scieee AI-readable full text Open interactive document viewer

Least Angle Regression for early-stage identification of earthquake-induced damage in a monumental masonry palace: Palazzo dei Consoli

García Macías, Enrique,Ubertini, Filippo

Full text

Least Angle Regression for early-stage identification of earthquake-induced damage in a monumental masonry palace: Palazzo dei Consoli Enrique Garc´ ıa-Mac´ ıasa,b,∗, Filippo Ubertinia aDepartment of Civil and Environmental Engineering, University of Perugia. Via G. Duranti, 93 - 06125 Perugia, Italy. bDepartment of Structural Mechanics and Hydraulic Engineering, University of Granada, Av. Fuentenueva sn, 18002 Granada, Spain. Abstract This paper presents a novel methodology for earthquake-induced damage identification of historical constructions through sparse mutivariate regression. The proposed methodology comprises a first data cleansing stage using the minimum covariance determinant (MCD) method to mitigate the adverse effects related to the existence of outliers in the training feature dataset. Afterwards, a sparse multiple linear regression model (SMLR) is trained using the least-angle regression (LAR) model to eliminate the influence of environmental effects upon the selected features set. The proposed SMLR model allows to identify the optimal set of predictors in a fully automated way, minimizing the need for expert judgement in the process. The effectiveness of the proposed approach is demonstrated with an application case study of a monumental masonry palace, the Consoli Palace in Gubbio (Italy). The palace has been monitored with an aggregated static/dynamic/environmental SHM system since July 14th 2020. A recent seismic sequence of small intensity hit the palace on May 15th 2021 with a main earthquake of magnitude Mw 4.0. The epicenters of the main seismic event and the following aftershocks were located at a distance of 2-3 km far from the palace, making this case study a prominent example of a monumental construction subjected to near-field ground motion. The presented results demonstrate that a new damage condition arises in the Consoli Palace after the seismic sequence, although its severity remains at an early stage not detectable by visual inspections. Keywords: Earthquake, Control charts, Damage detection, Historic buildings, Operational Modal Analysis, Structural health monitoring, Statistical Pattern Recognition. 1. Introduction1 Cultural heritage buildings constitute especially sensitive assets in the built stock due to their strategic role in2 the tourism industry and their invaluable historical and social value. Indeed, the turnover generated in industries3 closely linked to cultural heritage represented 10.3% of the European Union GPD in 2018 [1] and, despite the4 Covid-19 recession, experts forecast the recovery to pre-pandemic levels by 2024 [2]. The maintenance of historic5 constructions is often troublesome due to their complex distribution of volumes and heterogenity, uncertainties in6 ∗Corresponding author. Department of Civil and Environmental Engineering, University of Perugia. Via G. Duranti, 93 - 06125 Perugia, Italy. phone: +39 075 585 3908; fax: +39 075 585 3897 Email addresses: [email protected] (Enrique Garc´ ıa-Mac´ ıas), [email protected] (Filippo Ubertini) Preprint submitted to Engineering Structures January 20, 2022 their materials and inner structure, as well as the presence of historical series of damage with uncertain origin and7 extension. Masonry historical buildings are particularly vulnerable to seismic actions due to their often low tensile8 strength, massive weight, poor connection between vertical and horizontal structural elements, and irregularities9 in plan and height [3, 4]. An example of this is the 2016-2017 Central Italy seismic sequence which caused com-10 plete destruction or heavy damage of important historical centres in four regions along the Apennines (Abruzzo,11 Lazio, Marche and Umbria) and 300 fatalities [5]. Apart from their vulnerability to natural material degradation12 and seismic actions, heritage structures must also face new challenges including increasing usage demands and13 visit flows, growing presence of corrosive pollutants, and climate change-induced more frequent utmost weather14 events [6]. Examples of sudden collapses such as the civic tower of Pavia in 1989 [7] and the Albiano Magra15 bridge in 2020 have evidenced the large risks associated with ageing degradation and poor maintenance. In this16 light, large financial efforts have been dedicated to R&D actions in the field of SHM of historical constructions17 since the seventies, although their extensive application to engineering practice remains marginal [8, 9]. Such a18 slow technological transfer is in part due to the lack of performance validation of damage identification techniques19 on full-scale structures under real operating conditions and, consequently, uncertain return on investments [10].20 The management of long-term SHM systems falls within the pattern recognition paradigm formalized by Far-21 rar et al. [11]. The basic idea is to establish relationships between damage states or classes and certain features22 extracted from the monitoring data by seeking for patterns in the response of the monitored structure. Within23 this paradigm, the stages of data cleansing, normalization, and damage classification are pivotal elements to attain24 effective damage identification. Data cleansing regards the process of filtering out uninformative or corrupted25 data (outliers), while data normalization relates the ability of separating the variability in the selected features26 induced by damage from those caused by environmental/operational conditions (EOC). Finally, damage classifi-27 cation concerns the inference of mappings between the extracted features and diagnosis classes. In the realm of28 historic structures, there is broad consensus on the importance of implementing aggregated SHM systems exploit-29 ing features extracted from diverse sensing technologies to so achieve a comprehensive damage identification. As30 a global damage identification technique, ambient vibration-based monitoring has become particularly widespread31 owing to their non-destructive nature and minimum invasiveness upon the normal fruition of the structure under32 study [12]. These techniques exploit experimentally identified modal signatures (i.e. natural frequencies, mode33 shapes, and damping ratios) as damage sensitive features (DSFs) [13, 14]. Nonetheless, their ability to detect local34 defects is rather limited (e.g. freezing/thawing cycles, chemical attack, corrosion) [15], whereby it is convenient to35 complement them with static monitoring such as the assessment of crack amplitudes, displacements or tilts [16].36 The management of such aggregated long-term systems requires to handle large heterogeneous databases, framing37 the SHM problem into a Big Data and Machine Learning context [17–19]. While the statistical pattern recogni-38 tion paradigm of SHM is formulated in broad general terms, the diverse steps involved in the process are generally39 highly case dependent.40 The effectiveness of the damage identification is critically determined by the quality of the removal of EOC41 2 in the data normalisation stage. There are numerous works in the literature reporting the striking influence of42 manifold environmental/operational factors (e.g. temperature, humidity, traffic, wind) upon the dynamic/static43 response of civil engineering structures. Such factors provoke variations in the boundary conditions and the44 stiffness/mass properties of structures [20], resulting in fluctuations in their behaviour with different space- and45 time-scales. Among the extensive literature works reporting on these effects, it is worth noting the one by Zonno et46 al. [21], who investigated during one year the correlations between environmental factors and the modal properties47 of an adobe historic building, the San Pedro Apostol church in Peru. Their results reported daily and seasonal48 variations in the resonant frequencies of up to 1.5% and 8%, respectively, and identified the variations in the49 environmental humidity as the main driving mechanism. A recent work by Ceravolo et al. [22] reported the50 analysis of the environmental effects on the static and dynamic behaviour of the 17th century Sactuary of Vicoforte51 in Italy. Their study covered the analysis of monitoring data from a dense sensor network including wire gauges,52 pressure and load cells, crack meters, temperature sensors, and accelerometers, as well as climatic data from a53 meteorological station close to the monitoring site. The reported results evidenced positive correlations between54 environmental temperature and resonant frequencies, with average annual fluctuations around 5%. Such positive55 correlations are often observed in masonry structures, which is usually ascribed to thermal-induced crack closure56 phenomena (see e.g. [23–27]). Nevertheless, completely different correlations can appear in practice depending57 on the specific material, structural typology and mass distribution, solar radiation, thermal capacitance, etc. A58 noticeable example was provided by Gentile et al. [25] who reported the SHM of the Milan Cathedral in Italy.59 Their results showed negative correlations between resonant frequencies and temperature, which was ascribed to60 the constraints exerted by metallic tie-rods located in the cathedral. These harmless and reversible variations are61 often markedly larger than permanent changes induced by structural defects, resulting in a masking effect in the62 damage identification. To achieve an early-stage damage identification, it is thus indispensable to identify the63 main driving EOC and to remove their influence through proper statistical models.64 Statistical models for pattern recognition in SHM can be generally classified as output-only or input-output65 models. Output-only models directly operate on the selected features to be normalised, without requiring moni-66 toring data from EOC. Common approaches are Principal Component Analysis (PCA) [28], Factor Analysis [29],67 Autoassociative Neural Networks [30], time-series models [31] or Cointegration [32], to mention a few. These68 models exploit correlations between the selected features, in such a way that structural defects affecting such cor-69 relations will rise an anomaly. Nevertheless, since these models do not rely on predictor variables independent70 from structural damage, the physical interpretation of anomalies may be cumbersome and some structural defects71 may go unnoticed. Input-output models instead exploit correlations between damage-sensitive features and EOC.72 Examples of this approach are multiple linear regression (MLR) models [23], AutoRegressive with eXogeneous73 input models (ARX) [33], artificial neural networks [34], or support vector regression [35]. Although this ap-74 proach requires monitoring data from EOC with the subsequent larger archive storage, the physical interpretation75 of anomalies is straightforward since model predictions are built on variables that are intrinsically independent76 3 from any structural damage. Nonetheless, a major difficulty in the definition of these models regards the selection77 of suitable sets of predictors which, again, is eminently case dependent and usually requires the intervention of78 expert judgement.79 Alongside the multiple challenges reviewed above, one of the major obstacles for the extensive implementation80 of long-term SHM is the scarce number of research works in the literature reporting the successful damage iden-81 tification of in-service full-scale structures. The Z24-Bridge in Switzerland firstly studied in 2001 by Maeck and82 co-authors [36] represents the most iconic case study in the field. Before its demolition in 1998, this bridge was83 instrumented with a dynamic SHM system, and subjected to a series of controlled damage scenarios for research84 purposes. Peeters and De Roeck [37] reported the identification of the damage scenarios through statistical pattern85 recognition of the time series of the bridge’s resonant frequencies using ARX. The monitoring records were later86 made available to the scientific community, becoming a benchmark case study to test new damage identification87 techniques (see e.g. [38–40]). In the realm of historic constructions, since it is infeasible to induce controlled88 damage to any structure, most reported case studies in the literature focus on the application of SHM to assess89 and control restoration interventions [41, 42]. In this light, a noteworthy contribution was made by Masciotta et90 al. [43], who implemented a static/dynamic monitoring system to assess the interventions carried out in 2014-201591 to the Saint Torcato church (Portugal) with the aim of correcting structural damage induced by differential soil set-92 tlements. The reported post-rehabilitation results evidenced persistent shifts in the natural frequencies after one of93 the interventions. Mesquita et al. [44] reported the 1-year static/environmental monitoring of the 16th century Foz94 Cˆ oa Church (Portugal), an historical building affected by a series of old crack patterns originated by earthquakes95 occurred in 1755 and 1969. Correlation analyses between static and environmental data allowed to conclude that96 the behaviour of the church was stable and that no interventions were required, the variability in the response97 being only attributable to EOC with no risk to the structural integrity. The number of case studies reporting about98 the damage identification of historic constructions under in-service conditions is considerably lower. Amongst the99 few contributions in the literature, it is worth noting the work by Saisi et al. [45], who reported the damage iden-100 tification of the 13th Century Gabbia Tower in Italy. After removing the environmental effects from the resonant101 frequencies of the tower by MLR, those authors identified permanent frequency decays after a far-field earthquake102 occurred in June 2013. Another noticeable contribution was reported by Ubertini and co-authors [46] on the dam-103 age identification of the San Pietro bell-tower in Perugia (Italy) after the 2016 Central Italy seismic sequence.104 Through a combination of MLR and PCA to filter out environmental effects, their results reported persistent de-105 cays in the resonant frequencies of the tower right after the main shocks of the seismic sequence. Interestingly,106 although the developed damage was not detectable by regular visual inspections, an independent non-linear time-107 history analysis of a numerical model of the tower reported similar frequency decays to the experimental ones108 with damage concentration in the base of the belfry.109 With the aim of addressing the development of unsupervised damage identification of aggregated SHM sys-110 tems with minimal support of expert judgement, this paper presents a novel methodology combining data cleansing111 4 and sparse MLR. The proposed approach comprises a first data cleansing stage using the MCD method to mini-112 mize the prejudicial effects related to the presence of outliers in the training dataset. Subsequently, a SMLR model113 is trained in an unsupervised fashion using the LAR method to eliminate the influence of environmental effects114 upon the dataset of damage-sensitive features. The proposed SMLR model automatically identifies the optimal set115 of EOC predictors, including both static and dynamic (time-delayed) predictors to accommodate environmental116 capacitance effects. The effectiveness of the proposed approach is demonstrated with an application case study of117 a monumental masonry palace, the Consoli Palace in Gubbio (Italy). The Consoli Palace has been instrumented118 since July 14th 2020 with an aggregated static/dynamic/environmental SHM system. A seismic sequence of small119 intensity recently hit the palace between May 15th and May 27th 2021. The sequence included a main earthquake120 of magnitude Mw 4.0 and peak ground acceleration (PGA) of 102.4 cm/s2, followed by five 2.9<Mw<3.6 after-121 shocks in the following days. The most remarkable aspect of this case study regards the extremely closeness of the122 epicenters of the events, only 2-3 km far from the palace, making the investigated case study a unique example of123 a massive masonry building subjected to near-field strong motions. The presented results demonstrate the effec-124 tiveness of the proposed statistical pattern recognition approach to identify the earthquake-induced effects upon125 the resonant frequencies and the amplitudes of two major cracks of the Consoli Palace. Specifically, the conducted126 analyses report decays of up to 2% of the average resonant frequencies of the main bending and torsional modes127 of the palace. Concerning the analysis of the static data, the reported results evidence the appearance of persistent128 earthquake-induced closure of a major crack possibly related to an initial activation of an overturning mechanism129 of one of the fac¸ades of the building. Interestingly, no significant effects are observed upon the time series of the130 mode shapes of the palace nor new structural pathologies are found by preliminary in-situ inspections, indicating131 that the developed damaged condition remains at an early state level not observable by visual inspections. Given132 the singularity of the case study and the gap observed in the literature on the availability of field SHM data of her-133 itage structures for damage identification, the time series of modal signatures, static and environmental monitoring134 data are made available for free use of the scientific community as part of the supplementary material.135 The remainder of the paper is organized as follows. Section 2 introduces the proposed damage identification136 approach. Within this section, Subsection 2.1 overviews the general framework of anomaly detection through137 statistical pattern recognition, and Subsections 2.2 and 2.3 present the proposed data cleansing and data normal-138 isation approaches, respectively. Section 3 presents the numerical results and discussion of the case study and,139 finally, Section 4 concludes the paper.140 2. Removal of Environmental effects using LAR141 2.1. Anomaly detection through statistical pattern recognition142 Let us consider a SHM system tracking ndifferent DSFs collected in an observation matrix Y=y1,...,yn∈143 RN×ncontaining Nobservations. As anticipated above, data normalization constitutes the process of subtracting144 the reversible variability in the selected features in Yinduced by variations in EOC. This is typically achieved145 5 by training a certain statistical model using a set of tpfeature samples from Ydefining a baseline in-control146 population, Ytp ∈Rtp×n, often referred to as the training period (see Fig. 1 (a)). This baseline dataset must147 statistically represent the healthy state of the structure under all possible EOC, being a one-year period often148 adopted. Once trained, the predictions of the model ˆ Ycan be used to phase out the variance due to EOC from Y149 forming the so-called residual error matrix E∈RN×n, that is:150 E=Y−ˆ Y.(1) When the system remains healthy, matrix ˆ Yreproduces the part of the variance of the features driven by151 EOC, while Eonly contains the residual variance stemming from modelling errors. Conversely, if a certain152 damage develops, this only affects the data contained in Ywhile matrix ˆ Yremains unaltered. Therefore, matrix E153 concentrates the damage-induced variance and is apt for being used for damage identification.154 Features Y Features Y;Y Time Time Training period Predictors X LAR Y Y Data cleansing MCD Damage assessment period Time UCL Control chart E Damage (a) (b) (c) (d) (e) Outlier Figure 1: Flowchart of the proposed LAR-based data normalization approach for damage identification. Damage classification can be performed by analysing the residuals in Ethrough three different approaches:155 unsupervised learning, supervised learning, and semi-supervised learning as an intermediate solution. Supervised156 learning is often impractical in the context of historic constructions due to the serious difficulties to generate157 tagged damage data. Unsupervised learning instead simplifies the classification by tagging newly acquired data158 as damaged or non-damaged by analysing their discrepancies with respect to training population dataset (tagged159 as non-damaged or healthy). Unsupervised classification thus limits to damage detection or level 1 diagnostic160 (i.e. verify whether certain damage developed) and, to some qualitative extent, to damage quantification or level161 2 diagnostic (i.e. a measure of the damage extension). This framework is unable to perform prognosis of the162 damage and to offer an estimate of the remaining life of the structure (level 3 diagnostic), being imperative to163 develop numerical models to such purposes. Nevertheless, level 1 diagnostic often suffices for the maintenance of164 heritage assets, whose criticality justifies the execution of in-situ inspections every time any fault is detected.165 Novelty analysis and statistical process control charts are common tools to identify the presence of damage-166 induced anomalies in the time series of residuals in Ein an unsupervised fashion. As sketched in Fig. 1 (e),167 control charts furnish in time a certain statistical distance accounting for nonconformities in the distribution of168 6 the residuals with respect to the training period. This allows to identify out-of-control processes as data points169 violating certain thresholds or in-control regions. A wide variety of control charts are available in the literature,170 although the The Hotelling’s T2control chart [47] is possibly the most commonly used one in the realm of SHM.171 The plotted statistic T2(squared Mahalanobis distance) is defined as:172 T2 i=rE−ET Σ−1 0E−E,i=1,2,...,N/r,(2) and the upper control limit (UCL) related to a 1−αconfidence level when residuals are ideally normally distributed173 reads:174 UCL =krn −kr −rn +n kr −k−n+1Fα;n,kr−k−n+1,(3) with parameter rin Eqs. (2) and (3) being an integer referred to as subgroup size, Ethe mean of the residuals in175 the subgroup of the last robservations, and Eand Σ0the mean values and the covariance matrix of the residuals176 empirically estimated in the training period. Term Fα;n,kr−k−n+1denotes value of the cumulative Fdistribution with177 nand kr −k−n+1 degrees of freedom for a 1 −αconfidence level.178 The sensitivity of the control chart to detect small damage is highly influenced by the quality of the data nor-179 malization model. As previously discussed, the use of input-output statistical models facilitates the interpretation180 of nonconformities, although these models heavily rely on the suitable selection of the predictors set. To optimize181 this process and minimize the need for expert judgement, an automated procedure based on the LAR method is182 implemented in this work. Furthermore, the quality of classification may be also considerably affected by the183 presence of outliers in the monitoring data. Outliers are always present to a certain degree in every feature set in184 SHM, stemming from manifold sources like noise, identification errors, faulty sensors, imperfect mounting, etc.185 Their presence in the training period has a twofold effect: (i) outliers bias the computation of the parameters of the186 data normalization model; and (ii) hinder the proper definition of the UCL. Note in Eq. (3) that the definition of187 UCL depends upon the statistical moments of the residuals in the training population. Therefore, the presence of188 outliers will bias such moments, reducing the damage sensitivity of the classification. To minimize such effects,189 an outlier elimination approach based on the MCD method is proposed in this work. These procedures are assem-190 bled in a new methodology for aggregated long-term SHM sketched in Fig. 1, which comprises the following five191 sequential steps:192 (a) Definition of the baseline population (training period) of damage-sensitive features and potential predictors193 describing the EOC variability.194 (b) Data cleansing using MCD.195 (c) Construction of the statistical model for data normalization using MLR and LAR (SMLR).196 7 (d) Computation of the residual matrix Eby subtracting the predictions by the statistical model ˆ Yfrom the197 observation matrix Y.198 (e) Damage detection through novelty analysis of the Hotelling’s control chart.199 In the remainder of this section, the theoretical fundamentals of MCD and SMLR using LAR are presented in200 Sections 2.2 and 2.3, respectively.201 2.2. Data cleansing using MCD202 The MCD method introduced by Rousseau [48] is a robust estimator of multivariate location and scatter com-203 monly used for outlier detection. Assuming Gaussian-distributed data, the MCD method seeks a subset of given204 size with lowest sample covariance. In the context of this work, the presence of outliers ought to be minimized205 in the training population Ytp. Let H1⊂n1,...,tpobe an h-subset with |H1|=h, and µ1=(1/h)Pi∈H1yiand206 Σ1=[1/(h−1)]Pi∈H1yi−µ1yi−µ1Tbeing the empirical mean and covariance matrix of the data in H1,207 respectively. The Mahalanobis distances of all the data samples in the training population read:208 d1yi=qyi−µ1TΣ−1 1yi−µ1for i=1,...,tp.(4) Now take H2another h-subset such that {d1(i);i∈H2}:=n(d1)1:tp,...,(d1)h:tpowhere (d1)1:tp≤(d1)2:tp≤209 . . . ≤(d1)tp:tpare the ordered distances, and compute µ2and Σ2based on H2. Then det (Σ2)≤det (Σ1)holds with210 equality if and only if µ2=µ1and Σ2=Σ1. This process, also known as the concentration step (C-step), can be211 iteratively repeated as follows:212 1. Select hobservations from the training dataset Ytp conforming Hs.213 2. Compute the empirical covariance µsand Σs.214 3. Compute the Mahalanobis distances dsyi,i=1,...,tp.215 4. Sort the Mahalanobis distances, and select the hobservations having the smallest distances to form Hs+1.216 5. Stop if det (Σs+1)=0 or det (Σs+1)=det (Σs), otherwise go to step 2.217 The sequence det (Σ1)≥det (Σ2)≥det (Σ3)≥det (Σ4)≥. . . is non-negative, so the algorithm always218 converges in finite steps as there is a finite number of h-subsets [49]. Nevertheless, the final calculation of the219 covariance matrix may not converge to the global minimum since it highly depends upon the definition of the220 initial subset H1. The evaluation of all tp hsubsets of size hmay lead to prohibitive computational costs as221 the number of data samples in the training period is usually large. As an alternative solution, Rousseau and222 Driessen [50] proposed a Fast-MCD algorithm based upon the application of the raw MCD to a large number of223 initial candidates for H1. Specifically, the algorithm comprises three sequential stages when the number of samples224 is considerably large (tp>600 [50]): Firstly, several disjoint subsets are drawn from the dataset (a recommended225 8 number of n+1 subsets [49]) and several C-steps are applied to each subset keeping the solutions with lowest226 determinants. Secondly, the subsets are pooled together forming a merged set, and the previously obtained best h-227 subsets are used as the initial subset H1. For every initial subset, several C-steps are applied and the solutions with228 lowest determinants are kept. Finally, the raw MCD method is applied to the full dataset keeping the solution with229 lowest determinant obtained by considering the previously obtained solutions as initial subsets H1. The algorithm230 is given in detail in references [49–52].231 For illustration purposes, Fig. 2 shows a toy example of outlier detection using the MCD method. The Fast-232 MCD algorithm is applied to a dataset of tp=1250 observations and n=2 variables, in which 1000 and 250233 (outliers) observations were drawn from two bivariate normal distributions N1and N2:234 N1            0 0  , 1 1.5 1.5 3             ,N2            2 −2  , 1−0.5 −0.5 1             .(5) The dimension hof the subsets has been selected according to the recommendation by Rousseau and Driessen [50]235 as h≈(n+p+1)/2=626. The Fast-MCD algorithm has been applied to the synthetic dataset starting from five236 subsets with 300 samples, and the obtained analysis results are shown in Fig. 2. The scatter plot in Fig. 2 (a) shows237 the optimal h-set and the remaining tp−hsamples with blue and red solid points, respectively. In this figure, the238 99% tolerance ellipses are also shown. Figure 2 (b) depicts the distance-distance plot, which represents the robust239 Mahalanobis distances (based upon the mean and covariance estimates after applying the MCD method) versus the240 distances computed from the complete dataset. On both axes, threshold limits corresponding to a 99% confidence241 level and defined as qχ2 2,0.99 =3.0349 are also indicated. It is clear in this figure that the MCD concentrates the242 data samples drawn from N1in the h-subset, while isolating most of the samples from N2as outliers. From the243 analysis of Fig. 2 (b), it is found that the classification using the MCD method identifies 231 outliers, while the244 direct analysis of the dataset only leads to 26 outliers.245 −4−2 0 2 4 −6 −4 −2 0 2 4 6 x1 x 2 (a) 02468 10 0 1 2 3 4 Robust Mahalanobis Distance Mahalanobis Distance (b) MCD χ2,0.99 χ2,0.99 Figure 2: Toy example of two overlapping bivariate Gaussian distributions: scatter plot with 99% tolerance ellipses before and after the application of the MCD method (a), and distance-distance plot (b). 9 Nobili Hall x y Roof level1st level 2nd level A8 A9 A7 A5 A3 A10 A11 A12 A2 A1 A4 A6 3rd level D2/T2 DAQ T6 D1/T1 D3/T3 D4/T4 (a) (b) (a.1) (a.2) (a.3) (a.4) T5 Arengo Hall Figure 5: Views of the monitoring and acquisition equipment (a; a.1 - LVDT, a.2 - Accelerometer, a.3 - wireless data transmission, a.4 - DAQ), and layout of the continuous monitoring system (b). Ambient vibrations are sampled at 40 Hz, and crack amplitudes and temperatures from channels D1-D2 and388 T1-T2 are sampled at 0.1 Hz. The monitoring records are stored in separate binary data files containing 30-min-389 long recordings. A Labview script is implemented and used for data acquisition and quality control from remote,390 including amplitude and spectral plots. Single acquisitions from sensors D3-D4 and T3-T6 are taken every 30391 minutes and collected in common text files on a daily basis. The recorded data are sent through the internet to392 a cloud archive, where they are accessed by a remote server computer in the Laboratory of Structural Dynamics393 of the University of Perugia. The monitoring data are collected and processed in an in-house software code394 named MOSS, the Italian acronym of SHM. The software code, whose first release was reported in reference [60],395 implements all the steps involved in SHM as a statistical pattern recognition, including signal pre-processing,396 automated dynamic identification, feature extraction, data cleansing, normalisation, and novelty analysis.397 3.2. Dynamic Identification and continuous monitoring398 A dense ambient vibration test (AVT) was conducted at 13:00 pm CEST on May 7th 2021 in order to charac-399 terize the modal signatures of the Consoli Palace. The test comprised 19 uni-axial piezoelectric accelerometers400 (same technical specifications as those used for the continuous monitoring) with positions sketched in Fig. 6.401 Specifically, the accelerometers layout used in the continuous monitoring system (Fig. 6 (a)) was complemented402 with nine accelerometers covering the two orthogonal directions of the palace at the roof level, and three stations403 at the top level of the bell-tower to monitor rigid-diaphragm motions. Such a configuration was designed with a404 twofold purpose: firstly to identify the interaction of the bell-tower with the main body of the palace and so to405 distinguish between local, global and mixed modes; secondly, to assess the degree of rigidity of the roof level of406 the palace and the possible appearance of out-of-plane bending modes in the main fac¸ades of the palace. Record-407 16 ings from channels A7, A8 and A9 are omitted in the dynamic identification, both in the AVT and the continuous408 monitoring, and reserved for monitoring ground motions. The reason is that the excitation level in the first floor of409 the palace under normal conditions is extremely low, so these accelerometers simply record noise when no seismic410 actions are present. Two asynchronous 30 minutes long acquisitions were carried out and ambient vibrations were411 recorded at a sampling rate of 10652.89 Hz (the maximum rate allowed by the DAQ). The test was conducted412 under normal operating conditions, with micro-tremors induced by traffic in the neighbouring roads and wind413 forces as the main sources of excitation. The mean environmental temperature during the test was 17.2◦and the414 average wind speed was equal to 6.4 km/h as measured from the meteorological observatory of Gubbio centre,415 only 500 m from the palace. Such moderately strong wind speeds favoured the dynamic identification of the416 palace, reaching maximum accelerations of about 0.8 cm/s2, while average ambient vibrations during the contin-417 uous monitoring are typically around 0.2 cm/s2. The ambient vibration recordings were processed in the in-house418 software code MOVA [60], a companion software of MOSS dedicated to AVT. The acceleration time series were419 pre-processed including: (i) removal of non-stationary excitations produced by swinging bells (with a frequency420 of 15-minutes all day and night long) and anomalous spikes through Hanning window filtering, (ii) elimination421 of spurious trends through moving average baseline correction; (iii) fourth order band-pass Butterworth filtering422 with cut-offfrequencies of 0.5 Hz and 100 Hz; and (iv) decimation of the data to 200 Hz.423 A7 A8 A4 A1 A15 A16 A18 A19 A17 A12 A11 A2 A5 A9 A6 A10 A3 A13 A14 A7 A6 A3 A10 A9 A8 A4 A5 A1 A11 A12 A2 (a) Continuous monitoring (b) 7th May 2021 AVT 2nd level z=+18.88 m 1st level z=+6.64 m Roof level z=+29.98 m Figure 6: Comparison of the accelerometers layout during the continuous monitoring of the Consoli Palace (a) and the dense AVT performed on May 7th 2021 (b). Figure 7 (a) furnishes one of the stabilization diagrams obtained using Covariance-based Stochastic Subspace424 Identification (COV-SSI) of the ambient accelerations recorded during the AVT considering a time lag of 6 s.425 The modal identification was performed using the automated procedure proposed in reference [64] for Data-based426 SSI and extended for COV-SSI in reference [60]. In general terms, the procedure started by defining a set of427 increasing time lags tlag, or alternatively the number of block rows/columns jbin the Toeplitz matrix of the output428 correlation matrix (i.e. tlag =(2jb−1)∆twith ∆tbeing the time step of the acceleration series). In particular,429 we defined block rows/columns numbers jbranging from 301 (tlag =6s) to 401 (tlag =8s) with steps ∆jb=5.430 17 Then, for every value of jb, the modal identification was performed considering model orders ranging from 40 to431 80 with steps of 2. Afterwards, all the poles were collected and a first cleansing procedure is applied consisting432 of eliminating complex conjugate poles and poles with damping ratios above 10%. Finally, structural poles were433 distinguished from spurious ones by applying the hierarchical clustering approach reported in [64]. Threshold434 parameters to identify clusters of poles included relative variations of resonant frequencies ∆f<1%, damping435 ratios ∆ζ < 3%, and Modal Assurance Criterion (MAC) values MAC >0.99. This approach allows the automated436 interpretation of the stabilization diagrams in the subsequent continuous OMA. Specifically, nine modes have437 been identified in the frequency range up to 10 Hz and highlighted with thick dashed lines in Fig. 7 (a), and the438 corresponding MAC matrix plot is furnished in Fig. 7 (b). The identified modal signatures (resonant frequencies,439 damping ratios, and Mode Phase Collinearities (MPC)) are collected in Table 1 and the first seven mode shapes440 are shown in Fig. 8. The modes have been classified as global (G), local (L), or high order models (HO) according441 to the interpretation of the mode shapes shown in Fig. 8. Specifically, four global modes have been identified and442 labelled with G-By1, G-T1, G-Bx1, and G-By2 in Fig. 8 and Table 1. Modes G-By1 and G-Bx1 correspond to443 first order bending modes along the y- and the x-directions of the building (refer to Fig. 5 (b)), respectively, mode444 G-By2 refers to a second-order bending mode along the y-direction, and mode G-T1 corresponds to the global445 torsional mode of the palace. Modes L-Bx1 and L-By1 refer to the first order bending modes of the bell-tower446 along the x- and the ydirections, while mode L-T1 corresponds to the first torsional mode of the bell-tower. Note447 that mode L-By1 involves certain torsion in the main body of the palace (see Fig. 8). Finally, modes HO1 and HO2448 show complex interactions between the main body of the palace, including some out-of-plane deformation of the449 roof level. Specifically, modes HO1 and HO2 respectively show symmetric and anti-symmetric movements of the450 point locations of channels A11 and A12. Further analyses to correctly interpret these modes are left for future451 work, possibly with the aid of a numerical model, and, therefore, they have been omitted in Fig. 8. Nevertheless,452 for completeness, the mode shapes of these modes have been included as inserts in Fig. 9 reporting the results of453 the tracking of the resonant frequencies of the Palace through continuous monitoring. These modes identified by454 the automated OMA procedure clearly correspond to columns of stable poles in the stabilization diagram in Fig. 7455 (a) as well as the peaks of the singular values of the spectral matrix, except for the column of poles at about 3.26456 Hz. This mode has been omitted from the identification because its mode shape is almost identical to that of the457 mode at 3.54 Hz with a MAC value of 0.96. Therefore, we decided to omit this mode because of its slightly larger458 complexity and its poorer correlation with the identified poles during the continuous monitoring. As previously459 observed in the work by Kita et al. [59], this column of stable poles may indicate a possible splitting of mode460 L-T1, although more specific analyses should be addressed in this regard to confirm it. The MAC matrix plot in461 Fig. 7 (b) shows that most of the identified modes are highly independent, with MAC values close to zero in most462 of the off-diagonal terms. Only some correlation is observed between modes L-T1 and G-T1 with a MAC value463 of 0.78 but attributable to the common torsion of the main body of the palace, and modes G-By2 and HO2 with464 a MAC value of 0.62 also due to the common bending motion of the palace. Finally, let us remark that all the465 18 identified modes during the AVT are eminently real, with MPC values above 96%.466 Model order Singular Values [dB] Frequency [Hz] (a) (b) New Pole Stable Pole Stable Freq. & MAC Stable Freq. 2.2 -90 -85 -80 -75 -70 -65 -60 2.7 3.3 3.9 4.5 5.1 5.6 6.2 6.8 7.4 7.9 8.5 9.1 9.7 40 45 50 55 60 65 70 75 80 0 1 2 0.5 3 4 5 6 1 71 2 3 84 5 6 97 8 9 0 0.2 0.4 0.6 0.8 1 MAC Figure 7: Stabilization diagram obtained using COV-SSI of the Consoli Palace during the AVT conducted on May 7th 2021 (j=1200, tlag =6 s) (a), and MAC matrix plot (b). Mode 1 - G-By1 Mode 2 - L-Bx1 Mode 3 - L-By1 Mode 4 - G-Bx1 Mode 5 - G-T1 Mode 6 - G-By2 Mode 7 - L-T1 AVT (16 channels)SHM (9 channels) MAC = 0.99 MAC = 0.99 MAC = 0.98 MAC = 0.90 MAC = 0.98 MAC = 0.95 MAC = 0.90 1 2 3 4 5 6 7 1 0.8 0.6 0.4 0.2 0 1 2 3 4 5 6 7 MAC matrix 1 2 3 4 5 6 7 1 2 3 4 5 6 7 * Figure 8: First seven mode shapes identified in the dense AVT and consistently tracked in the continuous monitoring of the Consoli Palace. The mode shapes representative of the continuous monitoring were extracted from the identification of the accelerations recorded on July 17th 2020 12:30 pm CEST. ∗In the comparison of Mode L-T1 between the AVT and the SHM campaign, only the modal displacements at the roof level were considered in the computation of the MAC value since, given the local nature of this mode, only marginal values were obtained at the first and second floors in the AVT. 19 Table 1: Comparison of the experimentally identified modal signatures of the Consoli Palace in the dense AVT and continuous monitoring using the COV-SSI method. AVT - 13:00 pm CEST May 7th 2021 Continuous monitoring - July 2020/May 2021 Mode No. Label Frequency [Hz] Damping ratio [%] MPC∗1[%] SR∗2[%] Mean Frequency [Hz] Variation range [Hz] 1 G-By1 2.32 0.98 98.3 85.5 2.32 2.18 (-5.80%) - 2.44 (+5.10%) 2 L-Bx1 2.99 0.92 100.0 36.25 3.02 2.75 (-8.65%) - 3.45 (+14.29%) 3 L-By1 3.54 0.78 99.9 49.57 3.53 3.32 (-8.54%) - 4.02 (+14.10%) 4 G-Bx1 3.75 2.76 99.0 56.08 3.75 3.51 (-6.36 %) - 3.97 (+5.77%) 5 G-T1 4.22 0.95 99.9 70.94 4.2 3.86 (-8.28%) - 4.51 (+7.34 %) 6 G-By2 5.65 0.72 99.8 57.3 5.53 5.10 (-7.78%) - 5.97 (+8.02 %) 7 L-T1 5.91 0.69 99.8 76.2 6.46 5.96 (-7.75 %) - 7.00 (+8.27%) 8 HO1 7.05 1.65 97.2 43.61 7.05 6.77 (-4.07%) - 7.41 (+5.00%) 9 HO2 8.20 1.67 96.3 76.61 7.97 7.23 (-9.29%) - 9.23 (15.89%) ∗1Mode Phase Collinearity ∗2Success ratio in the identification The previous results were used to define the baseline modal features of the palace to be tracked during the467 continuous monitoring. To do so, a standard frequency tracking approach was implemented to trace the time468 series of the modal features of the palace. This approach consists of grouping the modal poles identified during469 the continuous monitoring by exploiting their similarities with the reference baseline features. Specifically, the470 implemented approach is semi-dynamic. This implies that the reference mode shapes (those identified in the AVT)471 are kept constant throughout all the monitoring period, while the reference resonant frequencies and damping472 ratios vary in time. The comparison between poles is performed in terms of relative variations in the resonant473 frequencies ∆fand MAC values. In every step in the tracking procedure, all the poles complying with pre-defined474 thresholds are sorted according to a metric distance involving both ∆fand MAC values MAC as d:475 d=(1−η)∆f+η(1−MAC),(18) with ηbeing a weighing factor between the contributions of ∆fand MAC. Once sorted, the pole with the lowest476 distance dis collected in the corresponding time series of the mode. On this basis, the same nine modes previously477 identified in the AVT have been tracked throughout all the monitoring period as shown in Fig. 9. To do so, the478 thresholds of maximum relative variations in the resonant frequencies have been selected after some manual tuning479 as 8% for modes 1 to 3, 10% for mode 4, 15% for mode 5, and 5% for modes 6 to 9. Minimum MAC values of480 0.75 have been defined for modes 1 and 4, 0.8 for modes 3, 6 and 8, and 0.9 for modes 7 and 9. The weighing481 factor ηhas been selected as 0.5. Additionally, all the poles with MPC values below 80% are disregarded as482 complex or insufficiently excited modes. It is evident in Fig. 9 that all the resonant frequencies exhibit both daily483 and seasonal fluctuations, more exacerbated as the modes have a more local character with higher frequencies.484 The statistical properties of the tracked modes are collected in Table 1. In this table, the success ratios (SR) have485 been also included, that is, the percentage of times the modes have been identified during the monitoring period. In486 general, it is noted that local modes are poorly tracked with SRs of 36.25% and 49.57% for modes L-Bx1 and L-487 T1, respectively, which is expectable because no sensors are located in the bell-tower during the SHM campaign.488 20 Surprisingly, this is not the case of mode L-T1 which is consistently tracked with a SR of 76.2%. Note in Fig. 8489 that this mode combines certain bending movements concentrated at the roof floor of the palace, which explains490 the success in its identification given the considerable concentration of accelerometers in that level. Global modes491 are tracked with SRs between 56 and 85.5%, which agrees with our previous experience of dynamic SHM of stiff492 masonry structures. Interruptions in the frequency tracking intensify during night-time hours, when the palace493 remains closed to the public and the surrounding vehicle traffic reaches minimum levels. It is also noticeable494 in Table 1 the large environmental effects exhibited by most modes, reaching in most of them variations around495 10% their average values. Such strong effects justify the need for implementing an effective statistical pattern496 recognition for performing damage detection. To this aim, the training period has been defined from July 14th 497 2020 until May 3rd 2021 (≈9 months), followed by the damage assessment period until July 12th 2021.498 Mode 1 G-By1 Mode 2 L-Bx1 Mode 3 L-By1 Mode 4 G-Bx1 Mode 5 G-T1 Mode 6 G-By2 Mode 7 L-T1 Mode 8 HO1 Mode 9 HO2 Training period Damage assessment period 8.0 7.5 6/Sep/2020 16/Sep/2020 9 8 7 6 5 4 3 2 28/Jul/20 16/Sep/20 05/Nov/20 25/Dec/20 13/Feb/21 04/Apr/21 24/May/21 Resonant frequencies [Hz] Figure 9: Tracking of the resonant frequencies of the Consoli Palace from July 2020 until July 2021. The time series of the crack displacements recorded by LVDTs D1, D2, and the temperature readings by499 thermo-couples T1, T2, and T3 are shown in Figs. 10 (a) and (b), respectively, and some statistics are presented500 in Table 2. The monitoring data recorded by temperature sensors T4 and T5, and LVDTs D3 and D4 are omit-501 ted in this work due to difficulties in the data transmission, which made impossible to obtain consistent readings502 throughout the monitoring period. The recordings by LVDTs D1 and D2 exhibit similar behaviours, with ampli-503 tudes ranging between a closing of 0.112 mm to an opening of 0.25 mm with respect to the initial state of the504 monitored cracks. The analysis also evidences the strong effect of environmental temperature in Fig. 10 (b) upon505 the crack displacements in Fig. 10 (a), exhibiting both seasonal and daily fluctuations. The monitored cracks tend506 to open during the winter, while closing during the summer. Also the breathing behaviours of the cracks can be ob-507 served in the zoom inserts in Fig. 10 (a), with closing during the day-time and opening during the night-time. The508 21 monitored temperatures range from 0 to 35 ◦C. Note in Table 2 that sensor T3, which is almost located outdoor,509 shows significantly larger daily fluctuations compared to indoor sensors T1 and T2.510 0 0.3 -0.1 0.1 0.4 Crack Displacements [mm] 0 10 20 30 40 Temperature [ºC] (a) (b) 28/Jul/20 16/Sep/20 05/Nov/20 25/Dec/20 13/Feb/21 04/Apr/21 24/May/21 T1 T2 T3 0.2 0.20 0.15 0.10 11/Oct/20 05/Nov/20 12 16 20 11/Oct/20 05/Nov/20 Training period Damage assessment period D1 D2 OpeningClosing Figure 10: Time series of crack amplitudes of channels D1 and D2 (a), and time series of environmental temperatures of channels T1, T2, and T3 (b) from July 2020 to July 2021. Table 2: Statistics of measured crack displacements (D1 and D2) and temperature data (T1, T2 and T3) from July 2020 to July 2021. Var. Mean Val. [mm] Min Val. [mm] Max Val. [mm] σ[mm] D1 1.20E-01 -0.035 0.24 7.53E-02 D2 1.70E-01 -0.112 0.25 7.19E-02 Var. Mean Val. [◦C] Min Val. [◦C] Max Val. [◦C] σ[◦C] T1 17.3 5.78 31.3 7.32 T2 17.4 2.69 35.5 8.07 T3 16 -0.06 34.6 8 3.3. Statistical Pattern Recognition results511 With the aim of addressing the elimination of EOCs from the resonant frequencies and the crack amplitudes,512 some preliminary correlation analyses have been conducted as reported in Figs. 11 and 12. In the subsequent513 results, only the resonant frequencies of modes with SRs above 50% are considered, namely G-By1 (Mode 1), L-514 T1 (Mode 3), G-Bx1 (Mode 5), G-T1 (Mode 5), L-T1 (Mode 7), and HO2 (Mode 9). In addition, because of space515 constraints, only the correlations with the temperature sensors yielding maximum coefficients of determination R2 516 are presented herein.517 Regarding the analysis of the resonant frequencies in Fig. 11, it is observed that negative frequency/temperature518 correlations are found in all the modes. This indicates that the global stiffness of the palace decreases as temper-519 ature rises. As previously discussed in the introduction, such a trend is quite uncommon in masonry structures520 such as slender towers or churches (see e.g. [25–27]). Most authors agree to hypothesize positive correlations521 to be driven by thermal-induced closure of micro-cracks in the mortar joints. In the case of the Consoli Palace,522 negative frequency/temperature correlations were previously found by Kita et al. [59]. Those authors attributed523 this trend to temperature-induced slackening of some metallic tie rods installed in the Arengo hall to restrain the524 22 lateral thrusts exerted by the barrel-vault ceiling, as well as the possible contribution of the existing macro cracks.525 Overall, considerably linear frequency-temperature correlations are observed in the natural frequencies of modes526 3 and 4, whereas noticeably non-linear correlations are identified instead for modes 1, 5, 7 and 9, which may527 be ascribed to the existence of complex temperature-driven mechanisms or a strong dependence on unmonitored528 EOC. The large scatter in the correlation plots of modes G-By1, G-x1, and L-T1 may indicate the presence of529 thermal capacitance effects, that is some delays in heat transfer from the position of the thermocouples through530 the cross-sections of the masonry walls. The most significant correlations with temperature are found for modes531 L-By1 and G-T1 with coefficients of determination R2of 0.85 and 0.72, respectively. This strong correlation for532 global torsional mode G-T1 is expectable since it is dominated by the shear stiffness of the external walls of the533 palace with direct exposure to the outdoor environment. Considering the global bending modes of vibration G-534 By1 and G-Bx1, the higher degree of temperature correlation is observed for mode G-By1. This can be ascribed535 to the large exposed surface of the two longitudinal walls along the north-south fac¸ades of the palace, which con-536 tribute to the largest extent to mode G-By1. Conversely, two out of the four transversal walls along the East-West537 direction of the palace and activated by mode G-Bx1 are located indoor and, thus, are less affected by the external538 environment. Regarding the temperature correlations observed for local modes L-By1 and L-T1, it is noted that539 the local bending mode is highly affected by thermal variations (R2=0.85), while the local torsional mode only540 exhibits a moderate correlation (R2=0.32). The thermal sensitivity of the former is attributable to the circumstance541 that the bell-tower is directly exposed to the outdoor environment. In this case, the flexural restraint imposed by542 the roof floor is expected not to be sensibly affected by the environmental temperature. Conversely, the restraint543 of the roof floor to torsional rotations at the base of the bell-tower might be considerably affected by tower/floor544 differential thermal expansions. Indeed, this may explain the large scatter observed for this mode, which may be545 indicative of important thermal capacitance effects. With regard to the correlations between crack amplitudes D1546 and D2 and temperature data, it is noted in Fig. 12 that crack amplitudes also exhibit negative correlations with547 the environmental temperature. Such a trend indicates that cracks tend close as the environmental temperature548 rises with the subsequent expansion of the masonry volumes, and vice versa. Almost perfect correlation is found549 for LVDT D1 (located in the South fac¸ade of the palace) with a coefficient of determination very close to 1. Con-550 versely, a more complicated correlation is found for LVDT D2 with substantial scatter around the regression lines.551 This fact again evidences the potential existence of thermal capacitance effects.552 23 y=2.35-1.7e-3x MSE=9.92e-5, R2=0.33 y=2.38-5.6e-3x+1.04e-4x2 MSE=1.05e-5, R2=0.37 R2=0.85 R2=0.15 R2=0.72 R2=0.32 R2=0.10 Temperature T2 [ºC]Temperature T1 [ºC] 2.38 2.40 2.36 2.34 2.32 2.30 2.28 2.26 510 15 20 25 30 0 Temperature T2 [ºC] Temperature T1 [ºC] Temperature T1 [ºC] Temperature T2 [ºC] y=3.66-7.6e-3x MSE=5.63e-4, R2=0.85 y=3.64-5.1e-3x-6.51e-5x2 MSE=5.54e-4, R2=0.85 y=3.76-6.54e-4x MSE=2.38e-5, R2=0.15 y=3.77-1.7e-3x+2.69e-5x2 MSE=2.49e-5, R2=0.16 y=4.32-6.3e-3x MSE=7.21e-4, R2=0.72 y=4.36-1.2e-3x+1.53e-4x2 MSE=7.02e-4, R2=0.73 y=6.64-1.1e-2x MSE=4.08e-3, R2=0.32 y=6.82-3.3e-2x+5.89e-4x2 MSE=4.27e-3, R2=0.35 y=8.22-1.5e-2x MSE=1.03e-2, R2=0.10 y=8.93-1.0e-1x+2.4e-3x2 MSE=1.70e-2, R2=0.19 Frequency Mode 1 [Hz] Frequency Mode 3 [Hz] Frequency Mode 5 [Hz] Frequency Mode 7 [Hz] Frequency Mode 9 [Hz] Frequency Mode 4 [Hz] R2=0.33 3.65 3.60 3.55 3.50 3.45 3.40 3.35 50 10 15 20 25 30 3.78 3.80 3.76 3.74 3.72 3.70 50 10 15 20 25 30 35 4.30 4.35 4.25 4.20 4.15 4.10 4.05 50 10 15 20 25 30 35 6.8 6.9 6.7 6.6 6.5 6.4 6.3 6.2 6.1 510 15 20 25 30 9.2 9.4 9.0 8.8 8.6 8.4 8.3 7.8 7.6 7.4 7.2 510 15 20 25 30 L-By1 G-Bx1 G-T1 G-By1 L-T1 HO2 Figure 11: Correlations between the natural frequencies of the Consoli Palace and the environmental temperature in the training period from July 14th 2020 until May 3rd 2021 (12878 data samples). R2=0.97 R2=0.62 Temperature T1 [ºC] Temperature T3 [ºC] Crack displacements D1 [mm] Crack displacements D2 [mm] y=0.29-1.0e-2x MSE=1.55e-4, R2=0.97 y=0.27-7.6e-3x-6.60e-5x2 MSE=1.51e-4, R2=0.97 y=0.23-7.0e-3x MSE=1.22e-3, R2=0.62 y=0.17+1.1e-3x-2.39e-4x2 MSE=1.20e-3, R2=0.66 0.25 0.20 0.15 0.10 0.05 0.00 -0.05 5 10 15 20 25 30 0.25 0.20 0.15 0.10 0.05 0.00 -0.05 -0.10 50 10 15 20 25 30 35 R2=0.66 Figure 12: Correlation between the crack displacements monitored by LVDTs D1 and D2 and the environmental temperature in the training period from July 14th 2020 until May 3rd 2021 (12878 data samples). In the subsequent analyses, an autoregressive (AR) time series model has been implemented to complete the553 time series of resonant frequencies. In general, an AR model conceives an arbitrary observation sequence x[n] at554 instant nas a linear combination of p(model order) past observations:555 x[n]=a0+ p X k=1 akx[n−k]+ε[n],(19) where akare prediction coefficients, a0is a constant value, and ε[n] is a white noise process. The implemented556 algorithm (fillgaps.m Matlab function) determines local forward and reverse AR models using signal segments557 of certain length laround the missing data, and estimates the local prediction coefficients akusing the Burg’s558 method (for further details, readers may refer to reference [65]). To the purpose of this work, segments of 144 data559 points (corresponding to 3 days of monitoring data) and a model’s order of p=3 have been found suitable and560 24 selected henceforth. Based upon the reconstructed time series, the MCD-based outliers detection algorithm previ-561 ously introduced in Section 2.2 has been applied to the time series of resonant frequencies in the training period as562 shown in Fig. 13. In particular, the dimension of the subsets has been selected according to the recommendation563 by Rousseau and Driessen [50] as h=(n+p+1)/2=(12878 +6+1)/2≈6443. Once the optimal h-subset is564 found, all the data samples are sorted according to their Mahalanobis distances from the optimal set. Afterwards,565 20% of the data points with largest distances are considered as outliers and disregarded in the subsequent data566 normalisation. The MCD approach was not applied to the time series of monitoring data from the LVDTs because567 no significant outliers were observed, and only a few abnormal data points were manually eliminated. Note that568 no outliers elimination was conducted beyond the training period leaving the time series intact. This is crucial to569 prevent the erroneous elimination of nonconformities that may stem from any structural pathology.570 F. Mode 5 [Hz] F. Mode 7 [Hz] F. Mode 9 [Hz] F. Mode 9 [Hz] F. Mode 7 [Hz] F. Mode 5 [Hz] F. Mode 5 [Hz] F. Mode 9 [Hz] F. Mode 7 [Hz] F. Mode 7 [Hz] F. Mode 9 [Hz]F. Mode 9 [Hz] F. Mode 5 [Hz] F. Mode 7 [Hz] F. Mode 5 [Hz] -5 2 64-2 F. Mode 1 [Hz] F. Mode 1 [Hz] F. Mode 1 [Hz] F. Mode 1 [Hz] F. Mode 1 [Hz] F. Mode 3 [Hz] F. Mode 3 [Hz] F. Mode 3 [Hz] F. Mode 3 [Hz] F. Mode 3 [Hz] F. Mode 4 [Hz] F. Mode 4 [Hz] F. Mode 4 [Hz] F. Mode 4 [Hz] F. Mode 4 [Hz] F. Mode 9 [Hz] F. Mode 9 [Hz] F. Mode 9 [Hz] F. Mode 9 [Hz] F. Mode 9 [Hz] F. Mode 9 [Hz] F. Mode 7 [Hz] F. Mode 7 [Hz] F. Mode 7 [Hz] F. Mode 7 [Hz] F. Mode 7 [Hz] F. Mode 7 [Hz] F. Mode 5 [Hz] F. Mode 5 [Hz] F. Mode 5 [Hz] F. Mode 5 [Hz] F. Mode 5 [Hz] F. Mode 5 [Hz] F. Mode 4 [Hz] F. Mode 4 [Hz] F. Mode 4 [Hz] F. Mode 4 [Hz] F. Mode 4 [Hz] F. Mode 4 [Hz] F. Mode 3 [Hz] F. Mode 3 [Hz] F. Mode 3 [Hz] F. Mode 3 [Hz] F. Mode 3 [Hz] F. Mode 3 [Hz] F. Mode 1 [Hz] -5 0 500 1000 0 5 F. Mode 1 [Hz] F. Mode 1 [Hz] F. Mode 1 [Hz] F. Mode 1 [Hz] F. Mode 1 [Hz] -5 -5 0 5 0 5 -5 0 5 -5 0 5 -5 0 5 -5 0 5 -5 0 5 -4 0 -5 0 5 -5 0 5 -5 0 5 -5 0 5 -10 -5 50 10 -10 -5 50 10 -10 50 10 -10 -5 50 10 -10 -5 50 10 -10 -5 50 10 -5 0 5 -5 0 5 -5 0 5 -5 0 5 -5 0 5 -5 0 5 -4 -2 20 4 -4 -2 20 4 -4 -2 0 42 -4 -2 20 4 -2 0 2 4 -4 -2 20 4 0 500 1000 1500 0 1000 2000 0 500 1000 0 500 1000 0 500 1000 -2 20 4 -2 20 4 -2 20 4 -2 20 4 -2 20 4 -2 20 4 -10 0 10 -5 0 5 -5 0 5 -2 0 2 4 -10 0 10 -5 0 5 -5 0 5 -2 0 4 2 -5 0 5 -5 0 5 -5 0 5 -5 0 5 -2 0 4 2 -5 0 5 -10 0 10 -5 0 5 -2 0 4 2 -5 0 5 -5 0 5 -2 0 2 4 -5 0 5 -10 0 10 -5 0 5 -5 0 5 -5 0 5 -5 0 5 -10 0 10 -5 0 5 -5 0 5 Outlier No-outlier G-By1 L-By1 G-Bx1 G-T1 L-T1 HO2 Figure 13: Correlation analysis between the resonant frequencies of the Consoli Palace (Modes G-By1/Mode 1, L-T1/Mode 3, G-Bx1/Mode 4, G-T1/Mode 5, L-T1/Mode 7, and HO2/Mode 9) and outliers detection results. Twenty percent of the data points with largest Mahalanobis distances to optimal h-subset selected by MCD are considered as outliers. The intricate correlations between the dynamic/static features and the environmental conditions reported in571 Figs. 11 and 12 justify the implementation of the SMLR model previously presented in Section 2.3. Specifically, a572 total of 48 potential predictors are considered. These comprise linear and quadratic (denoted with the subscript 2)573 versions of the time series of environmental temperatures by thermo-couples T1, T2 and T3. Additionally, with the574 aim of accommodating potential thermal capacitance effects in the palace, time delayed versions of the previous575 time series are also accounted for. These include delays of 30 min (2 samples), 1 hour (4 samples), 2 hours (8576 samples), 5 hours (20 samples), 12 hours (48 samples), 24 hours (96 samples), and 48 hours (192 samples). On577 25 strate the importance of cleansing the training dataset. Finally, with the aim of providing further insight into the676 effectiveness of the classifications, the areas under the ROC (AUC) and Precision-Recall (PAUC) have been also677 computed as comprehensive quality metrics. All things considered, it is evident in Fig. 19 (b) that the pattern678 recognition including data cleansing (denoted with solid lines) proves far better performance using both SMLR679 or PCA. Indeed, the classification conducted without outliers elimination achieves limited areas of AUC=0.8698680 and PAUC=0.5463 in the case of SMLR, and AUC=0.8811 and PAUC=0.5002 in the case of PCA. Instead,681 when the cleansing of the training population is included, the classifications using both SMLR (AUC=0.9749,682 PAUC=0.8766) or PCA (AUC=0.9739, PAUC=0.8834) approach the perfect classifier (AUC=PAUC=1.0). With683 regard to the comparison between SMLR and PCA, very limited differences are found in terms of ROC/PR curves684 when all the selected resonant frequencies are included in the classification. Nevertheless, larger differences arise685 when inspecting the classifications obtained accounting for an increasing number of features as shown in Fig. 20.686 It is noted in Fig. 20 (a) that almost equally effective classifications are obtained using SMLR for every subset687 of features, while the classification using PCA in Fig. 20 (b) cannot achieve a comparable effectiveness until688 including all the modes in the classification. Indeed, a comparable classification is only found when including689 high-order Mode 9 (HO2). This is also confirmed by examining the AUCs of the previous ROC curves in Fig. 20690 (c), which demonstrates that the damage classification using SMLR considerably outperforms the one obtained691 by PCA. Concerning crack amplitudes, almost perfect detection can be observed in Fig. 21. In the control chart692 shown in Fig. 21 (a), the number of outliers considering a 95% UCL increases from 4.99% to 84.79% before and693 after the seismic sequence. Furthermore, the ROC and PR curves reported in Fig. 21 (b) evidence almost perfect694 classification, with global metrics of AUC=0.9943 and PAUC=0.9760.695 0 50 100 150 200 250 300 Hotelling’s T2 28/Jul/20 16/Sep/20 05/Nov/20 25/Dec/20 13/Feb/21 04/Apr/21 24/May/21 13/Jul/21 0 50 100 150 200 Hotelling’s T2 0 0.2 0.4 0.6 0.8 1 0.0 0.2 0.4 0.6 0.8 1.0 False Positive Rate True Positive Rate 0 0.2 0.4 0.6 0.8 1 0.0 0.2 0.4 0.6 0.8 1.0 Recall Precision 95% UCL PCA SMLR (a) 95% UCL Training period 03/05/21 Training period 03/05/21 Seismic sequence 15/05/21 8.55% 7.83% 71.93% 68.4% (b) Random classifier PCA SMLR Without outliers With outliers Figure 19: Hotelling’s T2control charts of the residuals of the resonant frequencies of the Consoli Palace considering SMLR and PCA (3 PCs) (a), and quality assessment in terms of ROC/PR curves (b). 32 0 0.2 0.40.60.8 1 0.0 0.2 0.4 0.6 0.8 1.0 False Positive Rate True Positive Rate (a) 2 Modes 3 Modes 4 Modes 5 Modes 6 Modes 0 0.2 0.40.60.8 1 0.0 0.2 0.4 0.6 0.8 1.0 False Positive Rate True Positive Rate (b) 2 Modes 3 Modes 4 Modes 5 Modes 6 Modes 0.80 0.85 0.90 0.95 1.00 AUC (c) SMLR PCA Figure 20: ROC curves considering an increasing number of resonant frequencies using SMLR (a) and PCA (b) (3 PCs), and comparison in terms of AUCs (c). Modes are included in the classification in increasing order of frequency. 28/Jul/20 16/Sep/20 05/Nov/20 25/Dec/20 13/Feb/21 04/Apr/21 24/May/21 13/Jul/21 0 20 40 60 80 100 120 Hotelling’s T2 0 0.2 0.4 0.6 0.8 1 0.0 0.2 0.4 0.6 0.8 1.0 False Positive Rate/Recall True Positive Rate 0 0.2 0.4 0.6 0.8 1 0.0 0.2 0.4 0.6 0.8 1.0 Precision SMLR 95% UCL Training period 03/05/21 Seismic sequence 15/05/21 4.99% 84.79% ROC curve Precision/Recall curve (a) (b) Figure 21: Hotelling’s T2control charts of the residuals of the crack amplitudes D1 and D2 of the Consoli Palace considering SMLR (a), and quality assessment through a ROC/PR curve (b). The characterization of the earthquake-induced decays in the resonant frequencies of the Consoli Palace is696 reported in Fig. 22. The analysis is performed by the individualized study of the residuals of the resonant fre-697 quencies obtained using both SMLR and PCA and presented in Figs. 22 (a) and (b), respectively. To facilitate698 the identification of shifts and minimize the effects of residual EOC variability, moving averages of order 192 (4699 days) are included with solid black lines. Additionally, the convergence of the average of the residuals before and700 after the seismic sequence of May 15th are also included and denoted with dashed yellow lines. Although it was701 concluded from the previous analysis in Fig. 19 that PCA may show a comparable classification performance to702 SMLR when including all the considered resonant frequencies, it is evident in Fig. 22 (b) that this approach fails to703 provide a clear interpretation of the decays in the resonant frequencies. In fact, only a clear shift starting on May704 15th is noticeable in Mode 4, while just mild deviations are recognized for Modes 1 and 3. Moreover, since PCA705 only exploits correlations between the estimators, the sign of the shifts may be hardly interpreted and/or related706 to physical phenomena. On the contrary, clear decays starting right after the onset of the seismic sequence are707 observable when implementing SMLR in Fig. 19 (a). Note that the signs of the shifts observed in this figure are all708 negative, indicating the appearance of earthquake-induced stiffness losses in the palace. It is important to remark709 that, although the number of data samples in the evaluation period is still limited, the mean convergence curves in710 Fig. 19 (a) suggest certain stabilization which allows to state the appearance of persistent damage in the palace.711 These results are further investigated in Fig. 23 through the analysis of the squared Mahalanobis distances (D2)712 33 of the residuals with respect to the training population. Data samples before and after the seismic sequence are713 denoted in this figure with Regions I and II, respectively. The probability distributions of the distances in Fig. 23714 (a) (plotted in logarithmic scale and normalized to have unit maximum probability) exhibit clear shifts in terms of715 mode and mean values after the seismic sequence, which further supports the claim of the appearance of persistent716 structural damage. The earthquake-induced variations in the correlations between the resonant frequencies and the717 environmental temperature are investigated in Fig. 22 (b). In these analyses, the variation range of environmental718 temperature (channel T1) has been divided into 50 equally spaced disjoint intervals, and the statistical distribution719 of resonant frequencies has been described interval-wise through a frequentistic analysis. In is noted in this figure720 that an almost constant decay is found in Mode 3 throughout all the temperature range. Conversely, decays in721 Modes 1 and 4 concentrate in the temperature range up to 20◦, while almost no variation is observed at higher722 temperatures. Nonetheless, future analyses should appraise a longer damage assessment period to fully character-723 ize the permanent damage-induced variations in the environmental effects, covering the temperature range below724 15◦which remains unexplored in the present work.725 Following a similar approach, Figs. 24 (a) and (b) report the obtained residuals of crack amplitudes D1 and D2726 using SMLR and the analysis of their correlations with the environmental temperature (channel T1), respectively.727 In this case, it may be clearly concluded from Fig. 24 (a) that crack amplitudes D1 (in the south fac¸ade of the728 palace) experienced almost no variation after the seismic sequence, while a steep and stable shift is found in D2729 (in the north fac¸ade of the palace). This fact is also confirmed when analysing the correlations with environmental730 temperature in Fig. 24 (b), where consistent decreases (closing) are found in the whole temperature range.731 34 −0.10 −0.08 −0.06 −0.04 −0.02 0.00 0.02 0.04 0.06 0.08 0.10 Freq. Mode1[Hz] −0.20 −0.15 −0.10 −0.05 0.00 0.05 0.10 0.15 0.20 Freq. Mode3[Hz] 28/Jul/20 16/Sep/20 05/Nov/20 25/Dec/20 13/Feb/21 04/Apr/21 24/May/21 13/Jul/21 −0.15 −0.10 −0.05 0.00 0.05 0.10 0.15 Freq. Mode4[Hz] −0.10 −0.08 −0.06 −0.04 −0.02 0.00 0.02 0.04 0.06 0.08 0.10 Freq. Mode 1 [Hz] −0.20 −0.15 −0.10 −0.05 0.00 0.05 0.10 0.15 0.20 Freq. Mode 3 [Hz] 28/Jul/20 16/Sep/20 05/Nov/20 25/Dec/20 13/Feb/21 04/Apr/21 24/May/21 13/Jul/21 −0.15 −0.10 −0.05 0.00 0.05 0.10 0.15 Freq. Mode 4 [Hz] Training period 03/05/21 Seismic sequence 15/05/21 +3σ +3σ (a) SMLR (b) PCA Figure 22: Residuals of the first three considered resonant frequencies of the Consoli Palace using SMLR (a) and PCA (b). Black solid lines represent the moving averages of order 192 (4 days) of the residuals, while yellow dashed lines represent the convergence of the mean values of the residuals before and after the seismic sequence occurred on May 15th 2021. 35 1 2 3 4 D2Freq. Mode1[Hz2] 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 D2Freq. Mode3[Hz2] 28/Jul/20 16/Sep/20 05/Nov/20 25/Dec/20 13/Feb/21 04/Apr/21 24/May/21 13/Jul/21 0 1 2 3 4 5 6 D2Freq. Mode4[Hz2] −8 −6 −4 −2 0 2 −8 −6 −4 −2 0 2 0 0.2 0.4 0.6 0.8 1 −8 −6 −4 −2 0 2 Seismic sequence 15/05/21 Temperature T1 [ºC]Temperature T1 [ºC] Freq. Mode1[Hz]Freq. Mode3[Hz]Freq. Mode4[Hz] Region I Region II 0 x102 x103 x103 Training period 03/05/21 Region I Region II log(D2 Freq. Mode1)log(D2 Freq. Mode3)log(D2 Freq. Mode4) 2.22 2.24 2.26 2.28 2.30 2.32 2.34 2.36 2.38 2.40 3.20 3.30 3.40 3.50 3.60 3.70 510 15 20 25 30 3.50 3.60 3.70 3.80 3.90 4.00 510 15 20 25 30 (a) (b) Figure 23: Identification of earthquake-induced decays in the resonant frequencies of Modes 1, 3 and 4 of the Consoli Palace. Statistical analysis of the distribution of Mahalanobis distances of the residuals against the training population (a), and characterization of the earthquake-induced damage in the frequency/temperature correlations (b). Error bars in (b) indicate the standard deviation. −0.04 −0.02 0.00 0.02 0.04 LVDT D1 [mm] 28/Jul/20 16/Sep/20 05/Nov/20 25/Dec/20 13/Feb/21 04/Apr/21 24/May/21 13/Jul/21 −0.20 −0.15 −0.10 −0.05 0.00 0.05 0.10 LVDT D2 [mm] −0.10 −0.05 0.00 0.05 0.10 0.15 0.20 0.25 LVDT D1 [mm] −0.20 −0.10 0.00 0.10 0.20 0.30 LVDT D2 [mm] Training period 03/05/21 Seismic sequence 15/05/21 +3σ +3σ (a) 510 15 20 25 30 Temperature T1 [ºC] Region I Region II Region I Region II (b) sD1 sD2 Figure 24: Residuals of crack amplitudes D1 and D2 of the Consoli Palace using SMLR (a), and identification of earthquakeinduced variations in the crack/temperature correlations (b). Black solid lines in (a) represent the moving averages of order 192 (4 days) of the residuals, while yellow dashed lines represent the convergence of the mean values of the residuals before and after the seismic sequence occurred on May 15th 2021. Error bars in (b) indicate the standard deviation. 36 To conclude the previous analysis, Table 5 summarizes the identified earthquake-induced damage in the Con-732 soli Palace. To compute the earthquake-induced shifts in the considered estimators, the statistical moments of733 the residuals presented in Figs. 22 and 24 are estimated by non-parametric bootstrap with 800 repetitions. As734 a measure of the uncertainty in the identification, the quantities in parentheses in Table 5 indicate the standard735 deviations of the empirical mean values computed in the bootstrap repetitions. In terms of resonant frequencies,736 decays concentrate in Modes 3 (L-T1), 5 (G-T1), 1 (G-By1) and 4 (G-Bx1) in decreasing order. Note that, given737 the relative orientation of the palace with respect to the epicenter of the main shock (see Fig. 17 (a)), damage is738 expected to concentrate along the y-direction of the building, primarily affecting the first bending mode along that739 direction (G-By1) as well as the torsional modes (L-T1 and G-T1). This claim is supported by the results reported740 in Table 5, where the decays in the first order bending modes along the y- and x-directions amount to 0.62 and741 0.54%, respectively. Besides, the largest decays are found for torsional Modes 3 (local) and 5 (global) with val-742 ues of 2.04 and 0.93%, respectively, indicating that the seismic events had largest influence upon the torsional743 stiffness of the palace. Interestingly, an increase of 0.62% is found for local Mode 9, which may indicate some744 earthquake-induced rearrangement of the tower/building interaction. However, given the limited performance of745 the data normalization of this mode shown in Fig. 16, as well as the largest uncertainty found in its estimation746 as reported in Table 5, the analysis of a longer monitoring period would be required to confirm whether this is a747 persistent variation or not. It is important to remark that no significant variations are found in the MAC values748 between the mode shapes after and before the seismic sequence, with values very close to 1 as reported in Table 5.749 No clear persistent variations were observed either in the time series of MAC values all throughout the monitoring750 period, thereby their analysis has been omitted herein. This circumstance may indicate the registered damage is751 very moderate and sustains no severe structural risk to the palace. In fact, preliminary in-situ inspections have752 not revealed any new pathology in the palace, which suggests that the developed damage remains at a degree not753 observable by visual examinations. With regard to the crack amplitudes, the results in Table 5 confirm that crack754 D1 was not affected by the seismic sequence, while a clear closure of crack D2 of about 8.9E-2 mm is found. Note755 that LVDT D2 is located bridging a major crack located in the north fac¸ade of the building, which was presumably756 originated as a result of an incipient overturning failure mechanism of the western fac¸ade. Instead, LVDT D1 is757 monitoring a crack relating the local overturning of the loggia in the south fac¸ade. Following the previous discus-758 sion on the incidence direction of the seismic shocks, it is reasonable to state that these will mainly affect the north759 fac¸ade of the palace. Finally, it is important to emphasize that, whilst the detected anomaly in D2 is significant in760 relatively terms, the closure of crack D2 is very limited and supports the previous statement on the mild severity761 of the earthquake-induced damage.762 37 Table 5: Characterization of the shifts in the resonant frequencies and crack amplitudes of the Consoli Palace after the May 15th 2021 seismic sequence. Subscripts I and II relate the statistical moments calculated before and after the seismic sequence, respectively. July 17th 2020 to May 15th 2021 May 15th 2021 to July 18th 2021 Comparison Estimator yMean ¯ yIStd. dev. σy,IMean ¯ yII Std. dev. σy,II 100 ·(¯ yII −¯ yI)/¯ yIMAC Mode 1 (G-By1) [Hz] 2.319 (±1.33E-04) 0.020 2.304 (±3.37E-04) 0.016 -0.62 0.977 Mode 3 (L-By1) [Hz] 3.514 (±1.99E-04) 0.068 3.442 (±4.26E-04) 0.041 -2.04 0.943 Mode 4 (G-Bx1) [Hz] 3.750 (±1.20E-04) 0.014 3.730 (±4.69E-04) 0.027 -0.54 0.903 Mode 5 (G-T1) [Hz] 4.186 (±2.38E-04) 0.057 4.147 (±6.39E-04) 0.031 -0.93 0.974 Mode 7 (L-T1) [Hz] 6.477 (±8.03E-04) 0.136 6.479 (±1.79E-03) 0.110 0.04 0.962 Mode 9 (HO2) [Hz] 7.971 (±1.61E-03) 0.292 8.020 (±3.57E-03) 0.248 0.62 0.977 Crack D1 [mm] 0.115 (±7.20E-05) 0.074 0.122 (±1.93E-04) 0.037 - - Crack D2 [mm] 0.120 (±2.21E-04) 0.072 0.031 (±4.26E-04) 0.036 - - 4. Conclusions763 This paper has presented the development of a novel methodology for statistical pattern recognition and iden-764 tification of earthquake-induced structural damage. The proposed methodology comprises a first data cleansing765 stage using the MCD method to mitigate the adverse effects related to the existence of outliers in the training popu-766 lation. Afterwards, a sparse multivariate linear regression model is trained using LAR to eliminate the influence of767 EOC upon the dataset of damage-sensitive features. The proposed SMLR model allows to automatically identify768 the optimal set of EOC predictors (both static and dynamic), with the subsequent enhancement in the data normal-769 ization and minimal need for expert judgement. The effectiveness of the proposed approach is demonstrated with770 an application case study of a monumental masonry palace, the Consoli Palace in Gubbio. The Consoli Palace771 has been instrumented since July 14th 2020 with an aggregated static/dynamic/environmental SHM system. A772 seismic sequence of moderate intensity hit the palace on May 15th to May 27th 2021, including a main earthquake773 of magnitude Mw 4.0 followed by five 2.9<Mw<3.6 aftershocks with epicenters located only 2-3 km far from774 the palace. The reported results have demonstrated the effectiveness of the proposed approach to detect and quan-775 tify the earthquake-induced effects upon the resonant frequencies and the amplitudes of two major cracks of the776 Consoli Palace. The key findings and contributions of this work can be summarized as follows:777 •A new damage identification methodology is proposed combining data cleansing and sparse multivariate778 regression. The reported results have demonstrated that the proposed approach can handle large sets of779 potential predictors in a fully automated way, including both static and dynamic (i.e. time delayed) EOC780 time series with minimal assistance by expert judgement.781 •The reported results have highlighted the critical influence of data normalisation for achieving effective782 damage identification. Additionally, it has been evidenced that output-only data normalisation models such783 as PCA may fail at quantifying structural damage, providing anomalies in the residuals hardly attributable784 to physical phenomena.785 •Maximum earthquake-induced decays of 2% are found for the fundamental bending and torsional modes of786 the Consoli Palace. Slightly stronger effects are found in the bending mode along the east-west direction787 38 of the palace, which is conceivably explained by the relative orientation of the palace with respect to the788 incidence direction of the seismic shock. This observation is also justified by the analysis of the static data,789 where a persistent crack closure in the north fac¸ade of the palace has been clearly identified.790 •No significant earthquake-induced effects are observed upon the time series of mode shapes of the palace.791 This circumstance, along with the impossibility to find new damage patterns in the palace by preliminary792 in-situ inspections, may indicate that the newly acquired damage condition remains at an early stage of793 development not visually observable and with no critical risk to the structural integrity of the building.794 Acknowledgements795 This work was supported by the Italian Ministry of Education, University and Research (MIUR) through796 the funded project of national interest “DETECT-AGING - Degradation Effects on sTructural safEty of Cultural797 heriTAGe constructions through simulation and health monitorING” (Protocol No. 201747Y73L).798 References799 [1] C. Gustafsson, B. Mell´ ar, Research for CULT Committee-Best Practices in Sustainable Management and800 Safeguarding of Cultural Heritage in the EU., European Parliament, 2018.801 [2] European tourism – Trends & Prospects – Quarterly Report Q1/2021., Tech. rep., ETC-European Travel802 Commission (2021).803 [3] T. M. Ferreira, R. Vicente, J. A. R. M. Da Silva, H. Varum, A. Costa, Seismic vulnerability assessment804 of historical urban centres: case study of the old city centre in Seixal, Portugal, Bulletin of Earthquake805 Engineering 11 (5) (2013) 1753–1773.806 [4] M. Villar-Vega, V. Silva, H. Crowley, C. Yepes, N. Tarque, A. B. Acevedo, M. A. Hube, C. D. Gustavo, H. S.807 Mar´ ıa, Development of a fragility model for the residential building stock in South America, Earthquake808 Spectra 33 (2) (2017) 581–604.809 [5] A. Rossi, A. Tertulliani, R. Azzaro, L. Graziani, A. Rovida, A. Maramai, V. Pessina, S. Hailemikael, G. Buf-810 farini, F. Bernardini, The 2016-2017 earthquake sequence in Central Italy: macroseismic survey and damage811 scenario through the EMS-98 intensity assessment, Bulletin of Earthquake Engineering 17 (5) (2019) 2407–812 2431.813 [6] K. Van Breugel, Societal burden and engineering challenges of ageing infrastructure, Procedia Engineering814 171 (2017) 53–63.815 [7] L. Binda, G. Gatti, G. Mangano, C. Poggi, G. S. Landriani, Collapse of the civic tower of Pavia: a survey of816 the materials and structure, Masonry International 6 (1) (1992) 11–20.817 39 [8] J. S. Mitchell, From vibration measurements to condition-based maintenance, Sound and vibration 41 (1)818 (2007) 62–79.819 [9] K. Gkoumas, F. L. Marques Dos Santos, M. van Balen, A. Tsakalidis, A. Ortega Hortelano, M. Grosso,820 G. Haq, F. Pek´ ar, Research and Innovation in Bridge Maintenance, Inspection and Monitoring, Tech. rep.821 (2019).822 [10] P. Cawley, Structural health monitoring: Closing the gap between research and industrial deployment, Struc-823 tural Health Monitoring 17 (5) (2018) 1225–1244.824 [11] C. R. Farrar, S. W. Doebling, D. A. Nix, Vibration-based structural damage identification, Philosophical825 Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences826 359 (1778) (2001) 131–149.827 [12] L. M. Gandham, J. R. Kota, P. Kalapatapu, V. D. K. Pasupuleti, A survey on current heritage structural health828 monitoring practices around the globe., in: Digital Heritage. Progress in Cultural Heritage: Documentation,829 Preservation, and Protection, Springer International Publishing, 2020, pp. 565–576.830 [13] G. Zini, M. Betti, G. Bartoli, A quality-based automated procedure for operational modal analysis, Mechan-831 ical Systems and Signal Processing 164 (2022) 108173.832 [14] M. L. Pecorelli, R. Ceravolo, R. Epicoco, An automatic modal identification procedure for the permanent833 dynamic monitoring of the sanctuary of Vicoforte, International Journal of Architectural Heritage (2018)834 1–15.835 [15] L. F. Ramos, L. Marques, P. B. Lourenc¸o, G. De Roeck, A. Campos-Costa, J. Roque, Monitoring histori-836 cal masonry structures with operational modal analysis: two case studies, Mechanical Systems and Signal837 Processing 24 (5) (2010) 1291–1305.838 [16] F. Ottoni, C. Blasi, Results of a 60-year monitoring system for santa maria del fiore dome in florence,839 International Journal of Architectural Heritage 9 (1) (2015) 7–24.840 [17] M. Mishra, Machine learning techniques for structural health monitoring of heritage buildings: A state-of-841 the-art review and case studies, Journal of Cultural Heritage 47 (2020) 227–245.842 [18] S. Sony, K. Dunphy, A. Sadhu, M. Capretz, A systematic review of convolutional neural network-based843 structural condition assessment techniques, Engineering Structures 226 (2021) 111347.844 [19] C. Scuro, F. Lamonaca, S. Porzio, G. Milani, R. S. Olivito, ´Internet of Things (IoT) for masonry struc-845 tural health monitoring (SHM): Overview and examples of innovative systems, Construction and Building846 Materials 290 (2021) 123092.847 40 [20] G. D. Zhou, T. H. Yi, A summary review of correlations between temperatures and vibration properties of848 long-span bridges, Mathematical Problems in Engineering 2014.849 [21] G. Zonno, R. Aguilar, R. Boroschek, P. B. Lourenc¸o, Analysis of the long and short-term effects of tempera-850 ture and humidity on the structural properties of adobe buildings using continuous monitoring, Engineering851 Structures 196 (2019) 109299.852 [22] R. Ceravolo, G. Coletta, G. Miraglia, F. Palma, Statistical correlation between environmental time series853 and data from long-term monitoring of buildings, Mechanical Systems and Signal Processing 152 (2021)854 107460.855 [23] F. Ubertini, G. Comanducci, N. Cavalagli, A. L. Pisello, A. L. Materazzi, F. Cotana, Environmental effects on856 natural frequencies of the San Pietro bell tower in Perugia, Italy, and their removal for structural performance857 assessment, Mechanical Systems and Signal Processing 82 (2017) 307–322.858 [24] R. M. Azzara, G. De Roeck, M. Girardi, C. Padovani, D. Pellegrini, E. Reynders, The influence of environ-859 mental parameters on the dynamic behaviour of the San Frediano bell tower in Lucca, Engineering Structures860 156 (2018) 175–187.861 [25] C. Gentile, A. Ruccolo, F. Canali, Long-term monitoring for the condition-based structural maintenance of862 the Milan Cathedral, Construction and Building Materials 228 (2019) 117101.863 [26] E. Garc´ ıa-Mac´ ıas, F. Ubertini, Automated operational modal analysis and ambient noise deconvolution inter-864 ferometry for the full structural identification of historic towers: A case study of the Sciri Tower in Perugia,865 Italy, Engineering Structures 215 (2020) 110615.866 [27] E. M. Tronci, M. De Angelis, R. Betti, V. Altomare, Vibration-based structural health monitoring of a RC-867 masonry tower equipped with non-conventional TMD, Engineering Structures 224 (2020) 111212.868 [28] A. Cabboi, C. Gentile, A. Saisi, From continuous vibration monitoring to FEM-based damage assessment:869 application on a stone-masonry tower, Construction and Building Materials 156 (2017) 252–265.870 [29] A. Deraemaeker, K. Worden, A comparison of linear approaches to filter out environmental effects in struc-871 tural health monitoring, Mechanical Systems and Signal Processing 105 (2018) 1–15.872 [30] H. F. Zhou, Y. Q. Ni, J. M. Ko, Eliminating temperature effect in vibration-based structural damage detection,873 Journal of Engineering Mechanics 137 (12) (2011) 785–796.874 [31] A. Entezami, H. Shariatmadar, S. Mariani, Early damage assessment in large-scale structures by innovative875 statistical pattern recognition methods based on time series modeling and novelty detection, Advances in876 Engineering Software 150 (2020) 102923.877 41