scieee AI-readable full text Open interactive document viewer

Control of electric drives with high switching frequency operation capabilities: envisionning future prospects

Repecho del Corral, Víctor,Biel Solé, Domingo,Arias Pujol, Antoni

Abstract

Industrial drives are currently of great relevance considering the technological challenges associated with climate change mitigation. Current technologies use silicon devices with switching frequencies around 10 kHz. However, new wide bandgap (WBG) devices are expected to replace these technologies and allow operation at switching frequencies of 100 kHz or higher. This may have implications for how control algorithms for electrical drives are implemented. In this perspective paper the authors analyse and discuss the implications of high frequency operation on control, and predict the possible widespread use of hysteretic controllers suitable for operating in such switching regimes.

Full text

CONTROL OF ELECTRIC DRIVES WITH HIGH SWITCHING FREQUENCY OPERATION CAPABILITIES: ENVISIONING FUTURE PROSPECTS Tecnología Electrónica PERSPECTIVAS Edorta Ibarra, Antoni Arias, Victor Repecho, Domingo Biel, Andres Sierra- Gonzalez, Iñigo Kortabarria 3307.99 Convertidores de potencia Publicaciones DYNA SL -- c) Mazarredo nº69 - 2º -- 48009-BILBAO (SPAIN) Tel +34 944 237 566 – www.revistadyna.com - email: [email protected] Pag. 1 / 5 ISSN: 0012-7361 eISSN: 1989-1490 / DYNA Vol.99 n.2 DOI: https://doi.org/10.6036/10974 CONTROL OF ELECTRIC DRIVES WITH HIGH SWITCHING FREQUENCY OPERATION CAPABILITIES: ENVISIONING FUTURE PROSPECTS Edorta Ibarra1, Antoni Arias2, Victor Repecho2, Domingo Biel2, Andrés Sierra-Gonzalez3 e Iñigo Kortabarria1 1 Universidad del País Vasco - UPV/EHU (España) 2 Universidad Politécnica de Cataluña. UPC (España) 3 TECNALIA, Basque Research and Technology Alliance (España) DOI: https://dx.doi.org/10.6036/10974 1. INTRODUCTION Over recent years, electric drives gained relevance both in academy and industry for traction applications [1, 2]. Here, closed loop control is fundamental for high-performance drives to achieve fast, smooth, robust and efficient electrical and motion performance. Thus, topics related with good control practices are of great interest for field engineers working in a variety of electro-mobility solutions (road vehicles, more electric aircrafts, etc.) and industrial fields. Power converters’ switching frequency is an important feature that characterizes electric drives’ performance. Mostly, state-of-the-art electric drive power inverters rely on silicon IGBT or MOSFET semiconductors. Considering efficiency, thermal management and semiconductor technology constraints, silicon-based converters typically operate with switching frequencies from 5 kHz up to 20 kHz. However, more advanced silicon carbide (SiC) and gallium nitride (GaN) wide-bandgap (WBG) devices enable better efficiencies, higher operation temperatures, and faster switching speeds, this last providing lower torque ripple and extending electric machines’ controllable speed range. Many authors believe WBG devices will substitute silicon ones in the short-to-mid term [3, 4]. Authors in [4] showcase SiC-based traction inverters, operating at switching frequencies of 100 kHz, which exhibit good inverter/machine efficiency figures. Thus, operating low and medium power inverters with such high frequencies is already technologically feasible. Considering the potential evolution of WBG technologies, switching frequencies far above 100 kHz could be envisioned in the midfuture for GaN technologies. As semiconductors improve, losses could be kept reasonable while taking advantage of high switching operation. Literature discusses these high frequency implications from a power loss [4] or Common Mode Voltage [5] perspective but, in general, discussions about control are still missing beyond high speed controllability. The authors of this work are actively involved in researching advanced control solutions for electric drives. They believe that the evolution in such enabling semiconductor technologies posses deep implications on how electric drive controllers could be implemented in the future. Similar to how good room temperature control is possible by simply using hysteresis band regulators as the room thermal dynamic is slow, hysteretic motor control could provide performance results comparable to the now state-of-the-art vector controllers when semiconductor switching frequencies are high enough relative to the electric machine dynamics. To understand such deep implications, let’s focus first on how modern drives can be controlled. 2.- PI- AND HYSTERESIS-BASED CONTROL APPROACHES FOR VARIABLE SPEED DRIVES PI-based Field Oriented Control [FOC, Figs. 1 and 2(a)] is the most popular torque regulation technique for electric drives [6]. Here, stator currents are transformed into a fictitious two-dimensional synchronous reference frame by the application of static (C, Clarke) and rotational (P, Park) transformations (T=C.P), see Fig. 2(a). To track the synchronous current references, PI controllers determine the instantaneous stator voltages, which are then synthesized by means of a Pulse Width Modulator [PWM, Fig. 2(a)]. As an alternative to the classical PI-based FOC, the basic hysteresis regulation scheme of Fig. 2(b) can be highlighted [7]. Here, the synchronous reference currents are anti-transformed into a per-phase representation applying T-1. Then, hysteresis comparators directly provide power semiconductors’ gating signals, according to the hysteresis bands and the per-phase current errors. The width of the bands allows to set the current ripple to a given value. Reducing such bands increases switching frequency, and vice versa. The basic hysteresis controller is the simplest to be computed. However, one of its drawbacks is that non-independent variables are simultaneously trying to be regulated, i.e., phase currents are coupled (in a star-connected system, Σij=0). Also, variable switching frequency is produced, which is not desirable from a power loss and thermal management perspective (maximum switching frequency cannot be formally assessed as electric machine aging can vary phase inductances to an undetermined value). CONTROL OF ELECTRIC DRIVES WITH HIGH SWITCHING FREQUENCY OPERATION CAPABILITIES: ENVISIONING FUTURE PROSPECTS Tecnología Electrónica PERSPECTIVAS Edorta Ibarra, Antoni Arias, Victor Repecho, Domingo Biel, Andres Sierra- Gonzalez, Iñigo Kortabarria 3307.99 Convertidores de potencia Publicaciones DYNA SL -- c) Mazarredo nº69 - 2º -- 48009-BILBAO (SPAIN) Tel +34 944 237 566 – www.revistadyna.com - email: [email protected] Pag. 2 / 5 ISSN: 0012-7361 eISSN: 1989-1490 / DYNA Vol.99 n.2 DOI: https://doi.org/10.6036/10974 Fig. 1. General diagram of a speed controlled three-phase PMSM incorporating a two-level three-phase inverter, and a FOC current controller for torque regulation. Fig. 2. Simplified block diagrams of FOC current regulation alternatives: (a) PI-based with PWM (excluding feed-forward terms), (b) basic current hysteresis regulators, and (c) SMC with fixed or variable hysteresis bands. Alternatively, more refined hysteresis-based FOC approaches using sliding mode control (SMC) theory can be found [8], see Fig. 2(c). Here, a decoupling matrix M leads to a set of decoupled sliding surfaces σj that allow controlling all the phase currents through regulating two of them. The average value of the neutral point voltage can be controlled with the remaining degree-of-freedom. SMC provides mathematical tools to assess system’s stability. Also, it is relatively straightforward to dynamically vary the hysteresis bands and set a fixed switching frequency [9], thus solving the drawbacks of variable frequency operation. Both hysteretic approaches provide a very robust operation under plant uncertainties and variations, which could result in a better motor drive performance. Similarly, the ideally infinite bandwidth (limited by the finite switching frequency in real applications) enables to track whichever current reference beyond a sinusoidal one, which is of practical interest in some fault-tolerant control applications [7]. 3.- HIGH SWITCHING FREQUENCY OPERATION IMPLICATIONS IN WAVEFORM QUALITY To illustrate the performance of these discontinuous controllers vs classical FOC, simulations of a three-phase PMSM drive are presented hereafter. The electric machine is fed by a two-level three-phase Voltage Source Inverter (VSI). Most relevant parameters of the drive are collected in Table 1. They represent a typical low power PMSM used in industrial applications. Table 1. Most relevant plant and control parameters of the simulated PMSM electric drive. CONTROL OF ELECTRIC DRIVES WITH HIGH SWITCHING FREQUENCY OPERATION CAPABILITIES: ENVISIONING FUTURE PROSPECTS Tecnología Electrónica PERSPECTIVAS Edorta Ibarra, Antoni Arias, Victor Repecho, Domingo Biel, Andres Sierra- Gonzalez, Iñigo Kortabarria 3307.99 Convertidores de potencia Publicaciones DYNA SL -- c) Mazarredo nº69 - 2º -- 48009-BILBAO (SPAIN) Tel +34 944 237 566 – www.revistadyna.com - email: [email protected] Pag. 3 / 5 ISSN: 0012-7361 eISSN: 1989-1490 / DYNA Vol.99 n.2 DOI: https://doi.org/10.6036/10974 Figs. 3 to 5 summarize the simulation results for the three studied control approaches operating at 10 kHz (typical to silicon devices), at rated current and 2/3 rated speed (100 Hz electrical). Fig. 3 shows the phase-to-neutral voltage and a phase current obtained when applying the conventional PI-based FOC. As expected, the lowest harmonic content is achieved. The typical harmonic distribution around switching frequency and its multiple bands is obtained with a Total Harmonic Distortion (THD) of 4,5 % for the total measured spectrum (Table 2). Fig. 3. PI-based FOC at 10 kHz switching frequency. Phase-to-neutral voltage (top), current (mid) and current harmonics spectrum, excluding fundamental (bottom). Table 2. Current THD results obtained for the simulated PMSM drive for the studied controllers. The basic hysteresis controller was then set to operate with a switching frequency centered at 10 kHz (Fig. 4). Current ripple is constrained to the defined hysteresis bands. However, the continuous application of zero vectors by the inverter during various timeintervals prevents currents to rebound between the bands during such instants. This is because the three coupled currents are being simultaneously regulated. Moreover, the variable switching frequency generates additional harmonic components, even low-order ones, and a THD of 11,80 % is obtained if considering the full spectrum. Also, a relatively high THD is obtained when only considering the first 40 harmonics, as ruled by the Spanish UNE-EN 61000-3-2 norm (Table 2). Such behaviour makes, in most cases, hysteresis controllers less appealing to control engineers than PI-based FOC. Fig. 5 shows the results obtained when applying SMC with fixed switching frequency. As shown in the spectrum, harmonics concentrate around 10 kHz, indicating that switching frequency is fixed within a narrow band. Boundary rebounds are always homogeneous, in contrast to the basic hysteresis regulators, as here control variables are decoupled. When considering full spectrum, a higher THD figure than the basic hysteresis controller is obtained (Table 2). In contrast, THD is better when only considering the first 40 harmonics, as few low-harmonic components are present. CONTROL OF ELECTRIC DRIVES WITH HIGH SWITCHING FREQUENCY OPERATION CAPABILITIES: ENVISIONING FUTURE PROSPECTS Tecnología Electrónica PERSPECTIVAS Edorta Ibarra, Antoni Arias, Victor Repecho, Domingo Biel, Andres Sierra- Gonzalez, Iñigo Kortabarria 3307.99 Convertidores de potencia Publicaciones DYNA SL -- c) Mazarredo nº69 - 2º -- 48009-BILBAO (SPAIN) Tel +34 944 237 566 – www.revistadyna.com - email: [email protected] Pag. 4 / 5 ISSN: 0012-7361 eISSN: 1989-1490 / DYNA Vol.99 n.2 DOI: https://doi.org/10.6036/10974 Although, at 10 kHz, PI-based FOC exhibits better waveform quality, differences become narrower between control approaches when increasing switching frequencies up to 100 kHz (Table 2). In particular, Fig. 6 illustrates how good is the output current waveform for the most basic hysteresis controller at such high frequency operation conditions. THD figures become even closer as switching frequency further increases, making the waveform differences between the three control approaches negligible. Fig. 4. Basic hysteresis controller, switching frequency centered at 10 kHz (variable frequency). Phase-to-neutral voltage (top), current (mid) and current harmonics spectrum, excluding fundamental (bottom). Fig. 5. SMC FOC controller, fixed switching frequency at 10 kHz. Phase-to-neutral voltage (top), current (mid) and current harmonics spectrum, excluding fundamental (bottom). CONTROL OF ELECTRIC DRIVES WITH HIGH SWITCHING FREQUENCY OPERATION CAPABILITIES: ENVISIONING FUTURE PROSPECTS Tecnología Electrónica PERSPECTIVAS Edorta Ibarra, Antoni Arias, Victor Repecho, Domingo Biel, Andres Sierra- Gonzalez, Iñigo Kortabarria 3307.99 Convertidores de potencia Publicaciones DYNA SL -- c) Mazarredo nº69 - 2º -- 48009-BILBAO (SPAIN) Tel +34 944 237 566 – www.revistadyna.com - email: [email protected] Pag. 5 / 5 ISSN: 0012-7361 eISSN: 1989-1490 / DYNA Vol.99 n.2 DOI: https://doi.org/10.6036/10974 Fig. 6. Basic hysteresis controller, switching frequency centered at 100 kHz (variable frequency). Current (top) and harmonic spectrum, excluding fundamental (bottom). 4.- CONCLUSIONS Hysteretic controllers can achieve waveform results equivalent to modulator based solutions at very high switching frequencies keeping their major benefits: high robustness and ultra-fast dynamic response. In particular, the basic hysteresis controller provides an extremely good current waveform for switching frequencies beyond 100 kHz, attaining great conceptual implementation simplicity. This could make it more widespread in the future, especially among engineers that are not control specialists, as very few adjustments beyond the width of the hysteresis bands are required. Some practical aspects must be considered, however. For digital implementation, fast devices such as FPGAs should be used to accurately determine the crossing instants between error signals and hysteresis bands. Fast A/D converters and high bandwidth current sensors are also desirable, not to forget addressing potential EMC issues. Hybrid implementation could be finally envisioned, digitally generating set-points, converting them into analog domain using D/A converters, and implementing hardware hysteresis regulators. Although it is difficult to assess hysteretic schemes could be favored in the future, authors believe that a wider adoption of them will be a reality in applications where simplicity, robustness and fast dynamic operation are desirable. Here, torque enhancement or fault tolerant techniques for multiphase machines are worth to mention, where fast varying current set-point tracking is mandatory. REFERENCES [1] Sierra-Gonzalez A, Peschetto P, Alvarez-Gonzalez F, et al. “Full-speed range control of a symmetrical six-phase automotive IPMSM drive with a cascaded DC-link configuration”. 2023. Vol. 59, no. 3. p. 3413-3424. DOI: 10.1109/TIA.2023.3256382 [2] Sayed E, Pietrini G, Sa’adeh NM, et al. “Review of electric machines in more-/hybrid-/turbo-electric aircraft”. IEEE Transactions on Transportation Electrification. December 2021. Vol. 7, no. 4. p. 2976-3005. DOI: 10.1109/TTE.2021.3089605 [3] Robles E, Matallana A, Aretxabaleta I, et al. “The role of power device technology in the electric vehicle powertrain”. International Journal of Energy Research. 2022. Vol. 46. p. 22222-22265. DOI: 10.1002/er.8581 [4] Chang L, Alvi M, Lee W, et al. “Efficiency optimization of PWM-induced power losses power losses in traction drive systems with IPM machines using wide bandgapbased inverters”. IEEE Transactions on Industry Applications. September/October 2022. Vol. 58, no. 5. p. 5635-5649. DOI: 10.1109/TIA.2022.3178979. [5] Xu Y, Yuan X, Ye F, et al. “Impact of high switching speed and high switching frequency of wide-bandgap motor drives on electric machines”. 2021. IEEE Access. Vol. 6. p. 82866-82880. DOI: 10,1109/ACCESS.2021.3086680 [6] Wilson D. “Field-oriented control: historical foundations”. EE Times. 2015. https://www.eetimes.com/field-oriented-motor-control-historical-foundations/ (online, consultation date: 24/03/2023) [7] Mohammadpour A, Sadhegi S, Parsa L. “A generalized fault-tolerant control strategy for five-phase PM motor drives considering star, pentagon, and pentacle connections of stator windings”. IEEE Transactions on Industrial Electronics. January 2014. Vol. 61, no. 1. p. 63-75. DOI: 10.1109/TIE.2013.2247011 [8] Utkin V, Guldner J, Shi J, “Sliding mode control in electromechanical systems, 2nd edition”. CRC Press. 2017. [9] Repecho V, Biel D, Arias A. “Fixed switching period discrete-time sliding mode current control of a PMSM”. IEEE Transactions on Industrial Electronics. 2018. Vol. 65, no. 3. p. 2039-2048. DOI: 10.1109/TIE.2017.2745469