scieee AI-readable full text Open interactive document viewer

Advanced systems for biological treatment of high nitrogen-loaded wastewate

Arrojo Arrojo, Belén

Full text

UNIVERSIDADE DE SANTIAGO DE COMPOSTELA Departamento de Ingeniería Química Advanced systems for biological treatment of high nitrogen-loaded wastewater Memoria presentada por Belén Arrojo Arrojo Para optar al grado de Doctor por la Universidad de Santiago de Compostela Santiago de Compostela, Octubre de 2006 UNIVERSIDADE DE SANTIAGO DE COMPOSTELA Departamento de Ingeniería Química Advanced systems for biological treatment of high nitrogen-loaded wastewater Memoria presentada por Belén Arrojo Arrojo Para optar al grado de Doctor por la Universidad de Santiago de Compostela Santiago de Compostela, Octubre de 2006 UNIVERSIDADE DE SANTIAGO DE COMPOSTELA Departamento de Ingeniería Química Ramón Méndez Pampín, Catedrático de Ingeniería Química y Anuska Mosquera Corral, Profesora Ayudante de Ingeniería Química de la Universidad de Santiago de Compostela, Informan: Que la memoria titulada “Advanced systems for biological treatment of high nitrogen-loaded wastewater”, que para optar al grado de Doctor de Ingeniería Química, Programa de Doctorado en Ingeniería Química y Ambiental, presenta Doña Belén Arrojo Arrojo, ha sido realizado bajo nuestra inmediata dirección en el Departamento de Ingeniería Química de la Universidad de Santiago de Compostela. Y para que así conste, firman el presente informe en Santiago de Compostela, el 30 de Octubre de 2006. Ramón Méndez Pampín Anuska Mosquera Corral Esta memoria fue presentada el día 16 de febrero de 2007 en el salón de actos de la Escuela Técnica Superior de Ingeniería (ETSE) de la USC ante el tribunal compuesto por: Dr. José Mario Díaz Fernández de la Universidad de Oviedo. Dra. Merle K.de Kreuk de la Universidad Técnica de Delf (Holanda). Dra. Elena Ficara del Politécnico de Milán (Italia). Dr. Julián Carrera Muyo de la Universidad Autónoma de Barcelona. Dr. José Luís Campos Gómez de la Universidad de Santiago de Compostela. Con la calificación de Sobresaliente Cum Laude y la mención de Doctorado Europeo. Agradecimientos Después de todos estos años de trabajo, que han dado lugar a la presentación de mi tesis doctoral, quisiera expresar en estas líneas mi agradecimiento a todas aquellas personas, sin cuya inestimable ayuda, apoyo, dirección y amistad, no hubiera sido posible la realización de la misma. En primer lugar, quiero agradecer a Juan M. Lema y Ramón Méndez Pampín por brindarme la oportunidad de trabajar en el grupo de Ingeniería Ambiental y Bioprocesos de la USC. A mis directores de tesis, Ramón Méndez y Anuska Mosquera por ofrecerme la posibilidad de realizar este trabajo bajo su dirección, por haber confiado en mí para la puesta en marcha de sistemas granulares, por su gran ayuda, su incondicional apoyo y su colaboración durante todos estos años. A Ramón Méndez, por haberme facilitado siempre una fuente de financiación que me permitió llevar a cabo la investigación de forma cómoda durante todos estos años. A José Luis Campos, quien ha colaborado de forma muy directa en este trabajo, por sus expertos consejos, sus opiniones, su colaboración prestada en numerosas ocasiones y por idear siempre una solución para resolver cualquier cosa. De nuevo, a José Luis y Anuska por la gran cantidad de horas dedicadas a dirigir, orientar, enfocar, corregir y discutir minuciosamente los resultados de esta tesis y de las diversas publicaciones. A Juan M. Garrido, por haberme enseñado a trabajar en este campo y abrirme el camino de entrada al grupo, por todo lo que de él aprendí y por haberme ofertado llevar a cabo la puesta en marcha de la planta del LIGAL, la cual ha sido una gran experiencia para mí. Quisiera también agradecer a todo el equipo (Juan Garrido, Francisco Omil, Ramón Méndez y todo el personal de la empresa) con los que he trabajado en el seguimiento de esta depuradora durante varios años. Esta experiencia ha sido muy enriquecedora tanto a nivel científico como humano y a la vez, fue el punto de partida de la tesis doctoral. Por ello, agradecer al citado equipo todo el esfuerzo, las numerosas ideas, la dedicación, la paciencia y la gran ayuda mostrada durante los momentos más difíciles. A la Xunta de Galicia, a la Fundación Caixa-Galicia y al Ministerio de Educación y Ciencia por la financiación de los diferentes proyectos y bolsas de investigación que me permitieron llevar a cabo esta tesis doctoral. Nuevamente al Ministerio, por la concesión de la Acción Integrada España-Italia para poder realizar una estancia en ese país. A la Universidad de Santiago, la cual me ha T-2 Table of contents Chapter 2. Materials and methods 2-1 2.1 Liquid phase 2-3 2.1.1 Chemical Oxygen Demand (COD) 2-3 2.1.2 Total Organic Carbon (TOC) 2-5 2.1.3 Volatile Fatty Acids (VFA) 2-6 2.1.4 Nitrogen 2-7 2.1.5 Inorganic anions 2-11 2.1.6 Other control parameters 2-12 2.2 Solid phase 2-13 2.2.1 Total and Suspended Solids 2-13 2.3 Biomass characterisation 2-14 2.3.1 Granules density 2-14 2.3.2 Average diameter of the granules 2-15 2.3.3 Electron Microscopy and Micro-analysis 2-16 2.3.4 Sludge Volumetric Index 2-16 2.3.5 Zone Settling Velocity 2-17 2.4 Microbiological determinations 2-19 2.4.1 Faecal coliforms and Escherichia Coli 2-19 2.4.2 Identification of bacteria populations by Fluorescence in Situ Hybridisation 2-22 2.5 References 2-27 Chapter 3. Aerobic granulation with industrial wastewater in sequencing batch reactors 3-1 3.1 Introduction 3-3 3.2 Objectives 3-5 3.3 Materials and methods 3-5 3.3.1 Experimental set-up 3-5 3.3.2 Inocula 3-7 3.3.3 Feeding media 3-7 3.3.4 Strategy of operation 3-9 3.3.5 Analytical methods 3-10 3.4 Results and discussion 3-12 3.4.1 Biomass granulation process 3-12 T-3 Table of contents 3.4.2 Carbon and nitrogen removal in the system 3-18 3.4.3 Solids concentration in the effluent 3-26 3.5 Conclusions 3-30 3.6 References 3-31 Chapter 4. Nitrifying granular sludge production in a SBR 4-1 4.1 Introduction 4-3 4.2 Objectives 4-5 4.3 Materials and methods 4-5 4.3.1 Experimental set-up 4-5 4.3.2 Inocula 4-6 4.3.3 Feeding media 4-6 4.3.4 Strategy of operation 4-7 4.3.5 Analytical methods 4-8 4.3.6 Calculations 4-8 4.4 Results and discussion 4-9 4.4.1 Nitrogen removal 4-9 4.4.2 Biomass evolution 4-18 4.4.3 Biomass examination 4-22 4.5 Conclusions 4-28 4.6 References 4-28 Chapter 5. Effects of the hydrodynamic conditions and feeding composition on the aerobic granulation in SBRs 5-1 5.1 Introduction 5-3 5.2 Objectives 5-6 5.3 Materials and methods 5-6 5.3.1 Experimental set-up 5-6 5.3.2 Inocula 5-8 5.3.3 Feeding media 5-8 5.3.4 Strategy of operation 5-9 5.3.5 Analytical methods 5-10 5.4 Results and discussion 5-11 T-4 Table of contents 5.4.1 Biomass granulation process 5-11 5.4.2 Carbon and nitrogen removal in the system 5-20 5.4.3 Effect of mechanical stirrer 5-27 5.5 Conclusions 5-28 5.6 References 5-29 Chapter 6. Effects of hydrodynamic conditions on the performance of Anammox granular SBRs 6-1 6.1 Introduction 6-3 6.2 Objectives 6-5 6.3 Materials and methods 6-6 6.3.1 Experimental set-up 6-6 6.3.2 Feeding media 6-9 6.3.3 Inoculum 6-6 6.3.4 Analytical methods 6-10 6.3.5 Specific Anammox activity assays 6-11 6.3.6 Operational conditions 6-12 6.3.7 Calculations 6-13 6.4 Results and discussion 6-16 6.4.1 Nitrogen removal efficiency 6-16 6.4.2 Biomass evolution 6-20 6.4.3 Anammox activity: comparison between hydrodynamic and mechanical stress 6-33 6.5 Conclusions 6-38 6.6 References 6-39 6.7 Nomenclature 6-45 Chapter 7. A membrane coupled to a SBR for water reuse and removal of coliform bacteria 7-1 7.1 Introduction 7-3 7.2 Objectives 7-7 7.3 Materials and methods 7-7 7.3.1 Experimental set-up 7-7 T-5 Table of contents 7.3.2 Feeding media 7-11 7.3.3 Strategy of operation 7-12 7.3.4 Analytical methods 7-13 7.3.5 Determination of critical and maximum flux 7-13 7.4 Results and discussion 7-14 7.4.1 Membrane coupled-SBR 7-14 7.4.2 Determination of critical flux and maximum flux 7-17 7.4.3 Two configurations 7-21 7.5 Conclusions 7-23 7.6 References 7-23 Conclusions C-1 Conclusiones C-5 Conclusións C-9 List of publications L-1 O-1 Objetivos y Resumen Las diversas legislaciones, cada vez más exigentes, están reduciendo cada vez más las concentraciones máximas permitidas de contaminantes en los efluentes, lo que está impulsando el desarrollo de sistemas más eficaces y compactos en los cuales se pueda llevar a cabo la eliminación conjunta de materia orgánica y/o nutrientes. Los nuevos sistemas de tratamiento biológico deben ocupar menos espacio, mejorar la retención y producción de lodos, y además deben presentar mejores propiedades para su posterior gestión, logrando así no sólo la mejora de la calidad de los efluentes generados sino también una reducción de costes. Como alternativa al proceso convencional de lodos activos se propone el empleo de reactores biológicos de lodo granular y sistemas de membranas. El objetivo es lograr una alta eliminación de carbono y nitrógeno en aguas residuales urbanas e industriales y generar, asimismo efluentes tratados aptos para su reutilización. Estos reactores pueden operar con cargas más elevadas (plantas más compactas) debido al desarrollo de una biomasa agregada en forma de gránulos, con buenas características de sedimentabilidad, lo que posibilita su fácil separación en el propio reactor, siendo posible sustituir los grandes y costosos decantadores secundarios por ejemplo por unidades de membrana externas mucho más pequeñas que permiten mejorar la calidad física, química y microbiológica del efluente y propiciar su reutilización. Por otro lado, la alta productividad de los microorganismos heterótrofos empleados en los sistemas convencionales de tratamiento de aguas trae consigo la O-2 Objetivos y Resumen generación de grandes cantidades de lodos, que suponen un importante aumento en los costes de operación, así como, un problema ambiental. El uso de gránulos en el tratamiento de aguas residuales puede contribuir a la reducción del residuo generado mediante dos posibles vías: 1) Reducción de la cantidad de lodos producidos: Se ha encontrado que la producción de lodos en sistemas granulares era un 30% menor que en sistemas de lodos activos. Este hecho, puede deberse a que los microorganismos que crecen formando gránulos, tienen una mayor proporción de exopolímeros en su composición para mantener su estructura. La producción de dichos compuestos implica la variación del metabolismo de los microorganismos, empleando más energía en este proceso en comparación con los floculantes. 2) Reducción del volumen de lodo: durante el tratamiento del lodo generado la mayor parte de los procesos aplicados se centran en la reducción de su volumen mediante la disminución de su contenido en agua. Dado que el mecanismo de selección de los microorganismos formadores de gránulos en los biorreactores granulares es la velocidad de decantación, dichos gránulos tienen estructuras más compactas y más densas que los flóculos lo que lleva directamente a un menor volumen de lodo. Por otra parte, se ha encontrado que durante la granulación las células aumentaban su hidrofobicidad del 50 al 80%, lo que puede favorecer los procesos de deshidratación del lodo. Los estudios que se han llevado a cabo hasta la fecha en el desarrollo de biorreactores granulares aerobios han permitido establecer la hipótesis de que la formación de lodos granulares es posible en sistemas operados en ciclos con cortos períodos de alimentación y de sedimentación. Otros factores que afectan a las características de los gránulos formados son: i) El tipo de efluente tratado, urbano o industrial; ii) Condiciones de estrés, es decir cuanto mayor es el estrés aplicado, menor es el tamaño de los gránulos formados y mayor su densidad mejorando así su sedimentación; iii) Cuanto más lentamente crece la biomasa al degradar un substrato, más densos y pequeños serán los gránulos obtenidos, siendo necesario evaluar el efecto de los sólidos presentes en el efluente tratado; iv) Concentración de oxígeno: bajas concentraciones de oxígeno mejoran la eficacia de eliminación de nitrógeno en los biorreactores O-3 Objetivos y Resumen granulares, pero en muchos casos impiden o ralentizan la formación de los gránulos; v) Geometría del reactor (relación altura/diámetro). En la presente tesis se estudian inicialmente el efecto de la composición del agua residual sobre la formación del gránulo, investigando posteriormente las condiciones hidrodinámicas más propicias para desarrollar los gránulos en condiciones aerobias. El desarrollo y aplicación de sistemas granulares se hace tanto en aguas con una alta relación C/N, a las que se aplica el proceso de nitrificación-desnitrificación, como en aguas con una baja relación C/N, a las que se aplica un proceso avanzado de oxidación anaerobia de amonio (Anammox). Además, se ensayan distintas condiciones de operación con el fin de maximizar la eficacia de eliminación de la materia orgánica y del nitrógeno, para cada tipo de agua residual a tratar, y tipo de lodo granular empleado. El lodo granular producido se cuantifica y caracteriza durante la operación de los reactores. Los sistemas granulares producen unos efluentes de buena calidad, en términos de contenido en materia orgánica y nitrógeno, pero con concentraciones de sólidos en suspensión que en ocasiones no se ajustarían a los requerimientos más estrictos (menores de 35 mg SS/L), lo que justifica la utilización de sistemas de filtración de membranas como tratamiento complementario. En los sistemas de membranas se evaluan las mejores condiciones de operación (tipo de membrana, ensuciamiento, protocolos de limpieza, etc.) así como la calidad fisico-química y microbiológica de los efluentes generados para evaluar la posible reutilización de los mismos para uso industrial, agrícola o de riego, tomando como referencia las normas nacionales, comunitarias e internacionales vigentes. En el Capítulo 1, se hace una revisión bibliográfica relacionada con la granulación en condiciones aerobias/anóxicas/anaerobias, que incluye la formación de los gránulos y su comportamiento, los procesos de eliminación biológica de nitrógeno (nitrificación, desnitrificación y Anammox), y la tecnología de membranas. En los últimos años, la investigación sobre los procesos de granulación ha sido muy amplia. Hasta la fecha, la mayoría de los gránulos obtenidos en O-4 Objetivos y Resumen condiciones aerobias se ha llevado a cabo en reactores discontinuos tipo SBR (Sequencing Batch Reactor). En estos sistemas SBR se obtienen gránulos con menos producción de lodos y mayores velocidades de conversión que en los sistemas convencionales de lodos activos. Altas concentraciones de biomasa se pueden obtener en estos sistemas debido a la compacta estructura de los gránulos aerobios. Además esta tecnología se basa en el uso de un reactor único (SBR), en el que se realizan todas las fases de operación: llenado, reacción, sedimentación y vaciado. Este hecho tiene la ventaja de que es necesario disponer de menos espacio y equipos para llevar a cabo el proceso. Diferentes parámetros afectan a la formación de gránulos aerobios/anóxicos/anaerobios en SBRs como pueden ser: productividades celulares de los diferentes microorganismos, fuerzas de estrés (que dependerán de la hidrodinámica del reactor), selección de la biomasa que se lleva a cabo a través del tiempo de decantación, tipo de sustrato, Demanda Química de Oxígeno (DQO), carga de nitrógeno y concentración de oxígeno. El proceso Anammox (ANaerobic AMMonium OXidation), se presenta en la actualidad como una alternativa eficaz para eliminar compuestos nitrogenados presentes en aguas residuales con alto contenido de nitrógeno, pero baja concentración de materia orgánica, en comparación con los procesos convencionales de nitrificación/desnitrificación. Recientemente, el número de trabajos enfocados al estudio del proceso Anammox se ha incrementado, sin embargo, pocos de ellos se han encaminado al estudio de los aspectos ingenieriles para llevar a cabo la implantación de dicho proceso a escala real. En la presente tesis se evalúan estos aspectos. En el Capítulo 2 se describen los métodos analíticos usados en el trabajo. Esto incluye, tanto los parámetros convencionales de caracterización de aguas residuales (materia orgánica, compuestos nitrogenados, pH, oxígeno disuelto, sólidos y compuestos de carbono), como la caracterización de la biomasa. En este último caso, la caracterización de la biomasa se llevó a cabo utilizando parámetros como: la densidad de los gránulos, el índice volumétrico de lodos y otras técnicas como pueden ser el análisis de imagen, observación con lupa y microscopio y finalmente la microscopía electrónica. La identificación de los O-5 Objetivos y Resumen diferentes tipos de poblaciones se realizó usando la técnica de FISH (Fluorescent In Situ Hybridisation). La técnica del FISH permite la detección selectiva de un microorganismo en particular presente en un lodo biológico conteniendo muchos otros microorganismos diferentes. Este método se basa en el uso de la secuencia específica de la subunidad 16S del ARN ribosomal (ARNr) perteneciente al microorganismo en cuestión. En esta técnica se usan cadenas de oligonucleótidos (ACGT) preparadas sintéticamente y que son complementarias a zonas específicas de la cadena del 16S ARNr que permiten identificar a un microorganismo o grupo dependiendo de la especificidad de la cadena. A estas cadenas sintéticas se les denomina sondas de oligonucleótidos y llevan adherido a su molécula un tinte fluorescente. Estas sondas de oligonucleótidos son muy estables, fáciles de conseguir, relativamente baratas, de fácil manejo, específicas, penetran bien en las células, dan resultados reproducibles y los tintes con los que están marcadas no interfieren en la hibridación. Esta sonda ha de introducirse en el interior de las células que se quieren identificar para lo que se llevan a cabo una serie de procedimientos con el fin de hacer que la pared celular sea permeable a la sonda, y que existan las condiciones ambientales adecuadas para que está se acople a la zona específica del 16S ARNr. Una vez la sonda está unida podemos observar al microscopio de epifluorescencia las células. Aquellas que tengan la sonda dentro “están marcadas” y por tanto emiten fluorescencia cuando se observan al microscopio de epifluorescencia, es decir se ven de color. Mientras que la composición de las aguas residuales urbanas está bien definida y la concentración de sus componentes no sufre grandes variaciones, no ocurre lo mismo para las aguas residuales industriales. Sus características van a depender del proceso en que se generen, lo que conlleva un estudio específico para cada tipo de agua antes de la aplicación del proceso de tratamiento biológico. Un factor importante en la dinámica de formación de los gránulos y en su estructura es el tipo de substrato empleado. Por lo tanto, será de interés estudiar la formación de los gránulos y sus características físicas en distintos tipos de aguas residuales, dado que van a condicionar tanto la capacidad de tratamiento del sistema como el post-tratamiento del lodo generado. O-12 Obxectivos e Resumo comportamento de gránulos, os procesos biolóxicos de eliminación de nitróxeno (nitrificación, desnitrificacion e Anammox) así como a tecnoloxía de membrana. Nos últimos anos, a investigación sobre os procesos de granulación aerobia/anóxica/anaerobia foi moi extensa. Ata a data, a maioría da biomasa obtida como gránulos aerobios tivo lugar nos reactores secuenciais descontinuos (SBR). Estes sistemas SBRs son capaces de desenrolar procesos aerobios con menos producción de lodo e maiores velocidades de conversión que nas tradicionais plantas de lodos activos. Debido a súa estructura moi compacta pódense obter altas concentracións de biomasa nestes sistemas e ademais a carga volumétrica pode ser tamén elevada. Ademais, como a tecnoloxía granular se basea en un só reactor (SBR); todas as fases operacionais lévanse a cabo no mesmo reactor: enchido, reacción, decantación e vertido. Este feito implica a necesidade de usar sistemas máis pequenos. Diferentes parámetros afectan á formación de gránulos aerobios/anóxicos/anaerobios en SBR como por exemplo, o rendemento celular dos microorganismos empregados, as forzas de estres que dependeran das condicións hidrodinámicas do reactor, a selección de biomasa por medio da velocidade de decantación, tipo de substrato, DQO, carga de nitróxeno e concentración de osíxeno. O proceso Anammox é unha alternativa para eliminar compoñentes de nitróxeno de augas residuais con alta carga nitroxenada e con baixo contido de materia orgánica, en vez dos procesos convencionais de nitrificación/desnitrificación. Recentemente incrementáronse os traballos sobre o proceso Anammox. Sen embargo, non hai moitos traballos relacionados con aspectos de enxeñería para poder levar a cabo o proceso a escala real. Por iso, neste traballo presentarase especial atención a estes aspectos. No Capítulo 2 describiranse os métodos analíticos empregados durante este estudio. Esto inclúe, tanto os parámetros convencionais usados para a caracterización de augas residuais (materia orgánica, compostos de nitróxeno, pH, concentracións de carbono e de sólidos), como a caracterización da biomasa. Esta caracterizouse por medio de parámetros como a densidade dos gránulos, o índice volumétrico de lodos, e técnicas como o análise de imaxe dixital, a microscopía O-13 Obxectivos e Resumo electrónica e a observación con lupa. A identificación das diferentes poboacións presentes na biomasa levouse a cabo empregando a técnica FISH (Fluorescent In Situ Hybridisation). O primeiro paso foi estudiar a formación do lodo granular en dous reactores secuenciais a escala de laboratorio (SBR), alimentados un deles con auga residual sintética e outro con auga industrial procedente dun laboratorio de análise de mostras lácteas. Ambos reactores operáronse en condicións similares durante a maioría do período experimental. Sen embargo, nun dos reactores (R1) introduciuse unha fase anóxica o inicio do ciclo de operación de entre 10 e 30 minutos de duración. As velocidades de carga orgánica e nitroxenada (VCO e VCN) aplicadas a ambos reactores foron moi altas alcanzándose valores de 7 g DQO/(L·d) e 0,7 g N/(L·d). Os porcentaxes de eliminación de nitróxeno foron do 70% en ambas unidades incluso considerando que R2 se operou sempre en condicións aerobias. Os gránulos obtidos nos dous sistemas tiveron unha morfoloxía similar e o tamaño deles estivo comprendido entre 0,25 e 4,0 mm (Capítulo 3). O obxectivo do Capítulo 4 foi obter un lodo granular nitrificante partindo do lodo heterótrofo diminuíndo a relación DQO/N ata eliminar completamente a DQO do medio. A estructura dos gránulos mantívose a pesar dos cambios na alimentación e a concentración de sólidos no efluente diminuíu ata 10 mg SST/L cando o acetato foi eliminado do medio da alimentación. Outro obxectivo deste capitulo foi estudiar o efecto das diferentes relacións carbono/nitróxeno (DQO/N) na alimentación sobre a producción de compostos nitroxenados no efluente. Para isto, ensaiáronse diferentes relacións DQO/N (15; 7; 5; 2,5; 1,25 y 0 g/g), obtendo para todas elas porcentaxes de eliminación de materia orgánica o redor do 90%. Os cambios na relación DQO/N tiveron como resultado a obtención de diferentes compostos de nitróxeno no efluente. A eliminación de nitróxeno levouse a cabo tanto mediante a asimilación deste composto por parte das bacterias para o crecemento, como por procesos de nitrificación-desnitrificación. O predominio dun o outro mecanismo dependeu da relación DQO/N que se empregase na alimentación. O-14 Obxectivos e Resumo Estudiouse tamén o efecto das condicións hidrodinámicas (forzas de estres e configuración do reactor) sobre a formación de gránulos nun SBR cunha relación H/D (altura/diámetro) de só 2,5. Neste sistema, tamén se estudiou a dependencia da concentración da materia orgánica (carbono orgánico total) na obtención de gránulos con unhas determinadas propiedades físicas (Capítulo 5). No Capítulo 6 evalúouse ó efecto das condicións de operación hidrodinámicas no proceso Anammox en diferentes sistemas SBR, tanto con mixtura por axitación mecánica (reactor SBRM) como por fluxo de gas (reactores SBRF1 e SBRF2). O reactor SBRM operouse durante máis de 200 días a diferentes velocidades de axitación (60-250 rpm) e os reactores SBRF1 e SBRF2 operáronse durante máis de 100 días a diferentes velocidades de gas (3,53-12,35 cm/min). De esta forma, os reactores expuseronse a diferentes condicións de estres e estudiouse como estas forzas afectaban o comportamento dos gránulos Anammox. A velocidade de carga nitroxenada a que operou o reactor estivo comprendida entre 0,05 g N/(L·d) e 0,3 g N/(L·d), sendo o último valor o utilizado durante a operación en condicións estables. O porcentaxe de eliminación de nitrito (substrato limítante) foi do 98% durante a maioría do período operacional. A actividade específica Anammox da biomasa foi practicamente constante e estivo entorno a 0,4 g N/(g VSS·d) para o SBRM e o redor de 0,35 g N/(g VSS·d) para o SBRF1, 2. O diámetro medio dos gránulos foi de 0,64 e 0,75 mm para SBRM e SBRF1, 2, respectivamente. Os resultados obtidos indican que hai un valor límite tanto de axitación (180 rpm) como de velocidade de gas (7,39 cm/min) para que o proceso Anammox se leve a cabo de forma satisfactoria. No reactor SBRM, cando se operou a 250 rpm, a actividade Anammox diminuíu o redor dun 45%, incrementándose con elo a concentración de sólidos no efluente a 0,2 g SST/L e a concentración de nitrito a 60 mg N/L. No caso dos reactores SBRF, cando se operaron a 9,7 cm/min, a actividade Anammox diminuíu un 85%, e o diámetro medio dos gránulos tamén diminuíu nun 30%, ademais de producirse unha acumulación de 70 mg N/L de nitrito. A pesar de que os sistemas SBR granulares permiten a acumulación de altas cantidades de biomasa dentro do reactor, a calidade do efluente está normalmente O-15 Obxectivos e Resumo limitada polo contido de sólidos en suspensión. A utilización de postratamentos, como por exemplo, os sistemas de membranas, permiten a mellora na calidade do efluente tanto en termos de sólidos en suspensión como na calidade microbiolóxica. No Capítulo 7 estudiouse a eliminación de compoñentes patóxenos da auga usando un SBR e unha membrana acoplada en serie. O uso da membrana, non só mellorou a calidade do efluente en termos de sólidos en suspensión senón que tamén en termos microbiolóxicos. Observouse unha eliminación parcial de coliformes fecais e Escherichia coli no efluente do SBR, previo a filtración pola membrana. A utilización da membrana asegurou unha total eliminación de coliformes no permeado final. Eliminouse máis dun 95% da materia orgánica, sólidos en suspensión e bacterias coliformes. O-17 Objectives and Summary In this work, different studies referred to the biological treatment of wastewaters with high nutrients concentration are presented. The conventional wastewater treatment installations have some inherent disadvantages, like the low volumetric conversion capacities, focussed mainly to the removal of easily degradable organic compounds and the high amounts of sludge production. To be able to cope with more stringent regulations, e.g., regarding to nitrogen and micropollutants removal, the development of new processes and technologies is required. In the present thesis the most favourable hydrodynamic conditions to develop the granules in aerobic conditions will be studied, with the further investigation of the effect of the wastewater composition on the granules formation. The development and application of granular systems will be performed both with wastewater characterized by its high Carbon/Nitrogen (C/N) ratio, using the nitrification-denitrification processes, and also with wastewater having a low C/N ratio, using the advanced processes of anaerobic ammonia oxidation (Anammox). Different operational conditions will be tested in order to maximize the organic matter and nitrogen removal efficiencies for each wastewater studied. The granular sludge produced during the operation of the reactors will be quantified and characterized. In Chapter 1, a literature overview related to aerobic/anoxic/anaerobic granulation, including granules formation and performance, biological nitrogen removal processes (nitrification, denitrification and Anammox) and membrane O-18 Objectives and Summary technology is presented. In recent years, the research on aerobic/anoxic/anaerobic granulation has been intensive. So far, most of the biomass obtained as aerobic granules is formed in sequencing batch reactors (SBR). These SBR systems are suitable to perform aerobic processes with less sludge production and higher conversion rates than in conventional activated sludge plants. Because of the compact structure of the aerobic granules, high biomass concentrations can be obtained in these systems and therefore the volume load of these reactors can be high. Since the aerobic granular sludge technology is based on a one-reactor system (SBR); all operational phases: influent feeding, reaction, settling and effluent withdrawal take place in one reactor. This fact involves the necessity of smaller reactor systems. The formation of aerobic/anoxic/anaerobic granules in SBR is affected by different parameters, e.g. biomass yields of the involved organisms, shear stress depending on the hydrodynamics of the reactor, biomass selection by means of the settling rate, the type of substrate, COD and N-load and oxygen concentration are important parameters. The Anammox process is an alternative to remove nitrogen compounds from high nitrogen loaded wastewater with low organic matter content, instead of the traditional combined nitrification/denitrification processes. Recently the number of research works focused on the study of the Anammox process has increased. Nevertheless, there are scarce studies related to the engineering aspects to implant this process at full scale. In this work those aspects are evaluated. In Chapter 2, the analytical methods used in this work are described. It comprises the conventional parameters used for wastewater (organic matter, nitrogen compounds, pH, dissolved oxygen, solids and carbon compounds concentrations) and the biomass characterisation. The biomass was characterised by means of parameters such as granules density, volumetric sludge index and techniques such as digital image analysis, electronic microscopy and O-19 Objectives and Summary stereomicroscope. Identification of the different populations present in the biomass samples was researched by Fluorescent In Situ Hybridisation (FISH). The first step was to study the granular sludge formation in two laboratory scale sequencing batch reactors (SBR), fed with synthetic and industrial wastewater produced in a laboratory for analysis of dairy products. Both reactors were operated under similar conditions during most of the experimental period. However, an anoxic phase between 10 and 30 min was included at the beginning of every cycle of operation of R1, but not in R2. Organic and nitrogen loading rates (OLR and NLR) applied to both systems were high, up to 7 g COD/(L·d) and 0.7 g N/(L·d). Nitrogen removal efficiency was 70% in both units even considering that R2 was operated always under aerobic conditions. Granules with similar morphology were developed in both systems. Granular size distribution was comprehended between 0.25 and 4.0 mm for both systems (Chapter 3). The objective of Chapter 4 was to obtain a nitrifying granular sludge from heterotrophic sludge by decreasing the COD/N until COD was completely eliminated. In spite of the changes in the feeding composition the granules maintained their structures and the solids content in the effluent was reduced to 10 mg TSS/L when acetate was removed from the feeding media. Another objective of this chapter was to study the effect of different carbon to nitrogen ratios (COD/N) in the feeding on the production of nitrogen compounds in the effluent. Different COD/N ratios of 15, 7, 5, 2.5, 1.25 and 0 g/g in the feeding were tested. The COD removal percentage was around 90% during the whole operational period. Changes on the COD/N ratio provoked the presence of different concentrations of nitrogen compounds in the effluent. The N removal percentages obtained in the reactor were up to 55%. Removal of ammonia was carried out by both assimilation and simultaneous nitrification-denitrification processes. The predominance of each mechanism was related to the COD/N ratio in the feeding media. The effects of hydrodynamic conditions (shear force and reactor configuration) on aerobic granulation are studied in a SBR with an unusual H/D ratio of 2.5. The effect of different carbon to nitrogen ratios (TOC/N) in the feeding on the production of nitrogen compounds in the effluent are also studied. O-20 Objectives and Summary The dependence of the TOC concentrations in the influent on the granulation process are evaluated (Chapter 5). In Chapter 6, the effect of operating hydrodynamic conditions on the Anammox process are studied in SBR where complete mixture was achieved by means of mechanical stirring (SBRM) or gas flow (SBRF1 and SBRF2). The reactor SBRM was operated during 218 days under different stirring speeds (60- 250 rpm) and the reactors SBRF1 and 2 were operated for 140 and 110 days respectively under different upflow velocities (3.53-12.35 cm/min). In this way the reactors were exposed to different shear conditions and the stability and performance of the Anammox granules was studied. The nitrogen loading rate (NLR) fed to the SBR ranged from 0.05 g N/(L·d) to 0.3 g N/(L·d), being the latter the chosen value during stable conditions. The nitrite (limiting substrate) removal percentage was 98% during most of the operational period. The specific Anammox activity of the biomass was practically constant and around 0.4 g N/(g VSS·d) for the SBRM and 0.35 g N/(g VSS·d) for the SBRF2. The average feret diameter of the formed granules was 0.64 mm and 0.75 mm for the SBRM and SBRF1, 2, respectively. Limit values for the accurate operation of the Anammox granular systems were around 180 rpm and 7.39 cm/min for the SBRM and SBRF respectively. In the SBRM the Anammox activity decreased to 50% when a rotating speed of 250 rpm was tested and the average diameter decreased in 45%, the concentration of solids in the effluent increased to 0.2 g TSS/L and nitrite was accumulated in the reactor up to 60 mg N/L. In the case of the SBRF the Anammox activity decreased to 85% when upflow velocity of 9.7 cm/min was applied and the average diameter decreased in a 30% while nitrite accumulated in the reactor up to 70 mg N/L. Although granular SBR systems allow the accumulation of relative high amounts of biomass inside the reactors the effluent quality is usually limited by the suspended solids content. Utilization of post treatments, like membrane O-21 Objectives and Summary systems, allows the enhancement of the effluent quality in terms of suspended solids and presence of coliform bacteria. Wastewater reclamation was studied by using a lab-scale biological reactor and an external filtration membrane coupled in series (Chapter 7). The use of the membrane enhanced the quality of the produced effluent from the biological reactor in terms of suspended solids and presence of indicator bacteria. Partial removal of faecal coliforms and Escherichia coli was observed in the effluent of a SBR, previous to filtration by the membrane. The use of the membrane ensures a full removal of the indicator bacteria in the final permeate. More than 95% of the organic matter, suspended solids, and coliform bacteria were successfully removed. 1-6 Introduction In order to overcome those weaknesses, research has been devoted to the development of aerobic granulation technologies. 1.2.3. Aerobic granulation 1.2.3.1. Definition The development of biomass in the form of aerobic granules is being recently under study for its application to the removal of organic matter, nitrogen and phosphorus compounds from wastewater. Aerobic granules present several advantages compared to conventional activated sludge such as excellent settling properties, compact microbial structure, high biomass retention, the ability to withstand shock and toxic loadings, the presence of aerobic and anoxic zones inside the granules to perform different biological processes, etc. (Morgenroth et al., 1997; Beun et al. 1999; Peng et al. 1999; Tay et al. 2001a, b; Lin et al. 2003; Liu et al., 2003; Yang et al., 2003a; Arrojo et al., 2004; Liu and Liu, 2006). The definition of the aerobic granules was proposed at the “1st IWA- Workshop Aerobic Granular Sludge” (Munich, 2004) (de Kreuk et al., 2005) as: “Granules making up aerobic granular activated sludge are to be understood as aggregates of microbial origin, which do not coagulate under reduced hydrodynamic shear, and which settle significantly faster than activated sludge flocs.” The aerobic granules are considered as a stable structure meaning that the values of the sludge volumetric index after 10 and 30 minutes of settling (SVI10 and SVI30, respectively) should, for a certain sample, give similar values (Schwarzenbeck et al., 2004), Other characteristics of aerobic granules are:  The position of micro-organisms is fixed and it does not change quickly as in an activated sludge floc. The structure of a granule is determined in a matrix of biomass and EPS.  No carrier material is intentionally involved or added.  No thickening after settling or rapid settling of the aggregates occurs. 1-7 Introduction  The minimum size of granules should be around 0.2 mm (de Kreuk et al., 2005), in order to be able to separate them form a sludge sample by sieving. When an aggregate fulfils all characteristics as described above, it can be called aerobic granular sludge. 1.2.3.2. Aerobic granular reactor configuration So far, most research on aerobic granulation has been conducted in sequencing batch reactors (SBR) (Morgenroth et al., 1997; Beun et al., 1999), while no successful aerobic granulation has been observed in continuous culture systems. Compared to continuous operated reactor systems, the main feature of SBR systems is its cycle operation. Each operation cycle consisted of different phases: filling, aeration, settling, discharging, etc. In SBR systems the settling phase substitutes the performance of the settler in the continuously operated reactors. Furthermore the chosen short settling times are likely to exert a selection pressure on the sludge particles, i.e. only particles that can settle down within the given settling time are retained in the reactor, and otherwise they would be washed out of the system. The primary design criterium for the SBR is based on the assumption that sludge granules will be formed if flocs are washed out. Sludge granules have a high settling velocity compared to sludge flocs, because granules are denser. So granules require less time to settle than flocs. Therefore the time allowed for settling in the SBR cycle is the main design parameter. A short settling period will eventually select for biomass particles with a high settling velocity (Beun et al., 1999). Because the settling velocity is an important selection criterium, a high H/D ratio (column height/column diameter) is advantageous. A high H/D ratio and the absence of an external settler results in a reactor with a small footprint. Besides, the good settling characteristics allow a short stand-still time for settling, allowing more time for biological purification. Previous research showed that selection pressure in terms of upflow velocity was a driving force towards successful anaerobic granulation in upflow anaerobic 1-8 Introduction sludge blanket (UASB) reactors (Hulshoff et al., 1998; Alphenaar et al., 1993). Although SBR has been extensively used in research on aerobic granulation, the mechanism of aerobic granulation in SBR are not fully understood and especially there is still no consensus on the principal driving force of aerobic granulation. 1.2.3.3. Aerobic granules formation Aerobic granulation can be regarded as the gathering together of cells through cell-to-cell immobilization to form a stable, contiguous, multicellular association. Evidence shows that aerobic granulation is a gradual process from seed sludge to compact aggregates, further to granular sludge and finally to mature granules (Tay et al., 2001a). Obviously, for cells in a culture to aggregate, a number of conditions have to be fulfilled. Existing literature on aerobic granule sludge typically focuses on a few parameters that influence granule formation: - Substrate composition - Feast-Famine regime - Hydrodynamic shear force - Short settling times - EPS formation - Inclusion of divalent cations. Substrate composition Aerobic granules have been successfully cultivated with a wide variety of substrates including glucose, acetate, ethanol, phenol and industrial wastewater (Beun et al., 1999; Dangcong et al.,1999; Peng et al., 1999; Tay et al., 2001a, 2003a; Tay et al., 2002a; Moy et al., 2002; Jiang et al., 2002; Yang et al., 2003a; Schwarzenbeck et al., 2005; Morgenroth et al., 1997; Arrojo et al., 2004; Ramadori et al., 2006; de Kreuk and van Loosdrecht, 2006). However, granule microstructure and species diversity appear to be related to the type of carbon source. The glucose-fed aerobic granules have exhibited a filamentous structure, while acetate-fed aerobic granules have had a nonfilamentous structure in which rod like species of bacteria predominated. Aerobic granules have been also cultivated with nitrifying bacteria and an inorganic carbon source (Tay et al., 1-9 Introduction 2002b; Tsuneda et al., 2003; Mosquera-Corral et al., 2005a; Tsuneda et al., 2006). More recently, aerobic granules were also successfully developed in laboratory-scale SBR for treating particulate organic matter-rich wastewater (Schwarzenbeck et al., 2005). From this research it can be stated that almost any wastewater with enough biodegradable organic matter content is suitable to be treated in an aerobic granular SBR. Special attention must be paid to specific contaminants which could affect the activity of the system. Feast - Famine regime The SBR reactors are operated in sequencing cycles of feeding, aeration, settling and discharging of supernatant. In SBR systems, the aeration period actually consists of two periods: a degradation period in which the substrate is depleted to a minimum, followed by an aerobic starvation period in which the external substrate is no longer available. Thus, it is likely that micro-organisms in SBR systems are subjected to a periodic feast and famine regime, called periodic starvation (Tay et al., 2001a). It was proposed that under the periodic feast-famine conditions, bacteria become more hydrophobic and high cell hydrophobicity facilitates microbial aggregation (Tay et al., 2001a; Bossier and Verstraete 1996; Liu et al., 2004a), meaning that this periodic regime in SBR systems acts as a kind of microbial selection pressure. When bacteria are subjected to a periodic feast-famine regime, microbial aggregation could be an effective strategy for cells against starvation. However, more recent research showed that aerobic granules could not be successfully developed if the settling time in SBR was not properly controlled, even though a periodic feast-famine regime was present (Qin et al., 2004a,b). Negative effects of nutrient starvation on the surface properties of aerobic granules in terms of cell hydophobicity and the content of extracellular polysaccharides were also observed (Zhou, 2004). In addition, when the starvation time in SBR was reduced from 3 h to below 30 min, no significant impact on aerobic granules was observed. This may imply that the periodic feastfamine regime could favour aerobic granulation, but so far there is no solid experimental evidence to show that starvation acts as an inducing force of aerobic granulation in SBR. 1-10 Introduction Hydrodynamic shear force Evidence shows that a high shear force favours the formation of aerobic granules and granule stability (Shin et al., 1992; Tay et al., 2001a; Liu ant Tay, 2006; Iaconi et al., 2006). It was found that aerobic granules could be formed only above a threshold shear force value in terms of superficial upflow air velocity above 1.2 cm/s in a column SBR, and more regular, rounder, and compact aerobic granules were developed at high hydrodynamic shear force (Tay et al., 2001a; Wang et al., 2005). The density and strength of the granules were also proportionally related to the applied shear force (Tay et al., 2003b). These observations may imply that the structure of aerobic granules is mainly determined by the hydrodynamic shear force present in a bioreactor. However, extracellular polysaccharides can mediate both cohesion and adhesion of cells and play a crucial role in maintaining the structural integrity in a community of immobilized cells. Tay et al. (2001a) reported that the production of extracellular polysaccharides was closely associated with the shear force and the stability of aerobic granules was found to be related to the production of extracellular polysaccharides (Tay et al., 2001c). The extracellular polysaccharides content normalized to protein content, increased with the shear force stimulated bacteria to secrete more extracellular polysaccharides. In fact, shear force-induced production of extracellular polysaccharides has been observed in biofilms (Ohasshi and Harada, 1994). Consequently, the enhanced production of extracellular polysaccharides at high shear can contribute to the compact and stronger structure of aerobic granules. Effects of shear on micro-organisms and aggregates have been discussed further elsewhere (Chisti, 1999). Tay et al. (2004) found how superficial upflow air velocity and type of carbon source affected the stability of aerobic granules in a Sequencing Batch Airlift Reactor. At a low superficial velocity, an outbreak of filamentous microorganisms was observed that gave rise to a poorly settling sludge and eventual biomass washout. When a higher superficial velocity was used, granules with significantly improved settling characteristics were obtained. In most discussions about shear, the difficulty of measuring shear plays a role as well as the oxygen concentration. In most cases both parameters are related, 1-11 Introduction meaning that when low superficial velocities are tested low dissolved oxygen (DO) concentrations are reached and, as a consequence, no stable granular biomass can be obtained due to DO limitation. Short settling times Strategies to limit the amount of flocs in an aerobic granule system include the use of short settling and discharging times. In a SBR, wastewater is treated in successive cycles, each lasting a few hours. At the end of every cycle, the biomass is settled before the effluent is withdrawn. Sludge that cannot settle down within given settling time could be washed out of the reactor through a fixed discharge port. Basically, a short settling time preferentially selects for the growth of good settling bioparticles. Thus, the settling time exerts a major hydraulic selection pressure on the microbial community. Qin et al. (2004a, b) studied the effect of settling time on aerobic granulation in SBR systems and found that aerobic granules were successfully cultivated and became dominant only in SBR operating at a settling times of less than 5 min, while a mixture of aerobic granules and suspended sludge developed in SBR run at longer settling times. In aerobic granulation research, a short settling time has been commonly employed to enhance aerobic granulation in SBR (Jiang et al., 2002; Lin et al., 2003; Liu et al., 2003; Yang et al., 2003b; Wang et al., 2004; Hu et al., 2005). In fact, at a long settling time, poorly settling sludge flocs cannot be effectively withdrawn; and they may outcompete granule-forming bioparticles. As a result, aerobic granulation could fail in SBR run at longer settling times. This seems to indicate that aerobic granules can form only at short settling times below a critical level being the settling time a decisive factor in the formation of aerobic granules in SBR. It was recognized that the selection pressure imposed by short settling times should be more important in fully aerobic systems, but in anaerobic-aerobic systems with phosphate accumulating organisms (PAOs), the settling criteria seemed less important because of the inherent tendency of PAOs to aggregate. EPS formation Literature reports conflicting data regarding the function of the extracellular polymeric substances (EPS) on the formation of aerobic granules (de Kreuk et al., 1-12 Introduction 2005). Some researches indicated that EPS content increases with granulation, that there exist differences in loosely bound and tightly bound EPS and that within the granule structure insoluble versus soluble polysaccharide gradients occur. The EPS could be the glue between the micro-organisms present in an aggregate and EPS may have important functions with respect to cell metabolism. It has been proposed that exo-enzymes are often an integral part of the EPS enabling cells to get access to substrate of larger molecule size and that EPS could be important to protect cells against toxic substances because of its absorptive capacity. van Loosdrecht et al. (2005) agree on the importance of EPS and that more research is needed before conclusions about the role of EPS can be drawn. Inclusion of divalent cations Finally another parameter, possibly influencing the granule formation, is the addition of divalent cations such as iron and calcium to help the granule formation. Tsuneda et al. (2005) suggested that high concentrations of cations might increase the rate of granule formation and might influence the stability of the reactor system. Tsuneda et al. (2006) obtained nitrifying granules using a industrial wastewater which container a high concentration of ammonium and inorganic salts such as sodium chloride and sodium sulphate. Jiang et al. (2003) reported that addition of Ca+2 accelerated the aerobic granulation process. With addition of 100 mg Ca+2/L, the formation of aerobic granules took 16 days compared to 32 days in the culture without Ca+2 additions. The Ca+2 augmented aerobic granules, which also showed better settling and strength characteristics and had higher polysaccharides content. It has been proposed that Ca+2 bind to negatively charged groups presents on bacterial surfaces and extracellular polysaccharides molecules and thus acts as a bridge to promote bacterial aggregation. All different parameters that were discussed seemed to play a role in the granule stability. There was no concluding agreement on which of these parameters is the crucial one and most probably it is a combination of all. Results obtained from aerobic granulation results must be compared to those obtained 1-13 Introduction from bulking sludge in order to be able to better understand the granulation procedure and the main parameters involved. 1.2.3.4. Selection by settling rate Different mechanisms important for aerobic granulation have been described in the literature, e.g. yields of the involved organisms, shear and selection by settling rate. Selection of granules from a mixture in a SBR can be easily based on the difference in settling velocity between the granules (fast settling biomass) and the filaments and flocs (slow settling biomass). Biomass granules, filaments and flocs were present as a mixture in the reactor. Selection of the biomass granules from the mixture occurred during the settling period (Fig 1.1). The settling length is chosen to guarantee that particles with a settling velocity larger than 10 m/h are effectively retained in the reactor. The rest of the biomass does not settle fast enough and will be taken out with the effluent (Beun et al., 2002). Figure 1.1. Selection of well settling granules in an aerobic granular SBR (Beun et al., 2002). 1.2.3.5. Storage of substrates Since the SBR systems are discontinuously fed reactors, the sludge present in these units experiences periods with external substrate availability (feast period) and periods without external substrate availability (famine period). Under these conditions the micro-organism are able to accumulate substrate as internal storage 1-14 Introduction products in their cells like glycogen, lipids or polyhydroxyalkanoates (PHA). They can be used by the micro-organisms to survive famine periods and probably also to regulate their growth rate (Zevenhuizen and Ebbink, 1974). Glycogen is usually formed when sugar are present in the liquid. The role of lipids as storage product is unclear. Polyhydroxy butyrate (PHB) is the most dominant storage polymer as it is directly formed from the central metabolite acetyl-CoA (Doi, 1990). Although the presence of storage polymers in activated sludge has often been reported in literature (Zevenhuizen and Ebbink, 1974; Doi et al., 1992), only since recently it is generally accepted that they play an important role in especially fed activated sludge processes (van Loosdrecht et al., 1997) which could be somehow related to the selection for granule forming micro-organisms. Although recent research indicated that filamentous bacteria and bacteria forming aggregates have similar ability to store PHB (Martins et al., 2003). The knowledge of the PHB metabolism in activated sludge is however limited. In the past, research was mainly focused on the metabolic pathway of PHB formation and degradation (Dawes and Senio, 1973; Doi, 1990; Steinbuchel, 1996), on the enzymes involved in the metabolic reaction steps (Dawes and Senio, 1973; Haywood et al., 1989; Anderson and Dawes, 1990; Steinbuchel, 1996), and on the possibilities of industrial production of bacterial PHB (Byrom, 1987; Lee, 1996; Choi and Lee, 1997; van Wegen et al., 1998). PHB exists in the cytoplasm of the cells as granules surrounded by a membrane. The PHB granules have typical diameters of 0.2 to 0.5 µm. It has been found that in most micro-organisms the formation and degradation of PHB occur via a cyclic metabolic pathway (Figure 1.2) (Dawes and Senior, 1973; Doi, 1990). Acetyl-CoA is the central metabolite in the formation and degradation of PHB. Since acetate is one of the most important substrates in wastewater, this compound is used as a model substrate. Acetate is taken up by the microorganisms and converted into acetyl-CoA. 1-15 Introduction Figure 1.2. Cyclic metabolic pathway of PHB (Dawes and Senior, 1973; Doi, 1990). In a dynamic system, storing substrate as PHB and thus balancing their growth rate gives these micro-organisms a competitive advantage compared to micro-organisms a competitive advantage compared to micro-organisms that can not store substrate. Bacteria that are not able to store substrate can grow only during the period with external substrate available. During the famine period they can not grow and are even subjected to starvation. In a wastewater treatment system where the sludge usually experiences periods with and without external substrates available, the bacteria that are able to store substrate will finally outcompete the ones that can not store. More insight into the kinetics and stoichiometrics of PHB production and consumption is needed. 1.2.3.6. Removal of N- containing compounds in the granule Wastewaters, especially those originating from industries, usually contain ammonium and organic matter. The SBR, containing granular sludge, favours the removal of N-Compounds from wastewater via simultaneous nitrification and denitrification (Beun et al., 2001; Mosquera-Corral et al., 2005a; Kishida et al., 2006). The distribution of autotrophic and heterotrophic biomass in the granules plays an important role (Figure 1.3) (Beun et al., 2001). 1-22 Introduction treating ammonium-rich leachate (Helmer et al., 2001; Egli et al., 2001), a trickling filter treating wastewater (Schmid et al., 2000), fixed-and fluidised-bed reactors and SBRs treating a synthetic medium (Strous et al., 1997a,1998). Application of the Anammox process is limited by the availability of Anammox biomass. The isolation and enrichment of Anammox from a mixture of bacterial populations requires the optimisation of conditions favouring the Anammox process, while limiting the growth of any other kind of microbial population. In particular, since the Anammox process is anaerobic, the exclusion of oxygen is essential especially during the start-up of reactors. From the point of view of the industrial application the principal disadvantage of this process relies on the presence of different inhibitors (Strous et al., 1997b; Dapena-Mora et al., 2006a,b) and the slow growth rate of the Anammox micro-organisms (doubling times in the range of 11 - 15 days (Strous et al., 1999; Dapena-Mora et al., 2004a). For this reason long starting up periods are needed to achieve stable operation conditions. On the other hand, this slow growth rates also imply the operation of systems with high biomass retention properties to maintain high Solids Retention Times (SRT). When these conditions are achieved biomass concentrations in the reactor are high enough to treat relative high nitrogen loading rates. The Sequencing Batch Reactor (SBR) systems have been found to be appropriate to fulfil these conditions according to Strous et al. (2002) and van Dongen et al. (2001). Dapena-Mora et al. (2004a, 2004b) went further and showed that the SBR is a suitable system to grow Anammox biomass in form of granular sludge. When stable granular sludge is produced it is retained inside the reactor easier than the flocculent sludge due to its better settleability characteristics. Since the Anammox biomass can grow forming granules it is important to have favourable conditions for granulation in order to obtain a stable Anammox population. Another advantage of the SBRs is the feasibility to change the operational strategy to optimize the efficiency (Humpherys and Banks, 1995) and the easy control of the process (Andreottola et al., 2001). Despite the fact that the SBR is a suitable system to grow Anammox bacteria (Strous et al., 1998), it still may present eventual flotation and biomass wash-out problems (Wilderer et al., 2001). 1-23 Introduction Dapena-Mora et al. (2004c) improved the capacity to retain biomass of an Anammox SBR by changing the distribution of the SBR operational cycle. The addition of the mixing period in the operational cycle provoked an enhancement in the biomass retention inside the reactor. 1.4. Membrane Bioreactor With the increased worldwide pressure on water resources, effluent recycle and reuse are developing for irrigation, reclamation and agriculture, as well as for both indirect and direct potable water supply (Côté et al., 1997). Until recently, the approach has consisted of providing advanced treatment to a secondary effluent to meet the standards for reuse. For irrigation this treatment complement may be limited to filtration and disinfection. For groundwater recharge, the treatment complement normally involves reverse osmosis (RO) and may become rather complex. Current and impending legislation in the EC on wastewater effluent discharge has led to the need for enhanced treatment processes capable of removing high percentages of BOD, suspended solids, nitrogen, phosphorus and bacteria (Council Directive, 1975; 1991). In the field of granulation systems the treatment efficiency is usually limited by the difficulties in separating suspended solids. Sequencing batch reactor (SBR) processes offer several advantages over other types of activated sludge reactors. In particular, the hallmark of SBR design is its inherent flexibility of cyclic phasing. The cycle format can be easily modified at any time to offset changes in process conditions, influent characteristics or effluent objectives (Epa, 1999; Pavelj et al., 2001; Pochana and Keller, 1999; Kang et al., 2003). However, SBR has a potential risk in that poor clarification and a turbid effluent are associated with it. Combining a membrane process with an SBR system provides procedural advantages for both processes. The use of membranes can reduce the length of the operational cycle since membrane separation requires no settling and clear-water can be extracted even during the mixing time. In addition, the separation of biological sludge by means of a membrane leads to complete retention of biomass 1-24 Introduction resulting in a high mixed liquor suspended solids concentration. This allows a very high treatment capacity for a membrane-coupled sequencing batch reactor (MSBR) (Krampe and Krauth, 2000). In a MSBR system, it would be very important, and also difficult to select the most appropriate SBR phase in which membrane filtration could be performed at its best. The reason for this relies on the many types of SBR systems currently in use which operate in different operation modes such as: continuous influent/time based, non-continuous influent/time based, volume based, and intermittent cycle system, and various other system modifications (Banas et al., 1999; Schleypen et al., 1997; Ketchum, 1997; Irvine et al., 1997). Although combination of membrane filtration and SBR should be reengineered to get a MSBR of good performance, the efficiency of membrane process in MSBR would certainly be dependent on the physicochemical and biological conditions of each SBR phase as well as the type and cycle format of the SBR. In the past 20 years, the membrane bioreactor (MBR) process has been studied in numerous ways. The main goal of these studies was focused on exploring the feasibility of the MBR process and methods for process enhancement. Emphasis was on effluent quality achieved, higher sludge loading, system compactness, water re-use, and the potential of “zero” sludge growth. In an MBR solid/liquid membrane filtration occurs either within the bioreactor (submerged configuration, Fig 1.6a or externally through recirculation Fig 1.6b) subject to a pressure drop across the membrane generated by either hydraulic head or a fitted pump. The ultratiltration (UF) or microfiltration (MF) membrane separated the retained (or rejected) materials, principally solids and including micro-organism, from other material largely through sieving, allowing the water and most solute species to pass through the membrane. The membranes typically used in such applications have a pore size between less than 0.1 µm and 0.45 µm, which positions them between ultrafiltration and microfiltration (Figure1.7). These systems are described in greater details in the literature (Yamamoto et al., 1989; Chiemchaisri and Yamamoto, 1994; Mourato, 1996; Côté et al., 1997; Ueda et al., 1997; Buisson et al., 1998; Yoon et al., 2004). 1-25 Introduction The advantages offered by MBRs over the conventional activated sludge process (ASP) include a small footprint and reduced sludge production. Submerged MBRs take only half the land area of a conventional ASP, and sludge production in similarly approximately halved (Mayhew and Stephenson, 1997). Since sewage sludge disposal contributed significantly to overall operating costs, there are significant potential benefits in reducing its production (Gander et al., 2000). Figure 1.6. a) Side-stream MBR with a separate filtration unit with retentate recycled back to bioreactor; b) submerged MBR: filtration unit integrated into the bioreactor. Figure 1.7. Filtration processes versus pore sizes. 1-26 Introduction 1.4.1. Membrane performance The performance of a given membrane process is represented by: - The rejection, normally expressed as a function of the ratio of the respective concentrations of the target contaminant in the feed and the permeate product (or filtrate). - The specific permeate flux (flux per unit pressure) or permeability, sometimes expressed as the hydraulic resistance (inverse product of specific flux and viscosity), and the transient behaviour of this parameter. Rejection Rejection is the removal of particles, including biological and non-biological colloids and macromolecules, by sieving or adsorption. One of the main drivers for MBR technology is the ability of the systems to disinfect, resulting in an effluent free from pathogenic micro-organisms. This is an important consideration when discharge is to bathing waters (Council Directive, 1976), or if the water is to be reused. Rejection of both bacteria and viruses by both MF and UF membranes is known to be significant (Kolega et al., 1991; Chiemchaisri et al., 1992; Judd and Till, 2000; Madaeni et al., 1995). Chiemchairsi et al. (1992) showed that membranes with 0.03 and 0.1 µm pore size attained the same log reduction of coliphage viruses, and that improved rejection occurred with time owing to the build-up of the dynamic membrane. Madaeni et al. (1995) showed poliovirus removal to be enhanced by the addition of E.Coli to the viral culture in an MF process, possibly because of increased partial pore blocking (0.22 µm) but more likely to be caused by adsorptive retention of the virus on the larger E.Coli bacteria. Different authors (Ueda and Hata, 1999; Ueda et al, 1996, 1997; Kishino et al., 1996) have reported in several studies that more than 90% of organic matter, suspended solids, and coliform bacteria were successfully removed from a domestic sewage using different reactors with membranes. Permeate flux Permeate flux decline is influenced by a number of factors relating to the feed water (composition), the membrane (element geometry/configuration, area 1-27 Introduction and material composition), and operation (hydrodynamics). It is critically determined by the tendency of the membrane to be fouled by feed water components owing to their accumulation on the internal and external structures of the membrane (Visvanathan et al., 1989; Belfort et al., 1994). This increases the overall resistance to filtration (Belfort et al., 1994), thereby commensurately increasing the energy demands. The requirement for cleaning adds to the overall cost, as forces to membrane replacement in cases where cleaning fails to produce adequate flux recovery. Fouling most commonly takes place external to the membrane, forming a dynamic layer at the membrane surface. As most membrane processes operate in the crossflow mode, fouling through the formation of such a dynamic layer might be expected to reach equilibrium once the adhesive forces between the layer and the membrane substrate are balanced by the shear forces at the layer solution interface. In practice, equilibrium is not always attained, indicating some component of the overall hydraulic resistance to be time dependent. The flux decline rate generally decreases with time but increases with increasing operating flux or pressure, and the specific flux almost always increases with decreasing trans-membrane pressure (TMP). 1.4.2. Membrane materials and modules There are a number of different types of membrane materials, modules and associated systems that are utilized by the various classes of membrane filtration. While several different types of membrane modules may be used for any single membrane filtration technology, each class of membrane technology is typically associated with only one type of membrane module in water treatment applications. In general, MF and UF use hollow-fibre membranes and NF and RO use spiral-wound membranes. MCF (Membrane cartridge filtration) systems use flat sheet material configured into a cartridge filtration device. The terms hollow-fibre, spiral-wound, and cartridge refer to the module in which the membrane media is manufactured. 1-28 Introduction 1.4.2.1. Membrane materials The membrane material refers to the substance from which the membrane itself is made. Normally, the membrane material is manufactured from a synthetic polymer, although other forms, including ceramic and metallic membranes, may be available. Currently, almost all membranes manufactured for drinking water production are made of polymeric material, since they are significantly less expensive than membranes constructed of other materials. The material properties of the membrane may significantly impact the design and operation of the filtration system. For example, membranes constructed of polymers that react with oxidants commonly used in drinking water treatment should not be used with chlorinated feed water. Mechanical strength is another consideration, since a membrane with greater strength can withstand larger transmembrane pressure (TMP) allowing for greater operational flexibility and the use of higher pressures with pressure-based direct integrity testing. MF and UF membranes may be constructed from a wide variety of materials, including cellulose acetate (CA), polyvinyledene fluoride (PVDF), polyacrylonitrile (PAN), polypropylene (PP), polysulfone (PS), polyethersulfone (PES), or other polymers. Each of these materials has different properties with respect to surface charge, degree of hydrophobicity, pH and oxidant tolerance, strength, and flexibility. NF and RO membranes are generally manufactured form cellulose acetate or polyamide materials. 1.4.2.2. Membrane modules Membrane filtration media is usually manufactured as flat sheet stock or as hollow fibres and then configured into one of several different types of membrane modules. A membrane module represents the smallest discrete filtration unit in a membrane system. Module construction typically involves potting or sealing the membrane material into a corresponding assembly, which may incorporate an integral containment structure, such as with hollow-fibre modules. These types of modules are designed for long-term use over the course of a number of years. Spiral-wound modules are also manufactured for long-term use, although the design of membrane filtration systems that utilize spiral-wound 1-29 Introduction modules requires that the modules be encased in a separate pressure vessel that is independent of the module itself. Alternatively, a module may be configured as a disposable cartridge with a useful life that is typically measured in weeks or months rather than years. Membrane cartridges may either be inserted into pressure vessels that are separate from the module (as with spiral-wound modules) or manufactured within a casing that serves as an integral pressure vessel. Hollow-Fibre modules Most hollow-fibre modules used in drinking water treatment applications are manufactured to accommodate porous MF or UF membranes and designed to filter particulate matter. As the name suggests, these modules are comprised of hollow-fibre membranes, which are long and very narrow tubes that may be constructed of any of the various membrane materials. The fibres may be bundled in one of several different arrangements. In one common configuration used by many manufacturers, the fibres are bundled together longitudinally, potted in a resin on both ends, and encased in a pressure vessel that is included as a part of the hollow-fibre module. These modules are typically mounted vertically, although horizontal mounting may also utilized. One alternate configuration is similar to spiral-wound modules in that both are inserted into pressure vessels that are independent of the module itself. These modules (and the associated pressure vessels) are mounted horizontally. Another configuration in which the bundled hollow fibres are mounted vertically and submerged in a basin does not utilize a pressure vessel. A typical commercially available hollowfibre module may consist of several hundred to over 10,000 fibres. Although specific dimensions vary by manufacturer, approximate ranges for hollow-fibre construction are as follows: - Outside diameter: 0.5-2.0 mm - Inside diameter: 0.3-1.0 mm - Fibre wall thickness: 0.1-0.6 mm - Fibre length: 1-2 meters A cross section of a symmetric hollow-fibre is shown in Figure 1.8. 1-30 Introduction Hollow-fibre membrane modules may operate in either and “inside-out” or “outside-in” mode. In inside-out mode, the feed water enters the fibre lumen (i.e., centre or bore of the fibre) and is filtered radially through the fibre wall. The filtrate is then collected from outside of the fibre. During outside-in operation, the feed water passes from outside the fibre through the fibre wall to the inside, where the filtrate is collected in the lumen. Although inside-out mode utilizes a well-defined feed flow path that is advantageous when operating under a crossflow hydraulic configuration, the membrane is somewhat more subject to plugging as a result of the potential for the lumen to become clogged. The outside-in mode, utilizes a less well-defined flow feed flow path, but increases the available membrane surface area for filtration per fibre and avoids potential problems with clogging of the lumen bore. Both the inside-out and outside-in operating modes for hollow-fibre modules are illustrated in Figure 1.9. When a hollow-fibre module is operated in an insideout mode, the pressurized feed water may enter the fibre lumen at one or both ends of the module, with the filtrate exiting in the centre or end(s). In outsidein mode, the feed water typically enters the module in the centre at the ends and is filtered into the fibre lumen, where the filtrate collects before exiting at the end(s). Most hollowfibre systems operate in “dead-end” or direct filtration mode and are periodically backwashed to remove the accumulated solids. This module has been widely used for wastewater treatment (Tac-Hyum et al., 2003; Fatone et al., 2006; Artiga et al., 2005a), drinking water treatment and wastewater reclamation (Buttiglieri et al., 2005; Arrojo et al., 2005; Melin et al., 2006). Artiga et al. (2005a) used a hollow-fiber ultrafiltration membrane (Zenon ZW-10) with a pore size 0.04 µm and a nominal surface area of 0.9 m2 for the treatment of two industrial wastewaters (winery and tannery) in a submerged membrane bioreactor. They obtained COD removal percentages around 97% and 86% for winery and tannery wastewater, respectively. Artiga et al. (2005b) developed an innovative membrane-assisted hybrid bioreactor for treatment of tannery and fish canning wastewater. This system was composed by a hybrid circulating bed reactor coupled in series to an ultrafiltration hollow fiber module (Zenon, ZW-1). COD removal efficiency was 95%, while up to 97% of ammonia 1-31 Introduction removal was obtained. Moreover, the membrane filtration unit made it feasible to operate the reactor at high OLR without problems related to either the settling properties of the sludge or the drop in the nitrogen conversion, which usually occurs in other hybrid biological reactors operated at high OLR and NLR. Figure 1.8. Hollow Fibre Cross-Section Photomicrograph. (EPA, 2003) Figure 1.9. Inside-Out and Outside-In modes of operation. (EPA, 2003) 1-38 Introduction Chiemchaisri, C.; Wong, Y. K.; Urase, T.; Yamamoto, K. (1992). Organic stabilization and nitrogen removal in membrane separation bioreactor for domestic wastewater treatment. Water Science and Technology, 25 (10), 231-40. Chiemchaisri C. and Yamamoto K. (1994). Performance of membrane separation bioreactor at various temperature for domestic wastewater treatment. Journal of Membrane Science, 87, 11-129. Chisti Y. (1999). Shear sensitivity. In: Flickinger MC., Drew SW., editors. Encyclopedia of bioprocess technology: fermentation, biocatalysis and bioseparation, vol 5. New York: Wiley; 2379-406. Choi J. and Lee S.Y. (1997). Process analysis and economic evaluation for poly(3-hydroxybutyrate) production by fermentation. Bioprocess Engineering, 17, 335-342. Côté P., Buisson H., Pound Ch. and Arakaki G. (1997). Inmersed membrane activated sludge for the reuse of municipal wastewater. Desalination, 113, 189-196. Countil Directive of 8 December 1975 (1976). Concerning the Quality of Bathing Water, Official. J. Eur. Commun., L31. Countil Directive of 21 May 1991 (1991). Concerning Urban Waste Water Treatment, Official J.Eur. Commun., L135. Dangcong P., Bernet N., Delgenes J.-P. y Moletta R. (1999). Aerobic granular sludge-a case report. Water Research, 33(3), 890-893. Dapena-Mora A., Campos J.L., Mosquera-Corral A., Jetten M.S.M. and Méndez R. (2004a). Stability of the Anammox Process in a gas-lift reactor and a SBR. Journal of Biotechnology, 110 (2), 159-170. Dapena-Mora A., Van Hulle S., Campos J.L., Méndez R., Vanrolleghem P.A. y Jetten M.S.M. (2004b). Enrichment of Anammox biomass from municipal activated sludge: experimental and modelling results. Journal of Chemical Technology and Biotechnology, 79, 1421-1428. Dapena-Mora A., Arrojo B., Campos J.L., Mosquera-Corral A. y Méndez R. (2004c). Improvement of the settling properties of Anammox sludge in an SBR. Journal of Chemical Technology and Biotechnology, 79, 1417-1420. Dapena-Mora A., Campos J.L., Mosquera-Corral A. and Méndez R. (2006a). Anammox process for nitrogen removal from anaerobically digested fish canning effluents. Water Science and Technology, 53 (12), 265-274. 1-39 Introduction Dapena-Mora A., Fernández I., Campos J.L., Mosquera-Corral A.,Méndez R and Jetten M.S.M. (2006b). Evaluation of activity and inhibition effects on Anammox process by batch tests based on the nitrogen gas production. Enzyme and Microbial Technology (In press). Dawes E.A. and Senio P.J. (1973). The role and regulation of energy reserve polymers in microorganisms. Advances in Microbial Physiology, 10, 135-266. de Bruin L.M.M., de Kreuk M.K., van der Roest H.F.R., Uijterlinde C. and van Loosdrecht M.C.M. (2004). Aerobic granular sludge technology: and alternative to activated sludge. Water Science and Technology, 49 (11-12),1-7. de Bruin L.M.M., van der Roest H.F., de Kreuk M.K. and van Loosdrecht M.C.M. (2005). Promising results pilot research aerobic granular sludge technology at WWTP Ede. In: Aerobic Granular Sludge. Water and Environmental Management Series. IWA Publishing. Munich, (135-142). de Kreuk M.K., McSwain B.S., Bathe S., Tay S.T.L., Schwarzenbeck and Wilderer P.A. (2005). Discussion outcomes. Ede. In: Aerobic Granular Sludge. Water and Environmental Management Series. IWA Publishing. Munich, (165-169). de Kreuk M.K. and van Loosdrecht M.C.M. (2006). Formation of aerobic granules with domestic sewage. Journal of Environmental Engineering, 132 (6), 694-697. Doi, (1990), Microbial polyesters, New York, VCH Publishers. 156. Doi Y., Kawaguchi Y., Koyama N., Nakamura S., Hiramitsu M., Yoshida Y. and Kimura H. (1992). Synthesis and degradation of polyhydroxyalkanoates in Alcaligenes eutrophus. FEMS Microbiology Reviews, 103, 103-108. Egli K., Fanger U., Alvarez P.J.J., Siegrist H., van der Meer J.R. and Zehnder A.J.B. (2001). Enrichment and characterization of an anammox bacterium from a rotating biological contactor treating ammonium-rich leachate. Archives of Microbiology, 175, 198-207. EPA. (1999). Wastewater technology fact sheet sequencing batch reactor. Office of Water, United States Environmental Protection Agency, Washington DC. EPA(2003). Membrane Filtration Guidance Manual. United States Environmental Protection Agency. Etterer T. and Wilderer P.A. (2001). Generation and properties of aerobic granular sludge. Water Science and Technology 43 (3), 19-26. Fang H.H.P. and Chui H.K. (1993). Maximum COD loading capacity in UASB reactors at 37ºC. Journal Environmental Engineering, 119, 103-119. 1-40 Introduction Fatone F., Battistoni P., Pavan P. and Cecchi F. (2006). Application of a membrane bioreactor for the treatment of low loaded domestic wastewater for water re-use. Water Science and Technology, 53 (9), 111-121. Gander M., Jefferson B. and Judd S. (2000). Aerobic MBRs for domestic wastewater treatment: a review with cost considerations. Separation and Purification Technology 18, 119-130. Garrido, J.M., Moreno, J., Méndez-Pampín, R. and Lema, J.M. (1998). Nitrous oxide production under toxic conditions in a denitrifying. Water Research, 32, 2550-2552. Gejlbjerg B., Frette L. and Westermann P. (1998). Dynamics of N2O production from activated sludge. Water Research, 32 (7), 2113-2121. Goreau T.J., Kaplan W.A., Wofsy S.C., McElroy M.B., Valois F.W. and Wattson S.W. (1980). Production of NOx - and N2O by nitrifying bacteria at reduced concentrations of oxygen. Applied and Environmental Microbiology, 40 (3), 526-532. Guiot S.R., Pauss A. and Costerton J.W. (1992). A structured model of the anaerobic granule consortion. Water Science and Technology, 25 (7), 1-10. Haywood G.W., Anderson A.J. and Dawes E.A. (1989). The importance of PHB- synthase substrate specificity in polyhydroxyalkanoate synthesis by Alcaligenes eutrophus. FEMS Microbiology Letters, 57, 1-6. Haneda R.N., Ikegami R., Formulan C.A., Purqueiro B.M., Longo E., Fones S.R. (2006). Microfiltration with chemistry treating of comercial membranes and microporous tubes for retention of bacteria E.Coli on processing of wastewater of dairy products. Desalination, 200 (1-3), 313-315. Heijnen J.J., Mulder A., Weltevrede R., Holds P.H. and Van Leeuwen H.L.J.M. (1990). Large-scale anaerobic/aerobic treatment of complex industrial wastewater using immobilized biomass in fluidized bed and air-lift suspension reactors. Chemical Engineering Technology, 13, 202-208. Helmer C., Tromm C., Hippen A., Rosenwickel K.H., Seyfried C.F. y Kunst S. (2001). Single stage biological nitrogen removal by nitritation and anerobic ammonium oxidation in biofilm systems. Water Science and Technology, 43, 311-320. Henze M. (1991). Capabilities of biological nitrogen removal processes from wastewater. Water Science and Technology, 23, 669-679. 1-41 Introduction Hu L., Wang J., Wen X. and Qian Y. (2005). The formation and characteristics of aerobic granules in sequencing batch reactor (SBR) by seeding anaerobic granules. Process Biochemistry, 40, 5-11. Hulshoff P.L.W., Heijnekamp K. and Lettinga G. (1988). The selection pressure as a driving force behing the granulation of anaerobic sludge. In: Lettinga G., Zehnder A.J.B., Grotenhuis J.T.C., Hulshoff Pol L.W., editors. Granular anaerobic sludge: microbiology and technology. Wageningen: GASMAT, Lunteren; 153-161. Hulshoff P.L.W. (1989). The phenomenon of granulation of anaerobic sludge. PhD thesis, Wageningen Agricultural University, The Netherlands. Humphreys P.N. and Banks C.J. (1995). The use of sequencing batch activated sludge reactors to determine nitrogen balances and optimum periods of preaeration denitrification. Environmental Technology, 16, 549-558. Iaconi Di C., Ramadori R., López A. and Passino R. (2006). Influence of hydrodynamic shear force on properties of granular biomass in a sequencing batch biofilter reactor. Biochemical Engineering Journal, 30, 152-157. Irvine R.L., Ketchum L.H., Breyfogle R. and Barth E.F. (1983). Municipal application of sequencing batch treatment. Journal Water Pollution Control Federation, 55, 484-488. Irvine R.L., Wilderer P.A. and Flemming H.C. (1997). Controlled unsteady state processes and technologies-an overview. Water Science and Technology, 35, 1-10. Jetten M.S.M., Horn S.J. y van Loosdrecht M.C.M. (1997). Towards a more sustainable wastewater treatment system. Water Science and Technology, 35(9), 171-179. Jetten M.S.M. (1999). New pathways for ammonia conversion in soil and aquatic systems. Plant & Soil, 230, 9-19. Jiang H.L., Tay J-H and Tay S.T.L. (2002). Aggregation of immobilized activated sludge cells into aerobically grown microbial granules for the aerobic biodegradation of phenol.. Letters in Applied Microbiology, 63, 602-608. Jiang H.L., Tay J.H., Liu Y. and Tay S.T.L. (2003). Ca2+ augmentation for enhancement of aerobically grown microbial granules in sludge blanket reactors. Biotechnology Letters, 25, 95-99. Judd, S. J.and Till, S. W. (2000). Bacterial rejection in crossflow microfiltration of sewage. Desalination, 127 (3), 251-260. 1-42 Introduction Kang I.J., Lee C.H. and Kim K.J. (2003). Characteristics of microfiltration membranes in a membrane coupled sequencing batch reactor system. Water Research 37, 1192-1197. Ketchum Jr. LH. (1997). Design and physical features of sequencing batch reactors. Water Science and Technology, 35 (1), 11-8. Kishida N., Kim J., Tsuneda S. and Sudo R. (2006). Anaerobic/oxic/anoxic granular sludge process as an effective nutrient removal process utilizing denitrying polyphosphate-accumulating organisms. Water Research, 40, 2303- 2310. Kishino H., Ishida H., Iwabu H. and Nakano I. (1996). Domestic wastewater reuse using a submerged membrane bioreactor. Desalination 106 115-119. Kolega, M.; Grohmann, G. S.; Chiew, R. F.; Day, A. W. (1991). Disinfection and clarification of treated sewage by advanced microfiltration. Water Science and Technology, 23 (7-9), 1609-18. Krampe J. and Krauth K. (2000). Sequencing batch reactor with submerged hollow fibre membranes for the biomass separation. In: Proceedings of 2nd international symposium on sequencing batch reactor technology. Vol 2., 109- 15. Kuypers M.M.M., Sliekers A.O., Lavik G., Schmid M., Jorgensen B.B., Kuenen J.G., Sinninghe Damste J.S., Strous M. and Jetten M.S.M. (2003). Anaerobic ammomium oxidation by Anammox bacteria in the Black Sea. Nature, 422, 608-611. Kwok W.K., Picioreanu C., Ong S.L., van Loosdrecht M.C. M., Ng W.j. and Heijnen J.J. (1998). Influence of biomass production and detachment forces on biofilm structures in a biofilm airlif suspension reactor. Biotechnology and Bioengineering, 58, 400-407. Lee S.Y. (1996). Plastic bacteria? Progress and prospects for polyhydroxyalkanoate production in bacteria. Trends in Biotechnology, 14, 431-438. Lettinga G., van Velsen A.F.M., Hobma S.W., de Zeeuw W. and Klapwijk A. (1980). Use of the Upflow Sludge Blanket (USB) reactor concept for biological wastewater treatment, especially for anaerobic treatment. Biotechnology and Bioengineering, 22, 699-734. Li Y.S., Yan L.X., Chai Bao H. and Liu J. (2006). Treatment of oily wastewater by organic-inorganic composite tubular ultrafiltration (UF) membranes. Desalination, 196 (1-3). 1-43 Introduction Lin Y.M., Liu Y. and Tay J.H. (2003). Development and characteristics of phosphorous-accumulating granules in sequencing batch reactor. Applied Microbiology Biotechnology, 62, 430-435. Liu Y., Xu H.L., Yang S.F. and Tay J.H. (2003). Mechanisms and models for anaerobic in upflow anaerobic sludge blanket reactor. Water Research, 37, 661-673. Liu Y., Yang S.F., Tay J-H, Liu Q.S., Qin L. and Li Y. (2004a). Cell hydrophobicity is a triggering force of biogranulation. Enzyme Microbiology Technology, 34, 371-379. Liu Y. and Liu, Q.-S. (2006). Causes and control of filamentous growth in aerobic granular sludge sequencing batch reactors. Biotechnology Advances, 24(1), 115-127. Liu Y-Q. and Tay J-H. (2006). Variable aeration in sequencing batch reactor with aerobic granular sludge. Journal of Biotechnology, 124, 338-346. Madaeni, S. S.; Fane, A. G.; Grohmann, G. S. (1995). Virus removal from water and wastewater using membranes. Journal of Membrane Science, 102 (1-3), 65-75. Martins A. M. P., Heijnen J. J., van Loosdrecht M. C. M. (2003). Effect of feeding pattern and storage on the sludge settleability under aerobic conditions. Water Research, 37(11), 2555-2570. Mavrow V., Chmiel H. and Bélières (2001). Spent process water desalination and organic removal by membranes for water reuse in the food industry. Desalination, 138, 65-74. Mayhew M. and Stephenson T. (1997). Low biomass yield activated sludge: a review. Environmental Technology, 18, 883. Melin T., Jefferson B., Bixio D., Thoeye C., De Wilde W., De koning J., van der Graaf J. And Wontgens T. (2006). Membrane bioreactor technology for wastewater treatment and reuse. Desalination, 178, 271-282. Mohan S.B., Schmid M., Jetten M. and Cole J. (2004). Detection and widespread distribution of the nrfA gene encoding nitrite reduction to ammonia, a short circuit in the biological nitrogen cycle that competes with denitrification. Fems Microbiology Ecology 49 (3), 433-443. Morgenroth E., Sherden T., Van Loosdrecht M.C.M., Heijnen J.J. and Wilderer P.A. (1997). Aerobic granular sludge in a sequencing batch reactor. Water Research, 31 (12), 3191-3194. 1-44 Introduction Mosquera-Corral A., Vázquez-Padín J.R., Arrojo B., Campos J.L. and Méndez R. (2005a). Nitrifying granular sludge in a sequencing batch reactor. In: Aerobic Granular Sludge. Water and Environmental Management Series. IWA Publishing. Munich, (63-70). Mosquera-Corral A., de Kreuk M.K., Heijnen J.J. and van Loosdrecht M.C.M. (2005b). Effects of oxygen concentration on N-removal in an aerobic granular sludge reactor. Water Research, 39 (12), 2676-2686. Mourato D., Behmann H. and McGinn G. (1996). The Zenogem process for municipal sewage treatment plant upgrades. In proceedings of IWSA-EDS Workshop on Membranes in Drinking Water Production, L’Aquila, Italy. Moy B.Y.P., Tay J.H., Toh S.K. Liu Y. and Tay S.T.L. (2002). High organic loading influences the physical characteristics of aerobic sludge granules. Letters in Applied Microbiology, 34, 407-412. Mulder A., van de Graaf A.A., Robertson L.A. y Kuenen J.G. (1995) Anaerobic ammonium oxidation discovered in a denitrifying fluidized bed reactor. FEMS Microbiology Ecology, 16, 177-184. Mulder A. (1992). Anoxic Ammonium Oxidation US patent 427849(5078884). Patente en USA. Ohashi A. and Harada H. (1994). Adhesion strength of biofilms developed in an attached-growth reactor. Water Science and Technology, 29, 10. Painter H.A. and Loveless J.E. (1983). Effect of temperature and pH values on the growth rate constants of nitrifying bacteria in the activated sludge process. Water Research, 17, 237-248. Pavelj N., Hvala N., Kocijan J., Ro M., Ubelj M., Mui G. and Strmnik S. (2001). Experimental design of an optimal phase duration control strategy used in batch biological wastewater treatment. ISA Transactions, 40 (1), 41-56. Peng D., Bernet N., Delgenes J.P. and Moleta R. (1999). Aerobic granular sludge- a case report. Water Research, 33, 890-893. Picioreanu C., Van Loodsdrecht M.C.M. and Heijnen J.J. (2000). Effect of diffusive and convective substrate transport on biofilm structure formation: a two-dimensional modelling study. Biotechnology and Bioengineering, 69, 504-515. Pochana K. and Keller J. (1999). Study of factors affecting simultaneous nitrification and denitrification (SND). Water Science and Technology, 39 (6), 61-8. 1-45 Introduction Poth M. and Focht D. (1985). 15N kinetic analysis of N2O production by Nitrosomonas europaea: an examination of nitrifier denitrification. Applied and Environmental Microbiology, 49 (5), 1134-1141. Qin L., Tay J-H and Liu Y. (2004a). Selection pressure is a driving force of aerobic granulation in sequencing batch reactors. Process Biochemistry, 39, 579-584. Qin L. Liu Y. and Tay J-H (2004b). Effect of settling time on aerobic granulation in sequencing batch reactor. Biochemistry Engineering Journal, 21, 47-52. Ramadori R., Iaconi Di C., López A. and Passino R. (2006). An innovative technology based on aerobic granular biomass for treating municipal and/or industrial wastewater with low environmental impact. Water Science and Technology, 53 (12), 321-329. Räsänen E., Nyström M., Sahlstein J. and Tossavainen O. (2002). Purification and regeneration of diluted caustic and acid washing solutions by membrane filtration. Desalination, 149, 185-190. Schleypen P., Michel I. and Siewert H.E. (1997). Sequencing batch reactors with continuous inflow for small communities in rural areas in Bavaria. Water Science and Technology, 35 (1), 269-276. Schmidt J.E. and Ahring B.K. (1996). Granular sludge formation in upflow anaerobic sludge blanket (UASB) reactors.Biotechnology and Bioengineering, 49, 229-246. Schmid M., Twachtmann U., Klein M., Strous M., Juretschko S., Jetten M., Metzger J, Schleifer K.H. y Wagner M. (2000). Molecular evidence for genus level diversity of bacteria capable of catalyzing anaerobic ammonium oxidation. Systematic and Applied Microbiology, 23, 93-106. Schmidt M., Schmitz-Esser S., Jetten M. and Wagner M. (2001). 16S-23rDNA intergenic spacer and 23S rDNA of anaerobic ammonium-oxidizing bacteria: implications for phylogeny and in situ detection. Environmental. Microbiology, 3 (7), 450-9. Schmidt I., Hermelink C., van de Pas-Schoonen K., Strous M., Camp H.J., Kuenen J.G.and Jetten M.S.M. (2002). Anaerobic ammonia oxidation in the presence of nitrogen oxides (NOx) by two different lithotrophs. Applied Enviromental Microbiology, 68 (11), 5351-5357. Schmid M., Walsh K., Webb R. Rijpstra WIC, van de Pas-Schoonen K.T., Verbruggen M.J., Hill T., Moffett B., Fuerst J., Schouten S., Sinninghe Damste JS, Harris J., Shaw P.ñ, Jetten MSM and Strous M. (2003). 1-46 Introduction Candidatus “Scalindua brodae”, sp nov., Candidatus “Scanlindua wagneri”, sp nov., two species of anaerobic ammonium oxidizing bacteria. Systematic and Applied Microbiology, 26, 529-538. Schwarzenbeck N., Erley R. and Wilderer P.A. (2004). Aerobic granular sludge in an SBR-system treating wastewater rich in particulate matter. Water Science and Technology, 49 (11-12), 41-46. Schwarzenbeck N. and Wilderer P.A. (2005). Treatment of food industry effluents in a granular sludge SBR. In: Aerobic Granular Sludge. Water and Environmental Management Series. IWA Publishing. Munich, (95-102). Schulthess R., Wild D. and Gujer W. (1994). Nitric and nitrous oxide from denitrifying activated sludge at low oxygen concentration. Water Science and Technology, 30 (6), 123-132. Shaw L.J., Nicol G.W., Smith Z., Fear J., Prosser J. and Baggs E.M. (2006). Nitrosospira spp. can produce nitrous oxide via a nitrifier denitrification pathway. Applied and Environmental Microbiology, 8 (2), 214-222. Shin H. S., Lim K.H. and Park H. S. (1992). Effect of shear stress on granulation in oxygen aerobic upflow sludge reactors. Water Science and Technology, 26, 601-605. Steinbuchel A. (1996). PHB and other polyhydroxyalkanoic acids. In: HJ Rehm, G.Reed. Biotechnology. Products of primary metabolism. Weinheim: Verlag Chemie. 405-464. Strenstrom M.K. and Poduska R.A. (1980). The effect of dissolved oxygen concentration on nitrification. Water Research, 14, 643-649. Strous M., van Gerven E., Kuenen J.G. y Jetten M. (1997a). Ammonium removal from concentrated waste streams with the Anaerobic Ammonium Oxidation (anammox) process in different reactor configurations. Water Research, 31, 1955-1962. Strous M., van Gerven E., Kuenen J.G. y Jetten M. (1997b). Effects of aerobic and microaerobic conditions on anaerobic ammonium-oxidizing (anammox) sludge. Applied and Environmental Microbiology, 63, 2446-2448. Strous M., Heijnen J.J., Kuenen J.G. y Jetten M. (1998). The sequencing batch reactor as a powerful tool for the study of slowly growing anaerobic ammonium-oxidizing microorganisms. Applied Microbiology and Biotechnology, 50, 589-596. 1-47 Introduction Strous M., Kuenen J.G. y Jetten M. (1999). Key physiological parameters of anaerobic ammonium oxidation. Applied Microbiology and Biotechnology, 65, 3248-3250. Strous M., Kuenen J.G., Fuerest J.A., Wagner M. and Jetten M.S.M. (2002). The Anammox case- A new experimental manifesto for microbiological ecophysiology. Antonie van Leuwenhoek. 81, 693-702. Stüven R. and Bock E. (2001). Nitrification and denitrification as a source for NO and NO2 production in high-strength wastewater. Water Research, 35 (8), 1905-1914. Suthersand S. and Ganczarczyk J.J. (1986). Inhibition of nitrite oxidation during nitrification. Some observations. Water Research Journal, 21 (2), 257-266. Sutka R.L., Ostrom N.E., Ostrom P.H., Breznak J.A. , Gandhi H., Pitt A.J. and Li F. (2006). Distinguishing nitrous oxide production from nitrification and denitrification on the basis of isotopomer abundances. Applied and Environmental Microbiology, 72(1), 638-644. Tac-Hyun B., Sung-soo H. Tac-Mon T. (2003). Membrane sequencing batch reactor system for the treatment of dairy industry wastewater. Process Biochemistry, 39, 221-231. Tay J.-H., Liu Q.-S. and Liu Y. (2001a). The role of cellular polysaccharides in the formation and stability of aerobic granules. Letters of Applied Microbiology, 33, 222–226. Tay J.-H., Liu Q.-S. and Liu Y. (2001b). The effects of shear force on the formation, structure and metabolism of aerobic granules. Applied Microbiology and Biotechnology, 57, 227-233. Tay J-H, Liu Q-S y Liu Y. (2001c). Microscopic observation of aerobic granulation in sequential aerobic sludge blanket reactor. Journal of Applied Microbiology, 91, 168-175. Tay J.-H., Liu Q.-S. y Liu Y. (2002a). Aerobic granulation in sequential sludge blanket reactor. Water Science and Technology, 46(4-5), 13-18. Tay J-H, Liu Q-S and Liu Y. (2002b). Hydraulic selection pressure-induced nitrifying granulation in sequencing batch reactors. Applied Microbiology and Biotechnology, 59, 332-337. Tay J-H., Pand S., He Y.X. and Tay S.T.L. (2003a). Effect of organic loading rate on aerobic granulation: Part II. Characteristics of aerobic granules. Journal Environmental Engineering, 130 (10), 1102-1109. 2-4 Chapter 2 c. Ferroin indicator solution: 1.485 g of C18H8N2·H2O (phenanthroline monohydrate) and 0.695 g of SO4Fe·7H2O are dissolved in 100 mL of distilled water. d. Standard potassium dichromate solution 0.05 N. 1.226 g of K2Cr2O7, previously dried at 105ºC for 2 hours, are dissolved in 500 mL of distilled water. e. Standard ferrous ammonium sulphate titrant (FAS) 0.035 N: 13.72 g of Fe(NH)4(SO)2·6H2O are dissolved in distilled water. Then, 20 ml of concentrated H2SO4 are added and, finally, the solution is cooled and diluted to 1000 mL Determination procedure This procedure is applicable to samples with COD concentrations between 90-900 mg/L. Place 2.5 mL of sample in 10-mL Pirex tubes. Add 1.5 mL of digestion solution and 3.5 mL of sulphuric acid reagent slowly on the wall of the tube slightly inclined (to avoid mixing). A blank sample using distilled water is prepared in the same way. This blank acts as “reference”, representing the COD of the distilled water. After being sealed with Teflon and tightly capped, the tubes are finally mixed completely and placed in the block digester (HACH 16500-100) preheated to 150ºC. The duration of the digestion period is 2 h. After digestion, the tubes are cooled to room temperature. Then, the content of the tubes is transferred to a beaker and, once added 1-2 drops of ferroin indicator, the solution is titrated under rapid stirring with standard FAS. The FAS solution is standardised daily as follows: Put 5 mL of distilled water into a small beaker. Add 3.5 mL of sulphuric acid reagent. Cool to room temperature and add 5 mL of standard potassium dichromate solution (0.05 N). Add 1-2 drops of ferroin indicator and titrate with FAS titrant. The end-point is a sharp colour change from blue-green to reddish brown. Molarity of FAS solution is calculated with the following equation: fas fas V 0.055 M × = [2.1] where: 2-5 Materials and Methods M fas: molarity of FAS (mol/L), and V fas: volume of FAS consumed in the titration (mL). The COD is calculated with the following equation: () V 8,000MBA COD fas × × − = [2.2] where: COD: Chemical Oxygen Demand (mg O2/L), A: mL of FAS consumed by the blank, B: mL of FAS consumed by the sample, Mfas: molarity of FAS (mol/L), and 8,000: milliequivalent weight of oxygen x 1,000 mL/L. 2.1.2. Total Organic Carbon (TOC) Organic carbon in liquid samples may include a variety of organic compounds in different oxidation states. Total Organic Carbon (TOC) is a more convenient and direct expression of total organic content than COD, but does not provide the same information. Unlike COD, TOC is independent of the oxidation state of the organic matter and does not measure other organically bound elements, such as nitrogen and hydrogen, and inorganics that can contribute to the oxygen demand measured by COD (APHA-AWWA-WPCF, 1999). To determine the quantity of organically bound carbon, the organic molecules must be broken down and converted to a single carbon molecular form that can be measured quantitatively. The TOC concentration was determined by a Shimadzu analyzer (TOC-5000) as the difference between the Total Carbon (TC) and the Inorganic Carbon (IC) concentration. The instrument is connected to an automated sampler (Shimadzu, ASI-5000-S). TC is determined from the amount of CO2 produced during the combustion of the sample at 680°C, using platinum immobilised over alumina spheres as catalyst. The IC is obtained from the CO2 produced in the chemical decomposition of the sample with H3PO4 (25%) at room temperature. The CO2 produced is optically measured with a nondispersive infrarred analyzer (NDIR) after being cooled and dried. High purity air is used as carrier gas with a 2-6 Chapter 2 flow of 150 mL/min. 4-points calibration curve in the range of 0-1 g C/L, using potassium phthalate as standard for TC and a mixture of sodium carbonate and bicarbonate (Na2CO3/NaHCO3, 3:4 w/w) for IC, is used for the quantification (Figure 2.1). TC y = 0.0199x - 1.3652 R2 = 0.9999 IC y = 0.0255x - 3.943 R2 = 0.9998 0 200 400 600 800 1000 1200 0 20000 40000 60000 Area C (mg/L) Figure 2.1. Calibration curve 2.1.3. Volatile Fatty Acids (VFA) Volatile Fatty Acids (VFA), acetic, propionic, i-butiric, n-butiric, i-valeric and n-valeric, are intermediate products of the anaerobic digestion. A VFA accumulation reflects a kinetic disequilibrium between the acids producers and the acids consumers (Switzembaum et al., 1990) and it is an indicator of process destabilization. VFA are determined by gas chromatography (HP, 5890A) equipped with a Flame Ionization Detector (FID) and an automatic injector (HP, 7673A). The determination is performed in a glass column (3 m long and 2 mm of internal diameter) filled with Chromosorb WAW (mesh 100/120) impregnated with NPGA (25%) and H3PO4 (2%). The column, injector and detector temperatures are 105, 260 and 280°C, respectively. Gas N2, previously saturated with formic acid before entering into the injector, is used as carrier gas with a flow of 24 mL/min. Air and H2 are used as auxiliary gases with flows of 400 and 30 mL/min, 2-7 Materials and Methods respectively. VFA, after being separated in the column according to their molecular weights, are burnt in a H2-air flame and finally measured in the FID at 280°C. The quantification of the sample is made with a 6-8 point calibration curve for each acid in the range of 0-1 g/L, using pivalic acid as internal standard (Figure 2.2). y = 6.5249x + 0.004 R2 = 0.9998 0.00 0.20 0.40 0.60 0.80 1.00 1.20 0.00 0.05 0.10 0.15 0.20 Area Acetic acid (g/L) Figure 2.2. Calibration curve for the acetic acid. 2.1.4. Nitrogen In waters and wastewaters, the forms of nitrogen of greatest interest are, in order of decreasing oxidation state, nitrate, nitrite, ammonia and organic nitrogen. All these forms, as well as nitrogen gas (N2), are biochemically interconvertible and they are the components of the nitrogen cycle. Organic nitrogen is defined functionally as the organically bound nitrogen in the trinegative oxidation state, but it does no include all organic nitrogen compounds. Analytically, organic nitrogen and ammonia can be determined together and have been referred to as “Total Kjeldahl Nitrogen” (TKN), a term that reflects the technique used in their determination. Total inorganic nitrogen (IN) is the sum of the nitrate and nitrite forms. 2-8 Chapter 2 Total (TN), Inorganic (IN) and Total Kjeldhal Nitrogen (TKN) TKN was determined in a total organic nitrogen analyzer (Rosemount- Dohrmann DN-1900) equipped with a quimioluminiscence detector with two channels. One channel determines the Total Nitrogen (TN), by oxidation at high temperature, and the other determines the Inorganic Nitrogen (IN), by a chemical reduction. TKN is determined as the difference between TN and IN. All the nitrogen present in the water is catalytically oxidised to nitrous oxide (NO). The process for TN determination occurs in two steps. The first step is a catalytic (Cu as catalyst) oxidation in the combustion tube at 850°C and with pure oxygen (1 atm) as carrier gas. The second one is the chemical reduction of residual NO2 with H2SO4 at 80ºC and catalyzed by VaCl3. For the IN determination, only the second step (chemical reduction) is used. The NO obtained in the two steps is dried and forced to react with O3 producing an unstable excited state NO2*. The change back of this oxide to its fundamental state releases a proton, from which the determination of TN and IN is carried out by quimioluminiscence, using a multiplicator tube. The instrument is calibrated with a certified standard solution (KNO3, 20 mg N/L) using a response factor method. Ammonia nitrogen Ammonia nitrogen is determined by a colorimetric method (Wheatherburn, 1967). It is based on the reaction of NH3 with HClO and phenol, forming a strong-blue compound (indophenol) which can be colorimetrically determined using a spectrophotometer (Shimadzu UV-1603, UV-Visible) at 635 nm. Reagents preparation a. Solution 1: Phenol-nitroprusiate: 15 g of phenol and 0.05 g of sodium nitroprusiate are added to 250 mL of buffer solution. The buffer solution was prepared adding 30 g of Na3PO4·12H2O, 30 g Na3C6H5O7·2H2O and 3 g EDTA per liter, adjusted to pH 12. b. Solution 2: Hipochloride: 15 mL of commercial bleach are mixed with 200 mL of NaOH 1 N and filled up to 500 mL with distilled water. 2-9 Materials and Methods Determination procedure Place 2.5 mL of sample (diluted if necessary to get a maximum concentration of 1 mg NH4+-N/L) and add, 1.0 and 1.5 mL of solution 1 and 2, respectively. After waiting 45 min at room temperature, the concentration of NH4+-N is measured in a spectrophotometer at 635 nm. The quantification is done with a 5-7 points calibration curve in the range of 0-1 mg NH4+-N/L, using NH4Cl as standard (Figure 2.3). y = 0.8116x + 0.103 R2 = 0.9994 0.00 0.20 0.40 0.60 0.80 1.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 Abs (635 nm) NH4+-N (mg/L) Figure 2.3. Calibration curve Nitrite Nitrite concentration in wastewater is determined following the method 4500-NO2--B described in Standard Methods for the Examination of Water and Wastewater (APHA-AWWA-WPCF, 1999). Nitrite is determined through the formation of a reddish purple azo dye produced at pH 2.0-2.5 by coupling diazotized sulphanilamide with N-(1- napththyl)-ethylenediamine dihydrochloride (NED dihydrochloride). 2-10 Chapter 2 Reagents preparation a. Sulphanilamide: 10 g of sulphanilamide are dissolved in 100 mL of concentrated HCl and 600 mL of distilled water. After cooling, the volume is filled up to 1 L with distilled water. b. NED: 0.5 g of NED are dissolved in 500 mL of distilled water. Determination procedure To 5 mL of sample (diluted if necessary to fit the concentration range of the method), 0.1 mL of each solution (sulphanilamide and NED) are added. After waiting 20 min for colour stabilisation, the sample is measured in a spectrophotometer (Shimadzu UV-1603) at 543 nm. The quantification is done with 6-8 points calibration curve in the range of 0-0.30 mg NO2--N/L, using NaNO2 as standard (Figure 2.4). y = 0.2682x - 0.0015 R2 = 0.9999 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.00 0.20 0.40 0.60 0.80 1.00 1.20 Abs (543 nm) NO2- -N (mg/L) Figure 2.4. Calibration curve Nitrate Nitrate concentration in wastewater is determined following the method 4500-NO3--B described in Standard Methods for the Examination of Water and Wastewater (APHA-AWWA-WPCF, 1999). 2-11 Materials and Methods Measurement of UV absorption at 220 nm enables rapid determination of NO3- ions. Because dissolved organic matter also may absorb at 220 nm and NO3- does not absorb at 275 nm, a second measurement at 275 nm is used to correct the NO3- value. Determination procedure Place 5 mL of sample (diluted if necessary to get a maximum concentration of NO3--N of 2.5 mg/L) and add 0.1 mL of HCl 1N. Afterwards, the absorbance at 220 and 275 nm is measured in a spectrophotometer (Shimadzu UV-1603). The absorbance related to nitrate is obtained by subtracting two times the absorbance reading at 275 nm from the reading at 220 nm. The quantification is done with a 6-8 points calibration curve in the range of 0-2.50 mg NO3--N/L, using KNO3 as standard (Figure 2.5). y = 3.7256x - 0.0199 R2 = 0.9955 0.00 0.50 1.00 1.50 2.00 2.50 0.00 0.20 0.40 0.60 0.80 Abs (220 - 2·275 nm) NO3--N (mg/L) Figure 2.5. Calibration curve 2.1.5. Inorganic anions: NO2-, NO3-, Cl-; PO43- and SO42- Nitrite (NO2-), nitrate (NO3-), chloride (Cl-), phosphate (PO43-) and sulphate (SO42-) are determined simultaneously by Waters Capillary Ion Analyzer (CIA). A solution of sodium cromate (0.005 mol/L) is used as electrolyte (Vilas-Cruz et al., 1994). Plus, an electro-osmotic modifier (50 mL/L) CIA-PakTM OFM Anion BT 2-12 Chapter 2 Waters (Ewing et al., 1989; Heiger, 1992) is also added. The sample is forced to migrate through a capillary (melting silica covered with poliimida, 60 cm long and 75 µm of internal diameter) kept at 25°C by the application of an electric current. Depending on the ratio charge/mass of the ion, the migrating time is different. A hydrostatic injection (10 cm height for 30 seconds) and an indirect detection (UV, 254 nm, 20 kV, 16-22 µA) are used. 4-6 calibration points for each ion in the range of 3-100 mg·L-1 are daily used for the quantification of the samples (Figure 2.6). Figure 2.6. Typical electropherogram 2.1.6. Other control parameters pH pH is one of the key parameters used in wastewater treatment, since its control is important to maintain the biological activity of the microorganisms involved in the treatment process. pH measurements were performed with an electrode (Crison Instruments, S.A., 52-03) equipped with an automatic compensatory temperature device (Crison Instruments, S.A., 21-910-01) and connected to a measure instrument (pH/mV). The sensibility of the instrument is ± 1 mV, corresponding to 0.01 pH units. The electrode is calibrated at room temperature with two standard buffer solutions of pH 7.02 and 4.00. 2-13 Materials and Methods Dissolved oxygen (DO) A dissolved oxygen probe (AQUALITYC, model OXI-921) connected to a meter (M-Design Instruments TM-3659) was used to control DO concentration in the reactor. Temperature A probe (Thermometer checktemp1, model Celsius HI98509 HANNA instruments) was used to determine the temperature. 2.2. Solid phase 2.2.1. Total and Suspended Solids Solids present in water can be organic or inorganic. Total Solids (TS), Total Suspended Solids (TSS), Volatile Solids (VS) and Volatile Suspended Solids (VSS) are determined following the methods 2540B, 2540D and 2540E, respectively, described in Standard Methods for the Examination of Water and Wastewater (APHA-AWWA-WPCF, 1999). Determination procedure TS are determined weighing a selected (in order to yield a residue between 2.5 and 200 mg) well-mixed sample volume in a previously clean (heated to 103- 105ºC for 2 h) dish after being evaporated at 103-105ºC until constant weight. The increase in weight over that of the empty dish represents the total solids in the initial volume of sample. For the determination of TSS, a selected (in order to yield a residue between 2.5 and 200 mg) well-mixed sample volume is filtered through a weighed glassfiber filter (Whatman, GF/C, 4.7 cm of diameter, 1.2 µm of pore size) and the residue retained on the filter is dried to a constant weight (2h) at 103-105ºC. The increase in weight of the filter represents the total suspended solids. To determine the volatile solids (VS or VSS), the residue from method 2540B and 2540D is burnt to constant weight at 550ºC during half an hour. The weight lost during ignition corresponds to the volatile solids. Since only a small amount of inorganic salts are decomposed and volatilised at that temperature. 2-20 Chapter 2 2. Filtration and incubation For the bacteria determination, the samples were filtered in triplicate using membranes (of cellulose nitrate) of 47 mm of diameter with a pore size of 0.45 µm (Sartorius) (Figure 2.9), An amount of 100 mL of sample was filtered by means of a vacuum system using sterile material and a steel support, which was also sterilized. After the filtration, the filter was placed on the Petri plates containing the media. The filter was incubated in a heater for 24 h at 44 ºC. 3. Enumeration of the colonies During the permanence time in the heater, with the ideal media and temperature, each single bacteria present in the sample multiplies forming a colony, which results visible. The number of colonies formed on the plate is counted. For the determination of faecal coliform, all blue coulored colonies were counted. The faecal coliforms were directly counted (blue colonies); however, Escherichia Coli bacteria distinguished from faecal coliforms using a fluorescence lamp (wood lamp). All the results were expressed as Coliform Forming Units (CFU) per 100 millilitres of sample (Figure 2.10). 2-21 Materials and Methods Figure 2.9. Membrane filtration device. Figure 2.10. Enumeration of the colonies. 2-22 Chapter 2 2.4.2. Identification of bacteria populations by Fluorescent in Situ Hybridisation The abundance of the different populations of microorganisms present in the sludge samples of the reactors was researched by Fluorescent In Situ Hybridization (FISH). Figure 2.11 shows the phylogenetic tree reflecting the relationships between different bacteria: ammonia-oxidizing (AOB) and nitriteoxidizing bacteria (NOB). The phylogenetic tree for Plantomycetales and other reference organisms is shown in Figure 2.12. BET42a GAM42a ALF1b NEU NIT NTSPA •Ammonia oxidizing B. •Nitrite oxidizing B. BET42a GAM42a ALF1b NEU NIT NTSPA •Ammonia oxidizing B. •Nitrite oxidizing B. Figure 2.11. 16S rRNA-based tree showing the phylogenetic affiliation of AOB (green) and NOB (red). The scale bar indicates 0.1 estimated change per nucleotide. 2-23 Materials and Methods Figure 2.12. 16S rRNA-based tree showing the phylogenetic affiliation of Plantomycetales. The scale bar indicates 0.1 estimated change per nucleotide. In this technique specific regions in 23S or 16S rRNA are targetted with fluorescently labelled probes. If the corresponding domain, phylum, genus or species is present, the probe hybridises to the target sequence and can later be detected microscopically. According to Amann (1995) a typical FISH protocol includes four steps (Figure 2.13): the fixation and permeabilisation of the sample; hybridisation of the target sequence to the probe; washing steps to remove unbound probe; and the detection of labelled cells by microscopy or flow cytometry. The method followed in this study is detailed in Amann (Amann et al., 1990). During hybridization the cells are exposed to elevated temperatures, detergents and osmotic gradients. Thus fixation of the cells is essential in order to maintain the morphological integrity of the cells. Fixation of cells with glutaraldehide results in considerable autofluorescence of the specimen. 2-24 Chapter 2 Autofluorescence is minimized by fixation in freshly prepared (not older than 24 h) 4% paraformaldehyde solution in PBS. After fixation, the cells are immobilized on a microscopic slide and used for hybridazation with 16S rDNA probes. In order to avoid non-specific binding of the rDNA probes, the hybridisation is done at stringent conditions (46 ºC, 0-65% formamide) and specimens are washed with wash buffer (48ºC). The target organisms can be detected by the characteristic fluorescence. Figure 2.13. Typical FISH protocol The dyes used to detect the hybridised rRNA were fluorescein (λexc. = 495nm, λem. = 519nm) and carbocyanine (λexc. = 558nm, λem. = 670nm). To 2-25 Materials and Methods visualise all cells in a sample the stain DAPI was used (λexc. = 359nm, λem. = 461nm). Its application can provide insight into the existence of archaeo-bacteria and eukaryotes, like e.g. protozoa. For analysis of the slides an epifluorescence microscope (Axioskop 2 plus, Zeiss) in combination with a digital camera (Coolsnap, Roper Scientific Photometrics) was used. The probes applied in this study are listed in Table 2.2. The three probes for the domain of eubacteria (EUB338, EUB338II and EUB338III) were applied together in all samples to get an impression of the relative abundance of the microorganisms detected by more specific probes. In comparison with DAPI they provided evidence of non-eubacteria present in the sample. Probe PLA46 was used in combination with Amx820 to eventually provide evidence of the existence of Anammox bacteria (or other planctomycetales) other than those covered by Amx 820. In some cases probe Nso 1225 was combined with NEU 653. Besides NEU653 and Ntspa712 were used simultaneously for the characterisation of the structure of the nitrifying population. For further discussion it has to be kept in mind that samples can never be 100% representative. Thus the fact that no bacteria of a certain kind were present in the sample can always be attributed to irrepresentative sampling as well. Still it was tried to keep this error small. It has to be noted that when the term Anammox organisms, ammoniumoxidisers or nitrite-oxidisers is used, it refers to those staining with the corresponding probes, i.e. Amx 820, NEU 653 and Ntspa 712, respectively. The denomination EUB refers to all three EUB-probes. 2-26 Chapter 2 Probename Target site 16S Probe sequence (5’→3’) % Fornamide in situ Target organisms Ref. EUB338 338-355 GCT GCC TCC CGT AGG AGT 35 Bacteria domain Amann et al., 1990 EUB 338- II GCA GCC ACC CGT AGG TGT 60 Bacterial lineages not covered by probe EUB338 Daims et al., 1999 EUB 338- III GCT GCC ACC CGT AGG TGT 60 Bacterial lineages not covered by probe EUB338 and EUB338II Daims et al., 1999 PLA46 46-63 GAC TTG CAT GCC TAA TCC 20 Planctomycetes Neef et al., 1998 NEU653 (& competitor) 653-670 CCC CTC TGC TGC ACT CTA TTC CAT CCC CCT CTG CCG 40 Most halophilic and halotolerant Nitrosomonas spp. Wagner et al., 1995 Nso1225 1225-1244 CGC CAT TGT ATT ACG TGT GA 35 Ammonio-oxidizing- β- Proteobacteria Mobarry et al., 1996 Nsv443 444-462 CCG TGA CCG TTT CGT TCC G 40 Nitrosolobus multiformis, Nitrosospira briensis, and Nitrosovibrio tenuis. Mobarry et al., 1996 NIT1035 (& competitor) CCT GTG CTC CAT GCT CCG CCT GTG CTC CAG GCT CCG 40 Nitrobacter spp. Wagner et al. ,1996 Ntspa712 (& competitor) 712-732 CGC CTT CGC CAC CGG CCT TCC CGC CTT CGC CAC CGG GTT CC 35 Most members of phylum Nitrospira Daims et al., 2001 AMX820 820-841 AAA ACC CCT CTA CTT AGT GCC C 35 Candidatus “Brocardia anammoxidans” Schmid, 2001 Alf1b 19-35 CGT TCG YTC TGA GCC AG 20 Alphaproteobacteria, some Deltaproteobacteria, Spirochaetes Manz et al., 1992 Gam42a 1027-1043 GCC TTC CCA CAT CGT TT 35 Gammaproteobacteria Manz et al., 1992 NSm156 156-174 TAT TAG CAC ATC TTT CGA T 5 Nitrosomonas spp., Nitrosococcus mobilis Mobarry et al.,1996 Bet 42a 1027-1043 GCC TTC CCA CTT CGT TT 35 Betaproteobacteria Manz et al., 1992 Table 2.2. Probes used for fluorescent in situ hybridisation and the formamide concentration used during hybridisation 2-27 Materials and Methods 2.5. References Amann, R. I., B. J. Binder, R. J. Olson, S. W. Chisholm, R. Devereux, and D. A. Stahl. (1990). Combination of 16S rRNA-targeted oligonucleotide probes with flowcytometry for analyzing mixed microbial populations. Applied and Environmental Microbiology, 56, 1919–1925. Amann R.I. (1995). In situ identification of micro-organisms by whole-cell hybridization with RNA-targeted nucleic acid probles, p.1-15. In A.D.L.: Akkerman, J.D., van Elsas and F.J. de Brujin (ed), molecular microbial ecology manual. Kluwer Academic Publisher, Dordrecht, The Netherlands. APHA-AWWA-WPCF. (1999). Standard Methods for the examination of water and wastewater. 20th Edition. Clesceri, L.S., Greenberg, A.E. & Eaton, A.D. (eds.). Beun J.J., van Loosdrecht M.C.M. and Heijnen J.J. (2002). Aerobic granulation in a sequencing batch airlift reactor. Water Research, 36, 702-712. Daims H., Brühl A., Amann R., Schleifer K.-H. and Wagner M. (1999). The domain-specific probe EUB338 is insufficient for the detection of all Bacteria: Development and evaluation of a more comprehensive probe set. Systematic and Applied Microbiology, 22, 434-444. Daims H., Nielsen J. L., Nielsen P. H., Schleifer K. H. and Wagner M. (2001). In Situ characterization of Nitrospira-like nitrite-oxidizing bacteria active in wastewater treatment plants. Applied and Environmental Microbiology, 67, 5273-5284. de Kreuk M.K., McSwain B.S., Bathe S., Tay S.T.L., Schwarzenbeck and Wilderer P.A. (2005). Discussion outcomes. Ede. In: Aerobic Granular Sludge. Water and Environmental Management Series. IWA Publishing. Munich, (165-169). Ewing, A.G., Wallengford, R.A. and Oleferowicz, T.M. (1989). Capillary electrophoresis. Analytical Chemistry, 61 (4), 292A-303A. Heiger, D.N. (1992). High performance capillary electrophoresis: an introduction. Hewlett Packard GmbH, Waldbronn, Germany. Isra-Cnr (1994). “Metodi analitici per le Acque”. 2-28 Chapter 2 Jeison D. and Chamy R. (1998). Novel technique for measuring the size distribution of granules from anaerobic reactors for wastewater treatment. Biotechnology Techniques, 12 (9), 659-662. Manz W., Amann R., Ludwig W., Wagner M. and Schleifer K.-H. (1992). Phylogenetic oligodeoxynucleotide probes for the major subclasses of Proteobacteria: problems and solutions. Systematic and Applied Microbiology, 15, 593 - 600. Mobarry, B., M. Wagner, V. Urbain, B. Rittmann, and D. Stahl. (1996). Phylogenetic probes for analyzing abundance and spatial organization of nitrifying bacteria. Applied and Environmental Microbiology, 62, 2156–2162. Neef A., Amann R., Schlesner H. and Schleifer K.-H. (1998). Monitoring a widespread bacterial group: in situ detection of planctomycetes with 16S rRNA-targeted probes. Microbiology, 144, 3257-3266. Schmid M., Schmitz-Esser S., Jetten M. and Wagner M. (2001). 16S-23rDNA intergenic spacer and 23S rDNA of anaerobic ammonium-oxidizing bacteria: implications for phylogeny and in situ detection. Environmental Microbiology, 3 (7), 450-459. Soto, M., Veiga, M.C., Méndez, R. and Lema, J.M. (1989). Semi-micro COD determination method for high salinity wastewater. Environmental and Technology Letters, 10 (5), 541-548. Switzembaum, M.S., Giraldo-Gómez, E. and Hickey, R.F. (1990). Monitoring of the anaerobic methane fermentation process. Enzyme and Microbial Technoogy, 12 (10), 722-730. Schwarzenbeck N., Erley R. and Wilderer P.A. (2004). Aerobic granular sludge in an SBR-system treating wastewater rich in particulate matter. Water Science and Technology, 49 (11-12), 41-46. Tijhuis L., van Benthum WAJ, van Loosdrecht MCM and Heijnen J.J. (1994). Solids retention time in spherical biofilms in a biofilm airlift suspension reactor. Biotechnology Bioengineering, 44, 867-879. Vilas-Cruz, M., Gómez, J., Méndez, R. and Lema, J.M. (1994). Determinación simultánea de NO2- y NO3- en aguas residuales por electroforesis capilar. Proc. 2-29 Materials and Methods of the III International Symposium of Analytical Methodology for the Environment. Vol. II, 1-50. Barcelona, 23-24 March. Wagner M., Rath G., Koops H.P., Flood J. and Amann R. (1996). In situ analysis of nitrifying bacteria in sewage treatment plants. Water Science and Technology, 34, 237-244 Wheatherburn M.W. (1967). Phenol-hypochlorite reaction for determination of ammonia. Analytical Chemistry, 28, 971-974. 3-6 Chapter 3 PLC O2/N2 INFLUENT EFLUENT (1) (2) (3) (5) (4) (6) A) B) Figure 3.1. A)Experimental set up: (1) Feeding tank; (2) Feeding pump; (3) Effluent pump; (4) Effluent tank (5); Air and N2 valves; (6) PLC. B) Picture of the reactor. 3-7 Aerobic granulation with industrial wastewater in Sequencing Batch Reactors 3.3.2. Inocula Both reactors were inoculated with sludge collected from the industrial SBR. This sludge was the typical flocculent activated sludge with a fluffy, irregular and loose morphology and relative abundance of filamentous microorganisms. Settling properties of this sludge were: SVI of 200 mL/g VSS, and ZSV of 0.3 m/h. 3.3.3. Feeding media Two different feedings were used during the studies with both SBRs: a synthetic wastewater and an industrial wastewater from a laboratory for analysis of dairy products located near A Coruña, Spain (Table 3.1). The synthetic wastewater contained soluble COD as the sole organic matter fraction and the industrial wastewater contained both soluble and particulated COD. The composition of the synthetic wastewater (SW) fed to reactor R1 was according to Beun et al. (1999) and the trace solution to Smolders et al. (1995). The industrial wastewater was the same as that used to feed the industrial scale SBR of 28 m3 and was previously treated in an anaerobic filter in order to reduce the organic matter fraction (Figure 3.2). Additional information about the generation of the industrial wastewater and of the treatment plant can be found elsewhere (Garrido et al. 2001; Omil et al. 2003; Arrojo et al., 2003; Fernández et al., 2004). Table 3.1. Composition of wastewater of the laboratory for analysis of dairy products (IW) and the synthetic wastewater (SW) used to feed the SBRs. Parameters Concentration (mg/L) IW Concentration (mg/L) SW CODt 500-3000 500 CODs 300-1500 500 Total nitrogen 50-200 25 TSS 200-1200 0 VSS 100-1000 0 VFA 100-500 6321 Phosphate 20-60 23 (1 acetate concentration in the SW) 3-8 Chapter 3 M Blower PLC Bio g as Influent SBR ANAEROBIC FILTER STORAGE TANK EQUALISATION BASIN Effluent Heater T < 60ºC Heat exchanger TIC A) B) Figure 3.2. Schematic layout of the plant (A) and picture of the industrial wastewater plant (B). 3-9 Aerobic granulation with industrial wastewater in Sequencing Batch Reactors 3.3.4. Strategy of operation The operation of R1 and R2, summarized in Table 3.2, did not commence simultaneously, thus day 1 corresponds in this study to the day when R1 was fed for the first time with the synthetic wastewater for 27 days. On day 27 the synthetic medium was replaced stepwise with a fraction of the industrial wastewater, maintaining the soluble COD concentration nearly constant. After day 48, it was fed exclusively with the industrial wastewater. Operation of R2 started 50 days later and was directly fed with the industrial wastewater. The strategy of operation was similar in both systems from day 50 on. Table 3.2. Main operational stages of the two SBRs which were performed during the study. SW: Synthetic Wastewater; IW: Industrial Wastewater. 1 Volume of SW and IW which were fed to R1. Day R1 R2 1 Start up SW -------- 27 0.75 : 0.25 1 -------- 34 0.50: 0.50 1 -------- 41 0.25: 0.75 1 -------- 48 IW -------- 50 -------- Start up IW 83 Anoxic period = 10 min -------- 133 Anoxic period = 30 min -------- 188 Increase OLR Withdrawal time =1 min Withdrawal time =1/2 min Constant OLR Withdrawal time =1 min Withdrawal time =3 min SW Table 3.2 shows some of the main operational stages and changes in the strategy of operation. Both systems were inoculated with sludge collected from the industrial SBR and were operated in cycles of 3 hours with an exchange 3-10 Chapter 3 volume of 50%. Every cycle comprehended a feeding period of 3 min, a reaction period under anoxic and aerobic conditions of 171 min, a settling period of 1 min, an effluent withdrawal period comprehended between 0.5 and 3 min and an idle period between 2 and 4.5 min (Figure 3.3A). On day 83 an anoxic period of 10 minutes was included in the cycle of R1 and from day 133 on, this increased to 30 minutes until the end of operation of the reactor (day 320) (Figure 3.3B). Especial attention was paid to two experiments during this research: the study of the influence of withdrawal time and of the influence of TSS in the influent over the efficiency of the reactor. The influence of withdrawal period was studied by modifying its length from 3 min to 1 min and to 1/2 min in two kind of experiments: the first using different OLRs (till day 254); and the second maintaining the OLR constant (from day 254 on). During these experiments the sum of time of the consecutive withdrawal and idle periods was fixed at 5 min. Additionally, in order to study the influence of TSS on the achieved conversions, from day 296 till the end of the experiments (day 320) the units were fed with a synthetic wastewater, which contained soluble COD as the only fraction of organic matter. Data attained in this time interval were compared with those achieved using industrial wastewater. 3.3.5. Analytical methods The pH, nitrate, ammonia, volatile suspended solids (VSS), total suspended solids (TSS), zone settling velocity (ZSV) and sludge volumentric index (SVI) were determined accordingly to Standard Methods (APHA, 1999) as described in Chapter 2. Concentrations of Chemical Oxygen Demand (COD) were determined by a modified method from the Standard Methods (Soto et al., 1989). Total COD (CODt) was measured directly in the sample and the soluble COD (CODs) from the filtered sample through 0.45 µm pore size filters, particulate COD (CODp) being calculated as the difference between CODt and CODs. The morphology of the granules was measured regularly by using an Image Analysis procedure proposed by Jeison and Chamy counting a sample of more than 200 granules (Jeison and Chamy, 1998). Biomass density, in terms of g VSS per litre of granules, was determined with dextran blue, which is not absorbed by the biomass (Jiménez et al., 1988) and following the methodology proposed by Beun (Beun et 3-11 Aerobic granulation with industrial wastewater in Sequencing Batch Reactors al., 1999) according to section 2.3 of Chapter 2. The presence of nitrifying bacteria in granules was followed by Fluorescence in situ hybridization (FISH) (Section 2.4 of Chapter2). This analysis was performed with a set of fluorescent labelled 16S rRNA-targeted DNA probes according to the procedure described by Amann (1995). Probes used for fluorescence in situ hybridisation and the formamide concentration used during hybridisation were EUB338 (probe sequence GCT GCC TCC CGT AGG AGT; formamide 35%) and NEU653 (Ammonium Oxidizing Bacteria, AOB) (probe sequence CCC CTC TGC TGC ACT CTA TTC CAT CCC CCT CTG CCG; formamide 40%). Fill Reaction Settle Draw Idle period Time (minutes) 3 171 1 3 2 A) Fill Anoxic Reaction Settle Draw Idle period Time (minutes) 3 30 141 1 3 2 B) Figure 3.3. Cycle distribution for the SBRs operation. A) R2 and B) R1. 3-12 Chapter 3 3.4. Results and discussion In the next section the main results obtained from the operation of both reactors, R1 and R2 are shown in terms of the physical characteristics of the granules, nitrogen and carbon compounds removal and concentration of suspended solids in the effluent. 3.4.1. Biomass granulation process The sludge used in both systems as inoculum was the typical flocculent activated sludge with a fluffy, irregular and loose morphology and relative abundance of filamentous microorganisms (Figure 3.4A; 3.5A). Settling properties of this sludge were: SVI of 200 mL/g VSS, and ZSV of 0.3 m/h. During the first seven experimental days an almost complete washout of the suspended biomass in both systems was observed. This was a result of the operation strategy of the systems, in which a very short settling and a fast effluent withdrawal period were applied to both reactors. Thus, either flocs or aggregates of biomass with settling velocity slower than 9 m/h were removed from the system as a result of mentioned conditions. Three weeks after the start up of the reactors the formation of small aggregates with an average diameter of 1.05 mm was observed in both systems. Suspended flocs gradually disappeared from the reactor and settling properties of the obtained aggregates were very good, SVI 60 mL/g VSS and ZSV of 20 m/h. Microscopic examination of the sludge showed that the morphology of the granular biomass was completely different from the flocculent sludge that was used as inoculum. The shape of the granules was round with a cauliflower like aspect and very clear outline (Figure 3.4; 3.5). The granular size distribution along the operational time was monitored and increased gradually with time of operation (Figure 3.6). These results indicated that the formation of aerobic granules was a gradual process from the flocculent seeded sludge to compact aggregates, further to granular sludge, of 2.3 mm after three weeks of operation, and finally to mature granules of 3.5 mm of averaged diameter (day 60). The evolution of size distributions of the granules is shown for day 23, day 60 and day 220 in terms of number and volume percentage. Most of the volume percentage of the biomass on day 23 corresponded to granules with a size distribution between 1.2 and 3 mm (Figure 3.5A). However on day 220, the 3-13 Aerobic granulation with industrial wastewater in Sequencing Batch Reactors volume percentage was shifted to diameters between 2.4 and 4.0 mm indicating the higher contribution of the big granules to the biomass concentration in the system. Operating day: 1 (A) Operating day :41 Operating day:57 Operating day: 170 Operating day :259 Operating day: 314 Figure 3.4. Pictures of the seeding sludge (100x) (A) and the aerobic granules on different operating days (Reactor R1). 3-14 Chapter 3 Operating day: 1 (A) Operating day :1 (A) Operating day:72 Operating day: 170 Operating day :219 Operating day: 314 Figure 3.5. Pictures of the seeding sludge (100x) (A) and the aerobic granules on different operating days (Reactor R2). 3-15 Aerobic granulation with industrial wastewater in Sequencing Batch Reactors A) Operating day 23 0 5 10 15 20 25 30 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 4.0 Diameter (mm) % Volume 0 5 10 15 20 25 30 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 4.0 Diameter (mm) Number B) Operating day 60 0 5 10 15 20 25 30 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 Diameter (mm) % Volume 0 5 10 15 20 25 30 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 Diameter (mm) Number C) Operating day 220 0 5 10 15 20 25 30 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 4.0 Diameter (mm) % Volume 0 5 10 15 20 25 30 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 4.0 Diameter (mm) Number Figure 3.6. Comparison of the size distribution between granular sludge on operating days 23 (A), 60 (B) and day 220 (C) in R1. 3-22 Chapter 3 0 20 40 60 80 100 0 30 60 90 120 150 180 210 240 270 300 330 Time (d) N removal efficiency (%) 1-2 g COD /L..d4-7 g COD /L..d Figure 3.13. N removal efficiency in R1 (•) and R2 (Ο). The measurement of the concentrations of these compounds was performed periodically along some operational cycles in order to explain the similar COD and nitrogen removal efficiencies obtained in both reactors at the end of each cycle. Typical concentration profiles during a cycle measurement are shown in the Figures 3.14 and 3.15 for the reactors R1 and R2, respectively. Figure 3.14 shows profiles measured on operating day 35 in R1 and on operating day 70 in R2. In both reactor, no nitrification or denitrification were carried out. However, Figure 3.15 shows profiles when both processes, nitrification and denitrification took place. These profiles were measured on operating day 260, when high OLR and NLR of 5 g COD/(L·d) and 0.4 g NH4+- N/(L·d), respectively, were applied. Except for the dissolved oxygen concentration (DO), the evolution of the concentrations of the measured compounds was similar in both reactors. The DO concentration in the R1 during the anoxic period was nearly 0.0 mg O2/L and in the reactor R2 was of 3 mg O2/L during first minutes of the cycle, and increased up to 6-7 mg O2/L during the rest of the cycle. In case of the R1 during the aerobic period, DO concentration was near the saturation value of 7 mg O2/L. Almost all the biodegradable COD and 3-23 Aerobic granulation with industrial wastewater in Sequencing Batch Reactors nitrate concentrations disappeared completely in both cases during the first 10 minutes of the cycle (Figure 3.15 (R1)). The COD concentrations measured at the end of the cycle were similar in both systems and could be attributed to the fraction of slowly biodegradable substrate contained in the wastewater. Nitrate was consumed via denitrification while biodegradable compounds might be partly aerobically oxidized, partly used as electron donor for denitrification and partly stored in the biomass. Ammonia was oxidised to nitrate during the aerobic period immediately after the disappearance of biodegradable COD from the liquid phase. Due to the intrinsic characteristics of these SBRs, apparent denitrifying and nitrifying specific activities may be calculated from the cycle measurements as follows: the denitrifying activity from the nitrate consumption until depletion of this compound and the nitrifying activity from the slope of ammonia consumption after restoration of aeration (Mosquera-Corral et al., 2005). The denitrification specific activity was of 0.28 g N/(g VSS⋅d) in R1, which is similar to 0.30 g N/(gVSS⋅d) obtained in the "aerobic" R2, but the nitrification specific activity was around 0.033 g N/(gVSS⋅d) in R2 and of 0.023 g N/(gVSS⋅d) in R1. In case of reactor R2, the fact that the granules exhibited denitrifying activities under aerobic conditions may be explained because during the initial minutes of the cycle, a high amount of soluble biodegradable COD was fed, which increased drastically its concentration in the reactor. This caused a higher transport by diffusion of this organic matter fraction inside the granules than that of oxygen during this period. Moreover, the 3 mg O2/L present during the feeding time of R2 were probably consumed by the outer layer of the granules and thus the inner layers, which were maintained under anoxic conditions, received enough carbon source and nitrate to support the denitrification process. In these experiments, the ammonium loading rate was between 0.1 and 0.7 g NH4+-N/(L⋅d) and ammonium fed was nitrified, even when the organic loading rate fed was as high as 5-7 g COD/(L⋅d). These loading rates were higher that those referred by Dangcong et al. (1999) in other granular SBR, in which a high quality effluent was obtained using synthetic urban wastewater as feeding medium at 0.15-0.18 g NH4+-N/(L⋅d) and 1.5-2.0 g COD/(L⋅d). 3-24 Chapter 3 0 50 100 150 200 010203040506070 Time (min) COD (mg/L) 0 50 100 150 200 0 10203040506070 Time(min) COD (mg/L) A) 0 10 20 30 40 0 10203040506070 Time (min) N (mg/L) 0 10 20 30 40 0 10203040506070 Time (min) N (mg/L) B) 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 0 10203040506070 Time (min) O2 (mg/L) 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 0 10203040506070 Time (min) O2 (mg/L) C) Figure 3.14. Typical concentration profiles during a cycle of the SBR in R1 on day 35 and R2 on day 70. A) (•) Total COD. B) (•) N-NH4+; (O) N-NO3-. C) Dissolved oxygen concentration. 3-25 Aerobic granulation with industrial wastewater in Sequencing Batch Reactors 0 100 200 300 400 500 0 50 100 150 200 Time (min) COD (mg/L) 0 0.1 0.2 0.3 0.4 0.5 0.6 SS (g/L) anoxic aerobic 0 100 200 300 400 500 0 50 100 150 200 Time (min) COD (mg/L) 0 0.1 0.2 0.3 0.4 0.5 0.6 SS (g/L) A) 0 10 20 30 40 50 60 0 50 100 150 200 Time (min) N (mg/L) aerobicanoxic 0 10 20 30 40 50 60 0 50 100 150 200 Time (min) N (mg/L) B) 0 1 2 3 4 5 6 7 8 9 0 50 100 150 200 Time (min) O2 (mg/L) anoxic aerobic 0 1 2 3 4 5 6 7 8 9 0 50 100 150 200 Time (min) O2 (mg/L) C) Figure 3.15. Typical concentration profiles during a cycle of the SBR in R1 and R2 on day 260. A) (•) Total COD; (Ο) TSS; () Soluble COD. B) (•) N-NH4+; (O) N-NO3-. C) Dissolved oxygen concentration. 3-26 Chapter 3 3.4.3. Solids concentration in the effluent An important parameter to take into account during the operation of the reactors in this study was the presence of suspended solids (TSS) in the industrial wastewater, which were not present in the composition of the influent of other granular SBRs (Tay et al., 2002a; Etterer and Widerer, 2001). The concentration of TSS in the industrial wastewater was high and ranged between 200 and 900 mg TSS/L, with a high fraction of volatile suspended solids (VSS) of around 75-97%. The amounts of suspended solids contained in the influent were partially removed in both SBRs, being the concentration of TSS in the effluent lower than in the influent, when the reactor was fed with industrial wastewater. The concentration of TSS in the effluent were comprehended between 50 mg TSS /L and 800 mg TSS/L for both reactors (Figure 3.16). 0.0 0.2 0.4 0.6 0.8 1.0 0 50 100 150 200 250 300 Time (d) g TSS/L 0 20 40 60 80 100 TSS rem (%) Figure 3.16. Concentration of TSS in the feeding (•) and TSS removal percentages in R1 ({) and R2 (). The presence of TSS in the generated effluent is a major drawback for developing industrial scale granular SBRs. The advantages of granular SBRs, high conversion capacity and good settling properties of granules, are neutralized by the presence of suspended solids in the effluent. This is a paradox as granular 3-27 Aerobic granulation with industrial wastewater in Sequencing Batch Reactors SBRs were usually presented in the literature as systems that may improve the behaviour of the bioreactor with regard to solids retention. The TSS in the effluent are constituted by the presence of very small flocs, which were always observed in the reactor. These small aggregates with relatively low ZSV are partly removed from the systems at the end of every operating cycle but a fraction of these aggregates remained in the systems. The TSS removal percentage was defined by comparing the concentration of these in the influent and in the effluent, without considering a feasible generation in the reactors. The TSS removal percentages were in both reactors around 80 % with a decrease to lower values between days 150 and 220, which could be a result of the increase of OLR (Figures 3.9 and 3.16). It was though that the capacity of the granular system to remove solids was related both with the daily amount of solids that were feed to the units and with the amount of biomass accumulated in the reactors. The relationship between the ratio of the CODp fed to the units and VSS in the reactors was plotted versus TSS in the effluent (Figure 3.17). Obtained results indicated that the TSS concentration in the effluent increased for CODp/SSV higher than 0.12 g/g. This indicated that it is necessary to limit the CODp/VSS ratio in the reactor below this value, in order to maintain a low TSS concentration in the effluent, as solids processing capacity of the granules is limited. A fraction of fed VSS can be degraded or accumulated in the system. Up to a concentration of 0.6 g VSS/L were removed between 90 and 220 days, however there was not relevant solids accumulation in the reactors after the first experimental weeks (Figure 3.7). Consequently, no significant accumulation of fed solids in the reactors took place, which indicated the degradation of the solids in the influent by the biomass. A basic strategy for diminishing TSS in the effluent was tested. This strategy was based on the increase of the water withdrawal rate from the systems by diminishing the lenght of the withdrawal period. For this reason, on day 219, the effluent withdrawal time was manipulated from 3 to 1 min and on day 245 was diminished to 0.5 minutes. Afterwards it was sequentially increased from 0.5 to 1 min and from 1 min to 3 min (Table 3.2). With this strategy the partial retention of suspended solids previously observed decreased (Figure 3.18). Most of the 3-28 Chapter 3 solids in suspension and small flocs were washed out during the first cycles after every reduction of the withdrawal time, and thus a new stable value for TSS in the effluent was achieved. In both systems average concentration of solids in the effluent was around 450 mg TSS/L, when the withdrawal time was 3 min, but it decreased strongly to 200 and 150 mg TSS/L when the withdrawal time was diminished to 1 and 0.5 min, respectively. This proved that the strategy had a positive effect in the effluent quality regarding to solids concentration. 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.00 0.05 0.10 0.15 0.20 0.25 0.30 CODp/VSS TSSef (g/L) Figure 3.17. Evolution of the CODp/ fed-VSS on the TSS concentration in the effluent of R1 (♦) and R2 ({). Data obtained from the experiments carried out with industrial wastewater as feeding medium and length of the withdrawal period 3 min. From day 296 both reactors were fed with the same free of solids synthetic wastewater which was used during the start up of R1. The concentration of suspended solids in the effluent was around 200 mg TSS/L, which were lower than the 450 mg TSS/L that were measured using the industrial wastewater with the same withdrawal time of 3 min. This indicated that the solids present in the effluent not only depended on the biomass washed out from the reactor, but also on the solids content of the feeding. On the other hand, Figure 3.18 showed that the content of TSS in the effluent during this experiment was similar or even 3-29 Aerobic granulation with industrial wastewater in Sequencing Batch Reactors higher than the value obtained when the industrial wastewater was fed to the system with a withdrawal time of 1 min or 0.5 min. The presence of biomass in the effluent, even when no solids are present in the feeding media, might be originated by the breaking up of the granules in fragments caused by diffusion limitation of substrates and subsequent cellular decays by lysis. This fact occurred when the size of granules was too big and a decay processes might then take place in the inner zone of the granules as it occurs in the case of biofilms (van Benthum et al., 1996). From an experiment with a nitrifying lab-scale biofilm airlift suspension (BAS) reactor (van Benthum et al., 1996) lasting more than 500 days, the continuous break-up of granules was observed. In the effluent of the BAS reactors small fragments, size 0.2 to 0.3 mm, were always observed, broken off from larger granules or biofilms and washed out. 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 3 min IW 1 min IW 1/2 min IW 3 min SW Withdrawal time TSS (g/L) Figure 3.18. Evolution of the effluent TSS on the water withdrawal time (OLR between 5 and 7 g COD/L.d). IW = industrial wastewater and SW = synthetic wastewater without TSS. Experiments shown that there are at least 3 causes that originated the presence of small aggregates in the SBR reactors: the own presence of TSS in the influent, the generation of small biomass aggregates during the cycle due to biomass growth and the small biomass patches that are detached from the granules. The first and last causes were pointed out during our studies. The 3-30 Chapter 3 second cause, growth of small biomass aggregates was demonstrated during experiments in which withdrawal time was manipulated, as the modification of this parameters do not appear to influence either detachment or the retention of the feeding solids by the granules. 3.5. Conclusions • The formation of granules in two SBRs was achieved by using a industrial wastewater coming from a dairy analysis laboratory as influent. Granules with good settling properties were obtained, SVI of 60 mL/g VSS, and ZSV of 20 m/h. This made feasible to operate the system with high exchange volume and thus organic and nitrogen loading rates applied to both systems were high, up to 7 g COD/(L·d) and 0.7 g NH4+- N/(L·d). • Nitrogen removal efficiency was similar in both units, even considering that R2 was operated always under aerobic conditions. Nitrogen and COD removal efficiencies were 80 and 70 %, respectively. Nitrate disappeared in both units during the first minutes of the feeding period, although in R2 dissolved oxygen concentration was higher than 3 mg O2/L. Thus, denitrification might take place in R2 in the inner core of the granules, oxygen being depleted by the outer layers. • The TSS concentration in the effluent was between 50 and 700 mg TSS/L during the different operational stages. It was found that the presence of TSS in the effluent was a result of at least of three causes: the own presence of TSS in the influent; the detachment of small biomass patches from the granules and the growth of small flocs that were washed out. • The presence of TSS in the effluent of the SBRs was strongly affected by either the length of the withdrawal period or by the applied particulated COD to biomass ratio (CODp/VSS) to the systems. o The TSS in the effluent, lower than 200 mg TSS/L, were attained when the systems operated with an CODp/VSS ratio lower than 0.12 g COD/g VSS. 3-31 Aerobic granulation with industrial wastewater in Sequencing Batch Reactors o With regard to the effect of the length of the withdrawal period, there was a strong reduction of the averaged TSS content in the effluent from 450 to 200 and 150 mg TSS/L when this time was diminished sequentially from 3 to 1 and 0.5 min, respectively. This was caused by a more intensive washout of small suspended biomass aggregates that took place when the lenght of this period was shortened, which reduced proliferation of small flocs in the systems. Anyway, results pointed out that the presence of solids in the effluent of granular SBRs is intrinsic with the behaviour of these units. To resume, diminution of withdrawal time and the limitation of CODp/VSS applied to the systems have a positive effect on the TSS in the effluent. 3.6. References Amann R.I. (1995). In situ identification of micro-organisms by whole-cell hybreidization with r RNA-targeted nucleic acid probes, p.1-15. In A.D.L: Akkerman, J.D. van Elsas, and F.J. de Brujin (ed.), Molecular microbial ecology manual. Kluwer Academic Publisher, Dordrecht, The Netherlands. APHA-AWWA-WPCF. (1999). Standard Methods for the examination of water and wastewater. 20th Edition. Clesceri, L.S., Greenberg, A.E. & Eaton, A.D. (eds.). Arrojo B., Omil F., Garrido J.M. and Méndez R. (2003). Combinación de un filtro anaerobio y un sistema SBR para el tratamiento de las aguas generadas en un laboratorio de análisis de productos lácteos. Afinidad, 60, 344-354. Blackall L.L., Harbers A. E., Greenfield P.F. and Hayward A.C. (1991). Foaming in activated sludge plants: a survey in Queensland, Australia and an evaluation of some control strategies. Water Research, 25 (3), 313-317. Beun J.J., Hendriks A., Van Loosdrecht M.C.M., Morgenroth E., Wilderer P:A: and Heijnen J.J. (1999). Aerobic granulation in a sequencing batch reactor. Water Research, 33 (10), 2283-2290. Dangcong P., Bernet N., Delgenes J-P and Moletta R. (1999). Aerobic granular sludge- A case report. Water Research 33, (3), 890-893. 6-34 Chapter 6 In reactor SBRM for the values of the specific input power of 0.003-0.09 kW/m3 (corresponding to 60-180 rpm) the value of activity was practically constant around 0.40 g N/(g VSS·d). However, this value decreased to 0.25 g N/(g VSS·d) when the specific input power applied to the reactor was 0.23 kW/m3 (250 rpm). In a similar way Chisti (2000) found constant growth rates for cells grown in serum-free batch cultures using a Rushton turbine with stirring speed up to 270 rpm. In the case of SBRF1 and 2 the values of the SAA were practically constant around 0.35 g N/(g VSS·d) for the specific input power comprehended between 0.027 kW/m3 and 0.041 kW/m3. However, this value decreased to 0.15 g N/(g VSS·d) when the specific power applied to the reactor was 0.057 kW/m3. The activity decreased to 0.05 g N/(g VSS·d) when the specific input power was increased to 0.075-0.095 kW/m3. At this value, a rupture of the granules occurred and the biomass retention worsened due to the breakage of the granules and a floatation caused by nitrite accumulation. These results clearly show that the breakage of the granules and the reduction of the activity were a process that occurred when the shear stress was increased independently of how this stress was applied to the system. Figures 6.23a and b show the values of the granule diameter and the specific activity measured depending on the specific input power. The lineal distribution achieved was similar to that found by Henzler (2000). This author also found a strong influence of the specific input power and the impeller type on the disintegration of flocs, so that the effect of the operating conditions and the reactor type. The SBR has been proved to be a suitable system for the enrichment of a microbial community with an extremely slow growth rate like that performing Anammox process (Strous et al., 1998). Dapena-Mora et al. (2004c) already reported the growth of Anammox bacteria in form of granules in SBR systems which permit a homogeneous distribution of substrates, products and biomass, an efficient retention of the biomass and the prevention of the formation of local accumulations of nitrite that could inhibit the Anammox process. However, the influence of the shear forces caused by the mechanical stirring and gas upflow velocities in SBR systems where the Anammox process is performed was never studied. 6-35 Effects of hydrodynamic conditions on Anammox granules in a SBR The increase of the stirrer speed or gas upflow velocity, which involves an increase of the shear stress, was found to provoke changes on the properties of biomass aggregates and on the process efficiency. The possible reasons for these effects are now discussed. In terms of reactor operation the increase of the shear stress up to 250 rpm in SBRM and up to 7.4 cm/min in SBRF provoked a worsening of biomass retention inside the reactor and a decrease of Anammox efficiency. Both combined phenomena have already been observed in previous studies with SBRs when the specific NLRs applied to the reactors exceeded the corresponding Specific Anammox Activity (SAA) of the biomass, which remained practically constant (Dapena-Mora et al., 2004a). Different effect was observed in the present study where the biomass SAA decreased from 0.40 to 0.25 g N/(g VSS·d) when the shear stress increased due to the increase of stirrer speed till 250 rpm and it decreased from 0.35 to 0.10 g N/(g VSS·d) when the gas upflow velocity increased to 7.4 cm/min. At this point the specific NLRs applied were constant and exceeded the SAA causing the instability of the process. Similar decrease of biomass activity in relation to the shear forces was observed by several authors (Jüsten et al.,1998; Biedermann, 1994; Bücher, 1993; Casas-López et al., 2005) in systems applied to grow cells. However, the mechanism responsible for this effect has not been yet clearly established. Chisti (2000) also observed the loss of the cell growth rate when high speeds and gas upflow velocities were used (more than 270 rpm and 9.7 cm/min, respectively) without cellular lysis being involved in the process and keeping more than 97% of the cells viable. This author proposes that sublethal levels of hydrodynamic forces clearly affected cell growth and reproductive processes without cellular breakage or other physical damage. In the present study the reduction of the observed decrease of the SAA of the biomass might be somehow related to cellular lysis. Total Organic Carbon (TOC) concentrations in the liquid media increased from 8.0 to 13.5 mg TOC/L in case of 180 and 250 rpm, respectively. This increase of TOC accounts for the amount of biomass reduction in the reactor from day 170 to day 180 (100 mg VSS/L). Although this reduction of biomass concentration in the system was not enough to justify the decrease of 6-36 Chapter 6 SAA of the biomass, but it was probably associated to the breakage of the granules. The rupture of the Anammox granules led to smaller size aggregates which should benefit the substrate diffusion (van Benthum et al., 1997) and improve the activity of the biomass placed in the inner cores of the granules with a consequent increment of SAA. Strous et al. (1998), working with Anammox granules in a SBR, postulated that 50% of the Anammox biomass was inactive because of substrate limitations inside the granules. Thus, this size reduction should exert a positive effect on the SAA, which was not observed in the reactor. The rupture of the granules or even the detachment of weak patches of biomass from the surface of the granules involved an increase of suspended solids wash-out of the reactor due to biomass flotation closely related to the nitrite accumulation in the media (Dapena-Mora et al., 2004a). However, this trend was not followed by the SVI value, which decreased indicating that the settling properties of the sludge were improved. This effect was related to the fact that the granules were smaller and more compact than in the previous stages. As a consequence the density of the granules experienced an increased due to the rupture of part of the granules. Another possible reason for the loss of activity could be related to the loss of catabolic and anabolic intermediates to the external environment which can have an important effect on the biomass yield in the case of slow-growing bacteria like Anammox. These bacteria must make up these losses by investing endogenous electron donors (Sinninghe-Damste et al., 2002). Hydroxylamine and hydrazine (intermediate compounds of the Anammox process) have been detected experimentally outside the Anammox cells in previous studies. Although in the present study no measurements of these compounds were performed the addition of slight concentrations of hydroxylamine did not favour the Anammox activity. Besides this phenomenon if relevant could be related to the Anammox cycle, where cytochrome C has an important role. It is currently hypothesized that these c-type cytochromes in “K. stuttgartiensis” is the main responsible for electron transfer from hydrazine to nitrite (Cirpus et al., 2005). It could be that the loss of activity was related to the loss of the cytochrome C–hemes, the reduction of 6-37 Effects of hydrodynamic conditions on Anammox granules in a SBR nitrite could not take place and so the typical reddish colour can not be maintained in the Anammox biomass. A) 0.00 0.20 0.40 0.60 0.80 1.00 0.00 0.01 0.10 1.00 P/V(kW/m3) Activity (g N/(g VSS·d)) 0.00 0.20 0.40 0.60 0.80 Feret diameter (mm) B) 0.00 0.20 0.40 0.60 0.80 1.00 0.01 0.1 1 P/V (kW/m3) Activity (g N/(g VSS·d)) 0.00 0.20 0.40 0.60 0.80 1.00 Feret diameter (mm) Figure 6.23. Comparison between results of SBRM (A) and SBRF1 and 2 (B). Evolution of the Specific Anammox Activity (S) and the average feret diameters () with the different specific powers tested. 6-38 Chapter 6 6.5. Conclusions • The presented results show the high capacity of the Anammox process in order to support the high stress supplied by mechanical stirring or gas upflow velocity in SBR systems. The Anammox process was successfully carried out at specific input power between 0.003 and 0.09 kW/m3 (up to 180 rpm) for the mechanically stirred reactor and between 0.003 and 0.057 kW·m-3 (up to 5.29 cm/min) for the gas upflow recirculating reactor. However, a reduction on the stability of the process took place when the stirring speed was increased to 250 rpm and the gas upflow velocity to 7.4 cm/min, which means a specific input power applied to the system of 0.23 kW/m3 and 0.075 kW/m3, respectively. • This reduction on the stability affected mainly the specific Anammox activity of the sludge and the biomass retention in the system. • Activity of the Anammox granules was decreased around 50% and 85% for SBRM and SBRF, respectively, which caused a loss of the system efficiency due to a combination of cellular lysis and granules breakage. • The biomass retention worsened due to the breakage of the granules and floatation caused by nitrite accumulation. However, the granules were more compact and the density was increased. When operated at full-scale the control of the shear stress in SBR systems is required in order to perform the process in stable conditions. Shear forces affect to the activity of the Anammox system only in case of application of high stress. When the aim is the formation of granular biomass further research must be focused on the determination of the minimum needed shear stress. It is important to highlight that the activity, the size of the granules and the stability of the process was recovered when the initial shear stress were restored. 6-39 Effects of hydrodynamic conditions on Anammox granules in a SBR 6.6. References Alphenaar P.A., Visser A. and Lettinga G. (1993). The effect of liquid upflow velocity and hydraulic retention time on granulation in UASB reactors treating wastewater with a high-sulphate content. Bioresource Technology, 43, 249-58. Amann R.I. (1995). In situ identification of micro-organisms by whole-cell hybridization with RNA-targeted nucleic acid probles, p.1-15. In A.D.L.: Akkerman, J.D., van Elsas and F.J. de Brujin (ed), molecular microbial ecology manual. Kluwer Academic Publisher, Dordrecht, The Netherlands. APHA-AWWA-WPCF. (1999). Standard Methods for the examination of water and wastewater. 20th Edition. Clesceri, L.S., Greenberg, A.E. & Eaton, A.D. (eds.). Arrojo B., Mosquera-Corral A., Garrido J.M. and Méndez R. (2004). Aerobic granulation with industrial wastewater in sequencing batch reactors. Water Research, 38, 3389-3399. Arrojo B., Mosquera-Corral A., Campos J.L. and Méndez R. (2006). Effects of mechanical stress on Anammox granules in a sequencing batch reactor (SBR). Journal of Biotechnology, 123, 453-463. Arcand Y., Guitot SR., Desrochers M. and Chavarie C. (1994). Impact of the reactor hydrodynamics and organic loading on the size and activity of anaerobic granules. Chemical Engineering Journal, 56, 23-35. Bang W., Nikov I., Delmas H. and Bascoul A. (1998). Gas-Liquid mass transfer in a new three-phase stirred airlift reactor. Journal Chemical Technology Biotechnology, 72, 137-142. Beun J.J., Hendriks A., Van Loosdrecht M.C.M., Morgenroth E., Wilderer P.A. and Heijnen J.J. (1999). Aerobic granulation in a sequencing batch reactor. Water Research, 33 (10), 2283-2290. Biedermann A. (1994). Scherbeanspruchung in Bioreaktoren. Dissertation Universität Köln. Bücher K. (1993). Scherbeanspruchung in Bioreaktoren. Master Thesis Universität Pader-born. 6-40 Chapter 6 Buys B.R., Mosquera-Corral A., Sánchez M. and Méndez R. (2000). Development and application of a denitrification test based on gas production. Water Science and Technology, 41, 113-120. Casas-López J.L., Sánchez-Pérez J.A., Fernández-Sevilla R., Rodríguez-Porcel E.M. and Chisti Y. (2005). Pellet morphology, culture rheology and lovastatin production in cultures of Aspergillus terreus. Journal of Biotechnology, 116, 61-77. Chang H.T., Rittmann B.E., Amar D.R., Ehrlinger O. and lesty Y. (1991). Biofilm detachment mechanisms in a liquid fluidized bed. Biotechnology and Bioengineering, 38, 499-506. Chen M.J., Zhang Z. and Bott T.R. (1998). Direct measurement of the adhesive strength of biofilms in pipes by micromanipulation. Biotechnology Techniques, 12, 875-880. Chisti Y. (2000). Animal-cell damage in sparged bioreactors. Trends in Bitechnology, 18, 421-431. Cirpus,I.E.Y., de Been,M., Op den Camp,H.J.M., Strous,M., Le Paslier,D., Kuenen,G.J., and Jetten,M.S.M. (2005) A new soluble 10 kDa monoheme cytochrome c-552 from the anammox bacterium Candidatus "Kuenenia stuttgartiensis". Fems Microbiology Letters, 252 (2), 273-278. Dapena-Mora A., Campos J.L., Mosquera-Corral A., Jetten M.S.M. and Méndez R. (2004a). Stability of the Anammox process in a gas-lift reactor and a SBR. Journal of Biotechnology, 110, 159-170. Dapena- Mora A., Arrojo B., Campos J.L., Mosquera-Corral A. and Méndez R. (2004b). Improvement of the settling properties of Anammox sludge in an SBR. Journal of Chemical Technology and Biotechnology, 79 (12), 1412- 1420. Dapena-Mora A., Van Hulle S. W.H., Campos J.L., Méndez R. Vanrolleghem P.A. and Jetten M. (2004c). Enrichment of Anammox biomass from municipal activated sludge: experimental and modelling results. Journal of Chemical Technology and Biotechnology, 79, 1421-1428. 6-41 Effects of hydrodynamic conditions on Anammox granules in a SBR Dapena-Mora A., Campos J.L., Mosquera-Corral A. and Méndez R. (2006). Anammox process for nitrogen removal from anaerobically digested fish canning effluents. Water Science and Technology, 53 (12), 265-274. Daims H., Brühl A., Amann R., Schleifer K.-H. and Wagner M. (1999). The domain-specific probe EUB338 is insufficient for the detection of all Bacteria: Development and evaluation of a more comprehensive probe set. Systematic and Applied Microbiology, 22, 434-444. Gjaltema A., van Loosdrecht M.C.M. and Heijnen J.J.(1997). Abrasion of suspension biofilm pellets in airlift reactors: effect of particle size. Biotechnology and Bioengineering, 55, 206-215. Guven D., Dapena A., Kartal B., Schmid M.C., Maas B., Pas-Schoonen K., Sozen S., Mendez R., Op den Camp H.J.M., Jetten M.S.M., Strous M. and Schmidt I. (2005). Propionate oxidation by and methanol inhibition of anaerobic ammonium-oxidizing bacteria. Applied and Environmental Microbiology, 71(2), 1066-1071. Henzler H.J. (2000). Particle stress in bioreactors. Advances in Biochemical Engineering and Biotechnoloy, 67, 36-82. Jiménez B., Noyola A., Capdeville V., Roustan M. and Faup G. (1988) Dextran Blue coulorant as a reliable tracer in submerged filters. Water Research, 22, 1253-1257. Jüsten P., Paul G.C., Nienow A.W. and Thomas C.R. (1998). Dependence of Penicillium chrysogenum growth, morphology, vacuolation and productivity in fed-batch fermentations on impeller type and agitation intensity. Biotechnology and Bioengineering, 59, 762-775. Klapwijk A., Jol C. and Donker H.J.G.W. (1979). The application of an upflow reactor in the denitrification step of biological sewage purification. Water Research, 13, 1009-1015. Klapwijk A., van der Hoeven J.C.M. and Lettinga G. (1981). Biological denitrification in an upflow sludge blanket reactor. Water Research, 15, 1-6. 6-42 Chapter 6 Kwok W.K., Picioreanu C., Ong S.L., van Loosdrecht M.C. M., Ng W.j. and Heijnen J.J. (1998). Influence of biomass production and detachment forces on biofilm structures in a biofilm airlif suspension reactor. Biotechnology and Bioengineering, 58, 400-407. Liu Y. and Tay J.H. (2002). The essential role of hydrodynamic shear force in the formation of biofilm and granular sludge. Water Research, 36, 1653-1665. Liu Y, Xu H.L., Yang S.F. and Tay J. H. (2003). Mechanisms and models for anaerobic granulation in upflow anaerobic sludge blanket reactor. Water Research, 37, 661-673. Liu Y. and Tay J.H. (2004). State of the art of biogranulation technology from wastewater treatment. Biotechnology Advances, 22, 533-563. Mohan S.B., Schmid M., Jetten M. and Cole J. (2004). Detection and widespread distribution of the nrfA gene encoding nitrite reduction to ammonia, a short circuit in the biological nitrogen cycle that competes with denitrification. Fems Microbiology Ecology, 49 (3), 433-443. Mosquera-Corral A., Vázquez-Padín J.R., Arrojo B., Campos J.L. and Méndez R. (2005). Nitrifying granular sludge in a sequencing batch reactor. In: Aerobic Granular Sludge. Water and Environmental Management Series. IWA Publishing. Munich, (63-70). Neef A., Amann R., Schlesner H. and Schleifer K.-H. (1998). Monitoring a widespread bacterial group: in situ detection of planctomycetes with 16S rRNA-targeted probes. Microbiology, 144, 3257-3266. Noyola A. and Moreno G. (1994). Granule production form raw waste activated sludge. Water Science and Technology, 30, 339-346. Ohashi A. and Harada H. (1994). Adhesion strength of biofilm developed in an attached-growth reactor. Water Science and Technology, 29,10 O’Flaherty V., Lens P.N., de Beer D. and Colleran. E. (1997) Effect of feed composition and upflow velocity on aggregate characteristics in anaerobic upflow reactors. Appied Microbiology and Biotechnology, 47, 102-107. 6-43 Effects of hydrodynamic conditions on Anammox granules in a SBR Pinho F.T., Piqueiro F.M., Proenca M.F. and Santos A.M. (1997). Power and mean flow characteristics in mixing vessels agitated by hyperboloid stirrer. Canadian Journal of Chemical Engineering, 75 (5), 832-842. Sánchez-Mirón A., Cerón M.C., Contreras A., García F., Molina E. and Chisti Y. (2003). Shear stress tolerance and biochemical characterization of Phaedactylum tricornutum in quasi steady-state continuous culture in outdoor photobioreactors. Biochemical Engineering Journal, 16, 287-297. Schmid M., Schmitz-Esser S., Jetten M. and Wagner M. (2001). 16S-23rDNA intergenic spacer and 23S rDNA of anaerobic ammonium-oxidizing bacteria: implications for phylogeny and in situ detection. Environmental Microbiology, 3 (7), 450-459. Schmidt I., Hermelink C., van de Pas-Schoonen K., Strous M., Camp H.J., Kuenen J.G.and Jetten M.S.M. (2002). Anaerobic ammonia oxidation in the presence of nitrogen oxides (NOx) by two different lithotrophs. Applied Environmental Microbiology, 68 (11), 5351-5357. Schmid, M., K. Walsh, R. Webb, W. I. C. Rijpstra, K. van de Pas Schoonen, M. J. Verbruggen, T. Hill, B. Moffett, J. A. Fuerst, S. Schouten, J. S. S. Damsté, J. Harris , P. Shaw, M. Jetten, and M. Strous (2003). Candidatus "Scalindua brodae", spec. nov., Candidatus "Scalindua wagneri", spec. nov., two new species of anaerobic ammonium oxidizing bacteria. Systematic and Applied Microbiology, 26, 529–538. Schmid M, Mass B., Dapena A., et al. (2005). Biomarkers for In situ Detection of Anaerobic Ammonium-Oxidizing (Anammox) bacteria. Minireview. Applied and Environmental Microbiology, 71 (4), 1677-1684. Sinninghe-Damste J.S., Strous M., Rijpstra W.I.C., Hopmans E.C., Geenevasen J.A.J., van Duin A.C.T., van Niftrik L.A. and Jetten M.S.M. (2002). Linearly concatenated cyclobutane lipids form a dense bacterial membrane. Nature 419, 708-712. Sliekers A., Third K.A., Abma W., Kuenen J.G. and Jetten M.S.M. (2003). CANON and Anammox in a gas-lift reactor. FEMS Microbiology Letters, 218, 339-344. 7-4 Chapter 7 The combination of a membrane system with a SBR provides procedural advantages for both processes. The use of membranes can reduce the operation period since the membrane separation of the solids from the effluent requires no settling phase and clear-water can be extracted even during the mixing phase (Kang et al., 2003). In addition, the separation of biological sludge by means of a membrane leads to complete retention of biomass resulting in a high mixed liquor suspended solids concentration inside the reactor. This allows a very high treatment capacity for a membrane-coupled sequencing batch reactor (MSBR) (Krampe and Krauth, 2000). In a MSBR system, it would be very important, and also difficult to select the most appropriate SBR phase in which the membrane filtration could be performed at its best. The reason for this relies on the many types of SBR systems currently in use which operate in different operation modes such as: continuous influent/time based, non-continuous influent/time based, volume based, and intermittent cycle system, and various other system modifications (Banas et al., 1999; Schleypen et al., 1997; Ketchum, 1997; Irvine et al., 1997). Although combination of membrane filtration and SBR should be reengineered to get a MSBR of good performance, the efficiency of the membrane process in MSBR would certainly be dependent on the physicochemical and biological conditions of each SBR phase as well as the type and cycle format of the SBR. Regarding the operation of the membrane certain aspects must be taken into account to achieve optimal operation conditions and are basically related to the fouling problems associated to the solids content in the liquid media. The presence of fouling provokes problems of operation and reduces the achievable flow rate of liquid through the membrane system, decreasing at the same time the quality of the produced effluent (Wei et al., 2006; Cho and Fane, 2002; Ognier et al., 2004; Tyszler et al., 2006; Judd, 2004). For this reason the operation of the membrane must be followed by knowing the values of certain operational parameters such as the critical flux. The concept of the critical flux has been introduced recently by a number of authors providing theoretical and experimental evidence. Fields et al. (1995) and Howell (1995) stated that “there exists one flux below which a decline of flux with time does not occur; above this flux, fouling is observed. This flux is termed as the critical flux and its value 7-5 A membrane coupled to a SBR for water reuse and removal of coliform bacteria depends on the hydrodynamics and probably also on other variables”. This flux should be equivalent to the corresponding clean water flux at the same transmembrane pressure (TMP). Theoretical calculations made by Bacchin et al. (1995) suggested that the critical flux depends strongly on the particle size. For small particles of the order of 0.1 µm back-diffusion away from the membrane surface is important and the critical flux depends mainly on the surface charge of particles. For particles over 1 µm, the shear-induced diffusion which lifts particles away from the membrane surface and this is critical for the membrane fouling. Fouling can be reduced by maintaining turbulent conditions, operating at subcritical flux and selection of a suitable fouling-resistant membrane material (Gander et al., 2000). The membrane bioreactors (MBR) present a means to biologically treat high COD or BOD loaded wastewaters and also to reduce the microbial content of the wastewater. Because membranes are an absolute barrier for bacteria and in the case of ultra filtration (UF) also for viruses, the MBR process provides a considerable level of physical disinfection (Melin et al., 2006). The microfiltration membranes applied in MBRs have proven to achieve consistently high removal rates for microbiological parameters such as total coliforms, faecal coliforms and even bacteriophages. The log removal reported varied between 6-8 log for bacteria and 3-5 log scales for viruses (Stephenson et al., 2000). MBR effluents were found to be compliant with the EU Bathing Water Directive (EC/160/75) including parameters such as total coliforms, faecal coliforms, Streptococcus faecalis and Coliphages (Günder and Krauth, 1999). Experiments conducted by Cicek et al. (1998) with indicator viruses MS-2, which have an approximate diameter of 25 nm and were spiked to the feed of the membrane, revealed removal percentages of 94.5%. A 5.88 log removal for bacteriophages was observed by Ueda and Horan (2000) in an MBR treating settled sewage and partially attributed to retention by the membrane and adsorption to activated sludge. A 6.86 log removal was found for faecal coliforms. This compares favourably with a conventional activated sludge treatment plant, showing only 1.31 log reduction for bacteriophages and 2.34 log for faecal coliforms (Ueda and Horan et al., 2000). 7-6 Chapter 7 The favourable microbiological quality of the effluent of MBRs is a major factor in their frequent selection for water reuse, even if full disinfection can not be expected, particularly considering the distribution and storage components of a full-scale system, which can be prone to re-growth of microorganisms and contamination from various sources (Coté et al., 1998). The biggest MBR system of the world up to date, the municipal wastewater treatment in Kaarst, Germany, features online particles turbidity measurement in the main effluent discharge line. Periodically integrity testing can be performed with full-scale modules with bubble point or pressure-decay tests (Melin et al., 2006). Regarding the applicability of the MBR systems for water reuse it has to be taken into account that once governments are convinced of the need of water reuse, it is not always easy to obtain a permit for the reuse of reclaimed water, and this despite the European Unions’ wide encouragement to reuse wastewater treatment effluents. For several member states one of the major problems is the lack of clear criteria on when to reuse and on quality standards (Bixio et al., 2006). Despite the fact that no guidelines or regulations yet exist at the European Union level, several member states or autonomy regions have now published their own standards or regulations. For example, in Italy with Decree of Environmental Ministry 185/2003 the quality requirements were defined for the three water reuse categories: agriculture, non-potable urban and industrial. At the same time a reduction of microbial load is necessary for water reuse in agriculture, as stated in the Italian legislation, which indicates a limit of 10 CFU/100mL for E. Coli (Decree, 185/2003). In Spain, in 1985 the Government indicated water reuse as a possibility, but no specific regulations followed. A draft legislation has been issued in 1999, with a set of standard for 14 possible applications of treated water. The proposed microbiological standards range is strongly similar to those of the California Title 22 regulations. 7-7 A membrane coupled to a SBR for water reuse and removal of coliform bacteria 7.2. Objectives The main objective of this study was the evaluation of the applicability of the coupled system comprising a bioreactor and a membrane system for the removal of organic matter and faecal coliforms and Escherichia Coli in order to obtain water suitable for reuse. Two different configurations were tested using two different bioreactors: (i) a membrane coupled to a SBR (MSBR) and (ii) a membrane continuous bioreactor (MBR) was studied with particular attention paid to the fouling and the hydraulic conditions. 7.3. Materials and methods 7.3.1. Experimental set-up A. Membrane-coupled SBR The laboratory-scale SBR reactor was a cylindrical vessel with a working volume of 20 L. Peristaltic pumps were used for feed, discharge of the effluent and biomass purging. During the oxic phase, oxygen was supplied by an air blower (mass transfer coefficient, KLa = 0.2 min-1). Mechanical mixing was supplied during both the oxic and anoxic phase at a rotating speed of 400 rpm. The actions of the pumps, aeration system and stirrer were controlled by four timers (Figure 7.1). The reactor was equipped with a data acquisition system MARTINA (Ficara et al., 2000) (Multiple Analyse Reprogrammable TItratioN Analyser), Spes scrl, Fabriano (AN)) with the following probes: - ORP probe (InLab 501, Mettler Toledo- Greifensee, Swithzerland). - Dissolved oxygen probe (COS3S, Endress-Hauser, Reinach,, Switzerland). - pH electrode (InLab 412, Mettler Toledo Greifensee, Switzerland). - Temperature probe (Pt100, TRM). Data were acquired each 20 seconds by means of a data acquisition system. 7-8 Chapter 7 400 PLC Influent Effluent O2 Thermostate 400 PLC Influent Effluent O2 Thermostate Figure 7.1. Sequencing Batch Reactor and membrane. 7-9 A membrane coupled to a SBR for water reuse and removal of coliform bacteria Temperature was maintained at 25 ºC by a thermostatic bath, while pH varied between 7.2 and 8.3. The effluent from the SBR was pumped for filtration with a hollow fibre membrane module ZW-1 (Zenon) with a pore size of 0.2 µm and an effective surface area of 0.093 m2. The external diameter of each fibre was 1.8 mm while the internal diameter was 0.5-1.0 mm. The membrane was 50 mm wide and 175 mm long (Figure 7.2). The ZW-1 module comes with an extended aeration tube that is also used to attach the module to the support bracket to hold it in place vertically. It has two holes on the top header: one for the permeate and one for pressure measurement. The permeate is drawn only from the top header. The central aeration tube supplies air to the bottom header where air diffusers are located. The ZW-1 module was connected to a vacuometer in order to measure the Trans-Membrane Pressure (TMP). Figure 7.2. Membrane module (Zenon ZW-1). 7-10 Chapter 7 B. Hydraulic conditions Two configurations of the collocation of the membrane were compared: (i) a membrane ZW-1 coupled to a SBR with intermittent permeate extraction (MSBR) (Figure 7.3) and (ii) a membrane bioreactor with continuous permeate extraction (MBR) (Figure 7.4). Two laboratory-scale SBRs with a total volume of 5 L and a working volume of 4 L were used. In the first configuration, the system was operated with the same reaction phase as the 20 L SBR described above, but no sedimentation was performed since the membrane module was used for effluent extraction. The second reactor was operated as a MBR constantly aerated and with constant permeate extraction. Influent Intermittent permeate extraction O2 Influent Intermittent permeate extraction O2 Figure 7.3. Membrane coupled to a SBR with intermittent permeate extraction (MSBR). 7-11 A membrane coupled to a SBR for water reuse and removal of coliform bacteria Influent Continuous permeate extraction O2 Influent Continuous permeate extraction O2 Figure 7.4. Membrane Bioreactor (MBR). 7.3.2. Feeding media Initially, the reactor was fed with a synthetic medium made of peptone, meat extract and salts (COD = 600 mg/L, Ntot = 75 mg/L, Ptot = 11.4 mg/L) (Table 7.1) and the trace solution according to Larsen and Harremoes (1994) (Table 7.2). The microbial inoculum came from a primary treated urban wastewater (Table 7.3) which was added to the synthetic feed (1/10 v/v). Finally, some cycles were performed feeding urban wastewater to assess the membrane efficiency on undiluted real wastewater. Table 7.1. Composition of synthetic medium used to feed the SBR. Compounds Values (g/L, except the traces solution) Peptone 0.457 Meat extract 0.236 NaCl 0.015 CaCl2·2H2O 0.012 MgSO4·7H2O 0.0045 K2HPO4 0.06 Traces solution 0.10 mL/L 7-12 Chapter 7 Table 7.2. Composition of traces solution. Compounds Values (g/L) CuCl2*2H2O 0.228 CoCl2*6H2O 0.317 0.527 0.527 (NH4)6Mo7O24*4H2O MnCl2*4H2O Na2B4O7*10H2O ZnCl2 0.127 0.363 FeSO4*7H2O 3.7 Table 7.3. Average composition of the urban wastewater treatment plant of Pero (Milano). Compounds Values (mg/L, except pH) pH 7.73 TSS 86.79 BOD5 99.77 COD 266.74 Ntot 32.36 N-NH4+ 18.77 Ptot 3.79 Al 1.56 Cr 0.10 Fe 0.94 Pb 0.01 7.3.3. Strategy of operation The reactor was operated during the two modes of operation with a hydraulic retention time (HRT) of 1.25 days. The SBR was operated in cycles of 6 hours including a feeding phase of 30 min, a reaction phase of 300 min (90 anoxic, 210 aerobic), a settling period of 37 min and an effluent withdrawal period of 23 min (Figure 7.5). 7-13 A membrane coupled to a SBR for water reuse and removal of coliform bacteria Fill Anoxic reaction Aerobic reaction Settle Withdrawal Time (minutes) 3 0 90 210 37 23 Figure 7.5. Cycle distribution for the SBRs operation. 7.3.4. Analytical methods The pH, nitrate, ammonia, total nitrogen, volatile suspended solids (VSS), total suspended solids (TSS) and COD were determined according to Standard Methods (APHA, 1999) as described in Chapter 2. Microbiologic analysis Faecal coliforms and Escherichia Coli were measured by a membrane filtration technique combined with selective growth on C-EC Agar. Results are expressed as Coliform Forming Units (CFU) in 100 mL/sample (Isra-Cnr, 1994) (Chapter 2). E. Coli was enumerated from faecal coliforms by using the wood Lamp. 7.3.5. Determination of critical and maximum flux Critical and maximum fluxes were determined by monitoring the TMP according to the procedure suggested by Kwon (Kwon et al., 2000). This method is based on the increase in TMP required to maintain a constant permeate flux. The TMP increases during the constant permeate flux operation in order to compensate the increase in the resistance to permeation. The critical flux is the flux below which there is no presence of this increase in resistance to permeation (i.e. the TMP is constant with time). Thus, there will be no increase in the TMP with time if no or negligible membrane fouling occurs. On the other hand, the increase in TMP implies that the cake layer formed by deposited particles caused significant resistance to permeate flow (fouling effect). 7-20 Chapter 7 7.5 g VSS/L 0 10 20 30 40 50 60 0 20406080100120140 t (min) L/(m2.h) 0 100 200 300 400 500 600 700 800 TMP (mbar) 11 g VSS/L 0 10 20 30 40 50 60 0 20406080100120140 t (min) L/(m2.h) 0 200 400 600 800 1000 1200 TMP (mbar) 2.5 g VSS/L 0 10 20 30 40 50 60 0 20 40 60 80 100 120 140 t (min) L/(m2.h) 0 20 40 60 80 100 120 140 TMP (mbar) 5 g VSS/L 0 10 20 30 40 50 60 0 20 40 60 80 100 120 140 t (min) L/(m2.h) 0 50 100 150 200 250 300 350 TMP (mbar) 0 g VSS/L 0 10 20 30 40 50 60 0 20406080100120140 t (min) L/(m2.h) 0 20 40 60 80 100 120 140 TMP (mbar) Figure 7.12. Variation of TMP with time under stepwise increments of permeate flux to different VSS concentrations ( TMP,  L/(m2.h)) 7-21 A membrane coupled to a SBR for water reuse and removal of coliform bacteria 7.4.3 Two configurations Both configurations: (i) a membrane coupled to a SBR (MSBR) with intermittent permeate extraction and (ii) a membrane bioreactor (MBR) with continuous permeate extraction, were used to monitor their performances at equal daily flow permeate extraction. The two reactors were inoculated with 2.5 g VSS/L from 20 L SBR. The main operational stages of the reactors were (Figure 7.13): a) First period (0-10,000 min) Although the operation of the MSBR was satisfactory during first cycles (TMP was maintained constant around 150 mbar ) to a flux of 35 L/(h·m2) with withdrawal time of 1 h/d, after 4,000 min the TMP was increased along the withdrawal time and subsequently fouling was reached. Chemical cleaning of the membrane was necessary. The MBR was operated continually with a flow of 1.5 L/(h·m2) and TMP was maintained constant (<50 mbar) during the entire operation, except when the flow was increased drastically. b) Second period (10,000-20,000 min) The withdrawal time was increased to 4 h/d, decreasing the flux to 8.5 L/(h·m2) and the operation of the MSBR was stable (TMP = 70 mbar). The MBR was also stable at the same flux. c) Third period (20,000-30,000 min) The withdrawal time was maintained and the flow was increased to 28 L/(h·m2) in the MSBR and MBR. The operation of the membranes was satisfactory. Optimal conditions were reached to operate the MSBR and the MBR. 7-22 Chapter 7 MSBR 0 100 200 300 400 500 0 5000 10000 15000 20000 25000 30000 t (min) TMP (mbar) 0 5 10 15 20 25 30 35 40 Flux (L/h.m2) MBR 100 200 300 400 500 0 5000 10000 15000 20000 25000 30000 t (min) TMP (mbar) 0 5 10 15 20 25 30 35 40 Flux (L/h.m2) Figure 7.13. Operation of MSBR and MBR (• TMP; U L/(m2.h)) 7-23 A membrane coupled to a SBR for water reuse and removal of coliform bacteria 7.5. Conclusions The presented work illustrates that membrane technology has a significant potential to become a key element of wastewater reclamation and reuse schemes world-wide. Membranes for municipal wastewater treatment feature advantages compared to conventional activated sludge plants in terms of effluent quality, reflected in lower values for organics, nutrients and microorganisms. Results demonstrated that the removal efficiency of both bacteria and suspended solids by membrane filtration was 100%, suggesting that the experimented compact system (SBR+membrane filtration) could produce an effluent suitable for reuse in agriculture and could be a suitable technology for rural communities. The membrane process coupled with a SBR not only replaces the sedimentation period in the operation of a SBR but also serves as an advanced treatment unit for coliform bacteria and suspended solids, which cannot be removed completely by conventional processes. The operation of two configurations, a membrane coupled to a SBR and a MBR, were satisfactory to operate the system to the optimal hydraulic conditions. 7.6. References APHA-AWWA-WPCF. (1999). Standard Methods for the examination of water and wastewater. 20th Edition. Clesceri, L.S., Greenberg, A.E. & Eaton, A.D. (eds.). Bacchin P., Aimar P. and Sanchez V. (1995). Model for colloidal fouling of membranes. AICHE Journal, 41 (2), 368-376. Banas J., Plaza E., Styka W. and Trela J. (1999). SBR technology used for advanced combined municipal and tannery wastewater treatment with high receiving water standards. Water Science and Technology, 40 (4-5), 451-8. Bixio D., Thoeye C., De Koning J., Joksimovic D. Savic D., Wintgens T. and Melin T. (2006). Wastewater reuse in Europe. Desalination, 187, 89-101. Buisson H., Cote P., Praderie M. and Paillard H. (1998). The use of immersed membranes for upgrading wastewater treatment plants. Water Science and Technology, 37 (9), 89-95. 7-24 Chapter 7 Cho B. D. and Fane A.G. (2002). Fouling transients in nominally sub-critical flux operation of a membrane bioreactor. Journal of Membrane Science, 209 (2), 391-403. Cicek N., Winnen H., Suidan M.T., Wrenn B.E., Urbain V. and Manem J. (1998). Effectiveness of the membrane bioreactor in the biodegraddation of high molecular weight compounds. Water Research, 32, 1553-1563. Côté P., Mourato D., Güngerich C., Russell and Houghton E. (1998). Inmersed membrane filtration for the production of drinking water: Cases studies. Desalination, 117, 181-188. Countil Directive of 8 December 1975 (1975). Concerning the Quality of Bathing Water, Official. J. Eur. Commun., L31. Countil Directive of 21 May 1991 (1991). Concerning Urban Waste Water Treatment, Official J.Eur. Commun., L135. Decree of Environmental Ministry 185/2003. Italian Legislation. Legge quadro sulle acque D. Legs 152/99; Decreto nº 185 12/6/2003. EPA. (1999). Wastewater technology fact sheet sequencing batch reactor. Office of Water, United States Environmental Protection Agency, Washington DC. Ficara E., Rocco, A. And Rozzi A. (2000). Determination of nitrification kinetics by the ANITA-DOstat biosensor. Water Science Technology, 41 (12), 121- 128. Field R.W., Wu D., Howell J.A. and Gupta B.B. (1995). Critical flux concept for microfiltration fouling. Journal of Membrane Science, 100, 259-272. Gander M., Jefferson B. and Judd S. (2000). Aerobic MBRs for domestic wastewater treatment: a review with cost considerations. Separation and Purification Technology, 18, 119-130. Günder B. and Krauth K. (1999). Repplacement of secondary clarification by membrane separationresults with tubular, plante and hollow fibre modules. Water Science and Technology, 40 (4-5), 311-320. Hochstrat R. and Wintgens T. (2003). Draft of wastewater reuse potential estimation, Interim report. Eds. AQUAREC, report on Milestone M3.1. 7-25 A membrane coupled to a SBR for water reuse and removal of coliform bacteria Howell J.A. (1995). Sub-critical flux operation of microfiltration. Journal of Membrane Science, 107, 165-171. Irvine R.L., Wilderer P.A. and Flemming H.C. (1997). Controlled unsteady state processes and technologies-an overview. Water Science and Technology, 35, 1-10. Isra-Cnr (1994). “Metodi analitici per le Acque”. Judd S.J. (2004). A review of fouling of membrane bioreactor in sewage treatment. Water Science and Technology, 49 (2), 229-235. Kang I.J., Lee C.H. and Kim K.J. (2003). Characteristics of microfiltration membranes in a membrane coupled sequencing batch reactor system. Water Research, 37, 1192-1197. Ketchum Jr. LH. (1997). Design and physical features of sequencing batch reactors. Water Science and Technology, 35 (1), 11-8. Kishino H., Ishida H., Iwabu H. and Nakano I. (1996). Domestic wastewater reuse using a submerged membrane bioreactor. Desalination, 106, 115-119. Krampe J. and Krauth K. (2000). Sequencing batch reactor with submerged hollow fibre membranes for the biomass separation. In: Proceedings of 2nd international symposium on sequencing batch reactor technology, 2, 109-15. Kwon D.Y., Vigneswaran S., Fane A.G., Ben Aim R. (2000) Exprimental determination of critical flux in cross-flow microfiltration. Separation and Purification, 19, 169-181. Larsen T. and Harremoes P. (1994). Degradation mechanisms of colloidal organic matter in biofilm reactors. Water Research, 28 (6), 1443-1452. Melin T., Jefferson B., Bixio D., Thoeye C., De Wilde W., De koning J., van der Graaf J. And Wontgens T. (2006). Membrane bioreactor technology for wastewater treatment and reuse. Desalination, 178, 271-282. Ognier S., Wisniewski C. and Grasmick A. (2004). Membrane bioreactor fouling in sub-critical filtration conditions: a local critical flux concenpt. Journal of Membrane Science, 229 (1-2), 171-177. 7-26 Chapter 7 Pavelj N., Hvala N., Kocijan J., Ro M., Ubelj M., Mui G. and Strmnik S. (2001). Experimental design of an optimal phase duration control strategy used in batch biological wastewater treatment. ISA Transactions, 40 (1), 41-56. Pochana K. and Keller J. (1999). Study of factors affecting simultaneous nitrification and denitrification (SND). Water Science and Technology, 39 (6), 61-8. Schleypen P., Michel I. and Siewert H.E. (1997). Sequencing batch reactors with continuous inflow for small communities in rural areas in Bavaria. Water Science and Technology, 35 (1), 269-276. Stephenson T., Judd S.J., Jefferson B. and Brindle K. (2000). Membrane Bioreactors for Wastewater Treatment. IWA Publishing, London. Tyszler D., Zytner R..G., Batsch A., Brügger A., Geissler S., Zhou H., Klee D. and Melin T. (2006). Reduced fouling tendencies of ultrafiltration membranes in wastewater treatment by plasma modification. Desalination, 189, 119-129. Ueda T., Hata K. and Kikuola Y. (1996). Treatment of domestic sewage from rural settlements by a membrane bioreactor. Water Science Technology, 34 (9), 189-196. Ueda T. and Hata K. (1999). Domestic wastewater treatment by a submerged membrane bioreactor with gravitational filtration. Water Research, 33 (12), 2888-2892. Ueda T. and Horan N.J. (2000). Fate of indigenous bacteriaphage in a membrane bioreactor. Water Research, 34, 2151-2159. Wei Chunhai, Huang Xia and Wen Xianghua (2006). Pilot study on municipal wastewater treatment by a modified submerged membrane bioreactor. Water Science and Technology, 53 (9), 103-110. C-1 Conclusions The main conclusions of this research were to assay and develop different alternatives for the improvement of the biological treatment stage of wastewater treatment plants. Here these are summarised and presented. Sequencing Batch Reactors (SBRs) were employed to generate and to study the performance of aerobic, nitrifying and Anammox granules in order to improve the nitrogen removal from wastewater. The influence of different parameters (shear stress, biomass selection by means of the settling rate, the type of substrate, COD, N-load and oxygen concentration) in the formation of aerobic/nitrifying/Anammox granules in SBRs was studied. The formation of aerobic granules in two SBRs was achieved by using an industrial wastewater coming from a dairy analysis laboratory and synthetic wastewater as influent. Granules with good settling properties were obtained, SVI of 60 mL/g VSS, and ZSV of 20 m/h. This made feasible to operate the system with high exchange volume and thus organic and nitrogen loading rates applied to both systems were high, up to 7 g COD/(L·d) and 0.7 g NH4+-N/(L·d). Nitrogen removal efficiency was similar in both units, even considering that R2 was operated always under aerobic conditions. Nitrogen and COD removal efficiencies were 80 and 70 %, respectively. Nitrate disappeared in both units during the first minutes of the feeding period, although in R2 dissolved oxygen concentration was higher than 3 mg O2/L. Thus, denitrification might take place in R2 in the inner core of the granules, oxygen being depleted by the outer layers. It was found that the presence of TSS in the effluent was a result of at least of three causes: the own presence of TSS in the influent; the detachment of small biomass patches from the granules and the growth of small flocs that were washed C-8 Conclusiones efluente apto para su reutilización en agricultura y podría ser una tecnología apropiada para comunidades rurales. El sistema de membrana acoplado a un SBR no sólo reemplaza el período de sedimentación sino que también sirve como una unidad de tratamiento avanzado para la eliminación de bacterias coliformes y sólidos en suspensión, los cuales no se pueden eliminar totalmente con los sistemas de tratamiento convencionales. Resumiendo, las nuevas tecnologías (gránulos aerobios, nitrificantes y Anammox) han mostrado ser muy eficientes en la eliminación de nutrientes y son apropiadas para el tratamiento tanto de aguas municipales como industriales. Gránulos de un tamaño considerable se han obtenido en los diferentes reactores y se han operado de forma estable durante varios meses. El estudio de las fuerzas de estrés, la configuración del reactor y otros parámetros contribuyeron a mejorar la estabilidad del proceso. Por último, el uso de la tecnología de membranas permitió obtener un efluente con alta calidad en términos de materia orgánica, sólidos en suspensión y bacterias coliformes, lo cual permite la reutilización directa de las aguas residuales. C-9 Conclusións Preséntanse aquí as conclusións xerais deste traballo de investigación, no que se avaliaron e desenrolaron diferentes alternativas para a mellora do tratamento biolóxico das augas residuais. Empregáronse reactores SBRs (Sequencing Batch Reactors) para a obtención e o estudio do comportamento dos gránulos aerobios, nitrificantes e Anammox e así estudiar a eliminación de altas concentracións de nitróxeno da auga residual. Estudiouse a influencia de diferentes parámetros (forzas de estres, selección da biomasa a través da velocidade de decantación, tipo de substrato, DQO, carga de nitróxeno e concentración de osíxeno) na formación de gránulos aerobios, nitrificantes e Anammox. Obtivéronse gránulos aerobios en dous SBRs, tanto usando como influente auga sintética como auga industrial procedente dun laboratorio de análise de productos lácteos. Estes gránulos tiñan boas propiedades de sedimentación, índice volumétrico de lodos de 60 mL/g SSV e velocidade de sedimentación de 20 m/h. Esto fixo posible operar o sistema con alto porcentaxe de intercambio e con altas velocidades de carga orgánica (VCO) e nitroxenada (VCN) alcanzándose valores de 7 g DQO/(L·d) e 0,7 g NH4+-N/(L·d), respectivamente. Os porcentaxes de eliminación de nitróxeno foron similares nos dous reactores, incluso considerando que o R2 operouse sempre en condicións aerobias. A eficacia de eliminación de nitróxeno e de DQO foi de 80 e 70%, respectivamente. O nitrato desapareceu nos dous sistemas durante os primeiros minutos da alimentación, a pesar de que en R2 a concentración de osíxeno foi sempre superior a 3 mg O2/L. Esto foi debido a que a desnitrificación tivo lugar no interior do gránulo donde o osíxeno non penetrou. C-10 Conclusións Atopouse que a presencia de sólidos en suspensión totais (SST) no efluente dos reactores podía ser un resultado de polo menos tres causas: a propia presencia de SST no influente, o desprendemento de pequenas partículas de biomasa do gránulo e o crecemento de pequenos flóculos os cales lavábanse do sistema. A presencia de SST no efluente dos SBRs estivo relacionada tanto ca lonxitude dos períodos de vertido como ca relación DQO particulada/sólidos en suspensión volátiles (DQO/SSV) aplicada ó sistema. Obtivéronse gránulos nitrificantes facilmente partindo dos gránulos heterótrofos nos que se producían os procesos de nitrificación e desnitrificación eliminando a fonte de carbono da alimentación. Encontrouse que a relación DQO/N influenciou a composición do efluente, xa que co cambio de DQO/N tamén cambiaban os procesos que se levan a cabo no interior do gránulo. Relacións DQO/N maiores a 5 producían os maiores porcentaxes de eliminación de nitróxeno. Estudiouse tamén a influencia das condicións hidrodinámicas (forzas de estres e configuración do reactor) sobre o proceso de granulación nun SBR con unha xeometría de altura/diámetro (H/D) de 2,5. Obtivéronse gránulos con boas propiedades de sedimentación, índice volumétrico de 30-40 mL/g SSV, e velocidade de sedimentación maior de 8 m/h. A formación de gránulos estables non foi posible para VCO menores de 1 g DQO/L·d, o que implica que se necesita unha mínima cantidade de materia orgánica para xerar biomasa granular. Comparado co proceso de lodos activos, en donde a sedimentación ten lugar nun decantador separado do reactor, o lodo granular requiro só un 20-30% do espacio en relación as plantas convencionais, o cal implica unha reducción de costes. Tamén serán menores os requirimentos enerxéticos, poderase aforrar en torno a un 30-40% usando un sistema granular. Estudiouse tamén o efecto das condicións hidrodinámicas de operación sobre o proceso Anammox en un SBR, en donde a mixtura completa alcanzouse usando un axitador mecánico ou por fluxo de gas. Á vista dos resultados obtidos, pódese concluír que o proceso Anammox presenta unha alta capacidade para soportar alto estres subministrado pola axitación mecánica ou polo fluxo de gas. C-11 Conclusións O proceso Anammox levouse a cabo correctamente traballando cunha potencia específica comprendida entre 0,003 e 0,09 kW/m3 (ata 180 rpm) para o reactor axitado mecanicamente e de 0,003 e 0,057 kW/m3 (a 5.29 cm/min) para o reactor axitado por gas. Sen embargo, cando a velocidade de axitación incrementouse a 250 rpm e o fluxo de gas a 7,4 cm/min, o que implicou 0,23 kW/m3 e 0,075 kW/m3, respectivamente obtívose unha reducción da estabilidade do proceso. Esta reducción da estabilidade afectou principalmente á actividade específica Anammox e á retención da biomasa no sistema. A actividade Anammox diminuíu considerablemente, o que provocou unha perdida de eficiencia do sistema debido a combinación de lise celular e a rotura dos gránulos. A retención da biomasa empeorou como consecuencia da rotura dos gránulos e a flotación que estivo causada pola acumulación de nitrito. Sen embargo, durante este período os gránulos foron máis compactos e a densidade dos mesmos tamén aumentou. Para a operación a escala industrial dun SBR deberase realizar un control das forzas de estres para que o proceso Anammox lévese a cabo de forma estable. Estas forzas afectan á actividade do sistema Anammox só no caso de aplicar un alto estres. É importante subliñar que a actividade, o tamaño dos gránulos e a estabilidade do proceso recuperouse unha vez que volveu o estres inicial aplicado ó sistema. O presente traballo demostrou que a tecnoloxía de membranas ten unha gran importancia para chegar a ser un elemento clave para o tratamento e a reutilización de augas. As membranas presentan grandes vantaxes para o tratamento de augas residuais urbanas comparadas cos sistemas tradicionais de depuración de augas. Entre estas vantaxes subliñar, a alta calidade do efluente reflexada en valores moi baixos de compostos nitroxenados, nutrientes e microorganismos. Os resultados obtidos demostraron que a eficacia de eliminación de bacterias e sólidos en suspensión en sistemas de membranas foi dun 100%, o cal indica que o sistema compacto (SBR + membrana) pode producir un efluente apto para a súa reutilización na agricultura e podería ser unha tecnoloxía apropiada para comunidades rurais. O sistema de membrana acoplado a un SBR non só C-12 Conclusións reemplaza o período de sedimentación senón que tamén serve como unha unidade de tratamento avanzado para a eliminación de bacterias coliformes e sólidos en suspensión, os cales non se poden eliminar totalmente cós sistemas de tratamento convencionais. Resumindo, as novas tecnoloxías (gránulos aerobios, nitrificantes e Anammox) mostraron ser moi eficientes na eliminación de nutrientes e son apropiadas para o tratamento tanto de augas municipais como industriais. Obtivéronse gránulos dun tamaño considerable nos diferentes reactores e operáronse de forma estable durante varios meses. O estudio das forzas de estres, a configuración do reactor e outros parámetros contribuíron a mellorar a estabilidade do proceso. Por último, o uso da tecnoloxía de membranas permitiu obter un efluente con alta calidade en termos de materia orgánica, sólidos en suspensión e bacterias coliformes, o cal permite a reutilización directa das augas residuais tratadas. L-1 List of publications 1. Journal papers  Arrojo B., Figueroa M., Mosquera-Corral A., Campos J.L. and Méndez R. (2006). Effects of hydrodynamic conditions and feeding composition on the aerobic granulation in SBRs. (Submitted).  Arrojo B., Vázquez-Padín J.R., Figueroa M., Mosquera-Corral A., Campos J.L. and Méndez R. (2006). Reactores de biomasa granular: Más capacidad en menos espacio. Afinidad. (Submitted).  Vázquez-Padín J.R., Figueroa M., Arrojo B., Mosquera-Corral A., Campos J.L. and Méndez R. (2006) Why do nitrifying granules accumulate nitrite?. (Submitted).  Arrojo B., Figueroa M., Mosquera-Corral A., Campos J.L. and Méndez R. (2006). Effects of hydrodynamic shear forces on Anammox granules. (Submitted).  Campos J.L., Arrojo B., Mosquera-Corral A. and Méndez R. (2006). N2O production by nitrifying biomass under aerobic and anoxic conditions. Applied Biochemistry and Biotechnology. (Submitted).  Arrojo B., Mosquera-Corral A., Campos J.L. and Méndez R. (2006). Effects of mechanical stress on Anammox granules in a sequencing batch reactor (SBR). Journal of Biotechnology, 123, 453-563.  Arrojo B., Mosquera-Corral A., Garrido J.M., Méndez R., Ficara E. and Malpei F (2005). Membrane coupled to a Sequencing Batch Reactor for water reuse and removal of coliform bacteria. Desalination, 179, 109-116.  Arrojo B., Mosquera-Corral A., Garrido J.M. and Méndez R. (2004). Aerobic granulation with industrial wastewater in sequencing batch reactors. . Water Research, 38, 3389-3399.  Dapena-Mora A., Arrojo B., Campos J.L., Mosquera-Corral A. and Méndez R. (2004). Improvement of the settling properties of Anammox sludge in a SBR. Journal of Chemical Technology and Biotechnology, 79, 1417-1420.  Fernández-Carrasco E. Omil F., Garrido J.M., Arrojo B. and Méndez R. (2004). Advanced monitoring and supervision of biological treatment of complex dairy effluents in a full-scale plant. Biotechnology Progress, 20, 992-997.  Arrojo B., Omil F., Garrido J.M. and Méndez R. (2003). Combinación de un filtro anaerobio y un sistema SBR para el tratamiento de las aguas generadas en un laboratorio de análisis de productos lácteos. Afinidad, 60, 344-354.  Omil F., Garrido J.M., Arrojo B., and Méndez R. (2003). Anaerobic filter reactor performance during the treatment of complex dairy wastewaters at industrial scale. Water Research, 37, 4099-4108.  Garrido J.M., Omil F., Arrojo B., Méndez R. and Lema J.M. (2001). Carbon and nitrogen renoval from a wastewater of an industrial dairy laboratory with a coupled anaerobic filter-sequencing batch reactor system. Water Science and Technology, 43, 249-256. L-2 List of publications 2. Book chapters  Mosquera-Corral A., Vázquez –Padín J.R., Arrojo B., Campos J.L. and Méndez R. (2005). Nitrifying granular sludge in a Sequencing Bacth Reactor. Aerobic Granular Sludge. Water and environmental Management series, IWA Publishing, 63-70. 3. Contribution to congress  Vázquez-Padín J.R., Figueroa M., Arrojo B., Mosquera-Corral A., Campos J.L. and Méndez R.. Why do nitrifying granules accumulate nitrite?. Oral presentation. 2nd Aerobic granular sludge Workshop. Delf, The Netherlands. September 2006.  Vázquez-Padín J.R., Figueroa M., Arrojo B., Campos J.L., Mosquera-Corral A. and Méndez R. Tratamiento de efluentes industriales en sistemas de granulación aerobia. Poster. Biospain- BIOTEC 2006. Madrid, Spain. September 2006.  Arrojo B., Mosquera-Corral A., Campos J.L. and Méndez R. Effects of hydrodynamic shear force on Anammox granules. Oral presentation. International Symposium on Environmental Biotechnology ESEB 2006. Leipzig, Germany. July 2006  Arrojo B., Mosquera-Corral A., Campos J.L. and Méndez R. How does stress affect Anammox granulation and performance?. Oral presentation. International Water Conference (IWC’2006). Porto, Portugal. June 2006.  Dapena-Mora A., Trigo C., Fernández I., Vázquez-Padín J.R., Figueroa M., Arrojo B., Garrido J.M., Mosquera-Corral A., Campos J.L. and Méndez R. Startup of Anammox reactors: Different reactor alternatives. Oral presentation. IWA Specialized Conference Nutrient Management in Wastewater Treatment Processes and Recycle Streams. Krakow, Poland. September 2005.  Vázquez-Padín J.R., Arrojo B., Mosquera-Corral A., Figueroa M., Campos J.L. and Méndez R. Granulation sludge for aerobic wastewater treatment: nitrogen renoval. Poster. X Congreso Mediterráneo de Ingeniería Química. Barcelona, Spain. November 2005.  Arrojo B., Mosquera-corral A., Garrido J.M., Méndez R, Ficara E. and Malpei F. Membrane coupled to a sequencing batch reactor for water resuse and removal of coliform bacteria. Oral presentation. Congress on Membranes in Drinking and Industrial Water Production. L’Aquila, Italy. November 2004.  Mosquera-Corral A., Vázquez –Padín J.R., Arrojo B., Campos J.L. and Méndez R. Nitrifying granular sludge in a Sequencing Bacth Reactor. Oral presentation. IWA workshop on Aerobic Granular Sludge. Munich (Germany). September 2004. L-3 List of publications  Arrojo B., Mosquera-Corral A., Campos J.L., Garrido J.M. and Méndez R. Eliminación de nitrógeno en un reactor continuo secuencial granular (SBR). Poster. Congreso Nacional de Biotecnología (BIOTEC’2004). Oviedo, Spain. July 2004.  Arrojo B., Mosquera-Corral A., Campos J.L. and Méndez R. Nitrite production in a granular Sequencing Batch Reactor. Poster. European Symposium on Environmental Biotechnology ESEB 2004. Oostende, Belgium. April 2004.  Arrojo B., Mosquera-Corral A., Garrido J.M. and Méndez R.. Aerobic granulation in a SBR fed with industrial wastewater. Poster. European Symposium on Environmental Biotechnology ESEB 2004. Oostende, Belgium. April 2004.  Arrojo B., Mosquera-Corral A., Campos J.L., Garrido J.M. and Méndez R.. Influence of COD/N ratio on N removal in aerobic granular sludge. Poster. EU 5 th Framework ICON-Anammox 2004 symposium “New sustainable N-removal from wastewater”. Ghent , Belgium. January 2004.  Arrojo B., Mosquera-Corral A., Garrido J.M. and Méndez R. Aerobic granulation in SBR with industrial wastewater. Poster. 4th European Congress of Chemical Engineering. Granada, Spain. September 2003.  Arrojo B., Garrido J.M., Omil F., and Méndez R. Treatment of dairy wastewaters at industrial scale with a coupled anaerobic filter-sequencing batch reactor. Poster. 9th Mediterranean Congress of Chemical Engineering. Barcelona, Spain. November 2002.  Omil F., Garrido J.M., Arrojo B., Pena R., Méndez R. Anaerobic treatment of the effluents discharged by milk analysis laboratories. Poster. 9 th World Congress Anaerobic Digestion 2001. Antwerpen, Belgium. September 2001.  Garrido J.M., Omil F., Arrojo B., Méndez R., Lema J.M. Carbon and nitrogen removal from a wastewater of an industrial dairy laboratory with a coupled anaerobic filter-sequencing batch reactor system. Oral presentation. 2nd International Symposium on Sequencing Batch Reactor Technology. Narbonne, France. July 2000.  S. López, Arrojo B., M. Jull and J.M. Garrido. Treatment of a dairy wastewater in an anaerobic filter. Poster. IV International ANQUE Chemistry Conference Food. Lugo, Spain. September 1998.  Arrojo B., S. López, E. Roca and J.M. Garrido. Treatment of the water of a laboratory for milk analysis in an anaerobic filter. Poster. IV Iberian Congress on Biotechnology, BIOTEC´98. Guimaraes, Portugal. July 1998.