1 Computer simulation of ion-exchange membrane electrodialysis for salt concentration and reduction of RO discharged brine for salt production and marine environment conservation Yoshinobu Tanakaa*, Monica Reigb, Sandra Casasb,d, Carlos Aladjemc, Jose Luis Cortinab,d a IEM Research, 1-46-3 Kamiya, Ushiku-shi, Ibaraki 300-1216, Japan b Chemical Engineering Dept. UPC-Barcelona TECH, Av. Diagonal 647, 08028 Barcelona, Spain c SOLVAY Iberica SL. C/Marie Curie 1-3-5, 08760 Martorell, Spain d CETAQUA Carretera d’Esplugues, 75, 08940 Comella de Llobregat, Spain * Corresponding author, Tel.: +81-29-874-5400, E-mail address:
[email protected] ABSTRACT The salt discharged from reverse osmosis (RO) is concentrated by ion-exchange membrane electrodialysis (ED) to produce salt for industrial use while the salt concentration is reduced to seawater level in order to prevent environmental impact on marine ecosystems. The technology was evaluated experimentally and discussed with a computer simulation program of the ED system incorporated with U-shape cells. The algorithm computes mass transport, energy consumption, electric current leakage, concentrate NaCl purity, pressure drop and limiting current density. The sea water RO discharged brine was supplied to the ED pilot plant and it was operated changing current density and temperature taking benefit of seasoning variations. The computed energy consumption ENaCl and NaCl concentration in concentrated solutions C”NaCl are compared to the experimentally observed values. The correlation coefficients are R(r) = 0.863 for ENaCl and R(r) = 0.553 for C”NaCl. Thus the reasonability of the developed algorithms is supported by the experiments. The current leakage is nearly three percent for any electric current. The pump driving force is ca. 1 – 2 percent of energy consumption. The limiting current density is very high (over ten times of current density). In order to decrease salt concentration at the outlets of desalting cells to seawater level, it is necessary to increase desalting ratio to 0.5. This technique however increases ENaCl and decreases C”NaCl. In spite of this operating circumstance, ENaCl and C”NaCl are comparable to the data in the salt manufacturing plant operation to produce edible salt. NaCl produced from the RO discharged brine ED is competitive in the edible salt market.
2 Keywords: Computer simulation; Concentration; Desalination; Electrodialysis; Ion exchange membrane; Reverse osmosis 1. Introduction The 21st century is called “the century of water” because of the water crisis due to the population increase and environmental destruction. The fresh water from surface water (rivers and lakes) and ground water totals only 0.01 % of total water resources on the earth. To secure adequate water resources, effective and cyclic utilization of water are available, but at the same time, desalination of seawater which accounts for 97.54 % of total water resources is realistic. Seawater desalination is carried out extensively at present particularly in the Arabian Gulf, Mediterranean Sea, Red Sea, Southeast Asia, etc. The main desalination processes are multi-stage flash distillation (MSF), multiple-effect distillation (MED) and reverse osmosis (RO). In order to produce clean drinking water, the seawater environment is expected to be clean. However, it is a contradiction that the effluent and emission produced by the desalination plants are affecting the seawater environment. Seawater desalination plants produce drinking water and discharge concentrated brine which has a higher density than seawater. The brine spreads over the sea floor in shallows, so it is usually dissipated by a diffuser system to be mixed with seawater [1]. However, the perfect mixing of a large amount of the discharged brine with surrounding seawater is impossible. In a closed water area such as Arabian Gulf, Mediterranean Sea etc., the discharged brine increases seawater concentration and pollutes seawater because it dissolves several chemical additives, chemical cleaning solutions and pretreatment chemicals [2 – 6]. It impairs marine life and induces negative environmental impacts such as diminishing the biological diversity [7 - 10]. We have to pay attention further to the fact that desalination plants require significant amounts of thermal and electrical energy, which causes greenhouse gas emissions and global warming [11]. Pérez-González et al. [12] gave an overview on the treatments to overcome the environmental problems associated to the direct discharge of RO concentrates. Xu et al. [13] reviewed strategies and technologies for concentrate management, including disposal, treatment, and beneficial use. The process described in this article is the RO-ED hybrid system, which has been also postulated in similar investigations. Thomas [14] reported zero discharge seawater desalination, integrating the production of freshwater, salt, magnesium and bromine. The process used ED to reduce the salinity of the reject stream from RO so that the salt-depleted rejection stream could be recycled to the RO to improve the yield of freshwater. Zhang et al. [15] investigated the feasibility of ED on the RO concentrate to reduce the volume of salty water discharged and to
3 improve the overall water recovery to produce infiltration water for groundwater recharge. In the pilot system, the decarbonation process was used to reduce scaling potential of the feed or the concentrate stream of the ED. Tran et al. [16] investigated the feasibility of a hybrid system consisting of a pellet reactor and ED to treat RO concentrate in which the pellet reactor was used to remove the scaling potential before ED treatment. The objective of the hybrid system was a high recovery for the RO system, and zero liquid discharge for the RO. McGoven et al. [17] discussed RO-ED hybrid system by modeling the energy and equipment costs of ED as a function of product salinity. Specifying the feed salinity along with the product salinity and flow rate, the equations were solved using a non-linear equation solver to compute the final concentrate concentration, total membrane area, energy consumption, specific equipment cost, specific energy cost, and specific water costs. Tanaka et al. [18] discussed operating parameters of an ion-exchange membrane electrodialytic salt manufacturing plant using brine discharged from a RO seawater desalination plant. The energy consumption in the salt manufacturing process using RO discharged brine was 80 % of the consumption in the process using seawater. Casas et al. [19] studied a technology to concentrate NaCl from RO reject in order to be reused in the chlor-alkali industry. A mathematical model was developed based on the Nernst-Planck equations to predict the performance of the ED pilot plant. The model was able to accurately predict the NaCl concentration reached, time required to reach maximum concentration and production overflow as a function of the operation conditions. Reig et al. [20] concentrated NaCl from seawater RO brines for chlor-alkali industry by the ED pilot plant, and discussed the limiting current density, the behavior of miner and trace species dissolving in the brine and energy consumption. Jiang et al. [21] electrodialyzed highly concentrated brine from RO plant to produce coarse salt and freshwater, and investigated the effect of operation parameters such as current density, operation mode, type of membranes and initial brine concentration. This article discusses the technology of salt concentration and reduction of RO discharged brine by ion-exchange membrane (IEM) electrodialysis (ED) for salt production and marine environment conservation. The investigation is carried out at first to develop the computer simulation program describing the performance of the ED system. Next, real RO discharged brine is supplied to the pilot plant and it is operated changing current density and temperature. The computed energy consumption and NaCl concentration in concentrated solutions are compared to the observed values. Computer simulation is one of the useful tools to discuss the performance of electrodialyzers and widely applied to the technology development [22 - 29]. The previous work (Reference [18]) includes the original concept of the computer program, but it is impossible to calculate the performance of electrodialyzers. The other previous works (References [19, 20]) extended experimental observation vigorously, but quantitative analysis is insufficient. The current investigation successfully discusses the experimental results using the
4 computer program updated in the succeeding investigation [30]. The computer simulation program is now accessible through a companion website, and it provides a guideline for designing, manufacturing and operating practical-scale electrodialyzers [31]. 2. Electrodialysis process In Fig. 1, RO discharged brine (Feeding solution, salt concentration C’in) is supplied to desalting cells (inlet linear velocity; u’in), partition cells and electrode cells. The concentrated solution is circulated between concentrating cells (inlet linear velocity; u”in) and circulation tank and an electric current I is passed through electrodes. Salt concentration in concentrating cells and in the circulation tank is increased with time and reaches to a steady state. After C” (salt concentration in concentrating cells) and C’out (salt concentration at the outlets of desalting cells) reach steady values, C” and C’out are measured. Structure of the flow-pass in the cell is classified to an I-shape and a U-shape. Flow-pass structure in the ED pilot plant described in this article is incorporated with U-shape cells (Photo 1). The computer simulation program is applicable to the I-shape cell as illustrated in Fig. 2. Thus it is necessary to create an imaginary I-shape cell equivalent to a U-shape cell. In this investigation, the structure of the imaginary I-shaped cell is assumed to be illustrated by Fig. 2. Fig. 3 shows the structure of a spacer integrated in desalting and concentrating cells. Fig. 4 illustrates the mass transport in an imaginary I- shape cell pair in an electrodialyzer operating in a steady state with a constant electric current I. A salt solution (raw salt solution, concentration: C’in) is supplied to the inlets of desalting cells (De) at average linear velocity of u’in. A concentrated solution (concentration: C”) is supplied to the inlets of concentrating cells (Con) at the inlet average linear velocity of u”in. Ions and solutions transfer from a desalting cell to a concentrating cell across an IEM pair and their flux is defined by JS and JV respectively. 3. Electrodialysis program The performance of the ED unit operating in a steady state can be computed with a single computation in the spreadsheet using a common software (Excel) and ordinary hardware (computer). Fig. 5 shows the ED program chart. It is operated by inputting the source code i.e. optional process specifications and operating conditions of the unit integrated with imaginary I-shaped cells. The program consists of the equations explained below: 3.1 Membrane characteristics Ion flux JS and solution flux JV transported from desalting cells toward concentrating cells
5 are expressed by the following overall mass transport equation [32]. JS(eqcm-2s-1) = λ iμ (C”–C’) = (tK + tA - 1) i/F – μ (C”–C’) = η i/F = C”JV (1) JV (cms-1) = φ i + ρ (C” – C’) (2) in which, i (A/cm2) is current density, tK and tA are transport number of a cation-exchange membrane (CEM) and an anion-exchange membrane (AEM) respectively, η is current efficiency, λ is the overall transport number, μ is the overall solute permeability, φ is the overall electro-osmotic permeability and ρ is the overall volume osmotic permeability. λ , μ , φ are expressed by the following function of ρ . λ (eq A-1s-1) = 9.208×10-6 + 1.914×10-5 ρ = (tK + tA -1)/F (3) μ (cm s-1) = 2.005×10-4 ρ (4) φ (cm3A-1s-1) = 3.768×10-3 ρ 0.2 – 1.019×10-2 ρ (5) ρ is presented by the following function of temperature T (℃) [33]. ρ (cm4eq-1s-1) = 3.421×10-3 + 3.333×10-4T (6) The overall membrane pair characteristics λ , μ , φ and ρ are determined by setting temperature T (℃) using Eqs. (3) – (6). Eqs. (3) – (6) are introduced for seawater ED incorporating the available properties of the following commercially homogeneous IEMs. Aciplex CK-2/CA-3, K-172/A172 (Asahi Chemical Co. Japan) Selemion CVS2/AST, CMR/ASR (Asahi Glass Co., Japan) Neosepta CL25T/AVS4T, CIMS/ACS3 (Tokuyama Co., Japan) 3.2 Salt concentration and solution velocity in the cells In Fig. 4, salt concentration in the desalting cells is assumed to be changed linearly from the inlets to the outlets. The average salt concentration C’ (eq/cm3) is expressed by the following equation: C’ = (C’in + C’out*)/2 (7)
6 C’out* is an unknown parameter at this stage. Superscript * supplied to the unknown parameter denotes the control key. In the concentrating cells, salt concentration is uniform and it is given from Eqs. (1) and (2) as: 2 1 "/ 4 2 SV CJJ A BA ρ ρ (8) A = φ i + μ – ρ C’ B = λ i + μ C’ The average linear velocity u’ and u’’ (cm/s) in the cells are: In the desalting cells; u’ = (u’in + u’out)/2 (9) In the concentrating cells; u” = (u”in + u”out)/2 (10) where u’out and u”out are calculated using the following equations: u’out = u’in - (l/a’)JV (11) u”out = u”in + (l/a”)JV (12) in which, a’ and a” are the flow pass thickness of the desalting cell and concentrating cell, respectively. C’out and C” are calculated using the following equations: C’out u’out = C’in u’in - (l/a’)JS (13) C”u”out = C”u”in + (l/a”)JS (14)
7 3.3 Decision point 1 C’out calculated above is erroneous because the computation starts by substituting tentatively the determined (unknown) C’out* (control key) in Eq. (7). In order to determine accurate C’out, the following trial-and-error calculation is carried out. C’out = C’out* (15) The calculation loops back and repeats to satisfy Eq. (15). 3.4 Mass transport and electric current JS, JV, η and tK + tA are calculated by substituting C’ and C” in Eqs. (1) and (2). Eq. (1) shows that ions in desalting cells are transported to concentrating cells by electro-migration λ i and ions move from the concentrating cells to the desalting cells by diffusion μ (C” – C’). Eq. (2) shows that solutions in desalting cells are transported to concentrating cells by electro-osmosis φ i and by volume osmosis ρ (C’ – C”). In the electrodialyzer, a part of the electric current does not pass through IEMs and it flows between electrodes through slots and ducts provided in the cells (cf. Fig. 2). i defined in Eqs. (1) and (2) is the effective current density, which does not include the electric current leakage. So, one defines the following effective electric current passing in the electrodialyzer I*(A). I* = iS (16) in which, S (cm2) is the membrane area. Superscript * denotes the effective electric current as control key. 3.5 Electric resistance of the cells (1) Electric resistance of a solution in a desalting cell and in a concentrating cell Diagonal net spacers are incorporated into the desalting cells and concentrating cells. They exert an influence on the electric resistance of both cells. The volume ratio of the spacer in the desalting cell ε’ and that of the concentrating cell ε” are defined by the following equations [30]. ' 8sin a π ε 'χ'θ' (17) " 8sin a π ε "χ"θ" (18)
8 in which, χ (cm) is the distance between spacer rods and θ (radian) is the crossing angle of the rods (Fig. 3) . Electric resistance of the desalting cell r’ and concentrating cell r” are given as: 2' '1' a rcm Ωε'κ (19) 2" "1 a rcm Ωε"κ" (20) Specific conductivity of a salt solution κ in Eqs. (19) and (20) is given by the following function of temperature T (Ԩ) and salt concentration C (g salt/kg solution) [34]. κ (S cm-1) = (0.9383 + 3.463×10-2T)×10-3C – (1.655 + 3.863×10-2T)×10-6C2 – (1.344 + 3.160×10-2T)×10-9C3 (21) (2) Electric resistance of a membrane pair Alternating current electric resistance of an IEM pair ralter is expressed by the following function of ρ [35]. ralter (Ωcm2) = ralter,K + ralter,A = 1.2323 ρ -(1/3) (22) in which, ralter,K and ralter,A are alternating electric resistance of a CEM and an AEM. ralter,K + ralter,A is defined as electric resistance of an IEM pair. Direct current electric resistance of a membrane pair rmemb is expressed by the following equation [18]. 2dire dire memb alter dire alter dire rr rcm rr rr ♭ ♭ Ω (23) r ♭ dire in Eq. (23) is measured by passing a direct electric current to a two-cell ED unit supplying low NaCl concentration solutions (specific conductivity κ ’) to both cells. rdire is measured by passing a direct electric current to above two-cell ED unit supplying a low NaCl concentration solution (specific conductivity κ ’) to a desalting side (cell) and a high NaCl concentration solution (specific conductivity κ ”) to a concentrating side (cell) and subtracting
9 the effect of membrane potential. (r ♭ dire/ralter) is expressed by the following empirical function of κ’. 2 log 0.3380 0.6386log ' 0.2961 log ' dire alter r r ♭ κκ (24) (κdire/r ♭ dire) is expressed by the following empirical function of κ’ and κ”. " 1.000 0.1359log dire dire r r ♭ κ κ' (25) 3.6 Electric Current Leakage In an electrodialyzer, a part of the electric current does not pass through IEMs and it flows between electrodes through slots and ducts provided in the cells. The structure of the cells is illustrated in Fig. 2. Electric current leakage is an ineffective and inevitable phenomenon which decreases current efficiency and increases substantial energy consumption. Here, one neglects the electric current leakage through direct connections between the cathode and anode by choosing an appropriate length of pipes [36]. As a simplification, one defines the overall electric resistance of the slots rs (Ω) and the ducts rd as follows: ,, , , 11 1 1 1 1 1 '" ' ' " " s s s s in s out s in s out rr r r r r r (26) ,, , , 111 1 1 '' "" d d in d out d in d out rr r r r (27) in which, electric resistance in the slots is given by the following equations: At the inlets of desalting cells; , ' '''''1 S sin in h rawn κε' (28) At the outlets of desalting cells;
16 In the concentrating cell; P”(W/pair) = P”cell + P”slot (66) Total pump driving power due to pressure drop Ppump is defined for a cell pair; Ppump (W/pair) = P’ + P” (67) The ratio of Ppump against IVcell is: '" pump cell cell PPP IV IV (68) 3.10 Limiting current density Limiting current density of an electrodialyzer (I/S)lim is given by the following equation [46]. 12 2 ' 12 3 1 2 lim '' 25 25 out nnu out out ITT ll l mmu C S (69) where l1 = 0.5950, l2 = 0.2731, l3 = 0.1310, m1 = 83.50, m2 = 24.00, n1 = 0.7846, n2 = 8.612× 10-3, T is temperature (℃) 4. Experimental 4.1 Materials and methods: sea water RO discharged brine RO discharged brine was pumped from the brine deposits of El Prat Sea Water Desalination Waterworks (ITAM-Aigues Ter Llobregat), Barcelona (Spain). Its average composition is shown in Table 1. Various experiments in a range of temperature from 16 to 27℃ and electric current densities from 3.0 to 6.0 A/dm2 were carried out. The experimental program lasted two years of operation in order to cover the lowest temperature of the Mediterranean Sea in winter time, with temperature up to 10℃ and the highest at summer time up to 28℃. Initial inlet RO discharged brine was oversaturated with calcium carbonate, magnesium carbonate and calcium magnesium carbonate, however, due to the use of anti-scalants on the RO step, scaling problems were not observed. The evolution of the saturation index for NaCl, KCl, MgCl2·6H2O, CaSO4·2H2O, SrSO4, CaCO3, MgCO3 and CaMg(CO3)2 as a function of the IEM-ED concentration process
17 indicates that the brine could be concentrated up to 4 times (approximately 250 g/l NaCl) without NaCl precipitation risk. 4.2 IEM-ED stack: pilot configuration and operation procedures The IEM-ED pilot plant has been described elsewhere [19, 20]. The IEM stack was a EURODIA AQUALIZER SV-10 with 50 cell pairs made of Neosepta cation-exchange membranes (CMB) and anion-exchange membranes (AHA) (1000 cm2 active surface area per membrane). The stack dimensions were 620x450x313 mm. The intermembrane distance was 0.43 mm, whereas linear flow velocity at the inlet of desalting and concentrating cells was around 10.8 cm/s. Photo 1 shows the structure of the cell (U-shape cell). Photo 2 shows the pilot plant. The brine flow rate through the IEM stack was 0.5 m3/h in both, the feeding stream and the concentrating stream compartments and 0.15 m3/h at the electrodes chambers. The feeding and the electrolyte circuits operated in a single-pass design to achieve higher current densities, minimize the problems of the increase of temperature in the cell and the precipitation of calcium sulphate in the feeding compartments. The concentrate stream was re-circulated until the maximum NaCl concentration was reached. Hydrochloric acid was added to keep the pH below 3 for the cathodic circuit, below 7 in the feeding circuit and below 5.5 in the concentrate circuit. Current densities were varied between 3 and 6 A/dm2. Inlet and outlet temperature were monitored during all the experiments. The RO discharged brine concentration process was monitored by in-line measurements of conductivity, temperature, pH, flow-rate, pressure, current intensity and voltage. Fig. 6 shows the diagram of the main components of the ED pilot plant and monitored parameters. 4.3 Analytical methodologies and chemical analysis Samples were taken from the concentrate tank, the inlet brine, and the feeding and concentrate flows leaving the stack every 2 hours. Conductivity and temperature of feeding and concentrate streams were monitored during operation to ensure that the concentration process was successful. Sodium chloride, sulphate, calcium and magnesium concentrations in the samples were analyzed. Chloride was determined potentiometrically through precipitation with AgNO3 and a silver chloride electrode (Methrom 721). Calcium and magnesium were determined by Atomic Absorption Spectrophotometry (Perkin Elmer Analyst 300). Sulphate was determined by ionic chromatography (Methrom 761 compact IC equipped with an Anion Dual 2-6.1006.100 column). Finally, sodium chloride was determined by electrically balancing the major ions of the solution.
18 5. Discussion Table 2 shows the specifications and operating conditions of the pilot plant electrodialyzer integrated with the imaginary I-shape cells. Pilot plant operation was carried out changing temperature. The computation elucidates the influence of temperature on the plant performance because the program consists of Eqs. (6), (21), (41), (50), (57), (64) and (69) in which temperature T is included. Computation was carried out by inputting the data in Table 2 into the ED program in Fig. 5. Table 3 gives the performance of the ED operation obtained by the experiment (C”NaCl, ENaCl) and the computation (C”NaCl, ENaCl, Vcell, α , IL/I, Ppump/IVcell, (I/S)lim). The computed data show that the current leakage IL/L is nearly three percent, the pump driving force Ppump/IVcell is ca. 1 – 2 percent and the limiting current density (I/S)lim is very high (over ten times of current density). However, the desalting ratio α is extremely low, thus the salt concentration at the outlets of desalting cells does not decrease sufficiently. C”NaCl and ENaCl obtained by the experiment are plotted against the computed data and are shown in Figs. 7 and 8, respectively. The correlation coefficients are R(r) = 0.553 for C”NaCl (Fig. 7) and R(r) = 0.863 for ENaCl (Fig. 8). These figures show that the experimental data are equivalent to the computed data and demonstrate the reasonability of the program. In order to increase the desalting ratio α in Table 3, the computation was carried out with decreasing the linear velocity at the inlets of desalting cells u’in and concentrating cells u”in from u’in = u”in = 10.8 cm/s to 1.0 cm/s keeping I/S = 4.0 A/dm2 and T = 25℃ (Table 4). Table 4 shows that α is increased from 0.046 (10.8/s) to 0.61 (1.0 cm/s), however, C”NaCl is decreased and ENaCl is increased with the decrease of the linear velocity. Changes in Table 4 are explained in Fig. 9. Salt concentration of RO discharged brine in this investigation is 69.36 g/dm3 and it is twice the concentration of seawater. Thus it is necessary to operate the electrodialyzer keeping α = 0.5 to reduce salt concentration of a desalted solution to seawater level. In Fig. 9, α = 0.5 is realized by keeping the linear velocity u = 1.18 cm/s at I/S = 4.0 A/dm2 and T = 25℃. However, in this operating condition C”NaCl is decreased to 197.3 g/dm3 and ENaCl is increased to 186.4 kWh/tNaCl. In Fig. 10, Line A (Mark ○) shows C”NaCl vs. ENaCl (Table 4, Fig. 9) computed inputting I/S = 4 A/dm2, T = 25℃ and u’in = u”in = 1 – 10.8 cm/s. Line B (Mark △) is computed inputting I/S = 2 – 6 A/dm2, T = 25℃ and u’in = u”in = 10.8 cm/s. Line C (Mark □) is computed inputting I/S = 2 – 6 A/dm2, T = 25℃ and α = 0.5. Mark ▲ is the data of the pilot plant (EURODIA AQUALIZER) operation obtained in this investigation (Section 4 Experimental) and they are introduced from Table 3. Mark ■ shows data by months reported from the salt manufacturing plant operation to produce edible salt in Japan [47]. The plant specifications and operating conditions are; number of electrodialyzers: 17, total cell pair number: 30,000 pairs, total membrane area: 54,621 m2, average current density:
19 2.66 A/dm2, average temperature: 23.5 ℃ (T = 16.0 – 28.2℃). The Target displayed in the figure (C”NaCl > 200 NaCl g/dm3, ENaCl < 120 kWh/t NaCl) is the situation to occupy a competitive position in the salt market for industrial use [48]. In Fig. 10, the pilot plant is operated at T = 16 - 27℃; Mark ▲, which is comparable to the Line B (Mark △, T = 25℃). The pilot plant should be operated at lower linear velocity u’in to keep α = 0.5 (Line C, Mark □). u’in at α = 0.5 is plotted against I/S and shown in Fig. 11. The pilot plant should be operated according to Fig. 11 taking into account the effect of temperature on α . However, this operation induces the receding of the plots from the target (C”NaCl is decreased and ENaCl is increased). The data of the pilot plant operation (Mark ▲) fluctuate largely due to temperature changes and experimental errors. These fluctuations are due to long time pilot plant operations over a period of two years. However, they must be plotted on Line B using the algorithm of the computation if the temperature is adjusted to 25℃ and the experimental errors are removed. Further it should be noted that Line B is nearer to the Target compared to the data of salt manufacturing plant (Mark ■) to produce edible salt. Such an advantage of the pilot plant operation is also recognized if the operation is done keeping α = 0.5 (Line C, Mark □). Thus NaCl produced in the RO discharged brine ED is assumed to be sufficiently competitive in the edible salt market. Fig. 12 shows the target of this investigation to establish the zero discharge seawater utilization process. By keeping α = 0.5 in ED and returning the desalted solution from ED to RO, water recovery of RO is increased. The product of this process is: drinking water from RO, edible salt and bittern (byproduct) from evaporation (EV), and Cl2, H2 and NaOH from electrolysis (EL). H2 is supplied to fuel cells to generate electric power which is supplied to EL [49]. In order to establish this process, it is necessary to advance ED technology further to increase NaCl concentration and decrease energy consumption. 6. Conclusions Computer simulation program is fundamentally applied to discuss the performance of an electrodialyzer incorporated with I-shape cells. In this investigation, the program is developed as it is applicable to U-shape cells by assuming the imaginary I-shape cells. The program is applied to compute not only general performance of an electrodialyzer such as mass transport and energy consumption but also specific features such as electric current leakage and pressure drop. The computed energy consumption and salt concentration of the concentrate are equivalent to the data obtained from the ED pilot plant operation, thus the reasonability of the program is confirmed. The differences between the computed values and experimental values are due to
20 fluctuations of experimental conditions such as temperature etc. These sources of errors must be taken into account in the next investigation. In order to reduce salt concentration to seawater level for environmental conservation, it is necessary to decrease linear velocity at the inlets of desalting cells and keep the desalting ratio in 0.5. This operating technique decreases salt concentration of concentrated solutions and increases energy consumption. In spite of this operating circumstance, NaCl produced from the RO discharged brine by means of ED is competitive in the edible salt market. However, in order to produce NaCl for industrial use, it is necessary to advance ED technology further to increase NaCl concentration and decrease energy consumption. ACKNOWLEDGEMENTS The Center for the Development of Industrial Technology (CDTI), the Ministry of Economy and Innovation (MINECO) through the ZERODISCHARGE project (CTQ-2011-26799) and the Research Agency of Catalunya (Project 2014SGR50) have supported this project. M. Reig thanks to MINECO her PhD grant BES-2012-051914. We would also like to acknowledge to the El Prat Desalination plant (ITAM-ATLL) and to the SOLVIN Martorell teams for their valuable support. REFERENCES [1] N. Voutchkov, Overview of seawater concentrate disposal alternatives, Desalination 273 (2011) 205-219. [2] MEDRC, Assessment of the Composition of Desalination Plant disposal Brine (Project NO. 98-AS-0.26), Middle East Desalination Research Center (MEDRC), Oman, 2002. [3] H. Khordagui, Environmental impacts of power-desalination on the gulf marine ecosystem, In: Khan et al. (Eds.), The gulf Ecosystem: Health and Sustainability, Backhuys Publishers, Leiden, 2002. [4] UNEP/MEDPOL: Sea Water Desalination in the Mediterranean: Assessment and Guidelines, MAP Technical Report Series No. 139, United Nations Environmental Program (UNEP), Mediterranean Action Plan (MAP), Program for the Assessment and Control of Pollution in the Mediterranean region (MEDPOL), Athens, Greece, 2003. [5] AMBAG, Desalination Feasibility Study in the Monterey Bay Region, prepared for the
21 Association of Monterey Bay Area Governments (AMBAG), 2006. http://ambag.org/ [6] S. Lattermann, T. Hopner, Environmental impact and impact assessment of seawater desalination, Desalination 220 (2008) 1-15. [7] E. Gacia, O. Invers, M. Manzanera, E. Ballesteros, J. Romero, Impact of the brine from a desalination plant on shallow seagrass (Posidonia Oceanica) meadow, Estuarine, Coastal and Shelf Science 72 (2007) 579-590. [8] R. Danoun. Desalination Plants, Potential Impacts of Brine Discharge on Marine Life, The Ocean Technology Group., University of Sydney, Australia, 2007. [9] M. Latorre, Congreso Iberico de Gestion y Planificacion del Agua, Costes Economicos y Medio Ambientals de la Desalacion de Aqua de Mar, Tortosa, 2004. [10] H. Qdais, Environmental impacts of the mega desalination project: The Red Dead Sea conveyor, Desalination 220 (2008) 16-23. [11] R. Kempton, D. Maccioni, S. M. Mrayed, G. Leslie, Thermo dynamic efficiencies and GHG emissions of alternative desalination process, Water Science and Technology: Water Supply 10 (2010) 416-427. [12] A. Pérez-González, A. M. Urtiaga, R. Ibáñez, I. Ortiz, State of the art and review on the treatment technologies of water reverse osmosis concentrates, Water Research 46 (2012) 267-283. [13] P. Xu, T. Y. Cath, A. P. Robertson, M. Reinhard, J. O. Leckie, J. E. Drewes, Critical review of desalination concentrate management, treatment and beneficial use, Environmental Eng. Sci. 30 (2013) 502-514. [14] A. D. Thomas, Zero Discharge Seawater Desalination: Integrating the Production of Freshwater, Salt, Magnesium, and Bromine, Desalination and Water Purification Research and Development Program Report No. 111, Agreement No. 98-FC-81-0054, U. S. Department of the Interior, Bureau of Reclamation, May, 2006. [15] Y. Zhang, K. Ghyselbrecht, B. Meesschaert, L. Pinoy, B. Van der Bruggen, Electrodialysis on RO concentrate to improve water recovery in wastewater reclamation, J. Membr. Sci. 378 (2011) 101-110. [16] A. T. K. Tran, Y. Zhang, N. Jullok, B. Messchaert, L. Pinoy, B. Van der Bruggen, RO concentrate treatment by a hybrid system consisting of a pellet reactor and electrodialysis, Chem. Eng. Sci. 79 (2012) 228-238. [17] R. K. McGoven, S. M. Zubair, J. H. Lenhard V, The benefits of hybridizing electrodialysis with reverse osmosis, J. Membr. Sci. 469 (2014) 326-335. [18] Y. Tanaka, R. Ehara, S. Itoi, T. Goto, Ion-exchange membrane electrodialytic salt production using brine discharged from a reverse osmosis seawater desalination plant, J. Membr. Sci. 222 (2003) 71-86.
22 [19] S. Casas, N. Bonet, C. Aladjem, J. L. Cortina, E. Larrotcha, L. V. Cremades, Modelling sodium chloride concentration from seawater reverse osmosis brine by electrodialysis: Preliminary results, Solvent Extraction and Ion Exchange 29 (2011) 488-508. [20] M. Reig, S. Casas, C. Aladjem, C. Valderrama, O. Gibert, F. Valero, C. M. Centeno, E. Larrotcha, J. L. Cortina, Concentration of NaCl from seawater reverse osmosis brines for the chlor-alkali industry by electrodialysis, Desalination 342 (2014) 107-117. [21] C. Jiang, Y. Wang, Z. Zhang, T. Xu, Electrodialysis of concentrated brine from RO plant to produce coarse salt and freshwater, J. Membr. Sci. 450 (2014) 323-330. [22] G. Belfort, J. A. Daly, Optimization of an electrodialysis plant, Desalination 8 (1970) 153-166. [23] M. Avriel, N. Zelighter, A computer method for engineering and economic evaluation of electrodialysis plant, Desalination 10 (1972) 113-146. [24] H. J. Lee, F. Sarfert, H. Strathmann, S. H. Moon, Designing of an electrodialysis desalination plant, Desalination 142 (2002) 267-286. [25] P. Moon, G. Sandi, D. Stevens, R. Kizilel, Computational modeling of ionic transport in continuous and batch electrodialysis, Sep. Sci. Technol. 29 (2004) 2531-2555. [26] M. Fidaleo, M. Moresi, Optimal strategy to model the electrodialytic recovery of a strong electrolyte, J. Membr. Sci. 260 (2005) 90-111. [27] M. Sadrzadeh, A. Kaviani, T. Mohammadi, Mathematical modeling of desalination by electrodialysis, Desalination 206 (2007) 534-549. [28] V. V. Nikonenko, N. D. Pismenskaya, A. G. Itoshin, V. I. Zabolotsky, A. A. Shudrenko, Description of mass transfer characteristics of ED and EDI apparatus by using the similarity theory and computation method, Chem. Eng. Process 47 (2008) 1118-1127. [29] E. Brauns, W. De Wide, B. Van den Bosch, P. Lens, L. Pinoy, M. Empsten, On the experimental verification of an electrodialysis simulation model for optimal stack configuration design through solver software, Desalination 249 (2009) 1030-1038. [30] Y. Tanaka, Ion-exchange membrane electrodialysis program and its application to multi-stage continuous saline water desalination, Desalination 301 (2012) 10-25. [31] Y. Tanaka, Ion Exchange Membranes, 2nd edition: Fundamentals and Applications, Elsevier, Amsterdam (2015). http://booksite.elsevier.com/978044463319/ [32] Y. Tanaka, Irreversible thermodynamics and overall mass transport equation in ion-exchange membrane electrodialysis, J. Membr. Sci. 281 (2006) 517-531. [33] Y. Tanaka, Ion-exchange membrane electrodialysis for saline water desalination and application to seawater concentration, Ind. Eng. Chem. Res. 50 (2011) 7494-7503. [34] M. Akiyama, Y. Tanaka, Sea Water Science Research Laboratory, Technical Report, No. 3-22, p. 13, Japan Tobacco & Salt Public Corp. (1992).
23 [35] Y. Tanaka, Ion-exchange membrane electrodialysis of saline water and its numerical analysis, Ind. Eng. Chem. Res. 50 (2011)10765-10777. [36] R. Yamane, M. Ichikawa, Y. Mizutani, Y. Onoue, Concentrated brine production from sea water by electrodialysis using ion exchange membranes, Ind. Eng. Chem. Process Des. Dev. 8 (1969) 159-165. [37] J. R. Wilson, Demineralization by Electrodialysis, Buther-worth Scientific Publication, London, pp. 265-274 (1969). [38] H. S. Harned, B. B. Owen, Physical Chemistry of Electrolyte Solutions, p. 726, Reinhold (1998). [39] Y. Mizutani, R. Yamane, T. Sata, T. Izuo, Permselectivity treatment of a cation-exchange membrane, JP S46-42083 (1971). [40] K. Mihara, T. Misumi, H. Yamauchi, Y. Ishida, Production of a cation-exchange membrane having excellent specific permeability between cations, JP S47-3081 (1972). [41] H. Hani, H. Nishimura, Y. Oda, Anion-exchange membrane having permselectivity between anions, JP S36-15258 (1961). [42] K. Mihara, T. Misuni, H. Yamauchi, Y. Ishida, Anion-exchange membrane having excellent specific permeability between anions, JP S45-19980, S45-30693 (1970). [43] C. C. Zimmer, V. Kotte, Effects of spacer geometry on pressure drop, mass transfer, mixing behavior, and residence time distribution, Desalination 104 (1996) 129-134. [44] P. Tsiakis, L. G. Papageorgiou, Optimum design of an electrodialysis brackish water desalination plant, Desalination 173 (2005) 173-186. [45] K. Sato, T. Matsuo, Seawater Handbook, Soc. Sea Water Sci. Jpn., p. 10 (1974). [46] Y. Tanaka, Mass transport in ion-exchange membranes, In: Encyclopedia of Membrane Science and Technology (Eds. M. V. Hoek, V. V. Tarabara), John Wiley & Sons, Inc. (2013). [47] Salt manufacturing plant technical report, Salt Industry Center, Jpn. (1998). [48] T. Fujita, Current challenges of salt production technology, Bull. Soc. Sea Water Sci. Jpn. 63 (2009) 15-20. [49] S. Bebelis, K. Bouzek, A. Cornell, M. G. S. Ferreira, G. H. Kelsall, F. Lapique, C. Ponce de Leon, M. A. Rodrigo, F. C. Walsh, Highlight during the development of electrochemical engineering, Chem. Eng. Res. Des. 91 (2013) 1998-2020. http://www.cleanenergyactionproject.com NOMENCLATURES
24 a flow-pass thickness in a desalting and a concentrating cell (cm) b flow-pass width in a desalting and a concentrating cell (cm) C electrolyte concentration (eq cm-3, eq dm-3, g dm-3) d solution density dH hydraulic diameter (cm) E energy consumption (kWh t-1) F Faraday constant (As eq-1) h length of a slot and a duct (cm) i effective current density (Acm-2, Adm-2) I total electric current (A) I* effective electric current (A) IL electric current leakage (A) I/S average current density (Acm-2, Adm-2) (I/S)lim limiting current density (Acm-2) JS ion flux across a membrane pair (eq cm-2s-1), (t m-2h-1) JV solution flux across a membrane pair (cm s-1), (m h-1) l flow-pass length in a desalting and a concentrating cell (cm) n number of slots in a cell N number of cell pairs in a stack p NaCl purity in a concentrate (g/g) P output (t m-2h-1); driving power (W/pair) Ppump pump driving power (W/pair) Q solution volume rate (m3min-1) r electric resistance (Ωcm2) ralter altering current electric resistance (Ωcm2) rcellpair electric resistance of a cell pair (Ωcm2) rdire direct current electric resistance (Ωcm2) rmemb direct current electric resistance of a membrane pair (Ωcm2) rNa Na + ion concentration ratio in concentrate (eqv./eqv.) R gas constant (JK -1mol-1) S ion-exchange membrane area (cm2) t transport number of ions in a membrane T temperature (℃, K) u linear velocity in desalting and concentrating cells (cm s-1) Vcell cell voltage (V pair-1)
25 Vmemb membrane potential (V pair-1) V Ω Ohmic potential (V pair-1) w width of a slot and a duct (cm) Greek letters α desalting ratio γ activity coefficient of electrolytes in a solution Δ H head loss (m) Δ P pressure drop (Pa) ε volume ratio of a spacer in a desalting and a concentrating cell η current efficiency η p pump efficiency κ specific conductivity of a solution (mS cm-1) θ crossing angle of spacer rods (radian) λ overall transport number of a membrane pair (eq A-1s-1) μ overall solute permeability of a membrane pair (cm s-1); viscosity coefficient (g cm-1s-1) ρ overall volume osmotic permeability of a membrane pair (cm4eq-1s-1) τ thickness of an ion-exchange membrane (cm) φ overall electro-osmotic permeability of a membrane pair (cm3A-1s-1) χ distance between spacer rods (cm) Subscripts A anion-exchange membrane cell cell d duct in inlet K cation-exchange membrane out outlet s, slot slot Superscripts ‘ desalting cell “ concentrating cell * control key # overall
32 EDSTACK ConcentratedTan k Concentratetan kfill‐up Cl 2tr eatment H2tr eatment DRAIN Anolyte Catholyte SWRObrine Concentra te flow Di luate +‐ FI FI Flo w FlowPre ss ur e pH Pres sure Flow Cond uctivi ty Te mp er at u re Co n d uc ti v i ty Te mper ature pH Flow Co n d uc t i v i ty Temperature Fig. 6 Diagram of the main components of the ED pilot plant and parameters monitored.
33 150 175 200 225 250 275 300 150 175 200 225 250 275 300 R(r) = 0.553 C" NaCl,exp (NaCl g/dm 3 ) C" NaCl,comp (NaClg/dm 3 ) Fig. 7 NaCl concentration in the concentrated solution.
34 100150200250300350 100 150 200 250 300 350 R(r) = 0.863 E NaCl,exp (kWh/tNaCl) E NaCl,comp (kWh/tNaCl) Fig. 8 Energy consumption.
35 0123456789101112 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0123456789101112 170 175 180 185 190 195 200 205 210 215 220 α E NaCl (kWh/tNaCl) C" NaCl (g/dm 3 ) u = u' in = u" in (cm/s) E NaCl =186.4 kWh/tNaCl C" NaCl =197.3 g/dm 3 u =10.8 cm/s u =1.18 cm/s α =0.5 α E NaCl C" NaCl Fig. 9 Influence of linear velocity to NaCl concentration and energy consumption. I/S = 4 A/dm2, T = 25℃
36 50 100150200250300 120 140 160 180 200 220 240 260 280 300 C" NaCl (g/dm 3 ) E NaCl (kWh/t NaCl) C BA α = 0.5 6 A/dm 2 5 4 3 2 u' in = u" in = 10.8 cm/s 1 cm/s = 10.8 cm/s u' in = u" in Target Fig. 10 Relationship between NaCl concentration and energy consumption to produce one ton of NaCl. Program computation ○ 4 A/dm2, 25℃, u’in = u”in = 1 – 10.8 cm/s; Line A △ 2 – 6 A/dm2, 25℃, u’in = u”in = 10.8 cm/s; Line B □ 2 – 6 A/dm2, 25℃, α = 0.5; Line C Plant operation ▲ Pilot plant operation (EURODIA AQUALIZER, Spain) ■ Salt manufacturing plant operation (Seawater electrodialyzer, Japan)
37 012345678910 0.0 0.5 1.0 1.5 2.0 2.5 3.0 u' in, α =0.5 (cm/s) I/S (A/dm 2 ) Fig. 11 Linear velocity at the inlet of desalting cells at desalting ratio α = 0.5. T = 25℃
38 Cl2 H2 RO EV Drinkin g Concentrated Water Seawater water brine Bittern Salt Concentrated ED crystal Saturated brine DS NaCl NaOH Saturated brine PU Water Desalted solution Salt concentration; seawater level Edible salt EL Fig. 12 Zero discharge seawater utilization process RO; Reverse osmosis EV; Evaporation EL; Electrolysis ED; Electrodialysis DS; Dissolution PU; Purification
39 Table 1 Average of the RO discharged brine from the ITAM-El Prat Desalination water works (Barcelona, Spain) Major components1 Concentration (g/L) Minor components2 Concentration (mg/L) Cl- 38.8±0.4 Si < 1 Br- 0.13±0.06 Al < 0.5 SO42- 5.41±0.2 Fe < 0.2 Mg2+ 2.64±0.2 Ba < 0.2 Ca2+ 0.83±0.04 Ni 0.07±0.02 K+ 0.75±0.05 Cu 0.03±0.01 Na + 20.8±0.3 Mn 0.01±0.01 Sr2+ 0.016±0.003 Cr 0.007±0.003 1 Concentration values correspond to the ionic forms 2 Concentration values correspond to the total element concentration
40 Table 2 Specifications and operating conditions of the pilot plant electrodialyzer integrated with imaginary I-shape cells. Flowp ass thickness in a desaltin g and a concentratin g cell: a = a' = a " 0.043 c m Flowp ass width in a desaltin g and a concentratin g cell: b10 c m Flowp ass len g th in a desaltin g and a concentratin g cell: l 100 c m Membrane area: S1000 c m 2 Thickness of a cation-exchange membrane: τ K0.018 cm Thickness of an anion-exchange membrane: τ A0.015 cm Slot and duct number in a desaltin g cell: n' 1 Slot and duct width in a desaltin g cell: w' 3c m Slot and duct len g th in a desaltin g cell: h' 2c m Slot and duct number in a concentratin g cell: n" 1 Slot and duct width in a concentratin g cell: w" 3c m Slot and duct len g th in a concentratin g cell: h " 2c m Rod distance of a s p acer: χ 0.1 c m Crossin g an g le of rods of a s p acer: θπ /2 radia n Number of cell p airs: N 50 p airs Linear velocity at the inlet of desalting cells: u' in 10.8 cm/s Linear velocity at the inlet of desalting cells: u" in 10.8 cm/s Salt concentration at the inlets of desalting cells (RO discharged brine): C' in 69.36 g/dm3 Current density: I/S 3.0, 3.5, 4.0, 4.5, 5.0, 6.0 A/d m 2 Tem p erature: T 16 - 27 ℃
41 Table 3 Performance of RO discharged brine electrodialysis: experiments and computations No. I/S T C"NaCl ENaCl C" NaCl ENaCl Vcell αIL/I P pump /IVcell (I/S) lim A/d m 2℃NaCl g /d m 3kWh/NaCl t NaCl g /d m 3kWh/NaCl t V/pair A/d m 2 1 6.0 27 244 244 217.5 248.8 0.4004 0.07220 0.03482 0.007072 91.04 2 6.0 20 245 296 238.1 257.4 0.4278 0.07358 0.03248 0.007536 78.25 3 5.0 27 203 189 208.2 213.6 0.3428 0.58860 0.03462 0.009655 92.23 4 5.0 20 246 257 228.4 220.7 0.3658 0.06012 0.03237 0.010284 79.29 5 4.5 18 219 264 229.3 204.8 0.3422 0.05384 0.03165 0.012481 76.41 6 4.0 25 210 199 202.0 179.1 0.2892 0.04605 0.03368 0.014372 89.47 7 4.0 17 178 197 226.3 187.2 0.3137 0.04739 0.03124 0.015329 75.26 8 3.5 27 185 117 190.1 159.7 0.2550 0.03929 0.03406 0.017659 93.97 9 3.0 18 176 155 207.1 147.3 0.2449 0.03416 0.03120 0.024645 77.86 10 3.0 16 176 157 213.8 149.5 0.2507 0.03447 0.03064 0.024963 74.57 Experiment Computation Table 4 Influence of linear velocity to the performance of RO discharged brine electrodialysis. I/S = 4.0 A/dm2 , T = 25 ℃ u' in = u"in C" NaCl ENaCl Vcell αIL/I Ppump /IVcell (I/S) lim cm/s NaCl g /dm3kWh/NaCl t V/pair A/dm2 10.8 202.0 179.1 0.2892 0.04605 0.03368 0.014372 89.47 10.0 202.0 179.1 0.2893 0.04980 0.03367 0.012321 88.11 8.0 201.8 179.3 0.2896 0.06257 0.03360 0.007883 83.13 6.0 201.6 179.5 0.2900 0.08414 0.03350 0.004432 75.39 4.0 201.2 180.1 0.2910 0.12841 0.03328 0.001967 63.85 2.0 199.7 182.2 0.2944 0.27118 0.03258 0.000489 45.14 1.5 198.6 183.9 0.2974 0.37578 0.03209 0.000274 37.23 1.2 197.4 186.2 0.3010 0.48921 0.03156 0.000174 30.31 1.0 196.2 189.0 0.3058 0.61284 0.03102 0.000120 23.54