scieee AI-readable full text Open interactive document viewer

Validation of direct cortical stimulation in presurgical evaluation of epilepsy

Ley, Miguelq,Principe, Alessandro,Langohr, Klaus,Zucca, Riccardo,Rocamora, Rodrigo

Abstract

Objective Direct cortical stimulation (DCS) is standard for intracranial presurgical evaluation in drug-resistant epilepsy (DRE). Few studies have reported levels of concordance between spontaneous seizure generators and triggered seizures during DCS. The present work reports validity measures of DCS for detecting the seizure onset zone (SOZ) during stereoelectroencephalography (SEEG). Methods We evaluated all patients who underwent SEEG evaluation at our epilepsy center between 2013 and 2019. Data were analyzed using contingency tables. Validity measures of the diagnostic test were computed for all patients evaluated with DCS and for seizure free patients. Results Fifty-eight consecutive patients were evaluated through DCS. One hundred seventy-three clinical seizures were elicited with DCS. Electroclinical identical to spontaneous seizures were considered true positive (TP) seizures. They showed a high specificity (96.9%) for detecting the SOZ in patients that remained seizure free one year after treatment. Sensitivity was low (23.0%), and a high percentage of false-negative stimulations was documented in the SOZ. The accuracy was 87.9%. Conclusions DCS is a technique with high specificity but a low sensitivity for the localization of the SOZ. The DCS validity measures need to be known when considered for surgical decisions. The interpretation of DCS-triggered seizures and the differentiation of true-positive vs false-positive seizures should be carefully evaluated. Significance DCS seizure triggering is highly specific for SOZ localization.

Full text

Journal Pre-proofs Validation of direct cortical stimulation in presurgical evaluation of epilepsy Miguel Ley, Nazaret Peláez, Alessandro Principe, Klaus Langohr, Riccardo Zucca, Rodrigo Rocamora PII: S1388-2457(22)00169-9 DOI: https://doi.org/10.1016/j.clinph.2022.02.006 Reference: CLINPH 2009879 To appear in: Clinical Neurophysiology Received Date: 26 July 2021 Revised Date: 20 January 2022 Accepted Date: 11 February 2022 Please cite this article as: Ley, M., Peláez, N., Principe, A., Langohr, K., Zucca, R., Rocamora, R., Validation of direct cortical stimulation in presurgical evaluation of epilepsy, Clinical Neurophysiology (2022), doi: https:// doi.org/10.1016/j.clinph.2022.02.006 This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain. © 2022 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved. 1 Validation of direct cortical stimulation in presurgical evaluation of epilepsy Miguel Leya,b; Nazaret Peláeza; Alessandro Principea,b,d; Klaus Langohrb,c; Riccardo Zuccaa,b,*; Rodrigo Rocamoraa,b,d,* a. Epilepsy Reference Centre, Department of Neurology, Hospital del Mar, Barcelona, Spain. Member of the European Reference Network EpiCARE b. Hospital del Mar Medical Research Institute, Barcelona, Spain c. Universitat Politècnica de Catalunya-Barcelona TECH, Barcelona, Spain d. Faculty of Health and Life Sciences, Universitat Pompeu Fabra, Barcelona, Spain * Equal contribution. Corresponding author: Rodrigo Rocamora MD, PhD Department of Neurology, Hospital del Mar Passeig Marítim 25-29, Barcelona 08003, Spain Phone number: +34 932483727 Fax: +34 932483236 E-mail: [email protected] E-mails co-authors: [email protected]; [email protected]; [email protected]; [email protected]; [email protected] 2 Abstract Objective: Direct cortical stimulation (DCS) is standard for intracranial presurgical evaluation in drug-resistant epilepsy (DRE). Few studies have reported levels of concordance between spontaneous seizure generators and triggered seizures during DCS. The present work reports validity measures of DCS for detecting the seizure onset zone (SOZ) during stereoelectroencephalography (SEEG). Methods: We evaluated all patients who underwent SEEG evaluation at our epilepsy center between 2013 and 2019. Data were analyzed using contingency tables. Validity measures of the diagnostic test were computed for all patients evaluated with DCS and for seizure free patients. Results: Fifty-eight consecutive patients were evaluated through DCS. One hundred seventy-three clinical seizures were elicited with DCS. Electroclinical identical to spontaneous seizures were considered true positive (TP) seizures. They showed a high specificity (96.9%) for detecting the SOZ in patients that remained seizure free one year after treatment. Sensitivity was low (23.0%), and a high percentage of false-negative stimulations was documented in the SOZ. The accuracy was 87.9%. Conclusions: DCS is a technique with high specificity but a low sensitivity for the localization of the SOZ. The DCS validity measures need to be known when considered for surgical decisions. The interpretation of DCS-triggered seizures and the differentiation of true-positive vs falsepositive seizures should be carefully evaluated. Significance: DCS seizure triggering is highly specific for SOZ localization. Keywords: epilepsy, direct cortical stimulation, surgery, drug-resistant, stereoelectroencephalography. 3 Highlights DCS is a technique with high specificity (96.9%) for defining the seizure-onset zone in the presurgical evaluation of drug-resistant epilepsy. DCS has low sensitivity (23.0%) due to a high percentage of false-negative stimulations obtained during SEEG monitoring. The resection of the contacts involved in eliciting true positive seizures is associated with a good surgical outcome. Abbreviations: Direct cortical stimulation (DCS); drug-resistant epilepsy (DRE); seizure onset zone (SOZ); stereoelectroencephalography (SEEG); true positive (TP); epileptogenic zone (EZ); temporal lobe epilepsy (TLE); 18-fluorodexyglucose positron emission computerized tomography (18FDG-PET scan); ictal-interictal single photon emission computerized tomography (SPECT); digital subtraction co-registered over the anatomical image (SISCOM); voxel-based morphometry (VBM); and electrical source neuroimaging (ESI), Video-EEG (VEEG); robotic stereotactic surgical assistant ROSA; computerized tomography (CT-scan); radiofrequency thermocoagulation (RF-TC); anti-seizure medication (ASM); IQR interquartile range. 4 1. Introduction The direct cortical stimulation (DCS) of the human brain is a widely used technique employed during intracranial explorations of patients with DRE (Bancaud et al., 1974; Bancaud and Chauvel, 1986; Kahane et al., 2006; Trébuchon and Chauvel, 2016; Wieser et al., 1979; Chauvel et al., 1993). It was first described by Cushing in 1909 (Cushing, 1909) and then applied by Penfield, Jasper and Foerster for intraoperative functional mapping (Foerster and Penfield, 1930; Penfield and Jasper; 1954). Whereas Bancaud and Talairach employed DCS to localize the epileptogenic zone (EZ), DCS has also been extensively used to map the human brain’s eloquent cortex (Stephani and Lüders, 2011). The seizure onset zone (SOZ) is an electroclinical concept based on intracerebral electroencephalographic (iEEG) recordings and is defined as the exact anatomical point of electrical origin of seizures. The SOZ is interconnected with the initial configuration area, necessary to generate seizures (Bancaud et al. 1962, Bancaud and Chauvel 1986, Buser et al. 1973, Talairach and Bancaud 1973, Talairach et al., 1974). On the other hand, the American school defines the EZ as the minimal area of cortex that must be resected to produce seizure freedom, which includes the SOZ but also the irritative zone, the symptomatogenic zone, the epileptogenic lesion, and the functional deficit zone (Rosenow and Lüders, 2001). Therefore, this is a post-hoc definition, only verified after surgery. In contrast, the concept of EZ proposed by the French school is based primarily on the electrophysiological analysis of epileptic seizures, which is then translated into anatomical terms. This definition is mainly derived from an electroclinical working hypothesis that excludes interictal discharges or the epileptogenic lesion a priori (Kahane et al., 2006). The primary objectives of DCS are the definition of the EZ and cortical mapping (Bank et al., 2014, Kovac et al., 2016, Huang et al., 2019; Boido et al., 2014; Dionisio et al., 2019; Sarubbo et al., 2020; David et al., 2008, 2010 and 2013; Rahimpour et al., 2019; Boyer et al., 2020; Pizarro et al., 2018; Bartolomei et al., 2004; Kahane et al., 2003; Ojemann et al., 2008). For the evaluation of the EZ, most centers use high-frequency stimulations (50 Hz), while others also apply lowfrequency pulses at 1 Hz for longer periods. The aim is to stimulate seizures in highly epileptogenic cortical areas (Voskuyl et al., 1989; Corley et al., 2017; Jacobs et al., 2010). In the early ’90s, studies reported a high concordance of spontaneous and electrically triggered seizures (Bernier et al., 1990). Results were superior for patients with unilateral foci and temporal lobe epilepsy (TLE). 5 From the electrophysiological perspective, DCS can cause seizures or after-discharges (ADs), defined as epileptiform discharges evoked by and outlasting the stimulation. However, it was demonstrated that ADs were not a reliable predictor of the SOZ localization as they were documented in non-epileptic tissue (Wyler and Ward, 1981; Gollwitzer et al., 2018). Still, it was suggested that they could represent a marker of tissue epileptogenicity. In addition, ADs can lead to the erroneous localization of cortical functions if they disrupt regular brain activity (Blume et al., 2004). From a semiology perspective, DCS can elicit clinical seizures (typical or atypical for the patient) or auras without an associated electrical pattern (Ostroswsky et al., 2002; Halgren et al., 1978). The anatomical localization of the stimulus-induced clinical auras can aid localize the symptomatogenic zone and help locate the SOZ (Schulz et al., 1997; Chassoux et al., 2000). Finally, electrical stimulation can also be used for brain function mapping, but this topic is beyond the scope of this publication. During the bedside evaluation, a careful double check should be performed. On the one hand, the electrical pattern of stimulated seizures should be the same as that of spontaneous seizures. On the other hand, the semiology recorded must also be identical. If these two requirements are met, they are defined as electroclinically identical to the patient’s spontaneous seizures (Perrucca et al., 2014; Singh et al., 2015; Kämpfer et al., 2020). Recent research has focused on the effectiveness and the clinical utility of DCS in delineating the EZ and the eloquent cortex. However, our study focuses on the validity measures of this technique for SOZ localization to be used during the presurgical decision-making process. 2. Materials and Methods Study design and patient selection We conducted a retrospective analysis of consecutive patients evaluated by SEEG between January 2013 and December 2019 who have undergone DCS. All patients were evaluated at the Epilepsy Monitoring Unit of Hospital del Mar, Barcelona, a national reference center for refractory epilepsy and member of the European Reference Network EPI-Care. After a non-invasive diagnosis, the decision to perform an SEEG for diagnostic purposes was taken at our multidisciplinary case discussion meeting. 6 Ethics committee The Ethics Committee in Clinical Research (CEIC-Parc de Salut Mar) examined and approved the protocol. All patients signed informed consent to use their data in this protocol. The study complied with good clinical practices as required by the principles of the 2008 Declaration of Helsinki of the World Medical Association and current legislation on personal data protection (Organic Law 3/2018, of December 5, on the Protection of Personal Data and the Guarantee of Digital Rights). Presurgical Diagnosis The diagnostic protocol included a high-resolution magnetic resonance brain imaging (3T MRI) (3T Philips Achieva, Koninklijke Philips N.V., Netherlands) and extensive neuropsychological evaluation. Based on presurgical evaluation needs, we used brain 18-fluorodeoxyglucose positron emission computerized tomography [(18FDG]-PET scan), ictal-interictal single-photon emission computerized tomography (SPECT) with digital subtraction coregistered over the anatomical image (SISCOM), voxel-based morphometry (VBM), and electrical source neuroimaging (ESI). Video-EEG (VEEG) recordings were collected using a standard clinical EEG system (XLTEK®, Natus Medical), and the implantation strategies were decided based on the semiological, electrophysiological, and neuroradiological data. The patients were implanted with deep electrodes using the robotic stereotactic surgical assistant ROSA® (Medtech, France). Implantation procedure and postprocessing imaging The electrode targets and trajectories were established exclusively for clinical reasons using a stereo-electroencephalographic approach. The number of electrodes varied between patients with 5-18 contacts each (diameter: 0.8 mm; contacts 2 mm long, 1.5 mm apart) (DixiMédical, France). After implantation, electrodes’ localization was determined by co-registering the high-definition head CT scan (General Electrics®, Boston, MA, USA) subtracted over the pre-implantation 3T MRI. Each contact was located and reviewed in three dimensional (3D) projections (3D Slicer, http://www.slicer.org, Surgical Planning Laboratory, Harvard University, Boston, MA, USA) to determine the exact anatomical localization. Additionally, a pre-resectional angio-3T MRI was coregistered with the post-implantation computerized tomography (CT-scan) for vessel avoidance during radiofrequency thermocoagulation (RF-TC). The SEEG recordings were visually inspected 7 by three epileptologists (ML, RR and AP) to determine the area involved in the SOZ. We analyzed the contacts involved in the first three seconds from the seizure onset. The seizure onset patterns were considered localizing if they were focal sub-lobar and non-localizing if they involved multiple sub-lobar areas or brain lobes. DCS Methodology After the electrophysiological plot test, only electrically compatible with gray matter contacts were chosen for DCS. High-frequency DCS (1-5 mA, 50 Hz, 5-10 seconds) of the selected cortical contacts was performed on all patients. We also delivered low-frequency pulses (1-5 mA, 1 Hz, 20-40 seconds) to patients with mesial temporal lobe epilepsy. Both types of DCS were performed after recording spontaneous seizures (except in one patient who showed no spontaneous seizures during three-week-long intracranial exploration). Patients received their regular anti-seizure medications (ASMs) regimen during DCS, which was re-started after recording spontaneous seizures. Additionally, clinical symptoms elicited by the stimulations were recorded, and particular emphasis was given to the elicited semiologically typical auras. ADs were defined as rhythmic transient epileptic activity caused by DCS, which does not produce clinical symptoms and shows no evolution but lasts for more than 2 seconds (Gollwitzer et al., 2018). Statistical analysis A descriptive analysis of all variables of interest was carried out. For this purpose, the mean, standard deviation, and range were calculated for numeric variables, and the absolute and relative frequencies were computed in the case of categorical variables. Contingency tables were constructed by recording the spontaneous seizures and those caused by DCS. To build the contingency tables, all seizures and stimuli were classified. Triggered seizures electro-clinically identical to spontaneous seizures were considered as true positives (TP). A false positive (FP) seizure was considered when stimulation produced a seizure not electro-clinically concordant with the patient’s spontaneous seizures (Fig. 1). A true negative (TN) was recorded when the stimuli outside the spontaneous recorded SOZ did not trigger a seizure. A false negative (FN) was considered when the stimulation of contacts within the SOZ did not cause seizures. In this analysis, we performed a two-fold analysis, first using the validation measures for the entire sample 8 of patients to compare the proportions of true positives between patients with good and poor postoperative outcomes. Subsequently, we performed the analysis considering patients who had become seizure free (SF) equivalent to Engel I, compared to those who were not seizure free (NSF), including Engel II to IV, to assess the proportion of DCS outcomes. The true positive (sensitivity) and true negative (specificity) rates, as well as the positive (PPV) and negative (NPV) predictive values, have been estimated fitting mixed-effects logistic regression models. For the estimation of the TP and TN rates, the outcome variable of the model was a stimulated seizure, and the explicative variable was a spontaneous seizure. For the accuracy measure, a random-effects logistic regression model has been fitted to model seizures and stimuli concordance. In addition, the associations of the classification in seizure free or non-seizure free with several variables of interest were studied using bivariate analyses. In the case of numeric variables, the t-test was used, and the chi-squared test was applied in the case of the categorical variables. Multivariate analyses were not carried out for two reasons: i) the small sample size; ii) the included variables were recorded at different time points. After completing the evaluation, patients with localized epilepsy received treatment with RF-TC, LiTT or resective surgery as indicated. Unlike other groups, we perform RF-TC as a routine procedure in focal epilepsies even though the patient is a good candidate for surgical resection. If epilepsy relapsed after RF-TC, classic surgery was performed if indicated. Patients without localized epilepsy after SEEG diagnostic were ruled out of surgical procedures. However, in patients involving eloquent areas, RF-TC was performed after a case-by-case analysis if it was considered safe for the patient. Seizure outcomes were calculated later on for all patients who received some form of surgical procedure. The data were compared between the seizure free and the non-seizure free groups. Validity measures of the diagnostic test were finally calculated in all groups. All statistical analyses were carried out with the statistical software R, version 4.0.2. (Vienna, Austria; https://www.r-project.org) and the Python scientific library. Statistical significance was set at 0.05. 15 Conflict of interest None of the authors has potential conflicts of interest to be disclosed. The authors declare that all authors in this paper have reviewed its content and agree with its final version. Funding This work received support from the project “Clúster Emergent del Cervell Humà” (CECH) and the European Regional Development Fund under the framework of the ERFD Operative Programme for Catalonia. Author contributions Miguel Ley Nácher was responsible for data collecting, statistical analysis, medical writing, and methodology design. Nazaret Peláez contributed to data collection and manuscript reviewing. Alessandro Principe contributed with medical writing, neurophysiological and graphical contents. Klaus Langhor was responsible for the statistical analysis and methodology. Riccardo Zucca reviewed the article, corrected the edition, and analysed the methodology. Rodrigo Rocamora was responsible for the study concept, methodology design and medical writing. 16 References Bancaud J, Talairach J, Schaub J. Stereotactic functional exploration of the epilepsies of the supplementary area of the mesial surfaces of the hemispheres. Electroencephalogr Clin Neurophysiol 1962; 14:788. Bancaud J, Talairach J, Morel P, Bresson M, Bonis A, Geier S, et al. Generalized epileptic seizures elicited by electrical stimulation of the frontal lobe in man. Electroencephalogr Clin Neurophysiol 1974; 37:275-82. Bancaud J, Chauvel P. Commentary: acute and chronic intracranial recordings and stimulation with depth electrodes. In: Engel J Jr (editor). Surgical treatment of the epilepsies. New York: Raven Press. 1986; 289-96. Bank AM, Shevon CA, Hamberger MJ. Characteristics and clinical impact of stimulation-evoked seizures during extraoperative cortical mapping. Epilepsy Behav. 2014; 34:6-8. Bartolomei F, Wendling F, Régis J, Gavaret M, Guye M, Chauvel P. Pre-ictal synchronicity in limbic networks of mesial temporal lobe epilepsy. Epilepsy Res. 2004; 61:89-104. Bernier GP, Richer F, Giard N, Bouvier G, Mercier M, Turmel A, et al. Electrical stimulation of the human brain in epilepsy. Epilepsia. 1990; 31(5): 513-520. Blume WT, Jones DC, Pathak P. Properties of after-discharges from cortical electrical stimulation in focal epilepsies. Clin Neurophysiol. 2004; 115(4):982-989. Boido D, Kapetis D, Gnatkovsky V, Pastori C, Galbardi B, Sartori I, et al. Stimulus-evoked potentials contribute to map the epileptogenic zone during stereo-EEG presurgical monitoring. Hum Brain Mapp. 2014; 35(9): 4267-81. Boyer A, Duffau H, Mandonnet E, Vincent MA, Ramdani S, Guiraud D, et al. Attenuation and delay of remote potentials evoked by direct electrical stimulation during brain surgery. Brain Topogr. 2020; 33: 143-148. 17 Buser P, Bancaud J, Talairach J. Depth recordings in man in temporal lobe epilepsy. In: Brazier MAB (editor). Epilepsy. Its Phenomenon in Man. Orlando: Academic Press, 1973: 67-97. Chassoux F, Devaux B, Landré E, Turak B, Nataf F, Varlet P, et al. Stereoelectroencephalography in focal cortical dysplasia: a 3D approach to delineating the dysplastic cortex. Brain. 2000; 123: 1733-51. Chauvel P, Landré E, Trottier S, Vignel JP. Biraben A, Devaux B, et al. Electrical stimulation with intracerebral electrodes to evoke seizures. Adv Neurol. 1993; 63:115-21. Corley JA, Nazari P, Rossi VJ, Kim NC, Fogg LF, Hoeppner TJ, et al. Cortical stimulation parameters for functional mapping. Seizure. 2017; 45: 36-41. Cuello C, von Ellenrider N, Dubeau F, Eisenberg A, Gotman J, Hall J et al. Association of cortical stimulation-induced seizures with surgical outcome in patients with focal drug-resistant epilepsy. JAMA Neurol. 2019; 76(9): 1070-1078 Cushing H. A note upon the faradic stimulation of the postcentral gyrus in conscious patients. Brain. 1909; 33:44-53. David O, Wozniak A, Minotti L, Kahane P. Preictal short-term plasticity induced by intracerebral 1Hz stimulation. Neuroimage. 2008; 39(4):1633-46. David O, Bastin J, Chabardés S, Minotti L, Kahane P. Studying network mechanisms using intracranial stimulation in epileptic patients. Front Syst Neurosci. 2010; 20:4:148. David O, Job AS, De Palma L, Hoffmann D, Minotti L, Kahane P. Probabilistic functional tractography of the human cortex. Neuroimage. 2013; 80: 307-317. Desai A, Bekelis K, Thadani VM, Roberts DW, Jobst BC, Duhaime AC, et al. Interictal PET and ictal subtraction SPECT: sensitivity in the detection of seizure foci in patients with medically intractable epilepsy. Epilepsia. 2013; 54(2): 341-350. Dionisio S, Mayoglou L, Cho SM, Prime D, Flanigan PM, Lega B, et al. Connectivity of the human insula: A cortico-cortical evoked potential (CCEP) study. Cortex. 2019; 120: 419-442. 18 Foerster O, Penfield W. The structural basis of traumatic epilepsy and results of radical operation. Brain. 1930; 53:99-119. Gollwitzer S, Hopfengärtner R, Rössler K, Müller T, Olmes DG et al.. After-discharges elicited by cortical electric stimulation in humans: when do they occur and what do they mean? Epilepsy Behav. 2018; 87:173-179. Halgren E, Walter RD, Cherlow DG, Crandall PH. Mental phenomena evoked by electrical stimulation of the human hippocampal formation and amygdala. Brain. 1978; 101:83-117. Huang Y, Hajnal B, Entz L, Fabó D, Herrero JL, Mehta AD, Keller CJ. Intracortical dynamics underlying repetitive stimulation predicts changes in network connectivity. J Neurosci. 2019; 39(31):6122-6135. Jacobs J, Zijlmans M, Zelmann R, Olivier A, Hall J, Gotman J, et al. Value of electrical stimulation and high frequency oscillations (80-500 Hz) in identifying epileptogenic areas during intracranial EEG recordings. Epilepsia. 2010; 51(4): 573-582. Kahane P, Hoffman D, Minotti L, Berhoz A. Reappraisal of the human vestibular cortex by cortical electrical stimulation study. Ann Neurol. 2003; 54(5):615-24. Kahane P, Landré E, Minotti L, Francione S, Ryvlin P. The Bancaud and Talairach view on the epileptogenic zone: a working hypothesis. Epileptic Disord. 2006; 8 Suppl 2: S16-26. Kämpfer C, Racz A, Quesada CM, Elger CE, Surges R. Predictive value of electrically induced seizures for postsurgical seizure outcome. Clin Neurophysiol. 2020;131(9):2289-2297. Kovac S, Kahane P, Diehl B. Seizures induced by direct cortical stimulation – Mechanisms and clinical considerations. Clin Neurophysiol. 2016; 127: 31-39. Mariani V, Balestrini S, Gozzo F, Pelliccia V, Mai R, Francione S, et al. Intracerebral electrical stimulations of the temporal lobe: a stereo-electroencephalography study. Eur J Neurosci. 2021; 54(4): 5368-5383. 19 Niu N, Xing H, Wu M, Ma Y, Liu Y, Ba J et al. Performance of PET imaging for the localization of epileptogenic zone in patients with epilepsy: a meta-analysis. Eur Radiol. 2021; 31(8): 6353-6366 Ojemann G, Ojemann J, Lettich E, Berger M. Cortical language localization in left, dominant hemisphere. An electrical stimulation mapping investigation in 117 patients. J Neurosurg. 2008;108(2):411-21. Penfield W, Jasper O. Epilepsy and the functional anatomy of human brain. Little, Brown, Boston. Science. 1954; 119:645-646. Pizarro D, Toth E, Irannejad A, Riley KO, Jaisani Z, Muhlhofer W, et al. Auras localized to the temporal lobe disrupt verbal memory and learning - Causal evidence from direct electrical stimulation of the hippocampus. Epilepsy Behav Case Rep. 2018. 10:99-101. Rahimpour S, Haglund MM, Friedman AH, Duffau H. History of awake mapping and speech and language localization: from modules to networks. Neurosurg Focus. 2019; 47(3): E4. Rosenow F, Lüders H. Presurgical evaluation of epilepsy. Brain. 2001. 124(9): 1638-700 Sarubbo S, Tate M, De Benedictis A, Merler S, Moritz-Gasser S, Herbet G, et al. Mapping cortical hubs and white matter pathways by direct electrical stimulation: An original functional atlas of the human brain. Neuroimage. 2020; 205: 116237. Schulz R, Lüders HO, Tuxhorn I, Ebner A, Holthausen H, Hoppe M, et al. Localization of epileptic auras induced on stimulation by subdural electrodes. Epilepsia. 1997; 38(12): 1321-1329. Singh S, Sandy S, Wiebe S. Ictal onset on intracranial EEG: Do we know it when we see it? State of the evidence. Epilepsia. 2015; 56:1629-1638. Stephani C, Lüders HO. Electrical stimulation of invasive electrodes in extratemporal lobe epilepsy. In: Koubeissi MZ, Maciunas R (editors). Extratemporal lobe epilepsy surgery. Montrouge, France: John Libbey Eurotext. 2011; p.261-315. 20 Talairach J, Bancaud J. Stereotaxic Approach to Epilepsy. In: Krayenbühl H, Maspes PE, Sweet WH (editors). Progress in Neurological Surgery. Prog Neurol Surg. Basel, Karger, 1973, vol 5, pp 297- 354. Talairach J, Bancaud J, Szikla G, Bonis A, Geier S, Vedrenne C. Approche nouvelle de la neurochirurgie de l’epilepsie. Neurochirurgie 1974; 20 Suppl.1: 1-240. Trébuchon A, Chauvel P. Electrical stimulation for seizure induction and functional mapping in stereoelectroencephalography. J Clin Neurophysiol. 2016; 33:511-521. von Oertzen TJ. PET and ictal SPECT can be helpful for localizing epileptic foci. Curr Opin Neurol. 2018; 31(2):184-191. Voskuyl RA, Dingemanse J, Danhof M. Determination for the threshold for convulsions by direct cortical stimulations. Epi Res. 1989; 3(2): 120-129. Wieser HG, Bancaud J, Talairach J, Bonis A, Szikla G. Comparative value of spontaneous and chemically and electrically induced seizures in establishing the lateralization of temporal lobe seizures. Epilepsia. 1979; 20:47-59. Wyler AR, Ward AA. Neurons in human epileptic cortex. Response to direct cortical stimulation. J Neurosurg. 1981; 55(6):904-8. 21 Legends Table 1: Demographics and seizure outcome-related factors. n: sample size available for each variable. In parenthesis, the number of seizure free and non-seizure free patients is reported. p: pvalue obtained from either t-test or chi-squared test. NSF: non-seizure free + nonsurgical/radiofrequency thermo-coagulation/laser interstitial thermo-ablation candidates’ group. SD: standard deviation. TLE: temporal lobe epilepsy; FLE: frontal lobe epilepsy; IE: insular epilepsy; PLE: parietal lobe epilepsy; OLE: occipital lobe epilepsy; MRI: magnetic resonance imaging; Sz: seizures. SOZ: seizure onset zone; DCS: direct cortical stimulation; Hz: Hertz; s: seconds; RF-TC: radiofrequency thermo-coagulation; LiTT: laser interstitial thermotherapy. Table 2: Contingency table of elicited seizures and stimulations, validity measures of the diagnostic test and distribution of seizure type/stimulations in seizure free group. n: number of patients; CI: confidence interval; SD: standard deviation. PPV: positive predictive value; NPV: negative predictive value; TPS: true positive seizures; FPS: false positive seizures; TNS: true negative stimulations; FNS: false-negative stimulations. Figure 1. Example of a patient in which RF-TC targeted only the contacts involved in true positive seizures elicitation during DCS rendering a seizure free state one year after treatment. A: iEEG recording of a spontaneous seizure. Electrical pattern showing SOZ on the left amygdala. Ictal timefrequency plot of the SOZ (contact A’1-2). B: iEEG recording of a true positive seizure generated after electrical stimulation of the left amygdala (50Hz). Ictal time-frequency plot of the SOZ (contact A’1-2). C: a false positive elicited seizure. D & E: implantation strategy. F: anatomical seizure onset zone (left amygdala, targeted with electrode A’). RF-TC: radiofrequency thermocoagulation; DCS: direct cortical stimulation; iEEG: intracranial electroencephalography; SOZ: seizure onset zone; s: seconds; Hz: Hertz; dB/Hz: decibels vs Hertz. A’-C’: contact position in the brain. Figure 2. Comparison between the seizure free (SF) and non-seizure free candidates (NSF/NC) groups in relation to the targets obtained with the radiofrequency thermocoagulation (RF-TC) and the resection on the spontaneous seizure onset zone (SOZ) and that obtained by direct cortical stimulation (DCS). (RF-TC vs Spontaneous SOZ: percentage of contacts involved in the 22 spontaneous SOZ that were targeted with RF-TC; RF-TC vs DCS-SOZ: percentage of contacts involved in TP seizures obtained during DCS that were targeted with RF-TC; Resection vs Spontaneous SOZ: percentage of contacts of the spontaneous SOZ that were resected with surgery; Resection vs DCS-SOZ: percentage of contacts involved in TP seizures obtained during DCS that were resected with surgery). % percentage; p = p-value; TP: true positive seizures. 23 n Seizure free Non-seizure free p-value Age (years) 58 (27/31) 35.3 (SD 11.5 [19-59]) 36.3 (SD 10.5 [15-53]) 0.733 Gender (Female) 58 (27/31) 10 (37.0%) 12 (38.7%) 0.896 Type of epilepsy TLE FLE IE PLE OLE 58 (27/31) 20 (74.1%) 3 (11.1%) 0 2 (7.4%) 2 (7.4%) 13 (41.9%) 4 (12.9%) 4 (12.9%) 6 (19.4%) 4 (12.9%) 0.090 MRI Lesion 58 (27/31) 9 (33.3%) 17 (54.8%) 0.100 Epilepsy onset (years) 58 (27/31) 15.1 (SD 10.1 [1-48]) 14.4 (SD 7.4 [1-30]) 0.777 Epilepsy duration (years) 58 (27/31) 20.3 (SD 11.9 [5-44]) 21.9(SD 12.9 [3-50]) 0.617 Localizing spontaneous Sz Pattern 58 (27/31) 21 (77.8%) 15 (48.4%) 0.021 DCS typical Sz onset pattern 39 (21/18) 14 (66.7%) 12 (66.7%) 0.459 Number of spontaneous Sz 58 (27/31) 15.0 (SD 21.3 [0-94]) 130.5 (SD 423.2 [2-2386) 0.162 Number of 1Hz DCS Sz 34 (17/17) 0.35 (SD 0.6 [0-2]) 0.06 (SD 0.2 [0-1]) 0.073 Number of 50Hz DCS Sz 58 (27/31) 4.1 (SD 3.5 [0-11]) 1.8 (SD 1.9 [0-6]) 0.003 Number of DCS contacts 57 (27/30) 73.3 (SD 29.0 [21-129]) 73.0 (SD 35.9 [11-171]) 0.976 Number of implanted electrodes 58 (27/31) 11.2 (SD 3.1 [5-15]) 12.3 (SD 3.7 [6-19]) 0.242 Total seizures triggered 58 (27/31) 4.3 (SD 3.5 [0-11]) 1.8 (SD 1.9 [0-6]) 0.001 Patients with after-discharges 58 (27/31) 26 (96.3%) 26 (83.9%) 0.264 Patients with interictal rhythmic spikes 58 (27/31) 7 (25.9%) 12 (38.7%) 0.301 Number of contacts involved in 3 s 57 (26/31) 7.2 (SD 6.5 [1-27]) 12.5 (SD 14.6 [2-68]) 0.093 DCS elicited Sz -spontaneous SOZ agreement (in %) 57 (26/31) 26.0 (SD 28.8 [0-100]) 7.6 (SD 16.8 [0-66]) 0.004 Number of typical auras elicited 58 (27/31) 3.6 (SD 4.8 [0-18]) 1.6 (SD 2.7 [0-10]) 0.048 Patients with subclinical DCS Sz concordant with SOZ 58 (27/31) 3 (11.1%) 6 (19.4%) 0.387 Number of DCS elicited Sz non-concordant with spontaneous SOZ 58 (27/31) 2.0 (SD 2.6 [0-10]) 1.2 (SD 1.7 [0-6]) 0.139 Patients treated with RF-TC 58 (27/31) 16 (59.3%) 21 (67.7%) 0.503 Patients treated with resection 58 (27/31) 15 (55.6%) 13 (41.9%) 0.300 Patients treated with RF-TC + resection 58 (27/31) 7 (25.9%) 7 (22.6%) 0.766 RF-TC & Spontaneous SOZ agreement (in %) 39 (15/24) 55.0 (SD 27.9 [10-100]) 28.6 (SD 25.7 [0-100]) 0.005 RF-TC & DCS-SOZ agreement 25 (12/13) 55.6 (SD 37.2 [0-100]) 46.8 (SD 42.4 [0-100]) 0.587 Resection & Spontaneous SOZ agreement (in %) 24 (15/9) 89.1 (SD 20.0 [43-100]) 56.8 (SD 42.6 [0-100]) 0.019 24 Seizure elicited Electro-clinically identical seizure Yes No Yes True positive (59) False-positive (57) No False-negative (198) True negative (1784) Seizure free n 27 Sensitivity 23.0%; CI (95%): [18.2-28.5] Specificity 96.9%; CI (95%): [96.0-97.6] PPV 50.9%; CI (95%): [41.9-59.8] NPV 90.0%; CI (95%): [88.6-91.3] Accuracy 87.9%; CI (95%): [86.4-89.2] n Mean SD Rank TPS 27 2.2 2.4 0-9 FPS 27 2.1 2.7 0-10 TNS 27 66.1 30.7 18-134 FNS 27 7.3 10.7 0-51 Resection & DCS SOZ agreement (in %) 23 (13/10) 89.4 (SD 26.9 [12.5-100]) 23.3 (SD 41.7 [0-100]) <0.001 LiTT 58 (27/31) 0 2 (6.5%) 0.534