Full text
Atmospheric Temperature Effect in Secondary Cosmic Rays Observed With a 2 m 2 Ground‐Based tRPC Detector Irma Riádigos 1 , Damián García‐Castro 2 , Diego González‐Díaz 2 , and Vicente Pérez‐Muñuzuri 1 1 CRETUS Institute, Group of Nonlinear Physics, Faculty of Physics, University of Santiago de Compostela, Santiago, Spain, 2 Instituto Galego de Física de Altas Enerxías, Faculty of Physics, University of Santiago de Compostela, Santiago, Spain Abstract A high time resolution 2 m 2 tracking detector, based on timing Resistive Plate Chamber (tRPC) cells, has been installed at the Faculty of Physics of the University of Santiago de Compostela (Spain) in order to improve our understanding of the cosmic rays arriving at the Earth's surface. Following a short commissioning of the detector, a study of the atmospheric temperature effect of the secondary cosmic ray component was carried out. To take into account this effect, temperature coefficients, W T (h), were obtained from cosmic ray data using a method based on Principal Component Analysis (PCA). The results obtained show good agreement with the theoretical expectation. The method successfully removes the correlation present between the different atmospheric layers, which would be dominant otherwise. We briefly describe the initial calibration and pressure correction procedures, essential to isolate the temperature effect. Overall, the measured cosmic ray rate displays the expected anticorrelation with the effective atmospheric temperature, through the coefficient α T =−0.279±0.051%/K. Rates follow the seasonal variations, and unusual short‐term events are clearly identified too. 1. Introduction Cosmic rays (c.r.) are messengers from outer space that provide valuable information for different research areas, such as space weather, high‐energy physics, and cosmology (Hayashi et al., 2005; Pierre Auger Collaboration, 2015). Specifically, ground‐based instruments give us the chance to study the products of the interactions between primary cosmic rays and the nuclei in the atmosphere. These products consist of secondary particles that traverse the atmosphere carrying information about its inner structure, as in a radiography, providing information about its properties. Secondary muons, in particular, are affected by atmospheric pressure and temperature. These induce local modifications of the atmospheric density and its depth, thereby changing the balance between particle production, absorption and decay, affecting the muon rates at the ground (Dorman, 2004). Since modern muon detectors are mostly committed to the study of solar activity and other astrophysical phenomena, such effects are regularly removed with simple techniques, as part of a calibration procedure (De Mendonça et al., 2013). Our work is concerned with a deeper comprehension of such atmospheric effects. The rates of c.r. measured at the Earth's surface vary according to changes in several atmospheric conditions, chiefly the pressure at ground level and the temperature profile of the atmosphere. The pressure (or barometric) effect arises mainly due to the absorption of the radiation in the atmosphere through energy loss. The more the pressure, the more air mass to traverse. Therefore, secondary c.r. particles are more efficiently absorbed, and, consequently, the measured rates are modulated in anticorrelation with the ground‐level pressure. In detail, the mass increase is associated with a larger height of the air column, which modifies the decay probabilities of the particles involved, implying a nonnegligible (but subdominant) contribution to the main negative correlation (Sagisaka, 1986). In the absence of variations in the ground‐level pressure, the modification of the local density of the air column as a result of temperature variations modifies c.r. rates as well. This so‐called “temperature effect”is the result of two contributions: the interaction (positive correlation) and decay (negative correlation) of secondary particles through the atmosphere. Muons (μ +/− ), which are the dominant c.r. particles at ground level, originate mainly from the decay of charged pions and kaons (π +/− ,K +/− ). Since an increase in temperature ©2020. The Authors. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. RESEARCH ARTICLE 10.1029/2020EA001131 Key Points: •Atmospheric temperature effect isolated with timing resistive plate chambers for the first time •Extraction of temperature coefficients versus atmosphere depth through principal component regression and comparison with theoretical expectation •Seasonal and occasional variations for the cosmic ray flux observed show consistency with earlier Global Muon Detector Network results Correspondence to: I. Riádigos, [email protected] Citation: Riádigos, I., García‐Castro, D., González‐Díaz, D., & Pérez‐Muñuzuri, V. (2020). Atmospheric temperature effect in secondary cosmic rays observed with a 2 m 2 ground‐based tRPC detector. Earth and Space Science, 7, e2020EA001131. https://doi.org/ 10.1029/2020EA001131 Received 10 FEB 2020 Accepted 30 MAY 2020 Accepted article online 11 JUN 2020 RIÁDIGOS ET AL.1of14
reduces the atmospheric density, causing a reduction in the interaction probability, more pions and kaons will decay and produce more muons. Muons, unlike their parents, are highly penetrating, and small changes in their interaction probability leave their behavior largely unaffected. As a result, the surface rates increase with increasing temperature, creating a positive effect. The negative effect is related to the muon decay itself. Because the atmosphere also expands when the temperature increases, muons have to travel further to reach the surface before they decay. As a result, the surface rates decrease. Importantly, in case of high‐energy particles, the positive effect dominates because of time dilation in the muon reference frame. This relativistic effect causes energetic muons to effectively live longer, so their decay probability is reduced. For low energies, on the other hand, the dominant effect is negative. A practical way to ‘increase’the particle energy is to measure the c.r. rates underground, thus allowing to study the temperature effect as a function of the rock overburden (e.g., Abrahao et al., 2017). The temperature effect can be nearly one order of magnitude smaller than its pressure counterpart, requiring a much better control on systematic effects of instrumental origin and high statistics (detector size) in the first place. A precise estimate of the atmospheric temperature effect involves an implementation of the “integral method,”which requires, on the one hand, knowing the temperature profiles above the detector and, on the other hand, knowing the distribution of temperature coefficients (W T ), the latter accessible by theoretical means (Dmitrieva et al., 2011). Given that the detector used in this work was conceived to potentially make use of both the soft (electron) and hard (muon) cosmic ray component, the temperature coefficients (calculated for muons) are not known a priori. As discussed afterward, the effect of the material overburden cannot be completely neglected nor easily characterized, either. The main purpose of this work is to experimentally obtain the temperature coefficients for secondary cosmic rays at ground, resorting to a technology not used previously in these kind of studies. We will show how, despite the much higher dark rates customary of gaseous detectors as compared to plastic scintillators, two ∼2m 2 planes of timing Resistive Plate Chambers (tRPCs) operating at ground level are sufficient to isolate the temperature effect, a fact that results largely from the superb timing characteristics of the device. 2. The Cosmic Ray Detector The tRPC technology was introduced to particle physics back in 2000 as a byproduct of the R&D program of the ALICE experiment at the Large Hadron Collider (Fonte et al., 2000). Indeed, tRPCs have been adopted already for the study of high‐energy cosmic rays by the EEE collaboration (Abbrescia et al., 2013), but no study on the temperature effect has been reported by the collaboration yet. tRPCs represent a family of nonproportional gaseous detectors, generally characterized by the use of thin submillimeter gas gaps operated in Figure 1. (a) Drawing of the muon telescope at Santiago de Compostela, showing the tRPC layout with some illustrative examples of different particle interactions. In the present analysis only the T2 and T4 RPC planes are used. (b) Inner view of the detector. 10.1029/2020EA001131 Earth and Space Science RIÁDIGOS ET AL.2of14
“fast”well‐quenched gas mixtures at very high electric fields (up to ∼150 kV/cm). Stability of operation requires the use of insulating materials with high surface quality, something conventionally achieved through soda‐lime glass. tRPCs can make an optimal use of the multigap technique (Cerrón Zeballos et al., 1996), which allows for the systematic stacking of several gas gaps, in order to achieve time resolutions down to 20 ps in special configurations (An et al., 2008). In fact, tRPCs have recently demonstrated the capability of reaching 60 ps on 2 × 2 m 2 areas, with a modest number of electronic readout channels around 160, and a position resolution at the centimeter scale (Watanabe et al., 2019). At the University of Santiago de Compostela (Spain), a medium‐size tRPC detector (1.2 × 1.5 m 2 ) with a space andtimeresolution of σ x,y ∼3 cmandσ t ∼300 ps,respectively,hasbeen installed circa 2014 aspartoftheTrasgo Project (Belver et al., 2010; Blanco et al., 2014). It is named TRAGALDABAS (TRAsGo for the AnaLysis of the nuclear matter Decay, the Atmosphere, the earth B‐Field And the Solar activity), and it has been designed and built at LabCAFin collaboration with LIP(e.g., Abreuet al.,2018). Theangular resolutionwith its presentvertical layout is 2–3° and the maximum zenith angle of the accepted tracks is close to 50° (Figure 1a). Unlike other cosmic ray detectors, TRAGALDABAS has a relatively small active area of 1.8 m 2 . For comparison, the MuSTAnG detector (Hippler et al., 2008) had a surface of 4 m 2 and all four telescopes of the Global Muon Detector Network (GMDN) extend over around 15–30 m 2 (Rockenbach et al., 2014). The detector consists of four RPC planes with a total height of 1.8 m (Figure 1a). Each plane's inner design is based on three plates of 2 mm glass with a 1 mm gas gap interleaved, placed inside a gas‐tight acrylic box. Tetrafluoroethane, a type of freon (R134a, CF 3 CH 2 F), is used as the active medium, at a very low flow, just sufficient to keep the detector efficiency constant over time. It operates at a pressure of few mbar over atmospheric pressure (in order to mitigate air backflow at the exhaust, but at the same time avoiding mechanical stress). The external sides of the outer glass plates are covered with a semiconductive coating (acrylic paint) to which a ±5,600 V high voltage is applied. Electrical pick‐up signals, stemming from the avalanches produced in the gas upon the passage of a charged particle, are induced in some of the 120 copper pads (each one with an area of 111 × 116 mm 2 ) placed outside of the acrylic box (Figure 1b). Those signals are processed with fast ∼1 GHz BW electronics (Belver et al., 2010), and, if above an adjustable threshold, a digital LVDS (low‐voltage differential signaling) signal is produced, marking the passage of the particle (we will refer to the associated pad and plane as “fired”). A flexible trigger condition can be formed for any number of fired planes and pad multiplicity per plane, a digital signal formed, correspondingly, and sent to the acquisition in order to store the c.r. candidate. The telescope is placed at ∼260 m above sea level, 42°52'N 8°33'W, at a geomagnetic rigidity cutoff of ∼5.5 GV, in the first floor of a two‐story building. It is running since 2015 with a room temperature stable at 20 ± 1°C. It is important to note that, except in special configurations (e.g., Blanco et al., 2015; Margato et al., 2019), RPC detectors have intrinsically a very low detection efficiency for neutrons below 10 MeV, not exceeding 0.1%. Moreover, neither the products from neutron interactions nor electrons from neutron decay at these energies can traverse a second detection plane, as required in present analysis. Hence, if assuming a typical albedo neutron flux of ∼1 kHz/cm 2 (Hubert et al., 2016), the detector can be effectively considered as neutron blind, for the purposes of present analysis. 3. Input Data and Processing We report here data from the commissioning phase and early physics run (from October 2015 to January 2017), where only two detector planes, stacked over a height of 120 cm, were used (T2 and T4 in Figure 1a). A trigger condition was defined as “at least one fired pad per plane, in time coincidence.” During data analysis, a standard equalization is performed in an automatic way, aimed at the correction of the channel‐by‐channel variations in the time offsets and signal amplification (along the lines of Kornakov, 2014). Provided both charge and time information are stored for each pad, noise signals (displaying zero charge) can be removed in the next processing step. Finally, ‘particle tracks’are formed by combinatorially matching the fired pads in both planes with a velocity compatible with the speed of light, within a 3‐σ t interval, σ t being the time resolution of the detector. This produces the final data sample ready for physics analysis, where any instrumental effects should be greatly minimized. We use in this work a data subsample, corresponding to events with a single track (multiplicity M= 1), and a zenith angle θlower than 13°. 10.1029/2020EA001131 Earth and Space Science RIÁDIGOS ET AL.3of14
The former condition means that only cases with one fired pad per plane have been considered. The resulting mean rate is R= 9.05 Hz. The complete data taking period, displayed in Figure 2, may be conveniently divided in three phases: •From October 2015 to June 2016. During this first period the detector was run semi‐autonomously (several interventions were needed) and problems related to faulty front‐end electronics and high voltage instabilities were observed. •From June 2016 to October 2016. Maintenance work was carried out, the faulty electronics modules were replaced, and an online monitor developed. •From October 2016 to January 2017. The detector run in stable conditions, in a fully autonomous way. Concerning the atmospheric variables, the vertical temperature profiles were retrieved from the European Centre for Medium‐Range Weather Forecast (ECMWF) reanalysis, ERA‐Interim (Dee et al., 2011), for the 1979–2017 period, at 37 isobaric levels (1,000, 975, 950, 925, 900, 875, 850, 825, 800, 775, 750, 700, 650, 600, 550, 500, 450, 400, 350, 300, 250, 225, 200, 175, 150, 125, 100, 70, 50, 30, 20, 10, 7, 5, 3, 2, and 1 hPa), with a horizontal spatial resolution of 0.125° and a temporal resolution of 6 hr. Two exemplary profiles for summer and winter are shown in Figure 3. The surface pressure data is provided by a weather station of the Galician Regional MetOffice (MeteoGalicia) located at ∼100 m from the detector. 4. Analysis of Atmospheric Effects As mentioned before, several methods can be used to take into account the temperature effect of secondary cosmic ray particles in the atmosphere (Blackett, 1938; Berkova et al., 2011; Dorman, 2004; Duperier, 1949; Sagisaka, 1986). The integral method has been shown to be one of the most precise (De Mendonça et al., 2016; Dmitrieva et al., 2013), but it requires knowing the distribution of the temperature coefficients in the atmosphere, W T (h). These can be theoretically calculated for different threshold energies, zenith and azimuth angles of incidence (Dmitrieva et al., 2011), or extracted from c.r. data (Yanchukovsky & Kuzmenko, 2018). In this work we compare both approaches. An experimental determination of W T (h) is not straightforward and requires special statistical techniques, given the presence of strong correlations between the temperatures of the different atmospheric layers. For illustration, Figure 4a shows a scatter plot of the temperatures corresponding to two different layers, from January 2015 to December 2016, and Figure 4b shows the pairwise correlation matrix obtained for the temperatures of the different atmospheric layers on top of the detector for the same period. In general, the low stratosphere (∼250–70 hPa) behaves opposite to the troposphere (∼1,000–250 hPa) and high Figure 2. Cosmic ray rate for single vertical tracks as observed with the muon telescope (black curve) and ground‐level pressure (blue curve). 10.1029/2020EA001131 Earth and Space Science RIÁDIGOS ET AL.4of14
stratosphere (∼70–1 hPa). This is because the boundary layer (∼925 hPa) is positively correlated with the rest of the troposphere through convection, while an increase in its temperature will generally result in the low stratosphere cooling down. This is a typical condition observed for latitude regions above 40° (Liu et al., 2014). Consequently, any attempt to obtain the temperature coefficients by means of a multivariate regression will result in coefficients whose values do not correspond to the actual values. If explanatory variables of a multiple regression model are strongly correlated, they provide redundant information and violate the condition of noncollinearity required in a least squares regression. The coefficients will also be highly sensitive to small changes in the model and their sign will be dramatically dependent on the variables considered. In other words, slightly different models might lead to different conclusions. In this way, we would never know the actual effect of each variable. Clearly, any phenomenological model aimed at reliably describing the measured rates needs to start from a sensible set of uncorrelated temperature variables that need to be obtained beforehand. We adapt for the task the principal components regression (PCR) analysis, which has been successfully used before for this type of studies in (Savićet al., 2019; Yanchukovsky & Kuzmenko, 2018). 4.1. Barometric Effect Being much subtler, the temperature effect must be analyzed once the pressure effect has been removed. Moreover, in the case of gaseous detectors, the efficiency is a function of the ratio of applied electric field Eand pressure P(represented by E/Pand dubbed reduced field), so even a high voltage and T‐controlled environment is not sufficient to stabilize the detector response completely (Lopes et al., 2016). The above dependency means that the detector efficiency is anticorrelated with pressure and will add to the barometric effect at ground. Considering the atmospheric effect first, the relative change in the secondary c.r. rate caused by variations of the ground‐level pressure has an exponential dependence. To first‐order approximation, it can be expressed through a linear relation: R R0 ¼eβatm ·ΔP→ ΔR R0P ≈β·ΔP(1) where ΔR R0Pis the relative variation of the c. r. rate due to the pressure effect, R 0 represents its average value Figure 3. Examples of ERA‐INTERIM atmospheric temperature profiles for Santiago de Compostela, summer (1 July 2016) and winter (1 January 2017). Figure 4. (a) Correlation between temperatures for the atmospheric layers i= 125 hPa and j= 700 hPa (T 0i,j is the mean value of each layer). (b) Pairwise correlations between temperatures of the different pressure levels considered in this analysis for Santiago de Compostela (from January 2015 to December 2016). 10.1029/2020EA001131 Earth and Space Science RIÁDIGOS ET AL.5of14
over the period under consideration, ΔP=P−P 0 is the deviation of the ground‐level pressure with respect to its mean value (P 0 ) over the same period, and β=β atm +β det is the barometric coefficient, with β atm representing the atmospheric effect and β det the detector contribution. The barometric coefficient was obtained separately for four different subperiods that displayed slightly different stability conditions (Table 1). An iterative linear fit was performed, with data outside a 2‐σinterval removed from the fit (Figure 5). Compatible barometric coefficients were obtained, whose mean value was determined to be β=−0.59 ±0.02%/hPa. This methodology allows us to remove any outliers in the data caused by detector instabilities and occasional space weather effects such as Forbush decreases or interplanetary events. Finally, the barometric effect is removed using ΔR R0T ¼ΔR R0obs − ΔR R0P (2) where ΔR R0obs are the experimental c.r. variations and ΔR R0Tthe remaining variations due to the temperature effect. 4.2. Temperature Effect Variations of the measured rate of the secondary c.r. component due to the atmospheric temperature effect can be approximated by a linear combination of some temperature coefficients and the temperature variations of natmospheric layers (Dmitrieva et al., 2011): ΔR R0T ¼∑ n i¼1 WTðhiÞΔTiΔhi(3) where ΔR R0Tare the relative variations due to the temperature effect; W T , given in % K −1 atm −1 , is the corresponding temperature coefficient for the atmospheric layer iat pressure h i ;ΔTi¼Ti−T0iare the temperature variations within the same layer with respect to its mean value (T0i), and Δh i =h i−1 −h i is the layer thickness, in atm. Defining kxi¼WTðhiÞΔhi, Equation 3 can be rewritten as ΔR R0T ¼∑ n i¼1 kxiΔTi(4) that we denote formally as y¼Xkx(5) where yis the vector of the measured relative variations ΔR R0T;Xis the (m×n) data matrix of the temperature variations whose columns are the temperature variations of the ith pressure level and k x refers to the vector of temperature coefficients that we want to estimate. As mentioned earlier, the coefficients of this model can not be obtained by ordinary regression. For our purpose, we decided to use the Principal Component Regression (PCR) technique (Jolliffe, 2002). This method is applied when a data set of variables shows multicollinearity, in our case the temperature variations. The idea is to build new uncorrelated variables (called principal components), maintaining the information conveyed by the original ones, and use them as the new predictors to estimate the unknown regression coefficients of the model. Table 1 Barometric Coefficients for the Different Subperiods Period β(%/hPa) 3 October to 23 December 2015 −0.607 ± 0.003 24 December 2015 to 20 September 2016 −0.602 ± 0.002 21 September to 22 November 2016 −0.583 ± 0.003 23 November 2016 to 10 January 2017 −0.568 ± 0.002 Figure 5. Example of the linear fit method used to obtain the barometric coefficient for one of the subperiods (3 October to 23 December 2015). The green lines delimit the points left out of a 2‐σinterval after an iterative procedure. The blue line is the resulting regression line. 10.1029/2020EA001131 Earth and Space Science RIÁDIGOS ET AL.6of14
The PCA consists of an orthogonal linear transformation that converts the original variables to a new coordinate system. The principal components (PCs) represent the directions of the data containing the greatest variance. So, the first step is standardizing the ΔT i measurements in X, dividing them by their standard deviations (over the analyzed period). This standardization is needed to prevent the variables with the highest variance from dominating. It causes a change in the notation, too. To keep it simple, we maintain the current notation but taking into account that all the following calculations are based on standardized variables. The principal components are the eigenvectors (directions) obtained from the covariance matrix of Xand sorted by the amount of explained variance. This set of orthogonal vectors forms a new basis in the new coordinate system. The matrix Xcan be transformed using the matrix of eigenvectors, defined as A(n×n), in the following way P¼XA (6) where Pis now the matrix (m×n) containing the new variables in the new space. We got a set of uncorrelated variables because they were built using orthogonal eigenvectors. As a consequence, a new model can be built using variables P: y¼Pkp(7) Now, the new set of coefficients k p can be obtained directly using a least squares regression. Taking into account Equation 6, we can write y¼XAkp(8) The regression coefficients k p can be transformed back into the original space using Equations 5 and 8 kx¼Akp(9) and multiplying by standard deviations in order to go back to the original scale. The year‐to‐year variability of the temperature data may affect the determination of the principal components, particularly if exceptional temperature changes took place during the data acquisition period, such as sudden stratospheric warmings. This can be seen in Figures 6 and 7, where several stratospheric temperature anomalies (warmings and coolings) can be seen during winter periods. Therefore, as a first step we use a training dataset from a time series of the last 30 years to determine the PCs of the temperature data and avoid the influence of outliers corresponding to exceptional events. PCR typically uses only a significant subset of all the principal components P′to increase reliability. The components with higher variances are usually selected as the regressor variables for being the most Figure 6. Temperature time series of the atmosphere in Santiago de Compostela from October 2015 to January 2017. 10.1029/2020EA001131 Earth and Space Science RIÁDIGOS ET AL.7of14
important. No standard method exists for deciding how many components to retain. Anyhow, a good number of components should carry a high percentage of the total variance (>70%). In order to decide the number of PCs to keep, we previously performed an analysis with reconstructed cosmic ray variations using a theoretical distribution of the temperature coefficients as a proxy (Dmitrieva et al., 2011). These variations represent ideal data (i.e., without noise) only affected by the atmospheric temperature. Then, we apply the PCR method to these data to see how many PCs need to be kept in order to retrieve the original coefficients. To make this study more realistic, we follow the typical procedure of adding extra noise to the original data in three levels (low, medium, and high) to be able to analyze the performance of the technique. It was observed that with two components it is possible to restore the correct values of the coefficients until an acceptable level of noise. Including more components destabilizes the result. Finally, the vector of coefficients k′ pis estimated by regressing the observed vector of cosmic ray data on the selected principal components P′using least squares regression. So Equation 7 is reduced to Figure 7. Temperature anomaly for March 2016 were an example of a sudden stratospheric warming is observed in the first half of the month. The upper stratosphere warms rapidly in a few days propagating way down into the troposphere in the next weeks. Figure 8. (a) Distribution of temperature coefficients obtained with PCR for vertical tracks and comparison with the theoretical distribution for different energy thresholds: 0.15, 0.32, 0.75, 1, and 3.2 GeV. (b) Slopes ~ WTobtained through a direct linear regression for the same data sample (θ< 13°). 10.1029/2020EA001131 Earth and Space Science RIÁDIGOS ET AL.8of14
y¼P′k′ p(10) where P′is now a matrix (m×r) whose columns are the corresponding subset of columns of P(and r<n). Using Equation 9, k′ pcan be transformed back to the space of the actual temperature variables, providing the regression coefficients k x that characterize the original model. Also, the relation kxi¼WTðhiÞΔhiintroduced before is taken into account when converting the estimated regression coefficients to the distribution of temperature coefficients W T , having a dimension %/K·atm. It must be noted that partial least squares (PLS) regression could be an alternative to this technique because it is similar to PCR in that both select components that explain the most variance in the model. The difference is that PLS incorporates the response variable (the c.r. rate, in this case) into the analysis. One of the main reasons for not using this method is that our set of cosmic rays measurements is limited to a period of just two years. 5. Results and Discussion Figure 8a shows the distribution of temperature coefficients for the secondary c.r. component recorded at sea level for vertical incidence (blue line), where only events with a zenith angle θlower than 13° were selected. The PCR method was applied to four different subperiods of the data in order to account for systematic effects, expected to be mostly of instrumental origin at this stage, but also any remaining space weather phenomena having similar timescales to temperature variations. The average value and error bars are obtained from this combined analysis. As mentioned, the detector is placed in the first floor of a two‐floor building. Therefore, the composition of the overburden material has been taken into account to estimate the value of the muons threshold energy, E th ∼0.15 GeV, which is important to compare our coefficients with the theoretical ones (these can be found on the basis of integrations of the distributions describing muon production and propagation in the atmosphere). For illustration, the theoretical distributions for different muon energy thresholds and zenith angle θ= 0°(gray lines in Figure 8a) as given in Dmitrieva et al. (2011) are shown. A good agreement with the ones obtained with PCR is observed for low thresholds, while above 0.75 GeV a systematic deviation appears, specially close to ground level. Although being compatible, the estimated values in the troposphere (>300 hPa) are systematically above the theoretical ones. This might be a consequence of the method itself but could as well reflect the presence of the soft component in the measured rates, given that it anticipates a positive correlation with the lower layers of the atmosphere (Dorman, 2004). The values also differ at high altitudes, in this case due to the constraint in the selection of the number of principal components in the analysis. The PCR method computes the principal components taking into account the variance in the temperature data. Then, the first components reproduce the general variations in the troposphere and stratosphere (seasonal changes). Variations in the high atmosphere are considerably more complex than in the surface, as illustrated in Figure 4. Increasing the selected number of components would help to reduce this effect in an ideal situation. However, the optimum number of selected components in our case is the one that allows to obtain the best results of the coefficients without the solution being destabilized by noise and other instrumental effects. On the other hand, it should be noted that the accuracy of the ECMWF reanalysis is worse at high altitudes (0–200 hPa) due to the lack of data (less satellite/balloon observations, etc.), so the temperatures have an inherent source of error that surely increases the difficulties in obtaining the coefficients at those heights. Figure 8b shows for illustration the slopes determined before applying the PCR. Each coefficient ~ WTis obtained by direct regression between the relative variations of the c.r. intensity and the temperature variations for different layers: ΔR R0T ¼∼WTðhiÞΔTiΔhi(11) These coefficients are dominated by the multiple correlations between the atmospheric layers. In particular, the slopes in the troposphere are negative, become positive in the low stratosphere and return to negative values in the high stratosphere. The distribution of temperature coefficients, W T (h), indicates that the 10.1029/2020EA001131 Earth and Space Science RIÁDIGOS ET AL.9of14