scieee AI-readable full text Open interactive document viewer

Reconstruction of events recorded with the surface detector of the Pierre Auger Observatory

Aab, A.,Bueno Villar, Antonio

Abstract

Argentina - Comisión Nacional de Energía Atómica

Full text

Journal of Instrumentation Reconstruction of events recorded with the surface detector of the Pierre Auger Observatory To cite this article: A. Aab et al 2020 JINST 15 P10021 View the article online for updates and enhancements. This content was downloaded from IP address 150.214.205.97 on 05/02/2021 at 08:19 2020 JINST 15 P10021 Published by IOP Publishing for Sissa Medialab Received:July 20, 2020 Accepted:August 24, 2020 Published:October 21, 2020 Reconstruction of events recorded with the surface detector of the Pierre Auger Observatory The Pierre Auger collaboration E-mail: [email protected] Abstract: Cosmic rays arriving at Earth collide with the upper parts of the atmosphere, thereby inducing extensive air showers. When secondary particles from the cascade arrive at the ground, they are measured by surface detector arrays. We describe the methods applied to the measurements of the surface detector of the Pierre Auger Observatory to reconstruct events with zenith angles less than 60◦using the timing and signal information recorded using the water-Cherenkov detector stations. In addition, we assess the accuracy of these methods in reconstructing the arrival directions of the primary cosmic ray particles and the sizes of the induced showers. Keywords: Data Processing; Large detector systems for particle and astroparticle physics; Large detector-systems performance; Performance of High Energy Physics Detectors ArXiv ePrint:2007.09035 c 2020 The Author(s). Published by IOP Publishing Ltd on behalf of Sissa Medialab. Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. https://doi.org/10.1088/1748-0221/15/10/P10021 2020 JINST 15 P10021 Contents 1 Introduction 2 2 The surface detector 4 3 Reconstruction at the level of the station 5 3.1 Calibration 5 3.2 Determination of the baseline 6 3.3 Identification of the time range of interest 7 3.4 Estimation of the signal 8 3.5 Uncertainties in the measurement of the signal 9 4 Building events 10 5 Reconstruction of events 12 5.1 Shower geometry 12 5.2 Shower size 14 5.2.1 Lateral distribution function 15 5.2.2 Maximum-likelihood procedure 16 6 Angular resolution 19 6.1 Derivation from measurements 20 6.1.1 Hybrid data 20 6.1.2 Super-hexagon of multiplets 20 6.1.3 Sub-arrays 21 6.2 Estimation using simulations 21 6.3 Comparison of results 22 7 Uncertainties in S(1000)23 7.1 Fit uncertainties and model-dependent systematic errors 23 7.2 Direct measurements 24 7.2.1 Super-hexagon of multiplets 24 7.2.2 Sub-arrays 25 7.3 Estimation using simulations 25 7.4 Comparison of results 25 8 Towards an efficient estimate of the energy 26 9 Conclusion and outlook 27 The Pierre Auger collaboration 32 –1– 2020 JINST 15 P10021 1 Introduction The intensity of cosmic rays with energies above ∼1014 eV is only a few particles per square meter per day and thus too low to allow for direct measurement with satisfactory statistical precision. The phenomenon of extensive air-showers must therefore be exploited to study cosmic rays at higher energies. In extensive air-showers, the interaction of a primary cosmic-ray with Earth’s atmosphere induces a cascade of particles, where the particles reaching the ground may be sampled by large arrays of detectors. The higher the energies of primary cosmic rays, the lower is their arrival rate such that increasingly larger detection areas are needed to counteract the lower intensity. Meanwhile, the higher the primary energy, the larger are the dimensions of the resulting air shower such that an increased spacing between detectors is sufficient to ensure shower detection. For example, the footprint at sea level of a shower generated by a primary cosmic-ray with an energy of 1019 eV is ∼10 km2, and it has been found empirically over the years that having several detectors inside such an area is sufficient to reconstruct the properties of such showers. Above 1019 eV, the intensity is only ∼1per km2per year, which therefore requires huge collecting areas to gather adequate statistics. A shower can be thought of as a thin, radially extended, and slightly curved disk of particles propagating longitudinally at the speed of light along the initial direction of the primary cosmic-ray. At every stage of development, the particle density in the disk is largest at the center, or core, of the shower and decreases with radial distance from the shower axis. At sea level, about 90% of the energy flow lies within less than 100 m of the shower axis; however, gathering a reasonable number of events here would require a prohibitively dense array and a large dynamic range of the particle detectors. A sparse array of detectors at the ground can only sample the disk at a fixed stage of shower development and only beyond a certain distance from the core. The arrival direction and a proxy of the shower size can nevertheless be reconstructed and interpreted in terms of the properties of the initial cosmic ray without the need for deeper insight into the complex physics of extensive air-showers, where the latter quantity can be used to infer the energy of the primary particle. The arrival direction of the primary cosmic-ray can be determined from the relative times of arrival of the shower disc at the dispersed detectors. This was first demonstrated in the 1950s by the researchers in the MIT group [1], who used their newly-developed liquid scintillation detectors to show, for the first time, that the shower disc was sufficiently thin to enable determination of the direction of the shower axis to within a few degrees. Since then, the detectors of choice have either been scintillators (liquid or plastic) or water-Cherenkov detectors, the use of which was pioneered a few years later [2]. Thenumberofparticlesin theshower (also referredtoas theshower size) atthe observation level is related to the primary energy, but because of fluctuations in shower development, the association is not a simple one. A lower-energy primary particle that interacts deep in the atmosphere can create a cascade which has the same size at the ground as the one produced by a more energetic particle interacting higher in the atmosphere. Measuring the shower size at the depth of the shower maximum (or better, the integral of the deposited energy along the shower profile) reduces the impact of such fluctuations; however, observations at the shower maximum have only been possible at high altitudes and for relatively low-energy events (see e.g. [3]), or by the observation of the profile with fluorescence detectors [4,5], albeit with an order of magnitude lower duty cycle. –2– 2020 JINST 15 P10021 When considering depths lower in the atmosphere than the position of the shower maximum, and when using a widely-spaced array of detectors, the situation is more complex. Determining the fall-off of the signal as a function of distance from the axis is difficult when the spacing of the detectors is large, and it cannot be determined with adequate precision on an event-by-event basis. A technique to circumvent this problem was introduced by Hillas [6], who proposed using the signal at a distance appropriate for the separation of the detectors at which the uncertainty in the determination of this signal is least susceptible to the lack of knowledge of the fall-off of the signal with distance. The Pierre Auger Observatory [7] is the world’s largest extensive air-shower detector and makes use of these techniques to study cosmic rays at the highest energies. The hybrid design of the Observatory consists of 27 telescopes of the fluorescence detector (FD) [8] distributed between four sites overlooking the huge array of the surface detector (SD). The SD, described in the following section, provides the bulk of the events recorded by the Observatory, which are principally used to measure the distribution of arrival directions (e.g. [9]) and the energy spectrum (e.g. [10]) of the highest-energy cosmic rays. The reconstruction of these SD events is the focus of this paper. In this document, we provide a detailed description of the methods used to reconstruct the arrival direction and size of an extensive air-shower from the magnitudes and temporal distributions of signals detected in each SD station. A critical evaluation of the accuracy of the reconstruction procedure is also an essential part of this work. The methodology described here is used only for events with a zenith angle θ < 60◦, as the reconstruction of more inclined showers requires different methods due to the substantial asymmetry induced in the spatial distribution of the shower particles by the geomagnetic field and due to geometrical effects [11]. Within the Pierre Auger Collaboration, two independent frameworks have been developed for the reconstruction of these events with the corresponding releases of reconstructed data dubbed Herald and Observer [12]. The existence of these independent analyses facilitates easy access to cross-checks, validations, and verification of systematic effects. The two reconstructions are based on a similar strategy; however, they include slight differences in the description of the temporal and lateral structure of showers. Such differences are highlighted where relevant. The paper is organized as follows. In section 2, we give a brief introduction to the features of the SD relevant for the reconstruction procedures. In section 3, we describe the treatment of the data from individual detectors, including the derivation of the start-times and the magnitudes of the recorded signals. In section 4, we describe how shower events are built prior to the reconstruction procedure. In turn, this reconstruction procedure is described in detail in section 5, beginning with the methods used to reconstruct the geometry of the shower (arrival direction of the shower and the impact point of the core) and ending with the estimation of the shower size. In section 6 and in section 7, the uncertainties associated with the reconstructed parameters are discussed. In section 8, we finalize the description of the reconstruction procedures by briefly outlining the assignment of energy. –3– 2020 JINST 15 P10021 2 The surface detector The SD consists of more than 1600 water-Cherenkov stations arranged on a isometric triangular grid covering 3000km2. Station elevations range between 1300 and 1600 m above sea level, and each station is separated from its six nearest neighbors by approximately 1500 m. For example, a primary cosmic ray with an energy of 1019 eV will trigger at least 5, but on average ∼8, stations. Within the boundary of the 1500m array, there are two denser regions: one extending over 28 km2 within which the stations are spaced 750 m apart from one another, and the other covering 2 km2 with 433 m spacing. For events recorded in these parts of the SD, specific reconstructions are developed based on the reconstruction given here, but appropriately scaled to a smaller spacing. A detailed description of the SD can be found in [7], and only the main features relevant to the work presented in this paper are summarized here. Each station is a cylindrical container with a base area of 10 m2. These containers are filled to a depth of 1.2 m with highly purified water enclosed by a diffusively-reflective liner. The volume of water is viewed from above by three 9-inch photomultiplier tubes (PMTs), which detect Cherenkov light emitted during the passage of charged particles. Each PMT provides two signals which are tagged with the GPS time stamps to an absolute time accuracy of ∼12 ns [13] and are digitized by 40 MHz, 10-bit Flash Analog-to-Digital Converters (FADCs). The low-gain signal is taken directly from the anode of the PMT, while the high-gain signal is provided by the last dynode and amplified to be nominally 32 times larger than the low gain, thus enlarging the total dynamic range to span more than three orders of magnitude in integrated signal. The data acquisition is governed by a hierarchical system of triggers implemented in hardware and software. The first two levels, T1 and T2, are formed locally by each detector station [14]. The set of stations passing the T2-level criteria are continuously examined remotely for temporal and spatial coincidences in at least three stations. Upon identification of such a coincidence, an array-level trigger T3 is issued by the central data acquisition system (CDAS). After the T3 trigger is raised, FADC data from the T1 and T2-triggered stations, as well as calibration and monitoring data, are transmitted to CDAS by means of local-area-network radio-communication. Additional higher-level triggers are then implemented off-line to select shower events (physics trigger T4) and to ensure the shower is well contained in the array. With respect to the latter, we employ a fiducial trigger NT5, where Nis the number of functioning stations surrounding the station with the highest signal at the time of the event. In this work we consider only the most stringent condition, the 6T5, where all six neighboring stations must have been present and functioning. This ensures an accurate reconstruction of the impact point. For the data set used in this work, 6T5 events1from the period of 1 January 2004 to 31 December 2018 have been selected, resulting in a set of more than 400 000 events. However, the results discussed in this paper also apply to the events with a less conservative trigger 5T5, which have been used in anisotropy studies where it is advantageous to counterbalance the slightly reduced reconstruction accuracy with larger statistics [9,15,16]. The whole acquisition chain, starting from the single-station trigger up to the off-line event selection, reduces the counting rate of single stations from about 3000/s, due mainly to single uncorrelated atmospheric muons [17], down to about 3×10−5/s for high quality physics 1This requirement not only ensures adequate sampling of the shower but also allows evaluation of the aperture of the SD in a purely geometrical manner in the regime where the array is fully efficient [14]. –4– 2020 JINST 15 P10021 x / km 6−4−2−0 2 4 6 y / km 6− 4− 2− 0 2 4 6 Figure 1. Example of a shower event detected by the SD, which is reconstructed with θ=55.2◦and an energy of 38.7 EeV. Left: schematic depiction of the surface detector array in which each dot represents a surface detector station. The colored stations correspond to those participating in this example event. Rays correspond to the field of view of the telescopes at the four FD sites. Right: a zoomed-in, top-down view of the example event falling within the array. The projection of the shower axis on the ground is represented by the black line, ending at the impact-point of the shower-core (red square). The SD stations are colored according to their trigger time (blue is early, green is late) with their area proportional to the logarithm of the signal. events. Consequently, a rate of events across the complete array of about 0.05/s is measured, which is almost entirely due to extensive air showers. The footprint of one such event is shown in figure 1and is used in the examples that follow in later sections. 3 Reconstruction at the level of the station For recorded events, the treatment of signals starts at the station level. In this section, we describe the treatment of the FADC traces2for each PMT in stations passing the T1 or T2 trigger conditions. These procedures provide a common standard to which all surface detector stations are calibrated. Additionally, they provide a start time and a signal magnitude. The uncertainties related to each of these are also discussed. 3.1 Calibration The aim of the calibration is to enable a conversion of the signals recorded by the three PMTs and electronics of each station from the unit of ADC-counts to the reference unit of a vertical equivalent muon (VEM). The VEM is the charge associated with a vertical muon passing through 2A few traces (<3%) can in fact show anomalies due to hardware problems either in the PMTs or in the electronics: these are identified prior to the analysis by means of the monitoring data and excluded from the reconstruction. –5– 2020 JINST 15 P10021 / ADCTQ 100 200 300 400 500 600 700 800 0 200 400 600 800 1000 1200 1400 1600 fit of the atmospheric muon peak local maximum at: 232.2 ADCT bins Figure 2. The calibration of individual stations is performed by collecting 60s of background signals. The histogram above is an example of the sizes of integrated signals Qin units of ADCT = ADC count ×time bin. The position of the peak (local maximum) at Q=∼232 ADCT, created by the atmospheric background muons, is used as the reference value for conversion of station signals into units of VEM. the center of the station and also corresponds to ∼240 MeV of energy deposited due to ionization losses of the passing muon. [18]. This conversion factor, Qpeak VEM, is evaluated online by constantly measuring the properties of particles entering the detector volume at a rate of ∼3/s. The on-board SD electronics are used to record histograms of the digitized pulse-heights and integrated charges from a minute’s worth of background particles. An example of such a charge histogram is shown in figure 2. These histograms are stored alongside and exported with event data, thereby enabling the off-line re-evaluation of the VEM unit with 3% accuracy. The calibration factor Qpeak VEM is the position of the local maximum corresponding to the most probable charge deposited by muons coming from all directions, which is proportional to the VEM. In each event, the FADC traces are independently calibrated for each PMT using the background data recorded in the preceding minute. Dynamic station-by-station conversion of all signals into units of VEM facilitates preservation of a stable and uniform response to shower particles across the array. 3.2 Determination of the baseline The first step in the signal processing is the estimation of the baseline of the high-gain and lowgain traces of each PMT separately. Since the baseline of a trace can be affected by the signals themselves, it is not estimated as one single value for the whole trace. Instead, the algorithm allows for a changing baseline along the trace. Constant baseline segments are identified as at least 40 consecutive bins (i.e. with a duration of at least 1µs) that vary in amplitude by less than ¯y±σb, where ¯yis the mean of the baseline segment and σbis the tolerance needed to account for the possible noise in the baseline. σbis set to 2ADC counts. In rare cases (<0.2%), when the PMT in question is noisy, the tolerance σbis increased in steps of 1 until a constant baseline segment is found. These baseline segments, illustrated by the green boxes in figure 3-top are then combined to form the total baseline. Each of the bins corresponding to a baseline segment is inserted into the total baseline as a constant value given by ¯yof that baseline segment. Then, the parts between the –6– 2020 JINST 15 P10021 Time / 25 ns 100 200 300 400 500 600 FADC Counts 40 60 80 100 120 140 Time / 25 ns 100 200 300 400 500 600 FADC Counts 40 60 80 100 120 140 Figure 3.Top: illustration of the baseline estimation (red), constructed from the individual segments (highlighted in green) and interpolation, on a high-gain FADC trace of a PMT. Bottom: identification of signal fragments (magenta filled boxes) and the final merged signal window (large dotted cyan box). Based on the number of peaks, this trace probably contains ∼5muons with some additional electromagnetic component. Trace start and stop times are denoted with the vertical dashed red and blue lines, respectively. baseline segments are filled with values interpolated linearly in integrated signal, which results in an estimation of the baseline covering all of the 768 bins constituting the trace as shown with the red line in figure 3. 3.3 Identification of the time range of interest The next step is the extraction of the relevant signal from the traces of individual PMTs, i.e. identifying the start and stop time of the signal, which is always performed on the high-gain channel due to its superior resolution. As in the baseline case, the FADC traces are first scanned to identify candidate signal fragments, which consist of consecutive bins with amplitudes of at least 3ADC counts above the baseline. Examples of identified signal fragments are indicated in figure 3-bottom with magenta boxes. After the subtraction of the baseline in each PMT, traces are calibrated in VEM units using the value of Qpeak VEM. To avoid inclusion of background signals (mostly single, unaccompanied muons), the candidate fragments are additionally scrutinized before being merged into the final signal segment. Two consecutive fragments A and B can only be merged if they fulfill both of the following requirements: 1. Fragment B must begin less than 500 ns (20 time bins) + tAafter the end of fragment A, where tAis the amount of time in fragment A containing signal. 2. The integral of fragment A must be greater than 30% of the integral of fragment B, or fragment B must have an amplitude below 5Ipeak VEM, where Ipeak VEM is the mean amplitude of the background muons [18]. This procedure is repeated for all consecutive fragments until all fragments are processed and signal segments are created. In figure 3-bottom, the final signal segment resulting from the merging of the candidate fragments (magenta) is indicated with a dotted cyan box. –7– 2020 JINST 15 P10021 Distance to shower axis / m 500 1000 1500 2000 2500 3000 Delay from plane front / ns 0 200 400 600 800 1000 Observer Spherical front Herald Parabolic front ° / η 0 0.5 1 1.5 2 2.5 3 ηd/Nd 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0 10 20 30 40 50 60 ° / ϕ∆ 1−0.5−0 0.5 1 ° / θ∆ 1− 0.5− 0 0.5 1 Figure 6.Left: for the large example event from figure 1, the start times in individual stations are shown as a function of the distance to the shower axis for the Herald (red triangles) and Observer (blue circles) reconstructions. The times are relative to the arrival time of the corresponding plane front. The solid lines represent the predicted time for the spherical model (eq. (5.4), blue) and the parabolic model (eq. (5.3), red). Right: distribution of the angular difference η, where sin η=|ˆap׈as|, between the axes of the two curved shower-front models: ˆapfor the paraboloid and ˆasfor the spherical model. The distribution has been fitted with a weighted sum of two Rayleigh distributions from which we can derive that 68% of reconstructed events have arrival directions which agree to within 0.40◦.Inset: 2D distribution of the differences in the zenith angle, ∆θ=θs−θpand in the azimuthal angle, ∆ϕ=ϕs−ϕp. the increasing delays of signal start-times with respect to the arrival of a plane front tangential at the shower core. The angular differences between the axes of the two reconstructions are shown in figure 6-right, from which we can conclude that 68%, 90%, and 95% of all the events are reconstructed within an angular difference of less than 0.40◦,0.83◦, and 1.14◦, respectively. The small, non-zero difference of less than 0.1◦observed in ∆θwill be addressed in section 5.2.1. 5.2 Shower size The shower size is estimated with a regression of the parameters of the lateral distribution function (LDF), S(r), to the signals in the triggered stations and is additionally constrained by the absence of triggers in stations which would have measured very little or no signal. The LDF is a function of the perpendicular distance to the shower axis, r. However, showers induced by identical primaries (i.e. with the same energy, mass, and arrival direction) can be sampled at the ground at different stages of development due to the shower-to-shower fluctuations arising from the variability of the location and the nature of the leading interactions, and the variability of the subsequent development of the cascade. This results in a natural variability of the shower size, the mean value of which depends on the mass of the primary particle. For the majority of events, the multiplicity and spatial distribution of triggered stations in the shower plane is insufficient to precisely estimate the shower size and determine the shape of the LDF. Instead, station signals of individual events are fitted with a scaled, data-derived average LDF shape fLDF(r)such that S(r)=S(ropt)fLDF(r),(5.5) – 14 – 2020 JINST 15 P10021 where S(ropt)is the shower-size estimator and fLDF(r)is normalized so that fLDF(ropt) ≡ 1. The optimal value for distance ropt has been chosen so that the variability of the shower-size estimator S(ropt)with respect to the aforementioned shower-to-shower fluctuations is minimized. The value almost exclusively10 depends on the spacing and structure of the array [24]. In the case of the Auger SD, where the array is an isometric triangular grid with a spacing of 1500 m, the optimal distance amounts to ropt ≈1000 m, so we have decided to fix it at exactly 1000 m and denote the corresponding shorthand for the shower-size estimator as S(1000). 5.2.1 Lateral distribution function Due to the lack of analytical solutions for the hadronic-cascade equations, functional forms for fLDF(r)have traditionally been chosen empirically (see [25] for an overview of functional forms chosen for previous experiments). The Herald reconstruction uses a log-log parabola, ln fLDF(r)=β ρ +γ ρ2,(5.6) where ρ=ln(r/ropt)and β,γare the average slope parameters of the LDF. For smaller axial distances, r<rcwhere rc=300 m, a tangential log-log linear function β ρ +γ(2ρ−ρc)ρcis used where ρc=ln(rc/ropt). The Observer reconstruction instead uses a slightly modified NKG function [26–28] of the form fLDF(r)=r ropt βr+rs ropt +rsβ+γ ,(5.7) with a fixed rs=700 m. The average of the slope parameter βis determined in both cases in a data-driven way, by fitting βfor the subset of events with a multiplicity and spatial distribution of stations providing a sufficient lever arm. In these events, the slope βis fitted given that there are at least 2, 3, or more stations within a radius of 400 <r/m<1600 and that at least two of the stations are separated by 900, 800, or 700 m, respectively. This lever-arm criteria ensures that the lateral distribution is sufficiently sampled around the distance of 1000 m to constrain the slope of the LDF well. Due to the strong correlation between βand γ, it is more difficult to determine the average of the slope parameter γin a data-driven way in the case of both LDF functions. In eqs. (5.6) and (5.7), the parameter γis describing the deviation of the LDF from a simple power-law function at large distances. In the Observer reconstruction, similar lever-arm criteria are used to fit γexcept the station search radius is changed to 1000 <r/m<2000. In the Herald reconstruction, the parameter γhas been determined from Monte-Carlo studies. Finally, both parameters βand γare parametrized as functions of the zenith angle and S(1000). Both LDF models used within the Auger Collaboration assume that the deposited signals in the stations are rotationally symmetric around the shower axis. In truth, the showers are asymmetric due to a combination of the longitudinal evolution and geometrical effects related to the angles of incidence of the particles on the stations. The Herald reconstruction corrects for these asymmetries with an unbiasing model applied to the measured signals Ssymm(r)=S(r) 1+α(r)cos ζ,(5.8) 10ropt depends only at ∼5% level on the choice of the LDF form, the primary energy, and the zenith angle. – 15 – 2020 JINST 15 P10021 where ζis the azimuthal angle of the station (as measured in the shower plane where ζ=0 corresponds to the upstream direction) and where the radial dependence of the amplitude α(r)has been obtained from simulations. These corrections are only important in very specialized studies as they only result in small shifts of ∼40 m in the estimate of the position of the shower core, which is well within the typical uncertainties of the reconstruction. These corrections ultimately have a <0.2% effect on the value of S(1000)and a <0.2◦effect on the axial direction, as estimated by performing the Herald reconstruction with and without their application. The exact magnitudes of these effects depend on the zenith angle and state of development of the shower. Since no asymmetry correction is applied in Observer, the corresponding shift of the impact-point is also responsible for the very small, yet systematic differences in arrival directions reconstructed by the two reconstructions, where ∆θ < 0.1◦as seen in figure 6-right. 5.2.2 Maximum-likelihood procedure Using the results of the reconstruction of the shower geometry, the fit to the LDF is, in the next step, maximized using the likelihood L, composed as the product of probabilities Pover the coordinates of the shower impact point ® xcand the size S(1000), given the observed signal sizes Siin the stations, located at ® xi. We are thus maximizing the log-likelihood ln L=Õ i ln P(S(1000),® xc|Si,® xi).(5.9) Thetwo reconstructions use different modelsforcalculationof thelikelihood P. In the Observer framework, Pis a product of contributions from: (a) stations with small signals, (b) stations with large signals, (c) stations with saturated signals, and (d) non-triggered stations. The individual terms are as follows: (a) Small signals. For a small signal Si<Sstat where Sstat ≈20 VEM, the likelihood is modeled as a Poissonian probability fPoi(Si,S(ri)), with the signal scaled to a particle count for which the corresponding Poisson variance matches the signal variance from eq. (3.2), and where S(ri) is, according to the LDF of eq. (5.5), the expected signal at the radial distance ri=rˆa(® xi−® xc) from eq. (5.2). (b) Large signals. For a large number of particles the distribution of the signal is modeled with a Gaussian approximation N(Si;S(ri), σi)which is used for large signals Si⩾Sstat and where σi=σS(ri)according to the eq. (3.2). (c) Unrecoverable saturated signals. For saturated signals that fail the signal recovery procedure, mentioned in section 3.4,Siis treated only as a lower limit to the actual size of the signal. The Gaussian function Nfor large signals is integrated over all possible values larger than Sito get an estimate Fsat(Si,S(ri)) of the probability of detecting a signal larger than Si, but only when no signal recovery is applied. (d) Non-triggered stations. To trigger, a station has to acquire a certain amount of signal, a process that can be modeled with a trigger probability ptrig(S(ri)), which is derived from data [14]. The complementary probability for non-triggered stations is thus modeled as Fnon(S(ri)) =1−ptrig(S(ri)). – 16 – 2020 JINST 15 P10021 / VEM) fix (1000)Slg( 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 fix (1000)S(1000) / S∆ 0.08− 0.06− 0.04− 0.02− 0 0.02 0.04 0.06 0.08 Saturated All (1000) / VEM)Slg( 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 Fraction of saturated events [%] 0 10 20 30 40 50 60 70 80 90 100 Figure 7.Left: relative difference of the shower size due to the treatment of βas a free or fixed parameter, obtained with the Observer reconstruction where ∆S(1000)=S(1000)free−S(1000)fix. The relative difference is shown for all events in addition to events where a station saturated. Right: fraction of saturated events as a function of the shower size. This results in a likelihood function L= Nsmall Ö i fPoi(Si,S(ri)) Nlarge Ö iN(Si;S(ri), σi) Nsat Ö i Fsat(Si,S(ri)) Nnon Ö i Fnon(S(ri)).(5.10) For the Herald reconstruction, the LDF likelihood function is split into two parts based on whether stations have triggered or not. While for the triggered stations, the signal Siis assumed to be a Gaussian fluctuation around an average value S(ri)given by the eq. (5.6), for the non-triggered stations, the relevant likelihood term is given, as in Observer, by the complementary probability. The Herald reconstruction maximizes a likelihood function L= Nsig Ö iN(Si;S(ri), σi) Nnon Ö i Fnon(S(ri)).(5.11) For showers with triggered stations satisfying the lever-arm conditions and thus ensuring a strong constraint on the slope of the LDF in eq. (5.6), the parameter βis always fitted in the Herald reconstruction. In the Observer reconstruction, the parameter βcan be set as a free parameter for the same set of showers. A comparison of the shower sizes obtained with βas a free or fixed parameter of the LDF in eq. (5.7) is shown in figure 7-left. The impact of freeing or fixing βamounts to a less than 3% (4%) bias in the reconstructed value of S(1000)for non-saturated (saturated) events and, therefore, fitting of βis not required to obtain an unbiased estimate of the shower size [6,29]. The fraction of all events which are saturated is ∼11% but strongly depends on shower size as depicted in figure 7-right. The fraction is constant to within 2% across the full range of zenith angles. Using the Herald reconstruction, one final, global reconstruction step is performed to account for the coupling between the geometry and the LDF fits. Depending on the number of degrees of freedom, any parameters which were previously fixed are at this stage allowed to vary. The global log-likelihood function −2 ln Lglobal =χ2−2 ln L(5.12) is minimized, where the two terms are given in eqs. (5.1) and (5.11). – 17 – 2020 JINST 15 P10021 Distance to shower axis / m 500 1000 1500 2000 2500 3000 Signal / VEM 1 10 2 10 3 10 Observer Modified NKG Herald Log-Log Parabola / m c x∆ 0 50 100 150 200 250 300 350 400 450 500  c x∆d/Nd 0 0.01 0.02 0.03 0.04 0.05 0.06 0 20 40 60 80 100 120 / mx∆ 200−100−0 100 200 / my∆ 200− 100− 0 100 200 Figure 8.Left: the lateral distribution of signals from the example event in figure 1is plotted as a function of the radial distance of stations from the shower axis, shown for both Herald (red triangles) and Observer (blue circles) reconstructions, along with their respective LDFs, eqs. (5.6) and (5.7). The reference signals at the radial distance of 1000m are indicated by the dashed line with values of S(1000)=112 VEM and 107 VEM for this particular event. See figure 1for the image of the corresponding footprint. Right: distribution of distances, |∆® xc|=|® xLLP c−® xNKG c|between the impact points reconstructed in two different ways: with a Log-Log Parabola (LLP) LDF in Herald and a modified NKG in Observer. The distribution has been fitted with a Rayleigh function (red line) indicating that in 68% of the events, the two reconstructed impact points are at a distance smaller than 92m. Inset: 2D distribution of ∆x=xLLP −xNKG and ∆y=yLLP −yNKG. These coordinates have been computed in the reference frame of the Observer shower and are oriented so that the positive/negative ∆yaxis is in the down/upstream direction. The reconstructions described above successfully converge more than 99% of the time. The convergencefailuresaremostly dueto low-multiplicityeventsformedbyrandomcoincidenceswhich only by chance pass our selection procedures. It is important to note that using the non-triggered stations adds a significant geometrical constraint to the LDF fit, in particular for low-multiplicity events. Without consideration of the non-triggered stations, deviations of the shower size on the order of up to 8% are observed. An example of the LDF fits obtained with the Herald and Observer reconstructions is shown in figure 8-left. In this example, the two LDF fits give very similar results for the estimation of the shower size S(1000). The differences between the two LDFs (defined in eqs. (5.6) and (5.7)) are due to uncertainty in the shape of the underlying lateral distribution close to and far from the shower core. These differences lead to a distribution of distances |∆® xc|between the shower impact points shown in figure 8-right. For the two reconstructions, 68% of the events exhibit a difference of less than 100 m. The systematic differences in the positions of the impact points (as shown in the inset of figure 8-right) are largely due to the asymmetry correction defined in eq. (5.8), which is only employed in the Herald reconstruction. In figure 9, a similar comparison is shown for the shower-size parameter S(1000). The skewness of the distributions seen in figure 9-right is a consequence of a zenith-angle dependence of the systematic difference between the two reconstructions of S(1000). These systematic differences are corrected for in the angular portion of the calibration procedure, which is described in section 8. The fit of S(1000)Herald vs. S(1000)Observer shows that the correlation between the two reconstructions follows a simple power law. Deviations from this power law do not exceed 3% at any point across – 18 – 2020 JINST 15 P10021 / VEM) Observer (1000)Slg( 0 0.5 1 1.5 2 2.5 3 / VEM) Herald (1000)Slg( 0 0.5 1 1.5 2 2.5 3 0 50 100 150 200 250 [%] Observer (1000)S(1000)/S∆ 150−100−50−0 50 100 150 Entries 1 10 2 10 3 10 4 10 5 10 All signals > 10 VEM Observer (1000)S > 100 VEM Observer (1000)S Figure 9.Left: comparison of S(1000)distributions for both reconstructions. The distribution can be fitted with the following power law: S(1000)Herald/VEM =1.154(S(1000)Observer/VEM)0.9904 (in black line). Right: relative difference ∆S(1000)/S(1000)Observer, where ∆S(1000)=S(1000)Herald −S(1000)Observer, for all events and also only those with S(1000)greater than 10 or 100 VEM. The corresponding means (standard deviations) of the distributions are 15.4% (10.8%), 11.2% (9.2%), and 10.9% (5.3%), respectively. the range of shower sizes. Note that as long as the correlation follows a power law, the energy calibration procedure summarized in section 8will exactly reconcile any differences in the shower size estimates of the two reconstructions. 6 Angular resolution The angular accuracy of the reconstruction of the SD events is mostly driven by the multiplicity of triggering stations and the precision of determination of the time at which the shower front arrived at each station. The latter is governed by an interplay between the number of particles, their time distribution in the shower front, and the area of the detectors. The small jitter of ∼10 ns in the GPS timing system [13] induces an angular uncertainty11 of less than ∼0.1◦. The uncertainty introduced by the 40 MHz sampling of the signals is of the same order of magnitude. Deriving the angular resolution of cosmic-ray experiments usually relies on the use of simulations where the reconstructed arrival direction is compared with the injected one. We also present such a simulation-based derivation here but additionally show results of measurement-driven studies of the angular resolution. The angular resolution is obtained by comparing two arrival directions ˆa1and ˆa2, which are either (a) reconstructed and true directions in the case of simulations, (b) two arrival directions reconstructed by the same procedure and thus with the same resolution, or (c) two arrival directions obtained by two different reconstruction methods, which may have different resolutions. The angular difference ηis obtained from sin η=|ˆa1׈a2|. For η1and in a normal approximation with one-dimensional variance σ2,ηfollows a distribution dN/dη=R(η;σ)for the case of (a) and dN/dη=R(η;√2σ)for the case of (b), where R(r;σ)=(r/σ2)exp(−r2/2σ2)is the Rayleigh distribution. We define the angular resolution (AR) as the angle at which the value 11Increasing the jitter in the GPS timing to 25 ns (100 ns) would induce an effect ∼0.2◦(∼1.5◦) for the smallest and <0.1◦(∼0.5◦) for the largest shower sizes. – 19 – 2020 JINST 15 P10021 of the cumulative distribution of ηreaches 68.3%, this being in turn equivalent to AR ≈1.52σor 1.52σ/√2for the two cases, respectively [30]. For the case (c) we assume that the two measurements σ1and σ2are uncorrelated and thus can be added in quadrature, i.e. σ2 tot =σ2 1+σ2 2. Below, three different approaches are explored to derive the angular resolution from measurements only, followed by a comparison of the results with a derivation from simulations.12 6.1 Derivation from measurements 6.1.1 Hybrid data In addition to the independent triggering systems of the FD and SD detectors, a hybrid trigger [31] has been designed requiring a coincidence of at least one SD station and an FD telescope. A subsample of these hybrid events can be fully reconstructed by both the FD hybrid reconstruction [8] and, independently, by the SD reconstruction. These events are used, among other things, for the calibration of the SD energy estimator with the calorimetric measurement performed by the FD [10]. From the direct comparison of the arrival directions of the two reconstructions, ˆaSD and ˆahyb, the angular resolution ARSD:hyb is extracted from the angular difference ηSD:hyb defined by sin ηSD:hyb =|ˆaSD ׈ahyb|. Given the essential independence of the SD and hybrid reconstructions, the SD angular resolution ARSD can be derived as AR2 SD =AR2 SD:hyb −AR2 hyb, where ARhyb is the angular resolution of the hybrid events only. With criteria to ensure the quality of the hybrid reconstruction, 29 344 events are selected. The details of the criteria applied can be found in [30,32]. Moreover, 1049 events are seen by at least two telescopes belonging to two different FD sites. For these stereo hybrid events, a separate13 hybrid reconstruction is performed for each FD site. Computing the angular difference ηhyb between these arrival directions ˆahyb 1and ˆahyb 2, the resolution of the hybrid reconstruction of this particular selection of stereo events is estimated to be ARhyb =(1.07 ±0.05)◦assuming that resolutions for ˆahyb 1and ˆahyb 2are the same.14 With ARhyb at hand, ARSD can be estimated as given above. The results are shown in figure 11 (squares) as a function of the zenith angle and the shower size. 6.1.2 Super-hexagon of multiplets Located in the denser sector of the SD array, 12 twins and 7 triplets of stations (two or three stations separated by ∼11 m) constitute the super-hexagon of the Observatory, as schematically depicted in figure 10 (red and green circles). The twins (or triplets) of the super-hexagon can be randomly divided to form two independent arrays and thereby enable two independent reconstructions of events that land in this region and trigger at least three twins. All other stations outside of the super-hexagon are not included in this specialized event reconstruction. Note that for showers of the same size, the multiplicity of stations used in this reconstruction can be, relative to the normal reconstruction, greatly reduced given the limited size of the super-hexagon. 12Results from the Observer framework are shown for these analyses and are compatible with those from Herald. 13Separate, but not completely independent since they share the same SD station used for the timing information. 14Note that stereo events have different geometries than standard hybrid (mono) events (the latter being on average closer to the telescopes) and therefore this number does not reflect the average resolution of the hybrid reconstruction which was estimated to be 0.5◦in [30]. – 20 – 2020 JINST 15 P10021 Figure 10. A map of the high-density sector of the SD array which is in the North-West corner of the Observatory (see figure 1). Regular stations of the 1500m grid are indicated with black markers. Stations of the 750 m grid are indicated with blue markers, where the stations forming three additional 1500 m sub-grids are indicated with triangular, square, and pentagonal markers. Twin and triplet stations in multiplets are indicated with red and green circles, respectively. Due to the small number of pairs available for this study, a selection on the position of the reconstructed core is applied. Only 913 reconstructed events,15 for which the impact point lies within a seed triangle constituted by twins only, are kept for the analysis. The estimate of the angular resolution ARSD is obtained from the distribution of the angular difference ηtw, defined as sin ηtw =|ˆatw 1׈atw 2|. The results of this procedure are shown in figure 11. 6.1.3 Sub-arrays The stations comprising the 750 m array can be split into four small sub-arrays with the usual 1500 m spacing, as illustrated in figure 10 (blue symbols). Respectively, 841, 516, and 392 events are independently reconstructed two, three, and four times, whereby requiring that the impact point of each reconstruction lies inside the corresponding seed triangle. For a given event with several successful reconstructions, the arrival directions are compared in pairs, i.e. by computing the angular difference ηsubi j from sin ηsubi j =|ˆasub i׈asub j|. Here, we assume that all ηsubi j are independent, obtaining 4741 angles for the calculation of the estimate of angular resolution ARSD. The results are reported in figure 11 (circles). 6.2 Estimation using simulations Using simulations of extensive air-showers, the angular resolution is obtained as a function of zenith angle θand the shower size S(1000). Showers initiated by a proton or an iron primary and 15Requirement of having the same number of stations in each twin set reduces the number of events to 301, nevertheless, the AR results remain statistically compatible. – 21 – 2020 JINST 15 P10021 θ 2 sin 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 ° Angular Resolution / 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 Twin Hybrid Sub-array Proton Iron QGSJet-II.04 EPOS-LHC θsec 1 1.2 1.4 1.6 1.8 2 (1000) / VEM)Slg( 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 ° Angular Resolution / 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 Twin Hybrid Sub-array Proton Iron QGSJet-II.04 EPOS-LHC ) / eV)°=38θ(Elg( 18.5 19 19.5 20 Figure 11. Angular resolution of the reconstructed arrival direction as derived from a study of the hybrid events (filled black squares), a study of events with at least three triggered twins (filled black circles), and a study of three sub-arrays (open circles). The lines report the results from the study with simulations produced with the hadronic model QGSJet-II.04 (full lines) and EPOS-LHC (dashed lines) for iron (dark gray lines) and proton (light gray lines) primaries. The angular resolution of the reconstructed arrival direction is shown as a function of zenith angle (left) and the shower size (right). developing according to the EPOS-LHC [33] or QGSJet-II.04 [34] model of hadronic interactions are simulated with energies between 1018.5and 1020 eV and zenith angles between 0◦and 60◦. An SD simulation and event reconstruction is performed 10 times for each shower simulation, where the impact position on the SD array is randomly chosen according to a uniform probability distribution across the complete array. The reconstructed arrival directions ˆarec are compared with the true simulated axis ˆaof the shower by computing the angular difference ηfrom sin η=|ˆa׈arec|and estimating the AR from its distribution. For plotting purposes, the results are empirically approximated to a good degree as a second-order polynomial in sin2θand as an exponential function in lg(S(1000)/VEM). The results are reported in figure 11 (lines and bands). 6.3 Comparison of results The AR, as derived from both measured and simulated data, is shown to improve with increasing zenith angle and shower size. The improvement for inclined events is attributed to the increase in the number of stations participating in an event due to the foreshortening of the array. The slight discrepancies between the AR obtained from the measured and simulated data can be explained by limitations in the reconstruction of measurements in these specialized studies; considering that only a small number of SD stations were available for the twin and sub-array studies, the typical multiplicities of stations in events decreased and with them, the angular accuracy of the performed reconstructions. Finally, computing the SD angular resolution from events reconstructed by both the FD and the SD in a data-driven way is limited by the knowledge of the angular resolution of the hybrid reconstruction ARhyb. There are fewer high-quality events measured by the FD due to its limited duty cycle and the selection criteria applied. Moreover, in order to derive ARhyb and then ARSD, we distinguish between the FD reconstructions where the telescope was closer or further – 22 – 2020 JINST 15 P10021 from the axis of the shower. The geometrical reconstruction of the latter is thus expected to be worse, which would lead to an overestimation of the accuracy of the SD. It is known that there are some deficiencies in the simulations of air showers, particularly with respect to the magnitude of the muonic component [35]. Additionally, while simulations of the detector response have been thoroughly validated [36], it is still possible that some experimental effects are not reproduced. Performing comparisons of resolution estimates between simulated and measured data in terms of shower size mitigates the impact of the shortcomings of the simulations to the first-order. The actual angular resolution of the SD is expected to lie somewhere between the measured data points and the simulated lines. The angular resolution improves with both increasing zenith angle and shower size but is always better than 1.4◦and even approaches 0.7◦for the largest and most inclined showers. It is also important to note that the differences between the results obtained from the Herald and Observer reconstructions are smaller than the angular resolution of the SD. It is also worth mentioning that the angular differences observed in figure 6-right are primarily due to the correction of the signal asymmetry present in the Herald reconstruction only. These asymmetry corrections then induce a shift of the impact point of the shower core, as observed in figure 8-right, which is, in turn, translated into the angular differences observed. The resolution of the impact point depends on the intrinsic properties of the shower and varies from ∼100 m at the lowest energies to ∼50 m at the highest energies. The core resolution (measured in the ground plane) worsens with increasing inclination, which can be attributed to the projection effect. 7 Uncertainties in S(1000) The uncertainty of the shower size estimator S(1000)consists of statistical and systematic contributions. While the statistical uncertainties of the reconstructed shower size, σstat(S(1000)), are directly related to the number of triggered stations and the uncertainties in their signals, the systematic uncertainties, σsyst(S(1000)), arise from the lack of knowledge of the true shape of the LDF. The uncertainties of S(1000)are first estimated through propagation of statistical and systematic errors in the fit of the LDF. These estimations are complemented by two data-driven methods for the lower shower-size regime, where sufficient data are available, and a comparison with uncertainty estimates derived from simulations. 7.1 Fit uncertainties and model-dependent systematic errors The statistical uncertainties in S(1000)are directly estimated during the fitting procedure. The derivation of the systematic uncertainties requires a deeper study of the slope parameter βfrom eqs. (5.6) and (5.7). As a first step, we use the same subset of events already used in the determination of βin section 5.2.1, i.e. events for which βcan be reliably fitted. The resulting standard deviation σβof the difference between the fixed and free βis parametrized as a function of S(1000). In a second step, the systematic uncertainties are computed by propagating σβ(S(1000))into the shower size estimator for all events. This approach is applied to the full data set of events recorded by the SD, while using the quality cuts described in the previous sections. The average systematic uncertainties and statistical errors are reported in figure 12 as a function of lg(S(1000)/VEM)(left) and as a function of sin2θ – 23 – 2020 JINST 15 P10021 [10] Pierre Auger collaboration, A measurement of the cosmic ray energy spectrum above 2.5×1018 eV using the Pierre Auger Observatory,Phys. Rev. D 102 (2020) 062005 [arXiv:2008.06486]. [11] Pierre Auger collaboration, Reconstruction of Inclined Air Showers Detected with the Pierre Auger Observatory,JCAP 08 (2014) 019 [arXiv:1407.3214]. [12] S. Argiro et al., The Offline Software Framework of the Pierre Auger Observatory,Nucl. Instrum. Meth. A 580 (2007) 1485 [arXiv:0707.1652]. [13] Pierre Auger collaboration, Timing calibration and synchronization of surface and fluorescence detectors of the Pierre Auger Observatory, in 29th International Cosmic Ray Conference, Pune India (2005). [14] Pierre Auger collaboration, Trigger and Aperture of the Surface Detector Array of the Pierre Auger Observatory,Nucl. Instrum. Meth. A 613 (2010) 29 [arXiv:1111.6764]. [15] Pierre Auger collaboration, Large-scale cosmic-ray anisotropies above 4 EeV measured by the Pierre Auger Observatory,Astrophys. J. 868 (2018) 4 [arXiv:1808.03579]. [16] Pierre Auger collaboration, Cosmic-ray anisotropies in right ascension measured by the Pierre Auger Observatory,Astrophys. J. 891 (2020) 142 [arXiv:2002.06172]. [17] Pierre Auger collaboration, The Pierre Auger Observatory Scaler Mode for the Study of Solar Activity Modulation of Galactic Cosmic Rays,2011 JINST 6P01003. [18] Pierre Auger collaboration, Calibration of the surface array of the Pierre Auger Observatory,Nucl. Instrum. Meth. A 568 (2006) 839. [19] Pierre Auger collaboration, The Pierre Auger Observatory: Contributions to the 33rd International Cosmic Ray Conference (ICRC 2013), in 33rd International Cosmic Ray Conference, 7, 2013 [arXiv:1307.5059]. [20] Pierre Auger collaboration, A model for the time uncertainty measurements in the Auger surface detector array,Astropart. Phys. 28 (2008) 523 [arXiv:0705.1856]. [21] Pierre Auger collaboration, The accuracy of signal measurement with the water Cherenkov detectors of the Pierre Auger Observatory,Nucl. Instrum. Meth. A 578 (2007) 180. [22] J. Linsley and L. Scarsi, Arrival times of air shower particles at large distances from the axis,Phys. Rev. 128 (1962) 2384. [23] F. James, Minuit, function minimization and error analysis, CERN-D-506, CERN-D506 (1998). [24] D. Newton, J. Knapp and A.A. Watson, The Optimum Distance at which to Determine the Size of a Giant Air Shower,Astropart. Phys. 26 (2007) 414 [astro-ph/0608118]. [25] M. Nagano and A.A. Watson, Observations and implications of the ultrahigh-energy cosmic rays, Rev. Mod. Phys. 72 (2000) 689. [26] K. Kamata and J. Nishimura, The lateral and the angular structure functions of electron showers, Prog. Theor. Phys. Suppl. 6(1958) 93. [27] K. Greisen, The extensive air showers,Prog. Cosmic Ray Phys. 3(1956) 1. [28] K. Greisen, Cosmic ray showers,Ann. Rev. Nucl. Part. Sci. 10 (1960) 63. [29] A.M. Hillas, Measurement of primary energy in air showers in the presence of fluctuations, in Proceedings of 12th International Cosmic Ray Conference, Hobart Australia (1971), pg. 1001. [30] Pierre Auger collaboration, Angular resolution of the Pierre Auger Observatory, in 29th International Cosmic Ray Conference, Pune India (2005). [31] Pierre Auger collaboration, The Exposure of the Hybrid Detector of the Pierre Auger Observatory, Astropart. Phys. 34 (2011) 368 [arXiv:1010.6162]. – 30 – 2020 JINST 15 P10021 [32] Pierre Auger collaboration, Hybrid Performance of the Pierre Auger Observatory, in 30th International Cosmic Ray Conference, Merida Mexico (2007), pg. 425 [arXiv:0706.1105]. [33] T. Pierog, I. Karpenko, J.M. Katzy, E. Yatsenko and K. Werner, EPOS LHC: Test of collective hadronization with data measured at the CERN Large Hadron Collider,Phys. Rev. C 92 (2015) 034906 [arXiv:1306.0121]. [34] S. Ostapchenko, Monte Carlo treatment of hadronic interactions in enhanced Pomeron scheme: I. QGSJET-II model,Phys. Rev. D 83 (2011) 014018 [arXiv:1010.1869]. [35] Pierre Auger collaboration, Testing Hadronic Interactions at Ultrahigh Energies with Air Showers Measured by the Pierre Auger Observatory,Phys. Rev. Lett. 117 (2016) 192001 [arXiv:1610.08509]. [36] Pierre Auger collaboration, Studies on the response of a water-Cherenkov detector of the Pierre Auger Observatory to atmospheric muons using an RPC hodoscope,2020 JINST 15 P09002 [arXiv:2007.04139]. [37] Pierre Auger collaboration, Impact of Atmospheric Effects on the Energy Reconstruction of Air Showers Observed by the Surface Detectors of the Pierre Auger Observatory,2017 JINST 12 P02006 [arXiv:1702.02835]. [38] Pierre Auger collaboration, The effect of the geomagnetic field on cosmic ray energy estimates and large scale anisotropy searches on data from the Pierre Auger Observatory,JCAP 11 (2011) 022 [arXiv:1111.7122]. [39] T.K. Gaisser and A.M. Hillas, Reliability of the method of constant intensity cuts for reconstructing the average development of vertical showers, in Proceedings of 15th International Cosmic Ray Conference, Plovdiv Bulgaria (1977), pg. 353. [40] H.P. Dembinski, B. Kégl, I.C. Mariş, M. Roth and D. Veberič, A likelihood method to cross-calibrate air-shower detectors,Astropart. Phys. 73 (2016) 44 [arXiv:1503.09027]. [41] Pierre Auger collaboration, The dynamic range of the AugerPrime Surface Detector: technical solution and physics reach,PoS(ICRC2017)397. [42] Pierre Auger collaboration, An Indication of anisotropy in arrival directions of ultra-high-energy cosmic rays through comparison to the flux pattern of extragalactic gamma-ray sources,Astrophys. J. Lett. 853 (2018) L29 [arXiv:1801.06160]. [43] Pierre Auger collaboration, Multi-Messenger Physics with the Pierre Auger Observatory,Front. Astron. Space Sci. 6(2019) 24 [arXiv:1904.11918]. [44] Pierre Auger collaboration, Evidence for a mixed mass composition at the ‘ankle’ in the cosmic-ray spectrum,Phys. Lett. B 762 (2016) 288 [arXiv:1609.08567]. [45] Pierre Auger collaboration, Inferences on mass composition and tests of hadronic interactions from 0.3 to 100 EeV using the water-Cherenkov detectors of the Pierre Auger Observatory,Phys. Rev. D 96 (2017) 122003 [arXiv:1710.07249]. [46] Pierre Auger collaboration, Features of the energy spectrum of cosmic rays above 2.5×1018 eV using the Pierre Auger Observatory,Phys. Rev. Lett. 125 (2020) 121106. [47] Pierre Auger collaboration, Measurement of the Cosmic Ray Flux near the Second Knee with the Pierre Auger Observatory,PoS(ICRC2019)225. [48] Pierre Auger collaboration, The Pierre Auger Observatory Upgrade — Preliminary Design Report, arXiv:1604.03637. [49] Pierre Auger collaboration, Highlights from the Pierre Auger Observatory (ICRC2019), PoS(ICRC2019)004 [arXiv:1909.10791]. – 31 – 2020 JINST 15 P10021 The Pierre Auger collaboration A. Aab75, P. Abreu67, M. Aglietta50,49, J.M. Albury12, I. Allekotte1, A. Almela8,11, J. Alvarez Castillo63, J. Alvarez-Muñiz74, R. Alves Batista75, G.A. Anastasi58,49, L. Anchordoqui82, B. Andrada8, S. Andringa67, C. Aramo47, P.R. Araújo Ferreira39, H. Asorey8, P. Assis67, G. Avila9,10, A.M. Badescu70, A. Bakalova30, A. Balaceanu68, F. Barbato56,47, R.J. Barreira Luz67, K.H. Becker35, J.A. Bellido12, C. Berat34, M.E. Bertaina58,49, X. Bertou1, P.L. Biermannb, P. Billoir33, T. Bister39, J. Biteau32, A. Blanco67, J. Blazek30, C. Bleve34, M. Boháčová30, D. Boncioli53,43, C. Bonifazi24, L. Bonneau Arbeletche19, N. Borodai64, A.M. Botti8, J. Bracke, T. Bretz39, A. Bridgeman37, F.L. Briechle39, P. Buchholz41, A. Bueno73, S. Buitink14, M. Buscemi54,44, K.S. Caballero-Mora62, L. Caccianiga55,46, L. Calcagni4, A. Cancio11,8, F. Canfora75,77, I. Caracas35, J.M. Carceller73, R. Caruso54,44, A. Castellina50,49, F. Catalani17, G. Cataldi45, L. Cazon67, M. Cerda9, J.A. Chinellato20, K. Choi74, J. Chudoba30, L. Chytka31, R.W. Clay12, A.C. Cobos Cerutti7, R. Colalillo56,47, A. Coleman88, M.R. Coluccia52,45, R. Conceição67, A. Condorelli42,43, G. Consolati46,51, F. Contreras9,10, F. Convenga52,45, C.E. Covault80,h, S. Dasso5,3, K. Daumiller37, B.R. Dawson12, J.A. Day12, R.M. de Almeida26, J. de Jesús8,37, S.J. de Jong75,77, G. De Mauro75,77, J.R.T. de Mello Neto24,25, I. De Mitri42,43, J. de Oliveira26, D. de Oliveira Franco20, V. de Souza18, E. De Vito52,45, J. Debatin36, M. del Río10, O. Deligny32, N. Dhital64, A. Di Matteo49, M.L. Díaz Castro20, C. Dobrigkeit20, J.C. D’Olivo63, Q. Dorosti41, R.C. dos Anjos23, M.T. Dova4, J. Ebr30, R. Engel36,37, I. Epicoco52,45, M. Erdmann39, C.O. Escobarc, A. Etchegoyen8,11, H. Falcke75,78,77, J. Farmer87, G. Farrar85, A.C. Fauth20, N. Fazzinic, F. Feldbusch38, F. Fenu58,49, B. Fick84, J.M. Figueira8, A. Filipčič72,71, T. Fodran75, M.M. Freire6, T. Fujii87,f, A. Fuster8,11, C. Galea75, C. Galelli55,46, B. García7, A.L. Garcia Vegas39, H. Gemmeke38, F. Gesualdi8,37, A. Gherghel-Lascu68, P.L. Ghia32, U. Giaccari75, M. Giammarchi46, M. Giller65, J. Glombitza39, F. Gobbi9, F. Gollan8, G. Golup1, M. Gómez Berisso1, P.F. Gómez Vitale9,10, J.P. Gongora9, N. González8, I. Goos1,37, D. Góra64, A. Gorgi50,49, M. Gottowik35, T.D. Grubb12, F. Guarino56,47, G.P. Guedes21, E. Guido49,58, S. Hahn37,8, R. Halliday80, M.R. Hampel8, P. Hansen4, D. Harari1, V.M. Harvey12, A. Haungs37, T. Hebbeker39, D. Heck37, G.C. Hill12, C. Hojvatc, J.R. Hörandel75,77, P. Horvath31, M. Hrabovský31, T. Huege37,14, J. Hulsman8,37, A. Insolia54,44, P.G. Isar69, J.A. Johnsen81, J. Jurysek30, A. Kääpä35, K.H. Kampert35, B. Keilhauer37, J. Kemp39, H.O. Klages37, M. Kleifges38, J. Kleinfeller9, M. Köpke36, G. Kukec Mezek71, B.L. Lago16, D. LaHurd80, R.G. Lang18, M.A. Leigui de Oliveira22, V. Lenok37, A. Letessier-Selvon33, I. Lhenry-Yvon32, D. Lo Presti54,44, L. Lopes67, R. López59, R. Lorek80, Q. Luce36, A. Lucero8, A. Machado Payeras20, M. Malacari87, G. Mancarella52,45, D. Mandat30, B.C. Manning12, J. Manshanden40, P. Mantschc, S. Marafico32, A.G. Mariazzi4, I.C. Mariş13, G. Marsella52,45, D. Martello52,45, H. Martinez18, O. Martínez Bravo59, M. Mastrodicasa53,43, H.J. Mathes37, J. Matthews83, G. Matthiae57,48, E. Mayotte35, P.O. Mazurc, G. Medina-Tanco63, D. Melo8, A. Menshikov38, K.-D. Merenda81, S. Michal31, M.I. Micheletti6, L. Miramonti55,46, D. Mockler13, S. Mollerach1, F. Montanet34, C. Morello50,49, M. Mostafá86, A.L. Müller8,37, M.A. Muller20,d,24, K. Mulrey14, R. Mussa49, M. Muzio85, W.M. Namasaka35, L. Nellen63, M. Niculescu-Oglinzanu68, M. Niechciol41, D. Nitz84,g, D. Nosek29, V. Novotny29, L. Nožka31, A Nucita52,45, L.A. Núñez28, M. Palatka30, J. Pallotta2, M.P. Panetta52,45, P. Papenbreer35, G. Parente74, A. Parra59, M. Pech30, F. Pedreira74, J. Pe¸kala64, R. Pelayo61, J. Peña-Rodriguez28, J. Perez Armand19, M. Perlin8,37, L. Perrone52,45, C. Peters39, S. Petrera42,43, T. Pierog37, M. Pimenta67, V. Pirronello54,44, M. Platino8, B. Pont75, M. Pothast77,75, P. Privitera87, M. Prouza30, A. Puyleart84, S. Querchfeld35, J. Rautenberg35, D. Ravignani8, M. Reininghaus37,8, J. Ridky30, F. Riehn67, M. Risse41, P. Ristori2, V. Rizi53,43, W. Rodrigues de Carvalho19, J. Rodriguez Rojo9, M.J. Roncoroni8, M. Roth37, E. Roulet1, A.C. Rovero5, P. Ruehl41, S.J. Saffi12, A. Saftoiu68, F. Salamida53,43, H. Salazar59, G. Salina48, J.D. Sanabria Gomez28, F. Sánchez8, E.M. Santos19, E. Santos30, F. Sarazin81, R. Sarmento67, C. Sarmiento-Cano8, R. Sato9, P. Savina52,45,32, C. Schäfer37, V. Scherini45, H. Schieler37, M. Schimassek36,8, M. Schimp35, F. Schlüter37,8, D. Schmidt36, O. Scholten76,14, P. Schovánek30, – 32 – 2020 JINST 15 P10021 F.G. Schröder88,37, S. Schröder35, A. Schulz37, S.J. Sciutto4, M. Scornavacche8,37, R.C. Shellard15, G. Sigl40, G. Silli8,37, O. Sima68,i, R. Šmída87, P. Sommers86, J.F. Soriano82, J. Souchard34, R. Squartini9, M. Stadelmaier37,8, D. Stanca68, S. Stanič71, J. Stasielak64, P. Stassi34, A. Streich36,8, M. Suárez-Durán28, T. Sudholz12, T. Suomijärvi32, A.D. Supanitsky8, J. Šupík31, Z. Szadkowski66, A. Taboada36, A. Tapia27, C. Timmermans77,75, O. Tkachenko37, P. Tobiska30, C.J. Todero Peixoto17, B. Tomé67, G. Torralba Elipe74, A. Travaini9, P. Travnicek30, C. Trimarelli53,43, M. Trini71, M. Tueros4, R. Ulrich37, M. Unger37, M. Urban39, L. Vaclavek31, M. Vacula31, J.F. Valdés Galicia63, I. Valiño42,43, L. Valore56,47, A. van Vliet75, E. Varela59, B. Vargas Cárdenas63, A. Vásquez-Ramírez28, D. Veberič37, C. Ventura25, I.D. Vergara Quispe4, V. Verzi48, J. Vicha30, L. Villaseñor59, J. Vink79, S. Vorobiov71, H. Wahlberg4, A.A. Watsona, M. Weber38, A. Weindl37, L. Wiencke81, H. Wilczyński64, T. Winchen14, M. Wirtz39, D. Wittkowski35, B. Wundheiler8, A. Yushkov30, O. Zapparrata13, E. Zas74, D. Zavrtanik71,72, M. Zavrtanik72,71, L. Zehrer71, A. Zepeda60, M. Ziolkowski41, F. Zuccarello54,44 1Centro Atómico Bariloche and Instituto Balseiro (CNEA-UNCuyo-CONICET), San Carlos de Bariloche, Argentina 2Centro de Investigaciones en Láseres y Aplicaciones, CITEDEF and CONICET, Villa Martelli, Argentina 3Departamento de Física and Departamento de Ciencias de la Atmósfera y los Océanos, FCEyN, Universidad de Buenos Aires and CONICET, Buenos Aires, Argentina 4IFLP, Universidad Nacional de La Plata and CONICET, La Plata, Argentina 5Instituto de Astronomía y Física del Espacio (IAFE, CONICET-UBA), Buenos Aires, Argentina 6Instituto de Física de Rosario (IFIR) – CONICET/U.N.R. and Facultad de Ciencias Bioquímicas y Farmacéuticas U.N.R., Rosario, Argentina 7Instituto de Tecnologías en Detección y Astropartículas (CNEA, CONICET, UNSAM), and Universidad Tecnológica Nacional – Facultad Regional Mendoza (CONICET/CNEA), Mendoza, Argentina 8Instituto de Tecnologías en Detección y Astropartículas (CNEA, CONICET, UNSAM), Buenos Aires, Argentina 9Observatorio Pierre Auger, Malargüe, Argentina 10 Observatorio Pierre Auger and Comisión Nacional de Energía Atómica, Malargüe, Argentina 11 Universidad Tecnológica Nacional – Facultad Regional Buenos Aires, Buenos Aires, Argentina 12 University of Adelaide, Adelaide, S.A., Australia 13 Université Libre de Bruxelles (ULB), Brussels, Belgium 14 Vrije Universiteit Brussels, Brussels, Belgium 15 Centro Brasileiro de Pesquisas Fisicas, Rio de Janeiro, RJ, Brazil 16 Centro Federal de Educação Tecnológica Celso Suckow da Fonseca, Nova Friburgo, Brazil 17 Universidade de São Paulo, Escola de Engenharia de Lorena, Lorena, SP, Brazil 18 Universidade de São Paulo, Instituto de Física de São Carlos, São Carlos, SP, Brazil 19 Universidade de São Paulo, Instituto de Física, São Paulo, SP, Brazil 20 Universidade Estadual de Campinas, IFGW, Campinas, SP, Brazil 21 Universidade Estadual de Feira de Santana, Feira de Santana, Brazil 22 Universidade Federal do ABC, Santo André, SP, Brazil 23 Universidade Federal do Paraná, Setor Palotina, Palotina, Brazil 24 Universidade Federal do Rio de Janeiro, Instituto de Física, Rio de Janeiro, RJ, Brazil 25 Universidade Federal do Rio de Janeiro (UFRJ), Observatório do Valongo, Rio de Janeiro, RJ, Brazil 26 Universidade Federal Fluminense, EEIMVR, Volta Redonda, RJ, Brazil 27 Universidad de Medellín, Medellín, Colombia 28 Universidad Industrial de Santander, Bucaramanga, Colombia 29 Charles University, Faculty of Mathematics and Physics, Institute of Particle and Nuclear Physics, Prague, Czech Republic 30 Institute of Physics of the Czech Academy of Sciences, Prague, Czech Republic 31 Palacky University, RCPTM, Olomouc, Czech Republic 32 Université Paris-Saclay, CNRS/IN2P3, IJCLab, Orsay, France 33 Laboratoire de Physique Nucléaire et de Hautes Energies (LPNHE), Universités Paris 6 et Paris 7, CNRS-IN2P3, Paris, France – 33 – 2020 JINST 15 P10021 34 Univ. Grenoble Alpes, CNRS, Grenoble Institute of Engineering Univ. Grenoble Alpes, LPSC-IN2P3, 38000 Grenoble, France 35 Bergische Universität Wuppertal, Department of Physics, Wuppertal, Germany 36 Karlsruhe Institute of Technology, Institute for Experimental Particle Physics (ETP), Karlsruhe, Germany 37 Karlsruhe Institute of Technology, Institut für Kernphysik, Karlsruhe, Germany 38 Karlsruhe Institute of Technology, Institut für Prozessdatenverarbeitung und Elektronik, Karlsruhe, Germany 39 RWTH Aachen University, III. Physikalisches Institut A, Aachen, Germany 40 Universität Hamburg, II. Institut für Theoretische Physik, Hamburg, Germany 41 Universität Siegen, Fachbereich 7 Physik – Experimentelle Teilchenphysik, Siegen, Germany 42 Gran Sasso Science Institute, L’Aquila, Italy 43 INFN Laboratori Nazionali del Gran Sasso, Assergi (L’Aquila), Italy 44 INFN, Sezione di Catania, Catania, Italy 45 INFN, Sezione di Lecce, Lecce, Italy 46 INFN, Sezione di Milano, Milano, Italy 47 INFN, Sezione di Napoli, Napoli, Italy 48 INFN, Sezione di Roma “Tor Vergata”, Roma, Italy 49 INFN, Sezione di Torino, Torino, Italy 50 Osservatorio Astrofisico di Torino (INAF), Torino, Italy 51 Politecnico di Milano, Dipartimento di Scienze e Tecnologie Aerospaziali , Milano, Italy 52 Università del Salento, Dipartimento di Matematica e Fisica “E. De Giorgi”, Lecce, Italy 53 Università dell’Aquila, Dipartimento di Scienze Fisiche e Chimiche, L’Aquila, Italy 54 Università di Catania, Dipartimento di Fisica e Astronomia, Catania, Italy 55 Università di Milano, Dipartimento di Fisica, Milano, Italy 56 Università di Napoli “Federico II”, Dipartimento di Fisica “Ettore Pancini”, Napoli, Italy 57 Università di Roma “Tor Vergata”, Dipartimento di Fisica, Roma, Italy 58 Università Torino, Dipartimento di Fisica, Torino, Italy 59 Benemérita Universidad Autónoma de Puebla, Puebla, México 60 Centro de Investigación y de Estudios Avanzados del IPN (CINVESTAV), México, D.F., México 61 Unidad Profesional Interdisciplinaria en Ingeniería y Tecnologías Avanzadas del Instituto Politécnico Nacional (UPIITA-IPN), México, D.F., México 62 Universidad Autónoma de Chiapas, Tuxtla Gutiérrez, Chiapas, México 63 Universidad Nacional Autónoma de México, México, D.F., México 64 Institute of Nuclear Physics PAN, Krakow, Poland 65 University of Łódź, Faculty of Astrophysics, Łódź, Poland 66 University of Łódź, Faculty of High-Energy Astrophysics,Łódź, Poland 67 Laboratório de Instrumentação e Física Experimental de Partículas – LIP and Instituto Superior Técnico – IST, Universidade de Lisboa – UL, Lisboa, Portugal 68 “Horia Hulubei” National Institute for Physics and Nuclear Engineering, Bucharest-Magurele, Romania 69 Institute of Space Science, Bucharest-Magurele, Romania 70 University Politehnica of Bucharest, Bucharest, Romania 71 Center for Astrophysics and Cosmology (CAC), University of Nova Gorica, Nova Gorica, Slovenia 72 Experimental Particle Physics Department, J. Stefan Institute, Ljubljana, Slovenia 73 Universidad de Granada and C.A.F.P.E., Granada, Spain 74 Instituto Galego de Física de Altas Enerxías (IGFAE), Universidade de Santiago de Compostela, Santiago de Compostela, Spain 75 IMAPP, Radboud University Nijmegen, Nijmegen, The Netherlands 76 KVI – Center for Advanced Radiation Technology, University of Groningen, Groningen, The Netherlands 77 Nationaal Instituut voor Kernfysica en Hoge Energie Fysica (NIKHEF), Science Park, Amsterdam, The Netherlands 78 Stichting Astronomisch Onderzoek in Nederland (ASTRON), Dwingeloo, The Netherlands 79 Universiteit van Amsterdam, Faculty of Science, Amsterdam, The Netherlands 80 Case Western Reserve University, Cleveland, OH, U.S.A. 81 Colorado School of Mines, Golden, CO, U.S.A. – 34 – 2020 JINST 15 P10021 82 Department of Physics and Astronomy, Lehman College, City University of New York, Bronx, NY, U.S.A. 83 Louisiana State University, Baton Rouge, LA, U.S.A. 84 Michigan Technological University, Houghton, MI, U.S.A. 85 New York University, New York, NY, U.S.A. 86 Pennsylvania State University, University Park, PA, U.S.A. 87 University of Chicago, Enrico Fermi Institute, Chicago, IL, U.S.A. 88 University of Delaware, Department of Physics and Astronomy, Bartol Research Institute, Newark, DE, U.S.A. aSchool of Physics and Astronomy, University of Leeds, Leeds, United Kingdom bMax-Planck-Institut für Radioastronomie, Bonn, Germany cFermi National Accelerator Laboratory, U.S.A. dalso at Universidade Federal de Alfenas, Poços de Caldas, Brazil eColorado State University, Fort Collins, CO, U.S.A. fnow at Hakubi Center for Advanced Research and Graduate School of Science, Kyoto University, Kyoto, Japan galso at Karlsruhe Institute of Technology, Karlsruhe, Germany halso at Radboud Universtiy Nijmegen, Nijmegen, The Netherlands – 35 –