scieee AI-readable full text Open interactive document viewer

Removal of Estrogenic Compounds from Filtered Secondary Wastewater Effluent in a Continuous Enzymatic Membrane Reactor. Identification of Biotransformation Products

Lloret, Lucía; Eibes González, Gemma María; Moreira Vilar, María Teresa; Feijoo Costa, Gumersindo; Lema Rodicio, Juan Manuel

Abstract

In the present study, a novel and efficient technology based on the use of an oxidative enzyme was developed to perform the continuous removal of estrogenic compounds from polluted wastewaters. A 2 L enzymatic membrane reactor (EMR) was successfully operated for 100 h with minimal requirements of laccase for the transformation of estrone (E1), 17β-estradiol (E2), and 17α-ethinylestradiol (EE2)from both buffer solution and real wastewater (filtered secondary effluent). When the experiments were performed at high and low concentrations of the target compounds, 4 mg/L and 100 μg/L, not only high removal yields (80–100%) but also outstanding reduction of estrogenicity (about 84–95%) were attained. When the EMR was applied for the treatment of municipal wastewaters with real environmental concentrations of the different compounds (0.29–1.52 ng/L), excellent results were also achieved indicating the high efficiency and potential of the enzymatic reactor system. A second goal of this study relied on the identification of the transformation products to elucidate the catalytic mechanism of estrogens’ transformation by laccase. The formation of dimers and trimers of E1, E2, and EE2, as well as the decomposition of E2 into E1 by laccase-catalyzed treatment, has been demonstrated by liquid chromatography atmospheric pressure chemical ionization (LC-APCI) analysis and confirmed by determination of accurate masses through liquid chromatography electrospray time-of-flight mass spectrometry (LC-ESI-TOF). Dimeric products of E2 and EE2 were found even when operating at environmental concentrations. Moreover, the reaction pathways of laccase-catalyzed transformation of E2 were proposed.

Full text

1 1 2 3 4 Removal of estrogenic compounds from filtered secondary wastewater effluent in a 5 continuous enzymatic membrane reactor. Identification of biotransformation products 6 7 Lucia Lloret*, Gemma Eibes, M. Teresa Moreira, Gumersindo Feijoo, Juan M. Lema 8 Dept. of Chemical Engineering, School of Engineering, University of Santiago de 9 Compostela, E-15782 Santiago de Compostela, Spain 10 11 12 13 14 15 16 17 *Corresponding author: Tel.: +34881816771 +; fax: +34881816702 18 E-mail address: [email protected] 19 20 21 2 ABSTRACT 22 In the present study, a novel and efficient technology based on the use of an oxidative enzyme 23 was developed to perform the continuous removal of estrogenic compounds from polluted 24 wastewaters. A 2-L enzymatic membrane reactor (EMR) was successfully operated for 100 h 25 with minimal requirements of laccase for the transformation of estrone, 17β-estradiol and 26 17α-ethinylestradiol from both buffer solution and real wastewater (filtered secondary 27 effluent). When the experiments were performed at high and low concentrations of the target 28 compounds, 4 mg/L and 100 µg/L, not only high removal yields (80-100%) but also 29 outstanding reduction of estrogenicity (about 84-95%) were attained. When the EMR was 30 applied for the treatment of municipal wastewaters with real environmental concentrations of 31 the different compounds (0.29-1.52 ng/L), excellent results were also achieved, indicating the 32 high efficiency and potential of the enzymatic reactor system. A second goal of this study 33 relied on the identification of the transformation products to elucidate the catalytic mechanism 34 of estrogens transformation by laccase. The formation of dimers and trimers of E1, E2 and 35 EE2, as well as the decomposition of E2 into E1 by laccase-catalyzed treatment has been 36 demonstrated by liquid chromatography atmospheric pressure chemical ionization (LC-APCI) 37 analysis and confirmed by determination of accurate masses through liquid chromatography 38 electrospray time-of-flight mass spectrometry (LC-ESI-TOF). Dimeric products of E2 and 39 EE2 were found even when operating at environmental concentrations. Moreover, the reaction 40 pathways of laccase-catalyzed transformation of E2 were proposed. 41 42 43 Keywords: Laccase; Bioremediation; Continuous bioreactor; Wastewaters; Transformation 44 products 45 46 3 INTRODUCTION 47 Over the past decades public concern about the environmental impact of steroid estrogens has 48 grown due to their negative effects associated to the disruption of the endocrine system in 49 humans and animals.1,2 The presence of this type of compounds in the environment has been 50 mainly attributed to their incomplete removal by conventional biological and physicochemical 51 processes in wastewaters treatment plants (WWTP),1 being the natural compounds estrone 52 (E1) and 17β-estradiol (E2) and the synthetic compound 17α-ethinylestradiol (EE2) the major 53 contributors to the estrogenic activity detected in the WWTP effluents.3 Therefore, recent 54 works have been focused on the development of advanced oxidation processes such as 55 ozonation and chlorination. These alternatives provide satisfactory removal yields although 56 they present important disadvantages such as high costs and formation of by-products with 57 unknown estrogenicity, which may be even higher than that of the original compound.4-6 58 Hence, an effective method is required to fulfill the challenge of their removal. 59 In this way, the enzymatic treatment is a potential alternative for the removal of estrogens due 60 to its low energy requirements and easy control and operation.7 Indeed, several previous 61 researchers have studied the transformation of E1, E2 and EE2 by ligninolytic enzymes, being 62 laccase (EC 1.10.3.2, benzenodiol: oxygen oxidoreductase) the most widely applied 63 biocatalyst due to its potential ability to degrade recalcitrant compounds and its simple 64 catalytic mechanism using oxygen as a final electron acceptor.8 Previous works reported 65 significant removal yields of both the target compounds and their estrogenic activities.1,4,7,9-14 66 Nevertheless, most of those experiments were conducted at relatively high concentrations in 67 synthetic media, while only a few investigations assessed the removal of estrogens in real 68 wastewaters.1 Furthermore, research has been focused in the operation in batch mode, whilst 69 relative low effort has been devoted for its implementation in a continuous process. Thus, the 70 4 design and operation of a novel technology for the continuous application of enzymatic 71 remediation under more realistic conditions is still a pending objective. 72 We have previously developed a lab-scale enzymatic membrane reactor (EMR) based on a 73 continuous stirred tank reactor coupled to an ultrafiltration membrane for the continuous 74 elimination of E1 and E2 at high initial concentrations from a buffer solution by high doses of 75 laccase obtaining promising results.6 Besides, this technology presents several advantages 76 such as reuse of the biocatalyst, easy addition of fresh enzyme in case of deactivation, high 77 flow rates, reduced energy requirements, simple operation and control and straightforward 78 scale-up.15,16 Thus, this enzymatic reactor can be particularly useful when performing the 79 continuous treatment of real wastewaters by laccase at larger-scale (2-L EMR) and much 80 lower initial concentrations of estrogens and enzyme. Indeed, integrate systems including 81 filtration are considered nowadays one of the most promising technologies used for the 82 advanced treatment of secondary effluents, being both micro and ultrafiltration membranes 83 techniques widely used as tertiary treatments.17-19 84 Furthermore, an evident lack of knowledge exists with regard to the identification of laccase-85 catalyzed transformation products of estrogens, in spite of being this enzyme so extensively 86 tested over the past years. The elimination of estrogens has been assumed to occur by means 87 of polymerization reactions.1,13,14 However, only few works supported this hypothesis by 88 means of the corresponding experimental assays and analytical techniques: Nicotra et al. and 89 Tanaka et al. reported the formation of dimers of E2 and EE2, respectively;11,12 whilst no 90 other degradation products were identified and by-products resulting from laccase-catalyzed 91 oxidation of E1 have not been characterized up to the date. 92 To sum up, the key objective of this research was to establish and operate an efficient laccase-93 based bioreactor for the continuous removal of estrogenic compounds present in real 94 wastewaters. The EMR was applied for the treatment of both buffer solution and real 95 5 wastewater (filtered secondary effluent) at high and low as well as at environmental 96 conditions. A second goal relied on the identification of transformation products and the 97 proposal of reaction pathways to elucidate the catalytic mechanism of estrogens 98 transformation by laccase. 99 100 EXPERIMENTAL SECTION 101 Chemicals 102 All chemicals were of analytical grade. Estrogens: estrone (E1), 17β-estradiol (E2) and 17α-103 ethinylestradiol, were obtained from Sigma-Aldrich (USA). Deuterated 17β-estradiol (E2-d4), 104 deuterium was introduced in positions 2, 4 and 16, was purchased from Cambridge Isotope 105 Laboratories (USA). 2,2´-azinobis-(3-ethylbenzothiazoline-6-sulfonate) (ABTS) was supplied 106 from Fluka (USA). Stock solutions of E1, E2, EE2 and E2-d4 were prepared in methanol 107 (J.T. Baker, HPLC grade, 99.8%). Commercial laccase from Myceliophthora thermophila (56 108 kDa) was supplied by Novozymes (Denmark). 109 110 Reactor design and Experimental procedure 111 A continuous enzymatic membrane reactor (EMR) was operated for the enzymatic removal of 112 natural (E1 and E2) and synthetic (EE2) estrogens. The system was based on a previous 113 design and consisted of a tank reactor coupled to an ultrafiltration polyethersulfone membrane 114 (Prep/Scale-TFF Millipore) with a nominal molecular weight cutoff of 10 kDa.6 The influent 115 containing the mixture of the estrogens was continuously fed into the tank by a peristaltic 116 pump, while the laccase was added in a single initial pulse. An additional pump was used to 117 circulate the reaction solution from the tank to the membrane, where the enzyme was retained 118 and continuously recycled to the reactor at a recycling:feed flow ratio 12:1. A valve located in 119 the membrane module permitted the control of both effluent and recycling flow rates. PTFE 120 6 tubing was used to avoid the adsorption of the target compounds to the inner surface of the 121 tubing. 122 Once the feasibility of a lab-scale reactor of 250 mL of volumen has been previously 123 demonstrated,6 a larger-scale bioreactor (2 L) was used in the current work (Biostat® MD, B. 124 Braun-Biotech International), which was equipped with pH, temperature and pO2 sensors, as 125 well as with mechanical stirring. An electrovalve located at the end of a flexible membrane 126 tube controlled by a cyclic timer was used to inject oxygen with a pulsing flow of 1 bar for 30 127 s each 30 min of operation time. Temperature was maintained at 26ºC by circulating 128 thermostated water through the reactor chamber and the reaction mixture was continuously 129 stirred at 250 rpm. A scheme of the bioreactor is shown in Figure S1 (Supporting 130 Information). 131 The hydraulic residence time (HRT) was 4 h, which meant an inlet flow rate of 8.3 mL/min. 132 Besides, an initial laccase activity of 100 U/L was assayed. The reactor was operated for 100 133 h in order to demonstrate the viability of the technology and the stability of both the 134 membrane and the biocatalyst. Samples were withdrawn at different periods from the reaction 135 vessel in order to measure laccase activity, as well as from the effluent to determine both the 136 estrogens concentration and the estrogenic activity. The performed experiments and the 137 corresponding operational conditions are presented in Table 1. 138 The performance of the technology was evaluated in terms of the removal percentage (%) of 139 both target compounds and estrogenicity, as well as by the estrogens removal rates (mg, µg or 140 ng degraded per volume of reactor and time). Corresponding controls lacking laccase were 141 performed under the conditions examined in each removal experiment. 142 The real wastewater used was collected from the outlet of the secondary clarifier of the 143 municipal wastewater treatment plant of Calo-Milladoiro (Ames, Spain). This water was 144 filtered (0.45 µm) to remove particulate matter and suspended solids which could contain 145 7 bacteria and other microorganisms, to avoid undefined biological transformation or even 146 adsorption of the target compounds, and thus examining the sole role of the laccase, and then 147 it was stored at 4ºC until its use. The wastewater was analyzed according to Standard 148 Methods20 and the main characteristics are summarized in Table S1. 149 150 Enzymatic activity 151 Laccase activity was determined by measuring the oxidation of 5 mM ABTS to its cation 152 radical (ABTS+) at 436 nm in 100 mM sodium acetate buffer, pH 5 and 30 ºC (ε436 = 153 29,300M−1·cm−1) using a Shimadzu UV-1603 spectrophotometer. One unit (U) of activity was 154 defined as the amount of enzyme forming 1 µmol of ABTS+ per min. 155 156 Evaluation of estrogenic activity 157 The estrogenic activities of the inlet and outlet streams of the reactor were measured by LYES 158 (lyticase yeast estrogen screen assay) using recombinant yeast Saccharomyces cerevisae. This 159 method has been adapted from one developed by Schultis and Metzger and described 160 elsewhere.6,21 161 162 Estrogens analysis 163 All the analytical methods applied are detailed in Supporting Information. 164 The determination of the estrogens concentrations in the Experiment 1 (high initial estrogens 165 concentration in buffered solution) was carried out by high performance liquid 166 chromatography (HPLC) using a diode array detector. 167 The samples withdrawn during the Experiments 2 and 3 (low initial concentrations in buffer 168 solution or real wastewater) were analyzed by gas chromatography-mass spectrometry (GC-169 MS). First, samples of 20 mL were acidified at pH 2, diluted in distilled water (pH 2 adjusted 170 8 with HCl) until a final volume of 100 mL and filtered (0.45 µm). Then, the solid phase 171 extraction (SPE) was carried out with 60 mg OASIS HLB cartridges (Water closet, USA) 172 previously conditioned with 3 mL of ethyl acetate, 3 mL of methanol and 3 mL of distilled 173 water (pH 2). The cartridges were then dried with nitrogen for 45 min and eluted with 3 mL 174 of ethyl acetate. BSTFA (N,O-bis(trimethylsisyl)trifluoroacetamide) was added for the 175 derivatization of the species. Afterwards, the resulting samples were analyzed by GC-MS. 176 The concentrations of estrogens present in the real wastewater samples used as well as in the 177 samples withdrawn during the Experiment 4 (environmental concentrations) were determined 178 by liquid chromatography atmospheric pressure chemical ionization tandem mass 179 spectrometry (LC-APCI-MS-MS). Aiming to deeply concentrate the samples, volumes of 2 L 180 (wastewater samples) or 5 L (samples after laccase-catalyzed treatment) were collected for 181 their subsequent extraction and concentration to 3 mL by SPE as described above. Then, 2 182 mL of the resulting samples were evaporated under gentle stream of nitrogen prior to 183 resuspension in methanol; finally, further concentration by nitrogen was conducted until 184 obtaining 50 µL-samples. Concentrations of estrogens quantified in these samples were 185 corroborated by using E2-d4 as internal standard aiming to correct for matrix effects, as 186 indicated in Supporting Information. 187 188 Identification of laccase-catalyzed reaction products 189 With the objective of identifying the oxidation products and establishing the transformation 190 pathways, experiments were conducted in batch reactors of 250 mL. Each reactor contained 191 100 mL of 5 mg/L of each estrogen in distilled water. An initial laccase activity of 2,000 U/L 192 was used aiming to ensure the degradation of the compounds and the consequent formation of 193 reaction products at significant concentrations. Each estrogen was assessed separately in order 194 9 to identify the corresponding transformation products. The reaction was conducted for 24 h 195 and then the mixture was acidified to a final pH of 2 to inactivate the enzyme. 196 These acidified samples as well as acidified samples corresponding to time 0 (before the 197 enzyme addition and analogous to samples after 24 h of controls lacking enzyme) and a blank 198 with enzyme (after 24 of incubation in buffer solution) were analyzed by the LC-APCI 199 method used for the quantification of estrogens. However, for this study the mass 200 spectrometer was used in the full scan mode rather than in the tandem MS-MS mode, and the 201 range selected for the mass spectrometer full scan was between m/z ratios of 50 and 900. 202 Furthermore, samples were analyzed by liquid chromatography electrospray time-of-flight 203 mass spectrometry (LC-ESI-TOF) in negative mode by the method detailed in Supporting 204 Information, aiming to determine accurate masses of the biotransformation products to 205 confirm their proposed structures. 206 207 RESULTS AND DISCUSSION 208 Continuous removal of estrogens in an enzymatic membrane reactor 209 A 2-L EMR was proposed for the continuous transformation of estrogens by free laccase, 210 once the feasibility of a similar 250-mL bioreactor for the removal of E1 and E2 by 500 U/L 211 of laccase had been previously reported.6 In the present work, the removal of not only these 212 natural compounds but also a synthetic estrogen (EE2) was attempted, and initial laccase 213 activity was decreased to 100 U/L to reduce the enzyme requirements. The experimental 214 conditions of the different performed assays are detailed in Table 1. 215 First, the EMR was fed with a buffer solution (phosphate buffer solution, pH 7) containing 216 high estrogens concentration (4 mg/L each) (Experiment 1) to study the effect of the change 217 of scale and the reduction of laccase activity. Removal percentages of 80, 87 and 85% of E1, 218 E2 and EE2, respectively, were attained under steady-state conditions, which implied 219 16 masses were in agreement with the calculated ones with errors varying from -5.2 to 4.1 ppm: 369 two E1 dimers were found to have accurate masses of 537.3037 and 537.3038, and E2 and 370 EE2 dimers and trimers had masses in the ranges 541.3315-541.3334 and 811.4942-811.4954 371 and 589.3312-589.3330 and 883.4949-883.4963, respectively (deprotonated compounds). 372 Also, these values fitted those found in literature.37,38 A larger number of dimeric and trimeric 373 compounds were detected by LC-ESI-TOF in comparison to LC-APCI analysis, probably 374 because a higher sensitivity of the method. 375 The novelty of this investigation relies on the successful characterization of different dimers 376 not only of E2 and EE2, but also of E1. Additionally, the formation of E2 and EE2 trimers as 377 well as the transformation of E2 into E1 by laccase-catalyzed treatment was demonstrated for 378 the first time. 379 The formation of dimers would be also expected after the treatment of environmental 380 concentrations considering the findings of previous investigations.33,38 Although the 381 identification by LC-APCI of coupling products in the samples collected from the EMR 382 effluent fed with secondary effluent aiming to verify that assumption was not possible, 383 probably due to the detection limits of the instrument, dimers of E2 and EE2 were 384 successfully identified by LC-ESI-TOF: products with accurate masses of 541.3343 and 385 541.3342 (C36H45O4) and 589.3330 (C40H45O4), respectively, were found with relative errors 386 from -3.7 to -1.2 ppm. Although the possibility of other reaction mechanisms could not be 387 discarded, these results indicated that laccase-catalyzed radical coupling reactions occur even 388 at such low concentrations. 389 390 Proposed reaction pathways 391 As mentioned, the formation of dimers and trimers suggests the elimination via radical 392 coupling reactions by laccase-catalyzed oxidation of the substrates to generate free radicals, 393 17 which may couple covalently to each other subsequently. In fact, the products followed the 394 pattern of nMW-2(n-1), where n is the number of monomers and MW the mass of the parent 395 compound. However, it is interesting to highlight that in the case of E1 and E2, other species 396 having smaller MW than the initial compounds were found, which may indicate that radical 397 coupling was not the only transformation via, but also different degradation mechanisms are 398 involved. 399 Reaction pathways were proposed for E2 since all the products detected by the applied 400 analytical methods after 24 h of laccase-catalyzed treatment of that compound were identified. 401 The suggested products structures and reactions pathways are schematized in Figure 2. 402 Regarding the oxidative radical-radical coupling, the reaction is initiated by the laccase-403 catalyzed formation of the primary oxidation product, by abstracting one electron from the –404 OH group of the original molecule. Thus, the free radical is formed and the unpaired electron 405 may delocalize through resonance to the respective conjugated positions (E2 radical 406 intermediates: compounds 1-3). Thereafter, the subsequent covalent bonding between radical 407 intermediates could occur through C-C or C-O bond formation. Mao et al. reported that 408 oxygen atoms have higher charges and lower spin density than carbon atoms, making bond 409 formation at these sites kinetically less favorable.35 Anyhow, both possibilities were 410 considered and the possible structures of the dimers are indicated as C-O and C-C dimeric 411 products in Figure 2 (compounds 4-7). 412 Due to the remaining laccase activity and that the coupling products are still substrates of the 413 enzyme due to their phenolic groups, radical coupling reaction can be further performed. 414 Thus, the abstraction of other electron from one of the –OH groups of the dimeric products 415 would occur. Once different dimeric products may have been formed and they present various 416 –OH groups, there exist several possibilities of forming dimer radical intermediates. For 417 instance, it is indicated in Figure 2 the radical intermediates formed from the C-O (compound 418 18 4) and C-C dimer (compound 6) products resulted from the abstraction of one electron of the 419 –OH groups indicated (marked with asterisks), to form the corresponding oxygen radicals 420 than can delocalize to carbon-located radicals (intermediates 8 and 9 for the C-O dimer and 421 intermediates 10 and 11 for C-C dimer). Afterwards, the presence of radical intermediates of 422 E2 in the reaction medium could lead to the formation of E2 trimers via radical-radical 423 coupling mechanism. As example of possible E2 trimers formed, the products resulted from 424 the covalent bonding between the second radical form of each pair of dimer radical 425 intermediates (compounds 9 and 11) and both radical forms 1 and 2 of E2 are shown 426 (compounds 12-15). 427 To our knowledge, the reaction pathways of laccase-catalyzed transformation of an estrogen 428 including dimers, trimers and E1 as a product of E2 degradation have been proposed and 429 demonstrated in this study for the first time. 430 431 ACKNOWLEDGEMENTS 432 This study was supported by the Spanish Ministry of Science and Innovation (MICINN, 433 CTQ2010-20258). The authors belong to the Galician Competitive Research Group 434 GRC2010/37. L. Lloret thanks the Spanish Ministry of Education for the FPU grant (AP2008-435 01954). G. Eibes thanks the Xunta de Galicia for an Angeles Alvariño contract. 436 437 SUPPORTING INFORMATION AVAILABLE 438 1) Scheme of the EMR used; 2) Characteristics of the filtered secondary effluent used; 3) 439 HPLC method for the analysis of estrogens at high concentration; 4) GC-MS method for the 440 analysis of estrogens at low concentrations; 5) LC-APCI-MS-MS method for the analysis of 441 estrogens at environmental concentrations; 6) Results corresponding to Experiments 1-2; 7) 442 TIC of 24-h samples and mass spectra of transformation products detected by LC-APCI; 8) 443 19 Determination of accurate masses by LC-ESI-TOF. This information is available free of 444 charge via the Internet at http://pubs.acs.org/. 445 446 REFERENCES 447 (1) Auriol, M.; Filali-Meknassi, Y.; Tyagi, R.D.; Adams, C.D. Laccase-catalyzed conversion 448 of natural and synthetic hormones from municipal wastewater. Water Res. 2007, 41 (15), 449 3281-3288. 450 (2) Blánquez, P.; Guieysse, B. Continuous biodegradation of 17β-estradiol and 17α-451 ethinylestradiol by Trametes versicolor. J. Hazard. Mater. 2008, 150 (2), 459-462. 452 (3) Leusch, F.D.L.; Chaoman, H.F.; Korner, W.; Gooneratne, S.R.; Tremblay, L.A. Efficacy 453 of an advanced sewage treatment plant in southeast Queensland, Australia, to remove 454 estrogenic chemicals. Environ. Sci. Technol. 2005, 39 (15), 5781-5786. 455 (4) Auriol, M.; Filali-Meknassi, Y.; Adams, C.D.; Tyagi, R.D. Natural and synthetic hormone 456 removal using horseradish peroxidise enzyme: Temperature and pH effects. Water Res. 2006, 457 40 (15), 2847-2856. 458 (5) Garcia, H.A.; Hoffman, C.M.; Kinney, K.A.; Lawler, D.F. Laccase-catalyzed oxidation of 459 oxybenzone in municipal wastewater primary effluent. Water Res. 2011, 45 (5), 1921-1932. 460 (6) Lloret, L.; Eibes, G.; Feijoo, G.; Moreira, M.T.; Lema, J.M. Degradation of estrogens by 461 laccase from Myceliophthora thermophila in fed-batch and enzymatic membrane reactors. J. 462 Hazard. Mater. 2012, 213-214, 175-183. 463 (7) Cabana, H.; Jones, J.P.; Agathos, S.N. Elimination of endocrine disrupting chemicals 464 using white rot fungi and their lignin modifying enzymes: a review. Eng. Life Sci. 2007, 7 (5), 465 429-456. 466 (8) Martinez, A.T.; Speranza, M.; Ruiz-Duenas, F.J.; Ferreira, P.; Camarero, S.; Guillen, F.; 467 Martinez, M.J.; Gutierrez, A.; del Rio, J.C. Biodegradation of lignocellulosics: microbial 468 20 chemical, and enzymatic aspects of the fungal attack of lignin. Int. Microbiol. 2005, 8 (3), 469 195-204. 470 (9) Lloret, L.; Eibes, G.; Lú-Chau, T.A.; Moreira, M.T.; Feijoo, G.; Lema, J.M. Laccase-471 catalyzed degradation of anti-inflammatories and estrogens. Biochem. Eng. J. 2010, 51 (3) 472 124-131. 473 (10) Auriol, M.; Filali-Meknassi, Y.; Adams, C.D.; Tyagi, R.D.; Noguerol, T.-N.; Piña, B. 474 Removal of estrogenic activity of natural and synthetic hormone from a municipal 475 wastewater: Efficiency of horseradish peroxidase and laccase from Trametes versicolor. 476 Chemosphere 2008, 70 (3), 445-452. 477 (11) Nicotra, S.; Intra, A.; Ottolina, G.; Riva, S.; Danieli, B. Laccase-mediated oxidation of 478 the steroid hormone 17β-estradiol in organic solvents. Tetrahedron Asymm. 2004, 15 (18), 479 2927-2931. 480 (12) Tanaka, T.; Tamura, T.; Ishizaki, Y.; Kawasaki, A.; Kawase, T.; Teraguchi, M.; 481 Taniguchi, M. Enzymatic treatment of estrogens and estrogen glucororide. J. Environ. Sci. 482 2009, 21 (6), 731-735. 483 (13) Tamagawa, Y.; Yamaki, R.; Hirai, H.; Kawai, S.; Nishida, T. Removal of estrogenic 484 activity of natural steroidal hormone estrone by ligninolytic enzymes from white rot fungi. 485 Chemosphere 2006, 65 (1), 97-101. 486 (14) Suzuki, K.; Hirai, H.; Murata, H.; Nishida, T. Removal of estrogenic activities of 17β-487 estradiol and ethinylestradiol by ligninolytic enzymes from white rot fungi. Water Res. 2003, 488 37 (8), 1972-1975. 489 (15) López, C.; Mielgo, I.; Moreira, M.T.; Feijoo, G.; Lema, J.M. Enzymatic membrane 490 reactor for the biodegradation of recalcitrant compounds. Application to dye decolourisation. 491 J. Biotechnol. 2002, 99 (3), 249-257. 492 21 (16) Katchalski-Katzir, E. Immobilized enzymes-learning from past success and failures. 493 Trends Biotechnol. 1993, 11 (11), 471-478. 494 (17) Zhu, H.; Wen, X.; Huang, X. Characterization of membrane fouling in a microfiltration 495 ceramic membrane system treating secondary effluent. Desalination 2012, 284, 324-331. 496 (18) Acero, J.L.; Benitez, F.J.; Leal, A.I.; Real, F.J.; Teva, F. Membrane filtration 497 technologies applied to municipal secondary effluents for potential reuse. J. Hazard. Mater. 498 2010, 177 (1-3), 390-398. 499 (19) Muthukumaran, S.; Nguyen, D.A.; Baskaran, K. Performance evaluation of different 500 ultrafiltration membranes for the reclamation and reuse of secondary effluent. Desalination 501 2011, 279 (1-3), 383-389. 502 (20) American Public Health Association (APHA). Standard Methods for the Examination of 503 Water and Wastewater. American Public Health Association Washington DC, USA, 20th, ed.; 504 Washington, DC, USA, 1999. 505 (21) Schultis, T.; Metzger, J.W. Determination of estrogenic activity by LYES-assay (yeast 506 estrogen screen-assay assisted by enzymatic digestion with lyticase). Chemosphere 2004, 57 507 (11), 1649-1655. 508 (22) Liao, B.Q.; Bagley, D.M.; Kraemer, H.W.; Leppard, G.G.; Liss, S.N. A review of 509 biofouling and its control in membrane separation bioreactors. Water Environ. Res. 2004, 76 510 (5), 425-436. 511 (23) Gaulke, L.S.; Strand, S.E.; Kalhorn, T.F.; Stensel, H.D. 17alpha-ethinylestradiol 512 transformation via abiotic nitration in the presence of ammonia oxidizing bacteria. Environ. 513 Sci. Technol. 2008, 42 (20), 7622-7627. 514 (24) Sheng, G.D.; Xu, C.; Xu, L.; Qiu, Y.P.; Zhou, H.Y. Abiotic oxidation of 17β-estradiol by 515 soil manganese oxides. Environ. Pollut. 2009, 157 (10), 2710–2715. 516 22 (25) Marfil-Vega, R.; Suidan, M.T.; Mills, M.A. Abiotic transformation of estrogens in 517 synthetic municipal wastewater: An alternative for treatment? Environ. Pollut. 2010, 158 518 (11), 3372-3377. 519 (26) Marfil-Vega, R.; Suidan, M.T.; Mills, M.A. Assessment of the abiotic transformation of 520 17β-estradiol in the presence of vegetable matter. Chemosphere 2011, 82 (10), 1468-1474. 521 (27) Marfil-Vega, R.; Suidan, M.T.; Mills, M.A. Assessment of the abiotic transformation of 522 17β-estradiol in the presence of vegetable matter-II: The role of molecular oxygen. 523 Chemosphere 2012, 87 (5), 521-526. 524 (28) Vanderford, B.J.; Pearson, R.A.; Rexing, D.J.; Snyder, S.A. Analysis of endocrine 525 disruptors, pharmaceuticals, and personal care products in water using liquid 526 chromatography/tandem mass spectrometry. Anal. Chem. 2003, 75 (22), 6265-6274. 527 (29) Skotnicka-Pitak, J.; Garcia, E.M.; Pitak, M.; Aga, D.S. Identification of the 528 transformation products of 17α-ethinylestradiol and 17β-estradiol by mass spectrometry and 529 other instrumental techniques. Trends Anal. Chem. 2008, 27 (11), 1036-1052. 530 (30) Ke, J.; Zhuang, W.; Gin, K.Y-H.; Reinhard, M.; Hoon, L.T.; Tay, J-H. Characterization 531 of estrogen-degrading bacteria isolated from an artificial sandy aquifer with ultrafiltered 532 secondary effluent as the medium. Appl. Microbiol. Biotechnol. 2007, 75 (5), 1163-1171. 533 (31) Pauwels, B.; Wille, K.; Noppe, H.; De Brabander, H.; De Wiele, T.V.; Verstraete, W.; 534 Boon, N. 17a-ethinylestradiol cometabolism by bacteria degrading estrone, 17b-estradiol and 535 estriol. Biodegradation 2008, 19 (5), 683-693. 536 (32) Yu, C-P.; Roh, H.; Chu, K-H. 17β-estradiol-degrading bacteria isolated from activated 537 sludge. Environ. Sci. Technol. 2007, 41 (2), 486-492. 538 (33) Mao, L.; Huang, Q.; Lu, J.; Gao, S. Ligninase-mediated removal of natural and synthetic 539 estrogens from water: I. Reaction behaviors. Environ. Sci. Technol. 2009, 43 (2), 374-379. 540 23 (34) Mao, L.; Lu, J.; Habteselassie, M.; Luo, Q.; Gao, S.; Cabrera, M.; Huang, Q. Ligninase-541 mediated removal of natural and synthetic estrogens from water: II. Reactions of 17β-542 estradiol. Environ. Sci. Technol. 2010, 44 (7), 2599-2604. 543 (35) Mao, L.; Huang, Q.; Luo, Q.; Lu, J.; Yang, X.; Gao, X. Ligninase-mediated removal of 544 17β-estradiol from water in the presence of natural organic matter: Efficiency and pathways. 545 Chemosphere 2010, 80 (4), 469-473. 546 (36) Cajthaml, T.; Křesinová, Z.; Svobodová, K.; Sigler, K.; Řezanka, T. Microbial 547 transformation of synthetic estrogen 17α-ethinylestradiol. Environ. Pollut. 2009, 157 (12), 548 3325-3335. 549 (37) Chen, A.Y.; Lee, A.J.; Jiang, X-R.; Zhu, B.T. Chemical synthesis of six novel 17β-550 estradiol and estrone dimers and study of their formation catalyzed by human cytochrome 551 P450 isoforms. J. Med. Chem. 2007, 50 (22), 5372-5381. 552 (38) Pezella, A.; Lista, L.; Napolitano, A.; d’Ischia, M. Oxidative coupling of 17β-estradiol: 553 Inventory of oligomer products and configuration assignment of antropoisomeric C4-linked 554 biphenyl-type dimers and trimers. J. Org. Chem. 2004, 69 (17), 5652-5659. 555 556 557 24 Table 1. Sequence of experiments performed by operating continuously the EMR with a HRT of 4 h and an initial laccase activity of 100 U/L. Matrix Estrogens concentration Feed addition rate Experiment 1 Phosphate buffer solution (0.1 M, pH 7) 4 mg/L 1 mg/(L·h) Experiment 2 Phosphate buffer solution (0.1 M, pH 7) 100 µg/L 25 µg/(L·h) Experiment 3 Spiked real wastewater 100 µg/L 25 µg/(L·h) Experiment 4 Real wastewater Environmental concentrations: 0.29-1.52 ng/L 0.07-0.38 ng/(L·h) 25 Table 2. Characterization of the products detected by LC-APCI formed after 24 h of E1, E2 or EE2 laccase-catalyzed transformation, observed in the corresponding TIC after subtracting the signals of the blank and time 0 samples. Parent compound Retention time (min) Molecular ion Molecular weight Suggested product E1 8.1 269 268 not identified 13.7 539 538 E1 dimer E2 7.9 271 270 E1 9.7 525 542 E2 dimer I 10.9 525 542 E2 dimer II 12.2 525 542 E2 dimer III 13.0 795 812 E2 trimer I 13.6 795 812 E2 trimer II EE2 7.7 295 312 not identified 8.9 573 590 EE2 dimer I 9.6 573 590 EE2 dimer II 10.9 867 884 EE2 trimer I 11.8 867 884 EE2 trimer II 32 Table S1. Characteristics of filtered secondary effluent. Micropollutants ng/L Carbon and nitrogen content Concentration (mg/L) E1 1.52 inorganic carbon 5.6 E2 0.29 total organic carbon 5.6 EE2 0.74 total nitrogen 7.8 COD (mgO 2 /l) 33.80 inorganic nitrogen 3.0 pH 6.85 total Kjendahl nitrogen 4.8 Anions Concentration (mg/L) Cations Concentration (mg/L) NO2- 0.1 Na+ 38.2 Br- 0.0 NH4+ 0.0 NO3- 9.9 K+ 9.0 PO 4 3- 2.2 Mg2+ 2.9 SO 4 2- 21.3 Ca2+ 11.9 3. High performance liquid chromatography (HPLC) for the analyses of estrogens at high concentrations The analysis of the estrogens in the samples corresponding to the experiment at high initial concentration in buffer solution (Experiment 1) was carried out through HPLC in an HP-1090 system equipped with a diode array detector at 210 nm. Chromatographic separation was performed on a Lichrocart 250-4 column packed with Lichrosphere 100 RP-18 5 µm (Merck) and 100 µL of injection volume was used. The mobile phase consisted of a binary mixture of solvents A (acetonitrile) and B (50 mM phosphate buffer, pH 4.5) at a flow rate of 0.8 mL/min. The gradient method and running times were programmed as follows: initial conditions were 40% A for 1 min, then linearly programmed up to 80% until 20 min and held for 4 min, followed by a linear program at 40% for 5 min and held for 1 min. 33 4. Gas chromatography mass spectrometry (GC-MS) for analyses of estrogens at low concentrations Estrogens analysis corresponding to the experiments at low initial concentration in buffer solution or real wastewater (Experiments 2-3) were conducted by GC-MS using a Saturn 2100T (Varian) system with a CP Sil column (CP Sil 8 CB-MS low bleed (30 m x 0.25 mm x 0.25 µm). The analytical conditions are detailed in Table S2. Table S2. Equipment and conditions for the determination of estrogens by GC-MS. Chromatographic parameters Split-splitless injector Splitless time 2 min Injection temperature 280ºC Gas flow (He) 1 mL/min Injector (volume) 1 µL Solvent Ethyl acetate Temperature program Initial temperature 70ºC Initial time 2 min 1st ramp 25ºC/min Temperature 1 150ºC 2nd ramp 3ºC/min Temperature 2 200ºC 3rd ramp 8ºC/min Temperature 3 280ºC Time 3 5 min Mass Spectrometry Ionization mode Electronic impact Filament current 10 µA Ion ramp temperature 220ºC Transference line tt 280ºC Voltage 1700 – 1750 V Scan velocity 1s/scan Mass spectrum 50-550 m/z 34 Limits of quantification (LOQ) of the system were 10 µg/L in the case of E1 and E2 and 40 µg/L for EE2. Anyhow, the concentration of the samples allowed the quantification of the compounds at concentrations of 1.5 and 6 µg/L. 5. Liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry (LCAPCI-MS-MS) for analyses of estrogens at environmental concentrations The quantification of E1, E2 and EE2 present in the secondary effluent used as well as in the samples withdrawn during the experiment with non-spiked wastewater (Experiment 4) were performed by LCAPCI-MS-MS. The LC system used (Alginet 1100, Alginet Technologies) was equipped with Synergi 4u MAX-RP 80A column (4.60 mm × 250 mm, 4 μm, Phenomenex) for the analytes separation. The injection volume was 10 µL and the mobile phase consisted of a binary mixture of 0.1% formic acid (v/v) in water (A) and 100% methanol (B) at a flow rate of 0.7 mL/min. The gradient was as follows: initial conditions were 70% B, increased linearly up to 88% until 2 min, followed by a linear program to 94% until 15 min. Mass spectrometry was performed using an API 4000 triple quadrupole mass spectrometer (Applied Biosystems) and MS/MS was carried out in the multiple reaction mode (MRM) using APCI in positive mode. The values of the main parameters of the source are shown in Table S3. Table S3. Source-dependent parameters. Parameter Collision gas (psig) 6 Curtain gas (psig) 14 Ion source gas nebulizer (psig) 15 Nebulizer current (µA) 3 Temperature (ºC) 450 Entrance potential (V) 10 35 Retention times were as follows: 9.2 min (EE2), 9.6 min (E2) and 9.7 min (E1). For each compound, two characteristic fragmentations were optimized, the most abundant one being used for quantitation, while the second one with lower intensity was used as a qualifier, as shown in Table S4. Table S4. MRM conditions used for the analysis of the estrogens. Compound MRM transition  product ion E1 271.1  133.2, 271.1  159.2 E2 255.0  159.1, 255.0  133.1 EE2 279.2  133.1, 279.2  159.2 LOQs were 0.5 µg/L; however, the concentration of the samples (described in Materials and methods section) provided a reduction of the limits of quantification to 0.02 ng/L for the secondary effluent samples and 0.01 ng/L for the samples withdrawn from the EMR effluent during the Experiment 4. In order to corroborate the removal results of E1, E2 and EE2, E2-d4 was used as internal standard throughout the analytical procedure. The deuterated compound was added to the samples before the SPE (5 ng, which meant concentrations prior to SPE of 2.5 and 1 ng/L in the EMR influent and effluent samples, and 66.66 µg/L after concentration of the samples for subsequent LC/MS/MS analysis). The quantification of the estrogenic compounds was carried out using calibration curves built by plotting the ratio analyte peak area/E2-d4 peak area versus the analyte concentration; calibration standards contained increasing amounts of the analytes in the range 0.5-70 µg/L, and a fixed concentration of the surrogate of 66.66 µg/L. The surrogate presented the following transitions: 259.2  161.1 and 259.2  135.0, and retention time 9.5 min. 36 6. Results obtained after the performance of the EMR for the treatment of synthetic water (buffered solution) at high and low estrogens initial concentrations 0 10 20 30 40 50 60 70 80 90 100 110 0.0 0.2 0.4 0.6 0.8 1.0 1.2 0 20 40 60 80 100 Activity (U/L) Degradation rate (mg/(L·h)) Outlet rate (mg/(L·h)) time (h) Average estrogens outlet rate (mg/(L·h)) - Control E1 degradation rate (mg/(L·h)) E2 degradation rate (mg/(L·h)) EE2 degradation rate (mg/(L·h)) Laccase activity (U/L) Figure S2. Time course of E1, E2 and EE2 degradation rates and laccase activity during the operation of the EMR for the treatment of synthetic waster containing 4 mg/L of each estrogen (feed addition rate 1 mg/(L·h)) by 100 U/L of initial laccase activity (Experiment 1), and average of the estrogens outlet rate during the corresponding control assay lacking laccase. 0 10 20 30 40 50 60 70 80 90 100 110 0 3 6 9 12 15 18 21 24 27 0 20 40 60 80 100 Activity (U/L) Degradation rate (µg/(L·h)) Outlet rate (µg/(L·h)) time (h) Average estrogens outlet rate (µg/(L·h)) - Control E1 degradation rate (µg/(L·h)) E2 degradation rate (µg/(L·h)) EE2 degradation rate (µg/(L·h)) Laccase activity (U/L) Figure S3. Time course of E1, E2 and EE2 degradation rates and laccase activity during the operation of the EMR for the treatment of synthetic water containing 100 µg/L of each estrogen (feed addition rate 25 µg/(L·h)) by 100 U/L of initial laccase activity (Experiment 2), and average of the estrogens outlet rate during the corresponding control assay lacking laccase. 37 7. Total ion chromatograms (TIC) and mass spectra resulted from the study of identification of laccasecatalyzed transformation products of E1, E2 and EE2 by LC-APCI analysis Intensity (cps)Intensity (cps) m/z Time (min) 13.7 8.1 (A) (B) Figure S4. TIC of the sample after 24 h of laccase-catalyzed transformation of E1 (A) and mass spectrum of E1 dimer (B) obtained by LC-APCI positive in full scan mode. 38 Intensity (cps)Intensity (cps)Intensity (cps) Time (min) m/z m/z 7.9 9.7 10.9 12.2 13.0 13.6 (A) (B) (C) Figure S5. TIC of the sample after 24 h of laccase-catalyzed transformation of E2 (A) and mass spectra of E2 dimer I (B) and E2 trimer I (C) obtained by LC-APCI positive in full scan mode. 39 Intensity (cps)Intensity (cps)Intensity (cps) Time (min) m/z m/z 7.7 (A) (B) (C) 8.9 9.6 10.9 11.8 Figure S6. TIC of the sample after 24 h of laccase-catalyzed transformation of EE2 (A) and mass spectra of EE2 dimer I (B) and EE2 trimer I (C) obtained by LC-APCI positive in full scan mode. 40 8. Determination of accurate masses of biotransformation products by liquid chromatography electrospray time-of-flight mass spectrometry (LC-ESI-TOF) Samples were analyzed by LC-ESI-TOF to obtain information concerning accurate masses. For this purpose, a LC system (Alginet 1100) equipped with a Zorbax Eclipse XDB (C18 3 mm x 250 mm, 5 µm) (Alginet) analytical column was used. A binary solvent comprised acetonitrile (ACN) was used as the mobile phase. Flow rate was set at 0.6 mL/min and the gradient was programmed as following: 0 minutes, 40% ACN; 10 minutes, 60% ACN; 40 minutes, 80% ACN; 43 minutes, 100% ACN; 44 minutes, 100% ACN; and the injection volume was 15 µL. This LC system was connected to a Microtof Bruker Daltonics mass spectrometer with an ESI source operated at negative mode and under the following conditions: capillary, 4.5 kV; drying gas, 8 L/min; gas temperature, 200ºC. The results obtained after the analyses of the samples from the batch experiments are shown in Table S5. Table S5. Accurate masses of the transformation products (deprotonated compounds) detected by LC-ESI- TOF in the samples from the batch assays. Parent compound Suggested product Elemental composition Theoretical mass Experimental mass mDa error (ppm) E1 Dimer C36H41O4 537.3010 537.3037 -2.6 -5.0 537.3038 -2.7 -5.2 E2 Dimer C36H45O4 541.3323 541.3320 0.3 0.6 541.3315 0.8 1.5 541.3334 -1.1 -2.0 541.3325 0.9 -0.4 Trimer C54H67O6 811.4943 811.4954 -1.1 -1.4 811.4942 0.1 0.1 811.4943 0.0 0.0 E1 C18H21O2 269.1547 269.1536 -1.6 4.1 EE2 Dimer C40H45O4 589.3323 589.3312 1.2 1.9 589.3328 -0.4 -0.8 589.3330 -0.6 -1.2 589.3323 0.0 0.0 Trimer C60H67O6 883.4943 883.4949 -0.5 -0.7 883.4963 -2.2 -2.3 883.4959 -1.6 -1.8 883.4954 -1.1 -1.3