Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings

Karatsiompani, Maria Christina

Abstract

El sector de la construcció té un gran potencial per reduir les emissions de gasos amb efecte d'hivernacle. Per aconseguir la seva descarbonització necessària es requereixen estudis detallats de les seves característiques i el seu comportament energètic a diferents escales. A Espanya, les estratègies nacionals de renovació energètica utilitzen enfocaments arquetípics per avaluar el consum energètic i prioritzar les intervencions. Models similars es fan servir a nivell de districte, però la seva precisió a aquesta escala és incerta. L'objectiu principal d'aquest projecte és aplicar els mètodes de diagnòstic energètic dissenyats per a una escala nacional, a nivell de districte intermedi i avaluar fins a quin punt s'alineen amb la realitat del parc immobiliari a aquesta escala. Per aconseguir-ho, s'ha desenvolupat una metodologia per comparar els valors U dels arquetips d'edificis residencials, tal com es defineixen als models nacionals, amb els valors U calculats a partir de dades a nivell d'habitatge, segons la base de dades de certificats eficiència energètica (EPC). El cas d’estudi per validar aquesta hipòtesi és la costa occidental del riu Besòs a Barcelona. Es realitza una anàlisi comparativa mitjançant la representació gràfica dels resultats, utilitzant eines tant estadístiques com georeferenciades. Finalment, també es fa una clusterització dels valors U del cas d'estudi per identificar possibles patrons. Els resultats van revelar diferències significatives entre els valors U predits pels models nacionals i els obtinguts dels EPC. Alhora, no es va trobar una relació directa entre els clústers produïts i les variables de segmentació utilitzades en els models nacionals. Els resultats confirmen que els criteris de segmentació proposats no expliquen completament la variabilitat del parc immobiliari a nivell de districte.

Full text

Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings Master Tesis September 2023 Maria Karatsiompani Tutors: Mariana Palumbo Fernandez, Olga Alcaraz Sendra Co-tutor: Pablo Buenestado Caballero Double Master’s degree: MCTS – Sustainability Science and Technology MISMeC – Sustainable Intervention in the Built Environment UPC - Polytechnic University of Catalonia IS.UPC - University Research Institute for Sustainability Science and Technology Acknowledgements This master thesis would never have been possible without my tutors, Mariana, Olga, and Pablo that guided me with their kind personalities, showing patience, dedication, and extraordinary knowledge. Furthermore, I would like to express my gratitude to all the professors of this double master’s degree that created this incredible academic program, sharing their vision on Sustainability. To my classmates from both masters that made this experience unique, entertaining, and inspirational. Also, to all the research team of MAREnE project, Ana, Pau, Alfonso, and Patricia, for making me feel part of the team, and their interest and valuable comments on my master thesis. To my family, that are the most caring and supportive people I could wish for. To my chosen family, my friends that live close-by or far away, but always feel like a huge hug wherever I am. To Ricard and Mia, for the unconditional support. Abstract The building sector currently has the greatest potential to reduce greenhouse gas emissions. To achieve its necessary decarbonization, in-depth studies of its characteristics and its energy behavior across different scales are necessary. In Spain, national energy retrofitting strategies follow experience-based archetype approaches to assess energy use and prioritize interventions. Similar models are used at the district level, but their accuracy at this scale is unclear. The main goal of this final project arises: to test national-scale energy diagnosis methods on an intermediate district level and assess to what extend they align with the reality of the building stock at this intermediate scale. To accomplish this, a methodology has been developed to compare the U-values of residential building archetypes, as defined in the national models, with the U-values calculated from data at the dwelling level, according to the energy performance certificate database (EPC). The case study to validate this hypothesis is the western coast of Besòs river in Barcelona. A comparison analysis is conducted through graphical representation of the results, using both statistical and georeferenced tools. Finally, a clustering classification of the case study U-values is also conducted, to group the building stock according to its U-values and explore potential patterns. The results revealed significant differences between the predicted U-values from national models and those from EPC data. At the same time, no straightforward relationship was found between the produced clusters in the case study and the segmenting variables utilized in national models. The results validate the initial hypothesis that the proposed segmentation criteria don’t fully explain the variability of the building stock at the district level. Resumen El sector de la construcción tiene un gran potencial para reducir las emisiones de gases de efecto invernadero. Para lograr su necesaria descarbonización se requieren estudios detallados de sus características y su comportamiento energético a diferentes escalas. En España, las estrategias nacionales de renovación energética utilizan enfoques arquetípicos para evaluar el consumo energético y priorizar las intervenciones. Modelos similares se emplean a nivel de distrito, pero su precisión a esta escala es incierta. El objetivo principal de este proyecto es aplicar los métodos de diagnóstico energético diseñados para una escala nacional, a nivel de distrito y evaluar en qué medida se alinean con la realidad del parque inmobiliario a esta escala. Para lograrlo, se ha desarrollado una metodología para comparar los valores U de los arquetipos de edificios residenciales, tal como se definen en los modelos nacionales, con los valores U calculados a partir de datos a nivel de vivienda, según la base de datos de certificados de eficiencia energética (EPC). El caso de estudio para validar esta hipótesis es la costa occidental del río Besòs en Barcelona. Se realiza un análisis comparativo mediante la representación gráfica de los resultados, utilizando herramientas tanto estadísticas como georreferenciadas. Finalmente, también se realiza una clusterización de los valores U del caso de estudio, para identificar posibles patrones. Los resultados revelaron diferencias significativas entre los valores U predichos por los modelos nacionales y los obtenidos de los EPC. Al mismo tiempo, no se encontró una relación directa entre los clústeres producidos y las variables de segmentación utilizadas en los modelos nacionales. Los resultados confirman que los criterios de segmentación propuestos no explican completamente la variabilidad del parque inmobiliario a nivel de distrito. Resum El sector de la construcció té un gran potencial per reduir les emissions de gasos amb efecte d'hivernacle. Per aconseguir la seva descarbonització necessària es requereixen estudis detallats de les seves característiques i el seu comportament energètic a diferents escales. A Espanya, les estratègies nacionals de renovació energètica utilitzen enfocaments arquetípics per avaluar el consum energètic i prioritzar les intervencions. Models similars es fan servir a nivell de districte, però la seva precisió a aquesta escala és incerta. L'objectiu principal d'aquest projecte és aplicar els mètodes de diagnòstic energètic dissenyats per a una escala nacional, a nivell de districte intermedi i avaluar fins a quin punt s'alineen amb la realitat del parc immobiliari a aquesta escala. Per aconseguir-ho, s'ha desenvolupat una metodologia per comparar els valors U dels arquetips d'edificis residencials, tal com es defineixen als models nacionals, amb els valors U calculats a partir de dades a nivell d'habitatge, segons la base de dades de certificats eficiència energètica (EPC). El cas d’estudi per validar aquesta hipòtesi és la costa occidental del riu Besòs a Barcelona. Es realitza una anàlisi comparativa mitjançant la representació gràfica dels resultats, utilitzant eines tant estadístiques com georeferenciades. Finalment, també es fa una clusterització dels valors U del cas d'estudi per identificar possibles patrons. Els resultats van revelar diferències significatives entre els valors U predits pels models nacionals i els obtinguts dels EPC. Alhora, no es va trobar una relació directa entre els clústers produïts i les variables de segmentació utilitzades en els models nacionals. Els resultats confirmen que els criteris de segmentació proposats no expliquen completament la variabilitat del parc immobiliari a nivell de districte. I Table of Contents List of Figures ...................................................................................................................................... III List of Tables ........................................................................................................................................ V List of Cartography ............................................................................................................................ VI List of Equations ................................................................................................................................ VI Abbreviations .................................................................................................................................... VII Glossary ............................................................................................................................................. VII 1. Introduction ..................................................................................................................................1 1.1. Motivation .............................................................................................................................. 1 1.2. Hypothesis and goals ........................................................................................................... 3 1.3. Structure ................................................................................................................................ 4 2. State of the art ..............................................................................................................................6 2.1. Contribution of the building sector to the European emissions ..................................... 6 2.2. The European buildings energy performance and policy ............................................... 6 2.3. Estimation of the energy use of the building sector: methodologies ............................ 8 2.3.1. Overview of the top-down models ............................................................................. 9 2.3.2. Overview of the bottom-up models ........................................................................ 10 2.4. Building stock energy models in Spain ........................................................................... 12 2.5. Variables that affect buildings energy demand ............................................................. 13 2.6 Uncertainty ...........................................................................................................................15 3. Methodology ............................................................................................................................. 18 3.1. National building stock models analysis ......................................................................... 19 3.2. Territorial scope extension ............................................................................................... 20 3.3. Data preparation ................................................................................................................ 21 3.2.1 Data collection ................................................................................................................. 21 3.2.2 Database creation ...................................................................................................... 23 3.2.3 Database preprocessing ........................................................................................... 26 3.4. Data segmentation according to GTR and ERESEE criteria .......................................... 27 3.5. Clustering classification .................................................................................................... 29 3.5.1. Clustering variables and data normalization .......................................................... 30 3.5.2. Number of clusters .................................................................................................... 31 3.5.3. Algorithm application ................................................................................................ 31 3.5.4. Result assessment ...................................................................................................... 31 3.6. Results mapping ................................................................................................................ 32 II 4. Selected methodologies on Spanish national level ................................................................ 33 4.1. The World Wildlife Fund for Nature (WWF) energy efficiency Report......................... 33 4.2. The Working Group on Rehabilitation (GTR) set of reports .......................................... 37 4.3. The long-term Strategy for energy renovation of the building sector in Spain (ERESEE) 42 5. Descriptive analysis of the case study ................................................................................... 45 6. Results ........................................................................................................................................ 52 6.1. Creation of the GTR segments in the territorial context ................................................ 52 6.2. GTR - U Values overview ................................................................................................... 54 6.3. GTR deviation assessment ................................................................................................ 58 6.4. Creation of the ERESEE segments in the territorial context ......................................... 60 6.5. ERESEE - U Values overview ............................................................................................. 61 6.6. ERESEE deviation assessment .......................................................................................... 67 6.7. K-means Clustering ........................................................................................................... 68 7. Conclusions and future work ................................................................................................... 75 References ......................................................................................................................................... 78 Annex 1: Results per GTR segment ................................................................................................ 82 Annex 2: Results per ERESEE segment ......................................................................................... 91 III List of Figures Figure 1 Limiting warming to 1.5 oC and 2oC involves rapid, deep and in most cases immediate greenhouse gas emission reductions. Source: (Calvin et al., 2023) ............................................... 1 Figure 2 Building sector in the EU energy consumption (left) and energy related GHG emissions. ............................................................................................................................................. 6 Figure 3 Share of EU buildings built before thermal regulations and thus considered energy inefficient (left) and annual renovation rates (right) in the EU building stock. .............................. 7 Figure 4 Residential energy consumption modeling techniques. (Swan & Ugursal, 2009) ........ 9 Figure 5 Methodology overview .................................................................................................... 18 Figure 6 Graphical overview of the database creation process .................................................. 23 Figure 7 Example of Inspire layer polygons on the left and CONSTRU layer polygons on the right. ................................................................................................................................................... 24 Figure 8 Cadastral reference explanation per digits .................................................................... 24 Figure 9 Dependance between the segmentation variables and the variables used for energy demand calculation (WWF). ............................................................................................................ 35 Figure 10 Overview of the WWF methodology. ........................................................................... 36 Figure 11 Dependance between the segmentation variables and the variables used for energy demand calculation (GTR) ................................................................................................................ 40 Figure 12 Dependance between the segmentation variables and the variables used for energy demand calculation (ERESEE) ......................................................................................................... 44 Figure 13 Buildings´ typology pie chart (left) and year of construction pie chart (right) .......... 45 Figure 14 Number of floors pie chart grouped into more than 3 floors and less or equal to 3 floors (right) and barplot of the exact number of floors of the building stock (right). .............. 46 Figure 15 Surface boxplot (left) and histogram (right), for housing dwellings. ......................... 47 Figure 16 Surface boxplot (left) and histogram (right), for housing blocks. .............................. 47 Figure 17 Qualification of CO2, with highlighted the building labels that need to be renovated by 2033 (upper left), qualification of primary non-renewable energy consumption (upper right) and qualification of heating energy demand (down) pie charts in the case study. .................. 48 Figure 18 Non-renewable primary energy consumption boxplot (left) and histogram (right). 49 Figure 19 Heating energy demand boxplot (left) and histogram (right). .................................. 50 Figure 20 Average façade U-vales boxplot (left) and histogram (right) ..................................... 50 Figure 21 Average openings´ U-vales boxplot (left) and histogram (right) ................................ 51 Figure 22 GTR segments in the case study pie chart .................................................................... 53 Figure 23 Relation between façade (x axis) and openings (y axis) U-value per GTR segments55 Figure 24 Relation between the U values, divided per GTR segment on each graph. Red points are the determined from GTR methodology values. .................................................................... 55 Figure 25 Façade U-values overview boxplot per GTR segment. With red lines, the determined from GTR methodology values. ....................................................................................................... 56 Figure 26 Openings´ U-values overview boxplot per GTR segment. With red lines, the determined from GTR methodology values. ................................................................................. 57 Figure 27 Facade U value histogram of segment H ...................................................................... 58 Figure 28 Openings U value histogram of segment H ................................................................. 58 Figure 29 ERESEE segments in the case study pie chart .............................................................. 61 Figure 30 Relation between façade (x axis) and openings (y axis) U-value per ERESEE segments ............................................................................................................................................................. 62 Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 2 The building sector has significant environmental impacts. It contributes to 21% of global greenhouse gas emissions and 31% of global final energy demand in 2019. If only CO2 emissions would be considered, the share of CO2 emissions from buildings out of global CO2 emissions increases to 31% (Cabeza et al., 2023). At the same time, studies performed by the IPCC demonstrate a mitigation potential of the building sector of up to 85% in Europe and North America. In the European context, the building sector is the biggest energy consumer. The low renovation rates, and ambition level when existing buildings are renovated, is considered one of the main drivers of emissions both in the present and in the future projections. To reduce this impact in the building sector and meet EU greenhouse gas reduction goals, energy renovation of the existing building stock is considered strategic. In order to guarantee that these renovations will be successful in terms of energy and resource efficiency, it is necessary to study which interventions enable long term and meaningful improvements. This calls for in-depth studies of current and future energy use of building stock, that allow an accurate assessment of the potential of improvements to be implemented. Those studies are important to be undergone in different scales, at building level, at aggregate urban scale level or even at national level, allowing a deep understanding of the building stock. In Spain, methodologies for the energy retrofit of Spain’s national housing stock are developed in the last decade. These methodologies study the current energy use in buildings and make intervention proposals, assessing the resulting savings in energy and emissions. To calculate the energy use in buildings, they follow an experience-based, or else-said, deterministic, archetype approach. This means that they divide the building stock into groups of similar buildings according to qualitative variables (segmentation). Then, they assign geometrical and thermal properties (characterization), creating archetypes of buildings that are considered to be exemplary, representing each group. The energy demand is calculated for each group´s archetype, scaling up by multiplying the results by the number of houses of each archetype. This approach is useful on a national scale; however, it has been criticized for oversimplifying the diversity of the building stock, particularly when applied on a smaller scale (Reinhart & Cerezo Davila, 2016). District-level building stocks often represent unique variability that can be easily overseen when examined at the national scale but becomes very straightforward when diagnosed in detail at the district scale. They are formed by a variety of buildings constructed during different periods of time and inhibited by users of different socio-economic backgrounds. They are modified according to their user´s special needs, that are further dictated by political conditions, social movements and economic transformations that were conducted during their lifespan. Such transformations are changes of their interior distributions, construction of extensions such as addition of volumes, balconies etc, alteration of the openings size, form, or materials, changes in the thermal and electrical installations etc. District level energy diagnoses are currently of great importance, since neighborhood regeneration projects appear more often in the agendas of local town halls, for a number of reasons. Apart from contributing to the broader national and global sustainability goals, they have direct benefits for the quality of life and well-being of the residents, they address local issues and provide tailored solutions, as well as including participatory processes of the community. Local governments are often better equipped to provide important changes in the district, because of established synergies with other local actors. To incorporate energy Maria Karatsiompani MCTS | MISMEC 3 performance improvements in these projects, a detailed diagnosis of the district building stock is required. Yet local town halls in Spain don’t have some established framework to perform this energy diagnosis at the district level. Another reason why building stock energy models at the district level are gaining importance is the incorporation of renewable energy sources systems. The shift towards renewable energy sources systems has created an increasing interest in the storage and demand response mechanisms to maintain a stable and reliable electricity grid. Moreover, concepts like energy sovereignty and the role of community are introduced in the energy debate (Sorman et al., 2020). Questions such as where the energy comes from, who is in control of it and who consumes it, are arising. Consequently, the need to design energy systems at a district level increases, as opposed to the more traditional approaches focusing on the individual building level. 1.2. Hypothesis and goals Cartography 1 Case study area The basic hypothesis of this master thesis is that national level methodologies are not applicable at neighborhood level. Since there is currently no established framework in Spain to assess the energy use of the building stock at district level, available for the local town halls it is considered very important for this study to assess the gap between national-level building stock models and the unique complexities of district-level building stocks. By understanding this gap, local decision-makers can be empowered by the information needed to develop Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 4 targeted and well-adapted urban energy renovation programs, that respond to the real deficiencies of the buildings in question and improve the lives of their residents. The basic goal of this research is to evaluate the reliability of national archetype approaches at a district level, focusing on the thermal transmittance (U-value) of facades and openings in residential buildings, through a case study. Thermal transmittances are usually uncertain to determine, while they influence the thermal balance of buildings and consequently, their energy demand. To reach this goal, a methodology has been developed that compares the façade and openings thermal transmittance of the building stock segments, as defined in the methodologies at a national scale with the U-values as calculated from data at the dwelling scale. The case study area is the western coast of Besòs River, inside the limits of Barcelona city, as seen in cartography 1. It is formed by neighborhoods that primarily are in the process of urban renewal, while at the same time they are some of the most vulnerable of the city. This research aims to examine the case study at the dwelling level, generating precise information about the energy performance and efficiency of buildings in that area. This context-specific knowledge is vital for customizing energy retrofitting and efficiency strategies to meet the district's unique needs. Moreover, the present study forms part of a bigger investigation project, called “New methodology to support the energy refurbishment of buildings. Incorporation of sensitivity and uncertainty analysis in the definition of the building stock (MAREnE)”. This project aims to tackle the uncertainty in the characterization of the building stock and this thesis seeks to contribute its findings to the investigation project. 1.3. Structure The present study is divided into seven chapters, each serving a distinct purpose within this research. The first chapter corresponds to the introduction, where the basic interest of this work is explained, by briefly presenting the existing framework, the literature gaps as well as the specific goals to be reached by this study. The second chapter contextualizes the study by providing essential background information. It elucidates the current European energy performance policy, introduces the foundational methodologies for analyzing building energy performance as well as the corresponding methodologies currently developed to date on the Spanish national level, and it outlines the variables relevant to energy demand calculations for the building stock. Finally, the uncertainty in these methodologies is discussed. The third chapter explains the methodology that is used to segment the case study according to the current national Spanish strategies selected, as well as to assess the results of the reliability of those methodologies. In the fourth chapter, the selected national methodologies are further analyzed, comparing the different steps that are applied to segment, characterize the building stock and finally calculate its energy consumption. The fifth chapter provides a descriptive analysis of the case study, according to the energy performance certificates database. The basic variables found in the database are statistically Maria Karatsiompani MCTS | MISMEC 5 analyzed and compared to the current construction legislation. It provides information about the characteristics of the case study building stock, as well as its energy performance. The results are presented in the sixth chapter, organized according to the applied methodologies. This chapter contains a diversity of information, ranging from graphical, numerical and cartographic information. Finally, the seventh chapter collects the main conclusions made by the present study and indicates the future work lines that could be developed in future studies. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 6 2. State of the art 2.1. Contribution of the building sector to the European emissions In the European context, buildings consume a significant amount of energy, approximately 40% of total EU´s energy consumption and 36% of the energy-related greenhouse gas emissions. This makes the building sector the largest energy consumer in Europe. Within the building sector, the major energy consuming activities are heating, cooling and domestic hot water, accounting for 80% of the energy consumed in European households. Figure 2 Building sector in the EU energy consumption (left) and energy related GHG emissions. The European Commission, as proposed in its Climate Target Plan 2030 (European Commission, 2020b), is committed to cut greenhouse gas emissions by at least 55% by 2030, compared to 1990. Since the building sector is the biggest consumer in the European Union, energy efficiency in buildings is an essential component for action and a field where efforts must be intensified. For this reason, the EU has set the goal to reduce buildings greenhouse gas emissions by 60%, their final energy consumption by 14% and energy consumption of heating and cooling specifically by 18%, compared to 2015 levels (European Commission, 2020b). To achieve these reductions, it is considered urgent by the EU to focus on buildings energy efficiency and carbon neutrality over their full life cycle. 2.2. The European buildings energy performance and policy It is quite concerning, according to the European Commission, that almost 75% of the buildings are energy inefficient. Building codes with specific regulation on thermal insulation of the building envelope started appearing after the 1970s in Europe. This means that a large share of today's EU building stock was built without any energy performance requirement: one third (35%) of the EU building stock is over 50 years old; more than 40% of the building stock was built before 1960. 40% 36% Maria Karatsiompani MCTS | MISMEC 7 Figure 3 Share of EU buildings built before thermal regulations and thus considered energy inefficient (left) and annual renovation rates (right) in the EU building stock. At the same time, only about 1% of the total European building stock undergoes energy renovation annually (European Commission, 2020a). While a total of 11% of the housing stock undergoes some form of renovation each year, energy performance improvements are rarely integrated into these renovation works. As a result, the overall weighted annual energy renovation rate remains very low at 1%, while in some regions energy renovation rates are virtually absent. This indicates a significant gap in addressing energy efficiency in the renovation of existing buildings across Europe. The European Union current policy highlights the necessity of renovating the existing building stock in the European Union (EU) to achieve energy efficiency and decarbonization goals. The first Directive of energy performance of Buildings (DEEE) was approved in 2002 (2002/91/CE). The Directive 2010/31/EU (Directive 2010/31/EU on the Energy Performance of Buildings, 2010), amended in 2018, aims to ensure that all member states have highly energy-efficient and decarbonized buildings by 2050. It introduces mandatory long-term renovation strategies for both public and private buildings, transforming them into energy-efficient and decarbonized properties by 2050. The directive also promotes the transformation of existing buildings into nearly zero-energy buildings by 2050 and mandates that all new buildings meet this standard from 2021 onwards. In December 2021, the Commission proposed a revision of the directive to align with the EU's emission reduction of 55% and climate neutrality goals by 2050. The revised directive incorporates a vision and tools to achieve a zero-emission building stock by 2050, including a new definition of zero-emission buildings and refined definitions for nearly zero-energy buildings and deep renovation. It replaces long-term renovation strategies with better monitored national building renovation plans, while increasing energy standards in new and existing buildings. In the case of existing buildings, both residential and non-residential, deadlines are set to be upgraded to a minimum energy efficiency class by 2030 and 2033. In order to achieve these goals, the "Renovation Wave" (European Commission, 2020a) initiative was launched in October 2020. It aims to at least double renovation rates over the next decade and prioritize building renovations according to greater energy and resource efficiency. This initiative builds on measures agreed upon in the "Clean Energy for All Europeans" package, including the obligation for EU countries to present their long-term building renovation strategies and relevant building aspects in their integrated national energy and climate plans. 75% 1% Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 8 2.3. Estimation of the energy use of the building sector: methodologies The current building stock, especially in Europe, is large, heterogeneous (European Commission, 2020a) and, as previously mentioned, composed of buildings with poor energy characteristics (Ballarini et al., 2014). According to the European Commission, more than 85% of the existing building stock was built before 2001 and will be standing in 2050. In order to improve energy consumption of the sector, energy renovation is considered strategic. It is extremely important to comprehend how the building stock behaves in terms of energy usage to establish goals, policies and incentives that ensure long-term energy and GHG emissions reduction. Energy renovation requires a substantial financial investment, typically sourced from the public sector, which provides funding to the private sector. Apart from the big economic investment, another critical aspect of energy renovation is the time scale of implementation. Energy renovations occur infrequently, often spanning 50 to 100 years, greatly influencing the share of the total energy usage that the building sector consumes over this extended time scope. Given the urgency of addressing global temperature rise in the coming decade, the energy renovations undertaken in the next few years will significantly impact the share of GHG emissions attributed to the building sector. Therefore, a comprehensive diagnosis and understanding of the building sector, along with its present and future energy consumption, are vital. Consequently, extensive studies employing various models are underway to ensure maximum precision in these assessments. Building energy consumption, especially in the residential sector can be challenging to comprehend and predict. This is due to a variety of factors such as the occupant behavior, the great variety of geometries and thermal properties of the envelope that the building sector encompasses, the privacy issues that limit access to real data (Swan & Ugursal, 2009) etc. Energy consumption modeling of the building stock aims to calculate the amount of energy consumed, based on various input parameters. These models are useful for multiple reasons with the primary ones being the assessment of energy demands on a regional or national scale (macro-scale) and the estimation of changes in energy usage for specific buildings following technological upgrades (micro-scale). The results are valuable in guiding policy decisions concerning both existing and new residential building structures. By quantifying energy consumption and predicting the effects of retrofits, new materials, and technology, these models inform decisions on energy supply, incentives for retrofitting and adopting new technology, development of updated building codes, and even decisions on demolishing and refurbishment of buildings. Current literature divides the modelling techniques into two basic categories: bottom-up and top-down modelling. The terms refer to the hierarchical relationship of the input data and the building stock. Top-down models use the overall sector-level data to estimate energy consumption. Bottom-up models start from individual or grouped buildings and extrapolate the energy consumption to represent larger regions. Consequently, top-down models are based on aggregated and statistical data while bottom-up models are based on building physics, that are applied on subsets or individual buildings of a building stock (Naber et al., 2017). An overview of the different energy consumption modeling techniques is presented in Figure 4. Maria Karatsiompani MCTS | MISMEC 9 Figure 4 Residential energy consumption modeling techniques. (Swan & Ugursal, 2009) 2.3.1. Overview of the top-down models The top-down approach operates at an aggregated level to study the energy consumption patterns in the building sector and understand its relationship with ongoing long-term changes or transitions of the broader economy, primarily focusing on determining energy supply needs. Some of the variables commonly used by top-down models include macroeconomic indicators like gross domestic product (GDP), employment rates, and price indices. Climatic conditions, housing construction and demolition rates, as well as estimates of appliance ownership and the number of housing units, are also considered in these models. They are further divided, according to (Swan & Ugursal, 2009), into econometric and technological top-down models. Econometric models are primarily based on the connection between the energy sector and the economic output, relating energy use and various variables, such as income, fuel prices and gross domestic product. They don’t include details related to current and future technological options, since they don’t assess the physical factors in buildings that influence energy demand, placing emphasis on macroeconomic trends and relationships observed in the past. Since they rely on past energy-economy relationships and they don’t have the capability to model discontinuous changes in technology, these types of models might not be adequate when dealing with climate change issues, where integrated and previously unexperienced changes are expected in environmental, social, and economic conditions (Kavgic et al., 2010). On the contrary, technological top-down models attribute energy consumption to characteristics of the buildings stock, such as appliance ownership trends, including a series of factors such as technological progress and structural change. Overall, top-down models have some considerable strengths and limitations. They require aggregate data which is widely available, their approach is simple to implement, and they rely on historical residential sector energy values, which adds certain stability to the model, making it well-suited to handle gradual changes. Nevertheless, they lack inherent capability to handle discontinuous advancements in technology like rapid paradigm shifts such as electrification or energy shocks. Additionally, the lack of detail regarding the energy consumption per end-use makes it impossible to identify the most problematic areas and subsequently the key aspects for potential improvement in energy efficiency. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 10 2.3.2. Overview of the bottom-up models The bottom-up modeling involves using input data at a disaggregated level within the sector. These data can include, depending on the model, individual end-uses consumption, the energy consumption of individual buildings, or groups of buildings, or energy consumption of each consumer device that makes up the individual building. These models calculate the energy consumption for these smaller units and then scale up the results to represent larger areas, like a region or a whole nation, based on how representative the sample data is. This way, they provide a more detailed understanding of the final energy consumption. Input data of bottom-up models can be very different, according to the type and the goal of the model. Common inputs can be dwelling geometry, envelope properties, equipment and appliances, climate data, indoor temperatures, occupancy schedules and equipment use. Bottom-up models operate at a disaggregated level; thus, they need extensive databases to support the detailed description of each small unit or component. The bottom-up models can use a variety of different data inputs, which results in a big variety of subdivisions of this approach. According to data input and structure, they are divided into two basic categories: statistical and engineering models. -Statistical models: Statistical models use a sample of buildings, where the energy consumption is already known. These models aim to uncover relationships between energy consumption and specific enduses, meaning activities within buildings, such as heating, cooling, lighting, and appliance usage. These relationships are created by statistical techniques such as statistical regressions. Once these relationships are established, energy consumption can be obtained as a function of building characteristics. To construct statistical models, data on energy consumption is essential. Typically, these models rely on information from consumer energy bills. However, it's worth noting that statistical models have some limitations. They do not provide much detail and flexibility and therefore have restricted capacity to evaluate the impact of a wide range of energy refurbishment scenarios (Alan Shek-Lun Fung, 2003). -Engineering models: Engineering models, or also found in literature as buildings physics-based modelling techniques, account for the energy consumption of end-uses (specific purposes or activities for which energy is consumed), based on thermodynamic relationships, heat transfer, use of equipment and systems etc. They operate based on the physical characteristics of the building stock, so they can incorporate new technologies into the models. Since the level of detail is high, they can accurately determine the energy consumption of each end-use, helping to identify areas for potential improvements. The combination of building physics and empirical data from housing surveys enables modelers to estimate past, present, and future building energy consumption, without any historical data. In Europe, policymakers find bottom-up building physics stock models valuable tools, as they provide estimates for policy effectiveness and identify measures to improve end-use efficiencies (Kavgic et al., 2010). The basic bottom-up engineering techniques are distributions, archetype, and sample. Distributions is an engineering model that uses statistical distribution of appliance ownership, usage patterns and energy ratings for those appliances to calculate the energy consumption Maria Karatsiompani MCTS | MISMEC 11 per end-use. This technique takes into account how many buildings own particular appliances, how frequently they use them and how energy efficient these appliances are. The final energy consumption is the aggregation of the energy consumptions of all appliances, to the scope of interest (regional, national, etc). Sample refers to the technique that uses actual sample building consumption data to estimate energy consumption of a wide variety of buildings within the building stock. The global energy consumption is then estimated by applying weights to the results, if the sample is sufficiently representative. Since the archetype technique is widely developed in recent years in the energy consumption estimation of the building stock, and the most relevant for this study, it is going to be briefly analyzed. The archetype technique is based in the representation of the building stock through archetypes, that are considered to represent most of the types of buildings within the building stock. Archetype is the most usual term, but it can also be found as reference buildings, representative buildings or building typologies (Borges et al., 2022). This technique is typically developed in two stages: segmentation and parameters definition (Johari et al., 2020). In the segmentation stage, the existing building stock is subdivided into segments of buildings, which are expected to have similar energy-related behavior. This segmentation is based on known qualitative variables that describe these buildings. Each class or subgroup is then represented by an archetype, that is defined in a way that best captures the key energy-related characteristics of buildings in the specific group. This step, often referred to as parameter definition, characterization, or classification in current literature, involves inferring unknown variables for the entire building stock based on the archetype's characteristics. These definitions are used as input data for energy modeling. The energy consumption is calculated for each of these representative buildings, and the results are extrapolated to the entire building stock, according to the number of buildings in each group. In this way, the computation time and complexity are reduced significantly, while still providing insights of the energy behavior of the entire building stock (Ghiassi & Mahdavi, 2017). The archetype technique essentially divides the building stock according to known variables and leverages this division to estimate other, previously unknown variables, such as the thermal properties of buildings. These newly inferred variables then become essential inputs for building stock energy models.Archetype methodology has recently received much attention, due to its extensive use in multiple scales, like the urban scale, the as called urban energy models (UBEMS), or at national and European scale. However, there is still no standard methodology to define buildings archetypes (Schaefer & Ghisi, 2016). The European TABULA project was the biggest initiative towards determining a common standard for archetypes development, implemented in twenty European countries concerning residential buildings (Loga et al., 2016). The energy modelling results with archetypes are highly altered by the parameters used to segment the building stock and the parameters definition step, adding errors due to assumptions and oversimplifications made in this process. For this reason, various approaches to determine the way the building stock is segmented have been developed. The most common are: (a) deterministic, (b) probabilistic and (c) clustering (Johari et al., 2020). The most used approach is deterministic segmentation, where simple classifications based on qualitative variables are made. Most used parameters for this purpose are year of construction, in order to determine the building materials and construction systems (driven by the technology development at the date and the building regulations), the energy systems properties and the buildings use typology (Borges et al., 2022). Other variables used are the Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 18 3. Methodology Figure 5 Methodology overview With the goal to evaluate how the building stock models developed on a national scale behave on a smaller scale (neighborhood), a methodology is proposed that is made up of the different steps shown in Figure 5. This methodology has been developed in such a way to compare the national building stock models with real data from the residential buildings of a neighborhood taken as a case study, accepting as “real data” the most reliable open database in existence, which is the Energy Efficiency Performance Certificate (EPC), with all the limitations it may have, Maria Karatsiompani MCTS | MISMEC 19 and given the fact that there is no public access to date to the real energy demands and consumptions of the neighborhood buildings. The national building stock models are compared to the EPC database, in terms of the façade and openings U values. U values are input data, determined in the characterization step of existing national building stock models in Spain. These variables were chosen for various reasons. The two thermal transmittance values determine the thermal properties of the envelope, that influence the thermal balance of the envelope and subsequently, the energy demand. There is existing literature suggesting that the thermal transmittance of the walls show significant influence for the heating and cooling energy consumption (Silva & Ghisi, 2020). At the same time, they are variables that are present both in the national building stock models and in the EPC database. Finally, they are variables that have a grade of uncertainty and can be altered when the building is renovated, information that is excluded by the archetype models but included in the EPC database. In the developed methodology, six main phases can be distinguished: national building stock models analysis, where some chosen segmentation models are further analyzed; territorial scope extension, where the limits of the case study used are determined; data preparation, which refers to the creation and processing of the database essential to the study; data segmentation, which consists of the division of the building stock in the case study, according to the criteria of the chosen segmentation models; and finally clustering classification, which has as objective to reveal patterns within the data that can help in the interpretation of the results, and finally, results mapping, where the segments of the national models and the clusters provided by the algorithm are mapped in the district case study. 3.1. National building stock models analysis From the existing national building stock segmentation methodologies, three of them were deeply analyzed to properly understand how they work and how they could be applied in the case study. A comparison analysis was performed in the set of reports of the Working Group for Rehabilitation GTR, the World Wildlife Fund for Nature (WWF) Energy Efficiency Report and the 2020 Update of the Long-Term Strategy for Energy Renovation in the Building Sector in Spain (ERESEE). The objective of this analysis is to comprehend how the building stock is segmented, which variables are consequently assigned to each segment, and which have uncertainty in the moment of this characterization. From these analyzed methodologies, the GTR set of reports and the ERESEE were the ones used for the comparison with the EPC database in the case study. Those two methodologies are considered the basic ones that establish the bases for energy retrofitting policies in the residential building sector in Spain and thus determine the interventions performed in the existing building stock in the next years. Since ERESEE is the evolution of GTR, it is interesting to understand to what extent the update of the methodology fits better with the reality of the building stock at a district level. Both use the same variables to segment the building stock into groups: year of construction, building typology and number of floors, making them suitable for the case study. The WWF Report was excluded from the comparison, since it follows a quite different structure, incorporating the urban planning state (detached and semi-detached buildings) and making hypothesis about the exact form of the buildings (whether the roof is habitable or not). The implementation of this methodology in the case study was considered difficult to apply, considering the available databases, as well as time-consuming, considering Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 20 the data treatment that the obtention of those variables would imply. For this reason, the WWF methodology comparison was considered out of the scope of this study. 3.2. Territorial scope extension Initially, the case study contemplated was La Pau neighborhood. The special interest for this neighborhood is due to the collaboration of the master’s program MISMEC, and IMU (Institute of Municipal Urbanism), aiming at the development of research and projects, within the framework of sustainable urban regeneration. Given this collaboration, La Pau held particular interest due to the relevant data availability, the ongoing efforts in the area and the existing synergies between local actors. However, this territorial scope was extended to the western coast of Besòs river, including Sant Marti, la Verneda i la Pau, el Besòs i el Maresme, Diagonal Mar and a part of Provençals del Poblenou neighborhoods, as shown in Cartography 2. The limits are defined by the postal codes divisions, which are the smallest territorial divisions available in the EPC database. This extension was considered vital to encompass a more extensive range of energy performance certificates and a greater diversity of buildings in terms of both construction period and typology. This is quite understandable, considering that La Pau is a working-class polygon, with multi-family blocks constructed during the same period of time and with similar construction techniques. To validate the territorial scope of the study, an initial analysis has been conducted on the EPC database. Dynamic tables in Excel were used to quickly visualize the resulting segments, using the construction regulations variable in the EPC database and the postal code. This territorial area is considered to have enough energy certifications, as well as diversity of different building types, as seen in Table 2. At the same time, all the neighborhoods included are in the process of urban renewal, being also one of the most vulnerable of the city of Barcelona. This adds more value to the study since it aims to contribute to the establishment of future renovation scenarios. Number of dwellings for Final territorial context (Postal Codes 8020 and 8019) Chronology Multi-family Single-family Total < 1979 8871 139 9010 1980 – 2007 1821 17 1838 > 2008 678 3 681 Grand Total 11370 159 11529 Table 2 Number of dwellings per segment in postal codes 8019 and 8020 Maria Karatsiompani MCTS | MISMEC 21 Cartography 2 Territorial scope of the study. The initially considered case study (La Pau) and the included neigborhoods are shown. 3.3. Data preparation 3.2.1 Data collection Overall, the databases used in the present study are the following: • The Energy Performance certificate database (EPC), provided by Generalitat de Catalunya, Department of Climatic Action, Food and Rural Agenda, • The Spanish Cadaster, • The census sections, provided by Cartographic and Geologic Institute of Catalonia (ICGC) and the Statistic Institute of Catalonia (IDESCAT) The EPC database provides data at a disaggregated building or dwelling scale. The energy certificate accreditation in residential use in Spain is obligatory in the case of new constructions, property sales or rentals, and renovations or extensions that affect the dwelling's surface or volume. The database covers the Catalan autonomous community, updated on a weekly basis and has a total of 1,44 million of lines, where each line is an energy performance certificate. This database provides a variety of data about the dwelling in a total of 71 columns, such as the location of the dwelling, the cadastral reference, the square meters, and the typology (single-family or multi-family) of the building. It also provides data about the energy efficiency certificate, such as the facades and windows transmittance, the energy demand and Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 22 consumption, and the respective emissions, as well as the qualification acquired. Additionally, it also provides georeferenced information, which allows its import in GIS tools. Overall, the EPC database provides a significant amount of useful data, creating an essential link between the known variables that are usually used to create the archetypes (construction year, building typology and number of floors), and the unknown data that are assigned to each archetype based on the overall knowledge of the construction techniques and a simplification of the variety of the characteristics of the building stock. However, it is important to underline the limitations and the quality of the data of the EPC database that occur for two main reasons. First, in the case of renovations, there may be a bias in thermal performance values with the intention of emphasizing the improvements made during the renovation. This can result in lower thermal performance values being applied to the certificate issued before the renovation. Second, the accuracy of the input data and the resulting energy certificate heavily rely on the technician's expertise and the level of detail involved during the inspection. In the case of existing buildings, their exact construction layers and materials are often unknown. A detailed diagnosis of the thermal properties can be a challenging task, requiring tests that are considered costly, difficult, or invasive for the user. For this reason, it is a common practice to apply default values based on the knowledge of the technician or as provided by the software. For example, by filling the year of construction and the location of the building, an estimation of the thermal transmittance of the building can be provided by the program. Therefore, the data in this database don’t represent the reality of the building stock, but rather an approximation that is the closest available representation of the reality. The EPC database, provided online by Open Data Catalunya, was downloaded and filtered using Microsoft access Database. The filtering criteria are the following: • Postal code 8020 and 8019, • residential use, • with existing transmittance values of holes and enclosures. The resulting database was exported in csv file for further processing. Since the database of the case study will be segmented according to the GTR and ERESEE methodologies, the EPC database was complemented by the cadaster database, to contain all the variables necessary for the segmentation. For the creation of the segments, it is necessary to have the construction year, the typology of the building (already available in the energy efficiency certificate database) and the number of floors above the street level. The construction year and the number of floors above the street level were obtained by two Cadaster databases: • Through the QGIS Inspire plugin, the “Buildings” layer has been used. • Through the cadaster website, using the “CONSTRU” shapefile layer. From the first database, the year of construction was obtained from the “Beginning” variable, while from the second the number of floors above ground was obtained from the “CONSTRU” variable. Obtaining the year of construction from this database and variable has been chosen as the most appropriate way, based on the study that has been carried out by Rehab (Sección de Urbanismo del Instituto Juan de Herrera, 2022) . Lastly, the exact study area limits were obtained by the census sections. Maria Karatsiompani MCTS | MISMEC 23 3.2.2 Database creation The three databases were joined together, processing the data in the following steps, as shown in Figure 6: Figure 6 Graphical overview of the database creation process A. Databases import in QGIS: All the databases were imported in QGIS. The EPC database was imported as a point layer, where each point represents an energy certificate for an entire building or a dwelling. The study area limits were created in QGIS, from the shapefile of the census sections. B. Both cadaster layers were clipped to the study area limits shapefile. C. The two cadaster shapefiles were joined using the “join attributes by location” function. At this point it is necessary to clarify that the “INSPIRE” layer has only the buildings in the plots, while the “CONSTRU” layer has a polygon for each subplot. For example, in Figure 7, the INSPIRE layer has three polygons, while the CONSTRU layer has 19 polygons, each with different values for the number of floors above the ground attribute, such as I, II, IV, ESC (stairs), -I, -I + VIII. The two layers were joined taking as base layer the one with the simplified polygons (INSPIRE), with the option “take attributes of the features with the largest overlap only”. In this way, the number of floors in the polygon with the highest representation of surface is attributed to the INSPIRE layer. The result is one single layer with the attributes of the INSPIRE layer and the attribute of number of floors above the ground level. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 24 Figure 7 Example of Inspire layer polygons on the left and CONSTRU layer polygons on the right. D. Reclassification of the number of floors above the street level attribute. In the cadaster, the nomenclature of this field has a complex format, composed by latin numbers. For example: -I + II represents the volumes below and above ground level. In this case the number of floors was modified to number 2. This transformation was done so that the variable could have a simple numerical format, making the segmentation step possible. E. Insertion of the variables year of construction and floors above ground into the EPC database for subsequent statistical analysis. The “join attributes by field value” function was used. This function joins variables between two layers, according to a common variable present in both layers. In this case, the cadastral reference number couldn’t be used, since the joined cadastral layer and the EPC database have different cadastral reference numbers. The EPC database has 20 digits, determining the dwelling scale and the joined cadastral layer has 14 digits, determining the building scale, as explained in Figure 8. In the EPC shapefile, a new attribute had to be created with only the first 14 letters of the cadastral reference. Then the “join attributes by field value” function was used, using the cadastral reference of the parcels and the short cadastral reference created, which are equivalent. Figure 8 Cadastral reference explanation per digits F. The EPC point layer was exported to a csv file, containing all the necessary information for the next step of the methodology. The resulting layers can be seen in Cartography 3, where the residential buildings and the number of energy performance certificates are visible. There is a total of 11.150 certifications. Maria Karatsiompani MCTS | MISMEC 25 Cartography 3 Residential buildings and Energy performance certificates. The number indicates the number of certifications. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 26 3.2.3 Database preprocessing The first step was the creation of the variables needed for the segmentation. In Excel, a new variable was created to divide the building stock in the construction periods necessary for the segmentation. For this new variable, two existing variables were used. First, the year of construction, taken from the cadastral layer, as previously explained, representing the specific year in which the building was constructed. Second, the regulation to which the dwelling/block applies, indicating the specific building codes or regulations that were in effect during the construction or renovation of each building, included in the EPC database. This variable has the following modalities: Before 1979, NBE-CT-79, NRE-AT-87, CTE 2006, CTE 2013, CTE 2019. NBE and NRE stand for the Normatives of construction of 1979 and 1987 respectively, and CTE stands for Building technical code. In order to include buildings that were renovated, meaning that the building complies with new regulations, the year of construction, as obtained from the Cadaster layer was used for buildings built before 1979, not complying to any existing construction regulation. The construction regulation variable from the EPC database was used as period of construction of the buildings after 1979. The division of the periods chosen was the more detailed one from the methodologies studied, which is ERESEE. The resulting building periods are: Before 1940, 1941 – 1960, 1961 – 1980, 1981 – 2007 and after 2008. The other important variable for the creation of the clusters, the building typology was also created as a new variable, simplyfying an existing variable in the energy certifications database, that is named as “Bulding use” and included various modalities explaining the typology of the building. These modalities were reclassified in a new variable called “Building typology”, including only two modalities: Single Family and Multifamily, giving an illustration in an easy- to-perceive way of the building typology. The second step was the detection of atypical values and their posterior correction or elimination, if the information they contained was incorrect, according to the case. These decisions were taken prior to a general analysis of the max and minimum values of the quantitative variables, as well as observing histograms and boxplots. In the variable number of floors, there were several rows that had a value of “0”. In this case, 0 is an invalid value, since the ground floor buildings have a value of 1, meaning that they have one floor above the street level. They were checked in the cadastral webpage and corrected manually, since it was few number of rows. As far as the U-values of the façade are concerned, they had initially a minimum value of 0,01W/m²K and maximum value 5,88 W/m²K. The values that are above 4 W/m²K and below 0,1 W/m²K were considered incorrect and thus were eliminated. In the case of the U-values, there are some values below the maximum limits specified in the current technical Code for Barcelona's climatic zone (C2). For façade U-values, the maximum limit is set at 0.49 W/m²K, while for openings U-values, the limit is 2.1 W/m²K (Código Técnico de La Edificación (CTE) Documento Básico de Ahorro de Energía (DB-HE), 2022). Those cases have been analyzed separately, to understand whether they are incorrect values, or they have been renovated without changing the regulation to which the building is complying. Since there was no further knowledge about these values, they were maintained in the dataset. Other variables that were considered to have atypical values were the primary energy consumption and the residential surface. For the non-renewable primary energy consumption Maria Karatsiompani MCTS | MISMEC 27 variables, two values were considered incorrect, since they were extremely high (13.746 and 3.107,2 kWh/m2year). Both were checked in the database of the energy certificates. The first was corrected since its value was conflictive with the one on its energy certificate, and the other one was eliminated. In the residential surface variable, 200 rows with value 0 were detected. They were checked in the cadaster and filled manually according to the cadaster housing surface. Other small values were corrected in the same way. Some extreme values were also checked on the cadaster website and corrected. 3.4. Data segmentation according to GTR and ERESEE criteria After the final database was created and preprocessed for the territorial case study, the segments according to the selected methodologies were created, as shown in Table 3. Two new variables named GTR and ERESEE were added in excel, where the different segments´ names were applied, by filtering the database according to the criteria of each segment. Building Segments Single - family Multi - family Number of floors < = 3 > 3 GTR ERESEE GTR ERESEE GTR ERESEE Urbanization dimension < 10.000 inh < 10.000 inh >100.000 inh <= 1940 (A) Uu < 40 NA1 Cc < 40 B Bb < 40 1941 - 1960 Uu 40 - 60 Cc 40 - 60 Bb 40 - 60 1961 - 1980 (C) Uu 60 -80 NA2 Cc 60 -80 F Bb 60 -80 1981 - 2001 (G) Uu 80 - 07 (H) Cc 80 - 07 J Bb 80 - 07 2002 - 2007 2008 - 2020 Uu 08 - 20 Cc 08 - 20 Bb 08 - 20 Table 3: ERESEE and GTR proposed segmentations of the building stock. Both methodologies produce similar segmentation of the building stock, but with some notable differences. The GTR method results in nine segments, whereas ERESEE identifies fifteen segments. However, ERESEE offers a more detailed temporal division, spanning every 20 years from 1940 onwards, while GTR only divides the building stock into three periods, starting from 1960. They both use common segmentation between single-family, multi-family houses with up to three floors and multi-family buildings with more than three floors. However, GTR segmentation incorporates the dimension of the housing environment (i.e., rural, medium urban or urban), and selects the ten segments with the highest concentration of dwellings. In the case of urban environments with over 100,000 inhabitants, only three segments were analyzed in GTR. Nevertheless, the other segments denoted in parentheses (A, C, G, H) will be visualized in this research for educational purposes. Also, there was no segment chosen in the GTR methodology for multi-family buildings of less than 3 floors, constructed before 1980 as it was an archetype little represented/not relevant at the Spanish/national level. Since the GTR methodology lacks characterization for these segments, a direct comparison is not feasible. Despite this, these segments, referred to as NA1 and NA2, will still be represented in the study. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 34 o Housing typology: The study considers three types of buildings: detached single-family houses, semi-detached single-family houses, and multi-family housing blocks. Each type is further analyzed with two different building models, resulting in a total of six buildings studied. - Detached single-family buildings are standalone buildings with openings on all sides. Two situations are considered: habitable attic space and non-habitable attic space. - Semi-detached single-family buildings are represented by two common scenarios: a row of six houses with openings on the main and opposite facades (common in Spain in the 1980s) and a single house with a nonhabitable attic space. - Multi-family housing blocks are represented by two models: the first scenario is a building between party walls, while the second scenario replicates the building in a closed city block. o Climate zone: The study reclassifies the twelve established climatic zones in the Technical Building Code into three zones with similar winter and summer severities. - Zone B4 (Seville) includes A4, A3, B4, B3, and C4. - Zone D3 (Madrid) comprises C3, C2, D2, and D3. - Zone E1 (Burgos) encompasses C1, D1, and E1. o Construction period: The residential building stock is divided into historical periods that determine the construction characteristics and thus, the thermal properties. Homes are distinguished between those built until 1945 and those constructed after this date, covering the era after the Spanish Civil War. Additionally, they are categorized by the technical regulatory framework, distinguishing homes built before 1980 and those built after. Segmentation variable Distinction Housing age < 1945 1945 - 1980 1981 - 2008 Housing typology Detached single-family buildings Semi-detached single-family buildings Multi-family housing blocks Climate Zone B4 D3 E1 Table 6 WWF Segmentation variables and distinction 2. Characterization of variables considered: Figure 9 shows how specific values to each property of the case studies are determined according to the segmentation variables. The values used for the thermal characteristics of the building envelope (opaque and semitransparent elements) and other parameters affecting the energy efficiency of the buildings were taken from the prevailing thermal regulations in the year of each building's construction, where available. Since thermal regulations are different for each climatic zone, these variables depend both on the construction period and on the climatic zone. In cases where such regulations were not present, typical solutions from that era were used. The Maria Karatsiompani MCTS | MISMEC 35 specific values to each thermal characteristic of the buildings were assigned according to the chronological distribution established. On the contrary, geometrical characteristics for each case study were assumed according to the housing typology and the case studies that were established for each typology. Figure 9 Dependance between the segmentation variables and the variables used for energy demand calculation (WWF). 3. Energy demand calculation for current situation of the building stock and five different improvement scenarios. The energy demand is simulated for all the case studies in each segment, using as input data the values specified in the characterization step. The study employs the General Option as determined in the Basic Document HE1-CTE, which involves an hour-by-hour transient analysis of the thermal behavior of the building, considering both external and internal loads simultaneously and accounting for the effects of thermal mass. The LIDER computer application is used for this purpose, providing data on heating and cooling energy demand based on climatic conditions and building Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 36 parameters. Different thermal installations were also considered for all the cases. The results are further processed using the official Energy Certification of Buildings program (CALENER) to calculate energy consumption and CO2 emissions. This process is applied in all six scenarios, including the current situation scenario. An overview of the methodology is provided in Figure 10, where the dendroid structure is visible. In this methodology, for each type of building 51 cases were considered for each climatic zone. Since the climatic zones considered are three, a total of 153 cases studies per type of building were considered. In total the study considers six housing typologies (two case studies for the three typologies), leading to a total of 918 case studies analyzed. Figure 10 Overview of the WWF methodology. Source: (World Wild Fund for Nature, 2010) Maria Karatsiompani MCTS | MISMEC 37 4.2. The Working Group on Rehabilitation (GTR) set of reports The Working Group on Rehabilitation (GTR) aims to promote the transformation of the current building sector, which is focused on new construction, into a new approach that prioritizes the creation and maintenance of socially necessary habitability. Within this scope, the GTR seeks to establish an economically viable and job-generating housing sector that ensures the right to housing and addresses the environmental and social challenges of Global Change. The GTR is composed of various experts and aims to define an action plan that enables these transformations and highlights the importance of rehabilitation as a key to achieving these goals. The GTR has published a set of reports (Casanovas et al., 2018; Cuchí & Sweatman, 2011; Cuchí i Burgos et al., 2012) that represent a first approach to an intervention strategy in the building stock. These reports are a reference for the renovation strategies of the building stock incorporating new legislative guidelines from the European Union’s new Energy Efficiency Directive, as well as new national and international processes and developments in the field. The GTR report of 2011 (Cuchí & Sweatman, 2011) sets the base of the methodology applied in the set of reports. The database used for this study was the most recent national census at the date, which was conducted in 2001, as the census is carried out every ten years. It provides data on a disaggregated building level. The GTR methodology follows a deterministic segmentation approach. Since the database used refers to a disaggregated level, it is a bottom-up technique. First, the building stock is divided into groups of similar buildings according to qualitative variables. The more quantitatively significant groups are chosen (the hotspots), and then geometrical and thermal properties are assigned to each of them. Then the interventions to be developed per each hotspot are determined. Energy demand is calculated for each group´s given properties before and after the intervention proposals. Finally, the total impact of the interventions is assessed in terms of energy efficiency, greenhouse gas emissions reduction and financial costs, by multiplying the results by the number of houses of each housing group. The different steps are further analyzed in continuation. 1. Segmentation of the existing residential building sector: The segmentation of the building stock proposed is based on four variables: Housing age, Building height, housing environment and housing typology. An overview of the distinctions considered in each segmentation variable is seen in Table 7. o Construction age: Based on the construction characteristics, homes are distinguished between those built until 1960 and those constructed after this date. Additionally, they are categorized by the technical regulatory framework, distinguishing homes built before 1980 and those built after. o Building height: Homes are categorized into two groups based on the number of floors: up to three floors and more than three floors. This classification considers the construction systems of facades, roofs, etc., and the proportions between them and the living area. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 38 o Housing environment: The housing environment is divided into the following categories: - Rural areas: Less than 10,000 inhabitants. - Small and medium urban environments: 10,000 - 100,000 inhabitants. - Urban conglomerates: More than 100,000 inhabitants. o Building typology: The building stock is categorized between single-family and multifamily buildings. This categorization primarily considers the administrative implications of intervention, whether it occurs within a community (multi-family) or with a single owner (single-family). Table 7 GTR Segmentation variables and distinction Segmentation variable Distinction Housing age < 1960 1960 - 1980 1981 - 2001 Building height 1- 3 floors > 3 floors Housing Environment < 10.000 inhabitants 10.000 – 1000.000 inh. > 100.000 inh Building Typology Single-family Multi-family 2. Determination of the hotspots: Hotspots in GTR methodology are considered groups of buildings with homogenous characteristics that are quantitatively significant. The GTR report in 2011(Cuchí & Sweatman, 2011) segmented the building stock into 10 segmentshotspots that represent 75% of the residential sector in Spain. The result can be seen in Table 8, where the hotspots are highlighted in green. Maria Karatsiompani MCTS | MISMEC 39 Table 8 Number of houses GTR segment. The selected hotspots are highlighted. Source: (Cuchí & Sweatman, 2011) 3. Characterization of each hotspot. During the characterization step, some assumptions are made, depending on the values of the qualitative variables used for the segmentation, according to a base case consideration of surface areas and thermal properties which determine a typical Spanish home profile. Figure 11 illustrates the relationship between the segmentation and the characterization variables, where the second can be inferred from the first. Geometric properties are determined by housing typology and number of floors, while thermal transmittances depend on different segmentation variables each. Window transmission, ground floor thermal transmission, ventilation and appliance gains are assumed to be the same for all the segments. 4. Current energy demand calculation. Current energy demand is calculated performing a static thermal balance, based on two determining factors: the transfer of heat through the building envelope and its ventilation losses. The variables used for the thermal balance and an example of the calculation can be seen in Table 8. It is obvious that some simplifications are made, for example in the case of ventilation losses that are hard to quantify. The impact of the occupants is de facto considered as GTR assumes the same occupation before and after intervention. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 40 Figure 11 Dependance between the segmentation variables and the variables used for energy demand calculation (GTR) 5. Determination of the interventions to be developed per hotspot and calculation of future energy demand. The previously determined variables used for the current energy demand calculation are updated according to the interventions proposed in each segment. The future energy balance is calculated by the thermal balance methodology, as before, but with updated variables. This simple way of calculating the energy demand makes possible the study of different intervention possibilities and finally the assessment of the most appropriate for each housing segment. 6. Assessment of financial impacts and greenhouse gas emissions reduction. The introduction of financial variables the financing interest rate, loan maturity, up-front subsidies, rebates, or fiscal supports makes possible to understand the financial impact of the interventions and its sensitivity and dependence on various economic factors. The GTR model also determines the energy and emissions savings discounted at the cost of the financial investment. Maria Karatsiompani MCTS | MISMEC 41 Table 9 Current heating energy demand calculation in GTR methodology. Source: (Cuchí i Burgos et al., 2012) Table 10 Future energy demand calculation in GTR methodology. Source: (Cuchí i Burgos et al., 2012) Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 42 4.3. The long-term Strategy for energy renovation of the building sector in Spain (ERESEE) The long-term Strategy for energy renovation of the building sector in Spain (Ministry of Transport Mobility and the Urban Agenda, 2020) establishes a roadmap for the decarbonization of the building stock by 2050. It is an answer to the obligation of each member state of the EU to establish a long-term renovation strategy, according to the Directive (EU) 2018/844. This strategy supports the renovation of the national stock of residential and nonresidential buildings, both public and private, into a highly energy efficient and decarbonized building stock by 2050, facilitating the cost-effective transformation of existing buildings into nearly zero-energy buildings. ERESEE methodology follows a similar approach as the ones analyzed in the previous chapters. First, the residential building stock is segmented in groups/clusters of buildings that allow the identification of the number of dwellings in each chosen cluster for each province. Subsequently, the aggregated energy demand per group is calculated, and a typical rehabilitation menu is assigned to each cluster. The goal is to determine the energy and emission savings that can be achieved and the necessary investments for implementing the rehabilitation measures. The database chosen for this study is the Census of Population and Housing, which corresponds to the year 2011. Taking into account the database used and the methodology applied, it follows a deterministic archetype approach. The basic steps or the methodology are outlined subsequently. 1. Segmentation of the residential building stock (de Santiago, 2019). The segmentation variables used for this study are the construction year and the housing typology, that includes the number of floors. An overview of the distinctions considered in each segmentation variable is seen in Table 11. The result of this segmentation are fifteen representative segments, as seen in Table 12. o Construction year: ERESEE methodology is the one dividing the building stock into more periods than the rest (<1940, 1941-1960, 1961-1980, 1981-2007, 2008-2011). The dates correspond to the main changes in the technical building regulations and the most common construction systems in Spain, highlighting the NBE-CT 79 (1979), which introduced the first energy efficiency requirements in Spain and the Technical Building Code of 2007. o Building typology: The housing typology, integrating the number of floors of the building, is divided into the following categories: - Single-family buildings - Multi-family buildings until three floors - Multi-family buildings with more than 3 floors Maria Karatsiompani MCTS | MISMEC 43 Segmentation variable Distinction Housing age < 1940 1941 - 1960 1961 - 1980 1981 - 2007 2008 - 2011 Building typology Single-family buildings Multi-family buildings until three floors Multi-family buildings with more than 3 floors Table 11 ERESEE Segmentation variables and distinction Table 12 Resulting segments in ERESEE methodology 2. Characterization of the different segments. The division into construction periods, defined according to the main technical or regulatory changes in Spain, makes it possible to assign dominant construction systems in each period to each cluster, also inferring the degree of insulation of the envelope and its characteristics. The geometric characteristics were defined according to the urban areas corresponding to each cluster, identified through the Cadaster website. Representative real examples of single-family and multi-family buildings were selected for each cluster. Parameters defining typical volumetric characteristics of each cluster were obtained, such as the relationship between the front and depth of the buildings. The geometric data from these examples were used to calculate envelope surfaces (floor, roof, walls, openings) per dwelling and per 100 m2. Average floor areas for each cluster were derived from previous studies based on Census data, providing detailed information on construction periods and distinguishing between single-family and multi-family typologies. The orientation was also defined since it affects the solar radiation gains of the exposed surfaces. It has been assumed that 50% of the building stock has North-South orientation and 50% East-West orientation. The exterior temperatures were calculated for each province. Other variables that were assumed as equal for all the segments are the inertia coefficient, the interior temperature and the internal gains. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 50 Figure 19 Heating energy demand boxplot (left) and histogram (right). The U-values of the façade, have a minimum value of 0,11 W/m²K and a maximum value of 3,3 W/m²K, with a median of 1,75 W/m²K and a mean value of 1,76 W/m²K, very close to the median. It is important to note that the maximum U-value of contemporary thermal legislation (0,49 W/m²K), is placed outside the whiskers of the boxplot. This means that this value is significantly different from the rest of the data points. The first Quartile of the boxplot, which represents 25% of the total values is at 1,69 W/m²K, which is more than three times the legislation maximum U value. In total there are 297 dwellings with less or equal to this value, meaning only 2,7% of the whole dataset. This further highlights the poor thermal performance of the existing building stock in the case study and should be considered in future renovation strategies. In the histogram of Figure 20, right panel, we can observe the accumulation of occurrences in two values, between which the median value is placed, while a third peak is also observed, where the lower whisker ends. Figure 20 Average façade U-vales boxplot (left) and histogram (right) Maria Karatsiompani MCTS | MISMEC 51 The U-values of the openings, have a minimum value of 1,11 W/m²K and a maximum value of 6,79 W/m²K , with a median value of 4,78 W/m²K and a mean value of 4,63 W/m²K. In this case, the maximum U-value of contemporary thermal legislation (2,10 W/m²K), is placed in the lower whisker. There are 48 dwellings with less or equal to this value, meaning only 0,43% of the whole dataset, which is an impressively low percentage. Figure 21 Average openings´ U-vales boxplot (left) and histogram (right) Through this description of the basic thermal related characteristics of the residential building stock in the case study, it becomes evident that its the thermal performance is poor highlighting the crtical need for energy retrofitting. The latest revision of the Directive on the energy performance of buildings in December 2021 has raised the minimum building energy performance standards, aligning with the European Union's ambitious goal of reducing greenhouse gas emissions by 55% and achieving climate neutrality by 2050. In this context, all residential buildings must undergo renovation to achieve a minimum energy efficiency rating of class F by 2030 and class E by 2033. In the present case study this would mean that 10% of the existing building stock must undergo energy renovations by 2030, increasing to 20% by 2033. The need for energy retrofitting is further validated by the fact that the actual non - renewable primary energy consumption’s and the heating demand’s mean values are more than three times the established regulations’ maximum values. Analyzing the U-values of façades and openings, only 2,7% and 0,43% respectively of the building stock complies with the current legislation. Poor thermal transmittances in buildings significantly impact thermal comfort and total energy consumption. High thermal transmittance leads to increased heat transfer between the interior and exterior of the building, requiring more energy for heating in winter and cooling in summer to maintain basic habitability requirements. The fact that the studied part of Barcelona consists of lower income neighborhoods raises concerns about the conditions of the residents during extreme temperatures. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 52 6. Results 6.1. Creation of the GTR segments in the territorial context Cartography 4 GTR segments in the case study Maria Karatsiompani MCTS | MISMEC 53 The GTR segments were created for the case study as seen in Cartography 4. In the case study of the present thesis, since it is an urban environment with more than 100.000 inhabitants, GTR considers only three segments, all of them multifamily houses. Single family houses would be excluded because the number of buildings is not enough to be considered as a hotspot in the GTR methodology. For educational reasons, those segments that would be ignored in GTR methodology are going to be visualized with grey color, so that they are recognizable. Since the chronological segmentation of GTR methodology is not very detailed, bigger groups of same-colored buildings, the one next to the other, are visible in Cartography 4, making visible the construction period of the neighborhoods. Table 13 displays the number of dwellings per GTR segment. There is a substantial variance in the number of dwellings across the segments, ranging from as few as 14 to almost 6.000 dwellings. As expected, there is an overall low count of single-family buildings, with segments containing only 14 to 87 dwellings. Conversely, there are segments with an impressive number of dwellings, such as multi-family buildings with more than three floors built before 1960, totaling 2.173 dwellings, and those built between 1960 and 1980, which house 5.842 dwellings. As we can see in Figure 22, half of the buildings (52,4%) are multi-family buildings with more than 3 floors, built during the period 1960 – 1980. A total of 8,7% of the residential building stock would not be considered in the GTR methodology, shown in table 13 with red color, since they are either single family houses, or multifamily houses with less than 4 floors. GTR Single - family Multi - family Number of floors [1 - 3] < = 3 > 3 Urbanization dimension < 10.000 inh < 10.000 inh > 100.000 inh < 1960 (A): 87 NA1: 223 B: 2.173 1960 - 1980 (C): 36 NA2: 307 F: 5.842 > 1981 (G): 14 (H): 307 J: 2.159 Table 13 Number of buildings per GTR segment in the case study Figure 22 GTR segments in the case study pie chart Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 54 6.2. GTR - U Values overview In Figure 23, which illustrates the U value of façade (x-axis) and openings (y-axis), colored by the different segments of the GTR methodology, it is evident that default values are employed in the EPC database. The scatter plot displays distinct vertical (U-value of 1,69 and 2,38 W/m2K) and horizontal lines (U-value of 3,78 and 5,7 W/m2K), which suggest frequently applied default values for these parameters. This conservative approach leads to an overall cautious representation of the existing building stock in the EPC dataset, as it was expected and already commented previously. This result is aligned with previous studies that use the EPC database (De Jaeger et al., 2021), underlying the need to improve current procedures for the energy certificate, as well as the need to interpret the results with care. Figure 24 shows a matrix of scatter plots for the U values (façade U value on the x-axis and openings U value on the y-axis), each representing a segment of GTR segmentation methodology. It serves as a supplement to Figure 23, since we can see each segment apart, allowing a better evaluation of the U values of the different segments. Horizontally, the matrix displays various types of dwellings, with the first row representing single-family dwellings, the second row for multi-family dwellings with up to three floors, and the third row for multi-family dwellings with more than three floors. Vertically, the matrix is organized based on the construction periods used, ranging from before 1960 to later than 1980. The red dot represents the two U values, as determined by the GTR segmentation methodology, during the characterization step. In those visualizations we can see that the U values tend to decline in most recent years, since the points tend to concentrate from the upper right part to the lower left part. We can observe in segments H and J a concentration of points in the lower left part, that probably represent the buildings built after 2008. However, they are not separated into a different segment since GTR methodology is the oldest segmentation proposal studied. Moreover, single-family buildings (A, C, G) seem to be more concentrated in the upper right part of the scatterplots than the rest of the housing typologies for the same construction periods. Maria Karatsiompani MCTS | MISMEC 55 Figure 23 Relation between façade (x axis) and openings (y axis) U-value per GTR segments Figure 24 Relation between the U values, divided per GTR segment on each graph. Red points are the determined from GTR methodology values. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 56 Figure 25 Façade U-values overview boxplot per GTR segment. With red lines, the determined from GTR methodology values. Maria Karatsiompani MCTS | MISMEC 57 Figure 26 Openings´ U-values overview boxplot per GTR segment. With red lines, the determined from GTR methodology values. Figures 25 and 26 provide a clear visualization of the declining trend in U values over time, specifically after 1980. This decline is evident for both façade U values and openings U values. Interestingly, the boxplots show similar overlapping boxes during until 1980, suggesting a comparable range of U values for all housing typologies. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 58 After 1980, the façade U values exhibit a wide range of values across all building typologies (G, H and J). This is also obvious in the histograms of these segments. For example, in Fgure 27, where we can see two peaks in the distribution of the façade U values of segment H. This can be attributed to the incorporation of various construction techniques during this time, leading to a greater diversity of U values. Conversely, the openings U values exhibit smaller boxes after 1980, particularly for single-family buildings and multi-family buildings with less than three floors (G and H). This indicates a distribution of more limited range of values for these building categories during this period (Figure 28). However, for multi-family buildings with more than three floors, constructed after 1980 (J), the whiskers in the graph are notably wider, indicating a significant variation in U values. Moreover, there are numerous values considered outliers (the points beyond the whiskers) in this category. This could be attributed to the considerable advancements in openings' thermal transmittance that have occurred since 1980, leading to a broader spectrum of values being encompassed during this timeframe. The complete results in boxplots and histograms for all segments can be found in Annex 1. 6.3. GTR deviation assessment To assess the difference between the U values in the GTR methodology (shown in figures 25 and 26 with red lines) and the values in the EPC database, the deviating percentage, as explained in Equation 3, has been used. The results are shown in Table 14. The results show great percentual differences between the values assigned by GTR method and the segments created by the EPC database. The consideration of one unique U value for the openings in GTR (5,7 W/m2K), has resulted in overrating all the segments, with deviations from -8,95% to -36,05%. The greatest deviations take place in the most recently constructed building stock. As far as façade U values are concerned, we can see the opposite. Most of the building stock has been underestimated, with deviations in the façade U values of up to 238%, in the case of Figure 27 Facade U value histogram of segment H Figure 28 Openings U value histogram of segment H Maria Karatsiompani MCTS | MISMEC 59 multi-family buildings of less than 3 floors. At the same time, high values of positive deviation are obvious in the rest of the segments, especially in the periods 1960 – 1980 and 1980 and on. GTR segment Median façade U Value (W/m2K) GTR façade U value (W/m2K) Median openings U value (W/m2K) GTR openings U value (W/m2K) % U façade deviation % U openings deviation (A) 2,26 1,9 4,91 5,7 18,95% -13,86% (C) 2,17 1,3 4,03 5,7 -11,67% (G) 1,69 0,5 3,64 5,7 NA1 1,88 1,9 4,97 5,7 -1,05% -12,81% NA2 1,78 1,3 5,00 5,7 36,92% -12,28% (H) 0,73 0,5 3,78 5,7 46% B 1,93 1,9 5,19 5,7 1,57 % -8,95% F 1,92 1,3 5,00 5,7 47,69% -12,28% J 0,82 0,5 3,78 5,7 62,00% Table 14 Facade and openings mean U values and performance gap, per GTR segment. The two highest positive and negative percentages for each U-value are highlighted. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 66 In the façade U value boxplots (Figure 32), all boxes until 1980 are the same, across all housing typologies, indicating that that 50% of the data points have similar spread, meaning that they have considerable similarity within this range. The similarity in the size and the overlap across those segments raises questions about the significance of the difference in the thermal transmittance of the segments. Nevertheless, they have differences in the median position, which shows the central tendency. Single-family houses (Cc) have higher median positions, multi-family with less than 3 floors have lower median positions (except for pre-1940), and multi-family with more than 3 floors have medians towards the middle. This may be influenced by the data size, making the median more sensitive to fixed values (e.g., 1.69 and 2.38 W/m2K). We can also see that façade U values in the period 1980 – 2007 (Uu 81 - 07, Cc 81 - 07, Bb 81 – 07) have the biggest box and in the case of the two last, also the longest whiskers. This means that 50% of the values in these groups are spread out over a wider range compared to the others, also indicating a higher degree of variability or dispersion. This can be explained by a greater diversity in construction techniques applied during this period. In Figure 34 we can see two subgroups within the histogram of façade U value of segment Bb 81 – 07, contributing towards this explanation. When analyzing the U values of openings, there are several segments that exhibit a left-skewed distribution, as indicated by the median positioned towards the top of the box plot and the presence of only the lower whisker. This left-skewed pattern may be influenced by the default U value of 5.7 W/m2K for openings, which results in a high concentration of data points. This concentration creates a 'ceiling effect,' where values tend to cluster around and below this default value, leading to the observed left-skewed distribution. At the same time, this great variability for lower openings U values could be explained by window replacements. Figure 35 shows an example of the distribution of the U values, where the left skewed distribution is clear. After 1980, openings U values tend to have more compact boxplots, with less variation in the values. This could possibly be explained by either a more limited and regulated use of windows in the territorial context or the compliance with Figure 34 Bb 81 - 07 facade U value histogram. With red line the ERESEE default value Figure 35 Bb 40 - 60 openings U value histogram Maria Karatsiompani MCTS | MISMEC 67 thermal regulations established after the 80s. The complete results in boxplots and histograms for all segments can be found in Annex 2. 6.6. ERESEE deviation assessment To assess the difference between the U values in the ERESEE methodology (shown in figures 32 and 33 with red lines) and the values in the EPC database, the deviation percentage, as explained in Equation 3, has been used. The results are shown in Table 16. Negative performance gap indicates that the EPC median value is smaller than the ERESEE assigned value, and thus the thermal transmittance has been overestimated by ERESEE. This implies that the thermal performance of the building stock is better than expected. On the contrary, positive performance gap indicates that EPC values are higher than the ERESEE determined value, and thus the U value of the segment has been underestimated by the method. This implies that the thermal performance of the building stock is worse than expected. As a general observation, we can see that between the ERESEE characterization and the EPC database, there are multiple deviations of around 20% to 30%, with maximum deviation of 38%. The results show that U values of buildings after 1980 have been overestimated, since they have high values of negative deviation percentages, while U values before 1980 have generally been underestimated, since they have in most segments positive percentages of deviation, with the highest ones in the period 1960-1908. This can be seen more clearly in openings U values, that also have the biggest percentages of deviation both negative-wise and positivewise. Moreover, multi-family buildings with less than three floors have a slightly different behavior since façade U values have been overestimated for all the segments. It is interesting to notice that ERESEE applies almost the same façade U values for single-family and multifamily buildings with less than three floors, but in the second case the EPC values are lower. ERESEE segment Median façade U Value (W/m2K) ERESEE façade U value (W/m2K) Median openings U value (W/m2K) ERESEE openings U value (W/m2K) % U façade deviation % U openings deviation Uu < 40 2,26 2,12 4,44 4,24 6,60% 4,72% Uu 40 - 60 2,27 2,12 5,08 4,24 7,08% 19,81% Uu 60 - 80 2,38 1,85 5,02 4,24 18,40% Uu 80 - 07 1,48 1,5 3,65 4,69 -1,33% Cc < 40 2,07 2,12 4,64 4,24 -2,59% 9,43% Cc 40 - 60 1,69 2,08 5,16 4,24 -18,75% Cc 60 - 80 1,78 1,5 5,00 4,24 17,92% Cc 80 - 07 0,93 1,5 3,78 4,69 -19,40% Cc > 08 0,65 0,95 3,64 4,4 -32,11% -17,27% Bb < 40 2,05 1,94 4,90 4,24 5,67 % 15,57% Bb 40 - 60 1,90 1,81 5,25 4,24 4,70% Bb 60 - 80 1,92 1,68 5,00 4,24 14,29% 17,92% Bb 80 - 07 1,00 1,5 3,78 4,69 -19,40% Bb > 08 0,66 0,95 3,44 4,4 -30,53% Table 16 Facade and openings mean U values and performance gap, per ERESEE segment. The two highest positive and negative percentages for each U -value are highlighted. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 68 6.7. K-means Clustering Cartography 6 K-means clusters in the case study Maria Karatsiompani MCTS | MISMEC 69 Cartography 7 Number of k-means clusters per building Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 70 In Cartography 6 we can see the resulting k-means clusters in the case study. The resulting clusters have been named from better to worse combination of U-values: 1, 2a, 2b, 3a, 3b, 3c, 3d, 4a, 4b, 5. Consequently, in cartography 6, yellow color represents the most favorable U- value combination, while purple color signifies the least favorable combination. The Silhouette method identified 10 optimal clusters, with the best combination of clustering variables being the façade and openings U-values. The resulting clusters found to have a Between sum of squares / Total sum of squares of 93,3%, meaning that this is the percentage of the total variance in the data set that is explained by the clustering. Comparing the map with the other two maps, we can see that there are less patterns of same clusters in neighboring buildings, although they were built in the same period and probably with the same technique. The clusters are spread in the neighborhood with more variability and heterogeneity. It is interesting to outline the fact that adding other variables used by the previous methodologies to segment the building stock, such us the period of construction, a variable that can theoretically explain until certain point the building stock U values, provided worse results in the clustering k-means algorithm. Also, it needs to be underlined, that the map shows the buildings colored according to the cluster that is characterizing most of the dwellings in the building. This is a way to visualize on a map, buildings that contain dwellings belonging to different clusters. Cartography 7 shows the number of clusters per building, which is a very important added knowledge. We can see that there are buildings with 1 to 10 clusters and a lot of them with intermediate values. Table 17 Number of dwellings per K-means Cluster Cluster 1 2a 2b 3a 3b 3c 3d 4a 4b 5 N. of dwellings 334 1.209 1.897 426 113 593 954 2.157 812 1.629 % 3.0% 10.8% 17% 3.8% 10.2% 5.3% 8.6% 19.3% 7.3% 14.6% In table 17 we can see that clusters contain dwellings from 113 (cluster 3b) to 2.157 (cluster 4a), which is contrasting to the distribution of the segments from previous methodologies, that showed great variance in the size of the segments. As a percentual expression, we can see that the three biggest clusters (4a, 2b and 5) represent 51% of the building stock, while the smallest clusters (1 and 3a), both with good thermal performances, represent around 3 to 4% of the case study. Figure 36 shows the previously shown scatterplot, where the façade u values are in the x axis and the openings U values are in the y axis, with the clustering result in different colors and the shapes of the limits of the clusters. We can see that the resulting clusters are compact and separated from each other without overlapping, indicating distinct patterns within the dataset. However, there are some clusters that are very close to each other, that were probably attracted by the default values on the dataset, as we can see with vertical and horizontal lines. This suggests that the default values have a strong effect in the clustering result. Maria Karatsiompani MCTS | MISMEC 71 Figure 36 K-means clusters result on Façade (x axis) and openings (y axis) U-values (W/m2k). The values are normalized. When visualizing the U values in boxplots (figure 37), we can observe that the boxes are much smaller than the ones from the previously studied methodologies (ERESEE and GTR). We can also observe that high façade U values (for example clusters 3c, 3d, 4b and 5) don’t necessarily have high windows U values. Of those, only clusters 5 and 4b have high both façade and windows U values. This underlies the fact that there is no direct relationship between the two values, meaning that higher thermal performance of the façade (low façade U values) doesn’t necessarily mean high performance of the openings (low openings U values), and vice versa, a claim that could be relevant. Buildings that perform well in one part of the building are expected to have better performances in the other parts of the building as well. This was already visible in the scatterplot of the two U values, since the points in the plot don’t follow a clear linear pattern (figure 36), meaning that one U value does not grow linearly with the other U value. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 72 Figure 37 Facade (left) and openings (right) U-values overview boxplot per cluster. The other qualitative variables previously used to segment the building stock, were also checked for each cluster to understand if there is some clear relationship between them and the resulting clusters. The number of floors and housing typology didn’t provide any further information for the characteristics of the buildings in each cluster. Single family buildings, that also represent a very low percentage in the territorial context were present in all clusters and they were not separated into one specific cluster. This suggests that there is no clear pattern between housing typology (multi-family and single-family) and the thermal transmittances of the building stock. The same results apply to the number of floors, since all the clusters have a variety of heights and there is no cluster that contains only higher or only lower constructions. The construction period of the clusters was also plotted in pies, where each pie represents a period of construction, while the color fill represents each cluster found in the dataset (Figure 38). No obvious relationship between the cluster’s formation and the year of construction can be seen, meaning that there is no cluster that is only constructed during one period, but rather the clusters are formed by buildings constructed in different periods. We can although observe that there are some periods of construction that have higher percentages in some clusters. For example, dwellings built after 2008, are mainly represented by clusters 2a and 1. At the same time, cluster 2a has a big percentage of buildings built between 1980 and 2007, and for the earliest construction periods, the percentages of this cluster are significantly lower. The period before 1940 is well divided between clusters, but clusters 4b and 5 are more present in the earlier construction periods (until 1980). Maria Karatsiompani MCTS | MISMEC 73 Figure 38 Period of construction of each cluster pies charts. Figure 39 Cluster results boxplots organized by the highest to the lowest heating energy demand. The different plots show the heating energy demand (up left), the openings U value (up right) and the windows U value (down left). Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 74 The heating energy demand for each cluster was also plotted, to evaluate the effect of this classification. The clusters in the plot were reorganized from the highest energy demand to the lowest, and then the two U values boxplots were plotted again according to this reorganization (figure 39). From this reorganization we can see that the façade U values follow the energy demand: higher energy demand is found in the clusters with higher façade U value and vice versa, almost following the same row as the clusters in energy demand, apart from clusters 3a and 3b that have lower façade U values than the clusters before them, 2b and 3d respectively. The same behavior is not observed in the windows U values since they are not properly organized from higher to lower value. Cluster 1, that has the lowest energy demand, also has the lowest U -Values, and includes most buildings built after 2008. Similar behavior can be observed in cluster 2a, the second with less heating energy demand. Maria Karatsiompani MCTS | MISMEC 75 7. Conclusions and future work Current Spanish strategies for energy retrofitting policies are based on deterministic archetype methodologies of diagnosis. The objective of this study was to evaluate the reliability of these strategies altering the scale of implementation and testing them at a district level, through a case study. In this section, the most important parts of the previously presented results are highlighted and extended into future approaches. Both GTR and ERESEE methodologies have been successfully represented in the case study making use of both the EPC and the cadastre databases. In both methodologies multi-family buildings with more than 3 floors make up of around 90% of the building stock, so the housing typology and the number of floors filters only around 10% of the residential building stock of the case study. This could probably be the case in other neighbourhoods of Barcelona which are mainly consisted of multi-family buildings of more than three floors. Through the study of the EPC U values per segment, there were some interesting results worth commenting. Multiple overlapping boxplots were found, suggesting similar range of U values across different segments. In addition, segments with boxplots with large boxes and whiskers, as well as two subgroups within their histograms were found, especially in façade U values in the period 1980 – 2007 in ERESEE and after 1980 in GTR methodology. This suggests that these segments have a higher degree of variability or dispersion. This can be explained by greater diversity in construction techniques applied during this period due to an explosion of technological solutions and materials in the building sector. Those observations raise questions about both the significance of the difference in the thermal transmittance of the segments in the first case, and the insufficiency of the segmentation to explain the variability of the thermal transmittance in the second case. Comparing the U-Values assigned by the methodologies during the characterization step with the medians of the EPC database resulting segments, led to high deviations between the two values. These discrepancies lead to either overestimation or underestimation of thermal transmittance values for different building segments and periods. These deviations are significant and have implications for assessing the thermal performance of the building stock. As an example, in the GTR methodology façade U values are mostly underestimated, with deviations of up to 238% for multi-family buildings with less than three floors. On the contrary, the k-means algorithm found 10 optimal clusters (groups of dwellings) that successfully describe the combination of the façade and the openings U values of the case study. There was no obvious relationship between the produced clusters and the housing typology, the number of floors and the construction period, although clusters with higher U values and energy demand align with older buildings. They don’t necessarily have higher opening U values, suggesting window replacements without comprehensive energy renovations. This validates the hypothesis that traditional segmentation criteria alone may not fully explain the variation in U-values, on a district level, where territory specific data are needed. In summary, the lack of a straightforward relationship between the produced clusters and those variables emphasizes that a building's age and typology alone does not dictate its thermal performance characteristics. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 82 Annex 1: Results per GTR segment Segment A The U-values of the façade, have a minimum value of 0,16 and a maximum value of 2,76, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,16 1,69 2,26 2,03 2,38 2,76 In the graphs we can see the distribution of the variable, in comparison with the determined value by the GTR methodology, that is represented with the red line, and in this case is 1,9. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 2,77 3,99 4,91 4,68 5,50 5,7 In the graphs we can see the distribution of the variable, in comparison with the determined value by the GTR methodology, that is represented with the red line, and in this case is 5,70. Maria Karatsiompani MCTS | MISMEC 83 Segment C The U-values of the façade, have a minimum value of 0,16 and a maximum value of 2,76, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 1,52 1,69 2,17 1,06 2,38 2,38 In the graphs we can see the distribution of the variable, in comparison with the determined value by the GTR methodology, that is represented with the red line, and in this case is 1,3. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 2,41 4,47 4,03 4,85 5,64 5,7 In the graphs we can see the distribution of the variable, in comparison with the determined value by the GTR methodology, that is represented with the red line, and in this case is 5,70. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 84 Segment G The U-values of the façade, have a minimum value of 0,16 and a maximum value of 2,76, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,53 0,94 1,69 1,36 1,8 1,8 In the graphs we can see the distribution of the variable, in comparison with the determined value by the GTR methodology, that is represented with the red line, and in this case is 0,5. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 2,07 3,44 3,64 3,71 3,87 5,04 In the graphs we can see the distribution of the variable, in comparison with the determined value by the GTR methodology, that is represented with the red line, and in this case is 5,70. Maria Karatsiompani MCTS | MISMEC 85 Segment NA1 The U-values of the façade, have a minimum value of 0,16 and a maximum value of 2,76, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,29 1,69 1,88 1,92 2,38 2,56 In the graphs we can see the distribution of the variable. GTR does not provide any value for this segment, since it did not represent a sufficient number of buildings at the national level. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 2,12 3,98 4,97 4,74 5,7 5,7 In the graphs we can see the distribution of the variable. GTR does not provide any value for this segment, since it did not represent a sufficient number of buildings at the national level. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 86 Segment NA2 The U-values of the façade, have a minimum value of 0,16 and a maximum value of 2,76, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,40 1,69 1,78 1,90 2,38 3,13 In the graphs we can see the distribution of the variable. GTR does not provide any value for this segment, since it did not represent a sufficient number of buildings at the national level. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 2,12 4,02 5,00 4,82 5,7 5,7 In the graphs we can see the distribution of the variable. GTR does not provide any value for this segment, since it did not represent a sufficient number of buildings at the national level. Maria Karatsiompani MCTS | MISMEC 87 Segment H The U-values of the façade, have a minimum value of 0,16 and a maximum value of 2,76, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,15 0,60 0,73 1,07 1,69 3,13 In the graphs we can see the distribution of the variable, in comparison with the determined value by the GTR methodology, that is represented with the red line, and in this case is 0,5. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 2,13 3,44 3,78 3,76 3,78 5,7 In the graphs we can see the distribution of the variable, in comparison with the determined value by the GTR methodology, that is represented with the red line, and in this case is 5,70. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 88 Segment B The U-values of the façade, have a minimum value of 0,11 and a maximum value of 3,13, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,26 1,69 1,93 1,97 2,38 3,30 In the graphs we can see the distribution of the variable, in comparison with the determined value by the GTR methodology, that is represented with the red line, and in this case is 1,9. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 1,76 4,12 5,19 4,92 5,7 5,7 In the graphs we can see the distribution of the variable, in comparison with the determined value by the GTR methodology, that is represented with the red line, and in this case is 5,70. Maria Karatsiompani MCTS | MISMEC 89 Segment F The U-values of the façade, have a minimum value of 0,11 and a maximum value of 3,13, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,14 1,69 1,92 1,94 2,38 3,13 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 1,30. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 1,12 3,92 5,00 4,82 5,7 6,79 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 5,70. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 90 Segment J The U-values of the façade, have a minimum value of 0,11 and a maximum value of 3,13, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,11 0,63 0,81 1,13 1,69 3,13 In the graphs we can see the distribution of the variable, in comparison with the determined value by the GTR methodology, that is represented with the red line, and in this case is 0,5. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 1,10 3,44 3,78 3,91 4,14 5,70 In the graphs we can see the distribution of the variable, in comparison with the determined value by the GTR methodology, that is represented with the red line, and in this case is 5,70. Maria Karatsiompani MCTS | MISMEC 91 Annex 2: Results per ERESEE segment Uu <=40 The U-values of the façade, have a minimum value of 0,11 and a maximum value of 3,3, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,32 1,78 2,26 2,04 2,38 2,76 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 2,12. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 3,23 3,78 4,44 4,47 5,00 5,70 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 4,24. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 98 Cc 80 – 07 The U-values of the façade, have a minimum value of 0,11 and a maximum value of 3,3, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,15 0,63 0,99 1,22 1,80 3,13 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 1,50. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 2,13 3,46 3,78 3,84 3,78 5,70 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 4,69. Maria Karatsiompani MCTS | MISMEC 99 Cc 08 – 20 The U-values of the façade, have a minimum value of 0,11 and a maximum value of 3,3, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,30 0,60 0,65 0,76 0,73 2,33 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 0,95. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 2,35 3,43 3,60 3,57 3,78 5,70 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 4,40. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 100 Bb <=40 The U-values of the façade, have a minimum value of 0,11 and a maximum value of 3,3, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,31 1,69 2,05 2,01 2,38 2,76 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 1,94. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 2,18 3,78 4,9 4,68 5,49 5,7 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 4,24. Maria Karatsiompani MCTS | MISMEC 101 Bb 40 – 60 The U-values of the façade, have a minimum value of 0,11 and a maximum value of 3,3, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,26 1,69 1,90 1,96 2,38 3,3 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 1,81. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 1,76 4,18 5,25 4,95 5,7 5,7 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 4,24. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 102 Bb 60 – 80 The U-values of the façade, have a minimum value of 0,11 and a maximum value of 3,3, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,14 1,69 1,92 1,94 2,38 3,13 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 1,68. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 1,12 3,92 5,00 4,82 5,7 6,79 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 4,24. Maria Karatsiompani MCTS | MISMEC 103 Bb 80 – 07 The U-values of the façade, have a minimum value of 0,11 and a maximum value of 3,13, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,11 0,69 1,17 1,24 1,8 3,13 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 1,50. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 1,10 3,51 3,78 4,08 4,75 5,7 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 4,69. Identification of key variables and their statistical analysis for parameterization of the energy classification of buildings 104 Bb 08 – 20 The U-values of the façade, have a minimum value of 0,11 and a maximum value of 3,13, as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 0,14 0,54 0,73 0,79 0,73 3,13 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 0,95. The U-values of the windows, have a minimum value of 1,12 and a maximum value of 6,79 as seen in the following table: Min. 1st Qu. Median Mean 3rd Qu. Max 1,17 2,97 3,44 3,37 3,78 5,7 In the graphs we can see the distribution of the variable, in comparison with the determined value by the ERESEE methodology, that is represented with the red line, and in this case is 4,40.