3D printed teeth in endodontics: Why, How, Problems and Future. A new Protocol for Micro-CT studies
Abstract
3D printed teeth have the potencial to establish a new standard in endodontic ex vivo studies and endodontic training, potentially supplanting natural teeth. This thesis aimed to identify and try to solve problems that 3D printed teeth in endodontics still present. The primary aims were (1) to evaluate the impact of support material of a commercial tooth replica, on the preparation technique and its potential effects on the volume increase evaluation using micro-CT scans and, (2) to develop and validate a protocol for complete removing support material from 3D printed teeth and assessing its efficacy by comparing the internal anatomy of a natural tooth with 3D printed teeth using micro-CT.
Full text
INTERNATIONAL DOCTORAL SCHOOL OF THE USC Tiago Filipe Dos Santos Sousa Reis Faria PhD Thesis 3D PRINTED TEETH IN ENDODONTICS: WHY, HOW, PROBLEMS AND FUTURE. A NEW PROTOCOL FOR MICROCT STUDIES Santiago de Compostela, 2024 Doctoral Programme in Dental Science
DOCTORAL THESIS 3D PRINTED TEETH IN ENDODONTICS: WHY, HOW, PROBLEMS AND FUTURE. A NEW PROTOCOL FOR MICRO-CT STUDIES Author Tiago Filipe dos Santos Sousa Reis Faria Supervisors: Benjamín José Martín Biedma José Martín Cruces Tutor: Benjamín José Martín Biedma PHD PROGRAMME IN DENTAL SCIENCES SANTIAGO DE COMPOSTELA / LUGO 2024
PUBLICATION DERIVED FROM THIS THESIS Title: 3D Printed Teeth in Endodontics: Why, How, Problems and Future - A Narrative Review Authors: Tiago Reis1,2,*, Cláudia Barbosa3, Margarida Franco4, Catarina Baptista4, Nuno Alves4, Pablo Castelo-Baz1, José Martin-Cruces1 and Benjamin Martin-Biedma1 Affiliation: 1 Department of Surgery and Medical-Surgical Specialties, School of Medicine and Dentistry, University of Santiago de Compostela, 15701 Santiago de Compostela, Spain 2 Faculty of Health Sciences, University Fernando Pessoa, Porto, Portugal 3 FP-I3ID, Faculty of Health Sciences, University Fernando Pessoa, Porto, Portugal 4 CDRSP, Polytechnic Institute of Leiria, Marinha Grande, Portugal * Correspondence Journal: International Journal of Environmental Research and Public Health. Impact Factor 2021: 4.614 JCR Category 2021: Q1 CiteScore 2022: 5.4 SJR 2022: 0.828 ISSN: 1661-7827 Editorial: Multidisciplinary Digital Publishing Institute (MDPI) Publication Date: 29 of June of 2022 PMID: 35805624 DOI: https://doi.org/10.3390/ijerph19137966 Tiago Filipe dos Santos Sousa Reis Faria Contribution: Conceptualization and writing—review and editing
PUBLICATION DERIVED FROM THIS THESIS Title: Root Canal Preparation of a Commercial Artificial Tooth versus Natural Tooth - A MicroCT Study Authors: Tiago Reis1,2,* Cláudia Barbosa2, Margarida Franco3, Catarina Batista3, Nuno Alves3, Pablo Castelo-Baz1, José Martin-Cruces1 and Benjamín Martin-Biedma1 Affiliation: 1 Department of Surgery and Medical-Surgical Specialties, School of Medicine and Dentistry, University of Santiago de Compostela, 15701 Santiago de Compostela, Spain 2 FP-I3ID, Faculty of Health Sciences, University Fernando Pessoa, 4249-004 Porto, Portugal 3 CDRSP, Polytechnic Institute of Leiria, Marinha Grande, 2430-028 Marinha Grande, Portugal * Correspondence Journal: Applied Sciences Impact Factor 2022: 2.7 JCR Category 2022: Q2 CiteScore 2022: 4.5 SJR 2023: 0.51 E-ISSN: 2076-3417 Editorial: Multidisciplinary Digital Publishing Institute (MDPI) Publication Date: 18 of August of 2023 DOI: https://doi.org/10.3390/app13169400 Tiago Filipe dos Santos Sousa Reis Faria Contribution: Conceptualization and writing—review and editing
PUBLICATION DERIVED FROM THIS THESIS Title: Three Dimensional Printed Teeth in Endodontics: a new protocol for Microcomputed tomography studies Authors: Tiago Reis1,2,3 *, Cláudia Barbosa3,4, Margarida Franco2, Ruben Silva2, Nuno Alves2, Pablo Castelo-Baz5, José Martin-Cruces1 and Benjamin Martin-Biedma5 Affiliation: 1 Endodontics and Restorative Dentistry Unit, School of Medicine and Dentistry, University of Santiago de Compostela, 15701 Santiago de Compostela, Spain 2 Centre for Rapid and Sustainable Product Development, CDRSP, Polytechnic University of Leiria, Leiria Portugal 3 FP-I3ID, FP-BHS, Health Sciences Faculty, University Fernando Pessoa, Porto, Portugal 4 RISE-Health, University Fernando Pessoa, Porto; Portugal 5 Oral Sciences Research Group, Endodontics and Restorative Dentistry Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela, Spain * Correspondence Journal: Materials Impact Factor 2022: 3.4 JCR Category 2022: Q2 CiteScore 2022: 5.2 SJR 2023: 0.57 E-ISSN: 1996-1944 Editorial: Multidisciplinary Digital Publishing Institute (MDPI) Publication Date: 19 of April of 2024 DOI: https://doi.org/10.3390/ma17081899 Tiago Filipe dos Santos Sousa Reis Faria Contribution: Conceptualization, methodology, software, validation, resources, data curation, writing-original draft preparation and writing—review and editing
CONFLICTS OF INTEREST DECLARATION TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA, DECLARE NO CONFLICTS OF INTEREST RELATED TO THE PRESENT DOCTORAL THESIS 3D PRINTED TEETH IN ENDODONTICS: WHY, HOW, PROBLEMS AND FUTURE. A NEW PROTOCOL FOR MICRO-CT STUDIES
DEDICATÓRIA A Cláudia, José y Manuel ¡Son la razón de que esta caminada, llamada vida, merezca la pena! A mis Padres Por el amor incondicional que siempre me han dado
“ EVERYTHING IS INTERESTING, IF YOU GO INTO DEEPLY ENOUGH” RICHARD FEYNMAN
AGRADECIMIENTOS A todas las personas que, de una forma u otra, me ayudaron y contribuyeron al desarrollo de esta tesis. En especial quiero dar las gracias, Al Profesor Doctor Benjamín José Martín-Biedma, por su dedicación, paciencia y apoyo durante estos años de doctorado. Que la amistad que nació se mantenga y se prolongue en los años venideros. Fue un verdadero placer trabajar juntos. Al Profesor Doctor José Martín-Cruces por su ayuda y apoyo durante el desarrollo de esta tesis. A la Dra. Margarida Franco por su enorme paciencia con mi cabezonería, su apoyo y por todas las horas que trabajamos juntos haciendo Micro-CT. Esta tesis no hubiera sido posible sin su enorme dedicación. Gracias sobre todo por su verdadera amistad. ¡Que vengan más proyectos! Al Profesor Doctor Nuno Alves, por todo su apoyo al permitirme el acceso incondicional al CDRSP. A la Profesora Doctora Sandra Gavinha por su amistad, apoyo y ayuda que fueran fundamentales para ultrapasar uno de los momentos más desafiantes de mi vida y que se mantienen hasta el día de hoy. Nunca lo olvidaré y le estaré eternamente agradecido. Muchas gracias. A la Profesora Doctora Patrícia Manarte, por ser la primera persona que plantó la semilla del doctorado en mi cabeza. Gracias por creer en mí. A toda mi familia y a todos mis colegas y amigos que me han acompañado en estos últimos años y me han dado fuerzas para seguir adelante, son demasiados para enumerarlos, pero ustedes saben quiénes son.
Endodontics Company) utiliza unha lima menos en comparación co sistema ProTaper Gold® (Dentsply-Sirona). Así mesmo, observáronse diferenzas estatisticamente significativas entre a lima ProGlyder® (Dentsply Sirona) e a lima A (Endogal, Galician Endodontics Company). O tempo de preparación rexistrado foi de 27,30 segundos para a ProGlyder® (Dentsply Sirona) e de 6,90 segundos para a lima A (Endogal, Galician Endodontics Company), mentres que os movementos de picoteo foron de 14,70 e 5,10 respectivamente. A lima ProGlyder® (Dentsply Sirona) caracterízase por un tamaño de punta de 0,16 mm e unha conicidade variable que oscila entre o 2% e o 8,5% (Alovisi et al., 2017; Gambarini et al., 2021; Keskin et al., 2020; Kirchhoff et al., 2015; Paleker & van der Vyver, 2017). Pola contra, a lima A (Endogal, Galician Endodontics Company) mantén unha conicidade consistente do 3% cun tamaño de punta de 0,15 mm (Castelo-Baz et al., 2023; Endogal; Faus-Matoses et al., 2022; Ruiz-Pinon et al., 2021). Aínda que ambas limas comparten un tamaño apical similar, as diferenzas no deseño de sección transversal e conicidade poden explicar estas distincións. Como se dixo anteriormente, aínda teñen que desenvolverse protocolos para a estandarización dos estudos utilizando dentes impresos en 3D (Hulsmann, 2022), os nosos resultados, dentro das súas limitacións, presentan unha descrición dun protocolo eficaz para a eliminación do material de soporte SUP706B™, demostrando que os dentes impresos en 3D impresos con o material RGD525™ de alta temperatura ten un comportamento similar á preparación de endodoncia que os dentes naturais. Non obstante, a investigación futura é necesaria para estandarizar os estudos que impliquen dentes impresos en 3D. Isto implica determinar a orientación óptima na cama da impresora para os dentes con varias raíces, decidir o nivel de simplificación para o ficheiro STL sen sacrificar información, avaliar a eficacia do protocolo de eliminación de material de soporte para varias morfoloxías de raíces e comprender como as variacións de rpm, torque, a amplitude dos movementos de picoteo e o deseño da lima poden afectar a preparación dos dentes impresos en 3D. Na secuencia destes resultados pódese concluír que: 1. Na análise 3D do canal mesiovestibular dos dentes artificiais, o aumento medio do volume do canal radicular resultou negativo, o que indica que o material de soporte influíu na análise 3D Micro-CT da variable en consideración. 2. Non se atoparon diferenzas estatisticamente significativas no tempo e no número de movementos de picoteo entre os dentes naturais e os artificiais. Así, pódese concluír que TrueTooth® serve como unha réplica adecuada con potencial aplicación no adestramento endodóntico. 3. Pódese concluír que o protocolo de eliminación de material de apoio descrito é efectivo para eliminar o material de apoio dos conductos radiculares dos dentes impresos en 3D. 4. A técnica PolyJet™ é adecuada para producir dentes impresos en 3D.
5. Os dentes impresos en 3D producidos con High Temperature RGD525™ teñen un comportamento similar á preparación endodóntica que o dente natural, e os dentes impresos en 3D pódense usar ao comparar dous sistemas de preparación. Os dentes impresos en 3D teñen o potencial de converterse no patrón de ouro en estudos ex vivo e adestramento endodóntico, substituíndo aos dentes naturais. Non obstante, para conseguir isto require máis investigación para abordar as limitacións actuais dos dentes impresos en 3D. Ademais, é necesario realizar esforzos concertados para establecer protocolos sólidos, facilitando a estandarización de métodos e permitindo a comparación de resultados entre os estudos.
RESUMEN Históricamente, los estudios ex vivo y los cursos preclínicos han favorecido el uso de dientes humanos extraídos, a menudo estimados como el punto de referencia (Bitter et al., 2016; De-Deus et al., 2020; Decurcio et al., 2019; Dobros et al., 2022; Hulsmann, 2022; Reymus et al., 2019) por su capacidad para imitar de cerca las condiciones clínicas, aunque la base empírica de esta afirmación sigue sin demostrarse (Choi et al., 2021). No obstante, el empleo de dientes humanos ofrece un medio valioso para reproducir escenarios clínicos y proporciona a los estudiantes una visión de la anatomía interna, junto con la experiencia táctil de la manipulación de la dentina (Gancedo-Caravia et al., 2020). Sin embargo, la extracción de dientes humanos presenta varios inconvenientes, como la dificultad de la recolección, las preocupaciones éticas, los riesgos potenciales de infección cruzada, las limitaciones de almacenamiento y los problemas relacionados con la estandarización (Al-Sudani & Basudan, 2017; De-Deus, 2012; Holden & Dracopoulos, 2017; Hulsmann, 2022; Reymus et al., 2019; Reymus et al., 2020). Los dientes artificiales que reproducen los dientes naturales pueden obviar estos inconvenientes (Al-Sudani & Basudan, 2017; Dobros et al., 2022; Reymus et al., 2021; Reymus et al., 2020). En los últimos años, el mercado ha visto la aparición de varios modelos fabricados en fábrica que presumen de realismo y estandarización. Sin embargo, hay que tener en cuenta su elevado coste, las limitadas opciones de dientes, los largos plazos de entrega y la dependencia de un fabricante concreto, además de que presentan discrepancias sustanciales tanto en los métodos de fabricación como en los materiales de las distintas marcas comerciales (Hulsmann, 2022; Reymus et al., 2019; Reymus et al., 2020; Yekta-Michael et al., 2021). Numerosos estudios emplean dientes impresos en 3D; sin embargo, el establecimiento de protocolos estandarizados sigue siendo crucial. Persisten variaciones metodológicas significativas entre estos estudios, lo que subraya la necesidad de esfuerzos de estandarización cohesivos (Decurcio et al., 2019; Hulsmann, 2022). El principal objetivo de emplear dientes impresos en 3D es lograr la estandarización. Para los investigadores, esto crea la posibilidad de establecer protocolos iguales y coherentes para los estudios ex vivo, permitiendo la comparación directa de los resultados. Teniendo en cuenta que su anatomía interna debe parecerse mucho a la de los dientes naturales originales, su comportamiento ante la preparación debe imitar al de los dientes naturales y deben ser capaces de evaluar y demostrar eficazmente las diferencias entre dos sistemas de preparación, también debe ser posible imprimir estos dientes a gran escala, rápidamente y a un coste mínimo. Por lo tanto, para lograr el grado necesario de normalización y el establecimiento de protocolos, es imprescindible abordar los problemas asociados a los dientes impresos en 3D.
Se ha informado de la dificultad de retirar el material de soporte de piezas con detalles intrincados, lo que puede dar lugar a un relleno parcial o completo de los canales (Fahad et al., 2013; Hulsmann, 2022; Orel et al., 2021; Reymus et al., 2019). Por lo tanto, existe la necesidad de investigar la influencia del material de soporte en la acción de la lima y sus efectos potenciales sobre las variables de interés. El desarrollo y validación de un protocolo, para la eliminación completa del material de soporte de los dientes impresos en 3D. Posteriormente, es esencial evaluar la consistencia y precisión de la técnica de impresión mediante la comparación de la anatomía interna de los dientes naturales con los dientes impresos en 3D utilizando micro-CT. Los objetivos principales de la presente tesis fueron: 1. Evaluar el impacto del material de soporte de la réplica TrueTooth® (DELabs), en la técnica de preparación y sus efectos potenciales en la evaluación del aumento de volumen utilizando escáneres micro-CT. 2. Desarrollar y validar un protocolo para la eliminación completa del material de soporte de los dientes impresos en 3D y evaluar su eficacia mediante la comparación de la anatomía interna de un diente natural con dientes impresos en 3D utilizando escáneres micro-CT. Además, la presente tesis también tiene como objetivos secundarios: 1. Evaluar el tiempo y el número de movimientos de picoteo necesarios para la preparación del conducto radicular utilizando el sistema ProTaper Gold® (Dentsply- Sirona), en TrueTooth® (DELabs) en comparación con los dientes naturales. 2. Evaluar el comportamiento del diente natural en comparación con los dientes impresos en 3D, con respecto a la preparación con ProTaper Gold® (Dentsply-Sirona) hasta la lima F2. Comparando aumento de volumen, volumen de dentina eliminada, centroides, transporte, zonas no preparadas mediante escaneos micro-CT. 3. Evaluar el tiempo y número de movimientos de picoteo necesarios para la preparación del conducto radicular mediante el sistema ProTaper Gold® (Dentsply-Sirona) en diente natural frente a dientes impresos en 3D. 4. Evaluar el comportamiento de dientes impresos en 3D frente a la preparación con ProTaper Gold® (Dentsply-Sirona) hasta la lima F2 y Endogal® (Endogal, Galician Endodontics Company) hasta la lima D. Comparando aumento de volumen, volumen de dentina eliminada, centroides, transporte, zonas no preparadas mediante escaneos micro- CT. 5. Evaluar el tiempo y número de movimientos de picoteo necesarios para la preparación del conducto radicular en dientes impresos en 3D utilizando el sistema ProTaper Gold® (Dentsply-Sirona) comparado con el sistema Endogal® (Endogal, Galician Endodontics Company). Para el primer objetivo primario, se utilizaron dientes naturales que cumplieran los criterios de inclusión, dientes con ápices completamente formados, ausencia de fracturas
radiculares, ausencia de signos de reabsorción externa e interna o tejido cariado en la región de interés, ausencia de tratamiento endodóntico previo, ausencia de calcificaciones, presencia de conductos y forámenes apicales separados, y un grado de curvatura que oscilara entre 20° y 50°. El grado de curvatura se evaluó mediante el método de Schneider (Schneider, 1971), y de acuerdo con estos criterios, y para economizar la asignación de recursos, se seleccionaron los conductos bucales de 7 molares maxilares. Asimismo, se utilizaron catorce réplicas TrueTooth® (DELabs) (#15- 001). La réplica TrueTooth® #15-001 es un molar maxilar con un conducto distobucal con una curvatura severa y un gran conducto mesiobucal, en forma de cinta, con una curvatura moderada; estas características son adecuadas para los fines del presente estudio. Los 14 conductos mesiobucales se utilizaron para evaluar el efecto del material de soporte, mientras que los conductos distobucales sirvieron para compararlos con los 14 conductos bucales naturales. Los dos grupos fueron escaneados mediante micro-CT antes de la preparación y después de la preparación con el sistema ProTaper Gold® (Dentsply-Sirona) hasta una lima F2. Después de la preparación se realizaron escaneos micro-CT y se evaluó el aumento de volumen, también se registró el número de movimientos de picoteo necesarios para que cada lima alcanzara la longitud de trabajo y la duración de la rotación de la lima dentro del conducto hasta alcanzar la longitud de trabajo. Para el segundo objetivo primario, de un grupo de catorce molares maxilares, previamente escaneados mediante micro-CT, se eligió un segundo molar maxilar izquierdo con tres raíces completamente separadas, cada una de las cuales presentaba un único conducto independiente sin conductos laterales. La raíz mesiobucal presentaba un conducto ovalado, mientras que la raíz distobucal presentaba un conducto redondo de pequeño diámetro y la raíz palatina presentaba un conducto redondo de gran diámetro. El archivo STL se imprimió utilizando la tecnología PolyJet™ con una impresora Stratasys Object30 Prime™ (Stratasys Ltd), en modo de Alta Calidad que presentaba un grosor de capa de 16 µm. High Temperature RGD525™ (Stratasys Ltd) fue el material de impresión elegido, junto con SUP706B™ (Stratasys Ltd) como material de soporte. Una vez realizado el protocolo de eliminación del material de soporte, se escanearon por micro- CT veinte dientes impresos en 3D antes de la preparación y, a continuación, se asignaron aleatoriamente en dos grupos (n=10). Un grupo y el diente natural se prepararon con ProTaper Gold® (Dentsply-Sirona), el otro grupo con Endogal® (Endogal, Galician Endodontics Company). Después de la preparación se realizaron escaneos micro-CT, y se compararon el aumento de volumen, el volumen de dentina eliminada, los centroides, el transporte y las zonas no preparadas; también se registraron el número de movimientos de picoteo necesarios para que cada lima alcanzara la longitud de trabajo y la duración de la rotación de la lima dentro del conducto hasta alcanzar la longitud de trabajo. En los resultados relativos al primer objetivo primario, los valores medios de aumento de volumen fueron negativos, respectivamente -1,32 mm3 y -17,66%. El tiempo necesario para la preparación de los dientes naturales fue ligeramente superior al de los dientes artificiales, con 64,3 segundos frente a 63,5 segundos. Sin embargo, no se observaron diferencias estadísticamente significativas entre los dientes naturales y los artificiales en cuanto al tiempo total de preparación (p > 0.05), o para cada lima individual (p > 0.05).
El número de movimientos de picoteo necesarios para la preparación de los dientes naturales fue superior al de los dientes artificiales, con 33,5 movimientos frente a 25,86 movimientos. Sin embargo, no se observaron diferencias estadísticamente significativas entre los dientes naturales y los artificiales en cuanto al número total de movimientos de picoteo (p > 0.05), o para cada lima individual (p > 0.05). En cuanto a los resultados asociados al segundo objetivo primario, no hubo diferencias estadísticamente significativas entre el diente natural y los dientes impresos en 3D para todas las variables (p > 0.05), siendo estas variables, el volumen del canal, el centroide X, Y, Z antes de la preparación tanto para el diente natural como para los dientes impresos en 3D, y el porcentaje de expansión del volumen del diente para los dientes impresos en 3D, evaluados mediante escáneres Micro-CT. Estos resultados pretendían evaluar la eficacia del protocolo de eliminación del material de soporte. Los dientes impresos en 3D mostraron un comportamiento similar al diente natural después de la preparación, ya que no hubo diferencias estadísticamente significativas (p > 0.05), relacionadas con las mediciones del volumen del canal, centroide X, Y, Z después de la preparación, y con el volumen de dentina eliminada, porcentaje de aumento de volumen, alteración del centroide X, Y, Z, transporte y porcentaje de áreas no preparadas. El tiempo necesario para la preparación del diente natural fue ligeramente superior en comparación con los dientes impresos en 3D, con 179 segundos frente a 177 segundos. Sin embargo, no se observaron diferencias estadísticamente significativas entre el diente natural y los dientes impresos en 3D en cuanto al tiempo total de preparación( p > 0.05), o para cada lima individual(p > 0.05). El número de movimientos de picoteo necesarios para la preparación del diente natural fue mayor en comparación con los dientes impresos en 3D, con 102 movimientos frente a 93 movimientos. Sin embargo, no se observaron diferencias estadísticamente significativas entre el diente natural y los dientes impresos en 3D en cuanto al número total de movimientos de picoteo (p > 0.05), o para cada lima individual (p > 0.05). En cuanto al aumento de volumen, volumen de dentina removida, centroides, transporte, zonas no preparadas evaluadas mediante micro-CT, y el tiempo de preparación y número de movimientos de picoteo requeridos para la preparación del conducto radicular, tanto para los sistemas ProTaper Gold® (Dentsply Sirona) como Endogal® (Endogal, Galician Endodontics Company), junto con el tiempo y número de movimientos de picoteo requeridos para cada lima de cada sistema. No se observaron diferencias estadísticamente significativas para todas las variables antes de la preparación (p > 0.05). Ambos sistemas mostraron un comportamiento similar, como indica la ausencia de diferencias estadísticamente significativas (p > 0.05) en las mediciones del volumen del conducto, centroide X, Y, Z tras la preparación, volumen de dentina eliminada, porcentaje de aumento de volumen, alteración del centroide X, Y, Z, transporte y porcentaje de zonas no preparadas. Sin embargo, el sistema ProTaper Gold® (Dentsply Sirona) demostró un mayor porcentaje de aumento de volumen y un menor porcentaje de zonas no tocadas, con un 47,68% y un 54,97%, respectivamente, en comparación con el sistema Endogal® (Endogal, Galician Endodontics Company), que mostró unos porcentajes del 45,02% y el 56,41%, respectivamente.
El tiempo necesario para la preparación con el sistema ProTaper Gold® (Dentsply Sirona) fue superior en comparación con el sistema Endogal® (Endogal, Galician Endodontics Company) con 177 segundos frente a 111,6 segundos. Se observaron diferencias estadísticamente significativas entre los dos sistemas en cuanto al tiempo total de preparación (p < 0.05). Además, se observaron diferencias estadísticamente significativas entre la lima ProGlyder® (Dentsply Sirona) y la lima A (Endogal, Galician Endodontics Company) (p < 0.05). El número de movimientos de picoteo necesarios para la preparación con el sistema ProTaper Gold® (Dentsply Sirona) fue mayor en comparación con el sistema Endogal® (Endogal, Galician Endodontics Company) con 93 movimientos frente a 47,40 movimientos. Se observaron diferencias estadísticamente significativas entre ambos sistemas en cuanto al número de movimientos de picoteo (p < 0.05). Además, se observaron diferencias estadísticamente significativas entre la lima ProGlyder® (Dentsply Sirona) y la lima A (Endogal, Galician Endodontics Company) (p < 0.05). El primer objetivo principal de este estudio era evaluar cómo influye el material de soporte de la réplica TrueTooth® (DELabs) en la técnica de preparación y su posible repercusión en los cambios de volumen evaluados mediante escáneres de micro-CT. Los resultados revelaron un valor medio negativo para el aumento de volumen del conducto radicular tras la preparación en el conducto mesiobucal, lo que indica una pérdida de volumen tras la preparación, que parece absurda. También se confirmó con el conducto distobucal que, aunque tenía un valor medio positivo, seguía presentando valores negativos en algunas muestras para el aumento de volumen. En consecuencia, es evidente que el material de soporte afecta significativamente al análisis 3D. Por lo tanto, se rechaza la hipótesis nula. La densidad del material de soporte tras la preparación superó la densidad previa a la preparación y se aproximó a la de la resina que compone la raíz. Por consiguiente, tras la preparación del conducto, el software de análisis 3D ya no distingue estos materiales como entidades separadas, mientras que dicha diferenciación era factible antes de la preparación. El objetivo secundario era evaluar el tiempo y el número de movimientos de picoteo necesarios para la preparación del conducto radicular utilizando el sistema ProTaper Gold® (Dentsply-Sirona), sobre TrueTooth® (DELabs) en comparación con los dientes naturales. El tiempo medio de preparación de los dientes artificiales fue un segundo inferior y se necesitaron menos movimientos de picoteo para la preparación del conducto en comparación con los dientes naturales. Sin embargo, no hubo diferencias estadísticamente significativas entre ellos. Por lo tanto, se aceptó la hipótesis nula. Estos resultados sugieren que, a pesar de que los dientes artificiales requieren menos tiempo y menos movimientos de picoteo para la preparación, posiblemente debido a las variaciones de dureza entre la resina y la dentina humana (Al-Sudani & Basudan, 2017; Hulsmann, 2022; Reymus et al., 2020). Los resultados de la presente investigación en relación con el tiempo de preparación y el número de movimientos de picoteo necesarios para la preparación del conducto radicular sugieren que TrueTooth® (DELabs) es prometedor para la formación en endodoncia. No obstante, en el futuro serán necesarias nuevas investigaciones que empleen distintos
sistemas de preparación, geometrías diversas y movimientos de preparación cinemáticos diferentes. El segundo objetivo principal era describir un protocolo de eliminación del material de soporte y comparar la anatomía del conducto radicular entre un diente natural y un diente impreso en 3D utilizando escáneres Micro-CT del diente natural como referencia. La Micro-CT, reconocida por su naturaleza no invasiva y no destructiva, permite la evaluación de varios parámetros tanto antes como después de la preparación. Está ampliamente considerado como el patrón oro en la investigación de la preparación del conducto radicular (Hulsmann, 2022). Al comparar el volumen y los centroides X, Y, Z del diente natural con los de los dientes impresos en 3D antes de la preparación, nuestros resultados no revelaron diferencias estadísticamente significativas entre ellos. En consecuencia, se aceptó la hipótesis nula. Estos resultados indican que el protocolo de eliminación de material de soporte descrito es eficaz para eliminar el material de soporte (SUP706B™) utilizado en este estudio, y PolyJet® es adecuado para producir dientes impresos en 3D con una anatomía interna similar a la de los dientes naturales. Para que los dientes impresos en 3D puedan ser utilizados en estudios de preparación ex vivo, su comportamiento ante la preparación debe ser similar al diente natural, los presentes resultados en cuanto a volumen de dentina eliminada, porcentaje de aumento de volumen, transporte, y áreas no preparadas, muestran que no hubo diferencias estadísticamente significativas entre ellos. Por lo tanto, se aceptó la hipótesis nula, llegando a la conclusión de que los dientes impresos en 3D se comportan de forma similar al diente natural cuando se preparan con ProTaper Gold® (Dentsply-Sirona). El tiempo y el número de movimientos de picoteo necesarios para la preparación del conducto radicular mediante el sistema ProTaper Gold® (Dentsply-Sirona) en diente natural en comparación con los dientes impresos en 3D, muestran que los dientes impresos en 3D requirieron menos tiempo de preparación y menos movimientos de picoteo. Sin embargo, no hubo diferencias estadísticamente significativas entre ellos. Por lo tanto, se aceptó la hipótesis nula, reforzando la conclusión del primer objetivo secundario, que los dientes impresos en 3D se comportan de forma similar al diente natural cuando se preparan con ProTaper Gold® (Dentsply-Sirona). Evaluar el comportamiento de los dientes impresos en 3D a la preparación con ProTaper Gold® (Dentsply-Sirona) hasta la lima F2 y Endogal® (Endogal, Galician Endodontics Company) hasta la lima D. Para ello se comparó el aumento de volumen, el volumen de dentina eliminada, los centroides, el transporte y las zonas no preparadas mediante escáner micro-CT. Los resultados de volumen de dentina removida, porcentaje de aumento de volumen, transporte y áreas no preparadas, muestran que no hubo diferencias estadísticamente significativas entre los dos sistemas de preparación. Así pues, se aceptó la hipótesis nula. Sin embargo, al examinar los resultados individualmente, se hace evidente que Endogal® (Endogal, Galician Endodontics Company) produjo un menor aumento de volumen y eliminación de dentina, junto con un mayor porcentaje de zonas no preparadas. A pesar de que ambos sistemas tienen el mismo tamaño apical para la preparación, las variaciones en la conicidad y el diseño de la sección transversal podrían explicar estas diferencias.
Las diferencias en la preparación del conducto radicular también están asociadas a las dimensiones de las limas utilizadas (Chan et al., 2023; Silva et al., 2020). Para evaluar el tiempo y el número de movimientos de picoteo necesarios para la preparación del conducto radicular en dientes impresos en 3D utilizando el sistema ProTaper Gold® (Dentsply-Sirona) en comparación con el sistema Endogal® (Endogal, Galician Endodontics Company), se observaron diferencias estadísticamente significativas entre ambos, siendo el Endogal® (Endogal, Galician Endodontics Company) más rápido y requiriendo menos movimientos de picoteo. De esta forma rechazamos la hipótesis nula. Sin embargo, estos resultados son sencillos de interpretar y esperados, ya que el sistema Endogal® (Endogal, Galician Endodontics Company) utiliza una lima menos en comparación con el sistema ProTaper Gold® (Dentsply-Sirona). También se observaron diferencias estadísticamente significativas entre la lima ProGlyder® (Dentsply Sirona) y la lima A (Endogal, Galician Endodontics Company). El tiempo de preparación registrado fue de 27,30 segundos para la lima ProGlyder® (Dentsply Sirona) y de 6,90 segundos para la lima A (Endogal, Galician Endodontics Company), mientras que los movimientos de picoteo fueron de 14,70 y 5,10 respectivamente. La lima ProGlyder® (Dentsply Sirona) se caracteriza por un tamaño de punta de 0,16 mm y una conicidad variable que oscila entre el 2% y el 8,5%(Alovisi et al., 2017; Gambarini et al., 2021; Keskin et al., 2020; Kirchhoff et al., 2015; Paleker & van der Vyver, 2017). Por el contrario, la lima A (Endogal, Galician Endodontics Company) mantiene una conicidad constante del 3% con un tamaño de punta de 0,15 mm (Castelo-Baz et al., 2023; Endogal; Faus-Matoses et al., 2022; Ruiz-Pinon et al., 2021). Aunque ambas limas comparten un tamaño apical similar, las diferencias en la conicidad y el diseño de la sección transversal pueden explicar estas distinciones. Como se dijo anteriormente, los protocolos para la estandarización de los estudios que utilizan dientes impresos en 3D todavía tienen que ser desarrollados (Hulsmann, 2022), nuestros resultados dentro de sus limitaciones presenta una descripción de un protocolo eficaz para la eliminación de material de soporte SUP706B™, demuestran que los dientes impresos en 3D impresos con material de Alta Temperatura RGD525™ tienen un comportamiento similar a la preparación endodóntica que los dientes naturales. Sin embargo, es necesario investigar en el futuro para estandarizar los estudios con dientes impresos en 3D. Esto implica determinar la orientación óptima en el lecho de la impresora para dientes con múltiples raíces, decidir el nivel de simplificación del archivo STL sin sacrificar información, evaluar la eficacia del protocolo de eliminación del material de soporte para diversas morfologías radiculares y comprender cómo las variaciones en las rpm, el par de torsión, la amplitud de los movimientos de picoteo y el diseño de la lima pueden afectar a la preparación de los dientes impresos en 3D. En la secuencia de estos resultados, se puede concluir que: 1. En el análisis 3D del conducto mesiobucal de los dientes artificiales, el aumento medio del volumen del conducto radicular resultó negativo, lo que indica que el material de soporte influyó en el análisis 3D del Micro-CT de la variable considerada.
2. No se encontraron diferencias estadísticamente significativas en el tiempo y el número de movimientos de picoteo entre los dientes naturales y los dientes artificiales. Por lo tanto, se puede concluir que TrueTooth® sirve como una réplica adecuada con potencial aplicación en la formación endodóntica. 3. Se puede concluir que el protocolo de eliminación del material de soporte descrito es eficaz para eliminar el material de soporte de los conductos radiculares de los dientes impresos en 3D. 4. La técnica PolyJet™ es adecuada para producir dientes impresos en 3D. 5. Los dientes impresos en 3D producidos con RGD525™ de alta temperatura tienen un comportamiento similar a la preparación endodóntica que el diente natural, y los dientes impresos en 3D pueden utilizarse cuando se comparan dos sistemas de preparación. Existe el potencial para que los dientes impresos en 3D establezcan un nuevo estándar en los estudios ex vivo y en la formación endodóntica, suplantando potencialmente a los dientes naturales. Sin embargo, para conseguirlo es necesario seguir investigando para abordar las limitaciones actuales de los dientes impresos en 3D. Además, se necesitan esfuerzos concertados para establecer protocolos robustos, que faciliten la estandarización de métodos y permitan la comparación de resultados entre estudios.
printed teeth printed with High Temperature RGD525™ material have similar behaviour to endodontic preparation that natural teeth. However, future research is necessary to standardize studies involving 3D printed teeth. This entails determining the optimal orientation on the printer bed for multi-rooted teeth, deciding the level of simplification for the STL file without sacrificing information, assessing the effectiveness of support material removal protocol for various root morphologies, and understanding how variations in rpm, torque, amplitude of pecking movements, and file design can impact the preparation of 3D printed teeth. In the sequence of these results, it can be concluded that: 1. In the 3D analysis of the artificial teeth's mesiobuccal canal, the average increase in root canal volume was found to be negative, indicating that the support material influenced the Micro-CT 3D analysis of the variable under consideration. 2. No statistically significant differences were found in the time and number of pecking movements between natural teeth and artificial teeth. Thus, it can be concluded that TrueTooth® serves as a suitable replica with potential application in endodontic training. 3. The described support material removal protocol can be concluded as effective in eliminating the support material from 3D printed teeth root canals. 4. The PolyJet™ technique is suitable for producing 3D printed teeth. 5. 3D printed teeth produced with High Temperature RGD525™ have similar behaviour to endodontic preparation that natural tooth, and 3D printed teeth can be used when comparing two preparation systems. The potential exists for 3D printed teeth to establish a new standard in ex vivo studies and endodontic training, potentially supplanting natural teeth. However, achieving this requires further research to address the current limitations of 3D printed teeth. Additionally, there is a need for concerted efforts to establish robust protocols, facilitating method standardization and enabling comparison of results across studies.
ABBREVIATIONS 3D – Three Dimensions NiTi – Nickel-Titanium nm – Nanometres mm – Millimeters mm3 – Cubic Millimeters º – Degrees % – Percentage Micro-CT – Micro Computed Tomography µm – Micrometres 2D – Two Dimensions CBCT – Cone Beam Computed Tomography KV – Kilovolt mA – Microampere ms – milliseconds Mbytes – Megabytes ml – millilitres MPa – MegaPascal
INDEX INDEX 1. INTRODUCTION .................................................................................................... 37 1.1 ENDODONTICS: DEFINITION AND OBJECTIVES ...................................... 37 1.2 NiTi ALLOY ........................................................................................................... 38 1.3 ENDODONTIC FILES DESIGN .......................................................................... 39 1.3.1 ProTaper Gold® system 41 1.3.2 Endogal® system 42 1.4 MICRO COMPUTED TOMOGRAPHY ............................................................. 42 1.4.1 Micro-CT procedure 44 1.4.1.1 Sample preparation ...................................................................................... 44 1.4.1.2 Establishing scan parameters ....................................................................... 44 1.4.1.3 Scanning procedure ...................................................................................... 44 1.4.1.4 3D reconstruction of the scan ...................................................................... 45 1.4.1.5 Processing reconstructed volume ................................................................. 45 1.5 THREEDIMENSIONAL PRINTED TEETH ................................................... 46 1.5.1. Why 3D printed teeth are needed for endodontics’s science and teaching community 46 1.5.2 How 3D printed teeth are manufactured 49 1.5.3 Problems with 3D printed teeth 52 2. JUSTIFICATION AND AIMS ................................................................................ 57 2.1 JUSTIFICATION ................................................................................................... 57 2.2 AIMS ........................................................................................................................ 58 2.2.1 First primary aim 58 2.2.1.1 Secondary aims ............................................................................................ 58 2.2.2 Second primary aim 58 2.2.2.1 Secondary aims ............................................................................................ 58 3. HYPOTHESIS .......................................................................................................... 60 3.1 HYPOTHESIS OF FIRST PRIMARY AIM ...................................................... 60 3.1.1 Hypothesis of secondary aim 60 3.2 HYPOTHESIS OF SECOND PRIMARY AIM ................................................. 60 3.2.1 Hypothesis of secondary aims ...................................................................... 60 4. MATERIALS AND METHODS ............................................................................. 62 4.1 MATERIAL AND METHODS FOR FIRST PRIMARY AIM ......................... 62 4.1.1 Natural teeth selection 62 4.1.2 Artificial specimen selection 63
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 4.1.3 Initial micro-CT scanning 63 4.1.4 Root Canal Preparation 63 4.1.5 Micro-CT analysis 64 4.1.6 Total preparation time 64 4.1.7 Total number of pecking movements 64 4.2 MATERIAL AND METHODS FOR SECOND PRIMARY AIM .................... 64 4.2.1 Natural tooth selection 64 4.2.2 3D printing process and support material removal protocol 66 4.2.3 3D printed teeth initial micro-CT scanning 68 4.2.4 Root canal preparation 68 4.2.4.1 Preparation of natural tooth and group I with ProTaper Gold® .................. 69 4.2.4.2 Preparation of group II with Endogal® ....................................................... 69 4.2.5 Micro-CT analysis 70 4.2.6 Total preparation time 70 4.2.7 Total number of pecking movements 70 4.3 STATISTICAL ANALYSIS .................................................................................. 70 5. RESULTS .................................................................................................................. 72 5.1 RESULTS OF FIRST PRIMARY AIM ............................................................... 72 5.2 RESULTS OF SECOND PRIMARY AIM .......................................................... 76 6. DISCUSSION ............................................................................................................ 84 6.1 DISCUSSION OF FIRST PRIMARY AIM ......................................................... 84 6.2 DISCUSSION OF SECOND PRIMARY AIM .................................................... 86 7. CONCLUSIONS ....................................................................................................... 93 8. BIBLIOGRAPHY ..................................................................................................... 95 9. FIGURES INDEX .................................................................................................. 114 10. TABLES INDEX .................................................................................................. 116 11. APPENDICES ....................................................................................................... 118 APPENDIX 1 - APPROVAL BY THE ETHICS COMMITTEE OF INSTITUTO ASTURIANO DE ODONTOLOGIA OF OVIEDO UNIVERSITY (IAO-23-0104) ...................................................................................................................................... 118 APPENDIX 2 - APPROVAL BY THE ETHICS COMMITTEE OF FERNANDO PESSOA UNIVERSITY (FCS/PI 429/23) ................................................................ 119 APPENDIX 3 – PERMISSION TO REPRODUCE PAPER .................................. 121
INDEX APPENDIX 4 – PERMISSION TO REPRODUCE PAPER .................................. 135 APPENDIX 5 – PERMISSION TO REPRODUCE PAPER .................................. 147
1. INTRODUCTION A section of this chapter has already been published as: Reis, T., et al., 3D-Printed Teeth in Endodontics: Why, How, Problems and Future-A Narrative Review. Int J Environ Res Public Health, 2022. 19(13). https://doi.org/10.3390/ijerph19137966
INTRODUCTION 37 1. INTRODUCTION 1.1 ENDODONTICS: DEFINITION AND OBJECTIVES Endodontics includes the study and practice within dentistry focused on the structure, function, and diseases of the dental pulp and surrounding tissues. It delves into both fundamental and clinical sciences, exploring the biology of healthy pulp as well as the causes, diagnosis, prevention, and treatment of pulp-related injuries and associated conditions in the periradicular region (AAE, 2020). Bacteria serve as the primary instigator of pulpal and periapical pathologies. Consequently, all endodontic procedures are directed towards eradicating both pulp tissue and as many bacteria as feasible (Liang et al., 2018; Ordinola-Zapata et al., 2014). According to the European Society of Endodontology, “the objectives of root canal system preparation are to: remove remaining pulp tissue, eliminate microorganisms, remove debris and shape the root canal system in order to be cleaned and filled” (ESE, 2006) . The American Association of Endodontists defines root canal preparation as “Procedures involved in cleaning and shaping the canal system prior to obturation”, distinguishing between “biomechanical preparation” as the “use of rotary/reciprocating and/or hand files to expose, clean, enlarge and shape the pulp canal space, usually in conjunction with irrigants” and “chemomechanical preparation” as the “use of chemicals for irrigation of the root canal, demineralization of dentin, dissolution of pulp tissue and neutralization of bacterial products and toxins; used in conjunction with biomechanical preparation” (AAE, 2020). The mechanical preparation of the root canal system stands as a pivotal stage in endodontics, as it dictates the effectiveness of all subsequent procedures that follow (Sinibaldi et al., 2012; Stavileci et al., 2013). The criteria for a well-prepared root canal involve preserving the original anatomy and the apical constriction, while ensuring a gradual tapering from the crown to the apex (Arias & Peters, 2022; ESE, 2006). In pursuit of these objectives, a diverse array of manual rotary files has been introduced. The evolution in manufacturing techniques has resulted in a wide range of endodontic files, varying in design, alloys, and movement types (Alberton et al., 2020; Duque et al., 2017; Duque et al., 2019; Elashiry et al., 2020; Fernandes et al., 2020; Ordinola-Zapata et al., 2014). Comprehensive understanding of the shaping characteristics and efficacy of rotary or reciprocating files is indispensable in aiding clinicians to choose the suitable system for diverse clinical scenarios. Given the continual introduction of new preparation systems into the market (Kirchhoff et al., 2015; Nagendrababu & Ahmed, 2019), clinicians rely on impartial evaluations of their features to inform their clinical decision-making process (Duque et al., 2017; Gagliardi et al., 2015; Pinheiro et al., 2018). Presently, there are over
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 38 200 NiTi preparation systems available in the market, yet the scientific validation of their clinical safety and efficiency remains largely unconfirmed (Aksoy et al., 2021; Arias & Peters, 2022). Over recent decades, there have been notable shifts in root canal preparation protocols, with the emergence of numerous new nickel-titanium systems. These systems offer enhanced flexibility and resistance to torsion, leading to reduced working time, operator fatigue, and the likelihood of procedural mishaps. Nevertheless, clinicians still necessitate understanding the shaping properties and performance assessment of these systems to effectively match them with clinical cases (Nagendrababu & Ahmed, 2019; Pinheiro et al., 2018; Sousa-Neto et al., 2018). Nickel-titanium (NiTi) files were initially introduced to the market in the 1990s, and since then, approximately 1280 studies have been published in PubMed-indexed journals. Previous bibliometric reviews have identified 'instrumentation' as the most frequently used term in titles and among the top-cited articles in endodontics. This collective information sheds light on root canal preparation emerging as the most cited keyword extracted from selected studies. These ex-vivo studies on root canal preparation offer valuable insights, aiding in the enhancement of biological outcomes. Hence, the continuation of such research efforts in the future remains essential (Aksoy et al., 2021; Arias & Peters, 2022; Hulsmann, 2022; Ordinola-Zapata et al., 2020; Yilmaz et al., 2019). Key research areas in root canal preparation include dentin removal and volume expansion; straightening and transportation; unprepared root canal regions; and working time (Gancedo-Caravia et al., 2020; Hülsmann et al., 2005). 1.2 NiTi ALLOY The NiTi alloy, coined "nitinol" from nickel (Ni), titanium (Ti), and Naval Ordnance Laboratory (NOL), originated from the United States space program and was formulated at the Naval Ordnance Laboratory in 1963. Renowned for its superelasticity, shapememory effect, and biocompatibility, this alloy found application in orthodontic wire production as early as 1971 (Liang & Yue, 2022; Zupanc et al., 2018). The equiatomic NiTi alloy consists of approximately equal proportions of nickel and titanium atoms (55% Ni and 45% Ti) and is characterized by three microstructural phases: austenite, martensite, and the R-phase. Austenite serves as the parent phase at elevated temperatures, while martensite acts as the daughter phase at lower temperatures, both constituting primary crystal structures of the NiTi alloy. Temperature and stress can induce alterations in the lattice crystal structure. Under normal conditions, the conventional NiTi alloy primarily adopts the austenitic form. However, within a narrow temperature range, a rhombohedrally distorted phase, known as the R-phase, may emerge, displaying a lower Young’s modulus compared to austenite and martensite. The R-phase NiTi alloy exhibits flexibility. Upon heating, martensite can transition back to austenite. In its austenitic state, the NiTi alloy demonstrates rigidity with shape memory properties, whereas in the martensitic phase, it becomes flexible, ductile, and easily deformable (Arias & Peters, 2022; Dablanca-Blanco et al., 2022; Hieawy et al., 2015; Liang & Yue, 2022; Peters et al., 2017; Tabassum et al., 2019; Thompson, 2000; Zanza et al., 2021; Zanza et al., 2022; Zupanc et al., 2018).
INTRODUCTION 39 The phase composition and mechanical characteristics of the NiTi alloy are contingent upon the surrounding temperature and whether the alloy is subjected to cooling or heating processes. When the temperature surpasses the austenite finish temperature, the alloy assumes an austenitic state, exhibiting stiffness, hardness, and exceptional superelastic properties. Conversely, when the temperature falls below the martensite finish temperature, the NiTi alloy adopts a martensitic state, characterized by softness, ductility, ease of deformation, and the manifestation of the shape memory effect. Significant improvement in the mechanical properties of NiTi instruments have been attained through minor adjustments to the proportion of its constituent elements, however modifying the transformation temperatures of the NiTi alloy in use, which can be accomplished through thermal and mechanical treatments or adjustments in chemical composition, stands as the principal method for manufacturers to adjust the phase composition and, consequently, the mechanical characteristics of the NiTi alloy (Alqedairi et al., 2019; Arias & Peters, 2022; Dablanca-Blanco et al., 2022; Grande et al., 2017; Liang & Yue, 2022; Peters et al., 2017; Tabassum et al., 2019; Thompson, 2000; Zanza et al., 2022; Zupanc et al., 2018). During clinical application, traditional NiTi alloy remains in the austenitic phase, whereas thermomechanical treated NiTi alloys exhibit varying proportions in the R-phase and martensitic phase. Such alterations result in endodontic files that are notably more flexible and possess enhanced fracture resistance. Over the years, numerous alloys have been developed through the heat treatment of NiTi (Arias & Peters, 2022; Thompson, 2000; Zanza et al., 2021). In 2010, the market saw the introduction of NiTi control memory wire, featuring a reduced nickel content (52%) compared to conventional NiTi alloys (with nickel content ranging from 54.5% to 57%), leading to enhanced mechanical properties. Through postmanufacturing heat treatments, the crystal structure of these wires is primarily martensitic at room temperature. As a result, control memory wires have evolved into alloys with regulated memory, improved fracture resistance, excellent flexibility, and resistance to cyclic fatigue. These wires can be prebent to conform to the curvature of the root canal. If the instrument undergoes deformation, such as uncoiling, during use, it can revert to its original shape upon heating, as in an autoclave, allowing for reuse, a phenomenon known as the controlled shape memory effect. Blue and gold wires are obtained when the control memory wire alloy undergoes repeated heat and cooling treatments, forming a titanium oxide layer on its surface, with the surface colour varying based on the thickness of this layer. A thickness of 60–80 nm results in a blue surface colour, while a thickness of 100– 140 nm yields a golden colour. This titanium oxide layer compensates for any hardness lost during the processing of the control memory wire alloy, thereby enhancing cutting efficiency and wear resistance (Arias & Peters, 2022; Dablanca-Blanco et al., 2022; Duque et al., 2019; Elnaghy & Elsaka, 2016; Liang & Yue, 2022; Tabassum et al., 2019; Zupanc et al., 2018). 1.3 ENDODONTIC FILES DESIGN NiTi rotary files appeared by 1990s, and one of the major advancements was the change related to file taper, compared with ISO-normed hand files with 0.02 taper. NiTi alloy flexibility made possible the increase of taper and still prepare curved canals in a safe manner. In contrast with stainless steel that follow a unified international standard, for the design of rotary NiTi files it has not been established. In this way, the geometric
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 40 design of rotary NiTi files has undergone continuous refinement to achieve an equilibrium between cutting effectiveness and safety. Endodontic companies persist in developing files that are both more efficient and safer. This advancement is achieved either through alterations in the mechanical properties of the NiTi alloy, as mentioned earlier, or through modifications in file design, encompassing aspects such as tip and taper design, the presence of radial lands, rake angles, helical angles, and pitch, as well as the type of movement kinematics (Alqedairi et al., 2019; Arias & Peters, 2022; Dablanca-Blanco et al., 2022; Grande et al., 2005; Liang & Yue, 2022; Sanghvi & Mistry, 2011; Silva et al., 2023). The tip of a file can be categorized into two types: cutting and non-cutting tips. The design of the tip significantly influences the file's ability to navigate obstacles within the canal and its likelihood of causing clinical damage. A file with a cutting tip is more effective in narrow canals due to its aggressive nature but poses greater risk when used in curved canals compared to a non-cutting tip (Grande et al., 2005; Peters et al., 2017; Sanghvi & Mistry, 2011). The taper refers to the ratio of an instrument's diameter to its length, representing the rate of diameter increase per millimeter along its working surface, from the tip towards the file handle. For instance, a 30-tip file with a taper of 0.2 would exhibit a diameter of 0.32 mm at 1 mm from the tip and 0.34 mm at 2 mm from the tip and so on. The taper can be constant or variable. There are two options for preparing a canal. Firstly, using files with a constant taper but with different tip sizes. Secondly, employing files with variable tapers on the same file or graduating tapers while maintaining the tip size. The idea behind the latter choice is that each subsequent file engages only a small portion of the canal wall. As a result, frictional resistance is reduced, leading to lower torque requirements for operation (Dablanca-Blanco et al., 2022; Liang & Yue, 2022; Sanghvi & Mistry, 2011). The radial land is a surface located directly behind the cutting edge. It aids the instrument's central movement within the root canal without inducing canal transportation. A broader radial land enhances the peripheral strength of the instrument, albeit at the cost of heightened friction during dentin cutting, requiring additional torque and time for effective operation during work (Dablanca-Blanco et al., 2022; Liang & Yue, 2022; Sanghvi & Mistry, 2011). The rake angle relates to the inclination and placement of the cutting edge on the crosssection in relation to the dentin surface and is defined as the angle created by the cutting edge and a cross-section taken perpendicular to the long axis of the instrument. The cutting angle can be either positive or negative. A positive rake angle design enables high cutting efficiency but results in rapid wear. An excessively positive rake angle may cause digging and gouging of the dentin, potentially resulting in instrument separation. Conversely, instruments with a neutral or negative rake angle primarily grind against the root canal wall, focusing more on scrapping than cutting, thus diminishing dentin cutting efficiency (Dablanca-Blanco et al., 2022; Grande et al., 2005; Ha et al., 2017; Liang & Yue, 2022; Sanghvi & Mistry, 2011). The helical angle refers to the angle formed between the cutting edge and the long axis of the file. As a rotary file operates within the canal, it is crucial to effectively remove dentinal debris. Files with a constant helical angle may accumulate debris and are more prone to screw in forces or the sensation of being pulled into the canal as the file rotates.
INTRODUCTION 47 Ethical concerns arise regarding the previous owners of natural teeth, as their consent for the use of their teeth as biomaterial should have been obtained (Dobros et al., 2022; Holden & Dracopoulos, 2017; Hulsmann, 2022). A troubling trend is the purchase of human teeth online, where pressures to acquire teeth may lead investigators and students to overlook inquiries into the origins and reasons behind the extraction of these teeth (Holden & Dracopoulos, 2017). Potential risks of cross-infection and storage: natural teeth are heavily contaminated, posing challenges for sterilization. Common disinfection methods like sodium hypochlorite and hydrogen peroxide are often ineffective (Hope et al., 2013; Kumar et al., 2005). Furthermore, sterilization and storage procedures may damage or alter teeth. Research indicates that autoclaving reduces teeth's resistance to fracture (Michaud et al., 2018). Similarly, the storage conditions affect tooth integrity, with teeth stored in water exhibiting higher resistance to fracture than those stored dry (Mello et al., 2020). Consequently, preparing natural teeth entails unpleasant tasks such as storing them in strong-smelling liquids (Kroger et al., 2017). Standardization poses a challenge due to the complex anatomy of the root canal system, resulting in difficulties in establishing well-balanced study groups and ensuring fair student evaluations (De-Deus, 2012; De-Deus et al., 2020; Orel et al., 2021; Reymus et al., 2019; Reymus et al., 2020; Versiani, Pecora, et al., 2013). Consequently, studies may reflect the impact of canal anatomy rather than the specific variable under investigation (De-Deus, 2012). Students often express concerns that anatomical variations hinder the validity of individual performance assessments (Tchorz et al., 2015). In ex vivo studies, the prevalent approach involves pairing tooth samples based on shared anatomical characteristics, including tooth type, root length, root anatomy, curvature degree and angle, and root canal diameter. In some cases, teeth are paired with contralateral teeth. Randomization methods, with or without the aid of radiographs, are also utilized to allocate teeth from the same group (De-Deus et al., 2020; Hulsmann, 2022; Johnsen et al., 2017; Johnsen et al., 2018; Xu et al., 2016). Recently, certain studies have begun utilizing specific anatomical parameters identified through micro-CT scanning (De-Deus et al., 2020; Hulsmann, 2022). De-Deus et al. (2020) conducted a comparison between the randomized method, radiographic method, and micro-CT method. The findings indicated that the micro-CT method offered superior control over confounding anatomical variances. However, this study commenced with a pool of 1708 single-rooted mandibular incisors. From this pool, 251 teeth were selected for the micro-CT group, which underwent scanning to establish two anatomically paired groups (n=10) (De-Deus et al., 2020). This highlights the challenges, time consumption, and high costs associated with this method. Furthermore, it's important to recognize that certain tooth parameters, including donor age, ethnicity, and environmental factors, cannot be adequately standardized through these methods. These factors influence the mechanical properties of dentin (Hulsmann, 2022; Ivancik et al., 2014; Panfilov et al., 2016). Dentin, a hard tissue occupying the bulk of the human tooth, boasts a complex hierarchical structure. It
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 48 comprises around 45% mineral material, 33% organic material, and 22% water (Montoya et al., 2015; Panfilov et al., 2016). The microstructure of dentin is primarily defined by its tubules, which radiate outward from the pulp toward the dentin–enamel junction. Each tubule contains a lumen encased by peritubular dentin, comprising densely mineralized apatite crystals and a small portion of organic proteins. Intertubular dentin, situated between the tubules, is characterized by a matrix of collagen fibers fortified by apatite (Montoya et al., 2015; Ryou et al., 2015). Following the third decade of life, a shift occurs in the microstructure of dentin, marked by an increase in inorganic material content as the tubules gradually fill with it (Montoya et al., 2015; Montoya et al., 2016; Panfilov et al., 2016; Ryou et al., 2015). This leads to a reduction in tubule density and dentinal diameter. These changes result in alterations to its mechanical properties, including heightened elastic modulus and hardness, alongside diminished strength and fatigue crack resistance (Li et al., 2015; Montoya et al., 2015; Montoya et al., 2016; Pashley, 1985; Ryou et al., 2015). The aging process of dentin commences from the root dentin and progresses towards the coronal direction (Montoya et al., 2015; Yan et al., 2017). In older donors, the occlusion rate of dentinal tubules is highest at the root apex and closer to the pulp, while in younger donors, it is greater near the cementum (Yan et al., 2017). In this manner, the age of the donors exerts an influence on the properties of the dentin. In this way, the use of extracted teeth obtained from patients of unknown age may have the potential to significantly impact the results (Alak et al., 2023; Arola et al., 2017; De-Deus et al., 2023). Moreover, a study examining the microstructure and mechanical properties of dentin revealed disparities between donors from the United States of America and those from Colombia (Ivancik et al., 2014). Due to the aforementioned reasons, achieving complete standardization with current methods is nearly impossible. 3D-printed teeth, which emulate the characteristics of natural teeth, have the potential to address their constraints (Al-Sudani & Basudan, 2017; Dobros et al., 2022; Reymus et al., 2021; Reymus et al., 2020). Moreover, they offer a practical way for developing the skills in access opening, canal preparation, radiographic length control, and canal filling (Dobros et al., 2022; Reymus et al., 2019). Challenging to gather: There are no issues with collection, as the selection of various teeth is unrestricted and they are readily available in abundant quantities (Al-Sudani & Basudan, 2017; Dobros et al., 2022; Hulsmann, 2022; Kroger et al., 2017; Reymus et al., 2019). Furthermore, an online platform facilitating institutions to exchange their printable files would greatly benefit the community as a whole (Reymus et al., 2019). Ethical concerns: Only 3D printed teeth created from cone beam computer tomography (CBCT) or micro-CT scans of actual teeth should necessitate donor consent for their use (Dobros et al., 2022; Holden & Dracopoulos, 2017; Hulsmann, 2022); nevertheless, the quantity of natural teeth required would be minimal. Potential for cross-infection and storage concerns: they pose no risk of crossinfection, offer enhanced hygiene, and are easier to handle as they do not require storage
INTRODUCTION 49 in liquid, ensuring a secure training environment (Al-Sudani & Basudan, 2017; Kolling et al., 2021; Kroger et al., 2017). Standardization: they are realistic and standardized, ensuring consistent difficulty levels for every student. Consequently, fair scoring is guaranteed (Al-Sudani & Basudan, 2017; Bitter et al., 2016; Dobros et al., 2022; Fakhr & Nagy, 2023; Kroger et al., 2017; Pouhaer et al., 2022; Reymus et al., 2019), facilitated by the establishment and standardization of specific grading criteria (Gancedo-Caravia et al., 2020; Lugassy et al., 2021). This standardization enables students and instructors to concentrate on learning and teaching clinical procedures without being hindered by the morphological diversity of natural teeth (Decurcio et al., 2019). Furthermore, in ex vivo studies, this morphological standardization significantly enhances result credibility (De-Deus, 2012; De-Deus et al., 2020; Karatekin et al., 2019; Ordinola-Zapata et al., 2014; Xu et al., 2021; Zhu et al., 2024). 3D printed teeth offer additional advantages in pre-clinical courses by gradually introducing canal anatomy complexities (Al-Sudani & Basudan, 2017; Fakhr & Nagy, 2023; Ordinola-Zapata et al., 2014). Students have the opportunity to practice procedures repeatedly and compare various protocols, a benefit also applicable to ex vivo studies (Al- Sudani & Basudan, 2017; Fakhr & Nagy, 2023; Ordinola-Zapata et al., 2014; Yekta- Michael et al., 2021). It follows logically that techniques thoroughly covered in preclinical courses are executed more confidently and with less stress when students treat patients for the first time (Hanafi et al., 2020). In a study by Tchorz et al. (2015), the impact of students training with artificial teeth versus extracted human teeth on the quality of their initial root canal treatments performed on patients was compared. They found no discernible differences between the two groups (Tchorz et al., 2015), indicating that artificial teeth are indeed appropriate for endodontic training. Several studies highlight students' strong positive feedback regarding the utilization of 3D printed teeth for standardized endodontic training and as realistic simulations of clinical treatment (Kolling et al., 2021; Reymus et al., 2019; Reymus et al., 2021). Furthermore, instructors also value 3D printed teeth, likely due to their firsthand experience with the challenges faced during pre-clinical courses using natural teeth (Bitter et al., 2016; Gancedo-Caravia et al., 2020). Another application of 3D printed teeth is in addressing complex anatomical clinical cases. This enables clinicians to comprehend the root canal configuration and test specific clinical treatments before implementing them on a patient. By training with 3D printed models, clinicians can explore various approaches, enhancing their confidence levels for the actual treatment procedure (Byun et al., 2015; Liang et al., 2018; Tonini et al., 2021). 1.5.2 How 3D printed teeth are manufactured Additive manufacturing, commonly referred to as 3D printing, involves the fabrication of parts by merging materials based on 3D model data, typically through layerby-layer deposition (ISO/ASTM, 2021). This innovative technology utilizes 3D data, post-processing tools, and algorithms to manipulate and adjust multiple layers, resulting in the creation of a 3D model. Subsequently, a 3D printer employs a specific material to
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 50 produce the desired part (Liang et al., 2018; Shah & Chong, 2018; Xu et al., 2021) (Figure 1). Figure 1. 3D printing process (https://www.mdpi.com/about/openaccess) The initial phase of 3D printing teeth involves acquiring a digital model derived from computer tomography scan data, laser scan data, or created through computer-aided design (Shah & Chong, 2018; Walker & Humphries, 2019). The scan data undergo processing through 3D construction software to produce data in STL format (Cui et al., 2018; Xu et al., 2021). The STL format, which stands for Standard Tessellation Language or Standard Triangulation Language, represents virtual 3D surfaces using triangulation (tessellation). Each triangular face is defined by three corner points and the corresponding surface. Curved surfaces are approximated by polygons. Increasing the number of polygons, by reducing the size of the triangles, enhances the object's surface resolution. However, this also significantly increases the number of triangles in the file, leading to larger file sizes (Kessler et al., 2020; Paul & Anand, 2015). The precision of 3D printers is determined by two main factors: XY resolution, which relates to horizontal accuracy, and layer thickness, representing the Z-axis or vertical accuracy. Layer thickness generally dictates the surface quality, with thinner layers yielding smoother objects. However, thinner layers also result in longer printing times (Anderson et al., 2018; Kessler et al., 2020). In certain 3D printing methods, support material is utilized to fill areas beneath overhangs, within cavities, and holes, and the process of removing this support material varies depending on the technology employed (Kessler et al., 2020). Stereolithography (layer thickness 25–100 µm) The polymerization process involves a single ultraviolet laser and a vat containing liquid resin (Anderson et al., 2018; Kessler et al., 2020; Kim et al., 2016; Reymus et al., 2020; Walker & Humphries, 2019). A computer-controlled mirror directs the ultraviolet laser onto the resin surface, curing it layer by layer. Through sequential curing, the layers fuse together to form a solid mass, starting from the bottom of the object and progressing upwards; this method is known as the bottom-up approach (Anderson et al., 2018; Kessler et al., 2020; Kim et al., 2016). Alternatively, in the top-down approach, the platform is lowered vertically into the reservoir, and the resin layer is exposed to a laser scanning from the bottom of the reservoir (Kessler et al., 2020). Following printing, the model is removed and undergoes additional post-curing in a ultraviolet cabinet to reduce residual resin content (Kessler et al., 2020; Kim et al., 2016). The resulting model material is robust, slightly brittle, and
INTRODUCTION 51 relatively lightweight (Kim et al., 2016). Support material is necessary for this process (Kessler et al., 2020). Digital Light Processing (layer thickness 25–100 µm) The polymerization occurs through a light source emitted from a traditional Digital Light Processing projector, with the liquid resin contained within a vat (Kessler et al., 2020; Kim et al., 2016; Reymus et al., 2020). The projector illuminates the resin with a 2D image, building the object layer by layer as the platform undergoes manipulation (Anderson et al., 2018). This process resembles Stereolithography, albeit without a moving beam (Shah & Chong, 2018). Support material is necessary for this process (Kessler et al., 2020). Fused Deposition Modelling, with layer thickness options of 178 or 254 µm, involves depositing layers of molten material from a filamentous nozzle which then solidify within 0.1s. Typically, Fused Deposition Modelling is characterized by lower accuracy (Anderson et al., 2018; Kessler et al., 2020; Kim et al., 2016; Lee et al., 2015; Walker & Humphries, 2019), and may require additional support material (Kessler et al., 2020). ColorJet printing technology (with a layer thickness of 50–100 µm) operates by selectively dispersing a binding agent onto layers of powder, which are then fused together (Anderson et al., 2018; Kessler et al., 2020; Kim et al., 2016; Walker & Humphries, 2019). Nevertheless, its accuracy, surface finish, and strength are generally poor (Shah & Chong, 2018). Unlike other methods, support material is unnecessary because the surrounding powder provides support for unconnected parts. During the finishing process, a cyanoacrylate-based material is infused into the prototype to reinforce its structure and reduce porosity (Kessler et al., 2020; Kim et al., 2016). Selective Laser Sintering printers (with a layer thickness of 30–100 µm) and Selective Laser Melting printers (with a layer thickness of 20–100 µm) employ a computer-guided laser and a roller mechanism to distribute layers of powdered material onto the preceding layer. Subsequently, each new layer undergoes sintering (Selective Laser Sintering) or melting (Selective Laser Melting) (Anderson et al., 2018; Kessler et al., 2020; Kim et al., 2016; Walker & Humphries, 2019), allowing for the printing of thermoplastic polymer, metal, ceramic, or glass (Kessler et al., 2020; Shah & Chong, 2018). These printers operate without the need for support material (Kessler et al., 2020). PolyJet™ and MultiJet printing technology, with layer thickness capabilities of up to 16 µm, employs photosensitive resin to achieve exceptional precision in product detailing. This method transcends limitations imposed by geometric shapes and is particularly adept at simulating root canal anatomy. However, its limitations include the device's high cost and the instability of resin-based materials over time, which is a common issue with all resin-based technologies (Rouze l'Alzit et al., 2022). Conceptually comparable to the 2D printing process of an inkjet printer, it offers remarkable accuracy (Kessler et al., 2020; Kim et al., 2016; Kolling et al., 2021; Kroger et al., 2017; Liang et al., 2018; Walker & Humphries, 2019). This technology enables the printing of two distinct materials within a single print job: a model material and a supporting material (Kessler et al., 2020; Kim et al., 2016; Kroger et al., 2017; Lee et al., 2015; Shah & Chong, 2018). The process involves the printer nozzles moving along the XY plane, dispensing liquid photosensitive resin onto the printer bed, followed by curing the resin with a ultraviolet lamp. Once the initial layer is complete, the printer bed lowers by the specified layer thickness in the Z plane, and the deposition of subsequent layers repeats. This
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 52 method holds promise as an appealing choice for low-volume manufacturing within research environments. In areas where hollow parts or overhangs are present, the nozzles apply a layer of removable support material (Anderson et al., 2018; Fahad et al., 2013; Herpel et al., 2021; Kent et al., 2017; Kim et al., 2016; Kroger et al., 2017; Lee et al., 2015; Macdonald et al., 2017; Quan et al., 2020; Walker & Humphries, 2019). Methods for removing support material include manual breaking, dissolution under water pressure or with sodium hydroxide, or melting (Fahad et al., 2013; Kent et al., 2017; Kessler et al., 2020; Kroger et al., 2017; Stratasys, 2019). The distinction between these two printing technologies lies solely in their support materials and post-processing demands (Anderson et al., 2018; Kessler et al., 2020; Kim et al., 2016). 1.5.3 Problems with 3D printed teeth 3D printed teeth are currently limited to studies focusing solely on root canal shape and are not suitable for assessing root canal cleanliness or dentin alterations (Hulsmann, 2022). Nevertheless, recent investigations by Choi et al. (2021) and Teves Cordova et al. (2024) have proposed enhancements to a formulated 3D printed tooth by integrating a slot for inserting a dentin segment. This adaptation allowed the evaluation of different irrigation protocols for both bacterial contamination of the dentin and smear layer removal, respectively. However, additional research utilizing this prototype is necessary (Choi et al., 2021; Teves Cordova et al., 2024). However, they hold potential for use in studies concerning obturation. Karatekin et al. (2019) and Gok et al. (2017) assessed various obturation techniques in 3D printed teeth featuring C-shaped canals, employing cross-sectional analysis at different levels, and examining images under magnification (Gok et al., 2017; Karatekin et al., 2019). In Karatekin et al.'s study, 3D printed teeth were prepared post-printing, which the authors acknowledged as a potential limitation since one major advantage of 3D printed teeth is standardization, and the bias introduced by preparation was not considered. In contrast, Gok et al. prepared the natural tooth prior to micro-CT scanning, a method more suitable for obturation studies. Additionally, Peters et al. (2021) utilized 3D printed teeth derived from a previously prepared tooth to evaluate the quality of obturation among students (Peters et al., 2021). Furthermore, it has been noted that removing support material from parts containing intricate features can be challenging (Fahad et al., 2013; Hulsmann, 2022; Orel et al., 2021; Reymus et al., 2019). No study has demonstrated the complete absence of support material within the internal root canal anatomy, with the majority failing to elucidate the protocol employed for its removal from inside the root canals, or whether such removal was undertaken at all (Cui et al., 2018; Gok et al., 2017; Karatekin et al., 2019; Kolling et al., 2021; Liang et al., 2018; Xu et al., 2021). This could result in partial or complete filling of the canals with support material, potentially impacting the variables of interest. Reymus et al. (2019) conducted a retrograde preparation on the apical 5 mm of the natural tooth using hand files up to an ISO file 10 to ensure patency before a CBCT scan. Subsequently, all canals were prepared up to an ISO file 20. Following this, the access cavity was sealed with a cotton pellet and a radiopaque filling. Following printing with the Stereolithography technique, the 3D printed teeth underwent a 2-minute alcohol cleaning in an ultrasonic bath. Subsequently, they were centrifuged for 10 minutes at 3500 revolutions per minute to remove the uncured resin from the canals. The authors
INTRODUCTION 53 emphasized the necessity of canal patency for effective uncured resin removal, hence the execution of retrograde preparation. However, the authors did not assess whether the canals were free of uncured resin following their protocol (Reymus et al., 2019). In a study by Orel et al. (2021) comparing various preparation systems, it was noted that the apical 3 mm of the canals of 3D printed teeth, created using the Stereolithography technique, were obstructed by support material. Consequently, they fabricated another 3D printed tooth separated along the long axis of the tooth into two pieces, which were then secured together with a clamp (Orel et al., 2021). Given that the study aimed to assess the effects of different preparation systems on canal walls, the separation of teeth and their reliance on a clamp during the process may have introduced potential effects on the variables of interest that were not addressed by the authors. Several studies examined the precision of 3D printed teeth by evaluating the external surface (Kulczyk et al., 2019; Liang et al., 2018; Reymus et al., 2019), while others focused on the internal root anatomy (Cui et al., 2018; Liang et al., 2018; Xu et al., 2021). Reymus et al. (2019) solely examined the external surface of the 3D printed teeth. They compared the STL file of the natural tooth with STL files of the 3D printed teeth acquired through dental scanning. Although they suggested that the results might be comparable for the internal root anatomy, they did not conduct any assessment of this parameter(Reymus et al., 2019). Liang et al. (2018) conducted a comparative study using CBCT to evaluate the precision of the external surface and internal root anatomy at 3, 6, and 9 mm from the apex in twenty natural premolars and their corresponding 3D printed teeth. The findings indicated no significant differences between the 3D printed teeth and the natural teeth (Liang et al., 2018). However, it's crucial to note that the natural teeth were categorized into four groups and prepared to different file sizes (25#06, 30#09, 35#04, and 40#40, respectively). Additionally, only three levels of the root canal were assessed. Therefore, these findings may not be extrapolated to teeth intended for studies or educational purposes involving intricate canal anatomy. Cui et al. (2018) conducted a study in which they scanned six premolar teeth (three maxillary and three mandibular) and utilized these scans to create 3D printed teeth using the PolyJet technique. The support material was removed through melting, although the specific protocol was not detailed, and it was not specified whether the 3D printed teeth underwent access cavity preparation. The study concluded that the area and volume of the natural canals were not significantly different from those of the printed canals (Cui et al., 2018). However, for model validation, only one 3D printed tooth was compared with its respective natural tooth, resulting in six experimental pairs. Consequently, due to this methodology and the limited number of 3D printed teeth, it cannot be definitively concluded that the consistency of 3D printing internal root anatomy is maintained on a larger scale. Xu et al. (2021) assessed the shaping ability of four single-file systems on 3D printed teeth created via the PolyJet technique. Micro-CT scans were conducted before and after preparation for each specimen (Xu et al., 2021). However, the authors failed to provide any details regarding the support material used. Another limitation is that, as the 3D
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 54 printed teeth were not compared with natural teeth, the reliability and consistency of the printing technique cannot be assured. A primary concern highlighted in numerous studies is the discrepancy in radiopacity and hardness between the resin and dentin (Hulsmann, 2022; Karatekin et al., 2019; Kolling et al., 2021; Ordinola-Zapata et al., 2014; Reymus et al., 2019). In the study by Reymus et al. (2019), students perceived the preparation of 3D printed teeth to be easier than that of natural teeth, attributed to this hardness difference (Reymus et al., 2019). However, it's worth noting that the natural tooth underwent preparation up to an ISO file 20 before scanning to obtain the STL file, which could have also influenced the ease of preparation by the students. In a study conducted by Cresswell-Boyes et al. (2022), their findings suggest that 3D printed typodont teeth, designed to mimic the mechanical properties of enamel and dentin, can exhibit mechanical comparability to extracted human teeth, despite variations in material compositions (Cresswell-Boyes et al., 2022). However, it's worth noting that they utilized a 50 µm layer printer and solely printed a typodont tooth without internal anatomy. While these results are promising, further research is warranted to explore the potential application of these materials in future endodontic studies involving 3D printed teeth. Another consideration arises from the fact that the minimum layer thickness of 3D printers is 16 µm. However, it's worth pointing out that most apical foramen diameters typically fall within the range of 0.18 to 0.29 mm (Marroquin et al., 2004; Orel et al., 2021), suggesting that this limitation may not be significant. Nonetheless, reproducing smaller structures such as lateral canals and narrow isthmuses may pose challenges (Pouhaer et al., 2022; Reymus et al., 2019). The process of producing 3D printed teeth comprises several steps, each of which presents potential sources of error (Kulczyk et al., 2019). A range of robust freeware and open-source software solutions exist for creating 3D printed teeth (Cui et al., 2018; Kulczyk et al., 2019; Reymus et al., 2020). However, the lack of standardization and established protocols fosters divergent measurement methods and study accuracies, thereby hindering the comparison of results across different studies (Cui et al., 2018). Another consideration pertains to the resolution of scans required to achieve highquality 3D printed teeth. Kulczyk et al. (2019) conducted a comparative analysis of the external surface of 3D printed teeth obtained through various 3D data acquisition methods, including CBCT, optical 3D scanning, and micro-CT. They concluded that while CBCT can provide sufficient data for 3D printed teeth, it does not match the precision of micro-CT. For instance, in their study, CBCT scans of a canine and a molar produced data with 65,340 and 98,624 triangles, respectively, at high resolution, whereas micro-CT scans yielded significantly higher numbers: 11,510,788 and 24,974,112 triangles for each tooth, respectively. As previously noted, higher resolution in the original data leads to better quality 3D models and subsequently, better quality 3D printed objects. However, 3D models created based on micro-CT data offer greater accuracy than current 3D printers can achieve.(Kulczyk et al., 2019). Additionally, very high-resolution STL files result in excessively large files that can pose challenges for 3D printing software to process.
INTRODUCTION 55 Therefore, in order to attain the required level of standardization and the development of protocols, addressing the issues surrounding 3D printed teeth as presented here should be prioritized.
2. JUSTIFICATION AND AIMS
MATERIALS AND METHODS 63 4.1.2 Artificial specimen selection In the artificial teeth group, fourteen TrueTooth® (DELabs) replicas (#15-001) were used. TrueTooth® replica #15-001 is a maxillary molar with a distobuccal canal with a severe curvature and a large mesiobuccal canal, ribbon-shaped, with a moderate curvature (DELabs); these features are adequate for the purposes of the present study. The 14 mesiobuccal canals were utilized to assess the effect of the support material, while the distobuccal canals served for comparison with the 14 natural buccal canals. The preparation of artificial teeth was equal to natural teeth. 4.1.3 Initial micro-CT scanning The specimens underwent scanning with a micro-CT device (Skyscan 1174; Bruker) using 50 KV and 800 mA energy. A 0.25 mm thick aluminum filter was employed, with rotational steps of 1.0 increments covering a total rotation of 180º. Image pixel size was 16.65 μm, and the exposure time was set at 12000 ms. The images were reconstructed utilizing NRecon v 1.7.46 software (Bruker micro-CT), introducing the algorithms designed for correcting of ring artifacts (5), smoothing (3), and beam hardening (20%). The CTAnv v 1.20.3.0 software (Bruker micro-CT) was employed to calculate the initial volume. The region of interest was defined from the furcation region to the root apex. The degree of homogeneity among the groups concerning the initial volume, working length, and degree of curvature was statistically evaluated and confirmed (p > 0.05), signifying adequate paring between natural teeth buccal canals and artificial teeth distobuccal canals. 4.1.4 Root Canal Preparation An electric motor X-Smart® Plus (Dentsply Sirona) was used to operate the files with in-and-out pecking motion with an amplitude of 2–3 mm. A continuous clockwise rotation motion was used, according to the manufacturer’s recommendations. The number of pecking movements required for each file to reach the working length and the duration of file rotation within the canal until reaching the working length were recorded, using a start-stopwatch. If the working length wasn’t reached within 3 pecking movements, the file was withdrawn from the canal to clean debris from the flutes. During this period, the start-stopwatch was paused. A glyde path was established using a ProGlyder® file (Dentsply Sirona) until reaching the working length. Subsequently, all files from the ProTaper Gold® (Dentsply Sirona) system were employed up to the working length, following the sequence SX, S1, S2, F1, and F2. Patency was confirmed after each file’s use with a K-file #10 (Dentsply Sirona). In all groups, the files were used to prepare only two canals before being replaced. Between each file, root canal irrigation was carried out using 5.25% sodium hypochlorite (Cerkamed), as indicated by the TrueTooth® (DELabs) replicas developer (Buchanan, 2014), and an IrriFlex® 30G needle (Produits dentaires SA), inserted as apically as feasible. Each canal was irrigated with a total of 25 Ml. Subsequently, the canals were dried with absorbent paper points (Dentsply Sirona), followed by a new
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 64 micro-CT scan conducted under the same scanning and reconstruction parameters as initially established. 4.1.5 Micro-CT analysis Images were reconstructed using the Nrecon v 1.7.46 software (Bruker micro-CT) and superimposed with geometric alignment using the DataViewer v 1.5.6.2 software (Bruker micro-CT). The CTAnv v 1.20.3.0 software (Bruker micro-CT) was employed to calculate the quantitative parameters. The region of interest was defined from the furcation region to the root apex. The initial volume and final volume were acquired, with initial volume representing the preoperative volume of the root canals and the final volume representing the volume of the root canals after the preparation. Using these values, the root canal volume increase was calculated using the formula: final volume minus initial volume. 4.1.6 Total preparation time The individual time required for each file to reach the working length were recorded and summed to determine the total preparation time needed for each canal. 4.1.7 Total number of pecking movements The total number of pecking movements required for the preparation of each canal was calculated by summing the number of pecking movements needed for each file to reach the working length. 4.2 MATERIAL AND METHODS FOR SECOND PRIMARY AIM The study protocol was approved by the ethics committee of Fernando Pessoa University (FCS/PI 429/23). (Appendix 2) Based on data from a previous study (Gagliardi et al., 2015) in which shaping ability was assessed a sample size calculation was performed using G*Power 3.1.9.7 software for windows (Heinrich Heine, Universität Düsseldorf, Germany) with an α type error of 0.05 and a β power of 0.95 and for an effect size of of 1.6 (volume increase) and of 1.79 (percentage of unprepared area) input into the t test family. This calculation yielded a necessary sample size of 20 samples (10 per group) and 16 samples (8 per group) to detect significant differences between groups, respectively. Given that the maximum value obtained was ten samples per group, this number was utilized. 4.2.1 Natural tooth selection Out of an initial pool of 45 maxillary permanent molars, which were extracted for reasons unrelated to this study, specimens were collected and preserved in distilled water until required. Radiographs were captured from both mesiodistal and buccolingual directions to ensure that the inclusion criteria were met. The inclusion criteria were teeth with fully formed apices, absence of root fractures, no signs of external and internal resorption or decayed tissue in the region of interest, absence of previous endodontic treatment, absence of calcifications, presence of separated canals and apical foramens,
MATERIALS AND METHODS 65 and a curvature degree ranging between 20° and 40°. The curvature degree was assessed using Schneider’s method (Schneider, 1971), involving the drawing of two lines: one parallel to the canal’s long axis, and the other from the apical foramen to intersect with the first line at the point where the canal deviated from the tooth’s long axis. Out of the initial sample, 14 teeth were selected. The endodontic cavities were prepared using a round diamond bur #4 and an Endo-Z™ bur (Dentsply Sirona) driven by a high-speed handpiece under water cooling. Exploration of the canals was conducted using a K-file #10 (Dentsply Sirona) until the file’s tip was just visible through the apical foramen, ensuring canal patency. The teeth crowns were then sectioned 4mm from the cementoenamel junction to establish a platform for facilitating future references. The specimens underwent scanning with a micro-CT device (Skyscan 1174; Bruker) using 50 KV and 800 mA energy. A 0.25 mm thick aluminum filter was employed, with rotational steps of 1.0 increments covering a total rotation of 180º. Image pixel size was 16.65 μm, and the exposure time was set at 12000 ms. The images were reconstructed utilizing NRecon v 1.7.46 software (Bruker micro-CT), introducing the algorithms designed for correcting of ring artifacts (3), smoothing (3), and beam hardening (40%). CTAn v 1.20.3.0 software (Bruker micro-CT) was utilized to generate one STL file of each tooth and another for the respective canal anatomy. These STL files were then exported to a free software platform (MeshLab v. 2021.10) for qualitative evaluation of canal configuration and selection of the natural tooth to replicate. The selected tooth was a second left maxillary molar featuring three fully separated roots, each presenting a single independent canal without any lateral canals. The mesiobuccal root exhibited an oval canal, while distobuccal root presented a small diameter round canal and palatal root presented a large diameter round canal (Figure 2). Figure 2. Cross-sectional views of micro-CT scan of the natural tooth (https://www.mdpi.com/about/openaccess)
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 66 4.2.2 3D printing process and support material removal protocol The STL file of the tooth were simplified and prepared for 3D printing using the “Simplification: Quadric Edge Collapse Decimation” filter (Moraes et al., 2019). This step was necessary as high-resolution STL files tend to be excessively large, posing challenges for 3D printing software to process (Reis et al., 2022). Original STL file presented 3 298 498 vertices and 6 598 466 faces with a file size of 314 Mbytes. After simplification, the STL file presented 798 881 vertices and 1 599 232 faces with a file size of 76.2 Mbytes. The STL file was printed using PolyJet™ technology with a Stratasys Object30 Prime™ printer (Stratasys Ltd), in High-Quality mode featuring a layer thickness of 16 µm. High Temperature RGD525™ (Stratasys Ltd) was the printing material chosen, along with SUP706B™ (Stratasys Ltd) as the support material. For printing, the tooth was displayed horizontally with its mesial surface in contact with the printer bed, and its long axis aligned parallel to the X axis of printer head and bed (Figure 3). Figure 3. Teeth orientation on the printer bed (https://www.mdpi.com/about/openaccess) Following printing, the support material surrounding the teeth and inside the access cavity was manually removed. The support material removal protocol, involved the use of a K-file #15 (Dentsply Sirona), a 30G polypropylene body needle Irriflex® (Produits dentaires SA), an Endoactivator® (Dentsply Sirona) with a small Endoactivator® Tip (15/.02) (Dentsply Sirona). Irrigants used in the process included a 5% solution of sodium hydroxide, 5 % Derquim® LM 01 alkalin detergent (ITW Reagents, S.R.L.), distilled water and 70% alcohol. The support material removal protocol, summarized in a flowchart (Figure 4), consisted on the following steps: (1) cleaning the access cavity with 5 ml of 5% sodium hydroxide, and for each canal, (2) advancing passively into the canal the K-file #15 until the tip of the file was just visible through the apical foramen to ensure canal patency, followed by irrigation with 5 ml of 5% sodium hydroxide with high pressure. This step was repeated 5 times to achieve irrigant extrusion by the end of this step. This was
MATERIALS AND METHODS 67 followed by (3) irrigation with 35 ml of 5% sodium hydroxide. During this step, if there was loss of irrigant extrusion, indicating a loss of patency, a K-file #15 was used as previously mentioned, (4) the irrigant was subjected to sonic activation with Endoactivator® (Dentsply Sirona) at high frequency for 30 seconds with up-and-down movements, with an amplitude of 4 mm. Following this, (5) the canal was irrigated with 5 ml of 5% sodium hydroxide, (6) followed by another round of irrigant sonic activation as previously described. This process continued with (7) irrigation using 5 ml of 5 % Derquim® LM 01 alkalin detergent (ITW Reagents, S.R.L.), (8) subsequent irrigant sonic activation as described before, (9) irrigation with 5 ml of distilled water, (10) additional irrigant sonic activation as described before, (11) irrigation with 5 ml of distilled water, and finally (12) irrigation with 2 ml of 70% alcohol. Figure 4. Flowchart of support material removal protocol (https://www.mdpi.com/about/openaccess)
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 68 Thus, a total of 20 3D printed teeth sample (n=20) were obtained and randomly assigned (www.random.org) to each of the two experimental groups (n=10), ProTaper Gold® (Dentsply Sirona) and Endogal® (Endogal, Galician Endodontics Company) (Figure 5). Figure 5. Natural tooth (A) and 3D printed teeth (B and C) from different views (https://www.mdpi.com/about/openaccess) 4.2.3 3D printed teeth initial micro-CT scanning The specimens underwent scanning with a micro-CT device (Skyscan 1174; Bruker) using 50 KV and 800 Ma energy, with rotational steps of 1.0 increments covering a total rotation of 180º. Image pixel size was 16.65 μm, and the exposure time was set at 12000 ms. The images were reconstructed utilizing NRecon v 1.7.46 software (Bruker micro- CT), introducing the algorithms designed for correcting of ring artifacts (5), smoothing (3), and beam hardening (50%). 4.2.4 Root canal preparation All the preparations were performed by a single operator, the doctoral student, with 22 years of clinical experience in the field of endodontics and with previously clinically experienced in ProTaper Gold® (Dentsply Sirona) and Endogal® (Endogal, Galician Endodontics Company) systems. The teeth were secured in position using the ProTrain system® (Simit Dental Srl). The working length was determined by subtracting 1 mm from the value obtained during the support material removal protocol.
MATERIALS AND METHODS 69 An X-Smart® Plus electric motor ( Dentsply Sirona) was used to operate the files employing in-and-out pecking motion with an amplitude of 2-3 mm, in a continuous clockwise rotation according to the manufacturer’s recommendations. The number of pecking movements required for each file to reach the working length and the duration of file rotation within the canal until reaching the working length were recorded, using a start-stopwatch. If the working length wasn’t reached within 3 pecking movements, the file was withdrawn from the canal to clean debris from the flutes. During this period, the start-stopwatch was paused. 4.2.4.1 Preparation of natural tooth and group I with ProTaper Gold® A glyde path was established using a ProGlyder® File (Dentsply Sirona) until reaching the working length. Subsequently, all files from the ProTaper Gold® (Dentsply Sirona) system were employed up to the working length except the SX file that was used only for coronal interferences removal, following the sequence SX, S1, S2, F1, and F2. Patency was confirmed after each file’s use with a K-file #10 (Dentsply Sirona). The files were used to prepare only one tooth before being replaced. Root canal irrigation was conducted between each file, using 5ml 5,25% NaOCl (Cerkamed) for NT and 5 ml distilled water for 3DPT, with an IrriFlex® 30G needle (Produits dentaires SA), inserted as apically as feasible, activated with Endoactivator® at high frequency with the small tip for 30 seconds. After preparation the canals were irrigated twice with 5 ml of irrigant and activated with Endoactivator® (Dentsply Sirona). Consequently, the total volume of irrigation for each canal was 40 ml. Finally the canals were dried with paper points (Dentsply Sirona). 4.2.4.2 Preparation of group II with Endogal® A glyde path was established by using the A File (Endogal, Galician Endodontics Company) until working length was reached. All files from the Endogal® (Endogal, Galician Endodontics Company) system, were employed up to the WL except the X file that was used only for coronal interferences removal, following the sequence X , B, C and D. Patency was confirmed after each file’s use with a K-file #10 (Dentsply Sirona). The files were used to prepare one tooth before being replaced. Root canal irrigation was conducted between each file with 5ml distilled water using a Irriflex® 30G needle (Produits dentaires SA), inserted as apically as feasible, and activated with Endoactivator® at high frequency with the small tip for 30 seconds. After preparation the canals were irrigated three times with 5 ml of irrigant and activated with Endoactivator® (Dentsply Sirona).. Consequently, the total volume of irrigation for each canal was 40 ml. Finally the end the canals were dried with paper points (Dentsply Sirona).
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 70 4.2.5 Micro-CT analysis A new micro-CT was performed on natural tooth and both 3D printed teeth groups according to the same scanning and reconstruction parameters as those established initially respectively. Images before and after preparation were superimposed with the 3D registration application of the DataViewer v 1.5.6.2 software (Bruker micro-CT). Subsequently, the data obtained were processed using CTAnv v 1.20.3.0 software (Bruker micro-CT). The region of interest was set from the furcation region to root apex. The volume of dentine removed, and centroids were quantified by subtracting the values before preparation to the values after preparation (Hulsmann, 2022). Regarding the sample orientation during evaluation, a positive value for alteration of centroid X indicated a shift in buccal direction, centroid Y in mesial direction and centroid Z in apical direction (Perez Morales et al., 2021). Transportation was examined by calculating the vectorial translocation of all sections X, Y and Z coordinate values using the following formula, where “a” represents after and “b” before preparation: (Xa-Xb)2+(Ya-Yb)2+(Za-Zb)2 (Serefoglu & Piskin, 2017; Ventura et al., 2024). The percentage of unprepared area was determined by comparing the number of static voxels with the total number of voxels present on root canal surface (Perez Morales et al., 2021). Tooth volume expansion evaluated for the 3D printed teeth, was expressed as the ratio of 3D printed teeth volume to the natural tooth volume (Lee et al., 2015). 4.2.6 Total preparation time The individual time required for each file to reach the working length were recorded and summed to determine the total preparation time needed for each canal. 4.2.7 Total number of pecking movements The total number of pecking movements required for the preparation of each canal was calculated by summing the number of pecking movements needed for each file to reach the working length. 4.3 STATISTICAL ANALYSIS The data collected were processed using the IBM SPSS Statistics vs. 26.0 software. The Shapiro-Wilk test was applied to verify data normality. Accordingly, to normal and nonnormal distribution, one-sample t-test or one-sample Wilcoxon signed rank test and Independent-Sample t-test or Mann-Whitney U test were applied. The significance level was 5% for all statistical tests (p < 0.05).
5. RESULTS Sections of this chapter has already been published as: Reis, T., et al., Root Canal Preparation of a Commercial Artificial Tooth versus Natural Tooth - A MicroCT Study. Applied Sciences, 2023. 13(16): p. 9400. https://doi.org/10.3390/app13169400 Reis, T., et al., Three-Dimensional Printed Teeth in Endodontics: A New Protocol for Microcomputed Tomography Studies. Materials. 2024; 17(8):1899. https://doi.org/10.3390/ma17081899
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 72 5. RESULTS 5.1 RESULTS OF FIRST PRIMARY AIM Table 1 presents the results associated to the first primary aim, displaying the mean, standard deviation, median, minimum, and maximum values of the initial root volume, final root volume, and root canal volume increase, assessed by Micro-Ct scans, of the artificial teeth mesiobuccal canals, aiming to access the effect of the support material. It should be noted that the mean values for volume increase are negative, respectively -1.32 mm3 and -17.66%. Figure 6 illustrates the 3D analysis of the mesiobuccal root canal before preparation of an artificial tooth, while Figure 7 displays the same root after preparation. For comparative purposes, Figures 8 and 9 displays a mesiobuccal root canal of a natural tooth before and after preparation, respectively. Table 1. Micro-CT analysis before and after preparation with ProTaper Gold® (Dentsply-Sirona) of artificial teeth Mesiobuccal Canal (https://www.mdpi.com/about/openaccess) Artificial Teeth Mesiobuccal Canal Initial canal volume (mm3) Mean ± SD 7.45 ± 0.42 Median 7.45 Min – Max 7.00 – 8.05 Final canal volume (mm3) Mean ± SD 6.14 ± 0.6 Median 5.93 Min – Max 5.30 – 7.86 Canal volume increase (mm3) Mean ± SD - 1.32 ± 0.82 Median - 1.58 Min – Max - 2.14 – 0.86 Canal volume increase (%) Mean ± SD - 17.66 ± 8.72 Median - 20.48 Min – Max - 28.89 – 5.41
RESULTS 79 Table 7. Time of preparation in seconds and number of pecking movements for natural tooth and 3D printed teeth with ProTaper Gold® (Dentsply-Sirona) Figure 12. Representative 3D reconstruction of micro-CT scans before (green) and after (red) preparation from different views. (A) natural tooth, (B) 3D printed teeth of ProTaper Gold® (Dentsply-Sirona) group and (C) 3D printed teeth of Endogal® (Endogal, Galician Endodontics Company) group (https://www.mdpi.com/about/openaccess) Natural Tooth 3D Printed Teeth Time of Preparation Number of pecking movements Time of Preparation Number of pecking movements ProGlyder® 27 17 Mean ± SD 27.30 ± 3.86 14.70 ± 6.24 Median 27.00 18.00 Min – Max 21 – 33 6 – 21 ProTaper Gold® Sx 27 18 Mean ± SD 25.80 ± 3.80 15.00 ± 7.07 Median 25.50 16.50 Min – Max 21 – 33 6 – 27 ProTaper Gold® S1 33 17 Mean ± SD 32.70 ± 4.35 15.30 ± 4.35 Median 33.00 18.00 Min – Max 27 – 39 9 – 18 ProTaper Gold® S2 31 19 Mean ± SD 32.10 ± 2.47 17.10 ± 3.76 Median 31.50 18.00 Min – Max 30 – 36 12 – 21 ProTaper Gold® F1 27 13 Mean ± SD 27.90 ± 4.25 13.20 ± 5.69 Median 27.00 13.50 Min – Max 24 – 36 6 – 21 ProTaper Gold® F2 34 18 Mean ± SD 31.20 ± 5.14 17.70 ± 8.30 Median 30.00 22.50 Min – Max 21 – 39 6 – 24 Total 179 102 Mean ± SD 177.00 ± 8.72 93.00 ± 34.41 Median 175.50 103.50 Min – Max 165 – 195 45 – 132
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 80 Table 8, Table 9, and Table 10 presents the results, displaying the mean, standard deviation, median, minimum, and maximum values, respectively, of the volume increase, volume of dentin removed, centroids, transportation, unprepared areas assessed by micro- CT scans, and the time of preparation and number of pecking movements required for root canal preparation, for both ProTaper Gold® (Dentsply Sirona) and Endogal® (Endogal, Galician Endodontics Company) systems, along with the time and number of pecking movements required for each file of each system. There were no statistically significant differences observed for all variables before preparation (p > 0.05). Both systems exhibited similar behavior, as indicated by the absence of statistically significant differences (p > 0.05) in measurements of canal volume, centroid X, Y, Z after preparation, volume of dentin removed, percentage of volume increase, centroid X, Y, Z alteration, transportation, and percentage of unprepared areas (Figure 11 and 12). However, the ProTaper Gold® (Dentsply Sirona) system demonstrated a higher percentage of volume increase and a lower percentage of untouched areas, at 47.68% and 54.97%, respectively, compared to the Endogal® (Endogal, Galician Endodontics Company) system, which showed percentages of 45.02% and 56.41%, respectively. The time required for preparation with ProTaper Gold® (Dentsply Sirona) system was higher compared to Endogal® (Endogal, Galician Endodontics Company) system with 177 seconds versus 111.6 seconds. Statistically significant differences were observed between the two systems regarding the total time of preparation (p < 0.05). Additionally, statistically significant differences were observed between the ProGlyder® (Dentsply Sirona) and A file (Endogal, Galician Endodontics Company) (p < 0.05). The number of pecking movements required for preparation with ProTaper Gold® (Dentsply Sirona) system was higher compared to Endogal® (Endogal, Galician Endodontics Company) system with 93 movements versus 47.40 movements. Statistically significant differences were observed between the two systems regarding the number of pecking movements (p < 0.05). Additionally, statistically significant differences were observed between the ProGlyder® (Dentsply Sirona) and A file (Endogal, Galician Endodontics Company) (p < 0.05).
RESULTS 81 Table 8. Micro-CT analysis before and after preparation with ProTaper Gold® (Dentsply-Sirona) and Endogal® (Endogal, Galician Endodontics Company) of 3D printed teeth (https://www.mdpi.com/about/openaccess) ProTaper Gold® Endogal ® Canal Volume (mm3) Initial Mean ± SD 12.12 ± 0.42 11.86 ± 0.66 Median 12.12 11.82 Min – Max 11.24 – 12.90 11.03 – 13.13 After Mean ± SD 17.89 ± 0.69 17.02 ± 0.61 Median 17.66 17.06 Min – Max 17.16 – 18.94 15.68 – 17.93 Volume of dentin removed Mean ± SD 5.77 ± 0.66 5.24 ± 1.02 Median 5.67 5.49 Min – Max 4.92 – 7.11 3.46 – 6.48 % Volume Increase Mean ± SD 47.68 ± 6.09 45.02 ± 10.89 Median 45.50 47.25 Min – Max 40.1 – 60.1 28.29 – 58.77 Centroid X (mm) Initial Mean ± SD 10.92 ± 0.07 10.92 ± 0.11 Median 10.87 10.96 Min – Max 10.85 – 11.04 10.70 – 11.02 After Mean ± SD 11.33 ± 0.13 11.37 ± 0.06 Median 11.32 11.35 Min – Max 11.12 – 11.54 11.30 – 11.47 Alteration Mean ± SD 0.41 ± 0.17 0.45 ± 0.09 Median 0.41 0.43 Min – Max 0.20 – 0.69 0.34 – 0.63 Centroid Y (mm) Initial Mean ± SD 10.37 ± 0.07 10.33 ± 0.06 Median 10.40 10.32 Min – Max 10.27 – 10.44 10.24 – 10.46 After Mean ± SD 10.53 ± 0.04 10.44 ± 0.05 Median 10.53 10.45 Min – Max 10.47 – 10.60 10.33 – 10.50 Alteration Mean ± SD 0.16 ± 0.07 0.11 ± 0.05 Median 0.15 0.13 Min – Max 0.05 – 0.27 0.02 – 0.16 Centroid Z (mm) Initial Mean ± SD 8.01 ± 0.11 8.03 ± 0.07 Median 8.04 8.01 Min – Max 7.70 – 8.09 7.94 – 8.13 After Mean ± SD 8.01 ± 0.10 8.07 ± 0.09 Median 8.02 8.11 Min – Max 7.84 – 8.20 7.89 – 8.14 Alteration Mean ± SD 0.01 ± .015 0.05 ± 0.09 Median 0.02 0.02 Min – Max - 0.25 – 0.27 - 0.09 – 0.19 Transportation (mm) Mean ± SD 0.48 ± 0.14 0.49 ± 0.11 Median 0.45 0.47 Min – Max 0.30 – 0.73 0.38 – 0.69 Unprepared area (%) Mean ± SD 54.97 ± 3.79 56.41 ± 5.11 Median 53.88 55.39 Min – Max 51.13 – 62.93 49.91 – 64.72
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 82 Table 9. Time of preparation in seconds and number of pecking movements with ProTaper Gold® (Dentsply-Sirona) of 3D printed teeth 3D Printed Teeth Time of Preparation Number of pecking movements ProGlyder® Mean ± SD 27.30 ± 3.86 14.70 ± 6.24 Median 27.00 18.00 Min – Max 21 – 33 6 – 21 ProTaper Gold® Sx Mean ± SD 25.80 ± 3.80 15.00 ± 7.07 Median 25.50 16.50 Min – Max 21 – 33 6 – 27 ProTaper Gold® S1 Mean ± SD 32.70 ± 4.35 15.30 ± 4.35 Median 33.00 18.00 Min – Max 27 – 39 9 – 18 ProTaper Gold® S2 Mean ± SD 32.10 ± 2.47 17.10 ± 3.76 Median 31.50 18.00 Min – Max 30 – 36 12 – 21 ProTaper Gold® F1 Mean ± SD 27.90 ± 4.25 13.20 ± 5.69 Median 27.00 13.50 Min – Max 24 – 36 6 – 21 ProTaper Gold® F2 Mean ± SD 31.20 ± 5.14 17.70 ± 8.30 Median 30.00 22.50 Min – Max 21 – 39 6 – 24 Total Mean ± SD 177.00 ± 8.72 93.00 ± 34.41 Median 175.50 103.50 Min – Max 165 – 195 45 – 132 Table 10. Time of preparation in seconds and number of pecking movements with Endogal® (Endogal, Galician Endodontics Company) of 3D printed teeth 3D Printed Teeth Time of Preparation Number of pecking movements Endogal® A Mean ± SD 6.90 ± 1.45 5.10 ± 1.45 Median 6.00 6.00 Min – Max 6 – 9 3 – 6 Endogal® X Mean ± SD 27.60 ± 3.69 9.30 ± 3.30 Median 27.00 9.00 Min – Max 24 – 33 6 – 15 Endogal® B Mean ± SD 18.00 ± 3.16 8.40 ± 1.90 Median 18.00 9.00 Min – Max 15 – 24 6 – 12 Endogal® C Mean ± SD 21.00 ± 4.00 10.50 ± 1.58 Median 21.00 10.50 Min – Max 15 – 27 9 – 12 Endogal®) D Mean ± SD 38.10 ± 6.17 14.10 ± 1.45 Median 39.00 15.00 Min – Max 27 – 48 12 – 15 Total Mean ± SD 111.60 ± 6.90 47.40 ± 3.10 Median 111.00 46.50 Min – Max 96 – 120 45 – 54
6. DISCUSSION Sections of this chapter has already been published as: Reis, T., et al., Root Canal Preparation of a Commercial Artificial Tooth versus Natural Tooth - A MicroCT Study. Applied Sciences, 2023. 13(16): p. 9400. https://doi.org/10.3390/app13169400 Reis, T., et al., Three-Dimensional Printed Teeth in Endodontics: A New Protocol for Microcomputed Tomography Studies. Materials. 2024; 17(8):1899. https://doi.org/10.3390/ma17081899
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 84 6. DISCUSSION 6.1 DISCUSSION OF FIRST PRIMARY AIM The first primary aim of this study was to assess how the support material of the TrueTooth® (DELabs) replica influences the preparation technique and its potential impact on volume changes evaluated through micro-CT scans. The findings revealed a negative mean value for root canal volume increase post-preparation in mesiobuccal canal, indicating a loss of volume after preparation, which appears absurd. It was also confirmed with the distobuccal canal that although it had a positive mean value, it still exhibited negative values in some samples for volume increase. Consequently, it is evident that the support material significantly affects the 3D analysis. Hence, the null hypothesis was rejected. As depicted in Figure 6 and Figure 7, the density of the support material post-preparation exceeded its pre-preparation density and approached that of the resin composing the root. Consequently, following canal preparation, the 3D analysis software no longer distinguishes these materials as separate entities, whereas such differentiation was feasible prior to preparation. To the best of the author’s knowledge, no prior studies have investigated this aspect using micro-CT, thus preventing direct comparison of our findings with existing literature. Our hypothesis suggests that density alterations might result from the heat generated by rotary files rubbing against the canal walls, causing the support material to compress against the areas untouched by the files. Such frictional heat phenomena have been documented and utilized in non-surgical endodontic retreatments (Betti & Bramante, 2001). The mesiobuccal canal is a large ribbon-shaped canal. Studies have indicated that oval and elongated oval root canals pose challenges during preparation. This difficulty arises from the tendency of files to stay centralized within the canal, creating a rounded preparation, leaving recesses untouched at the ends of the oval canal's largest diameter (Aazzouzi-Raiss et al., 2023; Arias & Peters, 2022; Lacerda et al., 2017; Paque et al., 2010; Wu et al., 2000). Canals with this morphology display a significant amount of unprepared areas, ranging from 10% to 82%, compared to small or round canals which exhibit between 10% to 50%, this could explain the difference of behaviour between artificial mesiobuccal and artificial distobuccal (Siqueira Junior et al., 2018). In this way, TrueTooth® (DELabs) cannot be used in preparation studies analysed by Micro-CT, due to incomplete removal of the support material by sodium hypochlorite as recommended by the developer (Buchanan, 2014). Future studies with different support material removal protocol are needed. However, the mean increase in root canal volume in the natural teeth group was 1.35 mm3, which aligns with findings from prior studies indicating root canal volume increases ranging from 1.33 to 2.77 mm3 using the ProTaper Gold® system (Dentsply Sirona)
DISCUSSION 85 system (Duque et al., 2017; Gagliardi et al., 2015; Martins et al., 2022; Silva et al., 2021). Nevertheless, all these studies were conducted in mesial canals of mandibular molars. It has been demonstrated that discrepancies in canal geometry prior to preparation may exert a more significant influence on the observed alterations than the preparation techniques alone (Peters et al., 2001). This could explain the disparities among study findings. The secondary aim was to evaluate the time and number of pecking movements required for root canal preparation using the ProTaper Gold® (Dentsply-Sirona) system, on TrueTooth® (DELabs) compared to natural teeth. The mean time of preparation for artificial teeth was one second less, and fewer pecking movements were required for canal preparation compared to natural teeth. However, there were no statistically significant differences between them. Hence, the null hypothesis was accepted. These findings suggest that despite artificial teeth requiring less time and fewer pecking movements for preparation, possibly due to variations in hardness between resin and human dentin (Al- Sudani & Basudan, 2017; Hulsmann, 2022; Reymus et al., 2020), no statistically significant differences were observed. Consequently, the null hypothesis was accepted. This outcome aligns with the findings of Luz et al. (2015), who compared preparation times between natural and artificial teeth using hand-files among students and specialists. Their study concluded that the preparation time for artificial teeth was consistently shorter than for natural teeth across both groups (Luz et al., 2015). The average preparation time for natural teeth using the ProTaper Gold® (Dentsply- Sirona) system was recorded at 64.3 seconds. This duration is shorter compared to the findings of Arslan et al. (2017), in which the mean preparation time was 78 seconds, however, the absence of information regarding whether the glyde path was established manually or mechanically, or whether it was established at all, was not addressed by the authors (Arslan et al., 2017). This discrepancy between the two studies’ results could potentially be attributed to methodological differences. Literature suggests that a mechanically established glyde path tends to be swifter than a manual one (Paleker & van der Vyver, 2017; Zheng et al., 2018). Additionally, if a glyde path is omitted, the root preparation duration is likely to be prolonged (Kirici et al., 2020). Yamada et al. (2023) documented a preparation time of 43.46 seconds when dealing with "J" canals in resin clear blocks using the ProTaper Gold® (Dentsply-Sirona) (Yamada et al., 2023). Nevertheless, the time needed for preparing this canal type is notably shorter compared to both natural and artificial teeth (Luz et al., 2015). In Bitter et al. study (2016), 43 students were divided into two groups: one group trained exclusively on TrueTooth® (the test group), while the other group trained on natural teeth (the control group). Following a training period, both groups prepared a natural tooth and an artificial tooth, and their performance was assessed. The study concluded that students exclusively trained on artificial teeth did not demonstrate significantly different performance on natural teeth compared to those trained on natural teeth. However, overall, students tended to exhibit better performance on artificial teeth than on natural teeth (Bitter et al., 2016). Moreover, in Gancedo-Caravia et al. study (2020), students were tasked with conducting endodontic treatments on various commercially available artificial teeth, and their performance was subsequently evaluated by three proficient endodontic educators. The evaluation of artificial teeth encompassed three viewpoints: students’ achievements,
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 86 students’ perceptions, and educators’ perceptions. The educators concluded that replicas derived from microCT scans more accurately replicated internal anatomy, with TrueTooth® (DELabs) specifically identified as the optimal replica for training in access cavity preparation and negotiation. Conversely, students assessed and performed less proficiently on TrueTooth® (DELabs) likely due to its higher level of difficulty compared to artificial teeth (Gancedo-Caravia et al., 2020). The findings from these studies, along with those from the current research concerning preparation time and the number of pecking movements required for root canal preparation, suggest that TrueTooth® (DELabs) holds promise for endodontic training. Nonetheless, further investigations employing different preparation systems, diverse geometries, and different kinematics preparation movements are needed in the future. 6.2 DISCUSSION OF SECOND PRIMARY AIM The sencond primary aim was to describe a support material removal protocol and to compare root canal anatomy between a natural tooth and 3D printed teeth using Micro- CT scans of the natural tooth as a reference. Micro-CT, recognized for its non-invasive and non-destructive nature, enables the assessment of various parameters both pre- and post-preparation. It is widely regarded as the gold standard in root canal preparation research (Hulsmann, 2022). Upon comparing the volume and centroids X, Y, Z of the natural tooth with those of the 3D printed teeth prior to preparation, our results revealed no statistically significant differences between natural tooth and 3D printed teeth. As a result, the null hypothesis was accepted. These findings indicate that the described support material removal protocol is effective in eliminating the support material (SUP706B™) utilized in this study, and PolyJet® is suitable for producing 3D printed teeth with internal anatomy similar to that of natural teeth. The support material removal protocol outlined in this study is based on the manufacturer’s guidelines for removing the support material SUP706B™ through solubilization. This process involves the use of a 2% alkaline solution of sodium hydroxide and a 1% solution of sodium metasilicate in a cleaning station, followed by rinsing with water (Stratasys, 2019). Therefore, an alternative approach was developed, wherein sodium hydroxide serves as the primary component of the support material removal protocol. Additionally, Derquim® LM 01 alkalin detergent (ITW Reagents, S.R.L.), a general cleaning agent for laboratory use, containing sodium hydroxide (<5%) along with anionic and non-ionic surfactants (15-30%), was employed to facilitate cleaning action on the root canal walls, mimicking the detergent function of sodium metasilicate (ITWreagents, 2016). Sonic activation with Endoactivator® (Dentsply-Sirona) was employed to enhance the action of irrigants by generating intra-canal agitation and streaming. However, as the Endoactivator® (Dentsply-Sirona) Tip’s contact with the root canal walls hinders its free oscillation and diminishes irrigant streaming, the tip was positioned as deeply as possible without making contact with the walls (Donnermeyer et al., 2023; Jiang et al., 2010). However, even in the event of contact, the Endoactivator® (Dentsply-Sirona) Tip, being made of polyamide, does not actively cut the root canal, thereby reducing the risk of altering root canal anatomy (Haupt et al., 2020; Mathew et al., 2023).
DISCUSSION 87 The Irriflex® (Produits dentaires SA) needle utilized is a polyethylene flexible needle, which ensures smoother advancement within the canal without wedging against the root canal walls. It features two side openings that generate jets directed towards the root canal walls, facilitating the delivery of a substantial volume of irrigant at a high flow rate while minimizing the risk of apical extrusion (Provoost et al., 2022). However, for a support material removal protocol to be effective, irrigant extrusion is needed as stated in a previous study (Reymus et al., 2019), so irrigation must be carried out with high pressure and the needle tip positioned as close to the apex as posible. Nevertheless, the results show differences in the values of 3D printed teeth before preparation, indicating that these teeth are not uniform across all specimens. This can be a result of our protocol; where canal patency plays a crucial role in its efficacy, as evidenced by the visual observation of irrigant extrusion mentioned earlier. To ensure canal patency, a K-file #15 was selected for this purpose, given the challenges in removing support material in channels under 150µm (Macdonald et al., 2017), and it was required that the K-file be used five times for each canal. Following this designated number of uses, if patency was compromised, the K-file #15 was employed to restore it. Despite its passive utilization, this implies that the number of insertions of the K-file #15 varied among the canals and its effects on root canal anatomy should be considered (Hartmann et al., 2018; Smutny et al., 2022). Another concern that warrants attention is that, while PolyJet® printing technology has the smallest dimensional error among various 3D printing technologies (Herpel et al., 2021; Kim et al., 2022; Kim et al., 2018; Rouze l'Alzit et al., 2022), its accuracy is contingent upon factors such as the material utilized, the geometry of the printed object, and the orientation relative to both the printer head and printer bed (Bezek et al., 2016; Kent et al., 2017; Mendřický, 2016; Rouze l'Alzit et al., 2022). In a prior investigation, a rectangular flat part was printed with its long axis aligned parallel to either the X, Y, or Z axis of the printer bed. It was determined that for the strongest parts, the long axis of the printed part should be parallel to the X axis (Bezek et al., 2016). However, to the best of the author’s knowledge, this aspect has not been explored in the context of printing teeth. In the case of a single-root tooth, determining the long axis is straightforward, it aligns with the long axis of the root. However, in our study involving multi-rooted teeth, we measured the tooth as a whole, and the longest distance was observed in the buccal to palatal direction. Therefore, this was considered the long axis, and the 3D printed teeth were produced accordingly, as illustrated in Figure 3. Nevertheless, future studies should assess which is the best orientation to give a multiple root tooth according to the X, Y or Z axis and determine if this orientation significantly impacts the accuracy of 3D printed teeth. Furthermore, it has been documented that alterations in volume occur during PolyJet® printing due to expansion (Mendřický, 2016; Rebong et al., 2018). The results demonstrate a volume expansion of 0.77%, which could also account for the differences observed among 3D printed teeth. This finding aligns closely with the 0.71% expansion reported in a prior study (Lee et al., 2015).
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 88 Additionally, it’s worth noting that the STL file underwent simplification and preparation for 3D printing, which may have led to some degree of distortion (Lee et al., 2015). Future studies should assess the extent of simplification that STL files can undergo without causing significant distortion relatively to natural tooth. The natural tooth used had its crown sectioned and presented an internal anatomy with three single different types of canals, however it did not present any anatomical irregularities such as lateral canals or sthmuses, which are known to be challenging areas for irrigants’ access (Chan et al., 2023), future studies are needed to evaluate the effectiveness of the support material in teeth with full crown and with anatomical irregularities. Regarding the first secondary aim, in order 3D printed teeth to be used in ex vivo preparation studies, its behaviour to preparation should be similar to natural tooth, the present results regarding volume of dentin removed, percentage of volume increase, transportation, and unprepared areas, show that there were no statistically significant differences between them. Hence, the null hypothesis was accepted, leading to the conclusion that 3D printed teeth behave similarly to natural tooth when prepared with ProTaper Gold® (Dentsply-Sirona). Regarding the second secondary aim, to evaluate the time and number of pecking movements required for root canal preparation using the ProTaper Gold® (Dentsply- Sirona) system on natural tooth compared to 3D printed teeth, it was showed that 3D printed teeth required less preparation time and less pecking movements. However, there were no statistically significant differences between them. These findings align with our earlier research conducted on the preparation of TrueTooth® and are consistent with Luz et al. (2015) observations (Luz et al., 2015; Reis et al., 2023), that less time and fewer pecking movements are necessary for preparing tooth replicas compared to natural teeth, nonetheless without statistically significant differences between them. Hence, the null hypothesis was accepted, reinforcing the conclusion of the first secondary aim, that 3D printed teeth behave similarly to natural tooth when prepared with ProTaper Gold® (Dentsply-Sirona). The major concern raised regarding 3D printed teeth is the difference in hardness between resin and human dentin (Hulsmann, 2022; Karatekin et al., 2019; Kolling et al., 2021; Ordinola-Zapata et al., 2014; Reymus et al., 2019). The High Temperature RGD525™ is an opaque model material that has exceptional dimensional stability and presents a tensile strength ranging from 70 to 80 MPa, a modulus of elasticity ranging from 3200 to 3500 MPa, a flexural strength ranging from 110 to 130 MPa (Stratasys, 2022). In contrast, human dentin exhibits a tensile strength ranging from 44.4 to 97.8 MPa, with the lower value typically found in the inner dentin near the pulp (Staninec et al., 2002). Its modulus of elasticity falls between 1375 and 1931 MPa (Chun et al., 2014), and its flexural strength ranges from 171 to 254 MPa (Plotino et al., 2007). While the printing material and dentin exhibit comparable values, disparities in their structural organization persist due to dentin's tubular nature. Consequently, there is a necessity for the advancement of both printing materials and techniques to replicate the natural structure of teeth in 3D printed teeth.
BIBLIOGRAPHY 95 8. BIBLIOGRAPHY AAE. (2020). Glossary of endodontic terms. American Association of Endodontists. Retrieved 04/05/2022 from https://www.aae.org/specialty/clinicalresources/glossary-endodontic-terms/ Aazzouzi-Raiss, K., Ramirez-Munoz, A., Mendez, S. P., Vieira, G. C. S., Aranguren, J., & Perez, A. R. (2023). Effects of Conservative Access and Apical Enlargement on Shaping and Dentin Preservation with Traditional and Modern Instruments: A Micro-computed Tomographic Study. J Endod, 49(4), 430-437. https://doi.org/10.1016/j.joen.2023.01.004 Aksoy, U., Kucuk, M., Versiani, M. A., & Orhan, K. (2021). Publication trends in micro- CT endodontic research: a bibliometric analysis over a 25-year period. Int Endod J, 54(3), 343-353. https://doi.org/10.1111/iej.13433 Al-Sudani, D. I., & Basudan, S. O. (2017). Students' perceptions of pre-clinical endodontic training with artificial teeth compared to extracted human teeth. Eur J Dent Educ, 21(4), e72-e75. https://doi.org/10.1111/eje.12223 Alak, S. G., Keles, A., Keskin, C., Martins, J. N. R., & Versiani, M. A. (2023). Agerelated changes in the morphology of the root canal system of mandibular first molars: a micro-CT study. Clin Oral Investig, 27(8), 4667-4675. https://doi.org/10.1007/s00784-023-05093-0 Alberton, C. S., Tomazinho, F. S. F., Calefi, P. S., Duarte, M. A. H., Vivan, R. R., & Baratto-Filho, F. (2020). Influence of the Preparation Order in Four-Canal Maxillary Molars with WaveOne Gold System. J Endod, 46(9), 1291-1296. https://doi.org/10.1016/j.joen.2020.05.018 Alovisi, M., Cemenasco, A., Mancini, L., Paolino, D., Scotti, N., Bianchi, C. C., & Pasqualini, D. (2017). Micro-CT evaluation of several glide path techniques and ProTaper Next shaping outcomes in maxillary first molar curved canals. Int Endod J, 50(4), 387-397. https://doi.org/10.1111/iej.12628 Alqedairi, A., Alfawaz, H., Abualjadayel, B., Alanazi, M., Alkhalifah, A., & Jamleh, A. (2019). Torsional resistance of three ProTaper rotary systems. BMC Oral Health, 19(1), 124. https://doi.org/10.1186/s12903-019-0820-7 Anderson, J., Wealleans, J., & Ray, J. (2018). Endodontic applications of 3D printing. Int Endod J, 51(9), 1005-1018. https://doi.org/10.1111/iej.12917 Arias, A., & Peters, O. A. (2022). Present status and future directions: Canal shaping. Int Endod J, 55 Suppl 3(Suppl 3), 637-655. https://doi.org/10.1111/iej.13698
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 96 Arola, D. D., Gao, S., Zhang, H., & Masri, R. (2017). The Tooth: Its Structure and Properties. Dent Clin North Am, 61(4), 651-668. https://doi.org/10.1016/j.cden.2017.05.001 Arslan, H., Yildiz, E. D., Gunduz, H. A., Sumbullu, M., Bayrakdar, I. S., Karatas, E., & Sumbullu, M. A. (2017). Comparative study of ProTaper gold, reciproc, and ProTaper universal for root canal preparation in severely curved root canals. J Conserv Dent, 20(4), 222-224. https://doi.org/10.4103/JCD.JCD_94_17 Betti, L. V., & Bramante, C. M. (2001). Quantec SC rotary instruments versus hand files for gutta-percha removal in root canal retreatment. Int Endod J, 34(7), 514-519. https://doi.org/10.1046/j.1365-2591.2001.00424.x Bezek, L., Meisel, N., & Williams, C. (2016). Exploring variability of orientation and aging effects in material properties of multi-material jetting parts. Rapid Prototyping Journal, 22, 826-834. https://doi.org/10.1108/RPJ-11-2015-0169 Bitter, K., Gruner, D., Wolf, O., & Schwendicke, F. (2016). Artificial Versus Natural Teeth for Preclinical Endodontic Training: A Randomized Controlled Trial. J Endod, 42(8), 1212-1217. https://doi.org/10.1016/j.joen.2016.05.020 Buchanan, L. S. (2014, 2014). Control the anatomy; control procedural training. Roots the international CE magazine of endodontics, 5(2), 14-18. Byun, C., Kim, C., Cho, S., Baek, S. H., Kim, G., Kim, S. G., & Kim, S. Y. (2015). Endodontic Treatment of an Anomalous Anterior Tooth with the Aid of a 3- dimensional Printed Physical Tooth Model. J Endod, 41(6), 961-965. https://doi.org/10.1016/j.joen.2015.01.016 Castelo-Baz, P., Gancedo-Gancedo, T., Pereira-Lores, P., Mosquera-Barreiro, C., Martin- Biedma, B., Faus-Matoses, V., & Ruiz-Pinon, M. (2023). Conservative management of dens in dente. Aust Endod J, 49 Suppl 1, 481-487. https://doi.org/10.1111/aej.12763 Chan, C. W., Romeo, V. R., Lee, A., Zhang, C., Neelakantan, P., & Pedulla, E. (2023). Accumulated Hard Tissue Debris and Root Canal Shaping Profiles Following Instrumentation with Gentlefile, One Curve, and Reciproc Blue. J Endod, 49(10), 1344-1351. https://doi.org/10.1016/j.joen.2023.07.019 Choi, M. J., Kim, M. A., Choi, Y., Neelakantan, P., Yu, M. K., & Min, K. S. (2021). A novel three-dimensionally printed model to assess biofilm removal by ultrasonically activated irrigation. Int Endod J, 54(10), 1871-1877. https://doi.org/10.1111/iej.13579 Chun, K., Choi, H., & Lee, J. (2014). Comparison of mechanical property and role between enamel and dentin in the human teeth. J Dent Biomech, 5, 1758736014520809. https://doi.org/10.1177/1758736014520809
BIBLIOGRAPHY 97 Cresswell-Boyes, A. J., Davis, G. R., Krishnamoorthy, M., Mills, D., & Barber, A. H. (2022). Composite 3D printing of biomimetic human teeth. Sci Rep, 12(1), 7830. https://doi.org/10.1038/s41598-022-11658-y Cui, Z., Wei, Z., Du, M., Yan, P., & Jiang, H. (2018). Shaping ability of protaper next compared with waveone in late-model three-dimensional printed teeth. BMC Oral Health, 18(1), 115. https://doi.org/10.1186/s12903-018-0573-8 Curylofo-Zotti, F. A., Lorencetti-Silva, F., de Almeida Coelho, J., Monteiro, R. M., Watanabe, E., & Corona, S. A. M. (2018). Human teeth biobank: Microbiological analysis of the teeth storage solution. Microsc Res Tech, 81(3), 332-337. https://doi.org/10.1002/jemt.22984 Dablanca-Blanco, A. B., Castelo-Baz, P., Miguens-Vila, R., Alvarez-Novoa, P., & Martin-Biedma, B. (2022). Endodontic Rotary Files, What Should an Endodontist Know? Medicina (Kaunas), 58(6). https://doi.org/10.3390/medicina58060719 Dablanca‐Blanco, A., Arias, A., Ginzo Villamayor, M., Pérez, M., Castelo, P., & Martin- Biedma, B. (2021). Influence of operator expertise on glide path and root canal preparation of curved root canals with rotary and reciprocating motions. Australian Endodontic Journal, 48. https://doi.org/10.1111/aej.12585 De-Deus, G. (2012). Research that matters - root canal filling and leakage studies. Int Endod J, 45(12), 1063-1064. https://doi.org/10.1111/j.1365-2591.2012.02104.x De-Deus, G., Rodrigues, E. A., Lee, J. K., Kim, J., Silva, E., Belladonna, F. G., Simoes- Carvalho, M., Souza, E. M., & Versiani, M. A. (2023). Taper 0.06 Versus Taper 0.04: The Impact on the Danger Zone. J Endod, 49(5), 536-543. https://doi.org/10.1016/j.joen.2023.02.009 De-Deus, G., Simoes-Carvalho, M., Belladonna, F. G., Versiani, M. A., Silva, E., Cavalcante, D. M., Souza, E. M., Johnsen, G. F., Haugen, H. J., & Paciornik, S. (2020). Creation of well-balanced experimental groups for comparative endodontic laboratory studies: a new proposal based on micro-CT and in silico methods. Int Endod J, 53(7), 974-985. https://doi.org/10.1111/iej.13288 Decurcio, D. A., Lim, E., Chaves, G. S., Nagendrababu, V., Estrela, C., & Rossi-Fedele, G. (2019). Pre-clinical endodontic education outcomes between artificial versus extracted natural teeth: a systematic review. Int Endod J, 52(8), 1153-1161. https://doi.org/10.1111/iej.13116 DELabs. TrueTooth Catalog. Retrieved 28/02/2021 from https://online.fliphtml5.com/tfwec/famt/#p=15 Dobros, K., Hajto-Bryk, J., & Zarzecka, J. (2022). Application of 3D-printed teeth models in teaching dentistry students: A scoping review. Eur J Dent Educ. https://doi.org/10.1111/eje.12784
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 98 Donnermeyer, D., Averkorn, C., Burklein, S., & Schafer, E. (2023). Cleaning Efficiency of Different Irrigation Techniques in Simulated Severely Curved Complex Root Canal Systems. J Endod. https://doi.org/10.1016/j.joen.2023.08.006 Drukteinis, S., Peciuliene, V., Dummer, P. M. H., & Hupp, J. (2019). Shaping ability of BioRace, ProTaper NEXT and Genius nickel-titanium instruments in curved canals of mandibular molars: a MicroCT study. Int Endod J, 52(1), 86-93. https://doi.org/10.1111/iej.12961 du Plessis, A., & Broeckhoven, C. (2019). Looking deep into nature: A review of microcomputed tomography in biomimicry. Acta Biomater, 85, 27-40. https://doi.org/10.1016/j.actbio.2018.12.014 du Plessis, A., Broeckhoven, C., Guelpa, A., & le Roux, S. G. (2017). Laboratory x-ray micro-computed tomography: a user guideline for biological samples. Gigascience, 6(6), 1-11. https://doi.org/10.1093/gigascience/gix027 Du Plessis, A., Yadroitsev, I., Yadroitsava, I., & Le Roux, S. (2018). X-Ray Microcomputed Tomography in Additive Manufacturing: A Review of the Current Technology and Applications. 3D Printing and Additive Manufacturing, 5. https://doi.org/10.1089/3dp.2018.0060 Duque, J. A., Vivan, R. R., Cavenago, B. C., Amoroso-Silva, P. A., Bernardes, R. A., Vasconcelos, B. C., & Duarte, M. A. (2017). Influence of NiTi alloy on the root canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems. J Appl Oral Sci, 25(1), 27-33. https://doi.org/10.1590/1678- 77572016-0230 Duque, J. A., Vivan, R. R., Duarte, M. A. H., Alcalde, M. P., Cruz, V. M., Borges, M. M. B., & Bramante, C. M. (2019). Effect of larger apical size on the quality of preparation in curved canals using reciprocating instruments with different heat thermal treatments. Int Endod J, 52(11), 1652-1659. https://doi.org/10.1111/iej.13165 Elashiry, M. M., Saber, S. E., & Elashry, S. H. (2020). Comparison of Shaping Ability of Different Single-File Systems Using Microcomputed Tomography. Eur J Dent, 14(1), 70-76. https://doi.org/10.1055/s-0040-1701393 Elnaghy, A. M., & Elsaka, S. E. (2016). Mechanical properties of ProTaper Gold nickeltitanium rotary instruments. Int Endod J, 49(11), 1073-1078. https://doi.org/10.1111/iej.12557 Endogal. Endogal Catalogo. Endogal. Retrieved 28/10/2021 from https://endogal.es/wpcontent/uploads/2020/04/Endogal-Cata%CC%81logo-2020.pdf ESE. (2006). Quality guidelines for endodontic treatment: consensus report of the European Society of Endodontology. Int Endod J, 39(12), 921-930. https://doi.org/10.1111/j.1365-2591.2006.01180.x
BIBLIOGRAPHY 99 Fahad, M., Dickens, P., & Gilbert, M. (2013). Novel polymeric support materials for jetting based additive manufacturing processes. Rapid Prototyping Journal, 19(4), 230-239. https://doi.org/10.1108/13552541311323245 Fakhr, M., & Nagy, M. M. (2023). Three-Dimensional tooth models for better teaching and treatment outcomes. Eur J Dent Educ, 27(3), 695-699. https://doi.org/10.1111/eje.12857 Faus-Matoses, V., Faus-Llacer, V., Ruiz-Sanchez, C., Jaramillo-Vasconez, S., Faus- Matoses, I., Martin-Biedma, B., & Zubizarreta-Macho, A. (2022). Effect of Rotational Speed on the Resistance of NiTi Alloy Endodontic Rotary Files to Cyclic Fatigue-An In Vitro Study. J Clin Med, 11(11). https://doi.org/10.3390/jcm11113143 Fernandes, P. O. F., Freire, L. G., Iglecias, E. F., Vieira, B. R., Zuolo, M. L., & Gavini, G. (2020). Assessment of Mechanical Root Canal Preparation with Centric Reciprocating or Eccentric Rotary Kinematics: A Micro-computed Tomographic Study. J Endod, 46(9), 1309-1316. https://doi.org/10.1016/j.joen.2020.06.005 Fidler, A., Plotino, G., & Kuralt, M. (2021). A Critical Review of Methods for Quantitative Evaluation of Root Canal Transportation. J Endod, 47(5), 721-731. https://doi.org/10.1016/j.joen.2021.02.002 Gagliardi, J., Versiani, M. A., de Sousa-Neto, M. D., Plazas-Garzon, A., & Basrani, B. (2015). Evaluation of the Shaping Characteristics of ProTaper Gold, ProTaper NEXT, and ProTaper Universal in Curved Canals. J Endod, 41(10), 1718-1724. https://doi.org/10.1016/j.joen.2015.07.009 Gambarini, G., Seracchiani, M., Testarelli, L., Miccoli, G., Di Nardo, D., Obino, F., Galli, M., & Cicconetti, A. (2021). Operative Torque Analysis to Evaluate Cutting Efficiency of Two Nickel-Titanium Rotary Instruments for Glide Path: An In Vitro Comparison. The Journal of Contemporary Dental Practice, 22, 215-218. https://doi.org/10.5005/jp-journals-10024-3061 Gancedo-Caravia, L., Bascones, J., Garcia-Barbero, E., & Arias, A. (2020). Suitability of different tooth replicas for endodontic training: perceptions and detection of common errors in the performance of postgraduate students. Int Endod J, 53(4), 562-572. https://doi.org/10.1111/iej.13251 Ghavami-Lahiji, M., Davalloo, R. T., Tajziehchi, G., & Shams, P. (2021). Microcomputed tomography in preventive and restorative dental research: A review. Imaging Sci Dent, 51(4), 341-350. https://doi.org/10.5624/isd.20210087 Gok, T., Capar, I. D., Akcay, I., & Keles, A. (2017). Evaluation of Different Techniques for Filling Simulated C-shaped Canals of 3-dimensional Printed Resin Teeth. J Endod, 43(9), 1559-1564. https://doi.org/10.1016/j.joen.2017.04.029 Gomes, I. L. L., Alves, F. R. F., Marceliano-Alves, M. F., Silveira, S. B., Provenzano, J. C., & Goncalves, L. S. (2021). Canal transportation using Mani GPR or HyFlex
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 100 NT during the retreatment of curved root canals: A micro-computed tomographic study. Aust Endod J, 47(1), 73-80. https://doi.org/10.1111/aej.12470 Grande, N., Plotino, G., Butti, A., & Buono, L. (2005). Modern endodontic NiTi systems: Morphological and technical characteristics part I: «New generation» NiTi systems. Endod Ther, 5, 11-16. Grande, N. M., Plotino, G., Silla, E., Pedulla, E., DeDeus, G., Gambarini, G., & Somma, F. (2017). Environmental Temperature Drastically Affects Flexural Fatigue Resistance of Nickel-titanium Rotary Files. J Endod, 43(7), 1157-1160. https://doi.org/10.1016/j.joen.2017.01.040 Guldberg, R. E., Ballock, R. T., Boyan, B. D., Duvall, C. L., Lin, A. S., Nagaraja, S., Oest, M., Phillips, J., Porter, B. D., Robertson, G., & Taylor, W. R. (2003). Analyzing bone, blood vessels, and biomaterials with microcomputed tomography. IEEE Eng Med Biol Mag, 22(5), 77-83. https://doi.org/10.1109/memb.2003.1256276 Ha, J. H., Kwak, S. W., Sigurdsson, A., Chang, S. W., Kim, S. K., & Kim, H. C. (2017). Stress Generation during Pecking Motion of Rotary Nickel-titanium Instruments with Different Pecking Depth. J Endod, 43(10), 1688-1691. https://doi.org/10.1016/j.joen.2017.04.013 Ha, J. H., & Park, S. S. (2012). Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals. Restor Dent Endod, 37(4), 215-219. https://doi.org/10.5395/rde.2012.37.4.215 Hanafi, A., Donnermeyer, D., Schafer, E., & Burklein, S. (2020). Perception of a modular 3D print model in undergraduate endodontic education. Int Endod J, 53(7), 1007- 1016. https://doi.org/10.1111/iej.13299 Hartmann, R. C., Peters, O. A., de Figueiredo, J. A. P., & Rossi-Fedele, G. (2018). Association of manual or engine-driven glide path preparation with canal centring and apical transportation: a systematic review. Int Endod J, 51(11), 1239-1252. https://doi.org/10.1111/iej.12943 Haupt, F., Meinel, M., Gunawardana, A., & Hulsmann, M. (2020). Effectiveness of different activated irrigation techniques on debris and smear layer removal from curved root canals: a SEM evaluation. Aust Endod J, 46(1), 40-46. https://doi.org/10.1111/aej.12342 Herpel, C., Tasaka, A., Higuchi, S., Finke, D., Kuhle, R., Odaka, K., Rues, S., Lux, C. J., Yamashita, S., Rammelsberg, P., & Schwindling, F. S. (2021). Accuracy of 3D printing compared with milling - A multi-center analysis of try-in dentures. J Dent, 110, 103681. https://doi.org/10.1016/j.jdent.2021.103681 Hieawy, A., Haapasalo, M., Zhou, H., Wang, Z. J., & Shen, Y. (2015). Phase Transformation Behavior and Resistance to Bending and Cyclic Fatigue of ProTaper Gold and ProTaper Universal Instruments. J Endod, 41(7), 1134-1138. https://doi.org/10.1016/j.joen.2015.02.030
BIBLIOGRAPHY 101 Hilaly Eid, G. E., & Wanees Amin, S. A. (2011). Changes in diameter, cross-sectional area, and extent of canal-wall touching on using 3 instrumentation techniques in long-oval canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 112(5), 688-695. https://doi.org/10.1016/j.tripleo.2011.05.007 Holden, A., & Dracopoulos, S. A. (2017). Owning the tooth: exploring the ethical and legal issues relating to the use of extracted human teeth in dental education in Australia. Aust Dent J, 62(2), 146-151. https://doi.org/10.1111/adj.12493 Hope, C. K., Griffiths, D. A., & Prior, D. M. (2013). Finding an alternative to formalin for sterilization of extracted teeth for teaching purposes. J Dent Educ, 77(1), 68- 71. https://www.ncbi.nlm.nih.gov/pubmed/23314468 Hulsmann, M. (2022). A critical appraisal of research methods and experimental models for studies on root canal preparation. Int Endod J, 55 Suppl 1, 95-118. https://doi.org/10.1111/iej.13665 Hülsmann, M., Peters, O. A., & Dummer, P. M. H. (2005). Mechanical preparation of root canals: shaping goals, techniques and means. Endodontic Topics, 10(1), 30- 76. https://doi.org/10.1111/j.1601-1546.2005.00152.x ISO/ASTM. (2021). 52:900:2021. ITWreagents. (2016). Technical Data Sheet. Retrieved 22/07/2022 from https://www.itwreagents.com/download_file/tds/502600/en/tds_502600_en.pdf Ivancik, J., Naranjo, M., Correa, S., Ossa, A., Tay, F. R., Pashley, D. H., & Arola, D. (2014). Differences in the microstructure and fatigue properties of dentine between residents of North and South America. Arch Oral Biol, 59(10), 1001- 1012. https://doi.org/10.1016/j.archoralbio.2014.05.028 Jiang, L. M., Verhaagen, B., Versluis, M., & van der Sluis, L. W. (2010). Evaluation of a sonic device designed to activate irrigant in the root canal. J Endod, 36(1), 143- 146. https://doi.org/10.1016/j.joen.2009.06.009 Johnsen, G. F., Dara, S., Asjad, S., Sunde, P. T., & Haugen, H. J. (2017). Anatomic Comparison of Contralateral Premolars. J Endod, 43(6), 956-963. https://doi.org/10.1016/j.joen.2017.01.012 Johnsen, G. F., Sunde, P. T., & Haugen, H. J. (2018). Validation of contralateral premolars as the substrate for endodontic comparison studies. Int Endod J, 51(8), 942-951. https://doi.org/10.1111/iej.12902 Karatekin, A. O., Keles, A., & Gencoglu, N. (2019). Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM. PLoS One, 14(11), e0224793. https://doi.org/10.1371/journal.pone.0224793
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 102 Kent, N. J., Jolivet, L., O’Neill, P., & Brabazon, D. (2017). An evaluation of components manufactured from a range of materials, fabricated using PolyJet technology. Advances in Materials and Processing Technologies, 3(3), 318-329. https://doi.org/10.1080/2374068X.2017.1330856 Keskin, C., Sivas Yilmaz, O., & Inan, U. (2020). Apically extruded debris produced during glide path preparation using R-Pilot, WaveOne Gold Glider and ProGlider in curved root canals. Aust Endod J, 46(3), 439-444. https://doi.org/10.1111/aej.12428 Kessler, A., Hickel, R., & Reymus, M. (2020). 3D Printing in Dentistry-State of the Art. Oper Dent, 45(1), 30-40. https://doi.org/10.2341/18-229-L Kim, G. B., Lee, S., Kim, H., Yang, D. H., Kim, Y. H., Kyung, Y. S., Kim, C. S., Choi, S. H., Kim, B. J., Ha, H., Kwon, S. U., & Kim, N. (2016). Three-Dimensional Printing: Basic Principles and Applications in Medicine and Radiology. Korean J Radiol, 17(2), 182-197. https://doi.org/10.3348/kjr.2016.17.2.182 Kim, J. H., Pinhata-Baptista, O. H., Ayres, A. P., da Silva, R. L. B., Lima, J. F., Urbano, G. S., No-Cortes, J., Vasques, M. T., & Cortes, A. R. G. (2022). Accuracy Comparison among 3D-Printing Technologies to Produce Dental Models. Applied Sciences, 12(17), 8425. https://doi.org/doi.org/10.3390/app12178425 Kim, S. Y., Shin, Y. S., Jung, H. D., Hwang, C. J., Baik, H. S., & Cha, J. Y. (2018). Precision and trueness of dental models manufactured with different 3- dimensional printing techniques. Am J Orthod Dentofacial Orthop, 153(1), 144- 153. https://doi.org/10.1016/j.ajodo.2017.05.025 Kimura, S., Ebihara, A., Maki, K., Nishijo, M., Tokita, D., & Okiji, T. (2020). Effect of Optimum Torque Reverse Motion on Torque and Force Generation during Root Canal Instrumentation with Crown-down and Single-length Techniques. J Endod, 46(2), 232-237. https://doi.org/10.1016/j.joen.2019.11.007 Kirchhoff, A. L., Chu, R., Mello, I., Garzon, A. D., dos Santos, M., & Cunha, R. S. (2015). Glide Path Management with Single- and Multiple-instrument Rotary Systems in Curved Canals: A Micro-Computed Tomographic Study. J Endod, 41(11), 1880- 1883. https://doi.org/10.1016/j.joen.2015.07.014 Kirici, D., Koc, S., & Kustarci, A. (2020). Effects of different glide path techniques on the amount of extruded debris and preparation times during root canal preparation. J Dent Res Dent Clin Dent Prospects, 14(3), 187-190. https://doi.org/10.34172/joddd.2020.031 Kolling, M., Backhaus, J., Hofmann, N., Kess, S., Krastl, G., Soliman, S., & Konig, S. (2021). Students' perception of three-dimensionally printed teeth in endodontic training. Eur J Dent Educ. https://doi.org/10.1111/eje.12743 Kroger, E., Dekiff, M., & Dirksen, D. (2017). 3D printed simulation models based on real patient situations for hands-on practice. Eur J Dent Educ, 21(4), e119-e125. https://doi.org/10.1111/eje.12229
BIBLIOGRAPHY 103 Kulczyk, T., Rychlik, M., Lorkiewicz-Muszynska, D., Abreu-Glowacka, M., Czajka- Jakubowska, A., & Przystanska, A. (2019). Computed Tomography versus Optical Scanning: A Comparison of Different Methods of 3D Data Acquisition for Tooth Replication. Biomed Res Int, 2019, 4985121. https://doi.org/10.1155/2019/4985121 Kumar, P., Sequeira, P., Peter, S., & Bhat K, G. (2005). Sterilisation of extracted human teeth for educational use. Indian journal of medical microbiology, 23, 256-258. https://doi.org/10.1016/S0255-0857(21)02532-9 Kyaw, M. S., Ebihara, A., Kasuga, Y., Maki, K., Kimura, S., Htun, P. H., Nakatsukasa, T., & Okiji, T. (2021). Influence of rotational speed on torque/force generation and shaping ability during root canal instrumentation of extracted teeth with continuous rotation and optimum torque reverse motion. Int Endod J, 54(9), 1614- 1622. https://doi.org/10.1111/iej.13485 Lacerda, M., Marceliano-Alves, M. F., Perez, A. R., Provenzano, J. C., Neves, M. A. S., Pires, F. R., Goncalves, L. S., Rocas, I. N., & Siqueira, J. F., Jr. (2017). Cleaning and Shaping Oval Canals with 3 Instrumentation Systems: A Correlative Microcomputed Tomographic and Histologic Study. J Endod, 43(11), 1878-1884. https://doi.org/10.1016/j.joen.2017.06.032 Lee, K. Y., Cho, J. W., Chang, N. Y., Chae, J. M., Kang, K. H., Kim, S. C., & Cho, J. H. (2015). Accuracy of three-dimensional printing for manufacturing replica teeth. Korean J Orthod, 45(5), 217-225. https://doi.org/10.4041/kjod.2015.45.5.217 Li, X., An, B., & Zhang, D. (2015). Determination of elastic and plastic mechanical properties of dentin based on experimental and numerical studies. Applied Mathematics and Mechanics, 36(10), 1347-1358. https://doi.org/10.1007/s10483- 015-1987-9 Liang, X., Liao, W., Cai, H., Jiang, S., & Chen, S. (2018). 3D-Printed Artificial Teeth: Accuracy and Application in Root Canal Therapy. J Biomed Nanotechnol, 14(8), 1477-1485. https://doi.org/10.1166/jbn.2018.2599 Liang, Y., & Yue, L. (2022). Evolution and development: engine-driven endodontic rotary nickel-titanium instruments. Int J Oral Sci, 14(1), 12. https://doi.org/10.1038/s41368-021-00154-0 Lugassy, D., Awad, M., Shely, A., Davidovitch, M., Pilo, R., & Brosh, T. (2021). 3D- Printed Teeth with Multicolored Layers as a Tool for Evaluating Cavity Preparation by Dental Students. Applied Sciences, 11(14), 6406. https://doi.org/10.3390/app11146406 Lui, K., Liu, H., Wang, H., Yang, X., Huang, D., Zhou, X., Gao, Y., & Shen, Y. (2023). An application framework of 3D assessment image registration accuracy and untouched surface area in canal instrumentation laboratory research with microcomputed tomography. Clin Oral Investig, 27(2), 715-725. https://doi.org/10.1007/s00784-022-04819-w
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 104 Luz, D., Ourique, F., Scarparo, R., Vier-Pelisser, F., Morgental, R., Waltrick, S., & Figueiredo, J. A. (2015). Preparation Time and Perceptions of Brazilian Specialists and Dental Students Regarding Simulated Root Canals for Endodontic Teaching: A Preliminary Study. Journal of dental education, 79, 56-63. https://doi.org/10.1002/j.0022-0337.2015.79.1.tb05857.x Macdonald, N. P., Cabot, J. M., Smejkal, P., Guijt, R. M., Paull, B., & Breadmore, M. C. (2017). Comparing Microfluidic Performance of Three-Dimensional (3D) Printing Platforms. Anal Chem, 89(7), 3858-3866. https://doi.org/10.1021/acs.analchem.7b00136 Marroquin, B. B., El-Sayed, M. A., & Willershausen-Zonnchen, B. (2004). Morphology of the physiological foramen: I. Maxillary and mandibular molars. J Endod, 30(5), 321-328. https://doi.org/10.1097/00004770-200405000-00005 Martins, J. N. R., Silva, E., Marques, D., Belladonna, F. G., Simoes-Carvalho, M., da Costa, R. P., Ginjeira, A., Braz Fernandes, F. M., & Versiani, M. A. (2022). Comparison of five rotary systems regarding design, metallurgy, mechanical performance, and canal preparation-a multimethod research. Clin Oral Investig, 26(3), 3299-3310. https://doi.org/10.1007/s00784-021-04311-x Mathew, D. M., Durvasulu, A., Shanmugam, S., & Pradeepkumar, A. R. (2023). Evaluation of Different Agitation Techniques on Smear Layer Formation and Dentine Erosions- An In Vitro Study. Eur Endod J, 8(1), 72-78. https://doi.org/10.14744/eej.2022.55477 Mello, I., Michaud, P. L., & Tanner, N. (2020). Resistance to fracture of extracted teeth used for pre-clinical endodontic procedures: Influence of storage conditions. Eur J Dent Educ, 24(2), 272-275. https://doi.org/10.1111/eje.12494 Mendřický, R. (2016). Accuracy analysis of additive technique for parts manufacturing. MM Science Journal, 2016, 1502-1508. https://doi.org/10.17973/MMSJ.2016_11_2016169 Michaud, P. L., Maleki, M., & Mello, I. (2018). Effect of Different Disinfection/Sterilization Methods on Risk of Fracture of Teeth Used in Preclinical Dental Education. J Dent Educ, 82(1), 84-87. https://doi.org/10.21815/JDE.018.012 Michetti, J., Basarab, A., Diemer, F., & Kouame, D. (2017). Comparison of an adaptive local thresholding method on CBCT and microCT endodontic images. Phys Med Biol, 63(1), 015020. https://doi.org/10.1088/1361-6560/aa90ff Montoya, C., Arango-Santander, S., Pelaez-Vargas, A., Arola, D., & Ossa, E. A. (2015). Effect of aging on the microstructure, hardness and chemical composition of dentin. Arch Oral Biol, 60(12), 1811-1820. https://doi.org/10.1016/j.archoralbio.2015.10.002
BIBLIOGRAPHY 111 Verdelis, K., & Salmon, P. (2019). Microcomputed Tomography Imaging in Odontogenesis Studies. Methods Mol Biol, 1922, 309-324. https://doi.org/10.1007/978-1-4939-9012-2_28 Versiani, M. A., & Keleș, A. (2020). Applications of Micro-CT Technology in Endodontics. In K. Orhan (Ed.), Micro-computed Tomography (micro-CT) in Medicine and Engineering (pp. 183-211). Springer International Publishing. https://doi.org/10.1007/978-3-030-16641-0_12 Versiani, M. A., Leoni, G. B., Steier, L., De-Deus, G., Tassani, S., Pecora, J. D., & de Sousa-Neto, M. D. (2013). Micro-computed tomography study of oval-shaped canals prepared with the self-adjusting file, Reciproc, WaveOne, and ProTaper universal systems. J Endod, 39(8), 1060-1066. https://doi.org/10.1016/j.joen.2013.04.009 Versiani, M. A., Pecora, J. D., & de Sousa-Neto, M. D. (2012). Root and root canal morphology of four-rooted maxillary second molars: a micro-computed tomography study. J Endod, 38(7), 977-982. https://doi.org/10.1016/j.joen.2012.03.026 Versiani, M. A., Pecora, J. D., & Sousa-Neto, M. D. (2013). Microcomputed tomography analysis of the root canal morphology of single-rooted mandibular canines. Int Endod J, 46(9), 800-807. https://doi.org/10.1111/iej.12061 Walker, M., & Humphries, S. (2019). 3D Printing: Applications in evolution and ecology. Ecol Evol, 9(7), 4289-4301. https://doi.org/10.1002/ece3.5050 Wang, L., Lin, R., Chen, H., Li, Z., Tay, F. R., & Gu, L. (2022). Influence of the Number of Pecking Motions at Working Length on the Shaping Ability of Single-file Systems in Long Oval-shaped Curved Canals. J Endod, 48(4), 548-554. https://doi.org/10.1016/j.joen.2022.01.009 Wu, M. K., R'Oris, A., Barkis, D., & Wesselink, P. R. (2000). Prevalence and extent of long oval canals in the apical third. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 89(6), 739-743. https://doi.org/10.1067/moe.2000.106344 Xu, F., Zhang, Y., Gu, Y., Ping, Y., Zhou, R., & Wang, J. (2021). Shaping ability of four single-file systems in the instrumentation of second mesiobuccal canals of threedimensional printed maxillary first molars. Ann Transl Med, 9(18), 1425. https://doi.org/10.21037/atm-21-3855 Xu, J., Shao, M. Y., Pan, H. Y., Lei, L., Liu, T., Cheng, L., Hu, T., & Dummer, P. M. (2016). A proposal for using contralateral teeth to provide well-balanced experimental groups for endodontic studies. Int Endod J, 49(10), 1001-1008. https://doi.org/10.1111/iej.12553 Yalniz, H., Koohnavard, M., Oncu, A., Celikten, B., Orhan, A. I., & Orhan, K. (2021). Comparative evaluation of dentin volume removal and centralization of the root canal after shaping with the ProTaper Universal, ProTaper Gold, and One-Curve
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 112 instruments using micro-CT. J Dent Res Dent Clin Dent Prospects, 15(1), 47-52. https://doi.org/10.34172/joddd.2021.009 Yamada, M., Kasahara, N., Matsunaga, S., Inose, T., Iwasawa, H., Nakajima, R., Tamiya, Y., & Furusawa, M. (2023). Comparison of Shaping Ability between Nickeltitanium Hand Files and Nickel-titanium Rotary Files during Glide path. Operative Dentistry, Endodontology and Periodontology, 3(1), 52-58. https://doi.org/10.11471/odep.2023-006 Yan, W., Montoya, C., Oilo, M., Ossa, A., Paranjpe, A., Zhang, H., & Arola, D. (2017). Reduction in Fracture Resistance of the Root with Aging. J Endod, 43(9), 1494- 1498. https://doi.org/10.1016/j.joen.2017.04.020 Yekta-Michael, S. S., Färber, C. M., & Heinzel, A. (2021). Evaluation of new endodontic tooth models in clinical education from the perspective of students and demonstrators. BMC Med Educ, 21(1), 447. https://doi.org/10.1186/s12909-021- 02848-9 Yilmaz, B., Dincol, M. E., & Yalcin, T. Y. (2019). A bibliometric analysis of the 103 topcited articles in endodontics. Acta Odontol Scand, 77(8), 574-583. https://doi.org/10.1080/00016357.2019.1621378 Zanza, A., D'Angelo, M., Reda, R., Gambarini, G., Testarelli, L., & Di Nardo, D. (2021). An Update on Nickel-Titanium Rotary Instruments in Endodontics: Mechanical Characteristics, Testing and Future Perspective-An Overview. Bioengineering (Basel), 8(12). https://doi.org/10.3390/bioengineering8120218 Zanza, A., Russo, P., Di Matteo, P., Reda, R., Di Nardo, D., Gambarini, G., & Testarelli, L. (2022). Mechanical properties and metallurgical features of two similar endodontic rotary instruments with different heat treatments (FireWire and Gold). Sci Prog, 105(2), 368504221103763. https://doi.org/10.1177/00368504221103763 Zheng, L., Ji, X., Li, C., Zuo, L., & Wei, X. (2018). Comparison of glide paths created with K-files, PathFiles, and the ProGlider file, and their effects on subsequent WaveOne preparation in curved canals. BMC Oral Health, 18(1), 152. https://doi.org/10.1186/s12903-018-0614-3 Zhu, Q., Liu, C., Bai, B., Pei, F., Tang, Y., Song, W., Chen, X., & Gu, Y. (2024). Microcomputed tomographic evaluation of the shaping ability of three nickel-titanium rotary systems in the middle mesial canal of mandibular first molars: an ex vivo study based on 3D printed tooth replicas. BMC Oral Health, 24(1), 294. https://doi.org/10.1186/s12903-024-04024-z Zupanc, J., Vahdat-Pajouh, N., & Schafer, E. (2018). New thermomechanically treated NiTi alloys - a review. Int Endod J, 51(10), 1088-1103. https://doi.org/10.1111/iej.12924
9. FIGURES INDEX
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 114 9. FIGURES INDEX Figure 1. 3D printing process ………………………………………………………… 50 Figure 2. Cross-sectional views of micro-CT scan of the natural tooth ………………. 65 Figure 3. Teeth orientation on the printer bed ………………………………………… 66 Figure 4. Flowchart of support material removal protocol …………………………… 67 Figure 5. Natural tooth (A) and 3D printed teeth (B and C) from different views …… 68 Figure 6. Artificial tooth mesiobuccal root before preparation: (A) raw image from micro- CT dataset; (B) image with threshold applied; (C) binarized black and white image; (D) histogram with selected values ………………………………………………………... 73 Figure 7. Artificial tooth mesiobuccal root after preparation: (A) raw image from micro- CT dataset; (B) image with threshold applied; (C) binarized black and white image; (D) histogram with selected values ……………………………………………………….. 73 Figure 8. Natural tooth mesiobuccal root before preparation: (A) raw image from micro- CT dataset; (B) image with threshold applied; (C) binarized black and white image; (D) histogram with selected values ……………………………………………………….. 73 Figure 9. Natural tooth mesiobuccal root after preparation: (A) raw image from micro- CT dataset; (B) image with threshold applied; (C) binarized black and white image; (D) histogram with selected values ………………………………………………………. 74 Figure 10. Representative 3D reconstruction of micro-CT scans before preparation from different views. (A) natural tooth, (B) 3D printed teeth of ProTaper Gold® (Dentsply- Sirona) group and (C) 3D printed teeth of Endogal® (Endogal, Galician endodontics Company) group ……………………………………………………………………… 76 Figure 11. Cross-sectional views of micro-CT scans before and after preparation. (A) natural tooth, (B) 3D printed teeth of ProTaper Gold® (Dentsply-Sirona) group and (C) 3D printed teeth of Endogal® (Endogal, Galician endodontics Company) group ……. 77 Figure 12. Representative 3D reconstruction of micro-CT scans before (green) and after (red) preparation from different views. (A) natural tooth, (B) 3D printed teeth of ProTaper Gold® (Dentsply-Sirona) group and (C) 3D printed teeth of Endogal® (Endogal, Galician endodontics Company) group …………………………………………………………. 79
10. TABLES INDEX
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 116 10. TABLES INDEX Table 1. Micro-CT analysis before and after preparation with ProTaper Gold® (Dentsply- Sirona) of artificial teeth mesiobuccal canal …………………………………………. 72 Table 2. Micro-CT analysis before and after preparation with ProTaper Gold® (Dentsply- Sirona) of natural teeth versus artificial teeth ………………………………………… 74 Table 3. Time of preparation for natural teeth and artificial teeth ……………………. 75 Table 4. Number of pecking movements for natural teeth and artificial teeth ………… 75 Table 5. Micro-CT analysis before preparation of natural tooth and 3D printed teeth ………………………………………………………………………………………… 76 Table 6. Micro-CT analysis before and after preparation with ProTaper Gold® (Denstply- Sirona) of natural tooth and 3D printed teeth ………………………………….……… 78 Table7. Time of preparation and number of pecking movements for natural tooth and 3D printed teeth …………………………………………………………………………… 79 Table 8. Micro-CT analysis before and after preparation with ProTaper Gold® (Dentsply- Sirona) and Endogal® (Endogal, Galician endodontics Company) of 3D printed Teeth ………………………………………………………..……………………………….. 81 Table 9. Time of preparation and number of pecking movements with ProTaper Gold® (Dentsply-Sirona) of 3D printed teeth ………………………………………………… 82 Table 10. Time of preparation and number of pecking movements with Endogal® (Endogal, Galician Endodontics Company) of 3D printed teeth ……………………… 82
11. APPENDICES
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 118 11. APPENDICES APPENDIX 1 - APPROVAL BY THE ETHICS COMMITTEE OF INSTITUTO ASTURIANO DE ODONTOLOGIA OF OVIEDO UNIVERSITY (IAO-23-0104)
APPENDICES 119 APPENDIX 2 - APPROVAL BY THE ETHICS COMMITTEE OF FERNANDO PESSOA UNIVERSITY (FCS/PI 429/23)
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 120
APPENDICES 127
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 128
APPENDICES 129
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 130
APPENDICES 131
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 132
APPENDICES 133
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 134
APPENDICES 135 PUBLICATION DERIVED FROM THIS THESIS APPENDIX 4 – PERMISSION TO REPRODUCE PAPER Title: Root Canal Preparation of a Commercial Artificial Tooth versus Natural Tooth - A MicroCT Study Authors: Tiago Reis1,2,*, Cláudia Barbosa2, Margarida Franco3, Catarina Batista3, Nuno Alves3, Pablo Castelo-Baz1, José Martin-Cruces1 and Benjamín Martin-Biedma1 Affiliation: 1 Department of Surgery and Medical-Surgical Specialties, School of Medicine and Dentistry, University of Santiago de Compostela, 15701 Santiago de Compostela, Spain 2 FP-I3ID, Faculty of Health Sciences, University Fernando Pessoa, 4249-004 Porto, Portugal 3 CDRSP, Polytechnic Institute of Leiria, Marinha Grande, 2430-028Marinha Grande, Portugal * Correspondence Journal: Applied Sciences Impact Factor 2022: 2.7 JCR Category 2022: Q2 CiteScore 2022: 4.5 SJR 2023: 0.51 E-ISSN: 2076-3417 Editorial: Multidisciplinary Digital Publishing Institute (MDPI) Publication Date: 18 of August of 2023 DOI: https://doi.org/10.3390/app13169400 Tiago Filipe dos Santos Sousa Reis Faria Contribution: Conceptualization and writing— review and editing Permission of MDPI: MDPI Open Access Information and Policy All articles published by MDPI are made immediately available worldwide under an open access license. This means everyone has free and unlimited access to the full-text of all articles published in MDPI journals; everyone is free to re-use the published material if proper accreditation/citation of the original publication is given; open access publication is supported by the authors' institutes or research funding agencies by payment of a comparatively low Article Processing Charge (APC) for accepted articles. No special permission is required to reuse all, or part of article published by MDPI, including figures and tables. For articles published under an open access Creative Common CC BY license, any part of the article may be reused without permission provided that the original article is clearly cited. Reuse of an article does not imply endorsement by the authors or MDPI. (https://www.mdpi.com/about/openaccess)
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 136
APPENDICES 143
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 144
APPENDICES 145
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 146
APPENDICES 147 PUBLICATION DERIVED FROM THIS THESIS APPENDIX 5 – PERMISSION TO REPRODUCE PAPER Title: Three Dimensional Printed Teeth in Endodontics: a new protocol for Micro-computed tomography studies Authors: Tiago Reis1,2,3 *, Cláudia Barbosa3,4, Margarida Franco2, Ruben Silva2, Nuno Alves2, Pablo Castelo-Baz5, José Martin-Cruces1 and Benjamin Martin-Biedma5 Affiliation: 1 Endodontics and Restorative Dentistry Unit, School of Medicine and Dentistry, University of Santiago de Compostela, 15701 Santiago de Compostela, Spain 2 Centre for Rapid and Sustainable Product Development, CDRSP, Polytechnic University of Leiria, Leiria Portugal 3 FP-I3ID, FP-BHS, Health Sciences Faculty, University Fernando Pessoa, Porto, Portugal 4 RISE-Health, University Fernando Pessoa, Porto; Portugal 5 Oral Sciences Research Group, Endodontics and Restorative Dentistry Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela, Spain * Correspondence Journal: Materials Impact Factor 2022: 3.4 JCR Category 2022: Q2 CiteScore 2022: 5.2 SJR 2023: 0.57 E-ISSN: 1996-1944 Editorial: Multidisciplinary Digital Publishing Institute (MDPI) Publication Date: 19 of April of 2024 DOI: https://doi.org/10.3390/ma17081899 Tiago Filipe dos Santos Sousa Reis Faria Contribution: Conceptualization, methodology, software, validation, resources, data curation, writing-original draft preparation and writing— review and editing Permission of MDPI: MDPI Open Access Information and Policy All articles published by MDPI are made immediately available worldwide under an open access license. This means everyone has free and unlimited access to the full-text of all articles published in MDPI journals; everyone is free to re-use the published material if proper accreditation/citation of the original publication is given; open access publication is supported by the authors' institutes or research funding agencies by payment of a comparatively low Article Processing Charge (APC) for accepted articles. No special permission is required to reuse all, or part of article published by MDPI, including figures and tables. For articles published under an open access Creative Common CC BY license, any part of the article may be reused without permission provided that the original article is clearly cited. Reuse of an article does not imply endorsement by the authors or MDPI. (https://www.mdpi.com/about/openaccess)
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 148
APPENDICES 149
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 150
APPENDICES 151
TIAGO FILIPE DOS SANTOS SOUSA REIS FARIA 152