Production of radiotracers for medical imaging using laser-acceleration techniques
Abstract
The objective of the doctoral thesis is to study whether the acceleration of laser-induced particles can be a competitive option for the production of positron-emitting radiotracers. To do this, an experimental work is proposed using the laser of the Laboratorio Láser de Aceleración y Aplicaciones (L2A2) of the Universidad de Santiago de Compostela. This work will consist of putting into operation the necessary technology to accelerate a sufficient and continuous amount of protons or deuterons with energies of up to 10 MeV.
Full text
INTERNATIONAL DOCTORAL SCHOOL OF THE USC Juan Peñas Nadales PhD Thesis Production of radiotracers for medical imaging using laser-acceleration techniques Santiago, 2023 Programa de doctorado en Física de Partículas
Universidad de Santiago de Compostela Departamento de Física de Partículas Production of radiotracers for medical imaging using laser-acceleration techniques Author: Juan PEÑAS NADALES Supervisor: Dr. José Fernando BENLLIURE ANAYA May 21, 2023
ii
UNIVERSIDADE DE SANTIAGO DE COMPOSTELA Dr. José Fernando BENLLIURE ANAYA, PROFESOR DEL DEPARTAMENTO DE FISICA DE PARTICULAS DE LA UNIVERSIDAD DE SANTIAGO DE COMPOSTELA, CERTIFICA: que la memoria titulada: Production of radiotracers for medical imaging using laser acceleration techniques fue realizada por Juan PEÑAS NADALES en el Departamento de Física de Partículas de la Universidad de Santiago de Compostela bajo su dirección, y constituye el trabajo de tesis que presenta para optar al grado de Doctor en Ciencias Físicas. Santiago de Compostela, May 21, 2023 Dr. José Fernando BENLLIURE ANAYA Departamento de Física de Partículas
v “Once he wore grey, he fell and slipped away, from everybody’s sight. The wizard of them all, came back from his fall, this time wearing white.” Camel, The White Rider
vii UNIVERSIDADE DE SANTIAGO DE COMPOSTELA Abstract Facultad de Física Dpto. de Física de Partículas Doctor of Physics Production of radiotracers for medical imaging using laser acceleration techniques by Juan PEÑAS NADALES The objective of the doctoral thesis is to study whether the acceleration of laser-induced particles can be a competitive option for the production of positron-emitting radiotracers. To do this, an experimental work is proposed using the laser of the Laboratorio Láser de Aceleración y Aplicaciones (L2A2) of the Universidad de Santiago de Compostela. This work will consist of putting into operation the necessary technology to accelerate a sufficient and continuous amount of protons or deuterons with energies of up to 10 MeV.
xv List of Figures 2.1 TNSA ....................................... 19 2.2 SimTNSA ..................................... 21 2.3 PETXsec ..................................... 28 2.4 TempProd ..................................... 32 3.1 CPA ........................................ 34 3.2 PulseT ....................................... 35 3.3 STELA ...................................... 38 3.4 STELActr ..................................... 39 3.5 LsScVEGA .................................... 40 3.6 VEGActr ..................................... 41 3.7 MCPSc ...................................... 43 3.8 ToFEx ....................................... 45 3.9 TPSc ........................................ 47 3.10 PICSch ...................................... 52 4.1 WhEvol ...................................... 57 4.2 TarWh ....................................... 58 4.3 TarAssembly ................................... 59 4.4 WMaps ...................................... 60 4.5 CoordConv .................................... 62 4.6 DefSch ...................................... 64 4.7 SnsrTst ...................................... 67 4.8 CuStU ....................................... 68 4.9 CuCorr ...................................... 68 4.10 ValSch ....................................... 70 4.11 ValMap ...................................... 71
xvi 4.12 IntP ........................................ 72 4.13 CalI ........................................ 73 4.14 SatI ........................................ 74 4.15 Comp ....................................... 75 4.16 Comp2 ....................................... 76 4.17 WhCorr ...................................... 77 4.18 WhCLPUCorr ................................... 78 4.19 ShotOrd ...................................... 80 5.1 ChamberScheme ................................. 84 5.2 Spckle ....................................... 86 5.3 FocL2A2 ..................................... 87 5.4 TriggL2A2 .................................... 88 5.5 TriggL2A2 .................................... 88 5.6 ProtSp ....................................... 90 5.7 STarg ....................................... 93 5.8 EstL2A2 ...................................... 94 5.9 TEstL2A2 ..................................... 96 5.10 ChCLPU ..................................... 97 5.11 CLPURef ..................................... 100 5.12 TriggCLPU .................................... 102 5.13 IonC ........................................ 104 5.14 SpTP ....................................... 105 5.15 SpToF ....................................... 106 5.16 ScAll ....................................... 108 5.17 AngComp ..................................... 110 5.18 Evol ........................................ 111 5.19 FocCLPU ..................................... 113 5.20 TEmSc ...................................... 114 5.21 StabCLPU ..................................... 116 5.22 TStabCLPU .................................... 118 5.23 SimEx ....................................... 122 5.24 SThick ....................................... 124 5.25 SFI ......................................... 125
xvii 5.26 CLPUSim ..................................... 127 5.27 SEner ....................................... 128 5.28 LitScal ....................................... 132 6.1 DetDev ...................................... 138 6.2 ExSimSp ..................................... 141 6.3 EffComp ...................................... 142 6.4 EffSour ...................................... 143 6.5 ActDEx ...................................... 144 6.6 ChProd ...................................... 145 6.7 ChProd2 ...................................... 146 6.8 11CSp ....................................... 147 6.9 CoincSch ..................................... 148 6.10 RProtB ...................................... 150 6.11 NCalIn ....................................... 152 6.12 NCalG ....................................... 153 6.13 NCalR ....................................... 154 6.14 ActT ........................................ 155
xix List of Tables 2.1 Nuclear reactions of interest for the production of radioisotopes used in PET. Dash lines indicate a energy threshold below 1 MeV. .............. 27 4.1 Calibration curves fit parameters. Linear fit: RMS =mf +n; parabolic fit: RMS =af2+bf +c.............................. 74 5.1 Spectral parameters for the base and corrected energy distributions. ....... 92 5.2 Maximum energies in MeV measured by the TP and the two ToF detectors at 18/10/22. ..................................... 109 5.3 Maximum energies in MeV measured by the TP and the two ToF detectors at 21/10/22. ..................................... 109 5.4 Correlation between the maximum energy and the temperature. ......... 115 5.5 Parameters for the laser-driven proton acceleration simulations, performed by means of the Smilei code, for the cases at L2A2 and CLPU. ........... 119 5.6 Comparison of the cut-off energy and the temperature between experiment and simulation. *: data from a different day. ..................... 126 5.7 Main experimental parameters of published data reviewed in this work. From left to right: pulse energy, pulse duration, focus spot size, wavelength, peak intensity, dimensionless laser amplitude, protons maximum energy, target material, target thickness and laser contrast. For those references with spectra measured for different experimental conditions it is shown the case with the highest cut-off energy. Values denoted with a hyphen are not specified in the original study. ................................... 130 6.1 Experimental parameters and 11C production results for each irradiation series. 146 6.2 Proton spectral calibration (base spectrum) for N0(a.u.) = 1·1010........ 153
xxi List of Abbreviations ASE Amplified Spontaneous Emission BR Branching Ratio CPA Chirped-Pulse Amplification EM,EMP Electromagnetic Pulse FWHM Full-Width at Half Maximum IP Image Plate IR Infrared MCP Micro-Channel Plate MEMS Micro-Electromechanical System OAP Off-Axis Parabola OD Optical Density (filter) PET Positron Emission Tomography PIC Particle-In-Cell PMT Photomultiplier RCF Radio-Chromic Film RF Radio-Freqcuency RMS Root-Mean Square RPA Radiation Pressure Acceleration SPECT Single-Photon Emission Computed Tomography TCC Target Chamber Centre TNSA Target Normal Sheath Acceleration ToF Time-of-Flight TP Thomson Parabola TTL Transistor-Transistor Logic XPW Cross-Polarised Wave
xxiii Physical Constants Speed of Light c= 2.997 924 58 ×108m/s(exact) Elemental charge e=q= 1.6×10−19 C Electron mass me= 0.511 MeV Proton mass mp= 931 MeV Avogadro constant NA= 6.02 ×1023 1/mol Vacuum permittivity 0= 8.85 ×10−12 F/m Boltzmann constant kB= 8.62 ×10−5eV/K Bohr radius aB= 0.53 ×10−10 m Reduced Plank constant ¯h=h/2π= 6.58 ×10−16 eV s
1.2. Structure of the thesis 3 cost-effectiveness, efficiency, and accessibility. 1.1.2 Objective of this thesis Following the aforementioned arguments, ultraintense lasers may constitute a appropriate alternative for the on-demand production of single doses of short-lived radioisotopes used in PET imaging. The aim of this doctoral thesis is to explore the potential of laser-driven particle acceleration as an efficient means of the production of these radioisotopes. Typical required doses for PET are in the range of 10 – 30 MBq for preclinical, and between 200 MBq and 1 GBq for clinical imaging, being the scope of this work situated at a preclinical level. Concretely, the focus of this study relies on the production of 11C through the proton-induced nuclear reaction 11C(p,n)11B using a proton beam from a laser-driven source. This includes the experimental characterisation of the production process as well as precise estimations and extrapolations for further investigations. For this purpose, the first step consisted on the development of an ion source matching the requirements in stability and sustained operation over time for radioisotope production. This involved the design and construction of a multi-shot target system capable of overcoming the mechanical challenges commonly found in laser-plasma interaction. The performance of the design proposed in this thesis was firstly evaluated as part of the current commissioning campaign at the Laser Laboratory for Acceleration and Applications (L2A2) in the Universidade de Santiago de Compostela (USC), and finally employed as the main ion source at an experimental campaign at the Centro de Láseres Pulsados (CLPU), focussed on neutron generation. The protons accelerated within the CLPU experiments were used to successfully produce and measure 11C activities by irradiating a boron target. The thesis also involves the simulation and modelling of the production process, as well as the several mechanisms that govern laser-target interaction and particle acceleration, for their proper understanding and optimisation. Overall, the outcome of this research could contribute to the development of a more cost-effective, efficient, and accessible method for the production of radioisotopes used in PET medical imaging. 1.2 Structure of the thesis The theoretical foundations and the current state-of-art that define the framework at which this thesis is enclosed are presented in Ch. 2. Within this chapter, the fundamentals on both
4Chapter 1. Introduction laser-driven particle acceleration and radioisotope production from a laser-accelerated ion source are presented. For the former, an overview of the principal mechanisms governing laser-plasma interactions that led to efficient electron and ion acceleration are detailed. Regarding the later, this chapter addresses the prevalent formalism for the induced production of radioisotopes and the characterisation of radioactive samples. The next chapter, Ch. 3, presents the methods, devices, and tools employed in this work. This includes a detailed description of the two laser systems where the experiments that comprise this thesis were performed (STELA and VEGA), the properties of the main detectors that were used within these experiments, and the principles and functioning of the numerical simulation codes for the analysis of the results. Ch. 4delves into the complete development of the multi-shot target system used at the experimental campaigns. A description of the assembly is firstly presented, along with the designed positioning and correction procedure and its implementation through a self-developed control software. The evaluation of the system performance, regarding its shot-to-shot stability and sustained operation over time, is then discussed and validated. The operation process within the experiments is also depicted. An entire chapter —Ch. 5— is dedicated to the experiments on laser-driven ion acceleration carried out within this work. This chapter is divided in four major parts: each of the two main experimental campaigns at which the author participated have a separate section, containing the description of the set-up and methodology, and an exposition of the obtained results; other section comprises the Particle-In-Cell numerical simulations performed in order to supplement the experimental data; the analysis and the comparison between results are finally presented in the last sections, focussing on the scaling of the main parameters characterising the accelerated ion beams with the laser and the target properties. In Ch. 6, radioisotope production from laser-accelerated protons is addressed. The target and diagnosis system, developed for the transmutation and activity characterisation of 11C from the proton-induced 11C(p,n)11B nuclear reaction, is described and depicted. Following the calibration of such system, the experimental arrangement and methodology are presented. The analysis of the activation results, as well as its comparison with recently published data and some future extrapolations, is given at the end of the chapter. Final conclusions are then presented in Ch. 7.
1.3. Role of the author 5 1.3 Role of the author The work presented in this thesis comprises the commissioning of an ion source at the L2A2, in a combined effort with the staff personnel and the researcher team. In particular, the author was mainly dedicated to the design of the multi-shot target system. A significant part of this work involved the complete development of the control software, which may not be reflected in this document but for a few mentions. Due to this facts, some of the contents of this document may appear rather technical, in comparison with other doctoral theses about the same topic. The expertise obtained within the development of the on-site laser-plasma ion source was used in an experimental campaign at the Centro de Láseres Pulsados (CLPU) laser facility. The multi-shot target system was employed as a laser-induced ion source for the experiment, which was focussed on neutron production. Several modifications and tests were performed by the author in order to adapt the target assembly and its operation procedure to the distinctive features of the CLPU facility, either before and during the experiment. The author was in charge of the proper functioning of the target assembly within the CLPU campaign. Along with the researcher and technical staff participating in the experiment, measurements on laser-driven ion acceleration could be performed. In addition, a device for the activation of 11C induced by laser-accelerated protons was designed at the L2A2 and mounted at the CLPU experiment. The operation of this system and the data acquisition relied on the author. Several particle and radiation detectors were calibrated for their use at the laser driven ion acceleration and radioisotope production experiments. For the former, a Time-of-Flight detector, developed at the Instituto de Instrumentación para Imagen Molecular (I3M), was calibrated at the Centro Nacional de Aceleradores (CNA) by researchers from both institutions and the author. The radiation detectors used for the radioisotope decay activity measurements were calibrated and characterised by the author by means of experimental analysis and Montecarlo simulations (EnsarROOT code). Regarding the data treatment, the author is responsible of the results presented in this work and their complete analysis, under the supervision of Dr. J. Benlliure and the assistance of Dr. A. Alejo. The author also performed several Particle-In-Cell (PIC) simulations in order to complement the experimental data. In particular, the Smilei code was used for the simulation of laser-plasma interaction and laser-induced ion acceleration.
7 Chapter 2 Background and state-of-art This chapter details the theoretical framework, as well as a summary of recently published data, about the topics of this thesis, in order to provide a solid background for the work presented here. Thus, this chapter serves as a means of understanding the underlying physics that dominate the interaction of ultraintense laser pulses with matter for ion acceleration, and the production of radioisotopes, in the context of PET medical imaging, from them. Sect. 2.1 introduces the context on the interaction of electromagnetic radiation with matter, and in particular, the effects of a intense electromagnetic pulses on a ionised plasma. The principal absorption mechanisms that govern the laser-plasma interaction and that lead to efficient electron acceleration are discussed in Sect. 2.2. Then, Sect. 2.3 details the main mechanisms of ion acceleration from laser-driven interaction. Regarding the ratioisotope production scope of this thesis, Sect. 2.4 summarises the processes that arise in the interaction of ionising radiation with matter, and finally a description of the physics involved in the induction of nuclear reactions from laseraccelerated ions is given in Sect. 2.5. 2.1 Laser-plasma interaction The properties of ultraintense ultra-short laser pulses will be described in detail in Ch. 3. For now, they will be simply defined as a finite huge electromagnetic oscillating field concentrated in an ultra-short pulse of several tens of femtoseconds to a few picoseconds and a micron-size area. The intensity of these laser pulses, defined as the energy density in time and space, can be estimated by equation
8Chapter 2. Background and state-of-art IL∼0c 2E2 0(2.1) where 0is the vacuum permittivity, cthe speed of light, and E0the amplitude of the electric field, given by expression E0=A0ωLfrom the amplitude of the vector potential A0and the oscillation frequency of the laser ωL. When a pulse having these properties impinges on a fluid or solid target, it ionises the atoms of the material leading to the formation of an underdense or overdense expanding plasma, respectively. Eq. 2.1 can be compared with the atomic intensity given by the atomic electric fields of the Coulomb potential. Considering the ionisation mechanism with the most simple description, barrier suppression ionisation(1), this intensity can be calculated from Eq. 2.1 and the definition of electric field from the Coulomb’s law Ia=0c 2E2 a=0c 2 e 4π0a2 B!2 (2.2) In this expression, aB=4π0¯h2 mec2corresponds to the Bohr’s radius of an atomic electron orbiting around the nucleus as described in the Bohr’s atomic model. Here, eis the elemental charge, ¯his the reduced Planck constant, and meis the electron mass. Thus, the intensity associated to the atomic electric field can be estimated to be of the order of 1015 – 1016 W/cm2. Laser pulses with intensities above this value will ionise the surface of the medium, hence generating a plasma of free —unbound— electrons and ions. The ponderomotive force The description of the effect of an intense and finite oscillating electromagnetic pulse on a plasma can be firstly understood by considering the simple case of a single electron. The temporal intensity profile of a laser pulse can be depicted as a Gaussian envelope with an internal oscillation given by its frequency. As will be seen in Ch. 3, the spatial intensity profile of a focussing laser pulse can be considered as a two-dimensional Gaussian as well, being more intense at the central point. A plasma electron, located at the centre of the laser focus and oscillating according to the field, is pushed away to regions of lower intensity during the first half-cycle of the laser pulse, i.e., the rise time of the Gaussian envelope. During the second half, the electron is accelerated in the opposite direction but, as the amplitude of laser pulse decreases
2.1. Laser-plasma interaction 9 over time, it experiences a reduced restoring force. This results in a net-positive acting force that is commonly referred as ponderomotive force[1,2]. It can be described in terms of the electric field gradient of the laser pulse as Fp=−e2 2meω2 L ∇E2 0(2.3) that, in regards to the pulse intensity from Eq. ??, can be expressed as Fp=−e2 me0cω2 L ∇IL(2.4) It can be seen at these expressions that the force is directed along the field gradient, the propagation direction, and proportional to the laser intensity. Hence, an electron located at a certain distance from the focal spot will experience a reduced force and will be pushed at a certain angle with respect to the propagation direction. A key of this process is the finite duration of the laser pulses. An infinite plane wave would not produce a net force on the electrons as they would return to their initial position after the oscillations, thus not gaining net energy. For the relativistic regime, above 1018 W/cm2, the ponderomotive force definition can be updated by including the Lorentz relativistic factor γ−1=√1−β2. Propagation of a laser pulse in a plasma In the real experimental case, the pedestal of the laser pulses preceding the main peak (see Fig. 3.2 in Ch. 3) produces an expanding plasma that, through the interaction with the main pulse, leads to the efficient acceleration of electrons. This preplasma spreads at a velocity given by the sound speed of the ions cs=sZikBTe mi (2.5) being Ziand mithe ion charge state and mass, respectively, kBthe Boltzmann constant, and Tethe hot electron temperature. For the relativistic regime, this temperature can be roughly estimated to be equal to the ponderomotive potential[3,4]. Assuming the poderomotive force is a conservative force, as it can be expressed in terms of a gradient, this potential Upcan be calculated from Eq. 2.3 as
10 Chapter 2. Background and state-of-art kBTe∼Up=e2E2 0 2meω2 Lγ=mec2q1 + a2 0−1(2.6) a0= 0.85v u u t ILλ2 L 1018 W cm−2µm2(2.7) In this expression, ILis introduced in W/cm2units and λLis the laser wavelength in µm. The parameter a0, formally called the dimensionless amplitude, determines the regime of the interaction. The relativistic limit is set at a0= 1, corresponding to ∼1018 W/cm2for a typical 800 nm laser system, above which the interaction can be considered as relativistic, whereas for a0<1it can be treated as classical. The expanding plasma exhibits a density profile that grows close to the target surface. Assuming isothermal expansion, this density profile necan be described in good approximation by a exponential distribution along the propagation direction zas ne(z)∝exp(z/Lg)(2.8) where Lgis called plasma scale-length and is defined as the distance at which the plasma density is 1/e of its initial value. Other variations of this profile have been explored in literature, as for example linear and parabolic shapes[5] or an smoothed exponential ne∝[tanh( z Lg) + 1]. Following the isothermal assumption, the scale-length can be estimated from the ion sound speed (Eq. 2.5) and the duration of the pulse pedestal τASE Lg≈csτASE (2.9) In some other cases, the duration of the laser pulse or the anticipation time with respect to the main pulse of the prepulses above the ionisation threshold, if any, can be used for calculating this parameter. As the main pulse reaches the preplasma, it can only penetrate if its oscillation frequency satisfies the propagation condition ωL> ωp, obtained from the evaluation of Maxwell’s equations. The parameter ωpis the plasma frequency of the electrons, whose definition is
2.2. Absorption mechanisms 11 ωp=snee2 me0 (2.10) where neis the density of the free electrons in the plasma. If the laser frequency is lower than the plasma frequency, the electrons are able to oscillate at such frequency and thus compensate the electric field. In this way, the energy from the laser pulse is dissipated in the plasma. If the laser frequency is higher, on the contrary, the electrons only "see" the Gaussian envelope instead of the oscillation, leading to their effective acceleration. This can be also explained in terms of the refractive index ηof the plasma medium, given by expression η=v u u t1−ω2 p ω2 L =s1−ne nc (2.11) If the propagation condition is satisfied, the refractive index has a real value and the wave can propagate along the medium. On the contrary, if the condition is not satisfied, the refractive index becomes pure imaginary and the electromagnetic pulse is either absorbed or reflected at the plasma front. The parameter ncin this equation is defined as the critical density at which ωL=ωp. As the pulse propagates through the preplasma, the electrons are pushed due to the ponderomotive force towards the target. This leads to a density wave propagating along the plasma density profile with increasing amplitude over time, as more electrons are concentrated at the wavefront. For the case of solid targets, the main pulse follows the density wave until it reaches the critical density. Then, the pulse cannot propagate further and is mostly reflected. The accelerated electrons, on the contrary, are injected into the target. 2.2 Absorption mechanisms As indicated in previous section, the incidence of a ultraintense ultra-short laser pulse at a solid target produces an expanding plasma where the electrons are accelerated. Several acceleration mechanisms that let the energy gain by the electrons can occur at the critical density limit, depending on both laser and target properties. These properties, as for example the pulse intensity, the angle of incidence, or the laser polarisation, will favour one or multiple acceleration mechanisms. Throughout this section, several mentions to the laser polarisation will be made.
12 Chapter 2. Background and state-of-art In particular, p- or s-polarisation, which are two types of linear polarisation of the laser electric field. In the context of a laser pulse impinging on a solid target at a certain incidence angle, ppolarisation implies that a component of the electric field is perpendicular to the target surface, that is, parallel to the density gradient of the preplasma. In s-polarisation, on the contrary, the field oscillation is parallel to the target surface. Some of the mechanisms described in this section are predominant at moderate intensities, i.e., below a0= 1. While the laser systems employed in the experimental part of this thesis are mostly relativistic (a0ranging between 1 and 10), these mechanisms are in principle not relevant. However, a brief description of them will be provided as they dominate the interaction of the laser pedestal with the targets, that produces the formation of the preplasma. For the following, only the interaction of a laser pulse with a solid target, hence an overdense plasma, will be considered. Other mechanisms for the efficient acceleration of electrons dominate the interaction of an underdense plasma and a laser pulse, as for example wakefield acceleration[6, 7]. Since no experiments were performed using gaseous or liquid targets, these mechanisms are not relevant in the scope of this thesis. 2.2.1 Moderate-intensity mechanisms Resonant absorption Resonant absorption[6,8] is the principal collision-less mechanism for the electron acceleration at moderate intensities. It occurs for laser pulses incident at a certain non-zero angle with respect to the target normal, and p-polarisation. This conditions guarantee that a component of the electric field oscillates in the same direction as the density gradient at the target surface (E·∇n6= 0). The plasma electrons then follows the oscillation and a density wave —also called Langmuir wave— is generated at ωL. At the critical surface, where ne=nc, this density wave is excited to a resonance at this frequency and a significant fraction of the laser energy is transferred to the electrons. This fraction can be estimated from expression[1] fRA ≈1.15τ2exp −4τ3 3!(2.12)
2.3. Ion acceleration mechanisms 19 for the acceleration of ions from these hot electrons, only Target Normal Sheath Acceleration (TNSA) is relevant within this thesis. Other processes, such as Radiation Pressure Acceleration (RPA)(1,2), Hole Boring(3,4), Light Sail(5), or Collisionless Shock Acceleration (CSA)(6) take place at higher intensities (1020 – 1022 W/cm2) and not applicable for the laser systems used in this work. An in-depth understanding of these mechanisms can be found in recent reviews on laser-driven ion acceleration[29,6]. 2.3.1 Target Normal Sheath Acceleration Target Normal Sheath Acceleration (TNSA)[21,33,34] is the most studied and extended ion acceleration mechanism, as it provides a robust and efficient means to produce high-energy ion beams up to tens of MeV. In addition, its range of applicability covers a wide number of situations regarding laser and target parameters. It emerges from the interaction of an ultraintense laser pulse of IL> 1018 W/cm2with a thin solid foil of micron-size thickness. e- + + + + - - - - - Laser pulse Preplasma Electron sheath Ion front Solid target FIGURE 2.1: Schematic representation of the TNSA mechanism. A basic scheme of TNSA is illustrated in Fig. 2.1. As the laser pulse impinges on the solid target, the pedestal preceding the main peak ionises the surface leading to an expanding plasma. From the interaction of the main pulse and the plasma, a relativistic electron beam is accelerated according to the mechanisms described, and injected into the target. If the electrons are enough energetic, they can traverse the target foil and emerge at the rear side as an expanding sheath.
20 Chapter 2. Background and state-of-art The charge-separation electric field that is generated between the sheath and the positive ions from the target surface is strong enough (∼TV/m) to deflect the less energetic electrons back to the target, which then recirculate as returning currents. Unless specifically removed, the target foils used in laser-driven ion acceleration typically have a contaminant layer covering their surfaces, mainly composed of water vapour and hydrocarbons. The huge electrostatic electric field generated by the electron sheath is then able to ionise the material of these contaminants and pull the ions towards the direction normal to the target surface. A bunch of ions is in this way accelerated following the expansion of the electron sheath up to MeV-order energies. Due to their lighter mass and higher charge-to-mass ratio, protons are more efficiently accelerated and thus dominate the ionic composition of the resulting beam. Other heavier ions in different ionisation degrees, such as carbon, nitrogen, or oxygen, are also accelerated. This charge imbalance also occurs at the frontal surface of the target, due to the expansion of the preplasma. Thus, electron and ion acceleration is also produced, but is typically less efficient than at the rear side. Fig. 2.2 depicts the evolution of the electron and proton densities (red and green curves), and the electric field (blue curve) during the last phase of TNSA, obtained from one-dimensional Particle-In-Cell simulations. The figure shows the rear side of a slab target at four different times after the formation of the electron sheath. The densities are normalised to the critical density, the spatial dimension to the laser wavelength, and the electric field to the laser amplitude. It can be seen that the electric field produced by the electron distribution peaks at the expanding ion front, producing a huge electrostatic pull on them at each time instant. Analytically, the TNSA mechanism can be effectively described by a self-similar, isothermal expansion model formulated by P. Mora in [35]. It provides a one-dimensional description of the temporal evolution of the accelerated ions and the charge-separation field in terms of parameters both from the laser and the target. This model assumes that the hot temperature of the electron sheath remains constant during the acceleration process due to the short, picosecond temporal scale at which it occurs. It also imposes the quasi-neutrality of the expanding plasma at the rear side of the target: ne=Zini, where neand niare the electron and ion densities, respectively, and Zithe ion state of charge. A step-by-step derivation of the model can be found in [35,21]. From the evaluation of the Poisson’s equation at the sheath-vacuum interface an electron energy distribution as depicted in Eq. 2.16 can be obtained. From a classical point of view, the
2.3. Ion acceleration mechanisms 21 FIGURE 2.2: Evolution of the electron and proton densities, and the electrif field, from 1D PIC simulations. broadening of the electron distribution to a Maxwellian dependence is explained by binary collisions with the plasma particles as they are injected into the target. In this case, the distribution amplitude ne0can be updated from Eq. 2.24 to consider the angular spread of the electron beam while traversing the target foil, as ne0=fJBEL cτLSskBTe (2.25) where Ss=π(r0+Dtan(θe/2))2is the area of the electron sheath, defined by the target thickness Dand the angular divergence θeof the electrons inside the target. For foils thinner than 10 µm this angle can be taken as θe∼16 – 25◦[18]. From the electron spectral distribution and the quasi-neutrality condition, the density distribution in terms of the energy of the ion front expanding at a velocity given by the ion sound
22 Chapter 2. Background and state-of-art speed (Eq. 2.5) can be obtained as dNi=N0 √2ZikBTeEi e−q2Ei ZikBTedEi(2.26) which corresponds to a Maxwell-Boltzmann distribution. The parameter N0=n0ecstSsis the distribution amplitude in number of particles per unit of energy at a given time t,Teis again the hot electron temperature, and Eithe ion energy. The isothermal model is valid for a t> 0 that in first approximation it can be estimated to be comparable to the pulse duration τL(fs – ps). This restriction is introduced ad hoc in the model formulation in order to avoid an infinite energy gain by the ions with time. A more detailed description leads to an empirical expression for the acceleration time in terms of the laser intensity, as introduced by [18] tacc ≈[−6.07 ·10−20(IL−2·1018) + 3] ·(τL+tmin)(2.27) for 2·1018 ≤IL≤3·1019 W/cm2, and tacc ≈1.3(τL+tmin)(2.28) for IL>3·1019 W/cm2. In these expressions, tmin is defined as the minimum time that the ions need to absorb energy from the electrons. This time was found to be around 60 fs for laser pulse durations below 100 fs[18]. The separation of the acceleration time in two regimes given by Eqs. 2.27 and 2.28 take into consideration that for lower intensities the expansion time is in principle slower, so the acceleration time must be longer. From the definition of the normalised acceleration time τ=ωpitacc/q2 exp(1), being ωpi = qne0Zie2/mi0the ion plasma frequency, the model also predicts a maximum, or cut-off energy gained by the ions, given by Emax = 2kBTe[ln(τ+√τ2+ 1)]2(2.29) As shown, for intensities above 1018 W/cm2,J×Bheating is the predominant acceleration for electron acceleration. The ponderomotive potential provides a scaling for the hot temperature proportional to a0, as in Eq. 2.23, in the order of several MeV. Considering the relation between
2.3. Ion acceleration mechanisms 23 the temperature and the cut-off energy in Eq. 2.29, a similar scaling Emax ∼kBTecan be expected. The isothermal model has been extensively compared to results from Particle-In-Cell simulations, in good agreement for intensities up to 1020 W/cm2[18,17]. This scaling has been also experimentally evaluated in terms of the pulse duration in [36], showing good agreement below 200 fs. 2.3.2 Proton beam properties Typically, the obtained ion energy spectra at laser-driven acceleration experiments show a Maxwellian-like decay distribution with a sharp cut-off in energy[29]. As explained in the previous section, this is a result of the broad distribution of the sheath electrons. The ions are emitted with a certain cone-shaped angular distribution, with a narrower dispersion for the particles of highest energy than for the less energetic ones. This angular divergence can be considered as a Gaussian angular profile[37,38] g(θ) = 1 √2πσe−1 2(θ σ)2 (2.30) with a dispersion σthat depends on the proton energy with a linear or parabolic profile, as σ(E) = m·E+n(2.31) σ(E) = q|a·E+b|(2.32) Due to the origin of laser-driven ions being at the contaminant layer at the surface of the acceleration targets, multiple ionic species typically compose the resulting beams. Ions with higher charge-to-mass ratio are in principle accelerated more efficiently. So is the case of protons which, as they are the lightest species, usually tend to dominate the acceleration process. However, the use of certain specifically processed targets may allow for the enhancement of a different ionic species. For example, the use of deuterated targets has been explored in [39] to produce deuteron beams. In other cases, special treatment of the target surface in order to remove the hydrocarbon impurities has lead to the direct acceleration of heavier ions [40]. This could also be achieved by modifying the laser properties [41].
24 Chapter 2. Background and state-of-art Other properties of laser-accelerated ions, regarding the typical magnitudes in the context of particle acceleration, are a high particle flux (109– 1013 particles per pulse), a short pulse duration (∼ps), and a micron source size. A very low emittance, defined as the the dispersion of the particles in the phase space, is also a fundamental property of laser-driven ions. For tabletop or high-repetition rate laser systems, these ion bunches are produced at the operation rate of the laser, in the order of a few Hz. 2.4 Radiation-matter interaction 2.4.1 Interaction of charged particles with matter When a charged particle propagates through matter, it can experience several mechanisms such as elastic collisions with atomic electrons, inelastic scattering, or radiation emission within the electric field of the nucleus, also called bremsstrahlung. The transmutation of the atoms of the medium through nuclear reactions can also occur, although they are not considered in this section. On average, these processes will lead to the gradual loss of energy of the particle within its propagation. The rate at which the particle losses its energy can be characterised by the linear stopping power, defined as Sp=−1 ρ dE dx =−1 ρ"(dE dx )col + (dE dx )rad#(2.33) where dE is the amount of energy lost along a distance dx inside a material of density ρ. It can be divided in the energy loss due to mechanical processes, i.e., collisions, and radiation processes. Charged particles traversing a medium can be separated into two categories depending on their mass. In the range of application of this thesis: light leptons such as electrons and positrons, and heavier hadrons like protons or ions. The description of the energy loss is slightly different for each group of particles, as some processes dominate the interaction depending on the type of particle, its energy, and its mass. In the case of heavy charged particles, collisional processes are dominant in the ∼MeV range. Therefore, the sopping power in Eq. 2.33 can be approximated to the collisional component, whose description is given by the Bethe-Bloch formulation[42]. The expected maximum range of an hadron inside matter can be calculated from its stopping power as
2.4. Radiation-matter interaction 25 Rmax(E)≈ZE Emin (dE/dx)−1dE (2.34) where Emin is the minimum energy at witch the Bethe-Bloch formulation is valid (v < 0.25c). From the evaluation of Bethe-Bloch formula, a particular phenomenon for hadrons travelling through matter is derived: they deposit most of its energy at the end of its range and within a very short distance. This energy deposition distribution is commonly referred as the Bragg peak of the hadron beam. Some detection configurations, as will be mentioned in Ch. 3, take advantage of this circumstance. The emergence of other applications such hadron therapywere also motivated by this phenomenon. In the case of leptons, in contrast, as their mass is about a factor of 1000 lighter than the mass of protons, the relativistic regime is reached for lower energies. Thus, for the ∼MeV energy range, radiation losses (bremsstrahlung) are much more predominant than for hadrons. In addition, positrons can be disintegrated by means of electron-positron annihilation when their energy is low enough, in the order of ∼100 keV. This is the fundamental base of PET imaging. Due to their lighter mass, collisional processes on electrons or positrons produce larger scattering angles than for heavier hadrons. It can be then defined the mean free path as λe= 1/σcolN, in terms of the collisional cross-section σcol and the particle density of the medium N=ρNA/A, being ρits density, NAthe Avogadro constant, and Athe atomic mass. This parameter represents mean distance that a lepton can travel through a material without experiencing a collision. 2.4.2 Interaction of photons with matter There are three main mechanisms that govern the interaction of a single photon with matter: photoelectric effect, Compton scattering, and pair production. In this section, a brief description of the three processes will be provided. Through the photoelectric effect, the photon is totally absorbed by an atomic electron of the medium, which will be striped from the nucleus with energy equal to the difference between the photon energy and the binding energy of the atomic level. After the absorption of the photon, the vacancy left by the electron at the atomic level will be occupied by another electron at a later time, producing a characteristic X-ray or an Auger electron in the process.
26 Chapter 2. Background and state-of-art Compton scattering consists on the inelastic scattering between the photon and an atomic electron. In this mechanism, the photon transfers only a part of its energy to the electron and it is scattered at a certain angle. A correlation between the scattering angle θand the absorbed energy can be expressed as ∆λ=λf−λ0=λC(1 −cos θ)(2.35) where λfand λ0are the final and initial wavelengths of the photon, related to its energy through E=hc/λ, and λC=h/mecis the Compton wavelength. In pair production, a photon under the atomic electrostatic field can suddenly be totally absorbed to produce an electron-positron pair. In contrast to the other two mechanisms, pair production exhibit a energy threshold below which it cannot occur. This threshold correspond to the sum of the electron and positron rest masses, which is 1.022 MeV. The probability of these mechanisms mainly depends on the photon energy and the atomic number of the propagation medium. For low-energy photons the predominant mechanism is the photoelectric effect. It is also favoured for materials with high atomic number. In the keV range of energies, this mechanism effectively compete with the Compton scattering, which predominates up to the MeV energy scale. For relativistic energies above 1 MeV, the probability of pair production increases dramatically and becomes dominant. The overall effect of the three mechanisms described here can be averaged by means of the linear attenuation coefficient µγ. In this way, a photon beam traversing a material will experience a certain attenuation depending on its energy, following expression I(z, Eγ) = I0exp(−µγ(Eγ)·z)(2.36) where I0is the initial intensity of the ion beam before entering the material, I(z)is the intensity at depth z, and µγis the attenuation coefficient at the energy Eγ. In contrast to the case for charged particles, the propagation of a photon beam within matter leads to its gradual attenuation but maintaining a constant energy, on average.
2.5. Radioisotope production 27 TABLE 2.1: Nuclear reactions of interest for the production of radioisotopes used in PET. Dash lines indicate a energy threshold below 1 MeV. Nuclear reaction (-) Energy threshold (MeV) Product half-life (min) 11B(p,n)11C 1.13 20.23 10B(d,n)11C - 20.23 14N(p,α)11C 4.5 20.23 16O(p,α)13N 6.6 9.97 15N(p,n)15O 3.8 1.87 14N(d,n)15O - 1.87 18O(p,n)18F 2.5 109.77 2.5 Radioisotope production Through previous sections, the diverse mechanisms that result in the efficient acceleration of ions were described. As introduced in Ch. 1, one of the potential applications for laseraccelerated ions is the production of radioisotopes. As the spectrum of laser-driven ions spans over several MeV and is characterised by a high flux, it is suitable for the induction of nuclear reactions on a secondary target. The fact that protons are the predominant species in laser-driven sources is another advantage, as most of the production reactions are induced by light particles such as protons or deuterons[43,44]. In some experiments, these nuclear reactions are used as a diagnostic of the proton acceleration process[45,46]. Experimentally, laser-accelerated protons can induce nuclear reactions by locating a secondary target within the path of the proton beam[47,48,49]. Through the proper election of the target material and an adequate study regarding the available reaction channels, the radioisotope of interest can be produced. In the context of PET medical imaging, there are several nuclear reactions induced by MeV-order protons or deuterons that produce the desired isotopes. Table 2.1 lists some of these reactions[43,44,50], along with the threshold energy of the reaction, if any. Regarding the work presented here, the reaction 11B(p,n)11C is the main channel for the production of 11C from the proton beams generated within the experiments performed on laser-driven acceleration. This will be addressed in the corresponding chapter, Ch. 6. The probability that a nuclear reaction occurs at a certain energy of the incidental particle
28 Chapter 2. Background and state-of-art Proton-induced reactions Cross-section (mb) 0 100 200 300 400 500 600 Proton energy (MeV) 0 2 4 6 8 10 11B(p,n)11C 14N(p,α)11C 18O(p,n)18F Deuteron-induced reactions Cross-section (mb) 0 100 200 300 400 Deuteron energy (MeV) 0 1 2 3 4 5 6 7 10B(d,n)11C 14N(d,n)15O FIGURE 2.3: Cross-sections of some production reactions of radioisotopes of interest in PET. is determined by the cross-section, also known as excitation function. Fig. 2.3 depicts the cross-section of some of the nuclear reactions included in Table 2.1, induced by protons (left) or deuterons (right). As can be seen, the main peak of the curves is below 10 MeV, which is the typical range of energies achieved in most of the ultraintense laser facilities. The activity of a radioactive source is defined as the amount of disintegrations per time unit. This decay rate is often characterised by the disintegration constant λcor the half-life T1/2of the radioactive nucleus, which are related via λc= ln(2)/T1/2. The later is defined as the the period of time in which half of the radioactive activity has decayed. Thus, the activity at a given time tcan be expressed as A(t) = A0exp(−λct)(2.37) where A0is the initial activity. From this expression, the number of nuclei of the radioactive source Ncan be simply derived as N(t) = A(t)/λc=N0exp(−λct)(2.38) being N0again the initial number of nuclei. Eq. 2.38 is commonly known as the law of radioactive decay.
3.1. Ultraintense lasers 35 to 1018 – 1022 W/cm2. Ultraintense lasers can be separated into two main types. High power petawatt lasers based on Nd:YAG or Nd:glass crystals exhibit pulse durations of the order of several hundreds of femtoseconds, up to a picosecond, and pulse energies reaching more than 50 J. On the other hand, table-top high repetition rate laser systems, composed of Ti:Sa crystals as the gain medium, produce shorter pulses, of few tens of femptoseconds, and pulse energies below 10 J. Regarding multi-shot operation, the later can achieve pulse rates typically in a Hzorder or above, even reaching frequencies up to the kHz scale for certain configurations, while high power lasers are mostly limited to a single shot each few minutes. Relevant parameters of ultraintense lasers log(t) log(I) ASE Pedestal Main pulse 0-10-9 FIGURE 3.2: Schematic representation a ultraintense ultra-short laser pulse. Despite their output and operation differences, most laser systems exhibit pulses characterised with the same parameters and a similar temporal distribution. Fig. 3.2 depicts a schematic representation of an ultrintense ultra-short laser pulse. Several components at various relative intensities from different origins can be observed. The main pulse, which carries the peak intensity of the laser pulse, has a typical duration in the order of femtoseconds for table-top lasers, or up to a picosecond for high power low repetition rate laser systems. In a nanosecond scale preceding the main pulse, the distribution show a contribution with a relative intensity of 10−6 – 10−10 orders of magnitude below the peak value. This long pedestal is produced due to the Amplified Spontaneous Emission (ASE), coming from the pumping and amplification phases.
36 Chapter 3. Methods Other component within 1 – 10 picoseconds is produced by uncompensated dispersion as a result of imperfections and misalignment of the components in the compressor gratings or some other optical elements during the pulse processing. Its relative intensity is of the order of 10−3 with respect to the main pulse. Due to some unavoidable leakages of the laser pulses during the pumping phase, additional prepulses are expected to appear before the main pulse. Although the relative intensity of the prepulses varies from laser to laser, they are typically above the ionisation threshold, at about 1015 W/cm2. Both the pedestal and these prepulses are responsible of preplasma formation when an ultraintense pulse impinges on a solid target, which allow for the efficient acceleration of electrons and ultimately ions upon the arrival of the main pulse, according to the mechanisms described in Ch. 2. An important parameter of ultraintense laser pulses in the context of particle acceleration is the formally called contrast ratio, which is defined as the relative intensity between the main pulse and the nanosecond and picosecond pedestals. Two contrast ratios are thus usually given concerning the nominal temporal characterisation of a laser system. One of them at the nanosecond scale, accounting for the ASE contribution, and the other one at ∼10 ps, related to the uncompensated dispersion. There are several techniques for the suppression of these components and the enhancement of the contrast ratio, for example XPW (cross-polarised wave) modules[66] or Pockels cells[67], being one of the most extended the use of a plasma mirror[68] within the laser transport. Some applications require proper prepulse cleaning and ultra-high contrast conditions. In particular, for the irradiation of thin targets below 1 µm-thick, it has been demonstrated that a non-optimised laser contrast can lead to the destruction of the target before the arrival of the main pulse, hence reducing the efficiency of the subsequent particle acceleration[69,70]. The spatial distribution of ultraintense laser pulses can be considered as Gaussian in good approximation. Depending on the laser system and its optical elements, the laser pulse diameter ranges between 2 and 10 cm. Ti:Sa lasers tend to be shorter than Nd:YAG systems as generally the size of the crystals are smaller, due to the technical difficulty to grow large pieces. In most of the experimental cases, pulses are focussed via reflecting systems, typically a Off-Axis Parabola (OAP), down to micron spot-sizes thus reaching peak intensities of up to 1020 – 1022 W/cm2. Refractive focussing systems are avoided due to their propensity to being damaged at the achieved pulse intensities. Due to the spatial profile of the laser beam and the focalisation process, a 84% of the pulse intensity is concentrated in a central Airy disc of diameter dAand FWHM (Full Width at Half Maximum) dF WHM given by
3.1. Ultraintense lasers 37 dA= 2.44λLf(3.1) dFHW M = 2.05λLf(3.2) being λLthe laser wavelength and fthe f-number of the OAP, defined as the quotient of the focal length divided by the entering beam diameter. A focussing Gaussian beam along a z-direction follows a size profile as determined by expression w(z) = w0s1+(z zR )2(3.3) In this equation, w(z)denotes the beam radius within its focussing profile and w0, called the beam waist, corresponds to its radius at the narrowest point. In the experimental situation, this parameter is often referred as the focal spot. The parameter zRis known as the Rayleigh length of the optical system, and is defined as the distance from the focal spot at which the radius of the focussing beam is reduced by a factor of √2. From Eq. 3.3, it can be calculated as zR=πw2 0 λL (3.4) in terms of the minimal spot size of the focussing system, measured either experimentally or estimated via Eq. 3.1. The Rayleigh length is of special interest from an experimental perspective as it defines the required accuracy in the positioning of the surface of the acceleration target with respect to the laser focus. Beyond this value, the peak intensity rapidly decay and therefore, the energy transferred to the electrons or ions is dramatically reduced. This issue will be further explored in Ch. 4, regarding the development of the target assembly and the procedure for its precise positioning at the laser focus at high repetition rates. Lastly, the peak intensity of the focalised laser pulses is typically depicted by using the dimensionless amplitude a0, from its definition in Eq. 2.7. This magnitude is typically used as a comparison parameter between laser systems with different experimental conditions and specifications in most published reviews[6,29], as for example the pulse duration, the focal spot size, or the pulse energy.
38 Chapter 3. Methods 3.1.1 The STELA system Booster amplifier Oscilator JADE II Stretcher SAGA I SAGA II SAGA III Preamplifier Main amplifier Compressor Stretcher CPA regen. amp. Compressor XPW 1 mJ, 35 fs, 1 kHz 200 µJ, 1 kHz 1.4 J, 35 fs, 10 Hz FIGURE 3.3: STELA scheme. The Laser Laboratory for Acceleration and Applications (L2A2), at the Universidade de Santiago de Compostela[71], is equipped with a compact high repetition rate femtosecond ALPHA 10/XS Ti:Sa laser system (THALES) of 45 TW called STELA (Santiago Terawatt Laser). This laser system has two laser outputs (Fig. 3.3): the low energy beam line can deliver s-polarised laser pulses of 1 mJ and 30 – 50 fs at a repetition rate of 1 kHz with a ns-contrast ratio of 10−6. This line is used in X-ray generation and dedicated to novel imaging techniques[72]. The high energy beam line is mainly intended for ion acceleration. It can deliver p-polarised laser pulses of 1.4 J and 25 – 50 fs at a repetition rate of 10 Hz and an improved contrast ratio down to 10−10, achieved with the XPW technology. Fig. 3.3 depicts a scheme of the front-end structure of STELA. The s-polarised seed from the oscillator is stretched, amplified, and compressed in an initial phase via the CPA technique.
3.1. Ultraintense lasers 39 A JADE unit containing a Nd:YAG laser is utilised for the population pump of the crystal at the regenerative amplifier, as these lasers have a wavelength of 1060 nm, twice the distance between the atomic levels for the population inversion of a Ti:Sa crystal. The resulting outcome of this phase correspond to the low energy line of the laser. For the line at high energy, the beam is attenuated by removing a component of its polarisation, and then directed to the XPW module, in order to clean the laser pulses from their pedestals and prepulses. After this phase, the nominal pulse energy has reduced to a few µJ. In order to increase this energy up to the ∼J level, another amplification cycle is performed. As the Ti:Sa crystals would not tolerate such energy density at 1 kHz, the repetition rate is decreased down to the pumping operation rate, 10 Hz, through a pockels cell. Several SAGA units are employed for the pumping at the amplifiers by means of Nd:YAG lasers. Intensity (I/Imax) 10-10 10-8 10-6 10-4 10-2 100 Time (ps) -60 -50 -40 -30 -20 -10 0 STELA Ionisation level FIGURE 3.4: Contrast of the laser pulses at L2A2. The temporal distribution of the laser pulses of the high energy beam line, measured with aSPIDER diagnosis system after the compressor, is shown in Fig. 3.4. As can be seen in the figure, the main pulse present an ultra-high contrast ratio (about 10−9and it is clean of prepulses at the nanosecond scale. A short prepulse close to the main pulse of the at around 0.5 – 1 ps of the order of 1016 W/cm2can be observed.
40 Chapter 3. Methods 3.1.2 The VEGA 3 system FIGURE 3.5: Schematic representation a ultraintense ultra-short laser pulse (image from https://www.clpu.es/). The VEGA laser system, held at the Centro de Láseres Pulsados (CLPU) in Salamanca, Spain, counts with three main laser lines at increasing maximum powers: VEGA 1 (20 TW), VEGA 2 (200 TW)[73], and VEGA 3 (1 PW). Fig. 3.5 shows a layout of the overall laser structure. From the front-end, that contains a Ti:Sa oscillator, a double CPA system for the pulse amplification, and a XPW unit for contrast reduction, the laser beam is split to the first output line (VEGA 1). Throughout this line, laser pulses are again amplified by means of multipass amplifier and compressed down to 30 fs at 600 mJ-pulse energy and a repetition rate of 10 Hz. For the second laser arm (VEGA 2) several phases of amplification by multi-pass amplifiers before compression lead to laser pulses of up to 6 J. For the third and last laser output, at which the experiments of this thesis were carried out, a component of VEGA 2 laser line is amplified to higher energies and compressed. After that, the beam wavefront is properly corrected by
3.2. Diagnoses for laser-driven ion acceleration 41 means of a deformable mirror. Laser pulses up to 25 J and 30 fs at a repetition rate of 1 Hz thus arrive at the interaction chamber, for ion acceleration experiments. Intensity (I/Imax) 10-12 10-10 10-8 10-6 10-4 10-2 100 Time (ps) -80 -60 -40 -20 0 VEGA 3 Ionisation level FIGURE 3.6: Contrast of the laser pulses at CLPU. Due to the use of a XPW module at the laser front-end, the achieved contrast ratio after compressor of VEGA is about 10−12 at the nanosecond scale, and of the order of 10−8– 10−5 for the picosecond pedesta. This is illustrated in Fig. 3.6, that depicts a temporal trace measured at the CLPU for the VEGA system. Some intense prepulses up to 10−5can be observed as well in the ∼10 ps-range. As the intensity of these prepulses is above the ionisation level, they are responsible for the formation of preplasma at the front side of the acceleration targets, and in principle discard the possibility of using thin targets. 3.2 Diagnoses for laser-driven ion acceleration Due to the ultra-short regimes for the laser-plasma interaction and the particle acceleration mechanism depicted in Ch. 2, in the sub-picosecond range, particle-to-particle measurements are not experimentally feasible. Instead, detection systems that integrate the whole pulse are required[74,75]. In addition, these diagnostic technologies must be capable of functioning at high-rate multi-shot conditions for at last several minutes of operation. Until the development
42 Chapter 3. Methods and standardisation of high-repetition rate laser systems, the properties of laser-accelerated ions were diagnosed by means of single-use, passive detectors, that required a certain postprocessing after the irradiation to extract relevant data. Some of these detectors are CR-39[76], Radio-Chromic Films (RCF)[77], or image plates (IP)[78]. Although they are very popular and are still widely used for some ion beam diagnostics such as beam divergence or particle flux, the interest and the development of detection systems for pure multi-shot operation that offer real-time information on a shot-to-shot basis have been recently increased. Aside from the high-repetition rate and the short ion bunch duration, special concerns arise from the high particle fluxes that are generated through laser-driven acceleration. Saturation of the detectors is an actual issue in most of the experiments on this topic, which is solved by using optical or particle filters. Together with bursts of charged particles and energetic photons, huge electromagnetic pulses (EMP) emerge from the laser-plasma interaction at high power laser facilities. These EMPs, that have been also studied in literature[75], can affect the electronics of nearby devices to the interaction point. Electron beams and X-rays are also produced according to the mechanisms described in Ch. 2. The former are typically removed via magnet systems, or used as secondary diagnosis of the laser-plasma interaction. For the later, detection devices that are not sensible to electromagnetic radiation are favoured. Traslucent or opaque filters to visible light are also commonly located enclosing the detectors to reduce undesired noise at the retrieved signals. This section compiles an overview of some of the most extended diagnostic systems used in laser-driven ion acceleration, with special emphasise on those that were used in the experiments performed within this thesis. 3.2.1 Micro-channel plates Micro-channel plates (MCP)[75,79] are detectors for high-vacuum environments that consist of a matrix of thin micron-size tubes, or channels, arranged under an electric field and acting as electron multipliers. Incidental particles on the MCP will generate secondary electrons at the active medium that, impelled by the electric field, pass throughout these channels. The electrons are then multiplied in subsequent collisions with the channel walls, hence amplifying the initial charge by several orders of magnitude. Typically, MCPs are attached to a phosphor screen that converts these electronic cascades to visible light via phosphorescence, whcih can be retrieved by a CCD camera. Fig. 3.7 pictures a schematic section of a MCP. The spatial resolution of
3.2. Diagnoses for laser-driven ion acceleration 43 a MCP is roughly given by the diameter of the channels, around 4 – 25 µm. Multiple MCPs can be stacked in order to enhance the amplification of the signals, yet at the expense of reducing the measuring resolution. The working principle of MCPs is based on secondary electrons from primary interactions, therefore they are sensitive to all types of ionising radiation, i.e., ions, electrons, X-rays, and neutrons. This may suppose a complication for the detection of laser-accelerated ions due to the significant electron and photon fluxes that are produced in the laser-plasma interaction. eγ E Phosphor screen Photocathode FIGURE 3.7: Schematic representation of the section of a micro-channel plate (MCP). As multiple parameters characterise both the signal amplification, such as the plate thickness, the relative angle of the channel axis, the electric field strength, or the particle incidence angle; and the visible light detection, like the CCD gain, the exposure time, or the distance to the camera, the calibration of MCP detectors must be performed for a fixed configuration MCPCCD. For Thomson Parabola spectrometers, that involve multiple incidence angles, as described in Sect. 3.2.4, this issue is of special relevance. A common calibration procedure involves the use of a Thomson Parabola and a stripped CR-39 placed in front of the MCP to cross-correlate the light ratio at the CCD with the single particle counting of the CR-39[79]. 3.2.2 Scintillators Inorganic scintillators[80] are a type of plastic material that converts energy deposition from external ionising radiation to visible light. This light can be then collected via a photomultiplier (PMT) that amplifies the signal to a detectable level. When a particle traverses a scintillator material, it creates a trail a excitations on the medium molecules along its path. These excited
44 Chapter 3. Methods states rapidly decay through fluorescence de-excitations and a certain, proportional fraction of the energy deposited by the particle is emitted as visible photons at a central, characteristic wavelength given by the transition energy. A key feature of scintillator materials is that they are transparent to their own light. The typical configuration consists of a plastic scintillator attached to a fast PMT readout. Light entering the PMT photocatode produces electron excitations that are accelerated by the electric field on a series of dynodes. Secondary electrons are induced as well, leading to an electron avalanche whose charge is proportional to the input energy. The signal from the PMT is retrieved by an acquisition system, usually a fast oscilloscope. As the light is produced and collected in a picosecond to nanosecond temporal scale, plastic scintillators exhibit a fast response and constitute a suitable choice for online measurements at high repetition rates. In addition to their output stability, they are available in most sizes and shapes as they are usually cut from larger pieces to the desired dimensions. Stacks of scintillator sheets at different central wavelengths have been used as a beam profiler to characterise the spatial transversal distribution of ion beams at various energy ranges[74,81]. However, a noticeable drawback of PMT readouts is that they tend to saturate for high input particle fluxes. This is a common circumstance for laser-driven particle acceleration, at which an intense bunch of photons, electrons, and ions arrive at the detector within several nanoseconds. This issue is typically addressed by using sets of optical density (OD) filters between the scintillator and the PMT. 3.2.3 Time-of-flight Time-of-flight (ToF) detection systems provide time-resolved measurements of particle beams according to their kinetic energy. They are based on the principle that particles travelling at different velocities reach the detector at different times given by their energy. Through this approach, a detection device, typically composed of a scintillator and a PMT readout attached to a fast oscilloscope, is placed at a fixed distance from the acceleration source. The bunch of accelerated particles, upon reaching the detector, generates a bump signal extended over a short time. By knowing the travel distance and the expected mass of the detected particles, each temporal bin of the retrieved signal can be related to a energy. Hence, the signal can be analysed to obtain an spectral distribution for the particle beam. In the case of laser-accelerated ions, this corresponds to a broad maxwellian-like spectrum, as explained in Ch. 2.
3.4. Particle-In-Cell simulations 51 Coincidence configuration Coincidence measurements are a special type of event detection that involves two or more detectors. It is used for radioactive sources that emit several correlated photons in a short temporal window, as for example the cascade emission from the decay of certain nuclei, or the backscattered photons from the annihilation of positrons, associated to β+radioisotopes. A typical experimental configuration for activity characterisation consists of two detectors located along the same axis facing each other, being the radioactive source placed in between them. To select events corresponding to the emission of two γ-photons in temporal coincidence, counts are only registered and histogrammed if an interaction occurs at both detectors within a time window specified by the acquisition. As an initial approximation, the total efficiency of the detection assembly can be set as the multiplication of the individual efficiencies of both detectors. In this case, Eq. 3.12 can de adjusted to Rc ph =A·Iγ·BR ·(εph t,1·εph t,2)(3.16) where Rc ph is defined as the number of photopeak counts per unit time in coincidence configuration, and the εph t,j factors correspond to the total photopeak efficiency of detector j. Some advantages of coincidence measurement are the significant background suppression and the reduction of secondary interactions. In this way, all the registered photopeak counts can be assumed to be single and distinct disintegration events from the radioactive source. 3.4 Particle-In-Cell simulations Numerical simulations have become a powerful and effective computational tool for the comprehension of the underlying physics of complex experimental situations. In the context of plasma physics, and in particular laser-plasma interactions, Particle-In-Cell (PIC) simulation codes are widely extended[87,88]. The large number of parameters and acceleration mechanisms involved in the interaction, as explained in Ch. 2, make PIC simulations an effective means of understanding the experimental case and complement the empirical data[89,90]. While some modern PIC algorithms contemplate collisions and other processes as dynamic ionisation[91,92], the core Particle-In-Cell method in plasma physics assumes a collisionless plasma which can be described by the Vlasov-Maxwell equation
52 Chapter 3. Methods ∂fs ∂t +v·∇fs+FL·∂fs ∂p= 0 (3.17) where fs(t,x,p) denotes the distribution function of a particle species swith position x, velocity v, and momentum p. As in Eq. 3.8,FLcorresponds to the Lorentz force. The approach of PIC algorithms for solving this equation consist of the discretisation of the particle distribution into "macro-particles", which are arranged into the elements —or cells— of a static spatial grid. Each of these macro-particles represent a group of weighted particles characterised by their mass and their charge. Then, the evolution of these particles is separated into two solvers: the movement of the particles under the presence of electromagnetic fields, and the calculation of the updated electromagnetic fields produced by these charged particles, along with external ones. EM fields at particle positions Advance particles (equations of motion) Charge and current densities on the grid EM fields on the grid Δt (E,B) →FL FL →(x,v) (x,v) →(ρ,J) (ρ,J) → (E,B) FIGURE 3.10: Typical temporal scheme for Particle-In-Cell simulations. For each temporal cycle of the simulation, four computational steps are performed, as schemed in Fig. 3.10: given that the electromagnetic fields are initially defined at the grid points, they are firstly interpolated at the particle positions. Secondly, the particles are advanced according to the Lorentz force (Eq. 3.8) an their equations of motion. In this way, for each macro-particle, the new position and momentum are calculated via the Boris pusher[93]. For the third step, the charge and the current densities are calculated on the elements of the simulation grid from, respectively,
3.4. Particle-In-Cell simulations 53 ρ(x) = N X j=1 qjS(xj−x)(3.18) J(x) = N X j=1 qjvjS(xj−x)(3.19) In these expressions, Nis the number of macro-particles, whose shape is described by a function S(xj−x). The evolution of the electromagnetic fields is finally computed from the charge and current densities, along with the presence of external contributions —for example, a laser pulse—, by solving the Maxwell’s equations ∂B ∂t =−∇×E(3.20) ∂E ∂t =c2∇×B−J 0 (3.21) A relevant constraint for PIC simulations is the CFL (Courant-Friedrichs-Lewy) condition[94], that imposes a relation between the spatial and temporal resolutions to guarantee the stability of the numerical algorithm. In this way, the chosen time-step must satisfy c∆t ∆x≤1(3.22) ∆t( n X i ci ∆xi )≤1(3.23) for the one-dimensional and n-dimensional cases. The parameter ciis defined as the velocity magnitude at each dimension. 3.4.1 The Smilei code Regarding the PIC simulations performed within this thesis, the Smilei code[92] was utilised. Smilei is an open source collaborative code for plasma simulation with a multi-purpose perspective for its application in many related fields. Thus, it include a list of several modules that
54 Chapter 3. Methods account for other interaction processes as field-ionisation, binary collisions, or QED (Quantum Electro-Dynamic) processes. As intended for high-performance execution in super-computer clusters, it is based on a hybrid MPI-OpenMP (Message Passing Interface) parallelisation protocol. The simulation space is split into groups of cells called patches, which are associated to MPI regions that share the same memory and are executed as the same task. As a novel approach with respect to other PIC codes, Smilei redistributes the patch-MPI region assignation during simulation to reduce the load weight of those regions with higher computation requirements, by giving patches to adjacent regions with less load. This procedure, so-called dynamic load-balancing, leads to a better computing optimisation. Smilei has an additional module, called happi, for the processing, analysis, and representation of the simulated data. Within this thesis, this code was used for simulations on laser-driven ion acceleration by ultraintense laser pulses. The experimental situation at each of the campaigns of this work was replicated in order to complement the measured data, and to obtain relevant scalings with some the interaction parameters to obtain precise estimations on radioisotope production. In the context of this thesis is worth noting the Smilei module that accounts for dynamic fieldionisation, which is not contemplated in the standard PIC formulation. A detailed description of the ionisation model can be found in [92]. The use of this module allows for the ionisation of a ion species by the influence of external electromagnetic fields or those produced by other particles. The implementation of this module in the simulations described in this work, as well as the impact of dynamic field-ionisation on the results, will be further explored in Sect. 5.3 in Ch. 5.
55 Chapter 4 The multi-shot target system 4.1 Motivation and state-of-art While laser-plasma acceleration is characterised by a huge peak power, as explained in Ch. 2, many of the foreseen applications of this technology require a minimum average power. This average power is related to the continuous operation of the laser accelerators, that is based on the energy and pointing stability of the laser system, and the shot-to-shot replacement and positioning of the target material. Moreover, the repetition rate of the laser pulses[95] together with the design and operation mode of the target assembly[96] are both crucial to achieve a high average-power regime. Concerning target engineering, several multi-shot technologies have been proposed. Tapedrive-based targets allow for tens of thousands of shots, that at 10 Hz would correspond to almost one hour of continuous operation[97]. The main drawback of these systems is the limited variety of tape materials and thicknesses suitable to withstand the mechanical stress caused by the continuous movement. An alternative is a multi-target holder system that is capable of moving along three or more degrees of freedom, allowing for rectangular[82] or cylindrical geometries[98]. The total number of possible shots for this option is in general smaller, around a few thousand, corresponding to few minutes of continuous operation. However, the variety of suitable target material and thicknesses is higher as the foils are externally supported by a rigid structure. In particular, the idea of using MEMS technology to fabricate micro-nano targets on silicon wafers represents a very attractive option[99,100,101]. This technology allows for manufacturing large volumes of micro-targets made of different materials and thicknesses,
56 Chapter 4. The multi-shot target system including composites of various distinct layers. Moreover, more recent and promising developments related to the use of liquid targets[102], or cryogenic solid hydrogen targets[103] will open the possibility for long operation periods. However, one of the challenges to be solved is the micrometric positioning of the liquid jet or the solid-hydrogen ribbon. The accurate positioning of the target material at the laser focus is indeed a common challenge for all multi-shot target technologies. The typical thicknesses of the target material, and the values of the Rayleigh length for short focal lengths, require shot-to-shot position accuracy of the order of a few microns. Therefore, the target assembly should guarantee not only the replenishing of the target material, but also its accurate position at the laser focal point at a speed compatible with the laser pulse rate. These requirements are not only valid for laserplasma acceleration, but also for other applications of laser-matter interaction as the generation of coherent XUV in forthcoming facilities[104]. In this chapter, the multi-shot target assembly, designed and commissioned at the Laser Laboratory for Acceleration and Applications (L2A2), will be presented (Sect. 4.2). In Sect. 4.3, the implemented procedure to guarantee the shot-to-shot replenishing of the target material and its accurate positioning at the laser focus at high repetition rates will be described. The operation of the target system, concerning its automation and synchronisation with the laser pulses during the irradiation experiments will be explained in Sect. 4.4. As the development of the target system presented in this work is comprised within the L2A2 commissioning campaign, it was originally designed according to the characteristics and constraints of this facility. However, as it will be seen through the following sections and in the experimental chapters (Chs. 5 and 6), this system can be easily adapted to other laser systems. Final conclusions will be given in 4.5. 4.2 Target assembly design The target assembly designed at the L2A2 is based on a multi-target wheel mounted on a set of three moving stages, to guarantee the shot-to-shot replacement and positioning of the target material. Several models of wheel-like holders were considered and tested during this work (Fig. 4.1). Since the beginning of this thesis within the commissioning of the L2A2 ion source, the target wheel has evolved from a purely single-shot design, used at the initial proof-of-concept experiments, to more advanced versions, aiming to exploit the performance
4.2. Target assembly design 57 FIGURE 4.1: Evolution of the target wheel design within this work. of the laser system and optimise the operation time. Although a sustained operation over time is a relevant factor to achieve, so it is the stability and repeatability of the target system, which ultimately determine the stability of the ion source. Thus, the manufacturing material and quality has been improved in the same direction, from 3D-printer plastic to aluminium and steel versions, offering the required grade of robustness and flatness. The first version of the multi-target wheel that allow for multi-shot operation, shown in the left (a) panel in Fig. 4.2, consists of a drilled aluminium disk with eight apertures for the allocation of the target foils. These apertures are divided into two different arrangements, four of them consisting of five discrete circular holes for single-shot measurements, and another four long slots intended for multi-shot operation. On top of each orifice, a bored plate is screwed to the wheel to fit the target sheets. Both the holes and the slots are bevelled with an aperture of 70◦in order to allow for incidence angles up to 45◦from the normal direction. Taking 1000 µm as a conservative reference value for the distance between impact positions, the maximum number of possible shots in multi-shot operation is 4 series of 25. This amount can be doubled if two parallel rows of impact positions are used for each slot. The second version of the multi-shot target wheel, designed for multi-shot operation, is shown in the right (b) panel in Fig. 4.2. It is composed of a larger iron disk (200 mm-diameter)
58 Chapter 4. The multi-shot target system FIGURE 4.2: Target wheels. and eight frontal circular sector plates, mechanically pressing and tightening the target foils. Six of the sectors have five curved target slots of 4 mm-wide and a 70◦-bevelling, separated 8 mm, whose length depends on the slot radius. This configuration represents a clear increase in the number of possible shots in comparison to the first version. Given the same reference distance between impact positions (1000 µm) the typical number of possible impacts per slot can vary between 26 for the inner slots and 42 for the outer ones. According to these values, the total number of shots using the six target sectors would be 1020 (2040 for two-row series of shots per slot). The two other sectors have squared slots to host micro-target arrays produced using the MEMS technology[100]. An update of this wheel version replaces these two sectors by standard ones, for which the number of possible shots increases up to 1360 (2720 for two-row series of shots per slot). A slightly different approach was considered for the development of the third version of the multi-shot target wheel (Fig. 4.2, right panel). This target holder was designed for a experimental campaign at the Centro de Láseres Pulsados (CLPU), Salamanca, Spain (see Sect. 5.2), for a laser system with 20 - 30 times higher energy per pulse. Thus, in order to prevent the possible effects of each laser pulse on adjacent impact positions, a pattern of circular individual holes was chosen over long curved slots. As for the previous version, the wheel-like holder consists of a base stainless steel disk of 244 mm-diameter, and eight sector plates that fit the target foils. Each sector, both for the disk and the plate, is drilled with a matrix of 101 holes of 2.3 mmdiameter and a 70◦-bevelling, arranged along nine arcs at different radii. The center-to-center distance between holes, as well as the distance between radial arcs, was set to 5.5 mm, enough for the maximum operation rate of 1 Hz at CLPU. The total number of targets of this holder
4.2. Target assembly design 59 version is 808. FIGURE 4.3: Target assembly. Following the same conception, an upgraded version of this target wheel, capable of operating at 10 Hz, was designed and manufactured. In this case, each sector of the base disk was completely bored and two sector plates, drilled with the hole pattern and hosting the target foils in between, were screwed on top of each sector aperture. With respect to the previous version, the size of the base disk was increased to 304 mm-diameter and the center-to-center distance between holes was reduced to 2.5 mm, both in the radial and angular axes. In order to achieve the later, the bevelling of the holes was removed by reducing the width of the sector plates from 2 mm to 0.5 mm. The hole pattern consists of eighteen arcs at different radii containing between 29 and 43 holes each, for a total number of 650 per sector, and of 5200 for the whole wheel. The target wheel, whichever version, was mounted on one rotating and two linear moving stages (Fig. 4.3). The rotating stage and one of the linear stages, that move perpendicularly to the target normal, were used to refresh the target material between shots, whereas the second linear stage, that moves longitudinally to the target normal, was used to place each target position at the laser focus. The stages are vacuum compatible from PI miCos: LS-110 and PLS-85 for the linear ones and DT-65N for the rotating stage, with spatial resolutions of 20 nm, 10 nm, and 20 µdeg and maximum speeds of 22 mm/s, 12 mm/s, and 22 ◦/s, respectively. These values are more than enough to match the small tolerance for the positioning of each target at the laser focus, ∼10 µm (explained below).
60 Chapter 4. The multi-shot target system 4.3 Target characterisation The estimated Rayleigh length of the focussing beam in the experimental set-up at the L2A2, of ∼10 µm, defines the tolerance for the positioning of the targets. Due to the mechanical deformations in the multi-target wheel and the target foils surface, as well as the wobbling angle of the rotating stage, it is not possible to guarantee such accuracy in the target positioning and therefore, an automated correction system is required. The implemented solution consists of a correction procedure based on the complete characterisation of the target surface, via a detailed 3D-mapping of the impact positions of the laser pulses on target. To obtain this 3D map, the transversal coordinates of the desired impact positions on the target surface are defined prior to the irradiation. The longitudinal coordinate along the target normal, which is affected by the surface deformation, is measured with an OptoNCDT ILD1320 distance sensor by Micro- Epsilon. The 3D position map (see Fig. 4.4 for two examples) is then converted into a matrix of encoder positions for the moving stages, which is used by the LabVIEW-based control software of the target assembly to correct the surface deviation on a shot-to-shot basis during the laser operation. FIGURE 4.4: Deformation map for two of the target wheels. Color ramp in arbitrary units. As the target characterisation is performed before the laser irradiation, it allows for achieving high operation repetition rates during the ion acceleration experiments. The commonly extended procedure for the positioning of the surface of the targets at the laser focus involves
4.3. Target characterisation 67 FIGURE 4.7: Distance sensor performance tests for materials with various reflectivities. the typical total deformation of the target wheels is of the order of 500 to 1000 µm, which corresponds to a few 250 µm steps. The precision of the distance sensor within this distance is below 10 µm. In order to study the validity of the 3D-mapping technique, the surface profile of a 100 mmradius 1 mm-thickness uniform copper disk, mounted on the target assembly, was measured. In the image displayed in Fig. 4.8, the distance sensor and the dummy copper target, mounted on the three moving stages, are shown. The measurements were performed by moving the disk with the same speed as during target irradiations in order to include the effect of the wobbling angle of the rotating stage. The black solid and the red dashed lines in the left panel in Fig. 4.9 represent the deviation of the disk surface with respect to the normal plane measured for two radii of 74.2 mm and 64.2 mm, respectively. As can be observed, the surface deviates up to 500 µm at some positions. The gradual deviation of the surface profile for certain angles
68 Chapter 4. The multi-shot target system FIGURE 4.8: Image of the set-up used for the validation of the mapping procedure. FIGURE 4.9: Deviation of the copper disk surface before and after the correction. clearly indicates a deformation of the target, probably due to the way the disk is screwed to the rotating stage. In fact, the amplitude of the deformation decreases with the radius, as shown in the figure. The 3D map obtained with this method was then used as an input for the control software of the target assembly, in order to apply the corresponding longitudinal correction for each measured point at the target surface. To evaluate the performance of the position correction, a second measurement of the surface of the dummy target along the normal direction during the correction was performed. The results are reported in the right panel in Fig. 4.9 for the 74.2 mm radius. It can be seen that the correction procedure reduces the initial deviations in the dummy
4.3. Target characterisation 69 target surface along the longitudinal axis from around 500 µm to final deviations in the order of a few micrometers. However, the results still show a slight oscillation of about 3 µm, which can be attributed to the vibration of the copper dummy target due to the rotating movement. Nevertheless, this vibration is within the Rayleigh length of the L2A2 system and is expected to be smaller for the target wheels. 4.3.3 Validation The reliability of the correction and positioning system was also verified by means of a secondary diagnostic, independent from the distance sensor (ILD1320-10). A schematic representation of the experimental set-up can be seen in Fig. 4.10 (left panel). The beam from a visible diode laser was expanded with a two lens arrangement (f=−30 and f= 200) and then focussed on the surface of the targets by using a microscope objective (M Plan Apo NIR x50 by Mitutoyo). The backscattering light was then recollimated by the microscope and focussed on a CMOS camera (CMOS 5MP by Mightex) with a f= 75 lens. The position of the target surface with respect to the beam focus could be measured by comparing the relative size of the resulting spot shown in the image retrieved by the camera. A schematic representation of this principle is depicted in the right panel in Fig. 4.10. In this way, a correlation between the spot size of the beam at the target surface and the deviation from focus could be obtained for each point of the surface map, in order to validate the correction procedure. For the following, the positive direction considered for the deviation is given by the pointing direction of the incidental beam on target. As a first step, a 3D map of the target surface, using the long-slots version of the wheel-like holder, was measured with the distance sensor. As targets, 12 µm-thickness aluminium foils with two different surface qualities, shiny and matte, were used, in order to study the sensor performance at measuring materials with different reflectivity. The laser beam from the sensor was aligned, normal to the target surface, to a reference position on the target wheel given by the incidence point of the laser coming from the microscope objective (Fig. 4.10). After the surface characterisation, the correction from the map was applied to the whole set of target points, and the corrected positions were measured again with the distance sensor. This positioning verification was performed at a repetition rate of 10 Hz with the same movement profile as in the irradiation experiments at the L2A2, i.e., each 100 ms a new target point was placed at the path of the sensor laser and measured. The results, which can be seen in Fig. 4.11, present
70 Chapter 4. The multi-shot target system Diode Microscope Target Beam splitter Filter Camera f = -30 f = 200 f = 75 Camera Target Microscope FIGURE 4.10: Positioning validation set-up and principle. a systematic dispersion of ∼3.5 µm. The map curves had been normalised to the first map value, while the verification curves had been subtracted by its mean value. This procedure was repeated for several days under the same conditions, showing a great stability and coherence between measurements, as expected. After the mapping and the correction verification procedures, the distance sensor was removed from its location and the laser coming from the microscope objective was focussed to the same reference position over the target wheel. Then, the target surface corresponding to one of the measured map points was positioned at the focus of the laser beam (zero position). A focal scan was performed by moving the target along its normal direction from -150 to 150 µm
4.3. Target characterisation 71 FIGURE 4.11: Maps and verifications. with respect to the zero position at a step size of 5 µm. For each scan position, an image of the backscattered beam was stored. Thus, a calibration that correlates the relative position displacement with the spot size of the backscattered beam, i.e., the focussing beam profile, could be obtained. This procedure was performed for four map points, two of them for shiny targets and the other two for matte ones. In particular, the first map point of every two sector plates. Two methods were used for the calculation of the spot size of the backscattered beam from the retrieved images. For Method I, the X and Y sizes were directly determined from the intensity profiles (Fig. 4.12, green line), in number of pixels, from which the Root Mean Square (RMS) can be obtained as RMS[px] = sX2[px] + Y2[px] 2(4.9) which was used as a comparison parameter. For Method II, the beam spot size was characterised by the RMS (Eq. 4.9) of the FWHM (Full Width at Half Maximum) obtained by applying a Gaussian fit to the X and Y intensity profiles (Fig. 4.12, red line). The calibration curves for both methods are reported in Fig. 4.13. Panels (a) and (c) show the results for each one of the four measured points (two shiny and two matte) for Methods I and II, respectively, while in panels (b) and (d) the mean values of these four measurements
72 Chapter 4. The multi-shot target system FIGURE 4.12: Example of the intensity profile of the backscattered beam and its analysis. Inset: image of the backscattered beam. are depicted. The resulting curves from Method I, in panel (a), exhibit a very good consistency between them, regardless of the target reflectivity. However, for distances greater than 100 µm with respect to the zero position in the negative direction a certain saturation can be observed (see Fig. 4.14). This may be attributed to an aberration introduced by the optical arrangement. The calibration curves shown in panel (c), corresponding to Method II, present a greater dispersion in the spot size determination, specially noticeable for the farthest regions of the focal scan (±100 µm). For these regions, the backscattering beam intensity profile was weak and slightly inhomogeneous, so the Gaussian fit was not as reliable. As shown in panels (b) and (d) in Fig. 4.13, the calibration curve, namely the focussing beam profile, can be adjusted to a parabolic fit over a range of about 1 - 1.5 Rayleigh lengths around the zero position. From that point on each direction, the divergence can be fitted to an increasing or decreasing linear profile. The fit parameters for both Methods can be found in Table 4.1. The correction procedure was then evaluated by positioning the target corrected plane at a fixed distance from the zero position and measuring the backscattering beam size for the corrected target positions. Any deviation in this positioning would result in a modification of the retrieved beam size at the camera. The fixed distance was not set to zero (focal incidence), as it would be difficult to determine the direction of the deviation and changes in the spot size,
4.3. Target characterisation 73 FIGURE 4.13: Calibration - Methods I & II. but to a certain offset within the linear regions of the focussing profile (>15 µm or <-15 µm). For each corrected target position, an image of the backscattering beam size was stored and analysed according to Methods I and II. From the beam size values and the focussing profile calibration, the relative distance with respect to the zero position could be calculated for the whole map, and compared to the fixed distance. To reduce the amount of time taken on each measurement, only one of each five map points were measured. The results, for the two analysis methods and for various offsets, along with the correction verification measured by the distance sensor, are shown in Fig. 4.15 (a - d) and Fig. 4.16 (a - c). All the plotted curves have been subtracted by its mean value. The calculated standard deviation, between 4.5 and 7 µm for Method I and between 5 and 9.5 µm for Method II, is slightly greater than for the sensor measurement (∼3.5 µm), but still within the Rayleigh length
74 Chapter 4. The multi-shot target system FIGURE 4.14: Example of a non-saturated (left) and a saturated (right) images of the reflected beam at +150 µm and -150 µm, respectively. TABLE 4.1: Calibration curves fit parameters. Linear fit: RMS =mf +n; parabolic fit: RMS =af2+bf +c Linear fit Parabolic fit Linear fit m n a b c m n Method I -2.5 15.4 0.1 0.03 26.9 2.8 10.3 Method II -2.6 0.8 0.09 -0.03 19.7 2.7 -1.6 of the L2A2 system. The dispersion also seems to increase for the shiny targets. Fig. 4.16 (d) directly compares the results from Methods I and II for the same measurement, showing great consistency between them. The mean difference between curves from Method I and II is smaller than 5 µm. However, some of the points from Method II present a dispersion of about 2 - 3 times the standard value. For these measurements, the Gaussian fit applied in the calculation only fitted a part of the intensity profile corresponding to one or more peaks coming from the micrometric structure pattern of the target surface. Overall, the correction verifications measured both with the position sensor and with the set-up presented in this section are in good agreement. Thus, the correction and positioning procedure, used in the experiments described in the following chapters, can be validated.
4.3. Target characterisation 75 FIGURE 4.15: Comparison between map and methods
76 Chapter 4. The multi-shot target system FIGURE 4.16: Comparison between map and methods (cont.)
83 Chapter 5 Laser-driven ion acceleration The structure of this chapter is separated into two experimental campaigns performed under the extent of this work: at the Laser Laboratory for Acceleration and Applications (Sect 5.1) and at the Centro de Láseres Pulsados (Sect. 5.2). Within each section, the experimental set-up and the diagnostics used in each experiment are described in Sects. 5.1.1 and 5.2.1, respectively. Results are reported in Sects. 5.1.2 –5.1.3 for the experiment at the L2A2, and in Sects. 5.2.2 – 5.2.3 for the experiment at the CLPU. After the experimental sections, Sect. 5.3 addresses the Particle-In-Cell simulations on particle acceleration carried out during this thesis, while Sect. 5.4 establishes a comparison between results from the experiments and the simulations. Final conclusions are given in Sect. 5.5. 5.1 Experiments at the Laser Laboratory for Acceleration and Applications The current experimental campaign at the Laser Laboratory for Acceleration and Applications (L2A2), covering the whole extent of this thesis, is focussed on the development and commissioning of a long-term operation ion source. This comprises the development of the multishot target system, described in Ch. 4, the optimisation of the STELA laser performance, and the complete characterization of the accelerated ion beam. The following sections describe the outcome of the initial phase of the commissioning of the facility since its construction. Hence, the results and methodology presented here correspond to the first experimental measurements
84 Chapter 5. Laser-driven ion acceleration and are not completely optimised. As an ion source intended for multi-shot operation —in particular for radioisotope production—, special interest relies on the shot-to-shot and long-term stability. 5.1.1 Experimental set-up Off-Axis Parabola (OAP) Magnets ToF Protons/ions Lasers Target assembly Ti:Sa 800 nm, 35 fs, 1.2 J (2m) CMOS Camera Microscope objective (M.O.) HeNe 640 nm Vacuum chamber FIGURE 5.1: Chamber scheme. A scheme of the experimental set-up at the L2A2 experimental campaign is shown in Fig. 5.1. Inside the interaction chamber, laser pulses of up to 1.2 J-pulse energy (0.9 - 1 J on target), around 30 fs-pulse duration (FWHM), p-polarization, and 800 nm-wavelength were focussed with a 45◦,f/2.8 off-axis parabolic mirror (OAP) down to a ∼4µm-diameter spot size, reaching intensities of above 1·1020 W/cm2. The targets were µm-thickness Al and Mylar foils placed on the multi-shot target system described in the previous chapter. The target correction and positioning procedure was applied, ensuring the shot-to-shot positioning of the target surface at laser focus with a few micron accuracy at the laser repetition rate. An auxiliary HeNe laser at 640 nm was coupled to the optical path of the Ti:Sa laser for the alignment of the distance sensor and the targets. The beam transport optical arrangement, consisting of four mirrors with
5.1. Experiments at the Laser Laboratory for Acceleration and Applications 85 a reflective coating for near-IR and equipped with micron-accuracy actuators, allowed for the precise alignment of the laser beam arriving at the OAP. The initial tests, both for single-shot and multi-shot operation, were performed with the first version of the target wheel (Fig. 4.2 (a)). For the major part of the commissioning campaign the long-slot version (Fig. 4.2 (b)) was used, and a few measurements were carried out using the individual-holes version (Fig. 4.2 (c)) at pulse rates up to 3.3 Hz. The upgraded version for 10 Hz-operation (Fig. 4.2 (d)) was being tested within the last month of this work. A time-of-flight (ToF) system was used as the main diagnostic tool during the ion acceleration experiments. Being placed at 2 meters-distance behind the acceleration target inside a vacuum tube (see Fig. 5.1), it was used to measure the flight times of the accelerated ions. The ToF device consisted of the scintillator detector described in Sect. 3.2.3. The PMT was connected to a fast oscilloscope (Yokogawa DL9140 or Tektronix MSO64) to control the data acquisition and to visualize the PMT output signals. In order to reduce the external light noise in the detection system, the scintillator piece was covered by an aluminised Mylar sheet of 2 µm thickness. Saturation of the PMT was avoided by placing a neutral density filter OD1 between the photomultiplier and the optical fibres. A dipole magnet system was located inside the vacuum tube, close to the scintillator detector, to deviate electrons coming from the acceleration target. The whole experimental set-up (laser, beam line, chamber and ToF) was maintained under high vacuum conditions (10−5– 10−6mbar) during the measurements. Target alignment at the laser focus A secondary laser line impinging at the centre of the ToF detector and propagating along the normal direction with respect to the targets surface was firstly defined using a leak of the HeNe auxiliary laser at one of the alignment mirrors (see Fig. 5.1). The focus of the main laser beam line, coming from the OAP, was then pre-aligned to this secondary line, thus establishing the TCC location at the point where the two laser lines approximately crossed each other. For the first part of the experimental campaign at the L2A2, the positioning of the target surface at the TCC was performed via the speckle technique[106]. This technique is based on the analysis of the speckle pattern produced by the reflection of the laser beam on the target surface. By moving the target along the propagation direction of the laser beam coming from the OAP, focal incidence conditions were achieved when the size of the speckles reached its maximum. An example of this principle is shown in Fig. 5.2. In this way, the first impact
86 Chapter 5. Laser-driven ion acceleration +300 µm+100 µm~0 µm -100 µm -400 µm FIGURE 5.2: Speckle pattern for a focal scan. position of the three-dimensional surface map was positioned under the auxiliary laser from the OAP, and then the target was displaced at minimal steps of 1 µm along this direction until the laser focal position was found. This procedure was performed in air, and then a certain offset of ∼20 µm in the laser incidental direction was applied in order to compensate both the drift of the laser focus in vacuum conditions and the difference in the focalisation between the visible and the IR laser. This drift was estimated by comparing the position of the laser focus for three cases: the HeNe laser in air, the Ti:Sa laser in alignment mode in air, and the HeNe laser in vacuum. At a certain point in time of the experimental campaign this positioning method was upgraded to a rear-imaging system, assembled inside the vacuum chamber as depicted in Fig. 5.1. This optical arrangement consisted of a microscope objective (MO), placed behind the target wheel orientated to the laser beam coming from the OAP, mounted on a motorised linear stage moving along the same direction. In order to determine the location and the spot size of the laser focus, the focussing laser beam after the OAP was collimated by the microscope objective and retrieved by a CMOS camera located at a fixed distance outside the interaction chamber. By displacing the MO within the range of the stage, the TCC position could be found and the size of the laser focus could be retrieved through the comparison with a USAF calibration target (Fig. 5.3, panels (a) -(c)). By means of a MATLAB code, its effective area above the FWHM
5.1. Experiments at the Laser Laboratory for Acceleration and Applications 87 threshold could be measured, as depicted in panel (b) in Fig. 5.3. In this example, the obtained spot size is about 2.5 µm in diameter, and the averaged intensity results in ∼5·1020 W/cm2. FIGURE 5.3: (a) laser focus. (b) Area of the laser focus above the FWHM in intensity. (c) USAF calibration target. (d) target rear-side surface Once the TCC position was determined, the same optical system was used for the positioning of the target at the laser focus. The surface of the first point of the target 3D-map was placed under the focussing beam path, thus the microscope objective was aiming at its rear face. The target was then displaced along the laser incidental direction with micron accuracy until the image of the rear side of the target was resolved in the CMOS camera (Fig. 5.3 (d)). An additional offset accounting for the foil thickness was applied. This standard procedure is valid both in air and vacuum conditions. In fact, it allows for the measurement of the drift of the laser focus during the vacuum process and its correction. Triggering and synchronisation As introduced in Ch. 4, a triggering and synchronisation procedure was developed in order to automatically perform the positioning of the target surface at the laser focus at the operation
88 Chapter 5. Laser-driven ion acceleration 10 Hz; 0.75 ms; 5 V Up; 5 V P# +delay Laser clean room Experiment area Laser shutter Motion controller Control software Arduino Cam Other diags. PLC 1. 1. 2. 3. 4. 5. FIGURE 5.4: Trigger scheme at L2A2 experiments. FIGURE 5.5: Synchronisation scheme at L2A2 experiments. rate. This procedure was performed by the control software, and consists of a master-slave configuration at which an Arduino unit and the stages motion controller function as the master and the slave elements, respectively. A TTL (transistor-transistor logic) trigger signal of duration ∼1 ms was emitted by the laser system in advance of each laser pulse by 5 ms. This signal was continuously monitored by the Arduino unit, which in turn emitted a delayed trigger to the other devices. In the case of the long-slots target wheel, after selecting via software which slots were about to be shot and generating the corresponding PLC motion programs, the implemented trigger system performed the following operation loop (depicted in Fig. 5.4): 1. The motion program of the first slot is uploaded and executed. The motion controller moves
5.1. Experiments at the Laser Laboratory for Acceleration and Applications 89 the target to the initial position of the current slot. When the movement is completed, the control software sends a command with the number of shots (P#) to the Arduino unit. 2. The Arduino takes the next pulse of the laser trigger signal and sends a rise-edge signal to the laser shutter and the motion controller. The duration of this signal depends on the number of shots of the current slot. 3. &4. The laser shutter is opened for the span of the signal. The motion controller receives the Arduino signal and then moves the target to a new impact position every 100 ms. 5. The Arduino sends a delayed signal to some diagnosis devices. 6. When the whole slot is completed, the Arduino signal goes down and the shutter is consequently closed. The next PLC motion program is uploaded and executed, and the controller moves the target to the initial impact position of the next selected slot. The functioning of this target wheel is entirely designed for an operation rate of 10 Hz within each slot. For the target wheels with individual holes, the trigger signal of each shot is monitored and used to start each individual movement, instead of only the first one of the sequence. A schematic representation of the temporal synchronisation of this operation is shown in Fig. 5.5. For repetition rates below the maximum value (fr/2, fr/3, fr/4, etc), a command containing the fraction with respect to the laser rate is sent to the Arduino (F2,F3,F4, etc, respectively) before each series. This operation rate can be selected by the user via the control software, along with the number of shots of the current irradiation series which is equally provided by means of the pertinent (P#) command. Within irradiation, the Arduino then sends a separated trigger signal to the shutter and the motion controller for each individual laser pulse at the selected operation rate. The duration of this signal is sufficient to allow for a single pulse each. Functioning at 5 Hz (fr/2) is in principle not achievable as the shutter cannot perform the closeopen operation within 200 ms. On the other hand, for the case at 10 Hz using the upgraded version of the long-slots wheel, the schemed triggering procedure for the initial tests is similar as for the target wheel with long slots. In this way, a single rise-edge signal is sent to the shutter for the entire extent of the irradiation series, and the positioning is automatically performed by the stages controller by executing a PLC motion program. By the time of writing, no change of sector within the same series at this repetition rate is neither possible. Further programming, both for the control
90 Chapter 5. Laser-driven ion acceleration software and the Arduino unit, will be required in order to achieve a single irradiation series of the whole target wheel at 10 Hz. 5.1.2 Ion beam characterisation The commissioning experiments at the L2A2 facility aimed to the complete characterization of the accelerated ion beam, in terms of its angular divergence, species composition, and spectral distribution (cut-off energy, temperature, and flux). This study, still ongoing, was performed for targets of different materials and for a range of thicknesses between 1 and 12 µm, in order to evaluate the scaling of the ion energy with these parameters. Targets thinner than 1 µm were expected to be significantly affected by the ASE component of the laser pulses or the prepulses, hence decreasing the ion acceleration efficiency. FIGURE 5.6: ToF signal and corresponding proton spectrum. Fig. 5.6 depicts a typical signal registered by the ToF detector (left) and the reconstructed energy distribution (right) according to Eqs. 3.5 and 3.7. This measurement was obtained by irradiating a 12 µm-thickness aluminium foil with a laser pulse of 0.9 J and 35 fs, focussed onto a non-optimised 24 µm-diameter spot. The spectral distribution of the detected beam shows the expected maxwellian-like distribution with a sharp cut-off in the high energy limit. In this case, and for the analysis throughout this and the following sections, protons were assumed as the dominant and sole ion species. A Thomson parabola detector is currently being under construction and calibration at the L2A2 for ion species discrimination. Once this diagnostic is operating, a cross-correlation with the data from the ToF detector will be possible.
5.1. Experiments at the Laser Laboratory for Acceleration and Applications 91 As introduced in Ch. 2, the angular divergence of laser-accelerated ions depends on the particle energy, being broader for the lower region of the energy spectrum. Due to this, the slope —i.e., the temperature— of the energy distribution obtained from the detector measurement varies with respect to the spectrum considering the entire ion beam, depending on the solid angle covered by the detector. The ion angular divergence can be described by a Gaussian-like distribution (Eq. 2.30) whose FWHM, or standard deviation, depends on the energy following a linear (Eq. 2.31) or a parabolic (Eq. 2.32) behaviour. According to this, the number of counts of each energy bin iof the spectrum must be corrected with a solid angle factor given by fi Ω=Ωi tot Ωi det =Rtot gi(θ) sin θdθ Rdet gi(θ) sin θdθ (5.1) From that, Ni tot =Ni det ·fi Ω(5.2) where Ndet is the particle number per bin of the spectrum measured at the detector, that subtend a solid angle Ωdet, and Ntot corresponds to the particle number per bin of the spectrum evaluated in the entire solid angle of emission Ωtot. Other commonly extended units for displaying the particle number of the spectral distributions, or flux, are MeV−1·srad−1. This conversion can be obtained by simply applying the solid angle of the detector, Ωi det, to each bin of the spectrum, as Ni tot [MeV−1·srad−1]=Ni det/Ωi det. Due to the absence of experimental measurements on beam divergence, a typical profile having a half-opening angle of ∼10◦at E=Emax and ∼30◦ at E= 0.2Emax was considered[107]. For the 25×25 mm2scintillator located at 2 meters from the ion source, this assumption leads to a solid angle correction as depicted in Fig. 5.6. The blue curve represent the spectrum retrieved by the ToF detector, while the green and the red curves correspond to the respective linear and parabolic corrections. It can be noticed the change in the slope of the corrected energy distributions. To perform a quantitative comparison of this correction, those spectra were fitted to Eq. 2.26 to obtain their characteristic temperature. As an example, the fit to the energy spectra shown in Fig. 5.6 (right) is depicted by the dashed lines in the same figure. The parameters of these fits are displayed in Table 5.1. A variation of a factor of 4.5 can be observed in the calculated temperatures of the base and corrected spectra. As will be seen through following sections and
92 Chapter 5. Laser-driven ion acceleration TABLE 5.1: Spectral parameters for the base and corrected energy distributions. N0Te(MeV) Emax (MeV) Base 1.74·1010 0.114 1.65 Linear 2·1011 0.05 1.65 Parabolic 2·1011 0.04 1.65 chapters, a precise identification of this spectral parameter is fundamental for some applications requiring absolute calibration, as for example radioisotope production. The same analysis as detailed in these paragraphs was applied to the experimental data obtained at different laser shots and series, for the comparison in regard to the multi-shot stability of the ion source. 5.1.3 Proton source stability To validate the shot-to-shot stability and the repeatability of our ion source, and thus reinforce the reliability of the target correction procedure, several series of multi-shot irradiations were performed. For the initial tests, up to 24 consecutive shots at 10 Hz were achieved using the first version of the target wheel (Fig. 4.2 (c)), holding 12 µm thickness aluminium foils. The laser parameters for these series of irradiations were the same as for the spectrum shown in Fig. 5.6. In this case, the impact positions were defined along two parallel rows at each slot, for a distance of 1000 µm between positions within the same row and of 750 µm between rows. During the irradiation, the motorized stages were synchronized with the arrival time of the laser pulses on target at the laser repetition rate, 10 Hz, according to the triggering procedure described in Sect. 5.1.1. The left panel in Fig. 5.7 depicts the energy spectra of the proton bunches for the first twelve consecutive shots along a single row. All the spectra exhibit a coherent maxwellian-like trend, similar both in temperature and cut-off energy. Only for a few shots the cut-off energy and in some cases the temperature seems to be smaller. The inset in the left panel in Fig. 5.7 shows a picture of one of the aluminium foils after the irradiation. In this image one can clearly observe the holes produced by the laser impacts along the two rows. The holes have a average radius of around 500 µm. In order to quantify the reproducibility of the proton source, the temperature and the cut-off energy of the proton energy spectra were retrieved by fitting those spectra to Eq. 2.26, as in the
5.2. Experiments at the Centro de Láseres Pulsados 99 angle. It consisted of a MCP from Jordan TOF Products, having an active area of 25 mmdiameter, attached to a cathode to collect the excitation electrons. The diameter of the microchannels was 10 µm, and the centre-to-centre separation was 12 µm. An aluminised-mylar filter of 2 µm-thickness was placed at the MCP to avoid saturation and for external noise reduction. This detector was not calibrated in particle number so it could solely provide ion energy data. For the series of measurements using the catcher targets for neutron generation, only the TP was in principle available for ion diagnostics. The catcher samples (LiF or Cu) had a pinhole in their centre, therefore only the ions emitted at ∼0◦could be detected, by the TP in this case. However, due to the accumulation of debris from the pitcher target during long multi-shot series, the pinhole could be partly obstructed within the series and thus a part of the ion beam blocked. After a certain amount of debris material was accumulated, it could fall off by its own weight. This could lead to a significant and progressive attenuation, or even vanishing, of the traces at the TP during the multi-shot series. Target alignment at the laser focus The location of the TCC inside the interaction chamber was predefined by the tip of a thin needle, mounted on a linear stage. At the beginning of the experiment and before the assembly of the target system inside the interaction chamber, the high power or the auxiliary laser were focussed to this tip by slightly adjusting the OAP alignment. This procedure was monitored with a microscope objective (MO), mounted on top of two linear stages, one horizontal and one vertical to the board of the chamber. Once the laser focus was located at the predefined TCC, the encoder positions of the microscope stages were stored. On each day during the experimental campaign, any possible drift of the laser focus was accounted for by updating these encoder positions. The left panel in Fig. 5.11 shows an image of the focal spot of the high power laser in alignment mode, retrieved by means of this procedure on one of the experiment days. A visible diode laser was coupled to the optical path of the high power laser as a reference for the target alignment. Placing the microscope objective at this position and moving the target wheel along its normal direction, the point over the sector plate of the target wheel for which the surface was resolved by the objective defined the reference point for the alignment of the position sensor (Fig. 5.11, right panel). A second visible HeNe laser was pointed at this reference —the focus
100 Chapter 5. Laser-driven ion acceleration Ref. M.O. FIGURE 5.11: Image of the reference point defined by the microscope objective (MO). of the MO— as a visual guide for the following steps. After determining the coordinates of the reference point, the 3D mapping procedure of the entire wheel was performed. The alignment of the targets at the laser focus was carried out by means of the same optical system. The target surface for the first impact position of the 3D map was positioned under the optical path of the auxiliary beam, i.e., centred in the microscope field of view. The target was then moved along the incidence direction with micron accuracy until the surface was resolved by the MO. As described in Ch. 4, this position was then set as the focal reference position to which the rest of the corrected map points were referred. The reference position was reevaluated once in vacuum conditions on each experimental day that used the same surface map, and readjusted if necessary. EM pulse and relay system Due to the high amount of energy coming from the laser pulses deposited on target, a huge electromagnetic pulse was produced at the laser-plasma interaction. This EM pulse propagated through the wired connections affecting all the electronic devices within a few meters around the interaction point. This phenomenon is a common output in high power laser facilities. For most of the devices, the arrival of the EM pulse translated to a certain recovery time for which the device could not be operated. Other devices, on the other hand, were restarted or completely shut down. This circumstance was produced for each laser pulse at the operation repetition rate. To overcome this issue and prevent the motion controller from not working properly (or being damaged), a relay system was designed and implemented. For each of the three moving
5.2. Experiments at the Centro de Láseres Pulsados 101 stages and the encoder connections, a relay unit was inserted between the stage or encoder and the motion controller, properly shielded with aluminium and lead outside the interaction chamber. Each relay unit consisted of an Arduino board (Uno or MEGA) equipped with four relays by Arduino. In the case of the moving stages, two of these relays were bypassing the cables corresponding to the internal induction spools responsible of the movement, in order to prevent any undesired retro-induced current produced by the EM pulses. For the encoder cable, on the other hand, two relay units were used to interrupt its entire connection to the motion controller. On activation, the relays were programmed to disable the wired connections and the communication between the controller and the devices for a certain number of milliseconds. During the irradiation, the operation of the relay system was automatically performed by the control software of the target assembly, concerning the synchronization with respect to the arrival of laser pulses and the positioning movements (see section below). As this issue was not addressed before at the L2A2 and could not be tested there, a significant part of the development of this system took place during the experiment itself. Specifically, the response of the stages and the motion controller to these huge EM pulses. It was early found that most of the times the encoder position of the moving stages was reset to zero —i.e., lost— after the arrival of each laser pulse, so the positions corresponding to the 3D map of the target, either corrected or not, were no longer valid. This might happen even with the relay system connected and working. In some other cases, the motion controller was permanently frozen until reboot, which lead to the interruption of the current irradiation series. The former issue was solved by storing the stages encoder position in the control software memory at the action of the relay system. After the arrival of the laser pulse, that position was recovered by means of the pertinent commands sent to the motion controller. No attempt of shooting the laser without shutting down the connections with the relay system was performed. Triggering and synchronisation The synchronisation scheme for the positioning of the targets with respect to the laser pulses in the experimental campaign at the CLPU differed from the one described in Sect. 5.1.1 for the experiments at the L2A2: the operation of the relay system was included, the start of the irradiation series or single shots was performed by the laser team —not by the user via the control software— and the main trigger signal came from the laser system and not from an
102 Chapter 5. Laser-driven ion acceleration Arduino unit as in the master-slave configuration detailed in Sect. 5.1.1. In this case, the TTL trigger signal corresponding to each laser pulse was monitored and used to start each movement. These signals had a duration of about 10 ms, and preceded the laser pulses by 100 ms. FIGURE 5.12: Trigger temporal scheme at CLPU experiments. Using the individual-holes target wheel, the number and the index of shot points about to be shot were selected via software. During the irradiation, the implemented trigger system performed the following operation loop: • The motion controller moves the target to the first impact position of the series. • The control software starts monitoring the trigger signal coming from the laser system. • On trigger, the relay system disables the connection between the stages and the motion controller. The current position of the stages is stored in memory by the control software. • The laser pulse impinges on the target and the EM pulse is produced. • The relay system enables the connection between the stages and the motion controller after a fixed time interval. • The control software waits for a certain dead time and then recovers the stages position, which may be lost due to the EM pulse. • The motion controller moves the target to the next impact position of the series.
5.2. Experiments at the Centro de Láseres Pulsados 103 The timing scheme of this loop is represented in Fig. 5.12. The dead time between the reconnection of the relays and the beginning of the following movement was introduced to account for the recovery time of the motion controller after each laser pulse. Any instruction sent to the motion controller before the end of that dead time, as the position recovery commands, was ignored. Its duration was found to be dependent on the laser pulse energy, i.e, on the intensity of the EM pulse. The minimum values were 250 ms for 6 and 12 J laser energies, 3000 ms for 20 J and between 4000-5000 ms for >25 J. As the movement time was fixed to 250 ms, the only difference between each case was the duration of this waiting time. Thus, the operation rate for each energy was limited to 1, 0.2, and 0.1 Hz, respectively. Some stochastic errors were still produced, for which the positioning during an irradiation series failed after an arbitrary laser shot. Even being aluminium- and lead-shielded, the final conclusion was that the EM pulse was slowing down the Arduino units of the relay system as well. The reconnection of the relays was then produced later than expected and the following instructions given to the motion controller were not properly applied. The control software was updated daily during the experiment to minimise these failures. 5.2.2 Ion beam characterisation Aluminium foils of 7 µm-thickness were irradiated with laser pulses of energies ranging from 6 to 25 J. The nominal energies for operation were 6, 12, 17, 20, and 25 J, and a dispersion of about 13% was observed for each central value. At the beginning of each day of the experimental campaign, several single-shot measurements on ion acceleration —i.e., without catcher— were performed at some of the nominal laser energies to characterise the beam properties and its scaling with the pulse energy. Several multi-shot series of different duration, repetition rate, and laser energy were performed as well to evaluate the stability of the ion source and the performance of the target assembly. Within the entire experimental campaign, protons with peak energies up to 15 MeV were achieved both in single-shot and multi-shot series. Considering the experimental parameters both of the laser system and the target, TNSA was the predominant ion acceleration mechanism. Single detector measurements The species composition of the ion beam, as retrieved by the measurements at the TP, is illustrated in Fig. 5.13 (left panel), showing the expected traces due to protons (+H) and a collection
104 Chapter 5. Laser-driven ion acceleration of carbon (C), nitrogen (N), and oxygen (O) ions in different degrees of ionisation. The proportion between each species varied shot-to-shot as the relative composition of the contaminant layer at the rear side of the acceleration foils may differ from target to target. Nevertheless, the trace produced by protons was typically the most intense one. 3.80 kV/cm 2.65 kV/cm 10.62 MeV 10 – 15 MeV FIGURE 5.13: Species composition of the ion beam accelerated by a 25J laser pulse (left). Observed superposition of the traces of different ions (right). The superposition between the traces due to protons and other heavier ions supposed a complication in the data analysis of several measurements, specially for the highest nominal energies of the laser pulses. The degree of superposition was dependant on the electric field intensity at the TP plates. The right panel in Fig. 5.13 depicts two signals measured at different days for different plate voltages at the same laser energy. It can be clearly seen that, for the case at 3.80 kV/cm, the proton trace is well separated from the trace produced by heavier ions. In this case, the cut-off energy of the protons can be precisely resolved at 10.62 MeV. On the contrary, in the signal measured at 2.65 kV/cm, the two traces overlap within the high energy region, hence the proton cut-off energy cannot be determined but over a range of several MeV. This led to a certain uncertainty in the ion maximum energies for some series of measurements. The electric field at the TP was set as higher as possible during the irradiations. However, during long multishot series, plate voltages above a certain level caused the TP plates to go down, presumably
5.2. Experiments at the Centro de Láseres Pulsados 105 affected by the EM pulses from the laser-plasma interaction. FIGURE 5.14: Proton spectra retrieved from the TP traces for various laser energies. The energy spectrum of the accelerated ions was retrieved from the TP traces by using a MATLAB code (TPA) developed by A. Alejo. Fig. 5.14 (left panel) depicts the energy spectra corresponding to protons for various laser energies measured at single-shot irradiations. Results show the typical maxwellian distribution at multi-MeV order energies. As expected, increasing the pulse energy leads to an increase in the cut-off energy of the accelerated proton beam. For this particular set of measurements, a linear dependence of the proton maximum energy with respect to the laser energy is observed. The TP, located at 0◦and 0.72 m from the TCC, had a pinhole of 200 µm-diameter, thus only a part of the entire proton beam was detected. The solid angle factor at the TP was evaluated using Eqs. 5.1 and 5.2, considering a Gaussian-shaped angular distribution with a linear or a parabolic dependence on the particle energy given by Eqs. 2.30 –??. The corrected spectra, i.e., the assumed distribution of the entire proton beam, were then fitted to Eqs. 2.26 in order to obtain the characteristic temperature. An example is shown in the right panel in Fig. 5.14, where a raw spectrum (blue curve) —as retrieved from the TP— is depicted along with the corrections considering both angular profiles (green and red curves for linear and parabolic divergences, respectively). The three spectra are normalised to the same total number of counts to facilitate the comparison. A significant variation in the slope of the corrected distributions with respect to the base spectrum can be clearly observed. As the disagreement between both corrections is below 10% for the high energy range, only the linear divergence profile will be considered through the following analysis. Concerning the acceleration of heavier ions, due to the fact that most of their traces at the TP were superposed
106 Chapter 5. Laser-driven ion acceleration within an extensive energy range and that the relative intensity of each line varied on a shot- to-shot basis, the retrieval of their spectral distributions was not trivial and was not attempted. Instead, the cut-off energy of a few species was calculated for some multi-shot series, in regard to the target stability. FIGURE 5.15: Proton spectra retrieved from the ToFs (i3M and CLPU) traces for various laser energies. The raw signals measured by the ToF detectors are depicted in Fig. 5.15. Panels (a) and (b) show the results from the detector developed at the I3M for the indicated nominal laser energies. As during the first experimental weeks the detector was a placed at a shorter distance from the TCC (2.39 m) and low or none optical filters were used, the measurements from these weeks (panel (b)) are visibly saturated. In addition, the signal produced by the ion bunch is overlapped with the decay of the gamma-flash. This was partly solved by increasing the ToF distance to 4.545 m and the optical density of the filters in the last week of campaign. This improvement is reflected in the signals shown in panel (a), measured during this week, for which the ion bump is separated and no saturation is observed. Despite this, some of the raw signals, principally for
5.2. Experiments at the Centro de Láseres Pulsados 107 laser energies above 20 J, exhibited an artefact between the gamma-flash and the ion bump, as can be seen in the blue signal in (a) (25 J). In some cases, these artefacts were superposed to the signal due to ions, hence complicating the analysis. The origin of such spurious signals could not be identified by the time of writing this work. The calibration of this detector, mentioned in Sect. 3.2.3, was in principle not applicable to the measured data as it was performed for a range of ion energies between 1 and 3 MeV, far below the typical experimental energies within this campaign. As for the experiments at the L2A2, protons were assumed to be dominant and the fastest species reaching the detector, therefore the initial rise of the ion bump in the raw signals —thus the cut-off energy— was attributed to them. Both this maximum energy and the signal amplitude, i.e., the particle number although the detector was not calibrated, seem to escalate with the laser energy. Panels (c) and (d) in Fig. 5.15 present the results for similar measurements retrieved at the ToF detector developed at the CLPU. In comparison with the signals obtained with the ToF from the I3M, this detector shows better time resolution and significantly experiences less saturation. In this way, the gamma-flash is well resolved and completely separated from the ion bump for the case at 25 J, in contrast the equivalent signal displayed in panel (a). As for the previous cases, a scaling of the main beam parameters with respect to the laser pulse energy can be observed. Some of the measured raw signals exhibit a second bulge due to heavier ionic species. This is illustrated in panel (d), showing the presumed ion contributions in a different color in each signal at the indicated laser energies. Besides, no in-depth study on heavy ion laser-driven acceleration was performed within this work. Given that only reactions induced by protons were contemplated for neutron generation and radioisotope production, no attempt on optimising the ion acceleration efficiency was regarded. On the other hand, the analysis of the data from both ToF systems, regarding the temperature calculation, was limited to the raw spectra. The detectors were not aligned to the ion 0◦-emission direction but placed at ∼10 and ∼20◦, thus complicating the estimation of the solid angle factor from the angular divergence profiles, as the detected cut-off energies were not the maximum energy of the accelerated proton beam. This maximum energy could be in principle obtained from the corresponding TP spectra, yet no clear angular cross-correlation between detectors was found, as discussed below. Moreover, a variable and not negligible component of the ToF signals was due to the heavier ion contribution. For these reasons, the solid angle corrections were not as conclusive and the temperature of the raw, base spectra were only examined for comparison, concerning shot-to-shot stability.
108 Chapter 5. Laser-driven ion acceleration Comparison between detectors FIGURE 5.16: Scaling of the proton cut-off energies given from the signals retrieved at the three main detectors (top), and proton cut-off energies measured at the TP and the two detectors for the same series at 12 J and 1 Hz (bottom). A direct comparison of the three aforementioned diagnostics is shown in Fig. 5.16. The cut-off energy of the laser-accelerated protons from the same single-shot series at various pulse energies is depicted in the upper and lower panels, corresponding to two different measuring days (18/10/22 and 21/10/22, respectively). Solid diamonds represent the values retrieved from the TP traces, open circles the measurements obtained at the ToF from I3M, and solid squares the same values as given by the ToF from CLPU. Each color depicts each laser pulse energy: red for 6 J, orange for 12 J, green for 17, and blue for 25 J. The scaling between both parameters can be directly observed for the three sets of data in both panels. In regard to the upper panel, the comparison between the average cut-off energy measured at the three devices seems to be
5.2. Experiments at the Centro de Láseres Pulsados 115 TABLE 5.4: Correlation between the maximum energy and the temperature. Exp. growth: T0T1τ R2χ2 T0+T1·exp(Emax/τ)(MeV) (MeV) (MeV) Base -0.012 0.016 3.95 0.908005 0.056405 Linear -0.032 0.031 6.91 0.914137 0.006140 Parabolic: T0T1T2R2χ2 T0+T1·Emax +T2·E2 max (MeV) (-) (MeV−1) Base 0.18 -0.061 0.0062 0.906251 0.057480 Linear 0.023 -0.0051 0.0013 0.914031 0.006148 Linear: T0T1R2χ2 T0+T1·Emax (MeV) (-) Base -0.22 0.048 0.756118 0.149532 Linear -0.059 0.017 0.859358 0.010058 a parabolic or linear polynomial correlation. Table 5.4 summarises the parameters of each function obtained from the fits, both for the base and the corrected data. The R2and the χ2coefficients from a goodness-of-fit analysis for each of the fits are listed in Table 5.4 as well. The highest values of the R2coefficient are obtained for the exponential growth dependence on the data —slightly greater than the parabolic dependence, about less than a 1%—. The comparison between the χ2coefficients leads to a similar conclusion. Hence, the exponential growth dependence on the data can be considered as the best fit, which is also plotted in Fig. 5.20. While both parameters are expected to escalate with the peak intensity of the laser pulses, such a correlation between them has not been reported in literature. It can be compared with the theoretical estimations given by the isothermal expansion model (see Sect. 2.3.1) and the results obtained in the Particle-In-Cell simulations performed within this work (Sect. 5.3). This comparison will be studied in detail in Sect. 5.4. 5.2.3 Ion source stability The performance of the multi-shot target assembly during the experimental campaign was rather solid. Typically, around 400 - 500 laser shots (half the target wheel) were performed per day, for a total of ∼3700 shots within the two weeks of experiment. About 60 series of more than 10 shots in multi-shot operation were achieved for laser pulse energies ranging from
116 Chapter 5. Laser-driven ion acceleration 12 to 25 J. The highlights of the multi-shot series, only considering those having ion beam diagnostics, are: • One series of 32 shots at 12 J and 1 Hz. • One series of 180 shots at 20 J and 0.2 Hz. • Several series of ≥101 shots at 25 J and 0.1 Hz. In spite of the day-to-day variability of the laser system mentioned in the previous section, the cut-off energies and temperatures within the same measuring day present a high stability. The typical standard deviation is below the 10% in most of the series in multi-shot operation. Panels (a),(b), and (c) in Fig. 5.21 depict the proton cut-off energies retrieved from the TP traces for the three above-highlighted multi-shot series at different pulse energies and repetition rates. Panel (a) corresponds to the multi-shot series performed at 12 J-energy per pulse and 1 Hz-repetition rate. The shot-to-shot proton cut-off energies measured at the TP (solid purple diamonds), the ToF from I3M (open cyan circles), and the ToF from CLPU (solid magenta squares) are depicted. As this measurement were performed on the same day as the results in the upper panel in Fig. 5.16, it reflects the same behaviour regarding the dependence of the measured cut-off energies with the detection angle. Panels (b) and (c) represent the cases at 20 J and 0.2 Hz, and at 25 J and 0.1 Hz, respectively. FIGURE 5.21: Proton and ion stability of various series at 12, 20 and 25 J.
5.2. Experiments at the Centro de Láseres Pulsados 117 Panel (d), on the other hand, depicts the stability in the cut-off energy of another series at 25 J and 0.1 Hz and includes the results obtained for two other ion species (+4C and +6O). Aside from the signal due to protons (+H), these two species exhibit the most intense traces at the images retrieved by the TP system on that day. As both traces are superposed at the high energy range, the same edge was utilised for the calculation of the cut-off energy and the spectrum for both ionic species. Thus, the two curves in panel (d) are equal but for a different central energy per nucleon, given by the charge-to-mass ratio of each ion. It can be noticed that the range of the cut-off energies for the three series in panels (a-c) is of the same order, despite the different energy per pulse in each case. As each series was performed on a different day, this was mainly caused by the variability of the laser system discussed in the previous section. Regarding each series, the shot-to-shot oscillation may be partly originated by fluctuations in the energy and the duration of the laser pulses. According to the measured data, a standard deviation of about 1.3% and 6.5%, respectively, is calculated for these fluctuations, which may affect the cut-off energies about a overall factor of 2.5 according to Eq. 2.18. All the depicted series in Fig. 5.21 exhibit a dispersion in the cut-off energy of less than 10%, regardless of the operation rate of the target assembly and the pulse energy, for long multi-shot series of up to 180 shot points. Thus, it demonstrates the shot-to-shot stability of the proton source, and consequently of the target system and its functioning procedure. Although a micron-accuracy positioning was not required for these series, in contrast to the experimental case at the L2A2, a singular challenge for the target assembly within this campaign resided in the proper synchronisation between the laser pulses, the relay system, and the refreshment of the target surface, while handling the huge EM pulses produced at the interaction. The spectral temperature of each shot of the same three highlighted multi-shot series is shown in Fig. 5.22. Each panel in the figure depicts the temperature calculated via the fit of the base and corrected —linear— spectra from the TP to a Maxwell-Boltzmann distribution. In comparison to the observed shot-to-shot stability of the maximum energy in Fig. 5.21, the temperature presents higher data dispersion, showing standard deviations between 10 and 40%. This factor is more prominent for the temperatures estimated from the base spectra. As can be seen in the figure, specifically for the series shown in panel (c), some of the calculated values are up to a factor of 2 higher than the estimated standard deviation, indicated in the legend in each figure. Even for similar maximum energies, the shape of the spectral distributions was not homogeneous between shots and some of them exhibit a significant variation in temperature.
118 Chapter 5. Laser-driven ion acceleration FIGURE 5.22: Temperature stability of various series at 12, 20 and 25 J. Others, however, present a two-temperatures distribution near the highest energy region, thus complicating the fit to a pure Maxwell-Boltzmann exponential decay. These results, denoted as open symbols in Fig. 5.22, were excluded from the analysis by means of a χ2goodness-of-fit evaluation at α=0.05. 5.3 Particle-In-Cell simulations Particle-In-Cell (PIC) two-dimensional simulations on laser-driven ion acceleration were performed as a supplementary study to the experiments. By means of these simulations, the experimental cases within the L2A2 and the CLPU campaigns were reproduced in order to infer the scaling laws of the relevant parameters, and as a qualitative comparison to the experiemental data presented throughout previous sections. In this way, the irradiation of a thin target foil of a material of low atomic number —specifically aluminium, as used in the experiments— with a ultraintense femtosecond laser pulse at a certain angle of incidence was simulated. The simulations presented in this section were carried out by means of the Smilei code, running at the FinisTerrae II and FinisTerrae III clusters at the Centro de Supercomputación de Galicia (CESGA). The happi module from Smilei was used for the analysis of the resulting data and its graphical representation.
5.3. Particle-In-Cell simulations 119 5.3.1 Simulation parameters TABLE 5.5: Parameters for the laser-driven proton acceleration simulations, performed by means of the Smilei code, for the cases at L2A2 and CLPU. L2A2 CLPU General Spatial resolution 10×20 25×25 nm Simulation box 24×72 65×80 µm Temporal resolution 0.03 0.051 fs Simulation duration 900 1530 fs Number of patches 32×32 64×64 Target Foil thickness 2 - 12 7 µm Particles-per-cell 100 100 Initial ion density 50nc50nc Degree of ionisation +13 +4 Preplasma extension 0.05 1.32 µm Preplasma scale-length 0.5 0.5 λL Proton layer thickness 100 200 nm Particles-per-cell 900 900 Initial proton density 100nc100nc Degree of ionisation +1 or 0*0* Laser Wavelength 800 800 nm Pulse duration (FWHM) 25 250 fs Focal spot size (FHWM) 2.5 20 µm Dimensionless amplitude 9.6 1.5 - 3.9 Incidence angle 45 10 deg. *: neutral proton layer, dynamic field-ionisation activated. The implemented parameters for the simulation of the experimental conditions at the L2A2 and at the CLPU are listed in the two columns of Table 5.5. Regarding the former, the simulation box had a size of 24×72 µm2, corresponding to 1600×2400 cells at a 10×25 nm spatial resolution, comparable to the typical values reported in literature[47,49]. The temporal resolution was set to 0.03 fs, satisfying the CFL condition, for a total simulation time of 900 fs. Due to the larger duration (∼250 fs) and spatial length (∼75 µm) of the VEGA 3 laser pulses, the duration of the simulation and the box size in the longitudinal x-direction were escalated about a factor 1.7 and 2.7, respectively, so the entire pulse could enter the simulation box before reaching the target. As the computing resources would have significantly increased, the spatial
120 Chapter 5. Laser-driven ion acceleration and temporal resolutions were accordingly escalated to 25×25 nm and 0.051 fs. This corresponds to a total of 2624×3200 number of cells, that is, 65×80 µm2, and 1530 fs-duration. The size of the transversal y-dimension of the box in both cases was sufficient so the laser pulse, entering the simulation from the left boundary — the negative xbox side—, had enough lateral space from the adjacent box side at the defined incidence angle. The target foil was defined orthogonal to the x-axis and along the entire y-dimension of the box. Its thickness was fixed to 7 µm for the CLPU simulations, as in the experimental situation, and was varied from 1 to 12 µm for the simulations of the L2A2 conditions, corresponding to the range of available foil thicknesses at the facility. The initial particle density was set to 50 times the critical density nc, having a typical, reasonable number of 100 particles-per- cell. As dynamic field-ionisation would require an elevated amount of computing resources, the common approach consists of pre-ionising the material up to a certain degree of ionisation. In this way, part of the energy from the laser pulse is absorbed by the ions instead of being entirely transferred to the electrons, which would lead to a certain overestimation of their energies. Therefore, the target consisted of an aluminium foil fully ionised (+13) for the L2A2 simulation, and partly ionised (+4) for the CLPU case. The target was hence defined as a neutral plasma so the electron density newas set to ne=d·ni, being nithe ion density and dits degree of ionisation. An expanding preplasma was configured in the frontal face of the target, to account for the ionisation produced by the prepulses or the pedestal of the laser. The particle density profile of this preplasma was an exponential growth following expression ni= 50ncexp[(x−x0 Lg )−1] (5.3) where ncis the critical density, Lgthe plasma scale-length, and x0the x-position of the target foil inside the simulation box. The longitudinal extension of the preplasma was estimated from the ion sound speed (Eq. 2.2.5) for an electron temperature calculated via Eq. 2.2.23. The intensity of the prepulses or pedestal above the ionisation threshold (∼1016 W/cm2), obtained from the experimental temporal traces of STELA and VEGA 3 (Figs. 3.4 and 3.6), was utilised for the calculation of this electron temperature. The advance of these contributions with respect to the main laser pulse defined the expansion time of the preplasma. Given that this time interval is several orders of magnitude longer than the duration of the laser pulse —and therefore longer
5.3. Particle-In-Cell simulations 121 than the laser-plasma interaction—, enough for the thermalisation of the preplasma, it was set to a neutral aluminium plasma at the same ionisation degree as the target. Some simulations were performed having the preplasma composed of neutral ionised hydrogen (+1H and electrons) instead, yet no significant difference was observed. For simplicity and better computing performance, the preplasma composition was set to ionised aluminium. For VEGA 3 laser, considering the temporal trace shown in Fig. 3.6, the extension of the preplasma can be estimated as ∆x= 1.05 µm = 1.32λL. The same analysis for the STELA laser gives an estimation of ∆x = 50 nm = 0.066λL, due to its ultra-high contrast, which was approximated to a step density profile for some of the simulations[108]. The rear side of the target foil, on the other hand, was coated with a ultra-thin film of hydrogen, representing the contamination layer from which protons are accelerated trough the TNSA mechanism. The thickness of this film was set to a few times the spatial resolution of the simulation. The particle density and the number of particles per cell were increased to 100ncand 900 particles-per-cell, respectively, for improved resolution. Different approaches were considered for the simulations of the L2A2 and CLPU experiments. For the former, the hydrogen film was ionised up to a neutral plasma of protons and electrons. For the later, the film was composed of neutral hydrogen atoms and dynamic field-ionisation was activated. As detailed in the section below, the effect of these two methods on the resulting proton beam was evaluated by performing comparative simulations. No appreciable difference was found, but for varying the execution time of the simulation. Regarding the configuration of the laser pulse, a two-dimensional Gaussian pulse travelling towards the positive x-direction at the experimental incidence angle was defined. The pulse was focalised onto the target surface at half the transversal length of the simulation box, i.e., at (x0,ymax/2), down to a focal spot of 2.5 or 20 µm-diameter, depending on the simulated case. As indicated in Table 5.5, the characterisation of the laser pulses in the simulations replicated the experimental parameters present within each campaign. Silver-Müller absorbing boundary conditions for the electromagnetic fields were set at each side of the simulation box other than the laser entrance boundary. 5.3.2 Simulation results By means of the simulations presented in this section, the systematic scaling of the proton maximum energies and temperatures were studied upon the variation of several experimental
122 Chapter 5. Laser-driven ion acceleration parameters of interest, such as the target thickness or the laser pulse energy. As the main objective of these simulations is the qualitative comparison with the experiments performed within this work, as well as its extrapolation for future research, practical magnitudes and parameters were analysed. The properties of the accelerated particle beams, as well as other extensive magnitudes as the electric and magnetic fields or the particle densities, were examined at each simulation. The diagnosis tools from the Smilei code were utilised for the retrieval of these data. The energy of the protons and the electrons accelerated at the rear side of the target was measured via a screen diagnostic, placed at the right boundary of the simulation box. Each particle crossing the screen was histogrammed according to its energy and type. The duration of the simulation was sufficient to let most of the accelerated protons reach the screen. Also, the electric field and the particle densities over a two-dimensional grid centred at the target were recorded over fixed time steps within the entire extent of the simulation. FIGURE 5.23: Evolution of the electric field, the electron density and the proton density. As an illustrative example, Fig. 5.23 shows the evolution of the electric field in ˆx(Ex)(a), the electron density (ne)(b), and the proton density (np)(c) for a simulation using arbitrary parameters from the left column in Table 5.5. Each image, at four different times (0, 150, 300, and 600 fs), depicts the defined two-dimensional grid around the target foil at which each
5.3. Particle-In-Cell simulations 123 magnitude is evaluated. Colour bars indicate the value of each of them, in linear scale for the electric field, and logarithmic for both particle densities. The later are expressed in arbitrary units, proportional to the ion critical density. As can be seen in the images, the laser pulse enters from the left side of the box and impinges on the target foil, which is initially neutral. The following simulation steps can be described through the TNSA mechanism: the electric field from the laser pulse accelerates the electrons towards the target, and emerge from the rear side as a negative-charged cloud. A charge-separation field, of about 0.4 TV/m, is generated between the electron cloud and the proton film, that then accelerates the later as a sheath that propagates to the right side of the simulation box. A less efficient acceleration of both electrons and protons is observed as well in the frontal face of the target. Thus, it can be seen that the TNSA mechanism can be qualitatively reproduced through these simulations. From this reference example, the systematic study on some parameters of interest was carried out, as will be presented throughout the following discussion. Target thickness The scaling of the main spectral parameters of the proton beam with the thickness of the target was evaluated. This was motivated by the flexibility of the target system developed within this work to host target foils of different thickness or composition. Although no experimental study on this dependence nor results were presented in Sects. 5.2 and 5.3, the incoming series of experiments at the L2A2 may utilise aluminium and Mylar foils down to 1 µm-thick. Thus, aluminium foils of thicknesses 1, 2, 6 and 12 µm were simulated considering the experimental parameters at the L2A2. The size of the simulation box along the x-direction was escalated with the target thickness up to 40.96 µm, in order to maintain the distance between the rear side of the target and the diagnosis screen. This distance was sufficient so the ions could be accelerated up to their maximum energies. The results from the simulation at each target thickness are depicted in panels (a) and (b) in Fig. 5.24. Panel (a) presents the proton energy spectra for all the simulated cases, while panel (b) plots the maximum energy (green curve, left axis) and the temperature (red curve, right axis) obtained at each of them. The later was calculated by fitting the corresponding spectrum in panel (a) to Eq. 2.26. An increase of both parameters with the target thickness is expected[70] and observed. While it is not contemplated in the simulated case, target thicknesses below a certain critical value are presumably affected by the ASE component of the laser pulses or the prepulses in the experimental situation, depending on the contrast of the laser. This critical
124 Chapter 5. Laser-driven ion acceleration value can be estimated to a few hundreds of nanometres for the STELA laser, and up to 1 or 2 µm for VEGA 3. Step preplasma profile Particle number (a.u.) 10-6 10-5 10-4 10-3 10-2 Energy (MeV) 0 4 8 12 16 20 1 μm 2 μm 6 μm 12 μm Step preplasma profile Maximum energy (MeV) 0 4 8 12 16 20 Temperature (MeV) 0 0,2 0,4 0,6 0,8 1 Target thickness (μm) 0 2 4 6 8 10 12 14 Max. energy Temperature Ramp preplasma profile Particle number (a.u.) 10-6 10-5 10-4 10-3 10-2 Energy (MeV) 0 4 8 12 16 20 1 μm 2 μm 6 μm 12 μm Ramp preplasma profile Maximum energy (MeV) 0 4 8 12 16 20 Temperature (MeV) 0 0,2 0,4 0,6 0,8 1 Target thickness (μm) 0 2 4 6 8 10 12 14 Max. energy Temperature FIGURE 5.24: Electron and proton spectra from PIC simulations for various target thicknesses at L2A2. These results can be compared with the experimental measurements at the L2A2. The simulations indicate that the maximum energies obtained experimentally, up to 2 MeV for a 2.5 µm-diameter focal spot (Fig. 5.8, panels (c) and (d)), may be systematically low. Thus, for aluminium foils of 12 µm-thick, a cut-off energy of around 5 MeV would be expected. Regarding the temperature, the simulations exceed the experimental values (Fig. 5.9) about a factor of 1.4. The results from the simulations, however, may be overestimated as well, as the maximum energy of almost 20 MeV obtained for target thickness of 1 µm suggests. The comparison between these two results, as well as with data from recent publications, will be detailed in section