scieee AI-readable full text Open interactive document viewer

Defining the most eco-efficient vehicle paint shop in view of formaldehyde emissions performance

Granadero Rey, Daniel

Abstract

This Ph.D. thesis assesses the impact of the change in the hazardous classification of formaldehyde in vehicle paint shops from an environmental and economic perspective. This work includes an evaluation of compliance with the applicable emission limit value for formaldehyde, a proposal of options to reduce the emissions and their economic impact, a Life Cycle Assessment of the painting process in a real vehicle paint shop and an eco-efficiency analysis. The outcomes of this thesis allowed to make a proposal for the most eco-efficient vehicle paint shop in view of formaldehyde emissions performance.

Full text

INTERNATIONAL DOCTORAL SCHOOL OF THE USC Daniel Granadero Rey PhD Thesis DEFINING THE MOST ECOEFFICIENT VEHICLE PAINT SHOP IN VIEW OF FORMALDEHYDE EMISSIONS PERFORMANCE Santiago de Compostela, 2023 Doctoral Programme in Chemical and Environmental Engineering TESE DE DOUTORAMENTO DEFINING THE MOST ECO-EFFICIENT VEHICLE PAINT SHOP IN VIEW OF FORMALDEHYDE EMISSIONS PERFORMANCE Autor Daniel Granadero Rey Directores: Dr. Francisco Omil Prieto e Dr. Gumersindo Feijoo Costa Titor: Dr. Francisco Omil Prieto PROGRAMA DE DOUTORAMENTO EN ENXEÑARÍA QUÍMICA E AMBIENTAL SANTIAGO DE COMPOSTELA Confidentiality Note This industrial Ph.D. thesis has been carried out under a strict confidentiality agreement between the company Opel Automobile GmbH and the University of Santiago de Compostela. Hence, the original work contains confidential information and data that belong to the company. This is a reduced version in which any sensible and/or confidential information has been removed. Acknowledgements I would like to use these lines to express my gratitude to all those people who helped me directly or indirectly in the completion of my doctoral thesis. First and foremost, I am indebted to Dr. Renate Adam, Manager of the Environmental Compliance and Sustainability department and my supervisor at the company Opel. She gave me the opportunity to conduct this work and provided me with support, advise and understanding throughout all these years. I would also like to thank her for the dedicated time and contribution in the publication of the research article on the LCA of the painting process. I also wish to thank my supervisors at the University, Prof. Dr. Francisco Omil and Prof. Dr. Gumersindo Feijoo, who offered me the excellent chance to carry out this thesis at their research group. I am very grateful for their guidance and supervision during this long and arduous journey. I very much appreciate their flexibility in finding time to answer my questions and correct my work. I am particularly thankful for the collaboration of Aida García Muñoz, who performed her master thesis under my supervision at the company. Her contribution made possible the elaboration of the chapters on LCA and eco-efficiency. I also thank Dr. Ana Arias Calvo for her advice on the publication of the mentioned research article and on the organizational issues related to the thesis submitting process, and my former colleague and friend Dr. Jorge Bordello, who shared his research journey with me during my first “doctoral life” at the University. The memories of that time motivated me to accomplish this objective. I would like to thank my colleagues at Opel and all company engineers and specialists that helped me in some way in the development of this work. I do not forget to thank the most important people in my life. My mother Isabel, for her unconditional support and understanding. She is largely responsible for who I am today. A special mention to my father José Ángel, who sadly passed away last year. I know that, in one way or the other, he accompanies me and gives me strength to achieve my goals. My wife Martina, who not only shares her life with me but also fills mine with happiness and love. Without her help and encouragement, I would not have been able to finalize this work. Finally, my daughters Lúa and Soley, who are the reason I get up every day (in every sense). I am thankful for each minute I spend with them. They could not make me happier and prouder. Last but not least, thanks to the rest of my family and friends who are and were with me in the difficult moments. Thank you. Abbreviations ALO Agricultural Land Occupation BC Basecoat BiW Body in White BREF Best Available Techniques Reference Document CC Clearcoat (chapter 1) CC Climate Change (all other chapters) CLP Regulation on classification, labelling and packaging of substances and mixtures COD Chemical Oxygen Demand CP Cavity Preservation (wax) DNPH 2,4-Dinitrophenylhydrazine EC Electrocoating ELV Emission Limit Value EU European Union FD Fossil Depletion FE Freshwater Eutrophication FET Freshwater Ecotoxicity HPLC High-Performance Liquid Chromatography HT Human Toxicity IR Ionizing Radiation JPH Jobs Per Hour LCA Life Cycle Assessment LCI Life Cycle Inventory LCIA Life Cycle Impact Assessment MD Metal Depletion ME Marine Eutrophication MET Marine Ecotoxicity MSDS Material Safety Datasheet NLT Natural Land Transformation OD Ozone Depletion PHO Phosphating PMF Particular Matter Formation POF Photochemical Oxidant Formation PR Primer application PT Pretreatment PT-EC Pretreatment and Electrocoating PVC Polyvinyl Chloride RTO Regenerative Thermal Oxidizer SB Solvent based coating. SB'1k Solvent based one-component SD Sealing and dumping S1 System 1 SS1 Subsystem 1 SS2 Subsystem 2 SS3 Subsystem 3 STS Surface Treatment Using Organic Solvents TA Terrestrial Acidification TC Topcoat (Basecoat + Clearcoat) TET Terrestrial Ecotoxicity TOC Total Organic Carbon ULO Urban Land Occupation VOC Volatile Organic Compound WB Water based WD Water Depletion WWTP Wastewater Treatment Plant Resumo 3 • En segundo lugar, a estrutura melamina-formaldehído rómpese durante o proceso de curado de pintura dentro dos fornos de secado a altas temperaturas, liberando formaldehído que se emitirá á atmosfera se non se instala ningún equipo de redución de emisións ou se o sistema de redución non é capaz de eliminar o formaldehído. Esta hipótese analízase a fondo no capítulo 2. As seis plantas de pintura da empresa foron consideradas neste traballo para a avaliación das emisións de formaldehído. Levouse a cabo unha avaliación exhaustiva de cada planta como etapa preparatoria para o estudo realizado no capítulo 2. No capítulo 1 indícanse as diferentes características e condicións de traballo de cada planta. En canto ás opcións para reducir ou eliminar as emisións de formaldehído, faise unha distinción entre as emisións de formaldehído libre das cabinas de pintado e as emisións dos fornos de secado. En canto á primeira, a purificación das pinturas para reducir a concentración de formaldehído libre é a medida máis adecuada. A opción elixida polos fabricantes de pintura foi mellorar os procesos de fabricación da resina para eliminar as impurezas do formaldehído. Para eliminar ou reducir as emisións de formaldehído dos fornos de secado, pódense considerar dúas tecnoloxías alternativas. A primeira opción é a instalación dun oxidador térmico rexenerativo (RTO en inglés). Este equipo consta de varios leitos con recheo cerámico onde o proceso de oxidación ten lugar nunha serie de pasos alternos de quecemento e arrefriado. A segunda alternativa é a oxidación térmica recuperativa, que consiste nunha cámara de combustión única na que se produce a oxidación dos COV. Ambos tipos de tecnoloxía poden tratar todos os gases residuais dos fornos de secado e baséanse nos principios da oxidación térmica. As características de cada tecnoloxía explícanse no capítulo 1. Capítulo 2. Inventario das emisións de formaldehído No capítulo 2 descríbese a primeira investigación realizada nas seis plantas de pintura de vehículos da empresa en relación coas medicións das emisións de formaldehído. Neste capítulo explícanse a elaboración dos programas de medición e as metodoloxías aplicadas para as medicións. Posteriormente, examínanse e expóñense os resultados tendo en conta a hipótese enunciada no capítulo 1. Identifícanse as plantas de pintura e os procesos que requiren medidas correctivas para garantir o cumprimento do valor límite de emisión aplicable e propóñense medidas específicas para a redución das emisións de formaldehído. Por último, móstranse os datos de inventario das emisións de formaldehído utilizados para a análise de ciclo de vida (ACV) desenvolto no capítulo 3. Para realizar as medicións das concentracións de formaldehído, elaboráronse programas de medición específicos para cada planta de pintura. Seleccionáronse e incluíron nos programas as chemineas pertinentes dos procesos afectados. En xeral, o alcance das medicións incluíu os gases residuais das cabinas de pintado, as zonas de flash off e os fornos de secado dos subprocesos de cataforese, imprimación, capa de pintura base e capa de laca clara. En casos específicos, tamén se incluíron os gases residuais procedentes de operacións menores como o selado de PVC ou a aplicación de ceras. Neste capítulo indícanse os puntos de medición específicos de cada planta, así como as condicións de funcionamento durante a mostraxe. As medicións leváronse a cabo por empresas de medición dispoñibles na rexión onde se atopa a planta de produción. Estas empresas foron seleccionadas tras un exame preliminar que asegurou que contasen coa acreditación e os coñecementos necesarios para a mostraxe e a análise das medicións das emisións de formaldehído. As empresas aplicaron tres metodoloxías diferentes (DNPH Method – Impinger Method, XAD-2 Collection Tubes Method and DANIEL GRANADERO REY 4 Multicomponent FTIR Gas Analyzer), en función da súa dispoñibilidade e acreditación. Estas metodoloxías descríbense en detalle neste capítulo. Os resultados das medicións confirman e validan a hipótese enunciada no capítulo 1. As concentracións observadas nos gases residuais das cabinas de pintado en todas as plantas foron tipicamente inferiores a 0.5 mg/m3 e, por tanto, moi inferiores ao valor límite de emisión aplicable. Isto indica que as emisións das cabinas non son motivo de preocupación desde o punto de vista legal. Pola contra, as concentracións atopadas á saída dos fornos de secado superan significativamente o valor límite de emisión, con resultados que alcanzan 88.3 mg/m3. Os resultados tamén demostran que as altas concentracións de formaldehído despois do forno poden reducirse con éxito a valores inferiores ao valor límite de emisión aplicable se se instala un equipo de redución para tratar o gas residual do forno e este opérase correctamente. As dúas tecnoloxías consideradas, é dicir, a oxidación térmica rexenerativa e recuperativa, puideron reducir o formaldehído obtendo resultados similares. Tendo en conta estes resultados, propóñense medidas correctivas para reducir as emisións de formaldehído en dúas plantas nas que se observaron concentracións elevadas. Estas accións inclúen o aumento da temperatura de operación de 540 °C a 730 °C nos sistemas de redución de emisións dos fornos de imprimación, a redirección dos gases da zona de flash off de imprimación para ser tratados nos devanditos sistemas de redución, a reparación ou a substitución de pezas danadas e equipos de redución antigos para lograr unha eficiencia de destrución adecuada, e a instalación de equipos de redución de emisións nos fornos do proceso de acabado (capa de pintura base e laca clara) cuxos gases residuais emítense á atmosfera sen tratamento. Como seguinte paso, levouse a cabo unha avaliación dos impactos ambientais e económicos das diferentes accións nunha das dúas plantas de pintura afectadas. Para iso realizouse un ACV do proceso de pintado nesta planta e unha análise de ecoeficiencia das diferentes opcións para reducir o formaldehído. Os resultados obtidos na planta de pintura estudada utilizáronse para elaborar o inventario para estas análises. Ambos estudos descríbense nos capítulos 3 e 4. Capítulo 3. Análise de Ciclo de Vida O capítulo 3 ocúpase do ACV do proceso de pintado de vehículos nunha planta de pintura na que se observaron altas emisións de formaldehído. Esta avaliación realizouse para analizar os impactos ambientais do proceso e comparar estes impactos antes e despois da introdución das diferentes accións para reducir as emisións. Para levar a cabo este estudo, definíronse diferentes escenarios que se describen en detalle neste capítulo. Seguindo a definición dos escenarios, explícanse e móstranse as metodoloxías empregadas tanto para o ACV como para a elaboración do Inventario de Ciclo de Vida (ICV) necesario. Por último, examínanse os resultados da análise, o que permite comparar os distintos escenarios en relación co seu impacto ambiental. Os escenarios estudados no ACV poden resumirse da seguinte maneira: • Caso Base: representa a planta de pintura como funcionaba en 2015 antes de que se implementase calquera acción para reducir as emisións de formaldehído. • Escenario A: representa a planta de pintura en 2016 despois de que se implementou un primeiro conxunto de accións. Éstas consisten nunha redución da cantidade de Resumo 5 formaldehído libre nas pinturas e unha diminución das emisións do proceso de imprimación mediante a introdución de melloras técnicas e operativas. • Escenario B: considera a planta de pintura no Escenario A coa instalación adicional dun RTO para tratar os gases residuais dos fornos de acabado (2018). • Escenario C: é unha alternativa ao Escenario B que implica a instalación de varios oxidadores térmicos recuperativos en lugar do RTO para os gases residuais dos fornos de acabado (2018). • Escenario D: representa a planta de pintura no Escenario B coa adición dunha futura mellora. Esta mellora consiste nun tratamento completo das emisións das cabinas de aplicación da capa de pintura base. Con respecto á metodoloxía, realizouse un ACV atribucional do proceso de pintado na planta de pintura estudada desde unha perspectiva “do berce á tumba", seguindo os requisitos e directrices das normas ISO 14040:2006 e ISO 14044:2006. Para levar a cabo o ACV, realizouse unha Análise de Impacto de Ciclo de Vida (AICV) utilizando o software comercial SimaPro v.8.2 coa metodoloxía European ReCiPe Midpoint V1.12, utilizando a base de datos EcoInvent v3.2. Esta metodoloxía ten en conta 18 categorías de impacto. Para a elaboración do ICV, recompiláronse datos sobre o consumo de materiais e enerxía, así como datos de residuos e emisións correspondentes a un ano de produción, e refiríronse á unidade funcional dunha hora de funcionamento. No presente capítulo móstranse os datos de inventario recompilados para os subprocesos incluídos no estudo (cataforese, imprimación, pintura base e laca clara). Tras a selección das categorías de impacto e a clasificación dos resultados do inventario, seguíronse os pasos de caracterización e normalización definidos nas normas ISO mencionadas. A caracterización do proceso de pintado no Caso Base realizouse para identificar o subproceso con maior impacto ambiental. Ademais, realizouse a caracterización de cada un dos subprocesos para recoñecer os inputs e outputs que contribúen en maior medida ao impacto ambiental. O seguinte paso foi a caracterización do sistema para os Escenarios A, B e C, e finalmente o Escenario D. A continuación, para facilitar a comparación dos distintos escenarios, normalizáronse os resultados. Para comparar os datos normalizados, aplicáronse dous criterios diferentes na selección das categorías de impacto máis relevantes: • Todas as categorías de impacto cuxa contribución relativa ao impacto ambiental total foi superior ao 2 %. • Toxicidade humana (HT en inglés) exclusivamente. Os resultados da caracterización do proceso de pintado no Caso Base indican que o proceso de acabado (pintura base e laca clara) causa os maiores impactos ambientais de todo o proceso. Este resultado é razoable debido ao maior consumo de materiais e á produción de emisións deste subproceso, ao maior consumo de gas natural e ás emisións directas sen sistemas de redución instalados. Ademais, a cataforese tamén se identificou como un proceso cunha contribución relevante ao impacto ambiental total, principalmente debido á resina epoxi contida na pasta catiónica utilizada neste proceso. Unha vez analizado o proceso completo de pintado, avaliáronse os escenarios de mellora definidos. Os resultados de caracterización do Escenario A comparáronse cos do Caso Base. DANIEL GRANADERO REY 6 No proceso de imprimación observouse unha diminución do 7 % da categoría de impacto de toxicidade humana (HT). Por tanto, o Escenario A logra reducir a toxicidade humana mediante a redución das emisións de formaldehído. Con todo, o maior consumo de gas natural deste escenario debido ao aumento da temperatura de operación dos equipos de redución de emisións conduciu a un aumento en case todas as demais categorías de impacto. Tras a análise do Escenario A, estudáronse os Escenarios B e C. Observouse que ambas as tecnoloxías de redución avaliadas nestes escenarios lograron unha diminución da toxicidade humana debido á redución das emisións de formaldehído. Con todo, a instalación de oxidadores térmicos recuperativos (Escenario C) alcanzou unha redución da toxicidade humana máis significativa que o RTO (Escenario B). Por outra banda, os oxidadores recuperativos lograron unha mellora xeral ao considerar as categorías de impacto máis relevantes seleccionadas neste estudo, a diferenza do RTO, que produce un aumento do impacto ambiental. Estes resultados explicáronse polo maior consumo total de enerxía da tecnoloxía de oxidación térmica rexenerativa. Por tanto, a instalación dos oxidadores térmicos recuperativos é a alternativa máis sostible desde o punto de vista ambiental. Por último, analizouse o Escenario D. Este escenario non logrou unha redución da categoría de impacto de HT. A mellora da HT causada pola redución das emisións de COV e formaldehído das cabinas de aplicación da pintura base compénsase cunha deterioración debida ao aumento do consumo de gas natural. Os resultados obtidos no ACV confirmaron que todos os escenarios estudados lograron reducir a toxicidade humana se se comparan coa situación inicial da planta de pintura. Con todo, a magnitude desta redución é diferente para os diferentes escenarios. A aplicación consecutiva do Escenario A seguida do Escenario C representa a opción máis sostible desde o punto de vista do medioambiente, tanto en vista da toxicidade humana como do impacto ambiental total. Capítulo 4. Análise de Ecoeficiencia dos equipos de redución de emisións de formaldehído O aspecto económico non se incluíu na avaliación do capítulo 3. Co fin de proporcionar á empresa información adicional para a toma de decisións e seleccionar a tecnoloxía máis adecuada para a redución das emisións dos fornos de acabado, levouse a cabo unha avaliación económica e unha análise de ecoeficiencia. Estas avaliacións descríbense no capítulo 4. A metodoloxía empregada para a análise así como a interpretación dos resultados obtidos figuran no presente capítulo. En base a estes resultados, explícase e xustifícase a decisión final da empresa. En última instancia, neste capítulo preséntase unha proposta para a planta de pintura de vehículos máis ecoeficiente considerando o impacto das emisións de formaldehído. A avaliación económica e a análise de ecoeficiencia realizáronse para comparar as dúas opcións de redución das emisións dos fornos de acabado na planta de pintura estudada no capítulo 3. Na avaliación económica, recompiláronse todos os datos de custos necesarios para realizar a análise de ecoeficiencia. Estes datos inclúen os custos de instalación, funcionamento e mantemento dos dous sistemas de redución ao longo da súa vida útil. Os custos totais normalizáronse á unidade funcional para permitir a comparación entre os dous sistemas. A análise de ecoeficiencia realizouse sobre a base dos criterios prescritos na norma ISO 14045:2012. Para a análise de ecoeficiencia utilizáronse os resultados de normalización obtidos previamente no ACV. Seleccionáronse dous indicadores diferentes, que se compararon co custo total por hora: Resumo 7 • Variación do índice normalizado, expresada en porcentaxe, considerando a suma das categorías de impacto cunha contribución relativa ao impacto ambiental total superior ao 2 % nos resultados da normalización. • Variación do índice normalizado, expresado en porcentaxe, da categoría de impacto HT. Os resultados da avaliación económica figuran no presente capítulo. As diferenzas significativas nos custos totais dos dous sistemas foron explicadas. Os resultados da análise de ecoeficiencia demostran que, nos casos en que só se persegue a redución das emisións de formaldehído para garantir o cumprimento legal, xunto cunha mellora xeral da toxicidade humana, e os custos son o principal factor no proceso de toma de decisións, o RTO é a opción de redución de emisións máis favorable desde o punto de vista económico. Os custos totais para a instalación dos oxidadores térmicos recuperativos son 2.2 veces superiores aos do RTO (305.36 €/h e 136.85 €/h, respectivamente). Por tanto, a decisión da empresa de instalar un RTO nos fornos de acabado da planta de pintura estudada puideron xustificarse por estes resultados. Os resultados e coñecementos adquiridos nesta tese doutoral permiten facer unha proposta para a planta de pintura de vehículos máis ecoeficiente considerando o impacto das emisións de formaldehído. Esta proposta preséntase no capítulo 4 como resultado principal deste traballo. En particular, cando se trata da redución das emisións de formaldehído dos fornos de acabado, propúxose a instalación de oxidadores térmicos recuperativos como a mellor opción, diminuíndo á súa vez a pegada ambiental da planta de pintura. Conclusións xerais Esta tese de doutoramento industrial tiña como principais obxectivos comprender exhaustivamente as emisións de formaldehído nas plantas de pintura das fábricas de produción de vehículos desde unha perspectiva ambiental e legal, propoñer e avaliar diferentes posibilidades de redución ou eliminación destas emisións e, en última instancia, formular unha proposta para a planta de pintura de vehículos máis ecoeficiente considerando o impacto das emisións de formaldehído. Os resultados obtidos no capítulo 2 en relación coas medicións das emisións de formaldehído en seis plantas de pintura, no capítulo 3 mediante unha Análise de Ciclo de Vida e, por último, no capítulo 4 mediante a avaliación económica e a análise de ecoeficiencia, permitiron alcanzar estes obxectivos. Os resultados deste traballo proporcionan nova información aos fabricantes de vehículos e aos operadores das plantas de pintura, facilitando o proceso de toma de decisións na selección da tecnoloxía de redución de emisións de gases residuais máis adecuada e outras medidas para a redución ou eliminación das emisións de formaldehído. Neste traballo, confirmáronse o ACV e a análise de ecoeficiencia como ferramentas poderosas que poden ser aplicadas no sector industrial durante as actividades de planificación e selección para avaliar e identificar a tecnoloxía máis sostible desde o punto de vista ambiental. RESUMEN La clasificación de sustancias y mezclas se revisa y corrige continuamente en la Unión Europea para reflejar las adaptaciones al progreso técnico y científico. Por lo tanto, la clasificación de los productos químicos se actualiza periódicamente y nuevas sustancias pueden reclasificarse como peligrosas. El formaldehído fue reclasificado en 2015 como una sustancia con una categoría cancerígena más alta, recibiendo las Frases de Peligro H350, puede provocar cáncer, y el H341, sospechoso de provocar defectos genéticos. Por consiguiente, todas las industrias contempladas en la Directiva 2010/75/UE sobre las emisiones industriales sustituirán, en la medida de lo posible, el formaldehído por sustancias menos peligrosas. Además, si no pueden evitarse las emisiones de esta sustancia, debe respetarse un valor límite de emisiones significativamente más estricto de 2 mg/m3 en sus focos de emisión. Uno de los sectores industriales afectados por la reclasificación del formaldehído es la industria del automóvil, y en particular las operaciones de pintado de vehículos debido a la presencia de resinas de melamina en la composición de las pinturas. Este cambio obligó a los fabricantes de vehículos a evaluar su situación legal y aplicar medidas técnicas y operativas para reducir o eliminar las emisiones de formaldehído. El proyecto de esta tesis de doctorado industrial es parte de la investigación en curso que la empresa Opel (en adelante "la empresa") está llevando a cabo para reconocer e identificar a tiempo la reclasificación de los productos químicos utilizados en sus procesos y evaluar sus impactos ambientales y económicos. En este contexto, la empresa debía evaluar el impacto del mencionado cambio en la clasificación de peligro del formaldehído con respecto al cumplimiento de la legislación medioambiental y sus repercusiones económicas. A tal efecto, se llevó a cabo un estudio detallado en diferentes plantas de producción de vehículos. Este estudio incluyó la evaluación del cumplimiento del valor límite legal de emisión aplicable mediante mediciones de las concentraciones de formaldehído en las chimeneas de los procesos de pintado afectados, una evaluación de las posibilidades para reducir o eliminar las emisiones de formaldehído, incluyendo la sustitución de materias primas y la instalación de equipos de reducción de gases residuales, y un estudio económico de las diferentes posibilidades. Como pasos esenciales de este trabajo, se llevó a cabo un análisis de ciclo de vida (ACV) del proceso de pintado en una planta real de pintura de vehículos y un análisis de ecoeficiencia de las diferentes alternativas para reducir las emisiones de formaldehído. Los resultados y conocimientos recogidos en esta investigación permitieron presentar una propuesta sobre la planta de pintura de vehículos más ecoeficiente considerando el impacto de las emisiones de formaldehído. DANIEL GRANADERO REY 10 Esta tesis doctoral se ha dividido en varios capítulos que abordan los principales objetivos del proyecto. En las secciones siguientes se resume brevemente el contenido de cada capítulo, así como las metodologías aplicadas y los principales resultados y conclusiones obtenidos. Capítulo 1. Introducción: Marco de este trabajo El capítulo 1 es un capítulo introductorio que contextualiza el marco de esta tesis. En primer lugar, se describe la empresa en la que se llevó a cabo este trabajo. A esto le sigue una explicación del estado del arte de los procesos de pintado de vehículos, que es el resultado de una investigación bibliográfica y la visita y evaluación de las plantas de pintura sobre la base de la información proporcionada por ingenieros y operadores de la empresa. Con esta información, se introducen las plantas de pintura de la empresa y se muestran sus particularidades. Por último, se describen el problema de las emisiones de formaldehído que surge en las plantas de pintura de vehículos debido a la mencionada reclasificación y las principales opciones para reducir o eliminar las emisiones de formaldehído. La empresa Opel cuenta con diez fábricas, seis de las cuales se dedican a la producción de vehículos. El proceso de producción del vehículo se lleva a cabo en diferentes zonas donde se producen, ensamblan y pintan la mayoría de las partes del vehículo. Las cuatro áreas principales involucradas en el proceso de producción son: taller de prensas, taller de carrocerías, taller de pintura y taller de montaje final. En particular, las operaciones de pintado realizadas en el taller o planta de pintura causan los mayores impactos ambientales de todo el proceso de producción. La alta demanda de energía y recursos materiales, el consumo de agua, la generación de residuos y aguas residuales, así como la emisión a la atmósfera de compuestos orgánicos volátiles (COV) son los aspectos ambientales más significativos de los procesos de pintado. El proceso de pintado de vehículos consiste en una secuencia de procesos de inmersión, así como en la aplicación de pinturas y materiales de recubrimiento utilizando equipos de atomización. Los pasos principales en el proceso de pintado son pretratamiento, cataforesis, sellado de PVC, capa de imprimación, capa de pintura base y capa de laca clara o barniz. Las diversas capas aplicadas en estas etapas garantizan una protección a largo plazo contra la corrosión, las condiciones meteorológicas, la influencia química, etc. Las distintas capas aplicadas en la carrocería del vehículo se consiguen aplicando recubrimientos y pinturas con diferentes componentes y aditivos que les proporcionan la estabilidad, durabilidad y características visuales necesarias. En general, los componentes básicos de las pinturas son los disolventes orgánicos, el agua, las resinas, los plastificantes, los tintes y los pigmentos. Una de las resinas más usadas en las pinturas de los vehículos son las resinas de melamina, producidas por la reacción de melamina y formaldehído. Por lo tanto, el formaldehído está presente en las pinturas para automóviles como residuo asociado al proceso de fabricación de la resina, pero también como componente ligado a los polímeros de melamina. Teniendo en cuenta la presencia de formaldehído en las pinturas de los vehículos y su alta volatilidad, caben esperar emisiones de esta sustancia a la atmósfera. En este capítulo se establece la hipótesis sobre las áreas y procesos en los que pueden producirse emisiones de formaldehído. La hipótesis puede resumirse de la siguiente manera: • En primer lugar, una pequeña cantidad de formaldehído libre presente en las pinturas puede emitirse a la atmósfera a través de los gases residuales procedentes directamente de las cabinas de pintado. Resumen 11 • En segundo lugar, la estructura melamina-formaldehído se rompe durante el proceso de curado de pintura dentro de los hornos de secado a altas temperaturas, liberando formaldehído que se emitirá a la atmósfera si no se instala ningún equipo de reducción de emisiones o si el sistema de reducción no es capaz de eliminar el formaldehído. Esta hipótesis se analiza a fondo en el capítulo 2. Las seis plantas de pintura de la empresa fueron consideradas en este trabajo para la evaluación de las emisiones de formaldehído. Se llevó a cabo una evaluación exhaustiva de cada planta como etapa preparatoria para el estudio realizado en el capítulo 2. En el capítulo 1 se indican las diferentes características y condiciones de trabajo de cada planta. En cuanto a las opciones para reducir o eliminar las emisiones de formaldehído, se hace una distinción entre las emisiones de formaldehído libre de las cabinas de pintado y las emisiones de los hornos de secado. En cuanto a la primera, la purificación de las pinturas para reducir la concentración de formaldehído libre es la medida más adecuada. La opción elegida por los fabricantes de pintura fue mejorar los procesos de fabricación de la resina para eliminar las impurezas del formaldehído. Para eliminar o reducir las emisiones de formaldehído de los hornos de secado, se pueden considerar dos tecnologías alternativas. La primera opción es la instalación de un oxidador térmico regenerativo (RTO en inglés). Este equipo consta de varios lechos con relleno cerámico donde el proceso de oxidación tiene lugar en una serie de pasos alternos de calentamiento y enfriamiento. La segunda alternativa es la oxidación térmica recuperativa, que consiste en una cámara de combustión única en la que se produce la oxidación de los COV. Ambos tipos de tecnología pueden tratar todos los gases residuales de los hornos de secado y se basan en los principios de la oxidación térmica. Las características de cada tecnología se explican en el capítulo 1. Capítulo 2. Inventario de las emisiones de formaldehído En el capítulo 2 se describe la primera investigación realizada en las seis plantas de pintura de vehículos de la empresa en relación con las mediciones de las emisiones de formaldehído. En este capítulo se explican la elaboración de los programas de medición y las metodologías aplicadas para las mediciones. Posteriormente, se examinan y exponen los resultados teniendo en cuenta la hipótesis enunciada en el capítulo 1. Se identifican las plantas de pintura y los procesos que requieren medidas correctivas para garantizar el cumplimiento del valor límite de emisión aplicable y se proponen medidas específicas para la reducción de las emisiones de formaldehído. Por último, se muestran los datos de inventario de las emisiones de formaldehído utilizados para el análisis de ciclo de vida (ACV) desarrollado en el capítulo 3. Para realizar las mediciones de las concentraciones de formaldehído, se elaboraron programas de medición específicos para cada planta de pintura. Se seleccionaron e incluyeron en los programas las chimeneas pertinentes de los procesos afectados. En general, el alcance de las mediciones incluyó los gases residuales de las cabinas de pintado, las zonas de flash off y los hornos de secado de los subprocesos de cataforesis, imprimación, capa de pintura base y capa de laca clara. En casos específicos, también se incluyeron los gases residuales procedentes de operaciones menores como el sellado de PVC o la aplicación de ceras. En este capítulo se indican los puntos de medición específicos de cada planta, así como las condiciones de funcionamiento durante el muestreo. Las mediciones se llevaron a cabo por empresas de medición disponibles en la región donde se encuentra la planta de producción. Estas empresas fueron seleccionadas tras un examen preliminar que aseguró que contaran con la acreditación y los conocimientos necesarios para el DANIEL GRANADERO REY 12 muestreo y el análisis de las mediciones de las emisiones de formaldehído. Las empresas aplicaron tres metodologías diferentes (DNPH Method – Impinger Method, XAD-2 Collection Tubes Method and Multicomponent FTIR Gas Analyzer), en función de su disponibilidad y acreditación. Estas metodologías se describen en detalle en este capítulo. Los resultados de las mediciones confirman y validan la hipótesis enunciada en el capítulo 1. Las concentraciones observadas en los gases residuales de las cabinas de pintado en todas las plantas fueron típicamente inferiores a 0.5 mg/m3 y, por tanto, muy inferiores al valor límite de emisión aplicable. Esto indica que las emisiones de las cabinas no son motivo de preocupación desde el punto de vista legal. Por el contrario, las concentraciones encontradas a la salida de los hornos de secado superan significativamente el valor límite de emisión, con resultados que alcanzan 88.3 mg/m3. Los resultados también demuestran que las altas concentraciones de formaldehído después del horno pueden reducirse con éxito a valores inferiores al valor límite de emisión aplicable si se instala un equipo de reducción para tratar el gas residual del horno y éste se opera correctamente. Las dos tecnologías consideradas, es decir, la oxidación térmica regenerativa y recuperativa, pudieron reducir el formaldehído obteniendo resultados similares. Teniendo en cuenta estos resultados, se proponen medidas correctivas para reducir las emisiones de formaldehído en dos plantas en las que se observaron concentraciones elevadas. Estas acciones incluyen el aumento de la temperatura de operación de 540 °C a 730 °C en los sistemas de reducción de emisiones de los hornos de imprimación, la redirección de los gases de la zona de flash off de imprimación para ser tratados en dichos sistemas de reducción, la reparación o el reemplazo de piezas dañadas y equipos de reducción antiguos para lograr una eficiencia de destrucción adecuada, y la instalación de equipos de reducción de emisiones en los hornos del proceso de acabado (capa de pintura base y laca clara) cuyos gases residuales se emiten a la atmósfera sin tratamiento. Como siguiente paso, se llevó a cabo una evaluación de los impactos ambientales y económicos de las diferentes acciones en una de las dos plantas de pintura afectadas. Para ello se realizó un ACV del proceso de pintado en esta planta y un análisis de ecoeficiencia de las diferentes opciones para reducir el formaldehído. Los resultados obtenidos en la planta de pintura estudiada se utilizaron para elaborar el inventario para estos análisis. Ambos estudios se describen en los capítulos 3 y 4. Capítulo 3. Análisis de Ciclo de Vida El capítulo 3 se ocupa del ACV del proceso de pintado de vehículos en una planta de pintura en la que se observaron altas emisiones de formaldehído. Esta evaluación se realizó para analizar los impactos ambientales del proceso y comparar estos impactos antes y después de la introducción de las diferentes acciones para reducir las emisiones. Para llevar a cabo este estudio, se definieron diferentes escenarios que se describen en detalle en este capítulo. Siguiendo la definición de los escenarios, se explican y muestran las metodologías empleadas tanto para el ACV como para la elaboración del Inventario de Ciclo de Vida (ICV) necesario. Por último, se examinan los resultados del análisis, lo que permite comparar los distintos escenarios en relación con su impacto ambiental. Los escenarios estudiados en el ACV pueden resumirse de la siguiente manera: • Caso Base: representa la planta de pintura como funcionaba en 2015 antes de que se implementara cualquier acción para reducir las emisiones de formaldehído. Summary 19 The six paint shops of the company were considered in this work for the evaluation of the formaldehyde emissions. A thorough assessment of each paint shop was conducted as a preparation step for the study carried out in chapter 2. The different characteristics and conditions of the paint shops are shown in chapter 1. When it comes to the options to reduce or eliminate formaldehyde emissions, a distinction is made between the emissions of free formaldehyde from the paint booths and the emissions from the ovens. Concerning the first, the purification of the paints to reduce the concentration of free formaldehyde is the most suitable countermeasure. An improvement of the manufacturing processes of the resin to eliminate impurities of formaldehyde was the most preferable option selected by the paint manufacturers. To eliminate or reduce formaldehyde emissions from the drying ovens, two alternative technologies can be considered. The first option is the installation of a regenerative thermal oxidizer (RTO). This equipment comprises several beds filled with ceramic medium where the oxidation process takes place in a series of alternative heating and cooling steps. The second alternative is the recuperative thermal oxidation, which consists of a single combustion chamber where the VOCs are oxidized. Both types of technology can treat all waste gases from the ovens and are based on the principles of thermal oxidation. The characteristics of each technology are explained in chapter 1. Chapter 2. Inventory of formaldehyde emissions Chapter 2 describes the first main investigation performed at the six vehicle paint shops of the company regarding the formaldehyde emissions measurements. In this chapter, the elaboration of the measurement programs as well as the methodologies applied for the measurements are explained. Subsequently, a discussion of the results is provided in view of the hypothesis stated in chapter 1. The paint shops and processes that need corrective action to ensure compliance with the applicable emission limit value are identified and specific actions for the reduction of the formaldehyde emissions are proposed. Finally, the inventory data of formaldehyde emissions used as input for the Life Cycle Assessment (LCA) developed in chapter 3 is shown. To carry out the measurements of formaldehyde concentrations, measurement programs were specifically developed for each paint shop. The relevant chimneys of the affected processes were selected and included in the programs. In general, the scope of the measurements included the waste gas from the booths, flash off zones and drying ovens of the electrocoating, primer, basecoat and clearcoat sub-processes. In specific cases, the waste gas from minor operations such as PVC-sealing or waxing were also included. The specific measurement points for each paint shop as well as the operating conditions during the sampling are shown in this chapter. The measurements were conducted by measuring companies available in the region where the production plant is located. These companies were selected after a preliminary screening ensuring that they had the necessary accreditation and expertise in the sampling and analysis of emissions measurements of formaldehyde. Three different methodologies, i.e. DNPH Method – Impinger Method, XAD-2 Collection Tubes Method and Multicomponent FTIR Gas Analyzer, were applied by the companies depending on their availability and accreditation. These methodologies are described in detail in this chapter. The results of the measurements confirm and validate the hypothesis stated in chapter 1. The concentrations observed at the waste gas from the spray booths in all paint shops were typically below 0.5 mg/m3 and thus well below the applicable emission limit value. This DANIEL GRANADERO REY 20 indicates that the emissions from the spray booths are not a concern from the legal perspective. On the contrary, the concentrations found at the exit of the drying ovens significantly exceed the emission limit value, with results that reach 88.3 mg/m3. The results also demonstrate that the high concentrations of formaldehyde after the oven can be successfully reduced to values below the applicable emission limit value if abatement equipment is installed to treat the waste gas from the oven and it is properly operated. The two considered technologies, i.e. regenerative and recuperative thermal oxidizers, were able to reduce formaldehyde achieving similar results. Considering these results, proposals for actions to reduce the formaldehyde emissions are made for two paint shops where high concentrations were observed. These actions include the increase of the abatement temperature from 540 °C to 730 °C in the primer oven abatement systems, the redirection of the primer flash off waste gas to be treated in these abatement installations, the repair or exchange of damaged parts and old abatement equipment to achieve a proper destruction efficiency, and the installation of abatement equipment at the topcoat ovens whose waste gas was emitted to the atmosphere without treatment. As a next step, an evaluation of the environmental and economic impacts of the different actions for one of the two affected paint shops was carried out. For this purpose, a LCA of the painting process in this paint shop and an eco-efficiency analysis of the different options to reduce formaldehyde were performed. The measurement results obtained in the paint shop of study were used as input to elaborate the inventory for these assessments. These studies are described in chapters 3 and 4. Chapter 3. Life Cycle Assessment Chapter 3 deals with the LCA of the vehicle painting process of one affected paint shop where high formaldehyde emissions were observed. This assessment was performed to analyze the environmental impacts of the process and to compare these impacts before and after the introduction of the different actions to reduce the emissions. To carry out this study, different scenarios were defined. They are described in detail in this chapter. Following the definition of the scenarios, the methodology applied for the LCA as well as the elaboration of the necessary Life Cycle Inventory (LCI) are explained and shown. Finally, the results of the assessment are discussed, allowing the comparison of the different scenarios in view of their environmental impact. The scenarios studied in the LCA can be summarized as follows: • Base Case: it represents the paint shop as it was operating in 2015 before any action was implemented to reduce the formaldehyde emissions. • Scenario A: it represents the paint shop in 2016 after a first set of actions was implemented. These consist of a reduction of the amount of free formaldehyde in the paints and a decrease of the emissions from the primer process by introducing technical and operational improvements. • Scenario B: it considers the paint shop in Scenario A with the additional installation of an RTO to treat the waste gas from the topcoat ovens (2018). • Scenario C: it is an alternative to scenario B which involves the installation of several recuperative thermal oxidizers instead of the RTO for the topcoat ovens waste gas (2018). Summary 21 • Scenario D: it represents the paint shop in scenario B with the addition of one future improvement. This improvement consists of a complete treatment of the emissions from the basecoat spray booths. With regard to the methodology, an attributional LCA of the painting process in the paint shop studied was performed from a “cradle-to-grave” perspective following the requirements and guidelines of the ISO 14040:2006 and ISO 14044:2006. To carry out the LCA, a Life Cycle Impact Assessment (LCIA) was conducted using commercial software SimaPro v.8.2 with the European ReCiPe Midpoint V1.12 methodology, using the EcoInvent v3.2 database. This methodology considers 18 impact categories. For the elaboration of the LCI, material and energy consumption data as well as the waste and emissions data were collected for one year of production and they refer to the functional unit of 1 hour of operation. The inventory data collected for the sub-processes within scope (electrocoating, primer and topcoat) are shown in this chapter. After the selection of the impact categories and the classification of the inventory results, the characterization and normalization steps defined in the mentioned ISO standards were followed. The characterization of the painting process in the Base Case was performed to identify the sub-process with the greatest environmental impact. In addition, a characterization of each individual sub-process was conducted to obtain the inputs and outputs with the highest contribution to the environmental impact. The next step was the characterization of the system for the Scenarios A, B and C, and finally Scenario D. As a subsequent step to facilitate the comparison of the different scenarios, the normalization of the results was performed. To compare the normalized data, two different criteria were applied to select the most relevant impact categories: • All impact categories whose relevant contribution to the total environmental impact was higher than 2 %. • Human toxicity (HT) exclusively. The characterization results of the painting process in the Base Case indicate that the topcoat process causes the highest environmental impacts of the whole painting process. This result is reasonable due to the higher consumption of materials and production of emissions of this sub-process, the higher consumption of natural gas, and the direct emissions without installed abatement systems. Moreover, the electrocoating was also identified as a process with a relevant contribution to the total environmental impact, mainly due to the epoxy resin contained in the cationic paste used in this process. Once the overall painting process was analyzed, the defined improvement scenarios were evaluated. The characterization results of Scenario A were compared to those of the Base Case. A decrease of 7 % of the human toxicity (HT) impact category was observed in the primer process. Therefore, Scenario A achieves the pursued reduction of the human toxicity through the formaldehyde emissions reduction. However, the higher natural gas consumption of this scenario due to the increase of the abatement temperature led to an increase in almost all other impact categories. Following the analysis of Scenario A, Scenarios B and C were studied. It was observed that both abatement technologies evaluated in these scenarios achieved a decrease in the human toxicity due to the reduction of formaldehyde emissions. However, the implementation of recuperative thermal oxidizers (Scenario C) reached a more significant human toxicity DANIEL GRANADERO REY 22 reduction than the RTO (Scenario B). On the other hand, the recuperative oxidizers achieved an overall improvement when considering the most relevant impact categories selected in this study, unlike the RTO, which yields an increase of the environmental impact. These results were explained by the higher overall energy consumption of the regenerative thermal oxidation technology. Thus, the installation of the recuperative thermal oxidizers is the most environmentally sustainable alternative. Finally, Scenario D was analyzed. This scenario did not achieve a reduction of the HT impact category. The improvement in the HT caused by the reduction of VOC and formaldehyde emissions from the basecoat spray booths is compensated by a deterioration due to the increase of the natural gas consumption. The results obtained in the LCA confirmed that all studied scenarios achieve the pursued reduction of the human toxicity if they are compared to the original situation of the paint shop. However, the magnitude of this reduction is different for the different scenarios. The subsequent implementation of Scenario A followed by Scenario C represents the most environmentally sustainable option in view of both human toxicity and the total environmental impact. Chapter 4. Eco-efficiency analysis of abatement equipment for formaldehyde emissions reduction The economic aspect has not been included in the evaluation of chapter 3. In order to provide the company with additional input for the decision-making and select the most suitable technology for the abatement of the topcoat oven emissions, an economic evaluation and an eco-efficiency analysis were conducted. These assessments are described in chapter 4. The methodology used for the analysis as well as a discussion of the results is provided in this chapter. Furthermore, the final decision of the company considering all the results obtained in this work is explained and justified. Ultimately, in this chapter a proposal for the best ecoefficient paint shop in view of formaldehyde emissions performance is given. The economic evaluation and eco-efficiency analysis were performed to compare the two abatement options for the topcoat ovens emissions of the paint shop studied in chapter 3. For the economic evaluation, all cost data necessary to carry out the eco-efficiency analysis were collected. These data include installation, operational and maintenance costs of the two abatement systems over their lifetime. The total costs were normalized to the functional unit to allow the comparison between the two systems. The eco-efficiency analysis was conducted based on the criteria prescribed in the ISO 14045:2012. For the eco-efficiency analysis, the normalization results previously obtained in the LCA were used. Two different indicators were selected and represented against the total cost per hour: • Variation of the normalized index, expressed in percentage, considering the sum of the impact categories with a relevant contribution to the total environmental impact greater than 2 % in the normalization results. • Variation of the normalized index, expressed in percentage, of the HT impact category. The results of the economic assessment are shown in this chapter. Significant differences in the total costs of the two systems were observed and explained. The results of the eco-efficiency analysis demonstrate that in cases where only the reduction of the formaldehyde emissions to ensure legal compliance along with an overall improvement of the human toxicity are pursued and the costs are the main factor in the decision-making process, the RTO is the Summary 23 most economically favorable abatement option. The total costs for the implementation of the recuperative thermal oxidizers were 2.2 times those of the RTO (305.36 €/h and 136.85 €/h, respectively). Thus, the decision of the company to install an RTO at the topcoat ovens of the studied paint shop could be justified by these results. The results and knowledge acquired in this Ph.D. thesis allow to make a proposal for the best eco-efficient paint shop in view of formaldehyde emissions performance. This proposal is made in chapter 4 as the main outcome of this work. In particular, when it comes to the reduction of the formaldehyde emissions from the topcoat ovens, the installation of recuperative thermal oxidizers was proposed as the best option to reduce the emissions decreasing the environmental footprint of the paint shop. General Conclusions This industrial Ph.D. thesis had the main objectives to gain a deep understanding of the formaldehyde emissions in paint shops of vehicle manufacturing plants from both an environmental and a legal compliance perspective, to propose and evaluate different possibilities for the reduction or elimination of these emissions, and ultimately, to formulate a proposal for the best eco-efficient paint shop in view of formaldehyde emissions performance. The results obtained in chapter 2 regarding the formaldehyde emissions measurements at six vehicle paint shops, in chapter 3 by means of a Life Cycle Assessment, and finally in chapter 4 through the economic evaluation and the eco-efficiency analysis, made possible to achieve these objectives. The outcomes of this work provide new information to vehicle manufacturers and paint shop operators, facilitating the decision-making process in the selection of the most suitable abatement technology and further actions for the reduction of formaldehyde emissions. LCA and eco-efficiency analysis have been confirmed as powerful tools that can be applied during the planning and selection activities to evaluate and identify the most environmentally sustainable technology. OBJECTIVES AND MOTIVATION OF THIS WORK The project of this industrial Ph.D. thesis is part of the ongoing investigation that the company Opel (hereinafter referred to as “the company”) is conducting to timely recognize and identify the reclassification of chemicals used in its processes, in particular in processes associated with painting operations in vehicle assembly plants, and evaluate the environmental and economic impact of such reclassifications. With one of the latest legal changes with regard to classification of hazardous substances, formaldehyde was reclassified to receive the hazard statements H350, may cause cancer, and H341, suspected of causing genetic defects. With this higher cancer-causing classification, the obligations on the substitution of hazardous substances and control of emissions established by European legislation are immediately applicable. The company needs to evaluate the impact of the mentioned reclassification of formaldehyde on its environmental legal compliance and the economic repercussions. A detailed study is required at different vehicle production plants to assess the impact of the reclassification. This study includes the evaluation of compliance with air emission limit values through measurements of formaldehyde concentrations at the relevant chimneys from the affected painting processes, an evaluation of possibilities to reduce or eliminate the emissions of formaldehyde including raw material substitution and installation of waste gas cleaning devices, and an economic study of the different possibilities. As an essential part of this work, a Life Cycle Assessment (LCA) of the painting process in a real vehicle paint shop and an eco-efficiency analysis of different options to reduce formaldehyde emissions were carried out in order to define the most eco-efficient paint shop in view of formaldehyde emissions performance. This industrial Ph.D. thesis has been divided in several stages aiming to address the main objectives of the project. The main objectives can be summarized as follows: • Evaluation of the state-of-the-art technologies for the vehicle painting processes and environmental control equipment supported by bibliographic research. • Understanding the formaldehyde emissions in vehicle paint shops from both an environmental and a legal compliance perspective. DANIEL GRANADERO REY 26 • Evaluation of the different possibilities to reduce or eliminate the emissions of formaldehyde. • Economic assessment of the control equipment for formaldehyde emissions reduction. • Life Cycle Assessment (LCA) and eco-efficiency analysis to determine the most sustainable option to reduce formaldehyde emissions. • Formulate a proposal for the best eco-efficient paint shop in view of formaldehyde emission performance. In chapter 1, the framework of this work is presented, including the description of the company, the production plants and the paint shops of study. Moreover, an explanation of the current vehicle painting processes is given as a result of the bibliographic research and the visit and evaluation of the paint shops based on information provided by paint shop engineers and operators. Finally, a detailed description of the formaldehyde emissions problem as well as an explanation of the main options to reduce or eliminate the emissions of formaldehyde is given. In chapter 2, the first main investigation conducted in the paint shops of study is carried out. Measurements of formaldehyde emissions were performed at six paint shops to evaluate the main sources of formaldehyde and the legal compliance situation with and without VOC emissions control equipment, and to propose possible corrective actions in emission sources with high concentrations of formaldehyde. In chapter 3, the Life Cycle Assessment (LCA) is performed to analyze the environmental impacts of one of the six paint shops before and after the introduction of different countermeasures to reduce formaldehyde emissions. For the collection of inventory data, real data from the paint shop of study was used, including the results of the formaldehyde measurements carried out previously, as shown in chapter 2. Chapter 4 deals with the economic and eco-efficiency analysis of the two different control equipment technologies studied for the reduction of the formaldehyde emissions. Real monetary data from equipment manufacturers and paint shop engineers and operators were used to carry out this evaluation. Ultimately, a proposal is made for the best eco-efficient paint shop considering the reduction of formaldehyde emissions as a priority, taking into account the results of the eco-efficiency analysis as well as the Life Cycle Assessment. This chapter partially reproduces content already published as “Granadero, D. a b, Garcia-Muñoz, A. b, Adam, R. b, Omil, F. a and Feijoo, G. a, 2023. Evaluation of abatement options to reduce formaldehyde emissions in vehicle assembly paint shops using the Life Cycle methodology. Cleaner Environmental Systems, 11, 100139. ISSN 2666-7894, https://doi.org/10.1016/j.cesys.2023.100139. a CRETUS, Department of Chemical Engineering, School of Engineering, Universidade de Santiago de Compostela, 15782, Santiago de Compostela, Spain b Environmental Compliance and Sustainability, Stellantis, 65423, Rüsselsheim am Main, Germany More information on the Publications section at the end of this Ph.D. thesis. 1 INTRODUCTION: FRAMEWORK OF THIS WORK Vehicle manufacturing is one of the most complex industrial manufacturing processes because it requires large spaces as well as the sequential and coordinated operation of multiple technologies (Bysko et al., 2020; Giampieri et al., 2022). Painting operations have been identified as the stages with the greatest environmental impacts of the entire production process (VDI guideline 3455:2013-08; Onofre et al., 2020). The high demand for energy and resources, such as natural gas and raw materials for the production of coatings and paints, water consumption along with the generation of waste and wastewater are the most significant environmental aspects associated with the painting operations of vehicle assembly plants (STS BREF, 2020). In particular, when it comes to identifying the most polluting compounds in this type of facility, the environmental impact is marked by the emission of volatile organic compounds (VOCs), which represent the most relevant direct emissions. They are derived from spray booths, drying ovens and cleaning of equipment with organic solvents (Rivera and Reyes- Carrillo, 2014; Rivera and Reyes-Carrillo, 2016; Ou et al., 2022). The European Union (EU) car manufacturers emitted in 2021 an average of 2.2 kg/car and a total of 25.7 thousand tons of VOCs due to their vehicle painting activities (ACEA, 2022), which corresponds to 2.5 % of the total VOCs emitted in Europe (German Environment Agency, 2023). An exhaustive analysis of the paints and coatings used in a vehicle painting plant allows the identification of complex mixtures formulated from numerous components (Akafuah et al., 2016). In general, organic solvents, water, resins, plasticizers, dyes and pigments are the basic components of paints, being the binder (i.e. the resins) the predominant constituent defining the paint´s characteristics (McMahon et al., 2023). Additionally, new developments in automotive paints include the use of nanoparticles as fillers (Nayane de Queiroz et al., 2022). The solvent content of color basecoats is in the range of 12-17 % in water-based and 55-82 % in solventbased paints, while clearcoats typically have a solvent content up to 50 % (STS BREF, 2020). One of the most commonly used binding agents in industrial coatings are amino resins and, mainly, those derived from melamine (Pizzi and Ibeh, 2022). Melamine resins used in automotive coatings are produced by the reaction of melamine and formaldehyde (Poth, 2008). DANIEL GRANADERO REY 28 Paint manufacturers indicate melamine resin contents varying from 0.1 % to 18 %, depending on the type of coating. Other amino resins used in coatings, such as those derived from urea or (meth)acrylamide, are also obtained by the reaction of different chemicals with formaldehyde (Pizzi and Ibeh, 2022). Thus, formaldehyde is present in automotive coatings as a residue associated with the resin manufacturing process (with a concentration below 0.1 %, as indicated in Safety Datasheets) but also as a component bound in melamine polymers. Concerning the identification of formaldehyde sources, the emission of small quantities of this compound into the atmosphere present in the exhaust gas flow of the spray booth has been quantified at very low levels (Kim et al., 2011). However, also the bound formaldehyde from melamine resins is released from inside the drying chambers, which operate at elevated temperatures (Salthammer et al., 2010; Salthammer, 2019); therefore, depending on the configuration of the coating line and the efficiency of the end-of-process abatement equipment connected to the drying ovens, the formaldehyde emission can be significant (Sorrels et al., 2017). At present, not all vehicle painting facilities located in Europe have abatement equipment installed in the drying ovens (STS BREF, 2020). This depends on the specific legal requirements of each country, their specific set-up and the subsequent retrofitting steps from the plant assembly to the present time. Besides, the use of abatement equipment can be related to the type of paints used in the paint shop. For instance, in 2016, 43 % of the EU paint shops were estimated to apply solvent-based primer or basecoats, or a combination of both. This type of paint shops are more likely to have air emissions abatement equipment (STS BREF, 2020). In 2015, formaldehyde was reclassified as a substance with carcinogenic potential (category 1B) and mutagenic potential (category 2) in the amendments to the so-called CLP Regulation on classification, labelling and packaging of substances and mixtures (Regulation (EC) No 1272/2008; Regulation (EU) No 605/2014; Regulation (EU) No 2015/491). With this change, all EU industries affected by the Industrial Emissions Directive 2010/75/EU shall, as far as possible, replace formaldehyde with less harmful substances. If formaldehyde emissions cannot be avoided, what is the case for painting operations in the automotive industry due to the use of the melamine resins, operators need to cope with significantly more stringent Emission Limit Values (Directive 2010/75/EU). Different technologies are available for the removal of VOCs from exhaust gases. These include biological treatment, recuperative thermal oxidation, regenerative thermal oxidation and catalytic oxidation (Mulholland and Dyer, 1999; Berenjian et al., 2012; Tomatis et al., 2019; Li et al., 2023). In the automotive industry, for the treatment of VOCs in vehicle paint shops, regenerative thermal oxidation and recuperative thermal oxidation, the latter sometimes in combination with catalytic oxidation, have been commonly applied (VDI guideline 3455:2013 08; STS BREF, 2020). Recuperative thermal oxidizers consist of a single combustion chamber where the VOCs are oxidized. On the other hand, regenerative thermal oxidizers comprise several beds filled with ceramic medium where the oxidation process takes place in a series of alternative heating and cooling steps. Both technologies have proven to be efficient in VOC destruction with efficiencies higher than 95 % (STS BREF, 2020). The introduction of catalytic oxidation to recuperative oxidizers allowed the reduction of the high operating temperatures from 700 °C–740 °C to 400 °C necessary to obtain the desired abatement efficiency, with the consequent reduction in natural gas consumption (Yang et al., 2019; STS BREF, 2020; Brummer et al., 2022). However, this technique is not in use in vehicle paint shops because of the high maintenance requirements of the catalyst (STS BREF, 2020). Introduction: Framework of this work 35 Figure 4. Multilayer coating of cars (Streitberger and Dössel, 2008). These layers are achieved by applying coatings and paints with a set of components and additives that provide them with the necessary stability, durability and visual characteristics. The main components of paints are (Stoye, 1993; Stoye and Freitag, 1998; Wicks et al., 2007; McMahon et al., 2023): • Binders or resins: The binder (i.e. resins) is the predominant constituent defining the paint´s characteristics. Binders provide adherence and resistance against mechanical and chemical strain. Amino resins derived from melamine are the most used resins in the automotive industry. These resins are made by the reaction of melamine, and formaldehyde (Poth, 2008). • Pigments: They provide color, opacity and usually improve the resistance against corrosion. The clearcoat paint is the only paint without pigment. • Additives: They improve aspect, biological properties, conservation, etc., protects against transport, and prevent defects in the coating such as bubbles, poor levelling or flocculation. Different additives are used depending on the requirements of the paints. • Fluidizing medium. Depending on the chosen fluidizing medium the paints can be waterborne or solvent borne. Additionally, a different kind of paints based on a powder system is also available, however this system is typically not applied in European paint shops. All paints contain different quantities of solvents in their composition. 1.3 THE PAINT SHOPS OF STUDY All paint shops of the company´s six vehicle manufacturing plants were considered for the evaluation of the formaldehyde emissions in the framework of this study. In order to develop the measurement program, a comprehensive study was necessary to identify and understand the particularities of each paint shop. While the painting steps are the same for the six paint shops and follow the sequence explained in this chapter, each paint shop has different conditions which need to be considered. Two paint shops use solvent-based basecoat paints and four use waterborne basecoat paints; four paint shops collect almost all their waste gas streams from the spray booths and discharge them through one chimney to the atmosphere, whereas the other two paint shops have individual chimneys for each sub-process or painting booth. Another significant difference can be observed in their VOC emissions control technology implemented. Table 1 shows a summary of the main conditions identified in the six paint shops, which was elaborated from a data collection exercise consisting of information provided by paint shop operators. Table 1. Collection of paint shop conditions – survey data. Section affected by copyright protection. DANIEL GRANADERO REY 36 Whereas: Product: • PC: Passenger car • LCV: Light Commercial Vehicle SOP: Start of production Subst. Change: Last substantial change carried out in the paint shop, e.g. change in technology from solvent based basecoat to waterborne basecoat, installation of new VOC abatement equipment, retrofit of painting application devices: automatization. PT-EC: Pretreatment and Electrocoating SD: Sealing and dumping PR: Primer application TC: Topcoat application (Basecoat + Clearcoat) Other: Additional lines, e.g. special vehicles, repair lines JPH: Job per hour, number of vehicles painted in one hour of production PT: Pretreatment EC: Electrocoating BC: Basecoat CC: Clearcoat CP: Cavity preservation (wax) PHO: Phosphating SB'1k: Solvent based one-component WB: Water based coating SB: Solvent based coating Recup.: Recuperative Thermal Oxidizer RTO: Regenerative Thermal Oxidizer All the information summarized in Table 1 constitute the basis for the elaboration of the measurement programs for formaldehyde emissions as described in chapter 2. Introduction: Framework of this work 37 1.4 THE FORMALDEHYDE EMISSIONS PROBLEM Formaldehyde (Verbände-Positionspapier, 2014) is a simple organic volatile compound with the chemical formula H-CHO. Formaldehyde is a colorless gaseous substance that has a typical pungent odor that can be perceived even at very low concentrations. All organic life forms produce formaldehyde that is emitted to the environment. In the human body, formaldehyde is synthesized as part of natural metabolism, a portion of which is exhaled in the air we breathe (0.001 to 0.01 mg/m3). Large amounts of formaldehyde are also emitted by forests, for example. It is formed during the photochemical decomposition of organic substances in the air and during all incomplete combustion processes. Formaldehyde has a wide range of industrial applications. It is produced synthetically on a large scale and is widely used as intermediate and end product. At the time this work was started, around 21 million metric tons were produced worldwide each year. This germicidal, preservative and disinfectant substance is contained in numerous everyday products, for example in disinfectants, household cleaners, cosmetics, various paints and varnishes, and in building products. Many industries, such as the automotive industry, chemical industry, ceramic industry, foundries, plaster industry, wood industry, paint manufacturing industry and textile industry, either directly utilize formaldehyde in their production or supporting processes or formaldehyde emissions occur due to decomposition or incomplete combustion processes (ACEA, 2014; Formacare, 2014; Verbände-Positionspapier, 2014). In the automotive industry, formaldehyde has many different applications which vary from the use of formaldehyde-based resins in fuel pumps, transmission parts and brake pads, to other applications such as decorative laminates of car interiors, engine lubricants, vulcanized rubber tyres and lightweight polyurethane foams for automobile door insulation (Formacare, 2014). In the last years, almost 9 % of the total formaldehyde production in Europe was melamine formaldehyde resins. These resins are fast-curing and can resist high temperatures and chemical damages so that they are usually used in the composition of surface coatings of vehicles (Formacare, 2014; Roth and Rupp, 2014; Bolt et al., 2016). In the vehicle manufacturing plants, the problem with formaldehyde emissions arises in the paint shops due to the use of melamine formaldehyde resins in the paints. 1.4.1 Formaldehyde in vehicle paints As explained above, the binder is one of the essential constituents of the paints used in vehicle painting. The most extended binders are melamine formaldehyde resins due to its chemical properties (Formacare, 2014; Roth and Rupp, 2014; Bolt et al., 2016; Pizzi and Ibeh, 2022) that guarantee UV resistance and shock resistance. In the melamine formaldehyde resins, formaldehyde is part of the polymer, in which it forms chemical bonds with melamine (Figure 5). It functions as a chemical protective group which ensures that no unwanted chemical reaction between melamine molecules takes place during paint application (undesired polymerization) (ACEA, 2014). DANIEL GRANADERO REY 38 Figure 5. Chemical representation of melamine formaldehyde resin production. The exact amounts of melamine formaldehyde resin and free formaldehyde in paints is usually not provided by the paint manufacturers if it does not exceed the legal thresholds which oblige them to disclose this information in the Material Safety Datasheets of the paints (Regulation (EC) No 1907/2006). Nevertheless, representative values have been provided by a paint manufacturer in the framework of this study and were collected for the inventory data necessary to carry out the Life Cycle Assessment (see chapter 3). The concentration ranges for the different paints are shown in Table 2. Table 2. Typical formaldehyde concentrations in vehicle paints. Paint type Melamine resin* in paint wt. % Electrocoating 0 Primer surface 0.5 – 7 SB basecoats 0.5 – 10 WB basecoats 0.1 – 9 Clearcoats 10 – 16 * Melamine resins contain between 0.2 and 2.8 % of free formaldehyde. Formaldehyde concentration in paints with melamine resins is generally < 0.3 wt.% According to this information, formaldehyde is present in automotive coatings as a residue associated with the resin manufacturing process but also as a component bound in melamine polymers. 1.4.2 The formaldehyde emissions Considering the presence of formaldehyde in vehicle paints and its high volatility, releases of this substance into the atmosphere can be expected. Mainly, emissions of formaldehyde can occur in two different ways: • Firstly, a small percentage of free formaldehyde present in the paints can be emitted to the atmosphere through the exhaust air coming directly from the paint booths. Based on the concentrations of melamine formaldehyde resins in the different coating steps applied, emissions of formaldehyde can be expected from primer, basecoat and clearcoat spray booths. • Secondly, during the paint curing process inside the drying ovens at high temperatures the melamine-formaldehyde structure is broken, releasing formaldehyde which will be emitted to the atmosphere if no air emissions abatement equipment is installed or if the Melamine Formaldehyde Melamine formaldehyde resin Introduction: Framework of this work 39 abatement system is not able to completely eliminate the formaldehyde (Salthammer et al., 2010; Salthammer, 2019). Figure 6 represents this hypothesis: Figure 6. Simple representation of formaldehyde emission sources in paint shop. Formaldehyde concentrations in the range from 0.2 mg/m3 to 19 mg/m3 were observed in internal measurement campaigns conducted in paint shops of different car manufacturers located in Germany (VDA, 2015). However, the emissions of formaldehyde from vehicle paint shops have not been comprehensively studied yet as the absence of publications in this field suggests. The hypothesis represented in Figure 6 was analyzed in-depth in this work and constitutes one of the main objectives and parts of this Ph.D. thesis. This study is developed in chapter 2. 1.4.3 Applicable legislation The Regulation (EC) No 1272/2008 of the European Parliament and of the Council on “classification, labelling and packaging of substances and mixtures” (so called CLP Regulation) has the main purpose to ensure a high level of protection of human health and the environment by harmonizing the criteria for classification of substances and mixtures, and the rules on labelling and packaging for hazardous substances and mixtures. To reflect the adaptions to technical and scientific progress, this regulation needs to be constantly revised and corrected, thus the classification of chemicals is regularly updated, and new substances can be reclassified as hazardous. Furthermore, the Directive 2010/75/EU on industrial emissions (so called Industrial Emissions Directive) establishes the rules of integrated pollution prevention and control from industrial activities and is applicable to the industrial processes associated with vehicle painting. This Directive requires the operators to replace, as far as possible, hazardous substances with less harmful substances. In addition, it sets Emission Limit Values (ELV) for carcinogens, mutagens, or substances toxic to reproduction. In one of the Adaptions to Technical Progress of the CLP Regulation in 2015 (Regulation (EU) No 605/2014; Regulation (EU) No 2015/491), formaldehyde was reclassified to receive the Hazard Statements H350, may cause cancer, and H341, suspected of causing genetic defects. Owing to this higher cancer-causing classification, operators shall replace formaldehyde with less harmful substances and, if the emissions cannot be avoided, compliance with a more stringent ELV of 2 mg/m3 must be guaranteed. This change forces vehicle DANIEL GRANADERO REY 40 manufacturers to evaluate their legal situation and to implement technical and operational countermeasures to reduce or eliminate formaldehyde emissions. 1.4.4 Options for formaldehyde emissions reduction 1.4.4.1 Free formaldehyde from spray booths For the elimination or reduction of formaldehyde emissions, different alternatives can be taken into account. The first and most sustainable option is the substitution of this substance in the paints and other coating materials. As part of this work, workshops and discussions with paint manufacturers were conducted in order to identify possibilities for the substitution. Concerning the elimination of the emissions of free formaldehyde from the spray booths, the purification of the paints to reduce the concentration of free formaldehyde is the most suitable countermeasure. Considering that free formaldehyde is present in the paints due to its content of melamine formaldehyde resins, an improvement of the manufacturing processes of the resin to eliminate impurities of formaldehyde is the most preferable option selected by the paint manufacturers. On the other hand, the substitution of the melamine resins in the paint is a much more complex and time-consuming project which implies years of research. This option is currently not possible as indicated by paint manufacturers. A comparison of the paints´ composition disclosed in the Material Safety Datasheet before and after the reclassification of formaldehyde (Regulation (EU) No 605/2014; Regulation (EU) No 2015/491) demonstrates that the paint manufacturers reduced the amounts of free formaldehyde in their paints due to the reclassification. In Figure 7, an example of the MSDS of a paint before the formaldehyde reclassification (Hazardous Statement: H351) is shown. The MSDS of similar paints analyzed after the reclassification of formaldehyde (Hazardous Statement: H350 and H341) did not show the presence of this substance, demonstrating that the paint manufacturer reduced its concentration below 0.1 % in weight and thus avoiding its disclosure in the MSDS. Section affected by copyright protection. Figure 7. Example of a Material Safety Datasheet from a paint with free formaldehyde in its composition. Introduction: Framework of this work 41 1.4.4.2 Formaldehyde released from drying ovens In order to eliminate or reduce formaldehyde emissions from the drying ovens, two alternative technologies can be considered, which correspond to the abatement technologies commonly installed in the vehicle paint shops across the world for the elimination of VOC emissions. The first option is the installation of a regenerative thermal oxidizer (RTO). The second alternative is the recuperative thermal oxidation. Both types of technology can treat all waste gases from the ovens and are based on the principles of thermal oxidation. The main component of a thermal oxidizer is a nozzle-stabilized flame maintained by a combination of auxiliary fuel (usually natural gas), waste gas compounds, and supplemental air added when necessary. When the waste gas passes through the flame, it is heated from its inlet temperature (≈100 °C as it leaves the ovens) to its ignition temperature, which depends on the composition of the waste gas. Thus, any organic/air mixture will ignite if its temperature is raised to a sufficiently high level. The mixture continues to react as it flows through the combustion chamber (Sorrels et al., 2017). Not only the temperature determines the efficiency of the oxidation, but also the time the waste gas takes to pass through the combustion chamber (residence time) plays an important role in the oxidation process. The shorter the residence time, the higher the reactor temperature must be to achieve a certain level of efficiency. For instance, a destruction efficiency of 95 % for toluene can be achieved at 732.8 °C with 0.5 seconds of residence time. If the residence time is increased to one second, the same efficiency could be achieved with a lower temperature of 713.9 °C. To achieve a 99 % destruction efficiency with a residence time of 0.5 seconds, the operating temperature would have to be increased to 744.4 °C. The nominal residence time is defined as the volume of the combustion chamber divided by the volumetric flow rate of the gas. Most commercial units are designed for no more than 1 second of residence time with typical combustion temperatures of 650 °C to 1100 °C. Once the unit is designed and installed, the residence time is not easily changed. Therefore, the temperature is typically the parameter that the operator sets up depending on the composition of the waste gas and the required destruction efficiency (Sorrels et al., 2017). The use of thermal oxidation for the elimination of VOC emissions leads to environmental cross-media effects (STS BREF, 2020). Apart from the natural gas necessary to operate the equipment, noise and emissions of CO, CO2 and NOx occur. Figure 8 shows the trend line of CO, total carbon (VOCs) and NOx emitted from a thermal oxidizer in relation to the operating temperature of the combustion chamber. Formaldehyde emissions can be related to the total carbon emissions. DANIEL GRANADERO REY 42 Figure 8. Trend line of CO, total carbon and NOx in relation to the temperature of the combustion chamber inside of a thermal oxidizer. Adapted data from VDI guideline 3455:2013-08. This illustration was elaborated for a simple thermal oxidizer and the temperature values vary for the different technologies described in this work. While CO follows the same trend as total carbon (VOCs), NOx has an opposite behavior. The higher the temperature of the combustion chamber, the lower the amount of CO and total carbon emitted. On the contrary, the emissions of NOx increase when the temperature raises. The green square in Figure 8 illustrates the temperature range in which the emissions of the three pollutants remain in their lowest values and represents the ideal temperature conditions to achieve a proper VOC destruction with a right balance between ensuring legal compliance and cost efficiency. 1.4.4.2.1 Regenerative Thermal Oxidation In regenerative thermal oxidation, organic solvents are oxidized at a temperature between 800°C and 850°C (VDI guideline 3455:2013-08). The inlet gas to be treated enters a first hot bed filled with ceramic medium and is preheated to its ignition temperature before entering the combustion chamber. If the desired temperature cannot be achieved, additional auxiliary fuel, i.e. natural gas, is added in the combustion chamber (Sorrels et al., 2017). The first bed is cooled down while the gas is heated. The hot gas reacts in the combustion chamber and continues its course into the second bed, releasing energy and thus heating the ceramic packing of the second bed. The clean gas is then cooled down and released into the atmosphere. The process is carried out alternately so that in the next cycle, the inlet gas is preheated in the second bed and the first bed is where the hot gas is cooled. Using ceramic materials, the heat is stored and most of the energy produced by combustion is reused in the system itself without the need for additional heat exchangers (VDI guideline 3455:2013-08). This cyclic process achieves very high energy recovery. This reduces the auxiliary fuel requirements and saves operating cost. The destruction efficiency of the regenerative thermal oxidation is 95-99 % (STS BREF, 2020). Figure 9 shows the main air flows of a simple (2-bed) Regenerative Thermal Oxidizer (RTO). Introduction: Framework of this work 43 Figure 9. Representation of a simple Regenerative Thermal Oxidizer – Airflow diagram. (CMM, http://www.thecmmgroup.com). The typical RTOs use conventional (butterfly or poppet) valves to alternate the airflow direction through the ceramic beds. Since the late 1990s, some RTOs have been designed with rotary valves that reduce the number of moving parts requiring less maintenance (Sorrels et al., 2017). One problem that arose in RTOs is the release of untreated gas during the switch from one cycle to the next. This has been solved by adding more chambers to the abatement installation, leading to RTOs with three beds, five beds, etc. In these multi-chambered systems, the untreated gas is directed to the idle third chamber and then bled through the combustion chamber instead of going directly to the stack (Sorrels et al., 2017). Regarding the ceramic packing, several different types of materials are used for RTOs. These include random packing with ceramic saddles, monolithic (honeycomb) structured block and corrugated structure packing. Manufacturers constantly develop new materials and types of ceramic medium to improve their thermal efficiency, pressure drop, corrosion, and plugging or fouling. One important characteristic in new material compositions and shapes is the fact that they can be substituted without modifying the existing unit. 1.4.4.2.2 Recuperative Thermal Oxidation In recuperative thermal oxidation, the VOCs are oxidized in a simple oxidation chamber by chemical reaction with oxygen present in the exhaust air (STS BREF, 2020). The chamber has an auxiliary burner running on natural gas in which the waste gas is heated up to 700 °C-740 °C, leading to an almost complete oxidation, i.e. a destruction efficiency close to 100 % of the contained organic compounds (VDI guideline 3455:2013-08; STS BREF, 2020). Recuperative oxidizers have improved their energy efficiency by placing heat exchangers in the hot outlet gas streams. Thus, considerable fuel savings can be obtained by using the heat of the exit gas to preheat the inlet gas, the combustion air, or both via the heat exchangers, which can recover up to 70 % of the energy (enthalpy) in the hot exit gas (Sorrels et al., 2017). DANIEL GRANADERO REY 44 Besides, in vehicle paint shops the energy excess of the clean outlet gas can also be used to heat the drying ovens, which implies an additional benefit of this kind of technology. In these cases, a secondary heat exchanger is necessary. In Figure 10, the air flows of a common Recuperative Thermal Oxidizer are shown. Figure 10. Representation of a common Recuperative Thermal Oxidizer - Airflow diagram. (CMM, http://www.thecmmgroup.com). 1.4.4.2.3 Selection of abatement technology For the selection of one technology or the other, the advantages and drawbacks of both technologies must be carefully evaluated. Mainly, they can be summarized as follows: • As far as natural gas consumption is concerned, the installation of recuperative thermal oxidizers is usually considered more convenient since the excess heat can be reused to heat the drying ovens, with the consequent elimination of existing burners and the concomitant savings of natural gas. • The installation cost of an RTO is typically higher than that of a recuperative oxidizer. However, the treatment of high waste gas volumes might need the installation of several recuperative thermal oxidizers and their associated heat exchangers, while the same amount of waste gas can be treated by only one RTO, just by increasing the number of ceramic beds. This usually leads to higher initial investment costs for the recuperative thermal oxidizers. Maintenance costs are higher for the RTO, mainly due to the regular exchange of the ceramic packing. Generally, the installation of the RTO is more advantageous from an economic point of view. • For the installation of recuperative oxidizers, longer production shutdown periods are required due to the need to install and connect heat exchangers to recover the excess heat from the abatement systems and use it to operate the drying ovens. On the contrary, an RTO can be built independently and without disturbing the production process and only a few weeks of production shutdown are needed to finally connect the abatement system to the process. • The RTO is independent to the painting lines and ovens, so that in the event of breakdowns, production can continue without vehicle losses and production delays. Since the excess heat from the recuperative thermal oxidizers would be used to heat the Inventory of formaldehyde emissions 51 Table 6. Measurement program for paint shop 3. Measurement point designation Process related Abatement Temperature °C Operating conditions (utilized capacity %) Electrocoating oven exit before abatement 675 87 Electrocoating abatement treated waste gas 675 87 Electrocoating abatement treated waste gas 675 87 Primer Flash off N/A 76 Primer line 2 cooling zone N/A 93 Primer line 1 oven exit before abatement 540 83 Primer line 1 abatement treated waste gas 540 85 Primer line 1 oven exit before abatement 540 83 Primer line 1 abatement treated waste gas 540 85 Primer line 1 oven exit before abatement 540 83 Primer line 1 abatement treated waste gas 540 85 Topcoat line 2 flash off N/A 100 Topcoat 1 oven hold zone (no abatement) N/A 91 Topcoat 2 oven heat up zone (no abatement) N/A 98 Topcoat 2 oven hold zone (no abatement) N/A 98 Topcoat 2 cooling zone 1 (no abatement) N/A 98 Topcoat 2 cooling zone 2 (no abatement) N/A 98 Topcoat 3 oven hold zone (no abatement) N/A 80 Basecoat paint booth N/A 85 Basecoat paint booth N/A 85 Basecoat paint booth N/A 85 Basecoat paint booth abatement treated waste gas - 93 Basecoat paint booth abatement treated waste gas - 93 Basecoat paint booth abatement treated waste gas - 93 Basecoat clean air after Zeolite adsorption N/A 84 Basecoat spray booth VOC concentrated before abatement - 60 Basecoat spray booth abatement treated waste gas - 89 DANIEL GRANADERO REY 52 2.3.1.4 Paint shop 4 Section affected by copyright protection. The measurement program for this paint shop is similar to the program developed for the paint shop 1 since the type of paint shop and chimney profile is similar. As can be seen in Table 7, the concentrations of formaldehyde were also measured before and after the abatement systems in order to confirm the formaldehyde release in the ovens and the elimination or reduction in the abatement installation. Table 7. Measurement program for paint shop 4. 2.3.1.5 Paint shop 5 Section affected by copyright protection. The measurement program for this paint shop has a difference in comparison to the previous paint shops. Even though formaldehyde is not present in sealing and waxing materials, the chimneys from the sub-processes for the sealing and wax applications were also included in the measurement program to confirm the absence of formaldehyde in the waste gas. Although formaldehyde is not expected from those processes, it was known by the paint shop operators that the ducts and exhaust systems might be interconnected, and leaks of formaldehyde or other VOCs cannot be excluded. In Table 8 the measurement program for this paint shop is shown. Measurement point designation Process related Abatement Temperature °C Operating conditions (utilized capacity %) Cab painting - base coat painting, Cathodic immersion process Electrocoating, Paint mix, Evaporation between operations, Working platforms, Coagulation area. N/A 82 Cab chassis protection, Cab paint primer (Primer), Cab painting - Clear coat, local repair, tilting, removal of Electrocoating N/A 82 Electrocoating oven exit before abatement 710 82 Electrocoating abatement treated waste gas 710 82 Primer oven exit before abatement 710 82 Primer abatement treated waste gas 710 82 Primer oven exit before abatement 710 82 Primer abatement treated waste gas 710 82 Topcoat oven exit before abatement 710 82 Topcoat abatement treated waste gas 710 82 Topcoat oven exit before abatement 710 82 Topcoat abatement treated waste gas 710 82 Inventory of formaldehyde emissions 53 Table 8. Measurement program for paint shop 5. Measurement point designation Process related Abatement Temperature °C Operating conditions (utilized capacity %) PVC application 1 N/A 70 PVC application 2 N/A 70 Cavity wax application 1 N/A 70 Cavity wax application 2 N/A 70 Cavity wax application 3 N/A 70 Final Wax application 1 N/A 70 Final Wax application 2 N/A 70 Primer and Topcoat spray booth waste gas N/A 70 Electrocoating oven 1 exit before abatement 712 70 Electrocoating oven 2 exit before abatement 712 70 Electrocoating abatement 1 treated waste gas 712 70 Electrocoating abatement 2 treated waste gas 712 70 Primer oven exit before abatement 1 702 70 Primer abatement 1 treated waste gas 702 70 Primer oven exit before abatement 2 695 70 Primer abatement 2 treated waste gas 695 70 Topcoat oven exit before abatement 840 70 Topcoat abatement treated waste gas 840 70 2.3.1.6 Paint shop 6 Section affected by copyright protection. The measurement program for this paint shop was developed following the strategy of paint shop 1. For simplicity, only the direct emission points into the atmosphere were considered for the measurement program and any additional measurement before the abatement systems was excluded. This has been extensively analyzed for paint shops 2 to 5 and therefore it was not necessary to include such measurement in paint shop 6. The measurement points selected for paint shop 6 are shown in the Table 9. DANIEL GRANADERO REY 54 Table 9. Measurement program for paint shop 6. Measurement point designation Process related Abatement Temperature °C Operating conditions (utilized capacity %) Electrocoating abatement treated waste gas 810-815 95 Primer spray booth N/A 95 Primer abatement treated waste gas 815 95 Topcoat spray booth N/A 95 Topcoat flash off N/A 95 Topcoat abatement treated waste gas 720 95 Spray booth special vehicles painting N/A 95 Oven special vehicles painting exit after abatement 760 95 2.3.2 Methodology for formaldehyde measurements The measuring companies selected to perform the measurements must have the necessary accreditation to conduct the sampling and analysis for emissions measurements of formaldehyde. They must also have experience with the sampling since this is a complex procedure which, if not done correctly, can influence the results. For this reason, the selection of the measuring company was made under a thorough evaluation, and in some cases, companies were excluded from the selection as they did not comply with the established quality requirements. In specific cases, a subcontractor was engaged by the measuring company for the analysis of the samples in the laboratory. In this case, this company must also have the corresponding accreditation for the formaldehyde analysis. For the sampling of the waste gases, a difference between legal measurements and internal measurements must be made. Depending on the country legal requirements, the sampling might differ with regard to the sampling time. In general, taking three samples of 1 hour is the common procedure applied in legally required measurements. Since the formaldehyde measurements carried out in this work were internal measurements, a simplification of this procedure was applied in some of the paint shops in order to reduce the measurements time and the costs. In those cases, either the sampling time of the three samples was reduced to 30 minutes or only two samples of 1 hour were taken. The concentration of formaldehyde in the waste gas of the chimneys (emissions measurements) can be determined by different methodologies. The results obtained by the different methodologies are equivalent, being the main difference the sensitivity of the method. While one method is more suitable for measurements in ambient air, another method is more accurate when applied in waste gas from a chimney. The different measuring institutes applied the methodology they were accredited for. Nevertheless, the results were considered comparable regardless of the method by the paint shop and environmental engineers of the company as well as by the measuring company technicians. In specific cases, to validate the results, the first results obtained by applying one method were confirmed by applying a second method in the same paint shop under similar operating conditions. Inventory of formaldehyde emissions 55 The different methods applied for the determination of the formaldehyde concentrations are described in the following sections. 2.3.2.1 DNPH Method – Impinger Method The most common method for the determination of formaldehyde in waste gases applied by measuring companies in industrial processes is the DNPH method – Impinger method (VDI 3862 Part 2:2000-12). This method is typically used for the measurements of aliphatic and aromatic aldehydes and ketones in gas and wood firing installations, gas turbines, internal combustion engines and smoking facilities. In this method, the gaseous emissions are drawn into an impinger that contains an aqueous solution of 2,4-dinitrophenyl-hydrazine (DNPH). The samples taken on the field are subsequently brought to the laboratory for further analysis. Formaldehyde reacts with DNPH to form 2,4-dinitrophenylhydrazone. After extraction with an organic solvent, the samples are analyzed using HPLC to quantify the formaldehyde concentrations by analyzing the retention times and area counts of sample extracts with those of standard solutions. 2.3.2.2 XAD-2 Collection Tubes Method This methodology is equivalent to the DNPH method, but with the difference that instead of DNPH, formaldehyde reacts with 2-(hydroxymethyl) piperidine on a XAD-2 sorbent bed installed in sample collection tubes (EkoNorm communication, 2015). Regarding determination of formaldehyde in the samples, this method uses HPLC as in the DNPH method. 2.3.2.3 Multicomponent FTIR Gas Analyzer This method is typically used for continuous monitoring of formaldehyde, CO, NO, and NO2 in which the stationary equipment necessary for the measurements is permanently installed. In certain circumstances, this equipment can be installed only during the measurements campaign. This method is commonly used by manufacturers of paint shop equipment in order to analyze the efficiency of their installations, e.g., abatement systems. This method is not commonly used by measuring companies (ECA communication, 2015). In this method, when infrared radiation passes through a measuring cell containing an infrared active gas, the energy attenuates to a greater or lesser extent at certain wavelengths as the infrared radiation is absorbed by the molecules. Considering the strength of the absorption as well as the wavelength range in which absorption takes place, a large number of organic and inorganic gases and their concentration in the gas mixture can be determined. With the aid of an interferometer, the contribution of the individual wavelengths of the broadband infrared radiation can be measured. The calculation of the spectra from the interferometer data takes place by the fast Fourier transformation. When analyzing the measurement spectrum, the spectra of the individual gases are analyzed, and the concentrations of the different gases present in the sample can be calculated (Dürr report, 2016). 2.4 RESULTS AND DISCUSSION Section affected by copyright protection. Once all measurement programs were defined and the contracts with the measuring companies were established, the formaldehyde measurements were performed in each individual paint shop. The results obtained for each plant as well as their interpretation and discussion are given in this section. DANIEL GRANADERO REY 56 Based on the results, the emissions of formaldehyde from the painting process can be understood and the hypothesis stated in chapter 1 related to the sources for formaldehyde emissions into the atmosphere can be validated and confirmed. In specific cases, measurements were repeated under different operating conditions in order to evaluate the formaldehyde emissions in more detail or achieve a more in-depth knowledge on how the emissions vary depending on the settings of the paint shop processes. 2.4.1 Paint shop 1 Table 10 shows the results obtained for the paint shop 1. The measurements in this paint shop only include the direct emissions from chimneys into the atmosphere. Table 10. Measurement results for paint shop 1. Process related Abatement Temperature °C Average Formaldehyde concentration mg/m3 Measurement uncertainty (95%) mg/m3 Electrocoating abatement treated waste gas 720 0.8 0.2 Electrocoating abatement treated waste gas 710 <0.1 0.2 Primer and Topcoat Paint booths - 0.2 0.2 Top coat line 2 abatement treated waste gas 695 0.1 0.2 Top coat line 2 abatement treated waste gas 695 0.1 0.2 Top coat line 3 abatement treated waste gas 695 0.3 0.2 Top coat line 3 abatement cleaned gas 695 <0.1 0.2 Primer line 1 abatement treated waste gas 720 0.5 0.2 Primer line 2 abatement treated waste gas 720 1.0 0.2 Primer line 3 abatement treated waste gas 720 0.7 0.2 Evaluating these results, two important aspects can be seen. Firstly, the formaldehyde concentration observed in the emissions from the primer and topcoat paint booths is 0.2 mg/m3. This value is far below the European applicable emission limit value of 2 mg/m3 (Directive 2010/75/EU), confirming that the emissions of free formaldehyde from the usage of paints in the spray booths are low. The second observation is the fact that the emissions from the treated waste gas of the ovens after the abatement equipment are higher than those from the paint booths. For instance, in the primer lines, the concentration values are in the range of 0.5-1.0 mg/m3. This result suggests that inside the ovens the concentration of formaldehyde increases to a certain extent, providing a first evidence that formaldehyde is released in the ovens due to the presence of melamine resins in the paints. However, as a consequence of the oxidation in the abatement system, the amount of formaldehyde is reduced to values which are still below the applicable emission limit. Furthermore, considering that the abatement technology applied in this paint shop is recuperative thermal oxidation, it can also be concluded that the operation of this technology with temperatures close to 700 ºC and higher is sufficient to achieve a formaldehyde reduction below the legal emission limits. Inventory of formaldehyde emissions 57 2.4.2 Paint shop 2 The results obtained for paint shop 2 can be seen in Table 11. In this paint shop, additional intermediate points were selected for the measurements even if they are not direct discharges into the atmosphere. Specifically, samples of the waste gas from the ovens before it enters the abatement system for treatment were taken and the formaldehyde concentrations were determined. Table 11. Measurement results for paint shop 2. Process related Abatement Temperature °C Average Formaldehyde concentration mg/m3 Measurement uncertainty (95%) mg/m3 Electrocoating oven exit before abatement 702 10.4 0.4 Electrocoating abatement treated waste gas 702 0.6 0.1 Primer oven 1 exit before abatement 712 9.4 0.4 Primer oven 1 abatement treated waste gas 712 0.2 0.01 Primer oven 2 exit before abatement 712 11.7 0.5 Primer oven 2 abatement treated waste gas 712 < 0.1 < 0.1 Primer cooling zone N/A < 0.1 < 0.1 Topcoat oven 1 exit before abatement 706 62.7 0.3 Topcoat oven 1 abatement treated waste gas 706 0.5 0.1 Topcoat oven 2 exit before abatement 706 88.3 3.6 Topcoat oven 2 abatement treated waste gas 706 0.2 0.01 Topcoat oven 3 exit before abatement 706 11.9 0.5 Topcoat oven 3 abatement treated waste gas 706 < 0.1 < 0.1 Topcoat cooling zone N/A 0.5 0.02 Spray booths N/A 0.1 0.01 The results obtained in this paint shop confirm what was observed in paint shop 1 regarding the emissions of free formaldehyde from the spray booths. In this case, a formaldehyde concentration of 0.1 mg/m3 can be seen for the spray booths, which is comparable to that of paint shop 1 (0.2 mg/m3) and significantly below the applicable emission limit. On the other hand, high concentrations can be seen at the exit of the ovens prior to the treatment in the abatement system. This behavior is observed in all sub-processes. As an example, the results of the primer ovens are 9.4 mg/m3 and 11.7 mg/m3, respectively, before the abatement system and 0.2 mg/m3 and <0.1 mg/m3 after the treatment. An even more significant difference can be identified at the topcoat ovens, with concentration values before the abatement systems of 62.7 mg/m3, 88.3 mg/m3 and 11.9 mg/m3, respectively, and lower than 1 mg/m3 after the abatement system. These results confirm the release of formaldehyde in the drying ovens due to the use of melamine resins and the destruction of this substance in the abatement system working at temperatures greater than 700 ºC. In this case, similar to paint shop 1, recuperative thermal oxidizers are installed for the reduction of VOCs. An unexpected result was obtained for the electrocoating process. According to paint manufacturers, the materials used in this process do not contain melamine resins. Despite of DANIEL GRANADERO REY 58 that the concentrations of formaldehyde observed after the oven and before the abatement system are surprisingly high (10.4 mg/m3). This result led to an additional investigation of the electrocoating process and discussions with paint shop engineers. Even though the resins used in the electrocoating process are not melamine resins, it is suspected that formaldehyde residues might be present in the materials used in the electrocoating baths and can be released during the curing process, causing the high formaldehyde concentrations after the oven. In any case, the abatement system connected to the electrocoating ovens is able to reduce the formaldehyde emission below the legal emission limits. Additionally, a formaldehyde concentration of 0.5 mg/m3 was observed for the topcoat cooling zone. The cooling zone is the area in which the painted bodies are cooled down after the oven. The exhaust air from this area might be treated in the abatement system of the oven or directly discharged into the atmosphere, depending on the configuration of the paint shop. The concentration value obtained from the cooling zone confirms that this substance is released at temperatures greater than the ambient temperature and therefore the values are higher than those from the spray booths. Nevertheless, the emissions of formaldehyde from this area are below the legal emission limit even if this waste gas is directly discharged into the atmosphere. 2.4.3 Paint shop 3 The results of the measurements conducted in paint shop 3 are shown in Table 12. Like paint shop 2, several points before treatment in an abatement system were selected to confirm the release of formaldehyde in the drying ovens. As shown in chapter 1, the main difference of this paint shop compared to the others is the presence of abatement equipment for the waste gas of the basecoat spray booths and the fact that the topcoat ovens do not have an abatement system installed. Thus, if formaldehyde is released in the ovens, high concentrations of formaldehyde are expected in the oven waste gas. Inventory of formaldehyde emissions 59 Table 12. Measurement results for paint shop 3. Process related Abatement Temperature °C Average Formaldehyde concentration * mg/m3 Electrocoating oven exit before abatement 675 0.031 Electrocoating abatement treated waste gas 675 0.71 Electrocoating abatement treated waste gas 675 0.22 Primer Flash off N/A 3.4 Primer line 2 cooling zone N/A 1.16 Primer line 1 oven exit before abatement 540 12.26 Primer line 1 abatement treated waste gas 540 9.71 Primer line 1 oven exit before abatement 540 10.74 Primer line 1 abatement treated waste gas 540 10.01 Primer line 1 oven exit before abatement 540 4.37 Primer line 1 abatement treated waste gas 540 9.04 Topcoat line 2 flash off N/A 1.84 Topcoat 1 oven hold zone (no abatement) N/A 12.34 Topcoat 2 oven heat up zone (no abatement) N/A 13.95 Topcoat 2 oven hold zone (no abatement) N/A 10.11 Topcoat 2 cooling zone 1 (no abatement) N/A 0.08 Topcoat 2 cooling zone 2 (no abatement) N/A 0.09 Topcoat 3 oven hold zone (no abatement) N/A 14.23 Basecoat paint booth N/A 0.42 Basecoat paint booth N/A 0.04 Basecoat paint booth N/A 0.26 Basecoat paint booth abatement treated waste gas Not known 0.45 Basecoat paint booth abatement treated waste gas Not known 0.08 Basecoat paint booth abatement treated waste gas Not known 0.05 Basecoat clean air after Zeolite adsorption N/A 0.27 Basecoat spray booth VOC concentrated before abatement Not known 1.71 Basecoat spray booth abatement treated waste gas Not known 0.16 * 15 % Measurement Uncertainty The observations made for paint shops 1 and 2 can also be confirmed for paint shop 3. Besides, additional information was obtained from the measurement results of this paint shop. Firstly, the emissions from the spray booths are low, with concentration values below 0.5 mg/m3. This can be seen, for instance, in the basecoat spray booth measurement results (0.42, 0.04 and 0.26 mg/m3, respectively). In addition, the value observed in the exhaust air of the VOC concentration system (1.71 mg/m3) before the recuperative thermal oxidizer installed for the basecoat spray booth is higher than those from the basecoat spray booth. This behavior is plausible since the VOCs, including formaldehyde, are concentrated prior to their treatment in the abatement system. However, the emission values to the atmosphere after the treatment are low (0.45, 0.08 and 0.05 mg/m3, respectively), confirming that the abatement installation is reducing formaldehyde to levels below the applicable emission limit value. DANIEL GRANADERO REY 60 The flash off zones are intermediate tunnels where the solvents start to evaporate before the vehicle body enters the oven. They operate at temperatures in the range of 50ºC to 70ºC. The concentration results obtained in the waste gas from these areas, i.e., primer flash off (3.4 mg/m3) and topcoat line 2 flash off (1.84 mg/m3), suggest that at these temperatures, significant amounts of formaldehyde are already released. With regard to the ovens, the results confirm the observations previously made in paint shops 1 and 2. The emissions observed for the electrocoating oven are reasonable. Due to the use of recuperative thermal oxidizers with an operating temperature of 675 ºC to treat the waste gas from the oven, the concentrations of formaldehyde can be reduced to values lower than the applicable emission limit (0.71 and 0.22 mg/m3, respectively). However, when it comes to the primer and topcoat ovens, the results indicate that, when the operating temperature of the abatement systems is low or no abatement equipment is installed, the emissions of formaldehyde cannot be reduced, and the applicable emission limit value cannot be met. This behavior is confirmed by the results obtained for the primer oven. The recuperative thermal oxidizers connected to this oven operate at 540 ºC. The formaldehyde concentrations obtained for the exhaust gas after the treatment are in the range from 4.37 to 12.26 mg/m3, and thus higher than the applicable emission limit value. These results demonstrate that this temperature is not sufficient to reduce the formaldehyde concentration adequately. A more critical situation can be seen for the topcoat ovens, which do not have an installed abatement equipment. The formaldehyde concentrations are between 10.11 mg/m3 and 14.23 mg/m3. These values confirm again that formaldehyde is released in the drying ovens and without an abatement system, the emissions are higher than the applicable emission limit value. The results observed for the emissions after the abatement systems of the primer ovens led to an additional investigation. The operating temperature of 540 ºC is not sufficient to reduce formaldehyde to low values. Therefore, the temperature of these abatement installations was modified during normal production conditions and measurements at different temperatures were carried out. This investigation allows to obtain the correct temperature at which the formaldehyde concentrations are below the applicable emission limit value. Table 13 shows the measurements results for the exhaust gas of three primer oven abatement installations operating at different temperatures. Table 13. Measurement results of primer oven abatement systems at different temperatures. Abatement Temperature °C Abatement system 1 - Line 1 Average Formaldehyde concentration * mg/m3 Abatement system 2 - Line 1 Average Formaldehyde concentration * mg/m3 Abatement system 3 - Line 1 Average Formaldehyde concentration * mg/m3 360 10.6 500 3.3 7.7 9.0 550 11.7 600 0.31 0.47 10.4 650 1.8 0.05 6.4 700 1.7 1.7 2.9 730 0.13 0.40 0.14 * 15 % Measurement Uncertainty These results present some inconsistencies, specifically for the abatement system 1 and 2. As an example, the emissions at 600 ºC are lower than the values observed at 700 ºC (0.31 and 0.47 mg/m3 against 1.7 and 1.7 mg/m3, respectively). It is important to bear in mind that the Inventory of formaldehyde emissions 67 installations indicated that they had damaged or old parts that needed to be repaired or exchanged. The proposed actions for this paint shop consist of a complete exchange of the recuperative oxidizers for electrocoating and primer ovens as they reached the end of their lifetime and a removal and replace of the contaminated ceramic saddles in the RTO chambers. With this, a reduction of formaldehyde can be achieved. • Even though melamine resins are not used in electrocoating, significant concentrations of formaldehyde were observed in paint shop 2 at the exit of the oven before the abatement system (10.4 mg/m3). This result was attributed to formaldehyde residues that might be present in the materials used in the electrocoating baths and can be released during the curing process. Nevertheless, the electrocoating ovens were connected to recuperative thermal oxidizers that reduce formaldehyde to lower levels. • Unexpectedly high concentrations of formaldehyde were observed at the waste gas from the PVC and wax application zones in paint shop 5 (2.15 and 2.66 mg/m3). The results were mainly attributed to two reasons. Firstly, the ducts and exhaust systems of these areas might be interconnected with other zones of the painting processes and leaks of formaldehyde are possible. Secondly, accumulations of paint rests and sludge in the exhaust areas would cause a slow release of VOCs and formaldehyde through the chimney in higher concentrations than expected. A cleaning of these areas and a repetition of the measurements was proposed to the plant as actions to reduce the emissions and verify the effectiveness of this activity. Considering all these results, it can be concluded that paint shop 3 is the most affected facility since the installation of a completely new abatement system for the topcoat ovens is necessary to reduce the formaldehyde emissions. This paint shop was selected for the LCA and eco-efficiency analysis as described in chapter 3 and 4. The measurement results obtained in this paint shop were used as input to elaborate the inventory for these assessments. This chapter partially reproduces content already published as “Granadero, D. a b, Garcia-Muñoz, A. b, Adam, R. b, Omil, F. a and Feijoo, G. a, 2023. Evaluation of abatement options to reduce formaldehyde emissions in vehicle assembly paint shops using the Life Cycle methodology. Cleaner Environmental Systems, 11, 100139. ISSN 2666-7894, https://doi.org/10.1016/j.cesys.2023.100139. a CRETUS, Department of Chemical Engineering, School of Engineering, Universidade de Santiago de Compostela, 15782, Santiago de Compostela, Spain b Environmental Compliance and Sustainability, Stellantis, 65423, Rüsselsheim am Main, Germany More information on the Publications section at the end of this Ph.D. thesis. 3 LIFE CYCLE ASSESSMENT In chapter 2, the results of the formaldehyde measurements at the six paint shops of study as well as the actions proposed to reduce formaldehyde emissions were presented. In one of the six paint shops, high concentrations of formaldehyde were observed at the primer flash off, the waste gas from the primer abatement systems and the topcoat ovens operated without abatement. Concerning the actions to reduce the emissions, several proposals were made for the different processes. Firstly, the primer flash off waste gas shall be treated in the primer oven abatement systems. Secondly, the temperature of the primer oven abatement systems must be increased to 730 ºC to achieve a proper abatement efficiency. Finally, an abatement system was proposed to be installed at the topcoat ovens to treat the formaldehyde released during the paint curing process. For this purpose, two different technologic options as described in chapter 1 shall be considered. A Life Cycle Assessment (LCA) of the painting processes in this paint shop was performed from a “cradle-to-grave” perspective to analyze the environmental impacts before and after the introduction of the different improvement actions. With regard to the two topcoat oven abatement technologies evaluated, the LCA proved to be a reliable methodology to establish a comparison from the environmental sustainability point of view. 3.1 OBJECTIVES The main objectives pursued in the Life Cycle Assessment are: • Detect the hot spots from the main painting processes that cause the highest environmental impacts. • Propose possible future actions to reduce the impacts based on the hot spots identified. • Analyze the environmental impacts of the different actions that were already implemented in the paint shop to reduce formaldehyde emissions in order to compare the environmental situation before and after these actions. DANIEL GRANADERO REY 70 • Evaluate the change of the environmental impact of the painting process when introducing two different abatement systems for the reduction of formaldehyde emissions at the topcoat ovens, allowing the comparison of both technologies and supporting the selection of the most suitable system during the planning process. • Introduce a potential future improvement action and evaluate the implications in terms of its environmental impacts. • Perform a comparative analysis of all different scenarios of study from the total environmental impact and the human toxicity points of view to verify if the target of the Industrial Emissions Directive to protect the environment is achieved through these actions. 3.2 SCOPE From the entire painting process electrocoating, primer and topcoat were evaluated as they are the most relevant sub-processes in terms of atmospheric emissions and, in particular, formaldehyde releases. The study considered only the operation of the equipment while the construction of the installations was left out of the LCA. The environmental impact of pretreatment, sealing, waxing and repairing operations was considered not relevant and thus is not included in the scope of this work (VDI guideline 3455:2013-08). 3.2.1 Working conditions of the paint shop of study The main working conditions of the paint shop studied are described below. A detailed scheme of the mass and energy balance of these three sub-processes can be seen in Appendix 1. Electrocoating The paint shop has two parallel baths with two ovens per bath, operating at a set temperature of 195 °C. Each oven has two recuperative thermal oxidizers to remove VOC emissions and unpleasant odors. These abatement systems are working at a temperature of 675 °C. The ovens and the abatement installations are fed with natural gas through burners. The heat excess of the recuperative oxidizers is used to heat the oven by means of heat exchangers. Primer For the primer application, the paint shop has a line with several spray booths in which a coating of waterborne primer is applied to the vehicle bodies using robots. This coating material is previously mixed with water to adjust the viscosity. The spray booth is followed by a flash off area before the ovens. The primer line has three ovens operating at 185 °C with three recuperative thermal oxidizers per oven running on natural gas. The total of nine abatement installations are operating at 540 °C. With the use of heat exchangers, the excess of heat from the abatement systems is provided to heat the ovens. In addition, there are several supporting burners heating the ovens apart from the heat recovered from the recuperative oxidizers. Topcoat The topcoat process is divided in the basecoat and clearcoat application, which are studied together. The two steps are separated by an intermediate flash off area. A second flash off zone is placed after the clearcoat application booths. Both basecoat and clearcoat paints are solvent borne and they are mixed with additional solvent before their application in order to reach the desired viscosity. Part of the VOCs contained in the waste gas from the basecoat spray booths are concentrated in an activated carbon unit (Berenjian et al., 2012) and further oxidized in one Life Cycle Assessment 71 recuperative thermal oxidizer operating at 730 ºC. A second recuperative thermal oxidizer to increase the abatement capacity for the spray booth waste gas is installed but currently not in use. The topcoat process has four coating lines and two ovens at the end of each line, which makes a total of eight ovens running at 150 °C. The waste gas from the ovens is emitted to the atmosphere without abatement. 3.2.2 Functional unit All the inputs and outputs of the painting process are related to the functional unit. The paint shop processes 360,000 vehicles per year, which corresponds to about 75 % of its total capacity. The functional unit selected was 1 hour of operation for each sub-process investigated. 3.2.3 System Boundaries The system boundaries of this study are shown in Figure 12. Additionally, the figure illustrates the inputs and outputs to the sub-processes within scope as well as their background and foreground systems, used as the basis to elaborate the Life Cycle Inventory (LCI). Figure 12. Scheme of the system boundaries and background and foreground processes for the paint shop under evaluation. As inputs to the painting operations natural gas, electricity, purge solvents, water and electrocoating and painting materials were considered. The background processes are those related to the production and supply of materials and energy necessary to operate the installations: DANIEL GRANADERO REY 72 • Extraction and production of Natural Gas: Natural gas is needed to run the burners in order to heat the ovens and to operate the abatement equipment. It is provided by the natural gas supplier of the manufacturing plant. Its extraction and production processes cause environmental impacts, such as emissions to air, water depletion and wastewater generation (Shamoon et al., 2022). • Production of electricity: Electricity is necessary to operate the paint shop installations, such as robots, air supply for spray booths, compressed air and lighting. The contribution of each energy source for the electricity generation was taken from the country mix where the paint shop is located. • Production of Electrocoating, Primer and Topcoat materials and paints: The production of the various materials and paints used in the painting processes conforms a significant background process to this system. It implies raw material extraction, the use of energy and water for the production process, direct emissions, wastewater and waste generation (da Silva et al., 2016; Nair K et al., 2021; Shi et al., 2023). • Production of Solvents: Similar to the production of materials and paints, the manufacturing of solvents used for viscosity adjustment of the paints as well as for cleaning of painting equipment has associated environmental impacts. • Purification and supply of industrial and DI (deionized) water: Industrial and deionized water is used to carry out the electrocoating process and to wash out the overspray from the spray booths. Water coming from the river is processed and purified to be used in the paint shop in a series of decantation, decarbonization and filtration processes and, in the case of deionized water, a deionization process. The deionization is performed in an ionexchange resin system. As outputs from the painting operations the study reflects air emissions, waste and wastewater, whereof wastewater is treated onsite in a WWTP before discharge. In more detail, the foreground processes are: • Emissions into the atmosphere of VOC, dust and formaldehyde from paint booths, ovens and air emissions abatement equipment and CO, CO2 and NOx from burners and abatement equipment. • Release of wastewater pollutants in concentrations below given thresholds, i.e. COD, TOC, Zinc, Iron, Phosphorus, Oil & greases, suspended solids and Fluorides, after the treatment in an onsite WWTP discharged into the river. Wastewater treatment is included in the system boundaries of this work. • The generation of hazardous solid waste and other paint waste which leave the site to be treated in an off-site waste treatment facility. Waste treatment is outside of the system boundaries of this study. 3.3 DESCRIPTION OF SCENARIOS As described in chapter 2, several actions were proposed to reduce formaldehyde emissions. Some actions were immediately implemented by the company while others were further assessed due to their complexity in implementation and the associated costs. Each action introduces a modification in the operational conditions of the painting processes, which ultimately leads to a change in the environmental impacts of the paint shop. In order to compare the environmental impact associated with each action, different scenarios were defined and Life Cycle Assessment 73 analyzed. In this section, the various scenarios and the chronology of implementation of each of them are explained. 3.3.1 Chronology Figure 13 shows the implementation timeline of the different scenarios studied in this work for the paint shop of study. Figure 13. Implementation timeline of the different improvement scenarios. Each scenario corresponds to one or several actions to reduce formaldehyde emissions. The initial scenario was defined as “Base Case” and represents the paint shop as it was operating in 2015 before any action was taken to reduce formaldehyde emissions. In 2016, the first set of actions was implemented, and this was included in “Scenario A”. This consists of a reduction of the amount of free formaldehyde in the paints carried out by paint manufacturers and a decrease of the emissions from the primer process by introducing technical and operational improvements. In 2018, the company efforts were focused on reducing the emissions from the topcoat ovens. For this purpose, two alternative technologies were considered. “Scenario B” represents the installation of an RTO whereas “Scenario C” includes the installation of several recuperative thermal oxidizers. In addition, a potential future improvement scenario for the basecoat spray booth waste gas was analyzed as “Scenario D”. The different scenarios are described in more detail below. It is important to highlight that only the environmental impacts caused by the painting process working under these modifications were analyzed and not the impact of the implementation itself. 3.3.2 Scenario A The first scenario includes different actions immediately implemented in the paint shop when high levels of formaldehyde were identified through the measurements at the relevant chimneys. As explained in chapter 1, paint manufacturers improved their production processes to reduce the amounts of free formaldehyde in their paints due to the new hazardous classification of formaldehyde. In Scenario A, a reduction of the free formaldehyde concentration in the composition of the primer and topcoat paints from 0.3 % (weight) in the DANIEL GRANADERO REY 74 Base Case to 0.099 % was considered. The latter value corresponds to the maximum concentration possible (worst case) that the paints may have to avoid the disclosure of formaldehyde in the MSDS. As discussed in chapter 2, high concentrations of formaldehyde were detected in the primer flash off waste gas. The second action considered in Scenario A was the redirection of this waste gas stream to the primer ovens and thus ensure its treatment in the primer oven abatement systems. Furthermore, the abatement installations for the primer ovens were initially operating at 540 °C. The temperature of the primer oven abatement installations was raised to 730 °C. The increase of the natural gas consumption as well as the changes in the emissions of CO, VOCs, formaldehyde and NOx due to the modification of the temperature were included in Scenario A. 3.3.3 Scenarios B and C High concentrations of formaldehyde were also detected in the waste gas from the ovens placed at the end of the topcoat process. To reduce the emissions, two alternative treatment methods corresponding to the two different abatement technologies described in chapter 1 were considered. Each technology corresponds to one scenario. As part of this work, the number of installations for each type of technology necessary to treat the total waste gas volumes from the ovens was estimated. In addition, an evaluation of the energy demanded for each type of installation was performed. Scenario B Scenario B considers the installation of a 5-bed RTO for the topcoat ovens. The energy necessary for this installation is supplied by three burners with a nominal power of 0.9 MW each using natural gas as fuel. An abatement efficiency of 100 % was assumed for this system. Scenario C For Scenario C, eight recuperative thermal oxidizers are assumed to treat the waste gas volume from the topcoat ovens. To provide energy to the oxidizers, it is necessary to install one burner per oxidizer with a nominal power of 1.25 MWh using natural gas. The excess heat of the clean gases is used to heat the ovens, leading to an overall energy saving in the plant since the existing burners to heat the ovens would be shut down and removed. An abatement efficiency of 99 % was assumed for recuperative oxidizers. 3.3.4 Future improvement Scenario D In addition to the installation of an air emissions abatement system for the topcoat ovens, other future improvements were analyzed to reduce VOC and formaldehyde emissions. Currently, the plant has two recuperative thermal oxidizers installed for the treatment of the basecoat spray booths waste gas. To save energy, one of the two installations was switched off and thus only 50 % of the basecoat spray booth emissions are being treated. In Scenario D, the painting process with a complete treatment of the emissions from the basecoat spray booths was analyzed, that is, both oxidizers operating at its whole capacity. This scenario was simulated taking as a basis the data of Scenario B. Life Cycle Assessment 75 3.4 METHODOLOGY An attributional LCA of the painting process in the paint shop studied was performed from a “cradle-to-grave” perspective following the requirements and guidelines of the ISO 14040:2006 and ISO 14044:2006. 3.4.1 Impact assessment A Life Cycle Impact Assessment (LCIA) was conducted using commercial software SimaPro v.8.2 with European ReCiPe Midpoint V1.12 methodology, using the EcoInvent v3.2 database. This method is scientifically sound, easy to use and interpret, and internationally accepted. The method focuses on environmental impact and damage, distinguishing 18 different impact categories (Geldermann and Rentz, 2005; ILCD, 2010 a; ILCD, 2010 b; Goedkoop et al., 2013). The impact assessment is a technical, quantitative and qualitative process to characterize and measure the effects of the environmental burdens identified in the Life Cycle Inventory (LCI). This approach allows the identification of the elementary flows of the LCI that have a relevant effect to different environmental and human health impact categories. The following impact categories are considered within the selected methodology: • Climatic change (CC) (kg CO2 eq.): Impact related to the average increase of temperature of the terrestrial atmosphere and of the oceans observed in the last decades. The midpoint level uses the latest (2007) IPCC equivalency factors for three-time horizons (20, 100 and 500 years). • Ozone layer depletion (OD) (kg CFC-11 eq.): It measures the negative effects on the ability to protect against ultraviolet radiation from the atmospheric ozone layer. Based on time-explicit forecast of demographic developments up to 2100. • Terrestrial acidification (TA) (kg SO2 eq.): Linked to Ecosystem damage and time horizon dependent. It analyzes the decrease on the neutralizing capacity of soil. • Fresh water eutrophication (FE) (kg P eq.) and Marine eutrophication (ME) (kg N eq.): Excessive growth of the algae population due to the artificial enrichment of river, reservoir or marine waters as a result of the massive use of fertilizers and detergents. • Human toxicity (HT) (kg 1.4-DB eq.): It considers the harmful effects on human health due to the absorption of toxic substances through inhalation of air, food or water intake, or penetration through the skin. • Photochemical oxidant formation (POF) (kg NMVOC): Photochemical pollution occurs due to the presence of oxidants, caused by the reaction of nitrogen oxides, hydrocarbons and oxygen with ultraviolet radiation from the sun. It is the principal responsible of tropospheric ozone which is hazardous for the human health. • Particular matter formation (PMF) (kg PM10 eq.). Particles and inorganic substances with respiratory effects. It measures the harmful effects on human health due to particulate emissions and their precursors (NOx, SOx, and NH3). • Terrestrial ecotoxicity (TET), Fresh water ecotoxicity (FET) and Marine ecotoxicity (MET) (kg 1.4-DB eq.): Ecotoxicity is the result of a number of different toxicological mechanisms caused by the release of substances with a direct effect on the health of the ecosystem. These categories of environmental impact are related to the toxic impacts DANIEL GRANADERO REY 76 that affect to terrestrial, fresh water or marine ecosystems, that are harmful to different species and that change the structure and function of the ecosystem. • Ionizing radiation (IR) (kBq U235 eq.): Related to the damage to Human Health due to the radioactive material emissions to the environment. • Agricultural Land Occupation (ALO) and Urban Land Occupation (ULO) (m²a): Category of impact related to the use (occupation) and conversion (transformation) of an area of land by agricultural or urban activities. • Natural Land Transformation (NLT) (m2): Related to the change from one land use category to another. For example, plantation of forest on land previously used for agriculture. • Water depletion (WD) (m³), Metal depletion (MD) (kg Fe eq.) and Fossil depletion (FD) (kg oil eq.): Related to the consumption of material extracted directly from the environment. After the selection of the impact categories and the classification of the inventory results as the initial steps of the impact assessment, the characterization and normalization steps defined in the ISO 14040 and ISO 14044 standards were followed. 3.4.1.1 Characterization The ISO 14040 standard on Life Cycle Assessment determines the characterization as mandatory. The impact of each emission or resource consumption is modelled quantitatively with the use of characterization factors. The characterization of the painting process in its initial situation (Base Case) was performed to identify the sub-process with the greatest environmental impact. In addition, a characterization of each individual sub-process (electrocoating, primer and topcoat) was conducted to obtain the inputs and outputs with the highest contribution to the environmental impact. The next step was the characterization of the system for the Scenarios A, B and C, and finally Scenario D. 3.4.1.2 Normalization Although the ISO 14040 standard does not indicate the normalization as mandatory, it is useful to better compare the environmental impact of the painting process in the different analyzed scenarios. In this step, the results of the characterization step are normalized by expressing them with respect to a chosen reference system. For the comparison of the normalized data, in a first analysis, all 18 impact categories included in the methodology were taken into account. In subsequent stages, the most relevant impact categories were selected on the basis of these two criteria: • All impact categories whose relevant contribution to the total environmental impact was higher than 2 %. Eight categories could be identified by evaluating the normalization results. These eight relevant impact categories contribute to 95.5 % to the total environmental impact. • Human toxicity (HT) exclusively, since the reduction of human toxicity through the reduction of formaldehyde emissions due to its cancer-causing characteristic is the objective of the actions included in the different scenarios in this study. Life Cycle Assessment 83 Energy Natural Gas 15.2 MWh Paint shop energy records 1 Electricity 7.22 Paint shop energy records 1 Cogeneration 4.88 MWh Paint shop energy records 1, 6, 7 OUTPUTS: emissions to the environment Emissions to air Dust 10.71 kg Measured, Calculated 1, 4 NOx 35.02 kg Measured, Calculated 1, 4 CO 4.3 kg Measured, Calculated 1, 4 CO2 n.a. kg VOCs 200.57 kg Calculated 2 Formaldehyde 1.36 kg Measured, Calculated 1, 4 1 Data from the plant: reports, measurements. 2 VOC and material balances from the plant. 3 Safety Data Sheets from the materials (REACH). 4 Calculations based on data given by the plant. Assumptions were made in order to obtain the allocation of some data. 5 Internal communications from the plant or suppliers. 6 Data from a different plant of the same company with similar processes and equipment. 7 Bibliographic information from legislation, publications or books, allocation following BREF documents or provided from country specifications. 8 Other calculations Paint materials In 2015, 31 different paints for basecoat and one paint lacquer for clearcoat were used from three distinct suppliers. All MSDS of the paints were analyzed. Since these paints have similar composition except the paint used for white coating, two kinds of paints were included as subsystems with some variations in its composition. The subsystem called “Basecoat White” is associated to this specific white color paint, whose composition was provided by the paint supplier. The other subsystem, “Basecoat paint” includes the rest of the paints. Solvent All paints used in topcoat application were solvent-based. To achieve the necessary viscosity of the paints, they are mixed with two different solvents. The solvent included in the system combines the composition of both solvents specified in the MSDS for each one. Natural gas consumption, electricity and air emissions These values were obtained following the same procedure as in the previous process. CO2 emissions were not measured at the topcoat process so it was catalogued as not available data. Water emissions Allocation of wastewater for this process was not possible to establish. Missing data The percentage of additives included in the paints were known. However, additives are referred to a mixture of several compounds that was not possible to determine to be introduced in the system. As this amount is below 5 % of the total composition, it was left out of the system in the paints. DANIEL GRANADERO REY 84 3.5.3.4 Painting process To analyze the three sub-processes together in the SimaPro software and to have a global view of the whole painting process within the system boundaries, the three subsystems were included in a global system called “Painting process”. Moreover, all data that was not possible to separate and allocate in each process were added in this global system. Table 21 contains the data for the painting process that could not be allocated to the three subsystems. Table 21. LCI for the painting process. S1: Painting Process Unit Method / Source of data INPUTS: from Technosphere Materials Water DI 8.39 m³ Paint shop consumption records 1, 5 Purge solvent 73.1 kg Paint shop consumption records 1, 8 Industrial water 16.07 m³ Paint shop consumption records 1, 6, 8 OUTPUTS: emissions to the environment Emissions to air Dust 3.51 kg Measured, Calculated 1, 4 NOx 24.62 kg Measured, Calculated 1, 4 CO 7.4 kg Measured, Calculated 1, 4 CO2 433 kg Measured, Calculated 1, 4 VOCs 73.13 kg Calculated 2 Formaldehyde 0.12 kg Measured, Calculated 1, 4 Emissions to water COD 3.25 g O2 Measured, Calculated 1, 4 TOC 0.99 g Measured, Calculated 1, 4 Zinc 0.03 g Measured, Calculated 1, 4 Iron 0.03 g Measured, Calculated 1, 4 Phosphorus 0.11 g Measured, Calculated 1, 4 Oil & greases 0.11 g Measured, Calculated 1, 4 Suspended solids 0.59 g Measured, Calculated 1, 4 Fluorides n.a. g Waste Emulsion paints to incineration 4.37 kg Paint shop waste records 1 Paint to be separated 68.6 kg Paint shop waste records 1 Solid hazardous to incineration 1.78 kg Paint shop waste records 1 1 Data from the plant: reports, measurements. 2 VOC and material balances from the plant. 3 Safety Data Sheets from the materials (REACH). 4 Calculations based on data given by the plant. Assumptions were made in order to obtain the allocation of some data. 5 Internal communications from the plant or suppliers. 6 Data from a different plant of the same company with similar processes and equipment. 7 Bibliographic information from legislation, publications or books, allocation following BREF documents or provided from country specifications. 8 Other calculations Life Cycle Assessment 85 Water inputs The amount of water in the reports is referred to the total water consumption for the whole plant. To estimate the water for the processes within the system boundaries, information from other plants of the company was consulted. Purge solvent The purge solvent is used to clean the application guns and equipment in the primer and topcoat booths. The consumption data of this solvent was obtained from reports provided by the plant. This solvent includes virgin and recycled material. Emissions to air These values include the measurements results from the chimneys that discharge the waste gas from electrocoating, primer and basecoat booths together, and no allocation to the individual processes was possible. Emissions to water Wastewater measurements results from the primer and topcoat processes after the WWTP were included. Waste All main waste streams related to the painting processes were included. 3.5.4 Inventory for the improvement scenarios To analyze the impact of the different studied scenarios, several modifications in the inventories as explained above were required. Table 22 compiles the changes highlighting which process was affected. DANIEL GRANADERO REY 86 Table 22. LCI modifications for the studied scenarios. Process affected Base case Scenario A Scenario B Scenario C Scenario D Unit Source Material modification Primer paint (free formal.) Primer 0.30 % 0.099 % 0.099 % 0.099 % 0.099 % Paint suppliers3 Base Coat paint (free formal.) Topcoat 0.30 % 0.099 % 0.099 % 0.099 % 0.099 % Base Coat White paint (free formal.) Topcoat 0.30 % 0.099 % 0.099 % 0.099 % 0.099 % Clear coat paint (free formal.) Topcoat 0.30 % 0.099 % 0.099 % 0.099 % 0.099 % Energy modification Natural gas Primer 6.23 7.77 7.77 7.77 7.77 MWh Calculations* Natural gas Topcoat 15.2 15.2 17.9 12.7 19.0 MWh Calculations* Air emissions modification VOC Primer 1.84 1.32 1.32 1.32 1.32 kg/h VOC balance** VOC Topcoat 201 201 172 172 92.4 kg/h VOC balance** Formaldehyde Primer 0.545 0.009 0.009 0.009 0.009 kg/h Measurements 2015-20161 Formaldehyde Topcoat 1.36 1.36 0.475 0.475 0.285 kg/h VOC balance** NOx Primer 3.32 8.09 8.09 8.09 8.09 kg/h Measurements 2015-20161 NOx Topcoat 35.0 35.02 56.74 56.74 91.76 kg/h Measurements other abatement 2015 6 CO Primer 11.42 2.00 2.00 2.00 2.00 kg/h Measurements 2015-20161 CO Topcoat 4.27 4.27 9.63 9.63 13.90 kg/h Measurements other abatement 2015 6 * Calculations for the different scenarios are explained in Appendix 4. ** The specific VOC mass balance calculations considering the emission, transfer, abatement and waste factors for each scenario in each process are shown in Appendix 2. 1 Data from the plant: reports, measurements. 3 Safety Data Sheets from the materials (REACH). 6 Data from a different plant of the same company with similar processes and equipment. Paints Scenario A contemplates a change in the composition of all the paints used at the plant. The amount of free formaldehyde in the paints was reduced to a value below 0.1 %. Thus, the higher amount possible was assumed (0.099 %). This value was considered for the next scenarios. Natural Gas variation The variation of the natural gas for the Scenario A was provided by the paint shop engineers. In Appendix 4, the necessary data used to calculate the variation for the Scenarios B and C is shown. Finally, for Scenario D the variation assumed was two times the current consumption of the basecoat spray booth abatement system. VOC and formaldehyde VOC emissions were calculated by applying the VOC mass balance template simulating the different characteristics for each improvement scenario. The mass balances and the calculations can be seen in Appendix 2. Formaldehyde emissions for the different scenarios were estimated starting from the results of the measurements carried out in the paint shop as explained in chapter 2 and considering the improvements introduced by the different scenarios. Life Cycle Assessment 87 NOx and CO For the scenarios that were not implemented in the plant at the time this study was carried out, air emissions data related to the abatement installations (NOx and CO) were not available. Therefore, data from other plants of the company with similar processes and equipment were taken and adapted to the studied plant. 3.6 RESULTS AND DISCUSSION The Life Cycle Impact Assessment is the phase of the LCA that involves the evaluation of the magnitude and significance of the potential environmental impacts of the system. The interpretation is the evaluation of the results in relation to the objectives and scope of the work in order to reach conclusions and recommendations for improvement (ISO 14040:2006; ISO 14044:2006). Once all data were collected in the inventories described in the previous section and entered in the SimaPro software, the results were obtained and analyzed. This section presents the results of the characterization and normalization steps and provides an interpretation and discussion of the results in order to address the objectives described in chapter 3.1. 3.6.1 Characterization painting process Base Case In the characterization step, the hot spots were detected by analyzing the contribution of the different subsystems to the impact categories. An initial assessment of the overall painting process (Figure 15), comprising the inputs and outputs of the electrocoating, primer and topcoat processes, as well as all other inputs and outputs that could not be assigned to the three subsystems, shows that the topcoat process has the largest contribution for most impact categories. The smallest effect of the topcoat process can be noticed in the WD impact category with 42.7 m3 in a total of 248.8 m3 (17.1 %), whilst the highest share of this process in an impact category can be observed in POF with 252.2 kg NMVOC in a total of 419.2 kg NMVOC (59.5 %). Furthermore, the impact categories MD = 252.1 kg Fe eq. for the topcoat process (a contribution of 61.0 % to the total of the impact category), FET = 165.6 kg 1,4-DB eq. (57.8 %), MET = 138.1 kg 1,4 DB eq. (57.8 %), NLT = 1.53 m2 (57.3 %), OD = 0.001 kg CFC 11 eq. (55.8 %), ALO = 115.1 m2a (56.0 %), TET = 0.68 kg 1,4 DB eq. (54.3 %) and IR = 242.0 kBq U235 eq. (55.4 %) are remarkably affected by the topcoat process as the given percentages indicate. DANIEL GRANADERO REY 88 Figure 15. Results of the LCI characterization for the overall painting process in the Base Case (S1). Acronyms used in this figure: CC: Climate Change; OD: Ozone Depletion; TA: Terrestrial Acidification; FE: Freshwater Eutrophication; ME: Marine Eutrophication; HT: Human Toxicity; POF: Photochemical Oxidant Formation; PMF: Particulate Matter Formation; TET: Terrestrial Ecotoxicity; FET: Freshwater Ecotoxicity; MET: Marine Ecotoxicity; IR: Ionizing Radiation; ALO: Agricultural Land Occupation; ULO: Urban Land Occupation; NLT: Natural Land Transformation; WD: Water Depletion; MD: Metal Depletion; FD: Fossil Depletion. These results can be explained by the fact that the topcoat is the process with the highest consumption of materials and producer of emissions, in particular the use of solvent-borne paints, higher consumption of natural gas due to the use of more burners to heat the drying ovens than in the other sub-processes, and the direct emissions into the atmosphere without installed abatement systems. A similar outcome was observed by Bianco et al., 2020, specifically for the POF impact category, who identified the provision of heating and the direct emissions of VOCs as hot spots of the vehicle painting process. Additionally, it can also be observed that the electrocoating process plays an important role in all impact categories, with the greatest contribution in the categories of WD = 173.0 m3 (69.5 % contribution to the total of the impact category), PMF = 25.2 kg PM10 eq. (52.1 %), CC = 10224.5 kg CO2 eq (48.0 %), FD = 3587.1 kg oil eq. (45.9 %) and TA = 49.1 kg SO2 eq. (43.2 %), primarily due to the materials used in this process. Subsequently, the three subsystems were analyzed separately. 3.6.1.1 Characterization electrocoating process Base Case Figure 16 shows the results of the characterization of the electrocoating process. For most of the impact categories, the materials used in the electrocoating baths, i.e., the binder, consisting of organic solvents, epoxy resins and water, and the cationic paste, which is made of organic solvents, epoxy resins, pigments and water, make the greatest contribution. In particular, the cationic paste presents the largest impacts. For instance, in the NLT and the FE impact categories, the cationic paste represents 43.4 % (0.24 m2) and 59.1 % (0.31 kg P eq.) of the total Impact category, respectively. In order to identify which component of the cationic paste is responsible for this result, a characterization of the cationic paste based on its constituents was carried out. In this analysis, it was observed that the epoxy resin in the Life Cycle Assessment 89 formulation of the cationic paste is the main contributor to the majority of the impact categories, being POF = 0.02 kg NMVOC (97.3 % of the total of the impact category), FD = 1.07 kg oil eq. (97.2 %), PMF = 0.009 kg PM10 eq. (96 %), CC = 2.71 kg CO2 eq. (95.8 %) and TA = 0.016 kg SO2 eq. (93 %) the most affected categories. This result can be mainly explained due to the direct emissions of air pollutants associated with the resin production process, such as CO2 from combustion processes (Wilson, 2009). Figure 16. Results of the LCI characterization for the electrocoating process in the Base Case (SS1). Acronyms used in this figure: CC: Climate Change; OD: Ozone Depletion; TA: Terrestrial Acidification; FE: Freshwater Eutrophication; ME: Marine Eutrophication; HT: Human Toxicity; POF: Photochemical Oxidant Formation; PMF: Particulate Matter Formation; TET: Terrestrial Ecotoxicity; FET: Freshwater Ecotoxicity; MET: Marine Ecotoxicity; IR: Ionizing Radiation; ALO: Agricultural Land Occupation; ULO: Urban Land Occupation; NLT: Natural Land Transformation; WD: Water Depletion; MD: Metal Depletion; FD: Fossil Depletion. 3.6.1.2 Characterization primer process Base Case As can be seen in Figure 17, most of the impact categories are highly affected by natural gas consumption, given its background processes related to its extraction and production, each with a high impact. The direct emissions of the primer process are more relevant than in the electrocoating and have their main contribution to the impact categories of POF = 6.2 kg NMVOC (59.3 %), ME = 0.13 kg N eq. (41.7 %), PMF = 0.73 kg PM10 eq. (25.6 %) and TA = 1.86 kg SO2 eq. (21.2 %). With regard to the acidification and eutrophication impact categories, the high relevance of the direct emissions can be assigned to the NOx emissions coming from the oxidation process of the recuperative thermal oxidizers installed in the primer ovens, what confirms observations made by Banar and Çokaygi (2010). DANIEL GRANADERO REY 90 Figure 17. Results of the LCI characterization for the primer process in the Base Case (SS2). Acronyms used in this figure: CC: Climate Change; OD: Ozone Depletion; TA: Terrestrial Acidification; FE: Freshwater Eutrophication; ME: Marine Eutrophication; HT: Human Toxicity; POF: Photochemical Oxidant Formation; PMF: Particulate Matter Formation; TET: Terrestrial Ecotoxicity; FET: Freshwater Ecotoxicity; MET: Marine Ecotoxicity; IR: Ionizing Radiation; ALO: Agricultural Land Occupation; ULO: Urban Land Occupation; NLT: Natural Land Transformation; WD: Water Depletion; MD: Metal Depletion; FD: Fossil Depletion. 3.6.1.3 Characterization topcoat process Base Case The characterization results of the topcoat process are shown in Figure 18. To simplify the interpretation of the results, all created paint clusters were finally grouped into an individual system namely “Total paints”. Life Cycle Assessment 91 Figure 18. Results of the LCI characterization for the topcoat process in the Base Case (SS3). Acronyms used in this figure: CC: Climate Change; OD: Ozone Depletion; TA: Terrestrial Acidification; FE: Freshwater Eutrophication; ME: Marine Eutrophication; HT: Human Toxicity; POF: Photochemical Oxidant Formation; PMF: Particulate Matter Formation; TET: Terrestrial Ecotoxicity; FET: Freshwater Ecotoxicity; MET: Marine Ecotoxicity; IR: Ionizing Radiation; ALO: Agricultural Land Occupation; ULO: Urban Land Occupation; NLT: Natural Land Transformation; WD: Water Depletion; MD: Metal Depletion; FD: Fossil Depletion. These results present a similar behavior as for the primer process. Direct emissions considerably increase their relevance in the following impact categories: POF = 237.0 kg NMVOC (94.0 %), ME = 1.37 kg N eq. (69.2 %) and PMF = 7.7 kg PM10 eq. (52.6 %). Moreover, the share of the direct emissions in the TA impact category raises with 19.6 kg SO2 eq. to 47.2 %, 26 % higher than in the primer process. This trait can be attributed to two reasons. Firstly, the increment of the NOx emissions in the exhaust air of the recuperative thermal oxidizers installed in the basecoat spray booths. In particular, the high contribution of the direct emissions to the TA and ME categories is manifestly connected to the NOx emissions from the oxidation process (Banar and Çokaygi, 2010). Secondly, the increase of the VOC emissions from the topcoat ovens, where the solvent-borne paints are being cured without abatement equipment, unlike the primer process. The high impact of the direct emissions to the POF impact category is reasonable since VOCs are well-known precursors of photochemical smog and tropospheric ozone, as also discussed by Finlayson-Pitts (2000), Xu et al. (2015) and Xu et al. (2016). As shown in Figure 18, the relevance of the paints in most impact categories notably increased in comparison to the primer process. The highest contributions of the topcoat paints can be observed in WD = 27.8 m3 (65.3 %), ALO = 64.2 m2a (55.8 %) and IR = 105.0 kBq U235 eq. (43.4 %), whose relevance can presumably be traced back to the manufacturing process of the paints and to their constituents. As can be observed in the characterization results for all the sub-processes, natural gas consumption has a relevant influence on almost all impact categories and therefore on the total environmental impact of the painting process. For instance, in the topcoat process, CC = 3897.4 kg CO2 eq. (49.8 %), FD = 1338.2 kg oil eq. (42.9 %) and NLT = 0.55 m2 (36.2 %) are the most affected impact categories. Moreover, natural gas plays an important role in the OD DANIEL GRANADERO REY 92 impact category with a relevant contribution of 28.1 %. The contributions of the natural gas to the CC, FD and OD impact categories were already reported in other studies (Skone et al., 2016; Tomatis et al., 2019). 3.6.2 Characterization Scenario A Scenario A includes the reduction of free formaldehyde in the paints´ composition introduced by the paint manufacturers and the technical and operational modifications in the primer process. Comparing the characterization results of the overall painting process in Scenario A to those of the Base Case, it can be seen that the change in the paints did not significantly decrease the impacts of the topcoat process. This can be observed in all impact categories, which reduced their values by less than 0.1 %. The major improvements introduced in Scenario A were the reduction of the formaldehyde emissions in primer process by discharging the primer flash off waste gas into the primer oven and increasing the temperature of the primer oven abatement systems. Increasing the temperature of the abatement installations involves a relevant increase of the natural gas consumption. This higher consumption leads to a dramatical increase in almost all impact categories. The most affected categories are ME, with an increase of 62.2 % from 0.31 kg N eq (Base Case) to 0.51 kg N eq (Scenario A), PMF (Base Case = 2.85 kg PM10 eq; Scenario A = 4.14 kg PM10 eq; 45.7 %), TA (Base Case = 8.78 kg SO2 eq; Scenario A = 12.45 kg SO2 eq; 41.8 %) and CC (Base Case = 2735 kg CO2 eq; Scenario A = 3129 kg CO2 eq; 14.4 %). With regard to the ME and TA impact categories, the raise can be attributed to the higher NOx emissions as a result of the temperature increase (Banar and Çokaygi, 2010). The main objective in reducing the formaldehyde emissions is to achieve an improvement in the human toxicity (HT) impact category. Therefore, the comparison of the HT in the two scenarios was made and the results are illustrated in Figure 19. Figure 19. Results of the LCI characterization for the overall painting process in Base Case and Scenario A. Comparison HT values for the primer subsystem. The figure shows the characterization results of the overall painting process for the HT impact category with the focus on the primer subsystem. HT considerably decreases its impact from Life Cycle Assessment 99 identification of the most environmentally sustainable alternative providing relevant information for the selection during the planning process. Based on the results obtained in the LCA and the interpretations and discussion given in this chapter, the following conclusions can be drawn: • Analyzing the hot spots from the overall painting process it can be concluded that the topcoat process causes the highest environmental impacts. This result is attributed to the significant consumption of materials and production of emissions of this sub-process, the higher consumption of natural gas, and the direct emissions into the atmosphere without installed abatement systems. Improvements in the production of paints and their constituents itself, for instance by reducing the solvent content or replacing substances by less harmful alternatives, should be further strived by paint manufacturers to reduce the environmental impacts of vehicle paints shops. • Furthermore, the electrocoating was also identified as a process that causes a relevant environmental impact in the paint shop. In particular, the epoxy resin used in the cationic paste is the main responsible for the environmental impacts of this process. Therefore, a possible future action for paint manufacturers should be the research and development of alternative resins that can be used to produce electrocoating materials with a lower environmental impact, or a modification in their production process leading to a reduction of the CO2 emissions. • Scenario A introduces a reduction of the formaldehyde emissions, mainly in the primer process, by treating the flash off emissions and increasing the temperature of the oven abatement systems. Comparing the results of Scenario A to the original situation of the paint shop (Base Case), a decrease of 7 % of the HT impact category can be observed in the primer process. Consequently, Scenario A achieves the pursued reduction of the human toxicity. However, the higher natural gas consumption led to an increase in almost all other impact categories. • Scenarios B and C studied two different abatement technologies, i.e., regenerative thermal oxidation and recuperative thermal oxidation, currently used in vehicle paint shops across the world for the elimination of VOCs and, particularly, formaldehyde emissions. Comparing both scenarios with Scenario A, it can be concluded that: o While both abatement technologies achieved a decrease in the human toxicity due to the reduction of formaldehyde emissions, the implementation of recuperative thermal oxidizers (Scenario C) reached a more significant human toxicity reduction than the regenerative thermal oxidation technology (Scenario B) (5.3 % and 1.5 % reduction of the normalized index in the HT impact category for the overall painting process, respectively). o The recuperative thermal oxidizers (Scenario C) achieved an overall improvement when considering the most relevant impact categories selected in this study, unlike the regenerative thermal oxidizer (Scenario B) (1 % reduction of the normalized index observed for the recuperative thermal oxidizers against 2 % increase for the regenerative thermal oxidizer when considering the complete painting process). o These results can be mainly explained by the higher overall energy consumption of the regenerative thermal oxidation technology. Thus, the installation of the DANIEL GRANADERO REY 100 recuperative thermal oxidizers is the most environmentally sustainable alternative. • Scenario D reduces the VOC and formaldehyde emissions. However, it does not achieve a reduction of the HT impact category, with a result very close to that of Scenario B and significantly higher than Scenario C. This can be attributed to the increase of the natural gas consumption of Scenario D. • All improvement scenarios aimed at reducing the emissions of formaldehyde and thus the HT impact category. The results obtained in the LCA confirm that all studied scenarios achieve the pursued reduction if they are compared to the Base Case. However, the magnitude of this reduction is different for the different scenarios. The subsequent implementation of Scenario A followed by Scenario C represents the most environmentally sustainable option in view of both human toxicity and the total environmental impact. The target of the Industrial Emissions Directive to protect the environment is achieved through the implementation of the actions proposed in these two scenarios. All in all, these results provide valuable information to the company for the selection of the most suitable actions to reduce formaldehyde emissions. LCA has been confirmed as a powerful tool that can be applied during the planning and selection activities to evaluate and identify the most environmentally sustainable technology. Nevertheless, the economic aspect has not yet been included in the evaluation. The eco-efficiency analysis conducted in chapter 4 considers the costs for implementation of the Scenarios B or C an provides the company with additional input for the decision-making. This chapter partially reproduces content already published as “Granadero, D. a b, Garcia-Muñoz, A. b, Adam, R. b, Omil, F. a and Feijoo, G. a, 2023. Evaluation of abatement options to reduce formaldehyde emissions in vehicle assembly paint shops using the Life Cycle methodology. Cleaner Environmental Systems, 11, 100139. ISSN 2666-7894, https://doi.org/10.1016/j.cesys.2023.100139. a CRETUS, Department of Chemical Engineering, School of Engineering, Universidade de Santiago de Compostela, 15782, Santiago de Compostela, Spain b Environmental Compliance and Sustainability, Stellantis, 65423, Rüsselsheim am Main, Germany More information on the Publications section at the end of this Ph.D. thesis. 4 ECO-EFFICIENCY ANALYSIS OF ABATEMENT EQUIPMENT FOR FORMALDEHYDE EMISSIONS REDUCTION The study conducted in chapter 2 explained the necessity to implement specific actions in paint shop 3 to reduce the formaldehyde emissions below the applicable emission limit value. The Life Cycle Assessment described in chapter 3 demonstrated that the sequential implementation of the actions included in Scenario A (reduction of free formaldehyde in paints, removal of primer flash off emissions and increasing the primer oven abatement temperature) and Scenario C (installation of recuperative thermal oxidizers for the topcoat ovens) not only ensures meeting the legal requirements, but also reduces the overall environmental burdens of the paint shop. On the contrary, the combination of Scenario A and Scenario B (installation of an RTO for the topcoat ovens) implies an increase of the total environmental impact of the paint shop while ensuring legal compliance regarding formaldehyde emissions. For the selection of the most suitable abatement technology, i.e., RTO or recuperative thermal oxidation, not only the environmental sustainability aspect can be considered by the company. Beside the technical and environmental evaluation also an economic assessment of the potential solutions is of importance for decision making. Eco-efficiency assessment is a quantitative tool to study the environmental impacts of a system in conjunction with its economic value (ISO 14045:2012) and helps entities to make conscious decisions (Torregrossa et al., 2018; Ramírez-Melgarejo et al., 2021). Thus, eco-efficiency analysis establishes a connection between the ecological impact of a system and its economic dimension (Desli et al., 2021). In this chapter, an eco-efficiency analysis of the two abatement options for the topcoat ovens was performed to introduce the cost factor into the evaluation and support the company in the decision-making process. Furthermore, considering the results obtained in this and the DANIEL GRANADERO REY 102 previous chapters, a proposal for the best eco-efficient paint shop in view of formaldehyde emissions performance is given. 4.1 OBJECTIVES The main objectives of this chapter are: • Perform an economic evaluation of the two abatement options for the topcoat ovens as described in Scenario B and Scenario C of chapter 3. • Carry out an eco-efficiency analysis using the results of the LCA of chapter 3 and the economic evaluation. • Define the most environmentally sustainable and the most economically favorable abatement option. • Explain the final decision of the company. • Make a proposal for the best eco-efficient paint shop in view of formaldehyde emissions performance. 4.2 SCOPE The eco-efficiency analysis was performed to compare the two abatement options included in Scenario B and Scenario C described in chapter 3. Both scenarios were evaluated as alternatives to reduce the high formaldehyde emissions from the waste gas of the topcoat ovens of paint shop 3, as confirmed by the investigation conducted in chapter 2. Scenario B corresponds to the installation of a 5-bed RTO, while Scenario C implies the installation of eight recuperative thermal oxidizers. Figure 24 represents the different scenarios to simplify the interpretation of the results. Figure 24. Illustration of Scenarios B and C with Scenario A as starting point as studied in the eco-efficiency analysis. Eco-efficiency analysis of abatement equipment for formaldehyde emissions reduction 103 4.3 METHODOLOGY As a prerequisite for the eco-efficiency analysis, an initial study of the two abatement systems was performed, including an economic evaluation to obtain all necessary economic data. The capital costs for the installation of the two systems were requested from equipment manufacturers for the paint shop studied. The operational and maintenance costs data were available from other company plants with similar equipment. These costs were calculated for the whole lifespan of the installations and the annual increase in the cost of natural gas (OMIP, 2018) and spare parts for equipment was taken into account using the average inflation rates of recent years of the country where the paint shop is located (INE, 2017). A detailed calculation of the natural gas costs is given in Appendix 5. Finally, the total costs were normalized to the functional unit to allow the comparison between the two systems. The eco-efficiency analysis was conducted based on the criteria prescribed in the ISO 14045:2012. The analysis was performed with the focus set on the topcoat process, for which the abatement equipment was planned. The normalization results previously obtained in the LCA were used for the eco-efficiency evaluation. Two different indicators were selected and represented against the total cost per hour: • Variation of the normalized index, expressed in percentage, considering the sum of the impact categories with a relevant contribution to the total environmental impact greater than 2 % in the normalization results. • Variation of the normalized index, expressed in percentage, of the HT impact category. It must be highlighted that, even though the LCA did not consider the construction of the painting installations but only the operation of the equipment, the costs for the installation of the two planned abatement systems could not be excluded. They are the major cost factor in the total calculated costs of the two systems and are necessary to achieve a representative comparison. Besides, all other painting equipment and installations were already available in the paint shop at the time of this study and no additional investment would be necessary. 4.4 RESULTS AND DISCUSSION The results of the economic evaluation are summarized in Table 24. Table 24. Implementation costs for RTO and Recuperative Thermal Oxidizers. Scenario B: RTO Scenario C: Recup. Oxidizers Unit Lifetime 25 15 Years Installation cost 7.3 25 Million € Maintenance 84000 43200 € / Year Natural gas 56.3 -52.3 € / h Total cost / h 136.85 305.36 € / h The difference observed in the lifetime of the two abatement systems is inherent to the type of equipment. Recuperative oxidizers have more parts that deteriorate over time, and after several years an exchange or repair is no longer possible. Consequently, the complete equipment needs to be replaced. Regarding the installation cost, the much higher value shown for the recuperative oxidizers is due to the fact that, for this technology, eight pieces of equipment would be needed to treat the complete waste gas from the topcoat ovens. This implies the installation of the eight DANIEL GRANADERO REY 104 systems together with their corresponding heat exchangers and burners. Additionally, the existing burners to heat the ovens would be shut down and removed, which increases the cost. In the case of the RTO, only one larger system with 5 ceramic beds and three burners would be sufficient. It was calculated that one hour of operation of the RTO implies a cost of 136.85 € while for the eight recuperative thermal oxidizers, the costs reach 305.36 €. The results of the eco-efficiency analysis are represented in Figure 25 for the selected relevant impact categories and Figure 26 for the HT impact category. The percentage variation of the normalized index has been assessed with the calculated total costs in € per hour of operation for both types of technology. Considering all selected relevant impact categories (Figure 25), it can be recognized that the installation of the recuperative thermal oxidizers to reduce formaldehyde emissions is the most environmentally sustainable alternative (it leads to a 2.6 % reduction of the normalized index against a 3.1 % increase for the RTO), although the costs are 2.2 times those of the RTO. On the other hand, the most economically favorable abatement technology is the installation of the RTO. Figure 25. Results of the eco-efficiency analysis for the topcoat process: selected relevant impact categories. Regarding the reduction of the HT impact category, the two technologies can also be compared from the perspective of eco-efficiency in Figure 26. Eco-efficiency analysis of abatement equipment for formaldehyde emissions reduction 105 Figure 26. Results of the eco-efficiency analysis for the topcoat process: Human Toxicity (HT). This graph clearly illustrates the difference in the reduction of the human toxicity achieved by both technologies considering their implementation costs. Even though a reduction is obtained by both technologies, the costs to gain a reduction of more than 10 % of the HT impact category for the topcoat process are much higher for the implementation of the eight recuperative thermal oxidizers (305.36 €/h and 136.85 €/h, respectively). From these results, it can be concluded that the implementation of the recuperative thermal oxidizers is a better solution if a higher reduction of the human toxicity is pursued and the higher costs are not a relevant factor. 4.5 FINAL DECISION OF THE COMPANY Section affected by copyright protection. DANIEL GRANADERO REY 106 Eco-efficiency analysis of abatement equipment for formaldehyde emissions reduction 107 DANIEL GRANADERO REY 108 4.6 PROPOSAL FOR BEST ECO-EFFICIENT PAINT SHOP IN VIEW OF FORMALDEHYDE EMISSIONS PERFORMANCE The investigation conducted in this Ph.D. thesis allowed to identify the areas and processes of the vehicle paint shop from which high formaldehyde emissions into the atmosphere occur. Once these processes were identified, actions to reduce the emissions could be proposed and evaluated from a technical, environmental and economic perspective. This supported the company in the planning process to select the best options to reduce the formaldehyde emissions and comply with the applicable legislation while achieving a right balance between environmental protection and cost efficiency. The outcomes of this research can also be applied to propose a general layout or setting for the best eco-efficient paint shop in view of formaldehyde emissions performance. The main characteristics of this paint shop are summarized in Table 25. General conclusions 115 As an initial step, a Life Cycle Impact Assessment (LCIA) of the overall painting process in the original situation of the paint shop of study was carried out. Analyzing the hot spots, it could be concluded that the topcoat process causes the highest environmental impacts. This result was explained by the significant consumption of materials and production of emissions of this sub-process, the higher consumption of natural gas, and the direct emissions without installed abatement systems. Additionally, the electrocoating was also identified as a process with a relevant contribution to the total environmental impact, mainly due to the epoxy resin contained in the cationic paste used in this process. Improvements in the production of paints and materials, and their constituents itself, should be further pursued by paint manufacturers to reduce the environmental burdens of vehicle paints shops. Once the overall painting process was analyzed, various improvement scenarios were evaluated, each of them corresponding to the different actions proposed to reduce the formaldehyde emissions in the paint shop. Firstly, a scenario (Scenario A) that included the reduction of free formaldehyde in paints, the treatment of the primer flash off emissions, and the increase of the temperature of the primer oven abatement installations, was studied and compared to the original situation of the paint shop (Base Case). Comparing the results of Scenario A to the Base Case, a decrease of 7 % of the human toxicity (HT) impact category was observed in the primer process. Consequently, Scenario A achieves the pursued reduction of the human toxicity through the formaldehyde emissions reduction. However, the higher natural gas consumption of this scenario due to the increase of the abatement temperature led to an increase in almost all other impact categories. Following the analysis of Scenario A, two further scenarios for the reduction of formaldehyde emissions from the topcoat ovens were analyzed and compared to the paint shop in Scenario A. These scenarios (Scenarios B and C) studied two different abatement technologies, i.e., regenerative thermal oxidation (RTO) and recuperative thermal oxidation, respectively. It was observed that both abatement technologies achieved a decrease in the human toxicity due to the reduction of formaldehyde emissions. However, the implementation of recuperative thermal oxidizers (Scenario C) reached a more significant human toxicity reduction than the RTO (Scenario B) (5.3 % and 1.5 % reduction of the normalized index in the HT impact category for the overall painting process, respectively). On the other hand, the recuperative thermal oxidizers achieved an overall improvement when considering the most relevant impact categories selected in this study, unlike the RTO (1 % reduction of the normalized index observed for the recuperative thermal oxidizers against 2 % increase for the RTO when considering the complete painting process). These results were explained by the higher overall energy consumption of the regenerative thermal oxidation technology. Thus, the installation of the recuperative thermal oxidizers is the most environmentally sustainable alternative. An additional scenario to reduce the VOC and formaldehyde emissions was also analyzed (Scenario D). This included the complete treatment of the emissions from the basecoat spray booths. This scenario did not achieve a reduction of the HT impact category. The improvement in the HT caused by the reduction of VOC and formaldehyde emissions is compensated by a deterioration due to the increase of the natural gas consumption. The results obtained in the LCA confirmed that all studied scenarios achieve the pursued reduction of the human toxicity if they are compared to the original situation of the paint shop. However, the magnitude of this reduction is different for the different scenarios. The subsequent implementation of Scenario A followed by Scenario C represents the most environmentally DANIEL GRANADERO REY 116 sustainable option in view of both human toxicity and the total environmental impact. Nevertheless, the economic aspect has not been yet included in the evaluation of chapter 3. In order to provide the company with additional input for the decision-making and select the most suitable technology for the abatement of the topcoat oven emissions, an economic evaluation and an eco-efficiency analysis were conducted. The economic evaluation and eco-efficiency analysis described in chapter 4 were performed to compare the two abatement options for the topcoat ovens of paint shop 3. In the economic evaluation, all cost data necessary to carry out the eco-efficiency analysis were collected, including installation, operational and maintenance costs of the two abatement systems over their lifetime. The eco-efficiency analysis demonstrated that in cases where only the reduction of the formaldehyde emissions to ensure legal compliance along with an overall improvement of the human toxicity are pursued and the costs are the main factor in the decision-making process, the RTO is the most economically favorable abatement option. The total costs for the implementation of the recuperative thermal oxidizers were 2.2 times those of the RTO (305.36 €/h and 136.85 €/h, respectively). Thus, the decision of the company to install an RTO at the topcoat ovens of paint shop 3 could be justified by these results. Finally, in chapter 4 a proposal for the best eco-efficient paint shop in view of formaldehyde emissions performance was given. This proposal includes all the knowledge and outcomes acquired in this Ph.D. thesis and considers the installation of recuperative thermal oxidizers for the topcoat ovens as the best option to reduce the formaldehyde emissions decreasing the environmental footprint of the paint shop. The results provide new information to vehicle manufacturers and paint shop operators, facilitating the decision-making process in the selection of the most suitable abatement technology for the reduction of formaldehyde emissions. LCA and eco-efficiency analysis have been confirmed as powerful tools that can be applied during the planning and selection activities to evaluate and identify the most environmentally sustainable technology. REFERENCES ACEA Automobile Industry Pocket Guide 2022-2023, 2022. European Automobile Manufacturers’ Association (ACEA). https://www.acea.auto/publication/automobileindustry-pocket-guide-2022-2023/. ACEA Internal information for WG-IE members, Working Group Industrial Emissions, 2014. Akafuah, N. K., Poozesh, S., Salaimeh, A., Patrick, G., Lawler, K., Saito, K., 2016. Evolution of the Automotive Body Coating Process—A Review. Coatings 2016, 6(2), 24. https://doi.org/10.3390/COATINGS6020024. Banar, M., Çokaygil, Z., 2010. Life Cycle Assessment of electricity production from natural gas combined cycle. Chemical Engineering Transactions, 21, 157 – 162. https://doi.org/10.3303/cet1021027. Berenjian, A., Chan, N., Malmiri, H.J., 2012. Volatile Organic Compounds Removal Methods: A Review. Am. J. Biochem. Biotechnol, 8, 220–229. https://doi.org/10.3844/ajbbsp.2012.220.229. Bianco, I., Panepinto, D., Blengini, G. A., Onofrio, M., Zanetti, M., 2020. Inventory and life cycle assessment of an Italian automotive painting process. Clean Techn Environ Policy, 22, 247–258. https://doi.org/10.1007/s10098-019-01780-3. Bolt, H. M., Johanson, G., Nielsen, G. D., Papameletiou, D. and Klein, C. L., 2016. SCOEL/REC/125 Formaldehyde. Recommendation from the Scientific Committee on Occupational Exposure Limits. European commission. Borwankar, D. S., Anderson, W. A., Fowler, M., 2012. A Technology Assessment Tool for Evaluation of VOC Abatement Technologies from Solvent Based Industrial Coating Operations. Air Qual. - New Perspect. https://doi.org/10.5772/45745. Brummer V., Yong Teng, S., Jecha, D., Skryja, P., Vavrcikova, V., Stehlik, P., 2022. Contribution to cleaner production from the point of view of VOC emissions abatement: A review. Journal of Cleaner Production, 361, 132112. https://doi.org/10.1016/j.jclepro.2022.132112. DANIEL GRANADERO REY 118 Bysko, S., Krystek, J., Bysko, S., 2020. Automotive Paint Shop 4.0. Computers & Industrial Engineering, 139, 105546. https://doi.org/10.1016/j.cie.2018.11.056. CMM. Regenerative and Recuperative Thermal oxidiser information. Available at http://www.thecmmgroup.com/ (Last access 09/2023). da Silva, L. F., Barbosa, A. D., de Paula, H. M., Romualdo, L. L., Andrade, L. S., 2016. Treatment of paint manufacturing wastewater by coagulation/electrochemical methods: Proposals for disposal and/or reuse of treated water, Water Research, 101, 467-475. https://doi.org/10.1016/j.watres.2016.05.006. Debnath, N.C., 2013. Importance of Surface Preparation for Corrosion Protection of Automobiles. J. Surf. Eng. Mater. Adv. Technol, 94–105. https://doi.org/10.4236/jsemat.2013.31A014. Desli, E., Gkoulgkoutsika, A., Sdrolia, E., Zarotiadis, G., 2021. Eco-efficiency: Α methodological framework and assessment. Cleaner Environmental Systems, 3, 100049. https://doi.org/10.1016/j.cesys.2021.100049. Directive 2010/75/EU of the European Parliament and of the Council of 24 November 2010 on industrial emissions (integrated pollution prevention and control), 2010. Official Journal of the European Union. http://data.europa.eu/eli/dir/2010/75/oj. Dürr Emission measurement report, Dürr Systems AG, 2016. Internal measurement report from measuring company. ECA Communication, Entidad Colaboradora de la Administración, S. L. U., 2015. Internal communication from measuring company. EkoNorm Communication, EkoNorm Sp. z o. o., 2015. Internal communication from measuring company. Finlayson-Pitts, B. J., Pitts, J. N., 2000. CHAPTER 1 - Overview of the Chemistry of Polluted and Remote Atmospheres. Chemistry of the Upper and Lower Atmosphere, Academic Press, 1-14. https://doi.org/10.1016/B978-012257060-5/50003-4. Formacare, Outlook for formaldehyde in the European Union, 2014. www.formacare.org. Geldermann, J., Rentz, O., 2005. Multi-criteria Analysis for Technique Assessment Case Study from Industrial Coating. Journal of Industrial Ecology, 9 (3), 127-142. https://doi.org/10.1162/1088198054821591. German Environment Agency, 2023. Umweltbundesamt, Nationale Trendtabellen für die deutsche Berichterstattung atmosphärischer Emissionen seit 1990, Emissionsentwicklung 1990 bis 2021 (Stand 03/2023). https://www.umweltbundesamt.de/daten/luft/luftschadstoff-emissionen-in- deutschland/emission-fluechtiger-organischer-verbindungen-ohne#entwicklung-seit- 1990. References 119 Giampieri, A., Ling-Chin, J., Ma, Z., Smallbone, A., Roskilly, A.P., 2020. A review of the current automotive manufacturing practice from an energy perspective. Appl. Energy, 261, 114074. https://doi.org/10.1016/J.APENERGY.2019.114074. Giampieri, A., Ma, Z., Ling-Chin, J., Smallbone, A. J., Roskilly, A. P., 2022. A technoeconomic evaluation of low-grade excess heat recovery and liquid desiccant-based temperature and humidity control in automotive paint shops. Energy Conversion and Management, 261, 115654. https://doi.org/10.1016/j.enconman.2022.115654. Goedkoop, M., Heijungs, R., Huijbregts, M., De Schryver, A., Struijs, J., van Zelm, R., 2013. ReCiPe 2008, A life cycle impact assessment method which comprises harmonised category indicators at the midpoint and the endpoint level. Ministerie van VROM Rijnstraat. ILCD, 2010 a. Analysis of existing Environmental Impact Assessment methodologies for use in Life Cycle Assessment. Background document. European Commission. Joint Research Centre. Institute for Environment and Sustainability. ILCD, 2010 b. Framework and requirements for Life Cycle Impact Assessment models and indicators. European Commission. Joint Research Centre. Institute for Environment and Sustainability. INE, Instituto Nacional de Estadística. Inflation rate data from the last ten years. 2017. Available at http://www.ine.es/jaxiT3/Tabla.htm?t=22344. (Last access 06/2017). Integrated Environmental Authorization, 2014. Resolución de 7 de enero de 2014, del Instituto Aragonés de Gestión Ambiental, por la que se actualiza la autorización ambiental integrada de la planta de fabricación de vehículos a motor, ubicada en el polígono Entrerríos, en los términos municipales de Figueruelas y Pedrola (Zaragoza), y promovida por General Motors España, S.L.U. (Número Expte. INAGA 500301/02/2012/2990). Boletín Oficial de Aragón. ISO 14040:2006 Environmental management. Life cycle assessment, Principles and framework, 2006. International Organisation Standardisation. ISO 14044:2006 Environmental management. Life cycle assessment, Requirements and guidelines, 2006. International Organisation Standardisation. ISO 14045:2012 Environmental management. Eco-efficiency assessment of product systems. Principles, requirements and guidelines, 2012. International Organisation Standardisation. Jurgetz, A., 1995. Automotive paint performance. Met. Finish, 93, 53–55. https://doi.org/10.1016/0026-0576(96)80432-6. Kim, J-A., Kim, S., Kim, H-J., Kim, Y-S., 2011. Evaluation of formaldehyde and VOCs emission factors from paints in a small chamber: The effects of preconditioning time and coating weight. Journal of Hazardous Materials, 187 1-3, 52-57. https://doi.org/10.1016/j.jhazmat.2010.10.094. DANIEL GRANADERO REY 120 Klöpffer, W., Grahl, B., 2014. Life Cycle Assessment (LCA): A Guide to Best Practice. Life Cycle Assess. A Guid. to Best Pract. 1–396. https://doi.org/10.1002/9783527655625. Li, D., Wang, L., Lu, Y., Deng, H., Zhang, Z., Wang, Y., Ma, Y., Pan, T., Zhao, Q., Shan, Y., Shi, X., Ma, J., He, H., 2023. New insights into the catalytic mechanism of VOCs abatement over Pt/Beta with active sites regulated by zeolite acidity. Applied Catalysis B: Environmental, 334, 122811. https://doi.org/10.1016/j.apcatb.2023.122811. Marder, A. R., Goodwin, F. E., 2023. Chapter 12 - Zn-coated steel product properties. In Woodhead Publishing Series in Metals and Surface Engineering, The Metallurgy of Zinc Coated Steels, Elsevier. 397-455. https://doi.org/10.1016/B978-0-323-99984-7.00014-2. McMahon, M. E., Kammrath, B. W., Bender, L. (B-C.), 2023. Automotive Paint. Encyclopedia of Forensic Sciences, Third Edition. Elsevier, 1, 240-252. https://doi.org/10.1016/B978- 0-12-823677-2.00221-X. Mulholland, K. L., Dyer J.A., 1999. Pollution prevention: methodology, technologies, and practices. American Institute of Chemical Engineers. Nair K, S., Manu, B., Azhoni, A., 2021. Sustainable treatment of paint industry wastewater: Current techniques and challenges, Journal of Environmental Management, 296, 113105. https://doi.org/10.1016/j.jenvman.2021.113105. Nayane de Queiroz, M., de Oliveira Lima, A. M., Gomez Winkler, M. E., Hafemann Fragal, V., Forti Rubira, A., Sequinel, T., da Silva Ribeiro, L., de Souza Neto, F. N., Rodrigues Camargo, E., Ferreira Arlindo, M. Z., Saraiva Ogrodowski, C., Gorup, L. Z., 2022. Chapter 20 - Conductive nanopaints: A remarkable coating, In Micro and Nano Technologies, Nanotechnology in the Automotive Industry. Elsevier. 429-449. https://doi.org/10.1016/B978-0-323-90524-4.00020-7. Omar, M. A., 2011. The automotive body manufacturing systems and process. WILEY. UK. 2- 5:15-233. OMIP. Natural gas price 2018. Available at http://www.omip.pt/ (Last access 06/2017). Onofre A., Godina, R., Carvalho, H., Catarino, I., 2020. Eco-innovation in the cleaning process: An application of dry ice blasting in automotive painting industry. Journal of Cleaner Production, 272, 122987. https://doi.org/10.1016/j.jclepro.2020.122987. Ou, R., Chang, C., Zeng, Y., Zhang, X., Fu, M., Fan, L., Chen, P., Ye, D., 2022. Emission characteristics and ozone formation potentials of VOCs from ultra-low-emission waterborne automotive painting. Chemosphere, 305, 135469. https://doi.org/10.1016/j.chemosphere.2022.135469. Pizzi, A., Ibeh, C. C., 2022. Chapter 4 – Aminoresins. Handbook of Thermoset Plastics (Fourth Edition), William Andrew Publishing, 65-82. https://doi.org/10.1016/B978-0-12- 821632-3.00003-8. Poth, U., 2008. Automotive Coatings Formulation: Chemistry. Physics und Practices. References 121 Ramírez-Melgarejo, M., Güereca, L. P., Gassó-Domingo, S., Salgado, C. D., Reyes-Figueroa, A. D., 2021. Eco-efficiency evaluation in wastewater treatment plants considering greenhouse gas emissions through the data envelopment analysis-tolerance model. Environ Monit Assess, 193, 301. https://doi.org/10.1007/s10661-021-09063-5. Regulation (EC) No 1907/2006 of the European Parliament and of the council of 18 December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), establishing a European Chemicals Agency, amending Directive 1999/45/EC and repealing Council Regulation (EEC) No 793/93 and Commission Regulation (EC) No 1488/94 as well as Council Directive 76/769/EEC and Commission Directives 91/155/EEC, 93/67/EEC, 93/105/EC and 2000/21/EC, 2006. Official Journal of the European Union. Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006, 2008. Official Journal of the European Union. http://data.europa.eu/eli/reg/2008/1272/oj. Regulation (EU) No 605/2014 of 5 June 2014 (“6. ATP”) amending, for the purposes of introducing hazard and precautionary statements in the Croatian language and its adaptation to technical and scientific progress, Regulation (EC) No 1272/2008 of the European Parliament and of the Council on classification, labelling and packaging of substances and mixtures, 2014. Official Journal of the European Union. http://data.europa.eu/eli/reg/2014/605/oj. Regulation (EU) No 2015/491 of the European Parliament and of the Council of 23 March de 2015 amending Regulation (EU) No 605/2014 amending, for the purposes of introducing hazard and precautionary statements in the Croatian language and its adaptation to technical and scientific progress, Regulation (EC) No 1272/2008 of the European Parliament and of the Council on classification, labelling and packaging of substances and mixtures, 2015. Official Journal of the European Union. http://data.europa.eu/eli/reg/2015/491/oj. Rivera, J. L., Reyes-Carrillo, T., 2014. A Framework for Environmental and Energy Analysis of the Automobile Painting Process. Procedia CIRP, 15, 171-175. https://doi.org/10.1016/j.procir.2014.06.022. Rivera, J. L., Reyes-Carrillo, T., 2016. A life cycle assessment framework for the evaluation of automobile paint shops. Journal of Cleaner Production, 115, 75-87. https://doi.org/10.1016/j.jclepro.2015.12.027. Roth, L. and Rupp, G., 2014. Formaldehyd. Ecomed sicherheit. Germany.1:9-19. Salthammer, T., 2019. Formaldehyde sources, formaldehyde concentrations and air exchange rates in European housings. Building and Environment, 150, 219-232. https://doi.org/10.1016/j.buildenv.2018.12.042. DANIEL GRANADERO REY 122 Salthammer, T., Mentese, S., Marutzky, R., 2010. Formaldehyde in the Indoor Environment. Chem. Rev, 110, 2536. https://doi.org/10.1021/CR800399G. Silva Cavalcante, E., Sales Vasconcelos, L. G., de Farias Neto, G. W., Brandão Ramos, W., Pereira Brito, R., 2020. Automotive painting process: Minimizing energy consumption by using adjusted convective heat transfer coefficients. Progress in Organic Coatings, 140, 105479. https://doi.org/10.1016/j.porgcoat.2019.105479. Shamoon, A., Haleem, A., Bahl, S., Javaid M., Garg, S. B., Sharma, R.C., Garg, J., 2022. Environmental impact of energy production and extraction of materials - a review. Materials Today: Proceedings, 57-2, 936-941. https://doi.org/10.1016/j.matpr.2022.03.159. Shi, Y., Xi, Y., Lv, D., Simayi, M., Liang, Y., Ren, J., Xie, S., 2023. Sector-based volatile organic compound emission characteristics and reduction perspectives for coating materials manufacturing in China. Journal of Cleaner Production, 394, 136407. https://doi.org/10.1016/j.jclepro.2023.136407. Skone, T. J., Littlefield, J., Marriott, J., Cooney, G., Demetrion, L., Jamieson, M., Jones, C., Mutchek, M., Shih, C. Y., Schivley, G., Krynock, M., 2016. Life Cycle Analysis of Natural Gas Extraction and Power Generation. U.S. Department of Energy, 1-79. https://doi.org/10.2172/1480993. Sorrels, J. L., Baynham, A., Randall, D., Hancy, C., 2017. Incinerators and Oxidizers. U.S. Environmental Protection Agency (EPA), Research Triangle Park, NC 27711, 1-70. Stoye D., 1993. Paints, coatings and solvents. VCH. Germany. Stoye, D., Freitag, W., 1998. Paints, coatings and solvents. (ed.). - 2. completely rev. ed; Wiley- VCH. Streitberger, H-J., Dössel, K-F., 2008. Automotive Paints and Coatings. Second, Completely Revised and Extended Edition; Wiley-VCH. STS BREF. European Commission, Joint Research Centre (JRC), Chronopoulos G., Cakmak G-E., Tempany P., Klein G., Brinkmann T., Zerger B., Roudier S., 2020. Best available techniques (BAT) reference document on surface treatment using organic solvents including preservation of wood and wood products with chemicals: Industrial Emissions Directive 2010/75/EU (integrated pollution prevention and control). Publications Office. .https://data.europa.eu/doi/10.2760/857. Tomatis, M., Moreira, M. T., Xu, H., Deng, W., He, J., Parvez A. M., 2019. Removal of VOCs from waste gases using various thermal oxidizers: A comparative study based on life cycle assessment and cost analysis in China. Journal of Cleaner Production, 233, 808- 818. https://doi.org/10.1016/j.jclepro.2019.06.131. Torregrossa, D., Leopold, U., Hernández-Sancho, F., Hansen, J., 2018. Machine learning for energy cost modelling in wastewater treatment plants. Journal of Environmental Management, 223, 1061-1067. https://doi.org/10.1016/j.jenvman.2018.06.092. References 123 VDA Internal information for members of Working Group Industrial Emissions, 2015. VDI 3862 Part 2:2000-12. VDI/DIN-Kommission Reinhaltung der Luft (KRdL) – Normenausschuss, 2000. Gaseous emission measurement - Measurement of aliphatic and aromatic aldeydes and ketones by DNPH method - Impinger method. VDI guideline 3455:2013-08. VDI/DIN-Kommission Reinhaltung der Luft (KRdL) – Normenausschuss, 2013. Emission control. High-volume car body painting plants. Verbände-Positionspapier zur Neu-Einstufung von Formaldehyd in die TA Luf, 2014. Verband der Chemischen Industrie e.V. und Verband Textil-Bekleidung. Wicks Z.W, Jones F.N., Pappas S.P., Wicks D.a. (2007). Organic coatings: Science and technology. 3° Ed. WILEY-INTERSCIENCE. New Jersey.8: 159-166; 10-11: 200-229. Wilson, J. B., 2009. Resins: A Life-Cycle Inventory of Manufacturing Resins Used in the Wood Composites Industry. Department of Wood Science and Engineering, Oregon State University, Corvallis, OR 97331-5751. Xu, J., Tai, X., Betha, R., He, J., Balasubramanian, R., 2015. Comparison of physical and chemical properties of ambient aerosols during the 2009 haze and non-haze periods in Southeast Asia. Environ Geochem Health 37, 831–841. https://doi.org/10.1007/s10653- 014-9667-7. Xu, J., Xu, H., Xiao, H., Tong, L., Snape, E., Wang, C., He, J., 2016. Aerosol composition and sources during high and low pollution periods in Ningbo, China. Atmospheric Research, 178-179, 559-569. https://doi.org/10.1016/j.atmosres.2016.05.006. Yang, C., Miao, G., Pi, Y., Xia, Q., Wu, J., Li, Y., Xiao, J., 2019. Abatement of various types of VOCs by adsorption/catalytic oxidation: A review. Chemical Engineering Journal, 370, 1128-1153. https://doi.org/10.1016/j.cej.2019.03.232. LIST OF TABLES Table 1. Collection of paint shop conditions – survey data. Table 2. Typical formaldehyde concentrations in vehicle paints. Table 3. Comparison of the main characteristics of the two alternative abatement systems. Table 4. Measurement program for paint shop 1. Table 5. Measurement program for paint shop 2. Table 6. Measurement program for paint shop 3. Table 7. Measurement program for paint shop 4. Table 8. Measurement program for paint shop 5. Table 9. Measurement program for paint shop 6. Table 10. Measurement results for paint shop 1. Table 11. Measurement results for paint shop 2. Table 12. Measurement results for paint shop 3. Table 13. Measurement results of primer oven abatement systems at different temperatures. Table 14. Measurement results for paint shop 4. Table 15. Measurement results for paint shop 5. Table 16. Measurement results for paint shop 6. Table 17. Inventory of formaldehyde emissions for LCA. Table18. LCI for the electrocoating process. Table 19. LCI for primer process. Table 20. LCI for the topcoat process. DANIEL GRANADERO REY 132 Table 21. LCI for the painting process. Table 22. LCI modifications for the studied scenarios. Table 23. Variation in percentage of the characterization results for all impact categories in the Scenarios B and C with regard to Scenario A for the topcoat process. Table 24. Implementation costs for RTO and Recuperative Thermal Oxidizers. LIST OF APPENDIXES Section affected by copyright protection. PUBLICATIONS Evaluation of abatement options to reduce formaldehyde emissions in vehicle assembly paint shops using the Life Cycle methodology Daniel Granaderoa b *, Aida Garcia-Muñozb, Renate Adamb, Francisco Omila and Gumersindo Feijooa a CRETUS, Department of Chemical Engineering, School of Engineering, Universidade de Santiago de Compostela, 15782, Santiago de Compostela, Spain b Environmental Compliance and Sustainability, Stellantis, 65423, Rüsselsheim am Main, Germany Cleaner Environmental Systems. ISSN: 2666-7894, Volume 11, 100139, 2023. https://doi.org/10.1016/j.cesys.2023.100139. Specific contribution to the publication Daniel Granadero performed the methodology, formal analysis, investigation, writing – original draft and visualization of this research article. Quality indicator The Journal Cleaner Environmental Systems currently presents an impact factor of 5 (2022 Journal Citation Reports), a Cite Score Index of 4.6 (according to Scopus, 5.05.2023) and the following positions in the different categories: quartile 1 (Q1) in “Environmental Science - miscellaneous” (40/163), quartile 2 (Q2) in “Environmental Science - Management, Monitoring, Policy and Law” (125/384), quartile 2 (Q2) in “Environmental Science - Environmental Engineering” (68/184) and quartile 3 (Q3) in “Energy - Renewable Energy, Sustainability and the Environment” (120/235). DANIEL GRANADERO REY 136 Authorization to the use of this article in this Ph.D. thesis Cover of the article This Ph.D. thesis assesses the impact of the change in the hazardous classification of formaldehyde in vehicle paint shops from an environmental and economic perspective. This work includes an evaluation of compliance with the applicable emission limit value for formaldehyde, a proposal of options to reduce the emissions and their economic impact, a Life Cycle Assessment of the painting process in a real vehicle paint shop and an eco-efficiency analysis. The outcomes of this thesis allowed to make a proposal for the most eco-efficient vehicle paint shop in view of formaldehyde emissions performance.