scieee AI-readable full text Open interactive document viewer

A Real-Time Electrical Load Forecasting in Jordan Using an Enhanced Evolutionary Feedforward Neural Network

Alhmoud, Lina,Al-Zoubi, Ala´ M.

Abstract

Power system planning and expansion start with forecasting the anticipated future load requirement. Load forecasting is essential for the engineering perspective and a financial perspective. It effectively plays a vital role in the conventional monopolistic operation and electrical utility planning to enhance power system operation, security, stability, minimization of operation cost, and zero emissions. TwoWell-developed cases are discussed here to quantify the benefits of additional models, observation, resolution, data type, and how data are necessary for the perception and evolution of the electrical load forecasting in Jordan. Actual load data for more than a year is obtained from the leading electricity company in Jordan. These cases are based on total daily demand and hourly daily demand. This work’s main aim is for easy and accurate computation of week ahead electrical system load forecasting based on Jordan’s current load measurements. The uncertainties in forecasting have the potential to waste money and resources. This research proposes an optimized multi-layered feed-forward neural network using the recent Grey Wolf Optimizer (GWO). The problem of power forecasting is formulated as a minimization problem. The experimental results are compared with popular optimization methods and show that the proposed method provides very competitive forecasting results.

Full text

sensors Article A Real-Time Electrical Load Forecasting in Jordan Using an Enhanced Evolutionary Feedforward Neural Network Lina Alhmoud 1, Ruba Abu Khurma 2, Ala’ M. Al-Zoubi 2,3 and Ibrahim Aljarah 2,*   Citation: Alhmoud, L.; Abu Khurma, R.; Al-Zoubi, A.M.; Aljarah, I. A Real-Time Electrical Load Forecasting in Jordan Using an Enhanced Evolutionary Feedforward Neural Network. Sensors 2021,21, 6240. https://doi.org/10.3390/s21186240 Academic Editor: Antonino Laudani Received: 16 July 2021 Accepted: 6 September 2021 Published: 17 September 2021 Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. Copyright: © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/). 1Department of Electrical Power Engineering, Faculty of Engineering Technology, Yarmouk University, Irbid 21163, Jordan; [email protected] 2King Abdullah II School for Information Technology, The University of Jordan, Amman 11942, Jordan; [email protected] (R.A.K.); [email protected] or [email protected] (A.M.A.-Z.) 3School of Science, Technology and Engineering, University of Granada, 18011 Granada, Spain *Correspondence: [email protected] Abstract: Power system planning and expansion start with forecasting the anticipated future load requirement. Load forecasting is essential for the engineering perspective and a financial perspective. It effectively plays a vital role in the conventional monopolistic operation and electrical utility planning to enhance power system operation, security, stability, minimization of operation cost, and zero emissions. Two Well-developed cases are discussed here to quantify the benefits of additional models, observation, resolution, data type, and how data are necessary for the perception and evolution of the electrical load forecasting in Jordan. Actual load data for more than a year is obtained from the leading electricity company in Jordan. These cases are based on total daily demand and hourly daily demand. This work’s main aim is for easy and accurate computation of week ahead electrical system load forecasting based on Jordan’s current load measurements. The uncertainties in forecasting have the potential to waste money and resources. This research proposes an optimized multi-layered feed-forward neural network using the recent Grey Wolf Optimizer (GWO). The problem of power forecasting is formulated as a minimization problem. The experimental results are compared with popular optimization methods and show that the proposed method provides very competitive forecasting results. Keywords: artificial neural network; hourly demand; load forecasting; maximum demand; total demand 1. Introduction Power system planning is indispensable. It starts with a forecast of expected future load requirements on both demand and energy. Demand forecasts are used to determine the capacity of generation, transmission, and distribution. Estimating both demand and energy requirements is crucial to effective system planning. A load forecast can help establish the policy for the procurement of capital equipment and fuel. Forecasting plays a significant role in planning and saving in the cost. Further energy forecasts are needed to determine the future of fuel requirements. When the fuel prices soar high, the rate relief to maintain an adequate return rate can also be predicted by load forecasting. Load forecasting supports an electric utility to make essential decisions such as purchasing and generating electrical power, load switching, and infrastructure development. Thus, this study helps to minimize the gap between demand and supply of power to avoid shortage or surplus in the power system. Forecasting is considered a risky business. It is a mechanism of extrapolating the past data into the future using a mathematical formula or gathering the expert’s trends. Load forecasting in a power system is a technique used by the utility that provides the power to predict the energy needed to meet demand and supply equilibrium. It is mainly based on area, location of load, type of load (industrial, commercial and residential) [1–3]. Sensors 2021,21, 6240. https://doi.org/10.3390/s21186240 https://www.mdpi.com/journal/sensors Sensors 2021,21, 6240 2 of 25 The electrical power grid challenges, such as the vulnerability assessment, is a computationally-intensive process; the measurements are noisy, the uncertainty in the operating conditions, and the grid needs to be continually updated. The energy management system manages the operating of the electrical grid within the safe limit. It is automatically adjusted to demand, identify risk, take preventive blackouts action, expedite restoration and buy energy from the neighboring grid or not during the day. However, there is no right way of designing features. The distribution companies face discrepancies between the expected and actual energy production, leading to unbalanced grid energy shortages and surpluses. The lack and excess are costly for utilities as they may cause making energy. Therefore, the utility company must make an informed a balancing decision to minimize costs and operational complications. The more accurately the energy produced from can be predicted. Energy generation must be accurately forecasted to prevent energy shortages and surpluses. Utility companies must be able to make informed grid balancing decisions to minimize cost and operational complications. One reason for these companies’ low revenue is the lack of accurate demand forecast and demand planning. Load forecasting is considered a hot topic across energy companies. Thus it can be defined as the estimation for future load by an industry or utility company. This estimation of future electricity demand both affects the strategic and operational level of decisions in the industry. Precise load forecasting helps the electric utility make commitment decisions, reduce spinning reserve capacity, and schedule the maintenance plan properly. Load forecasting can be used for forecasting the operational assessment to minimize cost and operational effects while maximizing revenues. The main steps to develop a forecast can be summarized as follows: (i) determining the primary use of the forecast; (ii) identifying items; (iii) determining the time horizon; (iv) selecting the forecasting model and validating this model. Forecast accuracy is not an end itself; it improves performance and achieves costsaving and good planning. It is useful in load forecasting to consider the adaption period by adjusting the forecasting process to the right level with the most recent data. It is based on the comparison of the last made forecast and the actual belonging outcome. Accurate forecasting of demand helps in cost minimization. Optimization [ 4 , 5 ] is finding the optimal points (maxima and minima) in a particular system. It involves testing out many different combinations of inputs to determine the resulting outputs. Optimization algorithms are much more sophisticated than enumeration. Optimization theory has custom-made algorithms to find the optimal solution with minimal computation by exploiting knowledge of the model. Optimization techniques are used to find the better and faster optimal design—besides the optimal decision evaluations, proper trade-offs, and non-intuitive analysis. This study sake to develop an automated technique for short-term load forecasting (STLF) using multi-layer perceptron neural network (MLP) [ 6 ]. It provides a quick and accurate prediction of different cases of hourly load for the next seven days at the level of accuracy required by today’s complex and competitive power market. A gray wolf optimizer (GWO) is chosen as one of the algorithms applied to Jordan’s electrical load forecasting system to find the best design, the lowest cost, and the highest efficiency. GWO has proven its impressive performance in a wide range of applications, including engineering [ 7 ], medical [ 4 ] and different machine learning applications [ 8 ]. The primary issue for the widespread usage of GWO in applications is that it has a unique hierarchical population structure. This helped GWO to save the best solutions throughout iterations. Furthermore, GWO has adaptive parameters that make a smooth transition between the exploration and exploitation phases of the optimization process. This indicates the capability of the optimizer to alleviate the entrapment in local minima. To the best of our knowledge, this is the first work on optimized load forecasting using GWO. Innovative system performance, increased system resilience and reliability, cost reduction and environmental productivity are the main criteria for measuring system performance. The requirement is valid and clean data from multiple resources to build a prediction model. Sensors 2021,21, 6240 3 of 25 The rest of this paper is arranged as follows. Section 2summarizes the related work. Section 3introduces the preliminaries that are used in this research. Section 4introduces the data collection process. The proposed forecasting method is addressed in Section 5 . Experiments and results are demonstrated in Section 6. The paper finishes with the conclusion and future work in Section 7. 2. Related Work Forecasting techniques can be divided into two fundamental techniques: quantitative and qualitative [ 9 , 10 ]. Time series [ 11 ], regression methods [ 12 ], moving average [ 13 ], exponential smoothing [ 14 ] and trend projection [ 15 ] are examples of the quantitative techniques. They are used when the situation is stable and historical data exists. Also, it involves mathematical techniques. Whereas the qualitative techniques [ 16 ], such as high-level experts [ 17 ] and Delphi methods [ 18 ]. They are used when the situation is vague and little data exists. They involve intuition experience and sometimes statistical models augment it. STLF for Jordan power system grid based on optimized NN is demonstrated in many studies [ 19 – 21 ]. The authors in [ 19 ], proposed an STLF by adopting the NN in Jordan’s power system. Different optimization methods such as particle swarm optimization (PSO), genetic algorithm (GA), and elephant herding optimization (EHO) were applied to optimize the updated parameters. In this study, the authors computed the error before and after the optimization process was performed. The results proved that the optimization methods based on NN achieved competitive performance for load forecasting. The main information the authors obtained from the study is that a two-layer NN is the best for load forecasting. In [ 20 ], the authors developed a new method based on a rolling stochastic Auto-Regressive Integrated Moving Average with Exogenous (ARIMAX) to minimize the effect of the COVID-19 pandemic on the performance of the load forecasting model. The proposed model tried to enhance the forecast performance by identifying the non-smooth demand nature by suggesting different future demand scenarios based on a probabilistic model. The proposed model achieved better results than the ARIMAX model and Artificial Neural Network (ANN) and reduced the error of forecasting by up to 23.7%. In [ 21 ], a new method was proposed based on NN for LTLF of the Jordanian power system from 2015 to 2029. Two types of feedforward neural networks (FFNN) were adopted; the back-propagation and the radial basis function neural networks; (BPNN) and (RBFNN), respectively. The National Electric Power Company (NEPCO) dataset was used in the training and testing of the proposed NN methods. The performance accuracy of the proposed NN methods was evaluated in terms of the mean square error (MSE) and mean absolute error (MAE). The obtained results were competitive and promising. The proposed NN method can be effectively used for forecasting the annual peak loads of Jordan’s system. In [ 22 ], efficient STLF approaches in machine learning models are investigated in terms of overall execution time and scalability. A combination of three different techniques, extreme gradient boosting (XGB), light gradient boosting (LEGBM), and multilayer perception (MLP), are selected, the performance superiority is approved, including the training time [ 23 ]. A proposed model competes with the traditional ones based on modifying non-parameter kernel-density estimation to validate the prediction intervals and NSGA-II is adopted for multi-objective optimization [ 24 ]. A new STLF proposed technique based on time series and nonlinear relationship of load data hybrid with the multi-temporal spatial scale method [ 25 ]. An implementation of STLF online adaptive recurrent neural network is presented. In this work, the model is updated continuously as new data [ 26 ]. In [ 27 ], optimal electrical load forecasting is presented. A root cause of the economic reduction is discussed based on an insensitive linear-linear cost using asymmetric support vector regression of the data. A Busload forecasting is carried out directly into algorithms, thus in [28]. An enhanced cleaning data setup for quality issues, such as temporary gross errors and random noise. The accuracy is enhanced as a consequence. In [ 29 ], a logistic mixture vector autoregressive model is adopted for LF analysis. It takes into account both the Sensors 2021,21, 6240 4 of 25 pattern variation and pattern-to-pattern. The internal clustering is incorporated to enhance accuracy. STLF analysis based on the transformed data and the statistical machine learning algorithm considering the penetration of renewable energy resources is investigated in [ 30 ], a more resilient and robust grid through accurate electrical load forecasting and using the cutting edge of the machine learning techniques. This study proposed an automated method for STLF based on NN. It provides a quick and accurate prediction of different cases of hourly load for the next seven days at the level of accuracy required by today’s complex and competitive power market. According to the No-Free-Lunch (NFL) theorem [ 31 , 32 ], no optimization algorithm can solve all optimization algorithms with the same level and performance. Therefore, in this study, a GWO is chosen as one of the algorithms applied to Jordan’s electrical load forecasting system to find the best design, the lowest cost, and the highest efficiency. 3. Preliminaries 3.1. Load Forecasting Load forecasting calculates future load consumption based on various historical data and information available as load patterns. The forecasting for different time horizons is essential for additional operations within the utility. These horizons are classified as very short-term load forecasting (VSTLF), STLF, medium-term load forecasting (MTLF), and long-term load forecasting (LTLF). The duration of VSTLF varies from a few minutes to a few hours ahead and mostly 24 h. The major factors affecting this type of LF are weather and special events, such as festivals and special TV programs. It is mainly used for load shading policies, supply and demand gap investigation, power purchasing and selling, switching operation, generation scheduling, and fuel requirements [33]. STLF duration varies from one day to a few weeks ahead. It is essential for planning to start-up and shut down the protocol for generating unit operation, load management, spinning reserve, carrying out load flow, improvement of transmission and distribution system, unit commitment calculation, loss reduction, and a maintenance schedule of the distribution system. MTLF involves a horizon from a few days to a few months ahead; this is preferred for balance sheet calculation and risk management. It suits outage and maintenance planning and load switching operation, renovation and modernization of existing generation plants, calculating the capital cost of different generation options, calculating various operational costs, and calculating power to sell or buying with the neighboring power system. LTLF leads time is measured in months, quarters, or even years. Many factors affect it, such as economic factors, population factors, and renewable integration. It concerns determining the power plant’s future site and capacity and developing the newer ones and the national grid expansion. The LTLF is preferred for carrying out demand-side management, fuel mix decisions, investment decisions in the generation and transmission systems, and preparing the maintenance schedule of generating units. It is worth mentioning that the extended period is better to schedule resources in the marketplace. LTLF is based on the annual trends to ensure that load can be met in the years and decades to forecast regarding transmission line planning and generation planning. Trend analysis in LTLF extends past electricity demand rates into the future using techniques that range from hard-drawn straight lines to complex computer software that produces curves trend analysis. It focuses on the changes in electricity demand and uses them to predict future growth in electricity demand. The advantage of trend analysis is that it is simple, quick, and inexpensive to perform. The disadvantage of the trend forecast is that it produces only the future electricity demand without giving feedback. It does not analyze why electricity demand behaves the way it does [34]. 3.2. STLF It is essential to develop the STLF model, requiring a more straightforward structure and faster speed convergence. Besides, it is necessary to make some explicit assumptions Sensors 2021,21, 6240 5 of 25 to simplify the process of STLF. It starts with collecting and managing the high-quality data on the site of measurement, then using the best archives of weather data from the government agencies. The best high-resolution topography and land cover information can be added, especially in wind and PV solar energy forecasting. Then the best model is picked that fits the data set. After that, use the model and analyze the data and forecast the system. Finally, verification and benchmarking are handled by comparing the forecasted variable to reality. Many factors control accurate load forecasting in power systems: weather influence, time factors, customer classes, economic and environmental class, unforeseeable random events, and historical data. The electrical load has an obvious correlation to weather. Some essential variables are responsible for load fluctuations such as humidity, wind speed, and direction, thunderstorm, fog, snow, rain, global radiation, sunshine, and dew point; of course, not all the weather parameters are the same importance. If the winter is colder than the normal one and the summer, then the electricity demand is also higher—these weather data needed to be available in real-time observation. Besides, refinement to weather inputs could lead to substations cost-saving and more efficient use of resources. For example, climate change affects infrastructure and load integration of renewables such as solar and wind resources availability. The average weather variability is very high and the noise often swamps the climate signal in the LTLF. Climate change is considered a scientific reality and a political minefield. However, variability and uncertainty are intrinsic to weather and the energy consumption relationship and their effects on the power and power markets. Time factors are represented by the day of the week, the hour of the day, and holidays, seasonal variation, daily variation, holidays, and vacation. Besides, there is less demand at midnight because of fewer human activities. Customer load demands can be broadly divided into three groups (industrial, residential and commercial). Whereas the economic factors such as electricity price, population change, and demand-side management. The environmental factors such as service are demographic (rural and urban). Some special events include starting the school year, football matches, and quarantine because of the coronavirus and the beginning of the school year. There are four broad categories for a load: domestic loads such as lighting and fans. It has the most constant annual growth rate and the most seasonal fluctuation. The seasonal variation is because of the widespread use of weather-sensitive devices such as air conditioners and space heating. The industrial loads are considered as base loads; it is little weather dependent variables. The commercial loads, such as shops and electrical appliances used in commercial establishments are characterized by seasonal variation. Agricultural loads: This type of load is required to supply water for irrigation using suitable pumps driven by electric motors. The system’s load is constantly changing; variation is more at the consumer ends than at the substation transformer. There is no such term as “steady-state load”. The electrical data is collected and analyzed based on the actual operating supervisory control and data acquisition (SCADA) and meter readings. Thus it is vital to get clean operational data to understand the actual performance. Indeed, the use of more data improves load forecasting. Hence, utilities should work on expediting and transform the data to represent the system best. It leads to a smooth operation of the grid. The available tribal knowledge is based on past real-life experience. However, the data is always going to be old. Although historical data plays a significant role in load forecasting, management becomes a slave to the historical data and trends rather than the new business reality in the worst scenario. There is no pledge that the conditions in the past will reoccur shortly. It is not reasonable to factor in unique or unexpected events and externalities. Turning a large volume of complete data into actionable information. The data set can be used to make better decisions based on descriptive (what happened?), diagnosis (Why did it happen?), predictive (What will happen? And What should be done?). STLF is usually done 24 h ahead of when the weather forecast for the following day becomes available. The STLF is very critical to the supplier’s utility. It shows how many generators are in operation, which means shut up some units when the forecasted load is Sensors 2021,21, 6240 6 of 25 low and start-up some units when the forecasted load is high. This load comprises four parts: baseload (LB) is the portion of the load that is found to be dependent on overall economic activity and climate conditions for a specified area; weather dependent load (LW) ; particular event load (LC) is the load demand added to special events or a religious and social occasion and the complete random term (LR) such as noise. Hence, the total demand D can be represented as D=LB+LW+LC+LR(1) 4. Data Collection The electrical data is collected and analyzed based on the actual operating supervisory control and data acquisition (SCADA) and meter readings. Thus it is vital to get clean operational data to understand the actual performance. Indeed, the use of more data improves load forecasting. Hence, utilities should expedite and transform the data to represent the system best; this leads to a smooth operation. In modeling load forecast, there are different day type patterns. The user defines the day type for days with the same energy consumption paradigm, such as the national holidays, religious holidays, and social holidays. The load series is complex and exhibits several levels of seasonality. The load depends on the load at the previous hour and simultaneously on the same denomination day. The accumulated connected load is the sum of the continuous rating of the entire loadconsuming apparatus connected to the system. Simultaneously, the system’s maximum demand is the greatest of all demands that have occurred during a specified period (daily, monthly, and yearly). A simple way to save on the peak day includes postponing home appliances until the peak day or peak hour is over. After wrangling these data, it is used to forecast daily power availability. Actual load data for more than a year is obtained from one of the leading electricity companies in Jordan. Weather data is collected from the weather station across Jordan. A new forecasting model is developed that is dynamic and can seem future forecasting downtime. It starts with collecting some data, fitting the model, and then using it to know the forthcoming response’s value. The primary input data set is based on the historical consumption, calendar, day type, weather forecast, and observations. A dimensional reduction is necessary to be considered when the data set is selected. One way is the empirical deduction; it is based on the highly correlated variables and thus redundant, besides these data not correlated with energy consumption. Another way is the principal component analysis. It is based on seeking the maximization of the variance between the dimensions of the data set. Data should not exhibit multicollinearity. STLF is conducted using the load data from 1 January 2019 to 31 December 2019. as a training set. As training set and the target set is 1 January 2020 to 7 January 2020. The load data is recorded every hour. Electrical consumption varies depending on many parameters, seasonality climate, electrical prices, and exceptional events. The scenarios that are typically obtaining a good balance between accuracy and simplicity for selecting the optimal set of input neurons are: 1. Temperature (◦C), T1(k); 2. Hour of the day (00:00/12:00 a.m.–23:00/11:00 p.m.), T2(k); 3. Day type such as workday, weekend and holiday ( − 1 for work day, − 2 for holiday, 0 for Friday and Saturday), T3(k); 4. Day of the week (1/Sunday–7/Saturday), T4(k); 5. Week number in a year (1, 2, . .., 52), T5(k). 6. Month number in a year (1/January, 2/February, . . ., 12/December), T6(k). This chosen structure to build the load forecasting model is the one that gives the best performance in terms of accuracy, reliability, efficiency, simplicity, complete control over power prediction, minimizes the foretasted error, and ensures success based on the trusted partnership industry. Two different cases are studied: hourly daily load and total daily Sensors 2021,21, 6240 7 of 25 load. The total daily load can be defined as the sum of the baseload and weather-dependent components. It is given as in Equation (2): Wtotal(d) = 24 ∑ h=1 W(h,d)(2) 5. Methodology 5.1. Multi-Layer Perceptron Neural Networks (MLP) The artificial neural network is a sub-field of machine learning where the human brain neural network structure inspires the algorithm. the data are collected and trained to recognize the patterns in this data and then predict the output for a new set of similar data [ 35 – 37 ]. The MLP is a well-known type of FNNs. It comprises layers of neurons; these neurons are the core processing units of the network. There are three layers, the input layers that receive the input and the output layers that predict the final output, whereas the hidden layers are located between the two layers. These hidden layers perform most of the computation required by the network. The number of hidden layers depends on the complexity of the problem. Researchers commonly, use a single layer by default. Figure 1 shows a default MLP with input layer compromises n neurons, a single hidden layer compromises mneurons and an output layer compromises kneurons. Figure 1. ANN architecture. The MLP represents a directed connected graph in which each hidden neuron is connected with n connection weight. In addition, a bias weight enters each hidden neuron. Two primary processes are performed inside each hidden neuron: summation and activation. The output of the summation process of neuron j is performed using Equation (3) . After the summation is accomplished, the output is mapped using a particular function called transfer or activation function. The activation function is performed using Equation (4). Sumj= n ∑ i=1 wij ∗ini+bj(3) where wij represents the connection weight between the input iin the input layer and the neuron jin the hidden layer, bjis the bias jto the hidden neuron j. yj=f(sumj)(4) Sensors 2021,21, 6240 8 of 25 where yj is the output neuron j ; j= 1, 2, . . . m ; f is the sigmoid function and computed as in Equation (5). f(sumj) = 1 1+e−sumj(5) After collecting the outputs of all the hidden neurons, the final outputs Yj are computed based on the summation and activation functions as shown in Equations (6) and (7) . Sumj= m ∑ i=1 wij ∗yj+bj(6) where wij represents the connection weight between the hidden neuron i in the hidden layer and the neuron jin the output layer, bjis the bias jto the output neuron j. yj=f(sumj)(7) where Yj is the final output j ; j= 1, 2, . . . k ; f is the same sigmoid function used in Equation (5). 5.2. GWO A metaheuristic is a developed optimization algorithm with a high-level problem independent framework [ 38 – 40 ]. The best solution in the metaheuristic algorithm is found out of all possible solutions of an optimization. GWO is one of the metaheuristic algorithms proposed by Mirjaliali Mohammad and Lewia in 2014. GWO is a well-established swarm intelligence methodology that has been utilized in a wide range of applications with promising achieved performance. The idea of GWO is inspired by the grey wolves’ hierarchy in nature and their strategy in hunting prey. Gray wolf (Canis lupus) is a sizeable canine animal; Its running speed is around 50–60 km/h. The lifespan in the wild is about 6 to 8 years. It belongs to the Canidae biological family of dogs like carnivorans. The weight is around 40 kg (M) and 37 kg (F). The length is approximately (105 cm–160 cm) (M) and (80 cm–85 cm) (F). The height is (40 in–63 in.) (M) and (31 in–33 in) (F). It lived in highly organized packs and is considered one of the most successful animals on earth. It is well known as loyal to the pack members and ability to work together in a pack. The average pack size ranges from 5–12, with different ranks of wolves in a pack (Alpha, Beta, Delta, and Omega). The leader of the pack is Alpha. It is responsible for making decisions about hunting, sleeping places, and time to wake up. The second level is Beta. It is considered the best candidate to be Alpha. Beta helps Alpha in decisions making and other activities such as giving feedback to Alpha. Delta is responsible for any danger facing the pack and providing food. Whereas Omega is the lowest rank in the pack, it plays the scapegoat or victim rule. Other ranks blame it for their mistakes or faults. Over that, it is the last one allowed to eat. GWO algorithm mimics the hunting mechanism and leadership of the gray wolves. The optimization mechanism is based on searching for the prey, tracking, chasing, and approaching the prey. Then, pursuing, encircling, and harassing the prey. Finally, attaching the prey. Whitetail, mule deer, moose, and caribou are considered the main prey and the desired target for the gray wolf. Briefly, GWO arranges the wolves in the pack based on their fitness into four levels: α is the best candidate solution found so far, β the second-best candidate solution found so far, δ is the third-best candidate solution found so far, and ω are the remaining solutions in the pack (see Figure 2). The hunting behavior of wolves is modeled by emulating two processes: encircling prey and then hunting it. Sensors 2021,21, 6240 9 of 25 A3 C3 A2 C2 A1 C1 Beta Wolf (second best solution ) Pray (Possible solution ) Attack (Move toward best solution ) Delta Wolf (Third best solution ) Aloha Wolf ( Best solution ) Figure 2. Illustration of the position update strategy for ω wolf based on the position of α and βleaders. 5.2.1. Encircling Prey The distance between each attacking wolf and the prey can be formulated as in Equation (8). −→ D=|−→ C .−→ XP(t)−−→ X(t)|(8) −→ C=2−→ r2(9) where −→ XP(t) represents the vector of the prey’s position in the search space. −→ X ( t ) represents the vector of a wolf’s position in the search space, and t is the current iteration of the optimization process. C is calculated as in Equation (9), and −→ r2 is a vector in the interval [0, 1]. 5.2.2. Hunting Prey An attacking wolf changes its position and becomes closer to prey to hunt it. Based on the distance between a wolf and prey as computed in Equation (8), the next position of a wolf is formulated as in Equation (10). −→ X(t+1) = −→ XP(t)−−→ A .−→ D (10) −→ A=2−→ a .−→ r1−−→ a (11) where −→ a linearly decreases from 2 to 0 over the iterations, and r2 is a random vector in the range [0, 1]. According to the natural wolves hierarchy in the pack, the wolves in the ω group have less knowledge in determining the position of the prey compared with the best three wolves α , β , and δ . Therefore, the distances between each wolf in the pack and the first three best wolves are computed as in Equation (12). −→ Dα=|−→ C1.−→ Xα−−→ X| −→ Dβ=|−→ C2.−→ Xβ−−→ X| −→ Dδ=|−→ C3.−→ Xδ−−→ X| (12) Sensors 2021,21, 6240 16 of 25 0 20 40 60 80 100 120 Sample Index 4 4.5 5 5.5 6 6.5 104LR Error Anylsis Actual Estimate 0 20 40 60 80 100 120 Sample Index -1.5 -1 -0.5 0 0.5 1 1.5 104MSE = 27063663.4787, RMSE = 5202.2748 Error Error Mean = 1307.4441, Error St.D. = 5056.4132 -1.5 -1 -0.5 0 0.5 1 1.5 2 Sample Index 104 0 1 2 3 4 5 6 7 Figure 8. Error analysis of the total daily load consumption with LR best results. 6.3.2. A Comparison between fNN-GWO and Other Meta-Heuristics The comparison of fNN-GWO and other meta-heuristics for hourly daily and total daily load consumption is presented in this subsection. Table 5illustrates the results of fNN-GWO and other meta-heuristics for the hourly daily load consumption. As shown, the fNN-GWO gained the best results in all measures, followed by fNN-WOA, fNN-GA, fNN- PSO, fNN-ACO, fNN-ES, and fNN-WOA, respectively. The difference between fNN-GWO and the nearest meta-heuristic (fNN-WOA) were 173,811.71, 11,069.45, 167.11, 277.91, and 206.27 for MSE, ED, MAE, and RMSE, respectively. The error analysis of the hourly daily load consumption for fNN-GWO, fNN-GA, fNN-PSO, fNN-ACO, fNN-ES, and fNN-WOA methods can be found in Figures 9–14, respectively. Table 5. A comparison between fNN-GWO error forecasting results for hourly daily load consumption, and other metaheuristics methods. Algorithms MSE STD ED STD MAE STD RMSE STD fNN-GWO 77,611.56 11,053.10 14,914.43 1096.01 221.28 17.01 277.91 20.42 fNN-GA 52,6763.24 373,468.90 36,670.28 13,839.10 538.75 195.35 683.31 257.88 fNN-PSO 916,129.55 311,586.14 50,560.75 9548.93 762.81 146.94 942.14 177.93 fNN-ACO 5,453,738.12 3,280,577.19 119,974.85 38,192.50 1873.29 645.70 2235.60 711.68 fNN-ES 3,990,513.26 2,141,128.91 104,027.87 27,302.45 1574.91 451.81 1938.44 508.75 fNN-WOA 251,423.27 153,157.68 25,983.85 7374.03 388.31 107.99 484.18 137.41 Sensors 2021,21, 6240 17 of 25 0 500 1000 1500 2000 2500 3000 Sample Index 0 500 1000 1500 2000 2500 3000 3500 fNN-GWO Error Anylsis Actual Estimate 0 500 1000 1500 2000 2500 3000 Sample Index -2000 -1500 -1000 -500 0 500 1000 MSE = 54636.3753, RMSE = 233.7443 Error Error Mean = 65.7339, Error St.D. = 224.35 -1500 -1000 -500 0 500 1000 Sample Index 0 50 100 150 200 250 300 Figure 9. Error analysis of the hourly daily load consumption with fNN-GWO best results. 0 500 1000 1500 2000 2500 3000 Sample Index 0 500 1000 1500 2000 2500 3000 3500 fNN-GA Error Anylsis Actual Estimate 0 500 1000 1500 2000 2500 3000 Sample Index -2000 -1500 -1000 -500 0 500 1000 1500 MSE = 164886.3853, RMSE = 406.062 Error Error Mean = 92.2037, Error St.D. = 395.5239 -1500 -1000 -500 0 500 1000 Sample Index 0 50 100 150 200 Figure 10. Error analysis of the hourly daily load consumption with fNN-GA best results. Sensors 2021,21, 6240 18 of 25 0 500 1000 1500 2000 2500 3000 Sample Index 0 500 1000 1500 2000 2500 3000 3500 fNN-PSO Error Anylsis Actual Estimate 0 500 1000 1500 2000 2500 3000 Sample Index -2000 -1500 -1000 -500 0 500 1000 1500 MSE = 342859.403, RMSE = 585.542 Error Error Mean = 409.9845, Error St.D. = 418.1302 -1500 -1000 -500 0 500 1000 1500 2000 Sample Index 0 50 100 150 200 Figure 11. Error analysis of the hourly daily load consumption with fNN-PSO best results. 0 500 1000 1500 2000 2500 3000 Sample Index -1000 0 1000 2000 3000 4000 5000 6000 7000 fNN-ACO Error Anylsis Actual Estimate 0 500 1000 1500 2000 2500 3000 Sample Index -5000 -4000 -3000 -2000 -1000 0 1000 2000 3000 MSE = 1715762.5409, RMSE = 1309.8712 Error Error Mean = -878.0097, Error St.D. = 972.2087 -4000 -3000 -2000 -1000 0 1000 2000 Sample Index 0 50 100 150 200 250 Figure 12. Error analysis of the hourly daily load consumption with fNN-ACO best results. Sensors 2021,21, 6240 19 of 25 0 500 1000 1500 2000 2500 3000 Sample Index -1000 0 1000 2000 3000 4000 5000 6000 7000 fNN-ES Error Anylsis Actual Estimate 0 500 1000 1500 2000 2500 3000 Sample Index -5000 -4000 -3000 -2000 -1000 0 1000 2000 3000 MSE = 1851996.849, RMSE = 1360.8809 Error Error Mean = -130.2586, Error St.D. = 1354.8679 -4000 -3000 -2000 -1000 0 1000 2000 3000 4000 Sample Index 0 50 100 150 200 Figure 13. Error analysis of the hourly daily load consumption with fNN-ES best results. 0 500 1000 1500 2000 2500 3000 Sample Index 0 500 1000 1500 2000 2500 3000 3500 fNN-WOA Error Anylsis Actual Estimate 0 500 1000 1500 2000 2500 3000 Sample Index -2000 -1500 -1000 -500 0 500 1000 1500 MSE = 123507.3554, RMSE = 351.4361 Error Error Mean = 83.8569, Error St.D. = 341.3441 -1500 -1000 -500 0 500 1000 Sample Index 0 50 100 150 200 250 Figure 14. Error analysis of the hourly daily load consumption with fNN-WOA best results. The results of the total daily load consumption are portrayed in Table 6. Like previous experiments, the fNN-GWO exceeds the other meta-heuristic algorithms with all measures, followed by, fNN-GA, fNN-PSO, fNN-ACO, fNN-ES, and fNN-WOA. The difference between fNN-GWO and the closet one (fNN-GA) for MSE, ED, MAE, and RMSE were Sensors 2021,21, 6240 20 of 25 5,924,502.24, 6709.77, 391.91, and 612.52, respectively. Figures 15–20 describes the best run for fNN-GWO, fNN-GA, fNN-PSO, fNN-ACO, fNN-ES, and fNN-WOA, respectively. The overall experiments show the superiority of fNN-GWO compared with LR and other meta-heuristic algorithms for prediction and forecasting the load consumption of both hourly and total daily. Table 6. A comparison between fNN-GWO error forecasting results for total daily load consumption, and other metaheuristics methods. Algorithms MSE STD ED STD MAE STD RMSE STD fNN-GWO 1,860,1703.82 3,639,488.12 47,045.26 4588.44 3672.95 382.96 4294.62 418.87 fNN-GA 24,526,206.02 7,740,171.85 53,754.97 7713.47 4064.86 574.74 4907.14 704.14 fNN-PSO 43,950,581.91 13,230,479.06 71,831.02 11,273.08 5284.14 1019.42 6557.25 1029.09 fNN-ACO 170,763,987.82 125,293,682.53 135,044.06 50,053.09 10,263.39 4254.05 12,327.78 4569.20 fNN-ES 129,578,577.48 64,691,684.36 120,956.12 31,955.64 8753.54 2731.52 11,041.73 2917.14 fNN-WOA 30,921,885.96 18,015,693.11 59,131.57 15,423.04 4446.06 1085.71 5397.95 1407.92 0 20 40 60 80 100 120 Sample Index 4 4.5 5 5.5 6 6.5 104fNN-GWO Error Anylsis Actual Estimate 0 20 40 60 80 100 120 Sample Index -1 -0.5 0 0.5 1 1.5 104MSE = 18539261.199, RMSE = 4305.7242 Error Error Mean = 1553.1971, Error St.D. = 4032.6616 -1.5 -1 -0.5 0 0.5 1 1.5 Sample Index 104 0 1 2 3 4 5 6 7 8 Figure 15. Error analysis of the total daily load consumption with fNN-GWO best results. Sensors 2021,21, 6240 21 of 25 0 20 40 60 80 100 120 Sample Index 4 4.5 5 5.5 6 6.5 104fNN-GA Error Anylsis Actual Estimate 0 20 40 60 80 100 120 Sample Index -1.5 -1 -0.5 0 0.5 1104MSE = 18207397.0807, RMSE = 4267.0127 Error Error Mean = 1623.8517, Error St.D. = 3962.4926 -1 -0.5 0 0.5 1 1.5 Sample Index 104 0 2 4 6 8 10 Figure 16. Error analysis of the total daily load consumption with fNN-GA best results. 0 20 40 60 80 100 120 Sample Index 4 4.5 5 5.5 6 6.5 7104fNN-PSO Error Anylsis Actual Estimate 0 20 40 60 80 100 120 Sample Index -1.5 -1 -0.5 0 0.5 1104MSE = 15356133.9539, RMSE = 3918.6903 Error Error Mean = -59.0968, Error St.D. = 3934.6735 -1.5 -1 -0.5 0 0.5 1 1.5 Sample Index 104 0 1 2 3 4 5 6 7 8 Figure 17. Error analysis of the total daily load consumption with fNN-PSO best results. Sensors 2021,21, 6240 22 of 25 0 20 40 60 80 100 120 Sample Index 3 3.5 4 4.5 5 5.5 6 6.5 104fNN-ACO Error Anylsis Actual Estimate 0 20 40 60 80 100 120 Sample Index -1 -0.5 0 0.5 1 1.5 2104MSE = 39591597.2579, RMSE = 6292.1854 Error Error Mean = 4541.8118, Error St.D. = 4372.9739 -1 -0.5 0 0.5 1 1.5 2 Sample Index 104 0 2 4 6 8 10 Figure 18. Error analysis of the total daily load consumption with fNN-ACO best results. 0 20 40 60 80 100 120 Sample Index 4 4.5 5 5.5 6 6.5 104fNN-ES Error Anylsis Actual Estimate 0 20 40 60 80 100 120 Sample Index -1.5 -1 -0.5 0 0.5 1 1.5 104MSE = 28279782.834, RMSE = 5317.8739 Error Error Mean = 97.1601, Error St.D. = 5339.2798 -2 -1.5 -1 -0.5 0 0.5 1 1.5 2 Sample Index 104 0 2 4 6 8 10 Figure 19. Error analysis of the total daily load consumption with fNN-ES best results. Sensors 2021,21, 6240 23 of 25 0 20 40 60 80 100 120 Sample Index 4 4.5 5 5.5 6 6.5 104fNN-WOA Error Anylsis Actual Estimate 0 20 40 60 80 100 120 Sample Index -1 -0.5 0 0.5 1104MSE = 12352976.4742, RMSE = 3514.6801 Error Error Mean = -52.7157, Error St.D. = 3529.0198 -1 -0.5 0 0.5 1 1.5 Sample Index 104 0 1 2 3 4 5 6 7 Figure 20. Error analysis of the total daily load consumption with fNN-WOA best results. 7. Conclusions Forecasting is a risky art. However, it is needed for better future planning. Electric load forecasting is the science of the utility company’s pre-most economical amount of electric power. It should be timely, as accurate as possible, reliable, and in some meaningful units. This study helps minimize the gap between the demand and the supply of power to avoid a shortage of surplus in the power supply. Enhanced planning, optimized operation, improved forecasting, increased efficiency, and reduced cost are considered the main goals of the electrical power system operator. This research proposed an optimized multi-layered feed-forward neural network using the recent Grey Wolf Optimizer (GWO). The problem of power forecasting is formulated as an optimization problem. The experimental results are compared with popular optimization methods and show that the proposed method provides very competitive forecasting results. In the future work of forecasting studies, it needs to include regulator changes and reliability standards. One of the significant challenges in load forecasting studies is the range of planned actions or things expected to occur besides the lack of data science. Author Contributions: Conceptualization, L.A. and I.A.; Data curation, L.A.; Formal analysis, L.A.; Funding acquisition, L.A.; Investigation, R.A.K., A.M.A.-Z. and I.A.; Methodology, L.A., R.A.K. and I.A.; Project administration, I.A.; Resources, A.M.A.-Z.; Supervision, I.A.; Validation, R.A.K. and A.M.A.-Z.; Visualization, I.A.; Writing—review & editing, L.A., R.A.K., A.M.A.-Z. and I.A. All authors have read and agreed to the published version of the manuscript. Funding: This research received no external funding. Institutional Review Board Statement: Not applicable. Informed Consent Statement: Not applicable. Conflicts of Interest: The authors declare no conflict of interest. Sensors 2021,21, 6240 24 of 25 Abbreviations The following abbreviations are used in this manuscript: GWO Grey Wolf Optimizer STLF short-term load forecasting PSO Particle swarm optimization GA Genetic algorithm EHO Elephant Herding Optimization NN Neural Network FFNN Feed Forward Neural Networks RBFNN Radial Basis Function Neural Networks MSE Mean Square Error MAE Mean Absolute Error kNN k-Nearest Neighbors XGB eXtreme Gradient Boosting LGBM Light Gradient Boosting MLP Multilayer Perception NFL No-Free-Lunch VSTLF Very Short-Term Load Forecasting MTLF Medium-Term Load Forecasting LTLF Long-Term Load Forecasting References 1. Phuangpornpitak, N.; Prommee, W. A study of load demand forecasting models in electric power system operation and planning. GMSARN Int. J. 2016,10, 19–24. 2. Feinberg, E.A.; Genethliou, D. Load forecasting. In Applied Mathematics for Restructured Electric Power Systems; Springer: Boston, MA, USA, 2005; pp. 269–285. 3. Park, D.C.; El-Sharkawi, M.A.; Marks, R.J.; Atlas, L.E.; Damborg, M.J. Electric load forecasting using an artificial neural network. IEEE Trans. Power Syst. 1991,6, 442–449. [CrossRef] 4. Sathiyabhama, B.; Kumar, S.U.; Jayanthi, J.; Sathiya, T.; Ilavarasi, A.K.; Yuvarajan, V.; Gopikrishna, K. A novel feature selection framework based on grey wolf optimizer for mammogram image analysis. Neural Comput. Appl. 2021, 1–20. [CrossRef] 5. Faris, H.; Aljarah, I.; Mirjalili, S. Improved monarch butterfly optimization for unconstrained global search and neural network training. Appl. Intell. 2018,48, 445–464. [CrossRef] 6. Zhang, J.; Wei, Y.-M.; Li, D.; Tan, Z.; Zhou, J. Short term electricity load forecasting using a hybrid model. Energy 2018 ,158, 774–781. [CrossRef] 7. Nadimi-Shahraki, M.H.; Taghian, S.; Mirjalili, S. An improved grey wolf optimizer for solving engineering problems. Expert Syst. Appl. 2020,166, 113917. [CrossRef] 8. Tapia, D.; Crawford, B.; Soto, R.; Palma, W.; Lemus-Romani, J.; Cisternas-Caneo, F.; Castillo, M.; Becerra-Rozas, M.; Paredes, F.; Misra, S. Embedding Q-Learning in the selection of metaheuristic operators: The enhanced binary grey wolf optimizer case. In Proceedings of the 2021 IEEE International Conference on Automation/XXIV Congress of the Chilean Association of Automatic Control (ICA-ACCA), Valparaíso, Chile, 22–26 March 2021. 9. Ivanov, D.; Tsipoulanidis, A.; Schönberger, J. Demand Forecasting. In Global Supply Chain and Operations Management; Springer: Cham, Switzerland, 2017; pp. 301–315. 10. Kuster, C.; Rezgui, Y.; Mourshed, M. Electrical load forecasting models: A critical systematic review. Sustain. Cities Soc. 2017 ,35, 257–270. [CrossRef] 11. Maldonado, S.; González, A.; Crone, S. Automatic time series analysis for electric load forecasting via support vector regression. Appl. Soft Comput. 2019,83, 105616. [CrossRef] 12. Takeda, H.; Tamura, Y.; Sato, S. Using the ensemble Kalman filter for electricity load forecasting and analysis. Energy 2016 ,104, 184–198. [CrossRef] 13. Arora, S.; Taylor, J.W. Rule-based autoregressive moving average models for forecasting load on special days: A case study for France. Eur. J. Oper. Res. 2018,266, 259–268. [CrossRef] 14. Rendon-Sanchez, J.F.; de Menezes, L.M. Structural combination of seasonal exponential smoothing forecasts applied to load forecasting. Eur. J. Oper. Res. 2019,275, 916–924. [CrossRef] 15. Lindberg, K.; Seljom, P.; Madsen, H.; Fischer, D.; Korpås, M. Long-term electricity load forecasting: Current and future trends. Util. Policy 2019,58, 102–119. [CrossRef] 16. Hong, T.; Fan, S. Probabilistic electric load forecasting: A tutorial review. Int. J. Forecast. 2016,32, 914–938. [CrossRef] 17. Goehry, B.; Goude, Y.; Massart, P.; Poggi, J.-M. Aggregation of Multi-Scale Experts for Bottom-Up Load Forecasting. IEEE Trans. Smart Grid 2019,11, 1895–1904. [CrossRef] Sensors 2021,21, 6240 25 of 25 18. Kloker, S.; Straub, T.; Weinhardt, C. Designing a crowd forecasting tool to combine prediction markets and real-time Delphi. In Proceedings of the International Conference on Design Science Research in Information System and Technology, Karlsruhe, Germany, 30 May–1 June 2017; Springer: Cham, Switzerland, 2017; pp. 468–473. 19. Alhmoud, L.; Nawafleh, Q. Short-term load forecasting for Jordan’s Power System Using Neural Network based Different. In Proceedings of the 2019 IEEE International Conference on Environment and Electrical Engineering and 2019 IEEE Industrial and Commercial Power Systems Europe (EEEIC/I&CPS Europe), Genova, Italy, 11–14 June 2019; pp. 1–6. 20. Alasali, F.; Nusair, K.; Alhmoud, L.; Zarour, E. Impact of the COVID-19 Pandemic on Electricity Demand and Load Forecasting. Sustainability 2021,13, 1435. [CrossRef] 21. Feilat, E.A.; Talal Al-Sha’abi, D.; Mo-mani, M.A. Long-term load forecasting using neural network approach for Jordan’s power system. Eng. Press. 2017,1, 43–50. EngPress-1-108. 22. Zainab, A.; Syed, D.; Ghrayeb, A.; Abu-Rub, H.; Refaat, S.S.; Houchati, M.; Lopez, S.B. A multiprocessing-based sensitivity analysis of machine learning algorithms for load forecasting of electric power distribution system. IEEE Access 2021 ,9, 31684–31694. [CrossRef] 23. Massaoudi, M.; Refaat, S.S.; Chihi, I.; Trabelsi, M.; Oueslati, F.S.; Abu-Rub, H. A novel stacked generalization ensemble-based hybrid LGBM-XGB-MLP model for Short-Term Load Forecasting. Energy 2021,214, 118874. [CrossRef] 24. Dong, Y.; Ma, X.; Fu, T. Electrical load forecasting: A deep learning approach based on K-nearest neighbors. Appl. Soft Comput. 2021,99, 106900. [CrossRef] 25. Yin, L.; Xie, J. Multi-temporal-spatial-scale temporal convolution network for short-term load forecasting of power systems. Appl. Energy 2021,283, 116328. [CrossRef] 26. Fekri, M.N.; Patel, H.; Grolinger, K.; Sharma, V. Deep learning for load forecasting with smart meter data: Online Adaptive Recurrent Neural Network. Appl. Energy 2021,282, 116177. [CrossRef] 27. Wu, J.; Wang, Y.G.; Tian, Y.C.; Burrage, K.; Cao, T. Support vector regression with asymmetric loss for optimal electric load forecasting. Energy 2021,223, 119969. [CrossRef] 28. Li, Z.; Liu, J.; Lin, Y.; Wang, F. Grid-Constrained Data Cleansing Method for Enhanced Bus Load Forecasting. IEEE Trans. Instrum. Meas. 2021,70, 1–10. 29. Jeong, D.; Park, C.; Ko, Y.M. Short-term electric load forecasting for buildings using logistic mixture vector autoregressive model with curve registration. Appl. Energy 2021,282, 116249. [CrossRef] 30. Andriopoulos, N.; Magklaras, A.; Birbas, A.; Papalexopoulos, A.; Valouxis, C.; Daskalaki, S.; Papaioannou, G.P. Short Term Electric Load Forecasting Based on Data Transformation and Statistical Machine Learning. Appl. Sci. 2021,11, 158. [CrossRef] 31. Ho, Y.; Pepyne, D. Simple Explanation of the No-Free-Lunch Theorem and Its Implications. J. Optim. Theory Appl. 2002 ,115, 549–570. [CrossRef] 32. Faris, H.; Aljarah, I.; Alqatawna, J.F. Optimizing feedforward neural networks using krill herd algorithm for e-mail spam detection. In Proceedings of the 2015 IEEE Jordan Conference on Applied Electrical Engineering and Computing Technologies (AEECT); Amman, Jordan, 3–5 November 2015; pp. 1–5. 33. Li, B.; Zhang, J.; He, Y.; Wang, Y. Short-term load-forecasting method based on wavelet decomposition with second-order gray neural network model combined with ADF test. IEEE Access 2017,5, 16324–16331. [CrossRef] 34. Bianchi, F.M.; De Santis, E.; Rizzi, A.; Sadeghian, A. Short-term electric load forecasting using echo state networks and PCA decomposition. IEEE Access 2015,3, 1931–1943. [CrossRef] 35. Mirjalili, S.; Aljarah, I.; Mafarja, M.; Heidari, A.A.; Faris, H. Grey Wolf Optimizer: Theory, Literature Review, and Application in Computational Fluid Dynamics Problems. In Nature-Inspired Optimizers; Mirjalili, S., Song Dong, J., Lewis, A., Eds.; Studies in Computational Intelligence; Springer: Cham, Switzerland, 2020; Volume 811. [CrossRef] 36. Faris, H.; Aljarah, I.; Mirjalili, S. Training feedforward neural networks using multi-verse optimizer for binary classification problems. Appl. Intell. 2016,45, 322–332. [CrossRef] 37. Faris, H.; Aljarah, I.; Al-Madi, N.; Mirjalili, S. Optimizing the learning process of feedforward neural networks using lightning search algorithm. Int. J. Artif. Intell. Tools 2016,25, 1650033. [CrossRef] 38. Khurma, R.A.; Aljarah, I.; Sharieh, A.; Mirjalili, S. Evolopy-fs: An open-source nature-inspired optimization framework in python for feature selection. In Evolutionary Machine Learning Techniques; Springer: Singapore, 2020; pp. 131–173. 39. Abu Khurma, R.; Aljarah, I.; Sharieh, A. A Simultaneous Moth Flame Optimizer Feature Selection Approach Based on Levy Flight and Selection Operators for Medical Diagnosis. Arab. J. Sci. Eng. 2021,46, 8415–8440. [CrossRef] 40. Abu Khurmaa, R.; Aljarah, I.; Sharieh, A. An intelligent feature selection approach based on moth flame optimization for medical diagnosis. Neural Comput. Appl. 2020,33, 7165–7204. [CrossRef] 41. Faris, H.; Aljarah, I.; Al-Betar, M.A.; Mirjalili, S. Grey wolf optimizer: A review of recent variants and applications. Neural Comput. Appl. 2018,30, 413–435. [CrossRef] 42. Alazab, M.; Awajan, A.; Mesleh, A. COVID-19 prediction and detection using deep learning. Int. J. Comput. Inf. Syst. Ind. Manag. Appl. 2020,12, 168-181. 43. Aljarah, I.; Mafarja, M.; Heidari, A.A.; Faris, H.; Mirjalili, S. Multi-verse optimizer: theory, literature review, and application in data clustering. In Nature-Inspired Optimizers; Springer: Cham, Switzerland, 2020; pp. 123–141. 44. Faris, H.; Mirjalili, S.; Aljarah, I. Automatic selection of hidden neurons and weights in neural networks using grey wolf optimizer based on a hybrid encoding scheme. Int. J. Mach. Learn. Cybern. 2019,10, 2901–2920. [CrossRef]