scieee AI-readable full text Open interactive document viewer

Lidocaine-Loaded Solid Lipid Microparticles (SLMPs) Produced from Gas-Saturated Solutions for Wound Applications

López Iglesias, Clara; Quílez, Cristina; Barros, Joana; Velasco, Diego; Álvarez Lorenzo, Carmen; Jorcano, José L.; Monteiro, Fernando J.; García González, Carlos A.

Abstract

The delivery of bioactive agents using active wound dressings for the management of pain and infections offers improved performances in the treatment of wound complications. In this work, solid lipid microparticles (SLMPs) loaded with lidocaine hydrochloride (LID) were processed and the formulation was evaluated regarding its ability to deliver the drug at the wound site and through the skin barrier. The SLMPs of glyceryl monostearate (GMS) were prepared with different LID contents (0, 1, 2, 4, and 10 wt.%) using the solvent-free and one-step PGSS (Particles from Gas-Saturated Solutions) technique. PGSS exploits the use of supercritical CO2 (scCO2) as a plasticizer for lipids and as pressurizing agent for the atomization of particles. The SLMPs were characterized in terms of shape, size, and morphology (SEM), physicochemical properties (ATR-IR, XRD), and drug content and release behavior. An in vitro test for the evaluation of the influence of the wound environment on the LID release rate from SLMPs was studied using different bioengineered human skin substitutes obtained by 3D-bioprinting. Finally, the antimicrobial activity of the SLMPs was evaluated against three relevant bacteria in wound infections (Escherichia coli, Staphylococcus aureus, and Pseudomonas aeruginosa). SLMPs processed with 10 wt.% of LID showed a remarkable performance to provide effective doses for pain relief and preventive infection effects

Full text

pharmaceutics Article Lidocaine-Loaded Solid Lipid Microparticles (SLMPs) Produced from Gas-Saturated Solutions for Wound Applications Clara López-Iglesias 1, Cristina Quílez 2, Joana Barros 3, Diego Velasco 2, Carmen Alvarez-Lorenzo 1, JoséL. Jorcano 2, Fernando J. Monteiro 3and Carlos A. García-González 1,* 1Department of Pharmacology, Pharmacy and Pharmaceutical Technology, I+D Farma group (GI-1645), Faculty of Pharmacy, Agrupación Estratégica de Materiales (AeMAT) and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain; [email protected] (C.L.-I.); carmen.alvarez.lor[email protected] (C.A.-L.) 2Department of Bioengineering and Aerospace Engineering, Universidad Carlos III de Madrid (UC3M), 28911 Leganés (Madrid), Spain; [email protected] (C.Q.); [email protected] (D.V.); [email protected] (J.L.J.) 3Instituto de Investigação e Inovação em Saúde da Universidade do Porto (i3S), Instituto de Engenharia Biomédica (INEB), Faculdade de Engenharia (FEUP), Universidade do Porto, 4200-135 Porto, Portugal; [email protected] (J.B.); [email protected] (F.J.M.) *Correspondence: [email protected]; Tel.: +34-881-814-882 Received: 6 August 2020; Accepted: 9 September 2020; Published: 12 September 2020   Abstract: The delivery of bioactive agents using active wound dressings for the management of pain and infections offers improved performances in the treatment of wound complications. In this work, solid lipid microparticles (SLMPs) loaded with lidocaine hydrochloride (LID) were processed and the formulation was evaluated regarding its ability to deliver the drug at the wound site and through the skin barrier. The SLMPs of glyceryl monostearate (GMS) were prepared with different LID contents (0, 1, 2, 4, and 10 wt.%) using the solvent-free and one-step PGSS (Particles from Gas-Saturated Solutions) technique. PGSS exploits the use of supercritical CO 2 (scCO 2 ) as a plasticizer for lipids and as pressurizing agent for the atomization of particles. The SLMPs were characterized in terms of shape, size, and morphology (SEM), physicochemical properties (ATR-IR, XRD), and drug content and release behavior. An in vitro test for the evaluation of the influence of the wound environment on the LID release rate from SLMPs was studied using different bioengineered human skin substitutes obtained by 3D-bioprinting. Finally, the antimicrobial activity of the SLMPs was evaluated against three relevant bacteria in wound infections (Escherichia coli,Staphylococcus aureus, and Pseudomonas aeruginosa). SLMPs processed with 10 wt.% of LID showed a remarkable performance to provide effective doses for pain relief and preventive infection effects. Keywords: SLMPs; drug delivery; lidocaine HCl; 3D-bioprinting; PGSS technique; wound healing; pain 1. Introduction Pain is one of the most debilitating symptoms of patients suffering from chronic and post-surgical wounds, especially during wound debridement and dressing exchange [ 1 ]. As an example, ca. 80% of patients suffering from venous leg ulcers report acute or chronic wound pain, which causes discomfort, stress, anxiety and, overall, poor quality of life [ 2 – 5 ]. Local anesthetics, and lidocaine hydrochloride (LID) in particular, have been used for decades to reduce wound pain (e.g., in post-operative Pharmaceutics 2020,12, 870; doi:10.3390/pharmaceutics12090870 www.mdpi.com/journal/pharmaceutics Pharmaceutics 2020,12, 870 2 of 16 analgesia) without hampering the physiological scarring process [ 6 , 7 ]. The mechanism of action of LID is the specific interaction and blockage of sodium channels of the sensorial neurons [ 8 ]. Through this LID–neuron interaction, when the nerve impulse arrives to the cell and the cell membrane is depolarized, sodium cations are unable to enter the neuron and the nerve impulse transmission is stopped. Furthermore, LID also has certain antimicrobial activity against common bacteria in nosocomial and surgical wound infections (e.g., Enterococcus faecalis,Escherichia coli, Staphylococcus aureus, and Pseudomonas aeruginosa), so its local infusion may also prevent bacterial colonization in post-operative wounds [9,10]. Particulate systems like micro- and nanoparticles are of increasing interest for drug delivery to the wound site [ 11 , 12 ]. The use of micron- and nano-sized systems based on organic and inorganic materials to deliver bioactive agents improves their efficacy and safety, and increases their physicochemical stability by protecting them from the environment (e.g., enzymatic degradation) [ 13 – 15 ]. Microparticles are often preferred for local drug delivery since they remain in the application site while providing a sustained drug release [ 15 ]. Lipids are regarded as advantageous components of particulate matrices for wound care, since they can mimic the natural components of skin and modulate the drug release [ 16 – 20 ]. Namely, solid lipid microparticles (SLMPs) usually present higher physicochemical stability and are easier to sterilize and to scale-up than other lipid-based drug carriers like liposomes [ 21 ]. SLMPs have not been extensively studied for dermal and wound delivery, but have shown as potential candidates for topical and transdermal delivery of several drugs like econazole nitrate, testosterone, and tetracycline [22,23]. SLMPs processing usually requires the use of organic solvents and emulsifying agents, but novel processing strategies are arising to improve environmental and economic aspects. Supercritical CO 2 (scCO 2 ) has emerged as a processing tool for the development of new, green, and inexpensive techniques that require mild conditions and avoid/mitigate organic solvents [ 14 , 24 – 26 ]. Namely, the PGSS (Particles from Gas-Saturated Solutions) technique is based on the dissolution of scCO 2 in a molten substance, followed by a rapid expansion through a nozzle of the molten substance that causes solidification and precipitation of solid microparticles [ 27 – 30 ]. Unlike other compressed fluids, scCO 2 can interact with the processed substances at a molecular level decreasing their melting temperature, which may be advantageous for the scale-up of the process in terms of energy and cost optimization [ 28 , 31 ]. The processing of SLMPs using the PGSS technique avoids the use of solvents or washing steps. High loading efficiencies of bioactive agents (insulin, recombinant human growth hormone, ibuprofen, ketoprofen) are commonly obtained using this technique [ 32 – 36 ]. The advantageous features of PGSS technique can be herein exploited for the processing of SLMPs loaded with LID. These SLMPs can lead to a more prolonged release of LID and a longer duration of action than commercial LID-containing ointments, gels, and solutions. LID-loaded particles may thus adapt to the demands of the pharmacological action site (wound) where the damaged tissue accelerates drug permeation due to the absence of epidermis and the modified LID release also reduces the drug side effects of systemic absorption. Drug permeability and toxicity in vitro test alternatives to the use of human or animal native skin are pursued to evaluate the performance of topical formulations, since these in vivo practices are constrained by economic, ethical, and practical reasons or even by regulation in the case of cosmetics [ 37 , 38 ]. Following the 3Rs principles and with the rise of the biomedical engineering discipline, several in vitro artificial skin models with attractive versatility and reproducibility are being commercialized or under development to reflect the three-dimensional environment of human native skin and the in vivo drug release conditions through the skin barrier [ 39 ]. 3D-bioprinting has emerged as an ideal technology to design more complex artificial skin models under automatized and standardized protocols able to mimic the native skin in a more reproducible manner [ 40 ]. The versatility of 3D-bioprinting has high translational and clinical relevance, since this technology can be exploited to produce not only full-thickness healthy skin, but also damaged skin under different pathological situations like acute and chronic wounds [41]. Pharmaceutics 2020,12, 870 3 of 16 In this work, the PGSS technique was implemented for the first time to produce SLMPs for specific wound delivery applications in pain and infection treatment. The SLMPs consisted on a matrix of glyceryl monostearate (GMS) loaded with LID at different contents (0, 1, 2, 4, and 10 wt.%) in an attempt to get formulations in the typical LID topical dosage range (0.5–5 wt.%) [ 42 , 43 ]. To the best of our knowledge, it is the first time that SLMPs loaded with LID were processed by the PGSS technique. Obtained SLMPs were characterized in terms of physicochemical properties and drug content. Drug release behavior of LID from the SLMPs was evaluated using Franz cells and bioengineered skin substitutes with and without epidermis to evaluate the transport and release of LID through the intact skin and open wound skin tissues. Finally, the antimicrobial activity of LID released from the SLMPs against susceptible bacterial strains commonly present in infected wounds (E. coli,S. aureus, and P. aeruginosa) was assessed. 2. Materials and Methods 2.1. Materials Kolliwax ® GMS II (glycerolmonostearate 40-55 type II, powder) was supplied by BASF (Ludwigshafen am Rhein, Germany). Lidocaine HCl monohidrate ( ≥ 99% purity) was purchased from Sigma-Aldrich (Saint Louis, MO, USA). CO 2 (99.8% purity) was supplied by Praxair (Madrid, Spain). Glacial acetic acid (purity >99.0%) and acetonitrile (HPLC grade, purity >99.9%) were purchased from Scharlau (Barcelona, Spain). NaOH (98.0% purity) was obtained from Panreac (Barcelona, Spain). Water was purified using reverse osmosis (resistivity >18 M Ω· cm, Milli-Q, Millipore ® , Madrid, Spain). Mueller-Hinton agar and broth were supplied by Merck Millipore (Darmstadt, Germany) and were used to perform the antimicrobial assays. Human primary fibroblasts (hFBs) and human primary keratinocytes (hKCs) obtained from skin biopsies of healthy donors were obtained from the collections of biological samples of human origin, which are registered in the Registro Nacional de Biobancos para Investigaci ó n Biom é dica del Instituto de Salud Carlos III with reference C.0002961. This collection is located in the Centro Comunitario de Sangre y Tejidos (CCST, Oviedo, Spain) and in the CIEMAT. Fresh frozen human plasma was provided by a local blood bank (Banco de Sangre del Centro Comunitario de Transfusi ó n del Principado de Asturias, Oviedo, Spain), and was obtained following the standards of the American Association of Blood Banks [44]. 2.2. SLMPs Production by the PGSS Technique Mixtures (6 g) of GMS manually mixed with a LID content of 0, 1, 2, 4, and 10 wt.% were loaded into a 300-mL high-pressure saturator (Eurotechnica GmbH, Bargteheide, Germany). After heating the saturator to 67 ◦ C, CO 2 entered the equipment at a constant flow of 7 g/min until a pressure of 170 bar was reached. After 1 h of contact of the compressed CO 2 with the molten lipid and drug under agitation at 400 rpm, the system was depressurized by the opening of a valve placed at the bottom of the saturator. The mixture was thus sprayed through a nozzle of 1 mm of diameter, and the fast depressurization caused the precipitation of the lipid-based formulation into solid microparticles inside a precipitator vessel of 2.7 L. SLMPs were then collected and kept in 50-mL Falcon tubes for further use. The SLMPs were denoted as GMS-LIDx,xbeing the theoretical content of LID expressed as wt.%. 2.3. Analysis of the Morphology, Size, and Surface of the Particles Images of the GMS particles processed by the PGSS technique were obtained by scanning electron microscopy (SEM, EVO LS 15, Zeiss, Oberkochen, Germany) to evaluate the morphology, size, homogeneity, and surface of the particles. Prior to imaging, SLMPs were sputtered-coated (Q150T S/E/ES, Quorum Technologies, Lewes, UK) with a layer of 10 nm of iridium to improve the contrast. Particle sizes were measured by image analysis using ImageJ v1.49 software (National Institutes of Health, Bethesda, MD, USA). Pharmaceutics 2020,12, 870 4 of 16 2.4. Physicochemical Characterization Raw GMS powder, raw LID powder, GMS-LID0 and GMS-LID4 particles were analyzed by Attenuated Total Reflectance/Fourier-Transform Infrared Spectroscopy (ATR/FT-IR). A Gladi-ATR accessory equipped with a diamond crystal (Pike, Madison, WI, USA) was used. Spectra were collected in the mid-IR spectrum range (400–4000 cm −1 ) using 32 scans at a resolution of 2 cm −1 . Crystallinity of the raw materials and GMS-LID0 and GMS-LID4 particles obtained by the PGSS technique were studied by X-ray diffraction (XRD, PW-1710, Philips, Eindhoven, The Netherlands) in the 2–50 ◦ 2 θ -range using a 0.02 ◦ step and CuK α1 radiation. The raw materials, GMS-LID0 and GMS-LID4 were also analyzed using differential scanning calorimetry (DSC, DSC-Q100, TA Instruments; New Castle, DE, USA). Samples were weighted in an aluminum pan, cooled down from room temperature to 0 ◦ C, and then heated up to 150 ◦C at a rate of 5 ◦C/min. 2.5. Determination of LID Encapsulation Efficiency The encapsulation efficiency (EE) was evaluated by dispersing 26 mg of GMS-LID1, GMS-LID2, GMS-LID4, andGMS-LID10 particles in10mLof PBSpH7.4underagitation(700rpm). The suspensions were heated at 70 ◦ C for 4 h until microparticles were molten and the entrapped drug was fully dissolved. Afterwards, the suspensions were centrifuged and cooled down (4000 rpm, 20 ◦ C) and 1 mL of the supernatant was extracted and filtered with syringe filters (hydrophilic PTFE, 0.22 µ m, Scharlau, Barcelona, Spain) for HPLC measurements. LID concentration was measured by HPLC (JASCO Spain, Madrid, Spain) using a C18 column (Symmetry ® , 5 µ m, 3.9 × 150 mm, Waters, Milford, MA, USA) with isocratic elution [ 45 ]. The mobile phase consisted of acetonitrile:acetic acid 5% (pH 3.4 adjusted with 1 M NaOH solution) 15:85 (v/v). Flow was kept at 1 mL/min and temperature at 30 ◦ C. LID had a retention time of 4.5 min, and the absorbance was measured at the wavelength of 262 nm. The calibration curve was carried out in the 1–100 µg/mL range (R2=0.9995). The encapsulation efficiency (EE) was calculated following the equation (Equation (1)): EE =wP wT ×100 (1) where w P is the amount of LID contained in the SLMPs measured by HPLC (in mg LID per mg of SLMPs) and w T is the initial amount of LID added for PGSS processing (in mg LID per mg of GMS-LID mixture). 2.6. LID Release Tests from SLMPs The release of LID from raw LID, GMS-LID1, GMS-LID2, GMS-LID4, and GMS-LID10 particles was performed in Franz diffusion cells consisting of a donor and a receptor compartment separated by a 0.45 µ m cellulose nitrate membrane filter (Whatman, Little Chalfont, UK). Franz cells were kept in an orbital shaker (VWR ® Incubating Mini Shaker, VWR, Chester, PA, USA) at 37 ◦ C under agitation at 100 rpm. The volume of the receptor compartment was 6 mL and the surface available for diffusion was ca. 0.8 cm 2 . The receptor compartment was filled with PBS pH 7.4 medium, and 25 mg of particles were placed in the donor compartment with 0.5 mL of PBS medium. Then, 1 mL-aliquots were taken every hour for the first 8 h and then after 24 h, and the same volume was replaced with fresh PBS solution. Samples were filtered with syringe filters (hydrophilic PTFE, 0.22 µ m, Scharlau, Barcelona, Spain) and measured by HPLC (see Section 2.5). The release of LID from SLMPs was compared to the dissolution of 3 mg of pure LID, carried out using the same experimental set-up. LID release profiles of the drug were fitted to the first-order (Equation (2)) and the first-order with lag time (Equation (3)) release kinetics models: % LID released =100 ×(1−e−k1×t)(2) Pharmaceutics 2020,12, 870 5 of 16 % LID released =100 ×(1−e−k2×(t−tlag))(3) where k1and k2are the kinetic coefficients, tis the elapsed release time, and tlag is the lag time. 2.7. Preparation of Bioprinted Human Skin Equivalents Bioprinted human skin substitutes were generated following a previously developed method [ 46 ]. Briefly, two cellular layers were printed: a dermal layer, formed by a plasma-derived fibrin matrix populated with hBFs, and an epidermal layer formed by hKCs seeded on top. Cell cultures were printed on polyethylene terephthalate (PET) cellular inserts (Falcon 353102, 4.2 cm 2 area, 1 µ m pore diameter; Thermo Fischer Scientific, Waltham, MA, USA) in a 6-well culture plate (4.15 cm 2 , Corning Costar Corp., Cambridge, MA, USA) and were allowed to differentiate at the air–liquid interface for 17 days at 37 ◦ C in a CO 2 incubator in hKCs medium containing 0.5% FBS and 50 µ g of ascorbic acid as differentiating medium (Figure S1A). The medium was changed every three days. 2.8. LID Release Tests through Bioprinted Human Skin Equivalents Firstly, the diffusion of LID dissolved in PBS from pure LID powder and the GMS-LID4 microparticles through the intact bioengineered skin equivalent, i.e., with epidermal and dermal layers were compared. The bioengineered skin equivalents were collected (Figure S1B) and cut with a scalpel in circles of 2 cm of diameter, and used as membranes in 6-mL Franz diffusion cells (Figure 1A). Release tests and LID measurements by HPLC were carried out in four replicates and using the same protocols as in Section 2.5. Pharmaceutics 2020, 12, x 5 of 16 2.7. Preparation of Bioprinted Human Skin Equivalents Bioprinted human skin substitutes were generated following a previously developed method [46]. Briefly, two cellular layers were printed: a dermal layer, formed by a plasma-derived fibrin matrix populated with hBFs, and an epidermal layer formed by hKCs seeded on top. Cell cultures were printed on polyethylene terephthalate (PET) cellular inserts (Falcon 353102, 4.2 cm 2 area, 1 μm pore diameter; Thermo Fischer Scientific, Waltham, MA, USA) in a 6-well culture plate (4.15 cm 2 , Corning Costar Corp., Cambridge, MA, USA) and were allowed to differentiate at the air–liquid interface for 17 days at 37 °C in a CO 2 incubator in hKCs medium containing 0.5% FBS and 50 μg of ascorbic acid as differentiating medium (Figure S1A). The medium was changed every three days. 2.8. LID Release Tests through Bioprinted Human Skin Equivalents Firstly, the diffusion of LID dissolved in PBS from pure LID powder and the GMS-LID4 microparticles through the intact bioengineered skin equivalent, i.e., with epidermal and dermal layers were compared. The bioengineered skin equivalents were collected (Figure S1B) and cut with a scalpel in circles of 2 cm of diameter, and used as membranes in 6-mL Franz diffusion cells (Figure 1A). Release tests and LID measurements by HPLC were carried out in four replicates and using the same protocols as in Section 2.5. A second part of the LID release tests was carried out to compare the diffusion of LID from SLMPs through intact bioengineered skin equivalents (Figure 1(B.1)) and the same skin equivalents without epidermis (only dermis, Figure 1(B.2)) to mimic an open skin wound. Using the bioengineered skin equivalents in the cellular insert, the epidermis was removed with the help of precision forceps. The experiment was carried out in triplicate and directly in the cellular inserts adapting a protocol from the literature [47]. GMS-LID4 particles were added to each insert along with 0.5 mL of PBS to facilitate their humectation. The 6-well culture plate was filled with 10 mL of PBS pH 7.4 as the receptor medium. The 1-mL aliquots were taken at the same selected times, filtered with syringe filters (hydrophilic PTFE, 0.22 μm pore diameter; Scharlau, Barcelona, Spain), and measured by HPLC (see Section 2.5). The extracted volume was replaced with equal volumes of fresh PBS medium. Figure 1. Full thickness skin substitute consisting of epidermal (1) and dermal (2) tissues was cultured on cellular inserts (3) using human primary keratinocytes (hKCs) culture medium (4). For permeation tests, the base of the cellular insert with full thickness skin was placed as separator membrane in Franz cells (A), usingraw lidocaine hydrochloride (LID) or drug-loaded GMS-LID4 particles (5) in the donor compartment. The release medium was PBS pH 7.4 (6). Another part of the experiment tested the permeation of LID from GMS-LID4 particles directly in the cellular inserts, using (B.1) either full thickness skin substitute (7) containing the keratinocyte layer, (B.2) or dermal tissue (8) without epidermis as membrane. Figure 1. Full thickness skin substitute consisting of epidermal (1) and dermal (2) tissues was cultured on cellular inserts (3) using human primary keratinocytes (hKCs) culture medium (4). For permeation tests, the base of the cellular insert with full thickness skin was placed as separator membrane in Franz cells ( A ), usingraw lidocaine hydrochloride (LID) or drug-loaded GMS-LID4 particles (5) in the donor compartment. The release medium was PBS pH 7.4 (6). Another part of the experiment tested the permeation of LID from GMS-LID4 particles directly in the cellular inserts, using ( B.1 ) either full thickness skin substitute (7) containing the keratinocyte layer, ( B.2 ) or dermal tissue (8) without epidermis as membrane. A second part of the LID release tests was carried out to compare the diffusion of LID from SLMPs through intact bioengineered skin equivalents (Figure 1(B.1)) and the same skin equivalents without epidermis (only dermis, Figure 1(B.2)) to mimic an open skin wound. Using the bioengineered skin equivalents in the cellular insert, the epidermis was removed with the help of precision forceps. The experiment was carried out in triplicate and directly in the cellular inserts adapting a protocol from the literature [ 47 ]. GMS-LID4 particles were added to each insert along with 0.5 mL of PBS to facilitate their humectation. The 6-well culture plate was filled with 10 mL of PBS pH 7.4 as the Pharmaceutics 2020,12, 870 6 of 16 receptor medium. The 1-mL aliquots were taken at the same selected times, filtered with syringe filters (hydrophilic PTFE, 0.22 µ m pore diameter; Scharlau, Barcelona, Spain), and measured by HPLC (see Section 2.5). The extracted volume was replaced with equal volumes of fresh PBS medium. Histological analysis of the bioengineered skin equivalents was performed before and after (24 h) the drug release experiments to assess their integrity and whether the particles penetrated them. Skin samples were fixed in 3.7% buffered formaldehyde for 24 h and embedded in paraffin. Then, 5- µ m cross-sections were dewaxed, rehydrated, and stained with hematoxylin-eosin (H&E). 2.9. Antimicrobial Tests The antimicrobial activity of LID was assessed against susceptible bacterial strains commonly present in infected wounds: E. coli 25922, S. aureus 33591, and P. aeruginosa PA01. Susceptibility tests to LID were performed by determination of the minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of LID powder, according to the CLSI standards broth microdilution procedure. Furthermore, the antimicrobial activity of LID released from 40 mg of GMS-LID10 particles in 5 mL of PBS medium after 6 h was evaluated by quantifying the cultivable bacteria. 2.9.1. Minimum Inhibitory Concentration Bacteria were grown overnight at 37 ◦ C in Mueller-Hinton Broth (MHB) at 150 rpm. After incubation, a bacterial suspension was adjusted to ca. 10 6 colony forming units (CFU/mL). Subsequently, 100 µ L of bacterial suspension and 100 µ L of LID at different concentrations (39,400, 19,700, 9850, 4925, 2463, and 1231 µ g/mL) were placed in 96-well microplates and incubated for 24 h at 37 ◦ C and 150 rpm. Bacterial growth (turbidity) was evaluated measuring absorbance at 640 nm in a microplate reader. All tests were performed in quintuplicate with two repeats. MICs were expressed in terms of µ g/mL [ 48 ]. Two controls were used to perform the antimicrobial tests: a positive control representing the bacterial growth without LID (0 µ g/mL) and a negative control representing the absorbance of medium without bacteria. 2.9.2. Minimum Bactericidal Concentration Bacteria were grown overnight in MHB at 37 ◦ C and 150 rpm. After incubation, a bacterial suspension was adjusted to ca. 10 6 colony forming units (CFU/mL). Then, 100 µ L of bacterial suspension and 100 µ L of LID (at the same concentrations as for the MIC determination) were placed in 96-well microplates and incubated for 24 h at 37 ◦ C and 150 rpm. Subsequently, cultivable bacteria were quantified by colony counting in Mueller-Hinton Agar (MHA). All experiments were performed in quintuplicate with two repeats. MBCs were expressed in terms of µ g/mL [ 48 ]. Two controls were used to perform the antimicrobial tests: a positive control representing the bacterial growth without LID (0 µg/mL) and a negative control representing the initial bacterial concentration. 2.9.3. Antimicrobial Activity of LID Released from GMS Bacteria were grown overnight in MHB at 37 ◦ C and 150 rpm and a bacterial suspension of ca. 10 7 cells/mL. GMS-LID10 particles (40 mg) were dispersed in 5 mL of PBS pH 7.4. Then, 180 µ L of PBS with LID released from GMS-LID10 particles and 20 µ L of bacterial suspension were placed (five for each condition) in 96-well plates. After 24 h incubation at 37 ◦ C and 150 rpm, the cultivable bacteria were quantified by the colony-forming units (CFUs) method. Bacterial density (in log 10 CFUs/mL) was plotted according to each condition. Bacterial growth without LID was used as control. All experiments were performed in quintuplicate with two repeats. 2.10. Statistical Analysis Results were reported as mean ± standard deviation. Statistical analysis of the antimicrobial tests was performed using one-way analysis of variance (ANOVA) test followed by post-hoc Tukey Pharmaceutics 2020,12, 870 7 of 16 HSD multiple comparison test (IBM®SPSS®Statistics v.22.0, Armonk, NY, USA), which was used to determine the significant difference (p). 3. Results and Discussion 3.1. Morphological and Physicochemical Properties of the SLMPs Obtained GMS particles were fine, white, and free-flowing powder. The conditions of pressure and temperature for the processing of GMS particles containing LID were selected above the melting point of GMS so they would provide good process ability. Thus, the SEM images showed an open and porous structure, caused by the escape of CO 2 from the molten lipid and sudden solidification upon depressurization (Figure 2). The shape of the particles was non-spherical and particle diameter was in the 20–120 µ m range with a mean of 114 µ m, a standard deviation of 39 µ m, and a PDI of 0.12. The non-sphericity of lipid particles using the PGSS technique is also observed using other SLMPs processing technologies like spray drying and this morphology can influence the drug release behavior due to shorter drug diffusion pathways [ 49 , 50 ]. The processing of GMS together with LID did not influence the overall appearance of the particles. Pharmaceutics 2020, 12, x 7 of 16 3. Results and Discussion 3.1. Morphological and Physicochemical Properties of the SLMPs Obtained GMS particles were fine, white, and free-flowing powder. The conditions of pressure and temperature for the processing of GMS particles containing LID were selected above the melting point of GMS so they would provide good process ability. Thus, the SEM images showed an open and porous structure, caused by the escape of CO 2 from the molten lipid and sudden solidification upon depressurization (Figure 2). The shape of the particles was non-spherical and particle diameter was in the 20–120 μm range with a mean of 114 μm, a standard deviation of 39 μm, and a PDI of 0.12. The non-sphericity of lipid particles using the PGSS technique is also observed using other SLMPs processing technologies like spray drying and this morphology can influence the drug release behavior due to shorter drug diffusion pathways [49,50]. The processing of GMS together with LID did not influence the overall appearance of the particles. Figure 2. Scanning electron microscopy (SEM) images of (A,B) GMS-LID0 and (C,D) GMS-LID4 particles. The processing of GMS with LID did not influence the overall appearance and shape of the particles. ATR/FT-IR spectroscopic studies confirmed the presence of LID in the GMS-based particles (Figure 3A). The spectrum of GMS-LID4 particles showed a small band at the wavelength of 1542 cm −1 , corresponding to the characteristic band of C=O carbonyl group stretching mode of LID [51]. Spectra of pure GMS powder and GMS processed by the PGSS technique were practically identical, proving that the processing with scCO 2 did not alter the chemical structure of the GMS. The XRD analysis of the GMS-LID4 powder (Figure 3B) did not show the characteristic sharp peaks of crystalline LID, suggesting the change of the drug from the crystalline to the amorphous state upon processing with the PGSS technique. The absence of crystalline LID was also confirmed by the DSC analysis (Figure 4). No peaks corresponding to crystalline LID were observed in the thermogram of the GMS-LID4 particles. The main thermal events obtained from the DSC thermograms after peak integration are summarized in Table 1. Table 1. Thermal properties of raw materials and GMS particles processed without (GMS-LID0) and with LID (GMS-LID4). Thermal Event LID GMS GMS-LID0 GMS-LID4 T m (°C) 78.12 62.28 62.46 60.56 ΔH m (J/g) 187.0 186.8 179.1 170.9 Figure 2. Scanning electron microscopy (SEM) images of ( A , B ) GMS-LID0 and ( C , D ) GMS-LID4 particles. The processing of GMS with LID did not influence the overall appearance and shape of the particles. ATR/FT-IR spectroscopic studies confirmed the presence of LID in the GMS-based particles (Figure 3A). The spectrum of GMS-LID4 particles showed a small band at the wavelength of 1542 cm −1 , corresponding to the characteristic band of C=O carbonyl group stretching mode of LID [ 51 ]. Spectra of pure GMS powder and GMS processed by the PGSS technique were practically identical, proving that the processing with scCO 2 did not alter the chemical structure of the GMS. The XRD analysis of the GMS-LID4 powder (Figure 3B) did not show the characteristic sharp peaks of crystalline LID, suggesting the change of the drug from the crystalline to the amorphous state upon processing with the PGSS technique. The absence of crystalline LID was also confirmed by the DSC analysis (Figure 4). No peaks corresponding to crystalline LID were observed in the thermogram of the GMS-LID4 particles. The main thermal events obtained from the DSC thermograms after peak integration are summarized in Table 1. Pharmaceutics 2020,12, 870 8 of 16 Pharmaceutics 2020, 12, x 8 of 16 Figure 3. (A) Attenuated Total Reflectance/Fourier-Transform Infrared Spectroscopy (ATR/FT-IR) spectra and (B) X-ray diffraction (XRD) patterns of pure GMS, solid lipid microparticles (SLMPs) of GMS processed by the Particles from Gas-Saturated Solutions (PGSS) technique (GMS-LID0), SLMPs loaded with LID (GMS-LID4), and pure LID powder. Figure 4. Differential scanning calorimetry (DSC) thermograms of the raw materials, GMS-LID0 and GMS-LID4 particles. No peaks corresponding to crystalline LID were appreciated in the GMS-LID4 particles. 3.2. LID Encapsulation Efficiency Initial LID contents for SLMPs processing were set in the 1–10 wt.% range taking into account the usual LID concentrations in topical LID formulations for pain treatment (0.5–5 wt.%) [42,43] and the high encapsulation efficiencies usually obtained by PGSS technology. Accordingly, LID encapsulation efficiencies for GMS-LID1, GMS-LID2, GMS-LID4, and GMS-LID10 particles were 69.6 ± 4.5%, 59.7 ± 13.6%, 79.0 ± 4.0%, and 75.1 ± 0.9%, respectively. These values correlated well with the encapsulation efficiency of other studies using the PGSS technique for the loading of drugs into microparticles [27], although it is the first time LID is incorporated. CO2 at supercritical conditions can act as a solvent for the drug, so drug loss could take place by the partial dissolution of the drug in scCO2 and its deposition on the walls of the equipment after depressurization [52]. Unlike lidocaine, the hydrochloride salt has no measurable solubility in scCO2 at temperatures up to 45 °C [53]. The solubility of LID in scCO2 may increase at higher temperatures, as it occurs with other anesthetic drugs. Nevertheless, high drug encapsulation efficiencies were herein obtained and related to the solvent-free processing of the particles and absence of downstream steps. LID content in the different SLMPs processed by PGSS (GMS-LID1, GMS-LID2, GMS-LID4, and GMS-LID10) was 0.7 ± 0.0, 1.2 ± 0.3, 3.2 ± 0.2, and 7.5 ± 0.2 wt.%, respectively. The drug contents obtained in the SLMPs are thus compatible with formulations for local drug administration where recommended LID doses are 5–300 mg [42,43]. 1000200030004000 Wavelength (cm -1 ) Transmittance (a.u.) GMS GMS-LID0 GMS-LID4 LID 1542 A 0 20406 0 2θ (º) LID GMS-LID4 GMS-LID0 GMS Intensity (a.u.) B 0 20406080100120140 Temperature (ºC) Heat flow (a.u.) GMS-LID4 GMS-LID0 GMS LID Figure 3. ( A ) Attenuated Total Reflectance/Fourier-Transform Infrared Spectroscopy (ATR/FT-IR) spectra and ( B ) X-ray diffraction (XRD) patterns of pure GMS, solid lipid microparticles (SLMPs) of GMS processed by the Particles from Gas-Saturated Solutions (PGSS) technique (GMS-LID0), SLMPs loaded with LID (GMS-LID4), and pure LID powder. Pharmaceutics 2020, 12, x 8 of 16 Figure 3. (A) Attenuated Total Reflectance/Fourier-Transform Infrared Spectroscopy (ATR/FT-IR) spectra and (B) X-ray diffraction (XRD) patterns of pure GMS, solid lipid microparticles (SLMPs) of GMS processed by the Particles from Gas-Saturated Solutions (PGSS) technique (GMS-LID0), SLMPs loaded with LID (GMS-LID4), and pure LID powder. Figure 4. Differential scanning calorimetry (DSC) thermograms of the raw materials, GMS-LID0 and GMS-LID4 particles. No peaks corresponding to crystalline LID were appreciated in the GMS-LID4 particles. 3.2. LID Encapsulation Efficiency Initial LID contents for SLMPs processing were set in the 1–10 wt.% range taking into account the usual LID concentrations in topical LID formulations for pain treatment (0.5–5 wt.%) [42,43] and the high encapsulation efficiencies usually obtained by PGSS technology. Accordingly, LID encapsulation efficiencies for GMS-LID1, GMS-LID2, GMS-LID4, and GMS-LID10 particles were 69.6 ± 4.5%, 59.7 ± 13.6%, 79.0 ± 4.0%, and 75.1 ± 0.9%, respectively. These values correlated well with the encapsulation efficiency of other studies using the PGSS technique for the loading of drugs into microparticles [27], although it is the first time LID is incorporated. CO2 at supercritical conditions can act as a solvent for the drug, so drug loss could take place by the partial dissolution of the drug in scCO2 and its deposition on the walls of the equipment after depressurization [52]. Unlike lidocaine, the hydrochloride salt has no measurable solubility in scCO2 at temperatures up to 45 °C [53]. The solubility of LID in scCO2 may increase at higher temperatures, as it occurs with other anesthetic drugs. Nevertheless, high drug encapsulation efficiencies were herein obtained and related to the solvent-free processing of the particles and absence of downstream steps. LID content in the different SLMPs processed by PGSS (GMS-LID1, GMS-LID2, GMS-LID4, and GMS-LID10) was 0.7 ± 0.0, 1.2 ± 0.3, 3.2 ± 0.2, and 7.5 ± 0.2 wt.%, respectively. The drug contents obtained in the SLMPs are thus compatible with formulations for local drug administration where recommended LID doses are 5–300 mg [42,43]. 1000200030004000 Wavelength (cm -1 ) Transmittance (a.u.) GMS GMS-LID0 GMS-LID4 LID 1542 A 0 20406 0 2θ (º) LID GMS-LID4 GMS-LID0 GMS Intensity (a.u.) B 0 20406080100120140 Temperature (ºC) Heat flow (a.u.) GMS-LID4 GMS-LID0 GMS LID Figure 4. Differential scanning calorimetry (DSC) thermograms of the raw materials, GMS-LID0 and GMS-LID4 particles. No peaks corresponding to crystalline LID were appreciated in the GMS-LID4 particles. Table 1. Thermal properties of raw materials and GMS particles processed without (GMS-LID0) and with LID (GMS-LID4). Thermal Event LID GMS GMS-LID0 GMS-LID4 Tm(◦C) 78.12 62.28 62.46 60.56 ∆Hm(J/g) 187.0 186.8 179.1 170.9 3.2. LID Encapsulation Efficiency Initial LID contents for SLMPs processing were set in the 1–10 wt.% range taking into account the usual LID concentrations in topical LID formulations for pain treatment (0.5–5 wt.%) [ 42 , 43 ] and the high encapsulation efficiencies usually obtained by PGSS technology. Accordingly, LID encapsulation efficiencies for GMS-LID1, GMS-LID2, GMS-LID4, and GMS-LID10 particles were 69.6 ± 4.5%, 59.7 ± 13.6%, 79.0 ± 4.0%, and 75.1 ± 0.9%, respectively. These values correlated well with the encapsulation efficiency of other studies using the PGSS technique for the loading of drugs into microparticles [ 27 ], although it is the first time LID is incorporated. CO 2 at supercritical conditions can act as a solvent for the drug, so drug loss could take place by the partial dissolution of the drug in scCO 2 and its deposition on the walls of the equipment after depressurization [ 52 ]. Unlike lidocaine, the hydrochloride salt has no measurable solubility in scCO 2 at temperatures up to 45 ◦ C [ 53 ]. The solubility of LID in scCO 2 may increase at higher temperatures, as it occurs with other anesthetic Pharmaceutics 2020,12, 870 9 of 16 drugs. Nevertheless, high drug encapsulation efficiencies were herein obtained and related to the solvent-free processing of the particles and absence of downstream steps. LID content in the different SLMPs processed by PGSS (GMS-LID1, GMS-LID2, GMS-LID4, and GMS-LID10) was 0.7 ± 0.0, 1.2 ± 0.3, 3.2 ± 0.2, and 7.5 ± 0.2 wt.%, respectively. The drug contents obtained in the SLMPs are thus compatible with formulations for local drug administration where recommended LID doses are 5–300 mg [42,43]. 3.3. LID Release Tests SLMPs were suspended in PBS medium at the donor compartment of the Franz diffusion cells, forming a thin layer. A sustained release of LID from the SLMPs was obtained (Figure 5), being at least 50% of the drug payload released after 4 h and the complete release attained after 24 h. The release profile was noticeably delayed with respect to the dissolution profile of pure LID in Franz cells (Figure S2), where more than 85% of the initial amount of LID was quantified after only 15 min, and the complete dissolution took place after 1 h. LID solutions used clinically for local infusion by subcutaneous injection present a duration of action of 0.5–2 h, normally keeping their effect only during a surgical procedure [ 54 ]. SLMPs providing a controlled release of the anesthetic agent could be useful to maintain local anesthesia for longer times, during the first stage of wound healing. Pharmaceutics 2020, 12, x 9 of 16 3.3. LID Release Tests SLMPs were suspended in PBS medium at the donor compartment of the Franz diffusion cells, forming a thin layer. A sustained release of LID from the SLMPs was obtained (Figure 5), being at least 50% of the drug payload released after 4 h and the complete release attained after 24 h. The release profile was noticeably delayed with respect to the dissolution profile of pure LID in Franz cells (Figure S2), where more than 85% of the initial amount of LID was quantified after only 15 min, and the complete dissolution took place after 1 h. LID solutions used clinically for local infusion by subcutaneous injection present a duration of action of 0.5–2 h, normally keeping their effect only during a surgical procedure [54]. SLMPs providing a controlled release of the anesthetic agent could be useful to maintain local anesthesia for longer times, during the first stage of wound healing. Figure 5. Release data of GMS-LID1 (circles), GMS-LID2 (diamonds), GMS-LID4 (triangles), and GMS-LID10 (squares) particles in PBS pH 7.4 at 37 °C and 100 rpm. Lines represent the fittings to a first-order kinetic release with lag time model (Equation (3)). The LID release profile of GMS-LID1, GMS-LID2, GMS-LID4, and GMS-LID10 particles fitted well to a first-order kinetic model (Table 2). The first-order release occurs when the drug release rate is dependent on its concentration. The amount of drug released from the matrix is proportional to the amount remaining, so it tends to decrease with time [55]. The release profile fitted better to a firstorder with lag time kinetic model. The LID dissolution in aqueous media is highly dependent on the hydration of the microparticles, since LID is a hydrophilic drug included within a lipid matrix. The hydrophobic nature of the GMS should delay this hydration and explains the lag times between 0.8 and 1.1 h. Once dissolved, LID release is conditioned by the diffusion of the drug through the lipid matrix. Table 2. Kinetic fitting parameters of LID release profiles from SLMPs in PBS pH 7.4 medium to the first-order and the first-order with lag time kinetic models according to Equations (2) and (3), respectively. SLMPs First-Orde r First-Order with Lag Time k1 (h−1) R2 k2 (h−1) tlag (h) R2 GMS-LID1 0.3047 0.938 0.2532 0.7708 0.966 GMS-LID2 0.2538 0.941 0.2278 0.9049 0.959 GMS-LID4 0.3308 0.963 0.2975 1.066 0.970 GMS-LID10 0.3224 0.985 0.3435 0.4736 0.985 3.4. LID Permeation through Bioengineered Skin Substitutes Topical anesthetics like LID block reversibly the free nerve-ending conductions in the dermis and mucosa. This process can be limited by drug diffusion through the epidermis, since in healthy skin the drug has to pass through the stratum corneum to reach dermal tissue at therapeutic concentrations [56]. The versatility of 3D-bioprinting was exploited in this work to produce different 012345678 24 0 20 40 60 t (h) μg LID released/mg particle Figure 5. Release data of GMS-LID1 (circles), GMS-LID2 (diamonds), GMS-LID4 (triangles), and GMS-LID10 (squares) particles in PBS pH 7.4 at 37 ◦ C and 100 rpm. Lines represent the fittings to a first-order kinetic release with lag time model (Equation (3)). The LID release profile of GMS-LID1, GMS-LID2, GMS-LID4, and GMS-LID10 particles fitted well to a first-order kinetic model (Table 2). The first-order release occurs when the drug release rate is dependent on its concentration. The amount of drug released from the matrix is proportional to the amount remaining, so it tends to decrease with time [ 55 ]. The release profile fitted better to a first-order with lag time kinetic model. The LID dissolution in aqueous media is highly dependent on the hydration of the microparticles, since LID is a hydrophilic drug included within a lipid matrix. The hydrophobic nature of the GMS should delay this hydration and explains the lag times between 0.8 and 1.1 h. Once dissolved, LID release is conditioned by the diffusion of the drug through the lipid matrix. Pharmaceutics 2020,12, 870 16 of 16 47. Hsu, H.-H.; Kracht, J.-K.; Harder, L.E.; Rudnik, K.; Lindner, G.; Schimek, K.; Marx, U.; Pörtner, R. A method for determination and simulation of permeability and diffusion in a 3D tissue model in a membrane insert system for multi-well plates. JoVE J. Vis. Exp. 2018,132, e56412. [CrossRef] [PubMed] 48. Pankey, G.A.; Sabath, L.D. Clinical relevance of bacteriostatic versus bactericidal mechanisms of action in the treatment of Gram-positive bacterial infections. Clin. Infect. Dis. 2004,38, 864–870. [CrossRef] 49. Khosa, A.; Reddi, S.; Saha, R.N. Nanostructured lipid carriers for site-specific drug delivery. Biomed. Pharmacother. 2018,103, 598–613. [CrossRef] 50. Battaglia, L.; Gallarate, M.; Panciani, P.P.; Ugazio, E.; Sapino, S.; Peira, E.; Chirio, D. Techniques for the Preparation of Solid Lipid Nano and Microparticles. In Application of Nanotechnology in Drug Delivery; Sezer, A.D., Ed.; IntechOpen: London, UK, 2014; ISBN 978-953-51-1628-8. 51. Wei, Y.; Nedley, M.P.; Bhaduri, S.B.; Bredzinski, X.; Boddu, S.H.S. Masking the bitter taste of injectable lidocaine HCl formulation for dental procedures. AAPS PharmSciTech 2015,16, 455–465. [CrossRef] 52. Garc í a-Gonz á lez, C.A.; Sousa, A.R.S.; da Argem í , A.; L ó pez Periago, A.; Saurina, J.; Duarte, C.M.M.; Domingo, C. Production of hybrid lipid-based particles loaded with inorganic nanoparticles and active compounds for prolonged topical release. Int. J. Pharm. 2009,382, 296–304. [CrossRef] 53. Weinstein, R.D.; Muske, K.R.; Moriarty, J.; Schmidt, E.K. The solubility of benzocaine, lidocaine, and procaine in liquid and supercritical carbon dioxide. J. Chem. Eng. Data 2004,49, 547–552. [CrossRef] 54. Sweet, P.T.; Magee, D.A.; Holland, A.J.C. Duration of intradermal anaesthesia with mixtures of bupivacaine and lidocaine. Canad. Anaesth. Soc. J. 1982,29, 481–483. [CrossRef] [PubMed] 55. Bruschi, M.L. Mathematical models of drug release. In Strategies to Modify the Drug Release from Pharmaceutical Systems; Elsevier: Amsterdam, The Netherlands, 2015; pp. 63–86. ISBN 978-0-08-100092-2. 56. Manjunatha, R.G.; Sharma, S.; Narayan, R.P.; Koul, V. Effective permeation of 2.5 and 5% lidocaine hydrochloride in human skin using iontophoresis technique. Int. J. Dermatol. 2018 ,57, 1335–1343. [CrossRef] [PubMed] 57. Bazaz, B.S.F.; Salt, W.G. Local anaesthetics as antibacterial agents: Effects on cellular respiration and the leakage of cytoplasmic constituents. Microbios 1983,37, 139–149. 58. Schmidt, R.M.; Rosenkranz, H.S. Antimicrobial activity of local anesthetics: Lidocaine and procaine. J. Infect. Dis. 1970,121, 597–607. [CrossRef] [PubMed] 59. Ohsuka, S.; Ohta, M.; Masuda, K.; Arakawa, Y.; Kaneda, T.; Kato, N. Lidocaine hydrochloride and acetylsalicylate kill bacteria by disrupting the bacterial membrane potential in different ways. Microbiol. Immunol. 1994,38, 429–434. [CrossRef] 60. Hasselmann, C. Determination of minimum inhibitory concentrations (MICs) of antibacterial agents by broth dilution. Clin. Microbiol. Infect. 2003,9, 1–7. [CrossRef] 61. Pelz, K.; Wiedmann-Al-Ahmad, M.; Bogdan, C.; Otten, J.-E. Analysis of the antimicrobial activity of local anaesthetics used for dental analgesia. J. Med. Microbiol. 2008,57, 88–94. [CrossRef] 62. Gajraj, R.J.; Hodson, M.J.; Gillespie, J.A.; Kenny, G.N.; Scott, N.B. Antibacterial activity of lidocaine in mixtures with Diprivan. Br. J. Anaesth. 1998,81, 444–448. [CrossRef] 63. Driver, R.P.; Granus, V.A.; Yassa, Y.J. Growth inhibition of Staphylococcus aureus by propofol/lidocaine admixture. Anesth. Analg. 1998,86, 166S. [CrossRef] 64. Johnson, S.M.; John, B.E.S.; Dine, A.P. Local anesthetics as antimicrobial agents: A review. Surg. Infect. 2008 , 9, 205–213. [CrossRef] © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).