Damage prediction via nonlinear ultrasound: A micro-mechanical approach
Abstract
Supplementary data associated with this article can be found, in the online version, at https://doi.org/10.1016/j.ultras.2018.10.009. All results obtained within the paper can be reproduced using formulae provided.
Full text
Contents lists available at ScienceDirect Ultrasonics journal homepage: www.elsevier.com/locate/ultras Damage prediction via nonlinear ultrasound: A micro-mechanical approach J. Melchor a,b,c,⁎ , W.J. Parnell d , N. Bochud e , L. Peralta f , G. Rus a,b,c a Department of Structural Mechanics, University of Granada, Granada, Spain b IBS Biosanitary Research Institute, Granada, Spain c MNat Scientific Unit of Excellence, University of Granada, Spain d School of Mathematics, University of Manchester, Oxford Road, Manchester M13 9PL, UK e Institut Langevin, ESPCI Paris, CNRS (UMR 7587), PSL Research University, 75005 Paris, France f Biomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK ARTICLE INFO Keywords: Non-destructive evaluation Nonlinear elasticity Ultrasound Homogenization Micro-cracks Nonlinear acoustics ABSTRACT Nonlinear constitutive mechanical parameters, predominantly governed by micro-damage, interact with ultrasound to generate harmonics that are not present in the excitation. In principle, this phenomenon therefore permits early stage damage identification if these higher harmonics can be measured. To understand the underlying mechanism of harmonic generation, a nonlinear micro-mechanical approach is proposed here, that relates a distribution of clapping micro-cracks to the measurable macroscopic acoustic nonlinearity by representing the crack as an effective inclusion with Landau type nonlinearity at small strain. The clapping mechanism inside each micro-crack is represented by a Taylor expansion of the stress-strain constitutive law, whereby nonlinear terms arise. The micro-cracks are considered distributed in a macroscopic medium and the effective nonlinearity parameter associated with compression is determined via a nonlinear Mori-Tanaka homogenization theory. Relationships are thus obtained between the measurable acoustic nonlinearity and the Landau-type nonlinearity. The framework developed therefore yields links with nonlinear ultrasound, where the dependency of measurable acoustic nonlinearity is, under certain hypotheses, formally related to the density of micro-cracks and the bulk material properties. 1. Introduction Conventional ultrasonic non-destructive evaluation (NDE) methods are sensitive to gross defects, but are generally much less sensitive to distributed micro-cracks [1–4]. Furthermore, general degradation of strength is often found in apparently flawless materials [5]. It is well known that material failure is usually preceded by some aspect of nonlinear mechanical behaviour before significant plastic deformation or material damage occurs [6]. It is acknowledged that the level of material degradation can be evaluated by measuring some aspect of acoustic nonlinearity. In particular for example one would expect that damage would affect the magnitude of higher-order harmonics, the presence of which is solely due to nonlinear effects. The relation between damage level and acoustic nonlinearity has been observed and demonstrated extensively in many configurations. The so-called finiteamplitude technique [7] has been proven to be useful for non-destructive detection of defects in ceramics [8], concrete structures [9,10], composites [11], as well as fatigue cracks in metals, such as steels, titanium, and aluminum alloys [12,13]. The induced nonlinearity, present at small strains, is attributed to e.g. Hertzian contact and other micro-structural effects such as internal stresses, micro-cracks, zero-volume disbonds, and usually precedes the main cracking mechanisms and the subsequent failure of the material. A common way of viewing these defects is to consider that the nonlinear acoustic response is due to an internal interface that separates the intact material and the inclusion. This contact interface can be either free (large pores, opened cracks), partially clamped (“clapping”mechanism between the opened/closed crack states), or ideally bonded, and is thought to be mostly responsible for the large ultrasonic nonlinear response of degraded materials [14]. Considerable experimental work has shown that cracks and imperfect interfaces can behave in a nonlinear fashion [15,16] and have thus opened up new opportunities to detect partially closed cracks that would be much more difficult to identify with conventional linear methods. Theoretically, acoustic nonlinearity manifests itself in higher order strain contributions to a macroscopic strain energy function (SEF) associated with the material, thus giving rise to nonlinear stress-strain relationships and effective nonlinear elastic moduli [17]. Of specific https://doi.org/10.1016/j.ultras.2018.10.009 Received 9 April 2018; Received in revised form 2 October 2018; Accepted 20 October 2018 ⁎ Corresponding author at: Department of Structural Mechanics, University of Granada, 18071 Granada, Spain. E-mail address: [email protected] (J. Melchor). Ultrasonics 93 (2019) 145–155 Available online 28 October 2018 0041-624X/ © 2019 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/BY/4.0/). T
interest is how these moduli depend on the micro-structure. In particular in the bone community, where the interest is on the dependence of these parameters on the presence of damage, usually assumed to be micro-cracks, Renaud et al. [4] state “However, little work has been done on the relationship between crack density and level of elastic nonlinearity” and in Muller et al. [3] “From empirical evidence it is clear that microcracks are responsible for the enhanced nonlinear response…we have no quantitative link between damage quantity and nonlinear response.”It therefore appears to be of importance to build theoretical models that can attempt to provide these links [18–20]. The problem of determining the effective linear elastic properties of an inhomogeneous material has been studied extensively [21–23].A popular approach in micro-mechanics is to characterize the heterogeneous medium via dispersions of inclusions or inhomogeneities [24] and a plethora of approximations have been proposed in order to approximate effective properties based on a spheroidal or ellipsoidal inclusion approximation thanks to the classical results of Eshelby [25,26]. Eshelby’s tensor also arises in convenient bounds on linear elastic properties of inhomogeneous media [27,28]. Extensions of these schemes to accommodate the case of cracked media in the linear (static) regime when the cracks are assumed open (traction free), have been carried out in numerous studies, see e.g. [29–31]. However, often overlooked is the effective low frequency dynamic response where cracks can be in either opened or closed states (or more complex loadings) depending upon whether, for example, the crack is in a compressive or tensile cycle of the propagating wave. Furthermore, the effect of nonlinear crack response can be significant. The extension of the homogenization procedure in order to incorporate nonlinear inhomogeneities, based on Eshelby’s theory, was developed by Giordano et al. [32], who obtained the bulk and shear moduli along with the nonlinear Landau coefficients of the overall material in terms of the elastic behaviour of the constituents and of their volume fractions, all in the context of small strain. Two types of nonlinear inclusions were investigated, spherical and parallel cylindrical inclusions, both of which were embedded into a linear homogeneous and isotropic matrix. In this context the material is considered to behave in a constitutively nonlinear manner under small strains (i.e. it is geometrically linear) [25,32,33,26]. In this work, a micro-mechanical model is proposed to relate the density of nonlinear micro-cracks to the macroscopic acoustic nonlinearity. To this end, the damaged material is idealized as a composite material: initially a dispersion of nonlinear isotropic spheroidal inclusions surrounded by a linear isotropic matrix. At the micro-scale, the clapping mechanism excited inside each micro-crack during ultrasonification is approximated by a Taylor expansion of the bilinear stress-strain constitutive law and the expansion is truncated at the quadratic term. This approximation is linked to the acoustic nonlinearity by rearranging the nonlinear Landau constitutive law. This approximation is convenient from an analytical viewpoint and permits progress to be made in terms of potential interpretation of microstructural modelling of damaged materials. It is, of course, important to note that there are multiple other possible sources of nonlinearity that we do not treat here. This includes hysteretic clapping, the crack tip plastic zone, partial closure and atomistic nonlinearities. [34–39]. Returning to the quadratic nonlinearity considered here as an approximation to nonlinear clapping, Eshelby’s tensor is employed within the Mori-Tanaka homogenization process [40], where the clapping micro-cracks are represented by effective nonlinear penny-shaped inclusions. The penny-shaped cracks are assumed to be aligned, as a consequence of a preferential fatigue load direction of the structure. The nonlinearity of the inclusions can therefore be described by the socalled Landau coefficients, which measure the deviation from linearity. Finally, the relationships between these Landau coefficients and the measurable acoustic nonlinearity in ultrasound are presented. It should be stressed that micro-mechanics can be employed in the context of linear and nonlinear acoustics described here because we are well into the so-called separation of scales regime, where propagating wavelengths are much larger than the defect or crack under consideration. Their response is thus quasi-static. For simplicity in this model we also neglect the nonlinear response in shear. The article proceeds as follows. In Section 2we introduce the framework of micro-mechanics and upscaling employed in order to determine the effective parameters associated with a cracked medium, beginning with the simple linear response of a cracked medium where penny-shaped cracks are modelled as traction free and ending with derivations of the effective nonlinear acoustic parameter associated with a damaged medium. A nonlinear clapping model associated with a single crack is introduced in Section 3and parameters associated with this model are then linked to an effective nonlinear inclusion model of the nonlinear crack response. These parameters are then fed into the general framework of effective acoustic nonlinearity in Section 4where effective properties are derived in terms of the third order elastic constant (associated with compressional nonlinearity), anisotropy coefficients and the density of microcracks. Finally, Section 5explores a specific configuration where the model can be employed to predict the effective nonlinear parameter associated with a damaged bone sample, although it should be stated that the methodology is potentially useful for a broad range of damaged media. We close with discussion in Section 6. 2. Micro-mechanics framework We model a damaged material in a similar manner to a composite material, as in e.g. [41–43]. In particular we are interested in the effect that damage, or more specifically micro-cracks, have on the effective mechanical properties of the medium and how this subsequently affects the nonlinear acoustic response of the material. We model these cracks as the limit of aligned spheroidal cavities as we shall explain shortly. Fig. 1. Outline of the considered medium: dispersion of nonlinear spheroidal inclusions in a linear isotropic host with distribution of microcracks defined by density = α ϕ δ /where ϕ is the volume fraction. J. Melchor et al. Ultrasonics 93 (2019) 145–155 146
Furthermore we shall consider these cracks to behave nonlinearly. Start by considering the case as depicted in Fig. 1 when a medium Ω has within it two elastic phases Ω 0 (the linear elastic host or matrix with elastic modulus tensor C 0and compliance tensor D0such that = C DI 00 where I is the fourth order identity tensor) and a collection of Ninclusions that comprise the phase Ω 1 . We do not restrict the elastic behaviour of the inclusion phase to be linear. We suppose that the inclusions are aligned spheroids with semi-axes ==aa ℓ 12 and a 3 in the xx, 1 2 and x 3 directions respectively, defining the aspect ratio =δa/ ℓ 3 so that <δ 1 ( >δ 1 ) for oblate (prolate) spheroids. Referring to Fig. 1, the volume of cracks vanishes in the strongly oblate limit of spheroidal cavities, i.e. →δ0 and so the effective contribution of the vanishing inclusion volume fraction has to be defined in this limit. The volume fraction ϕ of the inclusion phase is defined by =ϕΩ Ω 1 (1) where Ω denotes the volume of the domain Ω. The volume fraction ϕ clearly tends to zero in the limit →δ0 . This motivates the introduction of the density of microcracks == α ϕ δ Nπ(4 /3)ℓ Ω 3 (2) which is finite as →δ0 , and can also be interpreted as the volume fraction of the spherical inclusions that would have the same footprint or projection as the flat penny-shaped inclusions (of zero volume). Alternatively, if the penny-shaped inclusions were inflated to make them spherical, their volume fraction would be α . We employ the Mori-Tanaka method [40] in order to determine the effective behaviour of the medium, describing in succession first a brief summary of the linear elastic case and more importantly in detail the extension to incorporate nonlinear (clapping) effects. Let T be the Cauchy stress and E the linear strain. The average stress within the medium is straightforwardly determined as [32] =− +ϕϕ T CE CE T E ¯¯ ¯¯ {¯} 00111 (3) where the curly parentheses in f {·} denote an argument of the function fand where fr denotes the volume average over the rth phase, i.e. ∫ = f fdx 1 Ω{}Ω . r r r Ω r(4) Note that the general form for T E ¯{¯} 11 is retained since we have not yet specified the constitutive behaviour of the inclusion. 2.1. Micro-mechanics for linear elastic particulate media To employ the Mori-Tanaka method for the linear case, first assume that the inclusion is linear elastic, so that = T CE ¯¯ 11 1 and for an isolated inclusion Eshelby’s result is ==+ − ∞ EEISDCIE ¯(( )) ¯ 001 1 (5) where ∞ Edenotes the (uniform) strain in the far field and S is the (uniform) Eshelby tensor. Determining the volume average of the strain E ¯ in terms of E ¯ 1 then yields =∗ T CE ¯¯ , where =+ − +− + − ∗ − ϕϕϕ C CCCI ISDCI( )[ (1 )( ( ))] . 010 01 1 (6) The above approach summarizes the Mori-Tanaka method. Even though we have assumed a dilute dispersion of ellipsoids, the result (6) is feasible for non-dilute volume fractions in that it recovers the limit → ∗ C C 1 as →ϕ 1 . 2.2. Linear elasticity: open cracks in a homogeneous matrix Consider now the strongly oblate limit of the spheroidal cavity, i.e. →δ0 and →ϕ0together with = C0 1 . The latter means that Eshelby’s result becomes =− = − EISEFE() . 1100 (7) which is interpreted as an induced strain. Since =OE(1 ) 0 and the tensor F defined via =− = − OδFIS() (1/) 1 (see Appendix A), we have =OδE(1/ ) 1. Using this in the average strain expression =− +ϕϕEEE ¯(1 ) ¯¯ 0 1 , together with (3) when = T0 ¯ 1 yields = ∗∗ T CE ¯¯ where =− − + ∗− ϕϕϕ C CCF IF[(1 ) ] . 00 1 (8) Employing (2) means that (8) becomes =− − + ∗− αδαα C CCG IG[(1 ) ] , 00 1 (9) where we have defined =δ GF . Now take the limit →δ0 and introduce ⎜⎟ == ⎛ ⎝⎞ ⎠= →→ δOGFlim lim (1). δδ00 (10) The non-zero components of the transversely isotropic tensor are listed in (A.22) of Appendix A. Results are now obtained in terms of the modified volume fraction α , noting that is independent of α . The expression for ∗ C therefore becomes, in the penny-shaped crack limit [32] =− + ∗− αα C CI I([]). 01 (11) It should be noted that the above analysis requires only the input from the influence of a single crack feature, defined by its Eshelby tensor limit. A comparison of such methods with numerical methods associated with asymptotic homogenization in the antiplane elastic case, where cracks are arranged on a periodic lattice, was provided in [44]. We wish to understand how the above is extended to the case of nonlinear inclusions. We will do this shortly, but first as a precursor to this problem, let us consider how one can incorporate more complicated (linear) crack face traction effects. 2.3. Linear elasticity: allowing for crack face effects The mechanism for incorporating the effects of the crack face shall now be considered by scaling the inhomogeneity properties C1 on δ instead of taking it to be identically zero in the case of open cracks. Let us assume that as →=∼δδTCE CE0, 111 1 1 where =O C (1) 1. Using this in Eshelby’s result (5) we find that =−+δEISHE() 0 1 (12) =− + −− δISI ISHE()(()) 1 1 (13) where we have written =HSDC 0 1 , which we note is O (1) as →δ0 . Given that =− = − OδFIS() (1/) 1 the term involving H now contributes an “extra stress”associated with crack face effects. Once again using the average strain expression we find that =−+ + − αδ δ αδEF IHF FE[(1 )( ) ] ¯ 11 (14) and the averaged stress is =− +αδ αδ T CE C E C E ¯¯ . 001 121 (15) Note that the coefficient of the last term here is O δ() 2so that in the limit, this term will tend to zero since ∼OδE(1/ ) 1. The “extra stress” therefore arises purely due to the Eshelby result and not due to averaged stress. Therefore, using (14) in (15) and taking the penny-shaped crack limit →δ0 , we obtain =− ++ − αα T CI I H E ¯([ ]) ¯ 01 (16) noting that if we take → C 0 1 (so that =H0) we recover (11). As should be expected, the effect of a non-zero H has the effect of stiffening the material. In particular for example, in dynamics where a compressive wave will give rise to both open cracks (in tension) and closed cracks J. Melchor et al. Ultrasonics 93 (2019) 145–155 147
(in compression) the effective Young’s modulus cannot be that due to the open crack case considered above. Expression (16) is the correction to that result. 2.4. Micro-mechanics for nonlinear cracks Let us now assume that the stress-strain condition for the inclusion is nonlinear, taking the form =+ T TT LNL 111 associated with linear and nonlinear effects respectively, with the intention of modelling the behaviour of cracks. The form of the nonlinear term will be discussed shortly but since in general its leading form will be quadratic in the strain, we shall see that it needs an additional δ scaling in order to have an O (1) effect and remain bounded, i.e. this requires =δ T T NL N L 121, where ∼ T E() NL 11 2 so that scaling the linear term as in the previous section to accommodate linear crack face effects, =+δδ T CE T . NL 1112 1(17) Later on in Section 3we justify this scaling from a study of the local crack problem. It has been shown that for constitutive nonlinearity in the strain, the Eshelby result for spheroids holds and gives (with appropriate modifications to scalings as considered here) [32] =−+ +δδEISHESDT(( ) ) . NL 0120 1 (18) Using this in the average strain yields, after some work (and recalling that curly parentheses denote the argument of the function) =+ + + + − αδOδEIHG GFESDT E ¯() {}() NL 11 0 11(19) where we have retained only terms that will become important in the penny shaped limit and we note that we have conveniently put the δ inside the argument of the nonlinear stress term which is quadratic in its argument. Now we have to formally invert this expression which gives, =++ − − αEFIHG GEFUE[] ¯{¯} 11 (20) where U E{¯} refers to the first, quadratic nonlinear contribution to this equation, which it transpires, takes the form =+ + + + −− αα U E I HG G SD T G I HG G E{¯}( ) {( ) ¯}. NL 10 11 (21) Finally, using (20) in the average stress Eq. (3) and taking the penny-shaped crack limit, we find =− ++ − − ααα T CI I H E C E ¯([()]) ¯{¯} 010 (22) where =+ + + + −− ααEIH SDT IH E{¯}( ) {( ) ¯} . NL 10 11(23) Note once again that if we take the limit when nonlinear effects are negligible, →0, we recover the linear limit of the previous section and the result (16). Eq. (22) is therefore the extension of the homogenization procedure to the nonlinear (small strain) setting for penny shaped cracks. We now restrict the form of nonlinearity in order to identify a specific nonlinear constitutive parameter that can be used to identify damage via nonlinear ultrasonic testing. 3. Nonlinear crack clapping model In this section we describe the formulation of the nonlinear constitutive model of an individual micro-crack, which is later equated to an effective nonlinear inclusion for use in the micro-mechanical method described above. As opposed to linear crack analysis, which the literature treats as open (since closed cracks transmit compressional forces as if the material were intact), the nonlinear behaviour of cracks correctly models a range of states, either closed (for negative strains) or open (for positive strains). The clapping contact mechanism associated with a cyclic load exerted by oscillatory movement of the nonlinear ultrasonification behaves as follows: while the cracks tend to be closed at rest, once subject to the cyclic stress, cracks close during the compressional half-cycle, transmitting stress and establishing displacement continuity, whereas during crack opening under tension, the stress inside the crack vanishes and a displacement discontinuity arises across the crack face. 3.1. Nonlinear formulation This local clapping contact phenomenon gives rise to a nonlinear stress-strain relation at the defect [45]. Pecorari et al. [46] proposed a 1D clapping model for extension in the x 3 direction, where the crack face is in the xx 1 2 plane (referring to Fig. 1) with different elastic moduli for compression and tension, i.e. ⎜⎟ ⎜⎟ =⎛ ⎝−⎛ ⎝⎞ ⎠⎞ ⎠ THEE1{} Δ ccc 33 033 0 33 (24) where the superscript chere refers to the fact that this is intended to be the constitutive response of the crack. Later we will equate this to an effective nonlinear inclusion (with superscripts 1), thus relating the crack properties to an effective inclusion. Furthermore here, HE{} 33 is the Heaviside step function, 0 is the host Young’s modulus under compression, and Δ is its change under stress reversal to tension. We assume that the elastic modulus under tension is negligible and therefore = Δ 0. In fact this will be non-zero in reality and below we argue that for nonlinear effects to become important it should scale as δ 2 . The further assumption is that all other components of stress act linearly in the strain components. It transpires to be more simple to treat only volumetric components of stress and strain we shall describe in the next subsection, thus permitting us to obtain a one-dimensional compressional constitutive law that relates crack pressure =− p Ttr cc 1 3to crack volumetric strain =−vEtr cc 1 3(where E c is the induced crack strain) capturing the compressive or opening states of the crack behaviour in a single direction, and so we write = p Kv v3{} ccc (25) where K v{} c is the strain dependent bulk modulus. Hence, from Eq. (24), the bilinear stiffness of the proposed model with multiple microcracks is proposed in the form =− K vK Hv{} (1 {} ) cc 0 (26) where =+ K λμ2/ 3 00 0 is the linear elastic bulk modulus of the host material. In order to bypass the difficulty of engaging with a non-differenti- able function for the stress-strain law (via the extraction of a Taylor expansion of the Heaviside function) we approximate (26) by a logistic function with sharpness parameter : ⎜⎟ ≃⎛ ⎝−+⎞ ⎠ − K vK e {} 1 1 1 . c δv 0c2(27) When homogenizing, note that the assumption of common alignment of cracks is made, as well as negligible residual stresses that would be responsible for differences in the strain where the “kink”appears at the origin. These are averaged out via the smoothed bilinear form. The bilinear stiffness is now approximated by a Taylor expansion of (27) for small δ , i.e. ⎜⎟ ≃⎛ ⎝−+⎞ ⎠ K vK δv Ov{} 1 24 (( ) ) . ccc 0 22 (28) The parameter is a parameter that conveys nonlinearity, in this case it is associated with the crack under tension and is required to be measured via experiment. The scaling δ 2 is such that the nonlinear term can contribute to the homogenized properties as described in Section 2.4. One could also consider an O δ( ) term if one wished (adding such a J. Melchor et al. Ultrasonics 93 (2019) 145–155 148
term in the exponent of the exponential function in (27)) in order to take into account linear crack face effects, as discussed in Section 2.3 but here our interest resides in nonlinear effects only. In Fig. 2 we plot the different approximations to the bilinear response, taking =×δ7.2 10 2 4 , a value which is discussed further in Section 5. The result (28) essentially says that the first linear approximation contains half open (zero modulus) and half closed cracks (intact modulus). This average yields an effective bulk modulus of the inclusion of K /2 0 , which coincides with the first linear tangent term of the Taylor expansion. We now write the crack response in tensor form. Since any second order isotropic tensor (stress or strain) can be split into volumetric (scalar) and deviatoric (tensor) parts, the constitutive equation can be rearranged as particular cases of the following general form ⏟ =− + =−pp T IT T,1 3tr . cc D ccc 2 volumetric deviatoric (29) where I 2 is the second order identity tensor with components =δI ( ) ij i j 2 . The strain is also decomposed similarly, =− + =−vvEID E,1 3tr . cc cc c 2(30) The linear elastic dependency is enriched with quadratic terms, following the series expansion concept put forth by Landau [47]. Only the volumetric part is detailed in terms of a nonlinearity parameter β due to the scalar nature of the volumetric strain v. Further since experimentally only compressional ultrasonic waves will probe the structure, i.e. =D0 c, and the nonlinear transverse terms are considered negligible, denoted as “…” in the following, we write ⏟ −=− + =… pKvβKv μTD 39(), 2. cccccc D cc 1 2 2 Linear Nonlinear (31) where K cis the linear elastic bulk modulus associated with the crack. The definition of the compressional nonlinearity stems from the Taylor expansion of pressure p cin Eq. (25) with respect to volumetric strain vc , where the order zero term is zero, the first order term is linear elastic, being proportional to vc and the second order (nonlinear) term is proportional to v() c 1 2 2 . The parameter β cis defined to capture the volumetric constitutive nonlinearity as a consequence of the clapping nonlinearity associated with the change of volume during closing and opening. Putting the pressure relation in (31) in the form (25) we have therefore =⎛ ⎝− ⎞ ⎠ K vK βv{} 1 3 2 ccc (32) and the linear and nonlinear terms can be identified by equating this with (28) giving = K K 1 2 , c0(33) and = β δ 1 3. c2 (34) It remains now to formulate the tensorial nonlinear isotropic response of an inclusion phase, equate this with the crack response above and use this in the context of micro-mechanics. 3.2. Nonlinear Landau coefficients of inclusions and relations to the crack nonlinearity The constitutive definition of Cauchy stress in an inclusion T1 is separated into two components in terms of a linear T L 1 and nonlinear T N L 1response respectively, as follows, =+ T TT , LNL 111 (35) reducing to = T T L 11for linear inclusions. The nonlinear constitutive response of the crack is assumed to be of the second order form established by Landau et al. [47], valid for a three-dimensional continuum, see e.g. [48,49], which for an isotropic medium is =+ + + T EE EIEE EI() () (tr(()) 2tr()) (tr) . NL 11112 112 211 1122 (36) The penny-crack limit ensures that the macroscopic response is transversely isotropic for aligned cracks. λ and μ are the Lamé constants and ,, 11 1 are the Landau coefficients, where the following approximation has been applied, since the linear constants are negligible Fig. 2. Illustration of the exact bilinear constitutive law, its approximation via the logistic function and associated Taylor expansions, employing the fitting parameter combination =×δ7.2 10 2 4 . J. Melchor et al. Ultrasonics 93 (2019) 145–155 149
when compared to the nonlinear ones, +≃ +−≃ −≃ μ λμ λ 4, , . 111 11 11 11 1 (37) In order to relate to the nonlinear crack form, combine Eqs. (29)–(31). Furthermore from (33) write == K KK/ 2 c10 and recalling that =D0 cwe have =− −KβK T EI E I 1 2tr 4(tr ) . c 1012 0122(38) Compared to the general form (36) one establishes that under the present assumptions, the nonlinear properties are ===−βK 0, 0, 4 c 111 0 (39) and therefore = T EEI() (tr) . NL 111122(40) With (34) we have ==− =− βK δK 412 cc 1 020 (41) or rather with the scaling of δ 2 we may re-write (35) as =+δ T TT , LNL 1121(42) with = T EI(tr ) . NL 1 1122(43) where =− K 12 10 (44) which provides the link between the parameter associated with the local single crack problem and the effective inclusion that represents the crack. 4. Effective acoustic nonlinearity Given that we now have a model for the nonlinear behaviour of the cracks and specifically a model for the effective inclusion properties that represent the nonlinear behaviour of an isolated crack, let us use this in order to determine the effective nonlinear behaviour of the cracked material. For conciseness and computational ease we introduce the notation =+ +− α X IH[( ) ] 1 (45) together with = Y Xand = Z YSD0which we note both depend on α as well as the effective linear elastic moduli defined in (6) and written in the current notation as =− ∗α C CI Y( ) 0. Referring to (23) and (40)–(44) we can then write = = EZTYE YE Z I {¯}{ ¯} (tr( ¯)) : . NL 1 122(46) The total average stress is written =− ∗ α T CE C YE Z I ¯¯ (tr( ¯)) : . 102 2 (47) Importantly note that the same non-zero components of are also non-zero in X Y, and Z . This simplifies the analysis significantly. Our investigation of nonlinearity focuses on a compressional stress wave propagating in the x 3 direction, with zero lateral stresses. The strains =≠ E EE 11 22 33 and all shear strains are zero. We investigate the propagation of longitudinal, compressional waves in the x 3 direction, i.e. the only non-zero stress is T 3 3 and the contributions to this stress are therefore from the Z kl33 terms. Given that ==YY0 kk11 ℓ 22 ℓ ,it is straightforward to show that ==− ∗ E EνE A22 11 33 (48) where ∗ ν A is known as the (effective) axial Poisson’s ratio as determined from the effective linear elastic modulus tensor via =+ ∗∗ ∗∗ νC CC . A1133 1111 1122 (49) The equation for the tensile/compressive longitudinal stress is rather more complicated thanks to the non-zero components of the tensors introduced above. First note that =++ =− ∗ YE YE YE YνYE YEtr( ¯) (2) A 3311 11 3322 22 3333 33 3333 3311 33 (50) and =+++ + ≃+ CZ Z Z C Z Z CZ Z CZ I(:) ( ) (2 ) (2 ). 0233 3311 01111 1122 1133 3333 03311 3333 3333 03311 3333 (51) Then, eliminating E ¯ 1 1 via (48) we find =− =− ∗∗∗ ∗∗ TEβE βE E(1 ) 33 33 33 2 33 33 (52) where ∗ β defines the effective nonlinear parameter that characterizes the compressional nonlinearity in the x 3 direction and the effective linear elastic Young’s modulus is =− ∗∗∗ ∗ CCν(2). A 3333 3311 (53) The effective nonlinear parameter ∗ β takes the form ⎜ ⎟ =− ⎛ ⎝+ ⎞ ⎠ ∗∗∗ β αYνYCZZ(2)2 A1 3333 3311 23333 03311 3333 (54) where 1 is the Landau parameter of the inclusion that represents the effective nonlinear response of the crack that was derived in (44). 5. Numerical validation Let us now turn to a specific example that allows us to determine the effective nonlinearity of the medium in question and in particular to determine the relationship between the effective acoustic nonlinearity ∗ β , the density of microcracks α and the nonlinearity of the inclusion β c. Note that the nonlinear parameter β cdepends on associated with the crack under tension and the scaling δ 2 , which can be quantified experimentally. Contractions and inversions of transversely isotropic tensors within the tensors X Y, and Z are computed using Matlab (The MathWorks, Inc., Natick, Massachusetts, United States). Let us consider a specific model example where a cancellous bone sample is immersed in water and is interrogated by nonlinear ultrasound at a given central frequency f. The incoming pressure p w in the water at the back of the sample is registered by a needle hydrophone. The water displacement U w can be obtained as, =Up ρc π f 2 ww ww(55) where ρ w and c w are the density of water and speed of sound, respectively. Considering that the water gap between the specimen and the hydrophone is small (that is, the attenuation in water will be negligible), the displacement of the particles in the specimen is obtained as =UU T sw sw (56) where T sw denotes the transmission coefficient from bone to water, defined as, =+ TZ ZZ 2 sw w sw (57) J. Melchor et al. Ultrasonics 93 (2019) 145–155 150
where == Z ρc i w s,, iii is the impedance of a material i. The displacement field and associated longitudinal strain in the sample is, as a first approximation, of the form, =− = −UxtUkxωtExtUk kxωt(, ) sin( ), (, ) cos( ) ss ss s33 (58) where =kωc/ ss is the wave number. The maximal strain is obtained when −=kx ωtcos( ) 1 s , that is =− =vEUk css 1 333 1 3.Table 1 summarizes the values of the obtained variables UU, w s together with relevant parameters that are employed, for a measured pressure = p 85 w [kPa]. Note that water and bone values for densities, velocities, Lamé constants and displacements have been introduced in order to deduce a consistent and realistic validation of the nonlinear parameters. Results obtained in this section are obtained by implementing the theory developed above with the relevant parameters in Table 1. In particular we calculate the effective Young’s modulus ∗ from (53) and the effective nonlinear parameter ∗ β from (54) with the former as a function of the crack density parameter α and the latter as a function of α as well as the crack aspect ratio δ and the Poisson ratio ν0. Figs. 3 and 4 illustrate the dependence of ∗ and ∗ β (respectively) on the crack density parameter α . Plots have been provided for four different host Poisson ratios noting that for bone ≈ν0. 4 0. What is particularly striking is the variation in properties with α . The percentage change in effective Young’s modulus for an α variation over two orders of magnitude is barely noticeable. Given that the effective density of the medium also remains very close to the host medium in this regime the change in compressional wave speed will be extremely small. In contrast the effective compressional nonlinearity parameter ∗ β changes significantly over the same range of α values. This prediction of ∗ β falls in the range of values measured for various types of bone [4] and further justifies the use of nonlinear acoustics as a potential diagnostic tool to detect early stage failure in materials. In Fig. 5 the parameter ∗ β is plotted as a function of the crack aspect ratio δ . Variation in this parameter is very small in the parameter regime << −− δ 1 010 12 2. This illustrates that the parameter is fairly stable with respect to crack aspect ratios in realistic aspect ratio parameter ranges. Finally, Fig. 6 depicts the dependency of the effective nonlinear acoustic parameter on Poisson’s ratio, noting that the maximum of ∗ β is located around =ν0.425 . This maximal value is located in a region ideal for the case of bone where ≈ν0. 4 0. 6. Discussion A nonlinear micro-mechanical approach has been proposed that relates the microscopic properties of a distribution of clapping microcracks in damaged materials to the macroscopic measurable acoustic nonlinearity. A 1D contact clapping mechanism inside each micro-crack is hypothesized to be responsible for a component of the quadratic nonlinearity. This relationship is formulated by establishing a bilinear clapping constitutive law, which is subsequently approximated by a Taylor expansion, from which the second order constitutive nonlinearity stems. The simplifying assumption to restrict the effect to second order compressional nonlinearity can be questioned in terms of capturing the full nonlinear dynamics of a clapping crack, and would require further extension in future work. However, there are practical reasons for incorporating such second order behaviour, which are related to the generation of second harmonics. These are measurable with ultrasonic equipment and could potentially be employed to inspect structural functionality and damage. It should be clarified that other possible sources of nonlinearity are not treated in this work, such as hysteretic clapping, crack tip plastic zone, partial closure, or atomistic nonlinearities. Their formulations therefore remain open. The distributed micro-cracks are treated as individual effective penny-shaped inclusions behaving in the manner formulated above with associated effective properties. These nonlinear inclusions are considered as embedded in a uniform host medium and the overall homogenized response is determined via a nonlinear Mori-Tanaka scheme following Giordano’s recent work on the extension of Eshelby’s result to small -strain nonlinearity. The effective nonlinear response of the crack is defined by its aspect ratio δ , which is interpreted as a Table 1 Elastic parameters of the crack/effective inclusion. Host density and stiffness properties have been taken from typical bone sample values with =× = E Pa ν14 10 [ ], 0. 4 090 [50] Property Value Displacement in water U w 13.5281 [nm] Displacement in sample U s 36.8009 [nm] Frequency f666.67 [kHz] Speed of sound in water cw1500 [m/s] Speed of sound in sample cs3700 [m/s] Lamé modulus λ1 × 1 .15 101 1 [Pa] Shear modulus μ 1 ×2.349 10 9 [Pa] Density ρ 1 × 1 10 3 [kg/m 3 ] Scaling parameter δ × − 1 10 5 – Sharpness parameter ×7.2 1014 – Nonlinearity of inclusion β c ×2.4003 10 4 – Landau coefficient of inclusion 1 ×22 10 1 3 [Pa] Fig. 3. Illustrating the variation in the linear elastic Young’s modulus of the cracked medium ∗ as a function of the crack density parameter α ,asdefined by (53). The four curves relate to different host medium Poisson ratios. In particular it should be noted that two orders of magnitude change in α leads to a very small change in the predicted ∗ . J. Melchor et al. Ultrasonics 93 (2019) 145–155 151
geometric parameter and the nonlinear parameter , which is interpreted as a material parameter and links to the Landau nonlinearity. Relationships between the measurable acoustic nonlinearity and the Landau-type nonlinearity required by the homogenization scheme are thus proposed. For this purpose, the proposed decomposition of stress and strain tensor into compressional and deviatoric parts plays a key role in redefining several possible acoustic nonlinearities in a convenient way. It should be noted that the model incorporates only a Fig. 4. Illustrating the variation in the effective compressive nonlinearity coefficient of the cracked medium ∗ β as a function of the crack density parameter α ,as defined by (54). The four curves relate to different host medium Poisson ratios. Here it should be noted that two orders of magnitude change in α leads to two orders of magnitude change in ∗ β . This is in stark contrast to the variation in ∗ with α as noted in Fig. 3. Fig. 5. Illustrating the variation in the effective compressive nonlinearity coefficient of the cracked medium ∗ β as a function of the crack aspect ratio δ . It is noted that this parameter is relatively insensitive to variations in δ for << −− δ 1 010 12 2 . Fig. 6. Illustrating the variation in the effective compressive nonlinearity coefficient of the cracked medium ∗ β as a function of the host Poisson ratio ν 0 . It is noted that for bone ≈ν0. 4 0, meaning that this is close to where ∗ β reaches a maximum. J. Melchor et al. Ultrasonics 93 (2019) 145–155 152
small number of parameters, which is always beneficial in terms of linkage to experimental data. The assumption that penny-shaped inclusions are aligned is justified by the fact that fatigue cracks produced by a preferentially-oriented stress appear to be aligned. However, the case of randomly oriented micro-cracks can be developed in future work, by employing the formulation provided in the present paper. Acknowledgments The authors acknowledge the Spanish Ministerio de Economía y Competitividad for project DPI2014-51870-R and Junta de Andalucía for projects P11-CTS-8089 and GGI3000IDIB. Melchor is grateful to the University of Manchester for funding via the Engineering and Physical Science Research Council (EPSRC) grant reference EP/I01912X/1. Parnell is grateful to the EPSRC for his research fellowship (EP/ L018039/1). Appendix A. The Eshelby tensor, associated tensors and their strongly oblate limits TI tensors can be conveniently defined and manipulated by using the Hill basis tensors n() whose components are defined as ===δδ δδ 1 2ΘΘ,Θ,Θ , ijkl ij kl ijkl ij k l ijkl kl i j (1) (2) 33 (3) 33 (A.1) ⎜ ⎟ == ⎛ ⎝+− ⎞ ⎠ δδδ δ,1 2ΘΘ ΘΘ ΘΘ ijkl ijkl ijkl ik lj il kj ij kl (4) 33 33 (5) (A.2) ⎜⎟ =⎛ ⎝+++⎞ ⎠ δδ δ δ δδ δ δ 1 2ΘΘΘΘ , ijkl ik l j il k j jk l i jl k i (6) 33 33 33 33 (A.3) with =−δδδΘij ij i j33 so that the xx 1 2 plane is the plane of isotropy. A fourth order TI tensor X say, is conveniently written down in terms of the TI basis as ∑ ==X X n nn 1 6 () (A.4) Further, we find that =+ = =XX X XX XX,, , 11111 1122 21133 33311 (A.5) ==−=XX XX X X X,,2 43333 51111 1122 6131 3 (A.6) The minor (but not major) symmetries hold and furthermore we note that =−XXX()/ 2 1212 1111 1122 . The inverse − X 1 of a transversely isotropic tensor X is straightforwardly determined as ∑ = −= X X n nn1 1 6 ( ) (A.7) where ==−=−XX X X X X/Δ, /Δ, /Δ , 1 4 2 2 3 3 (A.8) ===XX X XX X/Δ, 1/ , 1/ 4 1 5 5 6 6 (A.9) and =−XX XX Δ 2( ) 14 23 . For a spheroid, the non-zero components of the Eshelby tensor are =−+ − + − −− SδLδLLνδLν δν 1 8 3134 8 8 (1)(1) , 1111 22 020 20 (A.10) =−+− + − −− SδLδLLνδ Lν δν 1 8 48 8 (1)(1) , 1122 22 020 20(A.11) =−−++ − −− SδL δ L Lνδ Lν δν 1 2 222 (1)(1) , 1133 22 020 20(A.12) =−+ − − + + − −− SL δ δ L Lν δ ν Lν δ Lν δν 1 2 22 24 4 (1)(1) , 3311 22 0200 20 20(A.13) =−++ −+ −− + −− Sδ δLLνδ ν Lνδ Lν δν 214 2 2 (1)(1) , 3333 220200 20 20(A.14) =− +−+ − − + −− SδL L Lνδ Lν νδ ν δν 1 2 21 (1)(1) . 1313 20200 20 20(A.15) where J. Melchor et al. Ultrasonics 93 (2019) 145–155 153