Effect of White Light-Emitting Diode Illuminants Recommended by the CIE on Colors of Dental Ceramic Materials

Ruiz López, Javier,Melgosa Latorre, Manuel,Ghinea, Razvan Ionut,Tejada Casado, María de la Nativida,Pérez Gómez, María Del Mar

Abstract

Junta de Andalucia A-FQM-30-UGR20 P20-00200

Full text

Citation: Ruiz-López, J.; Melgosa, M.; Ghinea, R.; Tejada-Casado, M.; Pop-Ciutrila, I.-S.; Pérez, M.M. Effect of White Light-Emitting Diode Illuminants Recommended by the CIE on Colors of Dental Ceramic Materials. Appl. Sci. 2023,13, 1518. https://doi.org/10.3390/ app13031518 Academic Editor: Vittorio Checchi Received: 12 December 2022 Revised: 17 January 2023 Accepted: 19 January 2023 Published: 24 January 2023 Copyright: © 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/). applied sciences Article Effect of White Light-Emitting Diode Illuminants Recommended by the CIE on Colors of Dental Ceramic Materials Javier Ruiz-López 1,2 , Manuel Melgosa 1, Razvan Ghinea 1,2,3 , Maria Tejada-Casado 1,2, Ioana-Sofia Pop-Ciutrila 4and María M. Pérez 1,2,* 1Department of Optics, Faculty of Science, Campus Fuentenueva, Edificio Mecenas, s/n., University of Granada, 18071 Granada, Spain 2Instituto de Investigación Biosanitaria ibs.GRANADA, 18011 Granada, Spain 3Department of Physics, Faculty of Sciences, University of Craiova, 13 AI Cuza Street, 200585 Craiova, Romania 4Department of Conservative Dentistry and Endodontics, Faculty of Dental Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, 33 Motilor Street, 400001 Cluj-Napoca, Romania *Correspondence: [email protected]; Tel.: +34-958246164 Abstract: The aim of this study was to evaluate color inconstancy of dental ceramics under the white light-emitting diode illuminants recently proposed by the CIE. From spectral reflectance factors of 18 dental ceramics (VST, NSP, and IEC; shades A1, A2, A3, A3.5, B2, and C2), the corresponding colors under illuminant D65 and CIE 1931 Standard Colorimetric Observer were computed for all samples, using the chromatic adaptation transform CIECAT16. CIEDE2000 color differences between dental ceramics illuminated by CIE D65 standard illuminant and different white LED illuminants were calculated. Perceptibility and acceptability thresholds (PT 00 and AP 00 ) in dental ceramics were used to analyze color changes. Color gamut size was within the same range for all illuminants and for all ceramics, since MCDM computed values were 4.1–4.4 for VST, 4.0–4.2 for NSP, and 4.3–4.6 for IEC . For all ceramics and shades, the color inconstancies were higher than 50:50% PT 00 and, in general, lower than 50:50% AT 00 . The effect of CIE-proposed LED illuminants on dental ceramic is perceptible and slightly lower than on natural teeth. Dental clinicians should consider these lighting effects on the visual appearance of dental ceramics. Keywords: dental ceramics; white light-emitting diode; color; CIEDE2000 1. Introduction The color appearance of teeth needs to be matched and reproduced by restorative dental materials to achieve acceptable aesthetic conditions. The ISO/TR 2864:2016 Dentistry—Guidance on Colour Measurement [ 1 ] describes visual and instrumental methods for assessment of subjects related to color shade and interconvertibility of monochromatic and polychromatic dental tissues and/or dental materials. Bearing this in mind, the characteristic of the light source (or illuminant) used to illuminate a given sample for a color measurement must be specified. The official illuminants used in colorimetry have been published by the Commission Internationale de l’Éclairage (CIE) (see Abbreviations list in supplementary materials) [ 2 ]. This published set of illuminants includes spectral data approaching daylights and various incandescent, fluorescent, discharge, and LED lamps. Among all the descriptors of an illuminant, in particular, the spectral power distribution (SPD) and correlated color temperature (CCT) [ 2 ] are of utter importance for the experimental setup when evaluating color appearance of teeth and dental materials. A light source which represents noon daylight (CCT of 6500K) with a color rendering index (CRI) of 90 or greater is recommended when visual color assessments are made in dentistry [ 1 ]. In this Appl. Sci. 2023,13, 1518. https://doi.org/10.3390/app13031518 https://www.mdpi.com/journal/applsci Appl. Sci. 2023,13, 1518 2 of 14 context, it is important to point out that the color difference exhibited by a specimen across different viewing conditions is known as color inconstancy [3]. The CIE has been responsible for introducing the main color systems, illumination/detection geometries and color difference ( ∆ E), and color appearance concepts used in color science [ 4 ]. When considering CIELAB color space, the CIELAB color difference ∆E∗ ab has been the standard parameter employed by many users to measure total color difference. However, the CIE [ 2 ] recommend the use of the CIEDE2000 color difference formula ( ∆E00 ) [ 5 ] because it provides a better fit than the CIELAB formula for visual color differences managed in many different industrial applications, including dentistry [6–9]. In dentistry, visual judgments are the most frequently used method for evaluating color. Thus, adequate knowledge of the limits of the perception of colors in dentistry is crucial for understanding color differences in clinical dentistry [ 10 ]. Just perceptible refers to the lowest color difference that can be detected by an average human observer with normal color vision. A color difference noticeable by 50% of the observers corresponds to a 50:50% perceptibility threshold (PT). Similarly, the difference in color that is considered as acceptable for 50% of observers corresponds to a 50:50% acceptability threshold (AT) [ 11 ]. The visual color thresholds are of extreme importance in interpreting color differences in clinical dentistry and dental research [ 12 , 13 ]. Several studies have established the value of color discrimination thresholds in dentistry [ 13 ] and, in particular, Ghinea et al. [14] determined the values of CIEDE2000 color difference thresholds in dental ceramics ( PT00 = 1.25 and AT00 = 2.23). General lighting is currently undergoing a revolutionary shift towards solid state devices, in particular light emitting diode (LED)-based technologies, as a replacement for classic fluorescent lamps. LEDs save energy and provide the same or better quality of illumination and visual comfort than classic fluorescent lamps. Researchers [ 15 ] investigated the perceived quality of LED sources in psychophysical experiments, considering color difference assessment and color appearance estimation. The results show that LEDs outperformed conventional fluorescent lamp-based simulators for the CIE illuminant D50. Furthermore, colorimetric measures revealed that LED simulators can achieve the desired quality according to the relevant ISO and CIE standards [ 16 ]. Another study [ 17 ] showed that an optimized LED spectrum illumination based on human perception of color differences significantly improved the visibility of tissue texture compared to illuminants such as CIE D65. In order to provide an approximate representation of the available range of white LED sources, the CIE proposed a series of 9 specific LED illuminants [ 2 ]: LEDS B1 to B5 illuminants (typical phosphor-converted blue LEDs with different CCTs); LED BH1 illuminant (of mixing phosphor-converted blue and red LEDs); LED RGB1 illuminant (mixture of red, green, and blue LEDs); and LEDs V1 and V2 (traditional phosphor-converted violet LEDs with modified CCTs) [ 2 ]. Currently, B1 to B5 LEDs are the most frequently used. The SPDs of the 9 LED illuminants proposed were obtained from experimental measurements of a total of 1298 commercial white LED conventional sources [18,19]. The effect that these nine CIE white illuminants have on visual appearance has been evaluated for cosmetic applications [ 20 ] and museum lighting [ 21 ]. In dentistry, a recent study [ 22 ] evaluated the color inconstancy of natural teeth measured under white lightemitting diode illuminants. The authors concluded that the CIE-proposed LED illuminants produced perceptible and no acceptable color and whiteness differences on the evaluated teeth when compared with CIE standard illuminants D65 and A. Nevertheless, to the best of our knowledge, there are no studies that have evaluated color inconstancy for dental ceramics when illuminated with the newly proposed CIE LED illuminants relative to their color as illuminated with the CIE-recommended standard illuminant. Therefore, the main purpose of this study was to evaluate the color changes of dental ceramics based on CIE LED illuminants relative to the CIE D65 standard illuminant recommended for dentistry, considering color difference thresholds in dental ceramics. Appl. Sci. 2023,13, 1518 3 of 14 2. Materials and Methods 2.1. Samples and Illuminants The spectral reflectance factors of 3 ceramic restorative materials of different classifications (Table 1) were measured using a non-contact measuring system. The device was composed of a spectroradiometer (PR 670-Photo Research, Chatsworth, CA, USA) and a double-fiber optic light cable (Oriol Research, Newport Corporation, CA, USA) coupled to a Xe-Arc light source (Oriol Research, Newport Corporation, CA, USA). Measurements ( 380–780 nm in steps of 2 nm) were performed using the CIE illuminating/measuring geometry 45 ◦ :0 ◦ and a spectrally calibrated reflectance standard (SRS-3, PhotoResearch, CA, USA) in a dark room, where the specimens were placed 40 cm away from the spectroradiometer over a black 50 × 50 mm ceramic tile background (L* = 3.1, a* = 0.7 and b* = 2.4) (Ceram, Stafford, UK) (Figure 1). For each specimen, 3 samples (2.0 mm-thick) were prepared and 3 repeated measurements without replacement were performed for each sample, and the results were averaged into a single value. Figure 2shows the mean measured spectral reflectance factors of the 18 ceramic specimens evaluated in this study. An experienced investigator performed all spectral reflectance factor measurements of dental ceramics. Table 1. Characteristics and information on the ceramic materials included in this study. All resinbased composite data were provided by manufacturers. Material Manufacturer Classification Shades Vita Suprinity Translucent (VST) Vita Zahnfabrik (Bad Säckingen, Germany) ZrO2 lithium silicate glass ceramic A1 A2 A3 A3.5 B2 C2 Noritake Super Porcelain EX-3 (NSP) Kuraray Noritake Dental (Tokyo, Japan) Conventional feldspathic ceramic IPS-Empress CAD Low Translucency (IEC) Ivoclar Vivadent (Schaan, Liechtenstein) Leucite-reinforced glass-ceramic Appl. Sci. 2023, 13, x FOR PEER REVIEW 3 of 14 2. Materials and Methods 2.1. Samples and Illuminants The spectral reflectance factors of 3 ceramic restorative materials of different classifications (Table 1) were measured using a non-contact measuring system. The device was composed of a spectroradiometer (PR 670-Photo Research, Chatsworth, CA, USA) and a double-fiber optic light cable (Oriol Research, Newport Corporation, CA, USA) coupled to a Xe-Arc light source (Oriol Research, Newport Corporation, CA, USA). Measurements (380–780 nm in steps of 2 nm) were performed using the CIE illuminating/measuring geometry 45°:0° and a spectrally calibrated reflectance standard (SRS-3, PhotoResearch, CA, USA) in a dark room, where the specimens were placed 40 cm away from the spectroradiometer over a black 50 × 50 mm ceramic tile background (L* = 3.1, a* = 0.7 and b* = 2.4) (Ceram, Stafford, UK) (Figure 1). For each specimen, 3 samples (2.0 mm-thick) were prepared and 3 repeated measurements without replacement were performed for each sample, and the results were averaged into a single value. Figure 2 shows the mean measured spectral reflectance factors of the 18 ceramic specimens evaluated in this study. An experienced investigator performed all spectral reflectance factor measurements of dental ceramics. Figure 1. Experimental device configuration used for color measurements. Figure 2. Average spectral reflectance factors on black background of the 18 ceramic materials studied in this study. Figure 1. Experimental device configuration used for color measurements. Measured spectral reflectance factors (Figure 2) were converted into CIE tristimulus values (X i , Y i , Z i (i = 1 . . . 18)) using the CIE 1931 2 ◦ Standard Colorimetric Observer and D65 standard illuminant as well as the 9 CIE white LED illuminants (Figure 3). According to a previous study [22], corresponding colors were computed using a chromatic adaptation transform (CAT) [ 3 ], that is, different tristimulus values are obtained from colors with Appl. Sci. 2023,13, 1518 4 of 14 the same visual appearance as the initial ones. This was undertaken in order to make meaningful comparisons, since a common viewing condition was achieved. Then, from these corresponding colors, a conventional color difference formula could be used to obtain the ‘color inconstancy’ index [3]. Appl. Sci. 2023, 13, x FOR PEER REVIEW 3 of 14 2. Materials and Methods 2.1. Samples and Illuminants The spectral reflectance factors of 3 ceramic restorative materials of different classifications (Table 1) were measured using a non-contact measuring system. The device was composed of a spectroradiometer (PR 670-Photo Research, Chatsworth, CA, USA) and a double-fiber optic light cable (Oriol Research, Newport Corporation, CA, USA) coupled to a Xe-Arc light source (Oriol Research, Newport Corporation, CA, USA). Measurements (380–780 nm in steps of 2 nm) were performed using the CIE illuminating/measuring geometry 45°:0° and a spectrally calibrated reflectance standard (SRS-3, PhotoResearch, CA, USA) in a dark room, where the specimens were placed 40 cm away from the spectroradiometer over a black 50 × 50 mm ceramic tile background (L* = 3.1, a* = 0.7 and b* = 2.4) (Ceram, Stafford, UK) (Figure 1). For each specimen, 3 samples (2.0 mm-thick) were prepared and 3 repeated measurements without replacement were performed for each sample, and the results were averaged into a single value. Figure 2 shows the mean measured spectral reflectance factors of the 18 ceramic specimens evaluated in this study. An experienced investigator performed all spectral reflectance factor measurements of dental ceramics. Figure 1. Experimental device configuration used for color measurements. Figure 2. Average spectral reflectance factors on black background of the 18 ceramic materials studied in this study. Figure 2. Average spectral reflectance factors on black background of the 18 ceramic materials studied in this study. Appl. Sci. 2023, 13, x FOR PEER REVIEW 4 of 14 Table 1. Characteristics and information on the ceramic materials included in this study. All resinbased composite data were provided by manufacturers. Material Manufacturer Classification Shades Vita Suprinity Translucent (VST) Vita Zahnfabrik (Bad Säckingen, Germany) ZrO2 lithium silicate glass ceramic A1 A2 A3 A3.5 B2 C2 Noritake Super Porcelain EX-3 (NSP) Kuraray Noritake Dental (Tokyo, Japan) Conventional feldspathic ceramic IPS-Empress CAD Low Translucency (IEC) Ivoclar Vivadent (Schaan, Liechtenstein) Leucite-reinforced glassceramic Measured spectral reflectance factors (Figure 2) were converted into CIE tristimulus values (Xi, Yi, Zi (i = 1…18)) using the CIE 1931 2° Standard Colorimetric Observer and D65 standard illuminant as well as the 9 CIE white LED illuminants (Figure 3). According to a previous study [22], corresponding colors were computed using a chromatic adaptation transform (CAT) [3], that is, different tristimulus values are obtained from colors with the same visual appearance as the initial ones. This was undertaken in order to make meaningful comparisons, since a common viewing condition was achieved. Then, from these corresponding colors, a conventional color difference formula could be used to obtain the ‘color inconstancy’ index [3]. Figure 3. Normalized (Y = 100) spectral power distributions of the 9 white CIE LED illuminants and CIE D65 illuminant [2]. The CAT known as CIECAT16 [23–25] was used to calculate the corresponding colors for the CIE 1931 Standard Colorimetric Observer as illuminated with D65 standard illuminant. This was achieved using the CIE tristimulus values (Xi, Yi, Zi) of the 18 dental ceramics calculated using D65 standard illuminant and the 9 CIE LEDs illuminants (in all cases using the CIE 1931 2° Standard Colorimetric Observer), assuming an adaptation luminance LA = 64 cd/m2 (equal to a photopic illuminance of 1000 l×), a degree of adaptation Figure 3. Normalized (Y = 100) spectral power distributions of the 9 white CIE LED illuminants and CIE D65 illuminant [2]. The CAT known as CIECAT16 [ 23 – 25 ] was used to calculate the corresponding colors for the CIE 1931 Standard Colorimetric Observer as illuminated with D65 standard illuminant. This was achieved using the CIE tristimulus values (X i , Y i , Z i ) of the 18 dental Appl. Sci. 2023,13, 1518 5 of 14 ceramics calculated using D65 standard illuminant and the 9 CIE LEDs illuminants (in all cases using the CIE 1931 2 ◦ Standard Colorimetric Observer), assuming an adaptation luminance L A = 64 cd/m 2 (equal to a photopic illuminance of 1000 lx), a degree of adaptation D= 1 , and an average surround (F= 1). Since the corresponding colors were computed under the aforementioned conditions, an adequate comparison of the CIE L*, a*, b* chromaticity coordinates of each sample computed under different illuminants was possible, since a common reference viewing condition was achieved while maintaining the different visual color appearances of all dental ceramics studied under each illuminant. 2.2. Data Processing The CIELAB color gamut of the dental ceramics studied can be described by using the average values of the CIELAB chromaticity coordinates L∗,a∗,b∗ of all samples with their standard deviations (SD) using the range of each CIELAB chromaticity coordinates or by using the mean color difference from the mean (MCDM) [ 26 ]. In this study, the MCDM was used: MCDM = ∑N i=1hL∗ i−L∗−a∗ i−a∗−b∗ i−b∗i1/2 N CIEDE2000 ( ∆E00 ) color-difference formula [ 27 ] was used to assess color inconstancy: ∆E00 ="∆L0 kLSL2 +∆C0 kCSC2 +∆H0 kHSH2 +RT∆C0 kCSC ∆H0 kHSH#1/2 where kLSL , kCSC , and kHSH are correction terms used for weighting the metric differences to the CIEDE2000 components. Parametric factors ( kL , kC and kH ) were set to 1 in this study (i.e., we used CIEDE2000(1:1:1)). The 50:50% perceptibility (PT) and acceptability (AT) color thresholds for dental ceramics described in previous literature [ 14 ] (PT 00 = 1.25 [95%CI 0.69–2.22] and AT00 = 2.23 [95%CI 1.55–3.00] were used to interpret the findings of the study. In addition, total color differences in CIEDE2000 units ( ∆E00 ) can also be described in terms of corresponding differences of the 3 main perceptual attributes of color: lightness, chroma, and hue ( ∆ L 00 , ∆ C 00 and ∆ H 00 , respectively) [ 28 ]. These 3 attributes can be presented in percentage and calculated as: % ∆attribute = 100 (∆attribute/∆E00)2 and therefore, from this definition, it follows that: %∆L00 +%∆C00 +%∆H00 =100 3. Results Tables 2–4show, for each shade and each illuminant, the average CIELAB coordinates for the three measured samples with their corresponding standard deviations (in brackets). The three ceramics studied showed similar color gamut sizes for all illuminants, as reflected by the narrow range of the MCDM: 4.1–4.4 for VST (Table 2), 4.0–4.2 for NSP (Table 3), and 4.3–4.6 for IEC (Table 4). Figure 4shows, as an example, the average color shifts (or color inconstancies) in terms of the relative displacements of the centers of gravity of the color gamuts with respect to the D65 illuminant, differentiating the a∗b∗ , a∗L∗ , and b∗L∗ planes for shade A1 (similar results can be found for the remaining shades). In terms of the D65 illuminant color shifts, it can be observed that (1) all LED illuminants studied produced a*b* shifts in several different directions of the CIELAB diagram; (2) in general, shifts in b* were larger than those in a*; and (3) the L* coordinate showed the lowest shifts for the nine LED illuminants, producing in all cases increases below 0.8 units. Appl. Sci. 2023,13, 1518 6 of 14 Table 2. Mean CIELAB color coordinate values and standard deviations (in parentheses) for the VST ceramic shades under D65 and nine LED illuminants (corresponding colors under D65 illuminant and CIE 1931 standard colorimetric observer). VST D65 LED B1 LED B2 LED B3 LED B4 LED B5 LED BH1 LED RGB1 LED V1 LED V2 A1 L∗73.5 (0.2) 74.1 (0.2) 74.1 (0.2) 73.8 (0.2) 73.8 (0.2) 73.6 (0.2) 74.1 (0.2) 73.8 (0.2) 74.0 (0.2) 73.7 (0.2) a∗−0.7 (0.0) 1.4 (0.0) 1.0 (0.0) −0.2 (0.0) −1.1 (0.0) −1.3 (0.0) 1.1 (0.0) 3.4 (0.1) 1.8 (0.0) 0.4 (0.0) b∗9.8 (0.2) 12.4 (0.2) 12.2 (0.2) 11.6 (0.2) 10.9 (0.2) 9.6 (0.2) 13.0 (0.2) 11.3 (0.2) 13.2 (0.2) 11.8 (0.2) A2 L∗74.8 (0.7) 75.8 (0.7) 75.7 (0.7) 75.3 (0.7) 75.2 (0.7) 74.9 (0.7) 75.7 (0.7) 75.5 (0.7) 75.7 (0.7) 75.2 (0.7) a∗0.6 (0.1) 2.6 (0.1) 2.2 (0.1) 0.7 (0.1) −0.7 (0.2) −0.9 (0.2) 2.6 (0.1) 6.6 (0.0) 3.8 (0.1) 2.2 (0.1) b∗14.9 (0.7) 17.4 (0.6) 17.4 (0.6) 17.0 (0.7) 16.3 (0.7) 14.9 (0.7) 18.3 (0.7) 15.8 (0.5) 18.0 (0.7) 16.7 (0.7) A3 L∗71.3 (0.2) 72.3 (0.2) 72.2 (0.2) 71.8 (0.2) 71.6 (0.2) 71.4 (0.2) 72.2 (0.2) 72.0 (0.2) 72.2 (0.2) 71.7 (0.2) a∗0.7 (0.2) 3.0 (0.1) 2.5 (0.1) 0.9 (0.1) −0.5 (0.1) −0.7 (0.1) 3.0 (0.2) 7.1 (0.3) 4.1 (0.2) 2.4 (0.2) b∗15.1 (0.5) 17.4 (0.5) 17.4 (0.5) 17.1 (0.5) 16.4 (0.5) 15.1 (0.5) 18.4 (0.5) 15.8 (0.4) 18.2 (0.5) 16.9 (0.5) A3.5 L∗68.0 (0.3) 69.0 (0.3) 68.8 (0.3) 68.4 (0.3) 68.2 (0.3) 68.0 (0.3) 68.9 (0.3) 68.9 (0.3) 69.0 (0.3) 68.4 (0.3) a∗2.0 (0.0) 4.3 (0.0) 3.8 (0.0) 2.1 (0.0) 0.7 (0.0) 0.4 (0.0) 4.4 (0.0) 8.7 (0.0) 5.7 (0.0) 3.8 (0.0) b∗13.4 (0.2) 15.8 (0.1) 15.7 (0.2) 15.2 (0.2) 14.5 (0.2) 13.2 (0.2) 16.7 (0.2) 14.7 (0.1) 16.6 (0.2) 15.2 (0.2) B2 L∗68.2 (0.7) 68.9 (0.7) 68.8 (0.7) 68.6 (0.7) 68.5 (0.7) 68.4 (0.7) 68.8 (0.7) 68.5 (0.7) 68.8 (0.7) 68.5 (0.7) a∗−1.1 (0.1) 1.0 (0.1) 0.6 (0.1) −0.6 (0.1) −1.5 (0.1) −1.7 (0.1) 0.7 (0.1) 3.1 (0.0) 1.3 (0.1) 0.0 (0.1) b∗11.0 (0.5) 13.1 (0.4) 13.0 (0.4) 12.6 (0.5) 11.9 (0.5) 10.7 (0.5) 13.9 (0.4) 11.8 (0.3) 14.1 (0.5) 12.8 (0.5) C2 L∗63.8 (0.2) 64.7 (0.2) 64.6 (0.2) 64.2 (0.2) 64.0 (0.2) 63.8 (0.2) 64.6 (0.2) 64.6 (0.2) 64.7 (0.2) 64.2 (0.2) a∗0.5 (0.2) 3.1 (0.2) 2.6 (0.2) 0.9 (0.2) −0.4 (0.2) −0.8 (0.2) 3.0 (0.2) 6.9 (0.3) 4.0 (0.3) 2.2 (0.2) b∗14.1 (0.1) 15.8 (0.1) 15.8 (0.1) 15.7 (0.1) 15.0 (0.1) 13.8 (0.1) 17.1 (0.1) 14.6 (0.1) 17.1 (0.1) 15.7 (0.1) Appl. Sci. 2023,13, 1518 7 of 14 Table 3. Mean CIELAB color coordinate values and standard deviations (in parentheses) for the NSP ceramic shades under D65 and nine LED illuminants (corresponding colors under D65 illuminant and CIE 1931 standard colorimetric observer). NSP D65 LED B1 LED B2 LED B3 LED B4 LED B5 LED BH1 LED RGB1 LED V1 LED V2 A1 L∗76.7 (0.6) 77.3 (0.6) 77.2 (0.6) 77.0 (0.6) 76.9 (0.6) 76.8 (0.6) 77.2 (0.6) 77.0 (0.6) 77.2 (0.6) 77.0 (0.6) a∗−1.1 (0.1) 1.1 (0.0) 0.7 (0.0) −0.7 (0.1) −1.5 (0.1) −1.7 (0.1) 0.9 (0.1) 2.7 (0.1) 1.7 (0.0) 0.1 (0.1) b∗9.9 (0.5) 12.8 (0.5) 12.7 (0.5) 12.1 (0.5) 11.4 (0.5) 10.1 (0.5) 13.4 (0.5) 11.5 (0.4) 12.7 (0.5) 11.5 (0.5) A2 L∗75.2 (0.2) 76.2 (0.1) 76.1 (0.1) 75.7 (0.1) 75.6 (0.1) 75.3 (0.2) 76.1 (0.1) 75.7 (0.1) 76.1 (0.1) 75.6 (0.1) a∗0.1 (0.0) 2.1 (0.0) 1.7 (0.0) 0.3 (0.0) −0.9 (0.0) −1.2 (0.0) 2.2 (0.0) 5.5 (0.1) 3.2 (0.0) 1.7 (0.0) b∗14.7 (0.2) 17.5 (0.2) 17.5 (0.2) 17.2 (0.2) 16.5 (0.2) 15.2 (0.2) 18.3 (0.2) 15.5 (0.2) 17.4 (0.2) 16.3 (0.2) A3 L∗72.2 (0.1) 73.5 (0.1) 73.3 (0.1) 72.9 (0.1) 72.7 (0.1) 72.4 (0.1) 73.3 (0.1) 72.9 (0.1) 73.3 (0.1) 72.7 (0.1) a∗0.6 (0.0) 2.5 (0.0) 2.1 (0.0) 0.6 (0.0) −0.8 (0.0) −1.0 (0.0) 2.7 (0.0) 6.9 (0.1) 4.0 (0.0) 2.4 (0.0) b∗18.2 (0.3) 20.7 (0.3) 20.8 (0.3) 20.7 (0.3) 20.2 (0.4) 18.9 (0.4) 21.6 (0.3) 18.2 (0.3) 20.6 (0.3) 19.6 (0.3) A3.5 L∗69.3 (0.3) 70.7 (0.3) 70.6 (0.3) 70.1 (0.3) 69.9 (0.3) 69.6 (0.3) 70.6 (0.3) 70.1 (0.3) 70.5 (0.3) 69.9 (0.3) a∗1.0 (0.1) 2.3 (0.1) 1.9 (0.1) 0.6 (0.1) −1.0 (0.1) −1.1 (0.1) 2.5 (0.1) 7.3 (0.2) 4.0 (0.1) 2.7 (0.1) b∗20.2 (0.2) 22.6 (0.2) 22.7 (0.2) 22.4 (0.2) 22.0 (0.2) 20.8 (0.2) 23.1 (0.2) 19.9 (0.2) 22.5 (0.2) 21.7 (0.2) B2 L∗74.0 (0.1) 74.9 (0.1) 74.8 (0.1) 74.5 (0.1) 74.4 (0.1) 74.2 (0.1) 74.8 (0.1) 74.4 (0.1) 74.7 (0.1) 74.3 (0.1) a∗−1.0 (0.0) 0.8 (0.0) 0.3 (0.0) −0.9 (0.0) −2.1 (0.0) −2.2 (0.0) 0.6 (0.0) 3.5 (0.1) 1.7 (0.0) 0.4 (0.0) b∗14.2 (0.3) 16.8 (0.3) 16.8 (0.3) 16.3 (0.3) 15.8 (0.3) 14.5 (0.3) 17.3 (0.3) 14.9 (0.2) 16.8 (0.3) 15.8 (0.3) C2 L∗68.1 (0.5) 69.2 (0.5) 69.1 (0.5) 68.7 (0.5) 68.6 (0.5) 68.3 (0.5) 69.1 (0.5) 68.7 (0.5) 69.0 (0.5) 68.5 (0.5) a∗0.2 (0.0) 1.8 (0.0) 1.4 (0.0) 0.1 (0.0) −1.2 (0.1) −1.3 (0.1) 1.8 (0.0) 5.5 (0.0) 3.1 (0.0) 1.7 (0.0) b∗15.8 (0.3) 18.3 (0.2) 18.3 (0.2) 17.9 (0.2) 17.4 (0.3) 16.2 (0.3) 18.8 (0.2) 16.2 (0.2) 18.2 (0.2) 17.3 (0.2) Appl. Sci. 2023,13, 1518 8 of 14 Table 4. Mean CIELAB color coordinate values and standard deviations (in parentheses) for the IEC ceramic shades under D65 and nine LED illuminants (corresponding colors under D65 illuminant and CIE 1931 standard colorimetric observer). IEC D65 LED B1 LED B2 LED B3 LED B4 LED B5 LED BH1 LED RGB1 LED V1 LED V2 A1 L∗76.4 (0.1) 77.1 (0.1) 77.1 (0.1) 76.8 (0.1) 76.8 (0.1) 76.6 (0.1) 77.1 (0.1) 76.8 (0.1) 77.0 (0.1) 76.7 (0.1) a∗−0.8 (0.0) 1.1 (0.0) 0.7 (0.0) −0.5 (0.0) −1.5 (0.0) −1.6 (0.0) 1.0 (0.0) 3.1 (0.1) 1.8 (0.0) 0.4 (0.0) b∗11.1 (0.1) 14.1 (0.1) 14.0 (0.1) 13.1 (0.1) 12.5 (0.1) 11.3 (0.1) 14.2 (0.1) 12.6 (0.1) 14.1 (0.1) 13.0 (0.1) A2 L∗72.3 (0.8) 73.4 (0.8) 73.3 (0.8) 72.9 (0.8) 72.8 (0.8) 72.5 (0.8) 73.3 (0.8) 72.9 (0.8) 73.2 (0.8) 72.7 (0.8) a∗−0.7 (0.0) 1.0 (0.0) 0.6 (0.0) −0.6 (0.0) −1.9 (0.0) −2.1 (0.0) 1.0 (0.0) 4.3 (0.1) 2.1 (0.0) 0.7 (0.0) b∗16.2 (0.3) 18.7 (0.2) 18.8 (0.2) 18.2 (0.3) 17.8 (0.3) 16.6 (0.3) 19.0 (0.2) 16.5 (0.2) 18.7 (0.2) 17.8 (0.3) A3 L∗69.1(0.4) 70.5 (0.4) 70.3 (0.4) 69.9 (0.4) 69.7 (0.4) 69.4 (0.4) 70.3 (0.4) 69.9 (0.4) 70.3 (0.4) 69.7 (0.4) a∗0.5 (0.0) 1.8 (0.0) 1.4 (0.0) 0.2 (0.0) −1.3 (0.0) −1.5 (0.0) 2.1 (0.0) 6.3 (0.1) 3.4 (0.0) 2.1 (0.0) b∗19.7 (0.3) 22.1 (0.3) 22.2 (0.3) 21.7 (0.3) 21.4 (0.4) 20.3 (0.4) 22.3 (0.3) 19.4 (0.2) 21.9 (0.3) 21.2 (0.3) A3.5 L∗67.2 (0.6) 68.7 (0.6) 68.6 (0.6) 68.0 (0.6) 67.8 (0.6) 67.5 (0.6) 68.6 (0.6) 68.0 (0.6) 68.5 (0.6) 67.8 (0.6) a∗1.0 (0.1) 2.2 (0.1) 1.8 (0.1) 0.6 (0.1) −1.1 (0.1) −1.3 (0.1) 2.6 (0.1) 7.5 (0.2) 4.0 (0.1) 2.7 (0.1) b∗22.6 (0.6) 24.7 (0.5) 24.9 (0.5) 24.6 (0.6) 24.4 (0.6) 23.2 (0.6) 25.0 (0.5) 21.6 (0.4) 24.5 (0.5) 24.0 (0.5) B2 L∗72.4 (0.4) 73.2 (0.4) 73.1 (0.4) 72.8 (0.4) 72.7 (0.4) 72.5 (0.4) 73.1 (0.4) 72.8 (0.4) 73.0 (0.4) 72.7 (0.4) a∗−1.6 (0.0) 0.4 (0.0) −0.1 (0.0) −1.4 (0.0) −2.6 (0.0) −2.7(0.0) 0.1 (0.0) 2.9 (0.1) 1.2 (0.0) −0.2 (0.0) b∗14.7 (0.4) 17.0 (0.4) 17.0 (0.4) 16.6 (0.4) 16.2 (0.4) 15.0 (0.4) 17.6 (0.4) 15.1 (0.3) 17.1 (0.4) 16.2 (0.4) C2 L∗66.3 (0.4) 67.3 (0.4) 67.2 (0.4) 66.8 (0.4) 66.7 (0.4) 66.5(0.4) 67.2 (0.4) 66.9 (0.4) 67.1 (0.4) 66.7 (0.4) a∗−0.5 (0.0) 1.2 (0.0) 0.8 (0.0) −0.5 (0.0) −1.7 (0.0) −1.9 (0.0) 1.2 (0.0) 4.6 (0.0) 2.4 (0.0) 1.0 (0.0) b∗15.8 (0.2) 18.1 (0.1) 18.1 (0.2) 17.8 (0.2) 17.4 (0.2) 16.2 (0.2) 18.6 (0.2) 16.0 (0.1) 18.1 (0.2) 17.3 (0.2) Appl. Sci. 2023,13, 1518 9 of 14 Appl. Sci. 2023, 13, x FOR PEER REVIEW 9 of 14 Figure 4. Projections of the color shifts produced by each one of the nine LED illuminants on the 𝑎∗ 𝑏∗,𝑎∗ 𝐿∗, and 𝑏∗ 𝐿∗ planes, using as common origin the coordinates under illuminant D65 for shade A1. Results for the three dental ceramics analyzed are distinguished (left: VST; center: NSP; right: IEC). Figure 5 shows total color differences (color inconstancies) between chromaticity coordinates obtained with each LED illuminant and chromaticity coordinates obtained with the D65 illuminant. Differences in lightness, chroma, and hue components of the total CIEDE2000 color difference are shown. It can be noted that in general for all illuminants, differences in hue made the greatest contribution to the total color difference with respect to illuminant D65 (Figure 5), in particular for LED B5 and LED RGB1, independently of the dental ceramic analyzed. However, in the case of LED B3 for all ceramics and LED B2 for IEC ceramic, chroma differences for all shades analyzed were mainly found. Lightness differences were almost negligible with respect to D65, due to the fact that all the illuminants tested had Y = 100 [22]. Most interesting, for all tested ceramics and shades, the CIEDE2000 color differences representative of color inconstancies were higher than 50:50% PT00 and, in general, lower than 50:50% AT00, only for LEDs B2, B3, B4, and V2. Figure 4. Projections of the color shifts produced by each one of the nine LED illuminants on the a∗b∗ , a∗L∗ , and b∗L∗ planes, using as common origin the coordinates under illuminant D65 for shade A1. Results for the three dental ceramics analyzed are distinguished (left: VST; center: NSP; right: IEC). Figure 5shows total color differences (color inconstancies) between chromaticity coordinates obtained with each LED illuminant and chromaticity coordinates obtained with the D65 illuminant. Differences in lightness, chroma, and hue components of the total CIEDE2000 color difference are shown. It can be noted that in general for all illuminants, differences in hue made the greatest contribution to the total color difference with respect to illuminant D65 (Figure 5), in particular for LED B5 and LED RGB1, independently of the dental ceramic analyzed. However, in the case of LED B3 for all ceramics and LED B2 for IEC ceramic, chroma differences for all shades analyzed were mainly found. Lightness differences were almost negligible with respect to D65, due to the fact that all the illuminants tested had Y = 100 [22]. Most interesting, for all tested ceramics and shades, the CIEDE2000 color differences representative of color inconstancies were higher than 50:50% PT 00 and, in general, lower than 50:50% AT00, only for LEDs B2, B3, B4, and V2.