INTERNATIONAL DOCTORAL SCHOOL OF THE USC Lúa Vázquez Ferreiro PhD Thesis Miniaturized extraction techniques coupled to chromatography and tandem mass spectrometry and high resolution mass spectrometry for the determination of organic compounds of agricultural and environmental interest Santiago de Compostela, 2022 Doctoral Programme in Chemical Science and Technology
TESE DE DOUTORAMENTO MINIATURIZED EXTRACTION TECHNIQUES COUPLED TO CHROMATOGRAPHY AND TANDEM MASS SPECTROMETRY AND HIGH RESOLUTION MASS SPECTROMETRY FOR THE DETERMINATION OF ORGANIC COMPOUNDS OF AGRICULTURAL AND ENVIRONMENTAL INTEREST Lúa Vázquez Ferreiro ESCOLA DE DOUTORAMENTO INTERNACIONAL DA UNIVERSIDADE DE SANTIAGO DE COMPOSTELA PROGRAMA DE DOUTORAMENTO EN CIENCIA E TECNOLOXÍA QUÍMICA SANTIAGO DE COMPOSTELA 2022
DECLARACIÓNDOAUTOR/ADATESE D ./ Dna.LúaVázquezFerreiro Títulodatese: Miniaturizedextractiontechniquescoupledtochromatographyandtandemmass spectrometryandhighresolutionmassspectrometryforthedeterminationoforganic compoundsofagriculturalandenvironmentalinterest Presentoamiñatese,seguindooprocedementoaxeitadoaoRegulamento,edeclaroque: 1) Ateseabarcaosresultadosdaelaboracióndomeutraballo. 2) Deserocaso,natesefaisereferenciaáscolaboraciónsquetivoestetraballo. 3) Confirmoqueatesenonincorreenningúntipodeplaxiodoutrosautoresnindetraballos presentadosporminparaaobtencióndoutrostítulos. 4) Ateseéaversióndefinitivapresentadaparaasúadefensaecoincideaversiónimpresacoa presentadaenformatoelectrónico EcomprométomeapresentaroCompromisoDocumentaldeSupervisiónnocasodequeoorixinalnon esteanaEscola. EnSantiagodeCompostela,20deMaiode2022. Asdo.LúaVázquezFerreiro
AUTORIZACIÓN DO DIRECTOR / TITOR DA TESE Miniaturized extraction techniques coupled to chromatography and tandem mass spectrometry and high resolution mass spectrometry for the determination of organic compounds of agricultural and environmental interest Dna. María Llompart Vizoso D. Thierry Dagnac INFORMAN: Que a presente tese, correspóndese co traballo realizado por Dna. Lúa Vázquez Ferreiro, baixo a nosa dirección/titorización, e a utorizamos a súa presentación , considerando que reúne os r equisitos esixidos no R egulamento de Estudos de Doutoramento da USC, e que como director desta non incorre nas causas de abstención establecidas na Lei 40/2015. De acordo co indicado no Regulamento de Estudos de Doutoramento, declara tamén que a presente tese de doutoramento é idónea para ser defendida en base á modalidade de COMPENDIO DE PUBLICACIÓNS , nos que a participación da doutoranda foi decisiva para a súa elaboración e as publicacións se axustan ao Plan de Investigación. En Santiago de Compostela 20 de maio de 2022 Asdo.MaríaLlompartVizosoAsdo.ThierryDagnac
AGRADECEMENTOS En primeiro lugar quero agradecer aos meus directores, María e Thierry, pola oportunidade que me deron para poder realizar esta tese doutoral. Gracias María, polo apoio e a esixencia do día a día para poder alcanzar metas. Gracias tamén a Thierry, pola incondicional axuda, aínda que case sempre fose a través do correo. Gracias a todos os compañeiros de LIDSA. A María C, por estar sempre para botar unha man e ser o pilar fundamental do grupo, non sei que faríamos sen ti! Gracias tamén aos doutorandiños, por resolver problemas xuntos e apoiarnos mutuamente. Laura, gracias por axudar en todo o que podes e máis. Gracias Aly por ser tan resolutivo e comprenderme tomando café con leite en polvo. Tamén a Miguel, que por fin te vas librar de que ande detrás túa en busca das chaves. Gracias a Marta e Carmen, por transmitirme o voso coñecemento e polos bos momentos nos cafés. Tamén quería agradecer a todos os que foron pasando polo laboratorio ao largo destes anos que aportaron un pouquiño nesta tese: Tamara, Ángeles, Perla, Rocío... Gracias especialmente a: Ana porque a veces me vexo reflexada en ti e porque espero que sexas o futuro do LIDSA; Helena gracias por transmitirme a túa constancia e paciencia; Santi M. por entenderme tan ben, especialmente na túa última etapa no grupo; e a Santi D. por aguantarme tanto, oxalá puidera traballar man a man contigo sempre! I would also like to thank Mika, for all the work we have done together, and Pi, for the joy you transmit and for offering your help even from thousands of kilometres away. Quero agradecer ao Departamento de Química Analítica, Nutrición e Bromatoloxía por acollerme durante estes anos. Tamén a CRETUS, Xunta de Galicia, COST Action 16215 e ao programa IACOBUS pola financiación para os contratos, proxectos e estancias.
Thanks to Prof. Elia Psillakis from the Technical University of Crete, Greece, for giving me the opportunity to participate in the research stay in her laboratory and for transmit her enthusiasm for research. Thanks also to all the people I met in Chania who allowed me to spend a wonderful month there. Gracias ao Dr. Vítor Vilar, por acollerme durante dous meses no seu grupo de investigación na Universidade do Porto, Portugal, e introducirme un pouquiño máis no mundo da enxeñaría. Un enorme gracias a Ana, por ser literalmente o meu terceiro brazo e a miña segunda cabeza durante dous meses. Gracias ao resto do grupo que me axudaron a levar a cabo todo o traballo: Lúcio, Pedro... Tamén quero agradecerlle a Miguel todo o traballo que leva feito comigo para orientarme. Se non fose por ti, creo que estaría máis perdida que o primeiro día que a empecei. Por suposto gracias a Gorety por acompañarme desde sempre e apoiarnos en todo. Tamén a Laura e Tania, a pesar da distancia. Infinitas gracias a Mónica por entenderme mellor que ninguén, escoitar as miñas queixas e aconsellarme sempre. Gracias tamén a Darío, especialmente por valorar tanto o esforzo na redacción dos artigos. Gracias ao FUS, demais amigos e familia. En especial, quero darlle as gracias a meus pais porque sen vós non chegaría onde estou; a Uxía e a Chechu por entenderme cando sempre digo que non teño tempo porque non dou para máis; e a miña avoa por animarme en todo aínda que non entenda ben o que fago. Por último, un millón de gracias a Dani por absolutamente todo. Por apoiarme, axudarme e aguantarme dentro e fóra do laboratorio. Sen ti esta tese non tería sentido.
Index 5.2.1. Introduction 67 5.2.2. Mass spectrometry 68 5.3. LIQUID CHROMATOGRAPHY (LC) 70 5.3.1. Introduction 70 5.3.2. Mass spectrometry 71 5.3.3. High-resolution mass spectrometry (HRMS) 71 5.4. UV-VIS SPECTROSCOPY 73 5.4.1 Total Phenolic Content and Antioxidant Activity 73 REFERENCES 77 III. Methodology 101 CHAPTER 1. DETERMINATION OF FUNGICIDES IN AGRICULTURAL AND ENVIRONMENTAL SAMPLES 109 Fabric phase sorptive extraction for the determination of 17 multiclass fungicides in environmental water by gas chromatographytandem mass spectrometry 113 Turning cork by-products into smart and green materials for solidphase extraction - gas chromatography tandem mass spectrometry analysis of fungicides in water 115 Occurrence of fungicides in vineyard and the surrounding environment 117 CHAPTER 2. CHARACTERIZATION OF HONEY: VOLATILE, SEMIVOLATILE AND PHENOLIC COMPOUNDS 119 Optimization of a miniaturized solid-phase microextraction method followed by gas chromatography mass spectrometry for the determination of twenty four volatile and semivolatile compounds in honey from Galicia (NW Spain) and foreign countries 123 Evaluating the presence and contents of phytochemicals in honey samples: phenolic compounds as indicators to identify their botanical origin 125
LÚA VÁZQUEZ FERREIRO CHAPTER 3. DETERMINATION OF PERSONAL CARE PRODUCTS (PCPS) IN COSMETIC FORMULATIONS 127 Miniaturized matrix solid-phase dispersion for the analysis of ultraviolet filters and other cosmetic ingredients in personal care products 131 Development of a solid phase microextraction gas chromatography tandem mass spectrometry methodology for the analysis of sixty personal care products in hydroalcoholic gels ˗ hand sanitizers ˗ in the context of COVID-19 pandemic 133 CHAPTER 4. DETERMINATION OF ANTIBIOTICS IN WATER AND DEGRADATION STUDIES 135 Complementarity of two approaches based on the use of Quadrupole Time-of-Flight High-Resolution Mass Spectrometry for the determination of multi-class antibiotics in wastewater and natural waters. Photodegradation studies and non-targeted screenings 139 Tube-in-tube membrane photoreactor for antibiotic removal from urban wastewater 191 V. General Discussion 221 VI. Conclusions 241 Annex I: List of Publications 249 Annex II: Journal Permissions 257 Annex III: Index of figures and tables 265 Annex IV: Resumo 273
ABBREVIATIONS
Abbreviations iii _______________________________________________________# µMSPD: micro-matrix solid-phase dispersion 2EHMC: 2-ethylhexylmethoxycinnamate 4MBC: 4-methoxybenylidene camphor _______________________________________________________A A: absorbance AA: antioxidant activity ACN: acetonitrile ANOVA: analysis of variance AOPs: advanced oxidation processes APCI: atmospheric pressure chemical ionization Azi: azithromycin _______________________________________________________B bbCID: broadbant collision-induced dissociation BBP: benzylbutylphthalate BHA: butylhydroxyanisole BHT: butylhydroxytoluene BMDM: butyl methoxy dibenzoyl methane BP3: benzophenone-3 BS: benzyl salicylate BuP: butylparaben BzP: benzylparaben
LÚA VÁZQUEZ FERREIRO iv _______________________________________________________C CAS: Chemical Abstracts Service CE: collision energy CECs: contaminants of emerging concern Ceph: cephalexin Cipro: ciprofloxacin Clar: clarithromycin Clar-D3: clarithromycin-D3 _______________________________________________________D DBP: dibutyl phthalate DCHP: dicyclohexyl phthalate DEA: diethyl adipate DEHA: di-2-(ethylhexyl) adipate DEHP: di-2(ethylhexyl) phthalate DEP: diethyl phthalate DHHB: diethylaminohydroxy benzoyl hexyl benzoate DIA: data independent acquisition DIBP: diisobutyl phthalate DIHP: diisoheptyl phthalate DIPP: diisophentyl phthalate DMA: dimethyl adipate DMEP: dimethoxyethyl phthalate
ABSTRACT
Abstract xv The present thesis is focused on the development and optimization of analytical methodologies for the determination of organic compounds of agronomic and environmental interest, as well as pharmaceuticals and personal care products. For this purpose, different miniaturized extraction techniques followed by analysis using different types of chromatography and mass spectrometry, including tandem mass spectrometry and high-resolution mass spectrometry, have been used. The presence of different volatile, semi-volatile and phenolic compounds in honey samples, responsible for organoleptic and nutritional properties, has been studied. In the environmental and health fields, fungicides have been determined in different environmental compartments and crops, as well as antibiotics in wastewaters and natural waters. The degradation of antibiotics employing different approaches, including photodegradation and advanced oxidation processes (AOPs), have been also assessed. On the other hand, the study of personal care products (PCPs), also considered to be emerging pollutants in the environment, has been carried out in cosmetic products and hydroalcoholic gels. The report is divided in six sections. The first is Section I JUSTIFICATION AND OBJECTIVES, which highlights the relevance of the selected analytes and samples, as well as the importance of developing new analytical methodologies for their determination. Section II INTRODUCTION describes the studied substances and matrices, followed by an explanation of the different analytical and extraction techniques employed. Section III METHODOLOGY includes the description of the sample preparation and analytical techniques for the different analytes and matrices. Section IV RESULTS AND DISCUSSION contains the experimental work carried out during this thesis and the obtained results. Nine different works, of which seven are already published, one is under review for publication and other is prepared for submission, are summarized in four chapters, and presented in this section:
LÚA VÁZQUEZ FERREIRO xvi Chapter 1. DETERMINATION OF FUNGICIDES IN AGRICULTURAL AND ENVIRONMENTAL SAMPLES This chapter comprises three publications dealing with the analysis of seventeen fungicides by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). The first two address the development of two analytical methods for the determination of these compounds in water. In the first one, a method based on fabric phase sorptive extraction (FPSE) is presented and in the second one, the solid-phase extraction (SPE) technique is optimized using cork by-products as a green sorbent. In the third article, the development of an ultrasound assisted extraction (UAE) method for the analysis of fungicides in grape leaves is carried out. In addition, the presence of these compounds in grapes and in the related environmental compartments (soil and water) is also assessed. In all cases, the developed methodologies are extensively validated and applied to real samples, and the observed concentration levels are compared with those included in the legislation in force. Chapter 2. CHARACTERIZATION OF HONEY: VOLATILE, SEMIVOLATILE AND PHENOLIC COMPOUNDS This chapter includes two articles. The first one is based on the miniaturization of solid-phase microextraction (SPME) to determine volatile and semi-volatile compounds in honey samples from Galicia and foreign countries by gas chromatography-mass spectrometry (GCMS). Regarding the second one, a characterization of the content of phenolic compounds in Galician honeys of different botanical origin is carried out, with the aim of identifying possible chemical markers. All honeys fell under the umbrella of the Protected Geographical Identification (PGI) of Galicia, the only Spanish PGI that currently exists for honey. Analytical determinations are conducted by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). In addition, indexes such as total phenolic content (TPC) and antioxidant activity (AA) are evaluated using ultraviolet-visible (UV- Vis) spectrophotometry.
Abstract xvii Chapter 3. DETERMINATION OF PERSONAL CARE PRODUCTS (PCPs) IN COSMETIC FORMULATIONS This chapter includes two publications. In the first one, a miniaturized method based on micro-matrix solid-phase dispersion (μMSPD) is developed to determine UV filters in samples of different nature. The method is validated and extended to other families of cosmetic ingredients such as fragrance allergens, preservatives, plasticizers and synthetic musks. The second article deals with the development of a SPME method for the simultaneous extraction of personal care products (PCPs), including fragrance allergens, synthetic musks, preservatives and plasticizers, in hydroalcoholic gels, a cosmetic product of great importance in the current context of COVID-19 pandemic, and which demand has exponentially increased worldwide. In the two publications, analyses are carried out by GC-MS/MS. Chapter 4. DETERMINATION OF ANTIBIOTICS IN WATER AND DEGRADATION STUDIES This chapter includes two works. The first one is an article (under review) based on the optimization of a SPE method for the extraction of antibiotics in wastewater (urban and hospital) and natural water (river and well water) using ultra-high performance liquid chromatography (UHPLC) coupled to quadrupole time-of-flight highresolution mass spectrometry (QToF-HRMS). The target analysis includes fourteen compounds belonging to different families of antibiotics such as macrolides, cephalosporins, fluoroquinolones, sulfonamides and diaminopyrimidines. In addition, a non-target analysis is carried out and other drugs, pesticides, personal care products and metabolites can be identified in the samples. On the other hand, a preliminary photodegradation study using UVC radiation is carried out. In the second work the operational conditions of a tube-in- tube membrane reactor are optimized for the removal of the fourteen antibiotics in urban wastewater. This reactor is based on AOPs, characterized by the generation of highly reactive oxidizing species. In both investigations, a detailed search of possible by-products formed after degradation processes are included.
LÚA VÁZQUEZ FERREIRO xviii Section V GENERAL DISCUSSION comprises a joint discussion of all the works included in the present thesis and, finally, Section VI CONCLUSIONS contains the general conclusions drawn from all the studies carried out.
I. Justification and objectives 5 and principal component analysis (PCA), to allow the classification of honeys according to their botanical origin (Section IV, Chapter 2, 2.2). Finally, pharmaceutical and personal care products (PPCPs), one of the most important groups of organic emerging contaminants, were analysed. Furthermore, their presence in cosmetic formulations is also a matter of concern due to their adverse health effects and propensity to be a source of environmental pollution. Thus, the objectives regarding the analysis of PPCPs can be listed as follows: V. Development of methods to determine personal care products (PCPs) such as fragrance allergens, synthetic musks, preservatives, plasticizers and UV filters in cosmetic formulations by gas chromatography-tandem mass spectrometry (GC-MS/MS) and discussion of their compliance with the current legislation. Micro-matrix solid-phase dispersion (µMSPD) is proposed to assess the presence of seventy-eight compounds belonging to all the mentioned families in cosmetic samples of different nature (Section IV, Chapter 3, 3.1). In the context of the COVID-19 pandemic, the analysis of hydroalcoholic gels deems necessary. Therefore, a method based on solid-phase microextraction (SPME) is optimized for the determination of sixty PCPs including fragrance allergens, synthetic musks, preservatives and plasticizers (Section IV, Chapter 3, 3.2). VI. Determination and degradation of antibiotics in water and non-target analyses by ultra-high-performance liquid chromatography coupled to quadrupole time-of-flight high resolution mass spectrometry (UHPLC-QToF). Optimization of a method based on solid-phase extraction (SPE) to determine fourteen antibiotics, including macrolides, cephalosporins, fluoroquinolones, sulfonamides and
LÚA VÁZQUEZ FERREIRO 6 diaminopyrimidines in wastewater and natural waters and implementation of non-target analyses by high resolution mass spectrometry (HRMS) (Section IV, Chapter 4, 4.1). Due to the presence of not degraded antibiotics after wastewater treatment, a preliminary study of photodegradation by UVC radiation is carried out. In addition, the use of a new approach based on tube-in-tube membrane reactor as an advanced oxidation process (AOPs) is proposed for antibiotics removal. The identification of possible by-products after degradation processes is also performed (Section IV, Chapter 4, 4.1 and 4.2).
II. INTRODUCTION
II. Introduction 11 1. FUNGICIDES 1.1 INTRODUCTION Pesticide is defined by the European Commission as “something that prevents, destroys, or controls a harmful organism ('pest') or disease, or protects plants or plant products during production, storage and transport”. There is a wide variety of pesticides, and different families can be distinguished according to the organism on which they act, such as herbicides, insecticides and fungicides, among many others [1]. Fungicides prevent or eradicate fungal infections on plants or seeds. They have become indispensable for food safety preventing economic damage caused by fungi in different fields as agriculture, horticulture or viticulture. Despite their widespread use, there is public concern about the damage they can cause due to their toxicity both to the environment and to animal and human health [2]. 1.2 CLASSIFICATION Fungicides can be classified according to their active ingredients, including amides, anilinopyrimidines, cloroalkylthiodicarboximides triazoles, morpholines, strobilurins, halogenated substituted monocyclic aromatics, benzimidazoles, among others [2,3]. In addition, the World Health Organization (WHO) also classifies pesticides by their hazard, and the classification is based on the acute oral LD50 in the rat, although dermal toxicity should also be taken into account in some cases. The LD50 is a statistical estimate of the number of mg of toxicant per kg body weight required to kill 50% of a large population of experimental animals. Table 1 includes the studied fungicides in the present thesis, their CAS number, molecular weight
LÚA VÁZQUEZ FERREIRO 12 (MW), structure, and their classification according to their chemical group and their hazard [4]. The data was obtained from ChemSpider (Predicted data is generated using the US Environmental Protection Agency‘s EPISuite™) and chemical structures were made by ChemDraw 20.1.1. Table 1. Fungicides name, CAS number, molecular weight (MW, g mol-1), chemical class, class hazard according to WHO [4] and chemical structure. Name CAS number MW Chemical class Class hazard* Chemical structure Metalaxyl 57837-19-1 279.3 Amide II Cyprodinil 121552-61-2 225.3 Anilinopyrimidine - Tolylfluanid 731-27-1 347.3 Amide U Procymidone 32809-16-8 284.1 Dicarboximide U Folpet 133-07-3 296.6 Chloroalkylthiodicarboximides U Fludioxonil 131341-86-1 248.2 Phenylpyrrole U Myclobutanil 88671-89-0 288.8 Triazole II Kresoxim methyl 143390-89-0 313.3 Strobilurin III Iprovalicarb 140923-17-7 320.4 Amide, carbamate U
II. Introduction 13 Table 1. (cont.) Fungicides name, CAS number, molecular weight (MW, g mol-1), chemical class, class hazard according to WHO [4] and chemical structure. Name CAS number MW Chemical class Class hazard * Chemical structure Trifoxystrobin 141517-21-7 408.4 Strobilurin U Benalaxyl 71626-11-4 325.4 Amide III Fenhexamid 126833-17-8 302.2 Amide U Tebuconazole 80443-41-0 307.8 Triazole II Iprodione 36734-19-7 330.2 Dicarboximide III Pyraclostrobin 175013-18-0 387.8 Strobilurin - Azoxystrobin 131860-33-8 403.4 Strobilurin U Dimethomorph 113210-97-2 387.9 Morpholine III *U: Unlikely to present acute hazard in normal use (LD50 > 5000 mg kg-1); II: Moderately hazardous (LD50 2000-5000 mg kg-1); III: Slightly hazardous (LD50: 50- 2000 mg kg-1)
LÚA VÁZQUEZ FERREIRO 14 However, other parameters can be taken into account to classify fungicides. The mobility is one factor which can determine the type of substance. Non-penetrant fungicides are not absorbed by the plant tissues, so they remain on the surface as a protective barrier. By contrast, penetrant fungicides are deposited on the plant surface and absorbed by leaf tissues. Among penetrant fungicides can be differentiated the systemic (they are transported within the plant) or mesostemic ones (they adhere strongly to the leaf surface and a part of them passes from one side of the leaf to the other) [5]. The mode or mechanism of action (MOA) is the way in which a fungicide molecule inhibits the growth or kills a particular fungus. The Fungicide Resistance Action Committee (FRAC) describes the different MOAs by which fungicides are classified (nucleic acids metabolism, melanin synthesis…) [6]. They can also be differentiated according to the sub-stage of the infectious process in which they are applied, classified as preventive (acting as protectants by preventing infection before fungal spores are deposited), curative (inhibiting fungal growth within plant tissues before symptoms are observed) and eradicating (inhibiting disease progression when symptoms are present) [5]. 1.3 OCCURRENCE IN VINEYARDS AND THE ENVIRONMENT The fungicides studied in the present thesis are usually used in viticulture, since the work is based on vineyards from Galicia (NW Spain), because it is a region with a high wine production in a large part of its territory. Hence, the continuous application of fungicides in vineyards is a matter of public concern, due to the resulting presence of pesticide residues in the environment and in wine products used for human consumption [7]. When fungicides are applied, much of them are not deposited on crops, indicating low application efficacy and high exposure to soil organisms.
II. Introduction 21 Table 3. Volatile and semi-volatiles, CAS number, molecular weight (MW, g mol-1) and chemical structure. Volatile and semi-volatiles CAS Number MW Chemical structure Cis-Linalool oxide 1365-19-1 170.2 Furfural 98-01-1 96.1 α-Ionene 475-03-6 174.3 Trans-Linalool oxide 34995-77-2 170.2 Benzaldehyde 100-52-7 106.1 β-Linalool 78-70-6 154.3 Hotrienol 20053-88-7 152.2 Isophorone 78-59-1 138.2 4-Oxoisophorone 1125-21-9 152.2 1,1,5-Trimethyl-1,2- dihydronaphthalene (TDN) 30364-38-6 172.3 β-Damascenone 23696-85-7 190.3 Phenylfurane 13679-41-9 144.2 Benzyl alcohol 100-51-6 108.1 Phenylethyl Alcohol 60-12-8 122.2 Anisic aldehyde 123-11-5 136.1 1-(2,3-Dimethylphenyl)ethenone (DMPE) 2142-71-4 148.2 Megastigmatrienone A (MTMA) 5492-79-5 190.3
LÚA VÁZQUEZ FERREIRO 22 Table 3. (cont.) Volatile and semi-volatiles, CAS number, molecular weight (MW, g mol-1) and chemical structure. Volatile and semi-volatiles CAS Number MW Chemical structure γ-Eudesmol 15051-81-7 220.4 Megastigmatrienone B (MTMB) 5298-13-5 190.3 α -Eudesmol 473-16-5 220.4 β-Eudesmol 473-15-4 220.4 α-Gurjunene 489-40-7 204.4 Megastigmatrienone C (MTMC) 13215-88-8 190.3 5-Hydroxymethylfurfural (HMF) 67-47-0 126.1 Internal standards 1-Octanol 111-87-5 130.2 Celestolide 33704-61-9 244.4 2.3 PHENOLIC COMPOUNDS The antioxidant properties of honey are mainly attributed to its phenolic compound content, since they can eliminate free radicals and inhibit lipid oxidation. The different types of these compounds that may be present in honey, as well as their amount, depend mainly on the botanical origin, but also on other factors such as the climate or the processing. Phenolic compounds are deemed potentially useful markers for the characterization of honey, the determination of its botanical and/or geographical origin, the quality of honey and the nutraceutical value [25,27,33–35].
II. Introduction 23 A wide variety of phenolic compounds can be present in honey or other food matrices, and they can be classified as phenolic acids, flavonoids (flavonols, flavones, proanthocyanidins…), tannins, phenolic aldehydes, and others. Table 4 includes the phenolic compounds assessed in the present thesis, their CAS number, molecular weight (MW) and chemical structure. The data was obtained from ChemSpider (Predicted data is generated using the US Environmental Protection Agency‘s EPISuite™) and chemical structures were made by ChemDraw 20.1.1. Table 4. Phenolic compounds, CAS number, molecular weight (MW, g mol-1) and chemical structure. Phenolic compounds CAS number MW Chemical structure Phenolic acids Gallic acid 149-91-7 170.1 Phloroglucinic acid 71989-93-0 188.1 β-resorcylic acid 89-86-1 154.1 Protocatechuic acid 99-50-3 154.1 Caftaric acid 67879-58-7 312.2 p-hydroxybenzoic acid 99-96-7 138.1 Gentisic acid 490-79-9 117.1 3-hydroxyphenylacetic acid 621-37-4 152.2 Chlorogenic acid 327-97-9 354.3 Vanillic acid 121-34-6 168.2 γ-resorcylic acid 303-07-1 154.1
LÚA VÁZQUEZ FERREIRO 24 Table 4. (cont.) Phenolic compounds, CAS number, molecular weight (MW, g mol-1) and chemical structure. Phenolic compounds CAS number MW Chemical structure α-resorcylic acid 99-10-5 154.1 Veratric acid 93-07-2 182.2 Caffeic acid 331-39-5 180.2 p-coumaric acid 501-98-4 164.2 trans-ferulic acid 537-98-4 194.2 3,4,5-trimethoxycinnamic acid 90-50-6 238.2 Phenolic aldehydes Protocatechualdehyde 139-85-5 138.1 Gentisaldehyde 1194-98-5 138.1 3-hydroxybenzaldehyde 100-83-4 122.1 4-hydroxybenzaldehyde 123-08-0 122.1 Veratraldehyde 120-14-9 166.2 4-anisaldehyde 123-11-5 136.1 3,5-dimethoxybenzaldehyde 7311-34-4 166.2 Coumarins Umbelliferone 93-35-6 162.1
II. Introduction 25 Table 4. (cont.) Phenolic compounds, CAS number, molecular weight (MW, g mol-1) and chemical structure. Phenolic compounds CAS number MW Chemical structure Flavonoids Flavonols Myricetin 529-44-2 318.2 Quercetin 117-39-5 302.2 Kaempferol 520-18-3 286.2 Rutin 153-18-4 610.5 isoquercitrin 482-35-9 463.4 Miquelianin 22688-79-5 478.4 Flavones Apigenin 520-36-5 270.2 Chrysin 480-40-0 254.2 Flavanols Catechin 18829-70-4 290.3 Epicatechin 35323-91-2 290.3
LÚA VÁZQUEZ FERREIRO 26 Table 4. (cont.) Phenolic compounds, CAS number, molecular weight (MW, g mol-1) and chemical structure. Phenolic compounds CAS number MW Chemical structure Epigallocatechin gallate 989-51-5 458.4 Gallocatechin gallate 84650-60-2 458.4 Catechin gallate 130405-40-2 442.3 Proanthocyanidin Procyanidin B1 20315-25-7 578.5 Procyanidin B2 29106-49-8 578.5 Procyanidin A2 41743-41-3 576.5 2.4 LEGISLATION The Codex Alimentarius Commission standard for honey and the Directive 2001/110/EC established required composition criteria for sugar content, moisture content, water-insoluble content, electrical conductivity, free acid, diastase activity, and hydroxymethylfurfural
II. Introduction 27 content. Regarding the botanical origin of the product, if the honey comes wholly or "mainly" from the source indicated and possesses the organoleptic, physico-chemical and microscopic characteristics, the product may be labelled according to its floral or vegetable origin. In addition, the label shall also indicate the country or countries of origin in which the honey was harvested. It is of great importance to note that everything indicated in Codex Alimentarius is voluntary, while the European directive must be implemented in the member states, although they can issue national provisions, decisions and guidelines [20,21]. According to Regulation No 2081/92, honey may have a designation of origin if it has characteristics exclusively related to a specific region or to the specific local environment without modification. Thus, honeys can be classified under the labels of Protected Designation of Origin (PDO) and Protected Geographical Identification (PGI). Currently, in Spain there are five PDO registered honeys and one PGI (Galician honey) [36,37].
II. Introduction 29 3. PERSONAL AND PHARMACEUTICAL CARE PRODUCTS Personal and pharmaceutical care products (PPCPs) involve many chemical compounds used in many fields such as medicine, industry, livestock farming, aquaculture and people's daily life. Pharmaceuticals include all the drugs used for the treatment of diseases (antibiotics, antiinflammatory, antidepressants, β-blockers, etc.) and personal care products (PCPs) are typically utilized in cosmetics, detergents or other household products (fragrances, preservatives, siloxanes, etc). In addition to their presence in products, these substances are considered contaminants of emerging concern (CECs) [38]. In the course of this thesis, the presence of several PCPs in different cosmetic products was evaluated. Regarding pharmaceuticals, the occurrence of antibiotics and non-target compounds was carried out, as well as the evaluation of degradation under photolysis or advanced oxidation processes (AOPs). 3.1 COSMETICS 3.1.1 Introduction Cosmetics products are defined by the Regulation EC No 1223/2009 as “any substance or mixture intended to be placed in contact with the external parts of the human body (epidermis, hair system, nails, lips and external genital organs) or with the teeth and the mucous membranes of the oral cavity with a view exclusively or mainly to cleaning them, perfuming them, changing their appearance, protecting them, keeping them in good condition or correcting body odours” [39].
LÚA VÁZQUEZ FERREIRO 30 Cosmetic formulations can be classified according to their application e.g. make-up, hair product, cream, etc. or the area of the body on which they are applied. Furthermore, it is also important to differentiate between leave-on products, which remain on the contact surface for a period, and rinse-off products, which are removed after application. A wide variety of chemical compounds can be found in cosmetics, known as personal care products (PCPs). PCPs include different families of compounds of different nature, such as fragrance allergens, synthetic musks, preservatives, siloxanes, ultraviolet (UV) filters and plasticizers, among others. Additionally, PCPs enter the environment through domestic and industrial discharges. Another important source is effluents from waste treatment plants, because they only partially degrade these compounds. Several studied have demonstrated their presence in different environmental compartments, revealing their persistence in the environment or bioaccumulation, among other undesirable effects [40– 43]. 3.1.2 Studied PCPs Along this thesis, four different families of PCPs were determined: fragrances (allergens and synthetic musks), preservatives, UV filters and plasticizers. • Fragrances: they are often added to cosmetics in order to provide a pleasant scent and thus mask the unpleasant odours of the raw materials [44]. In this thesis two main groups can be differentiated: - Allergens: they provoke skin irritations or allergic reactions, such as skin sensitivity, rashes, dermatitis, coughing or asthma attacks. The Scientific Committee on Consumer Safety (SCCS) revealed that the frequency of contact allergy due to these
II. Introduction 37 Table 8. (cont.) UV filters, CAS number, molecular weight (MW, g mol-1) and chemical structure. UV filters CAS number MW Chemical structure Diethylaminohydroxy benzoyl hexyl benzoate (DHHB) 302776-68-7 397.5 Drometrizole Trisiloxane (DRT) 155633-54-8 501.8 • Plasticizers: they are used as solvents, fragrance fixers and to promote skin penetration. However, they can also be transferred from the plastic container to the cosmetic product. They can be differentiated according to the acid from which they are formed: phthalates, esters of phthalic acid, and adipates, esters of adipic acid [52,53]. Table 9 shows the target plasticizers (phthalates and adipates), their CAS number, molecular weight (MW) and chemical structure. The data was obtained from ChemSpider (Predicted data is generated using the US Environmental Protection Agency‘s EPISuite™) and chemical structures were made by ChemDraw 20.1.1. Table 9. Plasticizers, CAS number, molecular weight (MW, g mol-1) and chemical structure. Plasticizers CAS number MW Chemical structure Phthalates Dimethyl phthalate (DMP) 131-11-3 194.2 Diethyl phthalate (DEP) 84-66-2 222.2 Diisobutyl phthalate (DIBP) 84-69-5 278.3 Dibutyl phthalate (DBP) 84-74-2 278.3
LÚA VÁZQUEZ FERREIRO 38 Table 9. (cont.) Plasticizers, CAS number, molecular weight (MW, g mol-1) and chemical structure. Plasticizers CAS number MW Chemical structure Dimethoxyethyl phthalate (DMEP) 117-82-8 282.3 Diisophentyl phthalate (DIPP) 605-50-5 306.4 Dipentyl phthalate (DPP) 131-18-0 306.4 Benzylbutyl phthalate (BBP) 85-68-7 312.4 Diisoheptyl phthalate (DIHP) 41451-28-9 362.5 Di-2(ethylhexyl) phthalate (DEHP) 117-81-7 390.6 Dicyclohexyl phthalate (DCHP) 84-61-7 330.4 Diphenyl phthalate (DPhP) 84-62-8 318.3 Di-n-octyl phthalate (DNOP) 117-84-0 390.6 Adipates Dimethyl adipate (DMA) 627-93-0 174.2 Diethyl adipate (DEA) 141-28-6 202.2 Di-2-(ethylhexyl) adipate (DEHA) 103-23-1 370.6
II. Introduction 39 3.1.3 Legislation Cosmetics marketed in Europe must comply with Regulation 1223/2009, that provides different list of substances that are continuously revised and updated. Annex II involve more than one thousand five hundred chemical compounds prohibited in cosmetic products. Annex III includes the lists of substances allowed for use as cosmetic ingredients, although most of them are restricted in terms of maximum permitted concentration depending on the use of the final product or the product type. In addition, other positive lists are included in Annexes IV, V and VI for colorants, preservatives and UV filters, respectively, in order to be allowed as ingredients with the corresponding functions in cosmetics. The presence of perfuming and aromatic substances as fragrances (allergens and synthetic musks) shall be indicated by the terms "parfum" or "fragrance" according to Regulation 1223/2009. In addition, the mention of the 26 fragrance allergens on the product labelling is mandatory if their concentration exceeds 0.01% by weight (100 μg g-1) for rinse-off products and 0.001% by weight (10 μg g-1) for leave-on products. However, some of the fragrances, both allergenic and synthetic musks, plasticizers, preservatives (Annex V) and UV filters (Annex VI) have restrictions on the maximum concentration allowed according to the type of product and/or the part of the body on which it is applied. In addition, it should be noted that some of them are listed in Annex II and therefore banned in cosmetic products. Table 10 includes the current specific restrictions for the target PCPs. For those compounds that are not specified in the table there are no restrictions at this stage (May 2022), except all fragrance allergens included in this thesis (excluding pinene and mehytleugenol), that must comply with the product labelling mentioned above [39].
LÚA VÁZQUEZ FERREIRO 40 Table 10. Specific restrictions of the studied PCPs in cosmetic products according to Regulation 1223/2009 [39]. PCPs Restrictions Fragrance allergens Methyleugenol Fine fragrance (0.01%) Eau de toilette (0.004 %) Fragrance cream (0.002%) Other leave-on products and oral products (0.0002%) Rinse-off products (0.001%) Isoeugenol 0.02% (except oral products) Lilial® Prohibited Lyral® Prohibited Synthetic musks Musk xylene All cosmetics except oral products: Fine fragrance (1,0 %) Eau de toilette (0,4 %) Other products (0,03%) Musk ambrette Prohibited Musk moskene Prohibited Musk tibetene Prohibited Phantolide Leave-on products (2%) Tonalide All cosmetics except oral products: Leave-on products (0.1%) except hydroalcoholic products (1%), fine fragrance (2.5%) and fragrance cream (0.5%). Rinse-off products (0.2%) Preservatives Bronidox Rinse-off products (0.1 %) PhEtOH 1% TCS Toothpastes, hand soaps, body soaps/shower gels, deodorants (non-spray), face powders and blemish concealers, nail products for cleaning the fingernails and toenails before the application of artificial nail systems (0.3%) Mouthwashes (0.2%) MeP, EtP Single ester (0.4% as acid) Mixtures of esters (0.8% as acid) iPrP Prohibited PrP, BuP The sum of the individual concentrations (0.14% as acid) Mixtures of substances (0.8% as acid)* Prohibited in leave-on products designed for application on the nappy area of children under 3 years of age IPBC Rinse-off products (0.02%), prohibited in products for children under 3 years of age except bath products. Leave-on products (0.01%), prohibited in body lotion and body cream, and products for children under 3 years of age Deodorants/anti-persistent (0.0075%), prohibited in products for children under 3 years of age
II. Introduction 41 Table 10. (cont.) Specific restrictions of the studied PCPs in cosmetic products according to Regulation 1223/2009 [39]. PCPs Restrictions iBuP Prohibited BzP Prohibited UV filters EHS 5% HMS 10% BP 6% and it must be indicated in the label ‘Contains benzophenone-3’ if the concentration exceeds 0.5 % (not for product protection purposes). IAMC 10% 2EHMC 10% 4MBC 4 % OCR 10 % (as acid) DHHB 10 % DRT 15% Plasticizers DIBP Prohibited DBP Prohibited DMEP Prohibited DIPP Prohibited DPP Prohibited BBP Prohibited DEHP Prohibited DCHP Prohibited *Mixture of substances mentioned in entry 12 and 12a of Regulation No 1223/2009, where the sum of the individual concentrations of butyland propylparaben and their salts does not exceed 0.14 % There are products, so-called borderline products, that sometimes it is unclear whether they should be regulated as cosmetics or other legislation. This is the case of hydroalcoholic gels, included in the present thesis [54]. The World Health Organization (WHO) published a protocol to homogenise formulation and fabrication of this product, with the aim of assure their antimicrobial properties [55]. However, they can be considered biocides or cosmetic product. Biocide is defined as “any substance or mixture, in the form in which it is supplied to the user, consisting of, containing or generating one or more active substances, with the intention of destroying, deterring, rendering harmless, preventing the action of, or otherwise exerting a controlling
LÚA VÁZQUEZ FERREIRO 42 effect on, any harmful organism by any means other than mere physical or mechanical action” by Regulation No 528/2012 [56]. Nevertheless, if the main purpose of hydroalcoholic gels is cleaning or cleansing the skin, they are subject to the Cosmetic Products Regulation. 3.2 ANTIBIOTICS 3.2.1 Introduction Antibiotics are a class of pharmaceuticals which act on the metabolism of bacteria, fungi, and protozoa to inhibit microbial growth. They are used for the treatment of infectious diseases, although recently they have also been used for other therapies such as cancer treatment or organ transplantation. These chemical compounds can be classified according to their origin (natural, synthetic or semi-synthetic), chemical structure or mechanism of action. Despite being a very useful tool for curing diseases, both for human and veterinary, the misuse of these compounds has led to a rapid increase in antimicrobial resistance. They are mainly excreted as the active and metabolite forms via urine or faeces [57–59]. Table 11 depicts the families and antibiotics included in this report, their CAS number, molecular weight (MW) and chemical structure. The data was obtained from ChemSpider (Predicted data is generated using the US Environmental Protection Agency‘s EPISuite™) and chemical structures were made by ChemDraw 20.1.1.
II. Introduction 43 Table 11. Families and antibiotics, CAS number, molecular weight (MW, g mol-1) and chemical structure. Family Antibiotic CAS number MW Chemical structure Natural antibiotics Macrolides Azithromycin (Azi) 83905-01-5 749.0 Clarithromycin (Clar) 81103-11-9 748.0 Erythromycin (Ery) 114-07-8 734.0 Roxithromycin (Rox) 80214-83-1 837.0 Cephalosporins Cephalexin (Ceph) 15686-71-2 347.4 Synthetic antibiotics Fluoroquinolones Ciprofloxacin (Cipro) 85721-33-1 331.3 Enrofloxacin (Enro) 93106-60-6 359.4 Norfloxacin (Nor) 70458-96-7 319.3 Ofloxacin (Oflo) 82419-36-1 361.4
LÚA VÁZQUEZ FERREIRO 44 Table 11. (cont.) Families and antibiotics, CAS number, molecular weight (MW, g mol-1) and chemical structure. Family Antibiotic CAS number MW Chemical structure Sulfonamides Sulfadiazine (SDZ) 68-35-9 250.3 Sulfadimidine (SDMD) 57-68-1 278.3 Sulfamerazine (SMZ) 127-79-7 264.3 Sulfamethoxazole (SMX) 723-46-6 253.3 Diaminopyrimidines Trimethoprim (TMP) 738-70-5 290.3 Isotopically labelled compounds Clarithromycin-D3 (Clar-D3) 959119-17-6 751.0 Norfloxacin-D5 (Nor-D5) 1015856-57-1 324.4 Sulfamethoxazole- D4 (SMX-D4) 1020719-86-1 257.3 3.2.2 Occurrence in the environment PPCPs are CECs as they can easily enter the environment and pose risks to ecosystems and human health. Antibiotics are one of the most interesting groups, since their residues as active substance or metabolites, lead to the emergence of antibiotic resistant bacteria and antibiotic resistance genes [60]. The main source of antibiotics into the environment is through wastewater treatment plants (WWTPs), as most of them are only
II. Introduction 45 partially degraded. The removal efficiency depends on the class of antibiotics, their physicochemical properties and the operating conditions of the WWTPs. In addition, antibiotics can reach the environmental compartments through other routes, such as liquid manure, aquaculture, the reuse of activated sludge as biofertilizers, etc [59]. The presence of antibiotics has been reported in wastewater, both influent and effluent, from different WWTPs such as urban, hospital or industrial. In addition, numerous studies have reported the presence of antibiotics in natural waters, including lakes, rivers, sea and groundwater, as well as in water for human consumption such as tap water or drinking water. On the other hand, they have also been found in soils, so that through leaching they can also easily reach the aquatic environment [61–65]. 3.2.3 Photodegradation and advanced oxidation processes Photodegradation is defined by the International Union of Pure and Applied Chemistry (IUPAC) as “the photochemical transformation of a molecule into lower molecular weight fragments, usually in an oxidation process. This term is widely used in the destruction (oxidation) of pollutants by UV based processes”. As conventional WWTPs are not able to fully remove antibiotics, other processes are necessary to enable their complete elimination, being photodegradation an interesting alternative [66]. In the electromagnetic sector, UV radiation includes X-rays and visible light. In terms of wavelength range, UV radiation can be divided into three distinct regions: UVA (320-400 nm), which can be divided into UV-I or short UVA (340-400 nm) and UVA-II or long UVA (320- 340 nm), UVB (290-320 nm) and UVC radiation (100-290 nm). Photodegradation in water can be performed by direct or indirect photolysis. The first one is conducted when the substance absorbs light energy, causing it to decompose and, the second one occurs when light energy is absorbed by the photosensitisers (natural components of
LÚA VÁZQUEZ FERREIRO 46 water) that prompt the photocatalytic reaction [67]. For UV light, low and medium pressure mercury vapor lamps are the most widely used. As regards the removal of antibiotics in this thesis, low-pressure mercury lamps emitting monochromatic UV light at 254 nm (UVC) were employed [68]. Advanced oxidation processes (AOPs) have been proposed in 1987 as a promising alternative for potable water purification [69]. However, nowadays it is well known that AOPs are very effective as tertiary treatment in WWTPs for the elimination of a wide variety of CECs. AOPs are characterized by the generation of highly reactive oxidizing species (ROS), by using different oxidants (H2O2, S2O82-,O3 etc) which produce radicals, as hydroxyl radical (HO•) and sulfate radical (SO4-•) among others. These formed radicals, under different chemical reactions, allow the degradation and mineralization of the organic compounds. In addition, catalysts can be used to accelerate reactions. Heterogeneous photocatalyst is based on direct or indirect absorption of radiant energy (UV or visible) by a solid photocatalyst (TiO2, Ag2MoO4, etc) [70,71]. Several systems based on AOPs are proposed for the removal of different CECs. Recently, Vilar et al.in 2020 proposed the tube-in-tube membrane reactor as a promising alternative for water decontamination [72]. This reactor is a low footprint technology whose design enables the integration of different ROS generation mechanisms within a single unit operated in continuous-flow mode. The degradation of antibiotics in aqueous media has been evaluated in several studies. However, during these processes, a transformation of the substances can occur, giving rise to by-products which may be more toxic and persistent than the parent substance, and therefore more harmful to the human health and environment [73,74].
II. Introduction 53 only in the laboratory, but also in the field. The SPME consists of using a fused silica fibre, chemically inert and very stable even at high temperatures, covered with an ab/adsorbent polymeric phase. To carry out extraction, the coated fused silica is placed in a holder resembling a syringe. The main advantages of this extraction technique are its simplicity, since the device is easy to handle and to apply in the field, its ability to perform one-step sample preparation, and the high sensitivity as the extracted analytes are concentrated on the fibre and directly introduced in the chromatographic system (GC). In addition, the sample amount is usually low, and the use of organic solvents is negligible or even absent. Residue generation is also minimal, so that SPME can be considered an environmentally friendly sample preparation approach. Besides, it is easy to automate, which offers high time efficiency and increased simplicity [91,92]. 4.3.2. Experimental procedure The SPME procedure consists on [93]: 1. Extraction: the fibre is exposed to the sample placed in a sealed vial. In this way, there is a migration of the analytes from the sample to the fibre. 2. Desorption: the fibre with the retained and concentrated analytes can be directly introduced into the injector of a gas chromatograph to be thermally desorbed, or desorbed in a solvent for liquid chromatographic analysis. The extraction can be carried out by two different extraction modes (see Figure 4.2): • Headspace mode: the fibre is exposed to the headspace above the sample, whereby analytes first migrate from the sample to the headspace to be subsequently ab/adsorbed in/on the fibre. It is widely used for the extraction of volatile and semi-volatile substances.
LÚA VÁZQUEZ FERREIRO 54 • Direct immersion mode: the fibre is directly introduced into the sample so that the compounds can migrate from the matrix to the fibre. This extraction mode is used for simple matrices and usually for slightly volatile compounds. Figure 2. SPME extraction modes. 4.3.3. Parameters affecting SPME Many parameters can affect SPME [93,94]: • Fibre coating: there are many types of polymeric phases with different polarities and thickness. The fibre affinity for an analyte can be initially determined according to their polarity. • Extraction time: the SPME is an equilibrium technique, implying that the highest analyte extraction is achieved in the time it takes to reach equilibrium. However, a shorter extraction time can be chosen if there is strict control of the process to ensure that good reproducibility is obtained.
II. Introduction 55 • Extraction temperature: the diffusion of the analytes to the fibre is usually favoured at higher temperatures. In addition, in headspace mode, the temperature increase eases the transfer of the analytes into the headspace. However, the fibre/sample distribution constant decreases with the temperature increase, as the absorption step is an exothermic process. • Sample pH: the pH of the solution can affect the dissociation equilibrium of analytes with acidic or basic groups. Thus, to obtain high extraction efficiency, the pH must be two units below the pKa for acidic compounds and two units above for basic compounds. • Salting-out effect: the ionic strength is increased when salts like NaCl or KCl are added in the aqueous solution, favouring a decrease of the analyte solubility in water, and promoting their migration to other phases of the system, such as the headspace and the fibre. • Agitation: stirring the sample can facilitate the diffusion of analytes to the fibre, accelerating the extraction time. • Addition of solvent: the addition of organic solvents or water in the case of solid samples can favour the diffusion of analytes from the matrix to the fibre, whereas solvents in aqueous solutions usually decrease the extraction efficiency. • Sample and headspace volume: if the system consists of three phases (sample, fibre and headspace), the amount of analytes extracted follows the equation: n = KfsVfVs KfsVf+ KhsVh+ Vs C0 Where, n are the moles of analytes extracted; Kfs is the distribution constant between the fibre and sample and Khs between the headspace and sample; Vf, Vs, and Vh are the volumes of fibre, sample and headspace, respectively; C0 is the initial analyte concentration in the sample. Therefore, if the volume of the sample increases, the amount of analyte extracted will also increase until a certain volume from which
LÚA VÁZQUEZ FERREIRO 56 the amount of analyte extracted will no longer increase. In this case, the volume of sample does not influence the amount of analyte extracted following the next equation: n = KfsVfC0 Regarding the headspace volume in eq. 1, when it increases, the amount of analyte extracted decreases. 4.3.4. Applications SPME has been proposed for multiple applications, being one of the preferred extraction techniques to determine volatile and semivolatile organic compounds in food samples, as is the case of honey [95,96]. In addition, it has been applied for the determination of a wide variety of organic analytes, including personal care products, in environmental, biological, and cosmetic samples [97–100]. A miniaturized method based on SPME was developed in Section IV, Chapter 2.1, for the analysis of honey samples. Furthermore, in Chapter 3.2, SPME was applied for the determination of personal care products in hydroalcoholic gels. 4.4. FABRIC PHASE SORPTIVE EXTRACTION (FPSE) 4.4.1. Introduction Fabric Phase Sorptive Extraction (FPSE) has been introduced as a novel sample preparation approach by Kabir and Furton in 2014 [101]. It can be considered as combination of the extraction mode of SPME (equilibrium extraction) and SPE (exhaustive extraction) into a single technology platform. FPSE allows direct extraction of the analytes present in the sample, since no other pre- or post-extraction procedures (filtration, centrifugation, solvent evaporation, etc.) are necessary, thus avoiding errors and additional costs.
II. Introduction 57 It consists of a flexible fabric (cellulose, polyester, or fiberglass) as the substrate, which is chemically coated with an ultra-thin coating with sol-gel organic-inorganic hybrid sorbent as the extraction medium [101,102]. 4.4.2. Experimental procedure It exists a protocol involving 3 steps to carry out the FPSE, described in Figure 4.3 [103]: 1. Cleaning the membrane: the coated fabric is introduced in 2 mL of acetonitrile:methanol (ACN:MeOH, 50:50, v/v) solution during 5 minutes and then in 2 mL of ultrapure water to remove the residual organic solvents. This step can be repeated twice. 2. Extraction: the clean FPSE membrane is immersed in the sample contained in a vial in which the sorption of the target analytes by the sorbent will take place. After the extraction, the FPSE device is removed from the vial and left to dry. 3. Elution: the dried FPSE device is inserted in a vial to accomplish solvent desorption. It can be stirred, vortexed or centrifuged to favour the process. Figure 3. FPSE schematic procedure.
LÚA VÁZQUEZ FERREIRO 58 4.4.3. Parameters affecting FPSE The efficiency of the FPSE procedure can be increased/decreased depending on some parameters [104]: • Fabric substrates: the different nature of the substrates is very important and determines the selectivity and the polarity of the FPSE media. The substrates can be hydrophilic (cotton cellulose), hydrophobic (polyester), or both (cotton-polyester). • Sol-gel sorbent: the organic/inorganic polymer plays the most significant role in the sorbent selectivity. The polymer polarity (nonpolar, medium polar and polar) is determined according to the analytes. • Extraction time: extraction efficiency is influenced by the time required to reach equilibrium. • Agitation: stirring or sonication can promote the diffusion of analytes from the sample to the extraction phase, reducing the time needed to reach extraction equilibrium. • Effect of salt content: the addition of salt to the sample matrix is an important parameter to evaluate, as it generally decreases the solubility of organic analytes providing higher extraction efficiency. However, it can increase the viscosity of the solution, reducing the diffusion rate of the analytes. • Elution solvent and volume: the solvent should be selected according to the polarity of the analytes. In terms of volume, lower volumes can provide higher enrichment factors, although it is important to ensure that the device is completely immersed. • Elution time: the desorption time is expected to be fast, because the solvent can easily penetrate the ultra-thin coating of the sol-gel sorbent as well as the pores of the textile substrate. Nevertheless, it highly depends on the affinity of the analytes for the solvent.
II. Introduction 59 • Sample volume: the amount of extracted analyte increases with the sample volume up to a certain volume which, according to equation 2 (Section 4.3.3), the amount of extracted analyte does not increase. 4.4.4. Applications The variety of the available sorbents allows the application of the FPSE for different type of samples. It has been broadly used for the extraction of organic compounds in environmental, food and biological samples [103,105–108]. In Section IV, Chapter 1.2, a methodology based on FPSE has been developed for the determination of fungicides in environmental waters. 4.5. MATRIX SOLID-PHASE DISPERSION (MSPD) 4.5.1. Introduction Matrix solid-phase dispersion (MSPD) was introduced by Barker and co-workers in 1989 [109]. It combines aspects of several analytical techniques, allowing the disruption and dispersion of the sample on a solid support, generating a unique chromatographic material. This sample procedure can be applied for the preparation, extraction and fractioning of solid, semi-solid or highly viscous samples. MSPD allows extraction and cleaning to be performed at the same time, which reduces the chances of sample contamination during the procedure. In addition, it does not require the use of expensive and specific instrumentation, and the soft extraction conditions (ambient temperature and atmospheric pressure) allow using low volumes of organic solvents [110]. Besides, in order to further reduce the amounts of sample, dispersing agent and solvent, the MSPD miniaturization has been proposed, and called micro-MSPD (µMSPD) [111].
LÚA VÁZQUEZ FERREIRO 60 4.5.2. Experimental procedure The classic procedure implies the steps described below (see µMSPD procedure in Figure 4.4) [112]: The solid, semi-solid or viscous sample is added in a mortar or a vial where it is mixed with a dispersing agent in order to achieve a complete disruption and dispersion of the sample. In addition, sometimes, a desiccant such as anhydrous sodium sulphate (Na2SO4) is also needed to obtain a finely divided material, dry enough for subsequent extraction. 1. Once the sample disruption and dispersion stage are completed, the resulting mixture is packed into an empty column, which is usually an empty syringe body, with a frit at the bottom. However, with the aim of miniaturize the procedure using the lowest amounts of sample and materials, a Pasteur pipette (approximately 150 mm) can be used with glass wool in the bottom in the case of µMSPD. In addition, in order to obtain a further degree of fractionation and an in-situ clean-up step, a small amount of Florisil or other sorbent agent can be added between the glass wool and the sample. Once the sample is packed, a second frit or glass wool is placed on top of the mixture and then compressed to avoid air bubbles. 2. The elution can be carried out according to two ways: a) The analytes of interest are retained on the column and interfering compounds are eluted during the washing step. Then, the target compounds are eluted with another solvent. b) The matrix interferences are retained on the column and the target analytes are eluted with a solvent. 3. The extract can be directly analysed or, if necessary, an additional cleaning step can be carried out.
II. Introduction 61 Figure 4. µMSPD schematic procedure. 4.5.3. Parameters affecting MSPD Several factors can affect the MSPD extraction efficiency [110]: • Dispersing agent: classical MSPD applications employ silicabased sorbents as dispersing agent. These materials have the additional advantage of containing free silanol groups, acting at the same time as dispersing and desiccant agents since they are able to form hydrogen bonds with water molecules. Usually, reversed-phase bonded silicas are employed (C8 and C18) but other modified reversed materials are also used for the extraction of more polar compounds, such as silica bonded to polar groups (e.g. amines) or non-bonded inorganic oxides (silica itself, alumina, Florisil). • Matrix modification: sometimes, it is necessary to modify some matrix parameters acting on the pH adjustment, or with the addition of salts, chelating agents or de-chelating agents, antioxidants, etc... This can be done during the sample blending and/or further on modifying the eluting solvent composition, with the aim of altering the ionization state of the sample components to assure that certain interactions occur between the solid support bonded-phase and/or the eluting solvent.
LÚA VÁZQUEZ FERREIRO 62 •Solvent: the nature of the elution solvent affects the selectivity towards the analytes. The aim is desorbing the compounds of interest, while the matrix components are retained on the column. 4.5.4. Applications MSPD has been used for a wide variety of compounds including PCPs and pesticides and many matrices (food, environmental, cosmetics) [113–116]. In addition, the µMSPD was also applied for the analysis of cosmetics and food samples [117–121]. In Section IV, Chapter 3.1 a method based on µMSPD has been developed to determine PCPs in cosmetic formulations. In addition, the MSPD viability was tested for the extraction of fungicides in leaves in Chapter 1.3. 4.6. ULTRASOUND ASSISTED EXTRACTION (UAE) 4.6.1. Introduction Ultrasound Assisted Extraction (UAE) is a simple, fast and lowcost technique based on ultrasounds, sound waves with frequencies higher than the upper audible limit of human hearing. It consists of applying ultrasound energy to extract liquid or solid samples. This energy provokes the formation and implosion of bubbles according to a phenomenon called cavitation. The continuous agitation of the organic solvent facilitates the mass transfer processes between the two phases as the solvent penetrates further into the different matrices [122]. 4.6.2. Experimental procedure UAE can be performed employing an ultrasonic bath or an ultrasonic probe. In the first case, which is the most available and cheapest source of ultrasound irradiation, the sample (liquid or solid) is mixed with a solvent and immersed into a ultrasonic bath applying a
II. Introduction 69 radiofrequency potential is applied. These analysers act as mass filters, because they only allow ions with a certain m/z ratio to pass through to the detector. Ions that do not have the m/z ratios recognised by the quadrupole reach the bars (cylinders) and become neutral molecules. This kind of mass analyser instruments are the most compact, cheapest and most powerful [138,139]. There are different ion monitoring modes: • Full scan (FS): all masses are registered without filtration. • Selected ion monitoring (SIM): only ions with a specific mas- to-charge (m/z) are filtered. Moreover, GC can be coupled to a tandem mass spectrometer (MS/MS) instead of a simple quadrupole (MS). The most common tandem mass spectrometer is the triple quadrupole mass spectrometer (QqQ) which consists of the combination of 2 quadrupoles and a collision cell to achieve the filtration of ions with a specific m/z ratio and their subsequent fragmentation. This instrument can work in different ion monitoring modes: • FS as single quadrupoles. • Selective reaction monitoring (SRM): the first (Q1) and third (Q3) quadrupoles filter specific m/z of the ions, thus working in SIM mode. First, Q1 filter some ions and, after fragmentation by the action of the collision gas (an inert gas such as argon) in the second quadrupole (q2) or collision cell, selected product ions are analysed in Q3. Employing this mode, interferences are minimized or even avoided, providing a sensitive and selective tool that allows chromatograms with very low noise. Figure 5.1 describes the configuration of a triple quadrupole mass spectrometer working in SRM mode.
LÚA VÁZQUEZ FERREIRO 70 Figure 5. Scheme of a triple quadrupole mass spectrometer working in SRM mode. GC coupled to MS in FS mode was applied for the analysis of volatile and semi-volatile compounds in honey (Section IV, Chapter 2.1). In addition, GC-MS/MS working in SRM mode was used for the determination of fungicides (Section IV, Chapter 1) and personal care products in cosmetic formulations (Section IV, Chapter 3). 5.3. LIQUID CHROMATOGRAPHY (LC) 5.3.1. Introduction Liquid chromatography (LC) is based on the distribution of the analytes between a liquid mobile phase and a solid stationary phase (chromatographic column). The most commonly used liquid chromatography is partition chromatography (which was used in this doctoral thesis), but there are other types such as adsorption, ion exchange or molecular exclusion chromatography. In this case, the stationary phase consists of a packed column filled with silica porous particles coated with an organic film (octadecyl in this case) linked by chemical bonds. LC allows the separation of non-volatile, polar and/or thermally unstable compounds [138]. Ultra-high performance liquid chromatography (UHPLC) enables using of small particle-packed columns with small diameter, which withstand higher system pressures during chromatographic analysis. The advantages provided by UHPLC are and analysis time, a high peak resolution and excellent peak shape, as well as an increase in sensitivity [140].
II. Introduction 71 Both LC and UHPLC can be coupled to mass spectrometry. 5.3.2. Mass spectrometry In this thesis, LC was used coupled to tandem mass spectrometry, using low-resolution triple quadrupole mass spectrometry, and highresolution mass spectrometry (HRMS), employing a single or triple quadrupole time-of-flight analysers. As liquid samples cannot be introduced directly into the mass spectrometer, the ionization source must vaporize them transforming the molecules into gas-phase ions. Then, after leaving the ion source, the ions are filtered according to their m/z ratios in the analyser and passed to the detector [139]. There are different ion sources for generating gas-phase ions from the liquid phase and connecting LC with MS. The most commonly sources of atmospheric pressure ionization are atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI), both soft ionization sources. The latter, ESI, has been used in the present thesis, as well as HESI (heated electrospray ionization). In this source, first, a small flow of the sample solution is conducted through a capillary in which it is nebulized, forming charged droplets when a high voltage is applied. The droplets then shrink by evaporation of the solvent and disintegration of the droplets, and finally there is the emission or production of ions from the highly charged droplets (coulombic explosion) [141]. In the present work, LC-MS/MS has been employed to analyze phenolic compounds in honey samples in SRM acquisition mode (Section IV, Chapter 2.2). In addition, UHPLC-HRMS has been employed for the analysis of antibiotics and non-target compounds in water (Section IV, Chapter 4). 5.3.3. High-resolution mass spectrometry (HRMS) High-resolution mass spectrometry (HRMS) provides MS/MS spectra and accurate monoisotopic mass measurements, which are
LÚA VÁZQUEZ FERREIRO 72 highly applicable not only for the confirmation of targeted compounds but also for the identification of unknown compounds. In addition to the retention time and ion fragment ratio, HRMS also offers the exact mass, isotope profile and the possibility of spectral comparison against spectra libraries [142]. During this thesis, two approaches of HRMS based on single (QToF) and triple (QqTof) quadrupole time-of flight were used. • The QToF operated in broadband collision-induced dissociation (bbCID), which is a Data Independent Acquisition (DIA) mode. It works in rapid and continuous cycles at low and high collision energy, simultaneously providing MS and MS/MS spectra and providing information on precursor ions and fragmentation patterns in a single analysis [143]. • The QqTof (TripleToF®) worked by a DIA approach based on SWATHTM (Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra). MS/MS spectra are acquired for all precursor ions over a specified wide mass range, dividing the entire mass range into smaller m/z windows. This allows the analysis of each window to be repeated several times during the elution of a chromatographic peak; thus, for each detectable analyte in the sample passing through Q1, a complete MS and MS/MS spectrum is acquired. This tool also allows retroactive data mining without re-analysis, which is very useful for the identification of non-targeted unknown compounds [144]. Figure 5.2 includes the scheme of a QqToF spectrometer.
II. Introduction 73 Figure 6. QqToF spectrometer scheme. HRMS was utilized for the analysis of target antibiotics (QToF) and non-target approaches (TripleToF®) (Section IV, Chapter 4). 5.4. UV-VIS SPECTROSCOPY Spectroscopy is a science that studies the interaction of radiation with matter. UV-Vis molecular absorption spectroscopy is based on the measurement of transmittance (T) or absorbance (A). To perform this, a beam of light at a certain wavelength (λ, nm) is passed through a solution contained in a transparent bucket or cell which, depending on the spectral range of the measurement, is made of plastic, glass or quartz, and the amount of light absorbed by the solution is recorded/measured [139]. 5.4.1 Total Phenolic Content and Antioxidant Activity The chemical composition of honey can be studied in terms of total phenolic content (TPC) without having to selected phenolic compounds as targets. It can be determined according to the Folin–Ciocalteu (FC)
LÚA VÁZQUEZ FERREIRO 74 colorimetric method described by Singleton and Rosssi [145], carrying out the measurement at 760 nm in a UV-Vis spectrophotometer. Antioxidant activity (AA) is strongly correlated with the total phenolic content. It varies greatly depending on the botanical origin and its colour, while on a minor average it is considered to be affected by processing, handling and storage [146]. There is no official method to determine AA in honey, but several approaches can be applied as ORAC (oxygen radical absorbance capacity), FRAP assay (ferric reducing antioxidant power), DPPH scavenging (1,1-diphenyl-2- picrylhydrazyl), and TEAC (Trolox equivalent antioxidant activity) [147]. In this thesis, the AA was assessed employing the DPPH protocol by a modified method of Brand–Williams et al. [148] (absorbance measured at 515 nm). Therefore, an UV-Vis spectrophotometer in the visible spectrum was employed to determine TPC and AA indexes in honey samples (Section IV, Chapter 2.2).
II. Introduction 77 REFERENCES [1] European Commission, Pesticides, (2022). https://ec.europa.eu/food/plants/pesticides_en (accessed May 7, 2022). [2] P.K. Gupta, Herbicides and Fungicides, in: Reprod. Dev. Toxicol., 2nd ed., Academic Press, 2017: pp. 657–679. https://doi.org/10.1016/B978-0-12-804239-7.00037-8. [3] P.K. Gupta, Toxicity of Fungicides, in: Vet. Toxicol., 3rd ed., Academic Press, 2018: pp. 569–580. https://doi.org/10.1016/B978-0-12-811410-0.00045-3. [4] World Health Organization, The Who recommended classification of pesticides by hazard and guidelines to classification, 2019. https://www.who.int/publications/i/item/9789240005662 (accessed May 7, 2022). [5] M. Carmona, F. Sautua, O. Pérez-Hérnandez, E.M. Reis, Role of Fungicide Applications on the Integrated Management of Wheat Stripe Rust, Front. Plant Sci. 11 (2020) 733. https://doi.org/10.3389/FPLS.2020.00733/BIBTEX. [6] FRAC Code List ©* 2020, Fungal control agents sorted by cross resistance pattern and mode of action, 2020. https://cpb-us- w2.wpmucdn.com/u.osu.edu/dist/b/28945/files/2020/02/fraccode-list-2020-final.pdf (accessed May 7, 2022). [7] M. Komárek, E. Čadková, V. Chrastný, F. Bordas, J.C. Bollinger, Contamination of vineyard soils with fungicides: A review of environmental and toxicological aspects, Environ. Int. 36 (2010) 138–151. https://doi.org/10.1016/J.ENVINT.2009.10.005. [8] C. Patinha, N. Durães, A.C. Dias, P. Pato, R. Fonseca, A. Janeiro, F. Barriga, A.P. Reis, A. Duarte, E. Ferreira da Silva, A.J. Sousa,
LÚA VÁZQUEZ FERREIRO 78 A. Cachada, Long-term application of the organic and inorganic pesticides in vineyards: Environmental record of past use, Appl. Geochemistry. 88 (2018) 226–238. https://doi.org/10.1016/J.APGEOCHEM.2017.05.014. [9] E. Herrero-Hernández, M.S. Andrades, A. Álvarez-Martín, E. Pose-Juan, M.S. Rodríguez-Cruz, M.J. Sánchez-Martín, Occurrence of pesticides and some of their degradation products in waters in a Spanish wine region, J. Hydrol. 486 (2013) 234– 245. https://doi.org/10.1016/J.JHYDROL.2013.01.025. [10] C. Druart, M. Millet, R. Scheifler, O. Delhomme, C. Raeppel, A. De Vaufleury, Snails as indicators of pesticide drift, deposit, transfer and effects in the vineyard, Sci. Total Environ. 409 (2011) 4280–4288. https://doi.org/10.1016/J.SCITOTENV.2011.07.006. [11] M. Celeiro, R. Facorro, T. Dagnac, M. Llompart, Simultaneous determination of trace levels of multiclass fungicides in natural waters by solid - phase microextraction - gas chromatographytandem mass spectrometry, Anal. Chim. Acta. 1020 (2018) 51– 61. https://doi.org/10.1016/J.ACA.2018.03.014. [12] Y. Zhong, Z.F. Chen, S.S. Liu, X. Dai, X. Zhu, G. Zheng, S. Liu, G. Liu, Z. Cai, Analysis of azole fungicides in fish muscle tissues: Multi-factor optimization and application to environmental samples, J. Hazard. Mater. 324 (2017) 535–543. https://doi.org/10.1016/J.JHAZMAT.2016.11.024. [13] A. Pérez-Parada, G. Goyenola, F. Teixeira de Mello, H. Heinzen, Recent advances and open questions around pesticide dynamics and effects on freshwater fishes, Curr. Opin. Environ. Sci. Heal. 4 (2018) 38–44. https://doi.org/10.1016/J.COESH.2018.08.004. [14] EFSA, Pesticides, (2022). https://www.efsa.europa.eu/en/topics/topic/pesticides#peerreview (accessed May 11, 2022). [15] Directive 2009/128/EC of the European Parliament and of the
II. Introduction 85 2010.5 (accessed May 8, 2022). [56] Regulation (EU) No 528/2012 of the European Parliament and of the Council of 22 May 2012 concerning the making available on the market and use of biocidal products, Eur. Off. J. L167 (2012) 1–123. [57] S.I. Maffioli, A Chemist’s Survey of Different Antibiotic Classes, in: Antibiotics, 1st ed., Wiley-VCH Verlag GmbH & Co. KGaA, 2013: pp. 1–22. https://doi.org/10.1002/9783527659685.ch1. [58] M. Hutchings, A. Truman, B. Wilkinson, Antibiotics: past, present and future, Curr. Opin. Microbiol. 51 (2019) 72–80. https://doi.org/10.1016/J.MIB.2019.10.008. [59] R.K. Langbehn, C. Michels, H.M. Soares, Antibiotics in wastewater: From its occurrence to the biological removal by environmentally conscious technologies, Environ. Pollut. 275 (2021) 116603. https://doi.org/10.1016/J.ENVPOL.2021.116603. [60] J. Wang, L. Chu, L. Wojnárovits, E. Takács, Occurrence and fate of antibiotics, antibiotic resistant genes (ARGs) and antibiotic resistant bacteria (ARB) in municipal wastewater treatment plant: An overview, Sci. Total Environ. 744 (2020) 140997. https://doi.org/10.1016/J.SCITOTENV.2020.140997. [61] M. Bilal, S. Mehmood, T. Rasheed, H.M.N. Iqbal, Antibiotics traces in the aquatic environment: persistence and adverse environmental impact, Curr. Opin. Environ. Sci. Heal. 13 (2020) 68–74. https://doi.org/10.1016/J.COESH.2019.11.005. [62] U. Szymańska, M. Wiergowski, I. Sołtyszewski, J. Kuzemko, G. Wiergowska, M.K. Woźniak, Presence of antibiotics in the aquatic environment in Europe and their analytical monitoring: Recent trends and perspectives, Microchem. J. 147 (2019) 729– 740. https://doi.org/10.1016/J.MICROC.2019.04.003. [63] B. Albero, J.L. Tadeo, M. Escario, E. Miguel, R.A. Pérez,
LÚA VÁZQUEZ FERREIRO 86 Persistence and availability of veterinary antibiotics in soil and soil-manure systems, Sci. Total Environ. 643 (2018) 1562–1570. https://doi.org/10.1016/J.SCITOTENV.2018.06.314. [64] M. Milaković, G. Vestergaard, J.J. González-Plaza, I. Petrić, J. Kosić-Vukšić, I. Senta, S. Kublik, M. Schloter, N. Udiković- Kolić, Effects of industrial effluents containing moderate levels of antibiotic mixtures on the abundance of antibiotic resistance genes and bacterial community composition in exposed creek sediments, Sci. Total Environ. 706 (2020) 136001. https://doi.org/10.1016/J.SCITOTENV.2019.136001. [65] L. Charuaud, E. Jarde, A. Jaffrezic, M.F. Thomas, B. Le Bot, Veterinary pharmaceutical residues from natural water to tap water: Sales, occurrence and fate, J. Hazard. Mater. 361 (2019) 169–186. https://doi.org/10.1016/J.JHAZMAT.2018.08.075. [66] International Union of Pure and Applied Chemistry (IUPAC), Compendium of Chemical Terminology, 2014. [67] I. Jaciw-Zurakowsky, M.R. Snowdon, O.M. Schneider, Y.N. Zhou, R.L. Liang, Advanced oxidation processes using catalytic nanomaterials for air and water remediation, Nanomater. Air Remediat. (2020) 167–192. https://doi.org/10.1016/B978-0-12- 818821-7.00009-9. [68] X. Ao, W. Liu, Degradation of sulfamethoxazole by medium pressure UV and oxidants: Peroxymonosulfate, persulfate, and hydrogen peroxide, Chem. Eng. J. 313 (2017) 629–637. https://doi.org/10.1016/J.CEJ.2016.12.089. [69] W.H. Glaze, J.W. Kang, D.H. Chapin, The Chemistry of Water Treatment Processes Involving Ozone, Hydrogen Peroxide and Ultraviolet Radiation, Ozone Sci. Eng. 9 (1987) 335–352. https://doi.org/10.1080/01919518708552148. [70] D. Kanakaraju, B.D. Glass, M. Oelgemöller, Advanced oxidation process-mediated removal of pharmaceuticals from water: A review, J. Environ. Manage. 219 (2018) 189–207.
II. Introduction 87 https://doi.org/10.1016/J.JENVMAN.2018.04.103. [71] A.V. Emeline, V.N. Kuznetsov, V.K. Ryabchuk, N. Serpone, Heterogeneous Photocatalysis: Basic Approaches and Terminology, in: New Futur. Dev. Catal., 1st ed., Elsevier, 2013: pp. 1–47. https://doi.org/10.1016/B978-0-444-53872-7.00001-7. [72] V.J.P. Vilar, P. Alfonso-Muniozguren, J.P. Monteiro, J. Lee, S.M. Miranda, R.A.R. Boaventura, Tube-in-tube membrane microreactor for photochemical UVC/H2O2 processes: A proof of concept, Chem. Eng. J. 379 (2020) 122341. https://doi.org/10.1016/J.CEJ.2019.122341. [73] X. Jia, L. Lian, S. Yan, Y. Song, J. Nie, X. Zhu, W. Song, Comprehensive Understanding of the Phototransformation Process of Macrolide Antibiotics in Simulated Natural Waters, ACS ES&T Water. 1 (2021) 938–948. https://doi.org/10.1021/ACSESTWATER.0C00239. [74] X.H. Wang, A.Y.C. Lin, Phototransformation of cephalosporin antibiotics in an aqueous environment results in higher toxicity, Environ. Sci. Technol. 46 (2012) 12417–12426. https://doi.org/10.1021/ES301929E/SUPPL_FILE/ES301929E_ SI_001.PDF. [75] Directive 2008/105/EC of the European Parliament and of the Council of 16 December 2008 on environmental quality standards in the field of water policy, amending and subsequently repealing Council Directives 82/176/EEC, 83/513/EEC, 84/156/EEC, 84/491/EEC, Eur. Off. J. L348 (2008) 84–97. https://eur-lex.europa.eu/legalcontent/EN/TXT/PDF/?uri=CELEX:32008L0105&from=ES (accessed May 8, 2022). [76] E. Boyaci, Á. Rodríguez-Lafuente, K. Gorynski, F. Mirnaghi, É.A. Souza-Silva, D. Hein, J. Pawliszyn, Sample preparation with solid phase microextraction and exhaustive extraction approaches: Comparison for challenging cases, Anal. Chim.
LÚA VÁZQUEZ FERREIRO 88 Acta. 873 (2015) 14–30. https://doi.org/10.1016/J.ACA.2014.12.051. [77] L. Ramos, Critical overview of selected contemporary sample preparation techniques, J. Chromatogr. A. 1221 (2012) 84–98. https://doi.org/10.1016/J.CHROMA.2011.11.011. [78] H. Braus, F.M. Middleton, G. Walton, Organic Chemical Compounds in Raw and Filtered Surface Waters, Anal. Chem. 23 (1951) 1160–1164. https://pubs.acs.org/sharingguidelines (accessed May 8, 2022). [79] A. Andrade-Eiroa, M. Canle, V. Leroy-Cancellieri, V. Cerdà, Solid-phase extraction of organic compounds: A critical review. part ii, TrAC Trends Anal. Chem. 80 (2016) 655–667. https://doi.org/10.1016/J.TRAC.2015.08.014. [80] A. Andrade-Eiroa, M. Canle, V. Leroy-Cancellieri, V. Cerdà, Solid-phase extraction of organic compounds: A critical review (Part I), TrAC Trends Anal. Chem. 80 (2016) 641–654. https://doi.org/10.1016/J.TRAC.2015.08.015. [81] D. Sadutto, Y. Picó, Sample Preparation to Determine Pharmaceutical and Personal Care Products in an All-Water Matrix: Solid Phase Extraction, Molecules. 25 (2020) 5204. https://doi.org/10.3390/MOLECULES25215204. [82] C.F. Poole, Core concepts and milestones in the development of solid-phase extraction, Solid-Phase Extr. (2020) 1–36. https://doi.org/10.1016/B978-0-12-816906-3.00001-7. [83] Q. Zhou, J. Xiao, Y. Ding, Sensitive determination of fungicides and prometryn in environmental water samples using multiwalled carbon nanotubes solid-phase extraction cartridge, Anal. Chim. Acta. 602 (2007) 223–228. https://doi.org/10.1016/J.ACA.2007.09.038. [84] M.L. Hladik, K.L. Smalling, K.M. Kuivila, A multi-residue method for the analysis of pesticides and pesticide degradates in water using HLB solid-phase extraction and gas
II. Introduction 89 chromatography-ion trap mass spectrometry, Bull. Environ. Contam. Toxicol. 80 (2008) 139–144. https://doi.org/10.1007/S00128-007-9332-2. [85] S. fen Yuan, Z. hua Liu, H. Yin, Z. Dang, P. xiao Wu, N. wu Zhu, Z. Lin, Trace determination of sulfonamide antibiotics and their acetylated metabolites via SPE-LC-MS/MS in wastewater and insights from their occurrence in a municipal wastewater treatment plant, Sci. Total Environ. 653 (2019) 815–821. https://doi.org/10.1016/J.SCITOTENV.2018.10.417. [86] H. Tian, Determination of chloramphenicol, enrofloxacin and 29 pesticides residues in bovine milk by liquid chromatography– tandem mass spectrometry, Chemosphere. 83 (2011) 349–355. https://doi.org/10.1016/J.CHEMOSPHERE.2010.12.016. [87] M.R. Hadjmohammadi, S. Nazari, K. Kamel, Determination of flavonoid markers in honey with SPE and LC using experimental design, Chromatographia. 69 (2009) 1291–1297. https://doi.org/10.1365/S10337-009-1073-4/TABLES/8. [88] H.N. Mistri, A.G. Jangid, A. Pudage, A. Shah, P.S. Shrivastav, Simultaneous determination of sulfamethoxazole and trimethoprim in microgram quantities from low plasma volume by liquid chromatography–tandem mass spectrometry, Microchem. J. 94 (2010) 130–138. https://doi.org/10.1016/J.MICROC.2009.10.002. [89] H.X. Wang, B. Wang, Y. Zhou, Q.W. Jiang, Rapid and sensitive screening and selective quantification of antibiotics in human urine by two-dimensional ultraperformance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry, Anal. Bioanal. Chem. 406 (2014) 8049–8058. https://doi.org/10.1007/S00216-014-8197-6/FIGURES/2. [90] I. Martins, F.C. Carreira, L.S. Canaes, F.A. De Souza Campos Junior, L.M. Da Silva Cruz, S. Rath, Determination of parabens in shampoo using high performance liquid chromatography with amperometric detection on a boron-doped diamond electrode,
LÚA VÁZQUEZ FERREIRO 90 Talanta. 85 (2011) 1–7. https://doi.org/10.1016/J.TALANTA.2011.04.047. [91] C. Arthur, J. Pawliszy, Solid Phase Microextraction with Thermal Desorption Using Fused Silica Optical Fibers, Anal. Chem. 62 (1990) 2145–2148. https://pubs.acs.org/sharingguidelines (accessed May 8, 2022). [92] G. Ouyang, J. Pawliszyn, SPME in environmental analysis, Anal. Bioanal. Chem. 386 (2006) 1059–1073. https://doi.org/10.1007/S00216-006-0460-Z/FIGURES/13. [93] H. Prosen, L. Zupančič-Kralj, Solid-phase microextraction, TrAC Trends Anal. Chem. 18 (1999) 272–282. https://doi.org/10.1016/S0165-9936(98)00109-5. [94] J. Pawliszyn, Theory of Solid-Phase Microextraction, Handb. Solid Phase Microextraction. (2012) 13–59. https://doi.org/10.1016/B978-0-12-416017-0.00002-4. [95] B. Plutowska, T. Chmiel, T. Dymerski, W. Wardencki, A headspace solid-phase microextraction method development and its application in the determination of volatiles in honeys by gas chromatography, Food Chem. 126 (2011) 1288–1298. https://doi.org/10.1016/J.FOODCHEM.2010.11.079. [96] S. Seisonen, E. Kivima, K. Vene, Characterisation of the aroma profiles of different honeys and corresponding flowers using solid-phase microextraction and gas chromatography–mass spectrometry/olfactometry, Food Chem. 169 (2015) 34–40. https://doi.org/10.1016/J.FOODCHEM.2014.07.125. [97] M. Vila, M. Celeiro, J.P. Lamas, C. Garcia-Jares, T. Dagnac, M. Llompart, Simultaneous in-vial acetylation solid-phase microextraction followed by gas chromatography tandem mass spectrometry for the analysis of multiclass organic UV filters in water, J. Hazard. Mater. 323 (2017) 45–55. https://doi.org/10.1016/J.JHAZMAT.2016.06.056. [98] M. Llompart, M. Celeiro, C. García-Jares, T. Dagnac,
II. Introduction 91 Environmental applications of solid-phase microextraction, TrAC Trends Anal. Chem. 112 (2019) 1–12. https://doi.org/10.1016/J.TRAC.2018.12.020. [99] G. Alvarez-Rivera, M. Vila, M. Lores, C. Garcia-Jares, M. Llompart, Development of a multi-preservative method based on solid-phase microextraction–gas chromatography–tandem mass spectrometry for cosmetic analysis, J. Chromatogr. A. 1339 (2014) 13–25. https://doi.org/10.1016/J.CHROMA.2014.02.075. [100] A. Roszkowska, N. Miękus, T. Bączek, Application of solidphase microextraction in current biomedical research, J. Sep. Sci. 42 (2019) 285–302. https://doi.org/10.1002/JSSC.201800785. [101] A. Kabir, K.G. Furton, Fabric phase sorptive extractors (US9557252B2), 2014. [102] E. Zilfidou, A. Kabir, K.G. Furton, V. Samanidou, Fabric Phase Sorptive Extraction: Current State of the Art and Future Perspectives, Separations. 5 (2018) 40. https://doi.org/10.3390/SEPARATIONS5030040. [103] M. Celeiro, R. Acerbi, A. Kabir, K.G. Furton, M. Llompart, Development of an analytical methodology based on fabric phase sorptive extraction followed by gas chromatographytandem mass spectrometry to determine UV filters in environmental and recreational waters, Anal. Chim. Acta X. 4 (2020) 100038. https://doi.org/10.1016/J.ACAX.2019.100038. [104] A. Kabir, R. Mesa, J. Jurmain, K.G. Furton, Fabric Phase Sorptive Extraction Explained, Separations. 4 (2017) 21. https://doi.org/10.3390/SEPARATIONS4020021. [105] M. Locatelli, N. Tinari, A. Grassadonia, A. Tartaglia, D. Macerola, S. Piccolantonio, E. Sperandio, C. D’Ovidio, S. Carradori, H.I. Ulusoy, K.G. Furton, A. Kabir, FPSE-HPLC- DAD method for the quantification of anticancer drugs in human whole blood, plasma, and urine, J. Chromatogr. B. 1095 (2018)
LÚA VÁZQUEZ FERREIRO 92 204–213. https://doi.org/10.1016/J.JCHROMB.2018.07.042. [106] E. Karageorgou, N. Manousi, V. Samanidou, A. Kabir, K.G. Furton, Fabric phase sorptive extraction for the fast isolation of sulfonamides residues from raw milk followed by high performance liquid chromatography with ultraviolet detection, Food Chem. 196 (2016) 428–436. https://doi.org/10.1016/J.FOODCHEM.2015.09.060. [107] R. Kaur, R. Kaur, S. Rani, A.K. Malik, A. Kabir, K.G. Furton, Application of fabric phase sorptive extraction with gas chromatography and mass spectrometry for the determination of organophosphorus pesticides in selected vegetable samples, J. Sep. Sci. 42 (2019) 862–870. https://doi.org/10.1002/JSSC.201800854. [108] H.İ. Ulusoy, K. Köseoğlu, A. Kabir, S. Ulusoy, M. Locatelli, Fabric phase sorptive extraction followed by HPLC-PDA detection for the monitoring of pirimicarb and fenitrothion pesticide residues, Microchim. Acta. 187 (2020) 1–11. https://doi.org/10.1007/S00604-020-04306-7/TABLES/3. [109] S.A. Barker, A.R. Long, C.R. Short, Isolation of drug residues from tissues by solid phase dispersion, J. Chromatogr. A. 475 (1989) 353–361. https://doi.org/10.1016/S0021-9673(01)89689- 8. [110] S.A. Barker, Matrix solid-phase dispersion, J. Chromatogr. A. 885 (2000) 115–127. https://doi.org/10.1016/S0021- 9673(00)00249-1. [111] M. Celeiro, E. Guerra, J.P. Lamas, M. Lores, C. Garcia- Jares, M. Llompart, Development of a multianalyte method based on micro-matrix-solid-phase dispersion for the analysis of fragrance allergens and preservatives in personal care products, J. Chromatogr. A. 1344 (2014) 1–14 . https://doi.org/10.1016/J.CHROMA.2014.03.070. [112] E.M. Kristenson, L. Ramos, U.A.T. Brinkman, Recent advances
II. Introduction 93 in matrix solid-phase dispersion, TrAC Trends Anal. Chem. 25 (2006) 96–111. https://doi.org/10.1016/J.TRAC.2005.05.011. [113] L. Sanchez-Prado, J.P. Lamas, G. Alvarez-Rivera, M. Lores, C. Garcia-Jares, M. Llompart, Determination of suspected fragrance allergens in cosmetics by matrix solid-phase dispersion gas chromatography–mass spectrometry analysis, J. Chromatogr. A. 1218 (2011) 5055–5062. https://doi.org/10.1016/J.CHROMA.2011.06.013. [114] Z. Wang, R. Sun, Y. Wang, N. Li, L. Lei, X. Yang, A. Yu, F. Qiu, H. Zhang, Determination of phenolic acids and flavonoids in raw propolis by silica-supported ionic liquid-based matrix solid phase dispersion extraction high performance liquid chromatography-diode array detection, J. Chromatogr. B. 969 (2014) 205–212. https://doi.org/10.1016/J.JCHROMB.2014.08.022. [115] A. Salemi, E. Shafiei, M. Vosough, Optimization of matrix solid phase dispersion coupled with gas chromatography electron capture detection for determination of chlorinated pesticides in soil, Talanta. 101 (2012) 504–509. https://doi.org/10.1016/J.TALANTA.2012.10.009. [116] A. Balsebre, M.E. Báez, J. Martínez, E. Fuentes, Matrix solidphase dispersion associated to gas chromatography for the assessment in honey bee of a group of pesticides of concern in the apicultural field, J. Chromatogr. A. 1567 (2018) 47–54. https://doi.org/10.1016/J.CHROMA.2018.06.062. [117] N. Carro, L. Vilas, I. García, M. Ignacio, A.M. Mouteira, Optimization of a method based on micro-matrix solid-phase dispersion (micro-MSPD) for the determination of PCBs in mussel samples, Anal. Chem. Res. 11 (2017) 1–8. https://doi.org/10.1016/J.ANCR.2016.11.003. [118] N. Carro, A. Mouteira, I. García, M. Ignacio, J. Cobas, Fast determination of phthalates in mussel samples by micro-matrix solid-phase dispersion (micro-MSPD) coupled with GC–
LÚA VÁZQUEZ FERREIRO 94 MS/MS, J. Anal. Sci. Technol. 12 (2021) 1–11. https://doi.org/10.1186/S40543-021-00303-4/TABLES/5. [119] E. Guerra, M. Celeiro, J.P. Lamas, M. Llompart, C. Garcia-Jares, Determination of dyes in cosmetic products by micro-matrix solid phase dispersion and liquid chromatography coupled to tandem mass spectrometry, J. Chromatogr. A. 1415 (2015) 27– 37. https://doi.org/10.1016/J.CHROMA.2015.08.054. [120] A. Lončarić, K. Matanović, P. Ferrer, T. Kovač, B. Šarkanj, M.S. Babojelić, M. Lores, Peel of Traditional Apple Varieties as a Great Source of Bioactive Compounds: Extraction by Micro- Matrix Solid-Phase Dispersion, Foods. 9 (2020) 80. https://doi.org/10.3390/FOODS9010080. [121] G. Alvarez-Rivera, M. Llompart, C. Garcia-Jares, M. Lores, Identification of unwanted photoproducts of cosmetic preservatives in personal care products under ultraviolet-light using solid-phase microextraction and micro-matrix solid-phase dispersion, J. Chromatogr. A. 1390 (2015) 1–12. https://doi.org/10.1016/J.CHROMA.2015.02.056. [122] M.D. Luque de Castro, F. Priego Capote, Analytical applications of ultrasound, 1st ed., Elsevier, 2007. [123] Y. Picó, Ultrasound-assisted extraction for food and environmental samples, TrAC Trends Anal. Chem. 43 (2013) 84–99. https://doi.org/10.1016/J.TRAC.2012.12.005. [124] C. Wen, J. Zhang, H. Zhang, C.S. Dzah, M. Zandile, Y. Duan, H. Ma, X. Luo, Advances in ultrasound assisted extraction of bioactive compounds from cash crops – A review, Ultrason. Sonochem. 48 (2018) 538–549. https://doi.org/10.1016/J.ULTSONCH.2018.07.018. [125] F. Chemat, N. Rombaut, A.G. Sicaire, A. Meullemiestre, A.S. Fabiano-Tixier, M. Abert-Vian, Ultrasound assisted extraction of food and natural products. Mechanisms, techniques, combinations, protocols and applications. A review, Ultrason.
III. METHODOLOGY
III. Methodology 103 The methodologies used throughout this thesis were based on sample preparation procedures that, as far as possible, should be miniaturized, simple, fast, low-cost, environmentally friendly and easy to implement in any laboratory. Some of the procedures were based on solid-phase extraction technique that was used for the analysis of antibiotics in wastewater and natural water. This extraction technique was also applied for the determination of fungicides in water, in this case using by-products as an alternative and sustainable sorbent. Solid-phase microextraction (SPME) was optimized for the analysis of sixty personal care products (PCPs) in hydroalcoholic gels and, miniaturized SPME was applied for the determination of volatile and semi-volatile compounds in honey. In addition, micro-matrix solid-phase dispersion (µMSPD) was employed for the analysis of seventy-eight PCPs in cosmetic products of different nature and fabric phase sorptive extraction (FPSE), which can be considered as a combination of SPME and SPE, was used to determine fungicides in environmental waters. On the other hand, as regards the analysis of fungicides in vine leaves as well as in grapes and soils, ultrasound assisted extraction (UAE) was utilized. This technique was also employed after vortex extraction (VE) to extract phenolic compounds from honey. Chemometric tools were used for the optimization of the extraction efficiency of the sample preparation protocols mentioned above as well as for the result interpretation. These tools included design of experiments (DOE), analysis of variance (ANOVA), multiple-range least significant difference (LSD) tests and principal component analysis (PCA). Instrumental determination was carried out employing chromatography coupled to mass spectrometry. Gas chromatography (GC) followed by mass spectrometry (MS) and tandem mass spectrometry (MS/MS) was used. Liquid chromatography (LC) coupled to MS/MS was also employed, and ultra-high performance LC (UHPLC) followed by high resolution mass spectrometry (HRMS), employing a single or triple quadrupole time-of-flight, was applied for target and non-target
LÚA VÁZQUEZ FERREIRO 104 analysis operating in Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra (SWATH) acquisition mode. In addition, the total phenolic content (TPC) and antioxidant activity (AA) of honey were measured by means of an ultraviolet-visible (UV- Vis) spectrophotometer. As regards photodegradation experiments, a static laboratory-scale photoreactor using UVC radiation and advanced oxidation processes (AOPs), employing a tube-in-tube membrane reactor operating in continuous mode, were also tested for the removal of antibiotics in water.
IV. RESULTS AND DISCUSSION
CHAPTER 1. DETERMINATION OF FUNGICIDES IN AGRICULTURAL AND ENVIRONMENTAL SAMPLES
IV. Results and discussion 213 In addition to this compound, other two by-products could be identified for each of the following macrolides: clarithromycin, erythromycin and roxithromycin. It is important to note that for Clar-3 (C38H69NO15, m/z 780.474), two possible chemical structures (Clar-3a and Clar-3b) were proposed, which correspond to two isomeric structures that cannot be distinguished by HRMS. It is worth noting that most of the obtained transformation products with the tube-in-tube membrane reactor working in continuous mode, except Clar-3 and Rox-3, were also formed after UVC radiation in the lab-scale photoreactor (see Chapter 4.1). 4. Conclusions The operational conditions of a tube-in-tube membrane by applying different oxidant-catalyst combinations (either liquid or gaseous oxidants), under continuous mode and low residence time, have been optimized employing demineralized water. The photoreactor versatility was also demonstrated for the removal of a mixture of 14 antibiotics in an urban wastewater after secondary treatment. The best treatment performance was achieved with O3 treatment (removal >70% for all antibiotics and >95% for 12 of the 14), followed by UVC/Ag2MoO4/S2O82- (>60% removal for 5 of the 14 antibiotics). Finally, a tentative identification of degradation by-products has been also carried out, demonstrating the presence of seven macrolide transformation products during the ozonation process and one from ciprofloxacin/ofloxacin using the UVC/Ag2MoO4/S2O82- system. Therefore, the tube-in-tube membrane reactor offers a suitable and high throughput system for the antibiotic removal, as it allows high degradation rates without forming too many degradation by-products.
LÚA VÁZQUEZ FERREIRO 214 Acknowledgments This research was supported by projects EQC2018-005011-P (Ministry of Science, Innovation and Universities, Spain), IGDC-1E-2026 (Infrastructure Program, MINECO, Spain), Base Funding – UIDB/50020/2020 of the Associate Laboratory LSRE-LCM – funded by national funds through FCT/MCTES (PIDDAC), the Galician Competitive Research Groups IN607B 2019/13 and ED431 2020/06 (Xunta de Galicia). L. Vazquez acknowledges the support of the European Grouping of Territorial Cooperation Galicia-Norte Portugal (GNP, EGTC) under the IACOBUS Program and V.J.P. Vilar acknowledges the FCT Individual Call to Scientific Employment Stimulus 2017 (CEECIND/01317/2017). We would like to thank D.G.D. Rocca and R.F.P.M. Moreira from the Federal University of Santa Catarina (Brazil), for providing the Ag2MoO4 catalyst. References [1] A.B. Zeidman, O.M. Rodriguez-Narvaez, J. Moon, E.R. Bandala. Removal of antibiotics in aqueous phase using silica-based immobilized nanomaterials: A review. Environmental Technology & Innovation, 20 (2020), 101030. [2] R. Loos, D. Marinov, I. Sanseverino, D. Napierska, T. Lettieri, T. Review of the 1st Watch List under the Water Framework Directive and recommendations for the 2nd Watch List. European Commission: Luxembourg (2018). [3] E.M. Cuerda-Correa, M.F. Alexandre-Franco, C. Fernández- González, C. (2019). Advanced oxidation processes for the removal of antibiotics from water. An overview. Water, 12(1) (2019), 102. [4] A. Diório, J. Díaz-Angulo, R.M. Castellanos, A.I. Gomes, R. Bergamasco, M.F. Vieira, M. Dezotti, M.A. Mueses, F. Machucha- Martinez, V.J.P. Vilar. A tubular ceramic membrane coated with TiO2- P25 for radial addition of H2O2 towards AMX removal from synthetic
IV. Results and discussion 215 solutions and secondary urban wastewater. Environmental Science and Pollution Research (2021), 1-10. [5] E.C. Lumbaque, D.S. Lüdtke, D.D. Dionysiou, V.J.P Vilar, C. Sirtori. Tube-in-tube membrane photoreactor as a new technology to boost sulfate radical advanced oxidation processes. Water Research, 191 (2021), 116815. [6] L.Yang, L. Xu, X. Bai, P. Jin. Enhanced visible-light activation of persulfate by Ti3+ self-doped TiO2/graphene nanocomposite for the rapid and efficient degradation of micropollutants in water. Journal of hazardous materials, 365 (2019), 107-117. [7] Z. Liu, K. Demeestere, S. Van Hulle. Comparison and performance assessment of ozone-based AOPs in view of trace organic contaminants abatement in water and wastewater: a review. Journal of Environmental Chemical Engineering, 9(4) (2021), 105599. [8] V.J.P. Vilar, P. Alfonso-Muniozguren, J.P. Monteiro, J. Lee, S.M. Miranda, R.A.R. Boaventura. Tube-in-tube membrane microreactor for photochemical UVC/H2O2 processes: a proof of concept. Chemical Engineering Journal., 379 (2020), 122341, 10.1016/J.CEJ.2019.122341 [9] R.M. Castellanos, J. Paulo Bassin, M. Dezotti, R.A.R. Boaventura, V.J.P. Vilar. Tube-in-tube membrane reactor for heterogeneous TiO2 photocatalysis with radial addition of H2O2. Chemical Engineering Journal, 395 (2020), 124998 [10] E.C. Lumbaque, C. Sirtori, V.J.P. Vilar. Heterogeneous photocatalytic degradation of pharmaceuticals in synthetic and real matrices using a tube-in-tube membrane reactor with radial addition of H2O2. Science of The Total Environment, 743 (2020), 140629. [11] J. Díaz-Angulo, S. Cotillas, A.I. Gomes, S.M. Miranda, M. Mueses, F. Machuca-Martínez, M.A. Rodrigo, R. Boaventura, V.J.P. Vilar. A tube-in-tube membrane microreactor for tertiary treatment of
LÚA VÁZQUEZ FERREIRO 216 urban wastewaters by photo-Fenton at neutral pH: a proof of concept. Chemosphere, 263 (2021), 128049. [12] X. Ao, W. Liu. Degradation of sulfamethoxazole by medium pressure UV and oxidants: peroxymonosulfate, persulfate, and hydrogen peroxide. Chemical Engineering Journal, 313 (2017), 629- 637. [13] K. González-Labrada, R. Richard, C. Andriantsiferana, H. Valdés, U.J. Jáuregui-Haza, M.H. Manero. Enhancement of ciprofloxacin degradation in aqueous system by heterogeneous catalytic ozonation. Environmental Science and Pollution Research, 27(2) (2020), 1246- 1255. [14] M. Pirsaheb, H. Hossaini, H. Janjani. Reclamation of hospital secondary treatment effluent by sulfate radicals based–advanced oxidation processes (SR-AOPs) for removal of antibiotics. Microchemical Journal, 153 (2020), 104430. [15] R. Nogueira, M. Oliveira, W. Paterlini. Simple and fast spectrophotometric determination of H2O2 in photo-Fenton reactions using metavanadate. Talanta, 66 (2005), 86-91, [16] C. Liang, C.F. Huang, N. Mohanty, R.M. Kurakalva. A rapid spectrophotometric determination of persulfate anion in ISCO. Chemosphere, 73 (2008), 1540-1543. [17] R.M. Castellanos, P.H. Presumido, M. Dezotti, V.J.P. Vilar. Ultrafiltration ceramic membrane as oxidant-catalyst/water contactor to promote sulfate radical AOPs: a case study on 17β-estradiol and 17α- ethinylestradiol removal. Environmental Science and Pollution Research (2021), 1-11. [18] A.G. Trovó, R.F.P. Nogueira, A. Agüera, C. Sirtori, A.R. Fernández-Alba AR Photodegradation of sulfamethoxazole in various aqueous media: Persistence, toxicity and photoproducts assessment. Chemosphere, 77 (2009), 1292–1298.
IV. Results and discussion 217 [19] M. Sturini, A. Speltini, F. Maraschi, A. Profumo, L. Pretali, E.A. Irastorza, E. Fasani, A. Albini. Photolytic and photocatalytic degradation of fluoroquinolones in untreated river water under natural sunlight. Applied Catalysis B: Environmental 119–120 (2012), 32–39. [20] C. Sirtori, A. Agüera, W. Gernjak, S. Malato Effect of watermatrix composition on Trimethoprim solar photodegradation kinetics and pathways. Water Research , 44 (2010), 2735–2744. [21] F. Wang, Y. Feng, P. Chen, Y. Wang, Y. Su, Q. Zhang, Y. Zeng, Z. Xie, H. Liu, Y. Liu, W. Lv, G. Liu. Photocatalytic degradation of fluoroquinolone antibiotics using ordered mesoporous g-C3N4 under simulated sunlight irradiation: Kinetics, mechanism, and antibacterial activity elimination. Applied Catalysis B: Environmental, 227 (2018), 114–122. [22] X.H. Wang, A.Y.C. Lin. Phototransformation of cephalosporin antibiotics in an aqueous environment results in higher toxicity. Environmental Science & Technology, 46 (2012), 12417–12426. [23] H.G. Guo, N.Y. Gao, W.H. Chu, L. Li, Y.J. Zhang, J.S. Gu, Y.L. Gu. Photochemical degradation of ciprofloxacin in UV and UV/H2O2 process: Kinetics, parameters, and products. Environmental Science and Pollution Research, 20 (2013), 3202–3213. [24] T. Haddad, K. Kümmerer. Characterization of phototransformation products of the antibiotic drug Ciprofloxacin with liquid chromatography–tandem mass spectrometry in combination with accurate mass determination using an LTQ-Orbitrap. Chemosphere, 115 (2014), 40–46. [25] X. Jia, L. Lian, S. Yan, Y. Song, J. Nie, X. Zhu W. Song. Comprehensive Understanding of the Phototransformation Process of Macrolide Antibiotics in Simulated Natural Waters. Environmental Science & Technology, Water, 1 (2021), 938–948.
LÚA VÁZQUEZ FERREIRO 218 [26] Y. Song, J. Tian, S. Gao, P. Shao, J. Qi, F. Cui Photodegradation of sulfonamides by g-C3N4 under visible light irradiation: Effectiveness, mechanism and pathways. Applied Catalysis B: Environmental, 210 (2017), 88–96. [27] Z. Zhang, X. Xie, Z. Yu, H. Cheng. Influence of chemical speciation on photochemical transformation of three fluoroquinolones (FQs) in water: Kinetics, mechanism, and toxicity of photolysis products. Water Research, 148 (2019), 19–29. https://doi.org/10.1016/J.WATRES.2018.10.027
V. GENERAL DISCUSSION
V. General discussion 229 phenolic content (TPC) and the antioxidant activity (AA) employing an UV-Vis spectrophotometer. SPME is one the preferred extraction techniques for the analysis of volatile and semi-volatile compounds in honey. However, with the aim of minimize the cost, the amount of sample and waste generation, the SPME miniaturization (mini_SPME), enabling the use of a very small amount of honey (200 mg), seemed a good option, since the chromatographic responses were quite comparable when using 10 times more sample (2 g). A mixed level fractional factorial DOE (3·23−1 + 2 central points) was employed to evaluate four critical parameters that could affect the mini_SPME effectiveness for the determination of 24 selected compounds: temperature, fibre coating, salting out effect (addition of NaCl, w/v) and dilution in water (w/v). The method was validated achieving good linearity, LODs and LOQs and precision. In order to assess the method accuracy, recovery experiments were conducted in four different types of honey (multifloral, honeydew, chestnut and heather honey). Finally, the optimized method was applied for the identification of the 24 previous selected compounds and quantification of 9 of them in a broad range of honeys from Galicia and foreign countries (France, Greece, Italy and Kazakhstan). The botanical origin of the analysed honey samples was multifloral, honeydew, chestnut, heather, blackberry, eucalyptus, orange, thyme and lavender. In addition, a preliminary study was conducted to identify non-target species. Nevertheless, a statistical approach would be further necessary to check whether the compounds could be considered as markers for Galician honeys. On the other hand, a methodology which combines VE with UAE, utilizing aqueous based solvents, was employed for the evaluation of phenolic compounds in honey. Since honey is a complex matrix, SPE is usually employed to remove matrix components such as polysaccharides. Nevertheless, in this investigation, after a previous optimization, external calibration was employed and accuracy was assessed fortifying a multifloral honey with the 41 target phenolic compounds, including aldehydes, acids, flavonoids (flavonols, flavones…) and coumarins, applying a quite simple and fast strategy.
LÚA VÁZQUEZ FERREIRO 230 Twenty-five of the 41 target compounds were identified and quantified in the analysed samples. In addition, TPC and AA were also evaluated according to modified protocols previously reported using a UV-Vis spectrophotometer. A chemometric study has been carried out employing statistical tools such as ANOVA and principal component analysis (PCA) to obtain models that allowed classifying 91 different Galician honeys according to their botanical origin, including multifloral, honeydew, heather, chestnut, chestnut/honeydew, blackberry and eucalyptus honeys. These studies were based on TPC, AA, individual phenolic concentration and/or ∑phenolic compounds showing significant differences depending on the honey variety. Hence, despite the complexity of the matrix, both proposed methods, the first one to identify and quantify volatile and semi-volatile compounds and the second one relying on phenolic compounds, proved to be suitable. The powerful of chemometric tools was demonstrated to differentiate the honey variety employing the TPC and AA indexes and the phenolic compound contents. However, results did not allow differentiating Galician honeys from other foreign honeys, although they allowed distinguishing between the different honey varieties. In addition, a more in-depth study in which a larger number of samples would be analysed would be necessary to find significant differences, especially for volatiles and semi-volatile compounds. 3.- Chapter 3. Determination of personal care products (PCPs) in cosmetic formulations Cosmetics products are defined by the Regulation EC No 1223/2009 as “any substance or mixture intended to be placed in contact with the external parts of the human body (epidermis, hair system, nails, lips and external genital organs) or with the teeth and the mucous membranes of the oral cavity with a view exclusively or mainly to cleaning them, perfuming them, changing their appearance, protecting them, keeping them in good condition or correcting body odours”. In this context, as it is well known, cosmetics such as make up, hair-care products, creams, among others, are widely used consumer products all
V. General discussion 231 over the world. Besides, nowadays, one of the most frequently daily used products are hydroalcoholic gels, since they became essential to prevent the spread of COVID-19 virus and they are massively employed for the general population and several times every day. A large number of organic compounds, considered personal care products (PCPs), are present in cosmetic formulations, such as fragrance allergens, preservatives, plasticizers, synthetic musks, and ultraviolet (UV) filters, among others. Fragrances (allergens and synthetic musks), usually added to cosmetics with the intention of providing a pleasant scent, are the main responsible of allergic contact dermatitis. UV filters are intended to protect consumers against the harmful solar radiation and their presence is especially important in sunscreens, but they can also be found in a broad range of daily care products. Preservatives are added to cosmetic formulations to protect products and consumers against microbial growth, whereas plasticizers can be added to the product or transferred from the plastic containers to the product. The presence of most of these compounds in cosmetics is associated with contact allergies, skin dermatitis and even, in some cases, carcinogenic effects and endocrine dysfunction. Cosmetic products marketed (whether produced in the EU or not) in the European Union must follow the applicable legislation. Therefore, they must comply with Regulation EC No 1223/2009, and this compliance must be verifiable from an analytical point of view. In this context, cosmetics analysis is a challenge task due to the wide variety and complexity of the samples, composed by a high number of substances of different nature. Two analytical methodologies involving the use of µMSPD and SPME to determine a high number of PCPs in cosmetics of different nature were developed. In both cases, the PCPs were analysed by GC according to the chemical nature of the target analytes and MS/MS detection in SRM mode was chosen to improve analytical selectivity and sensitivity. A methodology based on µMSPD was optimized for the analysis of 14 multiclass UV filters. This is a very novel approach as this technique
LÚA VÁZQUEZ FERREIRO 232 has never been applied for the extraction of these substances in cosmetic formulations. Factors affecting the process such as the dispersing agent, and volume and type of elution solvent were studied by means of a DOE. In this case, a multifactor categorical 4·22 design involving 16 randomized experiments was selected. Once the method was optimized, the µMSPD-GC-MS/MS performance was assessed and extended to other PCPs, such as fragrance allergens, synthetic musks, preservatives and plasticizers, reaching 78 PCPs. The method showed good linearity and precision. Recovery studies were carried out fortifying a moisturizing hand cream, and the obtained results ranged from 70 to 110 % for all compounds. The fast and green developed method demonstrated high throughput and suitability, allowing the simultaneous analysis in a single extraction of 78 compounds with very different chemical nature, in a wide variety of cosmetic products (sunscreens, creams, make up, lipsticks…). Regarding the analysis of hydroalcoholic gels, until the development of the present method, SPME had never been applied for the simultaneous extraction of multianalyte PCPs in cosmetic samples, including in this case 60 compounds, such as fragrance allergens, synthetic musks, preservatives and plasticizers. For the optimization of this protocol, a multifactorial categorical design (3·22) was carried out evaluating the main factors affecting the sample preparation step and their interactions. The parameters included in the DOE were the fibre coating, the extraction mode and the temperature. Under the optimized conditions, the SPME-GC-MS/MS method was validated in terms of linearity, precision and accuracy, achieving good results and following as far as possible the application of the ISO 12787 international standard “Cosmetics–Analytical methods–Validation criteria for analytical results using chromatographic techniques”. After that, the method was applied to real hydroalcoholic gel samples in order to assess their compliance with the applicable legislation (Regulation EC No 1223/2009), as well as with the World Health Organization recommendations to homogenise the hydroalcoholic gel formulation and fabrication, assuring their antimicrobial properties.
V. General discussion 233 Thus, both methodologies were simple, suitable, green, and fast allowing the determination of a high number of PCPs in cosmetic products of different nature. In both cases, matrix calibration was not required, which further simplifies the procedures facilitating their use in any routine laboratory. The presence of prohibited compounds in different cosmetic products, according to EC Regulation No. 1223/2009, was demonstrated, as well as that of fragrance allergens at concentrations above the label limit (10 μg g−1) in hydroalcoholic gels. Furthermore, none of the formulations of the analysed samples of hand sanitizers complied with the WHO recommendations. Although, hydroalcoholic gels can be considered a borderline product, results showed that they the analysed sample were cosmetics and not biocidal products. Therefore, the obtained results revealed the need for a greater control over cosmetic products to ensure consumer safety without causing undesirable side effects. 4.- Chapter 4. Determination of antibiotics in water and degradation studies Due to the increasing use of pharmaceuticals by the population and in veterinary medicine, their presence and persistence in water is growing. Among these compounds, one of the most interesting groups is the antibiotics, which can cause microbial resistance due to irresponsible and irrational uses. As they are only partially removed in wastewater treatment plants, these substances continuously enter the environment, posing a significant risk not only to the aquatic ecosystem, but also to human health. Thus, alternative procedures such as photodegradation and advanced oxidation processes (AOPs) seem to be good options for the efficient removal of antibiotics and other emerging pollutants. SPE was employed for the isolation of 14 multi-class antibiotics in wastewaters and natural water, including macrolides, cephalosporins, fluoroquinolones, sulfonamides and diaminopyrimidines. The analysis was carried out by two approaches based on high-resolution mass spectrometry, employing a simple and a triple quadrupole-time of flight detectors, coupled to ultra-high performance liquid chromatography.
LÚA VÁZQUEZ FERREIRO 234 The extraction method was optimized evaluating different parameters such as sample pH, amount of sample and solvent, and the SPE cartridge, which consisted in this case of a conventional hydrophiliclipophilic sorbent, well known under the commercial name of Oasis HLB (Waters company). Under the optimal conditions, the method was validated achieving good linearity, precision and LODs and LOQs. The recovery values were satisfactory in ultrapure water, being above 80 % except for two macrolides, azithromycin and erythromycin. Therefore, experiments were conducted to evaluate whether the low values were due to a low extraction efficiency or to matrix effects into the MS ionization source. For this purpose, responses of fortified extracts before and after the SPE process were compared, showing that there was no significant ionization suppression into the source, but the poor retention capacity of the sorbent was responsible of the low recoveries. Additionally, recovery studies in four different real matrices (urban and hospital effluents, well water and river water) were conducted, observing that the type of water matrix influenced the extraction performance. The recovery percentages particularly decreased for the most complex matrices (urban and hospital wastewater), consequently the use of isotopically labelled surrogates deemed necessary. After that, the target antibiotics were quantified in wastewater and natural waters. To analyse the target antibiotics, an ultra-high performance liquid chromatography coupled to a quadrupole time-of-flight (UHPLC- QToF) mass spectrometer was used. Another high-resolution mass spectrometry configuration was utilized for conducting non-target studies, employing a SCIEX TripleTOF (QqTof) instrument in SWATHTM (sequential windowed acquisition of all theoretical mass spectra) mode. The SWATH workflow is based on the selection of a m/z range in which all analytes are included, then the range is divided into numerous small m/z windows (typically between 20 and 30) and MS/MS spectra are registered for all the detected peaks. In this way, since a TOF full scan and MS/MS spectra for all peaks are obtained simultaneously, it is not necessary to introduce mass transitions or expected masses in the acquisition method. One of the powerful features enabled by this scanning mode is the possibility to perform non-target retrospective searches using the same raw acquisition files.
V. General discussion 235 This approach allowed to identify up to 94 non-target chemical compounds, including another antibiotics, but also drugs, pesticides…, taking into account the exact masses of the unknown eluted compounds and other additional confirmation criteria such as the isotope profile and library score calculated with high-resolution MS and MS/MS spectra, providing a final combined score. On the other hand, since the occurrence of the target antibiotics was demonstrated in real water samples, suggesting that they can easily reach the aquatic environment, the use and improvement of water decontamination procedures is of great interest to protect the environment and human health. As such, a preliminary study dealing with the simultaneous photodegradation of the 14 target multi-class antibiotics employing a lab-scale reactor with two UVC lamps has been carried out. Results showed that photodegradation seemed to be a useful option for the removal of most of the target antibiotics in ultrapure water. However, studies in other real water matrices are also needed as well as other investigations including advanced oxidation processes (AOPs), since they could lead to efficient and novel procedures. In this context, a low footprint tube-in-tube membrane reactor based on AOPs working in continuous mode has been tested for the removal of target antibiotics in both demineralised water (DW) and urban wastewater (UWW). The operating conditions have been optimized by evaluating different parameters such as liquid (H2O2, S2O82-) and gaseous (O3) oxidants, highlighting that it is the first time that a gaseous oxidant is proposed for this type of reactor. In addition, the catalyst (Ag2MoO4 or TiO2), the use of UVC radiation, and sample flow rate were also assessed. It is also important to mention that Ag2MoO4 had never been proposed as a catalyst for the tube-in-tube membrane reactor. Promising removal efficiency was obtained not only for DW, but also for UWW. On the other hand, by-products may be formed during the degradation processes, so that their identification is also of great importance, as well as the investigation of their formation route. In this thesis, a tentative identification was conducted in HRMS by implementing a SWATH acquisition, being able to find and identify up to 20 photoproducts after applying UVC radiation and 8 after
LÚA VÁZQUEZ FERREIRO 236 employing the tube-in-tube membrane reactor (1 for UVC/Ag2MoO4/S2O82- treatment and 7 for the ozonation process). It is worth noting that most degradation studies and the subsequent identification of possible by-products are usually carried out for only few antibiotics and for compounds of the same family, although cooccurrence of antibiotics is very frequent in the environment. As an example, the tube-in-tube membrane reactor has never been applied for the simultaneous degradation of more than four pharmaceuticals. Hence, to summarize briefly, seven different sample preparation techniques (FPSE, SPE, UAE, SPME, VE, MSPD and MAE) were tested along the present thesis. As common characteristics, all the optimized methods and extraction techniques follow as much as possible the principles of “green analytical chemistry”, demonstrating their suitability for the analysis of different matrices. As an example, SPME was feasible both for the extraction of volatile and semi-volatile compounds in honey as well as for a wide variety of PCPs in cosmetic formulations, such as hydroalcoholic gels. In all cases, an attempt was made to minimize the amounts of sample and solvents employed, so that all procedures were as environmentally friendly, simple and miniaturized as possible. Besides, they were of easy implementation in any laboratory and some of them of easy automation, such as SPE or SPME. On the other hand, six matrices of quite different nature were considered, including environmental, agronomic, food and cosmetic samples. Among the environmental ones, a wide variety of waters were analysed, such as rainwater, irrigation water, river, well water, urban and hospital wastewaters, and others utilized for recovery studies (tap water, spring water, fountain water, etc). In addition, the presence of fungicides was evaluated in soil samples and in food, leaves and grapes. These compounds were also determined in tea samples. Nevertheless, honey was the main food matrix characterized, being probably the most complex one to handle during this thesis, since its high viscosity makes difficult to work with. Finally, the cosmetic products that were included in this thesis involved creams (moisturizing facial cream, vitalizing
V. General discussion 237 cream…), leave-on hair serum, sunscreens, make-ups, lipstick and solar stick. In addition, hydroalcoholic gels were also analysed, due to their frequent use to prevent and mitigate SARS-CoV-2 virus dissemination during Covid-19 pandemic. Therefore, it is important to highlight the complexity that comes from the optimization of so many sample preparation techniques for such a wide variety of matrices. In addition, the fact that these methods are multi-analyte, up to 78 target compounds in some of the investigations, makes the optimization and analysis more complex. It should be taken into account that more than 150 target compounds have been considered and that non-target compounds and photodegradation by-products have been identified, as well. All the proposed analytical methodologies published in scientific papers and included in this thesis were validated. Linearity was assessed and external calibration was adequate for all the methods developed, although for complex matrices, compounds acting as internal standards and isotopically labelled surrogates were considered necessary (i.e. honey, wastewaters). The adequacy of the developed methods to detect trace and ultra-trace levels with sufficient confidence has been demonstrated, achieving low LODs and LOQs. In addition, these methods showed good precision, with satisfactory results for both interday (reproducibility) and intra-day (repeatability). Recovery studies were also carried out in different matrices and at different concentration levels in most cases, demonstrating the accuracy of the developed methods. In addition, all the methodologies were applied to real samples for each class of compounds, demonstrating in all cases the occurrence of some of the target analytes. Besides, the quantification of the target substances has been carried out and the observed concentration levels were compared with those included in the legislation in force, where applicable. On the other hand, the great potential of chemometric tools has been again demonstrated. In most of the investigations, DOE was used to simultaneously evaluate the influence of critical parameters affecting the extraction efficiency, taking into account not only the selected
LÚA VÁZQUEZ FERREIRO 238 factors but also their interactions, reaching optimal conditions for all analytes. ANOVA was confirmed as a powerful statistical parameter, since it was applied for optimization, but also for the interpretation of the results. Multiple-range LSD tests were also applied with the aim of reaching the best extraction efficiency. Finally, PCA confirmed its suitability to describe differences between data set, for example to identify groups of honey from different botanical origins. Different degradation processes for the simultaneous removal of antibiotics were assessed. For this purpose, photolysis was tested using a laboratory-scale static photoreactor and, advanced oxidation processes were applied employing a tube-in-tube membrane reactor operating in continuous mode. Degradation efficiencies showed that both systems appeared to be good options for antibiotics removal in water. Analytical techniques based on chromatography coupled to mass spectrometry proved to be appropriate for the determination of the analytes of interest for which they were selected. Two types of chromatography, gas and liquid, were used for compound separations. Regarding the detection, instruments employed were based on two mass spectrometry approaches, using low-resolution and high-resolution instruments. For low resolution, mass spectrometry with a simple quadrupole was selected to determine volatiles and semi-volatiles in honey, obtaining good responses for the identification and quantification of the selected substances. Meanwhile, tandem mass spectrometry (triple quadrupole detector) coupled with gas chromatography was employed for the analysis of PCPs and fungicides and, coupled with liquid chromatography for phenolic compound analysis. This detector provides the unequivocal identification of the compounds as well as a high selectivity and sensitivity. Concerning the high resolution, two approaches were used with single and triple quadrupole time-of-flight detectors. It proved to be a powerful tool, especially for the identification of unknown compounds such as by-products generated during degradation processes, often at very low concentrations.
VI. Conclusions 245 Chapter 2. Characterization of honey: volatile, semi-volatile and phenolic compounds • A methodology based on miniaturized SPME followed by GC-MS has been proposed for the simultaneous analysis of different volatile and semi-volatile compounds in honey. • The extraction efficiency of twenty-four target compounds was assessed by DOE and they were investigated in twelve Galician honeys and eight foreign honeys. Nine of them were quantified, demonstrating the suitability of the proposed method. • A simple, fast and environmentally friendly procedure based on VE-UAE-LC-MS/MS was optimized to analyse phenolic compounds in 91 honeys from Galicia. • Statistical tools such as ANOVA and PCA revealed that phenolic compounds could be used as indicators to identify the honey floral origin since significant differences were obtained for TPC, AA and ∑phenolic compounds concentrations depending on the honey variety. Chapter 3. Determination of personal care products (PCPs) in cosmetic formulations • A new analytical methodology based on μMSPD-GC– MS/MS has been developed for the simultaneous analysis of multiclass organic UV filters and applied for other PCPs in cosmetic products, such as sunscreen, make up, and hair-care products, among others. • A protocol based on SPME-GC-MS/MS to determine PCPs, including fragrance allergens, synthetic musks, preservatives and plasticizers in hydroalcoholic gels was optimized. This high throughput and environmentally friendly
LÚA VÁZQUEZ FERREIRO 246 procedure was shown to be fast, simple and of easy implementation in any routine laboratory. • Some forbidden compounds for their use as ingredients in cosmetics according to the Regulation EC No 1223/2009 were found in cosmetic products. • Greater control over the formulations of the cosmetic products is necessary to ensure consumer safety without causing undesirable side effects. Chapter 4. Determination of antibiotics in water and degradation studies • A SPE method followed by two approaches based on UHPLC-HRMS was optimized and successfully validated for the simultaneous analysis of macrolides, cephalosporins, fluoroquinolones, sulfonamides and diaminopyrimidines in wastewater and natural waters. • A non-target screening based on a SWATHTM workflow was performed, demonstrating the presence of up to 94 compounds including pharmaceuticals, drugs and pesticides, among others. • Photodegradation appears as a good alternative to simultaneously remove the target antibiotics in ultrapure water. Twenty by-products could be identified by HRMS after UVC photolysis. • The operational conditions of a tube-in-tube membrane reactor, which is based on AOPs, have been optimized for the simultaneous degradation of the target antibiotics. • The low footprint tube-in-tube membrane reactor offers high antibiotic removal efficiencies under different treatments in demineralized water and urban wastewater.
ANNEX I: LIST OF PUBLICATIONS
Annex I: List of publications 251 • Maria Celeiro, Lua Vazquez, Piyaluk Nurerk, Abuzar Kabir, Kenneth G. Furton, Thierry Dagnac, Maria Llompart. Fabric phase sorptive extraction for the determination of 17 multiclass fungicides in environmental water by gas chromatography-tandem mass spectrometry, Journal of Separation Science, 43 (2020), 1817–1829 DOI: 10.1002/jssc.201901232 Impact factor: JCR: 3.645. CiteScore: 5.5. SJR: 0.72 (2020) JCR-Q2: Analytical Chemistry. CiteScore, SJR-Q2: Analytical Chemistry; Filtration and Separation Contribution: Formal analysis, Validation, Investigation, Data curation. • Maria Celeiro, Lua Vazquez, Meruyert Sergazina, Santiago Docampo, Thierry Dagnac, Vitor J.P. Vilar, Maria Llompart. Turning cork by-products into smart and green materials for solidphase extraction - gas chromatography tandem mass spectrometry analysis of fungicides in water, Journal of Chromatography A, 1628 (2020), 461437 DOI: 10.1016/j.chroma.2020.461437 Impact factor: JCR: 4.759. CiteScore: 6.9. SJR: 1.011 (2020) JCR-Q1: Analytical Chemistry; Biochemical, Research methods. CiteScore-Q1: Organic Chemistry; Analytical Chemistry; Biochemistry. SJR: Analytical Chemistry; Medicine (miscellaneous); Organic Chemistry (2020) Contribution: Formal analysis, Validation, Investigation.
LÚA VÁZQUEZ FERREIRO 252 • Meruyert Sergazina, Lua Vazquez, Maria Llompart, Thierry Dagnac. Occurrence of fungicides in vineyard and the surrounding environment, Molecules, 26(20) (2021), 6152 DOI: 10.3390/molecules26206152 Impact factor: JCR: 4.412. CiteScore: 4.7 (2020). SJR: 0.705 (2021) JCR-Q2: Chemistry, Multidisciplinary; Biochemistry & Molecular Biology. CiteScore-Q2: Chemistry (miscellaneous); Pharmaceutical Science; Physical and Theoretical Chemistry; Organic Chemistry; Analytical Chemistry; Drug Discovery (2020); SJR-Q1: Pharmaceutical Science (2021) Contribution: Methodology, Validation, Formal analysis, Investigation, Data curation, Writing-original draft preparation. • Lua Vazquez, Maria Celeiro, Meruyert Sergazina, Thierry Dagnac, Maria Llompart. Optimization of a miniaturized solid-phase microextraction method followed by gas chromatography mass spectrometry for the determination of twenty four volatile and semivolatile compounds in honey from Galicia (NW Spain) and foreign countries, Sustainable Chemistry and Pharmacy, 21 (2021), 100451 DOI: 10.1016/j.scp.2021.100451 Impact factor: JCR: 4.508. CiteScore: 4.5 (2020). SJR: 0.681 (2021) JCR-Q2: Environmental science; Chemistry, Multidisciplinary. CiteScore-Q1: Management, Monitoring, Policy and Law (2020). SJR-Q2: Environmental Chemistry; Management, Monitoring, Policy and Law; Pharmaceutical Science; Pollution (2021). Contribution: Formal analysis, Validation, Investigation, Data curation, Software, Writing - original draft, Writing - review & editing.
Annex I: List of publications 253 • Lua Vazquez, Daniel Armada, Maria Celeiro, Thierry Dagnac, Maria Llompart. Evaluating the presence and contents of phytochemicals in honey samples: phenolic compounds as indicators to identify their botanical origin, Foods, 10(11) (2021), 2616 DOI: 10.3390/foods10112616 Impact factor: JCR: 4.350; CiteScore: 3.0 (2020); SJR: 0.726 (2021) JCR-Q2: Food Science & Technology; CiteScore-Q1: Health Professions (miscellaneous) (2020); SJR-Q1: Food Science & Technology, Health Professions (miscellaneous), Health (social science) and Plant Science (2021). Contribution: Methodology, Validation, Formal analysis, Investigation, Data curation, Writing-original draft preparation. • Maria Celeiro, Lua Vazquez, J. Pablo Lamas, Marlene Vila, Carmen Garcia-Jares, Maria Llompart. Miniaturized matrix solidphase dispersion for the analysis of ultraviolet filters and other cosmetic ingredients in personal care products, Separations, 6(2) (2019), 30 DOI: 10.3390/separations6020030 Impact factor: JCR: 1.900. CiteScore: 2.4. SJR: 0.485 (2019) JCR, CiteScore, SJR-Q3: Analytical Chemistry (2019) Contribution: Validation, Formal analysis.
LÚA VÁZQUEZ FERREIRO 254 • Lua Vazquez, Maria Celeiro, Ana Castiñeira-Landeira, Thierry Dagnac, Maria Llompart. Development of a solid phase microextraction gas chromatography tandem mass spectrometry methodology for the analysis of sixty personal care products in hydroalcoholic gels ˗ hand sanitizers ˗ in the context of COVID-19 pandemic, Analytica Chimica Acta, 1203 (2022), 339650 DOI: 10.1016/j.aca.2022.339650 Impact factor: JCR: 6.558. CiteScore: 9.3 (2020). SJR: 1.105 (2021) JCR-Q1: Analytical Chemistry. CiteScore-Q1: Spectroscopy; Analytical Chemistry; Biochemistry; Environmental Chemistry (2020). SJR-Q1: Analytical Chemistry; Spectroscopy (2021) Contribution: Formal analysis, Validation, Data curation, Investigation, Writing – original draft, Writing – review & editing. • Lua Vazquez, Maria Llompart, Thierry Dagnac. Complementarity of two approaches based on the use of Quadrupole Time-of-Flight High-Resolution Mass Spectrometry for the determination of multiclass antibiotics in wastewater and natural waters. Photodegradation studies and non-targeted screenings, Environmental Science and Pollution Research. Under revision for publication Impact factor: JCR: 4.223. CiteScore: 5.5 (2020) SJR: 0.831 (2021) JCR-Q2: Environmental sciences. CiteScore-Q1: Pollution; Health, Toxicology and Mutagenesis (2020). SJR-Q1: Health, Toxicology and Mutagenesis (2021) Contribution: Validation, Formal analysis, Investigation, Data curation, Writing – original draft, Writing – review & editing.
Annex II. Journal permissions 261 • M. Sergazina, L. Vazquez, M., T. Dagnac. Occurrence of fungicides in vineyard and the surrounding environment, Molecules, 26(20) (2021), 6152 (Open Access) • L. Vazquez, D. Armada, M. Celeiro, T. Dagnac, M. Llompart. Evaluating the presence and contents of phytochemicals in honey samples: phenolic compounds as indicators to identify their botanical origin, Foods, 10(11) (2021), 2616 (Open Access) • M. Celeiro, L. Vazquez, J. P. Lamas, M. Vila, C. Garcia-Jares, M. Llompart. Miniaturized matrix solid-phase dispersion for the analysis of ultraviolet filters and other cosmetic ingredients in personal care products, Separations, 6(2) (2019), 30 (Open Access).
LÚA VÁZQUEZ FERREIRO 262 • L. Vazquez, M. Celeiro, A. Castiñeira-Landeira, T. Dagnac, M. Llompart. Development of a solid phase microextraction gas chromatography tandem mass spectrometry methodology for the analysis of sixty personal care products in hydroalcoholic gels ˗ hand sanitizers ˗ in the context of COVID-19 pandemic, Anal. Chim. Acta, 1203 (2022), 339650 (Open Access).
Annex II. Journal permissions 263 • L. Vazquez, M. Llompart, T. Dagnac. Complementarity of two approaches based on the use of Quadrupole Time-of-Flight High- Resolution Mass Spectrometry for the determination of multi-class antibiotics in wastewater and natural waters. Photodegradation studies and non-targeted screenings, Enviro. Sci. Pollut. R.
ANNEX III: INDEX OF FIGURES AND TABLES
Annex III: Index of figures and tables 267 FIGURES Introduction Figure 1. SPE procedure. 51 Figure 2. SPME extraction modes. 54 Figure 3. FPSE schematic procedure. 57 Figure 4. µMSPD schematic procedure. 61 Figure 5. Scheme of a triple quadrupole mass spectrometer working in SRM mode 70 Figure 6. QqToF spectrometer scheme. 73 Chapter 4.1. Figure 1. Recovery of the SPE procedure evaluating: a) the influence of sample pH (2, 3 and 5.5) and b) different types of cartridges. 151 Figure 2. Antibiotic recoveries obtained for real water matrixes fortified at 1 μg L −1 for well (WW), river (RW) and ultrapure (UP) water and at 5 μg L −1 for effluents from urban (EF5) and hospital (HW2) wastewater treatment plants: a) without considering isotopically labelled surrogates and b) considering isotopically labelled surrogates. 156 Figure 3. Detection frequency of target and non-target compounds in urban and hospital wastewaters. 160 Figure 4. Degradation kinetics observed for the 14 studied antibiotics under UVC irradiation. Initial concentration: 100 μg L−1. 161 Figure S1. Antibiotic recovery comparison between the manual and commercial cartridges for Oasis HLB and Strata X. 176 Figure S2. Study of the elution volume on SPE efficiency for the target compounds: a) Oasis HLB (60 mg, 3 mL); and b) Oasis HLB (200 mg, 6 mL), respectively. 177 Figure S3. Study of the sample breakthrough volume and its influence on SPE antibiotic recoveries. 178 Figure S4. Evaluation of matrix effect into the ionization source: a) comparison of standard solutions and spiked extracts after SPE; b) recovery values between the spiked extracts and the obtained extracts after SPE, using fortified ultrapure water. 179
Figure S5. Chromatographic peaks, isotopic profiles and MS/MS spectra of the photodegradation products: a) Azi-2; b) Clar-3; c) Ery-3 and d) Rox-2. 180 Chapter 4.2. Figure 1. Tube-in-tube reactor scheme. 197 Figure 2. Removal percentages for the 14 antibiotics after treatment with: a) UVC and UVC/oxidant; b) UVC and UVC/catalyst; c) UVC/catalyst/oxidant. 202 Figure 3. Removal percentages for the 14 antibiotics evaluating: a) UVC radiation and different doses of S2O82– employing the Ag2MoO4/S2O82- system; b) different sample pH for the UVC/Ag2MoO4/S2O82- treatment. 204 Figure 4. Flow rate assessment for the removal of the 14 antibiotics under the UVC/Ag2MoO4/S2O82- treatment. 205 Figure 5. Removal efficiency of the 14 antibiotics by UVC/Ag2MoO4/S2O82- treatment employing demineralized water (DW) or urban wastewater (UWW) under optimal conditions. 206 Figure 6. Assessment of the concentration of O3 in the annular reaction zone for the removal of the 14 antibiotics. 207 Figure 7. Removal efficiency of the 14 antibiotics under the ozonation process using demineralized water (DW) (Qinlet=150L/h or 50 L/h; [O3]ARZ= 6 mg/L or 18 mg/L) or urban wastewater (UW) (Qinlet=150L/h; [O3]ARZ= 6 mg/L). 208
Annex III: Index of figures and tables 269 TABLES Introduction Table 1. Fungicides name, CAS number, molecular weight (MW, g mol-1), chemical class, class hazard according to WHO [4] and chemical structure. 12,13 Table 2. Permitted MRLs for vine leaves, table grapes and wine grapes (mg kg-1) [16]. 16 Table 3. Volatile and semi-volatiles, CAS number, molecular weight (MW, g mol- 1) and chemical structure. 21,22 Table 4. Phenolic compounds, CAS number, molecular weight (MW, g mol-1) and chemical structure. 23-26 Table 5. Fragrance allergens, CAS number, molecular weight (MW, g mol-1) and chemical structure. 31,32 Table 6. Synthetic musks, CAS number, molecular weight (MW, g mol-1) and chemical structure. 33 Table 7. Preservatives and antioxidants, CAS number, molecular weight (MW, g mol-1) and chemical structure. 34,35 Table 8. UV filters, CAS number, molecular weight (MW, g mol-1) and chemical structure. 36,37 Table 9. Plasticizers, CAS number, molecular weight (MW, g mol-1) and chemical structure. 37-38 Table 10. Specific restrictions of the studied PCPs in cosmetic products according to Regulation 1223/2009 [39]. 40-41 Table 11. Families and antibiotics, CAS number, molecular weight (MW, g mol-1) and chemical structure. 43-44 Chapter 4.1. Table 1. Studied compounds. Acronym, CAS number, retention time, quantification and identification ions. 146 Table 2. Method performance. Linearity, precision, mean recoveries in ultrapure water, LODs and LOQs. 154 Table 3. Concentrations (μg L−1) of the target antibiotics in different water samples. EF: urban effluent; INF: urban influent; HW: hospital effluent; WW: well water; RW: river water. 158
LÚA VÁZQUEZ FERREIRO 270 Table 4. Data for the photodegradation products: parent compounds, photoproducts, molecular formulae, precursor ions, structures, mass errors, exposure times with maximum response and bibliographic references. 165-167 Table S1. Gradient elution program for the liquid chromatography separation. 176 Table S2. Non-target compounds identified in real water samples by QToF- HRMS. 181-188 Chapter 4.2. Table 1. Identified transformation products for O3 and UVC/Ag2MoO4/S2O82- treatments. 210-212
Annex IV: Resumo 277 Ademais, é importante sinalar que o método tamén é adecuado e aplicable para outro tipo de follas, como o té. Outras matrices, como uvas ou solos, tamén se analizaron mediante a metodoloxía baseada en UAE-GC-MS/MS. Por outro lado, a extracción asistida por microondas (MAE) revelou resultados similares aos obtidos por UAE para o estudo dos funxicidas de interese en solos. Non obstante, seleccionouse UAE co obxectivo de utilizar a menor cantidade de mostra e disolvente e minimizar os costos. Por outra banda, como os funxicidas adoitan estar presentes en niveis traza nas augas, o desenvolvemento de métodos analíticos sensibles para a extracción de ditos compostos nesta matriz presentan gran interese. Deste xeito, leváronse a cabo a optimización de dous enfoques para determinar funxicidas en augas. A SPE é a técnica máis empregada para extraer funxicidas en mostras acuosas debido á súa capacidade de extracción, o alto factor de enriquecemento e a súa simplicidade. Sen dúbida, o elemento máis crítico para obter unha técnica de SPE favorable é a selección do adsorbente, xa que xoga un papel moi importante para a eficacia e selectividade dos analitos de interese. Por esta razón, propúxose utilizar subprodutos de cortiza como adsorbente de SPE para a extracción dos 17 funxicidas obxectivo do estudo. A cortiza é un material heteroxéneo cunha composición química formada principalmente por biopolímeros hidrofóbicos e polisacáridos hidrófilos, que proporcionan sitios para a adsorción de compostos orgánicos. Ademais, pode ser tratado térmicamente para mellorar posibles interaccións con compostos orgánicos menos polares. Polo tanto, as principais vantaxes deste material eco-natural son que é un adsorbente alternativo renovable, biodegradable e de baixo costo que favorece a economía circular. En canto á FPSE, é unha novidosa técnica de preparación da mostra que presenta unha serie de vantaxes sobre técnicas convencionais, xa que combina o modo de extracción en equilibrio da microextracción en fase sólida (SPME) coa extracción exhaustiva da SPE nunha única plataforma.
LÚA VÁZQUEZ FERREIRO 278 Ambas técnicas de extracción empregadas para a análise de funxicidas en auga foron optimizadas mediante deseños de experimentos. O protocolo de SPE implica un deseño multifactorial, 23 con dous puntos centrais. Os factores avaliados foron o tipo de cortiza, o disolvente de extracción e o pH da mostra. Para o procedemento FPSE, realizouse un deseño de cribado de media fracción 25-1 máis dous puntos centrais, que deron lugar a 18 experimentos. Neste caso, os parámetros de estudo foron o volume de mostra, o disolvente de desorción, o tempo de desorción, a adición de NaCl e o pH da auga. En ambos casos, as metodoloxías foron validadas en termos de linearidade, precisión (repetibilidade e reproducibilidade), exactitude, límites de detección (LODs) e cuantificación (LOQs), mostrando resultados satisfactorios en todos os casos. Tamén se avaliaron os posibles efectos da matriz mediante estudos de recuperación realizados en diferentes matrices de auga. Aínda que un dos funxicidas diana (metalaxil) presentou problemas de recuperación nalgunhas das matrices de auga utilizando FPSE (por exemplo, a auga da billa), no caso de SPE os valores medios de recuperación de dito composto atopáronse ao redor do 30 % en todas as matrices, incluso en auga ultrapura. Deste xeito, o método baseado en FPSE-GC-MS/MS resultou ser máis eficiente para a extracción do metalaxil en auga, aínda que, ambos procedementos poden considerarse alternativas adecuadas para a determinación de niveis traza de funxicidas en mostras de auga. En consecuencia, son técnicas prometedoras para a extracción doutros compostos orgánicos que poden estar presentes no medio acuático. Finalmente, os tres protocolos aplicáronse a mostras reais demostrando a presenza de funxicidas en altas concentracións nos cultivos e no medio ambiente. Algunha das substancias obxectivo superaron os límites máximos de residuos (MRLs) establecidos pola Comisión Europea en follas de vide e en uvas, e a concentración máxima permitida para pesticidas en augas subterráneas e en augas destinadas ao consumo humano. Estes resultados revelaron que os modos de aplicación dos funxicidas sobre os cultivos deben mellorarse.
Annex IV: Resumo 279 2.- Capítulo 2. Caracterización do mel: compostos volátiles, semivolátiles e fenólicos O mel é un produto alimenticio natural coñecido polo seu alto valor nutricional, debido á presenza de azucre, proteínas, aminoácidos, enzimas, ácidos orgánicos, vitaminas, minerais, compostos fenólicos e volátiles. A orixe botánica e xeográfica do mel condiciona a súas propiedades. O seu perfil aromático configura as súas características organolépticas, a súa identidade e a súa calidade e, por outro lado, os compostos fenólicos presentes na mel demostraron a súa alta capacidade antimicrobiana e antioxidante. Unha alta proporción do mel producido en Galicia está recoñecido baixo a denominación de Identificación Xeográfica Protexida (IXP), polo que é importante identificar posibles marcadores químicos nestes meles. Ademais, dependendo da zona na que se produza o mel, terá unha orixe botánica diferente, polo que tamén é de gran interese poder diferencialo segundo a orixe floral do néctar extraído polas abellas. O mel é unha matriz complexa que precisa dun paso de preparación da mostra previo á súa análise. As técnicas de preparación da mostra implicadas para a análise do mel nesta tese son a SPME para a determinación de compostos volátiles e semivolátiles por GC-MS, e unha combinación de VE seguida de UAE para avaliar a presenza de compostos fenólicos por cromatografía líquida seguida de espectrometría de masas en tándem (LC-MS/MS). Por outro lado, leváronse a cabo protocolos para o estudo do contido fenólico total (TPC) e a actividade antioxidante (AA) empregando un espectrofotómetro ultravioleta-visible (UV-Vis). A SPME é unha das técnicas preferidas para a extracción de volátiles e semivolátiles no mel. Non obstante, co obxectivo de reducir o costo, a cantidade de mostra e os residuos xerados, a miniaturización da SPME (mini_SPME), que permite utilizar unha cantidade moi pequena de mel (200 mg), pareceu ser unha boa opción, xa que as respostas cromatográficas resultaron ser bastante similares que cando se usa 10 veces máis de cantidade de mel (2 g). Empregouse un deseño experimental factorial de nivel mixto (3·23-1 + 2 puntos centrais) para avaliar catro parámetros críticos que poden afectar á eficacia da
LÚA VÁZQUEZ FERREIRO 280 mini_SPME, para a determinación de 24 substancias previamente seleccionadas: temperatura, recubrimento da fibra, adición de NaCl e dilución. O método validouse satisfactoriamente, logrando boa linearidade, precisión, LODs e LOQs, e estudáronse recuperacións en catro tipos diferentes de mel. Finalmente, o método aplicouse para la identificación dos 24 compostos e a cuantificación de 9 deles nunha ampla gama de variedades galegas e estranxeiras (Francia, Grecia, Italia e Kazajstán). Non obstante, sería necesaria unha aproximación estatística adicional para comprobar se os compostos se poden considerar como marcadores dos meles galegos. Por outra banda, para a investigación de compostos fenólicos no mel, utilizouse unha metodoloxía moi simple que combina VE con UAE, utilizado disolventes de base acuosa. Dado que o manexo do mel é bastante complexo, normalmente para o estudo de substancias fenólicas emprégase SPE para eliminar compoñentes da matriz que poden interferir na análise, como os azucres. Non obstante, nesta investigación, tras unha previa optimización, demostrouse que a calibración externa era adecuada para poder cuantificar 41 compostos fenólicos aplicando unha estratexia bastante máis rápida e sinxela. Nas mostras reais analizadas puidéronse identificar e cuantificar 25 dos 41 analitos obxectivo. Ademais, para a avaliación do TPC e da AA utilizáronse adaptacións de protocolos previamente propostos na bibliografía. Para a interpretación dos resultados, fíxose un estudo quimiométrico facendo uso de distintas ferramentas estatísticas, como ANOVA e análise de compoñentes principais (PCA) para obter modelos que permitiran clasificar 91 meles galegos diferentes, segundo a súa orixe botánica. Entre estes meles atopáronse meles de tipo multifloral, melada, breixo, castiñeiro, castiñeiro/melada, silva e eucalipto. Estes estudos baseáronse no TPC, AA e na concentración fenólica individual e/ou a concentración total destas substancias, mostrando diferenzas significativas de acordo coa variedade de mel. 3.- Capítulo 3. Determinación de produtos de coidado persoal (PCPs) en formulacións cosméticas
Annex IV: Resumo 281 Os cosméticos, como as cremas faciais e corporais, a maquillaxe, os produtos para o coidado do cabelo, entre outros, son produtos de amplo consumo en todo o mundo. Hoxe en día un dos produtos cosméticos máis utilizados son os xeles hidroalcólicos, xa que se empregan con moita frecuencia varias veces ao día ao volverse esenciais para a prevención do contaxio por SARS-CoV-2 e evitar a súa propagación, especialmente en forma de Covid-19. Nas formulacións cosméticas están atópanse gran número de compostos orgánicos, como por exemplo as fragrancias alerxénicas, conservantes, plastificantes, almiscres sintéticos, filtros ultravioleta (UV), entre outros. As fragrancias (alérxenos e almiscres sintéticos), que adoitan engadirse aos cosméticos coa intención de proporcionar un aroma agradable, son as principais responsables da dermatite alérxica de contacto. Os filtros UV están destinados a protexer aos consumidores contra a radiación solar e a súa presenza é especialmente importante nos protectores solares, pero tamén poden encontrarse nunha ampla gama de produtos de coidado diario. Os conservantes engádense ás fórmulas cosméticas para protexer os produtos e aos consumidores contra o crecemento microbiano, mentres que os plastificantes ademais de ser engadidos, poden pasar dos envases de plástico ao propio produto. A presencia de moitas destas substancias en cosmética, asóciase a alerxias de contacto, dermatite cutánea e incluso, nalgún caso, a efectos canceríxenos e disfuncións endócrinas. Os produtos cosméticos comercializados na Unión Europea deben seguir a lexislación vixente, polo tanto, deben cumprir co Regulamento CE nº 1223/2009, e dito cumprimento debe ser verificable analiticamente. Neste contexto, a análise de cosméticos é unha tarefa difícil debido á gran variedade e complexidade das mostras, compostas por un elevado número de substancias de diferente natureza. Desenvolvéronse dúas metodoloxías analíticas utilizando µMSPD e SPME, para determinar un alto número de PCPs en diferentes cosméticos. En ambos casos, os PCPs analizáronse por GC debido á natureza química dos analitos obxectivo. En canto á detección, elixiuse a espectrometría de masas en tandem para mellorar a selectividade e sensibilidade analítica.
LÚA VÁZQUEZ FERREIRO 282 Optimizouse un método baseado en µMSPD para as análises de 14 filtros UV, tratándose dunha aproximación moi novedosa xa que nunca se aplicara dita técnica para a extracción destas substancias en formulacións cosméticas. Os factores que afectan ao proceso, como o axente dispersante e a cantidade e o tipo de disolvente de elución, estudáronse mediante un deseño de experimentos. Neste caso seleccionouse un deseño multifactorial 4·22, que incluía 16 experimentos aleatorios. Unha vez optimizado o método, avaliouse o rendemento da metodoloxía µMSPD-GC-MS/MS e estendeuse a outros PCPs, como alérxenos, almiscres sintéticos, conservantes e plastificantes, dando un total de 78 PCPs. O método presentou unha boa linearidade e precisión e, a maiores, despois de realizar estudos de recuperación fortificando unha crema de mans hidratante, obtivéronse rendementos entre o 70 e o 110 % para todos os compostos. O protocolo establecido permitiu a análise simultánea nunha soa extracción dun total de 78 compostos con natureza química moi diferente nunha ampla variedade de produtos cosméticos (protectores solares, cremas, maquillaxe, barras de beizos...). En canto á análise de xeles hidroalcólicos empregouse a SPME que, ata o método desenvolvido nesta tese nunca se aplicara para a extracción simultánea multianalitos de PCPs en mostras cosméticas. Neste caso, incluíronse un total de 60 substancias, abarcando fragrancias alerxénicas, almiscres sintéticos, conservantes e plastificantes. Para a optimización deste protocolo realizouse un deseño categórico multifactorial (3·22) no que se avaliaron os principais factores e as súas interaccións. Os parámetros incluídos en dito deseño foron o recubrimento da fibra, o modo de extracción e a temperatura. En condicións optimizadas, o método SPME-GC-MS/MS foi validado en termos de linearidade, precisión e exactitude, obtendo bos resultados e seguindo na medida do posible a norma internacional ISO12787 "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques". Posteriormente, o método aplicouse a mostras reais de xeles hidroalcólicos para comprobar o cumprimento da lexislación aplicable (Regulamento CE nº 1223/2009), así como as recomendacións da Organización Mundial da Saúde (OMS)
Annex IV: Resumo 283 de homoxeneizar a formulación e fabricación dos xeles hidroalcólicos, asegurando as súas propiedades antimicrobianas. Así, ambas metodoloxías resultaron ser sinxelas, adecuadas, verdes e rápidas para determinar un elevado número de PCPs en produtos cosméticos de distinta natureza. En ambos casos, non se necesitou calibración en matriz, o que simplifica aínda máis os procedementos e facilita o seu uso en calquera laboratorio de rutina. Demostrouse a presenza de compostos prohibidos segundo o Regulamento CE nº 1223/2009, en diferentes produtos cosméticos, así como de fragrancias alerxénicas en concentracións superiores a 10 μg g-1, que é o límite establecido a partir do cal debe constar a súa presenza na etiqueta en xeles hidroalcólicos. Ademais, ningunha das formulacións das mostras analizadas de xeles hidroalcólicos cumpriu as recomendacións da OMS. Polo tanto, os resultados obtidos revelaron a necesidade dun maior control sobre os produtos cosméticos para garantir a seguridade do consumidor sen causar efectos secundarios indesexables. 4.- Capítulo 4. Determinación de antibióticos en auga e estudos de degradación Debido ao crecente uso de produtos farmacéuticos tanto por parte da poboación como en actividade veterinaria, a súa presenza e persistencia na auga é cada vez maior. Entre estes compostos, un dos grupos que presenta máis interese son os antibióticos, que poden causar resistencia microbiana debido a un uso irresponsable e irracional. Como soamente son parcialmente eliminados nas plantas de tratamento de augas residuais, estas substancias entran continuamente no medio ambiente, o que supón un risco importante non só para o ecosistema acuático, se non tamén para a saúde humana. Deste xeito, procedementos alternativos como os procesos de fotodegradación e oxidación avanzada parecen ofrecer unha boa opción para a eliminación eficiente de antibióticos e doutros contaminantes emerxentes. Empregouse a SPE para o illamento de 14 antibióticos en augas residuais e naturais, incluíndo macrólidos, cefalosporinas, fluoroquinolonas, sulfonamidas e diaminopirimidinas. A análise
LÚA VÁZQUEZ FERREIRO 284 levouse a cabo mediante dous enfoques baseados na espectrometría de masas de alta resolución (HRMS), utilizando un detector de tempo de voo de cuadrupolo simple e un de triple cuadrupolo. O método de extracción optimizouse empregando diferentes parámetros como o pH da mostra, a cantidade de mostra e disolvente, e o cartucho SPE, entre outros. Neste caso, o cartucho SPE foi un adsorbente hidrofílico-lipófilico convencional, coñecido co nome comercial de Oasis HLB (casa comercial Waters). Posteriormente, a metodoloxía validouse logrando boa linearidade, precisión, LODs e LOQs. Por outro lado, os valores de recuperación obtidos en auga ultrapura foron satisfactorios, estando por encima do 80 % excepto para dous compostos (os macrólidos azitromicina e eritromicina). Polo tanto, estudouse se estes baixos valores eran debidos a unha baixa eficiencia de extracción ou a efectos matriz xerados na fonte de ionización do espectrómetro de masas. Para isto, comparáronse extractos enriquecidos antes e despois do proceso de SPE, mostrando que non existía supresión de ionización da fonte, e que a escasa capacidade de retención do adsorbente era a responsable das baixas recuperacións. Ademais, leváronse a cabo estudos de recuperación en catro matrices reais diferentes, observando que o tipo de matriz de auga si que influíu no rendemento da extracción. Para as matrices máis complexas (augas residuais urbanas e hospitalarias) as porcentaxes de recuperación diminuían considerablemente, polo que era necesario o uso de compostos marcados isotopicamente. Unha vez validado o método, cuantificáronse os antibióticos diana en augas residuais e naturais. Para analizar os antibióticos diana, utilizouse un espectrómetro de masas de cromatografía líquida de ultra alta eficacia acoprado a un cuadrupolo-tempo de voo (UHPLC-QToF). Pola contra, empregouse outra configuración de espectrometría de masas de alta resolución para un estudio non obxectivo, usando un instrumento SCIEX TripleTOF (QqQTof) en modo SWATHTM (adquisición secuencial por ventás de todos os espectros de masas teóricos). O fluxo de traballo SWATH basease na selección dun rango de m/z no que se inclúen todos os analitos, logo o rango divídese en numerosas ventás de m/z (normalmente entre 20 e 30) e rexístranse os espectros MS/MS para
Annex IV: Resumo 285 todos os picos detectados. Deste xeito, dado que se obtén de forma simultánea un barrido completo da mostra e os espectros MS/MS para todos os picos, non é necesario introducir nin masas precursoras nin transicións de masas. Unha das potentes características que permite este modo de escaneamento é a posibilidade de realizar buscas retrospectivas sen obxectivo utilizando o mesmo arquivo bruto de adquisición de datos. Este enfoque permitiu identificar ata 94 compostos non diana, entre os cales se atoparon outros antibióticos, drogas, fármacos, pesticidas, etc..., tendo en conta as masas exactas dos compostos descoñecidos e outros criterios adicionais para a confirmación, como o perfil isotópico e a puntuación de librería calculada cos espectros MS/MS de alta resolución, proporcionando unha puntuación final combinada. A presenza dos antibióticos en mostras reais indicou a facilidade coa que poden alcanzar o medio acuático. Polo tanto, o uso e a mellora dos procedementos de purificación da auga é de gran interese para protexer o medio ambiente. Para iso, realizouse un estudo preliminar no que se abordou a fotólise UVC simultánea dos 14 antibióticos diana empregando un reactor estático a escala de laboratorio. É importante destacar que, aínda que estas substancias están presentes como una mestura no medio ambiente, poucos estudos avalían a degradación simultánea dun número tan elevado de antibióticos multiclase. Os resultados obtidos mostraron que a fotodegradación parecía ser unha opción útil para a eliminación da maioría dos antibióticos diana en auga ultrapura. Non obstante, é necesario realizar estudos adicionais noutras matrices de augas reais. Deste xeito, testáronse procesos de oxidación avanzada (AOPs) caracterizados pola xeración de especies oxidantes altamente reactivas. Para iso, optimizáronse as condición operacionais dun reactor de membrana tubo en tubo, traballando en modo continuo. Avaliáronse tanto oxidantes líquidos (H2O2, S2O82-) como gasosos (O3), destacando que foi a primeira vez que neste tipo de reactor se utilizou un oxidante gasoso. Tamén se estudiaron distintos catalizadores (Ag2MoO4 e TiO2), o uso de radiación UVC e o caudal de mostra. Estes tratamentos resultaron ser unha alternativa prometedora para a eliminación de
LÚA VÁZQUEZ FERREIRO 286 compostos en augas residuais urbanas, especialmente o baseado na ozonización. Por outro lado, durante a degradación poden formarse subprodutos, polo que a súa identificación tamén é de gran importancia. Nesta tese, levouse a cabo unha identificación destes subprodutos mediante a implantación dunha adquisición SWATH, podendo encontrar e identificar ata 20 produtos de transformación baixo a fotólise UVC.