Full text
Citation: Punset, M.; Brizuela, A.; Pérez-Pevida, E.; Herrero-Climent, M.; Manero, J.M.; Gil, J. Mechanical Characterization of Dental Prostheses Manufactured with PMMA– Graphene Composites. Materials 2022, 15, 5391. https://doi.org/10.3390/ ma15155391 Academic Editors: Paolo Cappare and Bongju Kim Received: 3 June 2022 Accepted: 2 August 2022 Published: 5 August 2022 Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. Copyright: © 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/). materials Article Mechanical Characterization of Dental Prostheses Manufactured with PMMA–Graphene Composites Miquel Punset 1,2,3 , Aritza Brizuela 4, Esteban Pérez-Pevida 4, Mariano Herrero-Climent 5, JoséMaria Manero 1,2 and Javier Gil 6,* 1Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Engineering, Universitat Politècnica de Catalunya (UPC), Av. Eduard Maristany 16, 08019 Barcelona, Spain 2Barcelona Research Center in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany 10-14, 08019 Barcelona, Spain 3UPC Innovation and Technology Center (CIT-UPC), Technical University of Catalonia (UPC), C. Jordi Girona 3-1, 08034 Barcelona, Spain 4Facultad de Odontología, Universidad Europea Miguel de Cervantes, C/del Padre Julio Chevalier 2., 47012 Valladolid, Spain 5Porto Dental Institute, 4150-518 Oporto, Portugal 6Bioengineering Institute of Technology, International University of Catalonia, Josep Trueta s/n., 08195 Barcelona, Spain *Correspondence: xavier[email protected] Abstract: The use of a PMMA composite with graphene is being commercialized for application as dental prostheses. The different proportions of fibers provide a wide range of colors that favors dental esthetics in prostheses. However, there are no studies that have explained the influence that graphene has on the mechanical properties. In this contribution, we studied the PMMA and PMMA material with graphene fibers (PMMA-G) in the form of discs as supplied for machining. The presence of graphene fibers has been studied by Raman spectroscopy and the Shore hardness and Vickers micro hardness were determined. Mechanical compression tests were carried out to obtain the values of maximum strength and Young’s modulus (E) and by means of pin-on-disc wear tests, the specific wear rate and the friction coefficients were determined following the established international standards. Finally, the samples were characterized by field emission scanning electron microscopy (FESEM) to characterize the graphene’s morphology inside the PMMA. The results showed the presence of graphene in PMMA and was estimated in an amount of 0.1027% by weight in G-PMMA. The Shore hardness and Vickers microhardness values did not show statistically significant differences. Differences were observed in the compression maximum strength (129.43 MPa for PMMA and 140.23 for PMMA-G) and E values (2.01 for PMMA and 2.89 GPa for PMMA-G) as well as in the lower wear rate for the G-PMMA samples (1.93 × 10 −7 for PMMA and 1.33 × 10 −7 mm 3 /N · m) with a p< 0.005. The coefficients of friction for PMMA-G decreased from 0.4032 for PMMA to 0.4001 for PMMA-G. From the results obtained, a slight content in graphene produced a significant improvement in the mechanical properties that could be observed in the prosthesis material. Therefore, we can state that the main attraction of this material for dental prosthesis is its esthetics. Keywords: dental materials; prosthetic materials; PMMA; graphene; composites; mechanical properties 1. Introduction The oral cavity is one of the most aggressive human biological environments due to the complex biological and microbiological and electrolyte variation medium, which itself is affected by many type of factors such as dental plaque, bacteria oral microbiota, gastric acid reflux, and the presence of saliva as well as by variations of temperature, oxygen, and pH [1–3] . From the bacteria oral microbiota point of view, as the main gateway to the human body, the oral cavity shows great diversity, with more than 770 microbial Materials 2022,15, 5391. https://doi.org/10.3390/ma15155391 https://www.mdpi.com/journal/materials
Materials 2022,15, 5391 2 of 18 species described [ 4 , 5 ], which can produce periodontitis and caries that are the main dental oral diseases that may lead to teeth loss [ 6 ]. In addition to the complex and variable biological conditions of the oral medium, dental materials applied in the oral cavity are exposed to extremely high mechanical loading forces [7]. In summary, these harsh factors produce the action of several degradation mechanisms including the wear, fatigue, fracture, oxidation, and corrosion of dental implant materials, among others, which can compromise the durability or lifespan of dental materials. Thanks to certain very useful properties such as good mechanical properties, low price, easy manipulation and repair, esthetically pleasing and high biocompatibility [ 8 – 12 ], its use has been progressively expanded and strengthened. In the dental field, the use of polymeric materials, especially PMMA, plays an important role in the manufacture of temporary oral prostheses, temporary and relieving splints, three-dimensional models, bone cements, facial prostheses, liners, obturators, temporary veneers and crowns, among other components [ 13 , 14 ]. Synthetic polymers have been widely used as both dental and denture materials for more than half a century, since they meet the prosthetic requirements with regard to the esthetic, mechanical properties, chemical stability, corrosion resistance, and biocompatibility to be used as a denture and dental materials [ 15 – 22 ]. In relation to the above-mentioned polymers, poly(methyl methacrylate) (PMMA) has been extensively used for over 80 years as a biomaterial in dental fields because it meets most of the criteria for an ideal dental and denture materials [ 10 , 22 – 25 ]. PMMA was first used as a denture material in 1937 [26]. However, PMMA has some weaknesses and/or drawbacks mainly related to its mechanical [ 8 ], fatigue [ 27 ], thermal [ 28 ], and biological properties [ 20 , 29 ]. Among the main limitations of this material for long-term use in dental applications, two fundamental aspects stand out: its mechanical properties and its propensity to bacterial infection [ 8 ]. From the point of view of the mechanical properties, the lack of hardness and toughness translates into poor wear resistance, which affects the durability of the components. Furthermore, a major drawback for their long-term is related to poor antimicrobial property, which can cause polymer deterioration as well as infection when in contact with tissues or when being implanted for restoration [ 8 , 9 , 20 , 29 , 30 ]. The PMMA denture polymer is highly susceptible to bacterial colonization by Candida albicans and other pathogens, leading to Candida-associated denture stomatitis, a complex condition with a multifactorial etiology [ 31 , 32 ]. This chronic inflammatory condition is common among prosthesis users, which is very difficult to treat due to incomplete disinfection of the acrylic surface and rapid microbial recolonization [ 33 – 35 ]. An improvement in the strength of denture resins and mechanical properties is necessary for the long-time behavior of this polymer. Several strategies have been applied in order to increase both the mechanical properties and biological behavior of PMMA polymer resins, almost all of which were based on the addition of inorganic fillers such as mesoporous silica nanoparticles (MSNs) [ 36 – 39 ], nano-sized graphene oxides (nGO) [ 16 , 39 – 41 ], titanium dioxide (TiO 2 ) [ 41 – 46 ], and carbon nanotubes (CNTs) [ 47 – 49 ]. In this latter regard, some researchers have reported an increase in the mechanical properties coupled with the development of bactericidal capacities as a result of nGO reinforcement [41]. A review of the existing published scientific literature reflects the growing interest in the use/incorporation of graphene as a reinforcing phase in PMMA-based materials for dental applications [ 50 – 52 ]. Graphene is highly likely as one of the materials with the highest potential applicability in the coming decades. Since its discovery in 2004 [ 53 ], the use of graphene has expanded greatly, involving a wide variety of different fields of research, ranging from electronic and optoelectronics to biomedical in 2008. In general, graphenebased materials can be divided into four main categories: single-layer and few-layered graphene as well as graphene oxide (GO) and reduced graphene oxide (rGO) [54,55]. The dental and dental-prosthetic sectors are fields of application in continuous evolution, continuously incorporating new materials and manufacturing methods into their production processes. However, the dental field is subject to, influenced, and restricted
Materials 2022,15, 5391 3 of 18 by esthetic, biological and biocompatibility criteria, which greatly restrict the number and type of potentially usable materials including graphene. However, the main objective of the researchers to reach a consensus on the introduction of graphene in PMMA prostheses revolves around finding the minimum concentration of graphene necessary to generate a minimal, but acceptable improvement in mechanical performance, in order to reduce the cost increase due to the high price of graphene, while reducing the risk of problems associated with esthetic criteria, the possible staining of surrounding tissues, and possible cytotoxic effects. In light of the above, the application of graphene-reinforced PMMA-based composites for the biomedical sector requires the correct balance between the desired increase in mechanical properties, compliance with esthetic criteria, and possible biological complications in the surrounding tissues. One strategy to solve these problems is the incorporation of nano-additives (nanofibers, nanospheres, nanosheets, or nanotubes) [ 9 , 10 , 56 , 57 ]. Carbon-based nanomaterials, especially graphene, have been demonstrated to have a bactericide effect [ 9 , 20 , 58 – 60 ]. Graphene is a single layer of sp2 hybridized carbon atoms in a honeycomb lattice characterized by excellent properties and feasibility [ 61 – 64 ]. Graphene features a unique combination of several outstanding properties, some of which are related to large specific surface area ( 2630 m2g−1 ), high thermal conductivity (5000 Wm −1 K −1 ), high intrinsic mobility (200,000 cm2v−1s−1), and Young’s modulus (Young’s modulus of Y ~ 1.0 TPa) [65–70]. From the point of view of biomedical applications, graphene offers several advantages such as its biocompatibility and biodegradability [ 8 ], strength [ 71 ], flexibility [ 72 ], antibacterial behavior [ 73 ], good differentiation of stem cells such as osteogenesis [ 74 ], and neurogenesis [75], among the most important. Many studies have been carried out on the dental applications of this PMMA composite with graphene, but there are practically no studies comparing the mechanical properties for dental prosthesis application [ 76 – 85 ]. The objective of this study was to determine the improvement in the PMMA when it is reinforced with graphene, especially in the compressive strength, microhardness, and wear resistance, which are the most important properties for prosthodontic applications. 2. Materials and Methods 2.1. Materials The samples analyzed in this study corresponded to the “G-CAM” discs (Nanographene, Murcia, Spain), which consists of a PMMA disc nano-reinforced with graphene for CAD/CAM milling (G-PMMA). The control samples were only PMMA as a control base material. Figure 1a shows the PMMA discs with graphene in different shades, from the first PMMA disc (white color) to the last one with more graphene, in which a more ochre color could be observed (Figure 1b). This color had the highest amount of graphene and is not manufactured with a higher graphene content because the color is outside the scales of dental esthetics, given that graphene is black. This is why we carried out studies with the disc with the highest graphene content, and one that was only PMMA. The obtention of the composite (PMMA and graphene) followed the method described by Aldoari et al. [86]. The materials used were: •Graphite powder with a purity higher 99.5% (Merck, Darmstadt, Germany); •Hydrazine hydrate (HH, 80%) (Loba Chemi. Pvt. Ltd., Mumbai, India); •Methyl methacrylate (MMA) (Acros Chemical Co., Loughborough, UK, 99%); • Benzoyl peroxide (BP, BDH Chemicals Ltd., East Yorkshire, UK) was used as an initiator; •Potassium permanganate (KMnO4, >99%) (Merck, Darmstadt, Germany); •Hydrogen peroxide (H2O2, 30%) (Merck Darmstadt, Germany).
Materials 2022,15, 5391 4 of 18 Materials 2022, 15, x FOR PEER REVIEW 5 of 19 Figure 1. (a). Color range of PMMA–graphene offered by the manufacturer. (b) Samples studied as G-PMMA. (c) Dental restoration with G-PMMA with excellent esthetic results. 2.2. Raman Spectroscopy Raman spectra were obtained using a confocal Raman microscope (inViaTM Qontor confocal Raman microscope, Renishaw Inc. Waltham, MA, USA) with a 532 nm excitation laser at 100% power and a 5× objective lens. All spectra were recorded in the range 100– 3500 cm−1 with an integration time of 45 s and 10 accumulations per spectrum. Nine measurements were performed, three measurements at three different points per sample to determine their compositional homogeneity. 2.3. Gel Permeation Chromatography (GPC) The molecular weight (Mn) and polydispersity index (PDI) was determined by gel permeation chromatography (GPC) using a liquid chromatographic pump (Shimadzu, model LC-8A, Tokyo, Japan) controlled by the LC Solution software (Shimadzu, Tokyo, Japan). The polymer was dissolved end eluted in 1,1,1,3,3,3-hexafluoroisopropanol (HFIP) containing CF3COONa (0.05 M). The flow rate was 1 mL/min, the injected volume of 20 mm, and the sample concentration of 6 mg/mL. A PL HFIPgel column (Agilent Technologies Deutschland GmbH, Boblingen, Germany) and a refractive index detector (Shimadzu, model RID-20A, Tokyo, Japan) were employed. The number and weight average molecular weights were determined using the PMMA standards purchased from Sigma Aldrich, St. Louis, MI, USA. 2.4. Shore Hardness (HSD) The shore surface hardness is determined from the elastic reaction of a material when a rounded diamond-tipped indenter is dropped on it. The hardness depends on the amount of energy absorbed by the test material during impact. For this test, the specifications indicated in UNE-EN ISO 868:2003-Plastics and ebonite were used. The hardness Shore-D (HSD) is then proportional to the hammer rebound height, according to Expression (1) [89] where K is the proportionality factor; H1 is the hammer drop height; H2 is the hammer rebound height. Figure 1. ( a ). Color range of PMMA–graphene offered by the manufacturer. ( b ) Samples studied as G-PMMA. (c) Dental restoration with G-PMMA with excellent esthetic results. Following the Hummers and Offeman procedure [ 87 ], we obtained the graphite oxide (GO) by the oxidation of graphite. A total of 3.5 g of graphite was introduced to 98% H 2 SO 4 (100 mL) under stirring. Then, 10 g of KMNO 4 was introduced, maintaining the temperature below20 ◦ C. The solution was stirred for 2 h at 35 ◦ C. Next, the solution was poured into 500 mL of deionized H 2 O and H 2 O 2 (ca. 20 mL of a 30% aqueous solution) in order to neutralize the excess permanganate turning the solution yellow. GO was separated using a porous glass filter and washed with HCl 10% in volume. After repeated washing of the resulting yellowish-brown cake with hot water, the GO was dried at 80 ◦C. The obtained GO (400 mg) was stirred and sonicated in deionized water (20 mL) until a homogeneous yellow dispersion was obtained. HH (400 µ L) was added to the solution and introduced in a microwave. The microwave (KenWood MW740, Sant Cugat del Vallés, Spain,) was operated at 900 W for 30 s cycles with stirring in order to complete the reaction (approx. 2 min) [ 88 ]. The yellow change to black color showed the completion of the reduction reaction to RGO. The RGO sheets were isolated using a centrifuge (Centurion Scientific Ltd., West Sussex, UK) working at 5000 rpm for 15 min and dried at 80 ◦C overnight. RGO [0.1 (wt./wt.%)] was introduced to the monomer (MMA), stirred, and sonicated for 60 min. The initiator (BP) (5.0 wt.%) was added and dissolved in the solution. Afterward, the solution was heated to 60 ◦ C to start the polymerization reaction using a shakingwater bath (GFL, Burgwedel, Germany). After the polymerization reaction (around 20 h), methanol was added to remove the MMA monomer. Then, the product was filtered and dried at 80 ◦C. Four hundred milligrams of the dried composite of GO-PMMA was dissolved in DMF, stirred, and sonicated for 1 h. Then, the composite was placed inside a microwave oven (Kenwood MW740, Sant Cugat del Vallés, Spain) following the addition of HH (400 µ L). Next, the composites were separated using a centrifuge (Centurion Scientific Ltd. West Sussex, UK) For comparison, the PMMA was prepared via a similar procedure in the absence of the RGO and GO.
Materials 2022,15, 5391 5 of 18 The test specimens were prepared using numerical control machining techniques using a WOJIE CNC 5-axis metal milling machine model VMC 650 (WOJIE, Shandong, China). Test specimens were machined in compliance with the specifications set by international standards ASTM D2240, ASTM D695-15, and ASTM G99-17, in order to respect the dimensions specified therein. Figure 1c shows a prosthesis fabricated with G-PMMA with the highest graphene content in which it offers very good dental esthetics. Prior to the compositional analysis and mechanical characterization, all of the samples (G-PMMA and PMMA) were subjected to a cleaning process with the following procedure: - Three washes with sodium lauryl sulfate 20% and water for 5 min in ultrasound; - Three washes in distilled water for 5 min in ultrasound; - Three washes in 96% ethanol for 5 min under ultrasound; - Drying with nitrogen N2(g) for 5 min. 2.2. Raman Spectroscopy Raman spectra were obtained using a confocal Raman microscope (inViaTM Qontor confocal Raman microscope, Renishaw Inc. Waltham, MA, USA) with a 532 nm excitation laser at 100% power and a 5 × objective lens. All spectra were recorded in the range 100–3500 cm−1 with an integration time of 45 s and 10 accumulations per spectrum. Nine measurements were performed, three measurements at three different points per sample to determine their compositional homogeneity. 2.3. Gel Permeation Chromatography (GPC) The molecular weight (Mn) and polydispersity index (PDI) was determined by gel permeation chromatography (GPC) using a liquid chromatographic pump (Shimadzu, model LC-8A, Tokyo, Japan) controlled by the LC Solution software (Shimadzu, Tokyo, Japan). The polymer was dissolved end eluted in 1,1,1,3,3,3-hexafluoroisopropanol (HFIP) containing CF3COONa (0.05 M). The flow rate was 1 mL/min, the injected volume of 20 mm, and the sample concentration of 6 mg/mL. A PL HFIPgel column (Agilent Technologies Deutschland GmbH, Boblingen, Germany) and a refractive index detector (Shimadzu, model RID-20A, Tokyo, Japan) were employed. The number and weight average molecular weights were determined using the PMMA standards purchased from Sigma Aldrich, St. Louis, MI, USA. 2.4. Shore Hardness (HSD) The shore surface hardness is determined from the elastic reaction of a material when a rounded diamond-tipped indenter is dropped on it. The hardness depends on the amount of energy absorbed by the test material during impact. For this test, the specifications indicated in UNE-EN ISO 868:2003-Plastics and ebonite were used. The hardness Shore-D (HSD) is then proportional to the hammer rebound height, according to Expression (1) [ 89 ] where K is the proportionality factor; H 1 is the hammer drop height; H 2 is the hammer rebound height. HSD =K·H1 H2 (1) Determination of the indentation hardness was undertaken by means of a hardness tester (Shore hardness) [ 1 ] using a BAXLO equipment model SHORE TYPE D-U (Barcelona, Spain). In this case, a type D Shore indenter was used, applying a load of 4 kg for 15 s, respecting a distance of 12 mm with respect to the external perimeter of the sample and between consecutive measuring points, as specified in the ASTM D2240 test standard. A total of 10 measurements were taken per sample. The BAXLO hardness tester used in this study has a sensitivity of 1 Shore-D unit, a measuring capacity ranging from 1 to 100 Shore units and a measuring standard of 60 Shore-D units. A total of five Shore-D hardness measurements were carried out on each of the 15 samples analyzed, observing a distance of 12 mm with respect to the external perimeter
Materials 2022,15, 5391 6 of 18 of the sample and between consecutive measuring points, as specified in the ASTM D2240 test standard. 2.5. Hardness by Vickers Indentation The determination of hardness was analyzed by using an Izasa Durascan G5 microhardness tester (Izasa Scientific, Madrid, Spain) equipped with a Vickers indenter, which consists of a diamond pyramid with a base angle of 136 ◦ . The hardness measurements were carried out under a constant load of 300 g applied for 15 s, making a total of six measurements for each of the two materials studied. The Vickers hardness number (HVN) in GPa can be expressed following Equation (2) . HVN as a function of the applied load (P) in N and the average of the diagonals of the indentation (d) in µ m [ 87 ]: The constant value, 1854.4, was obtained from the calculation of the contact area. HVN =1854.4 P/d2(2) 2.6. Compression Test Both the elastic modulus and the maximum fracture toughness were determined by means of a compression test carried out under the specifications indicated in ASTM D695-15 “Standard Test Method for Compressive Properties of Rigid Plastics” [ 3 ]. For this purpose, a Bionix 358 (MTS, Eden Prairie, MN, USA) servo-hydraulic mechanical testing machine was used at a constant speed of 200 mm/min. The maximum stress was analyzed using five specimens of G-PMMA material and five control specimens of PMMA, which had a diameter of 12 mm and a height of 25 m, as indicated in the standard used. The Young’s modulus was determined using five specimens of the G-PMMA and PMMA materials with a diameter of 12 mm and a height of 50 mm, as indicated in the standard. 2.7. Surface Wear (“Pin-on-Disc Test”) The ball-on-disc test consists of evaluating the wear resistance of a material by sliding a metal ball over a surface with a constant load, obtaining values for the coefficient of friction and wear rate. In this case, a CSEM tribometer (CSM Instruments, Peseux, Switzerland) was used following the specifications indicated in ASTM G99-17 “Standard test method for wear testing with a pin-on-disk apparatus” [ 2 ], using a stainless steel ball of 6 mm in diameter with a normal load of 20 N applied. The equipment used can be observed in Figure 2. The amount of material loss was evaluated by measuring the cross-sectional area of the wear tracks using a Taylor-Hobson profilometer (Talysurf Plus Roughness tester). The friction coefficient values were measured in real-time throughout the whole experiment. The friction coefficient values were measured in real-time throughout the whole experiment. The Ws (specific wear rate) value was determined by measuring the volume loss of material in the wear scar channel after the tests were performed, according to Expression (3) [ 88 ], where V is the total wear volume in wear channel after the sliding distance L under the normal contact load W. Ws =V/(W·L)(3) Tests were carried out with the immersion lubrication of the samples in Hank’s physiological medium at 37 ◦ C during a total travel distance of 500 m. All tests were performed at a constant linear pin speed of 10 cm/s with a turning radius of 4 mm. In all of the tests, a stainless steel spherical counter body pin with a diameter of 6 ± 0.001 mm, hardness of 62 HRC, and average surface roughness (Ra) of 0.02 µ m was used as a friction pair. This counter body has a Young’s modulus of 200 GPa and a Poisson’s ratio of 0.27. Three specimens were realized per each material.
Materials 2022,15, 5391 7 of 18 Materials 2022, 15, x FOR PEER REVIEW 7 of 19 experiment. The Ws (specific wear rate) value was determined by measuring the volume loss of material in the wear scar channel after the tests were performed, according to Expression (3) [88], where V is the total wear volume in wear channel after the sliding distance L under the normal contact load W. Ws = V/(W · L) (3) Tests were carried out with the immersion lubrication of the samples in Hank’s physiological medium at 37 °C during a total travel distance of 500 m. All tests were performed at a constant linear pin speed of 10 cm/s with a turning radius of 4 mm. In all of the tests, a stainless steel spherical counter body pin with a diameter of 6 ± 0.001 mm, hardness of 62 HRC, and average surface roughness (Ra) of 0.02 µm was used as a friction pair. This counter body has a Young’s modulus of 200 GPa and a Poisson’s ratio of 0.27. Three specimens were realized per each material. Figure 2. The pin-on-disc test setup used for the wear resistance study. 2.8. Field Emission Scanning Electron Microscopy (FESEM) A field emission scanning electron microscope FSEM model “JSM-7001F Scanning Microscope” (Jeol, Tokyo, Japan) using a potential of 5 KV and an approximate working distance of between 9 and 11 mm was used for the measurements. This was equipped with an EDS (energy-dispersive X-ray spectroscopy, OXFORD model Xmax20, Oxford, UK), which allows for the identification of the chemical composition by means of the acquisition of the characteristic X-ray emission of each chemical element. In order to ensure the correct electrical conductivity of the PMMA surface with graphene, the sample was previously coated with a nanometric platinum/palladium (Pt–Pd) film by PVD-sputtering (Wilmington, MA, USA) 2.9. Statistical Analysis Figure 2. The pin-on-disc test setup used for the wear resistance study. 2.8. Field Emission Scanning Electron Microscopy (FESEM) A field emission scanning electron microscope FSEM model “JSM-7001F Scanning Microscope” (Jeol, Tokyo, Japan) using a potential of 5 KV and an approximate working distance of between 9 and 11 mm was used for the measurements. This was equipped with an EDS (energy-dispersive X-ray spectroscopy, OXFORD model Xmax20, Oxford, UK), which allows for the identification of the chemical composition by means of the acquisition of the characteristic X-ray emission of each chemical element. In order to ensure the correct electrical conductivity of the PMMA surface with graphene, the sample was previously coated with a nanometric platinum/palladium (Pt–Pd) film by PVD-sputtering (Wilmington, MA, USA). 2.9. Statistical Analysis The measurements were analyzed with the Stata 14 package (StataCorp ® , College Station, San Antonio, TX, USA). Statistical values such as the averages and standard deviations were determined. 3. Results Molecular weight (Mn) and polydispersity index (PDI) were determined by GPC using a liquid chromatographic pump (Shimadzu, model LC-8A, Tokyo, Japan) controlled by the LC Solution software (Shimadzu, Tokyo, Japan). The polymer was dissolved end eluted in 1,1,1,3,3,3-hexafluoroisopropanol (HFIP) containing CF3COONa (0.05 M). All parameters were measured in duplicate. The results obtained through the GPC analysis are summarized in Table 1, expressing the results in the form of a range of values. From the molecular mass distributions, several average parameters were obtained such as the
Materials 2022,15, 5391 8 of 18 average molecular mass in number (Mn), the average molecular mass in weight (Mw), the polydispersity (PDI), and the average molecular mass (Mz). Table 1. Values obtained by GPC on the PMMA base. Mn [g·mol−1] Mw [g·mol−1] Mz [g·mol−1] Mz [g·mol−1] PDI [a.u] PMMA 51,029–54,175 104,175–107,231 240,674–251,413 663,145–698,799 1.979–2.041 The RAMAN fingerprint of the PMMA and G-PMMA materials can be observed in Figure 3a,b, respectively. Regarding the G-PMMA material, the graph presented in Figure 3b shows three Raman spectra corresponding to the three different surface points of the analysis of the same sample. In the literature, the characteristic peaks for graphene are identified by RAMAN around 1582–1587 ◦ and above 2688–2790 ◦ [ 6 , 19 ]. The analyses performed on the PMMA sample with graphene showed two peaks corresponding to these positions: a well-defined peak around 1585 ◦ and a softer peak around 2689 ◦ (peaks marked with arrows in Figure 3b). These two peaks appeared in the analyzed areas of the sample. The content of graphene estimated was 0.1027 wt%. The first step of the mechanical characterization of the materials under study consisted of the determination of hardness, which was carried out using two different methods (Shore-A and HVN), the results of which are shown graphically in Figure 4. The results of the determination of the Shore-D HSD hardness were for PMMA 81 ±4 Shore units and for G-PMMA 81 ± 4 Shore-D units. The statistical analysis of the hardness results did not show the existence of statistically significant differences between the two samples analyzed. The Vickers micro hardness results were 23.6 ± 1.1 HVN for PMMA and for G-PMMA 24.6 ± 0.7. Again, no statistically significant differences were observed in this measure of hardness. Non-statistically significant differences in both the Shore-A and Vickers hardness values were observed between the two groups of samples (p> 0.05). The results of hardness can be observed in Table 2. Table 2. The Shore-D and Vickers hardness values for the PMMA and G-PMMA samples. HSD HVN PMMA 81 ±3.8 23.6 ±1.1 G-PMMA 81 ±3.2 24.6 ±0.7 From the compression tests for the PMMA and G-PMMA were obtained the results of the elastic modulus and maximum strength to fracture. Both materials evaluated showed the typical fracture behavior of markedly brittle, without the presence of clear signs of plastic deformation regardless of being reinforced with graphene. These results can be observed in Table 3. The graphical representation of the parameters determined by the mechanical compression tests are shown in Figure 5in the form of bar graphs. Statistically significant differences in both the maximum compressive strength and elastic modulus were observed between the two groups of samples (p< 0.05). Table 3. The elastic modulus and maximum compression strength for the PMMA and G-PMMA samples. E (GPa) Fmax (MPa) PMMA 2.01 ±0.22 129.43 ±7.75 G-PMMA 2.89 ±0.35 140.23 ±3.69
Materials 2022,15, 5391 9 of 18 Materials 2022, 15, x FOR PEER REVIEW 9 of 19 Figure 3. The Raman spectra of the PMMA (a) and G-PMMA (b) materials tested. Figure 3. The Raman spectra of the PMMA (a) and G-PMMA (b) materials tested.
Materials 2022,15, 5391 16 of 18 36. Zhang, J.; Wu, R.; Fan, Y.; Liao, S.; Wang, Y.; Wen, Z.; Xu, X. Antibacterial dental composites with chlorhexidine and mesoporous silica. J. Dent. Res. 2014,93, 1283–1289. [CrossRef] [PubMed] 37. Jo, J.-K.; El-Fiqi, A.; Lee, J.-H.; Kim, D.-A.; Kim, H.-W.; Lee, H.-H. Rechargeable microbial anti-adhesive polymethyl methacrylate incorporating silver sulfadiazine-loaded mesoporous silica nanocarriers. Dent. Mater. 2017,33, e361–e372. [CrossRef] 38. Lee, J.-H.; El-Fiqi, A.; Jo, J.-K.; Kim, D.-A.; Kim, S.-C.; Jun, S.-K.; Kim, H.-W.; Lee, H.-H. Development of long-term antimicrobial poly(methyl methacrylate) by incorporating mesoporous silica nanocarriers. Dent. Mater. 2016 ,32, 1564–1574. [CrossRef] [PubMed] 39. Beyene, H.D.; Werkneh, A.A.; Bezabh, H.K.; Ambaye, T.G. Synthesis paradigm and applications of silver nanoparticles (AgNPs), a review. Sustainable Mater. Technol. 2017,13, 18–23. [CrossRef] 40. Roco, M.C.; Hersam, M.C.; Mirkin, C.A. Nanotechnology Research Directions for Societal Needs in 2020, Retrospective and Outlook, 1st ed.; Springer: Berlin/Heidelberg, Germany, 2011. [CrossRef] 41. An, Y.; Liu, B.; Yan, X.; Pet, J.; Liu, W. The experimental study on wear resistance of the denture base material reinforced with graphene oxide. Tribology 2013,33, 222–228. 42. Song, J.; Zhang, J.; Lin, C. Influence of graphene oxide on the tribological and electrical properties of PMMA composites. J. Nanomater. 2013,2013, 846102. [CrossRef] 43. Chen, X.; Mao, S.S. Titanium Dioxide Nanomaterials: Synthesis, Properties, Modifications, and Applications. Chem. Rev. 2007 , 107, 2891–2959. [CrossRef] 44. Tolou, N.B.; Fathi, M.H.; Monshi, A.; Mortazavi, V.S.; Shirani, F.; Sichani, M.M. The Effect of Adding TiO 2 Nanoparticles on Dental Amalgam Properties. Iran. J. Mater. Sci. Eng. 2013,10, 46–56. 45. Totu, E.E.; Nechifor, A.C.; Nechifor, G.; Aboul-Enein, H.Y.; Cristache, C.M. Poly (Methyl Methacrylate) with TiO 2 Nanoparticles Inclusion for Stereolitographic Complete Denture Manufacturing—The Future in Dental Care for Elderly Edentulous Patients. J. Dent. 2017,59, 68–77. [CrossRef] [PubMed] 46. El-Zaher, N.A.; Melegy, M.S.; Guirguis, O.W. Thermal and Structural Analyses of PMMA/TiO 2 Nanoparticles Composites. Nat. Sci. 2014,6, 859–870. [CrossRef] 47. Turagam, N.; Mudrakola, D.P. Effect of Micro-Additions of Carbon Nanotubes to Polymethylmethacrylate on Reduction in Polymerization Shrinkage. J. Prosthodont. 2012,22, 105–111. [CrossRef] 48. Devoret, M.H.; Dai, H. Polymethylmethacrylate augmented with carbon nanotubes. Chem. Mater. 2007,12, 1049–1063. 49. Kumar, S.; Doshi, H.; Srinivasarao, M.; O Park, J.; A Schiraldi, D. Fibers from polypropylene/nano carbon fiber composites. Polymer 2002,43, 1701–1703. [CrossRef] 50. Chen, J.; Peng, H.; Wang, X.; Shao, F.; Yuan, Z.; Han, H. Graphene oxide exhibits broad-spectrum antimicrobial activity against bacterial phytopathogens and fungal conidia by intertwining and membrane perturbation. Nanoscale 2014 ,6, 1879–1889. [CrossRef] 51. Morimune, S.; Nishino, T.; Goto, T. Ecological approach to graphene oxide reinforced poly (methyl methacrylate) nanocomposites. ACS Appl. Mater. Interfaces 2012,4, 3596–3601. [CrossRef] 52. Chen, H.; Wang, B.; Gao, D.; Guan, M.; Zheng, L.; Ouyang, H.; Chai, Z.; Zhao, Y.; Feng, W. Broad-spectrum antibacterial activity of carbon nanotubes to human gut bacteria. Small 2013,9, 2735–2746. [CrossRef] 53. Novoselov, K.S.; Geim, A.K.; Morozov, S.V.; Jiang, D.; Zhang, Y.; Dubonos, S.V.; Grigorieva, I.V.; Firsov, A.A. Electric Field Effect in Atomically Thin Carbon Films. Science 2004,306, 666–669. [CrossRef] 54. Bei, H.P.; Yang, Y.; Zhang, Q.; Tian, Y.; Luo, X.; Yang, M.; Zhao, X. GrapheneBased Nanocomposites for Neural Tissue Engineering. Molecules 2019,24, 658. [CrossRef] [PubMed] 55. Agustín-Panadero, R.; Solá-Ruíz, M.F.; Chust, C.; Ferreiroa, A. Fixed dental prostheses with vertical tooth preparations without finish lines: A report of two patients. J. Prosthet. Dent. 2016,115, 520–526. [CrossRef] [PubMed] 56. Wang, R.; Tao, J.; Yu, B.; Dai, L. Characterization of multiwalled carbon nanotube-polymethyl methacrylate composite resins as denture base materials. J. Prosthet. Dent. 2014,111, 318–326. [CrossRef] 57. Fernandez, M.; Mendez, J.A.; Vazquez, B.; Roman, S.; Ginebra, M.P.; Gil, F.J.; Manero, J.M.; Planell, J.A. Acrylic-phosphate glasses composites as self-curing controlled delivery systems of antibiotics. J. Mater. Sci. Mater Med. J. 2002,13, 1251–1257. 58. Padovani, G.C.; Feitosa, V.P.; Sauro, S.; Tay, F.R.; Durán, G.; Paula, A.J.; Durán, N. Advances in Dental Materials through Nanotechnology: Facts, Perspectives and Toxicological Aspects. Trends Biotechnol. 2015,33, 621–636. [CrossRef] 59. Kim, K.I.; Kim, D.A.; Patel, K.; Shin, U.S.; Kim, H.W.; Lee, J.H.; Lee, H.H. Carbon nanotube incorporation in PMMA to prevent microbial adhesion. Sci. Rep. 2019,9, 10. [CrossRef] 60. Vazquez, B.; Ginebra, M.P.; Gil, F.J.; Planell, J.A.; San Roman, J. Acrylic bone cements modified with beta-TCP particles encapsulated with poly(ethylene Glycol). Biomaterials 2005,26, 4309–4316. [CrossRef] 61. Banerjee, A.N. Graphene and its derivatives as biomedical materials: Future prospects and challenges. Interface Focus 2018 , 8, 20170056. [CrossRef] 62. Ferrari, A.C.; Meyer, J.C.; Scardaci, V.; Casiraghi, C.; Lazzeri, M.; Mauri, F.; Piscanec, S.; Jiang, D.; Novoselov, K.S.; Roth, S.; et al. Raman spectrum of graphene and graphene layers. Phys. Rev. Lett. 2006,97, 187401. [CrossRef] 63. Zhen, Z.; Zhu, H. 1—Structure and Properties of Graphene; Hongwei, Z., Zhiping, X., Dan, X., Ying, F., Eds.; Academic Press: Cambridge, MA, USA, 2018; pp. 1–12. ISBN 9780128126516. [CrossRef] 64. Foo, M.E.; Gopinath, S.C. Feasibility of graphene in biomedical applications. Biomed. Pharmacother. 2017 ,94, 354–361. [CrossRef]
Materials 2022,15, 5391 17 of 18 65. Zhu, Y.; Murali, S.; Cai, W.; Li, X.; Suk, J.W.; Potts, J.R.; Ruoff, R.S. Graphene and Graphene Oxide: Synthesis, Properties, and Applications. Adv. Mater. 2010,22, 3906–3924. [CrossRef] [PubMed] 66. Geim, A.K.; Novoselov, K.S. The rise of graphene. Nanosci. Technol. 2009,10, 11–19. [CrossRef] 67. Bolotin, K.; Sikes, K.; Jiang, Z.; Klima, M.; Fudenberg, G.; Hone, J.; Kim, P.; Stormer, H. Stormer, Ultrahigh electron mobility in suspended graphene. Solid State Commun. 2008,146, 351–355. [CrossRef] 68. Morozov, S.V.; Novoselov, K.S.; Katsnelson, M.I.; Schedin, F.; Elias, D.C.; Jaszczak, J.A.; Geim, A.K. Giant Intrinsic Carrier Mobilities in Graphene and Its Bilayer. Phys. Rev. Lett. 2008,100, 016602. [CrossRef] [PubMed] 69. Suk, J.W.; Piner, R.D.; An, J.; Ruoff, R.S. Mechanical properties of monolayer graphene oxide. ACS Nano 2010 ,4, 6557–6564. [CrossRef] 70. Balandin, A.A.; Ghosh, S.; Bao, W.; Calizo, I.; Teweldebrhan, D.; Miao, F.; Lau, C.N. Superior Thermal Conductivity of Single-Layer Graphene. Nano Letters 2008,8, 902–907. [CrossRef] 71. Dong, R.; Liu, L. Preparation and properties of acrylic resin coating modified by functional graphene oxide. Appl. Surf. Sci. 2016 , 368, 378–387. [CrossRef] 72. Watson, G.; Starost, K.; Bari, P.; Faisal, N.; Mishra, S.; Njuguna, J. Tensile and flexural properties of hybrid graphene oxide/epoxy carbon fibre reinforced composites. IOP Conf. Ser. Mater. Sci. Eng. 2017,195, 012009. [CrossRef] 73. Hu, W.; Peng, C.; Luo, W.; Lv, M.; Li, X.; Li, D. Graphene-based antibacterial paper. ACS Nano 2010,4, 4317–4323. [CrossRef] 74. Kim, J.; Kim, Y.R.; Kim, Y.; Lim, K.T.; Seonwoo, H.; Park, S. Graphene-incorporated chitosan substrata for adhesion and differentiation of human mesenchymal stem cells. J. Mater. Chem. B 2013,1, 933–938. [CrossRef] 75. Park, S.Y.; Park, J.; Sim, S.H.; Sung, M.G.; Kim, K.S.; Hong, B.H. Enhanced differentiation of human neural stem cells into neurons on graphene. Adv. Mater. 2011,23, 263–267. [CrossRef] [PubMed] 76. Novoselov, K.S.; Fal, V.; Colombo, L.; Gellert, P.; Schwab, M.; Kim, K. A roadmap for graphene. Nature 2012 ,490, 192–200. [CrossRef] [PubMed] 77. Xie, Y.; Li, H.; Ding, C.; Zheng, X.; Li, K. Effects of graphene plates’ adoption on the microstructure, mechanical properties, and in vivo biocompatibility of calcium silicate coating. Int. J. Nanomed. 2015,10, 3855. [CrossRef] 78. Poot, M.; van der Zant, H.S. Nanomechanical properties of fewlayer graphene membranes. Appl. Phys. Lett. 2008 ,92, 063111. [CrossRef] 79. Harrison, B.S.; Atala, A. Carbon nanotube applications for tissue engineering. Biomaterials 2007,28, 344–353. [CrossRef] 80. Park, C.H.; Park, S.; Lee, D.; Choi, K.S.; Lim, H.P.; Kim, J. Graphene as enabling strategy for dental implant and tissue regeneration. Tissue Eng. Regen. Med. 2017,14, 481–493. [CrossRef] 81. Segerstrom, S.; Ruyter, I.E. Adhesion properties in systems of laminated pigmented polymers, carbon-graphite fiber composite framework and titanium surfaces in implant suprastructures. Dent. Mater. 2009,25, 1169–1177. [CrossRef] 82. Santos, C.M.; Mangadlao, J.; Ahmed, F.; Leon, A.; Advincula, R.C.; Rodrigues, D.F. Graphene nanocomposite for biomedical applications: Fabrication, antimicrobial and cytotoxic investigations. Nanotechnology 2012,23, 395101. [CrossRef] 83. Sun, X.; Liu, Z.; Welsher, K.; Robinson, J.T.; Goodwin, A.; Zaric, S. Nano-graphene oxide for cellular imaging and drug delivery. Nano Res. 2008,1, 203–212. [CrossRef] 84. Feng, L.; Zhang, S.; Liu, Z. Graphene based gene transfection. Nanoscale 2011,3, 1252–1257. [CrossRef] 85. Lee, W.C.; Lim, C.H.Y.; Shi, H.; Tang, L.A.; Wang, Y.; Lim, C.T. Origin of enhanced stem cell growth and differentiation on graphene and graphene oxide. ACS Nano 2011,5, 7334–7341. [CrossRef] [PubMed] 86. Hassan, H.; Abdelsayed, V.; Khder, A.; AbouZeid, K.; Terner, J.; El-Shall, M.; Al-Resayes, S.; El-Azhary, A. Microwave synthesis of graphene sheets supporting metal nanocrystals in aqueous and organic media. J. Mater. Chem. 2009,19, 3832–3837. [CrossRef] 87. Hummers, W.S.; Offeman, R.E. Preparation of graphitic oxide. J. Am. Chem. Soc. 1958,80, 1339. [CrossRef] 88. Aldosari, M.A.; Othman, A.A.; Alsharaeh, E.H. Synthesis and Characterization of the In Situ Bulk Polymerization of PMMA Containing Graphene Sheets Using Microwave Irradiation. Molecules 2013,18, 3152–3167. [CrossRef] 89. Aslanyan, E.; Doynikov, A.; Pivovarov, V. VNIIFTRI, Moscow, Russia. In Metrological characteristics of the national shore d scale hardness standard. In Proceedings of the XVII IMEKO World Congress, Dubrovnik, Croatia, 22–27 June 2003. 90. He, S.; Song, B.; Li, D.; Zhu, C.; Qi, W.; Wen, Y. A graphene nanoprobe for rapid, sensitive, and multicolor fluorescent DNA analysis. Adv Funct. Mater. 2010,20, 453–459. [CrossRef] 91. Chicot, D.; Mercier, D.; Roudet, F.; Silva, K.; Staia, M.; Lesage, J. Comparison of instrumented Knoop and Vickers hardness measurements on various soft materials and hard ceramics. J. Eur. Ceram. Soc. 2007,27, 1905–1911. [CrossRef] 92. Kato, K. Classification of wear mechanisms/models. Proceedings of the Institution of Mechanical Engineers, Part J. J. Eng. Tribol. 2002,216, 349–355. [CrossRef] 93. Fedel, M. Hemocompatibility of Carbon Nanostructures. J. Carbon Res. 2020,6, 12. [CrossRef] 94. Brash, J.L. Studies of protein adsorption relevant to blood compatible materials. In Modern Aspects of Protein Adsorption on Biomaterials; Springer: Dordrecht, The Netherlands, 1991; pp. 39–47. ISBN 978-94-011-3752-2. 95. Pascual, B.; Vázquez, B.; Gurruchaga, M.; Goñi, I.; Ginebra, M.P.; Gil, F.J.; Planell, J.A.; Levenfeld, B.; San Román, J. New aspects of the effect of size and size distribution on the setting parameters and mechanical properties of acrylic bone cements. Biomaterials 1996,17, 509–516. [CrossRef] [PubMed] 96. Pascual, B.; Gurruchaga, M.; Ginebra, M.P.; Gil, F.J.; Planell, J.A.; Goñi, I. Influence of the modification of P/L ratio on a new formulation of acrylic bone cement. Biomaterials 1999,20, 465–474. [CrossRef]
Materials 2022,15, 5391 18 of 18 97. Vazquez, B.; Ginebra, M.P.; Gil, F.J.; Planell, J.A.; Bravo, A.; San Roman, J. Radiopaque acrylic cements prepared with a new acrilic derivate of iodo-quinoline. Biomaterials 1999,20, 2047–2053. [CrossRef] 98. Manero, J.M.; Gil, F.J.; Padros, E.; Planell, J.A. Applications of enviromental sacnning electron microscopy (ESEM) in biomaterials field. Microsc. Res. Tech. 2003,61, 469–480. [CrossRef] [PubMed] 99. Alamgir, M.; Nayak, G.C.; Mallick, A.; Tiwari, S.K.; Mondal, S.; Gupta, M. Processing of PMMA nanocomposites containing biocompatible GO and TiO2nanoparticles. Mater. Manuf. Process. 2018,33, 1291–1298. [CrossRef] 100. Khan, A.A.; Mirza, E.H.; Mohamed, B.A.; Alharthi, N.H.; Abdo, H.S.; Javed, R.; Alhur, R.S.; Vall itt u, P.K. Physical mechanical, chemical and thermal properties of nanoscale graphene oxide-poly methylmethacrylate composites. J. Compos. Mater. 2018 ,52, 2803–2813. [CrossRef] 101. Ramanathan, T.; Abdala, A.A.; Stankovich, S.; Dikin, D.A.; Herrera-Alonso, M.; Piner, R.D.; Adamson, D.H.; Schniepp, H.C.; Chen, X.; Ruoff, R.S.; et al. Functionalized graphene sheets for polymer nanocomposites. Nat. Nanotech. 2008 ,3, 327–331. [CrossRef] 102. Wang, W.; Liao, S.; Zhu, Y.; Liu, M.; Zhao, Q.; Fu, Y. Recent applications of nanomaterials in prosthodontics. J. Nanomater. 2015 , 3, 3. [CrossRef] 103. Tecco, S.; Grusovin, M.G.; Sciara, S.; Bova, F.; Pantaleo, G.; Capparé, P. The association between three attitude-related indexes of oral hygiene and secondary implant failures: A retrospective longitudinal study. Int. J. Dent. Hyg. 2018,16, 372–379. [CrossRef] 104. Cappare, P.; Ferrini, F.; Mariani, G.; Nagni, M.; Cattoni, F. Implant rehabilitation of edentulous jaws with predominantly monolithic zirconia compared to metal-acrylic prostheses: A 2-year retrospective clinical study. J. Biol. Regul. Homeost. Agents 2021,35 (Suppl. 1), 99–112. [CrossRef] 105. Manazza, F.; La Rocca, S.; Nagni, M.; Chirico, L.; Cattoni, F. A simplified digital workflow for the prosthetic finishing of implant rehabilitations: A case report. J. Biol. Regul. Homeost. Agents 2021,35 (Suppl. 1), 87–97. [CrossRef] 106. Cattoni, F.; Chirico, L.; Cantile, N.; Merlone, A. Traditional prosthetic workflow for implant rehabilitations with a reduced number of fixtures: Proposal of a protocol. J. Biol. Regul. Homeost. Agents 2021,35 (Suppl. 1), 31–40. [CrossRef] 107. Joda, T.; Zarone, F.; Ferrari, M. The complete digital workflow in fixed prosthodontics: A systematic review. BMC Oral Health 2017,17, 124. [CrossRef] [PubMed] 108. Cattoni, F.; Merlone, A.; Broggi, R.; Manacorda, M.; Vinci, R. Computer-assisted prosthetic planning and implant design with integrated digital bite registration: A treatment protocol. J. Biol. Regul. Homeost. Agents 2021 ,35 (Suppl. 1), 11–29. [CrossRef] [PubMed]