Experimental and numerical evaluation of the compressive and shear behavior of unstabilized rammed earth
Abstract
Spanish Ministry of Universities via a doctoral grant to Fernando Ávila (FPU18/03607)
Full text
ORIGINAL ARTICLE Experimental and numerical evaluation of the compressive and shear behavior of unstabilized rammed earth Fernando A ´vila .Mario Fagone .Rafael Gallego .Esther Puertas . Giovanna Ranocchiai Received: 9 February 2023 / Accepted: 10 July 2023 / Published online: 19 July 2023 The Author(s) 2023, corrected publication 2024 Abstract Rammed earth has a longstanding tradition as a construction method and has recently gained renewed interest as an eco-friendly building technique. To employ it effectively in contemporary constructions, proper characterization of its mechanical properties and the development of predictive models become essential. Rammed earth structures usually work under compression, but their low shear strength makes this a key parameter for failure. Considering this, in the present study a mechanical characterization of rammed earth under compression and shear is carried out via laboratory tests, and the results are used to develop a numerical model (finite elements method) that can simulate rammed earth behavior under compressive and shear loads. The results show a good performance of the numerical models, accurately replicating the material behavior observed in laboratory. These numerical models are essential to predict the behavior and ensure an efficient and safe design of rammed earth structures. Keywords Unstabilized rammed earth Compressive strength Shear strength Mechanical characterization FEM Earthen construction 1 Introduction In an increasingly sustainability-conscious world, traditional construction techniques and environmentally friendly materials are gaining renewed interest from builders and researchers. One such example are the building techniques using raw earth as a primary construction material. Earth has been used as a building material for thousands of years, with several and diverse construction techniques developed all over the world [1–3]. Even today, about 30 to 40% of the world population lives in houses built with earth [3–6]. The historical and current success of this kind of constructions is due to the availability of the material at low price and their mechanical and hygrothermal properties, together with a construction processes that do not require highly specialized labor [1,7]. When earth is compacted in layers between temporary formwork, the construction method is called F. A ´vila (&)R. Gallego E. Puertas Department of Structural Mechanics and Hydraulic Engineering, University of Granada, Av. Fuentenueva, Granada 18001, Spain e-mail: [email protected] R. Gallego e-mail: [email protected] E. Puertas e-mail: [email protected] M. Fagone G. Ranocchiai Department of Civil and Environmental Engineering, University of Florence, Via di S. Marta 3, Florence 50139, Italy e-mail: [email protected] G. Ranocchiai e-mail: [email protected] Materials and Structures (2023) 56:118 https://doi.org/10.1617/s11527-023-02206-9(0123456789().,-volV)(0123456789().,-volV)
rammed earth (RE). This technique is present in several countries, used both for small houses and for bigger structures such as fortress, palaces or city walls [1,8–10]. The most traditional technique is the so-called unstabilized rammed earth (URE), which uses only water and soil, including a certain amount of clay that acts as the only binder for the mixture. In the last decades, the addition of stabilizers –mainly cement– to improve RE properties has been very common [11]. Also reinforcements based on natural and artificial fabrics have been investigated [12,13]. However, the use of stabilizers increases the environmental impact of RE (e.g. RE stabilized with 8% cement implies more than 14 times the carbon emissions and 10 times the embodied energy than the same volume of RE without stabilizers) [11], so URE is again generating growing interest as a much more eco-friendly construction technique that can still offer a very good mechanical performance [14–17]. Structural safety of traditional RE construction was based on geometrical relationships and qualitative rules, but more accurate design bases are needed nowadays in order to meet the high requirements established by construction standards. With this aim, several studies have been developed over the last years regarding the mechanical characterization of RE. Also, some authors have proposed constitutive models to represent the mechanical behavior and failure mechanisms of the material. The research, however, has been mainly focused on the compressive behavior (RE is intended to work under compression) and has been developed mostly for stabilized rammed earth (SRE), in the pursuit of finding the material with the best mechanical performance [11]. Considering the relevance of URE as a historic construction technique and its huge potential as a modern eco-friendly building method, the present study aims to develop a numerical model of RE without stabilizers that accurately reproduces its behavior both under compression and shear. As complex behavioral models need a significant amount of input data, experimental tests were developed: unconfined compression tests (UCT) on cylindrical specimens to analyze the compressive behavior – this kind of tests have been frequently carried out for RE characterization by diverse authors –, and diagonal compression tests (DCT) on larger prismatic samples to define the shear behavior and fracture and failure mechanisms. Despite the fact that tensile and shear behavior is one of the most relevant parameters in the analysis of RE failure (especially under extreme conditions) [18,19], there are very few examples in literature regarding diagonal (shear) testing of RE [5,6,20]. In a secondpart of the study, a finite elementmodel of the diagonal test was developed, defining an elastoplastic behavioral model for the material that included the mechanical properties obtained experimentally. Some other parameters that could not be assessed from the tests were obtained from literature, and then their influence was evaluated though a sensitivity analysis. 2 Experimental campaign 2.1 Materials The natural soil used in the experimental campaign of the present study comes from Seggiano (Grosseto, Italy), and can be classified, according to the European Soil Classification System (ESCS, ISO 14688-2:2018), as wellgraded sand, after been passed through an 8mm sieve in order to remove the coarser particles. The particle size distribution of the resulting earthen material – shown in Fig. 1– contains 14% clay, 31% silt, 42% sand and 13% gravel, in agreement with several recommendations for URE source materials [14,17,21,22]. The mineralogical composition of the soil is shown in Table 1;itwas determined by X-ray diffractometer, and clay mineral analysis was successively performed interpreting the variations of lattice distances related to the basal reflections that occur following specific treatments [23]. The consistency limits, maximum dry density (MDD) and optimum moisture content (OMC) where also evaluated. The soil had a plastic limit equal to 18% and liquid limit equal to 38%, leading to a plastic index of 20, according to the methodology indicated in ASTM D4318 [24]. The standard Proctor test (method C) was performed according to ASTM D698 [25], obtaining a OMC of 13% corresponding to a MDD equal to 1.83g/cm3. The geotechnical characteristics of the soil, together with its mineralogical composition, are summarized in Table 1. 2.2 Specimen manufacturing Two different types of unstabilized rammed earth specimens were prepared for the experimental tests: small cylinders (diameter 10.1cm, height 11.5cm) for 118 Page 2 of 14 Materials and Structures (2023) 56:118
the uniaxial compression tests, and large panels (50 cm 50 cm 10 cm) for the diagonal compression tests. The dimensions of the cylindrical samples were chosen in order to be able to use the Proctor mold [26] to manufacture the samples, which ensures that the soil receives the targeted compaction energy and makes the manufacturing process easily replicable. This is particularly useful considering the great variety of testing methodologies currently present in RE literature [18]. It should be noted, however, that the slenderness of these samples is lower than the usual one used for compression tests on cylindrical concrete samples (i.e. 2.0), so it may generate some variations if the results are compared to that of other studies in the literature. The prismatic samples are a scaled version of the specimens used in the standard test method for diagonal tension in masonry assemblages [27]. These reduced dimensions have already been successfully used in previous studies for the evaluation of the shear strength or RE materials [5,28]. To prepare the specimens, the natural soil was uniformly mixed with 13% water, reaching the water content equal to the OMC of the soil, in agreement with the recommendations of Walker et al. [17] and standard NZS-4298 [29]. This mixture was then poured into the molds and compacted. A 10.1cm- diameter Proctor mold was used for the cylindrical specimens, compacting the soil in three uniform layers by dropping a standard Proctor rammer (2.50kg) 25 times per layer from a height of 30.5cm, subjecting the soil to a total compactive effort of about 600kN m/m3 [25]. Although Proctor compaction tests do not apply the same energy as the one applied on a construction site, they are considered as a useful to assess the appropriate manufacturing water content for RE Fig. 1 Particle size distribution of the soil Table 1 Main mineralogical and geotechnical characteristics of the soil Mineralogical composition Geotechnical properties Quartz 27% Plastic limit 18% Calcite 25% Liquid limit 38% Clay minerals 48% Plastic index 20 – Illite 40% OMC 13% – Vermiculite 40% MDD 1.83g/cm3 – Kaolinite 20% Materials and Structures (2023) 56:118 Page 3 of 14 118
structures [17,18,30,31]. According to previous studies [18,32], results of standard Proctor tests could be more accurate when a manual rammer is used for the construction, while modified Proctor tests could fit better if pneumatic compaction is expected. A wooden formwork was manufactured for the prismatic samples, externally reinforced with steel bars to avoid undesired deformations (Fig. 2). The soil was compacted in six ca. 8.33cm-thick layers using a modified Proctor test rammer [26] (4.54kg) dropped 123 times per layer from a height of 45.7cm, in order to reach the same compactive effort per unit volume. Just after the final layer was compacted, the samples were carefully removed from the mold and stored for curing under constant ambient conditions –about 25C and 60% relative humidity– during 28 days. After 10 to 15 days of curing, the mass of the specimens reached a constant value. A total of four cylindrical samples (C1 to C4) and three panels (P1 to P3) were manufactured. The compaction process for each sample was completed within an hour after the water was added to the soil, to avoid significant moisture losses due to evaporation [33,34]. 2.3 Testing methodology The experimental part of the present study includes the evaluation of the compressive and shear behavior of the URE samples, through uniaxial and diagonal compression tests, respectively. The UCT, in the absence of specific standards for RE materials, were performed according to ASTM D1633 ‘‘Standard Test Methods for Compressive Strength of Molded Soil- Cement Cylinders’’ [35], applying a homogeneously distributed load on the upper face of the cylindrical specimens, in the direction perpendicular to the earth layers. The surfaces in contact with the bearing blocks were leveled by means of a disc grinder. A displacement-controlled testing machine was used for the test, with loading speed equal to 1.3mm/min. A specimen subjected to UCT, after failure, is shown in Fig. 3a. For the DCT, the indications of standard ASTM E519 ‘‘Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages’’ [27]. The load was applied on the top steel loading shoe, as a monotonic displacement at a rate of 1.2mm/min. The displacements along both main diagonals, in both faces, were measured by means of displacement transducers with gauge length 150mm. The setup for the DCT is shown in Fig. 3b. 2.4 Experimental results From the uniaxial compression tests, the stress–strain curves were obtained (Fig. 4); calculating the stress as the ratio between the applied load and the cross area of the sample, and the strain as the ratio between the total vertical displacement and the initial height of the specimen (i.e. stroke of the test machine). It is possible to observe an initial linear branch, where the behavior of the material can be assumed elastic, followed by another linear branch with lower slope, where the Fig. 2 Prismatic sample: compaction process (a) and manufactured specimen (b) 118 Page 4 of 14 Materials and Structures (2023) 56:118
generation and propagation of microcracks becomes more significant. A non-linear behavior continues until reaching the peak strength, followed by a softening branch until failure. Table 2shows the main parameters obtained from the UCT. At the moment of testing, the specimens had an average water content equal to 3.9%. The unconfined compressive strength (UCS) obtained in the tests is within the range usually indicated in the existing literature about URE, between 1.00 and 2.00 MPa [18]. Similar compressive strengths have been obtained by several authors for RE without stabilizers using both cubic and cylindrical specimens [36–39]. Very small dispersion between the UCS results was Fig. 3 Cylindrical specimen under UCT, after failure (a), and prismatic specimen under DCT, before failure (b) Fig. 4 Stress–strain curves from uniaxial compression tests Materials and Structures (2023) 56:118 Page 5 of 14 118
observed – coefficient of variation (CV) equal to 1.8% –, especially considering the intrinsic heterogeneity of material; which proves the effectiveness of the manufacturing and testing methodology followed in this study. Diagonal compression tests were performed on three different prismatic specimens, loading them until failure, obtaining the cracking patterns represented in Fig. 5. Cracks started approximately at the center of the specimens and spread following a diagonal orientation towards the loading shoes. Crack propagation was also conditioned by the presence of the interfaces between the earth layers. Smaller cracks also appeared, before reaching the peak load, near the interfaces at border of the panels. From the results of the DCT, the shear stress (SS½MPa) and shear strain (c½mm/mm) of the specimens were calculated, according to Eqs. 1and 2, as defined in ASTM E519 [27]. The relationship between these two parameters along the test is represented in Fig. 6. The softening branch is shorter for sample D3 because one of the gauges moved after the peak load and so further displacements could not be properly measured. Ss¼0:707P An ð1Þ c¼DxþDy gð2Þ where •Pis the applied load in N; •Anis the net area of the sample in mm2; •Dxand Dyare de displacements in the direction parallel and perpendicular to loading, respectively; and •gis the gauge length. The values obtained for these parameters in the DCT, together with the initial modulus of rigidity (G0) – calculated as the initial slope of the shear stress– strain –, are shown in Table 3. The average water content in the samples at testing was equal to 5.8%. As it happened with the UCT, the dispersion in the results is very low for the strength and higher for the modulus of rigidity and the strain. The average Ssobtained in this study, is similar to the values found in literature [19,39], although there are very few studies evaluating this parameter for URE. The shear strength of the material, according to the present study, is equal to 10% of the compressive strength. There are not relationships defined in literature between these two parameters, while the same relationship (1:10) has been found by several authors between the tensile and the compressive strength [19,37,39–41]. From the initial modulus of rigidity and Poisson’s ratio (m) it is possible to estimate the elastic modulus of an isotropic material as E¼2Gð1þmÞ. As some relevant studies have already pointed [19], although it Table 2 Results from UCT on URE cylindrical specimens Sample qtest UCS (MPa) eucs [g/cm3][MPa] [m/m] C1 1.94 1.36 0.031 C2 1.94 1.41 0.036 C3 1.95 1.41 0.034 C4 1.96 1.41 0.036 Mean 1.94 1.40 0.034 CV 2.3% 1.8% 6.8% qtest: density at testing; UCS: unconfined compressive strength; eucs: strain at maximum strength Fig. 5 Cracking patterns at failure of the URE panels in DCT 118 Page 6 of 14 Materials and Structures (2023) 56:118
might be surprising, the assumption of an isotropic material is totally acceptable for RE. Therefore, considering a value of the Poisson’s ratio equal to 0.27 [18,39,40,42], an elastic modulus of 655MPa is obtained. Values of the Poisson’s ratio of URE in literature are generally between 0.22 and 0.30 [18]; 0.27 can be considered as a value of consensus frequently used by diverse authors in previous studies [39,40,42–44]. The value of the elastic modulus equal to 655MPa is within the range usually found in URE literature, frequently between 350 and 1 000MPa [1,6,30,37,39,45–47]. The E=fcratio obtained, equal to ca. 470, is also similar to those shown in other existing studies about URE [37,43,48]. The Evalue obtained from the DCT is considerably higher than the one measured in the UCT, equal to ca. 80MPa (CV ¼22%). In fact, it has been observed that measuring the deformations directly from the displacements of the testing machine – as it was done in the UCT – significantly underestimates the stiffness of the earthen material, as the settling of the soil particles at the contact surface with the supports results in greater deformations [49,50]. It should be noted, in addition, that the enormous variability in the measurement techniques, the differences in preparation protocols for the specimens and the dispersion in the results existing in literature does not allow to define a value of consensus for the stiffness of RE. 3 Numerical analysis A numerical simulation of the diagonal compression test was carried out through finite element method (FEM). The material is modeled as continuum and homogeneous – without taking into account the existence of layers or the interaction between them – , an approach frequently used for RE, as it allows to obtain accurate results using models with lower complexity [42,44,51]. The numerical analysis Fig. 6 Shear stress–strain curves from diagonal compression tests Table 3 Results from DCT on URE panels Sample qtest (g/cm 3 )Ss(MPa) G0(MPa) css (mm/m) D1 1.90 0.15 236.5 4.92 D2 1.93 0.14 251.3 2.93 D3 1.92 0.14 288.2 2.82 Mean 1.92 0.14 258.6 3.56 CV 1.1% 3.2% 10.3% 33.2% qtest: density at testing; Ss: shear strength; G0: initial modulus of rigidity; css: shear strain at maximum strength Materials and Structures (2023) 56:118 Page 7 of 14 118
described in the present study was carried out using FEM software Abaqus v.2022 [52]. 3.1 Constitutive law The continuum, plasticity-based, damage model ‘‘concrete damage plasticity’’ (CDP), implemented in Abaqus, was used to describe the behavior of the material. CDP is based on the constitutive model proposed by Lubliner et al. [53], with the modifications introduced by Lee and Fenves [54]. Although it was initially designed for concrete, its characteristics – such as the different yield strengths in tension and compression and the fact that it assumes that the main two failure mechanisms are tensile cracking and compressive crushing of the material – make it particularly suitable for advanced macroscopic modeling of brittle and quasi-brittle materials [22,55,56]. The uniaxial stress–strain relations used in the CDP model are shown in Fig. 7. This behavioral model uses a Drucker-Prager surface as multidimensional strength domain, which can be modified by a factor Kc(ratio of the second stress invariant on the tensile meridian), that allows to deform the failure surface, with Kc¼1 meaning a circular yield surface in the deviatoric plane. Other parameters defining the CDP model are the flow potential eccentricity (), representing the rate at which the flow potential function approaches the asymptote (when the eccentricity tends to zero the function tends to a straight line); the biaxial strength ratio (rb0=rc0); the viscosity parameter (l); and the dilation angle (u). The values of these parameters considered in the present study are shown in Table 4 and were defined following the recommendations present in literature for RE modeling [22,55,56] and in Abaqus documentation [57]. For the dilation angle, it was analyzed that varying its value from 0to 20 had a negligible effect on the stress–strain behavior of the material. Together with these general parameters, Abaqus’ CDP model requires the definition of the elastic properties of the material and the inelastic compressive and tensile behavior. For the RE material analyzed in the present study, an elastic modulus of 655 MPa—obtained from the experimental DCT— was considered, with a Poisson’s ratio assumed equal to 0.27, according to literature, as previously indicated. For the compressive behavior, the inelastic stress– strain data obtained in UCT was introduced. The tensile behavior of the material was defined by specifying the fracture energy and the tensile strength, assuming a linear loss of strength after cracking [58,59]. The value of these parameters were assessed through a sensitivity test on the model. 3.2 Finite elements model The FEM model for the DCT comprised three parts: a 50 cm 950 cm 910 cm prism with CDP behavioral model—as described in the previous section—representing the URE sample, and two L-shaped loading shoes defined as rigid solids. The contact surface Fig. 7 Stress–strain curves in the CDP model under uniaxial loading in compression (a) and tension (b) [57] 118 Page 8 of 14 Materials and Structures (2023) 56:118
between the loading shoes and the panel was defined with a ‘‘hard’’ contact normal behavior plus a penalty (friction) tangential behavior [60], with friction coefficient equal to 0.2. A sensitivity analysis was carried out for this friction coefficient, observing that changes near to the chosen value of 0.2 had a negligible effect on the general behavior of the model, while much higher values produced an abnormal behavior in the zone near the shoe-sample contact. The loading shoes had all displacements constrained but the vertical displacement of the top shoe; this displacement was monotonically incremented up to a value of 5.0mm, so that the significant region of the load–displacement equilibrium path was covered. Eight-node linear brick elements were used, and a static analysis was performed. Figure 8shows the geometry of the finite element model for the DCT in Abaqus. 3.3 Calibration and results The model was evaluated varying the two parameters that describe the tensile behavior of the CDP material model (i.e. tensile strength and fracture energy) in order to assess their effect. For the tensile strength, according to the results in literature, values between 0.14 MPa (10% of the UCS) and 0.17 MPa were assumed [6,37,39–41]. For the fracture energy, there is not much information in URE literature, but some authors show results between 10 and 20 N/m [40,45,61]; while Abaqus recommends using typical values from 40 to 120 N/m [57] (as the model is originally designed for concrete). Considering this, the model was analyzed for fracture energy values equal to 10, 20, 30 and 40 N/m. The results (shear strengthstress curves) obtained simulating the DCT for all the possible combinations of these two parameters are shown in Fig. 9. It can be observed that the first part of the Ssc curve, corresponding to the elastoplastic branch for increasing load, fits very well with the experimental results and does not vary when modifying the tensile parameters of the model, as the material here is mostly under compression. Before reaching the maximum load, when the behavior becomes more plastic and tension-dependent, the shape of the curves highly depends on the Gfand ftvalues. Increasing the fracture energy increases the peak shear strength and the corresponding shear stress. Also, high Gfvalues lead to a smooth softening branch, while low values cause a fast decrease of the stress after the peak load. The tensile strength, on the other hand, does not significantly affect the post-peak behavior, but increases the maximum shear stress reached. The shear strain at which this stress is reached is also increased but not that much. According to these results, a fracture energy in the CDP model of at least 20 N/m is required to reach the experimental peak stress, and Gf¼40 N/m is needed to properly represent the post-peak behavior. At the same time, tensile strengths between 0.15 and 0.16MPa were able to provide a good adjustment of the curve at the peak strength and for the values around this maximum. With these Gfand ftvalues, the model reached a maximum shear stress of ca. 0.14 MPa at a shear strain between 3.2 and 4.0 mm/m, very close to the values obtained in the laboratory tests. Also the rest of the Ssccurves show a behavior similar to the one observed experimentally. The failure mode obtained with the FEA was evaluated and compared with the one observed experimentally. The ‘‘tensile equivalent plastic strain’’ Table 4 Parameters used in the CDP model Parameter Value Kc2/3 0.1 rb0=rc01.16 l0.001 u10 Fig. 8 Finite elements model for diagonal compression test Materials and Structures (2023) 56:118 Page 9 of 14 118