High-precision measurement of the mass difference between 102Pd and 102Ru
Full text
This is a self-archived version of an original article. This version may differ from the original in pagination and typographic details. Author(s): Title: Year: Version: Copyright: Rights: Rights url: Please cite the original version: CC BY-NC-ND 4.0 https://creativecommons.org/licenses/by-nc-nd/4.0/ High-precision measurement of the mass difference between 102Pd and 102Ru © 2018 Elsevier B.V. Accepted version (Final draft) Nesterenko, Dmitrii; Canete, Laetitia; Eronen, Tommi; Jokinen, Ari; Kankainen, Anu; Novikov, Yu.N.; Rinta-Antila, Sami; de Roubin, Antoine; Vilén, Markus Nesterenko, D., Canete, L., Eronen, T., Jokinen, A., Kankainen, A., Novikov, Yu.N., Rinta-Antila, S., de Roubin, A., & Vilén, M. (2019). High-precision measurement of the mass difference between 102Pd and 102Ru. International Journal of Mass Spectrometry, 435, 204-208. https://doi.org/10.1016/j.ijms.2018.10.038 2019
Accepted Manuscript Title: High-precision measurement of the mass difference between 102Pd and 102Ru Author: D.A. Nesterenko L. Canete T. Eronen A. Jokinen A. Kankainen Yu.N. Novikov S. Rinta-Antila A. de Roubin M. Vilen PII: S1387-3806(18)30325-7 DOI: https://doi.org/doi:10.1016/j.ijms.2018.10.038 Reference: MASPEC 16073 To appear in: International Journal of Mass Spectrometry Received date: 20 August 2018 Revised date: 22 October 2018 Accepted date: 29 October 2018 Please cite this article as: D.A. Nesterenko, L. Canete, T. Eronen, A. Jokinen, A. Kankainen, Yu.N. Novikov, S. Rinta-Antila, A. de Roubin, M. Vilen, High-precision measurement of the mass difference between 102Pd and 102Ru, <![CDATA[International Journal of Mass Spectrometry]]> (2018), https://doi.org/10.1016/j.ijms.2018.10.038 This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
Page 1 of 8 Accepted Manuscript High-precision measurement of the mass difference between 102Pd and 102Ru D.A. Nesterenkoa,b,∗ , L. Canetea, T. Eronena, A. Jokinena, A. Kankainena, Yu.N. Novikovb,c, S. Rinta-Antilaa, A. de Roubina, M. Vilena aUniversity of Jyv¨askyl¨a, P.O. Box 35, FI-40014 University of Jyv¨askyl¨a, Finland bPetersburg Nuclear Physics Institute, Gatchina 188300, Leningrad region, Russia cSt. Petersburg State University, 7/9 Universitetskaya nab., St. Petersburg 199034, Russia Abstract The Q-value for the neutrinoless double electron capture on 102Pd, Q(102Pd), is determined as the atomic mass difference between 102Pd and 102Ru. A precise measurement of the Q(102Pd) at the SHIPTRAP Penning trap showed a more than 10σdeviation to the adopted Atomic Mass Evaluation (AME) value. The reliability of the SHIPTRAP measurement was challenged because the AME value was based on numerous experiments including βand electron capture decays and very precise (n, γ) data, all agreeing with each other. To solve the discrepancy, the Q(102Pd) has now been determined with the JYFLTRAP Penning trap at the IGISOL facility in the Accelerator Laboratory of the University of Jyv¨askyl¨a. The measurement was performed both with the Time-of-Flight and the Phase-Imaging Ion Cyclotron Resonance techniques. The obtained result, Q(102Pd) = 1203.472(45) keV, is eight times more precise and agrees well with the value obtained at SHIPTRAP, Q(102Pd) = 1203.27(36) keV, confirming that 102Pd is not a good candidate for a search for neutrinoless double-electron capture. Keywords: Penning trap, High-precision mass spectrometry, Q-values, Neutrinoless double-electron capture 1. Introduction Penning Trap Mass Spectrometry (PTMS) offers versatile opportunities to study fundamental properties of matter via high-precision atomic mass measurements [1]. The method has several advantages:5 •Highest precision due to the use of frequency as a measure; •Sensitivity with the ability to measure the cyclotron frequency for an individual ion; •Reliability provided by the possibility to use carbon-10 cluster ions for a direct calibration. PTMS has been used for investigating fundamental properties in nature, such as Charge Parity Time (CPT) reversal symmetry [1], some problems of quantum chromodynamics (QCD) [2], quantum electrodynamics (QED)15 [3], and neutrino physics [4]. Values for some fundamental constants in physics can also be explored using PTMS [1]. These experiments require highest achievable precisions. Currently, the record precisions obtained with PTMS are around 10−11 [5]. Meanwhile, for many problems in nu-20 clear structure and astrophysics, a few keV precision in nuclear mass values (a relative uncertainty of ≈10−8) is ∗Corresponding author Email address: [email protected] (D.A. Nesterenko) quite sufficient. However, even with the lower requirements for the precision, the reliability and sensitivity of PTMS remain very important for these measurements.25 During the last decade PTMS has shown quite significant discrepancies in the mass differences of certain isobaric nuclides (see e.g. [6, 7, 8]) when compared to the atomic mass evaluations (AME) [9, 10, 11]. In [7], the double electron-capture mass difference Q between30 102Pd and 102Ru determined at the SHIPTRAP Penning trap, was found to deviate by more than 10 standard deviations from the value given in AME2003 [9]. The case was carefully examined in the next atomic mass evaluation AME2012 [10]. It was found that all data from the flow of35 information matrix containing various spectroscopic connections are self-consistent and can hardly be erroneous (see Fig. 1). Thus, the reliability of the PTMS result [7] was seriously questioned. In AME2016 [11], the claim was mitigated by referring to an unpublished less accurate40 work from the GSI storage ring. However, many arguments given in [10] to support the indirect methods, and thus against the PTMS result, are still valid. In this work, we have performed a PTMS measurement for the 102Pd −102Ru mass difference using the45 JYFLTRAP Penning trap mass spectrometer. As it is independent of the previous PTMS measurement at SHIPTRAP [7], it provides a way to test the reliability of the method and solve the discrepancy to the other values in the atomic mass evaluations.50 Preprint submitted to International Journal of Mass Spectrometry October 19, 2018
Page 2 of 8 Accepted Manuscript 2. Discrepancies in the values for the 102Pd − 102Ru mass difference The mass difference of 102Pd −102Ru has been previously measured with the SHIPTRAP Penning trap during a campaign searching for a resonant enhancement of55 neutrinoless double-electron capture. The decay energy (i.e. the mass difference) Q(102Pd) = 1203.27(36) keV was determined using the Time-of-Flight Ion Cyclotron Resonance technique [7]. The measured value was 30 keV higher than evaluated in the Atomic Mass Evaluation 200360 (AME2003) [9], Q(102Pd) = 1173.0(24) keV. The observed difference of more than 10 standard deviations triggered a thorough analysis on the possible reasons for the discrepancy in AME2012 [10]. Around dozen Q-values were measured using the same procedure in the neutri-65 noless double-electron capture campaign at SHIPTRAP, and 102Pd −102Ru was one of the few cases deviating significantly from AME. Figure 1: Flow of information diagram [10] showing the connections between 102Pd and 102Ru. The type of relation and its precision (in keV) is given for each connection. The arrows indicate the contribution of the relation in %. The resulting mass precision is given in keV in the lower right corner of each box. The Q-value for 102Pd in AME2012 [10] is based on experimental data connecting 102Pd and 102Ru, see70 Fig. 1. All the measured beta-decay and electron-capture Q-values were collected, and the connections with highermass isotopes through precise (n, γ) measurements were taken into account as well. As shown in [10], the Q-values obtained with these different experimental links agree with75 each other. Actually all connections have been determined by more than two groups and sometimes with different methods which yield results in good agreement. Thus, it was concluded in [10] that there is no reason to suspect any individual spectroscopic measurement.80 From the PTMS side, the result for the mass difference 102Pd −102Ru is unlikely to be incorrect. It was measured at SHIPTRAP during the same experimental campaign as 106Cd −106Pd and 144Sm −144Nd whose PTMS results are in agreement with the AME values. This makes the85 case 102Pd −102Ru special and calls for a new independent PTMS measurement. 3. Experimental method and results In this work, the mass difference of 102Pd and 102Ru has been measured with the JYFLTRAP double Penning90 trap mass spectrometer [12] at the Ion Guide Isotope Separator On-Line (IGISOL) facility [13]. The 102Pd+and 102Ru+ions were produced using two different electric discharge ion sources at separate 30 kV high-voltage platforms (see Fig. 2). A natural palladium source was located95 upstairs in a dedicated offline ion source station whereas the ruthenium ions were produced with a source located inside the IGISOL target chamber. Ions from one ion source at a time were selected by switching voltages on an electrostatic deflector blocking either the vertical (offline100 station) or horizontal (IGISOL) beamline. A 55◦dipole magnet was used to select the 102Pd+(1.02 % isotopic abundance) and 102Ru+(31.55 % isotopic abundance) ions from the natural isotopic mixture based on their mass-to- charge ratio of A/q = 102. Then, 102Pd+or 102Ru+ions105 were injected into a gas-filled radio-frequency quadrupole [14], where they were cooled and bunched. The ion bunches were transported to the JYFLTRAP double Penning trap [12] placed inside a 7-T superconducting solenoid. The first preparation trap cooled, cen-110 tered and additionally purified the ion sample via a massselective buffer gas cooling technique [15]. This took around 270 ms for the 102Pd+and 102Ru+ions. The ions from the preparation trap were transferred into the second trap known as the measurement trap where115 ions’ cyclotron frequencies were measured. The traps were operated simultaneously. While the cyclotron frequency of the ions was being measured in the measurement trap, a new bunch of ions was being prepared in the preparation trap.120 The cyclotron frequency νcof an ion with mass mand charge qin a magnetic field with strength Bis given by νc=1 2π q mB. (1) The mass difference between 102Pd+or 102Ru+ions was determined from the measured cyclotron frequency ratio R: R=νc(102Ru+) νc(102Pd+)=m(102Pd+) m(102Ru+)(2) Two different methods were used to measure the cyclotron frequencies νcand determine the cyclotron frequency ratio R=νc(102Ru+)/νc(102Pd+). Firstly, a conventional Time-of-Flight Ion Cyclotron Resonance (ToF- ICR) technique [16, 17] with a 25-750-25 ms (On-Off-On)125 Ramsey-type excitation pattern [18, 19, 20] was employed (see Fig. 3). For comparison, the SHIPTRAP result of 2
Page 3 of 8 Accepted Manuscript Figure 2: The experimental area of the IGISOL facility, where 1 - the target chamber, 2 - the offline ion source station, 3 - the 55◦dipole magnet, 4 - the electrostatic beam switchyard, 5 - the gas-filled radio-frequency quadrupole, 6 - the JYFLTRAP Penning-trap setup. Q(102Pd)-value [7] was obtained with the ToF-ICR technique and Ramsey-excitation pattern 100-1800-100 ms (On- Off-On).130 In addition to the ToF-ICR method, we applied the Phase-Imaging Ion Cyclotron Resonance (PI-ICR) technique [21, 22] which has recently been implemented at JYFLTRAP [23]. Here, the cyclotron frequencies for 102Ru+ and 102Pd+were measured as a sum of two radial-motion135 frequencies: magnetron frequency ν−and modified cyclotron frequency ν+(the measurement scheme #2 in Ref. [22]). This method has been used in a number of experiments on high-precision Q-value measurements, for example in [3, 24, 25].140 The used PI-ICR measurement scheme is shown in Fig. 4. The basic principle of the measurement is to determine the “magnetron” and “cyclotron” phases of ion radial motion on the detector with the positions defined by the polar angles α−and α+, respectively, with respect to the trap center. The angle between the two phase images αc=α+−α−is related to the cyclotron frequency νcby the equation: νc=ν−+ν+= (αc+ 2πn)/2πt, (3) where nis the full number of revolutions, which the studied ions would perform in a pure magnetic field Bduring a phase accumulation time t. Two different phase accumulation times, 200 ms and 400 ms, were employed for the measurements.145 Two excitation patterns were applied to measure the accumulated phases of ion motion and to determine the cyclotron frequency νc(see Fig. 4). They differ only by a position of the quadrupolar rf pulse. First, the ions were transported from the preparation trap to the center of the150 measurement trap and the coherent components of ion’s magnetron and axial motions were reduced via dipolar rf pulses at the corresponding motion frequencies. Then, a dipolar 1-ms rf pulse at modified cyclotron frequency ν+ was applied to excite the cyclotron motion of ions to a155 certain radius. In pattern 1, the cyclotron motion of ions was first converted into the magnetron motion via a quadrupolar 2-ms rf pulse at the cyclotron frequency. Then the ions were let to undergo magnetron motion with the magnetron160 frequency ν−for a time t, and accumulate a magnetronmotion phase. After this, ions were extracted out from the measurement trap and their radial positions in the trap were projected onto a position-sensitive detector (a multichannelplate detector with a delay line anode). Thus,165 pattern 1 provided the image of the magnetron-motion phase of ions with the polar angle α−(see Fig. 5). 3
Page 4 of 8 Accepted Manuscript Figure 3: A typical time-of-flight resonance of 102Pd+with 25-750- 25 ms (On-Off-On) Ramsey excitation pattern. The black points with error bars represent the mean time-of-flight for each scanned frequency. The solid red line is a fit of the theoretical curve [20] to the data points. The blue shading around the data poins indicates the number of ions in each time-of-flight bin: the darker the blue, the more ions. The position of the central minimum was determined before the measurements using conventional ToF-ICR with a single 800-ms excitation pulse [17]. In pattern 2, the ions performed the cyclotron motion for a time t, accumulating a cyclotron-motion phase. Before extracting the ions out from the measurement trap,170 a quadrupolar 2-ms rf pulse at the cyclotron frequency was applied in order to convert the fast cyclotron motion to the slow magnetron motion. The positions of the extracted ions were projected onto a position-sensitive detector similarly to pattern 1. Pattern 2 provided the image175 of the cyclotron-motion phase of ions with the polar angle α+(see Fig. 5). Note that the complete conversion of the cyclotron motion to the magnetron motion preserves the modulus of the angle for the accumulated phase although flipping the sign of the angle [22, 26].180 The patterns 1 and 2 were applied alternately to obtain the images of magnetron and cyclotron phases (see Fig. 5). Thus, determination of the angles α−and α+ were performed quasi-simultaneously. The trap center on the detector was determined once per around 3.5 hours, i.e.185 before and after each measurement set. To reduce possible distortions in the ion-motion projections onto the detector, the positions of the magnetron and cyclotron phase images were chosen such that the angle αcdid not exceed a few degrees. To average the ion positions over all magnetron190 phases and eliminate the possible angular shift of the centroid position due to possible residual magnetron motion (after its coherent component had been reduced), the start time of the dipolar excitation pulse at the frequency ν+ was scanned over a magnetron period (≈600 µs). In ad-195 dition, the start time of the extraction pulse was scanned over a cyclotron period (≈0.95 µs) to average the ion positions over all cyclotron phases in order to eliminate possible residual cyclotron motion after the conversion. Note that the ion interactions with the residual gas molecules200 in the measurement trap decrease the radius of the fast cyclotron motion and smear the image of the cyclotron phase spot [22], increasing the statistical uncertainty but not causing a systematic shift. The cyclotron frequency measurements for 102Ru+and205 102Pd+were performed alternately for several days. For ToF-ICR, the ions were swapped after each frequency scan (≈1.3 min). For PI-ICR, two measurement rounds with tacc = 400 ms (around ≈47 s), or three rounds with tacc = 200 ms (≈41 s), were carried out before swapping between210 the 102Ru+and 102Pd+ions. The data for 102Ru+and 102Pd+were grouped in the data analysis by 10, 8 and 9 rounds for ToF-ICR, PI-ICR with tacc = 400 ms and PI-ICR with tacc = 200 ms measurements, respectively, to obtain enough statistics for fit-215 ting (600-900 ions). The cyclotron frequency of 102Ru+, measured before and after 102Pd+, was linearly interpolated to the measurement time of 102Pd+to determine a single frequency ratio. Altogether 15 around 3.5-hour measurement periods were performed. For each period, a220 weighted mean of the frequency ratio R3.5hwas calculated. The maximum of the internal and external errors has been chosen for the weighted mean frequency ratios R3.5h. The nonlinear drift of the magnetic field between two neighboring frequency measurements was negligible com-225 pared to the statistical errors. The mass-dependent uncertainties were neglected because 102Pd+-102Ru+is a mass doublet with the same A/q. Count-rate class analysis [27] was performed for the determined cyclotron frequency ratios to study ion-ion interactions. The data were divided230 into five groups according to the number of detected ions per bunch. No dependence of the frequency ratio on the number of detected ions were observed (see Fig. 6), and only data up to 5 ions/bunch were taken into account in the analysis. For the PI-ICR technique, the systematic er-235 rors due to non-simultaneous measurements of the center and the phase positions, and the distortion of the ionmotion projection onto the detector, were around 50-70% of the statistical errors. Figure 7 shows the frequency ratios R3.5hmeasured in240 this work. The first six measurements were performed with the ToF-ICR technique and the subsequent nine with the PI-ICR technique. The uncertainties of R3.5hare similar in both methods because the excitation time in the ToF-ICR technique was four times longer than the phase accumu-245 lation time in the PI-ICR technique, and additional systematic errors were added for the PI-ICR measurements. The calculated Birge ratio [28] was 0.98 supporting that all systematic uncertainties have been properly taken into account. The higher, internal uncertainty, was adopted250 for the final weighted mean of cyclotron ratios R3.5h,R= 1.00001267844(47). 4
Page 5 of 8 Accepted Manuscript Figure 4: Measurement pulse scheme for the cyclotron frequency determination νcin the PI-ICR technique. The magnetron and cyclotron phases are accumulated in the patterns 1 and 2, respectively. Figure 5: The trap center and accumulated phase spots for 102Pd+ ions on the position-sensitive ion detector for a single cyclotron frequency measurement (≈2 min) with the phase accumulation time tacc = 200 ms. The magnetron-motion phase was accumulated using pattern 1 and the cyclotron-motion phase with pattern 2 of the excitation-pulse scheme. The Q-value can be calculated from the cyclotron frequency ratio as Q =m(102Pd) −m(102Ru) = (m(102Ru) −me)(R−1), (4) where m(102Pd) and m(102Ru) are atomic masses of 102Pd and 102Ru, respectively, meis the electron mass and R is the cyclotron frequency ratio of singly charged ions of255 102Ru and 102Pd, respectively. The difference of binding energies of the valence electrons for 102Ru and 102Pd is less than 2.5 eV [29], and can be neglected. Thus, the final cyclotron frequency ratio Rresults in Q = 1203.472(45) keV. It is in a good agreement with260 the value obtained at SHIPTRAP [7], Q = 1203.27(36) keV, and is eight times more precise. Figure 6: The cyclotron frequency ratio as a function of the number of detected ions per bunch for one of the 3.5-hour measurement periods. The blue line marks a linear fit. The 1σconfidence band of the fit is shown in blue. The red line and the red-shaded band mark the mean of the ratio, averaged over one to five ions per bunch, and the 1σuncertainty, respectively. The slope of the linear fit is in agreement with the mean value within the confidence band for all measurement periods. 4. Conclusions The new precise direct measurement of the mass difference 102Pd −102Ru with the JYFLTRAP Penning trap265 mass spectrometer is in a good agreement with the previous Penning-trap measurement performed at SHIPTRAP. Therefore, it confirms that the SHIPTRAP PTMS result is correct and calls for a reanalysis of mass and spectroscopic data that lead to a more than 10σdeviation to the270 adopted mass evaluation value. It is worthwhile to note that in AME2016, two pieces of data, 102Rh(β−)102Pd and 103Pd(EC)103Rh, have already been discarded. Our result also confirms the conclusion from the SHIPTRAP measurement [7] that there is no resonant enhancement for275 search for neutrinoless double-electron capture in 102Pd. In conclusion, Penning-trap mass spectrometry is a reliable and precise method to determine atomic masses for 5
Page 6 of 8 Accepted Manuscript Figure 7: The measured cyclotron frequency ratios νc(102Ru+)/νc(102Pd+) (the axis on the left) and Q values (the axis on the right) determined in this work. Each point represents one around 3.5-hour measurement. The red-shaded band shows the total uncertainty of the weighted mean. fundamental physics problems, neutrino physics, nuclear physics as well as for astrophysics.280 Acknowledgements This work has been supported by the Academy of Finland by the project ”State-of-the-art ion beam developments for JYFL-ACCLAB”, decision No. 273526. A.K. acknowledges the support from the Academy of Finland285 under grant No. 275389 and D.N. and L.C. under grants No. 284516 and 312544. T.E. acknowledges the support from the Academy of Finland under grant No. 295207 and A.R. under grant No. 306980. References290 [1] K. Blaum, Y. N. Novikov, G. Werth, Penning traps as a versatile tool for precise experiments in fundamental physics, Contemporary Physics 51 (2) (2010) 149–175. doi:10.1080/ 00107510903387652. [2] T. Eronen, J. C. Hardy, High-precision Qec-value measurements295 for superallowed decays, Eur. Phys. J. A 48 (4) (2012) 48. [3] F. K¨ohler, et al., Isotope dependence of the Zeeman effect in lithium-like calcium, Nature Communications 7 (2016) 10246. doi:10.1038/ncomms10246. [4] S. Eliseev, T. Eronen, Y. N. Novikov, Penning-trap mass spec-300 trometry for neutrino physics, International Journal of Mass Spectrometry 349-350 (2013) 102 – 106, 100 years of Mass Spectrometry. doi:doi.org/10.1016/j.ijms.2013.03.010. [5] S. Rainville, et al., A direct test of E=mc2, Nature 438 (2005) 1096. doi:10.1038/4381096a.305 [6] S. Eliseev, et al., Direct mass measurements of 194Hg and 194Au: A new route to the neutrino mass determination?, Physics Letters B 693 (4) (2010) 426 – 429. doi:10.1016/j. physletb.2010.08.071. [7] M. Goncharov, K. Blaum, M. Block, C. Droese,310 S. Eliseev, F. Herfurth, E. Minaya Ramirez, Y. N. Novikov, L. Schweikhard, K. Zuber, Probing the nuclides 102Pd, 106Cd, and 144Sm for resonant neutrinoless double-electron capture, Phys. Rev. C 84 (2011) 028501. doi:10.1103/PhysRevC.84.028501.315 [8] D. A. Nesterenko, et al., Double-βtransformations in isobaric triplets with mass numbers A = 124, 130, and 136, Phys. Rev. C 86 (2012) 044313. doi:10.1103/PhysRevC.86.044313. [9] G. Audi, O. Bersillon, J. Blachot, A. Wapstra, The Nubase evaluation of nuclear and decay properties, Nuclear Physics A320 729 (1) (2003) 3 – 128, the 2003 NUBASE and Atomic Mass Evaluations. doi:https://doi.org/10.1016/j.nuclphysa. 2003.11.001. [10] G. Audi, M. Wang, A. Wapstra, F. Kondev, M. MacCormick, X. Xu, B. Pfeiffer, The Ame2012 atomic mass evaluation, Chi-325 nese Physics C 36 (12) (2012) 1287. URL http://stacks.iop.org/1674-1137/36/i=12/a=002 [11] W. Huang, G. Audi, M. Wang, F. Kondev, S. Naimi, X. Xu, The AME2016 atomic mass evaluation (i). evaluation of input data; and adjustment procedures, Chinese Physics C 41 (3) (2017)330 030002. URL http://stacks.iop.org/1674-1137/41/i=3/a=030002 [12] T. Eronen, et al., JYFLTRAP: a Penning trap for precision mass spectroscopy and isobaric purification, Eur. Phys. J. A 48 (4) (2012) 46. doi:10.1140/epja/i2012-12046-1.335 [13] I. Moore, et al., Towards commissioning the new IGISOL-4 facility, Nucl. Instrum. Meth. Phys. Res. B 317 (2013) 208 – 213, XVIth International Conference on ElectroMagnetic Isotope Separators and Techniques Related to their Applications, December 27, 2012 at Matsue, Japan. doi:10.1016/j.nimb.340 2013.06.036. [14] A. Nieminen, J. Huikari, A. Jokinen, J. ¨ Ayst¨o, P. Campbell, E. Cochrane, Beam cooler for low-energy radioactive ions, Nucl. Instrum. Meth. Phys. Res. A 469 (2) (2001) 244 – 253. doi: 10.1016/S0168-9002(00)00750-6.345 [15] G. Savard, S. Becker, G. Bollen, H. J. Kluge, R. B. Moore, T. Otto, L. Schweikhard, H. Stolzenberg, U. Wiess, A new cooling technique for heavy ions in a Penning trap, Phys. Lett. A 158 (5) (1991) 247 – 252. doi:10.1016/0375-9601(91)91008-2. [16] G. Gr¨aff, H. Kalinowsky, J. Traut, A direct determination of350 the proton electron mass ratio, Z. Phys. A 297 (1) (1980) 35– 39. doi:10.1007/BF01414243. [17] M. K¨onig, G. Bollen, H. J. Kluge, T. Otto, J. Szerypo, Quadrupole excitation of stored ion motion at the true cyclotron frequency, Int. J. Mass Spectrom. Ion Processes 142 (1-2) (1995)355 95 – 116. doi:10.1016/0168-1176(95)04146-C. [18] S. George, et al., Ramsey method of separated oscillatory fields for high-precision Penning trap mass spectrometry, Phys. Rev. Lett. 98 (2007) 162501. doi:10.1103/PhysRevLett.98.162501. [19] S. George, K. Blaum, F. Herfurth, A. Herlert, M. Kretzschmar,360 S. Nagy, S. Schwarz, L. Schweikhard, C. Yazidjian, The Ramsey method in high-precision mass spectrometry with Penning traps: Experimental results, Int. J. Mass Spectrom. 264 (23) (2007) 110 – 121. doi:10.1016/j.ijms.2007.04.003. [20] M. Kretzschmar, The Ramsey method in high-precision mass365 spectrometry with Penning traps: Theoretical foundations, Int. J. Mass Spectrom. 264 (23) (2007) 122 – 145. doi:10.1016/j. ijms.2007.04.002. [21] S. Eliseev, K. Blaum, M. Block, C. Droese, M. Goncharov, E. Minaya Ramirez, D. A. Nesterenko, Y. N. Novikov,370 L. Schweikhard, Phase-imaging ion-cyclotron-resonance measurements for short-lived nuclides, Phys. Rev. Lett. 110 (2013) 082501. doi:10.1103/PhysRevLett.110.082501. [22] S. Eliseev, et al., A phase-imaging technique for cyclotronfrequency measurements, Applied Physics B 114 (1) (2014) 107–375 128. doi:10.1007/s00340-013-5621-0. [23] D. A. Nesterenko, et al., Phase-Imaging Ion-Cyclotron- Resonance technique at the JYFLTRAP double Penning trap mass spectrometer, Eur. Phys. J. A 54 (2018) 154. doi: 10.1140/epja/i2018-12589-y.380 [24] D. A. Nesterenko, et al., Direct determination of the atomic mass difference of 187Re and 187Os for neutrino physics and cosmochronology, Phys. Rev. C 90 (2014) 042501. doi:10.1103/ PhysRevC.90.042501. [25] S. Eliseev, et al., Direct measurement of the mass difference385 of 163Ho and 163Dy solves the Q-value puzzle for the neutrino 6
Page 7 of 8 Accepted Manuscript mass determination, Phys. Rev. Lett. 115 (2015) 062501. doi: 10.1103/PhysRevLett.115.062501. [26] M. Kretzschmar, On the phase dependence of the interconversion of the motional modes in a Penning trap by quadrupo-390 lar excitation, Int. J. Mass Spectrom. 309 (2012) 30 – 38. doi:10.1016/j.ijms.2011.08.022. [27] C. Roux, K. Blaum, M. Block, C. Droese, S. Eliseev, M. Goncharov, F. Herfurth, E. M. Ramirez, D. A. Nesterenko, Y. N. Novikov, L. Schweikhard, Data analysis of q-value measure-395 ments for double-electron capture with shiptrap, The European Physical Journal D 67 (7) (2013) 146. doi:10.1140/epjd/ e2013-40110-x. [28] R. T. Birge, The calculation of errors by the method of least squares, Phys. Rev. 40 (1932) 207–227. doi:10.1103/PhysRev.400 40.207. [29] F. Larkins, Semiempirical Auger-electron energies for elements 10 ≤Z≤100, Atomic Data and Nuclear Data Tables 20 (4) (1977) 311 – 387. doi:10.1016/0092-640X(77)90024-9. 7