on girders with closely spaced transverse stiffeners is available but for such cases, the web plates are longitudinally unstiffened. Some comparisons between the results obtained and those provided by EN1993-1-5 are discussed. Preliminary results suggest that the resistance of densely stiffened steel girders (both transversally and longitudinally) must be studied and subsequently revised accordingly. In addition, it is pointed out that a certain degree of imperfection sensitivity is inferred from the results. Further studies on this topic are necessary.

Full text

Transversally and longitudinally stiffened steel plate girders subjected to patch loading Rolando Chacón, Enrique Mirambell, Esther Real Department of Civil and Environmental Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain Revision submitted to and accepted in THIN WALLED STRUCTURES 2019 Abstract This article presents some observations related to the phenomenon that occurs when transversally and longitudinally stiffened steel plate girders are subjected to patch loading. The failure mechanism differs considerably for the particular structural case of girders with largely spaced transverse stiffeners, which have been studied thoroughly in last decades. Steel plate girders with closely spaced stiffeners are occasionally found in bridge design and for such cases, the current EN1993-1-5 rules underestimate the strength of the webs to transverse forces. Research work on girders with closely spaced transverse stiffeners is available but for such cases, the web plates are longitudinally unstiffened. Some comparisons between the results obtained and those provided by EN1993-1-5 are discussed. Preliminary results suggest that the resistance of densely stiffened steel girders (both transversally and longitudinally) must be studied and subsequently revised accordingly. In addition, it is pointed out that a certain degree of imperfection sensitivity is inferred from the results. Further studies on this topic are necessary. Keywords: Patch loading; EN1993-1-5; Stiffening, longitudinal stiffening, plate buckling 1. Introduction Steel plate girders have been studied profusely in last decades. The usage of such structures in the civil engineering world is vast: countless examples of steel and composite bridges as well as a great number of buildings worldwide are nowadays totally or partially assembled with steel girders. Steel plate girders are designed with either symmetric, non-symmetric I-sections or with a different configurations of box girders. In bridges, I-shaped steel girders are routinely assembled with slender plates for the webs (relatively high values of hw/tw) and with stocky flanges (low values of bf/tf). This combination leads to a high flexural capacity for a relatively low weight. There are, however, issues concerning the stability of the plates assembling the girders. Occasionally, these elements must be stiffened both transversally and longitudinally by welding additional plates that enhance the overall as well as the local behaviour of these elements. From the design perspective, girders assembled with stocky web plates may lead to less stiffening (reducing the labour cost associated with welding but increasing the total weight and the cost associated with the material). Conversely, slender web plates may lead to lighter structures. For an adequate design, these plates often need to be stiffened for the sake of accomplishing all ultimate and serviceability limit states. Constructional guides covering the vast majority of topics dealing with stability and plate girders have been presented by Dowling et al. [1], Galambos [2], Dubas and Gehri [3] and Beg et al. [4]. In bridges assembled with the incremental launching method, patch loading has been identified as one major verification to be considered at design stages. Launching minimizes the use of heavy equipment but implies that all cross-sections of the plate girder pass over temporary supports or piers. Thus, concentrated forces act in both transversally stiffened and unstiffened sections. Occasionally, the thickness of the web (tw) is governed by a temporary concentrated load during the launching operation. An alternative to increasing the web thickness is to stiffen the web plate with equally spaced vertical stiffeners or a combination of vertical and longitudinal elements. Although longitudinal elements are initially conceived for bending and shear capacity, they provide an enhancement to the overall resistance of the plates towards several buckling phenomena. Extensive experimental, numerical and theoretical investigations related to patch loading in both unstiffened and longitudinally stiffened panels have been published. Summary works related to this topic have been presented by Lagerqvist and Johansson [5-6], Chacón et al. [7] and Graciano [8]. From these summaries, a fourfold conclusion (illustrated in Fig. 1) can be extracted:  In unstiffened panels or panels with largely spaced transverse stiffeners, the failure mode of steel plate girders subjected to patch loading is related to web folding under the concentrated load. The ultimate load capacity primarily depends on the web strength as well as on the flange stiffness. The mechanical behaviour of longitudinally unstiffened panels with largely spaced transverse stiffeners is well known. Most predictions found in structural codes are reliable and based upon simple yet accurate formulations derived from mechanical models.  In girders with closely spaced transverse stiffeners, the failure mode is associated with an intertwined mechanism of web folding and flange yielding. The ultimate load capacity primarily depends on the web strength and the flange strength. For the particular case of closely spaced transverse stiffeners, research has been active rather recently and guidelines do not provide an explicit theoretical treatment to those cases. The definition of the distance between transverse stiffeners as large or close is particularly crucial for the definition of the patch loading resistance. Largely spaced transverse stiffeners do not contribute to the resistance to patch loading whereas closely spaced elements allow a considerable redistribution of stresses within the loaded panels at high load levels. Previous works presented by the authors [9-11] show that for girders with aspect ratios a/hw=1,0 (a relatively frequent proportion in bridge design), their resistance to patch loading is considerably enhanced by the presence of such elements.  In longitudinally stiffened panels, web folding under the concentrated load is observed. The ultimate load capacity of longitudinally stiffened elements also depends on the position and the rigidity of the longitudinal stiffener and it is generally higher than the ultimate load capacity of an equivalent member with no longitudinal stiffening. Web folding may be observed in the directly loaded panel or in its vertically adjacent subpanel. Sequential research performed by Graciano et al. [12-15] and Kövesdi et al. [16-17] depicts both critical buckling and ultimate resistance of such elements when subjected to patch loading.  Research related to the particular case of members with longitudinal stiffening and closely spaced transverse elements is scant. Densely stiffened plates, which may provide a considerably high resistance to patch loading, have not yet been studied systematically. In recent years, research has been focused on other aspects of patch loading such as the behaviour of hybrid girders [18-19], eccentric patch loading [20-21] and practical applications for bridge construction [22-23]. In this paper, the previous study is generalized to the case of girders with considerable dense stiffening. Steel plate girders considering both longitudinal stiffeners as well as transverse elements designed with aspect ratios a/hw=1,0 are studied. A set of variations of other geometrical proportions such as web slenderness hw/tw, the longitudinal stiffener position and rigidity and the flange yield stress fyf are studied by means of a numerical parametric study. The study was performed using a commercial FE-package [24] following the recommendations concerning the designer-assumed initial conditions on plate buckling problems provided in [25- 26]. A phenomenological insight of the mechanical behaviour shows the potential stress redistribution and the potential contribution of the longitudinal stiffener. 2. EN1993-1-5 The design load of plate girders subjected to concentrated loads (FRd) is included in the present version of EN1993-1-5 [27] in the same form as in other instability-related problems, i.e., the χλ approach as shown in equations (1) to (4). In this approach, the plastic strength Fy is partially reduced by a χF coefficient which takes instability into account. The effectively loaded length is defined as ly. Note that the magnitude of ly is limited to the distance between transverse stiffeners “a”. If the calculated value “ly” is greater than the geometrical value “a”, the ultimate load carrying capacity given in EN1993-1-5 is proportionally reduced to this transverse spacing. On the other hand, regardless of the potential effect the stiffening may have in the calculation, ly is independent of the presence/absence of longitudinal stiffeners. The benefits that the stiffening provides are implicitly included within the formulation via the buckling coefficient kF (Eq. 5), in which distance “a”, the position b1 and the relative flexural-torsional rigidity γs are included. 1 Rk Rd M F F   (1) ·· · Rk F y F yw y w F yw w F Ffltfat      (2)  2 12 · 2· · 1 2· · 1 0, 02· · yf f w ys f s f yw w f fb h lS t mm S t a ft t                 (3) w 3 w fcr cr y F F Fh t ·E·k·9,0F F F 5.0    (4) 2 , 2 1 , 62· 6 2· 5,44 0,21 · w F unstiffened w F longitudinally stiffened s h ka hb kaa            (5) A hypothetical analysis of such limitation is illustrated in Fig. 2. Assuming that all other variables are held constantly and varying systematically with the distance "a", one may find the following trend: the predicted strength reduces with the spacing between vertical stiffeners "a". A singular point occurs as expected when the geometrical distance "a" equals the calculated effectively loaded length ly. The calculated values of FRd for a given girder are normalized to the obtained value when the girder presents stiffeners separated a long distance (a  ∞). This seems to be counterintuitive to the stiffening philosophy, which suggest that more stiffening should lead to higher capacity of the loaded plates. Nevertheless, the future generation of EN1993-1-5 will include an amended version of this formulation. The effectively loaded length ly has been updated (AM-1-5-11-06) as reads in Eq. 6. Subsequently, the reduction factor was accordingly modified and standardized to other instability-related problems (Eq. 7 to 9). Additional details concerning this amendment as well as its statistical evaluation are provided in [7].  1 2· · 1 2· · 1 f ys f s f w b lS t m S t a t          (6) 0,1 0,1 F 2 FF F   (7) being  F0FF 0FF ·1 2 1 (8) cr ywwy FF f·t·l  (9) 3. Proposed mechanism for girders with closely spaced transverse stiffeners subjected to patch loading Experimentally and numerically, it has been found [9-11] that a typical response curve of girders with closely spaced stiffeners subjected to patch loading follows the qualitative shape illustrated in Fig. 3. Linear initial stages are followed by a bifurcation point in which folding of the web occurs. The system redistributes stresses and the formed web yield lines during folding are anchored in the transverse stiffeners. This anchorage promotes the development of tensile stresses in the web that generate four hinges in the loaded flange. F1 has been identified as the load at which web folding occurs and ΔFF as the additional load that may be carried by the flange while dissipating energy in the plastic collapse. Full collapse of the system occurs at F2. A theoretical solution to the problem of web instability in plate girders with closely spaced vertical stiffeners under patch loading can be found in a predictive model based on two terms (Eq. 10) proposed in [9-10] and improved for practical applications in [11]. The first term contains the web contribution given in the EN1993-1-5 specification for ly=a (web folding of a panel whose width equals “a”). The second term is the corresponding contribution of the flange and it is designated as ΔFF.  * ,() , ·· y R k proposed Rk Rk ly a F F yw w F yl a FFFFFFfatF       (10) For the derivation of ΔFF, a theoretical limit analysis over a defined yield mechanism is used. This mechanism involves the formation of four plastic hinges in the loaded flange of the steel plate girder. It is assumed that the web folds at a load of magnitude F1. Thus, further load increments are resisted by the loaded flange which acts as a flat-beam with cross-section bf· tf subjected to stresses due to bending. If the transverse stiffeners are rigid, the flat beam can be approximated as fully restrained element at both ends and the total length of this member equals to the distance between transverse stiffeners “a”. The flexural resistance of the flange is calculated with Eq. (11) and only the flange cross-section (bf·tf) is considered to be effective in contributing to the strength. However, at load F1, when the frame mechanism is expected to begin, direct stresses are present in the flanges due to global bending. As a result, only a fraction of the nominal yield stress of the flange (fyf) defined as fyf *, can be used in the calculation of the hinge resistance. The magnitude of the flange reserve fyf * is the available strength on those elements when the applied patch load is equal to F1. At this point, the web buckles and the flanges are stressed to some extent due to global bending. The magnitudes of χfi and χfo are defined in Eq. (12) and represent the ratio of actual longitudinal stress in the flange (σfj) when compared to the nominal flange yield stress fyf. ΔFF is subsequently defined in Eq. 13 as the capacity provided by a partially stressed flange. The magnitude of ΔFF accounts for the flange contribution and is obtained using the principle of virtual work in which this partial stress level is included via the ratios χfi and χfo. *2 ·· 4 1 yfffyf ftbM  (11)   ** ,, 1· 1· 1.00.005 jw yf o fo yf yf i fi yf fj yf w h ffff ft              (12)    fifo s yfff fSa ftb F     2· ·· 2 (13) 1.25 0.25· yf yw f kf          (14) It is worth noticing that the proposed ΔFF capacity is implicitly dependent on the web slenderness. Slender girders provide a considerably higher hinge-based capacity when compared to stocky elements. This capacity is also proportionally defined by the available strength fyf*. For slender girders, F1 is low, resulting in a high flange strength reserve. For stocky girders, F1 is high, resulting in a low flange strength reserve. Additionally, for the sake of calibration, an empirically obtained coefficient including the web slenderness is defined in Eq. 12. Finally, the correction coefficient k (Eq. 14) has been proposed to account for the design of hybrid plate girders [28] since it has been also observed that an arbitrarily high value of fyf does not provide an indefinitely high increment of the patch loading capacity. 4. Girders with longitudinal stiffeners If the panel is longitudinally stiffened, the question is to know the influence of the position and/or the flexural-torsional rigidity of the longitudinal stiffener in the failure mechanism of the panel. The influence of the longitudinal stiffener on the resistance of plate girders subjected to patch loading has been generally approached from two perspectives:  The panel is treated as unstiffened and subsequently, a “fs” factor is defined. This factor increases the resistance of the unstiffened panel in a percentage, which is a function of the longitudinal stiffener itself and its position within the panel.  The panel is treated as stiffened and as such, its geometrical conditions can be changed in the definition of Fcr. This approach also leads to a certain increment of FRk as a function of the stiffener and its position. Currently, EN1993-1-5 is based upon this approach. Eq. 5 defines a buckling coefficient accounting for the position b1 and its corresponding flexural-torsional rigidity. Optimal values of longitudinal stiffeners rigidity have been proposed in the literature with satisfactory results [8]. Recent research [16] performed on longitudinally stiffened girders (some of them with closed-sections) includes modified versions of kF with satisfactory results also. One aspect that has been a matter of debate is the distance of the longitudinal stiffener to the loaded flange (b1). While initially conceived for bending purposes, this proportion defines failure on the loaded panel. For some cases, failure is concentrated in the panel below the longitudinal stiffener (low values of b1). For other cases, failure is concentrated in the panel above the longitudinal stiffener (high values of b1). For other cases (weak longitudinal stiffeners, or particular positions), the observed failure mode is rather intertwined between panels. 5. Numerical model The multi-purpose code Abaqus-Simulia [24] has been systematically used as a simulation tool in this research. The code has been widely contrasted and bench-marked in several platebuckling related phenomena. The characteristics of the used numerical model read: • Geometrically, the girders are idealized with S4 shell elements. • Materially, the steel is idealized as elastic-plastic with a von Mises yield criterion. In the case of material idealization including strain hardening, an isotropic hardening model is used. Three different types of steel were modelled (S355, S460 and S690). In all cases, the material has nee idealized as elastic-perfectly plastic with no strain hardening. • The iterative procedure for solving the assembled equation is the Newton-Raphson method. The chosen incremental procedure is based upon the arc-length method. • The stability analysis are performed following an eigenvalue extraction using a subspace procedure. The reproduction of the patch loading phenomena is based upon additional assumptions such as mesh design, geometrical and structural imperfections of the girders. These assumptions are generally “designer-assumed”. Consequently, concerns about the reliability of such assumptions arise, particularly when large systematic parametric studies are developed. The idealization of the girders within this work has been based upon the recommendations provided by EN1993-1- 5-Annex C. These rules provide guidance for using FE-analyses in the calculation of plated structures. The modelling may be either based upon a refined analysis by including geometrical imperfections (Eigenmode-based, for instance) and structural imperfections (residual stresses). Alternatively, it allows the usage of shapes based upon equivalent geometric imperfections. In a series of research papers published by the authors for unstiffened girders, it is suggested that patch loading analysis can be based upon critical Eigenmodes of the structure conveniently scaled a maximum amplitude “w” [25]. EN1993-1-5-Annex C rules recommend a value for w at least of 80% of the maximum allowed fabrication tolerances (80%·FT). In addition, it is stated in EN1993-1-5-Annex C that the chosen imperfection shape should lead to the lowest resistance for each case. In the particular case of patch loading, the initial out-of-flatness of the web in the directly loaded panel should be the most significant initial imperfection. The refined analysis requires the numerical modelling of structural imperfections by means of a typical residual stress pattern [26]. Fig. 4 shows a typical shell-based idealization, the mesh (structured with S4R quadrilateral elements of approximate size 20mm) and the geometrical shape (Eigenmode-based) defined as initial imperfection. The defined geometry is a three-paneled girder that is simply supported along stiffened sections of the outer panels and loaded on the middle one. Fig. 5 shows results provided in [25] in which experimental and numerical values are compared. For the case of longitudinally stiffened webs, similar results have been recently presented by other research groups [17]. 6. Parametric study The numerical model has been used systematically as a simulation tool in order to study steel plate girders subjected to patch loading. The main feature and novelty of this study is the presence of longitudinal stiffeners in girders with closely spaced transverse elements. Conclusions provided by prior studies suggest the following characteristics:  The geometrical proportions that lead to the singular situation in which a/ly<1,0 are found in girders whose web height ranges from 500 mm to 2000 mm. Since longitudinal stiffener are used in this study, the numerical study is developed in girders with hw=a=2000mm. The use of these longitudinal elements is justified in girders with considerable web height.  Other proportions are chosen from according realistic dimensions of steel girders. The web slenderness is varied systematically for covering a broad range.  The flange yield strength fyf plays a primarily role in the development of the post-F1 mechanism. Three values of fyf are included in this study.  All elements are designed with rigid flat longitudinal stiffeners whose dimensions are bstl ·tstl (110mm·30mm) and are held constant.  The position of the longitudinal stiffener ranges from b1/hw=0,2 to b1/hw=0,3 since these values represent the optimal limits for an effective design to bending. The study includes variations of web thickness tw, flange yield stress fyf and the position of the longitudinal stiffener b1. It is worth pointing out that the flanges are defined as stocky elements and as such, the resistance to patch loading is not affected by any transverse bending of the flanges. Table 1 displays the set of variations as well as other magnitudes of interest. An extra set of girders following the same characteristics but longitudinally unstiffened is included for comparison purposes. A total amount of 20 Eigenvalue extractions (buckle) and 60 nonlinear analyses have been performed. 7. Results obtained 7.1 Results obtained with EN1993-1-5 Tables 2 to 5 display the results obtained in all specimens when applying the EN1993-1-5 formulation (based upon the amended formulae only, i.e., equations 6 to 9). Table 2 shows the results obtained for unstiffened girders whereas Tables 3, 4 and 5 show the results obtained when varying b1=400 mm; b1=500 mm and b1=600 mm respectively. The numbering of the girders of each girder in all tables ranges from 1 to 15. Corresponding numbers in all tables are fully comparable (with the varying position as the main difference). Closer inspection on the results obtained allow drawing the following observations:  The calculated values of “ly” are greater than "a" in girders with slender web plates. Strictly, these values are corrected as depicted in section 3. In stocky specimens (tw=12 and tw=15), “ly” is smaller and this particular anomaly does not appear.  The corrected value of ly is independent from fyf. According to EN1993-1-5, the resistance to patch loading FRk happens to be independent of this value.  According to EN1993-1-5, for a given girder, all longitudinally stiffened elements provide a greater buckling load Fcr than their unstiffened counterparts do.  According to EN1993-1-5, for a given girder, all longitudinally stiffened elements provide a greater resistance FRk than their unstiffened counterparts do.  For both buckling (Fcr) and ultimate resistance (FRk), the difference between girders with varying position of the longitudinal element is not very high. The maximum value is consistently obtained for girders with b1=500mm. 7.2 Eigenvalue extraction An Eigenvalue extraction was performed in all specimens with varying geometry. These elements correspond to those labeled as [1;4;7;10;13] in tables 2 to 5.This extraction is elastic and thus independent of the yield stress of the plates assembling the girders. Table 6 displays frontal views of the 1st Eigenmode in 20 simulations. Numerical values are also included. The following observations can be pointed out:  Eigenmodes correspond to plate buckling of the loaded panels. These failure modes are associated to the patch loading phenomena and according to the conclusions presented in [25-26], may be used as a sound initial imperfection.  In some cases (b1=600mm), the shape involves both subpanels (above and below the longitudinal stiffener). This happens for the case of very stocky webs. An intertwined shape covering both subpanels is observed.  The elastic critical buckling loads increase with the web thickness as expected and it is greater for longitudinally stiffened elements than for their unstiffened counterparts.  The elastic critical buckling loads increases with b1. 7.3 Nonlinear analyses Nonlinear analysis in all 60 configurations were performed. The obtained results are presented in the form of response curves for some representative cases. Noticeably, the model provides softening branches with considerable levels of deformation. In this study, plastic damage rules or fracture mechanics were not included in the model. Both extremes (tw=6mm and tw=15 mm) are analyzed in a detailed fashion. 7.3.1 Slender girders Figures 6 to 9 show both response curves and graphical visualizations of the simulations (tw=6mm) at key load levels. The influence of the position b1 as well as the influence of the flange yield stress fyf are assessed. According to the theoretical results, all girders would correspond to the case in which a>ly. Plots are extracted for girders with fyf=355N/mm2. Closer inspection on the results obtained for slender girders allow pinpointing:  Longitudinally stiffened girders present a response curve with some similarities when compared to the unstiffened case. The load-displacement curve shows a lost in linearity which is followed by a post-F1 branch suggesting a change in the resistant mechanism. At a certain value F2, the load-bearing capacity is exhausted.  The position b1 changes, however, key aspects of such plots. For instance, the cases of b1=400mm and b1=500mm present a singular drop in the load-displacement curve. The load increases after some increments following a behavior usually observed in imperfection-sensitive structures.  The overall behavior for b1=600 mm is similar to the one observed in unstiffened girders.  The von Mises stresses at F1 show that a considerable concentration of stresses is located on the directly loaded panel. Since the initial imperfection is related to the panel below the longitudinal stiffener (see table 6), one may expect folding in such panel as well.  The value of F1 is independent from fyf (similarly to unstiffened elements) but the value of F2 is considerably dependent of this magnitude.  The von Mises stresses at F2 also show that a considerable concentration of stresses is located on the directly loaded panel. In this plot, the deformed scale illustrates the hogging-and sagging shape of the loaded flange at this load level.  In all slender girders, strains did not exceeded at 100mm displacement. The study was not concerned with potential excessive straining. For the longitudinally stiffened cases (b1=400mm and b1=500mm), the results suggest that the imperfection may play a role worth investigating. Figure 10 shows contours of the out-of-plane displacement for girders at F1. It shows that for all the studied positions b1, both subpanels are deformed perpendicularly. Although one may not be conclusive with the presented results, this figure provides hints about the shape of the webs at F1 when compared to the shape of the webs at F2 displayed in previous figures. 7.3.2 Stocky girders Figures 11 to 14 show both response curves and graphical visualizations of the simulations. The influence of the position b1 as well as the influence of the flange yield stress f yf are assessed. According to the theoretical results, none of these girders would correspond to the case in which a>ly. Thus, the formulation would not need any revision. In these figures, the nomenclature used previously does not make any sense since neither clear point F1 nor post-F1 branches are observed. Plots associated with Fmax as well as hogging and sagging zones at high level of displacement are presented instead. von Mises stresses at F2 Figure 6. Unstiffened plates. Slender girders tw=6mm von Mises stresses at F1=1070,8 kN von Mises stresses at F2 Figure 7. Longitudinally stiffened girders b1=400mm. Slender girders tw=6mm von Mises stresses at F1=929,9 kN von Mises stresses at F2 Figure 8. Longitudinally stiffened girders b1=500mm. Slender girders tw=6mm von Mises stresses at F1=862,8 kN von Mises stresses at F2 Figure 9. Longitudinally stiffened girders b1=600mm. Slender girders tw=6mm Figure 10. Out of plane displacement at F1 for girders with varying b1=600mm. von Mises stresses at Fmax=4033,1 kN von Mises stresses at δ=50mm Figure 11. Unstiffened web. Stocky girders tw=15mm von Mises stresses at Fmax=4951,7 kN von Mises stresses at δ=50mm Figure 12. b1=400mm. Stocky girders tw=15mm von Mises stresses at Fmax=4600,1 kN von Mises stresses at δ=50mm Figure 13. b1=500mm. Stocky girders tw=15mm von Mises stresses at Fmax=4224,5 kN von Mises stresses at δ=50mm Figure 14. b1=600mm. Stocky girders tw=15mm Figure 15. b1=400mm. Intermediate hw/ tw 0 500 1000 1500 2000 2500 3000 0 20406080 Load (kN) Displacement (mm) fyf=690N/mm2 fyf=460N/mm2 fyf=355N/mm2 Figure 16. F2,num/FRk vs web slenderness Figure 17. F2,num/FRk vs distance b1 Table 1. Variations of the numerical study. Table 2. EN1993-1-5 results for the set of unstiffened girders Table 3. EN1993-1-5 results for the set of girders with b1=400mm h w (mm) 2000 a (mm) 2000 b f (mm) 600 t f (mm) 60 xx s s (mm) 1000 t s (mm) 40 f yw (N/mm2) 355 f ys (N/mm2) 355 f yl (N/mm2) 355 Total 60 t w (mm) f yf (N/mm2) b 1 (mm) Unstiffened 400 500 600 Magnitudes held constant 355 460 690 15 12 8 10 6 Number t w (mm) f yf (N/mm2) l y,nv (mm) hw/tw a/ly l y,corrected (mm) k F Fcr (kN) F y (kN) λ F φ F χ F F Rk F RD U-1 6 355 2320,0 333,3 1,16 2000,0 8 163,3 4260,0 5,11 4,78 0,11 473,6 430,5 U-2 6 460 2320,0 333,3 1,16 2000,0 8 163,3 4260,0 5,11 4,78 0,11 473,6 430,5 U-3 6 690 2320,0 333,3 1,16 2000,0 8 163,3 4260,0 5,11 4,78 0,11 473,6 430,5 U-4 8 355 2159,2 250,0 1,08 2000,0 8 387,1 5680,0 3,83 3,66 0,15 840,0 763,6 U-5 8 460 2159,2 250,0 1,08 2000,0 8 387,1 5680,0 3,83 3,66 0,15 840,0 763,6 U-6 8 690 2159,2 250,0 1,08 2000,0 8 387,1 5680,0 3,83 3,66 0,15 840,0 763,6 U-7 10 355 2049,5 200,0 1,02 2000,0 8 756,0 7100,0 3,06 2,99 0,18 1309,3 1190,2 U-8 10 460 2049,5 200,0 1,02 2000,0 8 756,0 7100,0 3,06 2,99 0,18 1309,3 1190,2 U-9 10 690 2049,5 200,0 1,02 2000,0 8 756,0 7100,0 3,06 2,99 0,18 1309,3 1190,2 U-10 12 355 1968,5 166,7 0,98 1968,5 8 1306,4 8385,9 2,53 2,53 0,22 1865,5 1695,9 U-11 12 460 1968,5 166,7 0,98 1968,5 8 1306,4 8385,9 2,53 2,53 0,22 1865,5 1695,9 U-12 12 690 1968,5 166,7 0,98 1968,5 8 1306,4 8385,9 2,53 2,53 0,22 1865,5 1695,9 U-13 15 355 1878,9 133,3 0,94 1878,9 8 2551,5 10005,4 1,98 2,05 0,28 2834,9 2577,2 U-14 15 460 1878,9 133,3 0,94 1878,9 8 2551,5 10005,4 1,98 2,05 0,28 2834,9 2577,2 U-15 15 690 1878,9 133,3 0,94 1878,9 8 2551,5 10005,4 1,98 2,05 0,28 2834,9 2577,2 Table 4. EN1993-1-5 results for the set of girders with b1=500mm Table 5. EN1993-1-5 results for the set of girders with b1=600mm Numbe r tw (mm) fyf (N/mm2) ly (mm) hw/tw a/ly l y,corrected (mm) k F Fcr (kN) F y (kN) λ F φ F χ F F Rk F RD S-0.2-1 6 355 2320,0 333,3 1,16 2000,0 13,1 267,8 4260,0 3,99 3,80 0,14 605,3 550,3 S-0.2-2 6 460 2320,0 333,3 1,16 2000,0 13,1 267,8 4260,0 3,99 3,80 0,14 605,3 550,3 S-0.2-3 6 690 2320,0 333,3 1,16 2000,0 13,1 267,8 4260,0 3,99 3,80 0,14 605,3 550,3 S-0.2-4 8 355 2159,2 250,0 1,08 2000,0 13,1 634,8 5680,0 2,99 2,93 0,19 1072,7 975,2 S-0.2-5 8 460 2159,2 250,0 1,08 2000,0 13,1 634,8 5680,0 2,99 2,93 0,19 1072,7 975,2 S-0.2-6 8 690 2159,2 250,0 1,08 2000,0 13,1 634,8 5680,0 2,99 2,93 0,19 1072,7 975,2 S-0.2-7 10 355 2049,5 200,0 1,02 2000,0 13,1 1239,8 7100,0 2,39 2,41 0,24 1670,7 1518,8 S-0.2-8 10 460 2049,5 200,0 1,02 2000,0 13,1 1239,8 7100,0 2,39 2,41 0,24 1670,7 1518,8 S-0.2-9 10 690 2049,5 200,0 1,02 2000,0 13,1 1239,8 7100,0 2,39 2,41 0,24 1670,7 1518,8 S-0.2-10 12 355 1968,5 166,7 0,98 1968,5 12,9 2111,8 8385,9 1,99 2,06 0,28 2361,5 2146,8 S-0.2-11 12 460 1968,5 166,7 0,98 1968,5 12,9 2111,8 8385,9 1,99 2,06 0,28 2361,5 2146,8 S-0.2-12 12 690 1968,5 166,7 0,98 1968,5 12,9 2111,8 8385,9 1,99 2,06 0,28 2361,5 2146,8 S-0.2-13 15 355 1878,9 133,3 0,94 1878,9 11,8 3770,1 10005,4 1,63 1,74 0,34 3429,4 3117,7 S-0.2-14 15 460 1878,9 133,3 0,94 1878,9 11,8 3770,1 10005,4 1,63 1,74 0,34 3429,4 3117,7 S-0.2-15 15 690 1878,9 133,3 0,94 1878,9 11,8 3770,1 10005,4 1,63 1,74 0,34 3429,4 3117,7 Numbe r tw (mm) fyf (N/mm2) ly (mm) hw/tw a/ly l y,corrected (mm) k F Fcr (kN) F y (kN) λ F φ F χ F F Rk F RD S-0.25-1 6 355 2320,0 333,3 1,16 2000,0 13,6 277,1 4260,0 3,92 3,74 0,14 615,6 559,6 S-0.25-2 6 460 2320,0 333,3 1,16 2000,0 13,6 277,1 4260,0 3,92 3,74 0,14 615,6 559,6 S-0.25-3 6 690 2320,0 333,3 1,16 2000,0 13,6 277,1 4260,0 3,92 3,74 0,14 615,6 559,6 S-0.25-4 8 355 2159,2 250,0 1,08 2000,0 13,6 656,8 5680,0 2,94 2,89 0,19 1091,0 991,8 S-0.25-5 8 460 2159,2 250,0 1,08 2000,0 13,6 656,8 5680,0 2,94 2,89 0,19 1091,0 991,8 S-0.25-6 8 690 2159,2 250,0 1,08 2000,0 13,6 656,8 5680,0 2,94 2,89 0,19 1091,0 991,8 S-0.25-7 10 355 2049,5 200,0 1,02 2000,0 13,6 1282,8 7100,0 2,35 2,37 0,24 1698,9 1544,5 S-0.25-8 10 460 2049,5 200,0 1,02 2000,0 13,6 1282,8 7100,0 2,35 2,37 0,24 1698,9 1544,5 S-0.25-9 10 690 2049,5 200,0 1,02 2000,0 13,6 1282,8 7100,0 2,35 2,37 0,24 1698,9 1544,5 S-0.25-10 12 355 1968,5 166,7 0,98 1968,5 13,6 2216,7 8385,9 1,95 2,01 0,29 2418,2 2198,3 S-0.25-11 12 460 1968,5 166,7 0,98 1968,5 13,6 2216,7 8385,9 1,95 2,01 0,29 2418,2 2198,3 S-0.25-12 12 690 1968,5 166,7 0,98 1968,5 13,6 2216,7 8385,9 1,95 2,01 0,29 2418,2 2198,3 S-0.25-13 15 355 1878,9 133,3 0,94 1878,9 13,0 4147,6 10005,4 1,55 1,67 0,36 3592,0 3265,5 S-0.25-14 15 460 1878,9 133,3 0,94 1878,9 13,0 4147,6 10005,4 1,55 1,67 0,36 3592,0 3265,5 S-0.25-15 15 690 1878,9 133,3 0,94 1878,9 13,0 4147,6 10005,4 1,55 1,67 0,36 3592,0 3265,5 Numbe r tw (mm) fyf (N/mm2) ly (mm) hw/tw a/ly l y,corrected (mm) k F Fcr (kN) F y (kN) λ F φ F χ F F Rk F RD S-0.3-1 6 355 2320,0 333,3 1,16 2000,0 13,1 268,0 4260,0 3,99 3,80 0,14 605,5 550,4 S-0.3-2 6 460 2320,0 333,3 1,16 2000,0 13,1 268,0 4260,0 3,99 3,80 0,14 605,5 550,4 S-0.3-3 6 690 2320,0 333,3 1,16 2000,0 13,1 268,0 4260,0 3,99 3,80 0,14 605,5 550,4 S-0.3-4 8 355 2159,2 250,0 1,08 2000,0 13,1 635,1 5680,0 2,99 2,93 0,19 1073,0 975,5 S-0.3-5 8 460 2159,2 250,0 1,08 2000,0 13,1 635,1 5680,0 2,99 2,93 0,19 1073,0 975,5 S-0.3-6 8 690 2159,2 250,0 1,08 2000,0 13,1 635,1 5680,0 2,99 2,93 0,19 1073,0 975,5 S-0.3-7 10 355 2049,5 200,0 1,02 2000,0 13,1 1240,5 7100,0 2,39 2,41 0,24 1671,2 1519,2 S-0.3-8 10 460 2049,5 200,0 1,02 2000,0 13,1 1240,5 7100,0 2,39 2,41 0,24 1671,2 1519,2 S-0.3-9 10 690 2049,5 200,0 1,02 2000,0 13,1 1240,5 7100,0 2,39 2,41 0,24 1671,2 1519,2 S-0.3-10 12 355 1968,5 166,7 0,98 1968,5 13,1 2143,6 8385,9 1,98 2,04 0,28 2378,8 2162,6 S-0.3-11 12 460 1968,5 166,7 0,98 1968,5 13,1 2143,6 8385,9 1,98 2,04 0,28 2378,8 2162,6 S-0.3-12 12 690 1968,5 166,7 0,98 1968,5 13,1 2143,6 8385,9 1,98 2,04 0,28 2378,8 2162,6 S-0.3-13 15 355 1878,9 133,3 0,94 1878,9 13,1 4186,7 10005,4 1,55 1,67 0,36 3608,4 3280,4 S-0.3-14 15 460 1878,9 133,3 0,94 1878,9 13,1 4186,7 10005,4 1,55 1,67 0,36 3608,4 3280,4 S-0.3-15 15 690 1878,9 133,3 0,94 1878,9 13,1 4186,7 10005,4 1,55 1,67 0,36 3608,4 3280,4 Table 6. Elastic buckling modes and shapes for the 1st Eigenvalue tw(mm) Unstiffened b1=400 mm b1=500 mm b1=600 mm 6 Fc r =237,2 kN Fc r =411,6 kN Fc r =477,6 kN Fc r =552,8 kN 8 Fc r =550,6 kN Fc r =937,6 kN Fc r =1077,0 kN Fc r =1193,8 kN 10 Fc r =1056,4 kN Fc r =1753,4 kN Fc r =1979,2 kN Fc r =2097,4 kN 12 Fc r =1795,6 kN Fc r =2910,8 kN Fc r =3210,2 kN Fc r =3317,4 kN 15 Fc r =3421,2 kN Fc r =5410,0 kN Fc r =5842,6 kN Fc r =5893,8 kN