Measurement of the 24,25,26Mg(n, gamma) reaction cross-section at n-TOF
Abstract
We have measured the neutron-induced capture cross-section of the importants-process isotopesof magnesium. The measurement has been performed at the neutron time-of-flight facility n_TOFat CERN. From a preliminary analysis of this new set of capture data we find that our resultsseem to be significantly lower than previous data and evaluations. We have also investigated thecontribution of the direct capture component to the Maxwellian-averaged capture cross section
Full text
PoS(NIC XI)194 Measurement of the 24,25,26Mg(n,γ) reaction cross-section at n_TOF C. Massimi∗1), S. Andriamonje2), J. Andrzejewski3), L. Audouin4), V. Bécares5), F. Beˇ cvᡠr6), F. Belloni7), B. Berthier4), E. Berthoumieux8), M. Brugger2), M. Calviani2), F. Calviño9), D. Cano-Ott5), C. Carrapiço10), F. Cerutti2), E. Chiaveri2), M. Chin2), N. Colonna11), G. Cortés9), M.A. Cortés-Giraldo12), I. Dillmann13), C. Domingo-Pardo14), I. Duran15), M. Fernández-Ordóñez5), A. Ferrari2), K. Fraval8), S. Ganesan16), G. Giubrone17), M.B. Gómez-Hornillos9), I.F. Gonçalves10), E. González-Romero5), F. Gramegna18), C. Guerrero5), F. Gunsing8), S. Harrisopulos19), M. Heil14), K. Ioannides20), E. Jericha21), Y. Kadi2), F. Käppeler22), D. Karadimos20), M. Krtiˇ cka6), E. Lebbos2), C. Lederer23), H. Leeb21), R. Losito2), M. Lozano12), J. Marganiec3), S. Marrone11), T. Martinez5), P.F. Mastinu18), M. Meaze11), E. Mendoza5), A. Mengoni24), P.M. Milazzo7), C. Paradela15), A. Pavlik23), J. Perkowski3), R. Plag14), J. Praena12), J.M. Quesada12), T. Rauscher25), R. Reifarth14), F. Roman2,26), C. Rubbia2,27), R. Sarmento10), G. Tagliente11), J.L. Tain17), D. Tarrío15), L. Tassan-Got4), L. Tlustos2), G. Vannini1), V. Variale11), P. Vaz10), A. Ventura24), V. Vlachoudis2), R. Vlastou28), A. Wallner23), C. Weiß21) c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence. http://pos.sissa.it/
PoS(NIC XI)194 1) Dipartimento di Fisica, Università di Bologna, and Sezione INFN di Bologna, Italy 2) European Organization for Nuclear Research (CERN), Geneva, Switzerland 3) Uniwersytet Łódzki, Lodz, Poland 4) Centre National de la Recherche Scientifique/IN2P3 - IPN, Orsay, France 5) Centro de Investigaciones Energeticas Medioambientales y Technologicas (CIEMAT), Madrid, Spain 6) Charles University, Prague, Czech Republic 7) Istituto Nazionale di Fisica Nucleare, Trieste, Italy 8) Commissariat à l’Énergie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette, France 9) Universitat Politecnica de Catalunya, Barcelona, Spain 10) Instituto Tecnológico e Nuclear (ITN), Lisbon, Portugal 11) Istituto Nazionale di Fisica Nucleare, Bari, Italy 12) Universidad de Sevilla, Spain 13) Physik Department E12 and Excellence Cluster Universe, Technische Universität München, Garching, Germany 14) GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany 15) Universidade de Santiago de Compostela, Spain 16) Bhabha Atomic Research Centre (BARC), Mumbai, India 17) Instituto de Física Corpuscular, CSIC-Universidad de Valencia, Spain 18) Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, Italy 19) National Centre of Scientific Research (NCSR), Demokritos, Greece 20) University of Ioannina, Greece 21) Atominstitut, Technische Universität Wien, Austria 22) Karlsruhe Institute of Technology, Campus Nord, Institut für Kernphysik, Karlsruhe, Germany 23) Fakultät für Physik, Universität Wien, Austria 24) Agenzia nazionale per le nuove tecnologie, l’energia e lo sviluppo economico sostenibile (ENEA), Bologna, Italy 25) Department of Physics and Astronomy - University of Basel, Basel, Switzerland 26) Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH, Bucharest - Magurele, Romania 27) Laboratori Nazionali del Gran Sasso dell’INFN, Assergi (AQ),Italy 28) National Technical University of Athens (NTUA), Greece E-mail: [email protected] We have measured the neutron-induced capture cross-section of the important s-process isotopes of magnesium. The measurement has been performed at the neutron time-of-flight facility n_TOF at CERN. From a preliminary analysis of this new set of capture data we find that our results seem to be significantly lower than previous data and evaluations. We have also investigated the contribution of the direct capture component to the Maxwellian-averaged capture cross section. 11th Symposium on Nuclei in the Cosmos, NIC XI July 19-23, 2010 Heidelberg, Germany ∗Speaker. c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence.
PoS(NIC XI)194 Measurement of the 24,25,26Mg(n,γ) reaction cross-section at n_TOF C. Massimi 1. Introduction and physical motivations The slow neutron-capture process (s-process) [1,2] in stars is responsible for the origin of about half of the elemental abundances beyond iron that we observe today. Most of the s-process isotopes between iron and strontium (60 <A<90) are produced in massive stars (M>8Msun) where the 22Ne(α,n)25Mg reaction is the main neutron source. Beyond strontium, the s-process abundances from Zr to Biare essentially produced in low mass Asymptotic Giant Branch (AGB) stars in the mass range 1.2Msun <M<3Msun, where most of the neutrons are provided by the 13C(α,n)16O reaction and to minor part by the partial activation of the 22Ne(α,n)25Mg reaction. While 56Fe represents the basic s-process seed for the production of the heavier isotopes, 25Mg acts as an important neutron poison and affects, therefore, the neutron balance of the sprocess. Accordingly, the 25Mg(n,γ)26Mg cross section is required with good accuracy for a quantitative treatment of s-process nucleosynthesis. 1.1 Status of Mg data libraries Existing evaluations of the Mg cross sections are presently based on the JENDL3.3 library [3]. In this evaluation the resonance parameters in the resolved resonance region were adopted from the compilation of Mughabghab [4], and negative resonances were added to reproduce the recommended thermal cross sections in Ref. [4]. The recommended thermal values are close to the experimental results of Walkiewicz et. al [5], but do not consider recent data of Koehler [6]. In this work previous measurements [8,9] were reconsidered in a combined R-matrix analysis, by which the spin of several levels could be determined. Moreover, it was shown in Ref. [6] that complementary information from Ref. [10] is important for obtaining parity assignments of the nuclear levels populated in neutron reactions on 25Mg+n. Because the differences between JENDL3.3 and Ref. [6] cannot be explained by the different spin assignments for the most relevant resonances alone, a new capture measurement was performed in order to obtain improved information for an update of the (n,γ) cross sections of 24,25,26Mg. 2. The experiment at CERN n_TOF The neutron time-of-flight facility n_TOF at CERN provides a white, pulsed neutron spectrum. The description given here refers to status during phase I of the facility (2001 - 2004) when the present data were taken (for a discussion of recent improvements see Ref. [7]). Neutrons were produced by spallation of protons with 20-GeV/c from the CERN proton synchrotron in a massive (80×80×60 cm3) lead block surrounded by 5.8 cm of cooling water, which acted also as a neutron moderator. The energy dependence of the neutron spectrum showed a 1/Eisolethargic behavior over the energy range of interest, i.e. between 1 eV and 1 MeV. The proton pulses are characterized by a high intensity of 7×1012 protons per bunch and a short pulse width of 6 ns FWHM, resulting in a high-resolution, high-intensity neutron beam. The evacuated neutron flight path to the experimental area at about 185 m from the spallation target is equipped with two collimators for reducing the beam from the initial diameter of 80 cm 2
PoS(NIC XI)194 Measurement of the 24,25,26Mg(n,γ) reaction cross-section at n_TOF C. Massimi to 1.8 cm at the sample position. The background in the experimental area is strongly reduced by a sweeping magnet and massive Fe and concrete walls along the flight path (for details see Refs. [11,12]). The time between proton pulses is at least 2.4 s, long enough to prevent neutron overlap between consecutive bunches. An array of two C6D6liquid scintillators has been used as in the capture experiment. The detectors are placed perpendicular to the beam direction but shifted 9 cm upstream of the beam for reducing the effect of in-beam γrays. Because the capture cross sections of the Mg isotopes are orders of magnitude smaller than the elastic scattering cross section, we preferred the total energy detection method [13] in combination with the Pulse Height Weighting Technique (PHWT), because of the small capture detector to be used (volume ≈one liter). Background due to samplescattered neutrons in the detector was strongly reduced by means of in-house developed C6D6 detectors based on a low mass carbon fiber design [14]. The neutron flux at the sample position at 185 m, which is required for determining the capture cross-section, has been measured with a well calibrated 235U loaded parallel plate ionization chamber from Physikalisch-Technische Bundesanstalt at Braunschweig [15]. During the actual runs, the flux was measured and with a 6Li neutron monitor [16]. The characteristics of the samples, which were disks 22 mm in diameter, are listed in Table 1. The enriched 25Mg and 26Mg samples consisted of magnesium-oxyde powder and were sealed in a very thin aluminum canning with a total mass of only 350 mg. The specified impurities of the enriched samples included traces of Be, Sb, Fe, Al, Sn, Mn, Cu, Ca, Mo, Ni, Ag, and Pb. Sample Isotopic abundance (%) Total Thickness Chemical ID 24Mg 25Mg 26Mg mass (g) (cm) (Atoms/barna) form natMg 78.7 10.13 11.17 5.2393 0.7930 0.03415 metal 25Mg 3.05 95.750 1.20 3.1924 0.2294 0.01234 oxyde 26Mg 2.46 1.28 96.26 3.2301 0.2266 0.01219 oxyde aAreal density of the most abundant isotope. Table 1: Sample characteristics. 3. Data analysis The light output of the C6D6detectors is calibrated by means of mono-energetic γ-ray sources (137Cs, 60C0, Pu/C). The dead time of the detector is determined from the time-difference distribution of consecutive signals in each detector. From this distribution a 20-ns dead time was obtained for the actual capture setup. To avoid dead time fluctuations, a fixed value of 30 ns was considered off-line for the digitized data. The corresponding dead time correction is lower than 1% up to 750 keV neutron energy. The determination of the capture yield (that is the probability of a capture reaction) relies on the PHWT. This technique requires a mathematical manipulation of the response function of the detection system [13], the so-called weighting function (WF). The WF is calculated by means of Monte Carlo simulations by considering the geometry and the particular design of the experimental 3
PoS(NIC XI)194 Measurement of the 24,25,26Mg(n,γ) reaction cross-section at n_TOF C. Massimi Figure 1: The 25Mg(n,γ) yield together with the background contribution from the aluminum canning. setup used. The capture yield Y=NCW−B ϕis obtained as a function of TOF from CW, the number of weighted counts (counts multiplied by their weighting factors), corrected for the background B, and the neutron fluence ϕ. The fact that the sample is smaller than the neutron beam is considered by the normalization factor N. This normalization was determined with the saturated resonance method using the 4.9-eV resonance in gold [17]. The capture yield of 25Mg, which represents the main result of this experiment, is plotted in Fig. 1together with the background contribution. The calculated capture yield is related to the capture cross-section σγby the expression Y= (1−exp(−nσtot))×σγ σtot , where nis the target thickness and σtot the total cross-section. The capture yield was analyzed with the R-matrix code SAMMY [18] for determining the resonance parameters. Experimental effects, that is multiple neutron scattering in the sample, neutron self-shielding, and experimental resolution, are properly taken into account within the SAMMY code. Preliminary resonance analyses have revealed discrepancies compared to previous evaluations. An example obtained by the simultaneous analysis of capture data from the present measurement and of transmission data from Ref. [9] is given in Fig. 2. Because the resonance shown in Fig. 2contributes about 30% to the MACS at 30 keV, the final MACS is expected to be smaller than reported so far [6]. In addition to the resonant component, the contribution from the direct radiative capture (DRC) mechanism has been calculated. For all three isotopes, the most important (electric dipole) transitions are due to incident p-wave neutrons captured into bound levels with strong single-particle component in the sd shell. The resulting cross section for DRC is sensitive in this particular case to the strength of the neutron-nucleus mean field (optical) potential. Using “standard” parameters, a contribution to the MACS at kT=30 keV of less than 1 mb for each of the Mg isotope has been found. However, the presence of the single-particle 2p state close to the neutron emission threshold complicates the standard treatment of the DRC calculation in this case. Therefore, the issue still needs to be investigated in order to conclude if the DRC mechanism has a significant impact on the MACSs of the Mg isotopes. 4. Conclusions With the present (n,γ) measurement the cross-section data on stable Mg isotopes can be im4
PoS(NIC XI)194 Measurement of the 24,25,26Mg(n,γ) reaction cross-section at n_TOF C. Massimi Figure 2: Simultaneous resonance shape analyses on capture and transmission data for the first s-wave resonance in the 25Mg(n,γ) cross section. proved. From preliminary analyses we find that the MACS of 25Mg is lower than previously reported. The expected changes of the stellar (n,γ) rates for the Mg isotopes will have a significant impact on the neutron balance of the s−process. References [1] G Wallerstein et al., Rev. Mod. Phys. 69, 995 (1997). [2] E. M. Burbidge, G. R. Burbidge, W. A. Fowler, and F. Hoyle, Rev. Mod. Phys. 29, 547 (1957). [3] K. Shibata et. al, J. Nucl. Sci. Technol. 39, 1125 (2002). [4] S. F. Mughabghab and D. I. Garber, Neutron cross sections, volume 1, (1984). [5] T. A. Walkiewicz, S. Raman, E. .T. Jurney, J. W. Starner and J. E. Lynn, Phys. Rev. C 45, 1597-1608 (1992). [6] P. E. Koehler, Phys. Rev. C 66, 055805 (2002). [7] E. Chiaveri for the n_TOF Collaboration, Int. Conf. on Nuclear Data for Science and Technology, ND2010 (in preparation). [8] U. N. Singh, H. I. Liou, J. Rainwater, G. Hacken and J. B. Garg, Phys. Rev. C 10, 2150-2152 (1974). [9] H. Weigmann, R. L. Macklin and J. A. Harvey, Phys. Rev. C 14, 1328-1335 (1976). [10] B. L. Berman, R. L. Van Hemert and C. D. Bowman, Phys. Rev. Lett 23, 386-389 (1969). [11] U. Abbondanno et al.,CERN n_TOF facility: Performance report, CERN-SL-2002-053 ECT (2003). [12] F. Gunsing et al. (The n_TOF Collaboration), Nucl. Instrum. and Methods B 261, 925-929 (2007). [13] A. Borella, G. Aerts, F. Gunsing, M. Moxon, P. Schillebeeckx and R. Wynants, Nucl. Instrum. and Methods A 577, 626-640 (2007). [14] R. Plag et al., Nucl. Instrum. and Methods A 496 425-436 (2003). [15] C. Borcea et al., Nucl. Instrum. and Methods A 513, 524-537, (2003). [16] S. Marrone et al., Nucl. Instrum. and Methods A 517, 389-398, (2003). [17] R. L. Macklin, J. Halperin and R. R. Winters, Nucl. Instrum. and Methods 164, 213-214 (1979). [18] N. M. Larson, Oak Ridge National Laboratory Report No. ORNL/TM-9179/R7. 5