Assessment of climate change's impact on energy demand in Mexican 1 buildings: Projection in single-family houses based on Representative 2 Concentration Pathways 3 4 M. Jimenez Torres1, David Bienvenido-Huertas2, O. May Tzuc3*, A Bassam4*, L. Ricalde Castellanos4, 5 M. Flota-Bañuelos4 6 7 1Postgraduate in Renewable Energy, Faculty of Engineering, Autonomous University of Yucatán, Av. Industrias No 8 Contaminantes, Merida, Yucatan, Mexico. 9 2Department of Building Construction, Higher Technical School of Building Engineering, University of Granada. Doctor 10 Severo Ochoa 18001, Spain. 11 3Faculty of Engineering, Autonomous University of Campeche, Campus V, Av Humberto Lanz, Col. Ex Hacienda Kalá, 12 C.P. 24085, San Francisco de Campeche, Campeche, México. 13 4Faculty of Engineering, Autonomous University of Yucatan, Av, Industrias No Contaminantes, Merida, Yucatan, Mexico 14 ________________________________________________________________________________________ 15 Abstract 16 In Mexico, buildings' deficient thermal performance is one of the leading causes of the 17 intensive use of energy. This research analyzes the perspective of energy demand required to 18 meet the cooling needs in the country through the Weather-based technical indexes: Cooling 19 Degree Hour (CDH) and Operation Hours (OH). The study considered the 2,440 20 municipalities that make up the 32 states of the Mexican Republic and three chronological 21 progressions throughout the 21st century (2020, 2050, and 2100). Meteorological data was 22 collected through the Meteonorm software considering climate change projections, precisely 23 two Representative Concentration Pathway scenarios (RCP 4.5 - Intermediate) and (RCP 8.5 24 - High). Based on the calculations, spatial and temporal panoramas of the behavior of air 25 conditioning hours under various target temperatures (20 °C, 23 °C, and 26 °C) were 26 established. Taking the most important type of housing in Mexico (Social Interest Housing) 27 as a case study, a database of air conditioning energy demand was performed and 28 subsequently grouped the states according to cluster similarities. The results show that more 29 than 50% of the Mexican Republic requires high air conditioning levels. The maximum CDH 30 for 2100-RCP 8.5 will be 70% higher than currently needed. Even for the year 2050-RCP8.5, 31 an increase of more than 40% of CDH was obtained. Regarding the OH, the results show an 32 increase of more than 50% concerning the current behavior of the country. Regardless of the 33 scenario, the range of operating hours with the highest operating requirements is between 11 34 am and 4 pm, peaking in the summer season. The simulations showed that some Mexican 35 regions exceed 12,000 kWh in air conditioning. An increase of 20% and 35% is expected for 36
2 the years 2050 and 2100. The simulations showed that a considerable percentage of Mexico 37 exceeds 12,000 kWh in air conditioning, while by 2050 and 2100, this consumption will 38 increase by 20% and 35%, respectively. Based on these results, the first classification of 39 groups in energy demand was generated, allowing a focus on energy efficiency strategies to 40 obtain net zero Buildings. The data obtained shows that relative humidity is a variable that 41 affects the increase in energy consumption in refrigeration and simplifies the process of 42 classifying regions with similar patterns in air conditioning. 43 44 Keywords. - Building Cooling, Weather-based technical index, Social interest house, Climate change. 45 ________________________________________________________________________________________ 46 47 *Corresponding authors 48 Email address: [email protected]dy.mx (A. Bassam);
[email protected] (O. May Tzuc) 49 50
3 Nomenclature 𝐴𝑖 Envelope area of the zone surface (i), m2 𝑐𝑝𝑎𝑖𝑟 Specific heat of the air, J/kg °C 𝑑𝑟𝑠 Distance between element r and element s ℎ𝑖 Convective heat transfer coefficient, W/m2 °C j The jth value of a specific hour in refrigeration requirements, k Referred to the kth cluster, 𝑚𝑖𝑛𝑓 Air infiltration mass flow rate, Kg/s Nr Total amount of data in measurement interval, 𝑁𝑠𝑙 Number of convective internal loads, 𝑁𝑢 Number of surfaces in the thermal zone, OH Operation Hour, Hrs 𝑄𝑖 Heat flux from source of internal load, W RH Relative humidity, % Tamb Ambient temperature, °C 𝑇𝑎𝑖𝑟𝑖𝑛𝑡 Indoor air temperature, °C TT Setpoint temperature established in the air conditioning equipment, °C 𝑇∞ Outdoor air temperature, °C 𝑇𝑠𝑖 Temperature of the envelope surface (i), °C th Hours of operation in air conditioning equipment, Hrs V Volume of the thermal zone analyzed, m3 𝑥𝑘 Position of element r in the cluster, 𝑦𝑎𝑐𝑡 Measured data of internal temperature, °C 𝑦𝑠𝑖𝑚 Simulated data of internal temperature, °C 𝑦𝑚𝑒𝑎𝑛 Mean of measured internal temperature data, °C z Total hours analyzed in the study (Month or year) Hrs Greek letters 𝜌𝑎𝑖𝑟 Air density, kg/m3
4 51 52 53 54 55 56 57 58 59 60 61 62 63 Abbreviations ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers CONAGUA National Water Commission CONAVI National Housing Commission COP22 Conference of the Parties CDD Cooling Degree Days CDH Cooling Degree Hour CV RMSE Coefficient of Variation of the Mean Squared Error ENCEVI National Survey of Energy Consumption in Private Homes FEMP Federal Energy Management Program HDD Heating Degree Days HDH Heating Degree Hour INEGI National Institute of Statistic and Geography IPCC Intergovernmental Panel on Climate Change MBE Mean Bias Error RCP Representative Concentration Pathways
5 1. Introduction 64 Currently, climate change and global warming are essential concerns for society; therefore, 65 reducing pollutants and environmental degradation is a vital part of the logbook of each 66 government [1]. Through international agreements, countries have established as one of the 67 main objectives reducing greenhouse gas emissions to keep under 1.5 °C the increment of 68 global temperature and avoid affecting future generations [2]. For this purpose, the 69 Intergovernmental Panel on Climate Change (IPCC) has determined predictive models that 70 describe pollutants and ambient temperature by the Representative Concentration Pathways 71 (RCP) for the end of the 21st century [3]. However, in recent years the energy demand to 72 meet global population needs has grown drastically, equivalent to 38 million tons of CO2 73 emitted in 2020 [4, 5]. 74 According to Ciancio et al. [6], 60% of worldwide energy demand is destinated to the 75 buildings sector, impacting 25% of global pollutant emissions. The energy requirements in 76 buildings are designated to heating processes in winter, cooling in summer, water heating, 77 and lighting. The residential subsector is of great interest due to the constant increase in 78 energy demand to cover the need for thermal comfort by using indoor artificial air 79 conditioning [7]. For this subsector, the required energy to achieve indoor satisfaction 80 conditioning is directly linked to local climatic conditions [8], so climate change and its 81 effects on environmental variables will evolve energy requirements in these buildings [9]. 82 Heating and cooling processes are equivalent to more than 50% of energy consumption in 83 the residential sector [10]; thus, following the climate change trend, this consumption is 84 expected to increase drastically for the next decades [11, 12]. It is estimated that this situation 85 of high energy consumption is further aggravated in countries with hot or tropical climates, 86 characterized by constant rates of the growing population and increased demand for air 87 conditioning for indoor cooling [13]. 88 Under this context, Mexico is one of the 55 countries that signed the treaty proposed at the 89 Conference of the Parties (COP22) for the energy transition and to reduce pollutants; 90 however, currently, the country does not have a projection of energy consumption for a sector 91 as representative as that of buildings [14]. According to the latest report by the Secretary of 92 Energy (SENER), the national energy consumption was 4,790 PJ, the buildings the third 93 largest national energy consumer with 20% [15]. The residential sector has presented an 94
6 increase in energy demand exceeding 40,000 million kWh and 20,000 million kWh in regions 95 with hot and temperate climates, respectively, allocating more than 20% of consumption for 96 air conditioning processes to obtain thermal comfort [16]. Energy consumption is mainly 97 used for space cooling; the heating process is not a sector with high demand because less 98 than 6% of homes in the country have heating equipment [17]. The great building’s energy 99 demand results from implementing materials based on concrete, brick, and block, 100 characterized by their high thermal conductivity and density. These materials do not allow 101 habitability and keep the building within the standards for thermal comfort [18, 19]. The 102 increase in buildings with materials unsuitable for the current type of climate and the trend 103 of ambient temperature as a result of climate change will affect the operating patterns in air 104 conditioning, for which it is essential to analyze the air conditioning perspective of spaces in 105 Mexico. 106 Based on those mentioned above, the air conditioning perspective can be analyzed through 107 various predictive studies classified as static and dynamic. Static studies are the first indicator 108 of the air conditioning needs of the building by contrasting the difference between the 109 ambient and internal target temperatures. Ramón et al. [20] studied the future of heating and 110 air conditioning in Belgium, considering climate change scenarios through Cooling Degree 111 Days (CDD) and Heating Degree Days (HDD). They obtained that heating will decrease by 112 30% around 2100, while air conditioning will double for the same year. Ramsebnet et al. [21] 113 analyzed the demands for CDD and HDD from the perspective of climate change towards 114 2100 (RCP 4.5) in Spain, Austria, and Northern Europe. They acquire a decrease of more 115 than 20% in HDD, while CDD will increase by around 40%, and established the existence of 116 correlation of these parameters with environmental variables. Larsen et al. [22] demonstrated 117 the trend of HDD and CDD towards 2050 and 2100 using RCP 2.6 and RCP 4.5 climate 118 change scenarios for Europe, obtaining that heating will decrease while air conditioning will 119 double compared to today. However, a more specific static approach is the Cooling Degree 120 Hour (CDH), implemented in recent studies since it is more precise when considering hourly 121 temperature variations [23]. Papakostas et al. [24] used CDH and Heating Degree Hours 122 (HDH), focusing on the air conditioning trend in Athens and Thessaloniki, Greece. They 123 obtained that a greater demand for heating is required than air conditioning. Shi et al. [25] 124 predicted that HDH will decrease due to rising ambient temperature, while CDH will increase 125
7 by 2100 in China under the RCP 4.5 climate change scenario. Salata et al. [26] established 126 maps of Italy of cooling consumption by CDH for the year 2080 under various RCP 127 scenarios, obtaining prospects for an increase in air conditioning of over 70%. The CDH and 128 CDH techniques serve as the first trend analysis of energy requirements; however, by not 129 considering the characteristics of the building, such as geometry and thermal properties, they 130 tend to underestimate the results. Under this approach, computational simulation techniques 131 analyze the buildings’ thermal behavior based on meteorological data, providing more 132 accurate predictions. Hosseini et al. [27] focused on the impact of climate change on building 133 performance through CDD and computer simulation. They covered various RCP scenarios 134 in specific decades of the 21st century, obtaining that at the end of the 21st century, 135 overheating increased by up to 140% compared to current behavior. Rey-Hernandez [28] 136 used computational models to study the energy consumption of a Zero Energy Building 137 (ZEB) in Spain, reflecting in the results the overheating of the area, increasing the demand 138 for air conditioning for the years 2050 and 2100. Bienvenido-Huertas et al. [29] studied the 139 thermal behavior of a building considering passive techniques under various RCP criteria 140 (RCP 2.6, RCP 4.5, and RCP 8.5) of climate change in France, Spain, Portugal, Argentina, 141 Brazil, and Chile. 142 Under this scenario, the review of the literature reflects that the studies focus on warm 143 climates in countries in Europe, Asia, and South America. The studies predict the trend of air 144 conditioning or heating through CDD, CDH, or energy simulation techniques; both 145 techniques are not covered to establish a comparison in a country considering all its localities. 146 Despite the number of studies analyzed in the authors' bibliographic review, no research 147 describes energy consumption in buildings throughout Mexico considering various climate 148 change scenarios throughout the 21st century. Due to its location, the national territory 149 presents diverse geographic and climatic characteristics, for which studies are required to 150 analyze these environmental variables' effects on the buildings' operational behavior. 151 Therefore, this study implements a novel approach that integrates the Weather-based 152 technical indexes (CDH and OH) and energy simulation to understand the evolution of 153 energy consumption in air conditioning in Mexico. The main objectives of the study can be 154 summarized as follows: 155
8 Establish a spatial and temporal visualization of the energy required for air 156 conditioning around 2100, aided by maps. 157 Define the energy requirements for home air conditioning, establishing three target 158 temperatures inside the building. 159 Carry out a first pre-classification of states with similar projections in consumption 160 patterns in residential buildings. 161 162 The main contribution of this work is to obtain the perspective of air conditioning in Mexico, 163 considering all its locations, through the technical indices based on Climate. Likewise, the 164 trend of energy consumption of housing in Mexico is established considering operating 165 patterns and setpoint temperatures with compiled databases, which allows grouping the states 166 by a range of energy consumption in air conditioning. This information intends to focus 167 specific studies by areas with the same operating pattern in energy demand to generate 168 focused strategies promoting energy efficiency and the search for Net Zero Energy Buildings. 169 This work is structured as follows: In section II, the description of the study area is provided 170 through the state and municipal classification of Mexico, the type of climate, as well as the 171 physical characteristics of the study dwelling. Section III describes the acquisition of the 172 climatic database, the established analyzes of the Weather-based technical indexes, the 173 energy simulation process with the target air conditioning temperatures, and the clustering 174 algorithm. Section IV analyzes the energy demand through the CDH and the OH. On the 175 other hand, the dwelling's current and future energy consumption throughout the country is 176 established, and the groups of similar patterns in artificial air conditioning processes are 177 classified. Finally, section V presents the conclusions of the study. 178 179 2. Area and case study 180 2.1. Description of the study zone 181 Mexico's territorial extension of 1.96 million km2 is located in the southern part of North 182 America [30]. Politically, the country is divided into 32 states, which in turn are subdivided 183 into 2,440 municipalities (Fig. 1). Due to the territorial area, the morphology of the land, and 184 the geographical situation, Mexico presents a great climatic diversity. The Tropic of Cancer 185 subdivides the country into various climatic zones [31]; one of the most used classifications 186
9 is the Köppen-Geiger classifying Mexico with more than 12 climates, as shown in Table 1 187 [32]. Additionally, due to climatic diversity, the ambient temperature varies between 2 °C 188 and 28.7 °C, reaching peaks of temperature above 35 °C [33, 34]. Regarding precipitation, 189 the National Water Commission (CONAGUA) establishes an annual range between 5 mm 190 and 150 mm, with July and September as the months with the highest precipitation 191 (presenting an average of 118.5 mm), while March is the driest with 10.4 mm [35]. According 192 to the latest report generated by SENER, the national energy consumption was 4,760.98 PJ, 193 with 20% allocated to the building sector in 2019 [15]. An essential factor in energy 194 consumption is the construction typology of residential buildings. In the country, there are 195 more than 35 million residential homes, of which 90% have brick, block, or cement partition 196 walls; and 70% have a concrete slab ceiling or joists with vaults [36]. These materials have 197 characteristics of heat retention and high conductivity, which do not protect similarly from 198 inclement weather in different states, particularly from temperature and radiation, which they 199 transfer during the day to the interior of the building, affecting the sensation of thermal 200 requiring air conditioning equipment [37]. 201 Likewise, more than 40% of the houses are older than 20 years, affecting the properties of 202 the envelopes. This is representative if one considers that more than 75% of the population 203 resides in urban areas, for which phenomena such as urban heat islands affect thermal 204 sensation to a greater extent. [38, 39]. 205 206 Table 1. Description of Köppen-Geiger climate classes present in Mexico 207 Köppen-Geiger climate class Climate class description Af Equatorial climate Am Monsoon climate Aw Tropical Savanna BWh Warm desert BSh Warm semi-arid BWk Cold desert BSk Cold semi-arid Csa Warm Mediterranean Cfa Warm oceanic/ Humid subtropical Cfc Cool oceanic Cwa Humid subtropical Cwb Subtropical oceanic highland
16 hour (Tamb) and the target temperature (TT), as described in Eq. 1, where z is the total hours 317 analyzed in the study. The apostrophes (+, j) refer to the jth value of a specific hour in 318 refrigeration requirements, respectively. 319 𝐶𝐷𝐻𝑠=∑(𝑇𝑎𝑚𝑏 − 𝑇𝑇)𝑗 + 𝑍 ℎ=1 (1) Another evaluation criterion is Operation Hour (OH). It is essential to clarify that the 320 behavior of the OH is not proportional to the CDH. A high CDH value results from a period 321 in which Tamb is greater than TT or is the sum of several points where there are substantial 322 differences. The OH refers to the number of hours the air conditioning equipment needs to 323 be in operation (th) to obtain the desired TT. We define this parameter as: 324 𝑂𝐻=∑𝑡ℎ; 𝑡={1, 0, 𝑇𝑇<𝑇𝑎𝑚𝑏 𝑇𝑇≥𝑇𝑎𝑚𝑏 𝑛 ℎ=1 (2) In the present study, three cases of TT were evaluated considering the 8,760 hours of the year. 325 The target temperatures were selected based on a survey that collected data on air 326 conditioning operating patterns and setpoint temperatures. Information from 28 Mexican 327 States was cataloged, allowing a complete overview of the general behavior of air 328 conditioning requirements. Fig. 4 shows the wide range of setpoint temperatures in the 329 cooling of a residential building; however, it can be clarified that the most outstanding 330 implementation temperatures are between 20 °C and 25 °C. With this information, we 331 selected the study cases to analyze energy consumption considering three TT : 20 °C, 23 °C, 332 and 26°C. The first and second correspond to the lower- and middle-point values register by 333 the survey. The last TT value was determined by the American Society of Heating, 334 Refrigerating and Air-Conditioning Engineers (ASHRAE) as the appropriate temperature for 335 thermal sensation in the predominant type of climate in Mexico [48]. With these cases, three 336 air conditioning scenarios were established, categorizing them as an extreme case of space 337 cooling (TT = 20 °C), an intermediate one (TT =23 °C), and the case of better energy 338 efficiency (TT = 26 °C), allowing the analysis of the energy trend considering the panorama 339 of climate change. In the present study, the cooling demand in the house is analyzed through 340 the CDH. The HDH (Heating Degree Hour) is not classified in the present study because less 341 than 10 % of the population uses heating to meet thermal confort [49]. 342 343
17 344 345 Figure 4. Distribution of operating temperatures according to population responses. 346 3.3. Residential energy simulation 347 In order to determine the effects of the environmental variables, an energy simulation process 348 was carried out in a residential building. The case study was executed using the EnergyPlus 349 software, which is based on the heat balance method. Through transient heat transfer 350 calculations and assumptions, the software predicts the thermal and energetic behavior [50]. 351 This method analyzes four processes: heat balance on the exterior surfaces of the envelope, 352 heat conduction through the envelope, heat balance on the interior surfaces of the envelope, 353 and heat balance of the interior air. The indoor air heat balance is the thermal zone's 354 distribution of the heat supplied to the indoor air. In a space without mechanical heating or 355 ventilation, the heat balance of the indoor air is established, as presented in Eq 3 [51]: 356 357 358 16 - 17 °C 18 - 19 °C 20 - 21 °C 22 - 23 °C 24 - 25 °C 26 - 27 °C 28 - 29 °C 0 5 10 15 20 25 30 35 Percentage or target temperatures selected by users in Mexico (%) Setpoint temperature in air conditioning (°C)
18 Energy stores in zone air = Sum of convective internal loads + Convective heat transfer from zone surfaces + Heat transfer caused by air infiltration [W] [W] [W] [W] 359 𝜌𝑎𝑖𝑟𝑉𝑐𝑝𝑎𝑖𝑟𝑑𝑇𝑎𝑖𝑟𝑖𝑛𝑡 𝑑𝑡 =∑𝑄𝑖 + ∑ℎ𝑖𝐴𝑖(𝑇𝑠𝑖 −𝑇𝑎𝑖𝑟𝑖𝑛𝑡)+ 𝑚 𝑖𝑛𝑓𝑐𝑝𝑎𝑖𝑟(𝑇∞− 𝑇𝑎𝑖𝑟𝑖𝑛𝑡) 𝑁𝑢 𝑖=1 𝑁𝑠𝑙 𝑖=1 (3) Where 𝐴𝑖= Envelope area of the zone surface (i) [m2] 𝑐𝑝𝑎𝑖𝑟= Specific heat of air [J/kg °C] ℎ𝑖= Convective heat transfer coefficient at time t [W/m2 °C] 𝑚𝑖𝑛𝑓= Air infiltration mass flow rate [kg/s] 𝑁𝑠𝑙 = Number of convective internal loads [-] 𝑁𝑢= Number of surfaces in the thermal zone [-] 𝑄𝑖= Heat flux from source of internal load [W] 𝑇𝑠𝑖 = Temperature of the envelope surface (i) [°C] 𝑇𝑎𝑖𝑟𝑖𝑛𝑡 = Indoor air temperature [°C] 𝑇∞= Outdoor air temperature [°C] V= Volume of the thermal zone [m3] 𝜌𝑎𝑖𝑟 = Air density [kg/m3] Energy Plus requires physical properties of building materials, building design, infiltration, 360 internal heat gains, and climate file. The study dwelling, dimensions, and construction set 361 were described in section 2.1; the internal load profile was established with the results issued 362 by the National Survey of Energy Consumption in Private Homes (ENCEVI) prepared by 363 the INEGI [52]. In said profile, the energy consumption of the building, the hours of 364 operation of the air conditioning equipment, and the behavior of natural ventilation were 365 configured. Fig. 5 shows the operational profile of natural ventilation and air conditioning 366 equipment throughout the year, considering the summer period (May-August) and noon- 367 summer season (January, February, March, November, and December). Fig. 5a and 5b depict 368 the behavior of open or closed windows to favor natural ventilation. For this profile, the total 369
19 number of windows in the building is considered (7 in the study dwelling) and is established 370 through the percentage of windows that remain open throughout the building. Fig. 5a was 371 implemented in the noon-summer months, in which natural ventilation is encouraged due to 372 the temperatures, while Fig. 5b is the profile used in the summer months in which air 373 conditioning is used, for which most of the windows of the building are closed. 374 On the other hand, Fig. 5c and 5d establish the operational profile of the refrigeration 375 equipment during the two periods explained above. It is imperative to point out that in the 376 case of refrigeration equipment, the period used outside of summer only considers the months 377 of March, April, September, and October. The computational model of the house 378 contemplates the previously described operational scheme. With this information, 379 simulations were carried out in the 2,440 municipalities that make up the 32 states of the 380 Mexican Republic. For this process, the EPW EN climatological files were used to obtain 381 results through Energy Plus. Fourteen thousand six hundred forty databases were established 382 according to the scenarios described in section 3.1. 383 384 385 386 387 388 389 390 391 392 393 394 395 Figure 5. Operational profile in residential building contemplated in simulation: a) Natural ventilation in non- 396 summer months; b) Natural ventilation in summer; c) Use of refrigeration systems in non-summer months; d) 397 Use in refrigeration systems in summer. 398 399 02:00 05:00 08:00 11:00 14:00 17:00 20:00 23:00 0 20 40 60 80 100 Percentage of building's open windows (%) Hour Summer season 02:00 05:00 08:00 11:00 14:00 17:00 20:00 23:00 0 20 40 60 80 100 Percentage of building's open windows (%) Hour Non-summer season 02:00 05:00 08:00 11:00 14:00 17:00 20:00 23:00 0 20 40 60 80 100 Percentage of use of air conditioning (%) Hour 02:00 05:00 08:00 11:00 14:00 17:00 20:00 23:00 0 20 40 60 80 100 Percentage of use of air conditioning (%) Hour a) b)
20 3.3.1. Validation model 400 The computational model was validated through standards issued by ASHRAE and the 401 Federal Energy Management Program (FEMP)[53]. The analysis performs a statistical 402 criterion of the simulated data concerning experimental data through the Mean Bias Error 403 (MBE; Eq. 3) and the Coefficient of Variation of the Mean Squared Error (CV RMSE; Eq. 404 4). In these equations, it is considered that 𝑚𝑖 and 𝑠𝑖 are the measured and simulated data, 405 respectively; Np is the total amount of data in the measurement interval and 𝑚 is the mean of 406 the measured data. Table 4 reflects the considerations issued by said regulations in the 407 computational validation. The internal temperature of the building was used to validate the 408 results of the computational model. Data were stored for one week at 30-minute intervals 409 through HOBO U12-012 sensors [54] in each bedroom, dining room, and kitchen. The model 410 obtained values of MBE and CV RMSE of 1.5765 and 0.0978, respectively, contrasting these 411 results with previous works (MBE = 1.96; CV RMSE = 0.74); a significant adjustment is 412 observed for which the model is adequately calibrated, validating its results[53]. 413 𝑀𝐵𝐸 (%)=∑(𝑦𝑎𝑐𝑡 −𝑦𝑠𝑖𝑚) 𝑁𝑝 𝑖−1 ∑(𝑦𝑎𝑐𝑡) 𝑁𝑝 𝑖−1 ∗100 (4) 𝐶𝑉(𝑅𝑀𝑆𝐸)(%)=√∑(𝑦𝑎𝑐𝑡 −𝑦𝑠𝑖𝑚)2 𝑁𝑝 𝑖−1 𝑁𝑟 ⁄ 𝑦𝑚𝑒𝑎𝑛 (5) 414 Table 4. Validation parameters of energy models based on international regulations. 415 Estandar Monthly criteria (%) Time criteria (%) MBE CV RMSE MBE CV RMSE ASHRAE 5 15 10 30 FEMP 5 15 10 30 416 3.4. Pattern Consumption Clustering 417 Cluster analysis is a partitioning process of observations in which similar characteristics are 418 identified between the elements of the same group, and there are no similarities among the 419 clusters. The K-means algorithm was used in this study. This method is one of the most 420 widely used due to its speed, easy implementation, and ability to process large databases [55]. 421 The main idea is the minimization of an objective function, and this is done through an 422
21 iterative process in which the weights of the groupings C are determined, and a random 423 selection of N input vectors is made. This process defines (Eq. 6), where “𝑑𝑟𝑠” is the distance 424 between element r and element s, ‘𝑥𝑘’ is the position of element r in space 425 ‘𝑥𝑘’=(𝑥𝑚2,𝑥𝑚2,…,𝑥𝑚𝑝), and ‘p’ is the spatial dimension. 426 𝑑𝑟𝑠 2=∑ (𝑥𝑟𝑗 −𝑥𝑠𝑗)2 𝑝 𝑗=1 (6) The K-means algorithm has been analyzed in various works, from the correlation of energy 427 consumption parameters and building characteristics, variables that affect the consumption 428 of buildings, and the analysis of air conditioning equipment patterns to climatic 429 reclassification. [56–58]. 430 431 4. Results and discussions 432 4.1. Comfort scenario analysis based on RCP 433 In this section, aided by maps, the behavior of CDH throughout the Mexican territory is 434 analyzed. The objective is to obtain a spatial perspective of energy demand in air conditioning 435 considering the various weather conditions produced by the RCP scenarios. According to the 436 methodology described in section 3.2, the spatial distribution of the CDH and OH cover the 437 emission scenarios RCP 4.5 and RCP 8.5. These results were calculated for each municipality 438 at the hourly level, considering that the ambient temperature is higher than the TT (20°C, 439 23°C, and 26°C). Fig. 6 presents the cumulative sum of the difference between Tamb and the 440 TT for the 2,400 Mexican municipalities throughout the year. The case with the highest 441 refrigeration requirement is for TT = 20 °C, even considering that for the year 2020, the 442 demand is higher than the refrigeration requirements for a TT = 23 °C in 2100 with RCP 4.5. 443 Results in Fig. 6 established that the CDH required by increasing the target temperature by 3 444 °C and 6 °C decreases by more than 30% and 50%, respectively. 445 446 447
22 448 Figure 6. Cooling degree hours in residential air conditioning in Mexico in 2020, 2050, and 2100 under the 449 (RCP 4.5 and RCP 8.5) scenarios. 450 The set of figures (Fig. 7 – Fig. 9) represents the increase in temperature gradient through a 451 chromatic scale; as the need for cooling increases in each municipal area, the chromatic scale 452 increases in intensity. In Fig. 7a, the distribution of CDH is observed adjusting a TT = 20 °C. 453 The country's center requires less air conditioning than the north and southeast of Mexico, 454 caused of the different climatic typologies. A radial distribution is exhibited, in which the 455 area's geography has a significant impact as the CDH gradually increases as the 456 municipalities approach the coastal zones. For the year 2050, it is observed under the two 457 RCP scenarios that the use of air conditioning increases by 70% compared to the current 458 scenario, while for the year 2100, the cooling requirements double the current demand for air 459 conditioning. This data is relevant because, in less than 80 years, it is estimated that the 460 country's energy consumption for cooling in buildings will double. From the point of view 461 of thermal comfort, this trend highlights the great dependence on air conditioning equipment 462 due to changes in the environment. Likewise, with these results, it becomes evident to analyze 463 the current constructive approach to reduce the transfer of heat from the environment to the 464 interior of the building and thereby achieve energy efficiency. In Fig. 7b, the trend of the OH 465 with a TT = 20 °C is manifested; the wide range of air conditioning requirements is notorious, 466 ranging from 2,000 hours in the center of the country to over 5,000 hours in the southeast, 467 specific cities in the north, and coastal regions. Quantifying these values, the country's center 468 during the year requires the implementation of air conditioning less than 20% of the time, 469 while the air conditioning system must be used more than 50% annually in the northern, 470
23 southeastern, and southern coastal areas. Under the future context with the two emission 471 scenarios considered, there is an increase of more than 60%, causing the cooling equipment 472 to be implemented for more than six thousand hours and eight thousand hours for the years 473 2050 and 2100, respectively. 474 Fig. 8 exposes the scenario of TT = 23 °C. A similar CDH pattern is evident in the coastal 475 areas and the southeast of the country concerning the previous case (Fig. 8a). The future 476 development of the air conditioning of spaces warns of a higher increase of 60% and 80% in 477 the years 2050 and 2100, respectively. This national cooling needs increment is derived from 478 the Tamb rise by pollutants and factors of overpopulation. Comparing these results with 479 respect TT = 20 °C results in a saving air conditioning consumption of 40 %. Under this exact 480 scenario, but analyzing the OH, Fig. 8b shows that the coastal areas and the southeast of the 481 country tend to require more than two thousand hours to use the air conditioning. In the 482 future, cooling equipment operation will be more significant than 40% compared to current 483 behavior. 484 The last CDH scenario (TT = 26 °C) is shown in Fig. 9, establishing that the areas of the 485 north, southeast, and bordering the coast are the ones with the highest air conditioning 486 requirements; regions with Tamb>26 °C throughout the year. In this scenario, there is a 65% 487 and 48% decrease in cooling needs compared to the others (TT = 20 °C, TT = 23 °C). In the 488 field of OH, Fig. 9b shows that less than a thousand hours of use of air conditioning 489 equipment are required at the national level; specifically, the decrease in operating hours 490 exceeds 40%. It is essential to point out that a superior TT has benefited from several points 491 of view. From a health perspective, raising the thermostat temperature prevents significant 492 thermal shock from being in contact with the environment. The latter is vital in regions with 493 ambient temperatures above 28 °C and high humidity (southeast and coastal areas). On the 494 other hand, increasing the thermostat’s temperature affects the user’s economy. For each 495 degree Celsius decrease in the thermostat, energy consumption increases by approximately 496 8% depending on the technology of the equipment. Finally, by decreasing the working time 497 of the cooling system, the emissions of pollutants from the gases emitted by the system are 498 reduced, as is the production of electrical energy (minimum, maximum and average values 499 of the cases analyzed are presented in the appendix). 500
501 Figure 7. Geographical distribution in Mexico along the year in 2020, 2050, 2100 (RCP 4.5 and RCP 8.5) scenarios considering TT>20°C a) Map of CDH; b) Map 502 of OH. 503 504 505
506 Figure 8. Geographical distribution in Mexico along the year in 2020, 2050, 2100 (RCP 4.5 and RCP 8.5) scenarios considering TT>23°C a) Map of CDH; b) Map 507 of OH. 508 509
32 576 Figure 13. Energy consumption scenarios in residential air conditioning in Mexico along the year in 2020, 2050, 577 2100 under the (RCP 4.5 and RCP 8.5) scenarios. 578 579 The results show that the trend in demand for cooling energy will increase throughout the 580 21st century. Similar weather patterns were observed in several areas of the republic; 581 therefore, a cluster analysis will be carried out to establish a preliminary classification of 582 regions in the entire area of Mexico that share similarities in their refrigeration requirements. 583 An information matrix was generated with data on energy consumption and hours of 584 operation of the simulations in its various scenarios; in the same way, the variables of ambient 585 temperature and relative humidity were annexed. The behavior of the data was studied 586 through a dispersion matrix, which can be seen in Fig. 14. Through this matrix, the data 587 correlation is analyzed; if there are evident patterns, there is a direct relationship between 588 variables, while, since an apparent behavior is not appreciated, a cluster study is required. 589 Fig. 14 can be analyzed from different perspectives; in the diagonal matrix, the behavior of 590 the study variables (ambient temperature, relative humidity, energy consumption, and hours 591 of operation) in the states of Mexico are exhibited considering the future variations of the 592 conditions environmental. It is observed that the states are divided into the consumption of 593 2020 2050_RCP 4.5 2050_RCP 8.5 2100_RCP 4.5 2100_RCP 8.5 kWh/m2 Energy consumption for air Conditioning per m2 of construction kWh Annual energy consumption in Air Conditioning 20 °C23 °C26 °C
33 fewer than 10 MWh and hours of operation in air conditioning equipment less than four 594 thousand hours in the states of the country's center, such as Morelos, Hidalgo. Subsequently, 595 there are energy consumptions between 11 MWh and 20 MWh, which result in operating 596 hours between 5,000 and 6,000 hours in certain states in the north of the country, such as 597 Baja California, and in the southeast, such as Chiapas and Tabasco. Lastly, there are states 598 with consumption more significant than 20 MWh and hours of operation more remarkable 599 than 6 thousand hours. This group comprises states from various parts of the republic, 600 northern areas such as Sonora and Chihuahua, and coastal areas such as Veracruz and 601 Sinaloa, ending in the country's southeastern region with Yucatan, Campeche, and Quintana 602 Roo. These operating parameters are directly related to environmental variables, which have 603 a wide distribution range, exceeding 30 °C in regions that will be the largest energy 604 consumers in air conditioning. Another analysis that results from Fig. 14 is the direct 605 relationship between ambient temperature and energy consumption; This is logical if one 606 considers that air conditioning equipment has more critical requirements as the room 607 temperature increases. With this dependence between ambient temperature and energy 608 consumption, ambient temperature is discarded for cluster analysis under the premise that its 609 behavior is reflected in energy consumption; regarding the other variables, the OH exhibit a 610 wide operating range from 3 thousand to 8 thousand hours. Relative humidity (RH) is 611 interesting to analyze, considering its high impact on OH and energy consumption. 612 Therefore, the variables considered in the cluster analysis are energy consumption, OH, and 613 RH. 614 615
34 616 Figure 14. Correlations and distributions of energy and environmental variables in the study area. 617 Next, the future distribution of energy consumption, OH, and RH of the 2,440 municipalities 618 that comprise the 32 states are presented in groups of conglomerates made through the k- 619 means method. Of the values considered reasonable for the number of clusters (𝜖 1, 2, 3, 620 …,8), k = 4 was selected as the value that best describes the data set. This value was acquired 621 by performing random initializations by calculating the sum of squares within the group for 622 each initialization [59]. Fig. 15 shows the behavior of the data and, when establishing 623 similarity of patterns between the municipalities of each state, obtaining the conglomerates. 624 The figure shows a wide range of values from 5 MWh to 25 MWh on the Energy 625 Consumption axis. However, when considering the RH, the stratification is simplified by 626 establishing each study municipality in three levels, grouping the clusters in a better way. 627 The first level is cataloged with zones of RH less than 40%, the second level comprises 628 regions with values between 40% and 65% RH, and finally, groups with RH more significant 629 than 70%. This pattern is interesting because RH is a significant parameter in energy 630 consumption. However, high values of RH do not need to lead to high energy consumption 631 values. Fig. 15 shows that RH is an essential environmental variable to consider in energy 632 analysis and categorization; however, currently in Mexico this parameter is not considered 633 within the classification of the various tariff schemes. 634 State
35 These pattern behaviors are set out more clearly in Table 5, which sets out the centroids of 635 each group. The first group comprises municipalities with energy consumption 636 characteristics of almost 7 MWh with RH of approximately 50%; this group has the largest 637 number of entities with more than 1,000 municipalities. The municipalities that make up this 638 conglomerate are in the country's central zone with the Edo. Mexico, Jalisco, Guanajuato, 639 Durango, etc., certain areas of the north with Tamaulipas and the southeast with Chiapas. 640 The second group is classified as having a higher energy consumption with a centroid of 10.7 641 MWh; however, the RH is established with 47%. The municipalities that make up this 642 conglomerate are mainly from the country's north, which will continue with the 643 meteorological trend of high ambient temperatures and low relative humidity. The entities of 644 this group are practically the state of Sonora, Chihuahua, and certain localities of Zacatecas 645 and Sinaloa. The third cluster comprises 374 municipalities located in the north of the 646 country, presenting an average consumption trend of 14 MWh. It is interesting to analyze 647 that this cluster is distributed by zones characterized by a low RH (65%), which will demand 648 high hours of operation in air conditioning equipment, exposing high ambient temperatures 649 throughout the year. Finally, the fourth group has the highest energy consumption in air 650 conditioning in the future, exceeding 18 MWh and with high RH values (77%). This 651 conglomerate comprises more than 600 municipalities geographically located in the 652 southeast, areas near the coast, and part of northern Mexico. 653
36 654 Figure 15. Cluster classification of energy and environmental variables. 655 656 Table 5. Centroids of each cluster group 657 Group Energy Consumption (MWh) Operation Hours (Thousands) RH (%) # Municipalities Cluster 1 6.88 4.6 57.9 1086 Cluster 2 10.7 4.7 43.3 283 Cluster 3 14.1548 5.5 65 374 Cluster 4 18.05 6.2 77.7 679 658 Fig. 16 shows the spatial distribution of energy and climatic conditions in the Mexican 659 Republic considering future behaviors. The nomenclatures of the zones are organized from 660 smallest to largest; thus, the C1 nomenclature corresponds to the group with the lowest 661 demand for air conditioning, and the C4 nomenclature to the group with the highest demand 662 for air conditioning. Group C1 is made up mainly of the states in the center of the country 663 (Ed. México, Querétaro, Hidalgo, Tlaxcala, Puebla), certain states near the coast such as 664 Oaxaca and Chiapas, part of the northeast of the country with Tamaulipas and municipalities 665 from Nuevo Leon and Coahuila. The last states are interesting to analyze because certain 666 municipalities are classified as C3 (14 MWh), demonstrating a high requirement for air 667
37 conditioning. In general, this conglomerate is distributed by regions with a temperate climate, 668 as it is in the center of the country, and due to the location and geographical characteristics 669 of the land, they will maintain comfortable temperatures in the future. Group C2 is 670 characterized by consumption of 10 MWh and a low RH (40%). It is observed in Fig. 16 that 671 the distribution of this conglomerate is the majority of the state of Sonora, Chihuahua, and 672 specific sectors of Zacatecas, Durango. These regions are characterized by having a dry 673 climate; however, the high ambient temperature and a considerable population distribution 674 will affect the increase in energy demand in the future. Group C3 (14.1 MWh) will present 675 the country's second highest air conditioning consumption. This group is made up of 676 municipalities from the state of Nuevo León, Coahuila, Tamaulipas, and Chiapas. 677 Interestingly, the states in this conglomerate have attached municipalities in group C1, which 678 has the lowest energy requirement. With this classification, significant climatological 679 variability is revealed within each state and the population distribution in specific cities. This 680 last section can be related to various aspects; however, within each state, local policies 681 classify each city according to specific characteristics that do not involve the population 682 index, which is why a high-energy activity is not guaranteed. The last C4 cluster emphasizes 683 the municipalities with the highest electricity consumption as a result of air conditioning (18 684 MWh). In Fig. 16, there are various regions throughout the national territory that make up 685 this group. Municipalities of the states of Baja California, Coahuila, Durango, Zacatecas, 686 Veracruz, and the southeast of the country with Yucatán, Quintana Roo and Campeche 687 comprise this conglomerate. This conglomerate's climatic diversity is evident; northern areas 688 are known to be dry regions and have variability in ambient temperature. While the southern 689 regions, throughout the year, have high relative humidity, increasing the thermal sensation. 690 At the national level, there is a tariff classification according to the ambient temperature. 691 With the results presented in Fig. 16, it is observed that studies must be carried out that 692 consider the trend of climate change and adjust the tariff schemes because it is notorious that 693 certain states will share a trend in energy consumption in the future. 694
38 695 696 Figure 16. Distribution of the states of the republic according to the cluster analysis k = 4. 697 698 5. Conclusions 699 This study analyzes the interior cooling trend in the Mexican Republic through the Weather- 700 based technical indexes: Cooling Degree Hour and Operation Hour. Cooling degree hour 701 were computed as the sum of hourly temperatures above a target temperature; while the 702 Operation Hour are the hours that require cooling equipment to reach the target temperature. 703 In this analysis It’s consider three cases of target temperature TT (TT = 20 °C, TT = 23 °C, 704 and TT = 26 °C). 705 The ambient temperatures were obtained through the METEONORM software for the years 706 2020, 2050, and 2100. Considering that the evolution of the climate is estimated with 707 projections associated with anthropogenic emissions of pollutants, an intermediate scenario 708 (RCP 4.5) was considered in the future climate data and a very high one (RCP 8.5) of 709 polluting gases. Evolutionary maps of energy requirements in space cooling were prepared. 710 Based on the results, the following conclusions are drawn: 711 C1 C2 C3 C4
39 - Mexico requires high levels of artificial air conditioning in cooling spaces, 712 specifically in the northern states, coastal regions, and the country's southeast. 713 - In less than 80 years, the demand for electrical energy for space cooling doubles 714 compared to the current scenario. 715 - The country's center has the lowest space cooling requirement, requiring less than 716 two thousand hours, while it exceeds five thousand hours in the north, southeast, and 717 coastal regions. 718 - The most significant cooling requirements are between 12:00 p.m. and 6:00 p.m., 719 with the tendency to increase demand by more than 40% for the years 2050 and 2100. 720 - The times of most significant energy demand in cooling equipment are spring and 721 summer, exceeding 110,000 hours per year. 722 The computational model is carried out under specific considerations, such as using 723 conventional air conditioning equipment with a COP standardized at 1.8. On the other hand, 724 the Housing model is standardized to deliver characteristics without modifications of the 725 inhabitants (construction, painting, extensions, Etc.) and with a north-south orientation. The 726 energy consumption in interior cooling was evaluated in social housing, the most widely 727 implemented in Mexico, through computational simulation, considering the construction 728 materials and operating patterns with three cases of target temperature TT. Subsequently, a 729 cluster study was carried out to group the states with the same cooling trend, establishing the 730 following conclusions: 731 - The high conductivity of construction materials affects the demand for cooling 732 interiors in buildings. 733 - Currently, more than 100 kWh is required to cool a construction m2, and it is projected 734 to increase by more than 20% and 35% for the years 2050 and 2100 in the various 735 RCP scenarios. 736 - Relative humidity is a variable that has a significant impact on energy consumption 737 in space cooling. 738 - In the cluster study, Mexico can be classified into four groups of requirements in 739 space cooling, projecting that some regions of the north and southeast of the country 740 require more than 18 MWh in energy for air conditioning. 741
40 The results of this work contribute to the generation of space cooling data in Mexico, 742 allowing the analysis of the energy demand trend under various climate change scenarios. 743 This work represents a starting point for the analysis of refrigeration in buildings through the 744 Cooling degree hour in the country. The methodology presented when making the 745 appropriate modifications can be used in regions with high climatic variability between 746 summer and winter, requiring the application of heating. This work shows that Mexico's 747 construction materials are not suitable for various regions of the country due to its climatic 748 variability. This causes a deficit of satisfactory thermal comfort conditions for the occupants. 749 According to [60], this indicates the presence of energy poverty for the large percentage of 750 the Mexican population living in this housing type. These results, in the same way, promote 751 the investigation of thermal analysis of various materials or the application of passive systems 752 in the construction scheme of housing in the country. 753 On the other hand, through cluster analysis, the impact of relative humidity was observed as 754 an element that determines energy consumption in homes in the country. Said variable is not 755 considered in the Mexican subdivision of the domestic tariff scheme [61]. In addition, the 756 results show that this parameter allows energy subclassification for energy use in housing. 757 The results establish the need to restructure tariff schemes that do not have advanced 758 regulations considering meteorological variability and climate change. On the other hand, a 759 comparison can be made regarding the energy requirements for refrigeration and pollutants 760 emitted to the environment in the residential sector by using adaptive thermal comfort 761 models. 762 763 Declaration of competing interest 764 The authors declare that they have no know competing financial interest or personal 765 relationship that could have appeared to influence the work reported in this paper. 766 767 Acknowledges 768 The first author (Mario Jimenez) is thankful for the financial support granted by CONACYT 769 (CVU No. 930301, scholarship no. 785382) to pursue a doctoral grand in Universidad 770 Autónoma de Yucatán, México. The authors acknowledge the support provided by the 771 Thematic Network 722RT0135 “Red Iberoamericana de Pobreza Energética y Bienestar 772
41 Ambiental” (RIPEBA) financed by the call for Thematic Networks of the CYTED Program 773 for 2021. 774 775 References 776 1. Pérez-Andreu V, Aparicio-Fernández C, Martínez-Ibernón A, Vivancos J-L (2018) 777 Impact of climate change on heating and cooling energy demand in a residential 778 building in a Mediterranean climate. Energy 165:63–74. 779 https://doi.org/10.1016/j.energy.2018.09.015 780 2. Tobin P, Schmidt NM, Tosun J, Burns C (2018) Mapping states’ Paris climate pledges: 781 Analysing targets and groups at COP 21. Glob Environ Chang 48:11–21. 782 https://doi.org/10.1016/j.gloenvcha.2017.11.002 783 3. Intergovernmental Panel on Climate Change I (2014) Summary for Policymakers. In: 784 Intergovernmental Panel on Climate Change (ed) Climate Change 2013 - The Physical 785 Science Basis. Cambridge University Press, Cambridge, pp 1–30 786 4. Statista (2022) • CO2: emisiones mundiales 1995-2021 787 5. International Energy Agency I (2020) Global Energy Review 2021. Glob Energy Rev 788 2019. https://doi.org/10.1787/90c8c125-en 789 6. Ciancio V, Salata F, Falasca S, Curci G, Golasi I, de Wilde P (2020) Energy demands 790 of buildings in the framework of climate change: An investigation across Europe. 791 Sustain Cities Soc 60:102213. https://doi.org/10.1016/j.scs.2020.102213 792 7. González-Torres M, Pérez-Lombard L, Coronel JF, Maestre IR, Yan D (2022) A 793 review on buildings energy information: Trends, end-uses, fuels and drivers. Energy 794 Reports 8:626–637. https://doi.org/10.1016/j.egyr.2021.11.280 795 8. Ciancio V, Falasca S, Golasi I, Curci G, Coppi M, Salata F (2018) Influence of Input 796 Climatic Data on Simulations of Annual Energy Needs of a Building: EnergyPlus and 797 WRF Modeling for a Case Study in Rome (Italy). Energies 11:2835. 798 https://doi.org/10.3390/en11102835 799 9. Milojevic-Dupont N, Creutzig F (2021) Machine learning for geographically 800 differentiated climate change mitigation in urban areas. Sustain Cities Soc 64:102526. 801 https://doi.org/10.1016/j.scs.2020.102526 802 10. Manzano-Agugliaro F, Montoya FG, Sabio-Ortega A, García-Cruz A (2015) Review 803 of bioclimatic architecture strategies for achieving thermal comfort. Renew Sustain 804 Energy Rev 49:736–755. https://doi.org/10.1016/j.rser.2015.04.095 805 11. Salehi A, Torres I, Ramos A (2017) Assessment of ventilation effectiveness in exiting 806 residential building in mediterranean countries: Case study, existing residential 807 building in Portugal. Sustain Cities Soc 32:496–507. 808 https://doi.org/10.1016/j.scs.2017.04.018 809 12. Pandey B, Banerjee R, Sharma A (2021) Coupled EnergyPlus and CFD analysis of 810 PCM for thermal management of buildings. Energy Build 231:110598. 811 https://doi.org/10.1016/j.enbuild.2020.110598 812 13. Gamero-Salinas J, Monge-Barrio A, Kishnani N, López-Fidalgo J, Sánchez-Ostiz A 813 (2021) Passive cooling design strategies as adaptation measures for lowering the 814 indoor overheating risk in tropical climates. Energy Build 252:111417. 815 https://doi.org/10.1016/j.enbuild.2021.111417 816 14. Cruz May E, el Mekaoui A, Livas-Garcia A, Mejía-Montero A, Bassam A (2022) 817