scieee AI-readable full text Open interactive document viewer

Automated operational modal analysis and ambient noise deconvolution interferometry for the full structural identification of historic towers: A case study of the Sciri Tower in Perugia, Italy

García Macías, Enrique,Ubertini, Filippo

Full text

Automated operational modal analysis and ambient noise deconvolution interferometry for the full structural identification of historic towers: A case study of the Sciri Tower in Perugia, Italy Enrique Garc´ ıa-Mac´ ıasa,∗, Filippo Ubertinia aDepartment of Civil and Environmental Engineering, University of Perugia, Via G Duranti 93, Perugia 06125, Italy Abstract Structural Health Monitoring (SHM) based upon Operational Modal Analysis (OMA) constitutes an increasingly mature and widespread technology in the conservation of historic structures. Such techniques, while proved effective for assessing the global integrity of structures, may fail at detecting local damage with little influence on the modal features of the system. In this context, the analysis of propagating waves throughout the structure features a synergistic approach to OMA with superior capabilities for data-driven damage identification. Although some promising results have been reported in the literature on the application of Seismic Interferometry to reinforcedconcrete structures, works concerning the continuous monitoring of ambient vibrations in historic structures are virtually non-existent. In this light, this paper proposes the coupled application of automated OMA and Ambient Noise Deconvolution Interferometry for the full structural system identification of historic structures, and evaluates the advantages of this technology through a validation case study of the Sciri Tower in Perugia, Italy. A continuous vibration-based monitoring system deployed in the tower during three weeks allows us to assess the effectiveness of the proposed approach. The reported results demonstrate the robustness of the monitoring system for identifying environmental effects on the spatial distribution of wave velocities, and shed light into the dispersion relation of the tower. Keywords: Ambient vibration testing, Automated Operational Modal Analysis, Seismic Interferometry, Structural Health Monitoring, Wave propagation 1. Introduction1 Structural Health Monitoring based on output-only or OMA has become a mature and ubiquitous technology2 in the preventive maintenance of structures. These techniques exploit ambient acceleration records to extract the3 modal properties of the structure as damage sensitive features [1–3]. Given that these systems work under oper-4 ational conditions, the degree of invasiveness and impact on the monitored structure are minimal [4–7], so their5 implementation in Cultural Heritage (CH) structures has become particularly popular (see e.g. [8–12]). Due to the6 sensitivity of the modal properties to environmental factors, such as temperature or humidity [13, 14], damage is7 often masked by daily modal fluctuations, so long-term monitoring schemes are essential to fully exploit the poten-8 tial of modal-based damage detection techniques. In this wise, automated OMA techniques allow the continuous9 and remote assessment of the structural health, maximizing their capability for early damage detection through10 novelty analysis and improving their usefulness for decision-making in maintenance and rehabilitation activities.11 Nevertheless, while proved highly effective for interrogating the global integrity of structures, these techniques12 may be inefficient in detecting local damage with little influence on the modal features of the system. More-13 over, the localization of local structural pathologies usually requires the inverse calibration of a numerical model14 which, in the case of historical buildings, may be computationally demanding and incompatible with continuous15 monitoring systems. In this context, seismic interferometric techniques represent a synergistic approach to OMA16 with superior capabilities for data-driven damage identification. Nonetheless, while a few promising results have17 been reported in the literature on its application for earthquake-induced damage detection of reinforced-concrete18 structures, works coping with the use of Seismic Interferometry for the continuous monitoring of structures under19 ambient conditions are very scarce, and practically non-existent in the realm of historic buildings.20 Seismic interferometry conceives the response of a dynamic system as a superposition of propagating waves,21 and exploits the wave velocities between pairs of sensors as damage sensitive features [15–17]. The fundamentals22 ∗Corresponding author. Email address: [email protected] (Enrique Garc´ ıa-Mac´ ıas) Preprint submitted to Engineering Structures April 17, 2020 of this approach lie in the fact that scattering and attenuation of propagating pulses depend upon the constitu-23 tive properties of the medium and, therefore, the identification of wave velocities provides an indirect evaluation24 of the intrinsic stiffness of the system [18]. To do so, travelling waveforms can be described by means of im-25 pulse response functions (IRFs) computed at different monitored locations throughout the structure. Specifically,26 IRFs obtained by deconvolution interferometry have proven well-suited for the monitoring of mono-dimensional27 structures such as buildings or towers [19, 20]. Recent research works report promising advantages of seismic28 interferometric techniques compared to OMA-based approaches. In the first place, damage identification based29 upon Seismic Interferometry is local in essence, since damage-induced stiffness deterioration leads to localized30 increases in the pulse travel times across the damaged part of the structure [21–23]. Most interestingly, damage31 identification (detection, localization and, to some extent, quantification) can be performed in a fully data-driven32 way simply by peak-picking analysis of IRFs [24]. A second distinctive feature of these techniques regards the33 possibility of investigating soil-structure interaction (SSI) properties through the analysis of the dispersion of seis-34 mic waves [25–27]. Dispersive media are characterized by the variation of phase velocities with frequency. It35 has been reported that the contribution of bending deformation to the dynamic response of the structure (as it is36 usually the case of high-rise buildings), as well as SSI effects, increase the dispersion of seismic waves [27, 28].37 Nevertheless, as demonstrated by the work of Rahmani et al. [27], wave velocities estimated from broader band38 IRFs (including at least two modes of vibration) show almost no sensitivity to the SSI, and primarily provide39 information about the specific condition of the building irrespective of the boundary conditions at the foundation.40 The broad majority of research on the application of Seismic Interferometry to structural system identifica-41 tion has focused on reinforced-concrete (RC) buildings under seismic actions. The assessment of wave travel42 times using IRFs was first proposed by Snieder and S¸afak [17], who studied the wave propagation properties43 of the 9-storey RC Millikan Library in Pasadena (Los Angeles, US) during the Yorba Linda Mw4.3 earthquake44 in 2002. Their results showed that the IRFs reflect well the propagation mechanisms of seismic waves across45 the building, reporting acausal upgoing and downgoing (reflected) pulses when the deconvolution is referenced46 to the roof level, and only causal pulses propagating upward when referenced to the base. A similar methodol-47 ogy was applied by Todorovska and Trifunac [29] for the analysis of the Van Nuys 7-story hotel under different48 earthquakes. Specifically, their results demonstrated considerable wave delays (decrease in stiffness) during the49 1994 Northridge and 1971 San Fernando earthquakes, which agree well with the observed damage by separate50 inspections. Those authors also investigated the effects of the Imperial Valley Earthquake of 1979 on the wave51 propagation properties of a 6-storey RC building in El Centro (California, US) [22], and their results reported52 good agreements between the wave delays obtained by peak-picking of IRFs and the actual earthquake-induced53 damage. Rahmani and Todorovska [30] proposed an SHM system based on the fitting of wave velocity profiles54 by the inverse calibration of an equivalent layered shear beam model. Their results showed that, given that the55 calibration essentially involves phase differences between motions at different floors of the building, the identified56 velocity profile is minimally affected by SSI and, therefore, provides a superior damage-sensitive feature compared57 to OMA-based approaches. Nonetheless, although most of the mechanisms underlying the propagation of seismic58 waves in multi-storey buildings could be explained, the shear beam model failed to reproduce the observed disper-59 sion effects. In order to address this issue, Ebrahimian and Todorovska [28, 31] developed a layered Timoshenko60 beam (TB) model accounting for both shear and bending deformation effects for wave propagation analysis. Their61 results demonstrated the contribution of bending deformation to the dispersion of travelling waves. The resulting62 dispersion relation (phase velocity versus frequency) was proved monotonically increasing with frequency, with63 largest velocity variations at low frequencies and stable values at high frequencies. Interestingly, those authors64 also reported the existence of two propagating modes with different phase velocities in high-rise buildings. Below65 a certain critical frequency depending on the material properties and geometry of the building, one single mode66 defines the wave propagation, while both modes determine the waveforms above this cut-offfrequency generating67 complex interference patterns. Recently, the authors [32] extended the TB formulation to investigate the appli-68 cation of acceleration- and strain-based wave propagation analysis for damage identification in masonry towers69 under seismic actions. Using pseudo-experimental records generated by a non-linear 3D numerical model, the re-70 ported results demonstrated that the inverse calibration of the TB model allows relating identified damage-induced71 wave delays to local stiffness losses in the structure.72 The number of works on the use of Deconvolution Interferometry for the system identification of structures73 under ambient vibrations is considerably lower. Among them, a noteworthy contribution is the work by Prieto et74 al. [33] who applied Ambient Noise Deconvolution Interferometry (ANDI) for the system identification of the 17-75 storey steel moment-frame UCLA Factor building located at the University of California. In that work, IRFs were76 generated from ambient noise by means of a deconvolution approach with temporal averaging. A similar technique77 was also used by Nakata and Snieder [34] for the monitoring of an 8-storey building in Japan. Interestingly, their78 results showed that ambient noise IRFs are characterized by causal and acausal pulses when deconvolution is79 referenced to both the base and the roof levels. Such a behaviour, unlike the case of seismic excitation, is due80 2 to the presence of several excitation sources throughout the building (e.g. micro-tremors, human actions, wind81 loadings). Bindi et al. [35] conducted ambient vibration tests (AVTs) on an 8-storey RC hospital in Thessaloniki82 (Greece), and explored the simultaneous application of ANDI and Frequency Domain Decomposition (FDD).83 Their results suggested the possibility of developing SHM systems based upon the synergistic application of OMA84 and ANDI for full system identification. In this regard, Lacanna et al. [36] conducted a pioneering application85 of continuous OMA and ANDI for structural assessment of the Giotto’s bell-tower in Florence, Italy. Despite86 reporting some limitations for the identification of environmental effects on the wave velocities due to insufficient87 sampling frequency and short monitoring time, their results evidenced the superior capabilities of SHM systems88 based on automated OMA/ANDI for damage detection, localization, and quantification. Recently, the authors89 reported in reference [37] the synergistic application of OMA and ANDI for the full dynamic identification of90 three different architectural heritage structures using AVTs, including the Sciri Tower in Perugia, the Consoli91 Palace in Gubbio, and the bell-tower of the Basilica of San Pietro in Perugia. While promising, the reported results92 highlighted the existence of substantial environmental effects on the identified wave velocities, and thereby discrete93 AVTs are often ineffective to extract damage sensitive features. In these cases, the continuous monitoring of94 structures and the characterization of environmental effects become imperative for performing pattern recognition95 and effective damage identification, as addressed in this work.96 In light of the previous state-of-the-art review, this paper proposes the coupled application of automated OMA97 and ANDI for the full structural system identification of historic structures, and evaluates the advantages of this98 technology through a validation case study of the Sciri Tower in Perugia, Italy. This case study represents a stan-99 dard example of a masonry tower inserted into a building aggregate, and a continuous vibration-based monitoring100 system installed in the tower during three weeks allows us to assess the effectiveness of the proposed approach.101 The reported results evaluate the robustness of the monitoring system for identifying environmental effects on the102 spatial distribution of wave velocities, and shed some light into the dispersion relation of the tower.103 The remaining of this paper is organised as follows. Section 2 describes the Sciri Tower and the monitoring104 system installed in the structure. Section 3 presents the system identification results obtained by automated OMA.105 Section 4 reports the results obtained by ANDI, and investigates the environmental effects of the wave velocity106 profiles in two orthogonal directions of the tower and, finally, Section 5 concludes this work.107 2. Description of the Sciri Tower and testing set-up108 The Sciri Tower (Torre degli Sciri) is a 41 m high civic tower located in the historical centre of Perugia in Italy.109 Its construction dates back to the late 13th century and, nowadays, the Sciri Tower is the only one preserved intact110 among the numerous towers erected during the medieval period of the city. The tower was owned by the noble111 family of Oddi until 1488, when it was transferred to the Sciri family (who gave it its current name) after violent112 disputes between noble clans that forced the Oddi family into exile. In 1680, the tower and the adjoining building113 were gifted to the Franciscan Third Order until 2011, when the ensemble became property of the Municipality of114 Perugia. Important conservative restoration works were conducted in the building ensemble by the municipality115 in 2015, although neither the building aggregate nor the tower experienced significant structural modifications.116 The Sciri Tower is inserted into a building ensemble with approximate plan dimensions of 22 ×25 m. The117 tower is made of homogeneous squared white limestone blocks and has a hollow rectangular cross-section of118 7.15 ×7.35 m, with three fac¸ades connected to the adjacent masonry buildings up to a height of 17 m, and a119 fourth one remaining unconstrained all along its height. The tower can be ideally split into two structural portions120 beneath and above the height level of 8.4 m. The lower part has wall thicknesses between 1.68 m and 2.1 m, and121 culminates with a stone masonry vaulted slab standing over an old chapel. On the other hand, the upper part has122 slender continuous walls (with thickness varying in height from 1.6 m to 1.4 m), and houses a metal staircase123 resting on four 1.5 m wide masonry vaulted slabs at different heights. Finally, a brick masonry ceiling vault124 completes the tower, and a 0.5 m thick parapet along the edges of a panoramic terrace rises up to a total height of125 41 m.126 3 2 1 3 D A Q z=36.7 m Thermocouples 4z=32.9 m 6 5 z=28.4 m 7 8 12 10 9 11 z=24.3 m z=16.9 m z=9.3 m DAQ Sensor N Wi-Fi antenna SE NE Figure 1: Layout of the dynamic monitoring system installed in the Sciri Tower with sensors positions (labelled from 1 to 12). With the aim of identifying the modal features and wave propagation properties of the Sciri Tower, a continu-127 ous ambient vibration testing was performed for three weeks, from February 13th until March 10th 2019. To this128 end, a total of 12 high sensitivity (10 V/g) uniaxial PCB 393B12 accelerometers were installed at four different129 heights of the tower, namely z=40.5 m, z=33.5 m, z=24.0 m and z=8.4 m, as shown in Figure 1. Ambient130 vibrations were recorded at three different sampling frequencies to evaluate the robustness of the wave identifica-131 tion, including 200 Hz, 1000 Hz, and 5000 Hz. In addition, two K-type thermocouples were also installed at the132 level z=40.5 m (indoor and outdoor) and temperature was recorded at a sampling frequency of 0.4 Hz. Field data133 were acquired using a multi-channel data acquisition system (DAQ) model NI CompactDAQ-9184 located at the134 level z=36.7 m, equipped with NI 9234 data acquisition modules for accelerometers (24-bit resolution, 102 dB135 dynamic range and anti-aliasing filters) and NI 9219 modules for thermocouples (24-bit resolution, ±60 V range,136 100 S/s). A LabView toolkit was implemented for data acquisition and preliminary real-time processing, includ-137 ing amplitude and spectral plots for quality-control inspections. Data were recorded in separate files containing138 30-min long acceleration and temperature time series, and transferred in real-time through Wi-Fi connection to139 the Laboratory of Structural Dynamics of the University of Perugia, 2.5 km far from the tower. Here, data were140 stored and processed with the purpose of extracting the dynamic characteristics of the tower, including its modal141 properties and wave propagation velocities. Figure 2 shows a flowchart of the automated OMA and ANDI system142 implemented in the Sciri Tower, the details of which are described hereafter.143 4 DAQ Signal Pre-processing OMA ANDI Noise modes elimination Clustering analysis Frequency tracking Wave velocity tracking Transfer functions Band-pass filtering IRFs Peak-picking analysis Laboratory of Structual Dynamics University of Perugia Sciri Tower COV-SSI [ jb,min , jb,max ] Δjb [ nmin , nmax ] Δn Figure 2: Flowchart of the automated OMA and ANDI system implemented in the Sciri Tower. 3. Automated Operational Modal Analysis144 3.1. Automated OMA algorithm145 The Covariance-driven Stochastic Subspace Identification (COV-SSI) method [38] has been used to perform146 the online OMA of the Sciri Tower. In particular, an in-house fully automated OMA code has been implemented in147 MATLAB environment following an automation approach equivalent to the one proposed by Ubertini et al. [39].148 This consists of three consecutive steps as sketched in Fig. 2, including iterative modal identification (i), noise149 modes elimination (ii), and clustering analysis (iii). The first step consists of performing the modal identification150 considering an interval jb,min,jb,maxwith steps of size ∆jbof the number of blocks of the Toeplitz matrix in the151 COV-SSI method, as well as an interval of model orders [nmin,nmax]with steps of size ∆n. This procedure results152 in a set of Mpoles, whose modal information can be organized in matrix form as:153 f=f1f2. . . fMT, ζ=ζ1ζ2. . . ζMT, Θ=[Θ1Θ2. . . ΘM], (1) where fm,ζm, and Θmdenote the frequency, damping, and mode shape vector of an arbitrary m-th mode, m=154 1,2,...,M. Afterwards, a noise modes elimination algorithm is implemented in order to automate the analysis of155 the multiple resulting stabilization diagrams. This algorithm discerns between noise modes and physical ones by156 assessing the frequency of appearance of the system poles over all the identification analyses. To do so, a vector157 c=[c1c2. . . cM]Tis constructed, whose components cm,m=1,2,...,M, are given by:158 cm=−1+PM l=1δlm,if ζm∈0ζmax 0,if ζm<0ζmax(2) with159 5 δlm = 1,if ∆flm ≤f,∆ζlm ≤ζ,1−MAClm ≤MAC 0,otherwise ∆flm =|fl−fm| fm ,∆ζlm =|ζl−ζm| ζm ,MAClm =MAC(Θl,Θm), (3) where ζmax is the maximum admissible value for the damping ratio of the physical modes, MAC(Θl,Θm) is the160 Modal Assurance Criterion (MAC) value between modes Θland Θm, and f,ζ, and MAC are user-defined tol-161 erances. A generic component, cm, indicates the number of modes with frequencies, damping ratios, and mode162 shapes similar to those of the m-th mode among all the Midentified ones. Therefore, the m-th mode is said to be163 stable when its frequency of appearance given by cmis larger than a certain fraction sof the total number of modal164 identification analyses N, i.e. cm≥sN. Then, the number of stable poles can be readily obtained computing a165 vector S:166 S=[S1S2. . . SM]T, Sm= 1,if cm≥sN =sjb,max−jb,min ∆jb+1nmax−nmin ∆n+1 0,otherwise (4) whose components Smassign 0 and 1 to unstable and stable modes, respectively. Consequently, the total number167 of stable modes, P, simply reads P=PM l=1Sl. The vectors of stable frequencies fsand damping ratios ζs, and the168 matrix of stable mode shapes Θscan be extracted as:169 fs=HE f =f1f2. . . fPT, ζs=HE ζ=ζ1ζ2. . . ζPT, Θs=HE ΘTT=[Θ1Θ2. . . ΘP], (5) where HE is a P×Mmatrix whose non-zero components are HEp,πp=1, p=1,2,...,P, with π1, π2, . . . , πp 170 being the positions of the non-zero terms of vector S.171 Finally, an agglomerate hierarchical clustering algorithm is implemented to group the previously extracted P172 stable modes into a set of homogeneous data clusters pertaining to the same structural mode. Interested readers173 may refer to reference [38] for further details on the implemented clustering analysis procedure.174 3.2. Initial ambient vibration test175 The identification results of the first 30-min long vibration records, taken on February 13th 2019 at 2:00 pm176 and down-sampled to 40 Hz, are presented in Fig. 3 and Table 2. The raw data were initially pre-processed by177 subtracting the temporal mean and applying time-domain Hanning filtering to eliminate undesired noise sources178 such as spikes related to electrical interferences. For validation purposes, Table 2 collects the identified natural179 frequencies and damping ratios obtained by four different OMA methods, namely the COV-SSI, Eigensystem Re-180 alization Algorithm (ERA), poly-reference Least Squares Complex Frequency-domain (p-LSCF), and Enhanced181 Frequency Domain Decomposition (EFDD) methods [38]. The input parameters used in the considered identifica-182 tion methods are collected in Table 1. The ERA method has been implemented following an automated procedure183 identical to the one previously reported in Section 3.1, with jbdenoting in this case the number of block rows184 and columns of the Hankel matrix of the cross-correlation functions. Readers are referred to the Supplementary185 Material for further details on the OMA of the Sciri Tower.186 Seven vibration modes have been identified in the frequency range between 0 and 12 Hz, including two flexu-187 ral modes in the NE direction (Fx1 and Fx2), two flexural modes in the SE direction (Fy1 and Fy2), one torsional188 mode (Tz1), and two higher order flexural modes, (Fx3 and Fy3). It is noted in Table 2 that all the identification189 methods yield very close estimates of the resonant frequencies with relative differences below 2%. Nevertheless,190 considerable discrepancies can be observed in terms of damping ratios between the time-domain (COV-SSI and191 ERA) and frequency-domain (p-LSCF and EFDD) identification methods. The frequency-domain methods report192 considerably smaller damping ratios, with values even below 0.2% which are assumed as unidentified damping193 values. In particular, the p-LSCF method failed to identify the damping ratios of modes Fx3 and Fy3. It is well-194 known in the literature that, while very clear stabilization diagrams are obtained with the p-LSCF method, this195 technique tends to underestimate the damping parameters of low-excited modes with high noise levels [40], as it196 6 is the case of most historic masonry structures. Advanced system identification methods such as the combination197 of the maximum likelihood estimator and the p-LSCF method (ML-pLSCF, see [41]) have been reported to al-198 leviate such limitations. Finally, it is noted that the EFDD method yields unrealistically low damping ratios for199 modes Fy2, Tz1, Fx3 and Fy3, which is due to a poor representation of their single mode bell functions and the200 corresponding correlation functions. This issue is also conceivably due to an insufficient excitation levels for these201 modes.202 In light of the previous discussion, the COV-SSI method is used in this work in all the subsequent analyses.203 The corresponding mode shapes obtained by COV-SSI are depicted in Fig. 3. In this figure, complexity plots of204 the identified mode shapes are also shown, where each arrow represents a component of the mode shape vectors.205 The more collinear the components are the more the system is classically (proportionally) damped in that mode.206 Conversely, scatters in the complexity plot may indicate that the system is non-classically damped in that mode, or207 may evidence the presence of limiting factors in the identification, such as low signal-to-noise ratios, estimation208 or modelling errors. It is noted in Fig. 3 that modes Fx1, Fy1, Tz1, Fx3 and Fy3 are identified as almost perfectly209 classically damped, while some scatter can be observed in the remaining modes, particularly in mode Fy2.210 Table 1: Input parameters of the modal identification methods used in the Sciri Tower. COV-SSI [nmin,nmax]=[40,80], ∆n=1 [jb,min,jb,max]=[140,200], ∆jb=10 ζmax =10%, s=5% f=0.05, ζ=0.01, and MAC =0.01 ERA [nmin,nmax]=[40,80], ∆n=1 [jb,min,jb,max]=[100,160], ∆jb=10 ζmax =10%, s=5% f=0.05, ζ=0.01, and MAC =0.01 p-LSCF [nmin,nmax]=[200,300], ∆n=1 Cross half-spectra by the Welch’s method: 213 data points with 50% overlap EFDD Spectral density matrix by the Welch’s method: 211 data points with 50% overlap Single-Input-Single-Output (SISO) version of the Ibrahim Time Domain (ITD) method 7 Mode Fx1 Mode Fy1 Mode Fx2 Mode Fy2 Mode Tz1 Mode Fx3 Mode Fy3 Sensors layout x y N Figure 3: Experimentally identified mode shapes estimated through COV-SSI on February 13th 2019 at 14:00 UTC. Table 2: Experimentally identified natural frequencies, fi, and damping ratios, ζi, using the COV-SSI, ERA, p-LSCF and EFDD methods on February 13th 2019 at 2:00 pm. COV-SSI ERA p-LSCF EFDD Mode fexp i[Hz] ζi[%] fexp i[Hz] ζi[%] fexp i[Hz] ζi[%] fexp i[Hz] ζi[%] Fx1 1.692 0.921 1.691 0.838 1.691 0.622 1.691 0.819 Fy1 1.891 0.767 1.890 0.791 1.891 0.559 1.888 0.751 Fx2 5.447 5.002 5.440 5.547 5.531 0.749 5.476 0.605 Fy2 5.819 2.044 5.822 2.114 5.846 0.211 5.810 - Tz1 8.206 1.787 8.212 1.938 8.190 0.725 8.159 - Fx3 9.789 1.333 9.789 1.446 9.796 - 9.740 - Fy3 10.824 3.134 10.858 3.410 10.770 - - - 3.3. Continuous OMA of the Sciri Tower211 The vibrational modes of the Sciri Tower previously presented in Fig. 3 and Table 2 have been continuously212 identified and tracked by the COV-SSI method throughout the monitoring period. To do so, the 30-min long vibra-213 tion records have been down-sampled to 40 Hz, and the modal features have been extracted using the automated214 OMA procedure previously introduced in Section 3.1. Figure 4 shows the time histories of the natural frequencies215 of the first seven modes of the tower continuously identified and tracked throughout the monitoring period since216 February 13th until March 10th 2019. In this figure, the temperature time series recorded by the two thermocouples217 (indoor and outdoor) are also shown. Clear day-night oscillations can be found in all the natural frequencies, with218 increases during daytime and decreases during night-time. Figure 5 further investigates the effects of environ-219 mental temperature on the resonant frequencies of the tower. It is noted that there is a positive correlation of all220 the frequencies with temperature, that is, increasing temperatures yield increasing natural frequencies and vice221 versa. Such a behaviour is often found in historic structures, where the thermal expansion of masonry originates222 the closure of superficial cracks or micro-cracks, as well as minor discontinuities in the structure [42]. Finally, it is223 8 observed that the thermal sensitivity of the resonant frequencies, given by the slope of the linear fittings included224 in Fig. 5, is larger for higher-order modes.225 5 10 15 Temp. [◦] Indoor Outdoor 13/Feb/19 14/Feb/19 15/Feb/19 16/Feb/19 17/Feb/19 18/Feb/19 19/Feb/19 20/Feb/19 21/Feb/19 22/Feb/19 23/Feb/19 24/Feb/19 25/Feb/19 26/Feb/19 27/Feb/19 28/Feb/19 01/Mar/19 02/Mar/19 03/Mar/19 04/Mar/19 05/Mar/19 06/Mar/19 07/Mar/19 08/Mar/19 09/Mar/19 10/Mar/19 2 4 6 8 10 12 Frequencies [Hz] Fx1 Fy1 Fx2 Fy2 Tz1 Fx3 Fy3 1.68 1.7 1.72 Fx1 [Hz] 1.88 1.9 Fy1 [Hz] 5.4 5.5 5.6 5.7 Fx2 [Hz] 20/Feb/19 21/Feb/19 22/Feb/19 5.7 5.8 5.9 6 Fy2 [Hz] Daytime Night-time Figure 4: Temperature time series and frequency tracking in the Sciri Tower since February 13th until March 10th 2019. 2610 14 1.62 1.66 1.7 1.74 Temp. [◦] Fx1 [Hz] 2610 14 1.84 1.86 1.88 1.9 1.92 1.94 Temp. [◦] Fy1 [Hz] 2610 14 5.4 5.45 5.5 5.55 5.6 5.65 Temp. [◦] Fx2 [Hz] 2610 14 5.6 5.7 5.8 5.9 6 Temp. [◦] Fy2 [Hz] 2610 14 7.8 7.9 8 8.1 8.2 8.3 8.4 8.5 Temp. [◦] Tz1 [Hz] 2610 14 9.3 9.4 9.5 9.6 9.7 9.8 9.9 10 10.1 Temp. [◦] Fx3 [Hz] y=1.65+4.4E-3x y=1.85+3.7E-3x y=5.43+11.3E-3x y=5.63+21.6E-3x y=7.90+27.3E-3x y=9.37+27.3E-3x Figure 5: Identified natural frequencies versus outdoor temperature. 4. Automated Ambient Noise Deconvolution Interferometry226 This section reports the results of the wave propagation analyses conducted in the Sciri Tower by ANDI. Seis-227 mic interferometry is based upon the assessment of travelling pulses and the spatial distribution of their velocity by228 means of the analysis of transfer functions (TFs). A transfer function b h(z, ω) can be defined as the deconvolution229 of a reference input signal u(zre f , ω) recorded at a reference station zre f with an output signal u(z, ω) recorded at230 an arbitrary station z, and is typically computed in the angular frequency domain ωas [20, 22, 43]:231 b h(z, ω)=u(z, ω)u(zre f , ω) u(zre f , ω)2+ ,(6) 9 where A(z, ω) is an amplitude spectrum and contains the information about attenuation, spherical divergence and359 source spectrum characteristics. Since the amplitude does not contain any information linked to the phase velocity,360 the following integral transformation is applied to h(z, ω):361 V(ω, φ)=Zeiφz[h(z, ω)/|h(z, ω)|]dz=Ze−i(k−φ)z[A(z, ω)/|A(z, ω)|]dz.(10) Such an integral transform can be understood as the sum over offset of wavefields of a frequency after applying362 offset-dependent phase shifts defined by assuming a phase velocity cph =ω/φ. Therefore, for a given frequency363 ω,V(ω, φ) presents a maximum if φ=k. Dispersion images can be extracted by considering a discrete sampling364 of the frequency range of interest, as well as of the search space of phase velocities, and mapping the values365 of V(ω, φ) in a 2D format (i.e., phase velocity cph =ω/φ versus frequency ω). In this bi-dimensional graph,366 dispersion curves can be traced by following the peaks along the frequency axis.367 The previously outlined MASW method has been applied to the ambient vibrations recorded in the Sciri Tower368 along the SE direction and the results are shown in Fig. 11. To do so, wave velocities between 50 and 2000 m/s369 have been scanned with a velocity step of 1 m/s, and frequencies between 1 and 50 Hz have been sampled every370 0.33 Hz. The analysis has been performed considering 3 s long IRFs (-1.5 s<t<1.5 s) obtained with a sampling371 frequency of 200 Hz and staked over the first 48 hours. In order to take into account the inherent limitations372 of the sensor array to characterize the dispersion properties, theoretical bounds have been included in Fig. 11373 (yellow dashed lines). According to the work of Cornou et al. [46], these correspond to the range of acceptable374 wavelengths λgiven by λmin ≤λ≤λmax, with λmin =2dbeing the spatial aliasing limit, and λmax =3Dthe375 maximum capability of the sensor array to separate two waves propagating at closely spaced wavenumbers, and376 d=3.8 m and D=27.4 m the minimum and maximum inter-station distances, respectively. Additionally, the377 wave velocities previously computed by peak-picking analysis in Table 4 have been also included herein. It is378 noted that the wave velocities estimated by peak-picking analysis follow the first region of peaks of V(ω, cph).379 Nevertheless, there is a second region of large V(ω, cph) values for frequency values above approximately 17 Hz380 that cannot be explained by peak-picking analysis, what may evidence the presence of a second wave propagation381 mode. In fact, the change in the variation rates of the wave velocities previously reported in Table 4 between 15382 and 20 Hz may be indicative of a bias towards this second propagation mode.383 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 Normalized amplitude Peak picking estimates 10 20 30 40 50 200 400 600 800 1000 1200 1400 1600 1800 2000 Frequency [Hz] Phase velocity [m/s] c1 ph c2 ph fcr 3Df 2df Figure 11: Frequency-phase velocity image of the Sciri Tower in the SE direction (Fs=200 Hz). In order to gain a better understanding of the dispersion image previously shown in Fig. 11, the equivalent384 Timoshenko beam model derived by Ebrahimian and Todorovska [28] is adopted herein. Assuming a building385 with elastic Young’s modulus E, shear modulus G, radius of gyration rg, shear correction factor ks, and mass386 density ρ, those authors demonstrated that waves propagate according to two different propagation modes with387 phase velocities:388 16 cph 1=cS√2 1 ks +R!+s 1 ks−R!2 +4R Ω2 −1/2 ,(11) 389 cph 2=cS√2 1 ks +R!−s 1 ks−R!2 +4R Ω2 −1/2 ,(12) where Ω = ωrg/cSand R=G/Eare non-dimensional parameters, and cL=pE/ρ and cS=pG/ρ are the390 longitudinal and shear wave velocities in the material, respectively. A closer inspection of Eqs. (11) and (12)391 reveals that cph 1is real-valued for all ω, while cph 2only becomes real when ω > ωcr, with ωcr being a cut-off392 frequency for the second wave propagation mode or critical frequency given by [28]:393 ωcr =cSpks/rg.(13) When ω<ωcr,cph 2is complex-valued, and the second propagation mode only defines exponentially attenuated394 non-propagating waves or evanescent waves. Additionally, an asymptotic analysis of Eqs. (11) and (12) shows395 that when R≤1/ks, as it is typically the case, lim ω→∞ cph 1=cS√ksand lim ω→∞ cph 2=cS/√R. Therefore, the theoretical396 dispersion curves of the two propagation modes can be obtained by considering a critical frequency value of397 fcr =ωcr/2π=17 Hz, and the limits lim ω→∞ cph 1=500 m/s and lim ω→∞ cph 2=510 m/s, according to the image dispersion398 shown in Fig. 11. Moreover, a shear correction factor ks=0.43 has been also assumed, corresponding to a tower399 with thin-walled hollow square cross-section according to Cowper’s formulae (with Poisson’s ratio ν=0.25)400 [47]. These assumptions completely define the dispersion curves from Eqs. (11) and (12), and the results have401 been included in Fig. 11. It is interesting to note that, effectively, the curve corresponding to the second wave402 propagation mode cph 2explains the second trend of maximum V(ω, cph) values. Likewise, the coexistence of403 these two wave propagation modes above the critical frequency fcr originates complex interference patters, what404 explains the complex wavefronts previously reported in Figs. (10) (d) and (e). Finally, it should be noted that405 some differences can be found between the experimental and theoretical dispersion at high frequencies. While406 the analytical solution for cph 2reports monotonically decreasing values, the experimental dispersion image yields407 peaks with increasing phase velocities for increasing frequencies. This fact may evidence modelling limitations408 of the TB model developed by Ebrahimian and Todorovska [28] for this case study, and the contribution of the409 building aggregate may require more sophisticated modelling approaches for explaining the dispersion behaviour410 of the Sciri Tower for high frequency bands.411 5. Conclusions412 This paper has proposed the coupled application of automated OMA and ANDI for the full structural system413 identification of historic structures. The Sciri Tower in Perugia (Italy) has been presented as a validation case414 study to evaluate the effectiveness of the proposed methodology for identifying environmental effects. To do so, a415 vibration-based monitoring system consisting of twelve accelerometers deployed at different heights of the tower416 have been installed, and ambient vibrations have been recorded since February 13th until March 10th 2019. The417 presented results report the identification and tracking of the modal properties and wave propagation properties of418 the Sciri Tower throughout the monitoring time. In order to assess the robustness of the identification of ambient419 noise waves, three different sampling frequencies have been used in the monitoring, including Fs=200 Hz,420 1000 Hz, and 5000 Hz. The results have highlighted the importance of high sampling frequencies for detecting421 the influence of environmental temperature and, as a result, for SHM systems for early damage detection. In422 addition, ANDI has proved to represent a complementary technique to OMA, and its capability for providing423 local information on the intrinsic stiffness properties of the Sciri Tower has been shown. Finally, the reported424 results have shed some light into the dispersion effects on the wave propagation properties of the tower.425 The main key findings of this research can be summarised as follows:426 •High sampling frequencies have been shown crucial for detecting environmental effects on wave velocities.427 Specifically, a positive correlation between wave velocities and environmental temperature has been found428 by using sampling frequencies of 1000 Hz and 5000 Hz. This behaviour has been ascribed to temperature-429 induced closure of cracks and discontinuities, and is consistent with the observed positive correlation be-430 tween resonant frequencies and environmental temperature of seven vibration modes identified and tracked431 in the frequency interval 0-12 Hz.432 17 •Wave velocities obtained by peak-picking analysis of IRFs have proved to provide valuable information433 about the stiffness distribution of the Sciri Tower. In particular, increasing wave velocities have been found434 in height, and local analyses have allowed us to identify the constraints imposed by the adjoining building435 in two orthogonal directions.436 •The presented results have shown that, in the SE direction (direction of maximum constraint by the adjoining437 building), the bottom part of the tower is highly sensitive to temperature fluctuations. Conversely, motions438 in the NE direction (direction with one of the fac¸ades of the tower unconstrained by the building aggregate)439 are minimally affected by temperature. This behaviour is conceivably associated to the circumstance that440 temperature-induced deformation is more constrained in the lower part of the tower.441 •Peak-picking analyses of band-pass filtered IRFs have evidenced the dispersion-type behaviour of the Sciri442 tower. Additionally, dispersion imaging techniques have been applied and compared to theoretical results443 reported by an equivalent Timoshenko beam model. The results have evidenced the presence of two different444 wave propagation modes above a critical frequency of fcr ≈17 Hz. Therefore, in application to masonry445 towers, it is recommended to filter the IRFs obtained by ANDI below fcr to avoid complex interference446 patterns between two propagating modes, with fcr being possibly estimated as in Eq. (13).447 Acknowledgement448 This work was supported by the Italian Ministry of Education, University and Research (MIUR) through449 the funded project of national interest “DETECT-AGING - Degradation Effects on sTructural safEty of Cultural450 heriTAGe constructions through simulation and health monitorING” (Protocol No. 201747Y73L).451 References452 References453 [1] C. Gentile, G. Bernardini, Output-only modal identification of a reinforced concrete bridge from radar-based454 measurements, NDT & E International 41 (2008) 544–553.455 [2] W. Fan, P. Qiao, Vibration-based damage identification methods: a review and comparative study, Structural456 Health Monitoring 10 (2011) 83–111.457 [3] E. Reynders, System identification methods for (operational) modal analysis: review and comparison,458 Archives of Computational Methods in Engineering 19 (2012) 51–124.459 [4] E. P. Carden, P. Fanning, Vibration based condition monitoring: a review, Structural health monitoring 3460 (2004) 355–377.461 [5] S. K. Au, F. L. Zhang, Y. C. Ni, Bayesian operational modal analysis: theory, computation, practice, Com-462 puters & Structures 126 (2013) 3–14.463 [6] M. G. Masciotta, L. F. Ramos, P. B. Lourenc¸o, The importance of structural monitoring as a diagnosis and464 control tool in the restoration process of heritage structures: a case study in Portugal, Journal of Cultural465 Heritage 27 (2017) 36–47.466 [7] X. Kong, J. Li, W. Collins, C. Bennett, S. Laflamme, H. Jo, Sensing distortion-induced fatigue cracks in467 steel bridges with capacitive skin sensor arrays, Smart Materials and Structures 27 (2018) 115008.468 [8] R. M. Azzara, G. De Roeck, M. Girardi, C. Padovani, D. Pellegrini, E. Reynders, The influence of en-469 vironmental parameters on the dynamic behaviour of the San Frediano bell tower in Lucca, Engineering470 Structures 156 (2018) 175–187.471 [9] E. Mesquita, A. Arˆ ede, N. Pinto, P. Antunes, H. Varum, Long-term monitoring of a damaged historic472 structure using a wireless sensor network, Engineering Structures 161 (2018) 108–117.473 [10] P. Pach´ on, R. Castro, E. Garc´ ıa-Mac´ ıas, V. Compan, E. Puertas, E. Torroja’s bridge: Tailored experimental474 setup for SHM of a historical bridge with a reduced number of sensors, Engineering Structures 162 (2018)475 11–21.476 [11] S. Ivorra, D. Foti, V. Gallo, V. Vacca, D. Bru, Bell’s dynamic interaction on a reinforced concrete bell tower,477 Engineering Structures 183 (2019) 965–975.478 18 [12] C. Gentile, C. Poggi, A. Ruccolo, M. Vasic, Vibration-Based Assessment of the Tensile Force in the Tie-Rods479 of the Milan Cathedral, International Journal of Architectural Heritage (2019) 1–14.480 [13] W. Soo Lon Wah, Y. T. Chen, G. W. Roberts, A. Elamin, Separating damage from environmental effects481 affecting civil structures for near real-time damage detection, Structural Health Monitoring 17 (2018) 850–482 868.483 [14] F. Ubertini, N. Cavalagli, A. Kita, G. Comanducci, Assessment of a monumental masonry bell-tower after484 2016 Central Italy seismic sequence by long-term SHM, Bulletin of Earthquake Engineering 16 (2018)485 775–801.486 [15] E. S¸afak, Wave-propagation formulation of seismic response of multistory buildings, Journal of Structural487 Engineering 125 (1999) 426–437.488 [16] M. I. Todorovska, S. S. Ivanovi´ c, M. D. Trifunac, Wave propagation in a seven-story reinforced concrete489 building: I. Theoretical models, Soil Dynamics and Earthquake Engineering 21 (2001) 211–223.490 [17] R. Snieder, E. S¸afak, Extracting the building response using seismic interferometry: Theory and application491 to the Millikan Library in Pasadena, California, Bulletin of the Seismological Society of America 96 (2006)492 586–598.493 [18] M. D. Trifunac, S. S. Ivanovi´ c, M. I. Todorovska, Wave propagation in a seven-story reinforced concrete494 building: III. Damage detection via changes in wavenumbers, Soil Dynamics and Earthquake Engineering495 23 (2003) 65–75.496 [19] M. D. Kohler, T. H. Heaton, S. C. Bradford, Propagating waves in the steel, moment-frame factor building497 recorded during earthquakes, Bulletin of the Seismological Society of America 97 (2007) 1334–1345.498 [20] M. I. Todorovska, M. T. Rahmani, System identification of buildings by wave travel time analysis and499 layered shear beam models–Spatial resolution and accuracy, Structural Control and Health Monitoring 20500 (2013) 686–702.501 [21] S. S. Ivanovic, M. D. Trifunac, M. D. Todorovska, On identification of damage in structures via wave travel502 times, in: Strong Motion Instrumentation for Civil Engineering Structures, Springer, 2001, pp. 447–467.503 [22] M. I. Todorovska, M. D. Trifunac, Earthquake damage detection in the Imperial County Services Building504 III: analysis of wave travel times via impulse response functions, Soil Dynamics and Earthquake Engineering505 28 (2008) 387–404.506 [23] M. Rahmani, M. Ebrahimian, M. I. Todorovska, Time-wave velocity analysis for early earthquake dam-507 age detection in buildings: Application to a damaged full-scale RC building, Earthquake Engineering &508 Structural Dynamics 44 (2015) 619–636.509 [24] M. Ebrahimian, M. Rahmani, M. I. Todorovska, Nonparametric estimation of wave dispersion in high-rise510 buildings by seismic interferometry, Earthquake Engineering & Structural Dynamics 43 (2014) 2361–2375.511 [25] M. I. Todorovska, Seismic interferometry of a soil-structure interaction model with coupled horizontal and512 rocking response, Bulletin of the Seismological Society of America 99 (2009) 611–625.513 [26] M. I. Todorovska, Soil-structure system identification of Millikan Library North-South response during four514 earthquakes (1970-2002): What caused the observed wandering of the system frequencies?, Bulletin of the515 Seismological Society of America 99 (2009) 626–635.516 [27] M. Rahmani, M. Ebrahimian, M. I. Todorovska, Wave dispersion in high-rise buildings due to soil–structure517 interaction, Earthquake Engineering & Structural Dynamics 44 (2015) 317–323.518 [28] M. Ebrahimian, M. I. Todorovska, Wave propagation in a Timoshenko beam building model, Journal of519 Engineering Mechanics 140 (2013) 04014018.520 [29] M. I. Todorovska, M. D. Trifunac, Impulse response analysis of the Van Nuys 7-storey hotel during 11 earth-521 quakes and earthquake damage detection, Structural Control and Health Monitoring: The Official Journal of522 the International Association for Structural Control and Monitoring and of the European Association for the523 Control of Structures 15 (2008) 90–116.524 19 [30] M. Rahmani, M. I. Todorovska, 1D system identification of buildings during earthquakes by seismic inter-525 ferometry with waveform inversion of impulse responses–method and application to Millikan library, Soil526 Dynamics and Earthquake Engineering 47 (2013) 157–174.527 [31] M. Ebrahimian, M. I. Todorovska, Structural system identification of buildings by a wave method based on528 a nonuniform Timoshenko beam model, Journal of Engineering Mechanics 141 (2015) 04015022.529 [32] E. Garc´ ıa-Mac´ ıas, F. Ubertini, Seismic interferometry for earthquake-induced damage identification in his-530 toric masonry towers, Mechanical Systems and Signal Processing 132 (2019) 380–404.531 [33] G. A. Prieto, J. F. Lawrence, A. I. Chung, M. D. Kohler, Impulse response of civil structures from ambient532 noise analysis, Bulletin of the Seismological Society of America 100 (2010) 2322–2328.533 [34] N. Nakata, R. Snieder, Monitoring a building using deconvolution interferometry. II: Ambient-vibration534 analysis, Bulletin of the Seismological Society of America 104 (2013) 204–213.535 [35] D. Bindi, B. Petrovic, S. Karapetrou, M. Manakou, T. Boxberger, D. Raptakis, K. D. Pitilakis, S. Paro-536 lai, Seismic response of an 8-story RC-building from ambient vibration analysis, Bulletin of Earthquake537 Engineering 13 (2015) 2095–2120.538 [36] G. Lacanna, M. Ripepe, M. Coli, R. Genco, E. Marchetti, Full structural dynamic response from ambient539 vibration of Giotto’s bell tower in Firenze (Italy), using modal analysis and seismic interferometry, NDT &540 E International 102 (2019) 9–15.541 [37] E. Garc´ ıa-Mac´ ıas, A. Kita, F. Ubertini, Synergistic application of operational modal analysis and ambient542 noise deconvolution interferometry for structural and damage identification in historic masonry structures:543 three case studies of Italian architectural heritage, Structural Health Monitoring (2019).544 [38] F. Magalh˜ aes, ´ A. Cunha, Explaining operational modal analysis with data from an arch bridge, Mechanical545 Systems and Signal Processing 25 (2011) 1431–1450.546 [39] F. Ubertini, C. Gentile, A. L. Materazzi, Automated modal identification in operational conditions and its547 application to bridges, Engineering Structures 46 (2013) 264–278.548 [40] M. El-Kafafy, C. Devriendt, G. De Sitter, T. De Troyer, P. Guillaume, Damping estimation of offshore wind549 turbines using state-of-the art operational modal analysis techniques, in: International conference on Noise550 and Vibration Engineering, Leuven, Belgium.551 [41] M. El-Kafafy, P. Guillaume, B. Peeters, F. Marra, G. Coppotelli, Advanced frequency-domain modal analysis552 for dealing with measurement noise and parameter uncertainty, in: Topics in Modal Analysis I, Volume 5,553 Springer, 2012, pp. 179–199.554 [42] F. Ubertini, G. Comanducci, N. Cavalagli, A. L. Pisello, A. L. Materazzi, F. Cotana, Environmental effects on555 natural frequencies of the San Pietro bell tower in Perugia, Italy, and their removal for structural performance556 assessment, Mechanical Systems and Signal Processing 82 (2017) 307–322.557 [43] R. Snieder, M. Miyazawa, E. Slob, I. Vasconcelos, K. Wapenaar, A comparison of strategies for seismic558 interferometry, Surveys in Geophysics 30 (2009) 503–523.559 [44] M. Hubert, M. Debruyne, P. J. Rousseeuw, Minimum covariance determinant and extensions, Wiley Inter-560 disciplinary Reviews: Computational Statistics 10 (2018) e1421.561 [45] C. B. Park, R. D. Miller, J. Xia, Imaging dispersion curves of surface waves on multi-channel record, in: SEG562 Technical Program Expanded Abstracts 1998, Society of Exploration Geophysicists, 1998, pp. 1377–1380.563 [46] C. Cornou, M. Ohrnberger, D. M. Boore, K. Kudo, P. Y. Bard, E. Chaljub, F. Cotton, P. Gueguen, Derivation564 of structural models from ambient vibration array recordings: results from an international blind test, ESG565 (2006).566 [47] G. R. Cowper, The shear coefficient in Timoshenko’s beam theory, Journal of Applied Mechanics 33 (1966)567 335–340.568 20