Clin Oral Impl Res. 2021;00:1–12. | 1wileyonlinelibrary.com/journal/clr Received: 17 September 2020 | Revised: 11 March 2021 | Accepted: 17 June 2021 DOI: 10.1111/clr.13803 ORIGINAL ARTICLE De novo bone formation around implants with a surface based on a monolayer of multiphosphonate molecules. An experimental in vivo investigation Javier Sanz- Esporrin1,2 | Riccardo Di Raimondo1 | Fabio Vignoletti1 | Javier Núñez1 | Fernando Muñoz3 | Mariano Sanz1,2 This is an open access article under the terms of the Creative Commons Attribution- NonCommercial- NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is noncommercial and no modifications or adaptations are made. © 2021 The Authors. Clinical Oral Implants Research published by John Wiley & Sons Ltd. Supporting Information: ARRIVE guidelines checklist. 1Postgraduate Section of Periodontology, Faculty of Odontology, University Complutense of Madrid, Madrid, Spain 2ETEP (Etiology and Therapy of Periodontal and Periimplant Diseases) Research Group, University Complutense of Madrid, Madrid, Spain 3Ibonelab, Department of Veterinary Clinical Sciences, University of Santiago de Compostela, Lugo, Spain Correspondence Javier Sanz- Esporrin, Faculty of Odontology, Universidad Complutense de Madrid, Plaza Ramon y Cajal s/n, 28040 Madrid, Spain. Email:
[email protected] Funding information This study was partially funded through a research contract between the University Complutense of Madrid and MIS Implants (Israel) Abstract Objectives: The purpose of this experimental in vivo investigation was to evaluate the influence of modifying the implant surface by adding a monolayer of multiphosphonate molecules on the de novo bone formation and osseointegration. Material and Methods: The study was designed as an animal preclinical trial with intraanimal control and two healing periods, 2 and 8 weeks, to compare implants with an identical macrodesign but with two different surfaces. Eight female Beagle dogs participated in the study. Control implants had a moderately rough surface combining sandblasting and acid etching; test implants had an additional monophosphonate layer covalently bonded to titanium. Histologic and radiographic (micro- CT) outcome variables were evaluated. Results: The first bone- to- implant contact (fBIC) was located more coronally for the test implants at the first (0.065 mm (95% CI = −0.82, 0.60)) and second healing milestones (0.17 mm (95% CI = −0.9, 0.55)). Most coronal BIC of the test implants displayed a higher percentage of osseointegration, +6.33% and +13.38% after 2 and 8 weeks, respectively; however, the differences were not statistically significant. The micro- CT examination did not show any BIC difference. Conclusions: The monophosphonate layer coating demonstrated clinical, histological, and radiographic results similar to the control surface. KEYWORDS animal model, dental implants, histology, implant surface, osseointegration, monophosphonate layer, wound chamber, histometric analysis, micro- CT
2 | SANZESPORRIN Et Al. 1 | INTRODUCTION Since the first description of the osseointegration phenomenon (Albrektsson et al., 1981; Branemark et al., 1969, 1977), the healing of dental implants placed in alveolar bone has been extensively studied providing clear histological documentation on the biological cascade of events that guides bone and soft tissue healing around dental implants (Berglundh et al., ,2003, 2007). Surface treatment modifications have been a field of great research interest seeking to improve the dynamics of osseointegration and the quality and quantity of bone- to- implant contact (Junker et al., 2009). An increase in surface roughness was the first modification that demonstrated an increase in bone apposition (Abrahamsson et al., 2004; Buser et al., 1991; Wennerberg et al., 1995), and a reduced nonloading time between implant placement and prosthetic restoration (Lazzara et al., 1998). In fact, significantly higher success and survival rates were reported when moderately rough surfaces were compared with machined surfaces (Cochran, 1999). Other modifications have included different surface coatings, such as hydroxyapatite coatings, but the latter may be infected and lead to unwanted tissue reactions (Abrahamsson et al., 2013; Albrektsson et al., 2008; van Oirschot et al., 2013; Wheeler, 1996). Research efforts have evolved toward modifying the chemical structure of titanium by incorporating fluoride ions (Ellingsen et al., 2004) or by augmenting the surface wettability when implants are maintained submerged in an isotonic NaCl solution (Buser et al., 2004). Another chemical surface treatment modification has been the application of a covalently bonded layer of monophosphonate molecules on titanium. The presence of Ti- O- P bound is clearly depicted by XPS analysis demonstrating a strong covalent bound that provides stability, thus producing an ultrathin layer that covers the microtextured surface, which prevents the peeling off the underground surface, as it happens with conventional thick coatings. The aim of this surface treatment was to attract and stimulate boneforming cells, thus providing this surface with osteoconductive properties. This effect has been demonstrated in vitro (Viornery et al., 2002) but has not been tested in oral environment in preclinical experimental studies. It was, therefore, the purpose of this experimental in vivo investigation was to study the histological and radiographic response of de novo bone formation on this novel implant surface compared with implants with identical macrodesign but without this very surface chemical modification. 2 | MATERIAL AND METHODS 2.1 | Study design and randomization The study was designed as a preclinical trial with twotime healing periods (2 and 8 weeks after implant placement) comparing two implants with identical macrodesign but different surface characteristics. Beagle dog was chosen as experimental model. The study protocol consisted on four interventions: (i) tooth extraction, (ii) implant placement (healing T8), (iii) implant placement (healing T2), and (iv) euthanasia and subsequent histological processing and evaluation. The experimental sites were randomly allocated to either test or control according to a computergenerated randomization list (IBM SPSS Statistics® V20. JM. Domenech). Randomization sequence was generated using a blocking, balanced restricted randomization, stratified by hemimandible and implant position (P1- P5). Furthermore, each hemimandible (left or right) randomly allocated one healing time point (T2 or T8). Allocation to the treatment was concealed by means of sealed envelopes containing the implant type, which were opened during the surgical procedure once the flaps were raised and the bone was exposed. 2.2 | Experimental sample A total of eight healthy adult female Beagle oneyear- old dogs (mean weight 14.63 kg) (Isoquimen, Barcelona, Spain) were used in this experimental in vivo investigation, in full compliance with the ARRIVE guidelines. The Ethical Committee of the Jesús Usón Minimally Invasive Surgical Center (Cáceres, Spain) approved the study protocol (ES register number: 201520930011504). The animals were housed in the Animal experimentation Service Facility of the Jesús Usón Minimally Invasive Surgical Center (Cáceres, Spain), and the surgeries were carried out in the same premises from January 2016 to May 2016. All the experiments were performed according to the Spanish and European regulations about care and use of research animals; the dogs were monitored daily during the study by a veterinarian accredited in laboratory animal science. According with animal welfare, vaccine and antiparasitic drugs were administrated upon arrival; they were then identified with a microchip and housed in pairs. Animal housing conditions were room temperature between 18 and 29°C, 30%– 70% of relative humidity, and 15 min air renewal per hour. A 12 hr light/dark cycle with intensity control was established; feeding and water intake was evaluated daily. The experimental segment of the study started after an adaptation/quarantine period of 3 weeks. 2.3 | Study devices Implants were MIS® C1 implants (MIS implants technologies LTD, Israel), with 3.5 mm of diameter and 9 mm of length. All implants presented a moderately rough surface with and Sa of 1.22 ± 0.09. Implants presented the same macroscopic design (Figure 1h), which included a customized modification by creating a 0.40- mm deep U- shaped circumferential trough within the thread region (intraosseous portion), although leaving the tip of each thread untouched (Figure 1i). In this manner, an experimental wound chamber was created following implant installation to allow for a validated study of the bone healing and osseointegration after implant placement (Abrahamsson et al., 2004; Berglundh et al., 2003).
| 3 SANZESPORRIN Et Al. The surface of test implants included a covalently bonded phosphonate treatment that created a nanometer thin molecular nanolayer of monophosphonate molecules, also known as phosphonic acids (Nano Bridging Molecules, Gland, Switzerland), without altering the geometry and roughness of the implant surface. Unlike phosphates, phosphonic acids (phosphonates) are a family of organophosphorus compounds, which make them able to react and connect to the titanium oxide surface. The control surface presented the conventional moderately rough MIS implant surface based on sandblasting and etching, without the monophosphonate chemical treatment. Both test and control implants presented the same roughness (moderately rough– Sa 1.22 ± 0.09). Fabrication process of the test implant surface treatment is protected by the patent (EP1698357), which is commercially available under the product name MIS B+® (MIS implants technologies LTD, Israel). In total, 40 tests and 40 control implants were placed. From those, 20 test and 20 control implants were placed in the 2- week healing group hemimandibles and 20 test and 20 control implants were placed in the 8- week healing group hemimandibles. In each hemimandible, both test and control implants were placed according to random allocation in the corresponding healing period. 2.4 | Surgical procedures All surgical interventions were performed under sterile conditions, in an animal operating theater and under general anesthesia induced by Propofol (3– 5 mg/kg/i.v., Propovet®, Abbott Laboratories, Kent, UK) and maintained on a concentration of 2.5%– 4% of isoflurane (Isobavet®, Schering- Plough, Madrid, Spain). The animals were first premedicated with medetomidine (20 μg/kg/i.m., Domtor, Esteve, Barcelona, Spain) and the pain controlled with the administration of morphine (0.4 mg/kg/i.m., Morfina Braun 2%, B. Braun Medical, Barcelona, Spain). During anesthesia, the animals were continuously monitored by a veterinarian category B or C, controlling electrocardiography, capnography, pulsioxymetry, and noninvasive blood pressure. Prophylactic administration of Cephazolin (20 mg/kg/i.v., Kurgan, Normon, Madrid, Spain) and Cefovezin (8 mg kg- 1 s- 1 .i.d./s.c., Convenia, Zoetis, Madrid, Spain) was performed intraoperatively. At the end of the procedures, Atipamezole (50 mg/kg/i.m., Esteve, Barcelona, Spain) was administered to revert the effects of Medetomidine. Postoperative pain was controlled by administration of morphine (0.2 mg/kg/i.m./6 hr, Morfina Braun 2% B. Braun Medical, Barcelona, Spain) and meloxicam as antiinflammatory and analgesic treatment (0.2 mg/kg/i.m./SID, Metacam, Boehringer Ingelheim, Barcelona, Spain) for 5 days. The surgical protocol used in this study has been was recently reported in detail in another publication from our research group (Vignoletti et al., 2019). In brief: 2.4.1 | Phase 1: tooth extraction Extraction of mandibular 2P2, 3P3, 4P4 premolars, and the mesial root of 1M1 was carried out in both jaws, once teeth were hemisected using a flapless procedure. (Figure 1a– c). FIGURE 1 Clinical stages of the experiment. (a) Baseline situation. (b) Teeth hemisection prior to extraction. (c) Suture after teeth extraction. (d) Healed crest 3 months after extractions. (e) Implant osteotomies. (f) Implant placement. (g) Suture after implant placement. (h) Identical macroscopic design of test and control implants. (i) Wound chamber thread design; increased 0.40- mm deep U- shaped valley between threads to allow bone healing study (a) (b) (c) (d) (e) (f) (g)(i)(h)
4 | SANZESPORRIN Et Al. 2.4.2 | Phase 2: implant placement (8- week healing group) Fullthickness buccal and lingual flaps were elevated from distal of the cuspid to distal of M1 and 3 mm of the alveolar ridge was exposed. Once the appropriate osteotomies were done and after randomization and implant allocation, implants were inserted following the standard manufacturing instructions. Implants were placed at the level of the crest (bone level), taking as reference buccal plate. In some of the cases, lingual aspect of the implant remained subcrestally located, as the crest presented irregular shape with a more apical buccal bone place with respect to the lingual plate. Healing abutments were secured, and flaps were sutured to allow for transmucosal healing. A total of five implants were placed in each hemimandible following randomization. (Figure 1d– g). Postoperatively, the animals had professional plaque control consisting the application of gauzes embedded in chlorhexidine solution 0.12% (Perio- Aid Treatment®, Dentaid, Cerdanyola del Valles, Spain) three times a week during the first two weeks and then 3 times a week with toothbrush and chlorhexidine gel. Surgeries were performed in one randomized (left or right) hemimandible of each dog, leaving the contralateral hemimandible for the 2- week healing group). Each hemimandible harbored both, test and control implants, allocated in a randomized sequence. 2.4.3 | Phase 3: implant placement (2- week healing group) Two weeks prior to euthanasia, the same surgical procedure and postoperative protocol were performed in the contralateral corresponding hemimandible according to the randomization sequence. In total, 40 tests and 40 control implants were placed, 20 test and 20 control implants in the 2- week healing group and 20 test and 20 control implants in the 8- week healing group. 2.4.4 | Phase 4: euthanasia After 2 weeks of healing, dogs were first sedated with medetomidine (30 μg/kg/i.m., Esteve, Barcelona, Spain) and then euthanized with an intravenous overdose of sodium pentobarbital (40– 60 mg/ kg/i.v., Dolethal, Vetoquinol, France). Subsequently, the lower jaws were dissected and retrieved with intact soft tissues and fixed in buffered 10% formaldehyde solution. Previous to histological processing, the implants were individually separated using a band saw for micro- CT scanning. 2.5 | Micro- CT analysis All specimens were scanned before being sectioned using a highresolution micro- CT (Skyscan 1,172, Bruker micro- CT NV, Kontich, Belgium). The X- ray source was set at 100 Kv and 100 μA with a voxel size of 12 μm and an Aluminum/Copper filter (Al/Cu). Scanning was performed over a 360º rotation acquiring images every 0.4º. Once scanned, the images were reconstructed based on the Feldkamp algorithm using the NRecon software (Bruker micro- CT NV, Kontig, Belgium). The reconstructed images were evaluated with the Data Viewer software (Bruker micro- CT NV, Kontig, Belgium) and rotated to ensure that the implant was perfectly aligned. A VOI of 4 mm of length was selected in the middle of the implant for all the samples, including all the surrounding bone in the four directions (distal, mesial, buccal, and lingual). After selecting the volume of interest (VOI), data were analyzed using the CTAn software (Bruker micro- CT NV, Kontig, Belgium). Firstly, a circular VOI of 5 mm of diameter was selected. Then, images were segmented using adaptative local thresholding methods, selecting the best threshold parameters for bone and for implant. The following outcomes were measured: (a) bone- to- implant contact (BIC; %) expressed as 360º bone- to- implant contact (intersecting bone), (b) implant volume and bone volume (%) using the method described by Bruker in the method note (074) “Osteointegration: analysis of bone around a metal implant” (January 2015), expressed as Bone volume/Tissue volume. (Figures 2 and 3). 2.6 | Histological processing Using a randomization protocol, half of the blocks containing the implant and the surrounding hard and soft tissues were dissected and processed for ground sectioning following the method described by Donath and Breuner (Donath & Breuner, 1982). The samples were dehydrated in a graded series of ethanol solutions and embedded in a lightcuring resin (Technovit 7,200 VLC; Heraeus- Kulzer GMBH, Werheim, Germany). To assure sectioning the implants in the longitudinal axis, the resin blocks containing the implants and adjacent tissues were radiographed in a buccallingual direction and using a ruler and a negatoscope, pencil lines were traced over the surface of the block to guide the sectioning of the block with a bandsaw equipped with a laseraided orientation device (Exakt Apparatebau, Norderstedt, Germany). After sectioning, polishing was performed mechanically using 1,200 and 4,000 grit silicon carbide papers (Struers, Copenhagen, Denmark). Finally, the blocks attained a final tissue thickness of about 30 μm. The slides were stained according to the Levai Laczkó method (Jeno & Geza, 1975). The second half of the specimens were prepared for decalcification following the “fracture technique” protocol described by Berglundh et al. (Berglundh et al., 1994). 2.7 | Histomorphometric analysis The histometric evaluation was carried out using a Nikon Eclipse Ti microscope (Nikon, Heidelberg, Germany) equipped with image analysis software (Q- 500MC; Nikon). One buccolingual section per
| 5 SANZESPORRIN Et Al. implant was analyzed. All measurements were evaluated by two calibrated investigators masked to the specific experimental conditions (JS and RDR). The calibration test consisted on repeated evaluation of the bone- to- implant contact over the first section of each animal. Resulting interexaminer intraclass correlation coefficient was 0.988 (95% confidence intervals: 0.982– 0.999); intraexaminer intraclass FIGURE 2 Two weeks healing micro- CT volumetric reconstructions FIGURE 3 Eight weeks healing micro- CT volumetric reconstruction and frequency distribution histogram of results
6 | SANZESPORRIN Et Al. correlation coefficients were 0.999 (95% confidence intervals: 0.998– 1.000) for JS and 1.000 (95% confidence intervals: 0.999– 1.000) for RDR. The following landmarks were identified on both the buccal and lingual sides in each implant (Figure 4): • Implant shoulder (I), • The first coronal level of bone in contact with the implant (B), • Bone crest, defined as the most coronal point of bone (Bc). Using these landmarks, the following linear measurements were calculated in millimeters at both the buccal and lingual aspects: • I - B c • I - B • B c - B The percentage of bone- to- implant contact (BIC) was calculated along a selected surface on the buccal and lingual aspects of test and control implants. BIC was evaluated at the most coronal portion (3 mm) as well as on the entire surface (6 coronal mm) of the implant (Figure 5). The area of the wound chamber was selected (Figure 6), and percentages of each tissue component were calculated considering the total wound chamber area as 100%. The areas of newly formed bone and parent bone were measured within the wound chamber. Three wound chambers (buccal and lingual) were analyzed for each implant (Abrahamsson et al., 2004; Berglundh et al., 2003). 2.8 | Statistical analysis Data from both histological and micro- CT analysis were expressed in means (±SD), considering the dog as the statistical unit of analysis (n = 8). The data were tested for normality by means of a Shapiro– Wilk test. Comparisons between experimental/control implants and between 2- and 8- week healing periods were analyzed using the twoway ANOVA and compared using generalized estimation model with intragroup comparisons. Bonferroni post hoc analysis was further performed to evaluate differences between the time intervals. Differences were considered statistically significant when p was <.05. This statistical analysis was performed using the software SPSS (SPSS® 20.0, SPSS Inc., Chicago, IL, USA). 3 | RESULTS 3.1 | Clinical findings Healing of animals was uneventful in all dogs. All implants demonstrated clinical signs of adequate osseointegration and were available for histological processing. 3.2 | Histological Findings 3.2.1 | Early Healing (2 weeks) The lingual bone crest was usually positioned coronally with respect to the implant shoulder, while the buccal bone crest was at the same level, although the first bone to implant contact was located apical to this reference. Woven bone formation represented the main histological observation within the wound chamber area in both groups, FIGURE 4 Histological landmarks: IS: Implant Shoulder. BC: Bone Crest. B: First bone– toimplant contact FIGURE 5 Histological bone to implant contact measurement. Coronal BIC: bone in contact with implant surface within the 3 coronal millimeters from implant shoulder. Total BIC: bone in contact with implant surface within the 6 coronal millimeters from implant shoulder
| 7 SANZESPORRIN Et Al. with this woven bone directly in contact with the implant surface. Fingerlike projections of woven bone were intercalated with nonmineralized tissue. Mature bone was observed in the thread area depicting areas of modeling and remodeling (Figure 7). No major differences were observed between the groups. 3.2.2 | Late Healing (8 weeks) There was a slight resorption of the lingual bone crest, being positioned in close proximity to the implant shoulder. Similarly, the first bone- to- implant contact was observed in a more coronal position compared with the 2- week healing sections. Woven bone had been substituted by lamellar bone in contact with the implant surface. (Figure 8). 3.3 | Histometric results The linear vertical measurements and BIC % are reported in (Figures 9 and 10) (Table 1). A total of 29 ground sections were available for analysis. I- B. At two weeks, buccal and lingual average measurements showed that the first bone- to- implant contact was located FIGURE 6 Wound chamber tissue area assessment FIGURE 7 Histological section of 2- week healing implants. Note the discrepancy between crestal bone and first bone– toimplant contact (located apically with respect to implant shoulder, for both the test and control implants) FIGURE 8 Histological section of 8- week healing implants. Note reduction in discrepancy between the apicocoronal position of the crestal bone and the first bone- to- implant contact in both implants
8 | SANZESPORRIN Et Al. approximately 0.7– 0.8 mm apical to the implant shoulder; no differences between the groups was identified. After 8 weeks of healing, the test implants showed a significant reduction in the distance between implant shoulder and first bone- to- implant contact. The first coronal level of bone contact (B) was observed at 0.47 (SD 0.19) and 0.64 (SD 0.19) for test and control groups, respectively. Differences between groups were not statistically significant. I- Bc. Bone crest was close to implant shoulder at two weeks in both groups (test group, 0.08 mm SD = 0.5 versus. control group −0.06 mm SD = 0.28). After 8 weeks of healing, bone crest was located at 0.37 (95% CI = 0.92, 0.18) and 0.43 mm (95% CI = 0.92, 0.07) for the test and control groups, respectively. Intergroup differences were not statistically significant. Bc- B. The distance between the bone crest and first bone- to- implant contact was reduced between 2 and 8 weeks. This reduction was as a combination of apical displacement of crestal bone and coronal growth of the first bone- to- implant contact. That reduction in distance was higher for the test (0.67 mm (95% CI = −0.16, 1.50)) compared with the control (0.62 mm (95% CI = −0.13, 1.37)). These differences between test and control were not statistically significant. 3.3.1 | Bone- to- implant contact (%BIC) At two weeks, similar mean coronal BIC values were observed between groups (Table 2). An increase in mean BIC was observed after 8 weeks in both groups. Although a higher mean BIC value was observed for the test (74.84) when compared to control (59.46), this difference was not statistically significant. 3.3.2 | Histometrical area of tissue in the wound chambers (B and ST) At 2 weeks, the mean area of newly formed bone was higher in control implants compared with test implants (33.48% SD = 12.44% versus 26.46% SD = 11.71, respectively) (Table 3). At eight weeks, newly formed bone area was the same between control and test implants (25.43% SD = 7.87% versus 26.36% SD = 8.50). Differences between groups were not statistically significant. 3.4 | Micro- CT results Similar bone volume/tissue volume results were observed between test and control at 2 weeks (Table 4). Values increased in the same amount regarding test and control at 8 weeks. Around 50% of 360º radiographic bone- to- implant contact was observed in test and control at 2 weeks. A significant increase in 360º radiographic bone- to- implant contact was observed at 8 weeks in both, test and control implants (72.88% SD = 8.50% versus 70.75% SD = 7.58, respectively). Differences between groups were not statistically significant. (Figure 10). FIGURE 9 Graphical representation of linear and surface histological measurements FIGURE 10 Graphical representation of histological and radiographical bone- to- implant contact and BV/TV micro- CT results
| 9 SANZESPORRIN Et Al. 4 | DISCUSSION The present experimental in vivo investigation was designed to study the histological and radiographical outcomes of a new implant surface treatment based on a monolayer of multiphosphonate molecules, compared with a standard moderately rough implant surface, during the early and late phases of osseointegration. The novel implant surface showed a more coronal first bone- to- implant contact and a higher amount of bone- to- implant contact in the coronal third of the implant to bone interface. Furthermore, the radiographic 360 BIC percentages were superior in test group both during the early and late healing periods. At eight weeks, 360º BIC accounted for 80% approximately in the test implant, while in the control implant it was 70% (Figure 3). Similar outcomes were observed histologically. However, these differences did not reach statistical significance in any of the time evaluations when comparing the two tested implants. TABLE 1 Histometrical first bone contact distance (I- B) (mean ± SD), bone crest distance (I- BC) (mean ± SD) and first bone- to- implant contact to crest distance (BCB) (mean ± SD) in different groups: 2- week healing, 8- week healing in both implant groups Group I- B 2W (mm) I- B 8W (mm) I- BC 2W (mm) I- BC 8W (mm) BCB 2W (mm) BCB 8W (mm) Test 0.77 ± 0.5 0.47 ± 0.19 0.08 ± 0.5 0.45 ± 0.24 0.69 ± 0.47 0.02 ± 0.20 Control 0.84 ± 0.54 0.64 ± 0.59 −0.06 ± 0.28 0.36 ± 0.34 0.90 ± 0.57 0.29 ± 0.67 Δ Test- Control 0.065 0.17 0.15 0.09 0.21 0.26 95% CI (−0.82– 0.69) (−0.9– 0.55) (−0.39– 0.68) (−0.42– 0.60) (−1.02– 0.60) (−1.04– 0.51) Note: Means of buccal and lingual measurements are presented. *Comparisons between groups (ANOVA test). p < .05. No statistically significant differences were found. Group BIC 3 mm 2W (%) BIC 3 mm 8W (%) BIC 6 mm 2W (%) BIC 6 mm 8W (%) Test 47.44 ± 13.81 72.84 ± 5.77 52.07 ± 14.97 73.99 ± 6.91 Control 41.11 ± 11.60 59.46 ± 14.86 46.92 ± 5.15 70.27 ± 7.94 Δ Test- Control 6.33 13.38 5.14 3.72 95% CI (−12.34– 25.00) (−4.51– 31.27) (−8.81– 19.10) (−4.51– 31.27) Note: Means of buccal and lingual measurements are presented. *Comparisons between groups (ANOVA test). p < .05. No statistically significant differences were found. TABLE 2 Histometrical % bone- to- implant contact (BIC) in the 3 and 6 coronal mm of the implant surface in different groups: 2- week healing, 8- week healing in both implant groups Group B 2W (%) B 8W (%) ST 2W (%) ST 8W (%) Test 26.46 ± 11.71 26.36 ± 8.50 73.54 ± 11.71 73.63 ± 8.50 Control 33.48 ± 12.44 25.43 ± 7.87 66.52 ± 12.44 74.57 ± 7.87 Δ Test- Control 7.02 0.94 7.02 0.94 95% CI (−22.91– 8.87) ( − 1 4 . 2 9 – 1 6 . 1 7 ) (−8.87– 22.91) ( − 1 6 . 1 7 – 1 4 . 2 9 ) Note: Means of buccal and lingual measurements are presented. *Comparisons between groups (ANOVA test). p < .05. No statistically significant differences were found. TABLE 3 Histometrical % area of mineralized tissue (B) and % area of soft tissue (ST) in different groups: 2- week healing, 8- week healing in both implant groups Group BV/TV 2W BV/TV 8W 360 BIC 2W (%) 360 BIC 8W (%) Test 45.99 ± 9.61 61.47 ± 12.50 53.86 ± 6.94 72.88 ± 8.50 Control 46.37 ± 7.02 58.18 ± 11.35 53.85 ± 4.81 70.75 ± 7.58 Δ Test- Control 0.37 3.30 0.01 2.12 95% CI ( − 1 5 . 0 3 – 1 4 . 2 9 ) ( − 1 1 . 3 6 – 1 7 . 9 6 ) (−10.05– 10.08) (−7.94– 12.19) *Comparisons between groups (ANOVA test). p < .05. No statistically significant differences were found. TABLE 4 Micro- CT radiographic bone volume/tissue volume (BV/TV) and % 360º bone- to- implant contact (360 BIC) of the complete implant surface in different groups: 2- week healing, 8- week healing in both implant groups