scieee AI-readable full text Open interactive document viewer

Photophysical study of Thioflavin T as fluorescence marker of amyloid fibrils

Freire Rodríguez, Sonia; Araujo, Marcus H. de; Al-Soufi, Wajih; Novo, Mercedes

Abstract

Thioflavin T is a highly sensitive fluorescent marker of amyloid fibrils that has been widely used for in vitro biomedical assays. However, neither its complex photophysical behavior nor its binding mode to amyloid fibrils are still well understood. We present a detailed analysis of the photophysical properties of Thioflavin T in various media, including solvents and solvent mixtures of different viscosities as well as fibrillar and globular proteins. We propose a model that explains the strong wavelength dependency of the Thioflavin T fluorescence and the large fluorescence enhancement in certain environments. We determine the binding affinities and the fluorescence properties of Thioflavin T bound to amyloid-β (1–42) fibrils and to bovine serum albumin and discuss the sensitivity and the specificity of this probe to amyloid aggregates. These results allow us to assess the suitability of Thioflavin T for quantitative determinations in biomedical studies

Full text

1 Photophysical study of Thioflavin T as fluorescence marker of amyloid fibrils Sonia Freire, Marcus H. de Araujo, Wajih Al-Soufi and Mercedes Novo* Departamento de Química Física, Facultade de Ciencias, Universidade de Santiago de Compostela, E-27002 Lugo (Spain), Tel. (+34) 982824084, Fax: (+34) 982824001, E-mail: [email protected] Abstract Thioflavin T is a highly sensitive fluorescent marker of amyloid fibrils that has been widely used for in vitro biomedical assays. However, neither its complex photophysical behavior nor its binding mode to amyloid fibrils are still well understood. We present a detailed analysis of the photophysical properties of Thioflavin T in various media, including solvents and solvent mixtures of different viscosities as well as fibrillar and globular proteins. We propose a model that explains the strong wavelength dependency of the Thioflavin T fluorescence and the large fluorescence enhancement in certain environments. We determine the binding affinities and the fluorescence properties of Thioflavin T bound to amyloid-β (1-42) fibrils and to bovine serum albumin and discuss the sensitivity and the specificity of this probe to amyloid aggregates. These results allow us to assess the suitability of Thioflavin T for quantitative determinations in biomedical studies. Keywords Thioflavin T, amyloid fibril, fluorescent marker, photophysical properties, molecular rotor Abbreviations Aβ40 – Amyloid-β (1-40), with 40 aminoacids Aβ42 – Amyloid-β (1-42), with 42 aminoacids BSA – Bovine serum albumin Buffer sol. – Buffer solution (PBS buffer of pH 7.2) CT – Charge transfer This is the accepted manuscript of the following article: Freire, S., de Araujo, M., Al-Soufi, W., & Novo, M. (2014). Photophysical study of Thioflavin T as fluorescence marker of amyloid fibrils. Dyes And Pigments, 110, 97-105. doi: 10.1016/j.dyepig.2014.05.004. © 2014 Elsevier B.V. This manuscript version is made available under the CC-BY-NC-ND 4.0 license (http://creativecommons.org/licenses/by-nc- nd/4.0/) 2 DMSO – Dimethyl sulfoxide GA – Global Analysis HAS – Human serum albumin HFIP – Hexafluoroisopropanol LE – Locally excited state PBS – Phosphate buffered saline PCA – Principal Components Analysis PCGA – Principal Components Global Analysis ThT – Thioflavin T TICT – Twisted intramolecular charge-transfer 3 1. Introduction The term amyloidosis refers to a group of diseases caused by misfolded proteins that accumulate in various tissues and organs leading to disruption of their normal function. These proteins form insoluble aggregates, called amyloid fibrils, which are characterized by a fibrillar morphology, β-sheet-rich structure and green birefringence upon staining with Congo Red [1]. The most common marker used for the detection of amyloid fibrils is Thioflavin T (ThT), a fluorescent dye of the benzothiazole family that shows a huge fluorescence enhancement upon binding to amyloid aggregates [2,3]. This dye can be used both for visualization and quantification of amyloid fibrils in vitro using fluorescence spectroscopy and for amyloid diagnosis in tissue sections using fluorescence microscopy [2]. ThT has also been used to monitor the fibrillation process [4,5], although recent studies suggest that the dye itself may promote amyloid aggregation [6]. Another disadvantage of ThT is its lack of interaction with amyloid oligomers and protofibrils [7], which have been proposed to be responsible for neurotoxicity rather than fibrils [8-10]. Scheme 1. Molecular structure of Thioflavin T with the torsion angle φ between the benzothiazole and the aminobenzene moieties. The photophysical mechanism underlying the dramatic fluorescence enhancement of ThT upon binding to amyloid fibrils has been widely studied but is still controversial. Numerous studies postulate that ThT behaves as a molecular rotor, so that its fluorescence properties are determined by the extent of quenching of the locally excited (LE) state to a dark twisted intramolecular charge-transfer (TICT) state [3]. This quenching implies the twisting around the central C―C 4 single bond (torsion angle φ) in the excited state [11], and is therefore highly dependent on the viscosity of the medium. The observed fluorescence enhancement of ThT in viscous solvents and in different confined environments, where the twisting process is hindered, support this hypothesis, as well as the low fluorescence quantum yields of this dye in non-viscous solvents [12-19]. Also the excited-state dynamics from LE to TICT state have been recently found to be correlated with the viscosity of the medium [20]. Notwithstanding this well founded hypothesis, in the last few years some reports have attributed the changes of ThT fluorescence upon binding to amyloid fibrils to the formation of highly fluorescent dimers, excimers or even micelles of ThT molecules [2,21]. Excimer formation is very unlikely since the lifetime of ThT bound to amyloid fibrils is too short. Also the formation of micelles by ThT is very doubtful and is not clearly supported by the published conductivity data [22]. Hence, in our opinion, the only plausible alternative hypothesis proposed so far would be that ThT binds to amyloid fibrils as dimers. However, dimers of ThT have still not been experimentally detected [23]. The binding mode of ThT to amyloid fibrils has been extensively studied in order to achieve a better structural understanding of amyloid fibrils as well as to explore the potential therapeutic use of this dye. Nevertheless, to date there is no conclusive model that accounts for the orientation and conformation of ThT when bound to amyloid fibrils [2]. Confocal microscopy studies suggested that ThT binds as monomer to amyloid fibrils such that their long axes are parallel [24]. On the basis of crystal structures contradictory results have been reported [25,26], but they are compatible with the existence of a binding region of ThT at the amyloid fibril surface [21]. Very recently the results obtained by Polarization-Resolved Fluorescence Microscopy using ThT as marker revealed polymorphism of insulin amyloid fibrils [27]. Among the many different amyloid-like peptides, those called amyloid-β were given most attention due to their primal role in the development of Alzheimer`s disease as they accumulate as insoluble plaques among the neurons at the brain [28]. These deposits are formed mainly by 5 peptides of 40 aminoacids (Aβ40) and 42 aminoacids (Aβ42), the latter being at a higher proportion [28-30]. The Aβ42 shows a higher hydrophobicity and a much lower critical concentration for aggregation than Aβ40, so that it aggregates very fast and has a high tendency to form fibrils [10,31,32]. In spite of its arduous handling, we have used Aβ42 in this work due to its greater relevance in amyloid aggregation. 2. Material and method 2.1 Materials Thioflavin T (ThT, Fluka) was used without further purification. Bovine serum albumin (BSA) was purchased from Sigma-Aldrich and human amyloid-β (1-42) (Aβ42) from GenScript USA Inc. Phosphate buffered saline (PBS, pH = 7.2, 150 mM NaCl) was used for the preparation of the amyloid-β samples. The solvents used, chloroform (Sigma-Aldrich) and glycerol (Panreac), had a purity of 99%. All aqueous solutions were prepared using Milli-Q water. 2.2 Sample Preparation Stock solutions of ThT in the different solvents or solvent mixtures were prepared by weighing. The real dye concentration was determined experimentally from the absorbance in water using the reported value of 36,000 M-1 cm-1 for the molar extinction coefficient of ThT in water at 412 nm [2]. These stock solutions were used within a few days and diluted to the adequate concentration in each experiment. The measurements showed in this work were performed at the following ThT concentrations: (a) PBS samples: 1.2 and 9.4 µM; (b) chloroform samples: 1-2 µM; (c) Glycerol-water mixtures: 2.2 µM; (d) samples with Aβ42 fibrils: 1.1 and 7.0 µM for fluorescence and 244 µM for absorption measurements; (e) samples with BSA: 2.4 and 3.1 µM for fluorescence and 12.2 µM for absorption and lifetime measurements. Stock solutions of BSA and fibrillar Aβ42 were freshly prepared for each experiment. The samples for the titrations were prepared by the dilution-extraction method beginning with the corresponding protein stock solution containing the desired concentration of ThT and diluting 6 with a solution of ThT of the same concentration. Amyloid concentrations mentioned in this work refer to the total concentration of amyloid monomers used in the preparation of the sample. For the preparation of amyloid-β fibrils we followed established protocols [33]. Firstly, potential aggregates that could be formed in the commercial peptide were broken up by hexafluoroisopropanol (HFIP). The amyloid was dissolved in HFIP at a concentration of 1 mg/ml and the solution was incubated during 1 hour with occasional mixing and then shaken for about 20 minutes. Next the solution was split up into several vials and the HFIP was removed under a stream of nitrogen. Vials were transferred into a desiccator and vacuum was applied to remove the remaining traces of HFIP. The resulting dried aliquots of monomeric peptide were stored at - 20 ºC. Stock solutions of the amyloid were prepared by suspending the peptide aliquot in dried dimethyl sulfoxide (DMSO) with a final concentration of ≈1 mM and shaking it for about 15 minutes in order to dissolve the peptide. To prepare β-amyloid fibrils an aliquot of the DMSO stock solution was dissolved in PBS at pH 7.2. This sample was incubated at 37 ºC for 2 days under vigorous agitation. 2.3 Absorption and Fluorescence Measurements Absorption spectra were recorded using quartz cells with path lengths of 3.00 and 10.0 mm in a Varian-Cary 100 spectrometer. All spectra were recorded using baseline correction with the corresponding solvent. Nevertheless, for the titrations with BSA and Aβ42, further correction of the experimental absorption spectra was required in order to subtract the contributions of protein absorption and light dispersion (only for the samples with Aβ42). The absorption spectra are given in units of molar absorptivity. Steady-state and time-resolved fluorescence measurements were performed using an Edinburgh- Instruments F900 spectrofluorimeter, equipped with a Xenon lamp of 450 W as excitation source for steady-state measurements and a picosecond diode laser 405-nm laser (Becker & Hickl 7 GmbH, ≈80 ps, 20 MHz) for lifetime measurements with the time-correlated single photon counting technique. Excitation and emission fluorescence spectra were corrected for the wavelength-dependent output of the Xenon lamp and the non-ideal response of the instrument, respectively. Additionally, all spectra were corrected for the solvent contribution, in order to remove the intense Raman bands appearing in the samples of very low quantum yields and the fluorescence of impurities in the samples with glycerol. The contribution of BSA and Aβ42 autofluorescence was also subtracted. Fluorescence quantum yields were determined using Quinine Sulphate ( φ = 0.58 in 0.1 M sulfuric acid) [34] or Coumarin 152 ( φ = 0.064) [35] as standards for excitation wavelengths below and above 400 nm, respectively. For anisotropy measurements Glan-Thompson polarizers were used with a spectral range of 230-900 nm. Both absorption and fluorescence measurements were carried out at 25 ± 1 ºC. 2.4 Data analysis Most data processing was done with the program OriginPro 8.5 (OriginLab Corporation, US). The series of absorption and emission spectra obtained in the titrations were analyzed using a program developed in our group which applies Principal Components Global Analysis (PCGA) [36]. The first step of PCGA is the Principal Components Analysis (PCA) which yields the minimal number of components that reproduce the experimental spectra, i.e. it allows one to determine the number of chemical species that contribute to the spectra. This step helps to propose a mechanism which explains the observed variations. Global Analysis (GA) consists in the fit of the proposed theoretical model to the whole series of experimental spectra in order to estimate the model parameters and the pure spectra of the contributing species. Individual fits of fluorescence decays were performed with the software package from Edinburgh Instruments. The series of fluorescence decays measured at different protein concentrations together with the corresponding pulse responses were also fitted globally using a home-made program in Matlab (The MathWorks, US). 8 The values of refractive index and viscosity of the solvents and glycerol-water mixtures were obtained from the literature [37-39]. Different properties Y (absorbance, fluorescence intensity, ...) were related to protein concentration [H] by a 1:1 complexation model with binding equilibrium constant K and the limiting values of the property for free and bound dye, A and B, respectively: · ·[H] 1 [H] A BK YK + =+ (1) 3. Results and discussion The photophysical behavior of ThT is very complex, already in aqueous solution, but even more in the presence of BSA or Aβ42-fibrils. In order to understand it the full picture has to be analyzed, comparing and explaining critically the results from multiple techniques in different solvents and environments. In the following the absorption, steady-state fluorescence emission, excitation and anisotropy spectra are analyzed in different media as function of excitation and emission wavelength, concentrations of BSA and Aβ42-fibrils as hosts and the solvent viscosity in glycerol water mixtures. A model is described which gives a good explanation of the experimental findings and which is in line with results published by other authors. 3.1 Wavelength dependency of ThT fluorescence and absorption Figure 1 shows fluorescence emission spectra measured at different excitation wavelengths, together with excitation spectra monitored at two emission wavelengths and the absorption spectra, of ThT in three environments: aqueous solution, chloroform and a concentrated solution of amyloid fibrils. Chloroform was chosen as an aprotic and relatively nonpolar solvent, opposite to water. Fluorescence emission maxima, quantum yields and anisotropy determined for each excitation wavelength are given in Table 1. 9 Figure 1. Absorption (light gray solid lines) and fluorescence excitation (dark gray lines on the left) and emission (black lines on the right) spectra of ThT in PBS buffer, chloroform and in the presence of an aqueous solution of Aβ42 138 µM. Excitation spectra monitored at 440-nm (grey dashed lines) and 480-nm (grey dotted lines). Emission spectra measured with excitation at 350 nm (black solid lines), 375 nm (black dashed lines), 410 nm (black dotted lines) and 430 nm (black dash-dot-dashed lines). Fluorescence intensity (left scale) was measured under the same experimental conditions for all three samples. Absorption spectra are given in units of molar absorptivity (right scale). Some spectra were multiplied by factors as indicated. 16 The absorption spectrum in this medium corresponds to the wide distribution of conformers of both free and bound ThT, weighted by concentration and absorptivities. Only a small fraction of ThT is in a conformation with torsion angles low enough to lead to absorption at higher wavelengths. However, the excitation spectrum is additionally weighted by the quantum yield, which is especially high for low torsion angles. Therefore, the excitation spectra recorded at higher emission wavelengths selectively represent those highly emissive conformations, not distinguishable in the absorption spectrum due to their low contribution. From this notably complex photophysical behavior it can already be concluded that ThT is not a suitable probe for the quantitative determination of amyloid fibrils. All fluorescence properties show a strong wavelength dependency caused by a complex ground and excited-state behavior that makes it difficult to establish reference values. Moreover, the large fluorescence enhancement upon binding to amyloid fibrils that makes ThT a remarkable marker is also a challenge since the fluorescence properties of bound ThT cannot be easily related to those of the practically non-fluorescent free dye. 3.2 Fluorescence properties of bound Thioflavin T In this second part of the work we determine the binding constant of ThT to Aβ42 fibrils and the photophysical properties of the bound dye. These results are compared with those obtained for ThT bound to a non fibrillar protein and with the fluorescence properties of this dye in viscous media. The aim is to examine the difference between the fluorescence of ThT bound to amyloid fibrils as compared to other rigid media as well as to analyze the specificity of the dye to such fibrillar structures. Glycerol-water mixtures were used to obtain homogeneous media of increasing viscosities. Figure 2 shows the fluorescence titrations of ThT in aqueous solution with increasing volume percentage of glycerol, concentration of BSA or concentration of Aβ42. All measurements were performed under similar excitation conditions around the corresponding absorption maxima so 17 that mainly the long-wavelength emission is observed (see above). The emission spectra (grey curves, upper wavelength scale) are very similar in all three media, although broader for glycerol and BSA than for amyloid solutions. The emission maxima are slightly blue shifted in the order glycerol, BSA and amyloid. There is also a huge fluorescence enhancement (open circles in Figure 2) that follows a typical complexation profile both for BSA and for Aβ42. This increase in fluorescence is attributed to the binding of ThT to the peptides and a resulting steric hindrance for the dye to undergo the twisting process. By contrast, in glycerol-water mixtures the increase of the fluorescence intensity becomes only noticeable at high volume percentages of glycerol, where the viscosity increases enough to hinder the formation of the dark TICT state. Absorption titrations (Figure 2S in SI) show slight but systematic variations of the absorption spectrum of ThT in aqueous solution as the volume percentage of glycerol or the concentrations of BSA or Aβ42 are increased. A red shift is observed in all three media, indication for the redistribution of the ground-state equilibrium conformations with increasing contributions of planar conformations as the rotation is more and more hindered by the medium. In the case of BSA and Aβ42 these variations are due to the binding of ThT and suggest again that approximately planar conformations bind preferably to the peptides. For the glycerol-water mixtures the spectral variations are more significant at low volume percentage of glycerol, in contrast to the fluorescence enhancement (Figure 2), indicating that they are induced by polarity changes rather than by viscosity effects. 18 Figure 2. Fluorescence emission spectra (grey lines, upper scale) obtained in the titrations of ThT in aqueous solution with glycerol, BSA and Aβ42. The open circles represent the fluorescence intensities of ThT at the emission maximum as a function of the volume percentage of glycerol or the concentrations of BSA and Aβ42 (lower scale). In the case of BSA and Aβ42 the solid black lines were obtained by the fit of a 1:1 complexation model (eq. (1)) to the experimental data (for 19 the parameters see text). The grey squares are the mean anisotropy values r of ThT determined in the emission range 500-525 nm. All measurements were performed with an excitation wavelength of 410 ± 10 nm, except for the anisotropy at different concentrations of Aβ42, where 450 nm was used. Left scale: fluorescence intensity; right scale: anisotropy; bottom scales: volume percent or concentration; top scale: wavelength. Table 2. Photophysical properties of ThT in different media under excitation at 410±10 nm: absorption maximum υ ab , emission maximum υ em , steady-state anisotropy r (mean values of emission at 500-525 nm), fluorescence quantum yield φ , and fluorescence lifetimes τ (emission wavelength = 490±10 nm) with their corresponding contribution to fluorescence. The values given for BSA and Aβ42 were obtained from global analysis of the corresponding series of absorption and emission spectra and of fluorescence decays (see text). The last column shows the apparent binding constants K of ThT to BSA and Aβ42. ThT υ ab /cm- 1 υ em /cm-1 r φ τ1 / ns (%fluor) τ2 / ns (%fluor) K/ 103 mol-1 dm 3 Buffer sol. 24270 19960 0.36±0.01 0.00033 0.023±0.001 (81) 1.42±0.03 (19) - Chloroform 23530 19570 0.149±0.005 0.017 0.058±0.001 (46) 0.68±0.04 (54) - 99% Glycerol 23530 20240 0.381±0.003 0.15 0.286±0.003 (54) 0.685±0.008 (46) - BSA 24100 20370 0.378±0.004 0.055 0.566±0.006 (40) 2.225±0.007 (60) 1.35±0.01 Fibrillar Aβ42 23920 20580 0.350±0.002 0.31 0.82±0.01 (10) 2.37±0.01 (90) 5.85±0.07 In order to obtain the binding equilibrium constants and the spectra of ThT bound to BSA and to Aβ42, the whole series of emission spectra were analyzed with PCGA. PCA confirmed that each series can be reproduced by a linear combination of two components that are assigned to free and bound ThT. Then a 1:1 complexation model (eq. (1)) was used as fit function in the global 20 analysis of each series of emission spectra, yielding the binding constant K (Table 2) and the “pure” emission spectra of free and bound dye (Figures 3 and 3S in SI). Using a similar procedure, the series of absorption spectra (Figure 2S in SI) were analyzed with PCGA yielding the “pure” absorption spectra also shown in Figure 3 (K was fixed to the value obtained from emission data since the variations of the absorption spectrum are too small for a free fit of K). It was checked that the spectra obtained for the free dye coincide with those measured experimentally. The binding equilibrium constants determined with this analysis are given in Table 2. They are apparent constants resulting from the contribution of the different microscopic constants of each individual conformation and binding site. In the case of BSA, there is a good agreement with the value found in the literature [16]. No data are available for Aβ42, but the value obtained is significantly lower than those reported for other amyloid fibrils [2]. Nevertheless, it must be noted that most literature values are obtained by linearization methods such as Scatchard plots that imply strong assumptions and have high uncertainties. Moreover the high ThT concentrations that are often used lead to erroneous results, as already pointed out by other authors [12]. On the basis of these binding constants we can discuss the specificity of ThT to amyloid fibrils and asses its cross-sensitivity to other proteins. There are some reports that point to nonspecific binding of ThT but they lack quantitative data [22,24,45]. The affinity of the dye to Aβ42 fibrils is only about 4 times higher than to the α-helical protein BSA (Table 2). Furthermore, the binding constant of ThT to human serum albumin (HSA) is about 100 times than to BSA [16]. In a mixture of Aβ42 fibrils with BSA or HSA, a significant fraction of ThT would also bind BSA and almost of the dye would bind HSA. Therefore, the affinity of ThT to amyloid fibrils alone does not support its consideration as a specific probe for such fibrillar structures. We will now analyze the photophysical properties of the dye bound to amyloid fibrils in order to evaluate whether they are distinct enough to specifically discriminate these peptides. 21 Figure 3 (and 3S in SI) compares the spectra obtained for ThT bound to BSA and to Aβ42 with those measured in other media. Their corresponding maxima are given in Table 2. The absorption spectra (grey curves in Fig. 3) are very similar for all media, with a slight shift of about 700 cm-1 in glycerol and chloroform with respect to aqueous solution and nearly no shift for bound ThT. Thus no strong solvent dependency of the absorption maximum is observed, as stated in the literature [12]. The normalized emission spectra show also only small changes of their maximum with the environment, but are clearly different in their width. ThT bound to Aβ42 (solid black line) has the narrowest fluorescence band of all them, with a half width of 2800 cm-1, significantly smaller than for BSA and glycerol (dotted and dash-dot-dotted lines, half width ≈ 4000 cm-1). This difference in width suggests that the molecules of ThT bound to the amyloid fibrils are restricted to some subset of conformations with very uniform fluorescence properties. The fibrillar structure may favor particular conformations, probably those close to planarity. By contrast, the high viscosity of glycerol or the binding to BSA do not have such a selective effect. These spectral differences between ThT bound to Aβ42 and ThT bound to BSA may be exploited for the discrimination of different types of peptide. In aqueous solution and in chloroform there is an enhancement of the red emission resulting in band half widths that are nearly twice that in amyloid fibrils. This weak red emission becomes visible in the normalized spectra of these samples because of the much lower fluorescence quantum yield of the blue emission (Table 2). At 410 nm the perpendicular conformations are not effectively excited and in any case their emission is located at lower wavelengths (see Figure 1). Therefore this weak low-energy emission might be due to limiting ThT conformations or to an exiguous fluorescence of the TICT state. 22 Figure 3. Absorption (grey lines) and normalized fluorescence emission spectra (black lines) of ThT in different media under excitation at (410 ± 10) nm. The spectra of ThT in PBS buffer (dashed), chloroform (dash-dotted) and 99% glycerol (dash-dot-dotted) were measured directly. The spectra of ThT bound to BSA (dotted) and to Aβ42 (solid) are “pure” spectra obtained by global analysis of the corresponding series of absorption and emission spectra. (The spectra have been transformed to wavenumber taking into account the variation in bandpass 2 () () ν λλ = F II [34]. Spectra in the wavelength scale are given in Figure 3S in the SI.) Using the absorption and emission “pure” spectra determined above for ThT bound to BSA and Aβ42 and the experimental spectra of ThT in the different solvents and mixtures, the fluorescence quantum yields of ThT in the different media were calculated (Table 2 and open circles in Figure 4). The values obtained for the pure solvents agree quite well with reported data [12]. For glycerol-water mixtures we obtain significantly higher absolute quantum yields than those found in the literature [13]. This can be due to the different experimental conditions and quantum-yield standard used. Nevertheless, the viscosity dependence coincides with that reported, with an increase in φ of nearly 3 orders of magnitude from aqueous solution to 99% glycerol that is explained by the increasing hindrance of TICT formation as the solvent becomes more viscous (Figure 4 and Scheme 2). 23 ThT bound to Aβ42 shows the highest fluorescence quantum yield of all media (Table 2), with a value similar to those reported for other amyloid-type peptides [17,46,47]. In this case TICT formation is hindered due to the binding of the dye to the amyloid fibrils. When ThT binds to BSA the increase of φ is smaller. This might be due to a weaker dye-protein interaction or to the different binding mode of ThT with non fibrillar proteins. The fluorescence lifetimes determined for ThT in the different solvents and mixtures are shown in Table 2 and Figure 4. In all cases two lifetimes were necessary to fit the experimental decays. In aqueous solution the main contribution is from a species with very short lifetime that is attributed to planar conformations undergoing a rapid conversion to the dark TICT state, whereas the second longer lifetime could be due to a small fraction of the brighter perpendicular conformations (Scheme 2). Similar lifetimes are obtained in chloroform, although in this case they have equal contributions to the total fluorescence, in contrast to aqueous solution. For the glycerol-water mixtures also two lifetimes are obtained (Figure 4 and Table 2). The shorter one increases as the glycerol percentage is increased and contributes with about 90% to the measured fluorescence except at the highest glycerol percentages. The viscosity dependence of the lifetime is similar to that of the corresponding fluorescence quantum yield and can be explained likewise (Scheme 2). At low viscosities ThT has a short lifetime due to a conversion to the TICT state that is faster than the radiative deactivation. The twisting process is progressively more hindered as the viscosity is increased so that the TICT formation becomes slower and competes with the radiative deactivation leading to a longer lifetime. Neglecting the contribution of the second longer lifetime to the observed fluorescence, the nonradiative rate constant 1 (1 ) / φτ = − nr k can be estimated from φ and τ 1 in these mixtures (black triangles in Figure 4). The results show that knr, which is a measure of the conversion rate to the TICT state knr,TICT, drops very rapidly as the viscosity increases, reflecting the raising hindrance for the excited-state twisting process. This estimation is not valid for the highest volume percentages of glycerol since 24 there the contribution of the second lifetime is not negligible. Similarly to the other solvents, this longer lifetime can be attributed to perpendicular conformations with relatively high fluorescence intensity. The lifetimes obtained for ThT in 99% glycerol (Table 2) are compatible with those reported at other temperatures [13]. For BSA and Aβ42 time-resolved fluorescence titrations were performed by varying the protein concentration at a constant dye concentration. All decays are biexponential (apart from minor contributions associated to BSA impurities) and show the same two lifetimes but increasing amplitudes as the concentration of the peptide is increased. These results indicate that there are two emitting species in the presence of Aβ42 (or BSA) that behave as expected for bound ThT since their concentrations increase as the peptide concentration is increased. These species must be assigned to two distinct binding sites of ThT in the peptides that are related to conformations with different fluorescence properties and probably different binding affinities. Further analysis of the amplitudes will allow us to extract information about these two binding sites. Best estimates of the lifetimes (τ1 and τ2) and the amplitudes (A1 and A2) as obtained from global analysis of the series of fluorescence decays are given in Table 2 and Figure 4S in the SI. Figure 4. Fluorescence quantum yield φ (open circles), fluorescence lifetime τ 1 (open squares) and nonradiative deactivation rate constant knr (black triangles) of ThT in glycerol-water mixtures versus viscosity. The volume percentages of glycerol are the same as in Figure 2 (9.9, 24.7, 49.5, 25 59.4, 69.3, 79.2, 89.1 and 99.0%) and correspond to increasing viscosity values. The fluorescence quantum yields were obtained from the spectra shown in Figures 2 and 2S. Fits of the decays yield a second longer lifetime with low contribution and great uncertainty ( τ 2 = 0.6±0.1 ns) and two residual lifetimes associated to glycerol impurities. The nonradiative deactivation rate constant knr was calculated from φ and τ 1. Assuming independent complexation processes for the two binding sites, the macroscopic binding constant K determined from the fluorescence intensity (Table 2) is the sum of the microscopic binding constants K1 and K2 corresponding to site 1 (associated with τ1 and A1) and site 2 (τ2 and A2), respectively. Each amplitude is proportional to the fluorescence quantum yield and to the concentration of ThT at the corresponding binding site. Therefore, the fit of A1 and A2 to 1:1 complexation models (eq. (1)) with K1 and K2 as binding constants and under the constraint that 12 = +KKK (curves in Figure 4S) yields rough estimates of the microscopic binding constants and of the individual fluorescence intensities of ThT at the two binding sites (fluorescence percentages in Table 2). For the binding of ThT with Aβ42 the value of K1 is about 4 times higher than that of K2, indicating that ThT binds preferably to site 1. Nevertheless, when all the ThT is bound to Aβ42 then 90% of the observed fluorescence is due to ThT molecules in site 2 (see percentages in Table 2), which also have the longer lifetime. According to the photophysical model proposed (Scheme 2), ThT bound to site 2 must have essentially a planar conformation with a strong steric hindrance for the excited-state twisting so that it emits efficiently from the locally excited state. Thus, ThT bound to site 1 may correspond to nearly perpendicular conformations, characterized by a shorter lifetime and lower fluorescence intensity. The fact that most of the fluorescence comes from those ThT molecules bound to site 2 explains the narrow fluorescence band of ThT bound to Aβ42 (Figures 3 and 3S in SI).