Accuracy study of the Oculus Touch v2 versus inertial sensor for a single-axis rotation simulating the elbow’s range of motion
Abstract
This research was funded by the SPANISH GOVERNMENT (FEDER/Ministry of Science and Innovation/AEI.), Grant Number RTI2018-097122-A-I00.
Full text
Vol.:(0123456789) 1 3 Virtual Reality (2022) 26:1651–1662 https://doi.org/10.1007/s10055-022-00660-4 ORIGINAL ARTICLE Accuracy study oftheOculus Touch v2 versusinertial sensor forasingle‑axis rotation simulating theelbow’s range ofmotion AnaRojo1,2 · JavierCortina1· CristinaSánchez1· EloyUrendes1· RodrigoGarcía‑Carmona1· RafaelRaya1 Received: 22 November 2021 / Accepted: 1 May 2022 / Published online: 28 May 2022 © The Author(s) 2022 Abstract Virtual reality (VR) has emerged as a valid addition to conventional therapy in rehabilitation and sports medicine. This has enabled the development of novel and affordable rehabilitation strategies. However, before VR devices can be used in these situations, they must accurately capture the range of motion of the body-segment where they are mounted. This study aims to state the accuracy of the Oculus Touch v2 controller when used to measure the elbow’s motion in the sagittal plane. The controller is benchmarked against an inertial sensor (ENLAZA TM ), which has already been validated as a reliable measurement device. We have developed a virtual environment that matches both the Oculus Touch v2 and the inertial sensor orientations using a digital goniometer. We have also collected the orientation measurements given by each system for a set of 17 static angles that cover the full range of normal elbow flexion and hyperextension motion, in 10° intervals from −10° (hyperextension) to 150° (flexion). We have applied the intra-rater reliability test to assess the level of agreement between the measurements of these devices, obtaining a value of 0.999, with a 95% confidence interval ranged from 0.996 to 1.000. By analyzing the angle measurement outcomes, we have found that the accuracy degrades at flexion values between 70° and 110°, peaking at 90°. The accuracy of Oculus Touch v2 when used to capture the elbow’s flexion motion is good enough for the development of VR rehabilitation applications based on it. However, the flaws in the accuracy that have been revealed in this experimental study must be considered when designing such applications. Keywords Accuracy· Elbow· Inertial measurement unit· Range of motion· Rehabilitation· Virtual reality 1 Introduction Recent technological developments can be applied to sports medicine and rehabilitation, helping with both patient assessment and the execution of rehabilitation programs. Wearable sensors are especially popular because they can be used by a wide range of people, from patients with mobility problems to athletes who are recovering from an injury. One of their more important features is the ability to take range of motion (ROM) measurements of body-joints as accurately as goniometers, which are currently the most popular instrument in rehabilitation clinics (Costa etal. 2020). These quantitative measurements of human movement can be used to assess the presence of a motor disorder. In addition, wearable devices can be employed in a free-living environment, expanding their use cases in rehabilitation (Porciuncula etal. 2018). Finally, they also provide an opportunity for the collection of large amounts of data from many patients, which allows the growth of personalized and precision medicine (Dhawan 2016). Many wearable sensors use inertial Javier Cortina, Cristina Sánchez, Eloy Urendes, Rodrigo GarcíaCarmona, and Rafael Raya contributed equally to this work. * Ana Rojo [email protected] Javier Cortina javier.cor[email protected] Cristina Sánchez [email protected] Eloy Urendes elo[email protected] Rodrigo García-Carmona rodrigo.garciacar[email protected] Rafael Raya rafael.ra[email protected] 1 Departamento de TecnologÍas de la Información, Escuela Politécnica Superior, Universidad San Pablo-CEU, CEU Universities, Madrid28668, Spain 2 Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council, Madrid28002, Spain
1652 Virtual Reality (2022) 26:1651–1662 1 3 measurement units (IMUs), which contain a gyroscope, an accelerometer and a magnetometer. IMUs are small enough for the devices that employ to provide systematic, objective and reliable monitoring of human movement without hindering it or imposing space limitations (Camomilla etal. 2018). Another emerging technology that can be used for rehabilitation purposes is immersive virtual reality (VR), usually through headsets that can be combined with other devices, such as omni-directional treadmills, special gloves (Jerald 2019) or controllers. VR’s ability to generate realistic images, sounds and other sensations, and, through them, replicate a real environment or create an imaginary world, has proven to be very useful in this field. VR is currently gaining traction in many areas, such as teaching or health, and it is expected to grow even more in the near future (Checa and Bustillo 2020). Concerning rehabilitation, VR has emerged as a valid addition to conventional therapy, enriching new and low-cost rehabilitation strategies (Laver etal. 2017). VR can provide a positive learning experience, while being motivating and engaging (Maillot etal. 2012). This is especially important in rehabilitation, which can be a tough, prolonged and exhausting experience that patients might feel reluctant to proceed with. Any tool that is able to alleviate this problem is, therefore, particularly useful. Another advantage of VR-based therapy is the possibility of adapting the tasks to each particular patient’s needs. Virtual environments can be easily customized, so tasks tailored to the patient’s cognitive and physical impairments can be designed, maximizing brain reorganization and reactivating the areas of the brain involved in motor planning, learning and execution (Kim etal. 2005; Boyd and Winstein 2001), while maintaining engagement (Maillot etal. 2012). These modifications would be considerably more difficult and expensive to achieve with real environments. There are few published studies that use immersive VR for rehabilitation therapies, with most of which are nonimmersive experiences in which the patient can see their own body on a standard computer screen (Costa etal. 2020; Cui etal. 2019; Shum etal. 2019; Jost etal. 2021; Postolache etal. 2019; Oña etal. 2018; Borresen etal. 2019; Lee 2017). However, there are some that could be considered immersive VR, such as CAREN (Computer Assisted Rehabilitation Environment), which is a CAVE-like (Cruz-Neira etal. 1992) solution designed for balance assessment and therapy, gait analysis, adaptability, and motor control, among others (CAREN 2021). This integrates an instrumented dual-belt treadmill with a six DOF (Degrees of freedom) motion base and a 3D motion capture system inside an immersive environment. Some studies (De Luca etal. 2020; Rachitskaya etal. 2020; Calabrò etal. 2020; Kalron etal. 2016) have pointed out that this device may be a useful tool in rehabilitation therapies, which encourages the idea that VR could be a useful addition to the therapist’s toolset. 1.1 Use ofIMUs inimmersive applications Several studies have successfully employed IMUs with immersive applications to measure shoulder joint (Cui etal. 2019) or upper arm and forearm mobility (Kim etal. 2013). These approaches have shown their potential to reduce the human resources and time required to assess the patient’s joint mobility in comparison with traditional methods. In addition, these solutions could lead to the development of personalized training methods for upper extremity rehabilitation. There are similar systems that integrate more inertial sensors for motion capture of all body segments (Brandão etal. 2020; Fitzgerald etal. 2007). These solutions allow the patient to receive realtime visual stimuli from a virtual environment, and they provide the therapist with information about the movements performed during therapy. More complex developments (Patil etal. 2020) have proposed pose-tracking systems for virtual interaction by fusing multiple 3D light sensors and IMUs. However, inertial sensors are used to capture the orientation of each body segment, estimating the position and orientation of every joint of the body. This setup enables a real-time 3D avatar reconstruction. The accuracy of the results of this study shows that this solution is comparable to state-of-the-art pose-tracking systems. 1.2 Position andorientation trackers invirtual reality Motion tracking technologies can be combined with VR, which extends the innate tracking capabilities of this technology to body parts other than the head. This enables rehabilitation therapies to take advantage of some VR features (e.g., immersion, accurate head tracking), while collecting any additional physiological parameters that might be relevant. The more advanced VR Head-Mounted Displays (HMDs) that are currently available on the consumer market are supported by advanced six DOF tracking and are usually based on embedded infrared systems, as is the case with Oculus Rift TM (Farahani etal. 2016) or the Lighthouse Stations (Dempsey 2016) and is typically used with HTC Vive TM and other SteamVR-based headsets. These systems provide a very precise tracking of both position and orientation (Niehorster etal. 2017). The HTC Vive TM tracking system and the WorldViz TM Precision Position Tracking System have been compared (Niehorster etal. 2017) in terms of accuracy and latency, concluding that the RMS in orientation was less than 0.0113° for the former and less than 0.0053° for the latter for all the rotations. An accuracy analysis of the position and orientation
1653Virtual Reality (2022) 26:1651–1662 1 3 of the HTC Vive TM controllers and trackers (Spitzley and Karduna 2019) has concluded that the mean angular errors for both devices were less than 0.4°. In the same domain of tracking technologies for VR is the Antilatency TM system, which is a positional tracker designed to be used with a VR headset. This uses several trackers consisting of IMU sensors with real-time position correction based on optical data that allows for full-body tracking (LLC 2021). However, despite its potentially high performance, no scientific studies have been found that use this system in the field of motion tracking for rehabilitation. Despite the positive outcomes in position and orientation tracking of these systems, they still have to deal with two main problems: first, the reduced tracking areas limit the person’s movement space and activities; and second, the loss of tracking or changes in height measurements along the tracking space can cause incorrect measurements of the orientation of the device (Niehorster etal. 2017). There are several alternatives to this setup. For example, inside-out tracking uses infrared cameras that are mounted on the headset itself to scan the environment, but they are less accurate and are highly dependent on the environmental conditions (Passos and Jung 2020). Although most motion capture accuracy studies using trackers are not performed with inside-out tracking HMDs (Farahani etal. 2016; Dempsey 2016; Niehorster etal. 2017; Spitzley and Karduna 2019), two studies have focused on the positional and rotational accuracy of the Oculus Touch v1 controller. One of these studies (Jost etal. 2021) acquired static data samples from the device at different step sizes and at different points on a 2.4 ×2.4 m play-place. The authors determined that the maximum positional accuracy error of the Oculus Touch was 3.5 ±2.5 mm at the largest step size of 500mm along the z-axis. The other study (Shum etal. 2019) evaluated the rotations in three orthogonal axes for rotation intervals of 90°. The authors found that the rotational accuracy of the system was 0.34◦±0.38◦ for the HMD and 1.13◦±1.23◦ for the controller. However, no study has examined the orientation accuracy for movements in the sagittal plane. In addition, thorough studies of the accuracy of every component of a VR system that tracks a part of the user’s body or an object that the user interacts with are (as have been stated in this section) still lacking. This is an important gap in our understanding of the development of VR-based rehabilitation solutions. 1.3 Aim The main objective of this work is to validate the accuracy of the Oculus Touch v2 device (Oculus Quest 2 controller) to measure the elbow’s motion in the sagittal plane. To achieve this, we used a wireless motion capture wearable device as benchmark. This is based on an inertial measurement unit (IMU) sensor—the ENLAZA TM device—which is already validated as a reliable measuring device for the elbow’s range of motion (ROM) (Costa etal. 2020). The previous validity and feasibility study of the use of an inertial sensor to measure elbow and wrist active ROM were a comparative test-retest study between this device and a standard goniometry system with 29 participants. The results revealed that the ROM measurements that were obtained for the elbow had similar values for both systems. The inertial sensor had better reliability when compared to the goniometer for elbow measurements. The intra-rater and inter-rater reliability ICC values ranged from 0.83 to 0.96 and from 0.94 to 0.97, respectively. However, to be able to do this research, we must first fulfill the secondary objective of this work: to test the capability of an IMU sensor as a VR tracker in conjunction with a VR headset. This will enable us to confidently use the aforementioned IMU sensor as a proper benchmark for the Oculus Touch v2. In immersive applications, VR trackers should fulfill strict accuracy and latency requirements to induce the user’s perception of ownership over a virtual body (Banakou etal. 2013). Concerning latency, the existing literature has pointed out that a high delay between the time that a physical movement is performed and an output image is rendered on the HMD can decrease the user’s sense of immersion (Farahani etal. 2016). In fact, in VR, an end-to-end latency higher than 30 ms will break the sense of agency and body ownership (Raaen and Kjellmo 2015). Consequently, we must ensure that the IMU sensor respects this limit. To achieve both aims, we have developed a VR scenario for the Oculus Quest TM 2 that uses both an Oculus Touch v2 and the IMU sensor to track the elbow flexion–extension movement. 2 Methods 2.1 Approach We have devised the present setup with the aim of establishing a benchmark to test the orientation accuracy of Oculus Touch v2 controllers for VR applications, focusing on its application to the elbow’s ROM. This setup has also been designed to integrate the IMU sensor’s measurements, which will enable accuracy measurements of both devices (Oculus Touch v2 and IMU sensor) to be taken and compared. The wireless motion capture system is composed of three fundamental elements: the inertial sensor, a Raspberry Pi based-computer and an Oculus Quest 2 device. We have implemented the communication between the three blocks, which has resulted in a low latency and accurate position tracking method.
1654 Virtual Reality (2022) 26:1651–1662 1 3 2.2 Materials 2.2.1 Inertial sensors This approach uses an inertial sensor to capture the flexion–extension movement of the forearm. This device contains an IMU module that integrates a three-axis accelerometer, a three-axis gyroscope and a three-axis compass. The IMU sensor also includes a microcontroller unit (MCU) (8-bit AVR, 8 MHz, 32 KBytes of flash memory) that is in charge of acquiring the IMU data; computing the Direction Cosine Matrix (DCM) using the 3D accelerometer, gyroscope and magnetometer data following a published (Premerlani and Bizard 2009) algorithm; and interfacing with a computer unit via Bluetooth. 2.2.2 Computer unit The computer unit is a Raspberry Pi TM , which is a lowcost and small ARM-based computer that supports WiFi and Bluetooth wireless communications. This computing core handles the reception of data from the IMU sensor via Bluetooth, the calculation of Euler Angles orientation from such data, and the sending of these angles via WiFi to a VR device using UPD (User Datagram Protocol), which is chosen to reduce latency. 2.2.3 Virtual reality device The Oculus Quest TM 2 VR device is used. This is a VR HMD with six DOF for both the headset itself and two Oculus Touch v2 controllers. The Oculus Touch v2 is a handheld unit that contains a set of infrared LEDs. This allows the handheld unit to be tracked by the cameras that are present in the Oculus Quest TM 2 headset (Constine 2015) and an IMU sensor and determines their own orientation. 2.3 System design The DCM information from the IMU sensor is transmitted via Bluetooth to the Raspberry Pi, which transform the DCM into the angle data that will be used in the VR application that runs in the Oculus Quest 2. Once transformed, the angle data are transmitted via Wi-Fi using UDP to the VR headset. The application uses this data to move a virtual arm that replicates the user’s real arm in VR (see Fig.1). This Fig. 1 Diagram of the setup of both orientation tracking systems
1655Virtual Reality (2022) 26:1651–1662 1 3 movement will also be registered by the Oculus Touch v2. A digital goniometer will be used for the static orientation of the devices. Bluetooth communication between the sensor and the Raspberry Pi is established using the Serial Port Profile (SPP). This enables the angular orientation data to be sent in a binary format. The WiFi communication between the Raspberry Pi and the Oculus Quest TM 2 is implemented using the UDP protocol with a static IP-port endpoint to which data will be sent. We used UDP communication to prioritize low-latency over reliability because the system is tolerant to the loss of some datagrams (Rind etal. 2006). 2.4 Data processing From the first DCM received, we calculate a calibration matrix to have a new reference frame, which will correspond to the user’s initial position. From this neutral position, we can calculate a calibration matrix. Once the calibration matrix is known, we will be able to calculate the transformation matrix for each subsequent DCM received. Next, we can obtain the rotation angle of the reference system, which is equivalent to the rotation measured by the sensor. This process uses the following calculations: Rcal denotes the calibration matrix, Rs denotes the data sent by the IMU (in relation to the reference frame), and Rt denotes the transformation matrix. We calculate the movement in relation to the calibration using the following equation: where Ra denotes the initial matrix, representing the initial position and orientation; T denotes the transformation matrix, representing the transformation applied to the initial matrix (a rotation in this case); and Rb denotes the final matrix after the transformation, representing the position and orientation after the transformation. This corresponds in our case to: Rs=Rt×Rcal , so we have that: After calculating Rt , we normalize it to ensure that the system is orthonormal. Finally, we convert Rt to Euler angles, using the formulas of the ZXY convention, as proposed by the International Society of Biomechanics (ISB) (Wu etal. 2005). The sequence ZXY can be intuitively interpreted as the individual Euler rotations. This means that the first Euler angle represents a flexion of the arm, the second represents an abduction of the arm, and the third represents an internal/external rotation of the arm (Campeau-Lecours etal. 2020). These data are sent via UDP to replicate the movement virtually. (1) Rb=T×Ra (2) R t=Rs×R −1 cal 2.5 Latency analysis To measure the total delay of the developed wireless motion capture system, we implemented a time measurement tool in all processes of the data transmission thread. The latency of the system represents the total delay between the instant that the movement occurs to the time that it is displayed on the Oculus Quest TM 2 HMD. Applying the following approach, we expected to find that the end-to-end latency of this setup stays below 30ms (Raaen and Kjellmo 2015) to avoid breaking the sense of body ownership in VR experiences. The simplest way to record these time delays is to write the data packet with a standardized time stamp between events. In this way, when this information is received by the HMD, data time can be stored for later analysis. To support the latency analysis, we store both latency data, as follows: the Raspberry Pi data processing timestamp for each sample and the elapsed-time of the communication process (UDP protocol), which is the time to read an incoming message for 1min. From these results, the time averages and the standard deviation between the maximum and minimum values are calculated. Because the inertial sensor has a fixed sampling rate of 50Hz, this means that we have a data acquisition rate of 20ms. The times at which each piece of data is received are then captured to know this delay with respect to the sampling rate because a communication rate from IMU to VR HMD of 20ms would be the expected value in a system with no-latency. This delay reflects the time cost of the three processes: the Bluetooth data transmission between the IMU sensor and the Raspberry Pi, the computation of the Euler angles done by the Raspberry Pi and the UDP socket communication process. Table1 shows the time costs of end-to-end communication, the IMU sampling rate and the difference between them. This results in the end-to-end latency. As can be seen, the latency stays inside the values recommended by the literature. 2.6 Data analysis To analyze the accuracy of the Oculus Touch v2 controller as a tracker and an elbow ROM measurement device, we compare it with the IMU sensor using a digital goniometer Table 1 Outcomes of the communication rate from the IMU sensor to the VR HMD (ms), IMU sensor sampling rate (ms) and end-to-end communication latency (ms) Communication rate (ms) IMU sampling rate (ms) Latency (ms) Mean±SD Mean±SD Mean±SD 23.709 ±18.73 20.26 ±0.48 3.709 ±18.73
1656 Virtual Reality (2022) 26:1651–1662 1 3 to set the devices in different orientations. The ENLAZA TM , the particular IMU sensor that we used has already been validated for elbow ROM (Costa etal. 2020), will be used the baseline against which the Oculus Touch v2 controller is compared. Accuracy assessment has been established by comparing the means and standard deviations of the pairs of measurements. To measure the reliability of this validation procedure, we calculated the ICC (95% confidence interval [CI]) using the analysis of reliability of the IBM SPSS Statistics 27 software suite. In this study, the ICC reflects the variation in the measurements made by the devices in the same setup under the same conditions. We took the design of Koo and Li (2016) as a reference and applied the model of two-way mixed effect and absolute agreement definition. We did this because this is an inter-rater reliability study for two different devices and it is expected to observe agreement between their averaged measurements. 2.7 Protocol We assessed the accuracy of the orientation measures reported by the Oculus Touch v2 at each orientation. Specifically, for accuracy, we looked at whether the roll orientation of the Oculus was stable across space. The orientation of the controllers is referenced with respect to their local coordinate system and not with respect to the external HMD coordinate system. The Oculus Touch v2 bases its measurements on a reference plane that is aligned with its button pad. Therefore, for initial orientation (0, 0, 0), the aim axis is tilted 40° with respect to the horizontal plane of the grip (see Figs.2 and 3). To compare static orientation measurements between the Oculus Touch v2 controller and the IMU sensor, both devices were attached to the movable segment of the digital goniometer Silverline TM . The Oculus Quest 2 headset was located on a stable table near the goniometer to record the measurement data. The system’s setup protocol was run before each data collection session. The 3D environment built in Unity has two 3D representations of the goniometer (the first for the IMU sensor and the second for the Oculus Touch v2), consisting of two segments and two joints. The first joint enables the rotation of the whole object, and the other joint enables the rotation of the last segment around the X-axis, replicating the real goniometer’s rotation (see Fig.4). When the IMU sensor and the Oculus Touch v2 rotate, their angles of rotation are replicated in the corresponding Unity object’s joints, to translate the real movement to the VR environment. This allows the data from both devices to be simultaneously stored and represented in the virtual environment. The angles measured by the IMU sensor and the controller are taken for each set angle that is assessed with the goniometer. This allows us to later evaluate the accuracy of both devices in characterizing this range of angular values. According to the existing literature on the elbow joint normal ROM values (Soucie etal. 2011), healthy men and women aged 9–69 years can achieve a flexion value ranged Fig. 2 A Representation of the local coordinate system of an Oculus Touch v2. B Schematic representation of the setup with an Oculus Touch v2 attached to the digital goniometer in its neutral orientation Fig. 3 A controller holder was 3D printed, which allowed the controller to be reliably rotated by 90°. The controller could then perform three orthogonal rotations about a single axis. Both Oculus Touch v2 and the inertial sensor were attached to the digital goniometer
1657Virtual Reality (2022) 26:1651–1662 1 3 between 143.5° and 150.0° and a hyperextension value ranged between −0.8◦ and −6.4◦ (see Fig.5). Based on these data, we captured the expected normal ROM angles: from 350° (equivalent to −10◦ in hyperextension) to 150°, in 10° intervals, which are shown in the results section (Table2). 3 Results Table3 shows the results for the angle measurements performed with the IMU sensor and the Oculus Touch v2, respectively, with both devices fixed to the goniometer. To better characterize the measured angle, the average value of three repetitions for each angle was used instead. The difference between the mean value of each device and the reference value (goniometer) is shown. This shows the precision achieved by each system. By observing the descriptive results of the measurements, it can be assumed that the average value replicates the reference value because of the narrow dispersion of the samples (standard deviation) for each angle. The standard deviation outcomes of the IMU sensor ranged from 0.127° to 3.307°, and the Oculus Touch v2 standard deviation outcomes ranged from 0.342° to 1.472°. The standard error of the mean (SEM) was calculated to measure the dispersion of sample means around the population mean. The average standard error of the IMU sensor outcomes is 0.307°, with a minimum value of 0.076° and a maximum value of 1.909°. Meanwhile, the average standard error of the Oculus Touch v2 outcomes is 0.449°, with a minimum value of 0.197° and a maximum value of 0.849°. The degree of agreement between the measurements of the devices was statistically estimated by applying the inter-rater reliability test. We obtained an ICC of 0.999, with values ranging from 0.996 to 1.000 for a 95% confidence interval. To better illustrate the low dispersion of the results, the mean values and their corresponding standard deviations for each device are graphed in Figs.6 and 7. The data for 350° have been excluded to preserve the scale of the graph (Fig.6), but their values are similar to those depicted. 4 Discussion The present study aimed to compare the static rotation measurements between an Oculus Touch v2 controller and the IMU sensor. These measurements were meant to state the former’s accuracy in measuring orientation for the sagittal plane roll rotation, with the aim of tracking kinematic data for an immersive VR application. Fig. 4 Virtual goniometers in the Unity 3D engine. The left-hand image represents the angles measured by the Oculus Touch v2 controller, while the right-hand image represents the angles recorded by the IMU sensor Fig. 5 Representation of the normal range of motion of elbow joint
1658 Virtual Reality (2022) 26:1651–1662 1 3 An ICC value of 0.999 was obtained for the reliability measurement (Table4), with a 95% CI that ranged from 0.996 to 1.000, indicating good reliability according to the existing literature (Koo and Li 2016). In addition, the F-test (with truth value equals 0) value that we obtained is 872.322 with a statistical significance of p≤0.001 . Basing on the ICC results, we proceed to discuss the results of each device in more detail for each angle range. For the IMU sensor outcomes, the standard deviation results for each measured angle show low dispersion. However, for the Oculus Touch v2 outcomes, higher standard deviation values are observed in most cases. The angles reported by the Oculus Touch v2 between the static angles of 70° and 110° deviate considerably from the goniometer reference values, as shown in the mean difference between goniometer and Oculus Touch v2 values in Table2. The average SEM value of the IMU sensor was 0.307°. In contrast, the Oculus Touch v2 showed an average SEM value of 0.449° and a mean difference of 2.22°. The latter result is similar to the mean difference angle value of 1.13 ±1.23 that was reported by Jost etal. (2021) in their quantitative analysis of the position and orientation of the Oculus Rift TM controllers, which correspond to the first version of the Oculus Touch. These authors already reflected the consistent error in accuracy of the Oculus Touch (v1) for roll rotation in the z-axis. According to Ertzgaard etal. (2016) and Youdas etal. (1991), comparing different (inertial and optical) ROM assessment systems, small systematic errors were detected in all planes of elbow motion, ranging from 1.2° to 1.3°. Meanwhile, Brodie etal. (2008) investigated the accuracy of IMUs from XSens Technologies (set as a gold-standard) and obtained a RMS error of between 0.8 and 1.3. Then, assuming that all sensing systems can have an average systematic measurement error around 1.3° (Costa etal. 2020; Youdas etal. 1991; Brodie etal. 2008), values that are below or close to this threshold over the entire range Table 2 Results for angle measurements and SEM of 350° to 150° from the IMU sensor Reference IMU Ref.-IMU difference SEM Mean±SD 350.00° +350.036°±0.747° +0.036° 0.431° 0.00° −0.190°±0.537° −0.190° 0.310° 10.00° +9.553°±0.263° −0.446° 0.152° 20.00° +19.980°±0.127° −0.020° 0.073° 30.00° +30.143°±0.200° +0.143° 0.116° 40.00° +40.470°±0.243° +0.470° 0.254° 50.00° +50.293°±0.331° +0.293° 0.191° 60.00° +60.016°±0.132° +0.016° 0.076° 70.00° +70.167°±0.348° +0.166° 0.201° 80.00° +80.953°±0.675° +0.953° 0.390° 90.00° +90.246°±0.244° +0.246° 0.1412° 100.00° +99.996°±0.295° −0.003° 0.170° 110.00° +112.323°±3.307° +2.323° 1.909° 120.00° +120.930°±0.201° +0.930° 0.116° 130.00° +130.146°±0.331° +0.146° 0.191° 140.00° +139.876°±0.331° −0.123° 0.191° 150.00° +149.923°±0.526° −0.076° 0.304° Overall averages +0.286° +2.221° 0.307° Table 3 Results for angle measurements and SEM of 350° to 150° from the Oculus Touch v2 Reference Oculus Ref.-Oculus difference SEM Mean±SD 350.00° +350.036° +350.166°±0.694° 0.401° 0.00° −0.190° +0.566°±0.865° 0.499° 10.00° +9.553° +9.070°±0.766° 0.442° 20.00° +19.980° +19.273°±0.383° 0.221° 30.00° +30.143° +28.456°±0.436° 0.252° 40.00° +40.470° +38.473°±0.507° 0.293° 50.00° +50.293° +46.746°±1.179° 0.681° 60.00° +60.016° +55.893°±0.925° 0.534° 70.00° +70.167° +63.680°±0.956° 0.552° 80.00° +80.953° +69.716°±0.342° 0.197° 90.00° +90.246° +73.003°±0.521° 0.301° 100.00° +99.996° +107.943°±0.723° 0.418° 110.00° +112.323° +114.733°±0.957° 0.553° 120.00° +120.930° +121.823°±1.472° 0.850° 130.00° +130.146° +128.863°±0.932° 0.538° 140.00° +139.876° +137.366°±0.711° 0.410° 150.00° +149.923° +146.46°±0.868° 0.501° Overall averages +0.286° +2.221° 0.449°
1659Virtual Reality (2022) 26:1651–1662 1 3 Fig. 6 Comparison of the IMU sensor and the Oculus Touch v2 mean values and standard deviations from 0° to 70° Fig. 7 Comparison of the IMU sensor and the Oculus Touch v2 mean values and standard deviations from 80° to 150°