scieee AI-readable full text Open interactive document viewer

Compact Modeling of Two-Dimensional Field-Effect Biosensors

Pasadas Cantos, Francisco,El Grour, Tarek,González Marín, Enrique,Medina Rull, Alberto,Toral López, Alejandro,Cuesta López, Juan,García Ruiz, Francisco Javier,El Mir, Lassad,Godoy Medina, Andrés

Abstract

Spanish Government MCIN/AEI/10.13039/501100011033 through the projects PID2020-116518GB-I00 and TED2021-129769B-I00 (MCIU/AEI/FEDER-UE)

Full text

Citation: Pasadas, F.; El Grour, T.; G. Marin, E.; Medina-Rull, A.; Toral-Lopez, A.; Cuesta-Lopez, J.; G. Ruiz, F.; El Mir, L.; Godoy, A. Compact Modeling of Two-Dimensional Field-Effect Biosensors. Sensors 2023,23, 1840. https://doi.org/10.3390/s23041840 Academic Editor: Antonio Di Bartolomeo Received: 20 January 2023 Revised: 1 February 2023 Accepted: 1 February 2023 Published: 7 February 2023 Copyright: © 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/). sensors Article Compact Modeling of Two-Dimensional Field-Effect Biosensors Francisco Pasadas 1,* , Tarek El Grour 2,*, Enrique G. Marin 1, Alberto Medina-Rull 1, Alejandro Toral-Lopez 1, Juan Cuesta-Lopez 1, Francisco G. Ruiz 1, Lassaad El Mir 2and Andrés Godoy 1,* 1 Pervasive Electronics Advanced Research Laboratory (PEARL), Departamento de Electrónica y Tecnología de Computadores, Universidad de Granada, 18071 Granada, Spain 2Laboratory of Physics of Materials and Nanomaterials Applied at Environment (LaPhyMNE) LR05ES14, Faculty of Sciences of Gabes, Gabes University, Erriadh City, Zrig, 6072 Gabes, Tunisia *Correspondence: [email protected] (F.P.); elgrour[email protected] (T.E.G.); [email protected] (A.G.) Abstract: A compact model able to predict the electrical read-out of field-effect biosensors based on two-dimensional (2D) semiconductors is introduced. It comprises the analytical description of the electrostatics including the charge density in the 2D semiconductor, the site-binding modeling of the barrier oxide surface charge, and the Stern layer plus an ion-permeable membrane, all coupled with the carrier transport inside the biosensor and solved by making use of the Donnan potential inside the ion-permeable membrane formed by charged macromolecules. This electrostatics and transport description account for the main surface-related physical and chemical processes that impact the biosensor electrical performance, including the transport along the low-dimensional channel in the diffusive regime, electrolyte screening, and the impact of biological charges. The model is implemented in Verilog-A and can be employed on standard circuit design tools. The theoretical predictions obtained with the model are validated against measurements of a MoS 2 field-effect biosensor for streptavidin detection showing excellent agreement in all operation regimes and leading the way for the circuit-level simulation of biosensors based on 2D semiconductors. Keywords: 2D; biosensor; field-effect transistor; immunosensor; modeling; MoS 2 ; sensor; TMD; two-dimensional; Verilog-A 1. Introduction The rapid detection and continuous monitoring of biological and chemical compounds are of utmost interest for medical purposes, including, e.g., point-of-care solutions, drug detection, genomics, etc. [ 1 – 6 ]. The chemical and electrical sensors employed in the detection, conventionally grouped under the common term of biosensors, can be broadly categorized into two classes: label-based sensors and label-free sensors. The former group is characterized by processing the sample (looking for the detection of the target molecules) via measurable parameters, such as fluorescence or colorimetry, employing elaborated procedures and additional equipment that precludes its use for real-time applications. The latter is not conditioned by external facilities or human intervention and enables continuous monitoring and detection. Among them, biosensors based on field-effect transistors (BioFETs) are expected to play a leading role in the field, as they enable the direct integration of the detection of biochemical compounds, the signal acquisition, and the conditioning modules in a single system, reducing the cost, the power consumption, and enabling a portable platform for fast and steady sensing. In this particular biosensing niche, emerging two-dimensional materials (2DMs)-based field-effect transistors (FETs) constitute an exceptional technological alternative for sensing due to their promising physical and chemical properties. Specifically, their optimum surface- to-volume ratio enhances the electrostatic coupling leading to exceptional sensitivity to the target substances. Additionally, 2D sensors can also be fabricated in a miniaturized size by leveraging the ultimate thickness scalability of 2DMs and show the capability to enhance Sensors 2023,23, 1840. https://doi.org/10.3390/s23041840 https://www.mdpi.com/journal/sensors Sensors 2023,23, 1840 2 of 16 chemical sensitivity via surface functionalization, inherent flexibility, and great mechanical strength [ 7 – 12 ] that redounds in their suitability for the nascent flexible, portable, and/or wearable nanotechnology [ 13 , 14 ]. Furthermore, 2DMs present additional outstanding physical and chemical properties such as amphiphilicity, anisotropic thermal conductivity, anti-reflectance, and corrosion resistance [ 15 ]. More importantly, many of these 2DMs, such as graphene and some transition metal dichalcogenides (TMDs), are biocompatible with human body tissues and environmentally friendly [ 16 , 17 ]. In addition to this exceptional collection of properties, 2DM technology is compatible with back-end-of-line processing and thin-film technology [ 18 ], enabling the hybrid integration of 2DMs with conventional technologies [ 19 ]. These features will allow the development of advanced systems formed by the combination of highly sensitive 2D material-based sensors with signal processing and transmission stages based on mature technologies, which will be of fundamental importance for the deployment of the Internet of Things (IoT) platform. However, before the technology readiness level for commercial use of these sensors is reached, many requirements should be considered. Among them, the selectivity issue should be the primary consideration. Ions or molecule selectivity depends on the electrical and chemical properties of the 2DMs and of the ions/molecules themselves. Particularly, 2DMs can interact with target ions/molecules by two distinctive mechanisms: physisorption and chemisorption. Physisorption refers to the interaction between the ions or molecules and the surface of 2DMs without any covalent bonding, while chemisorption takes place when covalent bonds are created between the ions or molecules and the surface of 2DMs. Non-covalent interactions are preferred for biosensing because they result in quick response and fast recovery. The nature of the 2DM-ion/molecule interaction can be adjusted by placing a barrier, in the form of an oxide, between the chemical compounds and the 2DM channel. The presence/absence of the barrier categorize BioFET sensing interfaces into an electrolyte–insulator–semiconductor (EIS) or electrolyte–semiconductor (ES) [ 20 ]. The barrier in an EIS BioFET (placed between the electrolyte and the semiconductor) can be functionalized with the aim of attaching receptor agents able to capture the target molecules [ 2 , 21 ] and prevents possible reactions between the ions contained in the solution and the semiconductor surface, i.e., the possible chemisorption, but it reduces the electrical coupling between the device and the molecules [ 20 ]. In addition, most of the materials employed as insulator barriers have a hydrophilic nature that hinders their functionalization and reduces the efficiency of the bindings [ 22 ]. In contrast, ES BioFETs leave the semiconductor channel in direct contact with the electrolyte, taking advantage of the hydrophobicity of some semiconductors to create an intrinsic barrier; 2DMs such as molybdenum disulfide (MoS 2 ), reduced graphene oxide (r-GO), and graphene show the hydrophobic behavior, becoming good candidates to be employed in ES BioFETs [22–24]. A wide variety of 2DMs-based BioFETs have already been successfully fabricated and tested, and their operating principles are subject of intense research. Graphene and TMDs, namely MoS 2 and tungsten diselenide (WSe 2 ), lead the race, demonstrating high sensitivity to external stimuli, such as those originating from antigen-antibody binding events [ 3 , 4 , 20 , 21 , 25 – 27 ]. In particular, semiconducting monolayers MoS 2 and WSe 2 (with a band gap of about 1.7–1.8 eV [ 13 ]) exhibit a reduced leakage current and a high on/off current ratio in FET architectures enabling reliable and accurate biosensing [ 21 , 28 , 29 ]. In this regard, Sarkar et al. [ 21 ] have reported MoS 2 -BioFETs exhibiting the potential to detect streptavidin in concentrations as low as 100 femtomolar (fM), while Wang et al. [ 2 ] and Park et al. [ 4 ] have also demonstrated that MoS 2 -BioFETs can enable 100–400 fM-level detection limits for the prostate-specific antigen (PSA). Also for the detection of PSA, Hossain et al. [ 3 ] have reported an ultra-sensitive WSe 2 -BioFET with a detection limit of 10 fg/mL PSA, the lowest concentration detected so far by any BioFET. Although numerous experimental studies and prototypes have been developed focusing on the characterization of TMD-based immunological FETs (ImmunoFETs) for specific and label-free sensing of proteins through antigen-antibody interaction, there is a noticeable lack of theoretical analysis and models able to rationalize, explain, optimize, and predict the response of the Sensors 2023,23, 1840 3 of 16 2D BioFETs. However, in the case of electrolyte-gated graphene-based [ 30 – 32 ] and organic (EGOFETs) [ 33 – 35 ] field-effect sensors, some works have already been published regarding the modeling of their static and dynamic electrical response, where the latter have recently been also demonstrated as potential candidates for biosensing applications [ 36 – 39 ]. The performance of BioFETs depends on complex physical and chemical processes taking place at the interface of the solid–liquid materials, including electrolyte screening, site-binding charge, and biomolecule surface binding dynamics [ 40 ] that demand a comprehensive theoretical analysis enabling a deeper understanding of the operating principles of 2D BioFETs. To accurately predict the sensor response upon binding of protein analytes, it thus becomes necessary to model these physical and chemical processes [ 41 ]. To make progress in this goal, this work proposes a thorough compact model of 2D EIS field-effect biosensors by combining the electrical description of the membrane originating from the eventual formation of a protein layer in the electrolyte [ 42 ] and a physics-based model of 2D TMD-based FETs previously developed and tested by some of the authors [ 43 ]. The rest of the paper is organized as follows. In Section 2, the theoretical foundations supporting the model are presented. In Section 3, the model for 2D field-effect biosensors is exploited to examine the impact of ionic screening and surface charged groups on the sensor response. The accuracy of the compact model is validated by comparing the simulations against experimental data of an MoS 2 -based streptavidin detector and finally, Section 4draws the main conclusions. 2. Physics-Based Modeling of 2D Field-Effect Biosensors The sketch of a 2D field-effect biosensor is shown in Figure 1. The device consists of a field-effect transistor where the top-gate metal is substituted by an electrolyte solution with a reference electrode, or liquid gate ( Vlg ), submerged in it. The dielectric layer that covers the 2D channel is functionalized with specific receptors for selectively capturing the target biomolecules. When captured, the charged biomolecules produce a gating effect, which is transduced into an electrical read-out signal in the form of a drain-to-source current or channel conductance change. The inclusion of the insulator layer over the channel acts as a barrier and guarantees an unambiguous field-effect transduction mechanism through the electrostatic control of the channel, i.e., by avoiding eventual chemisorption between the electrolyte and the sensing layer. Additionally, a back-gate electrode, Vb , located at the bottom of the device provides an extra electrostatic control of the 2D channel through the buried back-gate oxide. To achieve a realistic description of the sensor, it is critical to properly model the charge interaction at the 2D channel-insulator and insulator-electrolyte interfaces so as to accurately relate the charge carrier density induced in the sensing layer with the immersed electrode potential. Due to the presence of charged biological macromolecules in the electrolyte, e.g., proteins or single-stranded DNA fragments, an ion-permeable membrane is considered to be placed inside the electrolyte close to the insulator surface (see Figure 1). This layer of biological charged macromolecules is represented as a planar ion-permeable membrane whose potential profile can be described by analytical solutions of the Poisson–Boltzmann equation [42]. In the following, this section is split aiming to firstly describe the electrostatics (Section 2.1) and then the carrier transport (Section 2.2) inside a 2D EIS BioFET. Sensors 2023,23, 1840 4 of 16 Sensors 2023, 23, x FOR PEER REVIEW 4 of 17 Figure 1. Schematic of a two-dimensional field-effect biosensor. A sketch of the position-dependent potential is also shown, highlighting the surface charge density at the 2D channel (𝜎2D), at the oxideelectrolyte interface (𝜎0), and at the membrane-diffuse regions of the electrolyte (𝜎md). The latter comprises a charge-free layer (Stern layer) and an ion-permeable membrane due to the presence of charged macromolecules with a diffusion layer located between the barrier oxide surface and the bulk electrolyte. The potential difference from the electrolyte bulk to the barrier oxide surface, 𝜓0, encompasses two contributions originating from a potential drop (𝜓0−𝜓m) across the Stern layer extending between the outer Helmholtz plane (OHP) and the barrier oxide surface, and a potential drop across the ion-permeable membrane layer formed by charged macromolecules and the diffuse layer (𝜓m). 2.1. Electrostatics of a 2D BioFET The 1D electrostatics through an EIS structure have been previously analyzed by Bousse [44] and extended by Landheer [42] by including the ion-permeable membrane in the electrolyte to describe the effect of attached macromolecules. Following these works, and by applying charge neutrality to the structure, we can get 𝜎2D+𝜎0+𝜎md=0 (1) where 𝜎2D, 𝜎0, 𝜎md are the surface charge densities associated to the 2D channel (addressed in Section 2.1.1), the oxide-electrolyte interface (Section 2.1.2), and the membranediffuse regions of the electrolyte (Section 2.1.3), respectively (see Figure 1). Each of these charges needs to be modeled before charge neutrality can be applied. 2.1.1. Modeling of the Surface Charge Density in a 2D Semiconductor (𝜎2D) The surface charge density in an n-type (p-type) 2D semiconductor can be calculated by assuming the effective mass approximation, i.e., a parabolic dispersion relationship at the lowest (highest) energies of the conduction (valence) band; and using Fermi–Dirac statistics as follows [43,45]: 𝜎2D(𝜙ch)=𝑞{𝑝(𝜙ch) if 𝑝-type −𝑛(𝜙ch) if 𝑛-type =𝜙𝑡ℎ { 𝐶dq,plog(1+𝑒𝜙ch𝜙th ⁄) if 𝑝-type −𝐶dq,nlog(1+𝑒−𝜙ch𝜙th ⁄) if 𝑛-type (2) where 𝑞 is the elementary charge; 𝑛(𝜙ch) (𝑝(𝜙ch)) is the electron (hole) density; 𝜙th= 𝑘B𝑇/𝑞 is the thermal voltage; 𝑘B is the Boltzmann constant; 𝑇 is the temperature; and 𝐶dq,n = 𝑞2𝐷0,n (𝐶dq,p = 𝑞2𝐷0,p) is defined as the electron (hole) degenerated-quantum capacitance that corresponds to the upper-limit achievable when the electron (hole) density becomes heavily degenerated [46]. The conduction (valence) band density of states reads as Figure 1. Schematic of a two-dimensional field-effect biosensor. A sketch of the position-dependent potential is also shown, highlighting the surface charge density at the 2D channel ( σ2D ), at the oxideelectrolyte interface ( σ0 ), and at the membrane-diffuse regions of the electrolyte ( σmd ). The latter comprises a charge-free layer (Stern layer) and an ion-permeable membrane due to the presence of charged macromolecules with a diffusion layer located between the barrier oxide surface and the bulk electrolyte. The potential difference from the electrolyte bulk to the barrier oxide surface, ψ0 , encompasses two contributions originating from a potential drop ( ψ0−ψm ) across the Stern layer extending between the outer Helmholtz plane (OHP) and the barrier oxide surface, and a potential drop across the ion-permeable membrane layer formed by charged macromolecules and the diffuse layer (ψm). 2.1. Electrostatics of a 2D BioFET The 1D electrostatics through an EIS structure have been previously analyzed by Bousse [ 44 ] and extended by Landheer [ 42 ] by including the ion-permeable membrane in the electrolyte to describe the effect of attached macromolecules. Following these works, and by applying charge neutrality to the structure, we can get σ2D +σ0+σmd =0 (1) where σ2D , σ0 , σmd are the surface charge densities associated to the 2D channel (addressed in Section 2.1.1), the oxide-electrolyte interface (Section 2.1.2), and the membrane-diffuse regions of the electrolyte (Section 2.1.3), respectively (see Figure 1). Each of these charges needs to be modeled before charge neutrality can be applied. 2.1.1. Modeling of the Surface Charge Density in a 2D Semiconductor (σ2D) The surface charge density in an n-type (p-type) 2D semiconductor can be calculated by assuming the effective mass approximation, i.e., a parabolic dispersion relationship at the lowest (highest) energies of the conduction (valence) band; and using Fermi–Dirac statistics as follows [43,45]: σ2D(φch)=qp(φch)if p−type −n(φch)if n−type =φth     Cdq,plog1+e φch φth if p−type −Cdq,nlog1+e −φch φth if n−type (2) where q is the elementary charge; n(φch) ( p(φch) ) is the electron (hole) density; φth =kBT/q is the thermal voltage; kB is the Boltzmann constant; T is the temperature; and Cdq,n =q2D0,n (Cdq,p =q2D0,p) is defined as the electron (hole) degenerated-quantum Sensors 2023,23, 1840 5 of 16 capacitance that corresponds to the upper-limit achievable when the electron (hole) density becomes heavily degenerated [ 46 ]. The conduction (valence) band density of states reads as    D0,p =gh,1m∗ h,1/2π¯h2+gh,2m∗ h,2/2π¯h2exp[−∆Eh,1→2/kBT]if p−type D0,n =ge,1m∗ e,1/2π¯h2+ge,2m∗ e,2/2π¯h2exp[−∆Ee,1→2/kBT]if n−type (3) where ¯h is the reduced Planck’s constant; ge,1 , ge,2 ( gh,1 , gh,2 ) are the degeneracy factors; and m∗ e,1 , m∗ e,2 ( m∗ h,1 , m∗ h,2 ) are the conduction (valence) band effective masses at the first and second lowest (highest) valleys, respectively. The second conduction (valence) valley is non-negligible in most TMDs since the energy separation between the lowest conduction (highest valence) valleys, ∆Ee,1→2 ( ∆Eh,1→2 ), is only around 2 kBT [ 47 , 48 ]. Thus, two conduction (valence) band valleys may participate in the transport process. On the contrary, the rest of the valleys in the band structure are considered far enough in terms of energy to neglect their contribution to the electrical conduction [ 49 ]. This analytical approach has proved its accuracy when modeling MoS 2 -FETs as demonstrated by Cao et al. [ 50 ] and Suryavanshi and Pop [ 51 ]. The chemical potential, φch , represents the shift of the quasi- Fermi level with respect to the conduction (valence) band edge, and it specifically reads: φch =(Ev−EF)/qif σ2D >0≡p−type (Ec−EF)/qif σ2D <0≡n−type (4) where Ec ( Ev ) is the conduction (valence) energy band edge and EF=φ/q is the quasi- Fermi level that must fulfill the following boundary conditions at the channel edges: φ=Vs at the source and φ=Vd at the drain, where Vs and Vd are the applied source and drain voltages, respectively. 2.1.2. Modeling of the Charge at the Oxide Surface: Site-Binding Theory (σ0) To model the charge at the oxide surface, the site-binding description is assumed to analyze the charge attached to the insulator surface, i.e., the oxide surface sites are considered in equilibrium with the electrolyte by means of a proton exchange [ 52 ]. Specifically, the charging/discharging of the surfaces is the result of the uptake or release of protons H+ at amphoteric hydroxyl surface groups. The surface reactions to be considered are: −MOH+ 2↔ −MOH +H+−MOH ↔ −MO−+H+(5) where −MOH , −MO− , and −MOH+ 2 are the neutral, deprotonated, and protonated species, respectively. The dissociation constants are defined as [42]: Ka=as H+ NMO− NMOH Kb=as H+ NMOH NMOH+ 2 (6) where N i (i= −MOH , −MO− , or −MOH+ 2 ) represents the corresponding hydroxyl group surface density, and as H+ is the surface proton activity related to the bulk proton activity (ab H+) by the Boltzmann distribution as follows: as H+=ab H+e−ψ0 φth (7) where ψ0 is the surface potential drop across the electrolyte-oxide. The total number of surface sites per unit area can be decomposed as: Ns=NMOH +NMO−+NMOH+ 2(8) and the charge per unit area on the surface is given by: σ0=qNMOH+ 2−NMO−(9) Sensors 2023,23, 1840 6 of 16 By combining Equations (6)–(9), the surface charge density can be expressed by means of as H+,Ns,Kaand Kbas follows: σ0=qNs  as H+2−KaKb as H+2+Kbas H++KaKb   (10) 2.1.3. Modeling of the Charge Distribution within the Electrolyte: Stern Layer, Ion-Permeable Membrane, and Diffuse Layer (σmd) For the modeling of the electrolyte charge distribution, we assume the formation of an electric double layer (EDL) at the insulator surface with an attached ion-permeable membrane located between its surface and the bulk electrolyte due to the presence of charged macromolecules, e.g., proteins or single-stranded DNA fragments dissolved in the electrolyte that originates a diffuse layer of countercharge. Consequently, within the electrolyte with permittivity εw and ion concentration n0 , two regions are envisaged: (i) a charge-free layer; and (ii) an ion-permeable membrane with a diffusion layer. The outer Helmholtz plane (OHP) is then defined as the plane of the center of the hydrated ions closest to the dielectric in contact with the solution [ 53 ]. Thus, in the simplest embodiment of the Gouy–Chapman–Stern model [ 54 ], the potential difference from the electrolyte bulk to the oxide surface, ψ0 , encompasses two contributions originating from the aforementioned regions: (i) a potential drop ( ψ0−ψm ) across a depleted region of ionic charges close to the surface [ 54 – 56 ], namely the Stern layer extending between the OHP and the insulator surface region and characterized by the so-called Stern capacitance ( CStern ); and (ii) a potential drop across the ion-permeable membrane layer consisting of the charged macromolecules and a diffuse layer (ψm) [42] (see Figure 1). Regarding the ion-permeable membrane, the solution concentration within this region is still assumed to be n0 , although the dielectric constant in the membrane ( εm ) can be different from that of the electrolyte due to the presence of macromolecules, the reduced intermolecular hydrogen bonding of the water near the macromolecular surface, and the high counterion concentrations around the molecules [ 57 ]. The membrane contains fixed charges with concentration Nm uniformly distributed and with a thickness enough to achieve charge neutrality inside it. Therefore, the Donnan potential is reached at the core of the membrane where the electric field is zero. According to Landheer et al. [ 42 ], this is a reasonable assumption because charge neutrality in the membrane depends on the screening length inside it. This screening length is shorter than the corresponding one in the electrolyte because the fixed charge in the membrane attracts ions, mostly when Nmn0 (low solution concentration). Beyond the membrane layer, the diffuse layer is originating from the presence of mobile hydrated ions in the electrolyte. This approach is also adopted by Fernandes et al. in [58], where the Donnan potential is expressed as [42]: ψDP =φthsinh−1Nm 2n0=φthlog  Nm 2n0+s1+Nm 2n02 (11) As ψDP is considered to drop across the membrane, the total net charge density in the membrane and diffuse layer in the electrolyte reads as: σmd =−sgn(ψm−ψDP)2pqn0φthεmcoshψm φth −coshψDP φth −ψm−ψDP φth sinhψDP φth 1/2 (12) Following the approach proposed by Fernandes et al. in [ 58 ], Dak et al. in [ 59 ], and validated by Martinoia and Massobrio in [ 60 ], σ2D is considered negligible compared Sensors 2023,23, 1840 7 of 16 with the rest of charge densities in Equation (1). Under this consideration, we obtain the following system of coupled equations σ0=−σmd →(ψ0=ψm+σ0(ψ0) CStern ψm=ψ0+σmd(ψm) CStern (13) From the perspective of a circuit-level model, the system in Equation (13) can be solved as a sub-circuit block that plays the role of a non-linear voltage source −ψ0 that accounts for the voltage drop across the electrolyte and depends on the pH or analyte concentration [58–60] . To solve the system of equations in Equation (13), a construct is implemented in Verilog-A to force the circuit simulator to obtain ψ0 during run-time [43,61,62] . The resulting equivalent circuit for 2D BioFETs is shown in Figure 2. Thanks to this approach, the potential drop in the electrolyte −ψ0 is decoupled from the surface charge density at the sheet channel, allowing the calculation of the charge density in the 2D channel of a double-gated EIS BioFET as follows: σ2D =−CtoxVlg −Vgo −ψ0−φ+φch−Cbox(Vb−Vbo −φ+φch)(14) where Ctox =εtox/ttox ( Cbox =εbox/tbox ) is the top- (back)-oxide capacitance per unit area, with εtox ( εbox ) the top- (back)-dielectric permittivity and ttox ( tbox ) the top- (back)-oxide thickness. The liquid- (back)-gate offset voltage Vg0 ( Vb0 ) comprises the work function difference between the electrode and the 2D channel as well as the additional fixed charge owing to impurities or doping [63]. Sensors 2023, 23, x FOR PEER REVIEW 7 of 17 𝜎0=−𝜎md→{ 𝜓0=𝜓m+𝜎0(𝜓0) 𝐶Stern 𝜓m=𝜓0+𝜎md(𝜓m) 𝐶Stern (13) From the perspective of a circuit-level model, the system in Equation (13) can be solved as a sub-circuit block that plays the role of a non-linear voltage source −𝜓0 that accounts for the voltage drop across the electrolyte and depends on the pH or analyte concentration [58–60]. To solve the system of equations in Equation (13), a construct is implemented in Verilog-A to force the circuit simulator to obtain 𝜓0 during run-time [43,61,62]. The resulting equivalent circuit for 2D BioFETs is shown in Figure 2. Thanks to this approach, the potential drop in the electrolyte −𝜓0 is decoupled from the surface charge density at the sheet channel, allowing the calculation of the charge density in the 2D channel of a double-gated EIS BioFET as follows: 𝜎2D=−𝐶tox(𝑉lg−𝑉go−𝜓0−𝜙+𝜙ch)−𝐶box(𝑉b−𝑉bo−𝜙+𝜙ch) (14) where 𝐶tox=𝜀tox/𝑡tox (𝐶box=𝜀box/𝑡box) is the top- (back)-oxide capacitance per unit area, with 𝜀tox (𝜀box) the top- (back)-dielectric permittivity and 𝑡tox (𝑡box) the top- (back)-oxide thickness. The liquid- (back)-gate offset voltage 𝑉g0 (𝑉b0) comprises the work function difference between the electrode and the 2D channel as well as the additional fixed charge owing to impurities or doping [63]. Figure 2. Equivalent circuit of the Verilog-A compact model presented in this work. The pH- and analyte-dependent potential drop in the electrolyte represented by the red box is decoupled from the surface charge density at the 2D channel and calculated by solving Equation (13). The blue box represents the large-signal model for 2D semiconductor-based field-effect transistors developed by the authors in [43]. As depicted in Figure 2, the large-signal model can be conceptually split into two parts. One, represented by the blue box, is able to predict the electrical read-out of an electrostatically gated 2D channel as far as the band structure of the semiconductor can be modeled under an effective mass approach, i.e., the dispersion relationship at the conduction/valence band minima/maxima can be approximated by a parabola [43,51]. On the other hand, the Verilog-A construct, represented by the red box in Figure 2, determines the voltage drop at the electrolyte generated by charged macromolecules due to the targets and receptors if they can be described by an ion-permeable membrane. In this regard, the model can be generalized not only to a broader class of 2D semiconductors but also to different substances/analytes [5], such as, e.g., the biotin and streptavidin pair, or avidin, which also shows affinity for biotin [64]. The model would also be able to predict the sensitivity in response to DNA hybridization, where the ensemble of surface-bound oligomers can be described as a charged ion-permeable membrane [42,65]. It is worth noting that the model assumes the a priori functionalization of the dielectric layer with specific receptors for selectively capturing the target biomolecules. From the perspective of theoretical modeling, the analysis of the specificity is not trivial and compact models have to Figure 2. Equivalent circuit of the Verilog-A compact model presented in this work. The pH- and analyte-dependent potential drop in the electrolyte represented by the red box is decoupled from the surface charge density at the 2D channel and calculated by solving Equation (13). The blue box represents the large-signal model for 2D semiconductor-based field-effect transistors developed by the authors in [43]. As depicted in Figure 2, the large-signal model can be conceptually split into two parts. One, represented by the blue box, is able to predict the electrical read-out of an electrostatically gated 2D channel as far as the band structure of the semiconductor can be modeled under an effective mass approach, i.e., the dispersion relationship at the conduction/valence band minima/maxima can be approximated by a parabola [ 43 , 51 ]. On the other hand, the Verilog-A construct, represented by the red box in Figure 2, determines the voltage drop at the electrolyte generated by charged macromolecules due to the targets and receptors if they can be described by an ion-permeable membrane. In this regard, the model can be generalized not only to a broader class of 2D semiconductors but also to different substances/analytes [ 5 ], such as, e.g., the biotin and streptavidin pair, or avidin, which also shows affinity for biotin [ 64 ]. The model would also be able to predict the sensitivity in response to DNA hybridization, where the ensemble of surface-bound oligomers can be described as a charged ion-permeable membrane [ 42 , 65 ]. It is worth noting that the model assumes the a priori functionalization of the dielectric layer with specific receptors for selectively capturing the target biomolecules. From the perspective Sensors 2023,23, 1840 8 of 16 of theoretical modeling, the analysis of the specificity is not trivial and compact models have to rely on previous biochemical research on the interactions of the receptor with other molecules, with the receptor-target complex being eventually described in terms of its charge. 2.2. Drain Current Transport through a 2D EIS BioFET In the diffusive regime, the drain current of a 2D EIS BioFET can be accurately calculated by the following closed-form expression [45]: Ids =       µpW LCdq,pφ2 th1+Cdq,p Ctb u2 d−u2 s 2+(e−us−e−ud)if p−type µnW LCdq,nφ2 th1+Cdq,n Ctb u2 s−u2 d 2+(e−ud−e−us)if n−type (15) where W and L are the channel width and length, respectively; µn ( µp ) is the electron (hole) effective mobility; Ctb =Ctox +Cbox is the sum of the geometrical top- and back-oxide capacitances per unit area; and the function u(φch)is defined as follows: u(φch)=       log1+e φch φth if p−type log1+e −φch φth if n−type (16) where us=u(φch,s) and ud=u(φch,d) are calculated from the electrostatics in Equations (2) and (14) as φch,s =φch|φ=Vsand φch,d =φch|φ=Vd. 3. Results and Discussion In this section, we provide a validation of the theoretical modeling of the EIS 2D BioFETs addressed in Section 2. To do so, we compare the outcome of the compact model against experimental measurements of a MoS 2 -FET performing as both a pH detector (Section 3.1) and a streptavidin biosensor (Section 3.2). The details of the device fabrication and characterization are reported by Sarkar et al. in [21]. The MoS2channel was obtained by micromechanical exfoliation technique and was transferred onto 270 nm SiO 2 /highly doped Si substrate. The source/drain metal contact stacks are 60 nm/100 nm Ti/Au and, importantly, are passivated with a dielectric layer to protect them from the electrolyte, thus, preventing eventual direct contact between the electrolyte and the edge contacts that would allow the direct adsorption of ions and/or biomolecules. The role of the oxide barrier is played by a 30 nm thick layer of HfO 2 [ 21 ]. An Ag/AgCl reference electrode is used to bias the electrolyte solution formed by 0.01 × Phosphate Buffered Saline (PBS). Table 1 summarizes the parameters and values characterizing the device, electrolyte, ion-permeable membrane, and electrolyte-oxide interface used in the simulation. 3.1. MoS2-FET as an Ion-Sensitive Sensor The operation of the MoS 2 -FET is first analyzed when the pH of the electrolytic solution is modified. Figure 3shows the simulated and measured transfer characteristics ( Ids −Vlg curves) of the n-type MoS 2 -based ion-sensitive FET for three different pH values (pH = 3, 4, 5) in linear (left) and logarithmic (right) scales. To perform the simulation of the device as an ion-detector, the charge concentration in the membrane is set to Nm= 0 (which implies that ψDP = 0) and the permittivity of the membrane is assumed to be the same as the electrolyte, namely εm→εw=80ε0. Sensors 2023,23, 1840 9 of 16 Table 1. Parameters of the modeled MoS2-BioFET. Parameter Value Parameter Value L(µm) 5 [21]µn(cm2/Vs) 20 W(µm) 20 [21]εw80ε0 ttox (nm) 30 [21]εm80ε0 εtox [HfO2] 25 pKa7 [66] tbox (nm) 270 [21] pKbb7 [66] εbox [SiO2] 3.9 CStern (µF/cm2)20 [67] Vgo (V) 0.48 i0(mM) 1 Vbo (V) 0 Ns(cm−2) 4 ×1014 [66] m∗ e,1/m00.54 [68]Nr(cm−2) 2.3 ×1013 m∗ e,2/m00.58 [68]Nt(fM) 100 ge,1 2Kc(M−1) 1013 [69] ge,2 6hm(nm) 5 [70] ∆Ee,1→2(eV) 0.07 [47]Vds (V) 1 The pH at the point of zero charge is defined as pHpzc =(pKa+pKb)/ 2, with pKa=−log10(Ka) , pKb=−log10(Kb) , and pH =−log10ab H+ . The salt concentration can be calculated as n0=NAi0 , where NA is the Avogadro constant and i0 is the ionic molar concentration of the solution. The parameters Ns , Nr , Nt , and i0, will be modified for the different experiments. Sensors 2023, 23, x FOR PEER REVIEW 9 of 17 𝛥𝐸e,1→2 (eV) 0.07 [47] 𝑉ds (V) 1 The pH at the point of zero charge is defined as pHpzc=(pKa+pKb)/2, with pKa=−log10(Ka), pKb=−log10(Kb), and pH=−log10(aH+ b). The salt concentration can be calculated as 𝑛0=𝑁A𝑖0, where 𝑁A is the Avogadro constant and 𝑖0 is the ionic molar concentration of the solution. The parameters 𝑁s, 𝑁r, 𝑁t, and 𝑖0, will be modified for the different experiments. 3.1. MoS2-FET as an Ion-Sensitive Sensor The operation of the MoS2-FET is first analyzed when the pH of the electrolytic solution is modified. Figure 3 shows the simulated and measured transfer characteristics (𝐼ds− 𝑉lg curves) of the n-type MoS2-based ion-sensitive FET for three different pH values (pH = 3, 4, 5) in linear (left) and logarithmic (right) scales. To perform the simulation of the device as an ion-detector, the charge concentration in the membrane is set to 𝑁m=0 (which implies that 𝜓DP=0) and the permittivity of the membrane is assumed to be the same as the electrolyte, namely 𝜀m→𝜀w=80𝜀0. Indeed, we check that 𝑁m=0 gets back to our previously reported compact model for 2D EIS ion-sensitive FETs (ISFETs) reported in [71]. The agreement between the model outcome and measurements is excellent for all regimes of operation as shown in Figure 3. The performance of this MoS2 technology for ion detection in terms of current and voltage sensitivities for the different operation regions can also be found in [71]. Figure 3. Simulation (solid lines) and measurements (symbols) of the drain current of the MoS2-FET described in Table 1 and reported in [21] for different pH = 3 (blue), 4 (red), and 5 (green). Left (right) axis corresponds to a linear (logarithmic) scale. 3.2. MoS2-FET as a Biosensor of Charged Macromolecules The specific capability of the MoS2-BioFET to detect biomolecules is tested on the well-known biotin—streptavidin interaction [72], where the biotin and streptavidin pair act as models for receptor and target molecules, respectively. First, we explore the impact on the device characteristics of the charge concentration inside the membrane formed by the macromolecules. In this regard, Figure 4a,b shows the transfer characteristics for the MoS2-BioFET described in Table 1 at different negative and positive charge concentrations in the membrane, respectively. To boost the sensitivity, the number of surface sites and the salt concentration has been set to 𝑁s=0 cm−2 and 𝑖0=1 mM, respectively. An increase in the negative (positive) membrane charge density, 𝑁m, shifts the curves towards higher (lower) 𝑉lg values, thus increasing (reducing) the threshold voltage, as shown in Figure 4a,b. Figure 3. Simulation (solid lines) and measurements (symbols) of the drain current of the MoS 2 -FET described in Table 1and reported in [ 21 ] for different pH = 3 (blue), 4 (red), and 5 (green). Left (right) axis corresponds to a linear (logarithmic) scale. Indeed, we check that Nm= 0 gets back to our previously reported compact model for 2D EIS ion-sensitive FETs (ISFETs) reported in [ 71 ]. The agreement between the model outcome and measurements is excellent for all regimes of operation as shown in Figure 3. The performance of this MoS 2 technology for ion detection in terms of current and voltage sensitivities for the different operation regions can also be found in [71]. 3.2. MoS2-FET as a Biosensor of Charged Macromolecules The specific capability of the MoS 2 -BioFET to detect biomolecules is tested on the well-known biotin—streptavidin interaction [ 72 ], where the biotin and streptavidin pair act as models for receptor and target molecules, respectively. First, we explore the impact on the device characteristics of the charge concentration inside the membrane formed by the macromolecules. In this regard, Figure 4a,b shows the transfer characteristics for the MoS 2 -BioFET described in Table 1at different negative and positive charge concentrations in the membrane, respectively. To boost the sensitivity, the number of surface sites and the salt concentration has been set to Ns= 0 cm −2 and i0= 1 mM, respectively. An increase in the negative (positive) membrane charge density, Sensors 2023,23, 1840 16 of 16 55. Ajay; Narang, R.; Saxena, M.; Gupta, M. Analytical Model of pH Sensing Characteristics of Junctionless Silicon on Insulator ISFET. IEEE Trans. Electron Devices 2017,64, 1742–1750. [CrossRef] 56. Wang, H.; Pilon, L. Accurate Simulations of Electric Double Layer Capacitance of Ultramicroelectrodes. J. Phys. Chem. C 2011 , 115, 16711–16719. [CrossRef] 57. Jin, R.; Breslauer, K.J. Characterization of the Minor Groove Environment in a Drug-DNA Complex: Bisbenzimide Bound to the Poly[d(AT)·poly[d(AT)]Duplex. Proc. Natl. Acad. Sci. USA 1988,85, 8939–8942. [CrossRef] 58. Fernandes, P.G.; Stiegler, H.J.; Zhao, M.; Cantley, K.D.; Obradovic, B.; Chapman, R.A.; Wen, H.-C.; Mahmud, G.; Vogel, E.M. SPICE Macromodel of Silicon-on-Insulator-Field-Effect-Transistor-Based Biological Sensors. Sensors Actuators B Chem. 2012 ,161, 163–170. [CrossRef] 59. Dak, P.; Seo, W.; Jung, B.; Alam, M.A. A Physics-Based (Verilog-A) Compact Model for DC, Quasi-Static Transient, Small-Signal, and Noise Analysis of MOSFET-Based pH Sensors. IEEE Trans. Electron Devices 2017,64, 1285–1293. [CrossRef] 60. Martinoia, S.; Massobrio, G. A Behavioral Macromodel of the ISFET in SPICE. Sensors Actuators B Chem. 2000 ,62, 182–189. [CrossRef] 61. Landauer, G.M.; Jiménez, D.; González, J.L. An Accurate and Verilog-A Compatible Compact Model for Graphene Field-Effect Transistors. IEEE Trans. Nanotechnol. 2014,13, 895–904. [CrossRef] 62. Pasadas, F.; Feijoo, P.C.; Mavredakis, N.; Pacheco-Sanchez, A.; Chaves, F.A.; Jiménez, D. Compact Modeling Technology for the Simulation of Integrated Circuits Based on Graphene Field-Effect Transistors. Adv. Mater. 2022,34, 2201691. [CrossRef] 63. Jiménez, D. Drift-Diffusion Model for Single Layer Transition Metal Dichalcogenide Field-Effect Transistors. Appl. Phys. Lett. 2012,101, 243501. [CrossRef] 64. Lowe, B.M.; Sun, K.; Zeimpekis, I.; Skylaris, C.-K.; Green, N.G. Field-Effect Sensors—From pH Sensing to Biosensing: Sensitivity Enhancement Using Streptavidin–Biotin as a Model System. Analyst 2017,142, 4173–4200. [CrossRef] [PubMed] 65. Cuesta-Lopez, J.; Toral-Lopez, A.; Marin, E.G.; G. Ruiz, F.; Pasadas, F.; Medina-Rull, A.; Godoy, A. Variability Assessment of the Performance of MoS2-Based BioFETs. Chemosensors 2023,11, 57. [CrossRef] 66. Tarasov, A.; Wipf, M.; Stoop, R.L.; Bedner, K.; Fu, W.; Guzenko, V.A.; Knopfmacher, O.; Calame, M.; Schönenberger, C. Understanding the Electrolyte Background for Biochemical Sensing with Ion-Sensitive Field-Effect Transistors. ACS Nano 2012 ,6, 9291–9298. [CrossRef] 67. Van Hal, R.E.G.; Eijkel, J.C.T.; Bergveld, P. A General Model to Describe the Electrostatic Potential at Electrolyte Oxide Interfaces. Adv. Colloid Interface Sci. 1996,69, 31–62. [CrossRef] 68. Wang, H.; Yu, L.; Lee, Y.-H.; Shi, Y.; Hsu, A.; Chin, M.L.; Li, L.-J.; Dubey, M.; Kong, J.; Palacios, T. Integrated Circuits Based on Bilayer MoS2Transistors. Nano Lett. 2012,12, 4674–4680. [CrossRef] 69. Kuhn, B.; Kollman, P.A. A Ligand that Is Predicted to Bind Better to Avidin than Biotin: Insights from Computational Fluorine Scanning. J. Am. Chem. Soc. 2000,122, 3909–3916. [CrossRef] 70. Piletska, E.V.; Piletsky, S.A. Size Matters: Influence of the Size of Nanoparticles on Their Interactions with Ligands Immobilized on the Solid Surface. Langmuir 2010,26, 3783–3785. [CrossRef] 71. El Grour, T.; Pasadas, F.; Medina-Rull, A.; Najari, M.; Marin, E.G.; Toral-Lopez, A.; G. Ruiz, F.; Godoy, A.; Jiménez, D.; El Mir, L. Compact Modeling of pH-Sensitive FETs Based on 2-D Semiconductors. IEEE Trans. Electron Devices 2021 ,68, 5916–5919. [CrossRef] 72. Stern, E.; Klemic, J.F.; Routenberg, D.A.; Wyrembak, P.N.; Turner-Evans, D.B.; Hamilton, A.D.; LaVan, D.A.; Fahmy, T.M.; Reed, M.A. Label-Free Immunodetection with CMOS-Compatible Semiconducting Nanowires. Nature 2007,445, 519–522. [CrossRef] 73. Nair, P.R.; Alam, M.A. Performance Limits of Nanobiosensors. Appl. Phys. Lett. 2006,88, 233120. [CrossRef] 74. Søndergaard, C.R.; Olsson, M.H.M.; Rostkowski, M.; Jensen, J.H. Improved Treatment of Ligands and Coupling Effects in Empirical Calculation and Rationalization of pKa Values. J. Chem. Theory Comput. 2011,7, 2284–2295. [CrossRef] 75. Olsson, M.H.M.; Søndergaard, C.R.; Rostkowski, M.; Jensen, J.H. PROPKA3: Consistent Treatment of Internal and Surface Residues in Empirical pKa Predictions. J. Chem. Theory Comput. 2011,7, 525–537. [CrossRef] [PubMed] 76. Lee, J.; Kim, M.J.; Yang, H.; Kim, S.; Yeom, S.; Ryu, G.; Shin, Y.; Sul, O.; Jeong, J.K.; Lee, S.-B. Extended-Gate Amorphous InGaZnO Thin Film Transistor for Biochemical Sensing. IEEE Sens. J. 2021,21, 178–184. [CrossRef] Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.