Determining major factors controlling phosphorus removal by promising adsorbents used for lake restoration: a linear mixed model approach
Abstract
This work was supported by Junta de Andalucía project P10-RNM-6630 [Proyectos de Excelencia, Spain]; MINECO CTM 2013-46951-R project; and MAT 2016-78778-R project [Spain]. Authors would also like to thank Fernando Ortega for helping in the sampling procedure.
Full text
1 Title: Determining major factors controlling phosphorus removal by promising adsorbents used for lake restoration: a linear mixed model approach Authors: A. Funesa,b*, F. J. Martíneza, I. Álvarez-Manzanedaa,b, J.M. Conde-Porcunaa,b, J. de Vicente c, F. Guerrerod,e and I. de Vicentea,b Affiliations: (a) Departamento de Ecología, Facultad de Ciencias, Universidad de Granada, 18071, Granada (Spain) (b) Instituto del Agua, Universidad de Granada, 18071, Granada (Spain) (c) Departamento de Física Aplicada, Facultad de Ciencias, Universidad de Granada, 18071, Granada (Spain) (d) Departamento de Biología Animal, Biología Vegetal y Ecología, Universidad de Jaén, 23071 Jaén (Spain) (e) Centro de Estudios Avanzados en Ciencias de la Tierra, Universidad de Jaén, 23071 Jaén (Spain) Full address for correspondence: *Corresponding author: Departamento de Ecología, Facultad de Ciencias, Universidad de Granada, 18071, Granada (Spain) Phone: (+34) 958 248323; Fax: (+34) 958 243093; email: [email protected]
2 Abstract Phosphorus (P) removal from lake/drainage waters by novel adsorbents may be affected by competitive substances naturally present in the aqueous media. Up to date, the effect of interfering substances has been studied basically on simple matrices (single-factor effects) or by applying unsuitable statistical approaches when using natural lake water. In this study, we determined major factors controlling P removal efficiency in 20 aquatic ecosystems in the southeast Spain by using linear mixed models. Two nonmagnetic -CFH-12® and Phoslock®- and two magnetic materials -hydrous lanthanum oxide loaded silica-coated magnetite (Fe-Si-La) and commercial zero-valent iron particles (FeHQ)- were tested to remove P at two adsorbent dosages. Results showed that the type of adsorbent, the adsorbent dosage and color of water (indicative of humic substances) are major factors controlling P removal efficiency. Differences in physicochemical properties (i.e. surface charge or specific surface), composition and structure explain differences in maximum P adsorption capacity and performance of the adsorbents when competitive ions are present. The highest P removal efficiency, independently on whether the adsorbent dosage was low or high, were 85-100% for Phoslock and CFH-12®, 70-100% for Fe-Si-La and 0-15% for FeHQ. The low dosage of FeHQ, compared to previous studies, explained its low P removal efficiency. Although non-magnetic materials were the most efficient, magnetic adsorbents (especially Fe-Si- La) could be proposed for P removal as they can be recovered along with P and be reused, potentially making them more profitable in a long-term period. Keywords: phosphorus, magnetic particles, Phoslock®, CFH-12®, linear mixed model, lake restoration.
3 Introduction Sewage, industrial discharge and agricultural runoff are the main sources of phosphorus (P) inputs into freshwater bodies, being the main cause of eutrophication (Burkholder, 2000; Carpenter, 2005). At global scale, the accumulation of P in terrestrial and freshwater aquatic ecosystems is 75% greater than pre-industrial levels (Bennett et al., 2001). In-lake addition of adsorbents, with the main objective of reducing lake water P concentration, is a recommendable lake management tool when the external P load has been previously reduced or the diffuse P sources are dominant (Deppe and Benndorf, 2002; Cooke et al., 2005). A wide variety of P adsorbents with different physicochemical characteristics are commercially available. Aluminum (Al), iron (Fe) and calcium (Ca) salts (Hupfer and Hilt, 2008), modified zeolites (Phoslock®, Bephos® and Aqual-P®) or Fe oxy-hydroxides (CFH-12®) are some examples of non-magnetic materials proposed for P adsorption in natural systems (Gibbs and Özkundakci, 2011; Zamparas et al., 2013; Copetti et al., 2016). An important downside of non-magnetic materials is that their effectiveness and longevity may depend on the physic-chemistry and the stability of the water column, ageing and crystallization of flocs or bioturbation, among others factors (Huser et al., 2016). Bare and coated magnetic nano/microparticles such as magnetite (Fe3O4) or zero valent Fe (ZVI) have been recently proposed for P removal from freshwater bodies (de Vicente et al., 2010a; Funes et al., 2017). The recovery of the P-loaded adsorbents by applying a magnetic separation gradient is the main novelty of using magnetic adsorbents. This implies a short contact time of the adsorbent with biota, cost savings when reusing it and the possibility of recovering P for further use as potential fertilizer, which is a challenge that deserves attention given the future scarcity of rock P reserves (Cordell et al., 2009).
4 Apart from the physic-chemical characteristics of the adsorbent (e.g. particle size, specific surface area, surface charge, surface functional groups and dosage), environmental conditions (e.g. pH, ionic strength and competitive ions) play an important role in the P removal efficiency (Li et al., 2016). Berkowitz et al. (2005) reported a high affinity of reactive silicate (Si) for Al. The potential interference of Si and humic acids in the adsorption of P by Al hydroxide (de Vicente et al., 2008) and Fe oxy-hydroxides (goethite) (Sigg and Stumm, 1981; Antelo et al., 2007) has been previously suggested. Humic substances also interfere with the P adsorption on Phoslock® (Lürling et al., 2014; Dithmer et al., 2016) and present high affinity for the adsorption on magnetite surface (Illés and Tombácz, 2004). Reitzel et al. (2013) found a negative correlation between P adsorption capacity of Phoslock® and alkalinity. Apart from Dissolved Organic Carbon (DOC) and Si, major cations (Mg2+, Na+, K+) and anions (SO42-, Cl-) are negatively related to P removal by ZVI magnetic microparticles (grade HQ; hereafter FeHQ) (de Vicente et al., 2011). Funes et al. (2017) also reported a reduction in DOC and Si concentration when applying the same magnetic particles (FeHQ) to microcosms containing lake water and surface sediment from a hypertrophic lake. The high affinity of heavy metals for bentonite, Fe3O4, Fe oxides and ZVI magnetic particles is widely documented in the literature (Veli and Alyüz, 2007; Feng et al., 2012; Hua et al., 2012; Funes et al., 2014). The majority of laboratory P adsorption studies are focused on determining P removal efficiency in different matrices (i.e. Auvray et al., 2006; de Vicente et al., 2010a). Actually, the number of studies that assess the effect of interfering substances on the removal process by carrying out, either single-ion experiments (Borggaard et al., 2005; de Vicente et al., 2008; Merino-Martos et al., 2015), or adsorption experiments with natural lake water (de Vicente et al., 2008; de Vicente et al., 2011; Reitzel et al., 2013)
5 is growing. Single-ion experiments aim at evaluating the individual effect of each substances/ions on the performance of the adsorbents to remove P. Given the simplicity of this approach (single factor), the simple linear regression has been previously applied to study the relationship between an independent variable and P removal (de Vicente et al., 2008, 2011). However, natural lake waters are complex matrices in which the P removal efficiency is finally controlled by the interactions between coexisting substances/ions, the adsorbate and the adsorbent. Up to now, the statistical approaches applied in experiments with lake water are correlation analysis (Reitzel et al., 2013), simple linear regression (de Vicente et al., 2011) and principal component analysis (de Vicente et al., 2008). Unfortunately, correlation analysis and simple linear regression do not allow to distinguish if each factor by itself is interfering on P removal or if it is a consequence of the high correlation with other factors. Instead, the linear mixed models (LMMs) approach would be more suitable in these complex systems although they have not been previously used in similar studies. Mediterranean ponds are ecosystems characterized by a high catchment area to volume ratio (Álvarez-Cobelas et al., 2005). This circumstance causes that the effect of the human activities generated in its drainage basin is of greater influence than in temperate lakes. Therefore, this “diffuse pollution” is responsible for the high concentrations of nutrients, heavy metals, DOC and other ions in these Mediterranean shallow ecosystems (Smith, 2009). These high concentrations make that, in a context of lake restoration, it is crucial to evaluate the main drivers controlling P adsorption in natural lake waters. In this work, we hypothesize that the chemical composition of lake water would affect P removal efficiency by different P adsorbents. To test this hypothesis, in this manuscript we run laboratory experiments by using four different P adsorbents -two non-magnetic (CFH-12® and Phoslock®) and two magnetic [FeHQ and hydrous lanthanum (La) oxide
6 loaded silica-coated magnetite, hereafter, Fe-Si-La]- in water samples from 20 Mediterranean aquatic ecosystems at two adsorbent dosages. All these adsorbents have been previously used to efficiently remove P in laboratory/microcosms experiments (e.g. de Vicente et al., 2010a; Reitzel et al., 2013; Lyngsie et al., 2014; Lai et al., 2016; Funes et al., 2017) and, specifically Phoslock®, at field scale (e.g. Robb et al., 2003; Meis et al., 2012). Finally, our objective was to determine the major drivers (e.g. humic substances, Si, major cations/anions) affecting P removal efficiency when using the above mentioned adsorbents by using linear mixed models. 2. MATERIALS AND METHODS 2.1 Sampling and chemical analysis of lake water In March 2017, water samples with different chemical composition (Table 1) were collected from 20 inland aquatic ecosystems in southern Spain (see supplementary information SI Fig. S1). Once in the laboratory, pH and conductivity were measured with a pH meter (pH 196, WTW, Germany) and a conductivity meter (InoLab Con Level 1, WTW, Germany), respectively. Water samples were filtered through glass microfiber filters (GF/F, 0.7 µm) and the dissolved reactive P (Murphy and Riley, 1962), total dissolved Fe (Fe2+ and Fe3+; Gibbs, 1979), Si (APHA, 1995) and color were spectrophotometrically analysed (Biochrom Libra S50). Color was determined at 440 nm in 1-cm cuvettes. Water color was expressed as absorption coefficient in units of inverse meters (m−1) according to the following equation (Reche and Pace, 2002): where is the measured absorbance at 440 nm and is the optical path length (in m). Lake water used for measuring major cations [sodium (Na+), potassium (K+),
7 magnesium (Mg2+) and calcium (Ca2+)], major anions [nitrates (NO3-), sulphates (SO42-) and chlorides (Cl-)] and heavy metals [manganese (Mn2+), arsenic (As2-), copper (Cu2+) and nickel (Ni2+)] was filtered through Millipore 0.22 µm filters. Major cations and anions were measured by Ion Cromatography (IC; 940 Professional IC Vario, Metrohm) and heavy metals were analysed by inductively coupled plasma-mass spectroscopy (ICP-MS; Perkin Elmer NexION 300D). All physic-chemical parameters above mentioned were measured in the water samples four times along the experiment (six weeks): once at the beginning, twice during the experiment and the last one at the end of the experiment. Salinity of the systems was estimated by using conductivity measurements and the equation proposed by Alcorlo et al. (1996) for lakes located in the Guadalquivir Depression in southern Spain [salinity (g L-1) = 0.8211 conductivity (mS cm-1) = 0.18389]. Finally, DOC concentration was estimated from the relationship between DOC (measured with a Shimadzu TOC analyzer) and color (expressed as absorption coefficient, a440; r2 = 0.61; de Vicente et al., 2010b). 2.2 Synthesis of hydrous lanthanum oxide loaded silica-coated magnetite (Fe-Si- La) Fe-Si-La particles were synthesized following the procedure of Lai et al. (2016) with slight modifications. Briefly, 10 g of commercial bare Fe3O4 (Sigma Aldrich; 50-100 nm) was dispersed in a mixture of ethanol (1.6 mL) and distilled water (400 mL). The suspension was horizontally shaked for 10 min at 200 rpm. Afterwards, 100 mL of ammonia (28%) and 3.26 mL of tetraethyloxysilane (TEOS, 98.6%) were added to the suspension and left for shaking for 6 h at 200 rpm. The Si coated Fe3O4 was magnetically separated and the supernatant was removed. Then, 500 mL of LaCl3 (0.02 M) was added to the Si coated Fe3O4 and the pH of the suspension was raised to 10 by
8 adding 3M NaOH. After magnetic separation for 5 min, the Fe-Si-La particles were washed twice with distilled water, twice with absolute ethanol and the last time with acetone. In each washing step, the particles were sonicated for 15 min. Then, particles were air dried and stored at 4 ºC until used. 2.3 Characterization of the adsorbents CFH-12® (Kemira, Finland) is a dry, granular and amorphous ferric oxy-hydroxide with a Fe content of ~ 44% w/w. As specified by the manufacturer (CSIRO, Australia), Phoslock® is a dry and granular compound consisting of La-modified clay (~ 5 % ww La). To obtain a homogenized fine powder (~250 nm), CFH-12® and Phoslock® were crushed in a mortar. Fe-Si-La and commercial bare Fe3O4 particles were characterized with the following techniques. Surface morphology and particle size were determined by focus ion beam field-emission scanning electron microscopy (FIB-FESEM, AURIGA, Carl Zeiss SMT Inc.). A SQUID magnetometer (Quantum Design MPMS XL) was used to determine the magnetization curves of the powders at 293 K. Quantitative chemical composition of the surface was determined by X-ray photoelectron spectroscopy (XPS; Kratos Axis Ultra-DLD) with monochromatic Al Kα radiation. The wide spectrum (pass energy 160 eV) and spectra of the detected elements (pass energy 20 eV) were obtained using an electrostatic lens. The La content in Fe-Si-La was analysed by inductively coupled plasma-mass spectroscopy (ICP-MS; Perkin Elmer NexION 300D) following sample digestion with HNO3 + HF. FeHQ magnetic particles were supplied by BASF (Germany). According to the manufacturer, the composition of this powder is 97.5% iron, 0.9% carbon, 0.5%
9 oxygen, and 0.9% nitrogen. These particles are spherical in shape with an average diameter of 800 nm [see de Vicente et al. (2010a) for further characterization details]. 2.4 Adsorption isotherms The adsorption isotherms of the four adsorbents were conducted at room temperature (25 ºC) using the batch technique. The stock magnetic suspensions (50 g L-1) were prepared by adding 2.5 grams of Fe-Si-La or FeHQ in a final volume of 50 mL. Prior to their use, stock magnetic suspensions were sonicated for 5 min. A volume of 1 mL of the stock magnetic suspensions was mixed with 40 mL of 3 mM NaHCO3 in a polyethylene container and agitated for 24 h at 150 rpm. In the case of non-magnetic adsorbents (CFH-12® and Phoslock®), 0.05 g were added as dry material to polyethylene containers along with 40 mL of 3mM NaHCO3 and agitated under the same conditions. 1 mL of different P stock solutions ranging from 5 to 60 mM P was added to the containers and the pH was adjusted to 7. Suspensions were agitated again for 24 h at 150 rpm. After 24 h of agitation, pH was readjusted to 7 and suspensions were made up to 50 mL to give final P concentrations ranging from 0.1 mM to 1.2 mM. The final adsorbent concentration in the adsorption experiments was 1 g L-1 for all the adsorbents. Adsorbents were then separated from the supernatant by centrifugation (10 min, 3000 rpm) or using a variable gap magnet (5 min; PASCO scientific; EM-8641). Supernatant was filtered through glass microfiber filters (GF/F, 0.7 µm) and dissolved reactive P was spectrophotometrically determined (Murphy and Riley, 1962). The equilibrium adsorption capacity was calculated as follows: [1] being the P concentration in the control treatment, that is, the P concentration in lake water 24 h after the addition of P and without adsorbent; the equilibrium P
16 3.3.1 Effect of the type of adsorbent As seen in Table 4, the type of adsorbent had a significant effect on P adsorption. P removal efficiencies at low and high adsorbent dosage are represented for all the adsorbents in Fig. 4. Data represent the average for all aquatic ecosystems. As expected, those adsorbents with the highest maximum P adsorption capacities, CFH-12® and Phoslock® (SI Table S1), showed the highest P removal efficiencies (> 85%). Fe-Si-La was also very efficient with P removal efficiencies greater than 70% whereas FeHQ showed the lowest (≤ 15%). Tukey's post hoc test (data not shown) showed that Phoslock® removed significantly more P than CFH-12®, Fe-Si-La and FeHQ (p = 0.037, p = 0.01, p < 0.001, respectively). P removal was significantly lower for FeHQ compared to the rest of the adsorbents (p < 0.001). This result is especially striking in view of the high maximum P adsorption capacity of FeHQ (de Vicente et al., 2010a); however different explanations can be suggested. First, the low adsorption capacity of FeHQ (0.5 mg g-1; de Vicente et al., 2010a) at low P concentrations (< 0.1 mM P) compared to the rest of the adsorbents (1.6-2.5 mg g-1; see Fig. 1). Second, the adsorbent:P ratios used in this work (0.2 and 0.5 g mg-1) are seven and three fold lower, respectively, than the optimum adsorbent dosage (1.5 g mg-1) calculated by Merino- Martos et al. (2011) to efficiently remove P from solution. Even more, de Vicente et al. (2011) applied much higher adsorbent dosages (6.45 and 25.81 g mg-1) when using the same particles to remove P from different natural aquatic ecosystems. Given the low P removal by FeHQ, a complementary model was run in which FeHQ was removed, determining that the type of adsorbent was not significant (p = 0.793) for the overall model (data not shown). In this case, differences between the three other adsorbents are not relevant as determined by Tukey's test (p = 0.622, p = 0.514, p = 0.877).
17 3.3.2 Effect of the adsorbent dosage The adsorbent dosage is, as expected, a significant factor explaining the mass of adsorbed P (Table 4). As seen in Fig. 4, the high adsorbent dosage led to higher P removal efficiencies. Likewise, there is an interactive effect of the factors type of adsorbent x adsorbent dosage on adsorbed P (Table 4). As a result, a post hoc analysis of this interaction was carried out. Table 5 shows the results of simple main effects interaction analysis for type of adsorbent x adsorbent dosage. In consequence, the effect of adsorbent dosage at the different types of adsorbents was tested, and it was found that the adsorbent dosage has a significant effect on adsorbed P (p < 0.001) when using CFH-12® and Fe-Si-La but not when using Phoslock® and FeHQ (p > 0.05). Specifically, when comparing adsorbent dosages for CFH-12® (Fig. 4), we observed that the high adsorbent dosage removed significantly more P (> 99% on average for all the systems) than the low adsorbent dosage (86.1%). Similarly, when adding Fe-Si-La P removal efficiencies were significantly higher for the high dosage (> 99%) than for the low dosage (71.2%; Fig. 4). However, no differences in adsorbed P were found between the high and low adsorbent dosage for the case of Phoslock® (97.5-99.1%) and FeHQ (12.0-15.5%). Differences in the effect of adsorbent dosage on adsorbed P among the studied adsorbents explain the significant interaction between the factors type of adsorbent x adsorbent dosage obtained in the model. 3.3.3 Effect of the matrix Among all the variables included in the model, and color in lake water were the only ones related to water chemical composition that significantly affect adsorbed P (Table 4). On the one hand, the coefficient for is positive, pointing out a positive relationship between and the mass of adsorbed P. In particular, Phoslock® showed
18 the strongest Pearson correlation coefficient (r = 0.940) between and P adsorbed followed by CFH-12® (r = 0.731) and Fe-Si-La (r = 0.428). Therefore, high would enhance the mass of adsorbed P. This trend has been also observed for anionic dyes (Banerjee and Chattopadhyaya, 2017). By contrast, a negative and weak correlation (r = -0.060) between both variables were found for FeHQ as a result of the insufficient adsorbent dosage. On the other hand, the coefficient for color was negative, reflecting that the mass of adsorbed P responded inversely to increasing values of this parameter. Color in water has been reported to be a good indicator of the humic substances (humic and fulvic acids) concentration (Cuthbert and del Giorgio, 1992). In more details, Fig. 5 shows the relationship between adsorbed P and color for all the adsorbents. As indicated by r values, high values of color and thus, high lake water concentrations of humic substances, would noticeably affect the mass of adsorbed P by Fe-Si-La (r = -0.164) and by CFH-12® (r = -0.109). Previous works have reported potential interferences of humic acids on the adsorption of P onto Fe oxy-hydroxides, a similar Fe based compound to CFH-12® (Antelo et al., 2007) and onto Fe-Si-La (Lai et al., 2016). Humic substances may interact with colloids in different ways. H-bonding, ligand exchange and electrostatic interactions are the main sorption mechanisms of humic substances onto iron oxides (goethite and hematite) (Philippe and Schaumann, 2014). Frequently, several mechanisms act at the same time. The humic substances that mostly affect P adsorption onto iron oxides are fulvic acids due to a stronger electrostatic interactions with P (Weng et al., 2008). Unlike what happened to CFH-12® and Fe-Si-La, humic substances had negligible effect on adsorbed P by Phoslock® (r = -0.042) despite the fact that the DOC concentration in the studied aquatic systems were high enough to cause interferences (Lurling et al., 2014; Dithmer et al., 2016). Specifically, half of the lakes presented a
19 DOC concentrations between 1 to 10 mg L-1 and half presented values ranging from 10 to 30 mg L-1 except for Charca Suárez which showed much higher value (118 mg DOC L-1). Contrarily to our results, the competition of humic substances and P for the adsorption sites on Phoslock® has been previously reported (Dithmer et al., 2016). Similarly, Lurling et al. (2014) reported a reduced P binding by Phoslock (actually by La which is the active ingredient) when DOC concentrations were as low as 2 mg L-1 and the effect became stronger when increasing up to 14 mg DOC L-1. The stronger effect of humic substances on P adsorption by CFH-12® and Fe-La-Si than by Phoslock® may be explained by several reasons. Firstly, the high adsorption capacity of Phoslock® compared to the others adsorbents (see SI Table S1). According to the results, P removal by Phoslock® was not affected by coexisting ions and substances (almost 100% of P removal whatever the adsorbent dosage and lake water) because there are still free adsorption sites for P. However, in Fe-Si-La and CFH-12®, the adsorption sites (OH functional groups) could be blocked by the presence of humic substances and not available for P adsorption, thus reducing P removal efficiency (Lai et al., 2016; Borggaard et al., 2005). A second explanation would be the lower affinity of humic substances for clays compared to iron oxides due to the unfavourable electrostatic pattern (Philippe and Schaumann, 2014). Another reason maybe that the adsorption of humic substances on CFH-12® and on Fe-Si-La could reduce their point of zero charge (pzc) and increase electrostatic repulsion for the adsorption of anionic phosphate (Antelo et al., 2007). As seen in Table 4, there are not significant main effects of NO3- on the adsorbed P. However, there is a significant effect of the interaction type of adsorbent x NO3-. This means that the effect of NO3- on the adsorbed P depends on the type of adsorbent. Table 6 shows the post hoc analysis of this interaction in which the adjusted values of the
20 slope with respect to the adsorbed P for the level and contrasts of the type of adsorbent are indicated. According to it, the proportional relation between NO3- and adsorbed P is significantly greater (and direct, see Fig. 6) for FeHQ compared to the rest of adsorbents (p < 0.001). Likewise, this proportional relation is significantly different (and negative, see Fig. 6) for Phoslock® compared to CFH-12® and Fe-Si-La (p < 0.05 and p < 0.01, respectively). In fact, Table 7 points out that the relation between adsorbed P and NO3- is only significant for FeHQ and Phoslock®. This result may have implications in lake restoration. The efficiency of Phoslock in removing P could be reduced in lakes with high NO3- concentration whereas the efficiency of FeHQ would increase. Pr in each aquatic ecosystem is shown in Fig. 7 and Fig. 8 for non-magnetic and magnetic adsorbents, respectively. For CFH-12®, Pr was similar between lakes at low adsorbent dosage. At high adsorbent dosage of CFH-12®, Charca Suárez showed the lowest Pr (94.2%) compared to the highest value found in Grande, Padul and Cubillas (99%). For Phoslock® and Fe-Si-La, Pr was similar across lakes at high adsorbent dosage but the values were different at low adsorbent dosage. Pr by Phoslock® was slightly lower in Charca Suárez (81.3%) compared to Balax (99.9%). Pr by Fe-Si-La was notably lower in Charca Suárez (38.3%) and Canales (63.0%) compared to Colomera (82.6%), Cubillas (89.5%) and Guadalén (80.0%). For the case of FeHQ, Pr was similar between lakes at low adsorbent dosage whereas it was different at high adsorbent dosage, being Pr much lower in Puerto de los Alazores (5.3%) compared to Balax (49.0%). The lower Pr reported in Charca Suárez for all the adsorbents could be attributed to its extremely high color value (10.31 m-1), which ultimately reflects high humic substances concentration (Cuthbert and del Giorgio, 1992). Similarly, and although As was not selected in the model as explanatory variable for P adsorption, the high concentration of this metal in Charca Suárez (11.7 µg L-1) may have reduced adsorbed P by CFH-12®
21 due to competition. In fact, P and As have been reported to have a similar structure, chemical reactivity and adsorption kinetic onto iron oxides (Luengo et al., 2007; Lukkari et al., 2007). 4. Conclusions For the practical application of novel P adsorbents used for lake restoration, it is essential to assess the effects that natural substances/ions have on P removal efficiency. In this study, adsorption experimental data from 20 aquatic ecosystems, have been used for obtaining a linear mixed model. This novel methodological approach has determined that the major drivers controlling P removal are: type of adsorbent, the adsorbent dosage and the concentration of humic substances. The studied adsorbents showed the following P removal efficiency order: Phoslock® (~100%) > CFH-12® (85-100%) > Fe- Si-La (70-100%) > FeHQ (0-15%) for both adsorbent:P ratios 0.2 and 0.5 g mg-1. Phoslock® was the most efficient P adsorbent independently of adsorbent dosage and water chemical composition. Contrarily to previous studies, FeHQ showed a low P uptake due to a notable underdosing. P removal efficiency of CFH-12® and Fe-Si-La was negatively affected by high color values (high humic substances). With regards to the P removal efficiency, the non-magnetic adsorbents employed in this work were more efficient than their magnetic counterparts. However, it is important to remark that the former cannot be reused. All in all, differences in chemical properties -adsorption capacity or surface charge- and the affinity to the adsorbate and to other substances/ions play an important role in the performance of each adsorbent to remove P. 5. Acknowledgments
22 This work was supported by Junta de Andalucía project P10-RNM-6630 [Proyectos de Excelencia, Spain]; MINECO CTM 2013-46951-R project; and MAT 2016-78778-R project [Spain]. Authors would also like to thank Fernando Ortega for helping in the sampling procedure. 6. References Alcorlo, P., Baltanás, A., Montes, C., 1996. Is it possible to predict the salinity of Iberian salt lakes from their conductivity ? Hydrobiologia 330, 137–142. Álvarez-Cobelas, M., Rojo, C., Angeler, D.G., 2005. Mediterranean limnology: current status, gaps and the future. Journal of Limnology 64, 13-29. doi.org/10.4081/jlimnol.2005.13 Antelo, J., Arce, F., Avena, M., Fiol, S., López, R., Macías, F., 2007. Adsorption of a soil humic acid at the surface of goethite and its competitive interaction with phosphate. Geoderma 138, 12–19. doi:10.1016/j.geoderma.2006.10.011 APHA, 1995. Standard Methods for Examination of Water and Wastewater. 19th ed. APHA-AWWA-WPCF, Washington, DC, USA. Auvray, F., van Hullebusch, E.D., Deluchat, V., Baudu, M., 2006. Laboratory investigation of the phosphorus removal (SRP and TP) from eutrophic lake water treated with aluminium. Water Res. 40, 2713–2719. doi:10.1016/j.watres.2006.04.042 Banerjee, S., Chattopadhyaya, M.C., 2017. Adsorption characteristics for the removal of a toxic dye , tartrazine from aqueous solutions by a low cost agricultural byproduct. Arab. J. Chem. 10, S1629–S1638. doi:10.1016/j.arabjc.2013.06.005 Bartoń, K., 2012. MuMIn: Multi-model inference. R package version 1.7.2. http://CRAN.R-project.org/package=MuMIn Bates, D., Mächler, M., Bolker, B., Walker, S., 2015. Fitting linear mixed-effects
23 models using lme4. J. Stat. Soft. 67, 1–48. doi:10.18637/jss.v067.i01 Bennett, E.M., Carpenter, S.R., Caraco, N.F., 2001. Human Impact on Erodable Phosphorus and Eutrophication : A Global Perspective. BioScience 51, 227–234. Berkowitz, J., Anderson, M. A., Graham, R.C., 2005. Laboratory investigation of aluminum solubility and solid-phase properties following alum treatment of lake waters. Water Res. 39, 3918–3928. doi:10.1016/j.watres.2005.06.025 Bolker, B. M., Brooks, M. E., Clark, C. J., Geange, S. W., Poulsen, J. R., Stevens, M. H. H., White, J. S. S., 2009. Generalized linear mixed models: a practical guide for ecology and evolution. Trends Ecol. Evol. 24, 127-135. Borggaard, O.K., Raben-Lange, B., Gimsing, A.L., Strobel, B.W., 2005. Influence of humic substances on phosphate adsorption by aluminium and iron oxides. Geoderma 127, 270–279. doi:10.1016/j.geoderma.2004.12.011 Brezovska, S., Marina, B., Panova, B., Burevski, D., Bosevska, V., Stojanovska, L., 2004. The adsorption characteristics and porous structure of bentonite adsorbents as determined from the adsorption isotherms of benzene vapor. J.Serb.Chem.Soic. 69, 145–151. Burkholder, J. M. 2000. Eutrophication and oligotrophication, p. 649–670. In S. Levin (ed.), Encyclop. Biodivers. Volume 2. Academic Press, New York. Burnham, K. P., Anderson, D. R., 1998. Model selection and inference. A Practical information-theoretic approach. 2nd edition. New York: Springer. Carpenter, S.R., 2005. Eutrophication of aquatic ecosystems: bistability and soil phosphorus. Proc. Natl. Acad. Sci. U. S. A. 102, 10002–10005. doi:10.1073/pnas.0503959102 Chen, X., 2015. Modeling of experimental adsorption isotherm data. Information 6, 14– 22. doi:10.3390/info6010014
24 Cooke, G.D., Welch, E.B., Peterson, S.A., Nichols, S.A., 2005. Restoration and Management of Lakes and Reservoirs, third ed. CRC Press, Boca Raton, FL, p. 548. Copetti, D., Finsterle, K., Marziali, L., Stefani, F., Tartari, G., Douglas, G., Reitzel, K., Spears, B.M., Winfield, I.J., Crosa, G., D’Haese, P., Yasseri, S., Lürling, M., 2016. Eutrophication management in surface waters using lanthanum modified bentonite: a review. Water Res. 97, 162-174. doi:10.1016/j.watres.2015.11.056 Cordell, D., Drangert, J.O., White, S., 2009. The story of phosphorus: Global food security and food for thought. Glob. Environ. Chang. 19, 292–305. doi:10.1016/j.gloenvcha.2008.10.009 Cuthbert, I. D., del Giorgio, P., 1992. Towards a standard method of measuring color in freshwater. Limnol. Oceanogr. 37, 1319–1326. de Rosario-Martínez, HDR (2015). Analysing interactions of fitted models. https://cran.r-project.org/web/packages/phia/vignettes/phia.pdf de Vicente, I., Jensen, H.S., Andersen, F.Ø., 2008. Factors affecting phosphate adsorption to aluminum in lake water: Implications for lake restoration. Sci. Total Environ. 389, 29–36. doi:10.1016/j.scitotenv.2007.08.040 de Vicente, I., Merino-Martos, A., Cruz-Pizarro, L., de Vicente, J., 2010a. On the use of magnetic nano and microparticles for lake restoration. J. Hazard. Mater. 181, 375– 381. doi:10.1016/j.jhazmat.2010.05.020 de Vicente, I., Ortega-Retuerta, E., Mazuecos, I., Pace, M., Cole, J., Reche, I., 2010b. Variation in transparent exopolymer particles in relation to biological and chemical factors in two contrasting lake districts. Aquat. Sci. 72, 443–453 443– 453. doi:10.1007/s00027-010-0147-6 de Vicente, I., Merino-Martos, A., Guerrero, F., Amores, V., de Vicente, J., 2011.
25 Chemical interferences when using high gradient magnetic separation for phosphate removal: Consequences for lake restoration. J. Hazard. Mater. 192, 995–1001. doi:10.1016/j.jhazmat.2011.05.090 Deppe, T., Benndorf, J., 2002. Phosphorus reduction in a shallow hypereutrophic reservoir by in-lake dosage of ferrous iron. Water Res. 36, 4525–4534. doi:10.1016/S0043-1354(02)00193-8 Dithmer, L., Nielsen, U.G., Lundberg, D., Reitzel, K., 2016. Influence of dissolved organic carbon on the efficiency of P sequestration by a lanthanum modified clay 97, 39–46. doi:10.1016/j.watres.2015.07.003 Feng, L., Cao, M., Ma, X., Zhu, Y., Hu, C., 2012. Superparamagnetic high-surface-area Fe3O4 nanoparticles as adsorbents for arsenic removal. J. Hazard. Mater. 217, 439–446.Funes, A., Arco, A., Álvarez-Manzaneda, I., de Vicente, J., de Vicente, I., 2017. A microcosm experiment to determine the consequences of magnetic microparticles application on water quality and sediment phosphorus pools. Sci. Total Environ. 579, 245–253. doi:10.1016/j.scitotenv.2016.11.120 Fuchs, E., Funes, A., Saar, K., Reitzel, K., Jensen, H.S., 2018. Evaluation of dried amorphous ferric hydroxide CFH-12® as agent for binding bioavailable phosphorus in lake sediments. Sci. Total Environ. 628–629, 990–996. doi:10.1016/j.scitotenv.2018.02.059 Funes, A., de Vicente, J., Cruz-Pizarro, L., de Vicente, I., 2014. The influence of pH on manganese removal by magnetic microparticles in solution. Water Res. 53, 110– 122. doi:10.1016/j.watres.2014.01.029 Gibbs, M.M., 1979. A simple method for the rapid determination of iron in natural waters. Water Res. 13, 295–297. doi:10.1016/0043-1354(79)90209-4 Gibbs, M., Özkundakci, D., 2011. Effects of a modified zeolite on P and N processes
32 Fig. 1 0 5 10 15 20 25 30 35 40 0 3 6 9 12 15 CFH-12 Phoslock Fe-Si-La Fe3O4 q (mg P g-1) Ce (mg P L-1)
33 Fig.2
34 Fig.3 -4000 -2000 0 2000 4000 -100 -80 -60 -40 -20 0 20 40 60 80 100 Fe3O4 Fe-Si-La M (emu g-1) H (kA m-1)
35 Fig. 4 Low High 0 20 40 60 80 100 CFH-12 Phoslock Fe-Si-La FeHQ Pr (%)
36 Fig. 5 0 2 4 6 8 10 12 0,00 0,05 0,10 0,15 0,20 0,25 0,30 CFH-12 Phoslock Fe-La-Si FeHQ Color (m-1) adsorbed P (mol) r = -0,164 r = -0,109 r = -0,042 r = 0,057
37 Fig. 6 0 2 4 6 8 10 12 14 16 18 0,0 0,1 0,2 0,3 0,4 0,5 0,6 NO3 - (mg L-1) adsorbed P (µmol) Phoslock CFH-12 Fe-Si-La FeHQ
38 Fig. 7 0 20 40 60 80 100 b) Phoslock a) CFH-12 Pr (%) 0,5 g adsorbent mg-1 P 0,2 g adsorbent mg-1 P Charco del Negro Grande Chica Puerto Alazores Puerto Zafarraya Alhama Bermejales Padul Colomera Cubillas Charca Suárez Yeguas Rumblar Guadalén Castillo Orcera La Franciscuela Canales Francisco Abellán Balax 0 20 40 60 80 100
39 Fig. 8 0 20 40 60 80 100 a) Fe-Si-La b) FeHQ 0,5 g adsorbent mg-1 P 0,2 g adsorbent mg-1 P Charco del Negro Grande Chica Puerto Alazores Puerto Zafarraya Alhama Bermejales Padul Colomera Cubillas Charca Suárez Yeguas Rumblar Guadalén Castillo Orcera La Franciscuela Canales Francisco Abellán Balax 0 20 40 60 80 100 Pr (%)
40 Tables Table 1. Chemical characterization of the studied lakes (average values of four analysis). The aquatic systems were classified according to Hammer et al. (1986) as freshwater (F), subsaline (S) or hyposaline (H) systems. Table 2. Surface chemical composition (%) of bare Fe3O4 and Fe-Si-La particles by XPS. Table 3. Best models predicting P adsorption obtained through model selection (∆AICc < 2). AICc values, AICc differences (∆) and Akaike weights (ω) of the subset of models generated. l is the maximized log likelihood. (1) type of adsorbent, (2) adsorbent dose, (5) color, (7) NO3- and (11) Ccont. Table 4. Model coefficients. Estimate (the model-based estimate for the coefficient for each parameter without weighting), standard error (SE), associated Wald's z score (z) and significance level (p) for the fixed factors explaining P adsorption. Table 5. Post hoc analysis of the simple main effects for the interaction type adsorbent x adsorbent dosage. The Holm's method correction of p was used to protect the familywise error rate. Table 6. Post hoc analysis of the pairwise comparisons between the types of adsorbent for the interaction type adsorbent x NO3-. The Holm's method correction of p was used to protect the family-wise error rate. Table 7. Relationships of each type of adsorbent with NO3- concentration for the interaction type adsorbent x NO3-.
41 Table 1 Lake pH Conductivity PO43- Na+ K+ Mg2+ Ca2+ NO3- Cl- SO42- Si Color Mn As Ni Cu µS cm-1 µg L-1 mg L-1 mg L-1 mg L-1 mg L-1 mg L-1 mg L-1 mg L-1 mg L-1 m-1 µg L-1 µg L-1 µg L-1 µg L-1 1 Charco del Negro (F) 7.46 321 16.81 0.40 2.20 0.99 44.50 3.86 4.23 42.43 3.85 2.99 1.00 1.39 3.25 2.43 2 Grande (H) 6.97 3928 6.49 104.60 5.61 147.68 733.86 3.84 184.38 2268.67 9.32 2.82 74.87 3.23 29.40 6.96 3 Chica (H) 7.91 7415 0.00 543.03 12.22 352.44 727.31 7.36 991.16 2937.76 0.55 2.59 666.06 9.16 31.99 33.98 4 Puerto Alazores (F) 8.14 310 0.13 0.00 0.00 4.71 38.71 2.44 6.85 19.54 2.28 1.61 0.79 1.32 2.86 1.77 5 Puerto Zafarraya (F) 8.10 332 3.95 5.80 0.86 3.79 39.70 1.82 12.43 11.71 0.00 1.23 0.99 0.98 3.08 1.21 6 Alhama (F) 8.26 359 0.00 0.00 0.00 12.71 42.94 8.49 5.31 14.66 2.53 0.46 0.79 1.18 2.08 0.35 7 Bermejales (S) 8.26 549 0.00 0.00 0.61 29.65 57.43 5.74 7.06 135.75 1.08 0.38 0.71 1.57 3.63 0.65 8 Padul (S) 8.30 574 4.08 0.93 0.91 33.38 58.00 6.65 10.22 38.85 0.73 3.07 1.10 3.06 4.37 0.95 9 Colomera (S) 8.05 656 0.00 15.69 1.75 17.92 66.84 8.76 35.02 157.54 1.46 0.58 0.78 1.48 4.68 1.81 10 Cubillas (S) 8.11 686 0.00 7.48 1.19 25.48 78.34 8.21 20.74 161.07 1.70 0.92 0.52 1.61 5.79 1.07 11 Charca Suárez (S) 8.01 1474 141.54 95.86 19.10 57.07 81.89 0.00 192.32 130.41 10.10 10.31 3.22 11.07 6.18 6.57 12 Yeguas (F) 7.57 110 0.13 0.09 0.00 0.29 3.96 5.92 7.16 11.73 2.44 1.21 0.90 3.65 0.91 1.29 13 Rumblar (F) 7.30 235 0.00 0.24 0.25 6.41 15.45 5.25 8.04 59.64 0.00 0.77 0.85 2.66 2.39 1.77 14 Guadalén (F) 7.84 353 1.40 8.69 2.85 11.44 28.67 6.33 17.12 45.34 0.00 0.77 0.69 1.82 4.20 1.69 15 Castillo (S) 7.24 798 1.53 3.47 14.20 25.48 95.12 1.22 16.01 336.97 0.02 2.25 2.79 3.29 7.92 13.85 16 Orcera (S) 8.08 678 0.00 0.00 6.74 31.93 75.78 5.06 15.00 164.16 0.34 3.28 1.68 3.27 5.97 1.43 17 La Franciscuela (F) 8.13 336 0.00 0.00 0.00 9.40 41.87 3.35 4.27 12.39 0.38 1.00 0.57 0.41 2.62 0.14 18 Canales (F) 7.77 179 9.04 0.00 0.00 1.99 16.97 5.11 4.43 25.32 0.21 0.38 1.47 1.20 1.28 0.15 19 Francisco Abellán (S) 8.20 565 0.00 1.86 0.62 29.06 54.84 5.59 12.33 114.42 0.15 0.46 0.46 1.26 3.25 0.38 20 Balax (F) 5.82 101 5.22 0.00 0.10 0.33 5.41 16.72 5.16 22.35 3.03 0.29 52.52 0.77 6.92 0.46