Food Packaging and Shelf Life 33 (2022) 100883 Available online 13 June 2022 2214-2894/© 2022 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/bync-nd/4.0/). Determination of BFRs in food contact articles: An analytical approach using DART-HRMS, XFR and HPLC-MS/MS A. Lestido-Cardama a , R. Paseiro-Cerrato b , * , L.K. Ackerman b , R. Send´ on a , A. Rodríguez- Bernaldo de Quir´ os a , ** a Department of Analytical Chemistry, Nutrition and Food Science. Faculty of Pharmacy, University of Santiago de Compostela, 15782 Santiago de Compostela, Spain b US FDA, Center for Food Safety and Applied Nutrition, 5001 Campus Drive, College Park, MD 20740, USA ARTICLE INFO Keywords: BFRs Food contact articles DART-HRMS XFR HPLC-MS/MS Migration ABSTRACT The combined use of DART-HRMS, XRF and HPLC-MS/MS to determine potential contamination with brominated flame retardants (BFRs) in several food contacts articles (FCAs) purchased in Spain was investigated. DART-HRMS and XRF were used as screening techniques for BFR identification. DART and XRF detected 100 % and 80 % respectively of the contaminated samples. HPLC-MS/MS was used for the determination of TBP (Tribromophenol), TBBPA (Tetrabromobisphenol-A) and BDE-209 (Decabromodiphenyl ether). The HPLC-MS/ MS method was validated in terms of correlation coefficient (r 2 ≥0.994), LOD (≤0.02 µg/mL) and LOQ (≤0.05 µg/mL). Method recoveries were from 80 % to 120 %. Identified FCAs contaminated with BFRs were subjected to a migration test using 20 % ethanol, 95 % ethanol as food simulants and pepper as food. Migration of the three analyzed BFRs occurred at levels ranging from non-detected to 90 μ g/kg in 95 % ethanol. 1. Introduction Brominated flame retardants (BFRs) are a group of compounds which have been extensively used in different applications such as electronic equipment, building materials, and textiles to improve their fire resistance (Kajiwara, Noma, & Takigami, 2011; Schlummer, Brandl, M¨ aurer, & van Eldik, 2005; Vilaplana, Karlsson, Ribes-Greus, Ivarsson, & Karlsson, 2008). They can be grouped into five major classes, specifically brominated bisphenols, diphenyl ethers, cyclododecanes, phenols, and phthalic acid derivatives (Pivnenko, Granby, Eriksson, & Astrup, 2017). Tetrabromobisphenol A (TBBPA), polybrominated diphenyl ethers (PBDEs), and hexabromocyclododecane (HBCD) are among the most predominant (Hyoe¨tylae¨inen & Hartonen, 2002). Brominated phenols are employed in a wide range of resins and polyester polymers (EFSA (European Food Safety Authority), 2011, 2012). TBBPA is primarily used in the manufacture of acrylonitrile butadiene styrene (ABS) resins, high impact polystyrene (HIPS) and phenolic resins. Among brominated phenolic flame retardants, 2,4,6-tribromophenol (TBP) is of particular interest. In terms of production is considered high production volume (>1000 tons/year) in the European Union. It has been recognized as emerging flame retardant as compared to PBDEs, HBCD and TBBPA (Covaci et al., 2011; Pivnenko et al., 2017). The adverse effects of some of these compounds together with their tendency to bioaccumulate in the environment have raised concerns for some time. Different adverse effects including, thyroid disruption, reproductive, and neurodevelopmental toxicity have been reported (Covaci, Voorspoels, Ramos, Neels, & Blust, 2007; McGrath, Morrison, Ball, & Clarke, 2017; Someya et al., 2016; Vilaplana et al., 2008). It has been suggested that one of the main routes of human exposure to BFRs occurs through the diet (Driffield et al., 2008; Sj¨ odin, Patterson, & Bergman, 2003). Whereas the presence of BFRs in food is primarily attributed to environmental contamination, the contribution from food contact materials may need to be considered (Pivnenko et al., 2017). Several studies have related the presence of these chemicals in food contact articles with the use of recycled materials in their manufacture. Samsonek and Puype (2013) reported the presence of BFRs in polymeric black food contact articles, specifically thermo cups and kitchen utensils. The authors suggested the BFRs very likely originated with recycled plastic derived from waste electric and electronic equipment (WEEE). Kuang, Abou-Elwafa Abdallah, and Harrad (2018) investigated the occurrence of bromine (Br) and BFRs in new and used kitchen utensils from UK. They concluded that higher BFR concentrations were found in * Correspondence to: US FDA, 5001 Campus Drive, College Park, MD 20740, USA. ** Corresponding author. E-mail addresses: [email protected] (R. Paseiro-Cerrato), [email protected] (A.R.-B. de Quir´ os). Contents lists available at ScienceDirect Food Packaging and Shelf Life journal homepage: www.elsevier.com/locate/fpsl https://doi.org/10.1016/j.fpsl.2022.100883 Received 16 February 2022; Received in revised form 28 April 2022; Accepted 30 May 2022
Food Packaging and Shelf Life 33 (2022) 100883 2 older utensils compared to the new articles. The transference of BFRs into hot olive oil was also studied, and BFRs concentrations were found particularly in the first exposure. The migration of bromophenols from high-density polyethylene (HDPE) containers into milk has been also described elsewhere (Robertson, 2012). Recently, migration of phenolic BFRs into food simulants and food from contaminated food contact articles was also demonstrated (Paseiro-Cerrato, De Jager, & Begley, 2021). Determination of BFRs, generally comprises an extraction step followed by instrumental analysis. Depending on the matrix the sample preparation can include a clean-up procedure. Different extraction techniques such as soxhlet extraction, supercritical-fluid extraction, pressurized liquid extraction, ultrasonic-assisted extraction and microwave-assisted extraction have been widely applied. The analysis is generally performed by gas or liquid chromatography coupled to mass spectrometry. Comprehensive two-dimensional gas chromatography (GC ×GC) has proven to be a valuable tool for the separation of PBDE congeners. However, these methods are time-consuming and laborious in addition to other limitations such as thermal degradation of some BFRs (Covaci et al., 2007; Kemmlein, Herzke, & Law, 2009; Vilaplana et al., 2008). X-ray fluorescence (XRF) is an analytical technique that can be used to determine bromine content in polymers including food contact materials. Several authors have used bench top and handheld XRFs for the rapid screening of BFRs (Aldrian, Ledersteger, & Pomberger, 2015; Puype, Ackerman, & Samsonek, 2019; Sharkey, Abdallah, Drage, Harrad, & Berresheim, 2018; Turner & Filella, 2017). The main drawback of XRF is that it is not compound specific, and the identities of brominated substances cannot be performed by using this technique. Direct analysis in real time (DART) ionization coupled to high resolution mass spectrometry (HRMS) represent an excellent analytical tool to overcome this drawback and to perform rapid screening targeted analysis of BFRs. Several studies have demonstrated the capability of this technique to identify BFRs in food contact materials (FCM) in little time (Paseiro-Cerrato, DeJager, & Begley, 2019; Puype et al., 2019). Recently, Paseiro-Cerrato, Ackerman, de Jager, and Begley (2021), analyzed 77 food contact articles and obtained BFRs false-positive and negative incidences equal or below to 5 %. It was concluded that the obtained data could support the implementation of DART-HRMS as a regulatory screening tool for BFR determination in FCAs. The goal of this study was to refine the accuracy assessments of DART-HRMS and XRF as screening tools to identify BFRs in polymeric food contact articles (FCAs) and develop an alternate HPLC method (HPLC-APCI-MS/MS) for the simultaneous determination of 3 BFRs (TBP, TBBPA and BDE-209) in FCAs, food and food simulants. The performance evaluation of the techniques (DART-HRMS, XRF and HPLC-MS/MS) for BFR determination in FCM was conducted. Migration of the 3 BFRs from contaminated food contact articles into food and food simulants was studied. 2. Material and methods 2.1. Chemicals and analytical standards Analytical standards of 2,4,6-Tribromophenol (TBP) (purity ≥98 %) (CAS: 118-79-6), and 3,3′,5,5′-Tetrabromobisphenol-A (TBBPA) (purity ≥97 %) (CAS: 79-94-7) were provided by Sigma Aldrich (Steinheim, Germany). Decabromodiphenyl ether (1.2 mL ×50 μ g/mL in toluene, purity >98 % (BDE-209) (CAS: 1163-19-5) and the internal standard (IS) 13 C 12 3,3′,5,5′-Tetrabromobisphenol-A (1.2 mL ×50 μ g/mL in methanol purity ≥99 %), were from Wellington Laboratories (Ontario, Canada) (Techno Spec). Methanol (LC-MS grade), ethanol (absolute for analysis), and isopropanol (HPLC-grade) were purchased from Merck (Darmstadt, Germany). Toluene (Certified ACS) was purchased from Fisher Scientific (New Jersey, USA). Purified water (Type I) was obtained from an Autwomatic Plus purification system (Wasserlab, Navarra, Spain). Individual stock standard solutions of TBP and TBBPA were prepared in methanol at a concentration of 1000 μ g/mL. Working solutions were prepared by volumetric dilution. For BDE-209, the working solutions were prepared by diluting the standard with methanol immediately before use. All solutions were protected from light using amber glassware capped with PE lid and stored at 4 ◦C. Reference materials of polymers containing BFRs used in XRF analysis were obtained from LGC Standard USA (Abby Road, Manchester, NH 03103). 2.2. Sample collection Food contact articles were bought in retail outlets in Santiago de Compostela (Spain). Only black and repeat use food contact articles were selected for this study. A description of the samples is summarized in Table 1. In some of the FCAs, different parts were considered to be analyzed because it has been reported in the literature that in some food contact Table 1 Sample description and identification of the type of material by FTIR-ATR. Samples Food contact article Parts analyzed Polymer Country of purchase 1 Coffee filter PP Spain 2 Coffee filter PP Spain 3 Forks PS Spain 4 Spoons PS Spain 5 Bottle stopper PP Spain 6 Plates PS Spain 7 Strainer coating PET Spain 8 Bowl Melamineformaldehyde Spain 9 Bottle 9A bottle stopper PP Spain 9B piece of the inside of the bottle PP 10 Bottle PP Spain 11 Spice mill 11A cogwheel PS Spain 11B main body PS 11C central axis PP 12 Glass with a straw straw PP Spain 13 Oil dispenser 13A pourer PP Spain 13B plastic tube Styrene based polymers 14 Coffee maker 14A part of the filter PP Spain 14B part of the filter PP 15 Teapot PP Spain 16 Coffee maker lid PP Spain 17 Ice cube tray Styrene-butadiene copolymer Spain 18 Pepper mill PS Spain 19 Food container PP Spain 20 Sugar bowl with a spoon 20 A bowl Melamineformaldehyde Spain 20B spoon Melamineformaldehyde 21 Isothermic drinking beaker 21 A inner part PP Spain 21B lid Polydimethylsiloxane PP: Polypropylene. PS: Polystyrene. PET – Polyethylene terephthalate. A. Lestido-Cardama et al.
Food Packaging and Shelf Life 33 (2022) 100883 3 articles the contamination by BFRs can be different depending on the different polymer sub-parts (Paseiro-Cerrato, Ackerman et al., 2021; Samsonek & Puype, 2013). Known FCAs contaminated with BFRs were provided by Dr. Paseiro- Cerrato. Synthesized (virgin) polypropylene (PP) and acrylonitrile butadiene styrene (ABS) polymer pellets for food contact applications were kindly provided by the industry. The virgin FCMs tested negative for the targeted BFRs, which is consistent with obtained results in previous publications (Paseiro-Cerrato, Ackerman, et al., 2021; Paseiro-Cerrato, De Jager, et al., 2021). These polymers were used to evaluate the analytical method for BFRs determination by HPLC-MS/MS. 2.3. Extraction method and HPLC-MS/MS analysis 2.3.1. Extraction method The polymeric samples were cut into small pieces before extraction. Ultrasonic assisted extraction was used to extract the BFRs from the materials. Approximately 0.5 g of sample was weight into a glass vial, then 1 mL of a solution of methanol-isopropanol (50:50 v/v) was added the vial was closed and placed in an ultrasonic bath Branson 5510 (Danbury, CT, USA) for three hours at 65 ◦C. An aliquot of 380 µL was removed and 20 µL of the IS was added. The extract was then removed and filtered through 0.22 µm PTFE membrane filter (Advantec, Toyo Roshi Kaisha, Japan). Afterwards, the extracts were analyzed by HPLCMS/MS. The method was evaluated by using known BFR contaminated FCAs. 2.3.2. HPLC-MS/MS The HPLC-MS/MS system comprised an Accela autosampler, an Accela 1250 pump fitted with a degasser, and a column thermostatting system coupled to a triple quadrupole mass spectrometer TSQ Quantum Access max, controlled by Xcalibur 2.1.0 software (Thermo Fisher Scientific, San Jos´ e, CA, USA). The chromatographic separation was achieved using a KromaPhase C18 100 Å (150 mm ×3 mm internal diameter, 5 µm particle size) column from Scharlau (Barcelona, Spain). Mobile phases were MeOH and water. A gradient elution method was applied: for 2 min, the mobile phase was 80 % MeOH and 20 % water, and then the percentage of MeOH was gradually increased, reaching 90 % at minute 12, followed by another gradient to 100 % MeOH at minute 13, and finally this composition was held constant until minute 28. The gradient elution finishes in minute 16 for ESI mode. The column was kept at 40 ◦C. The flow rate remained constant at 0.4 mL/min, and the injection volume was 20 µL. The mass spectrometer was operated in negative mode using both sources: atmospheric pressure chemical ionisation (APCI) and electrospray ionization (ESI). The operating conditions were as follows: Nitrogen was used as the sheath gas at a pressure of 35 psi, and as auxiliary gas (pressure 10 arbitrary units), argon was used as the collision gas at a pressure of 1.5 mTorr, the vaporizer temperature and capillary temperature were at 340 and 300 ◦C, respectively. When data were acquired in selected reaction monitoring (SRM) mode, two transitions of each compound were chosen for identification purposes and should match lower than 20 % with regard to the ratio of standards. The corresponding collision energy was optimized for maximum intensity. MS/MS conditions are given in Table 2. 2.3.3. Quantification Calibration curves were obtained by plotting the peak area ratio of each analyte to the internal standard (IS) versus the concentration of the corresponding analytes. Calibration curves were constructed based on five concentration levels of standard solutions. The concentration of the IS was 50 ng/mL. Each point of the calibration curve is the average of two peak area measurements. 2.4. Instrumental analysis 2.4.1. DART-HRMS The instrument method, sample preparation and data processing were similar to those described in previous publications (Paseir- o-Cerrato et al., 2019; Paseiro-Cerrato, Ackerman et al., 2021; Puype et al., 2019). Briefly, the instrument conditions were as follows: DART-SVP source (IonSense, Saugus, MA) tip was placed 2 cm from the GIST™ ceramic transfer tube (47 mm), which was ~ 1 mm from the MS entrance capillary and differentially pumped with a membrane pump (Vacuubrand MZ 2NT). The employed ionization gas was UPC (grade-5) helium. The capillary temperature was 300 ◦C and the heater temperature was set at 500 ◦C. The Q-Exactive™ HRMS (ThermoFisher Scientific, Bremen, Germany) was used in the negative mode. The resolution was 140.000 FWHM, S-lens RF level was 50, and the HRMS was operated in full scan range from 78 to 1180 m/z. Food contact articles samples were cut into small (~ 2–15 mm) pieces using cutters and were placed (using tweezers) ~ 2–10 mm from the DART source in line with the GIST transfer tube. The sample pieces were held in-line for approximately 5 s or until smoking or melting risked touching transfer ceramics. Cutters and tweezers used for sample treatment were previously cleaned with toluene. 2.4.2. XRF A Thermo Scientific ARL Quant’x EDXRF Analyzer controlled by an Acquisition manager Thermo electron (version 4.1 build 9), was used for FCAs XRF analysis. Instrument conditions were as follows: For Sb analysis, voltage was set at 50 kV, filter was Cu thick, high Zb, atmosphere was air, count rate was set at high and live time was 100 s. For Br analysis, voltage was 28 kV, filter was Pd thick, mid Zc, atmosphere was air, count rate was set at high and live time was 100 s. Coefficient correlation for the analysis was obtained by plotting peak area against concentration of reference materials and polymer blanks. Polymeric samples (FCAs and reference materials) were placed in XRF samples cups (Chemplex® Industries, Palm City, Florida, USA) and covered with Prolene® Thin-Film (Chemplex® Industries, Palm City, Florida, USA) prior performing the XRF analysis. 2.4.3. FTIR-ATR Infrared spectra were acquired using an ATR (attenuated total reflectance) – FTIR spectrometer (ATR-PRO-ONE, FTIR 4700, Jasco, Tokyo, Japan) equipped with a diamond optical crystal. ATR-FTIR spectrometer was controlled by the software Spectra Manager (version 2) in the region from 4000 to 650 cm −1 . The spectra identification was performed by using KnowItAll 17.4.135. B software to compare the sample spectra obtained with several commercial database related with polymers (IR Spectral Libraries of Polymers & Related Compounds from Bio-Rad Laboratories, Inc. Philadelphia, PA, USA). 2.5. Migration tests As all the samples included in the study were repeated use articles. Three consecutive exposures to the foodstuff or food simulants were Table 2 MS/MS conditions for the selected compounds with their retention times. BFR Retention time Source Parent ion Product ion Collision gas energy (V) TBP 5.20 APCI/ ESI 328.6 79.2 34 81.0 50 TBBPA 6.00 APCI/ ESI 542.6 418.6 39 446.6 34 TBBPA 13 C 6.10 APCI/ ESI 554.8 429.3 36 458.0 36 BDE-209 25.20 APCI 488.5 379.5 41 381.6 39 A. Lestido-Cardama et al.
Food Packaging and Shelf Life 33 (2022) 100883 4 carried out. Specific migration tests were performed with food simulants and food. The test type and testing conditions are listed in Table 3 (Beldi, Jakubowska, Robouch, & Hoekstra, 2019; Simoneau, 2009). 3. Results and discussion In this study the capability of DART-HRMS and XRF as a screening tool in the identification of BFRs in plastic materials intended for food contact was explored. The analysis revealed the presence of three BFRs, specifically, TBP, TBBPA and BDE-209 in the samples analyzed. To validate the results obtained by the screening techniques, an HPLC-MS/MS was developed for the simultaneous determination of the three BFRs. 3.1. DART-HRMS and XRF screening For the DART-HRMS we search for ions corresponding to BFRs previously analyzed in another study (Paseiro-Cerrato, Ackerman et al., 2021). To consider a sample positive by DART, the following specifications were required: Detection of at least two ions consistent with the accurate mass of the characteristic spectra of a targeted BFR, intensity in the detector ≥E4, appropriate time corresponding to the DART chronogram and a mass tolerance of ≤5 ppm. From the 21 analyzed samples, 6 tested positive in BFRs by DART (Table 4). Three BFRs were detected in the samples, TBP, TBBPA and BDE-209 (Fig. 1). These results are consistent with previously detected BFRs in contaminated FCAs (Paseiro-Cerrato et al., 2019; Paseiro-Cerrato, Ackerman et al., 2021; Puype et al., 2019). We also analyzed the FCA samples by XRF. The bromine (Br) and antimony (Sb) content were calculated by plotting the signal response of the reference’s materials against concentration. Five samples were Br positive by XRF. Four of them (samples 5, 11, 14 and 21) were in good agreement with DART results. Because it has been proposed that Sb at or near 1:3 ratio with Br is suggestive for the presence of WEEE contamination, we also estimated the Sb concentrations. Four samples contained clearly detected Sb concentrations. Because the reference materials may not match the polymer composition, sample distance, thickness, size, distribution in the sample collector to the FCA, the presented results can be only considerer semi-quantitative. A good example that would support this statement are XRF results obtained for samples 5 and 21. These two samples have lower Br and Sb concentrations than samples 11 and 14. While the ratio Sb/Br for samples 11 and 14 is close to 1:3, in the other two samples the ratio is close to 1:1. The main difference between samples 5 and 21 is the polymer size, thickness and distribution in sample collector, which could have impacted the Br and Sb LODs/LOQs, thus, giving a ratio 1:1. Regardless, the detection of Br and Sb would support the contamination coming from WEEE. When comparing DART with HPLC-MS/MS as a confirmatory technique, 100 % of samples detected by HPLC-MS were also detected by DART. Sample 9 tested positive by DART-HRMS but tested negative by HPLC-MS/MS (Table 4) and therefore, this would be considered a DART false positive. Based on these results, DART-HRMS false positive rates and incidences were 6 % and 5 % respectively. The results are consistent with results presented by Paseiro-Cerrato, Ackerman et al. (2021). However, in this study, we had no false negatives (0 %). The data obtained in this study, continues to support the use of DART as an appropriate and reliable rapid screening technique to detect BFRs in contaminated FCAs (Paseiro-Cerrato, Ackerman et al., 2021). Similarly, by XRF, false positive rates of 6 % and false positive incidences of 5 % were obtained. In this case, because XRF is a universal Br detector, it is possible that sample 16 could contain a brominated substance other than the targeted BFRs. XRF false negative rates and incidences were 20 % and 5 % respectively (1/5, 1/21) when compared with HPLC-MS results for BFR confirmation. In these samples, it is likely that the that XRF was not sensitive enough to detect the low concentrations of BFRs present in the sample 17. When comparing XRF with HPLC-MS/MS as a confirmatory technique, 4 out of 5 (80 %) of samples detected by HPLC-MS/MS were also detected by XRF. These results suggest that the use of both screening techniques (DART-HRMS and XRF) combined could be used as complimentary support in the identification of contaminated samples. 3.2. HPLC-MS/MS method optimization BFRs have been traditionally analyzed by GC-MS, nevertheless degradation problems associated with polybrominated diphenyl ethers have been reported (Stapleton, 2006). Moreover, phenol-based flame retardants such as TBBPA may require a derivatization step before the chromatographic analysis which usually is a laborious and time-consuming process (Kemmlein et al., 2009; Schlummer et al., 2005; Tollb¨ ack, Crescenzi, & Dyremark, 2006; Vilaplana et al., 2008). Liquid chromatography appears as a good option to overcome these drawbacks. Taking into account all these considerations, an HPLC-MS/MS method that allows the determination of the three BFRs in a single-run was developed. Firstly, several experiments were carried out to select the most appropriate ionization mode. For that purpose, a direct infusion of standard solutions of each analyte in methanol was performed. ESI was found to be more sensitive than APCI for TBP and TBBPA, however BDE-209 cannot be ionized by ESI, hence APCI was chosen as a compromise solution that allows the simultaneous determination of the three flame retardants. Once the fragmentation pattern was obtained, the collision energy was optimized for each compound to achieve the highest sensitivity. The main ion for TBBPA was m/z 542.6 corresponding to the deprotonated molecule [M-H] - and m/z 554.8 for the 13 C-labeled TBBPA. BDE-209 showed the most abundant ion at m/z 488.5 and TBP at m/z 328.6 (Table 2). Our results are consistent with Table 3 Migration test conditions and migration of BFRs from the food contact articles into food and food simulants. APCI ESI Sample Food contact article Food/Food simulant Migration test Time-temperature conditions Migration assay TBP ( μ g/kg) TBBPA ( μ g/kg) BDE-209 ( μ g/kg) TBP ( μ g/kg) TBBPA ( μ g/kg) 5 Bottle stopper 95 % Ethanol (v/ v) Total immersion 10 days 40 ◦C Migration 1 <LOD <LOD 20 <LOD <LOD Migration 2 <LOD <LOD <LOD <LOD <LOD Migration 3 <LOD <LOD <LOD <LOD <LOD 11 Spice mill Pepper Article fill 10 days 50 ◦C Migration 1 <LOD <LOD <LOD <LOD <LOD Migration 2 <LOD <LOD <LOD <LOD <LOD Migration 3 <LOD <LOD <LOD <LOD <LOD 14 Coffee maker 20 % Ethanol (v/ v) Article fill with simulant boiling Fill with the simulant boiling and leave 30 min between the heating and keeping hot Migration 1 <LOD <LOD <LOD <LOD 7 Migration 2 <LOD <LOD <LOD 8 6 Migration 3 60 <LOD <LOD 53 6 21 Isothermic drinking beaker 95 % Ethanol (v/ v) Article fill with simulant boiling Fill with the simulant boiling and keep container closed for 24 h Migration 1 <LOD <LOD 90 70 10 Migration 2 <LOD <LOD 40 50 <LOD Migration 3 <LOD <LOD 30 5 <LOD A. Lestido-Cardama et al.
Food Packaging and Shelf Life 33 (2022) 100883 5 Table 4 BFRs concentrations in the samples tested. *XRF samples can be only considered as semi-quantitative results. X =Identified by DART-HRMS. NA – Not analyzed. ND – Not detected. a =Samples 14A and 14B were analyzed together by triplicate. b =Average of two measurements. BFRs APCI ( μ g/kg) ESI ( μ g/kg) DART-HRMS XRF (ppm*) Samples TBP TBBPA BDE-209 TBP TBBPA TBP TBBPA BDE-209 Br/Sb 1 <LOD <LOD <LOD ND ND ND ND 2 <LOD <LOD <LOD ND ND ND ND 3 <LOD <LOD <LOD ND ND ND ND 4 <LOD <LOD <LOD ND ND ND ND 5 < LOD < LOD 410 ND ND X 8/9 6 <LOD <LOD <LOD ND ND ND ND 7 <LOD <LOD <LOD ND ND ND ND 8 <LOD <LOD <LOD ND ND ND ND 9A <LOD <LOD <LOD ND ND ND ND 9B <LOD <LOD <LOD <LOD <LOD X ND ND ND 10 <LOD <LOD <LOD ND ND ND ND 11A < LOD < LOD < LOD < LOD < LOD ND ND ND NA 11B 260 2180 1220 X X ND 52/19 11C < LOD < LOD < LOD ND ND ND NA 12 <LOD <LOD <LOD ND ND ND ND 13A <LOD <LOD <LOD ND ND ND ND 13B <LOD <LOD <LOD ND ND ND NA 14A <LOQ 70 7370 40 70 X X X 291 ± 2/128 ± 6 a 14B 150 1070 9340 X X X 15 <LOD <LOD <LOD ND ND ND ND 16 < LOD < LOD < LOD ND ND ND 1/ND 17 < LOD < LOD < LOD 10 < LOD X ND ND ND 18 <LOD <LOD <LOD ND ND ND ND 19 <LOD <LOD <LOD ND ND ND ND 20A <LOD <LOD <LOD ND ND ND NA 20B <LOD <LOD <LOD ND ND ND ND 21A 140 240 230 X X ND 2/3 b NA 21B < LOD < LOD < LOD 40 60 X ND ND Fig. 1. Example of a BFR spectra obtained by DART-HRMS. A) BDE-209 spectra in Sample 14. B) BDE-209 in standard solution. In both spectra, exact masses correspond to the adduct [BDE 209-C 6 Br 5 ] - . A. Lestido-Cardama et al.
Food Packaging and Shelf Life 33 (2022) 100883 6 those reported by other authors (Chi, Liu, Yua, Xie, & Jiang, 2017; Malysheva et al., 2018; Schlummer et al., 2005; Tollb¨ ack et al., 2006). The chromatographic conditions were adjusted in order to achieve an appropriate separation in a suitable analysis time. Thus, the mobile phase composition, elution mode and the injection volume were optimized. Initially, an isocratic elution mode with a mobile phase of 100 % methanol was assayed. However, under these conditions TBP and TBBPA were not properly separated. Next, a gradient consisting of methanol and water was used, the gradient program was varied until a complete separation was attained. Several injection volumes (10, 20, 30 and 40 µL) were tested to obtain higher sensitivity; 30 and 40 µL resulting in poor peak shape for TBBPA, therefore 20 µL was selected for further analysis. 3.3. Analytical performance The instrumental method was validated in terms of linearity, limits of detection and quantification, recovery and intermediate precision. The linearity of the optimized method was tested by using a series of BFRs standard solutions with known concentrations. Calibration curves were constructed using five concentration levels and they were fitted to a linear equation. The parameters of linearity are presented in Table 5. Appropriate coefficients of determination (≥0.994) were obtained for all compounds. The detection and quantification limits (LOD, LOQ) (defined as a signal three and ten times the high of the noise level, respectively) were calculated in accordance with the Analytical Chemical Subcommittee guidelines (American Chemical Society (ACS), 1980). The LODs of the target analytes ranged between 0.01 μ g/mL and 0.02 μ g/mL when APCI (-) MS/MS was used. TBP and TBBPA had higher sensitivity with ESI (-) MS/MS detection (0.001 μ g/mL). The values obtained were similar to those described by Vilaplana et al. (2008) for TBBPA (0.025 μ g/mL) and BDE-209 (0.011 μ g/mL) using HPLC-APCI-MS/MS and slightly lower to those reported by McGrath, Morrison, Ball, and Clarke (2016) and by Pivnenko et al. (2017) for BDE-209 (140 ng/mL) and for TBBPA (5 ng/g) using GC-(EI)-MS/MS and HPLC-ESI-MS/MS, respectively. The recovery of the method was assessed by spiking two samples, a plastic material (sample 4) and a food sample (pepper) with known amounts of the analytes at three concentration levels, 0.1, 0.15 and 0.2 μ g/g. Spiked samples were prepared by adding known concentrations of BFRs standards and allowed to infuse into the samples (15 min). The spiked samples were extracted as described above. Adequate recoveries (80–120 %) were achieved for all compounds studied (Table 5). It is important to note that, while these results show an acceptable recovery on the external layer of the spiked polymer (sample 4), different factors such as polymer and BFRs properties, has prevented other authors to claim quantitative BFRs results in polymers (Paseiro-Cerrato, Ackerman, et al., 2021; Paseiro-Cerrato, De Jager, et al., 2021; Samsonek & Puype, 2013). To obtain fully quantitative BFR data in polymers, extraction methods should be validated using homogenous polymeric reference materials with known concentrations of the same BFRs. The intermediate precision was calculated as the R.S.D. % from the analysis of spiked samples at three concentration levels (0.1, 0.15 and 0.2 μ g/g) in three different days (n =6). The method exhibited good repeatability, the RSD intermediate precision was below 20 % (European Commission (EC) guidelines) in all cases, for BDE-209 a value of 19.8 % was obtained this could be attributed to the degradation process associated to this compound, as it has been already reported by several authors (Covaci, Voorspoels, & de Boer, 2003; de Boer & Wells, 2006; G´ omara, Herrero, & Gonz´ alez, 2007; Nacher-Mestre, Serrano, Hernandez, Benedito-Palos, & Perez-Sanchez, 2010). None of the target analytes were detected in the procedural blanks. 3.4. Concentrations of BFRs in samples Infrared spectroscopy (FTIR) was used to identify the polymers of the samples investigated in this study. Out of all materials examined, polypropylene and polystyrene were the most common polymers identified. As it has been well documented in the literature, these materials are susceptible to be contaminated by BFRs (Martinho, Pires, Saraiva, & Ribeiro, 2012; Pivnenko et al., 2017; Puype, Samsonek, Knoop, Egelkraut-Holtus, & Ortlieb, 2015). These contaminants can be found in plastic food contact articles derived from the recycling process of plastics from the waste electrical and electronic equipment (WEEE) (Kuang et al., 2018; Samsonek & Puype, 2013). In terms of extraction method, ultrasonic extraction has proven to be a useful approach to extract BFRs from polymeric materials when low levels are expected (Kemmlein et al., 2009; P¨ ohlein, Segura Llopis, Wolf, & van Eldik, 2005). Moreover, this procedure saves solvent compared to the conventional and commonly used soxhlet extraction (Vilaplana et al., 2008). A mixture of methanol and isopropanol was chosen as a suitable extraction solvent for the target BFRs due to their different polarity (Riess & van Eldik, 1998). Regarding the solvent extraction volume, as is generally performed the solvent volume was two-fold the weight of the sample (Samsonek & Puype, 2013). The concentrations of BFRs in the polymeric food contact articles analyzed in this study ranged from <LOD and 260 μ g/kg; <LOD and 2180 μ g/kg and <LOD and 9340 μ g/kg for TBP, TBBPA and BDE-209, respectively (Table 4). The values obtained were similar than those reported by Pivnenko et al. (2017) for TBP (<LOD-680 ng/g) and TBBPA (<LOD-4400 ng/g) in household waste plastics; and somewhat lower than the values of <2.6–140000 ng/g BDE-209 determined by Kuang et al. (2018) in kitchen utensils. In any case, the concentrations found were not sufficient to impart flame retardancy which suggests that they were unintentionally added, and probably they come from recycled materials either from recycled intentionally flame retarded articles or result from degradation of high molecular weight BFRs (Kajiwara et al., 2011; Kuang et al., 2018; Table 5 Parameters of linearity and limits of detection (LOD) and quantification (LOQ) and recoveries of the target BFRs, and intermediate precision of the method. BFRs recoveries, % (BFRs repeatabilities, n =6, R.S.D. %) Sample 4 Pepper Analyte Linear range ( μ g/ mL) Equation R 2 LOD ( μ g/ mL) LOQ ( μ g/ mL) 0.1 μ g/g 0.15 μ g/g 0.2 μ g/g 0.1 μ g/g 0.15 μ g/g 0.2 μ g/g APCI TBP 0.05–0.1 y =0.5688x −0.4885 0.994 0.02 0.05 103 (19.3) 115 (7.2) 83 (17.8) 109 (14.1) 120 (15.5) 114 (5.2) TBBPA 0.05–0.1 y =0.4459x −0.3226 0.999 0.02 0.05 102 (6.0) 95 (18.2) 88 (16.8) 80 (13.8) 82 (13.8) 89 (17.5) BDE- 209 0.02–0.1 y =0.8939x −0.3612 0.996 0.01 0.02 100 (18.9) 100 (19.8) 105 (17.2) 87 (12.9) 100 (18.3) 105 (17.3) ESI TBP 0.005–0.1 y =0.007x −0.029 0.996 0.001 0.005 TBBPA 0.005–0.1 y =0.0055x −0.0382 0.994 0.001 0.005 A. Lestido-Cardama et al.
Food Packaging and Shelf Life 33 (2022) 100883 7 Pivnenko et al., 2017; Puype et al., 2015). Puype et al. (2015) also detected low concentrations of Br, too low to provide flame retardancy, in black polymeric food-contact articles sold on the European market. On the other hand, most of the positive samples contained all the three target analytes. The use of different types of BFRs in a single article is not a common flame retardant formulation, indicating that they possibly come from polymer mixtures from different sources (Pivnenko et al., 2017; Puype et al., 2015, 2017). Blanks of the polymeric food grade materials (PP and ABS) used as in-lab positive controls were also analyzed and none of the target analytes were detected. When higher sensitivity was needed, samples were also analyzed using ESI (-). 3.5. Migration assays The potential of BFRs to migrate into food and food simulants was evaluated by performing migration tests under repeated-use conditions. As far as we know very scarce information about BFRs migration data Fig. 2. (a) TIC and SRM chromatogram of a migration extract corresponding to sample 11 showing the presence of lower brominated congeners of BDE-209; and (b) TIC and SRM chromatogram of a standard of BDE-209.,. A. Lestido-Cardama et al.
Food Packaging and Shelf Life 33 (2022) 100883 8 from food contact materials are available in the scientific literature (Kuang et al., 2018; Paseiro-Cerrato, De Jager, et al., 2021). In this study, four samples comprising, a bottle stopper, a spice mill, a coffee maker and an isothermic drinking beaker were selected to carry out the assays. An overview of the results is presented in Table 3. The sample 5 (a bottle stopper) exhibited only migration in the first test, the concentration of BDE-209 detected in the food simulant was 20 μ g/kg. With the sample 11 (a spice mill) the migration test was performed using pepper, in this case the material did not release detectable levels of BFRs, however it is noteworthy that a peak that could correspond to a lower brominated congener of BDE-209 was detected in the three migrations tests (Fig. 2). As indicated in previous studies BDE-209, is particularly sensitive in alcoholic solutions and to UV and sunlight as well and as a result can be debrominated to lower congeners (Vilaplana et al., 2008). Regarding the sample 14 (a coffee maker) release of TBP and TBBPA were also observed in the second and third test. However, BDE-209 was not detected in the three migration tests, which may be explained because of the low solubility of the migrant (Experimental log P =9.3 (source: Chemspider)) in the food simulant 20 % ethanol. In comparison, TBP and TBBPA are much more polar (Experimental log P =3, & 5.7 respectively (source: Chemspider)). On the other hand, TBP concentration increased in the second and third migration, this may be due to deterioration of the material under the migration conditions, and under repeated conditions of use, the release of the substance increased. In the case of sample 21 (an isothermic drinking beaker) yielded detectable concentrations of BDE-209 and TBP in the third migration test. None of the detected BFRs in the analyzed food simulants are listed in the positive list of the European Union (Commission Regulation (EU) No 10/2011). Accordingly, particular attention should be paid to the safety of these BFR migrating food contact articles. 4. Conclusions DART-HRMS has demonstrated to be a powerful analytical tool for the rapid identification of BFRs in polymeric food contact materials. With this approach minimal sample treatment is required and the analysis is completed in little time (minutes). Under the conditions of this study, the rates and incidences of false positives and negatives were ≤6 %. These results continue to support the use of DART as a rapid screening technique for regulatory purposes. Additionally, the use of XRF in conjunction with DART gives additional confidence in the rapid detection of samples contaminated with BFRs. An HPLC-MS/MS method was developed using atmospheric pressure chemical ionization (APCI) source for the quantification of the targeted BFRs. The validation parameters including instrumental linearity, LODs, LOQs, and method recovery and intermediate precision were satisfactory. Migration tests were carried out with food and food simulants. To the best our knowledge, this represents the 3rd report quantifying the migration of BFRs from food contact materials. Three of the four FCAs tested released detectable amounts of BFRs. Since these substances are not included in the positive list these FCAs are likely violative. The quality of recycled materials in the manufacture of food contact materials should be monitored. CRediT authorship contribution statement A. Lestido-Cardama: Investigation, Formal analysis, Validation, Writing – original draft. R. Paseiro-Cerrato: Conceptualization, Methodology, Investigation, Validation, Writing – original draft, Writing – review & editing, Supervision, Project administration. L.K. Ackerman: Conceptualization, Methodology, Writing – review & editing, Supervision. R. Send´ on: Writing – review & editing, Supervision. A. Rodríguez-Bernaldo de Quir´ os: Methodology, Writing – original draft, Supervision, Project administration. References Aldrian, A., Ledersteger, A., & Pomberger, R. (2015). Monitoring of WEEE plastics in regards to brominated flame retardants using handheld XRF. Waste Management, 36, 297–304. https://doi.org/10.1016/j.wasman.2014.10.025 American Chemical Society (ACS). (1980). Subcommittee of environmental analytical chemistry. Analytical Chemistry, 52, 2242–2280. 〈https://pubs.acs.org/doi/pdf/10 .1021/ac50064a004〉. Beldi, G., Jakubowska, N., Robouch, P., & Hoekstra, E. (2019). Testing conditions for kitchenware articles in contact with foodstuffs. Part 1: Plastics. The EURL-FCM Harmonised Approach Series, Article JRC116750. Chi, X., Liu, J., Yua, M., Xie, Z., & Jiang, G. (2017). Analysis of bromophenols in various aqueous samples using solid phase extraction followed by HPLC-MS/MS. Talanta, 164, 57–63. https://doi.org/10.1016/j.talanta.2016.11.010 Commission Regulation (EU) No 10/2011. (2011). Commission Regulation (EU) No 10/ 2011of 14 January 2011 on plastic materials and articles intended to come into contact with food. Official Journal of the European Union, L12, 1–89. Covaci, A., Voorspoels, S., & de Boer, J. (2003). Determination of brominated flame retardants, with emphasis on polybrominated diphenyl ethers (PBDEs) in environmental and human samples—A review. Environment International, 29, 735–756. https://doi.org/10.1016/S0160-4120(03)00114-4 Covaci, A., Voorspoels, S., Ramos, L., Neels, H., & Blust, R. (2007). Recent developments in the analysis of brominated flame retardants and brominated natural compounds. Journal of Chromatography A, 1153, 145–171. https://doi.org/10.1016/j. chroma.2006.11.060 Covaci, A., Harrad, S., Abdallah, M. A. E., Ali, N., Law, R. J., Herzke, D., & de Wit, C. A. (2011). Novel brominated flame retardants: A review of their analysis, environmental fate and behavior. Environment International, 37, 532–556. https:// doi.org/10.1016/j.envint.2010.11.007 de Boer, J., & Wells, D. E. (2006). Pitfalls in the analysis of brominated flame retardants in environmental, human and food samples – Including results of three international interlaboratory studies. Trends in Analytical Chemistry, 25(4), 364–372. https://doi. org/10.1016/j.trac.2006.01.008 Driffield, M., Harmer, N., Bradley, E., Fernandes, A. R., Rose, M., Mortimer, D., & Dicks, P. (2008). Determination of brominated flame retardants in food by LC–MS/ MS: Diastereoisomer-specific hexabromocyclododecane and tetrabromobisphenol A. Food Additives and Contaminants, 25(7), 895–903. https://doi.org/10.1080/ 02652030701882999 European Commission Directorate General for Health and Food Safety. SANTE/11813/ 2017. (2017). Analytical quality control and method validation procedures for pesticide residues analysis in food and feed. European Food Safety Authority. (2011). Scientific opinion on tetrabromobisphenol A (TBBPA) and its derivatives in food. EFSA panel on contaminants in the food chain (CONTAM). EFSA Journal, 9(12), 1–67 (2477). European Food Safety Authority. (2012). Scientific opinion on brominated flame retardants (BFRs) in food: Brominated phenols and their derivatives. EFSA panel on contaminants in the food chain (CONTAM). EFSA Journal, 10(4), 1–42 (2634) 〈http ://www.efsa.europa.eu/en/efsajournal/pub/2634〉. G´ omara, B., Herrero, L., & Gonz´ alez, M. J. (2007). Feasibility of electron impact and electron capture negative ionisation mass spectrometry for the trace determination of tri- to deca-brominated diphenyl ethers in human samples. Analytica Chimica Acta, 597, 121–128. https://doi.org/10.1016/j.aca.2007.06.037 Hyoe¨tylae¨inen, T., & Hartonen, K. (2002). Determination of brominated flame retardants in environmental samples. Trends in Analytical Chemistry, 21(1), 13–29. Kajiwara, N., Noma, Y., & Takigami, H. (2011). Brominated and organophosphate flame retardants in selected consumer products on the Japanese market in 2008. Journal of Hazardous Materials, 192, 1250–1259. https://doi.org/10.1016/j. jhazmat.2011.06.043 Kemmlein, S., Herzke, D., & Law, R. J. (2009). Brominated flame retardants in the European chemicals policy of REACH—Regulation and determination in materials. Journal of Chromatography A, 1216, 320–333. https://doi.org/10.1016/j. chroma.2008.05.085 Kuang, J., Abou-Elwafa Abdallah, M., & Harrad, S. (2018). Brominated flame retardants in black plastic kitchen utensils: Concentrations and human exposure implications. Science of the Total Environment, 610–611, 1138–1146. https://doi.org/10.1016/j. scitotenv.2017.08.173 Malysheva, S. V., Goscinny, S., Malarvannan, G., Poma, G., Andjelkovic, M., Voorspoels, S., … Van Loco, J. (2018). Development and validation of a quantitative UHPLC-MS/MS method for selected brominated flame retardants in food. Food Additives & Contaminants: Part A, 35(2), 292–304. https://doi.org/10.1080/ 19440049.2017.1393110 Martinho, G., Pires, A., Saraiva, L., & Ribeiro, R. (2012). Composition of plastics from waste electrical and electronic equipment (WEEE) by direct sampling. Waste Management, 32, 1213–1217. https://doi.org/10.1016/j.wasman.2012.02.010 McGrath, T. J., Morrison, P. D., Ball, S., & Clarke, B. O. (2016). Selective pressurized liquid extraction of replacement and legacy brominated flame retardants from soil. Journal of Chromatography A, 1458, 118–125. https://doi.org/10.1016/j. chroma.2016.06.021 McGrath, T. J., Morrison, P. D., Ball, A. S., & Clarke, B. O. (2017). Detection of novel brominated flame retardants (NBFRs) in the urban soils of Melbourne, Australia. Emerging Contaminants, 3, 23–31. https://doi.org/10.1016/j.emcon.2017.01.002 Nacher-Mestre, J., Serrano, R., Hernandez, F., Benedito-Palos, L., & Perez-Sanchez, J. (2010). Gas chromatography–mass spectrometric determination of polybrominated A. Lestido-Cardama et al.
Food Packaging and Shelf Life 33 (2022) 100883 9 diphenyl ethers in complex fatty matrices from aquaculture activities. Analytica Chimica Acta, 664, 190–198. https://doi.org/10.1016/j.aca.2010.02.015 Paseiro-Cerrato, R., DeJager, L., & Begley, T. H. (2019). Food contact materials: Characterization of migrants. In M. Granvog, & S. MacMahon (Eds.), Food-borne toxicants: Formation, analysis, and toxicology (pp. 123–133). American Chemical Society. Paseiro-Cerrato, R., Ackerman, L., de Jager, L., & Begley, T. (2021). Brominated flame retardants (BFRs) in contaminated food contact articles: Identification using DARTHRMS and GC-MS. Food Additives & Contaminants: Part A, 38, 350–359. https://doi. org/10.1080/19440049.2020.1853250 Paseiro-Cerrato, R., De Jager, L., & Begley, T. H. (2021). Migration of phenolic brominated flame retardants from contaminated food contact articles into food simulants and foods. Food Additives & Contaminants: Part A, 38, 464–475. https:// doi.org/10.1080/19440049.2020.1871082 Pivnenko, K., Granby, K., Eriksson, E., & Astrup, T. F. (2017). Recycling of plastic waste: Screening for brominated flame retardants (BFRs). Waste Management, 69, 101–109. https://doi.org/10.1016/j.wasman.2017.08.038 P¨ ohlein, M., Segura Llopis, A., Wolf, M., & van Eldik, R. (2005). Rapid identification of RoHS-relevant flame retardants from polymer housings by ultrasonic extraction and RP-HPLC/UV. Journal of Chromatography A, 1066, 111–117. https://doi.org/ 10.1016/j.chroma.2005.01.036 Puype, F., Samsonek, J., Knoop, J., Egelkraut-Holtus, M., & Ortlieb, M. (2015). Evidence of waste electrical and electronic equipment (WEEE) relevant substances in polymeric food-contact articles sold on the European market. Food Additives & Contaminants: Part A, 32(3), 410–426. https://doi.org/10.1080/ 19440049.2015.1009499 Puype, F., Samsonek, J., Vilímkov´ a, V., Kopeˇ ckov´ a, S., Ratiborsk´ a, A., Knoop, J., … Oppermann, U. (2017). Towards a generic procedure for the detection of relevant contaminants from waste electric and electronic equipment (WEEE) in plastic foodcontact materials: A review and selection of key parameters. Food Additives & Contaminants: Part A, 34(10), 1767–1783. https://doi.org/10.1080/ 19440049.2017.1332430 Puype, F., Ackerman, L. K., & Samsonek, J. (2019). Evaluation of direct analysis in real time – High resolution mass spectrometry (DART-HRMS) for WEEE specific substance determination in polymeric samples. Chemosphere, 232, 481–488. https:// doi.org/10.1016/j.chemosphere.2019.05.166 Riess, M., & van Eldik, R. (1998). Identification of brominated flame retardants in polymeric materials by reversed-phase liquid chromatography with ultraviolet detection. Journal of Chromatography A, 827, 65–71. Robertson, G. L. (2012). Food packaging: Principles and practice (3rd ed.). Florida, USA: CRC Press. Samsonek, J., & Puype, F. (2013). Occurrence of brominated flame retardants in black thermo cups and selected kitchen utensils purchased on the European market. Food Additives & Contaminants: Part A, 30(11), 1976–1986. https://doi.org/10.1080/ 19440049.2013.829246 Schlummer, M., Brandl, F., M¨ aurer, A., & van Eldik, R. (2005). Analysis of flame retardant additives in polymer fractions of waste of electric and electronic equipment (WEEE) by means of HPLC–UV/MS and GPC–HPLC–UV. Journal of Chromatography A, 1064, 39–51. https://doi.org/10.1016/j.chroma.2004.12.016 Sharkey, M., Abdallah, M. A. E., Drage, D. S., Harrad, S., & Berresheim, H. (2018). Portable X-ray fluorescence for the detection of POP-BFRs in waste plastics. Science of the Total Environment, 639, 49–57. https://doi.org/10.1016/j. scitotenv.2018.05.132 Simoneau, C. (2009). Guidelines on testing conditions for articles in contact with foodstuffs. (with a focus on kitchenware). A CRL-NRL-FCM publication 1st edition. EUR 23814 EN 2009. Sj¨ odin, A., Patterson, D. G., Jr., & Bergman, A. (2003). A review on human exposure to brominated flame retardants—Particularly polybrominated diphenyl ethers. Environment International, 29, 829–839. https://doi.org/10.1016/S0160-4120(03) 00108-9 Someya, M., Suzuki, G., Ionas, A. C., Tue, N. M., Xu, F., Matsukami, H., … Takigami, H. (2016). Occurrence of emerging flame retardants from e-waste recycling activities in the northern part of Vietnam. Emerging Contaminants, 2, 58–65. https://doi.org/ 10.1016/j.emcon.2015.10.002 Stapleton, H. M. (2006). Instrumental methods and challenges in quantifying polybrominated diphenyl ethers in environmental extracts: A review. Analytical and Bioanalytical Chemistry, 386, 807–817. https://doi.org/10.1007/s00216-006-0400-y Tollb¨ ack, J., Crescenzi, C., & Dyremark, E. (2006). Determination of the flame retardant tetrabromobisphenol A in air samples by liquid chromatography-mass spectrometry. Journal of Chromatography A, 1104, 106–112. https://doi.org/10.1016/j. chroma.2005.11.067 Turner, A., & Filella, M. (2017). Bromine in plastic consumer products – Evidence for the widespread recycling of electronic waste. Science of the Total Environment, 601–602, 374–379. https://doi.org/10.1016/j.scitotenv.2017.05.173 Vilaplana, F., Karlsson, P., Ribes-Greus, A., Ivarsson, P., & Karlsson, S. (2008). Analysis of brominated flame retardants in styrenic polymers: Comparison of the extraction efficiency of ultrasonication, microwave-assisted extraction and pressurised liquid extraction. Journal of Chromatography A, 1196–1197, 139–146. https://doi.org/ 10.1016/j.chroma.2008.05.001 A. Lestido-Cardama et al.