Full text
Doctoral Thesis Doctoral Thesis “EXTENSION OF FINITE-CONTROL SET MODEL-BASED PREDICTIVE CONTROL TECHNIQUES TO FAULT-TOLERANT MULTIPHASE DRIVES: ANALYSIS AND CONTRIBUTIONS” PhD Candidate: Hugo M. Guzmán Jiménez Supervisor: Dr. Mario Javier Durán Martínez Dr. Federico José Barrero García Doctoral Program: Mechatronic Engineering Electrical Engineering Department, University of Málaga Málaga, 2015 2015 Hugo M. Guzmán Jiménez
Doctoral Thesis “EXTENSION OF FINITE-CONTROL SET MODEL-BASED PREDICTIVE CONTROL TECHNIQUES TO FAULT-TOLERANT MULTIPHASE DRIVES: ANALYSIS AND CONTRIBUTIONS” PhD Candidate: Hugo M. Guzmán Jiménez Supervisor: Dr. Mario Javier Durán Martínez Dr. Federico José Barrero García Doctoral Program: Mechatronic Engineering A Dissertation Submitted to the Faculty of Electrical Engineering of the University of Málaga in Partial Fulfillment of the Requirements for the Degree of DOCTOR OF PHILOSOPHY Electrical Engineering Department, University of Málaga C/ Doctor Ortiz Ramos s/n. Málaga 29071. Spain. Málaga, 2015
AUTOR: Hugo Mauricio Guzmán Jiménez http://orcid.org/0000-0001-8564-2421 EDITA: Publicaciones y Divulgación Científica. Universidad de Málaga Esta obra está sujeta a una licencia Creative Commons: Reconocimiento - No comercial - SinObraDerivada (cc-by-nc-nd): Http://creativecommons.org/licences/by-nc-nd/3.0/es Cualquier parte de esta obra se puede reproducir sin autorización pero con el reconocimiento y atribución de los autores. No se puede hacer uso comercial de la obra y no se puede alterar, transformar o hacer obras derivadas. Esta Tesis Doctoral está depositada en el Repositorio Institucional de la Universidad de Málaga (RIUMA): riuma.uma.es
I ABSTRACT Nowadays the world is in the constant need to develop new technologies that are capable of changing from the traditional oil-based energy scheme to a more environmentally friendly energy economy. Research and development projects throughout the world aim to generate new and more efficient systems, capable of either generating energy by renewable energies or to electrify different transportation systems. Three-phase electrical drives have been traditionally used in energy generation systems and are considered a mature technology. Nonetheless, the inclusion of new energy generation systems and its more recent implementation for transportation means, have posed new challenges regarding the amount of energy they can manage, their efficiency and their reliability. Among the technologies proposed to cope with these challenges, multiphase machines have been recognized in the last few years as a viable solution for applications where the reduction in the total power per phase, the higher overall system reliability and the ability to continue operation under faulty conditions are required. Electric vehicles and railway traction, all-electric ships, more-electric aircraft or wind power generation systems are examples of up-to-date real applications using multiphase machines, most of them taking advantage of the ability to maintain post-fault operation. Among the available multiphase machines topologies, asymmetrical six phase machines and five-phase induction machines with sinusoidally distributed stator windings are the most frequently considered, and a significant amount of research work has been done in the last few years aiming to exploit their advantages and make them an interesting option for industrial applications. Moreover, the development of more powerful digital signal processors has made possible the adoption of more complex control techniques capable of considering different constraints, working conditions and larger systems. This is the case of predictive controllers, which have been recently proposed for multiphase drive control, considering systems with different number of phases and topologies, for drive operation under torque, speed or current control, common-mode voltage reduction and sensorless operation, among many others.
Abstract II The purpose of this Doctoral Thesis work is to extend predictive control schemes for multiphase drives, more specifically finite-control set model-based predictive control, to the faulttolerant operation, exploiting the fault tolerance that multiphase drives possess and ensure efficient and controlled post-fault operation. Although the research of this Thesis is suitable for any type of multiphase drive, the study has been particularized for a five-phase induction motor with sinusoidally distributed windings and fed by a two-level inverter. Two main types of faults are studied, namely, the open-phase fault and the IGBT-gating failure. Due to the nature of predictive controllers, an accurate system model under the different working conditions is necessary in order to properly select the best control action (voltage vector) to be applied to the power converter. Consequently, the electrical drive modeling equations have been studied and the effect of the different types of faults on the electrical machine and the power converter are considered. This Doctoral Thesis contribution is divided in three journal papers published in the IEEE Transactions on Industrial Electronics. The first journal paper discusses the proposed open-phase fault-tolerant scheme based on finite-control set model based predictive control and the electrical drive modeling under an open-phase fault. The controllers’ performance is verified through a set of experimental tests, subjecting the electrical drive to different working conditions, considering prefault operation, the transition between normal and post-fault operation and finally, post-fault operation considering different criteria such as reducing copper losses or ensuring minimum drive derating. The second journal paper considers an IGBT-gating fault in both semiconductors of the same phase, leading to a non-controlled current in the five-phase drive. The effect that such type of fault has on the electrical drive and on the proposed open-phase predictive controller is assessed, demonstrating that the proposed fault-tolerant scheme is capable of managing this type of fault at the expense of a negligible extra torque derating. Finally, an experimental comparison between a fault-tolerant linear control scheme based on proportional-resonant regulators and the proposed predictive fault-tolerant scheme is presented in the third journal paper. As in previous papers, the controller’s performance is evaluated and compared under different working conditions and criteria, providing further insight on the specific benefits of each control scheme. The journal papers discussed in this Doctoral Thesis are: 1. H. Guzman, M.J. Duran, F. Barrero, B. Bogado, S. Toral, “Speed Control of Five- Phase Induction Motors With Integrated Open-Phase Fault Operation Using Model-
Abstract III Based Predictive Current Control Techniques,” IEEE Transactions on Industrial Electronics, vol. 61, no. 9, pp. 4474-4484, Sept. 2014. 2. H. Guzman, F. Barrero, M. Duran, “IGBT-Gating Failure Effect on a Fault-Tolerant Predictive Current Controlled 5-Phase Induction Motor Drive,” IEEE Transactions on Industrial Electronics, vol. 62, no. 1, pp. 15-20, Jan. 2015. 3. H. Guzman, M. J. Duran, F. Barrero, L. Zarri, B. Bogado, I. Gonzalez Prieto, M. R. Arahal. “Comparative Study of Predictive and Resonant Controllers in Fault-Tolerant Five- Phase Induction Motor Drives”, IEEE Transactions on Industrial Electronics, DOI: 10.1109/TIE.2015.2418732.
IV ACKNOWLEDGMENTS I would like to specially thank my parents, sister and grandparents whose support has been unconditional, their kind words when needed and their love, made possible the culmination of this work. To Tatiana for accompanying me in this journey and helping me to discern between what’s important and what’s not. To Vite and Joel. I’ll always look forward to see you. Thank you for your friendship, your support and all the moments we enjoyed. To my friends in this second home, Spain. All of you that have accompanied us since the beginning up until the end. You that made us feel welcome in Seville and in Málaga. Who shared your life with us and tried to make us feel at home. To my friends in Colombia, who always stood by my side and received me with a big smile. To Federico and Mario, who guided me through this work. You where my advisors when needed, and always my friends. You pushed me continuously to do better and together we succeeded. Thank you for welcoming us into your families and sharing with us your life.
List of Figures X 3.1 Pre- and postfault drive topology and proposed control scheme based on an outer speed and flux loop and an inner open-phase fault-tolerant FCS-MPC current control ....................................................... 74 3.2 Mapping of the α–β components for the five-phase system under normal (a) and open-phase fault operation implementing the traditional Clarke transformation (b) and the modified Clarke transformation (c) ....................................................................................................................................... 75 3.3 Electrical drive topology reconfiguration under IGBT-Gating failure and control scheme based on an outer speed and flux loop and an inner fault-tolerant FCS-MPC current control ................................ 78 3.4 Pre- and postfault drive topology and implemented control scheme based on an outer speed and flux loop and an inner open-phase fault-tolerant PR controller ............................................................................. 81
1 CHAPTER: 1 MOTIVATION, OBJECTIVES AND DOCUMENT ORGANIZATION 1.1 MOTIVATION BEHIND THIS WORK Electrical machines constitute one of the cornerstones of renewable energies and electric vehicle propulsion. The constant necessity for higher power ratings in order to either generate more energy or to provide electromechanical force for larger vehicles, has motivated research and development activities in multiphase drives. The ability to manage more power with lower torque pulsation and lower current harmonic content and achieve higher fault-tolerance capability, than conventional three-phase drives [1], makes them an ideal candidate for applications where reliability is of special interest for economical and/or safety reasons. Although up until now multiphase drives implementation in industry applications is not widely spread, it is foreseeable that with the development of larger wind energy turbines and the advances on more electric aircrafts, ships and vehicles, with higher fault-tolerance standards and requirements, multiphase machines will gain significant interest. Recent research work on multiphase drives aims to exploit multiphase machines special characteristics and present them to the industry as a viable solution for different applications, regarding its higher number of phases not as an increase on its implementation complexity, but as a higher control and design degrees of freedom, that can improve overall reliability and performance. Consequently, different control techniques aiming for high speed or high torque operation, fault resiliency under different types of faults, types of winding and multidrive and multi-motor connections, have been proposed. The following Doctoral thesis work is focused on the study of multiphase machines under different fault conditions and the development/comparison of control strategies that are capable of ensuring post-fault operation.
Chapter 1 2 1.2 OBJECTIVES The general and specific objectives of this Doctoral Thesis work are: 1.2.1 GENERAL OBJECTIVE The extension of predictive control schemes for multiphase drives, more specifically finitecontrol set model-based predictive control, to the fault-tolerant operation, exploiting the faulttolerance capability that multiphase drives possess and ensure efficient and controlled post-fault operation. 1.2.2 SPECIFIC OBJECTIVES Research on multiphase motors, their advantages, disadvantages and their industrial application in electric vehicle propulsion and wind energy generation systems. Analyze the effect of different types of faults on the electrical drive and develop new and interesting mathematical models for multiphase drives under different fault conditions. Study of multiphase drives control techniques under pre- and post-fault working conditions. Identify the post-fault system limitations and constraints, considering a five-phase induction drive with two level voltage source inverters, and propose different faulttolerant management techniques in order to ensure the maximum energy optimization. Study and analyze conventional three-phase predictive control strategies and extend them to multiphase drives and fault-tolerance. Implement, compare and assess the performance of fault-tolerant linear and predictive control techniques under different working conditions operation. 1.3 DOCUMENT ORGANIZATION This Doctoral thesis is organized following the directives given by the University of Málaga for an article compendium thesis. The document is divided in three main parts. In the first part, the motivation and objectives of this doctoral research work are presented (Chapter 1), along with the generalities and the state of the art of multiphase drives (Chapter 2), where a thorough study of the available scientific publications on multiphase drives modelling and control techniques under pre-
Introduction 3 and post-fault operation are presented. Subsequently, the thesis contributions and its analysis is then presented in the second part (Chapter 3). The first two contributions are based on the proposal (Journal paper 1) of a fault-tolerant model-based predictive controller for five-phase induction machines under open-phase faults and the subsequent study (Journal paper 2) of such controller under an IGBT-gating failure. The third contribution is based on a comparative analysis of the proposed fault-tolerant predictive controller with a fault-tolerant proportional resonant controller, further clarifying the main advantages and disadvantages of each controller under an open-phase fault situation (Journal paper 3). Finally, a summary of the journal papers, conference works, patents and research projects behind this doctoral thesis (which were not included as the main contributions), along with conclusions and future work, are presented in the third part of the document (Chapter 4).
4 CHAPTER: 2 MULTIPHASE DRIVES: GENERALITIES, MODELING AND CONTROL 2.1 INTRODUCTION In this chapter a thorough literature review on five-phase induction machines and power converters modeling equations is presented. Correspondingly some of the standard linear, nonlinear and predictive control techniques, available in the literature for multiphase drives operation are discussed. Multiphase motor drives, based on electrical machines with more than three phases, were proposed nearly 50 years ago. However, they have only gained special attention of the research community during the past few years after the development of high power and high switching frequency semiconductor devices, like IGBT’s, and powerful microelectronic control units, like DSP’s and FPGA’s [1], enabling efficient and proper control of multiphase machines. This has led researchers to propose multiphase drives technology for high performance, high power and faulttolerant applications such as wind energy generation [2], aerospace [3] and vehicle propulsion [4, 5]. Regarding industrial implementations, multiphase drives can be found in i) ultra-high speed elevators [6], using a nine-phase permanent-magnet machine controlled by three three-phase power converters, ii) ship propulsion [7, 8], where an Alstom “Advanced Induction Motor” of 20 MW, fifteen-phase with three independent neutral points and controlled by three five-phase power converters, was implemented in a US Navy electric ship prototype and iii) the refrigeration string of a Liquefied Natural Gas (LNG) installation as reported in [8], where a 45 MW, 7200 volts, twelve-phase motor, with four independent neutral points, controlled by four IGBT based, three-phase cascaded multilevel converters was designed and constructed. Previous uses prove that multiphase drives are a viable solution for high power, safety critical applications and capable of meeting industry standards. Some of the advantages of multiphase drives when compared with standard three-phase motor
Chapter 2 5 drives [1, 9, 10, 11] are: 1. Improved spatial distribution of the Magneto Motive Force (MMF) in the machine air gap [9], reducing rotor copper losses. 2. Lower harmonic content in the stator excitation currents. 3. Lower torque pulsations. Multiphase machines are less susceptible to torque pulsations at low frequencies, the lowest torque pulsation frequency in an 𝑛-phase machine is caused by harmonics of the order (2𝑛±1). 4. Less harmonic content in the DC-Link currents. 5. Improved power distribution. For a given nominal power, the current rating through each phase decreases as the number of phases increases. 6. Higher number of control degrees of freedom, allowing: a. High torque density drives: In multiphase machines with concentrated windings, it is possible to use the lower current harmonic components (third harmonic in a five-phase machine, third and fifth harmonics in a seven-phase machine, and so on) to increase torque production capability [12, 13]. b. Multimotor drives. By connecting in series the stator windings of a set of distributed windings multiphase machines, different number of machines can be independently controlled with only one power converter [14, 15]. c. Fault-Tolerant Drives: More reliable than their three-phase counterparts. In a three phase machine in case of an open-phase fault, the machine can still work as a one-phase machine but it would need external equipment in order to start up the machine and control torque oscillations. On the other hand, an 𝑛-phase machine with one or more of its phases in fault condition (depending on its total number of phases (𝑛) and its constructive characteristics), could continue developing a rotating field as long as the number of open-circuited phases is no more than (𝑛− 3), at the expense of lower torque and current ratings, without requiring external equipment. Multiphase machines are traditionally classified depending on the winding distribution as concentrated or distributed windings’ machines and on the winding arrangement like symmetrical or asymmetrical machines. Concentrated windings’ multiphase machines generate a high harmonic field flux content when a sinusoidal stator voltage is applied, which can be used to enhance the electrical
Multiphase Drives: Generalities, Modeling and Control 6 torque production. However, this flux harmonic content only generates electromagnetic losses in the machine if the distributed winding topology is used. On the other hand, symmetrical machines are formed by consecutive phase windings equally displaced 2𝜋/𝑛, while asymmetrical machines are formed by independent set of windings displaced 𝜋/𝑛. Moreover, multiphase machines can be further classified by the number of odd or even phases they possess [17, 18, 19] and if the number of phases is multiple of three [20, 21, 22]. Among machines with an even number of phases, six-phase machines are the most common ones in scientific literature. These type of machines can be found with asymmetrical (30°) or symmetrical (60°) winding distribution and single or dual neutral points. However, the most commonly used structure is based on two three-phase asymmetric windings and two independent neutral points, also called dual three-phase machines. A considerable body of knowledge has been developed regarding the modeling of these machines [22], and their control techniques (based on field oriented [23, 24, 25, 26], direct torque [27, 28], or predictive control [29, 30]) or modulation strategies [31, 32, 33]. On the other hand, machines with an odd number of phases are sometimes preferred for their inherent symmetric structure. These types of machines are constructed in star-winding connection, with a single neutral and can be found either with concentrated or distributed windings. This is the case of five-phase machines, where several modulation and control techniques have been proposed in the literature, based on carrier-based pulse width modulation and space vector modulation [34, 35, 36], field oriented control [13, 37, 38], direct-torque control [39, 40] and predictive control [41, 42], aimed to exploit the advantages multiphase machines possess, maintaining sinusoidal or non-sinusoidal stator voltages, depending on the winding distribution. Furthermore, depending on whether the number of phases it possesses is a prime number or not, different winding dispositions can be obtained, resulting in machines with single neutral, multiple neutral points or with polygon configuration. The effect of the winding configuration during different working states has been analyzed in [43, 44, 45], where it has been shown that properly changing the stator winding configuration can benefit torque/speed operation. An 𝑛-phase machine stator windings can be connected in ((𝑛+1)2 ⁄), different configurations. For instance a five-phase drive can be connected in star, pentagon or pentacle configuration, where for the same DC-Link voltage and drive power rating, the voltage across the winding is higher in the pentacle configuration, followed by the pentagon and star connection and conversely phase currents are higher in star connection followed by pentagon and pentacle configurations. As a result, star winding configuration will provide higher
Chapter 2 7 torque with lower speed operation, while pentagon winding connection will provide less torque but slightly more speed and finally pentacle connection will provide high speed operation at lower torque. As was demonstrated in [46, 47], it is possible to control multiple series connected multiphase machines from a single power converter by connecting each of the machines stator windings in series with a particular phase transposition in order to decouple the effect of the currents producing torque and flux of one machine in the other set of machines. Multimotor drive configuration has been studied implementing five- and six-phase machines [48, 49, 50], as well as topologies consisting of machines with different number of phases or different types of machines [51, 52]. By implementing multiple Field Oriented Control (FOC) loops, one for each pair of currents in the Vector Space Decomposition (VSD) frame, it is possible to properly exploit the additional degrees of freedom that multiphase drives possess and control for example in a five-phase drive, two machines independently. Phase winding transposition is made in order to ensure that one machines 𝑑-𝑞 currents represent the 𝑥-𝑦 currents of the remaining machine, and therefore do not influence the torque production. Consequently, the 𝑑-𝑞 current components are used to control torque and flux production of the first machine and the 𝑥-𝑦 current components are used to control, in a similar way, torque and flux components of the second machine. Nonetheless, multimotor drive topology results in an increase of copper losses and does not provide fault-tolerant operation capability, due to the fact that the additional degrees of control freedom exploited, in multiphase drives, for fault-tolerance are used in order to independently control each machine. Furthermore, multimotor drive configuration is not feasible with concentrated winding machines due to the fact that 𝑥-𝑦 current components influence torque production and consequently independent control of each multiphase machine is not possible. As can be seen, multiphase drives are an interesting technology, formed by a considerable number of machines and power converter topologies. Their special benefits and capabilities have made them attractive within research community and some industrial applications, stating their future importance as transportation and energy generation increase their power ratings. Thus the need for continuous research on the subject is justified in order to meet industry and safety standards while exploiting multiphase machines benefits at reasonable costs.
Multiphase Drives: Generalities, Modeling and Control 8 2.2 MODELING The general scheme of the multiphase drive used in this doctoral thesis is presented in Fig. 2.1. The system consists of a two-level IGBT based power converter and a five-phase induction machine. In first place, the modeling equations for the distributed winding five-phase induction machine will be described and the physical model of the machine in phase variables will be studied. Then, in order to reduce the model complexity and the number of state variables necessary to control the machine, the model is analyzed in the stationary (𝛼,𝛽,𝑥,𝑦) reference frame using the Clarke transformation. Next, for control purposes, the machine model will be analyzed in the rotating (𝑑-𝑞) reference frame, by means of the Park transformation. Finally, the power converter modeling will be addressed. The phase and line voltages dependent on the inverter switching state will be studied, the available voltage space vectors in the (𝛼,𝛽,𝑥,𝑦) planes and drive load configuration will be depicted and the effect of voltage vectors in the common-mode voltage will be presented. Vdc/2 Vdc/2 ias ibs ids ics ies + - vbs vas + - + vcs -ves - + - vds + Sb Sb Sc Sc Sd Sd Se Se P N O Sa Sa w m Te n ABCDE vae vCM Fig. 2.1.: Five-phase two-level induction motor drive scheme. The induction machine under study is based on a 30-slots, three-phase induction machine with 2-pairs of poles (𝑃) whose stator has been rewound to obtain a five-phase (𝑛=5) induction machine with 3 pairs of poles. The stator is formed by five windings evenly distributed around the stator circumference with an electrical displacement of =2𝜋/5=72° and the rotor has a squirrel cage single-neutral topology, equivalent to five windings evenly distributed with an electrical displacement of 72°, as shown in Fig. 2.2.
Chapter 2 15 [𝑣𝑠𝛼 𝑣𝑠𝛽 00]= [ 𝑅𝑠+𝑑 𝑑𝑡𝐿𝑠0𝑑 𝑑𝑡𝐿𝑚0 0 𝑅𝑠+𝑑 𝑑𝑡𝐿𝑠0𝑑 𝑑𝑡𝐿𝑚 𝑑 𝑑𝑡𝐿𝑚𝐿𝑚𝜔𝑟𝑅𝑟+𝑑 𝑑𝑡𝐿𝑟𝐿𝑟𝜔𝑟 −𝐿𝑚𝜔𝑟𝑑 𝑑𝑡𝐿𝑚−𝐿𝑟𝜔𝑟𝑅𝑟+𝑑 𝑑𝑡𝐿𝑟 ] ∗ [ 𝑖𝑠𝛼 𝑖𝑠𝛽 𝑖𝑟𝛼 𝑖𝑟𝛽 ] (46) And their equivalents in complex vector are: 𝑣𝑠𝛼𝛽 =𝑅𝑠𝑖𝑠𝛼𝛽 +𝑑 𝑑𝑡𝜆𝑠𝛼𝛽 (47) 0=𝑅𝑟𝑖𝑟𝛼𝛽 +𝑑 𝑑𝑡𝜆𝑟𝛼𝛽 −𝑗𝜔𝑟𝜆𝑟𝛼𝛽 (48) 𝜆𝑠𝛼𝛽 =𝐿𝑠𝑖𝑠𝛼𝛽 +𝐿𝑚𝑖𝑟𝛼𝛽 (49) 𝜆𝑟𝛼𝛽 =𝐿𝑚𝑖𝑠𝛼𝛽 +𝐿𝑟𝑖𝑟𝛼𝛽 (50) where the complex electrical vectors are defined as: 𝑣𝑠𝛼𝛽 =𝑣𝑠𝛼+𝑗𝑣𝑠𝛽 (51) 𝑣𝑟𝛼𝛽 =𝑣𝑟𝛼+𝑗𝑣𝑟𝛽 (52) 𝑖𝑠𝛼𝛽 =𝑖𝑠𝛼+𝑗𝑖𝑠𝛽 (53) 𝑖𝑟𝛼𝛽 =𝑖𝑟𝛼+𝑗𝑖𝑟𝛽 (54) 𝜆𝑠𝛼𝛽 =𝜆𝑠𝛼+𝑗𝜆𝑠𝛽 (55) 𝜆𝑟𝛼𝛽 =𝜆𝑟𝛼+𝑗𝜆𝑟𝛽 (56) In a similar way, the (𝑥,𝑦) subspace voltage and flux rotor components are obtained through (27)-(28) and represented in matrix and complex vector form, as shown in (57)-(62). [𝑣𝑠𝑥 𝑣𝑠𝑦]=[𝑅𝑠+𝑑 𝑑𝑡𝐿𝑙𝑠 0 0 𝑅𝑠+𝑑 𝑑𝑡𝐿𝑙𝑠][𝑖𝑠𝑥 𝑖𝑠𝑦] (57) [00]=[𝑅𝑟+𝑑 𝑑𝑡𝐿𝑙𝑟 0 0 𝑅𝑟+𝑑 𝑑𝑡𝐿𝑙𝑟][𝑖𝑟𝑥 𝑖𝑟𝑦] (58) 𝑣𝑠𝑥𝑦 =𝑅𝑠𝑖𝑠𝑥𝑦 +𝑑 𝑑𝑡𝜆𝑠𝑥𝑦 (59) 0=𝑅𝑟𝑖𝑟𝑥𝑦 +𝑑 𝑑𝑡𝜆𝑟𝑥𝑦 (60) 𝜆𝑠𝑥𝑦 =𝐿𝑙𝑠𝑖𝑠𝑥𝑦 (61) 𝜆𝑟𝑥𝑦 =𝐿𝑙𝑟𝑖𝑟𝑥𝑦 (62)
Multiphase Drives: Generalities, Modeling and Control 16 where the complex electrical vectors are defined as: 𝑣𝑠𝑥𝑦 =𝑣𝑠𝑥+𝑗𝑣𝑠𝑦 (63) 𝑣𝑟𝑥𝑦 =𝑣𝑟𝑥+𝑗𝑣𝑟𝑦 (64) 𝑖𝑠𝑥𝑦 =𝑖𝑠𝑥+𝑗𝑖𝑠𝑦 (65) 𝑖𝑟𝑥𝑦 =𝑖𝑟𝑥+𝑗𝑖𝑟𝑦 (66) 𝜆𝑠𝑥𝑦 =𝜆𝑠𝑥+𝑗𝜆𝑠𝑦 (67) 𝜆𝑟𝑥𝑦 =𝜆𝑟𝑥+𝑗𝜆𝑟𝑦 (68) Finally, the (𝑧), subspace obtained through (27)-(28) is: 𝑣𝑠𝑧=(𝑅𝑠+𝑑 𝑑𝑡𝐿𝑙𝑠)𝑖𝑠𝑧 (69) 𝑣𝑟𝑧=(𝑅𝑟+𝑑 𝑑𝑡𝐿𝑙𝑟)𝑖𝑟𝑧 (70) Notice that as a result of the VSD applied to the voltage equations, the machine can be electrically modeled by three sets of independent circuits for (𝛼,𝛽), (𝑥,𝑦) and (𝑧) planes, Fig. 2.3. d/dt Lls d/dt Llr d/dt Lm Rsj w r l r ab vs ab Rr +- is ab ir ab d/dt Lls Rs vsxy isxy d/dt Lls Rs vsz isz Fig. 2.3.: Five-phase induction machine equivalent circuit in the (𝜶,𝜷,𝒙,𝒚) planes. The electromagnetic torque can be calculated [54] by equation (23), mapped in the (𝛼,𝛽,𝑥,𝑦) reference frame as follows: 𝑇𝑒=𝑃([𝐼𝑠]𝛼𝛽𝑥𝑦𝑧 𝑇[𝑇𝑐]𝑑 𝑑𝜃𝐿𝑠𝑟(𝜃)[𝑇𝑐]−1[𝑇𝑟(−𝜃)][𝐼𝑟]𝛼𝛽𝑥𝑦𝑧) (71) Notice that: [𝑇𝑐]𝑑 𝑑𝜃[𝐿𝑠𝑟(𝜃)][𝑇𝑐]−1=𝑑 𝑑𝜃([𝑇𝑐]∗[𝐿𝑠𝑟(𝜃)]∗[𝑇𝑐]−1)=𝐿𝑚𝑑 𝑑𝜃 [ cos(𝜃)−sin(θ)0 0 0 sin(θ)cos(𝜃)0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ] (72)
Chapter 2 17 𝑑 𝑑𝜃([𝑇𝑐][𝐿𝑠𝑟(𝜃)][𝑇𝑐]−1)=𝐿𝑚 [ −sin(θ)−cos(𝜃)0 0 0 cos(𝜃)−sin(θ)0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ] (73) As it was expected the (𝑥,𝑦), (𝑧), subspace electric variables are zero; this demonstrates that the electromechanical energy conversion takes place only in the (𝛼,𝛽) subspace components. Taking this into account, the electromagnetic torque can be calculated by: 𝑇𝑒=𝑃𝐿𝑚[𝑖𝑠𝛼 𝑖𝑠𝛽][−𝑠𝑖𝑛(𝜃)−𝑐𝑜𝑠(𝜃) 𝑐𝑜𝑠(𝜃)−𝑠𝑖𝑛(𝜃)][𝑐𝑜𝑠(𝜃)𝑠𝑖𝑛(𝜃) −𝑠𝑖𝑛(𝜃)𝑐𝑜𝑠(𝜃)][𝑖𝑟𝛼 𝑖𝑟𝛽]= 𝑃𝐿𝑚[𝑖𝑠𝛼 𝑖𝑠𝛽][0 −1 1 0][𝑖𝑟𝛼 𝑖𝑟𝛽] (74) 𝑇𝑒= 𝑃𝐿𝑚(𝑖𝑟𝛼𝑖𝑠𝛽−𝑖𝑟𝛽𝑖𝑠𝛼) (75) Notice that the electromagnetic torque in the stationary reference frame, can be also expressed in complex vector form in terms of the rotor and stator currents (76), stator flux and current (77), rotor flux and current (78) and rotor flux and stator current (79). This is of special importance for control purposes where different schemes are implemented depending on the selected torque expression. 𝑇𝑒= 𝑃𝐿𝑚(𝑖𝑟𝛼𝛽 ×𝑖𝑠𝛼𝛽 ) (76) 𝑇𝑒= 𝑃(𝜆𝑠𝛼𝛽 ×𝑖𝑠𝛼𝛽 ) (77) 𝑇𝑒= 𝑃(𝜆𝑟𝛼𝛽 ×𝑖𝑟𝛼𝛽 ) (78) 𝑇𝑒= 𝑃𝐿𝑚 𝐿𝑟(𝜆𝑟𝛼𝛽 ×𝑖𝑠𝛼𝛽 ) (79) 2.2.1.3 ROTATING REFERENCE FRAME The VSD theory applied to the voltage, current and flux equations in the stationary stator reference frame allows a significant simplification of the dynamic modeling equations. Moreover, it is observed that only (𝛼,𝛽) components are involved in torque production and consequently are a priority for control purposes. Under transient conditions these components possess an oscillating nature that must be avoided in order to ensure proper control. To achieve this, voltage, current and flux vectors are mapped in a rotating reference frame (𝑑-𝑞) at a constant speed (𝜔𝑎). Consequently, the 𝑑- and 𝑞components of each vector in the common reference frame, are non-oscillating, constant in steady state and varying in transient state [55]. The vector rotation into the (𝑑-𝑞) reference frame is achieved by means of the Park transformation (80) for stator components (𝑇𝑠𝑝) and (81) for rotor components (𝑇𝑟𝑝), as shown graphically in Fig. 2.4.
Multiphase Drives: Generalities, Modeling and Control 18 -vbr var - +vcr - ver - - vdr n w m a -axis b -axis a r-axis Rr Llsr q + + + + b r-axis d-axis q-axis d q a w r w a Fig. 2.4.: Park rotating reference frame. The rotating 𝑑- and 𝛼𝑟axes instantaneous position with respect to the stationary stator 𝛼-axis reference frame is denoted by (𝜃𝑎) and (𝜃), respectively. Consequently the rotating 𝛼𝑟-axis position with respect to the 𝑑reference frame (𝛿), is given by (82). Notice that the (𝛼𝑟,𝛽𝑟) vectors are rotating at a speed denoted by (𝜔𝑟), related to the mechanical speed by (83) and to their instantaneous position by (84). On the other hand, the (𝑑-𝑞) plane is rotating at a speed (𝜔𝑎) and is related to its instantaneous position by (85). [𝑇𝑠𝑝]=[cos (𝜃𝑎) −sin (𝜃𝑎) sin (𝜃𝑎)cos (𝜃𝑎)] (80) [𝑇𝑟𝑝]=[cos (𝛿) −sin (𝛿) sin (𝛿) cos (𝛿)] (81) 𝛿=𝜃𝑎−𝜃 (82) 𝜔𝑟=𝑃𝜔𝑚 (83) 𝛿=∫(𝜔𝑎−𝜔𝑟)𝑑𝑡 𝑡 0=∫𝜔𝑠𝑙𝑑𝑡 𝑡 0 (84) 𝜃𝑎=∫𝜔𝑎𝑑𝑡 𝑡 0 (85) As a result, applying (80) and (81) to the (𝛼,𝛽) stator/rotor voltage components, the voltage matrix defined in (46) and the electromagnetic torque (𝛼,𝛽), can be expressed in the rotating reference frame by (86) and (87), respectively. Moreover, the machines equivalent electrical model in the 𝑑-𝑞 reference frame will be as shown in Fig. 2.5. Observe that the equivalent circuit in the 𝑥-𝑦 components remain the same as in the stationary reference frame due to the fact that vector rotation is only applied to the (𝛼,𝛽) components.
Chapter 2 19 [𝑣𝑠𝑑 𝑣𝑠𝑞 00]= [ 𝑅𝑠+𝑑 𝑑𝑡𝐿𝑠−𝐿𝑠𝜔𝑎𝑑 𝑑𝑡𝐿𝑚−𝐿𝑚𝜔𝑎 𝐿𝑠𝜔𝑎𝑅𝑠+𝑑 𝑑𝑡𝐿𝑠𝐿𝑚𝜔𝑎𝑑 𝑑𝑡𝐿𝑚 𝑑 𝑑𝑡𝐿𝑚−𝐿𝑚𝜔𝑠𝑙 𝑅𝑟+𝑑 𝑑𝑡𝐿𝑟−𝐿𝑟𝜔𝑠𝑙 𝐿𝑚𝜔𝑠𝑙 𝑑 𝑑𝑡𝐿𝑚𝐿𝑟𝜔𝑠𝑙 𝑅𝑟+𝑑 𝑑𝑡𝐿𝑟 ] ∗[𝑖𝑠𝑑 𝑖𝑠𝑞 𝑖𝑟𝑑 𝑖𝑟𝑞] (86) 𝑇𝑒= 𝑃𝐿𝑚(𝑖𝑟𝑑𝑖𝑠𝑞−𝑖𝑟𝑞𝑖𝑠𝑑) (87) d/dt Lls d/dt Llr d/dt Lm Rsj( w aw r) l rdq vsdq Rr isdq irdq d/dt Lls Rs vsxy isxy d/dt Lls Rs vsz isz +- j w a l sdq +- Fig. 2.5.: Five-phase induction machine equivalent circuit in the (𝒅,𝒒,𝒙,𝒚) planes. Notice that the electromagnetic torque equation can be written in terms of the stator or rotor flux as in (88) and (89), respectively. This is of special importance for control purposes where different schemes can be implemented by setting the 𝑑-axis fixed to either the air-gap, stator or rotor flux component, as will be studied further on. 𝑇𝑒= 𝑃(𝜆𝑠𝑑𝑖𝑠𝑞−𝜆𝑠𝑞𝑖𝑠𝑑) (88) 𝑇𝑒= 𝑃𝐿𝑚 𝐿𝑟(𝜆𝑟𝑑𝑖𝑠𝑞−𝜆𝑟𝑞𝑖𝑠𝑑) (89) 2.2.2 MULTIPHASE POWER CONVERTER MODELING Power converters are in charge of converting energy from AC to DC or vice versa, controlling its voltage, current and frequency characteristics. Depending on its nature or application requirements, different topologies can be found in the literature, distinguished by the number of phases they possess (single phase, three-phase or multiphase) and the number of voltage levels they use to synthetize the modulated current/voltage (two-level, multilevel). Depending on the electrical ratings of the final application, the power converter can be constructed implementing different semiconductor technologies. For instance, power converters where high switching frequency (1 MHz), low voltage
Multiphase Drives: Generalities, Modeling and Control 20 (up to 1 kV) and low current (around 100 A) is required are commonly based on Metal Oxide Semiconductor Field Effect (MOSFET), however if the voltage and current ratings increase (in the order of kV and kA) Insulated Gate Bipolar Transistor (IGBT), are used at the expense of lower switching frequencies. The general scheme of the five-phase two-level induction motor drive is depicted in Fig. 2.1. The power converter consists of a voltage source inverter (VSI), based on ten IGBT semiconductors and its corresponding anti-parallel free-wheeling diode, two for each phase, whose electrical ratings are able to withstand the entire DC-Link voltage and the maximum rated current of the induction machine. The DC-Link voltage is provided by an external low-impedance DC source. Each phase IGBT’s switching state is denoted by (𝑆𝑖). Where 𝑆𝑖=0 if the lower switch is ON and the upper switch is OFF, connecting the machine winding to the negative rail of the converter (𝑁) and 𝑆𝑖=1 if the opposite occurs, connecting the phase winding to the positive rail (𝑃). Consequently only two voltage levels are applied namely, 0−𝑉𝑑𝑐, when referred to the negative rail of the VSI or ±𝑉𝑑𝑐 2 ⁄, if referred to the DC-Link mid-point. Accordingly, the leg voltage, referred to the negative rail of the VSI, is given in terms of the semiconductor switching state (𝑆𝑖) and the DC-Link voltage (90). 𝑣𝑖𝑁=𝑆𝑖𝑉𝑑𝑐 (90) During normal operation the sum of the machines phase voltages is zero (91), where each phase voltage (𝑣𝑖𝑠), can be written in terms of the voltage between phase (𝑖) and the negative rail of the converter (𝑁) and the voltage between the machines neutral point (𝑛) and the inverters negative rail (92). ∑[𝑣𝑖𝑠]=𝑣𝑎𝑠+𝑣𝑏𝑠+𝑣𝑐𝑠+𝑣𝑑𝑠+𝑣𝑒𝑠=0 (91) 𝑣𝑖𝑠=𝑣𝑖𝑁−𝑣𝑛𝑁 (92) Consequently further developing (91), considering the phase voltage in (92). 𝑣𝑎𝑁+𝑣𝑏𝑁+𝑣𝑐𝑁+𝑣𝑑𝑁+𝑣𝑒𝑁−5𝑣𝑛𝑁=0→𝑣𝑛𝑁=15(𝑣𝑎𝑁+𝑣𝑏𝑁+𝑣𝑐𝑁+𝑣𝑑𝑁+𝑣𝑒𝑁) (93) On the other hand, the machines phase and line voltage matrix can be written as: [ 𝑣𝑎𝑁 𝑣𝑏𝑁 𝑣𝑐𝑁 𝑣𝑑𝑁 𝑣𝑒𝑁 0 ] = [ 1 0 0 0 0 1 0 1 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 0 0 1 1 −1 −1 −1 −1 −1 0 ] [ 𝑣𝑎𝑠 𝑣𝑏𝑠 𝑣𝑐𝑠 𝑣𝑑𝑠 𝑣𝑒𝑠 𝑣𝑛𝑁 ] (94)
Chapter 2 21 Applying the inverse transformation to (94), the phase voltages can be calculated in terms of the leg voltages by: [ 𝑣𝑎𝑠 𝑣𝑏𝑠 𝑣𝑐𝑠 𝑣𝑑𝑠 𝑣𝑒𝑠 ] =15 [ 4 −1 −1 −1 −1 −1 4 −1 −1 −1 −1 −1 4 −1 −1 −1 −1 −1 4 −1 −1 −1 −1 −1 4 ] [ 𝑣𝑎𝑁 𝑣𝑏𝑁 𝑣𝑐𝑁 𝑣𝑑𝑁 𝑣𝑒𝑁 ] (95) Considering that the leg voltage is given in terms of the switching state (𝑆𝑖) and the DC-Link voltage (90), the stator phase voltage matrix (95), from now on (𝑉𝑝𝑟𝑒), can be written as: [ 𝑣𝑎𝑠 𝑣𝑏𝑠 𝑣𝑐𝑠 𝑣𝑑𝑠 𝑣𝑒𝑠 ] =𝑉𝑑𝑐 5 [ 4 −1 −1 −1 −1 −1 4 −1 −1 −1 −1 −1 4 −1 −1 −1 −1 −1 4 −1 −1 −1 −1 −1 4 ] [ 𝑆𝑎 𝑆𝑏 𝑆𝑐 𝑆𝑑 𝑆𝑒 ] =𝑉𝑝𝑟𝑒 (96) From (96) it is possible to see that different load configurations are obtained depending on the five-phase drive switching state. These load configurations will result in phase voltages of 0, ±15𝑉𝑑𝑐 ⁄,±25𝑉𝑑𝑐 ⁄,±35𝑉𝑑𝑐 ⁄,±45𝑉𝑑𝑐 ⁄, as shown in Fig. 2.6, depending on the number of windings connected to either the positive or the negative rail of the VSI {positive-negative}. + - + - + - - + - + n P N Vdc + -0Vdc {0-5} 0Vdc + - + - + - - + - + n P N Vdc + -1/5Vdc {1-4} 4/5Vdc + - + - + - - + - + n P N Vdc + -2/5Vdc {2-3} 3/5Vdc + - + - + - - + - + n P N Vdc + -0Vdc {5-0} 0Vdc + - + - + - - + - + n P N Vdc + -4/5Vdc {4-1} 1/5Vdc + - + - + - - + - + n P N Vdc + -3/5Vdc {3-2} 2/5Vdc Fig. 2.6.: Five-phase two-level drive load configuration scheme.
Multiphase Drives: Generalities, Modeling and Control 22 -1 -0.5 0 0.5 1 -1 -0.8 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 0.8 1 0,31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 -1 -0.5 0 0.5 1 -1 -0.8 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 0.8 1 0,31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 a – b x–y Fig. 2.7.: Space Vector Diagrams in the 𝜶–𝜷 (left side) and 𝒙–𝒚 (right side) planes. The two-level five-phase VSI allows 25=32 voltage vectors (30 active and 2 zero), which are mapped in the 𝛼-𝛽 and 𝑥-𝑦 subspaces (Fig. 2.7), applying the Clarke transformation matrix (26) to the stator phase voltage matrix in (96). Each vector is identified using the decimal number corresponding to the binary code of the switching state of each pair of IGBT’s [𝑆𝑎;𝑆𝑏;𝑆𝑐;𝑆𝑑;𝑆𝑒]. Due to the machines winding configuration, the harmonic components of order 5𝑛, are eliminated. However harmonics of order (10𝑛+1), (10𝑛+3), (10𝑛+7) and (10𝑛+9) with 𝑛=0,1,2,3,4,5, will still appear in the harmonic spectrum. Those harmonic components that contribute to the electromechanical energy conversion are mapped in the 𝛼-𝛽 plane, while the components that do not generate electrical torque are mapped in the 𝑥-𝑦 plane. Summarizing, the harmonic spectrum mapped in the 𝛼,𝛽,𝑥,𝑦 will be: 𝛼-𝛽 Plane: Harmonic components of order 10𝑛±1. 𝑥-𝑦 Plane: Harmonic components of order 10𝑛±3. 𝑧 Plane: Harmonic components of order 5𝑛. Notice in Fig. 2.7, that the 30 active voltage vectors can be subdivided in three sets of ten vectors namely, large (in black color), medium (in red color) and small (in blue color). Moreover, observe that the large vectors in the 𝛼-𝛽 plane are mapped as small vectors in the 𝑥-𝑦 plane, the medium voltage vectors in the 𝛼-𝛽 plane are also the medium vectors in the 𝑥-𝑦 plane and finally, that the small vectors in the 𝛼-𝛽 plane are mapped as large vectors in the 𝑥-𝑦 plane. Depending on the multiphase drive point of operation, the stator voltage applied to the machine can vary. This stator
Chapter 2 23 voltage vector must be selected according to the desired value in the 𝛼-𝛽 plane (required electrical torque) without a high increment of the applied component in the 𝑥-𝑦 plane, which will increase undesired electromagnetic losses. The common-mode voltage (CMV) relates the motor neutral voltage to the mid-point of the DC-Link [56], as shown in Fig. 2.1, marked as 𝑉𝐶𝑀. The expression of the CMV in a five-phase drive is: 𝑉𝐶𝑀=𝑉𝑑𝑐 5(𝑆𝑎+𝑆𝑏+𝑆𝑐+𝑆𝑑+𝑆𝑒)−𝑉𝑑𝑐 2 (97) Notice from (97) that the maximum peak value of the common-mode voltage in a five-phase drive is |𝑉𝐶𝑀|=𝑉𝑑𝑐 2 ⁄, the minimum voltage variation is ±𝑉𝑑𝑐 5 ⁄ and that there are three different possible voltage levels. Notice also that even though the five-phase drive is based on a two-level VSI, the resultant CMV is multilevel as a consequence of the number of switching states. Considering the possible switching combinations in (97), there are six different sets of common-mode voltage values [56], that can be divided depending on the magnitude of the CMV generated in the a - b subspace [9]: Small CMV (±0.1𝑉𝑑𝑐): Given by switching state combinations resulting in {2-3} or {3- 2} load configurations (Fig. 2.6). Medium CMV (±0.3𝑉𝑑𝑐): Given by switching state combinations resulting in {1-4} or {4- 1} load configurations (Fig. 2.6). Large CMV (±0.5𝑉𝑑𝑐): Given by switching state combinations resulting in {0-5} or {5- 0} load configurations (Fig. 2.6). 2.3 STANDARD CONTROL TECHNIQUES Multiphase drives control schemes are based mainly on the extension of traditional control techniques originally proposed for three-phase machines, implementing linear and nonlinear regulators such as Proportional Integral (PI) and hysteresis controllers. Proposed control techniques effectively exploit the additional degrees of freedom that multiphase drives possess, ensuring fast response to changes on the velocity and torque references, while maintaining the electrical drive within its maximum current rating. In this way Field Oriented Control (FOC) technique, originally founded in the literature for the three-phase case [57, 58, 59], based on PI and hysteresis controllers, has been extended for the multiphase case [60], successfully decoupling torque and flux control, regardless of the number of phases of the multiphase drive. This is also the case of the Direct Torque
Multiphase Drives: Generalities, Modeling and Control 24 Control (DTC), based on hysteresis regulators proposed for the three-phase case in [61], and extended to the five-phase induction machine in [62]. 2.3.1 FIELD ORIENTED CONTROL Among the control techniques found in the literature, field oriented control or Vector Control, is probably the most widely used in industrial applications. It is based on independently controlling torque and flux production in the decoupled rotating reference frame (𝑑-𝑞), obtained through Clarke- Park transformations, with the 𝑑-axis aligned to the air-gap, stator or rotor flux component [63]. Regardless to which component the 𝑑-axis is aligned to, the controller is based on eliminating the 𝑞– stator or rotor flux component in the electromagnetic torque equation (88)-(89), in order to ensure that torque production is controlled only by stator flux and current (88) or rotor flux and stator current (89). Notice that the proper selection to which flux the rotating reference frame is aligned to, results in control scheme simplifications. For instance, if the rotating reference frame is aligned to the airgap flux, proper control of the 𝑞component must be provided in order to maintain it at zero. On the other hand if the stator flux is selected both stator flux and current must be controlled resulting in a much complex control scheme than when rotor flux is implemented where rotor flux and stator currents are independently controlled by 𝑑- and 𝑞components, respectively. As a result Rotor Field Oriented Control (RFOC) is the most widely used among FOC strategies in industry application [9]. There are two RFOC strategies found in the literature namely, the Indirect Rotor Flux Oriented Control (IRFOC) and the Direct Field Oriented Control (DRFOC). Being the main difference between both methods, the way in which the rotor flux angular position is obtained. When the RFOC is implemented the rotor flux in the 𝑞-axis is null (Fig. 2.8), and the rotor currents can be obtained through the rotor flux equations as follows: 𝜆𝑟𝑑=(𝐿𝑙𝑟+𝐿𝑚)𝑖𝑟𝑑+𝐿𝑚𝑖𝑠𝑑→𝑖𝑟𝑑=1 𝐿𝑟(𝜆𝑟𝑑−𝐿𝑚𝑖𝑠𝑑) (98) 𝜆𝑟𝑞=0=(𝐿𝑙𝑟+𝐿𝑚)𝑖𝑟𝑞+𝐿𝑚𝑖𝑠𝑞→𝑖𝑟𝑞=−𝐿𝑚 𝐿𝑟𝑖𝑠𝑞=−𝑘𝑟𝑖𝑠𝑞 (99) Substituting the rotor currents (98)-(99) in the 𝑑-𝑞 reference frame voltage equations in (86), the machine modeling equations take the following form: 𝜆𝑟𝑑+𝜏𝑟𝑑 𝑑𝑡𝜆𝑟𝑑=𝐿𝑚𝑖𝑠𝑑 (100) 𝜔𝑠𝑙𝜏𝑟𝜆𝑟𝑑=𝐿𝑚𝑖𝑠𝑞 (101)
Chapter 2 31 + - w *m +- PI STATOR VOLTAGE ESTIMATOR FLUX ESTIMATOR TORQUE ESTIMATOR iabcd is(k) abcd TO ab xyz λ*s λs w m is a is b isx Vdc λs isy isz LOOKUP TABLE + - Te Te is(k) Si FLUX POSITION ab Si LOOKUP TABLE FLUX POSITION xy Gi 5 T*e Fig. 2.11.: Modified DTC scheme with two lookup tables for five-phase drive. + - w *m +- PI V[k] STATOR VOLTAGE ESTIMATOR FLUX ESTIMATOR TORQUE ESTIMATOR PWM iabcd is(k) abcd TO ab xyz λ*s λs w m is a is b isx Vdc λs isy isz LOOKUP TABLE + - Te Te is(k) V[k] q s 5 Si P T*e - + w th w r w m Fig. 2.12.: Modified DTC scheme with virtual vector lookup table for five-phase drive. More recently, modified schemes have been proposed including new capabilities to traditional DTC such as sensorless drive control [80], where only phase currents and DC-Link voltage are measured in order to calculate the stator flux position and load angle, necessary to estimate the machines position and speed, achieving speed sensorless operation. Correspondingly, research presented in [40], also achieves speed sensorless operation, while avoiding the demagnetizing effect at low speed operation and eliminating low frequency current harmonics, through the inclusion of ten virtual voltage vectors in a modified lookup table, increasing control capabilities. Finally, based on
Multiphase Drives: Generalities, Modeling and Control 32 the virtual voltage vectors proposed in [40], a DTC with common-mode voltage reduction capability is proposed in [81], Fig. 2.12, where the additional virtual voltage vectors are selected in order to avoid zero voltage vectors. 2.4 PREDICTIVE CONTROL Predictive controllers can be defined as any algorithm that is based on the model of the controlled system to predict its future behavior and selects the most suitable control action in order to correctly follow the control criteria. Different predictive controllers are available in the literature and have been thoroughly studied in [82, 83], presenting the general subdivision shown in Fig. 2.13. Further on, depending on their operating principle, available techniques have been classified into classical predictive control and Finite-Control Set Model-Based Predictive Control (FCS-MPC) [84]. Predictive Control Techniques Deadbeat Hysteresis Trajectory Model Predictive Control - Modulation Scheme - Fixed Switching Frequency - Low Computation Cost - Constraints Not Included - No Modulation Scheme - Variable Switching Frequency - Simple Implementation - No Modulation Scheme - Variable Switching Frequency - No cascaded structure - Modulation Scheme - Fixed Switching Frequency - Constraints can be Included Continuous Control Set Finite-Control Set - No Modulation Scheme - Variable Switching Frequency - High Computation Cost - Online Optimization - Constraints can be Included Fig. 2.13.: Predictive control methods. Deadbeat Predictive Control (DBPC) is classified as a classical predictive controller and is based on an accurate model of the system to estimate the required voltage to achieve the reference value of the controlled variable. The required reference voltage is imposed to the electrical drive through modulation strategies, thus operating with a fixed switching frequency. This is one of the main differences between DBPC and hysteresis, trajectory and FCS-MPC strategies. This scheme has been applied for three- and fivephase drives in [85, 86, 87, 88]. Hysteresis Predictive Control (HPC), also classified as a classical controller, is based on maintaining the control variables between predefined boundaries, given by the hysteresis regulator. When the controlled variable reaches the limit of the control boundary, a new switching state is determined, by predicting the time intervals required in order for the controlled vector to reach the hysteresis boundary [82].
Chapter 2 33 Trajectory Predictive Control (TPC) techniques consist on forcing the controlled variables to follow a pre-calculated trajectory, by applying a pre-defined set of switching states, classified depending on the effect they have on the electrical drive, either increasing or decreasing torque production, as presented in [89], where Direct Self Control (DSC) is developed for a three-phase drive. Model Predictive Control (MPC) consists of an accurate model of the system that is used to predict the future behavior of the state variables through time, depending on the applied voltage vector. Each sampling period an error between the controlled variables and the ones predicted in the model are evaluated in a cost function. The switching state that ensures a lower cost function is selected to be applied during the next cycle. Among the benefits of MPC control is the capability to include systems nonlinearities and consider at the same time different constraints, such as current ratings, common-mode voltage and low order harmonics reduction. On the other hand, the main drawback of MPC is the high amount of calculations needed in order to solve the optimization problem online. This limits the implementation because sampling times must be big enough in order to ensure proper algorithm calculation. In order to compensate this drawback, three different modifications to the traditional MPC have been presented in the literature: A. Solving the optimization problem off-line: Implementing the MPC online as a search tree, consequently reducing the time needed by the controller to select a proper control action [90]. B. Generalized Predictive Control (GPC): A linear controller is obtained by solving the optimization problem analytically. However this makes the inclusion of systems nonlinearities and different constraints in the basic MPC much more difficult [91]. C. Finite-Control Set Model-Based Predictive Control (FCS-MPC): Based on the discrete/finite number of switching states of the power converters. The optimization problem is reduced to the estimation of the electrical drive behavior due to available switching states, selecting the switching state that minimizes the implemented cost function [92]. The present doctoral thesis presents a novel fault-tolerant control strategy based on FCS-MPC techniques. Consequently the following literature review is based solely on FCS-MPC control techniques.
Multiphase Drives: Generalities, Modeling and Control 34 2.4.1 FINITE-CONTROL SET MODEL-BASED PREDICTIVE CONTROL FCS-MPC techniques [92], have become an interesting alternative to the standard FOC and DTC approaches in the development of high-performance three- and multiphase drives [29, 41, 84, 93], and have been proposed with different types of power converters [94, 95]. The basic scheme of FCS-MPC is presented in Fig. 2.14. In this case in order to present a simple FCS-MPC, the external control loop is neglected, however depending on the implemented external loop, current references are provided by speed and flux controllers. Notations is(k): measured stator currents. îs(k+1): predicted stator currents. is*(k): reference stator currents. Sij(k+1): One of the possible switching voltage vector. Sioptimum(k+1): Switching voltage vector that minimices J. iabcd is(k) abcd TO ab xyz is a is b isx isy isz 5 Sioptimum(k+1) Sij(k+1) COST FUNCTION SEQUENCER j=1...N J is(k) i*s(k) îs(k+1) Vdc POSSIBLE VOLTAGE VECTORS PREDICTIVE MODEL MINIMIZER FUNCTION Min(J) i*abcd abcd TO ab xyz i*s a i*s b i*sx i*sy i*s(k) Fig. 2.14.: Finite-Control Set Model-Based Predictive Control scheme. Every sampling period, the reference (𝑖𝑠∗(𝑘)) and measured phase currents (𝑖𝑠(𝑘)) are mapped in the stationary reference frame. Then, the machine state-space model is used, to predict current evolution (𝑖𝑠(𝑘+1)), depending on the different possible switching states (𝑆𝑖𝑗(𝑘+1)) and considering the VSI DC-Link voltage and measured phase currents (𝑖𝑠(𝑘)). Subsequently, a cost function (𝐽) is evaluated, considering each predicted current and the reference current (𝑖𝑠∗(𝑘)). Finally, the switching vector that provides the lowest value of the cost function (𝐽), is applied to the power converter during the next sampling period (𝑆𝑖𝑜𝑝𝑡𝑖𝑚𝑢𝑚(𝑘+1)). This process is depicted in the flow
Chapter 2 35 diagram in Fig. 2.15. Start Assign initial values Jo , j 1 While j N Take Sij Use the predictive model to compute a prediction of the stator current for the next sampling period. Compute the cost function J. If J< Jo Jo J, Sioptimum(k+1) Sij Increment counter j Compute stator voltages corresponding to gating signal combination Sij using the predictive model End YES NO Fig. 2.15.: FCS-MPC flow diagram. Notice that different cost functions (114) can be defined depending on the specific application in order to include different control constraints (𝐶𝑖). For instance in a conventional FCS-MPC current controller, the cost function may only depend on the reference and predicted currents in the stationary reference frame, however when a FCS-MPC torque control is implemented, the cost function is defined not only by predicted current but also by predicted torque and flux. Furthermore, different control criteria aimed to optimize the multiphase drive performance, such as DC-Link voltage balancing, switching stress minimization, common-mode voltage reduction and stator current
Multiphase Drives: Generalities, Modeling and Control 36 harmonic minimization, can be included. Each of the constraints considered in the cost function can be assigned a different degree of importance on the overall controller objective, through the proper definition of weight factors (𝑊𝑖). Being this one of the advantages of FCS-MPC, where different constraints can be considered without an increase in its implementation complexity. 𝐽=𝑊1𝐶1+𝑊2𝐶2+⋯+𝑊𝑖𝐶𝑖 (114) FCS-MPC can be classified in two categories depending on the prediction horizon (𝑁𝑝) they implement, in either large or short prediction horizon [84]. Prediction horizon can be defined as the number of future states in time that the controller predicts in order to select the most suitable control action. Short prediction horizon is defined as (𝑁𝑝=1), where measured variables are determined in the instant (𝑘), then the optimum switching state is calculated for (𝑘+1) and applied at (𝑘+1). On the other hand large prediction horizon (𝑁𝑝≥2), further predict the behavior of the electrical drive for future instants (𝑘+2,𝑘+3…) and selects the optimum VSI switching state to be applied on (𝑘+ 1), respectively (Fig. 2.16). It has been demonstrated that larger prediction horizon results in better performance [95], however the increase in the prediction horizon, results in higher computational costs making its implementation not suitable [96]. Notice that FCS-MPC does not provide a fixed switching frequency, due to the fact that it does not necessarily apply a switching vector to the VSI each sampling period. t(k) Ts t(k+1) t(k+2) Ts Ci C*i S1 Sn S2 Sioptimum S1 Sn S2 Sioptimum Fig. 2.16.: FCS-MPC prediction horizon principle. In order to implement the FCS-MPC in a Digital Signal Processor (DSP), the machine modeling equations must be represented in a discrete-time state-space form [97, 98]. In this case the
Chapter 2 37 stator phase currents and rotor flux, in the stationary reference frame, are assumed as state variables [97]. As a result the machine modeling equations can be expressed as: 𝑑 𝑑𝑡𝑖𝑠𝛼𝛽 =−(1 𝜎𝜏𝑠−1−𝜎 𝜎𝜏𝑟)𝑖𝑠𝛼𝛽 +1−𝜎 𝜎𝜏𝑟𝐿𝑚𝜆𝑟𝛼𝛽 −1−𝜎 𝜎𝐿𝑚𝜔𝑟𝜆𝑟𝛼𝛽 +1 𝜎𝐿𝑠𝑣𝑠𝛼𝛽 (115) 𝑑 𝑑𝑡𝑖𝑠𝑥𝑦 =−1 𝜏𝑙𝑠𝑖𝑠𝑥𝑦 +1 𝐿𝑙𝑠𝑣𝑠𝑥𝑦 (116) 𝑑 𝑑𝑡𝑖𝑠𝑧 =−1 𝜏𝑙𝑠𝑖𝑠𝑧 +1 𝐿𝑙𝑠𝑣𝑠𝑧 (117) 𝑑 𝑑𝑡𝜆𝑟𝛼𝛽 =𝐿𝑚 𝜏𝑟𝑖𝑠𝛼𝛽 −1 𝜏𝑟𝜆𝑟𝛼𝛽 −𝑗𝜔𝑟𝜆𝑟𝛼𝛽 (118) 𝜆𝑠𝛼𝛽 =𝜎𝐿𝑠𝑖𝑠𝛼𝛽 +𝑘𝑟𝜆𝑟𝛼𝛽 (119) Being 𝑘𝑟, 𝜏𝑟, 𝜎, 𝜏𝑠 and 𝜏𝑙𝑠 as defined in (102), (103), (110), (120) and (121), respectively. 𝜏𝑠=𝐿𝑠 𝑅𝑠 (120) 𝜏𝑙𝑠=𝐿𝑙𝑠 𝑅𝑠 (121) Rewriting (115)-(119) in terms of their real and imaginary components in matrix form: 𝑑 𝑑𝑡[𝑥]=[𝐴][𝑥]+[𝐵][𝑢] (122) [𝑦]=[𝐶][𝑥] (123) where: [𝑥]=[𝑖𝑠𝛼 𝑖𝑠𝛽 𝑖𝑠𝑥 𝑖𝑠𝑦 𝑖𝑠𝑧 𝜆𝑟𝛼 𝜆𝑟𝛽]𝑇 (124) [𝑢]=[𝑣𝑠𝛼 𝑣𝑠𝛽 𝑣𝑠𝑥 𝑣𝑠𝑦 𝑣𝑠𝑧 ]𝑇 (125) [𝑦]=[𝜆𝑠𝛼 𝜆𝑠𝛽]𝑇 (126) [𝐴]= [ −(1 𝜎𝜏𝑠−1−𝜎 𝜎𝜏𝑟) 0 0 0 0 1−𝜎 𝜎𝜏𝑟𝐿𝑚1−𝜎 𝜎𝐿𝑚𝜔𝑟 0 −(1 𝜎𝜏𝑠−1−𝜎 𝜎𝜏𝑟) 0 0 0 −1−𝜎 𝜎𝐿𝑚𝜔𝑟1−𝜎 𝜎𝜏𝑟𝐿𝑚 0 0 −1 𝜏𝑙𝑠 0 0 0 0 0 0 0 −1 𝜏𝑙𝑠 0 0 0 0 0 0 0 −1 𝜏𝑙𝑠 0 0 𝐿𝑚 𝜏𝑟0 0 0 0 −1 𝜏𝑟−𝜔𝑟 0𝐿𝑚 𝜏𝑟0 0 0 𝜔𝑟−1 𝜏𝑟 ] (127)
Multiphase Drives: Generalities, Modeling and Control 38 [𝐵]= [ 1 𝜎𝐿𝑠0 0 0 0 01 𝜎𝐿𝑠0 0 0 0 0 1 𝐿𝑙𝑠 0 0 0 0 0 1 𝐿𝑙𝑠 0 0 0 0 0 1 𝐿𝑙𝑠 0 0 0 0 0 0 0 0 0 0 ] (128) [𝐶]=[𝜎𝐿𝑠0 0 0 0 𝑘𝑟0 0𝜎𝐿𝑠0 0 0 0 𝑘𝑟] (129) Notice in (127) that matrix [𝐴] has components that depend on the instantaneous value of the mechanical speed (𝜔𝑚) and consequently it is not possible to calculate all its terms off-line. However it is possible to divide matrix [𝐴] into a constant matrix [𝐴𝑐] and a speed dependent [𝐴𝜔] matrix, allowing to estimate off-line all matrix [𝐴] constant components and online only those components dependent on the mechanical speed, as follows: [𝐴]=[𝐴𝑐]+[𝐴𝜔] (130) Next, the machine state-space equations (122)-(123) are discretized with a sample period (𝑇𝑠), assuming constant input and constant matrices during the whole sampling period [98]: 𝑥[𝑘+1]=[Φ]𝑥[𝑘]+[Γ]𝑢[𝑘] (131) 𝑦[𝑘+1]=[𝐶]𝑥[𝑘+1] (132) [Φ]=𝑒[𝐴]𝑇𝑠=𝑒([𝐴𝑐]+[𝐴𝜔])𝑇𝑠=𝑒[𝐴𝑐]𝑇𝑠∙𝑒[𝐴𝜔]𝑇𝑠 (133) [Γ]=∫𝑒[𝐴]𝜏 𝑇𝑠 0[𝐵]𝑑𝜏=𝑒[𝐴𝑐]𝑇𝑠[𝐵]𝑇𝑠 (134) Consequently matrix [Φ], consists of a constant term (𝑒[𝐴𝑐]𝑇𝑠), calculated off-line and a time varying term (𝑒[𝐴𝜔]𝑇𝑠), which by applying the Cayley-Hamilton theorem, can be defined as [98]: 𝑒[𝐴𝜔]𝑇𝑠= [ 1 0 0 0 0 𝐿𝑚1−𝑐𝑜𝑠 (𝜔𝑟𝑇𝑠) 𝜎𝐿𝑠𝐿𝑟𝐿𝑚𝑠𝑖𝑛 (𝜔𝑟𝑇𝑠) 𝜎𝐿𝑠𝐿𝑟 0 1 0 0 0 −𝐿𝑚𝑠𝑖𝑛 (𝜔𝑟𝑇𝑠) 𝜎𝐿𝑠𝐿𝑟𝐿𝑚1−𝑐𝑜𝑠 (𝜔𝑟𝑇𝑠) 𝜎𝐿𝑠𝐿𝑟 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 𝑐𝑜𝑠 (𝜔𝑟𝑇𝑠) −𝑠𝑖𝑛 (𝜔𝑟𝑇𝑠) 0 0 0 0 0 𝑠𝑖𝑛 (𝜔𝑟𝑇𝑠) 𝑐𝑜𝑠 (𝜔𝑟𝑇𝑠) ] (135)
Chapter 2 39 In the following subsections some of the FCS-MPC schemes implemented in multiphase drives will be presented. Notice that the proposed techniques are based on fast inner FCS-MPC controllers with outer slower PI regulators, offering higher control bandwidth compared with cascaded PI controllers [84]. 2.4.1.1 PREDICTIVE CURRENT CONTROL Predictive Current Control (PCC) based on FCS-MPC uses only the predicted stator currents in the stationary reference frame in order to control the multiphase drive. Current references are obtained in the rotating reference frame, from an outer PI based speed control loop and a constant 𝑑component current and then mapped in the stationary reference frame in order to be used in the cost function, as shown in Fig. 2.17. This simple predictive controller scheme has been implemented in multiphase drives, with different number of windings, neutral points and power converters [29, 30, 41]. + - PI dq ab abcd TO ab xyz POSITION ESTIMATOR q iabcd is b w *m w m is a isx isy i*s a i*s b i*sx i*sy i*sd i*sq i*sd i*sq is(k) 5 Sioptimum(k+1) Sij(k+1) COST FUNCTION SEQUENCER j=1...N J i*s(k) îs(k+1) Vdc POSSIBLE VOLTAGE VECTORS PREDICTIVE MODEL MINIMIZER FUNCTION Min(J) w m is(k) Fig. 2.17.: FCS-MPC based Predictive Current Control with an outer speed control loop. The overall control aim is to generate a desired electric torque which implies sinusoidal stator current references in 𝑎-𝑏-𝑐-𝑑-𝑒 phase coordinates. In the stationary a - b -𝑥-𝑦 reference frame, the control aim is traduced into a reference stator current vector in the 𝛼-𝛽 plane, which is constant in magnitude but changing its electrical angle following a circular trajectory, and depending on the implemented multiphase machine, either null or non-null reference stator current vector in the 𝑥-𝑦 plane. For instance, if a five-phase machine with distributed windings is implemented, the 𝛼-𝛽 stator
Multiphase Drives: Generalities, Modeling and Control 40 current components contribute to torque production while 𝑥-𝑦 stator current components do not, thus a zero reference is set for the 𝑥-𝑦 current components. The weight factors in the cost function (136) are adjusted in order to favor those switching states (32, for a five-phase two-level VSI), that maximize 𝛼-𝛽 currents and at the same time provide minimum 𝑥-𝑦 currents. 𝐽=𝐴|𝑖𝑠𝛼 |+𝐵|𝑖𝑠𝛽 |+𝐶|𝑖𝑠𝑥 |+𝐷|𝑖𝑠𝑦 | (136) where each 𝛼-𝛽-𝑥-𝑦 current term is defined as: 𝑖𝑠𝛼 =𝑖𝑠𝛼 ∗(𝑘+1)−𝑖𝑠𝛼(𝑘+1),𝑖𝑠𝛽 =𝑖𝑠𝛽 ∗(𝑘+1)−𝑖𝑠𝛽(𝑘+1) (137) 𝑖𝑠𝑥 =𝑖𝑠𝑥 ∗(𝑘+1)−𝑖𝑠𝑥(𝑘+1),𝑖𝑠𝑦 =𝑖𝑠𝑦 ∗(𝑘+1)−𝑖𝑠𝑦(𝑘+1) (138) In [41], a predictive current controller in the rotating reference frame was implemented for a five-phase two-level induction motor drive with a modified cost function (139) and its performance was compared against an IRFOC, in different operating points. In this case a weight factor has only been provided for x-y currents in order to favor currents produced in the d-q plane. It was concluded that the PCC controller provided better transient state performance and low order harmonic minimization, while the IRFOC ensured better steady-state operation and offered lower phase current ripple regardless of the operating frequency, at the expense of higher switching stress. 𝐽=𝑖𝑠𝑑 +𝑖𝑠𝑞 +𝑊𝑥𝑦[𝑖𝑠𝑥𝑦 ] (139) where each 𝑑-𝑞-𝑥-𝑦 current term is defined as: 𝑖𝑠𝑑 =(𝑖𝑠𝑑 ∗(𝑘+2)−𝑖𝑠𝑑(𝑘+2))2,𝑖𝑠𝑞 =(𝑖𝑠𝑞 ∗(𝑘+2)−𝑖𝑠𝑞(𝑘+2))2 (140) 𝑖𝑠𝑥𝑦 =[(𝑖𝑠𝑥 ∗(𝑘+2)−𝑖𝑠𝑥(𝑘+2))2+(𝑖𝑠𝑦 ∗(𝑘+2)−𝑖𝑠𝑦(𝑘+2))2] (141) 2.4.1.2 PREDICTIVE TORQUE CONTROL The general scheme of the Predictive Torque Control (PTC) based on FCS-MPC for fivephase two-level induction motor drives presented in [42] is shown in Fig. 2.18. It is formed by an outer PI based speed control and an inner PTC, whose controlled variables are the stator flux and the produced torque. The basic PTC cost function is defined as in (142), where (𝑇𝑛2) and (𝜆𝑠𝑛 2) represent the weight factor of torque and stator flux components and their value corresponds to their rated values at base speed operation. In order to improve PTC performance in [42] a modified cost function was presented, aimed to not only control stator flux and produced torque but also limit the maximum
Chapter 2 47 due to the drive operation under overload and unbalanced load conditions, electromagnetic stress, manufacturing problems, dynamic stress from shaft torque, environmental conditions and fatigued mechanical parts [110, 111]. 2.5.1.3 ECCENTRICITY FAULTS Eccentricity is caused by manufacturing and constructive errors that cause an unequal air gap between the stator and the rotor, leading to unbalanced radial forces and possible rotor-stator contact [110]. Eccentricity can be further classified as static (where the position of the air gap inequality is fixed) and dynamic (where the rotor center is not properly aligned at the rotation center and the position of the air gap inequality rotates). Eccentricity detection methods are mostly based on phase current and vibration analysis [110, 121, 122]. 2.5.1.4 BEARING FAULTS Bearing faults are mainly caused by assembling errors, where the bearings may be misaligned or forced into the shaft/housing. This results in bearing vibration and may be detected by the machines phase currents analysis [121]. 2.5.1.5 BENT SHAFT FAULTS Bent shaft faults are similar to dynamic eccentricity faults [110], and are mainly due to force unbalance or machine-load misalignment, resulting on machine vibration and further machine failure [111]. 2.5.2 SENSOR FAULTS Speed, DC-Link voltage and current sensors are commonly used in electrical drives for control and protection purposes (Fig. 2.20). Such is the case of FOC and predictive techniques where speed and at least two (for a three-phase drive) and four (for a five-phase drive) current measurements are needed in order to ensure proper control behavior. In case of faulty sensor operation, inexistent, noisy or deviated measured signals can downgrade the system performance or result in a complete drive failure [123, 124, 125, 126]. Sensor faults have been mainly analyzed for three-phase drives and recent work has addressed this type of fault for the multiphase case [80, 127, 128]. The following reviewed articles consider also the three-phase case as a mean to present this type of fault, which depending on
Multiphase Drives: Generalities, Modeling and Control 48 the faulty sensor (i.e. DC-Link voltage, current or speed), may have the same effect in drives with higher number of phases. Research has been mainly focused on handling only one faulty sensor due to the small probability of more than one sensor fault [129]. Post-fault operation techniques after sensor faults, are commonly based on switching between different control techniques depending on the type of sensor fault, reconfiguring from a closed-loop control to an open-loop strategy [130, 131, 132, 133, 134, 135], downgrading the electrical drive dynamic performance, or on implementing different independent observers, for either DC voltage, phase current or speed and maintaining closed-loop control operation [123, 132]. For instance, when a voltage sensor fault occurs its effect results, regardless of the number of drive phases, on either a very small or much higher voltage measurement with respect to the expected value. This is of special importance in electric vehicle applications where the DC-Link voltage is constantly changing and an accurate measure is needed [136]. Proposed techniques for DC-Link voltage estimation, susceptible of implementation in the multiphase case, are based on the modulation index and estimated phase voltage [123]. Current sensor faults are among the most critical faults in electrical drive applications. This is due to the fact that most closed-loop control techniques are based on current measurement and consequently any variation on the measured current may result in instantaneous power demanding control actions, leading the whole system to possible electrical stress. Current sensor faults are most commonly detected and handled by estimating the expected current values, based on the machines electrical parameters, Luenberger observers based on the remaining current sensor information and on adaptive and extended Kalman filters [123, 126, 129, 137, 138, 139, 140, 141], which can be extended to multiphase drives. Similar to current sensor faults, speed sensor faults affect closed-loop speed control techniques leading to rotor field disorientation and power demanding control actions imposed by the controller aiming to maintain the speed reference [123]. These types of faults are mainly due to vibration and temperature issues and are effectively detected and handled, in the three-phase case, by using speed estimation techniques based on Luenberger observers and extended Kalman filters [126, 142, 143, 144]. Regarding multiphase drives, speed sensorless operation has been analyzed in a five-phase drive under normal operation with a DTC scheme [80], estimating the rotor speed/position based on the position of the stator flux linkages and under an open-phase fault [128], implementing a FOC scheme
Chapter 2 49 with proportional-resonant controllers and estimating the machine speed using a rotor flux-based model reference adaptive system. 2.5.3 POWER CONVERTER FAULTS Power converter faults are among the most non-predictable and common types of faults of industrial electrical drives [145]. These types of faults are mainly due to the semiconductor driver failure, leaving the semiconductor either in constant ON or OFF state or to the burn out of the semiconductor. Power converter faults are presented graphically in Fig. 2.20, and can be classified as [102]: 1. Single short-circuit switch fault. 2. Single open-circuit switch fault. 3. Phase-leg short-circuit fault. 4. Phase-leg open-circuit fault. 5. Open-circuit line fault. These faults may lead the converter to either lose a complete phase (also termed open-phase fault) or to physically maintain the number of phases and current flow, but to lose specific control capabilities on either one or both of the semiconductor of a certain phase. As a result, it is possible to expect that the configuration of the electrical drive vary and that the post-fault electrical drive may be regarded as an entire different system [146]. As it has been stated in numerous previous works, the phase redundancy that multiphase drives possess allows managing faulty operation, depending on the specific electrical machine configuration, without the need of extra equipment. This holds true for any kind of open-circuit and short-circuit faults, where proposed post-fault control techniques exploit the extra degrees of freedom the faulty converter possess when compared to conventional three-phase converters. Depending on the type of fault and the specific electrical drive topology, different post-fault control strategies, drive configuration and electrical machine winding connections are adopted for post-fault operation. For instance, the inclusion of auxiliary semiconductors in each or some phase windings was addressed in [147], in order to physically isolate the short-circuit faulty phase (i.e. changing from a short-circuit fault to an open-circuit or open-phase fault), and ensure ripple free output torque with the remaining four healthy phases. As a result, the electrical drive is able to manage different types of
Multiphase Drives: Generalities, Modeling and Control 50 faults, but at the expense of extra electronic equipment. On the other hand, in [148] short-circuit faults are managed in a five-phase drive by controlling the available four healthy phases, maintaining operation at the expense of higher stator phase windings losses and torque ripple. However in a dual three-phase drive [114], this increase in torque ripple, which is mainly due to the symmetric fault condition, can be properly managed by maintaining post-fault operation with one three-phase drive in short-circuit and compensate the braking torque with the healthy three-phase drive [149]. Different winding connections have been also considered for single and phase short circuit faults [150], for a dual three-phase machine, assessing the effect of the harmonics obtained in the machines losses and torque, and evaluating its performance under different working conditions. A similar approach has been followed for open-phase and open-line faults, where different drive topologies or machine winding connections have been considered. For instance, in [3] a sixphase drive was designed in order to independently control each phase of a three-phase machine under different types of faults and its viability was proved by emulating an open-circuit line fault. While the winding connections of a five-phase machine, considering penta- and startype winding, was compared in [44]. In this case, fundamental and third-harmonic components are used to control the post-fault operation of the electrical drive, increasing the available torque while reducing torque ripple and losses. It was concluded that penta-winding connection results in an improved fault-tolerance behavior because a higher number of open-circuit phases can be managed (up to a total of three openphase faults in a five-phase drive), a higher and smoother torque is produced, and even lower losses are obtained when certain types of faults appear. 2.5.4 FAULT-TOLERANT CONTROL TECHNIQUES Multiphase drive fault-tolerance is achievable through control reconfiguration considering the type of fault, its effect on the electrical drive and certain derating limits in order to ensure that postfault operation does not result in further drive damage. Regardless of the electrical machine type (either induction or permanent magnet), and number of phases, proper post-fault control exploits the additional degrees of freedom, by setting and controlling the x-y plane reference currents [106, 151], preserving the fundamental component of the air-gap magnetic field and ensuring circular flux trajectory [44, 105, 106], [150]-[152]. The number of degrees of freedom available for post-fault operation control purposes, depends not only on the type of fault, electrical machine and power converter configuration, but also on the
Chapter 2 51 number of healthy phases, type of winding connection (star-type, penta-type) and isolated neutral points. For instance, a comparative study was presented in [153], where a six-phase machine with both single and double neutral points where used, demonstrating that in case of a single neutral point, the controller possessed an extra degree of control freedom, when compared to the same machine with two isolated neutrals. Different control criteria can be achieved, depending on the selected x-y current references namely, minimum drive derating [151, 154], minimum copper losses [150, 151, 154, 155, 156] and minimum torque ripple or torque enhancement by third current harmonic injection [150, 157]. Proposed post-fault control techniques are mainly based on FOC strategies with an outer speed or torque control loop and an inner current controller, implementing hysteresis [13, 76, 104], synchronous frame current control with feed-forward compensation [154], and resonant [155, 156] controllers. An important remark which constitutes one of the contributions of this thesis work is that none of these contributions have proven the transition from pre- to post-fault situations and have only shown the post-fault performance of the electrical drive. 2.5.4.1 DRIVE DERATING Regardless of the type of fault, post-fault control is generally designed to maintain rated flux and ensure certain torque/speed capability and quality [102]. The electrical drive derating level, i.e. setting the electrical drive working condition bellow its rated or designed values, depends on the specific electrical machine and power converter type/ratings, winding connection, DC-Link voltage reserve, type of fault and desired post-fault operation [45, 153]. Drive derating can be achieved following different approaches [102]: 1. Reducing the machines operating point constraints, i.e. torque and/or speed references, and consequently the demanded voltages and currents, without necessarily ensuring that the electrical drive is working at its maximum post-fault capability. 2. Limiting the drives currents to its nominal RMS values. Lowering the amount of torque/speed available for post-fault operation, but aiming to maintain the electrical drive at its maximum achievable working point. 3. Allowing phase currents to be above pre-fault values (within the drives electrical limits), but maintaining copper losses at nominal working condition values.
Multiphase Drives: Generalities, Modeling and Control 52 4. Designing the electrical drive to withstand higher current and voltage ratings than the ones sustained in normal pre-fault operation. By overrating the electrical drive, no derating has to be considered under post-fault operation, however an increase on the overall costs is foreseeable. As can be expected, if the third approach is considered, the electrical drive derating will be lower than with the second approach. This was demonstrated in [115], on an eleven-phase induction machine under an open-phase fault, where the derating factor was 9% and 14%, respectively, with each approach, considering the same post-fault control technique and criteria. In case of following the second approach, the current through the available healthy phases is increased up to its maximum capability, while limiting joule losses or thermal stress and maintaining peak phase currents within the drive ratings [103]. This increase in the phase currents requires in turn higher phase voltages which will ultimately demand a higher DC-Link voltage for post-fault operation [158]. A common practice, when designing electrical drives, is to select the DC-Link voltage rating depending on the electrical machines maximum phase voltage. If the electrical drive is designed considering only nominal and/or pre-fault conditions, the electrical drive must be derated [159], in order to maintain its operation within its electrical limits (reducing the achievable torque/speed), while avoiding overmodulation [160, 161] and voltage unbalance [162]. On the other hand, it is possible to maintain pre-fault operating conditions or to reduce the electrical drive derating by considering a proper DC-Link voltage reserve and overrating the electrical components for post-fault operation during the design stage. However, this results in extra costs and it is assumed, for some cases at the design stage, that a derating factor is a better option. For instance, as research presented in [158] suggests, the amount of DC-Link voltage reserved for ensuring proper post-fault operation depends on the electrical machine winding connection, being higher in starwinding than in pentagon-winding machines, accounting for approximately 12.5% and 8.5% for the star and pentagon machines, respectively. These percentages are considerably lower when compared to the overrating currents needed for post-fault operation of an electrical drive under single or double open-phase faults, which have been estimated as 38% in case of a single open-phase fault [151], and more than double for a two open-phase fault [163, 164, 165]. Nonetheless, drive overrating is not always a feasible option and is not adopted for withstanding short-circuit fault situations, where the machines currents must be limited to its maximum phase rated value due to the increased stator losses [149].
Chapter 2 53 Regarding the type of machine, it has been stated in [102, 153] that permanent magnet machines are capable of maintaining less post-fault derating than induction machines due to the fact that for induction machines, the magnetization and torque production are limited by the maximum achievable d and q current components, while in permanent magnet machines, the maximum phase current does not affect the machines magnetization and torque production varies linearly with the available q-current component. Nonetheless, it has been demonstrated that by considering current harmonic injection techniques along with different post-fault control criteria [157], between 55% and 74.3% of nominal torque is achievable with zero torque ripple in a five-phase permanent magnet machine under an open-phase fault. A similar case is observed when different types of winding connections are used, exploiting the fact that an odd n-phase machine allows (n+1)/2 winding connections. For instance, it was experimentally verified in [45, 164] that pentagon winding connections offered better post-fault performance, with lower drive derating, higher average torque with lower ripple and higher efficiency than traditional star winding connections. Moreover, it was demonstrated in [153] that star winding connections with single isolated neutral offer higher torque capability (between 47% and 66% of the nominal pre-fault torque, depending on the post-fault criteria) and copper loss minimization than star winding machines with two isolated neutral points. However, if the electrical drive is designed for restrictive applications such as more electric aircrafts, where higher component redundancy is desired and the implementation of an electrical drive with isolated neutrals is mandatory [166, 167], the maximum post-fault achievable torque would be about 43% of the pre-fault nominal torque, by operating the electrical drive under minimum copper loss criteria with the whole faulty converter disconnected, also termed “single VSC” operation [102, 153]. 2.5.4.2 POST-FAULT MACHINE MODELING As it can be observed in Fig. 2.20, the electrical drive configuration is changed after the fault occurrence and consequently the drive model must be revised for control and current reference calculation purposes. Most of the available literature is focused on the drive model considering openphase faults, where the machines stator winding distribution becomes asymmetrical. As in pre-fault condition, two different approaches can be considered to model the electrical machine namely, phase variable model or VSD.
Multiphase Drives: Generalities, Modeling and Control 54 In the first case, the machines faulty phase or phases are accounted by considering the remaining healthy phases and their spatial distribution within the stator [102]. However, the VSD is preferred for control purposes in order to simplify the machines model and its control implementation. In this case the Clarke transformation (26) used in pre-fault no longer results in independent planes, and depending on the type of fault one or more control degrees of freedom are lost. In consequence, the post-fault current controller must be designed considering the interdependence of the remaining phase currents [155, 156, 153]. On the other hand, a detailed description of the asymmetrical behavior of the electrical machine and the use of reduced order transformation matrices (orthogonal and nonorthogonal), where presented in [154, 168, 169], maintaining the currents and voltages components equal to the available degrees of freedom, thus simplifying the control implementation. In the case of orthogonal matrices the model equations result in non-constant parameters and ellipsoidal α-β current components, while the use of non-orthogonal matrices result in the same pre-fault components and consequently circular α-β currents [102]. 2.5.4.3 POST-FAULT CURRENT REFERENCE Post-fault performance and drive system safe operation depend directly on the proper selection of the current references that will be provided to the controller. If current references are maintained as in pre-fault operation, high torque ripples will be observed, leading to further machine damage [168, 170]. Optimum current reference calculation depends on the specific electrical drive configuration and machine winding connection. For instance, the current references imposed for the “single VSC” operation of a faulty six-phase drive remain symmetrical as in pre-fault operation [153]. However, this is not the case for five-phase two level induction machines, where healthy phase current references are calculated, considering the machines symmetry (healthy phase currents sum is equal to zero), ensuring a rotating air-gap MMF and the cancelation of torque ripple terms, during steady state operation [102]. Most of the proposed current reference calculation methods are implemented offline, using the machines model and the desired torque reference in order to estimate the desired waveforms. However, a method for online current reference estimation based on the desired torque was presented in [103]. Depending on the control criteria aim, two different approaches are found in the literature [102, 103]. 1. Maximum torque or minimum derating method (MT). MT is based on feeding the
Chapter 2 55 machine using balanced currents with equal shape and magnitude, providing a desired reference torque. The healthy phase currents are calculated for the maximum peak value allowed by the drive ratings (nominal RMS value) and with the optimum phase displacement in order to maintain constant torque with minimum ripple and equal copper losses distribution [104, 148, 151, 171, 172]. Even though copper losses are symmetrically distributed among healthy phases, temperature is not and depends on the type of fault and location [103]. 2. Minimum loss or minimum copper loss (ML). Contrary to MT, ML is based on feeding unbalanced currents to achieve the desired torque reference, while minimizing overall copper losses. Under minimum copper loss operation the magnitude of phase currents is not considered and consequently unequal RMS phase currents are observed [116, 159, 173]. As can be expected, post-fault performance will depend on the drive derating and the specific implemented control criteria. If phase currents are maintained within rated values, MT will result in higher torque production capability at the expense of higher losses compared to ML, where the asymmetrical current waveforms diminish the torque production. Moreover, if for instance phase currents are not maintained within rated values with ML criteria, the machine would be subject to possible magnetic saturation effects and unequal temperature distribution [102]. Based on these two general control aims, different current waveform references have been studied, exploiting the ability to control not only the fundamental frequency but also higher order current harmonics [102], further improving post-fault capabilities. Reference currents based on solely the fundamental component or sinusoidal reference currents [102] have been studied considering different machine models and optimization methods [115, 153, 170], for distributed winding induction machines where spatial harmonics can be neglected. In general terms, the α-β current references are calculated in order to provide a desired smooth rotating MMF, while the x-y current references are determined depending on the specific effect that the fault has on the electrical machine and on the adopted post-fault criteria (i.e. reduce copper losses or ensure maximum torque). Fault occurrence, location and nature affect the machines modeling equations and consequently different transformation matrices are used for the VSD, obtaining either circular or ellipsoidal currents [155, 168, 153, 169]. In case that higher order spatial harmonics are not negligible (i.e. affect torque production), x-y current components under either ML o MT control criteria generate
Multiphase Drives: Generalities, Modeling and Control 56 low-frequency torque ripple [102]. Nonetheless, this torque pulsation can be reduced by appropriately selecting x-y current references, at the expense of higher copper losses and reduced torque derating [155]. Sinusoidal current references have been also studied considering machines with pentagon and pentacle winding connections [45, 164, 165]. Even though similar performance is obtained with one open-circuit fault in star- and pentaconnections, the extra degree of freedom of penta-type connections, allow post-fault operation with up to three open-phase faults. On the other hand reference currents considering both fundamental and higher frequency components, leading to non-sinusoidal currents also termed as multi-frequency reference currents [102], have been proposed to manage post-fault performance of PM machines with trapezoidal Back- EMF or electrical drives with different number of faulty phases [44, 103, 116, 148, 157, 165]. Even though the control becomes much more difficult to implement, proposed research aims to exploit the effect of different current harmonics as an extra degree of freedom in order to improve and optimize post-fault operation. Online and off-line reference current calculation methods have been proposed in the literature [103, 116], based on scalar and vectorial methods [103] and obtaining similar performance. ML and MT criteria have been considered [103, 116, 148, 157], with either one or two open-phase faults. For instance, third order harmonics are considered in [148] to compensate torque pulsations, while reference currents have been optimized in [157, 159] to ensure maximum torque production with minimum ripple and to operate PM machines in the flux-weakening region. Pentagon and pentacle winding connections have also been analyzed in [44, 147, 165], considering phase/line and open/short circuit faults, further proving the improved fault-tolerance capabilities these types of machines possess when compared to traditional star-winding machines [102]. 2.5.4.4 POST-FAULT CONTROL TECHNIQUES Post-fault operation can be sustained either under open- or closedloop control. While open loop-control results in simpler implementation, the machine torque and currents are subject to significant ripple and unbalance, resulting in excessive vibration and losses [156]. On the other hand closed-loop control offers the capability to improve post-fault torque and current waveforms. The improvement is however obtained at the expense of an increment in the implementation complexity. Unbalanced machine voltages are also required and, depending on the post-fault control criteria, some DC-Link voltage reserve. Notice that the type of controller (i.e. linear, non-linear, predictive), depends on the implemented post-fault criteria, being necessary to meet the following constraints [102]:
Chapter 2 63 [20] R. Nelson, P. Krause, “Induction Machine Analysis for Arbitrary Displacement Between Multiple Winding Sets,” IEEE Transactions on Power Apparatus and Systems, vol. PAS–93, no. 3, pp. 841–848, 1974. [21] D. Hadiouche, H. Razik, A. Rezzoug, “On the Modeling and Design of Dual–Stator Windings to Minimize Circulating Harmonic Currents for VSI Fed AC Machines,” IEEE Transactions on Industry Applications, vol. 40, no. 2, pp. 506–515, 2004. [22] T. Lipo, “A d–q Model for Six Phase Induction Machines,” International Conference on Electric Machines, pp. 860-867, 1980. [23] R. Bojoi, M. Lazzari, F. Profumo, A. Tenconi, “Digital Field-Oriented Control for Dual Three-Phase Induction Motor Drives,” IEEE Transactions on Industry Applications, vol. 39, no. 3, pp. 752-760, 2003 [24] R. Bojoi, F. Profumo, A. Tenconi, “Digital Synchronous Frame Current Regulation for Dual Three- Phase Induction Motor Drives,” IEEE 34th Annual Power Electronics Specialists Conference. PESC03, vol. 3, no., pp.1475-1480 2003. [25] R. Bojoi, E. Levi, F. Farina, A. Tenconi; F. Profumo, “Dual Three-Phase Induction Motor Drive with Digital Current Control in the Stationary Reference Frame,” IEE Proceedings on Electric Power Applications, vol. 153, no. 1, pp. 129-139, 2006 [26] R. Bojoi, A. Tenconi, G. Griva, F. Profumo, “Vector Control of Dual-Three-Phase Induction-Motor Drives Using Two Current Sensors,” IEEE Transactions on Industry Applications, vol. 42, no. 5, pp. 1284- 1292, 2006 [27] R. Bojoi, F. Farina, G. Griva, F. Profumo, A. Tenconi, “Direct Torque Control for Dual Three–Phase Induction Motor Drives,” IEEE Transactions on Industry Applications, vol. 41, no. 6, pp. 1627-1636, 2005. [28] K. Hatua, V. Ranganathan, “Direct Torque Control Schemes for Split–Phase Induction Machine,” IEEE Transactions on Industry Applications, vol. 41, no. 5, pp. 1243-1254, 2005. [29] F. Barrero, M.R. Arahal, R. Gregor, S. Toral, M.J. Duran, “A Proof of Concept Study of Predictive Current Control for VSI Driven Asymmetrical Dual Three-phase AC Machines,” IEEE Transactions on Industrial Electronics, vol. 56, no. 6, pp. 1937-1954, 2009. [30] F. Barrero, J. Prieto, E. Levi, R. Gregor, S. Toral, M. Duran, M. Jones, “An Enhanced Predictive Current Control Method for Asymmetrical Six-phase Motor Drives,” IEEE Transactions on Industrial Electronics, vol. 58, no. 8, pp. 3242-3252, 2011. [31] Y. Zhao, T.A. Lipo, “Space Vector PWM Control of Dual Three-Phase Induction Machine Using Vector Space Decomposition,” IEEE Transactions on Industry Applications, vol. 31, no. 5, pp. 1100-1109, 1995. [32] F. Barrero, M.R. Arahal, R. Gregor, S. Toral, M.J. Durán, “One-step Modulation Predictive Current Control Method for the Asymmetrical Dual Three-Phase Induction Machine,” IEEE Transactions on Industrial Electronics, vol. 56, no. 6, pp. 1974-1983, 2009. [33] R. Gregor, F. Barrero, S. Toral, M.J. Duran, M.R. Arahal, J. Prieto, J.L. Mora, “Predictive-SVPWM Current Control Method for Asymmetrical Dual Three-Phase Induction Motor Drives,” IET Electric Power Applications, vol. 4, no. 1, pp. 26-34, 2010. [34] J. Prieto, M. Jones, F. Barrero, E. Levi, S. Toral, “Comparative Analysis of Discontinuous and Continuous PWM Techniques in VSI-Fed Five-Phase Induction Motor,” IEEE Transactions on Industrial Electronics, vol. 58, no. 12, pp. 5324-5335, 2011. [35] D. Dujic, M. Jones, E. Levi, J. Prieto, F. Barrero, “Switching Ripple Characteristics of Space Vector PWM Schemes for Five-Phase Two-Level Voltage Source Inverters—Part 1: Flux Harmonic Distortion Factors,” IEEE Transactions on Industrial Electronics, vol. 58, no. 7, pp. 2789-2798, 2011. [36] M. Jones, D. Dujic, E. Levi, J. Prieto, F. Barrero, “Switching Ripple Characteristics of Space Vector PWM Schemes for Five-Phase Two-Level Voltage Source Inverters—Part 2: Current Ripple,” IEEE Transactions on Industrial Electronics, vol. 58, no. 7, pp. 2799-2808, 2011. [37] M. Jones, S. Vukosavic, D. Dujic, E. Levi, “A Synchronous Current Control Scheme for Multiphase Induction Motor Drives,” IEEE Transactions on Energy Conversion, vol. 24, no. 4, pp. 860-868, 2009.
Multiphase Drives: Generalities, Modeling and Control 64 [38] L. Zheng, J. Fletcher, B. Williams, X. He, “Dual–Plane Vector Control of a Five–Phase Induction Machine for an Improved Flux Pattern,” IEEE Transactions on Industrial Electronics, vol. 55, no. 5, pp. 1996-2005, 2008. [39] G. Liliang, J. Fletcher, L. Zheng, “Low–Speed Control Improvements for a Two–Level Five–Phase Inverter–Fed Induction Machine Using Classic Direct Torque Control,” IEEE Transactions on Industrial Electronics, vol. 58, no. 7, pp. 2744-2754, 2011. [40] L. Zheng, J. Fletcher, B. Williams, X. He, “A Novel Direct Torque Control Scheme for a Sensorless Five–Phase Induction Motor Drive,” IEEE Transactions on Industrial Electronics, vol. 58, no. 2, pp. 503- 513, 2011. [41] C. Lim, E. Levi, M. Jones, N. Abd Rahim, W. Hew, “FCS-MPC-Based Current Control of a Five- Phase Induction Motor and its Comparison with PI-PWM Control,” IEEE Transactions on Industrial Electronics, vol. 61, no. 1, pp.149-163, 2014. [42] J. Riveros, F. Barrero, E. Levi, M.J. Durán, M. Jones, S. Toral, “Variable-Speed Five-Phase Induction Motor Drive Based on Predictive Torque Control,” IEEE Transactions on Industrial Electronics, vol. 60, no. 8, pp. 2957-2968, 2013. [43] S. Sadeghi, G. Lusu, H.A. Toliyat, L. Parsa, “Wide Operational Speed Range of Five-Phase Permanent Magnet Machines by Using Different Stator Winding Configurations,” IEEE Transactions on Industrial Electronics, vol. 59, no. 6, pp. 2621-2631, 2012. [44] A. Mohammadpour, L. Parsa, “A Unified Fault-Tolerant Current Control Approach for Five-Phase PM Motors with Trapezoidal Back EMF under Different Stator Winding Connections,” IEEE Transactions on Power Electronics, vol. 28, no. 7, pp. 3517-3527, 2013. [45] A.S. Abdel-Khalik, A.S. Morsy, S. Ahmed, A.M. Massoud, “Effect of Stator Winding Connection on Performance of Five-Phase Induction Machines,” IEEE Transactions on Industrial Electronics, vol. 61, no. 1, pp. 3-19, 2014. [46] E. Levi, M. Jones, S. Vukosavic, H. Toliyat, “A Novel Concept of Multiphase, Multimotor Vector Controlled Drive System Supplied from a Single Voltage Source Inverter,” IEEE Transactions on Power Electronics, vol. 19, no. 2, pp. 320-335, 2004. [47] E. Levi, M. Jones, S.N. Vukosavic, H.A. Toliyat, “Operating Principles of a Novel Multiphase Multimotor Vector-Controlled Drive,” IEEE Transactions on Energy Conversion, vol. 19, no. 3, pp. 508- 517, 2004 [48] E. Levi, M. Jones, S.N. Vukosavic, A. Iqbal, H.A. Toliyat, “Modeling, Control, and Experimental Investigation of a Five-Phase Series-Connected Two-Motor Drive With Single Inverter Supply,” IEEE Transactions on Industrial Electronics, vol. 54, no. 3, pp. 1504-1516, 2007 [49] E. Levi, S. Vukosavic, M. Jones, “Vector Control Schemes for Series–Connected Six–Phase Two– Motor Drive Systems,” IEE Proceedings Electric Power Applications, vol. 152, no. 2, pp. 226-238, 2005. [50] K. Mohapatra, R. Kanchan, M. Baiju, P. Tekwani, K. Gopakumar, “Independent Field–Oriented Control of two Split–Phase Induction Motors from a Single Six–Phase Inverter,” IEEE Transactions on Industrial Electronics, vol. 52, no. 5, pp. 1372-1382, 2005. [51] E. Levi, M. Jones, A. Iqbal, S.N. Vukosavic, H.A. Toliyat, “Induction Machine/Syn-Rel Two-Motor Five-Phase Series-Connected Drive,” IEEE Transactions on Energy Conversion, vol. 22, no. 2, pp. 281- 289, 2007 [52] E. Levi, M. Jones, S. Vukosavic, H. Toliyat, “Steady–state modeling of series–connected five–phase and six–phase two–motor drives,” IEEE Transactions on Industry Applications, vol. 44, no. 5, pp. 1559- 1568, 2008. [53] D. C. White, H. H.Woodson, “Electromechanical Energy Conversion,” Wiley, 1959. [54] P. C. Krause, O. Wasynczuk, S. D. Sudhoff, “Analysis of Electric Machinery and Drive Systems,” Wiley-Interscience, 2002. [55] A. M. Trzynadlowski, “Control of Induction Motors,” Elsevier, 2000. [56] M.J. Duran, J.A. Riveros, F. Barrero, H. Guzman, J. Prieto, “Reduction of Common-Mode Voltage in Five-Phase Induction Motor Drives Using Predictive Control Techniques,” IEEE Transactions on Industry Applications, vol. 48, no. 6, pp. 2059-2067, 2012.
Chapter 2 65 [57] N. Mohan, T. Underland, W. Robbins, “Power Electronics,” Wiley, 2003. [58] H. Chih-Yi, W. Chao-Peng, Y. Jung-Tai, H. Yeu-Jent, “Torque and Current Control of Induction Motor Drives for Inverter Switching Frequency Reduction,” IEEE Transactions on Industrial Electronics, vol. 52, no. 5, pp. 1364-1371, 2005. [59] B.K. Bose, “An Adaptive Hysteresis-Band Current Control Technique of a Voltage-Fed PWM Inverter for Machine Drive System,” IEEE Transactions on Industrial Electronics, vol. 37, no. 5, pp. 402-408, 1990 [60] G. Singh, K. Nam, S. Lim, “A Simple Indirect Field–Oriented Control Scheme for Multiphase Induction Machine,” IEEE Transactions on Industrial Electronics, vol. 52, no. 4, pp. 1177-1184, 2005. [61] K. Takahashi, K. Ohishi, T. Kanmachi, “A New Quick–Response and High–Efficiency Control Strategy of an Induction Motor,” IEEE Transactions on Industry Applications, vol. IA–22, no. 5, pp. 820– 827, 1986. [62] H. Toliyat, H. Xu, “A Novel Direct Torque Control (DTC) Method for Five–Phase Induction Machines,” Fifteenth Anual IEEE Applied Power Electronics Conference and Exposition, APEC, vol. 1, pp. 162-168, 2000. [63] N. Oikonomou, “Control of Medium-Voltage Drives at Very Low Switching Frequency,” PhD Thesis, Elektrotechnik, Informationstechnik und Medientechnik der Bergischen Universität Wuppertal, 2008. [64] J. Holtz, Q. Juntao, J. Pontt, J. Rodriguez, P. Newman, H. Miranda, “Design of Fast and Robust Current Regulators for High-Power Drives Based on Complex State Variables,” IEEE Transactions on Industry Applications, vol. 40, no. 5, pp. 1388-1397, 2004. [65] R. Hyung-Min, K. Jang-Hwan, S. Seung-Ki, “Analysis of Multiphase Space Vector Pulse-Width Modulation Based on Multiple d-q Spaces Concept,” IEEE Transactions on Power Electronics, vol. 20, no. 6, pp. 1364-1371, 2005. [66] J.W. Kelly, E.G. Strangas, J.M. Miller, “Multiphase Space Vector Pulse Width Modulation,” IEEE Transactions on Energy Conversion, vol. 18, no. 2, pp. 259-264, 2003. [67] A. Iqbal, E. Levi, “Space Vector PWM Techniques for Sinusoidal Output Voltage Generation With a Five–Phase Voltage Source Inverter,” Electric Power Components and Systems, vol. 34, no. 2, pp. 119- 140, 2006. [68] O. Lopez, D. Dujic, M. Jones, F.D. Freijedo, J. Doval-Gandoy, E. Levi, “Multidimensional Two-Level Multiphase Space Vector PWM Algorithm and its Comparison with Multifrequency Space Vector PWM Method,” IEEE Transactions on Industrial Electronics, vol. 58, no. 2, pp. 465-475, 2011 [69] A. Iqbal, E. Levi, M. Jones, S. Vukosavic, “Generalised Sinusoidal PWM with Harmonic Injection for Multi–Phase VSIs,” IEEE Power Electronics Specialists Conference, PESC37th, pp. 1-7, 2006. [70] D. Dujic, G. Grandi, M. Jones, E. Levi, “A Space Vector PWM Scheme for Multifrequency output Voltage Generation with Multiphase Voltage-Source Inverters,” IEEE Transactions on Industrial Electronics, vol. 55, no. 5, pp. 1943-1955, 2008. [71] G.S. Buja, M.P. Kazmierkowski, “Direct Torque Control of PWM Inverter-Fed AC Motors - A Survey,” IEEE Transactions on Industrial Electronics, vol. 51, no. 4, pp. 744-757, 2004. [72] R. Kianinezhad, R. Alcharea, B. Nahid, F. Betin, G. Capolino, “A Novel Direct Torque Control (DTC) for Six-Phase Induction Motors with Common Neutrals,” International Symposium on Power Electronics, Electrical Drives, Automation and Motion, 2008. SPEEDAM 2008, pp. 107-112, 2008. [73] R. Kianinezhad, B. Nahid, F. Betin, G.A. Capolino, “A Novel Direct Torque Control (DTC) Method For Dual Three Phase Induction Motors,” IEEE International Conference on Industrial Technology, 2006. ICIT 2006, pp. 939-943, 2006. [74] L. Zheng; J.E Fletcher, B.W. Williams, He Xiangning, “A Novel Direct Torque Control Scheme for a Sensorless Five-Phase Induction Motor Drive,” IEEE Transactions on Industrial Electronics, vol. 58, no. 2, pp. 503-513, 2011. [75] D. Casadei, F. Profumo, G. Serra, A. Tani, “FOC and DTC: Two Viable Schemes for Induction Motors Torque Control,” IEEE Transactions on Power Electronics, vol. 17, no. 5, pp. 779-787, 2002. [76] L. Parsa, “Performance Improvement of Permanent Magnet AC Motors,” PhD Thesis, Texas A&M University, 2005.
Multiphase Drives: Generalities, Modeling and Control 66 [77] Y. Gao, L. Parsa, “Modified Direct Torque Control of Five-Phase Permanent Magnet Synchronous Motor Drives,” Twenty Second Annual IEEE Applied Power Electronics Conference, APEC 2007, pp. 1428-1433, 2007. [78] S. Lu, K. Corzine, “Direct Torque Control of Five-Phase Induction Motor using Space Vector Modulation with Harmonics Elimination and Optimal Switching Sequence,” Twenty-First Annual IEEE Applied Power Electronics Conference and Exposition, 2006. APEC '06, 2006. [79] Y. Fei, Z. Xiaofeng, Q. Minzhong, D. Chengdong, “The direct torque control of multiphase permanent magnet synchronous motor based on low harmonic space vector PWM,” IEEE International Conference on Industrial Technology, 2008. ICIT 2008, pp. 1-5, 2008. [80] L. Parsa, H.A. Toliyat, “Sensorless Direct Torque Control of Five-Phase Interior Permanent-Magnet Motor Drives,” IEEE Transactions on Industry Applications, vol. 43, no. 4, pp. 952-959, 2007. [81] J. Riveros, M. Duran, F. Barrero, S. Toral, “Direct Torque Control for Five–Phase Induction Motor Drives with Reduced Common–Mode Voltage,” 38th Conference of the IEEE Industrial Electronics Society, IECON, pp. 3616-3621, 2012. [82] P. Cortes, M.P. Kazmierkowski, R.M. Kennel, D.E. Quevedo, J. Rodriguez, “Predictive Control in Power Electronics and Drives,” IEEE Transactions on Industrial Electronics, vol. 55, no. 12, pp. 4312- 4324, 2008. [83] S. Kouro, P. Cortes, R. Vargas, U. Ammann, J. Rodriguez, “Model Predictive Control—A Simple and Powerful Method to Control Power Converters,” IEEE Transactions on Industrial Electronics, vol. 56, no. 6, pp. 1826-1838, 2009. [84] J. Rodriguez, R.M. Kennel, J.R. Espinoza, M. Trincado, C.A. C.A. Silva, Rojas, “High-Performance Control Strategies for Electrical Drives: An Experimental Assessment,” IEEE Transactions on Industrial Electronics, vol. 59, no. 2, pp. 812-820, 2012. [85] L-H. Hoang, K. Slimani, P. Viarouge, “Analysis and Implementation of a Real-Time Predictive Current Controller for Permanent-Magnet Synchronous Servo Drives,” IEEE Transactions on Industrial Electronics, vol. 41, no. 1, pp. 110-117, 1994. [86] M. Hyung-Tae, K. Hyun-Soo, Y. Myung-Joong, “A Discrete-Time Predictive Current Control for PMSM,” IEEE Transactions on Power Electronics, vol. 18, no. 1, pp. 464-472, 2003. [87] L. Springob, J. Holtz, “High-Bandwidth Current Control for Torque-Ripple Compensation in PM Synchronous Machines,” IEEE Transactions on Industrial Electronics, vol. 45, no. 5, pp. 713-721, 1998. [88] R. S. Arashloo; J. L. Martinez Romeral, M. Salehifar, J. M. Moreno, “Model Predictive Current Control of Five Phase Permanent Magnet Motor,” European Conference on Power Electronics and Applications (EPE), 2013 15th, pp. 1-6, 2013. [89] M. Depenbrock, “Direct Self-Control (DSC) of Inverter-Fed Induction Machine,” IEEE Transactions on Power Electronics, vol. 3, no. 4, pp. 420-429, 1988. [90] A. Linder, R. Kennel, “Model Predictive Control for Electrical Drives,” IEEE 36th Power Electronics Specialists Conference, 2005. PESC '05, pp. 1793-1799, 2005. [91] R. Kennel, A. Linder, M. Linke, “Generalized Predictive Control (GPC)-Ready for use in Drive Applications?,” IEEE 32nd Annual Power Electronics Specialists Conference, 2001. PESC. 2001, pp. 1839-1844, 2001. [92] J. Rodriguez, M.P. Kazmierkowski, J.R. Espinoza, P. Zanchetta, H. Abu-Rub, H.A. Young, C.A. Rojas, “State of the Art of Finite Control Set Model Predictive Control in Power Electronics,” IEEE Transactions on Industrial Informatics, vol. 9, no. 2, pp. 1003-1016, 2013. [93] M.R. Arahal, F. Barrero, S. Toral, M.J. Durán, R. Gregor, “Multi-Phase Current Control Using Finite– state Model-Predictive Control,” Control Engineering Practice, vol. 17, no. 5, pp. 579-587, 2009. [94] J. Martinez, R. Kennel, T. Geyer, “Model Predictive Direct Current Control,” Proceedings IEEE ICIT, pp. 1808-1813, 2010. [95] T. Geyer, G. Papafotiou, M. Morari, “Model Predictive Direct Torque Control—Part I: Concept, Algorithm, and Analysis,” IEEE Transactions on Industrial Electronics, vol. 56, no. 6, pp. 1894-1905, 2009.
Chapter 2 67 [96] T. Geyer, “A Comparison of Control and Modulation Schemes for Medium Voltage Drives: Emerging Predictive Control Concepts Versus Field Oriented Control,” IEEE Energy Conversion Congress and Exposition (ECCE), 2010, pp. 2836–2843, 2010. [97] J. Holtz, “The Representation of AC Machine Dynamics by Complex Signal Flow Graphs,” IEEE Transactions on Industrial Electronics, vol. 42, no. 3, pp. 263-271, 1995. [98] H. Miranda, P. Cortes, J. Yuz, J. Rodriguez, “Predictive Torque Control of Induction Machines Based on State-Space Models,” IEEE Transactions on Industrial Electronics, vol. 56, no. 6, pp. 1916-1924, 2009. [99] J.A. Riveros, J. Prieto, F. Barrero, S. Toral, M. Jones, E. Levi, “Predictive Torque Control for Five- Phase Induction Motor Drives,” 36th Annual Conference on IEEE Industrial Electronics Society IECON 2010, pp. 2467-472, 2010. [100] M. J. Duran, J. Prieto, F. Barrero, S. Toral, “Predictive Current Control of Dual Three-Phase Drives using Restrained Search Techniques,” IEEE Transactions on Industrial Electronics, vol. 58, no. 8, pp. 3253-3263, 2011. [101] A. Consoli, “Special Section on Robust Operation of Electrical Drives,” IEEE Transactions on Power Electronics, vol. 27, no. 2, pp. 472-478, 2012. [102] F. Barrero, M. J. Duran, “Recent Advances in the Design, Modeling and Control of Multiphase Machines,” IEEE Transactions on Industrial Electronics, vol. -, no. -, pp. -, 2015. [103] X. Kestelyn, E. Semail, “A Vectorial Approach for Generation of Optimal Current References for Multiphase Permanent-Magnet Synchronous Machines in Real Time,” IEEE Transactions on Industrial Electronics, vol. 58, no. 11, pp. 5057-5065, 2011. [104] L. Parsa, H. A. Toliyat, “Fault-Tolerant Interior-Permanent-Magnet Machines for Hybrid Electric Vehicle Applications,” IEEE Transactions on Vehicular Technology, vol. 56, no. 4, pp. 1546-1552, 2007. [105] X. Huang, A. Goodman, C. Gerada, Y. Fang, Q. Lu, “Design of a Five-Phase Brushless DC Motor for a Safety Critical Aerospace Application,” IEEE Transactions on Industrial Electronics, vol. 59, no. 9, pp. 3532-3541, 2012. [106] H.S. Che, E. Levi, M. Jones, M.J. Duran, W.P. Hew, N.A. Rahim “Operation of a Six-Phase Induction Machine Using Series-Connected Machine-Side Converters,” IEEE Transactions on Industrial Electronics, vol. 61, no. 1, pp. 164-176, 2014. [107] A. Stefani, “Induction Motor Diagnosis in Variable Speed Drives,” PhD Thesis, Department of Electrical Engineering, University of Bologna, 2010. [108] Pinjia Zhang, Yi Du, T.G. Habetler, Bin Lu, “A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors,” IEEE Transactions on Industry Applications, vol. 47, no. 1, pp. 34-46, 2011. [109] A. H. Bonnett, C. Yung, “Increased Efficiency Versus Increased Reliability,” IEEE Industry Applications Magazine, vol. 14, no. 1, pp. 29-36, 2008. [110] S. Nandi, H. A. Toliyat, and X. Li, “Condition Monitoring and Fault Diagnosis of Electrical Motors - A Review,” IEEE Transactions on Energy Conversion, vol. 20, pp. 719-729, 2005. [111] A. M. da Silva, “Induction Motor Fault Diagnostic and Monitoring Methods” MSc Thesis, Marquette University, 2006. [112] P. Vas, “Parameter Estimation, Condition Monitoring, and Diagnosis of Electrical Machines,” Oxford, U.K.: Clarendon, 1993. [113] L. Zarri, M. Mengoni, Y. Gritli, A. Tani, F. Filippetti, G. Serra, D. Casadei, “Detection and Localization of Stator Resistance Dissymmetry Based on Multiple Reference Frame Controllers in Multiphase Induction Motor Drives,” IEEE Transactions on Industrial Electronics, vol. 60, no. 8, pp. 3506-3518, 2013. [114] M. Barcaro, N. Bianchi, F. Magnussen, “Faulty Operations of a PM Fractional-Slot Machine with a Dual Three-Phase Winding,” IEEE Transactions on Industrial Electronics, vol. 58, no. 9, pp. 3825-3832, 2011. [115] A.S. Abdel-Khalik, M.I. Masoud, S. Ahmed, A. Massoud, “Calculation of Derating Factors Based On Steady-State Unbalanced Multiphase Induction Machine Model Under Open Phase(s) And Optimal Winding Currents,” Elsevier Electric Power System Research, vol. 106, pp. 214-225, 2014.
Multiphase Drives: Generalities, Modeling and Control 68 [116] S. Dwari, L. Parsa, “An Optimal Control Technique for Multiphase PM Machines Under Open-Circuit Faults,” IEEE Transactions on Industrial Electronics, vol. 55, no. 5, pp. 1988-1995, 2008. [117] D. Foito, J. Maia, V.F. Pires, J.F. Martins, “Fault Diagnosis In Six-Phase Induction Motor Using A Current Trajectory Mass Center,” Elsevier Measurement, vol. 51, no. 1, pp. 164-173, 2014. [118] M. Salehifar, R.S. Arashloo, J.M. Moreno-Equilaz, V. Sala, L. Romeral, “Fault Detection and Fault Tolerant Operation of a Five Phase PM Motor Drive Using Adaptive Model Identification Approach,” IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. 2, no.2, pp. 212-223, 2014. [119] H. Henao, C. Demian, and G. A. Capolino, “A frequency-domain detection of stator winding faults in induction machines using an external flux sensor,” IEEE Transactions on Industry Applications, vol. 39, no. 5, pp. 1272–1279, 2003. [120] H. A. Toliyat, T. A. Lipo, “Transient analysis of cage induction machines under stator, rotor bar and end ring faults,” IEEE Transactions on Energy Conversion, vol. 10, no. 2, pp. 241–247, 1995. [121] M. E. H. Benbouzid, “A Review of Induction Motors Signature Analysis as a Medium for Faults Detection,” IEEE Transactions on Industrial Electronics, vol. 47, no. 5, pp. 984-993, 2000. [122] B. Akin, Choi Seungdeog, U. Orguner, H.A. Toliyat, “A Simple Real-Time Fault Signature Monitoring Tool for Motor-Drive-Embedded Fault Diagnosis Systems,” IEEE Transactions on Electronics, vol. 58, no. 5, pp. 1990-2001, 2011. [123] G.F.H. Beng, X. Zhang, D.M. Vilathgamuwa, “Sensor Fault-Resilient Control of Interior Permanent- Magnet Synchronous Motor Drives,” IEEE/ASME Transactions on Mechatronics, vol. 20, no. 2, pp. 855- 864, 2015. [124] S.M. Bennett, R.J. Patton, S. Daley, “Rapid Prototyping of a Sensor Fault Tolerant Traction Control System,” IEE Colloquium on Fault Diagnosis in Process Systems (Digest No: 1997/174), 1997. [125] Hainan Wang, S. Pekarek, B. Fahimi, “Multilayer Control of an Induction Motor Drive:A Strategic Step for Automotive Applications,” IEEE Transactions on Power Electronics, vol. 21, no. 3, pp. 676-686, 2006. [126] D. Chakraborty, V. Verma, “Speed and Current Sensor Fault Detection and Isolation Technique for Induction Motor Drive Using Axes Transformation,” IEEE Transactions on Industrial Electronics, vol. 62, no. 3, pp. 1943-1954, 2015. [127] C. Hung-Chi, H. Chih-Hao, C. Da-Kai, “Position Sensorless Control for Five-Phase Permanent- Magnet Synchronous Motors,” IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM2014), 2014. [128] A.S. Morsy, A.S. Abdel-khalik, S. Ahmed, A.M. Massoud, “Sensorless Speed Control of a Five-Phase Induction Machine Under Open-Phase Condition”, The Journal of Engineering, IET Open Access, 2014. [129] T. A. Najafabadi, F. R. Salmasi, P. J. Maralani, “Detection and Isolation of Speed-, DC-Link Voltage- , and Current-Sensor Faults Based on an Adaptive Observer in Induction-Motor Drives,” IEEE Transactions on Industrial Electronics, vol. 58, no. 5, pp. 1662-1672, 2011. [130] F. Zidani, M. E. H. Benbouzid, D. Diallo, A. Benchaib, “Active Fault-Tolerant Control of Induction Motor Drives in EV and HEV Against Sensor Failures Using a Fuzzy Decision System,” IEEE International Conference on Electric Machines and Drives, IEMDC'03., vol. 2, pp. 677-683 vol. 2, 2003. [131] D. Diallo, M. E. H. Benbouzid, A. Makouf, “A Fault-Tolerant Control Architecture for Induction Motor Drives in Automotive Applications,” IEEE Transactions on Vehicular Technology, vol. 53, no. 6, pp. 1847-1855, 2004. [132] M. E. H. Benbouzid, D. Diallo, M. Zeraoulia, “Advanced Fault-Tolerant Control of Induction-Motor Drives for EV/HEV Traction Application: from Conventional to Modern and Intelligent Control Techniques,” IEEE Transactions on Vehicular Technology, vol. 56, no. 2, pp. 519-528, 2007. [133] B. Tabbache, N. Rizoug, M. E. H. Benbouzid, A. Kheloui, “A Control Reconfiguration Strategy for Post-Sensor FTC in Induction Motor Based EVs,” IEEE Transactions on Vehicular Technology, vol. 62, no. 3, pp. 965-971, 2013. [134] A. Raisemche, M. Boukhnifer, C. Larouci, D. Diallo, “Two Active Fault Tolerant Control Schemes of Induction Motor Drive in EV or HEV,” IEEE Transactions on Vehicular Technology, vol. 63, no. 1, pp. 19-29, 2014.
Chapter 2 69 [135] X. Shi, M. Krishnamurthy, “Survivable Operation of Induction Machine Drives With Smooth Transition Strategy for EV Applications,” IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. 2, no. 3, pp. 609-617, 2014. [136] Y.-S. Jeong, S.-K. Sul, S. E. Schulz, N. R. Patel, “Fault Detection and Fault-Tolerant Control of Interior Permanent-Magnet Motor Drive System for Electric Vehicle,” IEEE Transactions on Industrial Applications, vol. 41, no. 1, pp. 46-51, 2005. [137] K.-S. Lee, J.-S. Ryu, “Instrument Fault Detection and Compensation Scheme for Direct Torque Controlled Induction Motor Drives,” IEE Proceedings Control Theory and Applications, vol. 150, no. 4, pp. 376-382, 2003. [138] M. E. Romero, M. M. Seron, J. A. D. Dona, “Sensor Fault-Tolerant Vector Control of Induction Motors,” IET Control Theory & Applications, vol. 4, no. 9, pp. 1707-1724, 2010. [139] F. R. Salmasi, T. A. Najafabadi, “An Adaptive Observer with Online Rotor and Stator Resistance Estimation for Induction Motors With One Phase Current Sensor,” IEEE Transactions on Energy Conversion, vol. 26, no. 3, pp. 959-966, 2011. [140] X. Zhang, G. Foo, M. D. Vilathgamuwa, K. J. Tseng, B. S. Bhangu, C. Gajanayake, “Sensor Fault Detection, Isolation and System Reconfiguration Based on Extended Kalman Filter for Induction Motor Drives,” IET Electric Power Applications, vol. 7, no. 7, pp. 607-617, 2013. [141] A. B. Youssef, S. K. E. Khil, I. S. Belkhodja, “State Observer-Based Sensor Fault Detection and Isolation, and Fault Tolerant Control of a Single-Phase PWM Rectifier for Electric Railway Traction,” IEEE Transactions on Power Electronics, vol. 28, no. 12, pp. 5842-5853, 2013. [142] B. Tabbache, M. E. H. Benbouzid, A. Kheloui, J. M. Bourgeot, “Virtual-Sensor-Based Maximum- Likelihood Voting Approach for Fault-Tolerant Control of Electric Vehicle Powertrains,” IEEE Transactions on Vehicular Technology, vol. 62, no. 3, pp. 1075-1083, 2013. [143] J. Holtz, “Sensorless Control of Induction Machines-With or Without Signal Injection,” IEEE Transactions on Industrial Electronics, vol. 53, no. 1, pp. 7-30, 2006. [144] Z. Q. Zhu, L. M. Gong, “Investigation of Effectiveness of Sensorless Operation in Carrier-Signal- Injection-Based Sensorless-Control Methods,” IEEE Transactions on Industrial Electronics, vol. 58, no. 8, pp. 3431-3439, 2011. [145] W. Cao, B. Mecrow, G. Atkinson, J. Bennett, D. Atkinson, “Overview of Electric Motor Technologies Used for More Electric Aircraft (MEA),” IEEE Transactions on Industrial Electronics, vol. 59, no. 9, pp. 3523-3531, 2012. [146] F. Meinguet, N. Ngac-Ky, P. Sandulescu, X. Kestelyn, E. Semail, “Fault-Tolerant Operation of an Open-end Winding Five-Phase PMSM Drive With Inverter Faults,” in proc. of the 39th Annual Conference of the IEEE Industrial Electronics Society (IECON 2013), 2013. [147] A. Mohammadpour, L. Parsa, “Global Fault-Tolerant Control Technique for Multi-Phase Permanent- Magnet Machines,” IEEE Transactions on Industry Applications, vol. 51, no. 1, pp. 178-186, 2015. [148] N. Bianchi, S. Bolognani, M.D. Pré, “Strategies for the Fault-Tolerant Current Control of a Five-Phase Permanent-Magnet Motor,” IEEE Transactions on Industry Applications, vol. 43, no. 4, pp. 960-970, 2007. [149] M.O.E. Aboelhassan, T. Raminosoa, A. Goodman, L. de Lillo, C. Gerada, “Performance Evaluation of a Vector-Control Fault-Tolerant Flux-Switching Motor Drive,” IEEE Transactions on Industrial Electronics, vol. 60, no. 8, pp. 2997-3006, 2013. [150] L. Alberti, N. Bianchi, “Experimental Tests of Dual Three-Phase Induction Motor Under Faulty Operating Condition,” IEEE Transactions on Industrial Electronics, vol. 59, no. 5, pp. 2041-2048, 2012. [151] J. R. Fu, T.A. Lipo, “Disturbance Free Operation of a Multiphase Current Regulated Motor Drive with an Opened Phase,” IEEE Transactions on Industry Applications, vol. 30, no. 5, pp. 1267-1274, 1994. [152] Y. Zhao, T.A. Lipo, “Modeling and Control of a Multi-Phase Induction Machine with Structural Unbalance Part II. Field-Oriented Control and Experimental Verification,” IEEE Transactions on Energy Conversion, vol. 11, no. 3, pp. 578-584, 1996. [153] H.S. Che, M.J. Duran, E. Levi, M. Jones, W.P. Hew, N.A. Rahim, “Postfault Operation of an Asymmetrical Six-Phase Induction Machine with Single and Two Isolated Neutral Points,” IEEE Transactions on Power Electronics, vol. 29, no. 10, pp. 5406-5416, 2014.
Multiphase Drives: Generalities, Modeling and Control 70 [154] H.M. Ryu, J.W. Kim, S.K. Sul, “Synchronous-Frame Current Control of Multiphase Synchronous Motor Under Asymmetric Fault Condition Due to Open Phases,” IEEE Transactions on Industry Applications, vol. 42, no. 4, pp. 1062-1070, 2006. [155] A. Tani, M. Mengoni, L. Zarri, G. Serra, D. Casadei, “Control of Multi-Phase Induction Motors with an Odd Number of Phases Under Open-Circuit Phase Faults,” IEEE Transactions on Power Electronics, vol. 27, no. 2, pp. 565-577, 2012. [156] F. Locment, E. Semail, X. Kestelyn, “Vectorial Approach-Based Control of a Seven-Phase Axial Flux Machine Designed for Fault Operation,” IEEE Transactions on Industrial Electronics, vol. 55, no. 10, pp. 3682-3691, 2008. [157] S. Dwari, L. Parsa, “Fault-Tolerant Control of Five-Phase Permanent-Magnet Motors with Trapezoidal Back EMF,” IEEE Transactions on Industrial Electronics, vol. 58, no. 2, pp. 476-485, 2011. [158] A. Abdel-Khalik, A. Morsy , S. Ahmed, A. Massoud, “Effect of Stator Winding Connection on Performance of Five-phase Induction Machines,” IEEE Transactions on Industrial Electronics, vol. 61, no. 1, pp. 3-19, 2014. [159] Z. Sun, J. Wang, G.W. Jewell, D. Howe, “Enhanced Optimal Torque Control of Fault-Tolerant PM Machine Under Flux-Weakening Operation,” IEEE Transactions on Industrial Electronics, vol. 57, no. 1, pp. 344-353, 2010. [160] M.J. Durán, J. Prieto, F. Barrero, “Space Vector PWM With Reduced Common-Mode Voltage for Five-Phase Induction Motor Drives Operating in Overmodulation Zone,” IEEE Transactions on Power Electronics, vol. 28, no. 8, pp. 4030-4040, 2013. [161] G. Carrasco, C. Silva, “Space Vector PWM Method for Five-Phase Two-Level VSI with Minimum Harmonic Injection in the Over Modulation Region,” IEEE Transactions on Industrial Electronics, vol. 60, no. 5, pp. 2042-2053, 2013. [162] J. M. Apsley, “Derating of Multiphase Induction Machines due to Supply Imbalance,” IEEE Transactions on Industrial Applications, vol. 46, no. 2, pp. 798–805, 2010. [163] L. Zheng, J. E. Fletchert, B. W.Williams, “Current Optimization for a Multi-Phase Machine Under an Open Circuit Phase Fault Condition,” in Proceedings of 3rd IET International Conference on Power Electronics, Machines and Drives, 2006. [164] A.S. Abdel-Khalik, S Ahmed, A.A. Elserougi, A.M. Massoud, “Effect of Stator Winding Connection of Five-Phase Induction Machines on Torque Ripples Under Open Line Condition,” IEEE/ASME Transactions on Mechatronics, vol. 20, no. 2, pp. 580-593, 2015. [165] A. Mohammadpour, S. Sadeghi, L. Parsa, “A Generalized Fault-Tolerant Control Strategy for Five- Phase PM Motor Drives Considering Star, Pentagon, and Pentacle Connections of Stator Windings,” IEEE Transactions on Industrial Electronics, vol. 61, no. 1, pp. 63-75, 2014. [166] J.W. Bennett, B.C. Mecrow, D.J. Atkinson, G.J. Atkinson, “Safety-Critical Design of Electromechanical Actuation Systems in Commercial Aircraft,” IET Electric Power Applications, vol. 5, no. 1, pp. 37-47, 2011. [167] J.W. Bennett, G.J. Atkinson, B.C. Mecrow, D.J. Atkinson, “Fault-Tolerant Design Considerations and Control Strategies for Aerospace Drives,” IEEE Transactions on Industrial Electronics, vol. 59, no. 5, pp. 2049-2058, 2012. [168] R. Kianinezhad, B. Nahid-Mobarakeh, L. Baghli, F. Betin, GA. Capolino, “Modeling and Control of Six-Phase Symmetrical Induction Machine Under Fault Condition Due to Open Phase,” IEEE Transactions on Industrial Electronics, vol. 55, no. 5, pp. 1966-1977, 2008. [169] M.A. Fnaiech, F. Betin, G.A. Capolino, F. Fnaiech, “Fuzzy Logic and Sliding-Mode Controls Applied to Six-Phase Induction Machine With Open Phases,” IEEE Transactions on Industrial Electronics, vol. 57, no. 1, pp. 354-364, 2010. [170] F. Baudart, B. Dehez, E. Matagne, D. Teleu-Nedelcu, P. Alexandre, F. Labrique, “Torque Control Strategy of Polyphase Permanent-Magnet Synchronous Machines with Minimal Controller Reconfiguration Under Open-Circuit Fault of One Phase,” IEEE Transactions on Industrial Electronics, vol. 59, no. 6, pp. 2632-2644, 2012.
Chapter 2 71 [171] H. A. Toliyat, “Analysis and Simulation of Five-Phase Variable-Speed Induction Motor Drives Under Asymmetrical Connections,” IEEE Transactions on Power Electronics, vol. 13, no. 4, pp. 748-756, 1998. [172] J. Figueroa, J. Cros, P. Viarouge, “Polyphase PM Brushless DC Motor for High Reliability Application,” in Proceedings of the 10th European Conference on Power Electronics and Applications, (EPE 2003), 2003. [173] J. Wang, K. Atallah, D. Howe, “Optimal Torque Control of Fault-Tolerant Permanent Magnet Brushless Machines,” IEEE Transactions on Magnetics, vol. 39, no. 5, pp. 2962-2964, 2003. [174] A. Mohammadpour, S. Mishra, L. Parsa, “Fault-Tolerant Operation of Multiphase Permanent-Magnet Machines Using Iterative Learning Control,” IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. 2, no. 2, pp. 201-211, 2014. [175] F. Betin, G.A. Capolino, “Shaft Positioning for Six-Phase Induction Machines with Open Phases Using Variable Structure Control,” IEEE Transactions on Industrial Electronics, vol. 59, no. 6, pp. 2612-2620, 2012. [176] M.A. Shamsi-Nejad, B. Nahid-Mobarakeh, S. Pierfederici, F. Meibody-Tabar, “Fault Tolerant and Minimum Loss Control of Double Star Synchronous Machines Under Open Phase Conditions,” IEEE Transactions on Industrial Electronics, vol. 55, no. 5, pp. 1956-1965, 2008.
72 CHAPTER: 3 CONTRIBUTIONS 3.1 INTRODUCTION This Doctoral thesis work is focused on the extension of finite-control set model-based predictive control, for multiphase drives, to the fault-tolerant operation while ensuring efficient and controlled post-fault operation. In order to obtain an accurate system model, suitable for a FCS-MPC strategy, research work has been conducted in the mathematical study of the electrical machine equations under pre- and post-fault conditions considering different types of faults, providing further insight of the effect fault conditions have on the system behavior. Simulation models of a five-phase induction machine under two different types of faults namely, open-phase (produced by either an open-circuit line or phase fault) and IGBT-gating failure faults, where developed in order to design and test the FCS-MPC controller and their results were presented in several international conferences. Obtained results paved the way for the implementation and experimental validation of the proposed fault-tolerant strategy based on predictive control techniques on the laboratory test-rig, leading to two of the article contributions presented later on in this chapter. Subsequently, a fault-tolerant scheme based on linear controllers was designed based on research available in the state of the art literature and a comparison between the proposed predictive technique and a proportional resonant faulttolerant controller was conducted through simulation and experimental tests under an open-phase fault, leading to both an international conference and a journal paper publication. The contributions of this Thesis are presented in three different journal papers published in the IEEE Transactions on Industrial Electronics, between the years 2013/2015. Next, a summary of each journal paper is presented, highlighting their most important aspects. Subsequently, each journal paper is included.
Chapter 3 79 3.4 PERFORMANCE ANALYSIS OF FAULT-TOLERANT FCS-MPC AND LINEAR CONTROL TECHNIQUES Finally, the third journal paper entitled, “Comparative Study of Predictive and Resonant Controllers in Fault-Tolerant Five-phase Induction Motor Drives”, analyzes the performance of two open-phase fault-tolerant control schemes, based on linear and predictive control techniques, for fivephase induction machines, through a set of experimental tests (i.e. steady state, reversal and pre- to post-fault transition). Furthermore, provided tests are conducted at maximum post-fault ratings with either minimum copper loss (TL=0.56*Tn) or minimum derating criteria (TL=0.64*Tn), and consider steady state operation and control transition from pre- to post-fault, with and without fault detection delay of 40 ms. Even though both controllers are capable of post-fault operation, maintaining a sinusoidal MMF while achieving minimum losses, maximum torque per-ampere and reducing torque vibrations, its implementation is completely different due to the machine asymmetric effect on the control strategy. For instance, when a FCS-MPC control strategy is implemented (Fig. 3.1), the electrical model of the machine must be revised in order to account for the faulty phase and provide accurate predictions. Consequently, a modified Clarke transformation is considered in order to compensate the faulty machine asymmetries’ in the α-β subspace and the faulty phase counter electromotive force must be considered for the voltage vector estimation. On the other hand if a linear control strategy is implemented (Fig. 3.4), the electrical machine model and vector space decomposition remains as in pre-fault, due to the fact that the asymmetry in the impedance terms on the α-β plane does not have any effect on the controller performance and that there is no need to consider the faulty phase backemf in the voltage equilibrium equations. Nonetheless, the type of controller is changed from traditional PI to PR controllers, in order to handle the oscillating post-fault x-y current references. In order to compare the controller’s performance under the same conditions, both control schemes are based, as schematically shown in Fig. 3.1 and Fig. 3.4, either on pre- or post-fault operation, on an outer speed and flux control loop implemented in a rotor-flux-oriented d-q reference frame with conventional PI controllers. The d-current reference is set to a constant value and the q-current reference is determined by a PI controller based on the speed error. Under pre-fault operation, x-y current references are zero, thus PI controllers are used to follow the current references in the linear
Contributions 80 inner control scheme, while the traditional Clarke transformation, voltage matrix and the cost function considering both x and y current error are considered for the inner current predictive controller scheme. When the open-phase fault occurs, each inner control scheme is modified in order to achieve post-fault operation. Test results allow concluding that speed control in post-fault operation with inner faulttolerant schemes implemented based either on FCS-MPC (Fig. 3.1) or PR (Fig. 3.4) controllers is viable with similar performance. Moreover, both control methods ensure proper post-fault current reference tracking, either with the minimum copper loss or the minimum derating criteria at maximum post-fault ratings, maintaining the electrical drive within its maximum post-fault current limits. As expected from predictive methods, the speed response is faster than with the PR controller, but at the expense of higher torque and current ripple. However they are more affected in the transition from pre- to post-fault modes of operation due to the high dependence on the model accuracy, which is highly deviated during the fault detection delay. Regarding the implementation of each control scheme, it must be noted that the number of changes required to adapt the control structure to the faulty situation is higher when FCS-MPC are used when compared to PR control because of the necessity to consider the neutral point voltage oscillation and modify the Clarke transformation matrix. Nonetheless, it must be stated that in order to ensure a proper post-fault drive operation, the different PI constants must be correctly tuned, increasing the complexity during its implementation and limiting the behavior of the electrical drive only for the operating point for which the regulators have been tuned.
Chapter 3 81 Fig. 3.4.: Pre- and postfault drive topology and implemented control scheme based on an outer speed and flux loop and an inner open-phase fault-tolerant PR controller.
Contributions 82 3.5 JOURNAL PAPERS This section contains the following journal papers: Journal paper 1: Title: Speed Control of Five-Phase Induction Motors with Integrated Open-Phase Fault Operation using Model-Based Predictive Current Control Techniques. Authors: H. Guzman, M. J. Duran, F. Barrero, B. Bogado, S. Toral. Publication: IEEE Transactions on Industrial Electronics. DOI: 10.1109/TIE.2013.2289882. Journal paper 2: Title: IGBT-Gating Failure Effect on a Fault-Tolerant Predictive Current Controlled 5-Phase Induction Motor Drive. Authors: H. Guzman, F. Barrero, M. J. Duran. Publication: IEEE Transactions on Industrial Electronics. DOI: 10.1109/TIE.2014.2331019. Journal paper 3: Title: Comparative Study of Predictive and Resonant Controllers in Fault-Tolerant Five-phase Induction Motor Drives. Authors: H. Guzman, M. J. Duran, F. Barrero, L. Zarri, B. Bogado, I. Gonzalez Prieto, M. R. Arahal. Publication: IEEE Transactions on Industrial Electronics. DOI: 10.1109/TIE.2015.2418732.
Chapter 3 83 JOURNAL PAPER 1 Title: Speed Control of Five-Phase Induction Motors with Integrated Open-Phase Fault Operation using Model-Based Predictive Current Control Techniques. Authors: H. Guzman, M. J. Duran, F. Barrero, B. Bogado, S. Toral. Publication: IEEE Transactions on Industrial Electronics. Volume: 61 Issue: 9 Pages: 4474 - 4484 Year: 2014 DOI: 10.1109/TIE.2013.2289882. Summary: Fault-tolerance is one of the most interesting features in standalone electric propulsion systems. Multiphase induction motor drives are presented like a better alternative to their three-phase counterparts because of their capability to withstand faulty situations, ensuring the post-fault operation of the drive. Finite-control set model-based predictive control (FCSMPC) has been introduced in the last decade like an interesting alternative to conventional controllers for the electrical torque and current regulation of multiphase drives. However, FCS-MPC strategies for multiphase drives with the ability to manage pre- and post-fault operations have not been addressed at all. This paper proposes a fault tolerant speed control for five-phase induction motor drives with the ability to run the system before and after an open-phase fault condition using a FCS-MPC strategy. Experimental results are provided in order to validate the functionality of the proposed control method, maintaining rated currents and ensuring fast and ripple-free torque response.
Contributions 84 JOURNAL PAPER 2 Title: IGBT-Gating Failure Effect on a Fault-Tolerant Predictive Current Controlled 5-Phase Induction Motor Drive. Authors: H. Guzman, F. Barrero, M. J. Duran. Publication: IEEE Transactions on Industrial Electronics. Volume: 62 Issue: 1 Pages: 15 - 20 Year: 2015 DOI: 10.1109/TIE.2014.2331019. Summary: Multiphase machine drives are gaining importance in high reliability applications due to their fault-tolerance capability and their ability to cope with the post-fault operation without any extra electronic components. Predictive current controllers have been recently proposed for managing post-fault operation of these drives when an open phase fault is considered. However, the faulty situation assumes zero stator current while free-wheeling diodes can continue conducting in a non-controlled mode. This work analyses the post-fault operation of the five-phase drive when the free-wheeling diodes of the faulty phase are still conducting. Experimental results are provided using a conventional IGBT-based multiphase power converter to quantify the effect of the free-wheeling diodes, when an IGBT-gating fault occurs, on the model-based predictive current controlled drive.
Chapter 3 85 JOURNAL PAPER 3 Title: Comparative Study of Predictive and Resonant Controllers in Fault-Tolerant Five-phase Induction Motor Drives. Authors: H. Guzman, M. J. Duran, F. Barrero, L. Zarri, B. Bogado, I. Gonzalez Prieto, M. R. Arahal. Publication: IEEE Transactions on Industrial Electronics. Volume: PP Issue: 99 Pages: 1 - 1 Year: 2015 DOI: 10.1109/TIE.2015.2418732. Summary: One of the most attractive features of multiphase machines is the fault-tolerant capability due to the higher number of phases. Different post-fault control strategies based on hysteresis, PI- resonant and predictive techniques have been recently proposed. They all proved their capabilities to withstand fault situations and to preserve the fundamental component of the airgap field, while achieving minimum losses, maximum torque per-ampere and reducing torque vibrations. Nonetheless, due to their recent introduction, no thorough study has yet appeared comparing the performance of these controllers. In this paper two open-phase fault-tolerant control schemes are experimentally compared in a real five-phase induction machine. The controllers being compared are based on PI-resonant and predictive control techniques, respectively. The experiments include pre- and post-fault situations. Obtained results show that both control methods offer nearly the same performance. When compared, predictive control provides faster control response and superior performance at low speed operation but is found to be less resilient to fault detection delays and to have higher current ripple. Regarding the controller implementation, it is shown that the transition from pre- to postfault operation involves modelling the non-linear effects observed when an open-phase fault occurs for the predictive controller, and the proper retuning of the PI trackers for the PI-resonant controller, in order to ensure post-fault operation.
Chapter 3 113 3.6 SUMMARY In this chapter, the contributions that constitute this Doctoral thesis have been presented. Conducted research on the fault-tolerance capability of multiphase drives consisting on the mathematical study of the electrical machine equations under pre- and postfault conditions under different types of faults and the development/comparison of control strategies that are capable of ensuring post-fault operation, have resulted in the publication of three journal papers in the IEEE Transactions on Industrial Electronics, between the years 2013 and 2015, consisting on the proposal of a novel fault-tolerant technique for open-phase faults based on a FCS-MPC current control, the study of the proposed controller under an IGBT-Gating failure on both semiconductors of a converters phase and finally the comparison of the fault-tolerant FCS-MPC with proportional-resonant controllers. It is proved not only that controlled post-fault operation without extra hardware is feasible with multiphase drives, but also that predictive control techniques such as FCS-MPC can be extended to such type of operation obtaining similar performance as with traditional linear controllers.
115 CHAPTER: 4 CONCLUSIONS AND FUTURE WORK 4.1 CONCLUSIONS The main conclusions drawn from this Doctoral Thesis work can be summarized as: 1. Controlled post-fault operation of multiphase drives is feasible without extra hardware. 2. During an open-phase fault, the machine modeling equations must be revised in order to account for the loss of the faulty phase. In the first place, one control degree of freedom is lost and it is necessary to implement a modified Clarke transformation in order to provide symmetrical impedances and Back-EMF terms in the 𝛼-𝛽 subspace. Secondly, the faulty phase current is zero while its voltage is given by its Back-EMF term, which must be considered in the leg-to-phase voltage matrix, providing a different stator phase voltage matrix than in pre-fault operation. 3. Depending on the specific application constraints and type of multiphase drive, different post-fault control criteria can be successfully applied, aiming to reduce copper losses or to provide maximum torque. 4. Finite-Control Set Model-Based Predictive Control can be successfully extended to withstand post-fault operation. Moreover, the fast reference tracking of controlled variables inherent of predictive controllers makes the controller reconfiguration from pre- to post-fault operation one of the main advantages of this type of controllers when compared to fault-tolerant schemes based on linear controllers. 5. Due to the inherent necessity of FCS-MPC to account for an accurate system model, fault detection delay represents the main drawback of this technique for industrial applications, where obtained results show that during this period of time the faulttolerant FCS-MPC controller loses complete control capability.
Capítulo 5 122 de ascensores de velocidad ultra rápida empleando una máquina de imanes permanentes de nueve fases controlada por tres convertidores trifásicos [6]. Otros ejemplos de aplicaciones de alta potencia, fiabilidad y capaces de cumplir con estándares industriales, viables y basados en accionamientos multifásicos aparecen en el ámbito de la propulsión naval [7, 8] y en la refrigeración de una instalación de gas natural licuado (LNG por sus siglas en inglés). En el primer caso, como ejemplos de aplicaciones de máquinas multifásicas, un motor de inducción de 20 MW con quince fases y con tres neutros independientes, controlado por tres convertidores de cinco fases de la empresa Alstom es incorporado a un prototipo desarrollado por la marina de Estados Unidos [7]. Mientras que en el segundo caso, se diseña y se emplea para el sistema de refrigeración de una instalación de LNG, un motor de doce fases, 45 MW, 7200 voltios con cuatro neutros independientes, controlado por cuatro convertidores de tipo cascada multinivel trifásicos con IGBT’s [8]. Algunas de las ventajas de los accionamientos multifásicos, al ser comparados con accionamientos trifásicos convencionales, son [1, 9, 10, 11]: 1. Mejor distribución espacial de la fuerza magnetomotriz (MMF por sus siglas en inglés) en el entrehierro de la máquina [9], reduciendo las pérdidas en el cobre en el rotor. 2. Menor contenido de armónicos en las corrientes del estator. 3. Menores pulsaciones de par. Las máquinas multifásicas son menos susceptibles a las pulsaciones de par a baja frecuencia, causadas por los armónicos de orden (2𝑛±1) en una máquina de 𝑛-fases. 4. Menor contenido de armónicos en la corriente del DC-Link. 5. Mejor distribución de potencia por fase. Para una potencia nominal dada, la corriente nominal por cada fase disminuye conforme aumentan el número de fases. 6. Mayor número de grados de libertad en el control permitiendo: a. Accionamientos con alta capacidad de par. En máquinas multifásicas con devanados concentrados, es posible utilizar los componentes armónicos de bajo orden de las corrientes (tercer armónico en una máquina de cinco fases, tercero y quinto en una máquina de siete fases) para incrementar la capacidad de producción de par [12, 13]. b. Accionamientos con múltiples motores. Al conectar en serie los devanados del estator de un grupo de máquinas multifásicas con devanados distribuidos, es
Resumen en Español de la Tesis Doctoral 123 posible controlar independientemente con sólo un convertidor de potencia, diferentes números de máquinas [14, 15]. c. Accionamientos tolerantes a fallos. Más fiables que las máquinas trifásicas. En el caso de un fallo en una máquina trifásica, la máquina puede continuar funcionando como una máquina monofásica pero necesita equipo externo para arrancar y para controlar las oscilaciones de par. Por otra parte, una máquina de 𝑛-fases con una o más de sus fases en condición de fallo (dependiendo del número total de fases n y sus características constructivas), puede continuar generando un campo rotatorio sin requerir equipo externo siempre y cuando el número de fases abiertas no sea mayor a (𝑛−3), a cambio de una menor capacidad de par y de corriente. Las máquinas multifásicas se clasifican tradicionalmente dependiendo de la distribución de sus devanados como concentrados o distribuidos, o en función de la disposición de sus devanados como simétricas o asimétricas. Los accionamientos electromecánicos de tipo multifásico de devanados concentrados generan un flujo de campo con un alto contenido armónico cuando se les aplica una tensión de estator sinusoidal, el cual puede ser utilizado para aumentar la capacidad de producción de par eléctrico, frente a una distribución casi sinusoidal de la fuerza magnetomotriz conseguida con el bobinado distribuido donde los armónicos en el flujo sólo generan pérdidas electromagnéticas. Por otra parte, las máquinas simétricas están formadas por devanados desplazados 2𝜋/𝑛 entre sí, mientras que las máquinas asimétricas están formadas por grupos de devanados independientes desplazados entre ellos un ángulo eléctrico 𝜋/𝑛. Del mismo modo, las máquinas multifásicas se pueden clasificar por el número par o impar de fases que poseen [17, 18, 19] y si el número de fases que poseen es múltiplo de tres [20, 21, 22]. Entre las máquinas con un número par de fases, las máquinas de seis fases son las más usadas en el ámbito científico. Este tipo de máquinas pueden tener una distribución asimétrica (30°) o simétrica (60°) de devanados y uno o dos neutros. Sin embargo, la estructura más común se basa en dos juegos de devanados trifásicos asimétricos con dos neutros independientes, accionamientos usualmente denominados como máquinas con doble devanado trifásico asimétrico. Este tipo de máquinas han sido ampliamente investigadas, siendo posible encontrar trabajos centrados en su modelado [22], técnicas de control específicas (basadas en control orientado en campo [23, 24, 25, 26], control directo de par [27, 28] o control predictivo [29, 30]) o estrategias de modulación [31, 32, 33]. Por el contrario,
Capítulo 5 124 las máquinas con un número impar de fases (no múltiplo de tres) son a veces preferidas por su estructura simétrica. Este tipo de máquinas se construyen con devanados en configuración estrella, un único neutro y con devanados concentrados o distribuidos. El caso más habitual dentro de este grupo es el caso de la máquina de cinco fases, para las cuales se puede encontrar en la literatura científica diferentes tipos de técnicas de modulación y control, basadas en modulación por ancho de pulsos con portadora o modulación con vectores espaciales [34, 35, 36], control de campo orientado [13, 37, 38], control directo de par [39, 40] y control predictivo [41, 42], que buscan sacar provecho de las ventajas de las máquinas multifásicas, manteniendo tensiones sinusoidales o no sinusoidales, dependiendo del tipo de distribución de los devanados y modo de funcionamiento. Más aún, dependiendo de si el número de fases de la máquina es un número primo o no, es posible realizar diferentes conexiones en los devanados del estator, obteniendo máquinas con un neutro, múltiples neutros o con configuración poligonal. El efecto de la conexión de los devanados del estator bajo diferentes puntos de operación ha sido analizado en [43, 44, 45], donde se ha demostrado que es posible obtener diferentes prestaciones de operación de par/velocidad dependiendo del tipo de conexión de la máquina. Una máquina de 𝑛-fases puede ser conectada de ((𝑛+1)2 ⁄), configuraciones diferentes. Por ejemplo, una máquina de cinco fases puede ser conectado en configuración estrella, pentágono y poligonal. Dependiendo del tipo de conexión, la magnitud de la corriente y tensión que cae en los devanados, para una misma tensión de DC-Link y capacidad de potencia, varía. Es así como la tensión que cae sobre el devanado es mayor en las configuraciones de tipo poligonal o pentágono que en estrella, mientras que las corrientes son mayores en la conexión en estrella seguidas por la configuración en pentágono y poligonal, respectivamente. Debido a esto, la configuración en estrella permite obtener un alto par con baja velocidad, mientras que la configuración en pentágono proporciona menor par que la configuración en estrella pero con una mayor velocidad y la configuración poligonal proporciona una operación de alta velocidad pero a menor par que en los casos anteriores. Como se demuestra en [46, 47] es posible controlar múltiples máquinas multifásicas conectadas en serie desde un único convertidor de potencia, considerando ciertos cambios en el orden de las fases para desacoplar el par y flujo generados en las máquinas por las corrientes impuestas. Las configuraciones de los accionamientos multimotor han sido estudiadas con máquinas de cinco y seis fases [48, 49, 50], y considerando topologías con máquinas de diferente número de fases o tipo de máquina [51, 52]. Al implementar múltiples bucles de control de campo orientado (FOC por sus siglas
Resumen en Español de la Tesis Doctoral 125 en inglés), uno por cada par de corrientes según la descomposición en espacios vectoriales (VSD por sus siglas en inglés), es posible aprovechar los grados de control adicionales que las máquinas multifásicas poseen y controlar, por ejemplo, dos máquinas independientes con un único variador de cinco fases. La disposición de los devanados entre las máquinas se realiza de tal forma que la corriente en ejes 𝑑-𝑞 de una de las máquinas representa la corriente en coordenadas 𝑥-𝑦 para otra, en la que su valor no tiene influencia en la producción de par, y viceversa. Es así como las corrientes 𝑑-𝑞 son utilizadas para controlar la producción de par y flujo en la primera máquina mientras que las corrientes en 𝑥-𝑦 son usadas, de manera similar, para la producción de par y flujo en la segunda máquina. Cabe resaltar que la configuración multimotor genera un incremento en las perdidas en el cobre y no posee tolerancia a fallos, debido a que los grados de libertad necesarios para la operación post-falta son empleados para controlar independientemente cada una de las máquinas. Asimismo la configuración de variadores multimotor es sólo válida para accionamientos con bobinados distribuidos y no es posible con máquinas de devanados concentrados, en los que las corrientes en 𝑥-𝑦 generarían par y, por consiguiente, no sería posible controlar independientemente cada máquina. En general, se puede decir que los accionamientos multifásicos constituyen una tecnología interesante, formada por un gran número de máquinas y convertidores de potencia, y con características especiales que las hacen interesantes en aplicaciones industriales concretas como pueden ser los casos del transporte eléctrico y la generación de energía, lo que justifica el interés actual por esta tecnología a nivel de investigación, y en la búsqueda de estándares industriales y de seguridad válidos que permitan aprovechar los beneficios de este tipo de máquinas a precios competitivos de mercado. 5.5 CONTRIBUCIONES Esta tesis doctoral se centra en la extensión del control predictivo de estados finitos basado en modelo (FCS-MPC por sus siglas en inglés) para accionamientos multifásicos a la operación tolerante a fallos, asegurando un funcionamiento eficiente y controlado en situación post-falta. Con el fin de contar con un modelo preciso del sistema en situación de falta, adecuado para una estrategia FCSMPC, se realizaron trabajos de investigación en el estudio matemático de las ecuaciones del modelo de la máquina en condiciones de pre- y postfalta considerando diferentes tipos de faltas, permitiendo establecer el efecto que las condiciones de fallo tienen en el comportamiento del sistema. Se
Capítulo 5 126 desarrollaron modelos de simulación de una máquina de inducción de cinco fases, considerando faltas de fase abierta y en el disparo de los IGBT’s de una fase, permitiendo el diseño y validación del controlador FCS-MPC tolerante a fallos, donde los resultados obtenidos fueron presentados en diversos congresos internacionales. La posterior implementación y validación experimental del control tolerante a fallos propuesto (en la bancada de pruebas del laboratorio), dio lugar a la publicación de dos de los artículos científicos presentados en esta tesis. Del mismo modo, se desarrolló un control tolerante a fallos basado en controladores lineales (de tipo resonante), teniendo en cuenta los esquemas propuestos en publicaciones científicas recientes y se realizó una comparativa entre el control tolerante a fallos basado en FCS-MPC y el controlador resonante ante un fallo de fase abierta, mediante resultados de simulación y experimentales, dando lugar a la publicación en un congreso internacional y en un artículo de revista científica. Las principales contribuciones de esta tesis han sido aceptadas y se han publicado como trabajos de investigación en la revista científica IEEE Transactions on Industrial Electronics entre los años 2013/2015. A continuación, se realiza un resumen de cada uno de los artículos publicados, resaltando sus aspectos más importantes. 5.5.1 CONTROL TOLERANTE A FALLOS BASADO EN FCSMPC PARA ACCIONAMIENTOS MULTIFÁSICOS ANTE UN FALLO DE FASE ABIERTA En el primer artículo científico titulado, “Speed Control of Five-Phase Induction Motors with Integrated Open-Phase Fault Operation using Model-Based Predictive Current Control Techniques”, se presenta un nuevo control predictivo basado en FCS-MPC para la operación post-falta de un accionamiento de cinco fases ante el fallo de una fase abierta (Fig. 3.1). El funcionamiento del control basado en FCS-MPC depende en gran medida de la precisión del modelo del sistema utilizado y, por consiguiente, del modelo matemático del accionamiento multifásico en situación de falta considerado. Se desarrolló un modelo detallado del accionamiento multifásico con una fase abierta y se establecieron los efectos del fallo en las ecuaciones del modelo de la máquina de inducción de cinco fases. Se estableció que el fallo de una fase abierta genera términos asimétricos en las impedancias del estator y del rotor (en el plano α-β), generando a su vez corrientes no circulares de estator en el plano α-β (Fig. 3.2b). En este caso la corriente en la fase en fallo es cero, mientras que su tensión es ahora dada por el término de la fuerza contra electromotriz
Resumen en Español de la Tesis Doctoral 127 (Back-EMF por sus siglas en inglés). Por consiguiente, la tensión del neutro de la máquina oscila y la matriz de tensiones de fase debe ser modificada de tal forma que considere este efecto. Para manejar los términos asimétricos, se ha propuesto una matriz modificada de Clarke (150) que mantiene los componentes de impedancia de rotor/estator y Back-EMF circulares en el plano αβ (Fig. 3.2c). La principal ventaja que presenta la utilización de la matriz propuesta (150), al compararla con diferentes trabajos de investigación publicados hasta la fecha, es que su implementación permite obtener términos simétricos sin la necesidad de contar con una matriz de rotación modificada, simplificando su implementación y reduciendo el número de cambios a realizar en el control para la operación post-falta. [𝑇𝑐_𝑚𝑜𝑑]=25[cos(𝜗)−1 cos(2𝜗)−1 cos(3𝜗)−1 cos(4𝜗)−1 sin(𝜗)sin(2𝜗)sin(3𝜗)sin(4𝜗) sin(2𝜗)sin(4𝜗)sin(6𝜗)sin(8𝜗) 1 1 1 1 ] (150) Del mismo modo es necesario tener en cuenta en el modelo del accionamiento multifásico la oscilación de la tensión del punto neutro durante la operación post-falta, con el fin de asegurar que el controlador FCS-MPC cuenta con un modelo detallado del sistema que le permita elegir el vector de tensión apropiado. Para ello, el término de la Back-EMF de la fase en fallo es incluida en la matriz de tensiones (151), dada por el segundo término y dependiente de la corriente de estator y rotor en el eje α. [𝑣𝑏𝑠 𝑣𝑐𝑠 𝑣𝑑𝑠 𝑣𝑒𝑠]=𝑉𝑑𝑐 4[3 −1 −1 −1 −1 3 −1 −1 −1 −1 3 −1 −1 −1 −1 3][𝑆𝑏 𝑆𝑐 𝑆𝑑 𝑆𝑒]−𝐿𝑚𝑑𝑖𝑠𝛼 𝑑𝑡+𝐿𝑚𝑑𝑖𝑟𝛼 𝑑𝑡 4[𝐼4] (151) Una vez desarrollado el modelo matemático del sistema en situación de fallo, se diseñó el control basado en FCS-MPC. El controlador diseñado está formado por un bucle externo de velocidad y un bucle interno predictivo en corriente. El controlador predictivo en corriente fue diseñado e implementado para trabajar en situaciones de pre- y postfalta, con el fin de demostrar su capacidad de funcionar en pre- o postfalta y de gestionar el sistema durante el transitorio asociado a la aparición del fallo. Cabe resaltar que la función de coste J es la misma en situación de pre- o postfalta: 𝐽=𝐴|𝑖𝑠𝛼 |+𝐵|𝑖𝑠𝛽 |+𝐶|𝑖𝑠𝑥 |+𝐷|𝑖𝑠𝑦 | (152) Donde los términos A, B, C, D representan el peso de cada variable en la función de coste y cada término de corriente en los ejes 𝛼-𝛽-𝑥-𝑦, se definen como: 𝑖𝑠𝛼 =𝑖𝑠𝛼 ∗(𝑘+1)−𝑖𝑠𝛼(𝑘+1),𝑖𝑠𝛽 =𝑖𝑠𝛽 ∗(𝑘+1)−𝑖𝑠𝛽(𝑘+1) (153)
Capítulo 5 128 𝑖𝑠𝑥 =𝑖𝑠𝑥 ∗(𝑘+1)−𝑖𝑠𝑥(𝑘+1),𝑖𝑠𝑦 =𝑖𝑠𝑦 ∗(𝑘+1)−𝑖𝑠𝑦(𝑘+1) (154) Únicamente el factor C para la corriente en la componente x debe ser modificado, siendo igual a cero durante la operación post-falta. Se adoptaron dos criterios de control para el funcionamiento post-falta, “Minimum Copper Loss” y “Minimum Derating”, denotados como ML y MD, respectivamente. Según el criterio seleccionado, las referencias de corriente en post-falta cambian, tal y como se presenta en la Fig. 3.1, donde se muestra que en ambos criterios la referencia de corriente del eje x queda fija a −𝑖𝑠𝛼, mientras que la referencia de corriente en el eje y es cero para el criterio de ML y −26.31% de la componente de corriente en el eje 𝛽 para el de MD. Los resultados obtenidos permiten concluir que la implementación del criterio MD permite al accionamiento eléctrico generar un par eléctrico máximo un 8% superior al alcanzado con el criterio de ML, siendo el par máximo alcanzable en post-falta con el criterio de ML un 56% del par nominal de la máquina en pre-falta y un 64% con el criterio de MD. Cabe resaltar, que aunque la detección de faltas no se ha considerado en esta tesis doctoral, el efecto que tiene el retraso entre el momento en que sucede la falta, su detección y la reconfiguración del control para el funcionamiento post-falta, se ha considerado en algunos de los ensayos experimentales realizados. Teniendo en cuenta el tiempo estimado en que se demora un sistema en detectar un fallo, según la literatura científica disponible hasta el momento, se tomó un tiempo de transición entre pre- y postfalta de 40 ms. Los resultados obtenidos permiten concluir que aunque el controlador predictivo ofrece una adecuada operación post-falta si ésta es detectada de manera casi instantánea, el controlador pierde por completo la capacidad de control durante el tiempo de transición debido a la diferencia que existe entre el modelo utilizado en el FCS-MPC y el sistema físico en situación de fallo. 5.5.2 FALLO EN EL DISPARO DE LOS IGBT’S EN ACCIONAMIENTOS DE INDUCCIÓN MULTIFÁSICOS TOLERANTES A FALLOS En el segundo artículo científico titulado “IGBT-Gating Failure Effect on a Fault-Tolerant Predictive Current Controlled 5-Phase Induction Motor Drive”, se analiza un segundo tipo de fallo en el accionamiento multifásico. El efecto que tiene el fallo en el disparo de los dos IGBT’s de una misma fase, perdiendo su capacidad de encender y por lo tanto la controlabilidad de una rama, es analizada desde el punto de vista teórico y experimental. Se demostró que los diodos de libre
Resumen en Español de la Tesis Doctoral 129 circulación de la fase en fallo (D1 y D2) son capaces de conducir en diferentes instantes de tiempo durante este tipo de faltas, conectando la fase en fallo al bus negativo (N) o positivo (P) del convertidor si las condiciones (155)-(157) se cumplen. Este efecto genera la circulación de corrientes no controladas en la fase en fallo. Como consecuencia, la topología del accionamiento eléctrico estará cambiando constantemente, pasando de un sistema de cuatro fases (variador de cinco fases con una fase abierta) a un sistema con cuatro fases controladas y una no controlada (Fig. 3.3), generándose debido al fallo una oscilación en la tensión de neutro del estator que debe ser considerada en la estrategia de control. 𝐷1−𝑂𝑁:𝑉𝐷1=𝑣𝑎𝑠+𝑉𝐶𝑀−0.5𝑉𝐷𝐶≥𝑉𝛾 (155) 𝐷2−𝑂𝑁:𝑉𝐷2=𝑣𝑎𝑠+𝑉𝐶𝑀+0.5𝑉𝐷𝐶≤−𝑉𝛾 (156) 𝑉𝐶𝑀=𝑉𝑠𝑁−𝑉𝐷𝐶 2=15(𝑉𝑎𝑁+𝑉𝑏𝑁+𝑉𝑐𝑁+𝑉𝑑𝑁+𝑉𝑒𝑁)−𝑉𝐷𝐶 2 (157) Donde VD1 y VD2 representan la tensión que cae sobre cada uno de los diodos de libre circulación, Vγ la tensión de conducción del diodo, vas es la tensión entre el punto medio de la rama y el neutro de la máquina, VsN es la tensión entre el punto neutro de la máquina (s) y el bus negativo del convertidor, dado por la suma de la tensión a la salida de la rama del inversor (𝑖=𝑎,𝑏,𝑐,𝑑,𝑒) con respecto a N, y VCM es la tensión de modo común (CMV) que relaciona la tensión entre el punto neutro de la máquina y el punto medio del DC-Link. En general, cuando este tipo de faltas ocurren, la fase en fallo es desconectada de la máquina eléctrica, reconfigurando el variador multifásico para funcionar con el fallo de fase abierta. Sin embargo, esta estrategia requiere de componentes eléctricos adicionales en el convertidor para poder desconectar físicamente la fase del convertidor de la máquina eléctrica que falló, incrementando el coste y la complejidad del convertidor de potencia. Se propone por el contrario la gestión de este tipo de faltas mediante técnicas de control, reduciéndose así complejidad y costes extra, a cambio de la aparición de una oscilación no controlada en la tensión del neutro del estator. Como se ha comentado anteriormente, los controladores de tipo predictivo necesitan un modelo detallado del sistema a controlar. Por tanto, el cambio en la configuración de la topología del accionamiento eléctrico durante la gestión del fallo hace que la descripción del sistema cambie en función de la presencia o no del mismo, siendo más compleja y aumentando el coste computacional de la estrategia de control. Sin embargo, al analizar los vectores de tensión disponibles en situación post-falta se puede concluir que el efecto que tiene la fase no controlada resulta en una pequeña desviación de los vectores disponibles después del fallo de fase abierta, bien a la izquierda o a la
Capítulo 5 130 derecha, dependiendo del diodo de libre circulación que esté conduciendo. Por ello, el uso del controlador FCS-MPC tolerante a fallos de fase abierta, podría ser utilizado también para controlar el accionamiento multifásico durante fallos en los disparos de los IGBT’s de una fase a cambio de una pequeña disminución en sus prestaciones. La capacidad de controlar este tipo de faltas mediante el controlador FCS-MPC tolerante a fallos se demostró experimentalmente considerando diferentes puntos de operación (i.e. estado estable, cambio en la velocidad de referencia y la transición de pre- a postfalta) y los criterios de ML y MD, bajo diferentes valores de par de carga y en algunos ensayos con retrasos en la detección y reconfiguración a post-falta de 40 ms. Con el fin de determinar la disminución de las prestaciones del controlador, se realizaron ensayos en los mismos puntos de operación considerando faltas de fase abierta y de disparo en los IGBT’s, permitiendo determinar el efecto que tiene el no considerar un modelo detallado del sistema en el FCS-MPC en el caso del fallo en los disparos de los IGBT’s. En general, se deduce que la corriente no controlada a través de los diodos de libre circulación reduce ligeramente el par de carga máximo alcanzable, incrementando las pérdidas en el cobre. Más aún, esta reducción en el par de carga máximo alcanzable en post-falta es mayor si se considera el tiempo de transición entre la detección del fallo y la reconfiguración del control. Sin embargo, si el accionamiento multifásico no se encuentra trabajando en el máximo punto de operación en post-falta, el efecto es despreciable. Como consecuencia, la degradación en las prestaciones del control es limitada y puede ser considerada como aceptable si se considera el coste computacional y el aumento en la complejidad de implementación de un modelo detallado del accionamiento con fallo en los disparos de los IGBT’s. 5.5.3 ANÁLISIS COMPARATIVO ENTRE CONTROLES TOLERANTES A FALLOS BASADOS EN FCS-MPC Y CONTROLES LINEALES Finalmente, en el tercer artículo científico titulado “Comparative Study of Predictive and Resonant Controllers in Fault-Tolerant Five-phase Induction Motor Drives” se realiza un análisis comparativo entre el control tolerante a fallos basado en FCS-MPC con un control lineal de tipo resonante ante un fallo de fase abierta, mediante una serie de ensayos experimentales (i.e. estado estable, cambio en la velocidad de referencia y transición entre pre- y postfalta). Los ensayos realizados se llevaron a cabo operando el accionamiento multifásico con el máximo para de carga
Resumen en Español de la Tesis Doctoral 131 post-falta establecido según cada criterio de control, siendo este de (TL=0.56*Tn) para el criterio de ML y de (TL=0.64*Tn) para el criterio de MD, considerando además la operación en estado estable y la transición de pre- a postfalta con y sin retraso en la detección y reconfiguración del control después de la falta. Aunque los dos controladores son capaces de asegurar una correcta operación post-falta, manteniendo una MMF circular, alcanzando mínimas perdidas y máximo par por amperio y reduciendo las vibraciones del par, su implementación es completamente diferente debido a los efectos que tienen las asimetrías en las ecuaciones de la máquina en post-falta en cada estrategia de control. En el caso del control basado en FCS-MPC (Fig. 3.1), el modelo del accionamiento multifásico debe ser modificado para incluir el efecto que tiene el fallo en las ecuaciones del sistema de forma tal que el controlador pueda proporcionar predicciones más precisas. Por consiguiente, se utiliza una transformación modificada de Clarke para compensar las asimetrías de la máquina en el espacio α-β y la fuerza contra electromotriz es considerada para la estimación del vector de tensión. Por otro lado, si se implementa la estrategia basada en control lineal (Fig. 3.4), el modelo de la máquina eléctrica y la descomposición de vectores espaciales se mantienen como en pre-falta debido a que la asimetría en las impedancias de la máquina en el espacio α-β no afectan el funcionamiento del controlador y no es necesario considerar la Back-EMF en las ecuaciones de tensión. Sin embargo, es necesario implementar reguladores de tipo resonante (PR por sus siglas en inglés) para poder controlar las referencias de corriente oscilantes en el eje x-y. Con el fin de comparar el funcionamiento de los controladores bajo las mismas condiciones de funcionamiento, se implementaron como se muestra en la Fig. 3.1 y Fig. 3.4, tanto en precomo en postfalta, con un bucle externo de control (FOC) de velocidad y flujo en el eje d-q con reguladores PI convencionales. La referencia de corriente en d se fija a un valor constante y el valor de referencia en q es determinado por un controlador PI basado en el error entre la velocidad medida y la de referencia. Durante el funcionamiento pre-falta, las referencias de corriente en x-y son cero, utilizándose controladores PI en el esquema de control para estas componentes. En el caso del controlador predictivo y pre-falta, se emplean la matriz de transformación de Clarke, la matriz de tensión convencional y la función de coste que considera las corrientes en x-y. Cuando sucede el fallo, el bucle de control interno de cada esquema de control es modificado de forma tal que pueda operar en situación de post-falta, utilizando reguladores PR para las componentes x-y en el control lineal y modificando el esquema FCS-MPC según lo presentado en la sección 5.5.1.